Measurement Report

Kent

Test reports

Xiamen Lujiang Technology Co., Ltd. L3 Mini Printer 2A74A-L3 2A74AL3 l3

download (pdf)

L3 Mini Printer by Xiamen Lujiang

PDF Viewing Options

Not Your Device? Search For Manuals or Datasheets below:


File Info : application/pdf, 35 Pages, 3.36MB

Document DEVICE REPORTL3-Test-Report-Xiamen-Lujiang-2a74a-l3-ex-1-9
Shenzhen DL Testing Technology Co., Ltd.

Report No.: DL-20231218049E

FCC Part 15C Test Report FCC ID: 2A74A-L3

Applicant: Address: Manufacturer: Address: EUT:

Xiamen Lujiang Technology Co., Ltd Room 601-2, No.63-1, Wanghai Road, Software Park Phase II, Torch Hi-Tech Zone, Xiamen
Xiamen Lujiang Technology Co., Ltd
Room 601-2, No.63-1, Wanghai Road, Software Park Phase II, Torch Hi-Tech Zone, Xiamen
Mini Printer

Trade Mark:
Model Number: Date of Receipt: Test Date: Date of Report: Prepared By:
Address: Applicable Standards: Test Result: Report Number:

N/A
L3 L3S, L3Pro, A3, A3S, A3Pro Dec. 09, 2023
Dec. 09, 2023 - Dec. 18, 2023
Dec. 18, 2023
Shenzhen DL Testing Technology Co., Ltd. 101-201, Building C, Shuanghuan, No.8, Baoqing Road, Baolong Industrial Zone, Baolong Street, Longgang District, Shenzhen, Guangdong, China FCC PART 15 C 15.249 ANSI C63.10:2013 Pass
DL-20231218049E

Prepared (Test Engineer):

Alisa Song

Reviewer (Supervisor):

Jack Bu

Approved (Manager):

Jade Yang

This test report is based on a single evaluation of one sample of above mentioned products. It is not permitted to be duplicated in extracts without written approval of Shenzhen DL Testing Technology Co., Ltd.

Test Report

Tel: 400-688-3552

Web:www.dl-cert.com

Email: [email protected] Page 1 of 35

Shenzhen DL Testing Technology Co., Ltd. Table of Contents

Report No.: DL-20231218049E Page

1 . SUMMARY OF TEST RESULTS

4

1.1 MEASUREMENT UNCERTAINTY

4

2 . GENERAL INFORMATION

5

2.1 GENERAL DESCRIPTION OF EUT

5

2.2 DESCRIPTION OF TEST MODES

6

2.3 BLOCK DIGRAM SHOWING THE CONFIGURATION OF SYSTEM TESTED

6

2.4 DESCRIPTION OF SUPPORT UNITS(CONDUCTED MODE)

7

2.5 TABLE OF PARAMETERS OF TEST SOFTWARE SETTING

7

2.6 EQUIPMENTS LIST FOR ALL TEST ITEMS

8

3 . EMC EMISSION TEST

9

3.1 CONDUCTED EMISSION MEASUREMENT

9

3.1.1 POWER LINE CONDUCTED EMISSION LIMITS

9

3.1.2 TEST PROCEDURE

9

3.1.3 DEVIATION FROM TEST STANDARD

9

3.1.4 TEST SETUP

10

3.1.5 EUT OPERATING CONDITIONS

10

3.1.6 TEST RESULTS

10

3.2 RADIATED EMISSION MEASUREMENT

13

3.2.1 RADIATED EMISSION LIMITS

13

3.2.2 TEST PROCEDURE

14

3.2.3 DEVIATION FROM TEST STANDARD

14

3.2.4 TEST SETUP

14

3.2.5 EUT OPERATING CONDITIONS

15

3.2.6 TEST RESULTS (BETWEEN 9KHZ ­ 30 MHZ)

16

3.2.7 TEST RESULTS (BETWEEN 30MHZ ­ 1GHZ)

17

3.2.8 TEST RESULTS (1GHZ~25GHZ)

19

3.3 RADIATED BAND EMISSION MEASUREMENT

20

3.3.1 TEST REQUIREMENT:

20

3.3.2 TEST PROCEDURE

20

3.3.3 DEVIATION FROM TEST STANDARD

20

3.3.4 TEST SETUP

21

3.3.5 EUT OPERATING CONDITIONS

21

4 . BANDWIDTH TEST

23

4.1 APPLIED PROCEDURES / LIMIT

23

4.1.1 TEST PROCEDURE

23

4.1.2 DEVIATION FROM STANDARD

23

4.1.3 TEST SETUP

23

4.1.4 EUT OPERATION CONDITIONS

23

Test Report

Tel: 400-688-3552

Web:www.dl-cert.com

Email: [email protected] Page 2 of 35

Shenzhen DL Testing Technology Co., Ltd. Table of Contents
4.1.5 TEST RESULTS 5 . ANTENNA REQUIREMENT
5.1 STANDARD REQUIREMENT 5.2 EUT ANTENNA 6 . TEST SEUUP PHOTO 7 . EUT PHOTO

Report No.: DL-20231218049E Page
24 25 25 25 26 28

Test Report

Tel: 400-688-3552

Web:www.dl-cert.com

Email: [email protected] Page 3 of 35

Shenzhen DL Testing Technology Co., Ltd.

Report No.: DL-20231218049E

1. SUMMARY OF TEST RESULTS Test procedures according to the technical standards:

FCC Part15 (15.249) , Subpart C

Standard Section
15.207
15.205(a), 15.209(a) 15.249(a), 15.249(c)
15.249(d)

Test Item
Conducted Emission Fundamental &Radiated Spurious Emission
Measurement Band Edge Emission

Judgment PASS PASS PASS

15.215(c)

20dB Bandwidth

PASS

15.203

Antenna Requirement

PASS

Remark

NOTE:

(1)" N/A" denotes test is not applicable in this Test Report

Test lab: Shenzhen DL Testing Technology Co., Ltd.

Address:

101-201, Building C, Shuanghuan, No.8, Baoqing Road, Baolong Industrial Zone, Baolong Street, Longgang District, Shenzhen, Guangdong, China

FCC Test Firm Registration Number: 854456

Designation Number: CN1307

IC Registered No.: 27485

CAB ID.: CN0118

1.1 MEASUREMENT UNCERTAINTY The reported uncertainty of measurement y ± U, where expended uncertainty U is based on a standard uncertainty multiplied by a coverage factor of k=2,providing a level of confidence of approximately 95 %.

No.

Item

1

Conducted Emission Test

2

RF power,conducted

3

Spurious emissions,conducted

4

All emissions,radiated(<1G)

5

All emissions,radiated(>1G)

6

Temperature

7

Humidity

8

20dB Bandwidth

Uncertainty ±2.56dB ±0.42dB ±2.76dB ±3.65dB ±4.89dB ±0.5°C ±2% ±0.2MHz

Test Report

Tel: 400-688-3552

Web:www.dl-cert.com

Email: [email protected] Page 4 of 35

Shenzhen DL Testing Technology Co., Ltd.

Report No.: DL-20231218049E

2. GENERAL INFORMATION 2.1 GENERAL DESCRIPTION OF EUT

Product Name: Trademark
Model No.:
Model Difference Operation Frequency: Channel numbers: Channel separation: Modulation technology: Antenna Type: Antenna gain:
Power supply:

Mini Printer
N/A L3 L3S, L3Pro, A3, A3S, A3Pro The product's different for model number and appearance color. 2402~2480MHz 40 Channels 2M GFSK PCB Antenna 1.09dBi DC 7.4V from battery DC 5V from charger

Note: 1.For a more detailed features description, please refer to the manufacturer's specifications or the User's Manual. 2.The EUT's all information provided by client.

3.

Channel List

Channel

Frequency (MHz)

Channel

Frequency (MHz)

Channel

Frequency (MHz)

00

2402

14

2430

27

2456

01

2404

15

2432

28

2458

02

2406

16

2434

29

2460

03

2408

17

2436

30

2462

04

2410

18

2438

31

2464

05

2412

19

2440

32

2466

06

2414

20

2442

33

2468

07

2416

21

2444

34

2470

08

2418

22

2446

35

2472

09

2420

23

2448

36

2474

10

2422

24

2450

37

2476

11

2424

25

2452

38

2478

12

2426

26

2454

39

2480

13

2428

/

/

/

/

Test Report

Tel: 400-688-3552

Web:www.dl-cert.com

Email: [email protected] Page 5 of 35

Shenzhen DL Testing Technology Co., Ltd.

Report No.: DL-20231218049E

2.2 DESCRIPTION OF TEST MODES

To investigate the maximum EMI emission characteristics generates from EUT, the test system was pre-scanning tested base on the consideration of following EUT operation mode or test configuration mode which possible have effect on EMI emission level. Each of these EUT operation mode(s) or test configuration mode(s) mentioned above was evaluated respectively.

Pretest Mode

Description

Mode 1

CH00

Mode 2

CH19

GFSK

Mode 3

CH39

Mode 4

Link Mode

For Conducted & Radiated Emission

Final Test Mode Mode 1 Mode 2 Mode 3

Description CH00 CH19 CH39

GFSK

Mode 4

Link Mode

Mode 5

Charging Mode

Note:
(1) The measurements are performed at the highest, middle, lowest available channels. (2) A new fully charged battery was used for testing during the test.

2.3 BLOCK DIGRAM SHOWING THE CONFIGURATION OF SYSTEM TESTED Radiated Spurious Emission Test

E-1 EUT

Conducted Spurious Emission Test

E-1 EUT

C1

E-2

Adapter

AC Mains

Test Report

Tel: 400-688-3552

Web:www.dl-cert.com

Email: [email protected] Page 6 of 35

Shenzhen DL Testing Technology Co., Ltd.

Report No.: DL-20231218049E

2.4 DESCRIPTION OF SUPPORT UNITS(CONDUCTED MODE)
The EUT has been tested as an independent unit together with other necessary accessories or support units. The following support units or accessories were used to form a representative test configuration during the tests.

Item

Equipment

E-1

MINI POCKET PRINTER

E-2

Adapter

Model/Type No. L3
HW-0502000E

Series No. N/A N/A

Note EUT

Item Shielded Type Ferrite Core

Length

Note

Note: (1) For detachable type I/O cable should be specified the length in cm inLengthcolumn.

2.5 TABLE OF PARAMETERS OF TEST SOFTWARE SETTING
During testing, channel & power controlling software provided by the customer was used to control the operating channel as well as the output power level. The RF output power selection is for the setting of RF output power expected by the customer and is going to be fixed on the end product.

Test software Version Frequency
Power Setting of Softwave

Test program: BK RF Test_V1.8

2402 MHz 10

2440 MHz 10

2480 MHz 10

Test Report

Tel: 400-688-3552

Web:www.dl-cert.com

Email: [email protected] Page 7 of 35

Shenzhen DL Testing Technology Co., Ltd.

Report No.: DL-20231218049E

2.6 EQUIPMENTS LIST FOR ALL TEST ITEMS

Radiation test, Band-edge test and 20db bandwidth test equipment

Item

Equipment

Manufacturer Type No.

Serial No.

1

Spectrum Analyzer (9kHz-26.5GHz)

Agilent

E4408B

MY50140780

2

Test Receiver (9kHz-7GHz)

R&S

ESRP7

101393

3

Bilog Antenna (30MHz-1GHz)

R&S

VULB9162

00306

4

Horn Antenna (1GHz-18GHz)

Schwarzbeck BBHA9120D

02139

5

Horn Antenna (18GHz-40GHz)

A.H. Systems

SAS-574

6

Amplifier (9KHz-6GHz)

Schwarzbeck BBV9743B

588 00153

7

Amplifier (1GHz-18GHz)

EMEC

EM01G8GA

00270

8

Amplifier (18GHz-40GHz)

Quanjuda

DLE-161

9

Loop Antenna (9KHz-30MHz)

Schwarzbeck FMZB1519B

97 00014

10

RF cables1 (9kHz-1GHz)

ChengYu

966

004

11

RF cables2 (1GHz-40GHz)

ChengYu

966

003

12 Antenna connector Florida RF Labs

N/A

RF 01#

13 Power probe

KEYSIGHT

U2021XA MY55210018

14

Signal Analyzer 9kHz-26.5GHz

15

Test Receiver 20kHz-40GHz

Agilent R&S

N9020A ESU 40

MY55370280 100376

16 D.C. Power Supply LongWei

PS-305D

010964729

Last calibration Calibrated until Nov. 04, 2023 Nov. 03, 2024 Nov. 04, 2023 Nov. 03, 2024 Nov. 04, 2023 Nov. 03, 2024 Nov. 04, 2023 Nov. 03, 2024 Nov. 04, 2023 Nov. 03, 2024 Nov. 04, 2023 Nov. 03, 2024 Nov. 04, 2023 Nov. 03, 2024 Nov. 04, 2023 Nov. 03, 2024 Nov. 04, 2023 Nov. 03, 2024 Nov. 04, 2023 Nov. 03, 2024 Nov. 04, 2023 Nov. 03, 2024 Nov. 04, 2023 Nov. 03, 2024 Nov. 04, 2023 Nov. 03, 2024 Nov. 04, 2023 Nov. 03, 2024 Nov. 04, 2023 Nov. 03, 2024 Nov. 04, 2023 Nov. 03, 2024

Conduction Test equipment

Item

Equipment

Manufacturer

1 843 Shielded Room ChengYu

2

EMI Receiver

R&S

3

LISN

R&S

4

843 Cable 1#

ChengYu

Type No. 843 Room
ESR ENV216 CE Cable

Serial No. 843
101421 102417
001

Last calibration Calibrated until Sep. 20, 2022 Sep. 19, 2025 Nov. 04, 2023 Nov. 03, 2024 Nov. 04, 2023 Nov. 03, 2024 Nov. 04, 2023 Nov. 03, 2024

Other

Item

Name

1 EMC Conduction Test System

2

EMC radiation test system

3

RF test system

4 RF communication test system

Manufacturer FALA FALA
MAIWEI MAIWEI

Model EZ_EMC EZ_EMC MTS8310 MTS8200

Software version EMC-CON 3A1.1
FA-03A2 2.0.0.0 2.0.0.0

Test Report

Tel: 400-688-3552

Web:www.dl-cert.com

Email: [email protected] Page 8 of 35

Shenzhen DL Testing Technology Co., Ltd.

Report No.: DL-20231218049E

3. EMC EMISSION TEST 3.1 CONDUCTED EMISSION MEASUREMENT 3.1.1 POWER LINE CONDUCTED EMISSION Limits

(Frequency Range 150KHz-30MHz)

FREQUENCY (MHz)

Limit (dBuV) Quasi-peak

Average

Standard

0.15 -0.5

66 - 56 *

56 - 46 *

FCC

0.50 -5.0

56.00

46.00

FCC

5.0 -30.0

60.00

50.00

FCC

Note:

(1) The tighter limit applies at the band edges.

(2) The limit of " * " marked band means the limitation decreases linearly with the logarithm of the frequency in the range.

The following table is the setting of the receiver Receiver Parameters Attenuation Start Frequency Stop Frequency IF Bandwidth

Setting 10 dB 0.15 MHz 30 MHz 9 kHz

3.1.2 TEST PROCEDURE
a. The EUT was placed 0.8 meters from the horizontal ground plane with EUT being connected to the power mains through a line impedance stabilization network (LISN). All other support equipments powered from additional LISN(s). The LISN provide 50 Ohm/ 50uH of coupling impedance for the measuring instrument.
b. Interconnecting cables that hang closer than 40 cm to the ground plane shall be folded back and forth in the center forming a bundle 30 to 40 cm long.
c. I/O cables that are not connected to a peripheral shall be bundled in the center. The end of the cable may be terminated, if required, using the correct terminating impedance. The overall length shall not exceed 1 m.
d. LISN at least 80 cm from nearest part of EUT chassis. e. For the actual test configuration, please refer to the related Item ­EUT Test Photos.
3.1.3 DEVIATION FROM TEST STANDARD
No deviation

Test Report

Tel: 400-688-3552

Web:www.dl-cert.com

Email: [email protected] Page 9 of 35

Shenzhen DL Testing Technology Co., Ltd.

Report No.: DL-20231218049E

3.1.4 TEST SETUP

Vertical Reference Ground Plane

40cm

EUT

Test Receiver

LISN

80cm

Horizontal Reference Ground Plane

Note: 1.Support units were connected to second LISN.

2.Both of LISNs (AMN) are 80 cm from EUT and at least 80

cm

from other units and other metal planes

support. units.

3.1.5 EUT OPERATING CONDITIONS The EUT was configured for testing in a typical fashion (as a customer would normally use it). The EUT has been programmed to continuously transmit during test. This operating condition was tested and used to collect the included data. We pretest AC 120V and AC 230V, the worst voltage was AC 120V and the data recording in the report.
3.1.6 TEST RESULTS

Test Report

Tel: 400-688-3552

Web:www.dl-cert.com

Email: [email protected] Page 10 of 35

Temperature: Pressure: Test Voltage :

Shenzhen DL Testing Technology Co., Ltd.

Report No.: DL-20231218049E

25  1010hPa AC 120V/60Hz

Relative Humidity: Phase : Test Mode:

54% L Mode 5

Remark: Margin = Limit ­ Level, Correct Factor = Cable lose + LISN insertion loss, Level= Reading + Correct factor

Test Report

Tel: 400-688-3552

Web:www.dl-cert.com

Email: [email protected] Page 11 of 35

Temperature: Pressure: Test Voltage :

Shenzhen DL Testing Technology Co., Ltd.

Report No.: DL-20231218049E

25  1010hPa AC 120V/60Hz

Relative Humidity: Phase : Test Mode:

54% N Mode 5

Remark: Margin = Limit ­ Level, Correct Factor = Cable lose + LISN insertion loss, Level= Reading + Correct factor

Test Report

Tel: 400-688-3552

Web:www.dl-cert.com

Email: [email protected] Page 12 of 35

Shenzhen DL Testing Technology Co., Ltd.

Report No.: DL-20231218049E

3.2 RADIATED EMISSION MEASUREMENT 3.2.1 RADIATED EMISSION LIMITS (Frequency Range 9kHz-1000MHz)

In case the emission fall within the restricted band specified on 15.205(a), then the 15.209(a) limit in the table below has to be followed.

Frequency (MHz)

Field Strength (micorvolts/meter) Measurement Distance (meters)

0.009~0.490

2400/F(KHz)

300

0.490~1.705

24000/F(KHz)

30

1.705~30.0

30

30

30~88

100

3

88~216

150

3

216~960

200

3

Above 960

500

3

The field strength of emissions from intentional radiators operated within these frequency bands shall comply with the following:

Fundamental Frequency
902 - 928 MHz 2400 - 2483.5 MHz 5725 - 5875 MHz 24.0 - 24.25 GHz

Field Strength of Fundamental (millivolts/meter) 50 50 50 250

Field Strength of Harmonics (microvolts/meter) 500 500 500 2500

LIMITS OF RADIATED EMISSION MEASUREMENT (Above 1000MHz)

FREQUENCY (MHz)

Limit (dBuV/m) (at 3M)

PEAK

AVERAGE

Above 1000

74

54

Notes:

(1) The limit for radiated test was performed according to FCC PART 15C.

(2) The tighter limit applies at the band edges.

(3) Emission level (dBuV/m)=20log Emission level (uV/m).

Receiver setup: Frequency
9KHz-150KHz 150KHz-30MHz
30MHz-1GHz
Above 1GHz

Detector Quasi-peak Quasi-peak Quasi-peak
Peak Peak

RBW 200Hz 9KHz 100KHz 1MHz 1MHz

VBW 600Hz 30KHz 300KHz 3MHz 10Hz

Value Quasi-peak Quasi-peak Quasi-peak
Peak Average

Test Report

Tel: 400-688-3552

Web:www.dl-cert.com

Email: [email protected] Page 13 of 35

Shenzhen DL Testing Technology Co., Ltd.

Report No.: DL-20231218049E

3.2.2 TEST PROCEDURE Below 1GHz test procedure as below:
a. The EUT was placed on the top of a rotating table 0.8 meters above the ground at a 3 meter semi-anechoic camber. The table was rotated 360 degrees to determine the position of the highest radiation.
b. The EUT was set 3 meters away from the interference-receiving antenna, which was mounted on the top of a variable-height antenna tower.
c. The antenna height is varied from one meter to four meters above the ground to determine the maximum value of the field strength. Both horizontal and vertical polarizations of the antenna are set to make the measurement.
d. For each suspected emission, the EUT was arranged to its worst case and then the antenna was tuned to heights from 1 meter to 4 meters (for the test frequency of below 30MHz, the antenna was tuned to heights 1 meter) and the rotatable table was turned from 0 degrees to 360 degrees to find the maximum reading.
e. The test-receiver system was set to Peak Detect Function and Specified Bandwidth with Maximum Hold Mode.
f. If the emission level of the EUT in peak mode was 10dB lower than the limit specified, then testing could be stopped and the peak values of the EUT would be reported. Otherwise the emissions that did not have 10dB margin would be re-tested one by one using peak, quasi-peak or average method as specified and then reported in a data sheet.
Above 1GHz test procedure as below:
g. The EUT was placed on the top of a rotating table 0.8 meters above the ground at a 3 meter semi-anechoic camber. ( Above 18GHz the distance is 3 meter and table is 1.5 metre).
h. Test the EUT in the lowest channel ,the middle channel ,the Highest channel
Note:
Both horizontal and vertical antenna polarities were tested and performed pretest to three orthogonal axis. The worst case emissions were reported
3.2.3 DEVIATION FROM TEST STANDARD No deviation
3.2.4 TEST SETUP
ARadiated Emission Test-Up Frequency Below 30MHz

Semi-anechoic 3m Chamber
Turn Table From 0°to 360°

1m
EUT

0.8m

Turn Table

PC System

Spectrum Analyzer

AMP

Combining Network

Test Report

Tel: 400-688-3552

Web:www.dl-cert.com

Email: [email protected] Page 14 of 35

Shenzhen DL Testing Technology Co., Ltd. BRadiated Emission Test-Up Frequency 30MHz~1GHz

Semi-anechoic 3m Chamber
Antenna Elevation Varies From 1 to 4 m Turn Table From 0°to 360°
3m
EUT

0.8m

Turn Table

Report No.: DL-20231218049E

PC System

Spectrum Analyzer

CRadiated Emission Test-Up Frequency Above 1GHz

Aechoic 3m Chamber
Antenna Elevation Varies From 1 to 4 m Turn Table From 0°to 360°
3m

EUT

AMP

Combining Network

1.5m

Turn Table

Absorbers

PC System

Spectrum Analyzer

AMP

Combining Network

3.2.5 EUT OPERATING CONDITIONS
The EUT tested system was configured as the statements of 2.3 Unless otherwise a special operating condition is specified in the follows during the testing.

Test Report

Tel: 400-688-3552

Web:www.dl-cert.com

Email: [email protected] Page 15 of 35

Shenzhen DL Testing Technology Co., Ltd.

Report No.: DL-20231218049E

3.2.6 TEST RESULTS (BETWEEN 9KHZ ­ 30 MHZ)

Temperature: Pressure: Test Mode :

20 1010 hPa Mode 4

Relative Humidtity: Test Voltage : Polarization :

48% DC 7.4V --

Freq. (MHz)
---

Reading (dBuV/m)
---

Limit (dBuV/m)
---

Margin (dB) ---

State P/F PASS PASS

NOTE:
The amplitude of spurious emissions which are attenuated by more than 20dB below the permissible value has no need to be reported. Distance extrapolation factor =40 log (specific distance/test distance)(dB); Limit line = specific limits(dBuv) + distance extrapolation factor.

Test Report

Tel: 400-688-3552

Web:www.dl-cert.com

Email: [email protected] Page 16 of 35

Shenzhen DL Testing Technology Co., Ltd.

Report No.: DL-20231218049E

3.2.7 TEST RESULTS (BETWEEN 30MHZ ­ 1GHZ)

Temperature: Pressure: Test Voltage : Test Mode :

26 1010 hPa DC 7.4V Mode 4

Relative Humidity: Polarization :

54% Horizontal

Remark: Correct Factor = Cable loss + Antenna factor ­ Preamplifier; Level = Reading Level + Correct Factor; Margin = Level - Limit;

Test Report

Tel: 400-688-3552

Web:www.dl-cert.com

Email: [email protected] Page 17 of 35

Shenzhen DL Testing Technology Co., Ltd.

Report No.: DL-20231218049E

Temperature: Pressure: Test Voltage : Test Mode :

26 1010 hPa DC 7.4V Mode 4

Relative Humidity: Polarization :

54% Vertical

Remark: Correct Factor = Cable loss + Antenna factor ­ Preamplifier; Level = Reading Level + Correct Factor; Margin = Level - Limit;

Test Report

Tel: 400-688-3552

Web:www.dl-cert.com

Email: [email protected] Page 18 of 35

Shenzhen DL Testing Technology Co., Ltd.

Report No.: DL-20231218049E

3.2.8 TEST RESULTS (1GHZ~25GHZ)

GFSK

Polar (H/V)
V V V V V H H H H H

Frequency (MHz)
2402.00 2402.00 4804.00 4804.00 16132.00 2402.00 2402.00 4804.00 4804.00 16132.00

Meter Reading (dBuV)
113.14 106.35 78.18 60.54 54.29 113.15 105.58 77.46 59.23 54.37

Pre- Cable Antenna Emission amplifier Loss Factor Level
(dB) (dB) (dB/m) (dBuV/m) operation frequency:2402

52.16 2.78 27.41

91.17

52.16 2.78 27.41

84.38

51.74 3.08 31.25

60.77

51.74 3.08 31.25

43.13

51.56 7.36 41.57

51.66

52.16 2.78 27.41

91.18

52.16 2.78 27.41

83.61

51.74 3.08 31.25

60.05

51.74 3.08 31.25

41.82

51.56 7.36 41.57

51.74

operation frequency:2440

Limits (dBuV/m)
114 94 74 54 74 114 94 74 54 74

Margin (dB)
-22.83 -9.62 -13.23 -10.87 -22.34 -22.82 -10.39 -13.95 -12.18 -22.26

Detector Type
PK AV PK AV PK PK AV PK AV PK

V

2440.00 112.12 52.11 2.82 27.47

90.3

114

-23.7

PK

V

2440.00 105.63 52.11 2.82 27.47

83.81

V

4880.00

77.52

51.77 3.03 31.34

60.12

V

4880.00

60.28

51.77 3.03 31.34

42.88

V 16132.00 54.24

51.56 7.36 41.57

51.61

H

2440.00 112.96 52.11 2.82 27.47

91.14

H

2440.00 104.15 52.11 2.82 27.47

82.33

H

4880.00

76.53

51.77 3.03 31.34

59.13

H

4880.00

59.34

51.77 3.03 31.34

41.94

H 16132.00 55.27

51.56 7.36 41.57

52.64

operation frequency:2480

94

-10.19

AV

74

-13.88

PK

54

-11.12

AV

74

-22.39

PK

114

-22.86

PK

94

-11.67

AV

74

-14.87

PK

54

-12.06

AV

74

-21.36

PK

V

2480.00 112.36 52.23 2.86 27.44

90.43

114

-23.57

PK

V

2480.00 105.85 52.23 2.86 27.44

V

4960.00

76.25

51.69 3.05 31.39

V

4960.00

61.34

51.69 3.05 31.39

V 16132.00 53.46

51.56 7.36 41.57

H

2480.00 112.24 52.23 2.86 27.44

H

2480.00 106.16 52.23 2.86 27.44

H

4960.00

78.68

51.69 3.05 31.39

H

4960.00

58.41

51.69 3.05 31.39

H 16132.00 53.18

51.56 7.36 41.57

83.92 59
44.09 50.83 90.31 84.23 61.43 41.16 50.55

94

-10.08

AV

74

-15

PK

54

-9.91

AV

74

-23.17

PK

114

-23.69

PK

94

-9.77

AV

74

-12.57

PK

54

-12.84

AV

74

-23.45

PK

Remark:
1. Emission Level = Meter Reading + Antenna Factor + Cable Loss ­ Pre-amplifier, Margin= Emission Level - Limit
2. If peak below the average limit, the average emission was no test. 3. The amplitude of spurious emissions which are attenuated by more than 20dB below the permissible value has no need to be reported.

Test Report

Tel: 400-688-3552

Web:www.dl-cert.com

Email: [email protected] Page 19 of 35

Shenzhen DL Testing Technology Co., Ltd.

Report No.: DL-20231218049E

3.3 RADIATED BAND EMISSION MEASUREMENT 3.3.1 TEST REQUIREMENT: FCC Part15 C Section 15.209 and 15.205
LIMITS OF RADIATED EMISSION MEASUREMENT (Above 1000MHz)

FREQUENCY (MHz)

Limit (dBuV/m) (at 3M)

PEAK

AVERAGE

Above 1000

74

54

Notes:

(1) The limit for radiated test was performed according to FCC PART 15C.

(2) The tighter limit applies at the band edges.

(3) Emission level (dBuV/m)=20log Emission level (uV/m).

Spectrum Parameter Attenuation
Start Frequency Stop Frequency RB / VB (emission in restricted band)

Setting Auto
2300MHz 2520MHz 1 MHz / 1 MHz for Peak, 1 MHz / 10Hz for Average

3.3.2 TEST PROCEDURE Above 1GHz test procedure as below:
a. 1. The EUT was placed on the top of a rotating table 1.5 meters above the ground at a 3 meter camber. The table was rotated 360 degrees to determine the position of the highest radiation.
b. The EUT was set 3 meters away from the interference-receiving antenna, which was mounted on the top of a variable-height antenna tower.
c. The antenna height is varied from one meter to four meters above the ground to determine the maximum value of the field strength. Both horizontal and vertical polarizations of the antenna are set to make the measurement.
d. For each suspected emission, the EUT was arranged to its worst case and then the antenna was tuned to heights from 1 meter to 4 meters and the rota table was turned from 0 degrees to 360 degrees to find the maximum reading.
e. The test-receiver system was set to Peak Detect Function and Specified Bandwidth with Maximum Hold Mode.
f. If the emission level of the EUT in peak mode was 10dB lower than the limit specified, then testing could be stopped and the peak values of the EUT would be reported. Otherwise the emissions that did not have 10dB margin would be re-tested one by one using peak, quasi-peak or average method as specified and then reported in a data sheet.
g. Test the EUT in the lowest channel,the Highest channel
Note:
Both horizontal and vertical antenna polarities were tested and performed pretest to three orthogonal axis. The worst case emissions were reported

3.3.3 DEVIATION FROM TEST STANDARD No deviation

Test Report

Tel: 400-688-3552

Web:www.dl-cert.com

Email: [email protected] Page 20 of 35

Shenzhen DL Testing Technology Co., Ltd. 3.3.4 TEST SETUP Radiated Emission Test-Up Frequency Above 1GHz
Aechoic 3m Chamber
Antenna Elevation Varies From 1 to 4 m Turn Table From 0°to 360°
3m
EUT

1.5m

Turn Table

Absorbers

Report No.: DL-20231218049E

PC System

Spectrum Analyzer

AMP

Combining Network

3.3.5 EUT OPERATING CONDITIONS
The EUT tested system was configured as the statements of 2.3 Unless otherwise a special operating condition is specified in the follows during the testing.

Test Report

Tel: 400-688-3552

Web:www.dl-cert.com

Email: [email protected] Page 21 of 35

Shenzhen DL Testing Technology Co., Ltd.

Report No.: DL-20231218049E

3.3.6 TEST RESULT

GFSK

Polar (H/V)
V

Frequency (MHz)
2390.00

Meter Reading (dBuV)
76.22

Pre- Cable Antenna Emission amplifier Loss Factor Level
(dB) (dB) (dB/m) (dBuV/m)

operation frequency:2402

52.12 2.73 27.38

54.21

Limits (dBuV/m)
74

Margin (dB)
-19.79

Detector Type
PK

V

2390.00 65.58

52.12 2.73 27.38

43.57

54

-10.43

AV

V

2400.00 76.14

52.16 2.78 27.41

54.17

V

2400.00 64.63

52.16 2.78 27.41

42.66

74

-19.83

PK

54

-11.34

AV

H

2390.00 76.27

52.12 2.73 27.38

54.26

74

-19.74

PK

H

2390.00 65.84

52.12 2.73 27.38

43.83

H

2400.00 76.39

52.16 2.78 27.41

54.42

54

-10.17

AV

74

-19.58

PK

H

2400.00 65.45

52.16 2.78 27.41

43.48

54

-10.52

AV

Polar (H/V)
V

Frequency (MHz)
2483.50

Meter Reading (dBuV)
75.33

Pre- Cable Antenna Emission amplifier Loss Factor Level
(dB) (dB) (dB/m) (dBuV/m)

operation frequency:2480

52.23 2.86 27.44

53.4

Limits (dBuV/m)
74

Margin (dB)
-20.6

Detector Type
PK

V

2483.50 66.29

52.23 2.86 27.44

44.36

54

-9.64

AV

V

2500.00 75.64

52.26 2.88 27.49

53.75

74

-20.25

PK

V

2500.00 65.55

52.26 2.88 27.49

43.66

54

-10.34

AV

H

2483.50 75.54

52.23 2.86 27.44

53.61

74

-20.39

PK

H

2483.50

64.93

52.23 2.86 27.44

43

54

-11

AV

H

2500.00 75.34

52.26 2.88 27.49

53.45

74

-20.55

PK

H

2500.00 66.61

52.26 2.88 27.49

44.72

54

-9.28

AV

Remark:
1. Emission Level = Meter Reading + Antenna Factor + Cable Loss ­ Pre-amplifier, Margin= Emission Level - Limit
2. If peak below the average limit, the average emission was no test. 3. The amplitude of spurious emissions which are attenuated by more than 20dB below the permissible value has no need to be reported.

Test Report

Tel: 400-688-3552

Web:www.dl-cert.com

Email: [email protected] Page 22 of 35

Shenzhen DL Testing Technology Co., Ltd.

4. BANDWIDTH TEST
4.1 APPLIED PROCEDURES / LIMIT FCC Part15 (15.215) , Subpart C

Section

Test Item

15.215

Bandwidth

Report No.: DL-20231218049E

4.1.1 TEST PROCEDURE
1. Set RBW = 30 kHz. 2. Set the video bandwidth (VBW) RBW. 3. Detector = Peak. 4. Trace mode = max hold. 5. Sweep = auto couple. 6. Allow the trace to stabilize. 7. Measure the maximum width of the emission that is constrained by the frequencies associated with the two outermost amplitude points (upper and lower frequencies) that are attenuated by 20 dB relative to the maximum level measured in the fundamental emission.

4.1.2 DEVIATION FROM STANDARD No deviation. 4.1.3 TEST SETUP

4.1.4 EUT OPERATION CONDITIONS
The EUT tested system was configured as the statements of 2.3 Unless otherwise a special operating condition is specified in the follows during the testing.

Test Report

Tel: 400-688-3552

Web:www.dl-cert.com

Email: [email protected] Page 23 of 35

Shenzhen DL Testing Technology Co., Ltd.

Report No.: DL-20231218049E

4.1.5 TEST RESULTS

Temperature: Pressure: Test Mode :

25 1012 hPa TX Mode /CH00, CH19, CH39

Relative Humidity: Test Voltage :

60% DC 7.4V

GFSK

Frequency (MHz)
2402 2440 2480

20dB Bandwidth (MHz)
1.127 1.126 1.129
GFSK

Result
Pass Pass Pass

2402MHz

2480MHz

2440MHz

Test Report

Tel: 400-688-3552

Web:www.dl-cert.com

Email: [email protected] Page 24 of 35

Shenzhen DL Testing Technology Co., Ltd.

Report No.: DL-20231218049E

5. ANTENNA REQUIREMENT
5.1 STANDARD REQUIREMENT
15.203 requirement: For intentional device, according to 15.203: an intentional radiator shall be designed to ensure that no antenna other than that furnished by the responsible party
shall be used with the device.
5.2 EUT ANTENNA
The EUT antenna is PCB antenna, It comply with the standard requirement.

Test Report

Tel: 400-688-3552

Web:www.dl-cert.com

Email: [email protected] Page 25 of 35

Shenzhen DL Testing Technology Co., Ltd.

6. TEST SEUUP PHOTO

Radiated Measurement Photos

Report No.: DL-20231218049E

Test Report

Tel: 400-688-3552

Web:www.dl-cert.com

Email: [email protected] Page 26 of 35

Shenzhen DL Testing Technology Co., Ltd. Conducted Measurement Photos

Report No.: DL-20231218049E

Test Report

Tel: 400-688-3552

Web:www.dl-cert.com

Email: [email protected] Page 27 of 35

7. EUT PHOTO

Shenzhen DL Testing Technology Co., Ltd.

Report No.: DL-20231218049E

Test Report

Tel: 400-688-3552

Web:www.dl-cert.com

Email: [email protected] Page 28 of 35

Shenzhen DL Testing Technology Co., Ltd.

Report No.: DL-20231218049E

Test Report

Tel: 400-688-3552

Web:www.dl-cert.com

Email: [email protected] Page 29 of 35

Shenzhen DL Testing Technology Co., Ltd.

Report No.: DL-20231218049E

Test Report

Tel: 400-688-3552

Web:www.dl-cert.com

Email: [email protected] Page 30 of 35

Shenzhen DL Testing Technology Co., Ltd.

Report No.: DL-20231218049E

Test Report

Tel: 400-688-3552

Web:www.dl-cert.com

Email: [email protected] Page 31 of 35

Shenzhen DL Testing Technology Co., Ltd.

Report No.: DL-20231218049E

Test Report

Tel: 400-688-3552

Web:www.dl-cert.com

Email: [email protected] Page 32 of 35

Shenzhen DL Testing Technology Co., Ltd.

Report No.: DL-20231218049E

Test Report

Tel: 400-688-3552

Web:www.dl-cert.com

Email: [email protected] Page 33 of 35

Shenzhen DL Testing Technology Co., Ltd.

Report No.: DL-20231218049E

Test Report

Tel: 400-688-3552

Web:www.dl-cert.com

Email: [email protected] Page 34 of 35

Shenzhen DL Testing Technology Co., Ltd.

Report No.: DL-20231218049E

 END OF REPORT 

Test Report

Tel: 400-688-3552

Web:www.dl-cert.com

Email: [email protected] Page 35 of 35



Related FCC IDs: