R.M.04.01.PTH.10D-00-02 PTH-10D 中性 英文说明书231204coco客户专用
User Manual (PDF)
Pildegro 3-in-1 Portable Carbon Monoxide Detector, Professional Rechargeable Real-Time Travel CO Monitor 120HR Standby, Premium Reliable CO Detector with Loud Alarm for Air Safety (Green/Vitality)
3-in-1 Portable Carbon Monoxide Detector, Professional Rechargeable Real-Time Travel CO Monitor 120HR Standby, Premium Reliable CO Detector with Loud Alarm for Air Safety (Grey/Courage)
PTH-10D User Manual (PDF) Pildegro Pildegro 3-in-1,Portable,Carbon,Monoxide,Detector,Professional,Rechargeable,Real-Time,Travel,CO,Monitor,120HR,Standby,Premium,Reliable,CO,Detector,with,Loud,Alarm,for,Air,Safety,(Grey/Courage),B0CSNK31H2,B0CFPNDYWV
User Manual for Pildegro models including: PTH-10D 3 in 1 Portable Carbon Monoxide Detector, PTH-10D, 3 in 1 Portable Carbon Monoxide Detector, Portable Carbon Monoxide Detector, Carbon Monoxide Detector, Monoxide Detector, Detector
Not Your Device? Search For Manuals or Datasheets below:
File Info : application/pdf, 1 Pages, 2.98MB
Document DEVICE REPORTB1dk2GtbqULEN Air Detector PTH-10D Specification Carbon Monoxide: 0~500 ppm (± 10%) CO Sound Alarm Range: default, 50 ppm Temperature: -10 ~ 50 (± 1.5°C) / 14°F ~ 122°F (± 2.7°F) Humidity: 0% ~ 95% RH (±5%) Battery: Built-in polymer lithium-ion battery (3.7V, 1000mAh) Input: Type-CDC 5V ~ DC 24V (Max), support the fast charging protocol with a power of 10 ~ 65W Fast charging protocol: QC2.0, PD3.0, AFC, USB C UFP (BC1.2 DCP CDP SDP) and other common fast charging protocols (1C) charging Executive Standard: JJG915-2008 Storage Temperature: -20 ~ 60 / -4°F ~ 140°F Product Size: 76mm × 70mm × 30mm (2.99 in × 2.75 in × 1.18 in) Packing List: PTH-10D × 1Type-C Cable × 1Outdoor Special Rope Buckle × 1Users Manual × 1 Warning This device belongs to a non household level alarm and is not a security product. The CO measurement function and CO Sound Alarm Range provided by it are for reference only and cannot be used as the only standard. In the course of daily use, we should pay attention to safety and maintain good ventilation at all times to avoid danger! EN 01 Product validity verification BiBiBi...... BiBiBi...... 1. Place the product near the exhaust pipe of a starting fuel vehicle, and detect the CO concentration value of the fuel incomplete combustion. 2. Place the product in a sealed container with burning paper, and detect the CO concentration value of the material incomplete combustion. Please note that the primary component of natural gas is methane. While this product can detect CO concentration in cases of incomplete combustion and provide alerts, it is not designed for direct detection of natural gas. EN 02 Product Introduction Screen display and button Hole For Rope Buckle CO Concentration Temperature Humidity Buzzer Alert Battery Capacity Function Button Green Light Indication Alert EN 03 Yellow Yellow Red Red Air Vent Input Port Sound Alert Temperature and humidity sensor Light Indication Alert When the concentration of CO is 0 ~ 49 ppm, green area flashes, indicating that the CO concentration is at a low level. Green Note: The display change of the color indicator bar is based on the CO concentration data. When the concentration of CO is more than 100 ppm, red area flashes, indicating that the CO concentration is at a dangerous level with alarm sound. EN When the concentration of CO is 50 ~ 99 ppm, yellow area flashes, indicating that the CO concentration is at a warning level with alarm sound. 04 Operation Press function button Switch °C / Press °C If there is no keystroke operation within 5 minutes, the device automatically enters power-saving mode. Press function button to wake up it. Long press function button Power on Long Bi Press Power off EN 05 Customize Sound Alarm Value Double-click function button to enter setting mode. Set single digit Press function button to adjustment value. Long press function button to confirm and exit. Long press function button to confirm and adjust number of digits. Press function button to adjustment value. Set ten, hundred figures During the setting process, there is no keystroke operation within 15 seconds, and the device automatically confirms the current setting operation and exits. For your safety, the range that can be set is: 25-125(Please refer to page 08 for the settings of the two modes) EN 06 When the device sounds an audible alarm, you can press the function button to pause it for 15 seconds. After 15 seconds, if the ambient carbon monoxide concentration still exceeds the standard, the buzzer will sound again until the carbon monoxide level is lower than the alarm value. BiBiBi...... When you use this device in outdoor scenes (such as camping, car, etc.), for safety reasons, it is recommended that you set the alarm value between 25 and 75 ppm. Warning When the device sounds an audible alarm, please open the window for ventilation as soon as possible, find the source at the same time, and cut it off. EN 07 Outdoor sound alarm mode and indoor sound alarm mode Outdoor sound alarm mode Indoor sound alarm mode Custom sound alarm value is set between 25 and 75 ppm. Custom sound alarm value is set between 75 and 125 ppm. This mode is suitable for outdoor scenes (camping, car, etc.) This mode is suitable for indoor scenes (kitchen, bedroom, etc.) The carbon monoxide concentration exceeds the custom alarm value you set, and the sound alarm emits a low-frequency alarm sound of "beep--,beep--,beep--". The carbon monoxide concentration exceeds the custom alarm value you set, and the sound alarm emits a low-frequency alarm sound of "beep--,beep--,beep--". The concentration of carbon monoxide continues to rise, and when it exceeds 100 ppm, the audible alarm emits a high-frequency alarm sound of "beep, beep, beep..." The concentration of carbon monoxide continues to rise, and when it exceeds 150 ppm, the audible alarm emits a high-frequency alarm sound of "beep, beep, beep..." EN 08 Note Do not expose this product to water and dust, nor place it in a high temperature environment exceeding 60°C, and keep it away from fire. The device is a precision measuring instrument, and it is not allowed to disassemble it without authorization. The charging cable and charging plug must support the relevant fast charging protocol at the same time in order to realize fast charging. When charging, due to the heating of the charging circuit and the battery, the temperature and humidity value may be 3°C ~ 5°C higher than the normal value. To obtain an accurate temperature and humidity measurement value, please read it after the device cools down to room temperature. If you want to stay out of use for a long time, please charge the device first, then turn it off and put it away. Endorsed by authoritative certifications from both China and the United States: 1.CNAS: China National Accreditation Service for Conformity Assessment LABORATORY ACCREDITATION CERTIFICATE (Registration No: CNAS L16927) 2.UL 217:January 2,2020 Standard for Safety Smoke Alarms; NO: HPT-230705L0112S 3.UL 2034: March 31, 2017 UL Standard for Safety Single and Multiple Station Carbon Monoxide Alarms; NO: HPT-230705L0109S FR Made in China EN 09Adobe PDF library 16.07 Adobe Illustrator(R) 24.0