TempStar Ventless 07610-002-66-59B [03-09-21]
Spec Sheet
Jackson - TEMPSTAR VER - High Temp Ventless Door Type Dishwasher
Not Your Device? Search For Manuals or Datasheets below:
File Info : application/pdf, 4 Pages, 740.45KB
Document DEVICE REPORTTEMPSTAR-VERwith Ventless and TempStar® EnergyRecovery TempStar® withVentlessand Energy Recovery Models TempStar® VER TempStar® HH-E VER Project Item Quantity CSI Section 11400 Approval Date Standard Features Mandatory Specs · Ventless: Does not require a hood Specify voltage ______________ · Energy Recovery Specify booster size __________ · Internal condensing system minimizes water vapor · Sani-SureTM nal rinse system ensures proper rinse water temperature Options 460V Electrical Single Phase · Multi-cycle timer (Extra Heavy, Heavy, Medium, Normal) · Specially designed stainless steel nozzles provide superior cleaning action · Automatic tank ll/auto-start · Door switch Drain Water Tempering Kit Scaltrol Water Hammer Arrestor Flanged Feet False Panel (for corner installations) Security Package · Door interlock · Pressure regulator is provided for installation by others Accessories · Delime/manual wash switch 36-Compartment Rack · Hi-limit thermostat and low water protection · Uses standard 20" X 20" (508 mm X 508 mm) racks · Detergent/rinse additive signal connection fuse box 4-1/8" tall (105 mm) 5-5/8" tall (143 mm) 7" tall (178 mm) Combination Rack Peg Rack · Self-draining stainless steel pump · Built-in 70° F (38.9° C) rise booster heater · Field convertible from straight through to corner and vice versa (kit required) Specifications · TempStar VER uses 0.89 gallons (3.37 liters) of water per rack; TempStar HH-E VER uses 0.72 gallons (2.73 liters) of water per rack · TempStar VER (normal) cycle time - 87 seconds; TempStar HH-E VER (normal) cycle time - 90 seconds · TempStar VER - 41 (39)* racks per hour (normal cycle); TempStar HH-E VER - 40 (37)* racks per hour (normal cycle) · Single point connections for all utilities · Cold water connection only · Durable stainless steel construction · TempStar VER - 17.25" (438 mm) vertical chamber clearance · TempStar HH-E - 20.75" wide x 27" high (527 mm x 686 mm) opening accommodates 18"x 26" (457 mm x 660 mm) sheet pans and 60-quart mixing bowls · TempStar VER is eld phase convertible (kit required) · Both models require some assembly · 1-year parts and labor warranty *Racks per hour calculated with NSF suggested load time of ve (5) seconds for door-type (straight thru) www.jacksonwws.com with Ventless and TempStar® EnergyRecovery TempStar VER B 514 (134 mm) 30 7 8 (785 mm) 4 (102 mm) MINIMUM LEGEND A - Drain (1 1/2" NPT) B - Water Inlet (3/4" NPT) C - Electrical Connection can be increased 1 1/8" using the machine's adjustable feet. 2514 (641 mm) 32 (813 mm) B B 17 (432 mm) 3 (79 mm) CAC CCA 2414 (616 mm) 60 (1527 mm) 82 (2083 mm) 77 (1956 mm) 17 1 4 (438 mm) CLEARANCE 14 (356 mm) 5734 (1468 mm) AA 1512 (394 mm) 34 (864 mm) TABLE HEIGHT TABLE DIMENSIONS CONNECTION TO DISHMACHINE AAA 434 (120 mm) 3/4" (1.9 cm) www.jacksonwws.com (522.10c1m/2) " 1 1/2" (3.81 cm) ROLL with Ventless and TempStar® EnergyRecovery B 514 (134 mm) 4 (102 m MINIMUM 2514 (641 mm) 2 8 5 8 (727 mm) 17 (432 mm) B C TempStar HH-E VER LEGEND A - Drain (1 1/2" NPT) B - Water Inlet (3/4" NPT) C - Electrical Connection can be increased 1 1/8" using the machine's adjustable feet. 35 5 8 (905 mm) 234 (79 mm) 93 (2362 88 (2235 mm) 73 (1856 mm) 2 7 (686 mm) CLEARANCE 1134 (298 mm) 1514 (387 mm) A 34 (861 mm) TABLE DIMENSIONS CONNECTION TO DISHMACHINE 3/4" (1.9 cm) (522.10c1m/2) " www.jacksonwws.com 1 1/2" (3.81 cm) ROLL with Ventless and TempStar® EnergyRecovery MACHINE DIMENSIONS MODEL NO. HEIGHT WIDTH WIDTH BETWEEN TABLES TempStar 82" 32" VER (2083 mm) (813 mm) 25-1/4" (641 mm) DEPTH 30-7/8" (785 mm) TempStar 93" 28-5/8" HH-E VER (2362 mm) (727 mm) 25-1/4" (641 mm) 35-5/8" (905 mm) DRAIN SHIPPING INFORMATION HEIGHT WEIGHT CLASS CUBE 14" 358 lbs (356 mm) (163 kg) 200 87.79 cu. ft. 11-3/4" 451 lbs (298 mm) (205 kg) 200 84.35 cu. ft. HEIGHT 86" (2185 mm) 82.625" (2099 mm) WIDTH 42" (1067 mm) 42" (1067 mm) DEPTH 42" (1067 mm) 42" (1067 mm) DIMENSION REQUIREMENTS Wall Clearance (minimum) Clearance above Heat Exchanger (minimum) Standard Table Height Inside Vertical Clearance - TempStar VER Inside Vertical Clearance - TempStar HH-E VER 0" (0 mm) 6" (152 mm) 34" (864 mm) 17-1/4" (438 mm) 27" (686 mm) OPERATING CAPACITY Normal Medium Heavy Extra Heavy Racks per Hour - TempStar VER 41 (39)* 24 (23)* 17 (16)* 11 (10)* Racks per Hour - TempStar HH-E VER 40 (37)* 23 (22)* 16 (16)* 10 (10)* OPERATING TEMPERATURES Wash (minimum) - TempStar VER Wash (minimum) - TempStar HH-E VER Rinse (minimum) 150 °F (66 °C) 155 °F (69 °C) 180 °F (82 °C) OPERATING CYCLE FOR TEMPSTAR VER Wash Rinse Normal 40 10 Medium 100 10 Heavy 160 10 Extra Heavy 280 10 Dwell Condensate Removal Total Cycle 7 30 87 7 30 147 7 30 207 7 30 327 OPERATING CYCLE FOR TEMPSTAR HH-E VER Wash Rinse Dwell Normal 40 10 10 Condensate Removal Total Cycle 30 90 Medium 103 10 10 30 153 Heavy 163 10 10 30 213 Extra Heavy 283 10 10 30 333 ELECTRICAL REQUIREMENTS Model Power Supply TempStar VER TempStar HH-E VER 208/60/3 230/60/3 460/60/3 208/60/1 230/60/1 208/60/3 230/60/3 460/60/3 208/60/1 230/60/1 TANK HEATER SPECIFICATIONS Total Load 45.6 A 49.8 A 24.2 A 75.2 A 82.7 A 51.8 A 56.0 A 25.7 A 81.4 A 88.9 A Electric Wash Tank Heater Electric Rinse Tank Heater - 70°F (38.9°C) Rise Minimum Circuit Ampacity 46.8 A 51.1 A 24.7 A 76.5 A 83.9 A 54.6 A 58.8 A 26.5 A 84.2 A 91.7 A Maximum Overcurrent Protection 50 A 60 A 30 A 80 A 90 A 70 A 70 A 30 A 100 A 100 A Volts KW 208V 4.1 230V 5.0 460V 5.0 208V 10.5 230V 12.9 460V 12.9 WASH PUMP MOTOR Wash Pump Motor - TempStar VER 1 hp Wash Pump Motor - TempStar HH-E VER 2 hp AMBIENT HEAT LOAD (as tested on standard height model) Latent Heat (BTU) Sensible Heat (BTU) 5300 4500 WATER REQUIREMENTS TempStar VER TempStar HH-E VER Inlet Temperature Gallons per Hour Gallons per Hour** Gallons per Rack Waterline Size MIP (minimum) Drainline Size IPS (minimum) Flow Pressure (PSI) Connection Operating Flow Pressure (PSI) Wash Tank Capacity 40 - 90 °F (4.4 - 32.2 °C) 36.49 gal (138.13 L) 28.80 gal (109.02 L) 34.71 gal (131.39 L) 26.64 gal (100.84 L) 0.89 gal (3.37 L) 0.72 gal (2.73 L) 3/4" 3/4" 1- 1/2" 1- 1/2" 40 40 10 10 8 gal (30 L) 8 gal (30 L) Booster Tank Capacity 3 gal (11 L) 3 gal (11 L) HOW TO SPECIFY: TempStar® VER HOW TO SPECIFY: TempStar® HH-E VER *Racks per hour calculated with NSF suggested load time of ve (5) seconds for door-type (straight thru) **Gallons per hour calculated with NSF suggested load time of ve (5) seconds for door-type (straight thru) Jackson WWS, Inc. Shipping Address: 6209 North U.S. Highway 25E, Gray, KY 40734 Mailing Address: P.O. Box 1060, Barbourville, KY 40906 Telephone: 888-800-5672 · Fax: 606-523-1799 Email: [email protected] 07610-002-66-59B [03/09/21] www.jacksonwws.com We reserve the right to change speci cations in this bulletin without incurring any obligation for equipment previously or subsequently sold.Adobe Illustrator 25.0 (Windows) Adobe PDF library 15.00