Maximum Permissible Exposure
RF Exposure Info
ZAGG Inc. ZKPIB13 Pro Keys 2 QTG-ZKPIB13 QTGZKPIB13 zkpib13
Not Your Device? Search For Manuals or Datasheets below:
File Info : application/pdf, 1 Pages, 228.44KB
Document DEVICE REPORTGetApplicationAttachment.html?id=7635629FCC ID: QTG-ZKPIB13 RF exposure evaluation §2.1093 Radiofrequency radiation exposure evaluation: Portable Devices. According to§15.247(i) and§1.1307b(1), systems operating under the provisions of this section shall be operated in a manner that ensures that the public is not exposed to radio frequency energy level in excess of the commission's guidance. The 1-g SAR test exclusion thresholds for 100 MHz to 6 GHz at test separation distances 50 mm are determined by: [(max. power of channel, including tune-up tolerance, mW) / (min. test separation distance, mm)] · [f(GHz)] 3.0 for 1-g SAR, where f(GHz) is the RF channel transmit frequency in GHz Power and distance are rounded to the nearest mW and mm before calculation When the minimum test separation distance is < 5 mm, a distance of 5 mm according is applied to determine SAR test exclusion. The result is rounded to one decimal place for comparison GFSK Frequency Modulation (GHz) Max. Power (dBm) Tune up Power (dBm) Max. Tune up Power (dBm) Max. Tune up Power (mW) Test distance (mm) Result exclusion thresholds for 1-g SAR GFSK 2.402 -1.27 -2±1 -1 0.79 5 0.245 3.0 Conclusion: For the max result : 0.245W/Kg FCC Limit 3.0 for 1g SAR.
Related FCC IDs: