EN55022&24 report

leon chen Shenzhen Microtest Co.,Ltd.

RF Exposure Info

TIZE INTERNATIONAL CO.,LIMITED TZ-926 Remote Dog Training Collar 2AY3ETZ-926 2AY3ETZ926 tz 926

PDF Viewing Options

Not Your Device? Search For Manuals or Datasheets below:


File Info : application/pdf, 8 Pages, 269.26KB

Document DEVICE REPORTGetApplicationAttachment.html?id=6828273
- Page 1 of 8 -

Report No.: HB20230911004E-02

RF EXPOSURE Test Report

Product: Remote Dog Training Collar Trade Mark: Model Number: TZ-926
FCC ID: 2AY3ETZ-926
Prepared for TIZE INTERNATIONAL CO., LIMITED 3/F, Building 1, TianKou Industrial Area, Huang Tian, Xixiang, BaoAn District, ShenZhen, GuangDong Province, China
Prepared by Shenzhen HongBiao Certification& Testing Co., Ltd Room 102, 201, Building 2, Yuanwanggu RFID Industrial Park, Tongguan Road, Tianliao Community, Yutang Street, Guangming District, Shenzhen,
China Tel.: +86-755-2998 9321 Fax.: +86-755-2998 5110
Website: http://www.sz-hongbiao.com

Add:Room 102, 201, Building 2, Yuanwanggu RFID Industrial Park, Tongguan Road, Tianliao Community, Yutang Street, Guangming District, Shenzhen,China

Tel: (86-755) 29989321

Fax: (86-755) 29985110

Web:www.sz-hongbiao.com

- Page 2 of 8 -

Report No.: HB20220505001E-01

Table of Contents
1 GENERAL DESCRIPTION ..................................................................................................................................... 5
1.1 DESCRIPTION OF EUT................................................................................................................................................. 5 1.2 TEST MODE.............................................................................................................................................................. 5 1.3 TEST SETUP .............................................................................................................................................................. 5 1.4 ANCILLARY EQUIPMENT .............................................................................................................................................. 5
2 TEST FACILITIES AND ACCREDITATIONS .............................................................................................................. 6
2.1 TEST LABORATORY ..................................................................................................................................................... 6 2.2 ENVIRONMENTAL CONDITIONS ..................................................................................................................................... 6 2.3 MEASUREMENT UNCERTAINTY ..................................................................................................................................... 6 2.4 TEST SOFTWARE ........................................................................................................................................................ 6
3 LIST OF TEST EQUIPMENT .................................................................................................................................. 6
4 RF EXPOSURE .................................................................................................................................................... 8
4.1 STANDALONE SAR TEST EXCLUSION CONSIDERATIONS........................................................................................................ 8 4.1.1 Limit.................................................................................................................................................................. 8 4.1.2 Test Procedures................................................................................................................................................. 8 4.1.3 Test Result ................................................................................................................................................... 8

Add:Room 102, 201, Building 2, Yuanwanggu RFID Industrial Park, Tongguan Road, Tianliao Community, Yutang Street, Guangming District, Shenzhen,China

Tel: (86-755) 29989321

Fax: (86-755) 29985110

Web:www.sz-hongbiao.com

- Page 3 of 8 -

Report No.: HB20220505001E-01

TEST RESULT CERTIFICATION

Applicant's Name................. : TIZE INTERNATIONAL CO., LIMITED

Address ................................. :

3/F, Building 1, TianKou Industrial Area, Huang Tian, Xixiang, BaoAn District, ShenZhen, GuangDong Province, China

Manufacturer's Name .......... : ShenZhen TIZE Technology Co., Ltd

205. Building 18, Jiatiangang Industrial Zone, Huangtian Address ................................. : Community, Hangcheng Street, Bao'an District, Shenzhen,
China

Product description Product name ........................ : Remote Dog Training Collar

Model Number ....................... : TZ-926 Standards ............................. : FCC CFR 47 PART 1, 1.1310 Test procedure..................... : KDB 447498 D04 This device described above has been tested by Shenzhen HongBiao Certification& Testing Co,.Ltd and the test results show that the equipment under test (EUT) is in compliance with the EMC requirements. And it is applicable only to the tested sample identified in the report.

Date of Test ........................................... :

Date (s) of performance of tests ............. : September 04, 2023~September 19, 2023

Test Result.............................................. : Pass

Testing Engineer

:

(Zoe Su)

Technical Manager :

(Gary Lu)

Authorized Signatory :

(Leo Su)

Add:Room 102, 201, Building 2, Yuanwanggu RFID Industrial Park, Tongguan Road, Tianliao Community, Yutang Street, Guangming District, Shenzhen,China

Tel: (86-755) 29989321

Fax: (86-755) 29985110

Web:www.sz-hongbiao.com

Revised No. 01

- Page 4 of 8 -

Report No.: HB20220505001E-01

Revision History
Date of Issue September 20, 2023

Description Original

Add:Room 102, 201, Building 2, Yuanwanggu RFID Industrial Park, Tongguan Road, Tianliao Community, Yutang Street, Guangming District, Shenzhen,China

Tel: (86-755) 29989321

Fax: (86-755) 29985110

Web:www.sz-hongbiao.com

- Page 5 of 8 -

Report No.: HB20220505001E-01

1 General Description
1.1 Description of EUT

Product name: Model name: Series Model:
Different of series model:
Operation frequency: Modulation type: Antenna type: Antenna gain: Hardware version: Software version: Battery: Power supply: Adapter information: 1.2 Test Mode

Remote Dog Training Collar
TZ-926 TZ-920, TZ-921, TZ-922, TZ-923, TZ-925, TZ-927, TZ-928, TZ-929, TZ-930, TZ-931, TZ-932, TZ-933, TZ-935 The color of appearance and model name of series models listed are different from the main model, but the circuit and the electronic construction are the same, declared by the manufacturer. 433.92MHz
FSK
Integral Antenna
0dBi
V1.0
V1.0
DC 3.7V/500mAh DC 3.7V by battery, USB 5V charging
Input: AC 100-240V, 50/60Hz, Output: DC 5V/2A

Pretest Test Mode

Description of Mode

1

TX

2

/

3

/

1.3 Test Setup

See photographs of the test setup in the report for the actual setup and connections between EUT and support equipment.

1.4 Ancillary Equipment

Equipment

Model

S/N

Manufacturer

/

/

/

/

Add:Room 102, 201, Building 2, Yuanwanggu RFID Industrial Park, Tongguan Road, Tianliao Community, Yutang Street, Guangming District, Shenzhen,China

Tel: (86-755) 29989321

Fax: (86-755) 29985110

Web:www.sz-hongbiao.com

- Page 6 of 8 -

Report No.: HB20220505001E-01

2 Test Facilities and Accreditations

2.1 Test Laboratory

Test Site
Test Site Location
Telephone: Fax: FCC Registration No.: A2LA Certificate No.:

Shenzhen HongBiao Certification& Testing Co., Ltd Room 102, 201, Building 2, Yuanwanggu RFID Industrial Park, Tongguan Road, Tianliao Community, Yutang Street, Guangming District, Shenzhen, China (86-755) 2998 9321
(86-755) 2998 5110
CN1341
6765.01

2.2 Environmental Conditions

During the measurement the environmental conditions were within the listed ranges:

Temperature:

15ºC~35ºC

Relative Humidity:

20%~75%

Air Pressure:

98kPa~101kPa

2.3 Measurement Uncertainty
The reported uncertainty of measurement y ± U, where expended uncertainty U is based on a standard uncertainty multiplied by a coverage factor of k=2, providing a level of confidence of approximately 95 %.

Measurement Frequency Range RF frequency RF power, conducted Conducted emission(150kHz~30MHz) Radiated emission(30MHz~1GHz) Radiated emission (above 1GHz) Temperature Humidity

U(dB) 2x 10-5 ± 0.57 dB ± 2.5 dB ± 4.2 dB ± 4.7 dB ±1 degree ± 5 %

Note

2.4 Test Software Software name
EMI Measurement

Manufacturer Farad

Model EZ-EMC

Version V1.1.4.2

Add:Room 102, 201, Building 2, Yuanwanggu RFID Industrial Park, Tongguan Road, Tianliao Community, Yutang Street, Guangming District, Shenzhen,China

Tel: (86-755) 29989321

Fax: (86-755) 29985110

Web:www.sz-hongbiao.com

- Page 7 of 8 -

Report No.: HB20220505001E-01

3 List of Test Equipment

Radiation emission

Item

Equipment No.

Equipment name

Manufacture r

Model

Serial No.

Calibration date

Due date

1

HB-E001

Horn Antenna

Schwarzbec k

BBHA 9120D

02592

2022-04-02 2024-04-01

Biconical

2

HB-E002

log-periodic Schwarzbec

composite

k

VULB 9168

01340

2022-04-06 2024-04-05

antenna

3

HB-E003

SHF-EHF Schwarzbec BBHA

Horn

k

91270

01193

2022-04-02 2024-04-01

4

HB-E004 Preamplifier

Noyetec

LAN-09 NYCM1420

10

101

2023-05-11

2024-05-10

5

HB-E005 Preamplifier

Noyetec

LAN-011 NYCM1420

8

102

2023-05-12

2024-05-11

6

HB-E006 Preamplifier

Noyetec

LAN-18 NYCM1420

40

103

2023-06-11

2024-06-10

7

HB-E007

EMI TEST RECEIVER

R&S

ESR7

102520 2023-05-12 2024-05-11

POSITINAL

8

HB-E009 COTROLLE Noyetec

N/A

N/A

/

/

R

9

HB-E013 RF switch

Noyetec

NY-RF4

NY0CM142 0204

/

/

10

HB-E066

Illuminance Tester

TASI

TA8121

N/A

2023-05-11 2024-05-10

11

HB-E075

Active loop Schwarzbec

antenna

k

FMZB 1519B

1519B-245 2022-07-24 2024-07-23

Note: the calibration interval of the above test instruments is 12 months and the calibrations are traceable to international system unit (SI).

Add:Room 102, 201, Building 2, Yuanwanggu RFID Industrial Park, Tongguan Road, Tianliao Community, Yutang Street, Guangming District, Shenzhen,China

Tel: (86-755) 29989321

Fax: (86-755) 29985110

Web:www.sz-hongbiao.com

- Page 8 of 8 -

Report No.: HB20220505001E-01

4 RF Exposure Evaluation
4.1 Standalone SAR test exclusion considerations
4.1.1 Limit
The available maximum time-averaged power is no more than 1 mW.
4.1.2 Test Procedures
According to KDB 447498 D04 RF Exposure Procedures and Equipment Authorization Policies for Mobile and Portable Devices part 2.1.2, a single RF source is exempt RF device (from the requirement to show data demonstrating compliance to RF exposure limits, as previously mentioned) if the available maximum time-averaged power is no more than 1mW, regardless of separation distance. This exemption applies to all operating configurations and exposure conditions, for the frequency range 100 kHz to 100 GHz, regardless of fixed, mobile, or portable device exposure conditions. This is a standalone exemption, and it cannot be applied in conjunction with any other test exemption.

The result is rounded to one decimal place for comparison

Here, The device has been evaluated to meet general RF exposure requirement. The device can be used in portable exposure condition without restriction.

4.1.3

Test Result

Frequency (MHz) 433.92

Power (dBuV/m)
79.13

Power (dBm) -16.07

Notes: 79.13dBuV/m-95.2=-16.07dBm

0.02mW1Mw, so a SAR test is not required.

Power (mW) 0.02

Limit (mW)
1

****** END OF REPORT ******

Add:Room 102, 201, Building 2, Yuanwanggu RFID Industrial Park, Tongguan Road, Tianliao Community, Yutang Street, Guangming District, Shenzhen,China

Tel: (86-755) 29989321

Fax: (86-755) 29985110

Web:www.sz-hongbiao.com



Related FCC IDs:

Search Any Device: