INSTALLATION INSTRUCTIONS
Ventilating Fan
Model No. FV-0511VKS3S FV-0511VKS3 FV-0511VK3 FV-1115VK3
Contents
IMPORTANT SAFETY INFORMATION..........................................2-3 PLEASE READ PRIOR TO INSTALLING THIS FAN..........................4 DESCRIPTION..................................................................................4 UNPACKING.....................................................................................4 SUPPLIED ACCESSORIES AND DIMENSIONS............................5-6 WIRING DIAGRAM...........................................................................7 FEATURES........................................................................................7 INDICATIONS (Plug `N PlayTM FUNCTION DEVICES).................8-10 INSTALLATION (Plug `N PlayTM FUNCTION DEVICES).................10 INSTALLATION (CEILING MOUNTING)....................................11-14 INSTALLATION (WALL MOUNTING)........................................14-16 INSTALLATION (RETROFIT).......................................................16-17 MAINTENANCE (CLEANING).....................................................17-18 PRACTICAL GUIDE TO INSTALLATION........................................18 SPECIFICATIONS.......................................................................19-20 PRODUCT SERVICE.......................................................................20

FV-0511VKS3

FV-0511VK3

FV-1115VK3

READ AND SAVE THESE INSTRUCTIONS
Thank you for purchasing this Panasonic product. Please carefully read the section "IMPORTANT SAFETY INFORMATION". Failure to comply with instructions could result in personal injury or property damage. Please explain to users how to operate and maintain the product after installation and present this manual to users. Please retain this manual for future reference.

IMPORTANT SAFETY INFORMATION
For your safety To reduce the risk of injury, loss of life, electric shock, fire, malfunction, and damage to equipment or property, always observe the following safety precautions.
Explanation of symbol word panels The following symbol word panels are used to classify and describe the level of hazard, injury, and property damage caused when the denotation is disregarded and improper use is performed.
WARNING Denotes a potential hazard that could result in serious injury or death.
CAUTION Denotes a hazard that could result in minor injury.

NOTICE

Denotes a hazard that could result in property damage.

The following symbols are used to classify and describe the type of instructions to be observed.

This symbol is used to alert users to a specific operating procedure that must be followed in order to operate the unit safely.

This symbol is used to alert users to a specific operating procedure that must not be performed.

This symbol is used to alert users not to disassemble the equipment.
This symbol is used to alert users to make sure of grounding when using the equipment with the grounding terminal.
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:
Use this unit only in the manner intended by the manufacturer. If you have any questions, contact the manufacturer.
Before servicing or cleaning unit, switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.
Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction.
Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning equipment to prevent backdraft. Follow the heating equipment manufacturer's guideline and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE) and the local code authorities.
When cutting or drilling into wall or ceiling, do not damage electrical wiring or other hidden utilities.
Ducted exhaust fans must always be vented to the outdoors.
If this unit is to be installed over a tub or shower, it must be marked as appropriate for the application and be connected to a GFCI (Ground Fault Circuit Interrupter) protected branch circuit.
Do not use replacement parts that have not been recommended by the manufacturer (e.g. parts made at home using 3D printer).
This product must be properly grounded.
Do not use this unit with any solid-state speed control device. Solid state controls may cause harmonic distortion which can cause a humming noise in the motor.

IMPORTANT SAFETY INFORMATION
Do not disassemble the unit for reconstruction. It may cause fire or electric shock. Install the fan at least 1.5 m (5 feet) above the floor.

CAUTION

Follow all local electrical and safety codes, as well as the National Electrical Code (NEC) and the Occupation Safety and Health Act (OSHA), using UL approved wire nuts. Make sure that the electric service supply voltage is AC 120V, 60Hz. The special-purpose or dedicated parts, such as mounting fixtures, must be used if such parts are provided. Please wear gloves to protect hands during installation.
Do not install this ventilating fan where interior room temperature may exceed 104°F (40°C).
For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors.

Do not kink the supply wiring.
NOTICE

Provide make up air for proper ventilation.

Do not connect multiple units in parallel. If two or more units are connected to one switch in parallel, the unit may not function.
Do not install fan above or inside 45-degree angle projected outwards from the cooking equipment element closest to fan (Fig. A).

Do not install the unit where ducts are configured as shown (Fig. B).

(Cooking area) Do not install above or
inside this area

45°

45°

-Successive bending -Excessive bending

Cooking equipment
Fig. A

Floor

-Squeezed duct -Bend close to duct adaptor Fig. B

3

PLEASE READ PRIOR TO INSTALLING THIS FAN
Continuous ventilation: These fans are designed to run continuously ensuring a healthy environment at low CFM levels 24 hours a day. By utilizing the optional Multi-Speed module, the fans are built to run continuously at a pre-set lower level (FV-0511VKS3S, FV-0511VKS3 and FV-0511VK3: 0, 30, 40, 50, 60, 70, 80, 90, 100 CFM; FV-1115VK3: 0, 50, 60, 70, 80, 90, 100, 110, 120 CFM). The setting is dependent on the size of the house and the individual wishes of the homeowner. It is crucial that the installer pre-sets the lower setting during the installation. Please refer to the chart below and Multi-speed module on page 8.

Custom vent Multi-Speed module (Lower Setting). ASHRAE 62.2-2022

(sq.feet) Two Bedrooms Three Bedrooms Four Bedrooms Five Bedrooms

< 500

38

45

501-1000

53

60

1001-1500

68

75

1501-2000

83

90

2001-2500

98

105

2501-3000

113

120

3001-3500

128

135

3501-4000

143

150

4001-4500

158

165

4501-5000

173

180

53

60

68

75

83

90

98

105

113

120

128

135

143

150

158

165

173

180

188

195

Spot ventilation: These fans are also built to take care of the homeowner's spot ventilation needs when the room is occupied. The basic fan models allow a choice of three speeds. When fans are equipped with the optional Multi-Speed module, these models increase to a maximum level of 150 CFM for the FV-1115VK3 and 110 CFM for FV-0511VKS3S, FV-0511VKS3 and FV-0511VK3 either when the switch is turned on, or activated by the optional Condensation Sensor module (FV-CSVK1) or the optional Motion Sensor module (FV-MSVK1).

A High/Low Delay Timer, located inside the fan unit, is utilized to return the fan back to the pre-set continuous ventilation mode. The installer needs to consult with the homeowner for the desired setting on the timer (0 - 60 minutes) and make the adjustments during the installation.

DESCRIPTION
These products are listed by UL under UL file No. E78414. This product use a sirocco fan driven by a DC motor powered by an integral transformer. The motor is designed to have long operating life, high dynamic response, higher speed ranges and energy savings.The grille covering the fan body is a spring-attached, quick removal type. A damper for preventing air counter flow is provided. The blower uses a high-capacity sirocco fan developed to reduce the noise level.
UNPACKING
Unpack and carefully remove the unit from packing. Refer to the Supplied Accessories list to verify that all parts are present.

4

SUPPLIED ACCESSORIES AND DIMENSIONS
For Models.- FV-0511VKS3, FV-0511VK3, FV-1115VK3

Part name

Appearance Quantity

Part name

Appearance

Quantity

Grille

Warranty sheet &

1

Installation instructions

1

Flex-Z Fast® bracket (with 4 tapping screws -ST4.2X20)
2

Self-drilling screw

1

4 inch duct reducer

(optional part), not included

for FV-1115VK3

1

13 1 1/4 (30)

1 1/2 (37) 4 1/2 (114)

3

4 1 Unit: inches (mm)

Ø 5 7/8 (148) 13 (330)
3 3/8 (86) 13 1/4 ~ 15 1/2 (336~394) 16 1/2 ~ 18 3/4 (419~480) 21 1/4 ~ 23 1/2 (540~597)

12 (304) 10 1/4 (260)

11

3 7/8

(100)

5 9 14 15

12

7 1/2 (190)

4
5 1/8 (130)

6

8

Ø 3 7/8 (100)

10
No Part name 1 Blade 2 Grille 3 Junction box 4 Adapter
Multi-Speed module (FV-0511VKS3 and 5 FV-0511VKS3S only, not included in other
models)
6 Connector cover
4 Inch duct reducer (optional part), 7 not included for FV-1115VK3

7

No Part name 8 Main PCB box
9 Pick-A-Flow® switch
10 Fan body
11 Damper 12 Flex-Z Fast® bracket 13 Power PCB
Motion sensor location (FV-MSVK1, not included), 14 Condensation sensor location (FV-CSVK1, not included)
or Wi-Fi module location (WP100PBA, not included)

15

Motion sensor location (FV-MSVK1, not included), Condensation sensor location (FV-CSVK1, not included)

5

SUPPLIED ACCESSORIES AND DIMENSIONS
For model.- FV-0511VKS3S

Part name

Appearance Quantity

Part name

Appearance Quantity

Grille

Warranty sheet &

1

Installation instructions

1

Flex-Z Fast® bracket (with 4 tapping screws -ST4.2X20)
1 2

1
13 3

Self-drilling screw

4

4 inch duct reducer

1

(optional part)

Unit: inches (mm)

1 1/4 (30)

1 1/2 (37) 4 1/2 (114)

3 3/8 (86) 13 1/4 ~ 15 1/2 (336~394) 16 1/2 ~ 18 3/4 (419~480) 21 1/4 ~ 23 1/2 (540~597)

Ø 5 7/8 (148) 13(330)

12 (304) 10 1/4 (260)

11

5 9 14 15

3 7/8 (100)

12

7 1/2 (190)

4

5 1/8

(130)

6

8

Ø 3 7/8 (100)

10 10 1/4 (261)
No Part name 1 Blade 2 Grille 3 Junction box 4 Adapter
5 Multi-Speed module 6 Connector cover 7 4 Inch duct reducer (optional part)

7

No Part name 8 Main PCB box 9 Pick-A-Flow® switch

10 Fan body 11 Damper

12 Flex-Z Fast® bracket

13 Power PCB Motion sensor location (FV-MSVK1, not included)
14 Condensation sensor location (FV-CSVK1, not included) or Wi-Fi module location (WP100PBA, not included)

15

Motion sensor location (FV-MSVK1, not included) Condensation sensor location (FV-CSVK1, not included)

6

Fan body
DC Motor
Multi-Speed module (FV-0511VKS3, FV-0511VKS3S only, not included in other models) Plug `N PlayTM module slot
Plug `N PlayTM module slot

WIRING DIAGRAM

Junction box Black White
Red Red

Power

switch

Live (Fan)

AC120V

Signal

Neutral

60Hz (Power supply)

switch Use signal switch for manual control of high / low CFM mode: ON to use Pick-A-Flow®

setting (high speed / CFM); OFF to use

Multi-speed module setting (low speed / CFM)

Do not connect the red signal wires to a live power supply (AC 120 V 60 Hz ) because it will damage the product. Please use an optional switch to connect the red signal wires.

Green

Earth ground

FEATURES
Optimum ventilation performance: Duct length, elbows and other factors increase static pressure which can hinder the performance of most ventilation fans. This fan utilizes Smart Flow microchip technology that monitors the static pressure in the system and speeds up or slows down the RPM of the fan depending upon the amount of resistance within the ducts. This feature allows the fan to perform as rated and avoid potential installation issues.
Outstanding Energy Savings: The WhisperGreen Select® line of fans are built using DC motor technology. The DC motor is 30% - 70% more energy efficient than the minimum ENERGY STAR requirements.
Pick-A-Flow® Feature All the WhisperGreen Select® base models of fans come with Pick-A-Flow® speed options. The Pick-A-Flow®switch on the face of all WhisperGreen Select® fans allows the option to choose 50 ­ 80 ­ 110 CFM for the FV-0511VKS3S, FV-0511VKS3, FV-0511VK3 or 110 ­ 130 ­ 150 CFM for the FV-1115VK3. These fans can run continuously or intermittently, depending upon the needs of the owner.

AIR VOLUME (CFM) 0511 50 80 110
MODEL
1115 MODEL110130150
Pick-A-Flow® switch

Model No.
FV-0511VKS3S FV-0511VKS3 FV-0511VK3
FV-1115VK3

Air volume (CFM) Factory setting

50 80 110

80 CFM

110 130 150 130 CFM

7

INDICATIONS (Plug 'N PlayTM FUNCTION DEVICES)

0511 MODEL 1115 MODEL
0511 MODEL 1115 MODEL
FV-VS15VK1 Note.- There is ONLY ONE Plug 'N PlayTM slot to insert the Multi-Speed module.

Plug 'N PlayTM Modular Component Accessories Sold Separately, Not Included With Base Model Fan

FV-VS15VK1 Multi-Speed module allows the fan to run continuously at lower speeds to maintain ventilation standards to meet Indoor Air Quality and then boost up to high speed to meet intermittent needs for `Spot' or `Point Source' exhaust needs. The FV-VS15VK1 Modular Component will operate for both the FV-0511VK3 and the FV-1115VK3 matching the appropriate Multi-Speed setting shown below. Multi-speed module FV-VS15VK1 is included for models FV-0511VKS3S and FV-0511VKS3. It is not necessary to purchase this component. Note the options on the face of the FV-VS15VK1 Multi-Speed module to choose appropriate levels of airflow (CFM) and time delay before returning back to low speed (TIME). Choosing the Pick-A-Flow® setting automatically adjusts the Multi-Speed setting accordingly. As an example, if the Pick-A-Flow®Multi-speed setting is 80 CFM, the Multi-Speed settings adjust automatically to be 0, 30, 40, 50, 60 or 70 CFM at the lower speeds. The fan will `boost' to the 80 CFM speed as the high speed setting. Selecting a particular TIME option will cause the fan to run for the selected amount of time before returning to the lower speed setting chosen on the CFM dial.

Model no

Pick-A-Flow®(CFM)

Multi-Speed Air volume (CFM)

FV-0511VKS3S,

50

FV-0511VKS3

FV-0511VK3

80

(plug-in FV-VS15VK1)

110

110

FV-1115VK3 (plug-in FV-VS15VK1)

130

150

0 30 40 40 40 40 40 40 40
0 30 40 50 60 70 70 70 70 0 30 40 50 60 70 80 90 100 0 50 60 70 80 90 100 100 100 0 50 60 70 80 90 100 110 110 0 50 60 70 80 90 100 110 120

FV-CSVK1
Note.- There are TWO Plug 'N PlayTM slots to insert the condensation module.See page 10 for details.

Delay Time (min)
Factory setting: 20 minutes. Delay Time position "0": Manual wall switch control is 0 minutes; without manual wall switch control is 0.5 minutes.
FV-CSVK1 Condensation Sensor module turns the base fan on or boosts to higher speed when humidity is detected when used in combination with the FV-VS15VK1. The Condensation Sensor works based on calculations from the Psychrometric Chart, or combination of Relative Humidity (RH) and Temperature. This allows the fan to anticipate the formation of condensation and automatically turn ON when needed to expel humid air. The Condensation Sensor is pre-set to run for 20 minutes; it will then check the RH and Temperature to detect if the fan needs to run for another 20 minutes cycle.

This product can set air volume by Pick-A-Flow® switch, set humidity by the induction humidity setting switch, and operate as below.

Power

ON

OFF

switch

Signal switch

OFF

ON

Condensation sensor

Humidity setting About 5 % RH

Product

Environment humidity

Delay

Run

operation

Stop

Run

Stop

Stop

Induction humidity setting switch

AIR VOLUME (CFM) 0511 50 80 110
MODEL
1115 MODEL110130150
Pick-A-Flow ® switch

2 The product will continue to run for about 20 minutes until it detects the environment humidity is about 5% RH lower than the humidity setting, then it will stop running. Note: 1. When the humidity sensor is used in combination with the multi-speed, the delay time can be selected as needed. 2. The product will start running when the environment humidity rises rapidly (even if the humidity set point is not reached yet) and will stop after 20 minutes. 3. Induction humidity setting switch is stepless change between 30 %RH ~ 80 %RH. 4. The humidity detected by sensor may differ from the value on your hygrometer. 5. The product may turn ON and OFF due to the unstable environment humidity, but it can be improved by adjusting the Humidity setting selector.

8

INDICATIONS (Plug 'N PlayTM FUNCTION DEVICES)
FV-MSVK1 Motion Sensor module turns the base fan on or boosts to higher speed when motion is detected when used in combination with the FV-VS15VK1. The Motion Sensor is pre-set to run for 20 minutes; it will then re-check for movement; if detected, the fan will run for another 20 minutes cycle. The Motion
0511 MODEL 1115 MODEL
Sensor detects within the range shown below.
The distance that motion can be detected is limited to 10 feet (3 m). The field of view of the sensor is 90º. Room temperature is 77 ºF (25 ºC).

Note.- There are TWO Plug 'N PlayTM slots to insert the motion sensor module. See page 10 for detail.

WP100PBA Swidget® Wi-Fi control module

Wi-Fi Plug 'N PlayTM features · Wireless Plug 'N PlayTM control module for Panasonic WhisperGreen Select®. · Connect and control Panasonic ventilation products with the Swidget iOS or Android app through 2.4 GHz Wi-Fi. · Connect, group and balance Panasonic ventilation products with a dedicated Swidget commissioning iOS or Android application through Bluetooth 5.0 mesh.

SCAN QR CODE FOR Wi-Fi MODULE'S INSTRUCTION
OR VISIT WEB SITE

Swidget app features · Control the boost mode of all compatible Panasonic ventilation products with an always-ON or 20-40-60 minute timer. · Control the light module and view the motion and condensation module status of compatible Panasonic WhisperGreen Select® models. · View the supply air and exhaust air CFM, temperature and humidity of compatible Panasonic ventilation products. · Receive notifications for faults, filter replacement and filter cleaning for compatible Panasonic ventilation products. · Monitor the energy consumption of compatible Panasonic ventilation products.
NOTICE

http://WP100PBA-QR.swidget.com www.swidget.com

This module must only be installed and used with an approved/certified Swidget wiring device. Usage with any other devices is not permitted and will result in the warranty becoming void.

WARNING

· While not required, it is recommended to avoid any risk of shock or death, turn off power at the circuit breaker or fuse and test that the power is off before installing or removing any module. · Not for use to control medical or life support equipment. · For INDOOR use only: 0°C - 40°C (32°F - 104°F). · Module can only be installed in one orientation. Rear alignment pins prevent incorrect installation. Do not forcibly install an module. · Requires a wireless router and Internet connection for device setup. · Double check any external Wi-Fi settings for accuracy before using them. · Actual wireless performance in a home depends on the numbers of walls / obstacles between the module and wireless router.

9

INDICATIONS (Plug 'N PlayTM FUNCTION DEVICES)
The Plug 'N PlayTM modules can be used in combination, in order to adapt the fan operation to the user's needs. Please refer to the table below for details.

Plug 'N PlayTM modules combination

Fan operation with Plug 'N PlayTM modules' combinations

Step 1) Not detected

Step 2) Sensor trigger detection Motion OR Condensation

Step 3) Not detected

Empty

Inside

Outside

When motion is not detected, the fan runs on low speed.(2)
FV-MSVK1 + FV-VS15VK1

FV-CSVK1 + FV-MSVK1

When humidity is about 5% R. H. below the set point AND motion is not detected, the fan stays OFF.

When humidity is below the set point, the fan runs on low speed.(2)
FV-CSVK1 + FV-VS15VK1

Boosts the fan to high speed when motion is detected.

The fan will automatically return to low speed(2)after the set delay time.

Turns the fan ON for 20 minutes when motion is detected OR humidity is about 5% R. H. above the set point.

The fan will run on high speed until humidity decreases to about 5% R. H. below the set point AND 20 minutes afterwards, the fan will automatically turn OFF.

Boosts the fan to high speed when humidity is about 5% R. H. above the set point.

The fan will run on high speed until humidity decreases to about 5% R. H. below the set point AND, after the set delay time has passed, it will automatically return to low speed.(2)

(2) When the low speed is set to 0 CFM on the multi-speed module, the fan stops running.

INSTALLATION (Plug 'N PlayTM FUNCTION DEVICES)
You can purchase the specified Plug 'N PlayTM device which are explained on page 8 through 11 and installed as described on page 10 (Fig. 2).

1. Remove the corresponding connector cover (Fig. 1).
Squeeze tabs on the clasp to remove. Squeeze, insert and release the tabs on clasp to replace.

2. Plug in corresponding module to main PCB box and fix to the slot. Make sure the connector connects well (it will click when installed in place) (Fig. 2).

Connector cover

Clasp

Main PCB box

(Fig. 1)

3 FV-MSVK1 or FV-CSVK1
2 FV-MSVK1 or FV-CSVK1 or WP100PBA

Connector

FV-VS15VK1

(Fig. 2)

10

INSTALLATION (CEILING MOUNTING)

WARNING
1. Disconnect power supply before installing the unit. 2. Please wear gloves to protect hands during the installation.

ATTENTION Remove the tape and accessory from the adapter, before installation.

Damper

Adapter

Tape

4" reducer (Not applicable for FV-1115VK3)

Remove adapter plate

Adapter

Duct tape

PRESS

Receptacle

Machine screw (M4X8)

Hook

Plug
Disconnect the plug from the receptacle. Remove the M4X8 machine screw.

Fan body

Guide Parts
Press the hook and slide the adapter out of the fan body.

Install Flex-Z Fast® bracket
The Flex-Z Fast® bracket position can be adjusted from 16" to 24" between joists.

Joist

Joist

Align

Flex-Z Fast®bracket

EXTEND

2 Tapping screws (ST4.2 X 20)

2 Tapping screws (ST4.2 X 20)

Bend down 4 tabs and align bracket to the joist.
Align and install bracket to joist by using the 2 pre-installed tapping screws.

Extend bracket to the other joist.
Install bracket to joist by using 2 pre-installed tapping screws.

Install circular exhaust duct
Screw

Remove junction box cover and secure conduit or stress relief to junction box knock-out hole.

Conduit

Install the circular exhaust duct and secure it with clamps or ties and seal it with mastic or approved foil tape. A 4 or 6 inch circular duct is needed to connect to the relevant part of the adapter.
Install the adapter to Flex-Z Fast® bracket by using 2 self-drilling screws.

Knock-out hole
Junction Box cover

Circular exhaust duct
Mastic or approved foil tape

2 Self-drilling screws

11

INSTALLATION (CEILING MOUNTING)

Wiring diagram

CAUTION

Live Fan

Neutral

1. Mount junction box cover carefully so that lead wire are not pinched.
AC 120 V 60 Hz (Power supply)

Earth ground

Red wires wire nuts

Earth ground Neutral Live

Signal switch

White

Switch box

Conduit

A A

Green Red

Black

Refer to WIRING DIAGRAM (Page 7). Follow all the local electrical safety codes as well as the National Electrical Code (NEC), using UL approved wire connectors to connect fan wires.
Insert fan body

Joist

Joist

Hook

Guide Parts

Insert body and slide it into the adapter assembly until you hear a click from the hook.

6 Secure fan body Receptacle Plug CAUTION

1. Secure machine screw (M4X8) to the suitable hole and not touch the Flex-Z Fast bracket. Please fix the screw carefully to avoid damaging the screw thread.

Machine screw (M4X8)

Flange 2 Self-drilling screws

When the flange overlaps the Flex-Z Fast bracket, secure fan body using two self-drilling screws.

Plug connector into receptacle and secure fan body to adapter by using machine screw (M4X8).

12

INSTALLATION (CEILING MOUNTING)

7 Sealing
Finish ceiling work. Ceiling hole should be aligned with the inside edge of flange.
Once fan body is mounted and secure, fill gap between flange and ceiling with caulk or other sealant to prevent air leakage.

10 1/2 (266)

10 1/2 (266)

Ceiling

Unit: inches (mm)

8 Install grille
A) INSTALL GRILLE FOR MODELS FV-0511VKS3, FV-0511VK3, FV-1115VK3
Insert the mounting spring into the slot as shown to mount grille to fan body.
Fix the motion sensor into grille. Adjust Pick-A-Flow® switch and multi-speed selector (only models FV-0511VKS3S, FV-0511VKS3) as desired. Refer to indication on "FEATURES" section, page 7and 8. Fix motion sensor cables in the indicated hooks.
Insert the other mounting spring into the slot as shown and mount grille to fan body.
Pick-A-Flow®

CAUTION
The claw of connector must latch the rib completely. Mount grille carefully so that lead wire is not pinched.
ATTENTION: When the switch is at the "ON" position, wait 8-10 seconds for the fan to start. This is a normal working condition.
Ceiling
Mounting spring

Ceiling

Mounting spring

Clasps

Grille

Gloves

Motion sensor (FV-MSVK1 only, not included)
A Keep on pressing the clasps when removing the ornamental cover.
Gloves

IMPORTANT:
Replace the sensor cover before the installation (only for plug-in Motion sensor module FV-MSVK1). NOT INCLUDED (Fig. 10).

B

Position shorter tabs on these sides

Ornamental cover

Sensor cover
Fig.9
13

INSTALLATION (CEILING MOUNTING)

b) INSTALL GRILLE FOR MODEL FV-0511VKS3S Note: Before installing the grill for model FV-0511VKS3S follow the steps 1 through 8 (P.11 to 13).
Insert the mounting spring into the slot as shown to mount grille to fan body.

Pick-A-Flow® Ceiling

Fix the motion sensor into grille.
Adjust Pick-A-Flow® switch and multi-speed selector (only models FV-0511VKS3S, FV-0511VKS3) as desired. Refer to indication on "FEATURES" section, page 7 and 8.
Fix motion sensor cables in the indicated hooks.

Mounting spring

Insert the other mounting spring into the slot as shown and mount grille to fan body.

Ceiling

Clasp
Motion sensor (FV-MSVK1 only, not included) Mounting spring

IMPORTANT: Replace the sensor cover before the installation (only for plug-in Motion sensor module FV-MSVK1). NOT INCLUDED (Fig. 10).
A Keep on pressing the clasps when removing the ornamental cover.
Gloves

Grille

Gloves

B

Position shorter tabs on these sides

Ornamental cover

INSTALLATION (WALL MOUNTING)

WARNING

ATTENTION Remove the tape and accessory from the adapter, before installation.

1. Disconnect power supply before installing the unit. 2. Please wear gloves to protect hands during the installation.

Damper

Adapter

Tape

4" reducer (Not applicable for FV-1115VK3)

Remove adapter plate

Adapter

PRESS

Receptacle

Machine screw (M4X8)

Hook

Sensor cover
Fig.10
Duct tape

Plug
Disconnect the plug from the receptacle.
Remove the M4X8 machine screw.

Fan body

Guide Parts

Press the hook and slide the adapter out of the fan body.

14

INSTALLATION (WALL MOUNTING)
Install Flex-Z Fast bracket
The Flex-Z Fast bracket position can be adjusted from 16" to 24" between studs.

Align

Extend

® Flex-Z Fast bracket

Stud

Stud

Bend down 4 tabs

2 Tapping screws (ST4.2X20)

Bend down 4 tabs and align bracket to the stud. Align and install bracket to stud by using 2-preinstalled tapping screws.
Install circular exhaust duct

Remove junction box cover and secure conduit or stress

Knock-out hole

relief to junction box knock-out hole.

Install the circular exhaust duct and secure it with clamps or ties and seal it with mastic or approved foil tape. A 4 or 6 inch circular duct is needed to connect to the relevant part of the adapter.

Install the adapter to Flex-Z Fast bracket by using 2 self-drilling screws.

Complete the wiring; please refer to step 4 on page 12.

Junction Box cover

2 Tapping screws (ST4.2X20)

Extend bracket to the other stud.
Install bracket to stud by using 2-preinstalled tapping screws.

CAUTION

1. The adapter of product must be installed upward.

Conduit

Circular exhaust duct

Mastic or approved foil tape

2 Self-drilling screws

Insert and secure fan body

Hook

Receptacle

Plug connector

Flange

Machine screw (M4X8)

2 Self-drilling screw

Guide Parts
15

INSTALLATION (WALL MOUNTING)
Insert the body and slide it into the adapter assembly until you hear a click from the hook.
Secure the fan body to Flex-Z Fast bracket by using 2 self-drilling screws.
Secure fan body and plug connector to adapter by using machine screw (M4X8). To finish wall work and install grille, please refer to steps 7 and 8 (p. 13).

INSTALLATION (RETROFIT)

WARNING

ATTENTION Remove the tape and accessory from the adapter, before installation.

1. Disconnect power supply before installing the unit. 2. Please wear gloves to protect hands during the installation.

Damper

Adapter

Tape

4" reducer (Not applicable for FV-1115VK3)

Duct tape

Remove the existing fan and cut opening

Existing conduit Existing duct

Joist or stud Drywall

Existing Wires

Marker

Existing ceiling or wall

Template

10 7/8" (275) 10 7/8" (275)

Unit: inches (mm)
Marked line

Remove the existing fan, leaving the existing ductwork and wiring in place.

Using housing masking template to mark the ceiling or wall opening, cut the ceiling or wall along the marked line.

Install Flex-Z Fast® bracket
The Flex-Z Fast® bracket position can be adjusted from 16" to 24" between joists or studs.

®
Flex-Z Fast bracket

Joist or stud

Flex-Z Fast® bracket

Joist or stud

Align

®
Insert Flex-Z Fast bracket.
Align and install bracket to joist or stud by using the 2 pre-installed tapping screws.

2 Tapping screws (ST4.2 X 20)

EXTEND

Extend bracket to the other joist or stud.
Install bracket to joist or stud by using 2 pre-installed tapping screws.
16

INSTALLATION (RETROFIT)

Install circular exhaust duct and conduit

Existing conduit

Existing duct

Knock-out hole

Screw

Junction box cover

Junction box

Pull down

Existing wires

Existing ceiling

Before connecting the circular duct to the adapter and conduit to junction box, pull down the circular duct and conduit from the ceiling or wall.

Existing conduit

Before removing knock-out hole and junction box cover Following step 1 "Remove adapter plate" on ( P. 11)

Junction box

Mastic or approved foil tape Adapter plate

2 Self-drilling screws

Install the circular exhaust duct and secure it with clamps or ties and seal it with mastic or approved foil tape. A 4 or 6 inch circular duct is needed to connect to the relevant part of the adapter. Secure conduit and connect wires. Refer to wiring diagram on page 13.

Install the adapter to Flex-Z Fast bracket by using 2 self-drilling screws.
Finish installation process following steps 5 through 8 (P. 13 to P. 14).

MAINTENANCE (CLEANING)

CAUTION

1.- Routine maintenance must be done every year. Please wear gloves during the cleaning work.
2.- Never use gasoline, benzene, thinner or any other such chemicals for cleaning the ventilating fan.

3.- Do not immerse motor in water when cleaning.

Do not soak resin parts in water over 140 °F (60 °C).

Ceiling

4.- Do not use cleaning sprays, solvent, or water on

or near the sensors.

Remove grille

WARNING
1.-Disconnect power supply before working on unit.
2
Clasp

1
Mounting spring

Mounting spring

Ceiling
Grille Gloves
1 Remove grille by pulling down one
mounting spring.

Motion sensor (FV-MSVK1 only, not included)
2 Remove the lead wire of sensor unit from the clasp
(2 point), remove the sensor unit from the grille.
17

MAINTENANCE (CLEANING) Maintenance of unit
Drywall

1

Gloves

Vacuum cleaner
2

Gloves
3

NOTE : The grille should be dry after cleaning.

1 Clean grille. (Don't put into hot water. Use non-abrasive kitchen detergent, wipe dry with clean cloth.)

2 Remove dust and dirt from fan body using a vacuum cleaner.

3 Using a cloth dampened with kitchen detergent, remove any dirt from fan body. Wipe dry with a clean cloth.
Reinstall grille after finishing.

PRACTICAL GUIDE TO INSTALLATION

1. The ducting has a strong effect on the air flow, noise and energy use of the fan. Use the shortest, straightest duct routing possible for best performance, and avoid installing the fan with smaller ducts than recommended. Insulation around the ducts can reduce energy loss and inhibit mold growth. Fans installed with existing ducts may not achieve their rated airflow.
2. A circular 6-inch duct is recommended for best performance and proper fan installation.
3. Ensure duct joints and exterior penetrations are sealed with caulk or other similar material to create an airtight path and to minimize building heat loss and gain and reduce the potential for condensation.
4. Place / wrap insulation around duct and / or fan in order to minimize possible condensation buildup within the duct, as well as minimize building heat loss and gain.

-4 inch or 6 inch roof jack, wall cap, or soffit vent with backdraft damper
-2-3 ft straight run before elbow

-Mechanically connect duct to termination and seal with mastic or approved foil faced tape* /

-In attic installation, caulk box to drywall*

-Insulation

-Short piece of flexible duct helps alignment and absorbs sound*

-Foil tape tightly covers all metal duct joints* -*Seal with mastic or approved foil faced tape

18

SPECIFICATIONS

Specifications for base model fans

Model No.

Air direction

Voltage (V)

Frequency (Hz)

Duct diameter (inches)

FV-0511VK3 FV-0511VKS3

Exhaust

120

60

4

FV-0511VKS3S Exhaust 120

60

Air volume at 0.1" WG
(CFM)
110 80 50 110 80 50

Noise (sones)
<0.3 <0.3 <0.3 <0.3 <0.3 <0.3

Speed (rpm)
782 684 630 829 726 645

Model No.

Air direction

Voltage (V)

Frequency (Hz)

Duct diameter (inches)

FV-0511VK3 FV-0511VKS3

Exhaust

120

60

FV-0511VKS3S Exhaust 120

60

6

FV-1115VK3 Exhaust 120

60

Air volume at 0.1" WG
(CFM) 110 80 50 110
80 50 150
130 110

Noise (sones)
<0.3 <0.3 <0.3 <0.3
<0.3 <0.3 <0.3 <0.3 <0.3

Performance based on HVI procedures 915, 916 and 920 Specifications for Multi-Speed fans

Model No. FV-0511VK3 FV-0511VKS3
FV-0511VKS3S

Air direction

Voltage (V)

Frequency (Hz)

Duct diameter (inches)

Exhaust 120

60

4

Exhaust 120

60

4

Air volume at 0.1" WG
(CFM)
100 90
80 70 60 50 40 30 0 100 90 80 70 60 50 40 30 0

Noise (sones)
<0.3 <0.3 <0.3 <0.3 <0.3 <0.3 <0.3 <0.3
<0.3 <0.3 <0.3 <0.3 <0.3 <0.3 <0.3 <0.3

Speed (rpm)
595 569 575 641 601 577 680 638 595
Speed (rpm)
747 714 684 672 654 630 619 606
783 751 726 708 677 645 617 612

Power (W)
Fan
9.7 5.6 3.8 10.7 6.2 4.0
Power (W)
Fan
6.7 4.4 3.4 7.4 4.7 3.4 11.6 8.8 6.7

Weight lb. 9.7 (4.4)
9.9 (4.5) Weight lb. 9.7 (4.4)
9.9 (4.5)
9.5 (4.3)

Power (W)
Fan
7.8 6.6 5.6 5.1 4.4 3.8 3.4 2.9 1.0 8.3 7.1 6.2 5.4 4.7 4.0 3.3 3.0 1.0

Weight lb. 9.7 (4.4)
9.9 (4.5)

19

SPECIFICATIONS

Model No. FV-0511VK3 FV-0511VKS3
FV-0511VKS3S
FV-1115VK3

Air Voltage Frequency

direction (V)

(Hz)

Exhaust 120

60

Exhaust 120

60

Exhaust 120

60

Duct diameter (inches)
6

Air volume at 0.1" WG
(CFM)
100 90 80 70 60 50 40 30 0
100
90 80 70
60 50 40 30 0
120 110 100 90 80 70 60 50
0

Noise (sones)
<0.3 <0.3 <0.3 <0.3 <0.3 <0.3 <0.3 <0.3
<0.3 <0.3 <0.3 <0.3 <0.3 <0.3 <0.3 <0.3
<0.3 <0.3 <0.3 <0.3 <0.3 <0.3 <0.3 <0.3

Speed (rpm)
580 572 569 565 570 575 563 587
629 620 601 592 590 577 577 585
626 595 580 572 569 565 570 575

Power (W)
Fan
5.5 4.9 4.4 4.0 3.6 3.4 3.0 2.8 1.0 6.2 5.4 4.7 4.3 3.9 3.4 3.1 2.9 1.0
7.5 6.7 5.5 4.9 4.4 4.0 3.6 3.4 1.0

Reference performance based on HVI procedures 915, 916 and 920. [ ( ) Stand by wattage)

Weight lb. 9.7 (4.4)
9.9 (4.5)
9.5 (4.3)

PRODUCT SERVICE
Warning Concerning Removal of Covers. The unit should be serviced by qualified technicians only. Your product is designed and manufactured to ensure a minimum of maintenance. Should your unit require service or parts, call Panasonic Call Center at 1-866-292-7299 (USA) or 1-800-669-5165 (Canada).

Panasonic Corporation of North America
Two Riverfront Plaza, Newark, NJ 07102 www.panasonic.com
Panasonic Corporation 2024

Panasonic Canada lnc.
5770 Ambler Drive, Mississauga, Ontario L4W 2T3 www.panasonic.ca
20 P0324-0 15VK30420

