R.M.04.01.PTH.10D-00-02 PTH-10D 中性 英文说明书231204coco客户专用

User Manual (PDF)

Pildegro 3-in-1 Portable Carbon Monoxide Detector, Professional Rechargeable Real-Time Travel CO Monitor 120HR Standby, Premium Reliable CO Detector with Loud Alarm for Air Safety (Green/Vitality)

3-in-1 Portable Carbon Monoxide Detector, Professional Rechargeable Real-Time Travel CO Monitor 120HR Standby, Premium Reliable CO Detector with Loud Alarm for Air Safety (Grey/Courage)

‎PTH-10D User Manual (PDF) Pildegro ‎Pildegro 3-in-1,Portable,Carbon,Monoxide,Detector,Professional,Rechargeable,Real-Time,Travel,CO,Monitor,120HR,Standby,Premium,Reliable,CO,Detector,with,Loud,Alarm,for,Air,Safety,(Grey/Courage),B0CSNK31H2,B0CFPNDYWV

User Manual for Pildegro models including: PTH-10D 3 in 1 Portable Carbon Monoxide Detector, PTH-10D, 3 in 1 Portable Carbon Monoxide Detector, Portable Carbon Monoxide Detector, Carbon Monoxide Detector, Monoxide Detector, Detector

PDF Viewing Options

Not Your Device? Search For Manuals or Datasheets below:


File Info : application/pdf, 1 Pages, 2.98MB

Document DEVICE REPORTB1dk2GtbqUL
EN Air Detector

PTH-10D

Specification
Carbon Monoxide: 0~500 ppm (± 10%) CO Sound Alarm Range: default, 50 ppm Temperature: -10 ~ 50 (± 1.5°C) / 14°F ~ 122°F (± 2.7°F) Humidity: 0% ~ 95% RH (±5%) Battery: Built-in polymer lithium-ion battery (3.7V, 1000mAh) Input: Type-CDC 5V ~ DC 24V (Max), support the fast charging protocol with a power of 10 ~ 65W Fast charging protocol: QC2.0, PD3.0, AFC, USB C UFP (BC1.2 DCP CDP SDP) and other common fast charging protocols (1C) charging Executive Standard: JJG915-2008 Storage Temperature: -20 ~ 60 / -4°F ~ 140°F Product Size: 76mm × 70mm × 30mm (2.99 in × 2.75 in × 1.18 in) Packing List: PTH-10D × 1Type-C Cable × 1Outdoor Special Rope Buckle × 1Users Manual × 1
Warning
This device belongs to a non household level alarm and is not a security product. The CO measurement function and CO Sound Alarm Range provided by it are for reference only and cannot be used as the only standard. In the course of daily use, we should pay attention to safety and maintain good ventilation at all times to avoid danger!
EN 01

Product validity verification

BiBiBi......

BiBiBi......

1. Place the product near the exhaust pipe of a starting fuel vehicle, and detect the CO concentration value of the fuel incomplete combustion. 2. Place the product in a sealed container with burning paper, and detect the CO concentration value of the material incomplete combustion.  Please note that the primary component of natural gas is methane. While this product can detect CO concentration in cases of incomplete combustion and provide alerts, it is not designed for direct detection of natural gas.
EN 02

Product Introduction

Screen display and button Hole For Rope Buckle

CO Concentration

Temperature

Humidity

Buzzer Alert

Battery Capacity

Function Button

Green

Light Indication Alert

EN 03

Yellow Yellow

Red Red

Air Vent

Input Port

Sound Alert Temperature and humidity sensor

Light Indication Alert
When the concentration of CO is 0 ~ 49 ppm, green area flashes, indicating that the CO concentration is at a low level.

Green

Note: The display change of the color indicator bar is based on the CO concentration data.

When the concentration of CO is more than 100 ppm, red area flashes, indicating that the CO concentration is at a dangerous level with alarm sound.
EN

When the concentration of CO is 50 ~ 99 ppm, yellow area flashes, indicating that the CO concentration is at a warning level with alarm sound.
04

Operation
Press function button

Switch °C / 

Press

°C



If there is no keystroke operation within 5 minutes, the device automatically enters power-saving mode. Press function button to wake up it.

Long press function button

Power on

Long

Bi

Press

Power off

EN 05

Customize Sound Alarm Value
Double-click function button to enter setting mode.

Set single digit
Press function button to adjustment value.

Long press function button to confirm and exit.

Long press function button to confirm and adjust number of digits.
Press function button to adjustment value.

Set ten, hundred figures
 During the setting process, there is no keystroke operation within 15 seconds, and the device automatically confirms the current setting operation and exits.
For your safety, the range that can be set is: 25-125(Please refer to page 08 for the settings of the two modes)
EN 06

 When the device sounds an audible alarm, you can press the function button to pause it for 15 seconds. After 15 seconds, if the ambient carbon monoxide concentration still exceeds the standard, the buzzer will sound again until the carbon monoxide level is lower than the alarm value.
BiBiBi......
 When you use this device in outdoor scenes (such as camping, car, etc.), for safety reasons, it is recommended that you set the alarm value between 25 and 75 ppm.
Warning
When the device sounds an audible alarm, please open the window for ventilation as soon as possible, find the source at the same time, and cut it off.
EN 07

Outdoor sound alarm mode and indoor sound alarm mode

Outdoor sound alarm mode

Indoor sound alarm mode

Custom sound alarm value is set between 25 and 75 ppm.

Custom sound alarm value is set between 75 and 125 ppm.

This mode is suitable for outdoor scenes (camping, car, etc.)

This mode is suitable for indoor scenes (kitchen, bedroom, etc.)

The carbon monoxide concentration exceeds the custom alarm value you set, and the sound alarm emits a low-frequency alarm sound of "beep--,beep--,beep--".

The carbon monoxide concentration exceeds the custom alarm value you set, and the sound alarm emits a low-frequency alarm sound of "beep--,beep--,beep--".

The concentration of carbon monoxide continues to rise, and when it exceeds 100 ppm, the audible alarm emits a high-frequency alarm sound of "beep, beep, beep..."

The concentration of carbon monoxide continues to rise, and when it exceeds 150 ppm, the audible alarm emits a high-frequency alarm sound of "beep, beep, beep..."

EN 08

Note
 Do not expose this product to water and dust, nor place it in a high temperature environment exceeding 60°C, and keep it away from fire.  The device is a precision measuring instrument, and it is not allowed to disassemble it without authorization.  The charging cable and charging plug must support the relevant fast charging protocol at the same time in order to realize fast charging.  When charging, due to the heating of the charging circuit and the battery, the temperature and humidity value may be 3°C ~ 5°C higher than the normal value. To obtain an accurate temperature and humidity measurement value, please read it after the device cools down to room temperature.  If you want to stay out of use for a long time, please charge the device first, then turn it off and put it away.  Endorsed by authoritative certifications from both China and the United States: 1.CNAS: China National Accreditation Service for Conformity Assessment LABORATORY ACCREDITATION CERTIFICATE (Registration No: CNAS L16927) 2.UL 217:January 2,2020 Standard for Safety Smoke Alarms; NO: HPT-230705L0112S 3.UL 2034: March 31, 2017 UL Standard for Safety Single and Multiple Station Carbon Monoxide Alarms; NO: HPT-230705L0109S
FR
Made in China
EN 09


Adobe PDF library 16.07 Adobe Illustrator(R) 24.0