Are You suprised ?

Birthday

LSK

Test Report

Golden Champion Industrial Ltd KKYR3202 Smart Roller Shade Remote Control 2A8U6-KKYR3202 2A8U6KKYR3202 kkyr3202

PDF Viewing Options

Not Your Device? Search For Manuals or Datasheets below:


File Info : application/pdf, 21 Pages, 771.03KB

Document DEVICE REPORTGetApplicationAttachment.html?id=6240330
Golden Champion Industrial Ltd

TEST REPORT

SCOPE OF WORK EMC TESTING­KKYR3202

REPORT NUMBER 220610072GZU-001

ISSUE DATE

[REVISED DATE]

17-November-2022 [--------------------]

PAGES
21

DOCUMENT CONTROL NUMBER FCC part 15.231-e © 2017 INTERTEK

TEST REPORT

Room 02, & 101/E201/E301/ E401/E501/E601/E701/E801 of Room 01 1-8/F., No. 7-2. Caipin Road, Science City, GETDD, Guangzhou, Guangdong, China Telephone: +86 20 8213 9688 Facsimile: +86 20 3205 7538 www.intertek.com.cn

Applicant Name & Address Manufacturing Site Intertek Report No: FCC ID:

: Golden Champion Industrial Ltd No.56, Lane 2, Yong Le Street, Kang, Kaohsiung, Taiwan
: Same as applicant 220610072GZU-001 2A8U6-KKYR3202

Test standards

CFR 47, FCC PART 15 Subpart C: 2020 section 15.231

Sample Description

Product Model No. Electrical Rating Serial No. Date Received Date Test Conducted

: Remote Control : KKYR3202 : 1.5VDC*2 : Not Labeled : 10 June 2022 : 26 October 2022 to 31 October 2022

Prepared and Checked By

Approved By:

Elena Lei Engineer

Dean Liu Project Engineer

This report is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this report. Only the Client is authorized to permit copying or distribution of this report and then only in its entirety. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test results in this report are relevant only to the sample tested. This report by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program.

Intertek Testing Services Shenzhen Ltd. Guangzhou Branch

Room 02, & 101/E201/E301/E401/E501/E601/E701/E801 of Room 01 1-8/F., No. 7-2. Caipin Road, Science City, GETDD, Guangzhou,

Guangdong, China

Version: 03 September 2021

Page 2 of 21

FCC Part 15.231-e

Intertek Report No.: 220610072GZU-001
TEST REPORT
CONTENT
TESTREPORT........................................................................................................................... 1 CONTENT ............................................................................................................................. 3 1.0 TEST RESULT SUMMARY ............................................................................................ 4 2.0 GENERAL DESCRIPTION.............................................................................................. 5
2.1 PRODUCT DESCRIPTION ........................................................................................................5 2.2 RELATED SUBMITTAL(S) GRANTS ............................................................................................5 2.3 TEST METHODOLOGY ...........................................................................................................5 2.4 TEST FACILITY......................................................................................................................5 3.0 SYSTEM TEST CONFIGURATION.................................................................................. 6 3.1 JUSTIFICATION.....................................................................................................................6 3.2 EUT EXERCISING SOFTWARE..................................................................................................7 3.3 SPECIAL ACCESSORIES...........................................................................................................7 3.4 MEASUREMENT UNCERTAINTY...............................................................................................7 3.5 EQUIPMENT MODIFICATION ..................................................................................................8 3.6 SUPPORT EQUIPMENT LIST AND DESCRIPTION ..........................................................................8 4.0 MEASUREMENT RESULTS........................................................................................... 9 4.1 ANTENNA REQUIREMENT ......................................................................................................9 4.2 RADIATED EMISSIONS.........................................................................................................10 4.3 OCCUPIED BANDWIDTH ......................................................................................................18 4.4 DWELL TIME .....................................................................................................................19 4.5 CONDUCTED EMISSION TEST................................................................................................20 5.0 TEST EQUIPMENT LIST ............................................................................................. 21

Version: 03 September 2021

Page 3 of 21

FCC Part 15.231-e

Intertek Report No.: 220610072GZU-001

TEST REPORT

1.0 TEST RESULT SUMMARY

Test Item

Test Requirement Test Method

Radiated Emission

FCC PART 15 section 15.231(b)

ANSI C 63.10: Clause 6.4, 6.5 and 6.6

Occupied Bandwidth

FCC PART 15 section 15.231(c)

ANSI C 63.10: Clause 6.9

Dwell Time

FCC PART 15 section 15.231(a)

FCC PART 15: Section 15.231(a)

Remark: N/A: not applicable. Refer to the relative section for the details. EUT: In this whole report EUT means Equipment Under Test. Tx: In this whole report Tx (or tx) means Transmitter. Rx: In this whole report Rx (or rx) means Receiver. RF: In this whole report RF means Radio Frequency. ANSI C63.10: the detail version is ANSI C63.10:2013 in the whole report.

Result PASS PASS PASS

Version: 03 September 2021

Page 4 of 21

FCC Part 15.231-e

Intertek Report No.: 220610072GZU-001

TEST REPORT

2.0 General Description 2.1 Product Description

Operating Frequency Type of Modulation: Number of Channels Channel Separation: Antenna Type Power Supply: Power cord: Function:

433.92MHz ASK 1 Channel N/A Internal DC 3V N/A Wireless heater with 433.92MHz as carrier.

2.2 Related Submittal(s) Grants
This is an application for certification of: DSC - Part 15 Security/Remote Control Transmitter.
Remaining portions are subject to the following procedures: 1. Receiver portion: FCC 15B SDOC.

2.3 Test Methodology
Radiated emission measurements were performed according to the procedures in ANSI C63.10. Radiated emission measurement was performed in semi-anechoic chamber and conducted emission measurement was performed in shield room. For radiated emission measurement, preliminary scans and final tests were performed in the semi-anechoic chamber to determine the worst case modes. All radiated tests were performed at an antenna to EUT distance of 3 meters, unless stated otherwise.

2.4 Test Facility
All tests were performed at: Intertek Testing Services Shenzhen Ltd. Guangzhou Branch Room102/104, No 203, KeZhu Road, Science City, GETDD Guangzhou, China Except Conducted Emissions was performed at: Room 02, & 101/E201/E301/E401/E501/E601/E701/E801 of Room 01 1-8/F., No. 7-2. Caipin Road, Science City, GETDD, Guangzhou, Guangdong, China

Version: 03 September 2021

Page 5 of 21

FCC Part 15.231-e

Intertek Report No.: 220610072GZU-001

TEST REPORT
A2LA Certificate Number 0078.10 Intertek Testing Services Shenzhen Ltd. Guangzhou Branch is accredited by A2LA and Listed in FCC website. FCC accredited test labs may perform both Certification testing under Parts 15 and 18 and Declaration of Conformity testing.
3.0 System Test Configuration
3.1 Justification

For emissions testing, the equipment under test (EUT) setup to transmit continuously to simplify the measurement methodology. Care was taken to ensure proper power supply voltages during testing. During testing, It was powered by DC3V supply.

When below 30MHz, the measurement antenna was positioned with its plane perpendicular to the ground at the specified distance. When perpendicular to the ground plane, the lowest height of the magnetic antenna was 1 m above the ground and was positioned at 3m distance from the EUT. During testing the loop antenna was rotated about its vertical axis for maximum response at each azimuth and also investigated with the loop positioned in the horizontal plane. For each measurement antenna alignment, the EUT shall be rotated through 0° to 360° on a turntable. When above 30MHz, the antenna height and polarization are varied during the search for maximum signal level. The antenna height is varied from 1 to 4 meters. Radiated emissions are taken at three meters unless the signal level is too low for measurement at that distance. If necessary, a pre-amplifier is used and/or the test is conducted at a closer distance.
All readings are extrapolated back to the equivalent three meter reading using inverse scaling with distance. The spurious emissions more than 20 dB below the permissible value are not reported.
For an intentional radiator, the spectrum shall be investigated from the lowest radio frequency signal generated in the device, without going below 9 kHz, up to at least the frequency shown in the following table:
Frequency range of radiated emission measurements

Lowest frequency generated in the device
9 kHz to below 10 GHz At or above 10 GHz to below
30 GHz
At or above 30 GHz

Upper frequency range of measurement
10th harmonic of highest fundamental frequency or to 40 GHz, whichever is lower 5th harmonic of highest fundamental frequency or to 100 GHz, whichever is lower 5th harmonic of highest fundamental frequency or to 200 GHz, whichever is lower, unless otherwise specified

Version: 03 September 2021

Page 6 of 21

FCC Part 15.231-e

Intertek Report No.: 220610072GZU-001

TEST REPORT

Number of fundamental frequencies to be tested in EUT transmit band

Frequency range in which device

Number of

Location in frequency

operates

frequencies

range of operation

1 MHz or less

1

Middle

1 MHz to 10 MHz

2

1 near top and 1 near bottom

1 near top, 1 near

More than 10 MHz

3

middle and 1 near

bottom

3.2 EUT Exercising Software N/A 3.3 Special Accessories No special accessories used.

3.4 Measurement Uncertainty

No. Item

Measurement Uncertainty

20 dB Bandwidth

1

6dB Bandwidth

2.3%

99% Bandwidth

2

Radiated Emissions

4.62dB (25 MHz-1 GHz) 4.67dB (1 GHz-18 GHz) 4.76dB (18GZH-26GHz)

3

Conducted Emissions at Mains Terminals 2.51dB

4

Time

1.2%

The measurement uncertainty describes the overall uncertainty of the given measured value during the operation of the EUT. Measurement uncertainty is calculated in accordance with ETSI TR 100 028-2001. The measurement uncertainty is given with a confidence of 95%, k=2.

When determining of the test conclusion, the Measurement Uncertainty of test has been considered.

Uncertainty and Compliance ­ Unless the standard specifically states that measured values are to be extended by the measurement uncertainty in determining compliance, all compliance determinations are based on the actual measured value

Version: 03 September 2021

Page 7 of 21

FCC Part 15.231-e

Intertek Report No.: 220610072GZU-001
TEST REPORT 3.5 Equipment Modification
Any modifications installed previous to testing by Golden Champion Industrial Ltd will be incorporated in each production model sold / leased in the United States. No modifications were installed by Intertek Testing Services Shenzhen Ltd. Guangzhou Branch.
3.6 Support Equipment List and Description
The client made a continuous transmit sample for test, in actual use the product has duty cycle (detail information can refer to page 14-16).

Version: 03 September 2021

Page 8 of 21

FCC Part 15.231-e

TEST REPORT

Intertek Report No.: 220610072GZU-001

4.0 Measurement Results
4.1 Antenna Requirement
Standard requirement: 15.203 requirement: For intentional device. According to 15.203. an intentional radiator shall be designed to Ensure that no antenna other than that furnished by the responsible party shall be used with the device. EUT Antenna The antenna is an integral antenna and no consideration of replacement.

Size of antenna:

Version: 03 September 2021

Page 9 of 21

FCC Part 15.231-e

TEST REPORT

Intertek Report No.: 220610072GZU-001

4.2 Radiated Emissions

Test Requirement:

FCC Part 15 C section 15.231(b)

Test Method:

ANSI C63.10: Clause 6.4, 6.5 and 6.6

Measurement Distance: Test Status: Test site:

3 m (Semi-Anechoic Chamber) Test the transmitter in continuous transmitting mode. Measurement Distance: 3m (Semi-Anechoic Chamber)

Limit:

The field strength of emissions from intentional radiators operated under this Section shall not exceed the following:

Fundamental Frequency MHz

Field Strength of Fundamental (dBµV/m @ 3 m)

Field Strength of Harmonics and Spurious Emissions (dBµV/m @ 3
m)

40.66 to 40.70

67.04

47.04

70 to 130

61.94

41.94

130 to 174

61.94 to 71.48**

41.94 to 51.48**

174 to 260

71.48

51.48

260 to 470

71.48 to 81.94**

51.48 to 61.94**

Above 470

81.94

61.94

** linear interpolations
[Where F is the frequency in MHz, the formulas for calculating the maximum permitted fundamental field strengths are as follows: for the band 130-174 MHz, uV/m at 3 meters = 56.81818(F) - 6136.3636; for the band 260-470 MHz, uV/m at 3 meters = 41.6667(F) 7083.3333. The maximum permitted unwanted emission level is 20 dB below the maximum permitted fundamental level.]
The fundamental frequency of the EUT is 433.92 MHz
The limit for average or QP field strength dBuv/m for the fundamental emission= 80.8 dBµV/m
No fundamental is allowed in the restricted bands.
The limit for average field strength dBuv/m for the spurious emission=60.8 dBuV/m. Spurious Emissions do not fall in the restricted bands must be less than 60.8 dBuV/m or limits shown in Section 15.209, whichever limit permits a higher field strength.
Spurious Emissions appear within the restricted bands shall not exceed the limits shown in Section 15.209.
Field Strength Calculation: The field strength is calculated by adding the reading on the Spectrum Analyzer to the factors associated with preamplifiers (if any), antennas, cables, pulse desensitization and average factors (when specified limit is in average and measurements are made with peak detectors). A sample calculation is included below: FS = RA + AF + CF - AG + PD + AV FS = RA + Correct Factor + AV

Version: 03 September 2021

Page 10 of 21

FCC Part 15.231-e

TEST REPORT Where:

Intertek Report No.: 220610072GZU-001
FS = Field Strength in dBµV/m
RA = Receiver Amplitude (including preamplifier) in dBµV AF = Antenna Factor in dB/m CF = Cable Attenuation Factor in dB AG = Amplifier Gain in dB PD = Pulse Desensitization in dB AV = Average Factor in ­dB Correct Factor = AF + CF ­ AG + PD
In the radiated emission table which follows, the reading shown on the data table may reflect the preamplifier gain. An example of the calculations, where the reading does not reflect the preamplifier gain, follows: FS = RA + AF + CF - AG + PD + AV Assume a receiver reading of 62.0 dBµV is obtained. The antenna factor of 7.4 dB/m and cable factor of 1.6 dB is added. The amplifier gain of 29 dB is subtracted. The pulse desensitization factor of the spectrum analyzer was 0 dB, and the resultant average factor was -10 dB. The net field strength for comparison to the appropriate emission limit is 32 dBµV/m. RA = 62.0 dBµV AF = 7.4 dB/m CF = 1.6 dB AG = 29.0 dB PD = 0 dB AV = -10 dB Correct Factor = 7.4 + 1.6 ­ 29.0 + 0 = -20 dB/m FS = 62 + (-20) + (-10) = 32 dBµV/m

Version: 03 September 2021

Page 11 of 21

FCC Part 15.231-e

TEST REPORT
Test Configuration: 1) 9 kHz to 30 MHz emissions:

Intertek Report No.: 220610072GZU-001

2) 30 MHz to 1 GHz emissions:

Version: 03 September 2021

Page 12 of 21

FCC Part 15.231-e

TEST REPORT 3) 1 GHz to 40 GHz emissions:

Intertek Report No.: 220610072GZU-001

Test Procedure:
1) 9 kHz to 30 MHz emissions:
For testing performed with the loop antenna. The lowest height of the loop was positioned 1 m above the ground and positioned with its plane vertical at the special distance from the EUT. During testing the loop was rotated about its vertical axis for maximum response at each azimuth and also investigated with the loop positioned in the horizontal plane.
2) 30 MHz to 1 GHz emissions:
For testing performed with the bi-log type antenna. The measurement is performed with the EUT rotated 360º, the antenna height scanned between 1m and 4m, and the antenna rotated to repeat the measurement for both the horizontal and vertical antenna polarizations.
3) 1 GHz to 40 GHz emissions:
Test site with RF absorbing material covering the ground plane that met the site validation criterion called out in CISPR 16-1-4:2010 was used to perform radiated emission test above 1 GHz.
For testing performed with the horn antenna. The measurement is performed with the EUT rotated 360º, the antenna height scanned between 1m and 4m, and the antenna rotated to repeat the measurement for both the horizontal and vertical antenna polarizations.

Detector:
For Peak and Quasi-Peak value: RBW = 1 MHz for f  1 GHz, 200 Hz for 9 kHz to 150 kHz 9 kHz for 150 kHz to 30 MHz 120 kHz for 30 MHz to 1GHz

Version: 03 September 2021

Page 13 of 21

FCC Part 15.231-e

Intertek Report No.: 220610072GZU-001
TEST REPORT
VBW  RBW Sweep = auto Detector function = peak for f  1 GHz, QP for f < 1 GHz Trace = max hold For AV value: Average = Peak value + 20log (Duty cycle)
The average correction factor is computed by analyzing the on time in 100ms over one complete pulse train. Analysis of the remote transmitter on time in one complete pulse train, therefore the average value of fundamental frequency is: Average = Peak value + 20log (Duty cycle), where the duty factor is calculated from following formula: The duration of one cycle = 70.346ms Effective period of the cycle =( 0.65*36+ 1.3*7+2.5986) ms= 35.0986ms DC =35.098/70.346= 0.4989or 49.89% Therefore, the averaging factor is found by 20lg0.4989=-6.0 Please refer to below plots for more details.

Date: 29.AUG.2022 12:06:18

Version: 03 September 2021

Page 14 of 21

FCC Part 15.231-e

TEST REPORT

Intertek Report No.: 220610072GZU-001

Date: 29.AUG.2022 12:07:52

Date: 29.AUG.2022 12:09:08

Version: 03 September 2021

Page 15 of 21

FCC Part 15.231-e

TEST REPORT

Intertek Report No.: 220610072GZU-001

Date: 29.AUG.2022 12:09:38
Used Test Equipment List: 3m Semi-Anechoic Chamber, EMI Test Receiver (9 kHz~7 GHz), Signal and Spectrum Analyzer (10 Hz~40 GHz), Loop antenna (9 kHz-30 MHz). TRILOG Super Broadband test Antenna(30 MHz3 GHz(RX), Bouble-Ridged Waveguide Horn Antenna (800 MHz-18 GHz)(RX) and High Frequency Antenna & preamplifier(18 GHz~26.5 GHz) (RX). Refer to Clause 5 Test Equipment List for details.
1) Fundamental emission:

Polarization
Horizontal Vertical

Frequency (MHz) 433.91 433.91

PK Reading (dBuV) 63.6 45.4

Correction Factor(dB)
18.3 18.3

PK value (dBuV/m)
81.9 63.7

PK limit (dBuV/m)
100.8 100.8

Margin (dB) 18.9 37.1

Polarization
Horizontal Vertical

Frequency (MHz) 433.91 433.91

PK value (dBuV/m)
81.9 63.7

Average Factor(dB)
-6.0 -6.0

AV value (dBuV/m)
75.9 57.7

AV limit (dBuV/m)
80.8 80.8

Margin (dB) 4.9 23.1

Y: rotate EUT by 90 vertically. X: rotate EUT by 90 clockwise. Z: EUT as Radiated Emission test setup photograph.

Version: 03 September 2021

Page 16 of 21

FCC Part 15.231-e

Intertek Report No.: 220610072GZU-001

TEST REPORT
1. Corr. (dB/m) = Antenna Factor (dB/m) + Cable Loss (dB) 2. Level (dBV/m) = Corr. (dB/m) + Read Level (dBV/m) 3. Margin (dB) = Limit Line (dBV/m) ­Level (dBV/m)
2) other emissions: The receiver was scanned from the lowest frequency generated within the EUT to 5 GHz. The field strength is calculated by adding the Antenna Factor, Cable Factor & Peramplifier. The basic equation with a sample calculation is as follows: Final Test Level =Receiver Reading + Antenna Factor + Cable Factor ­Peramplifier Factor. The following test results were performed on the EUT. If the peak emission level is lower than the average limit, the average emission level does not need to show. Test the EUT in transmitting mode:

9 kHz~30 MHz Field Strength of Unwanted Emissions. Peak or Quasi-Peak measurement.
The measurements with active loop antenna were greater than 20dB below the limit, so the test data were not recorded in the test report.

30 MHz~5 GHz Field Strength of Unwanted Emissions. Peak or Quasi-Peak measurement:

Polarization Frequency (MHz)

Horizontal Vertical
Horizontal Vertical

867.8 867.8 3037.5 3037.5

PK Reading (dBuV)
20.9 18.3 49.3 55.2

Correction PK value PK limit Factor(dB) (dBuV/m) (dBuV/m)

24.6

45.5

80.8

24.6

42.9

80.8

-5.8

43.5

80.8

-5.8

49.4

80.8

Margin (dB)
35.3 37.9 37.3 31.4

Polarization
Horizontal Vertical
Horizontal Vertical

Frequency (MHz) 867.8 867.8 3037.5 3037.5

PK value (dBuV/m)
45.5 42.9 43.5 49.4

Average Factor(dB)
-6.0 -6.0 -6.0 -6.0

AV Level (dBV/m)
39.5 36.9 37.5 43.4

Average (dBuV/m)
60.8 60.8 60.8 60.8

Margin (dB) 21.3 23.9 23.3 17.4

Remark: According to 15.35 (b) When average radiated emission measurements are specified in the regulations, including emission measurements below 1000 MHz, there is also a limit on the radio frequency emissions, as measured using instrumentation with a peak detector function, corresponding to 20 dB above the maximum permitted average limit for the frequency being investigated unless a different peak emission limit is otherwise specified in the rules, e.g., see Section 15.255.

Version: 03 September 2021

Page 17 of 21

FCC Part 15.231-e

TEST REPORT

Intertek Report No.: 220610072GZU-001

4.3 Occupied Bandwidth

Test Requirement:

FCC Part 15 C section 15.231 (c)

Test Method:

ANSI C63.10: Clause 6.9

Test Status:

Test in transmitting mode at lowest and highest channel.

Requirements:

15.231 (c) The bandwidth of the emission shall be no wider than 0.25% of the center frequency for devices operating above 70 MHz and below 900 MHz. For devices operating above 900 MHz, the emission shall be no wider than 0.5% of the center frequency. Bandwidth is determined at the points 20 dB down from the modulated carrier.

Method of measurement: The useful radiated emission from the EUT was detected by the spectrum analyzer with peak detector. Record the 20 dB bandwidth of the carrier.
Used Test Equipment List: Spectrum Analyzer. Refer to Clause 5 Test Equipment List for details.

Test result:

Test Channel

bandwidth

433.9 MHz

7.236kHz

Remark:

The bandwidth limit is 433.9 x 0.0025 = 1.08 MHz

Test plot:

Limit 1.08 MHz

Date: 29.AUG.2022 12:04:25
Version: 03 September 2021

Page 18 of 21

FCC Part 15.231-e

TEST REPORT

Intertek Report No.: 220610072GZU-001

4.4 Dwell Time

Test Requirement:

FCC Part 15 C section 15.231(a)

Test Method:

FCC Part 15 C section 15.231(a)

Test Status:

Test in transmitting mode.

Requirements:
1. Regulation 15.231 (a) The provisions of this Section are restricted to periodic operation within the band 40.66 40.70 MHz and above 70 MHz. Except as shown in paragraph (e) of this Section, the intentional radiator is restricted to the transmission of a control signal such as those used with alarm systems, door openers, remote switches, etc. Radio control of toys is not permitted. Continuous transmissions, such as voice or video, and data transmissions are not permitted. The prohibition against data transmissions does not preclude the use of recognition codes. Those codes are used to identify the sensor that is activated or to identify the particular component as being part of the system.

Result:

The EUT is a remote switch without audio or video transmitted.

The EUT meets the requirements of this section.

2. Regulation 15.231 (a1) A manually operated transmitter shall employ a switch that will automatically deactivate the transmitter within not more than 5 seconds of being released.

Result:

Carrier Frequency

Shutdown Time

Limit

433.9MHz

0.414s

5s

Result plot as follows:

Version: 03DaStee:pt2e9m.AbUGe.r2022022112:20:35

Page 19 of 21

FCC Part 15.231-e

TEST REPORT

Intertek Report No.: 220610072GZU-001

3. Regulation 15.231 (a2) A transmitter activated automatically shall cease transmission within 5 seconds after activation. Result: The EUT does not have automatic transmission. 4. Regulation15.231 (a3) Periodic transmissions at regular predetermined intervals are not permitted. However, polling or supervision transmissions to determine system integrity of transmitters used in security or safety applications are allowed if the periodic rate of transmission does not exceed one transmission of not more than one second duration per hour for each transmitter. Result: The EUT does not employ periodic transmission. 5. Regulation 15.231 (a4) Intentional radiators which are employed for radio control purposes during emergencies involving fire, security, and safety of life, when activated to signal an alarm, may operate during the pendency of the alarm condition. Result: This section is not applicable to the EUT.
4.5 Conducted Emission Test
Test result: Not applicable.

Version: 03 September 2021

Page 20 of 21

FCC Part 15.231-e

Intertek Report No.: 220610072GZU-001

TEST REPORT 5.0 Test Equipment List

Radiated Emission/Radio

Equipment No.

Equipment

EM030-04 3m Semi-Anechoic Chamber

EM031-02 EM031-03 EM011-04

EMI Test Receiver (9 kHz~7 GHz) Signal and Spectrum Analyzer (10 Hz~40 GHz)
Loop antenna (9 kHz-30 MHz)

EM061-03 EM033-01 EM033-02

TRILOG Super Broadband test Antenna (30 MHz-1.5 GHz(TX)
TRILOG Super Broadband test Antenna(30 MHz-3 GHz(RX)
Bouble-Ridged Waveguide Horn Antenna (800 MHz-18 GHz)(RX)

EM033-03

High Frequency Antenna & preamplifier(18 GHz~26.5 GHz) (RX)

EM033-04
EM031-02-01 EM033-02-02 EM033-04-02
EM031-01 EM040-01 EM040-02 EM040-03 EM022-03

High Frequency Antenna & preamplifier (26 GHz-40 GHz) Coaxial cable(9 kHz-1 GHz) Coaxial cable(1 GHz-18 GHz) Coaxial cable(18 GHz~40 GHz) Signal Generator (9 kHz~6 GHz) Band Reject/Notch Filter Band Reject/Notch Filter Band Reject/Notch Filter 2.45 GHz Filter

SA016-29 Climatic Test Chamber

SA012-74 EM010-01 SA040-22 EM084-06 EM046-05 EM046-06 EM045-01-01

Digital Multimeter Regulated DC Power supply Regulated DC Power supply Audio Analyzer Power meter Power meter EMC32 software (RE/RS)

EM045-01-09 EMC32 software (328/893)

Conducted emission at the mains terminals

Equipment No.

Equipment

EM080-05 EM006-05 EM006-06 EM006-06-01 EM004-04

EMI receiver LISN LISN Coaxial cable EMC shield Room

Model
9×6×6 m3 R&S ESR7 R&S FSV40 HFH2-Z2
VULB 9161
VULB 9163
R&S HF907
R&S SCU-26
R&S SCU-40
N/A N/A N/A SMB100A WRHFV WRCGV WRCGV BRM50702 MHU-80L FLUKE175 PAB-3003A IT6721 8903B NPR6A NPR6A V10.01.00 V9.26.01
Model ESCI ENV216 ENV216 / 8m×3m×3m

Manufacturer
ETS LINDGREN R&S R&S R&S

Cal. Due date Calibration (YYYY-MM-DD) Interval

2023-04-07

1Y

2022-11-16

1Y

2022-12-23

1Y

2023-06-27

1Y

SCHWARZBECK 2023-06-26

1Y

SCHWARZBECK 2023-10-25

1Y

R&S

2023-06-26

1Y

R&S

2023-04-16

1Y

R&S
R&S R&S R&S R&S Wainwright Wainwright Wainwright Micro-Tronics
JIANQIAO FLUKE GUANHUA ITECH HP R&S R&S R&S R&S

2023-04-16

1Y

2023-04-08

1Y

2023-04-08

1Y

2023-04-15

1Y

2023-07-17

1Y

N/A

1Y

N/A

1Y

N/A

1Y

2023-05-06

1Y

2023-01-20

1Y

2023-10-07

1Y

N/A

1Y

2023-09-04

1Y

2023-04-11

1Y

2023-04-20

1Y

2023-04-20

1Y

N/A

N/A

N/A

N/A

Manufacturer
R&S R&S R&S R&S Zhongyu

Cal. Due date
(YYYY-MM-DD)
2023-06-08 2023-06-05 2023-09-05 2023-04-08 2023-01-06

Calibration Interval 1Y 1Y 1Y 1Y 1Y

********************************End of the test report******************************

Version: 03 September 2021

Page 21 of 21

FCC Part 15.231-e

