Leo su

RF Exposure

ShenZhen JiGuangXingChen Technology Co., Ltd. KPCS01 STONEGO KPCS01 Bluetooth finder 2BNYB-KPCS01 2BNYBKPCS01 kpcs01

PDF Viewing Options

Not Your Device? Search For Manuals or Datasheets below:


File Info : application/pdf, 6 Pages, 301.34KB

Document DEVICE REPORTGetApplicationAttachment.html?id=8197131
RF EXPOSURE Test Report

Report No.:

MTi241219009-04E2

Date of issue: 2025-01-09

Applicant:

ShenZhen JiGuangXingChen Technology Co., Ltd.

Product name: STONEGO KPCS01

Model(s):

KPCS01

FCC ID:

2BNYB-KPCS01

Shenzhen Microtest Co., Ltd. http://www.mtitest.cn

Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao' an District, Shenzhen, Guangdong, China.

Tel: 0755-88850135-1439 Mobile: 131-4343-1439 (Wechat same number)

Web: http://www.mtitest.cn

E-mail: [email protected]

- Page 2 of 6-

Report No.: MTi241219009-04E2

Instructions
1. The report shall not be partially reproduced without the written consent of the laboratory;
2. The test results of this report are only responsible for the samples submitted; 3. This report is invalid without the seal and signature of the laboratory; 4. This report is invalid if transferred, altered or tampered with in any form
without authorization; 5. Any objection to this report shall be submitted to the laboratory within 15 days
from the date of receipt of the report.

Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao' an District, Shenzhen, Guangdong, China.

Tel: 0755-88850135-1439 Mobile: 131-4343-1439 (Wechat same number)

Web: http://www.mtitest.cn

E-mail: [email protected]

- Page 3 of 6-

Report No.: MTi241219009-04E2

TEST RESULT CERTIFICATION

Applicant's name:

ShenZhen JiGuangXingChen Technology Co., Ltd.

Address:

Room 1-101, Building A, Xintian Pioneer Park, YangGuang Road No.6, BaiMang, Xili Subdistrict, Nanshan District, Shenzhen City, Guangdong Province, China

Manufacturer's Name:

ShenZhen Zoqin Technology C o., Ltd.

Address:

306/308, Building C, Digital Economy Industrial Park, No. 54-6 Guanlan Avenue, Longhua District, Shenzhen

Product description

Product name: Trademark:

STONEGO KPCS01 STONEGO

Model Name:

KPCS01

Serial Model:

N/A

Standards:

part 2.1093

Test procedure:

KDB 447498 D01 v06

Date of Test

Date (s) of performance of tests:

2025-12-30 to 2025-01-09

Test Result:

Pass

Test Engineer : Reviewed By : Approved By :

(James Qin) (David Lee) (Leon Chen)

Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao' an District, Shenzhen, Guangdong, China.

Tel: 0755-88850135-1439 Mobile: 131-4343-1439 (Wechat same number)

Web: http://www.mtitest.cn

E-mail: [email protected]

- Page 4 of 6-

Report No.: MTi241219009-04E2

Table of Contents
1. STANDALONE SAR TEST EXCLUSION CONSIDERATIONS ............................................................................................5 2. SAR TEST EXCLUCSION THRESHOLDS ........................................................................................................................6

Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao' an District, Shenzhen, Guangdong, China.

Tel: 0755-88850135-1439 Mobile: 131-4343-1439 (Wechat same number)

Web: http://www.mtitest.cn

E-mail: [email protected]

- Page 5 of 6-

Report No.: MTi241219009-04E2

1. Standalone SAR test exclusion considerations

Unless specifically required by the published RF exposure KDB procedures, standalone 1-g head or body and 10-g extremity SAR evaluation for general population exposure conditions, by measurement or numerical simulation, is not required when the corresponding SAR Test Exclusion Threshold condition(s), listed below, is (are) satisfied.
These test exclusion conditions are based on source-based time-averaged maximum conducted output power of the RF channel requiring evaluation, adjusted for tune-up tolerance, and the minimum test separation distance required for the exposure conditions.
The minimum test separation distance defined in 4.1 f) is determined by the smallest distance from the antenna and radiating structures or outer surface of the device, according to the host form factor, exposure conditions and platform requirements, to any part of the body or extremity of a user or bystander.
To qualify for SAR test exclusion, the test separation distances applied must be fully explained and justified, typically in the SAR measurement or SAR analysis report, by the operating configurations and exposure conditions of the transmitter and applicable host platform requirements, according to the required published RF exposure KDB procedures.
When no other RF exposure testing or reporting are required, a statement of justification and compliance must be included in the equipment approval, in lieu of the SAR report, to qualify for SAR test exclusion.
When required, the device specific conditions described in the other published RF exposure KDB procedures must be satisfied before applying these SAR test exclusion provisions.
a) For 100 MHz to 6 GHz and test separation distances  50 mm, the 1-g and 10-g SAR test exclusion thresholds are determined by the following:
[(max. power of channel, including tune-up tolerance, mW) / (min. test separation distance, mm)] · [f(GHz)]  3.0 for 1-g SAR, and  7.5 for 10-g extremity SAR, where
 f(GHz) is the RF channel transmit frequency in GHz  Power and distance are rounded to the nearest mW and mm before calculation
 The result is rounded to one decimal place for comparison
 The values 3.0 and 7.5 are referred to as numeric thresholds in step b) below The test exclusions are applicable only when the minimum test separation distance is  50 mm, and for transmission frequencies between 100 MHz and 6 GHz. When the minimum test separation distance is < 5 mm, a distance of 5 mm according to 4.1 f) is applied to determine SAR test exclusion.
b) For 100 MHz to 6 GHz and test separation distances > 50 mm, the 1-g and 10-g SAR test exclusion thresholds are determined by the following (also illustrated in Appendix B):
1) {[Power allowed at numeric threshold for 50 mm in step a)] + [(test separation distance ­ 50 mm)·(f(MHz)/150)]} mW, for 100 MHz to 1500 MHz
2) {[Power allowed at numeric threshold for 50 mm in step a)] + [(test separation distance ­ 50 mm)·10]} mW, for > 1500 MHz and  6 GHz
c) For frequencies below 100 MHz, the following may be considered for SAR test exclusion (also illustrated in Appendix C):
1) For test separation distances > 50 mm and < 200 mm, the power threshold at the corresponding test separation distance at 100 MHz in step b) is multiplied by [1 + log(100/f(MHz))]

Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao' an District, Shenzhen, Guangdong, China.

Tel: 0755-88850135-1439 Mobile: 131-4343-1439 (Wechat same number)

Web: http://www.mtitest.cn

E-mail: [email protected]

- Page 6 of 6-

Report No.: MTi241219009-04E2

2) For test separation distances  50 mm, the power threshold determined by the equation in c) 1) for 50 mm and 100 MHz is multiplied by ½
3) SAR measurement procedures are not established below 100 MHz.
When SAR test exclusion cannot be applied, a KDB inquiry is required to determine SAR evaluation requirements for any SAR test results below 100 MHz to be acceptable.

2. SAR Test Exclucsion Thresholds

We use 5mm as separation distance to calculated.

Bluetooth DTS:

Transmit Frequency
(GHz)

Mode

Measured Power (dBm)

Tune-up power (dBm)

Max tune-up power(dBm)

Result calculation

2.402

-19.53

-19±1

-18

0.016

2.440

GFSK-1M

-19.60

-19±1

-18

0.016

2.480

-19.32

-19±1

-18

0.016

2.402

-19.95

-19±1

-18

0.016

2.440

GFSK-2M

-19.59

-19±1

-18

0.016

2.480

-19.63

-19±1

-18

0.016

Conclusion:

For the max result: 0.016 3.0 1g SAR test exclusion threshold, No SAR is required.

----END OF REPORT----

1g SAR test
exclusion threshold
3
3
3
3
3
3

Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao' an District, Shenzhen, Guangdong, China.

Tel: 0755-88850135-1439 Mobile: 131-4343-1439 (Wechat same number)

Web: http://www.mtitest.cn

E-mail: [email protected]

