Datasheet Xi 36W/m 0.7-0.85A 42V DS S TD 230V
飞利浦LED照明灯具产品使用说明资料下载 - 飞利浦专业照明
Technical downloads | Philips lighting
Not Your Device? Search For Manuals or Datasheets below:
File Info : application/pdf, 8 Pages, 2.46MB
Document DEVICE REPORTXi 36W m 0.7-0.85A 42V DS S TD 230V 929003425180Xitanium LED driver Datasheet Xitanium Mini Dali DS Xi 36W/m 0.7-0.85A 42V DS S TD 230V 9290 034 25180 Enabling future-proof LED technology Philips Xitanium LED Point drivers are designed to operate with LED COB solutions used both in built-in and independent applications such as down light, spot light and track light. Xitanium drivers have common features such as low ripple output current, adjustable output current by dip switch and 50,000 hours lifetime. They are specifically designed to ensure great EMI performance, high robustness and safe usage. Benefits · Dali 2.0 enables wired digital controls · Provides options for different luminaire designs · Great EMI performance for easy design-in · Enables minimization of luminaire · Selectable output current enables flexibility · Peace of mind with proven reliability Features · Dali 2.0 with 1-100% dimming · Class I and II application · Low Ripple less than 4% · Small size with Mini Shape · 4 output currents by Dip switch · 50,000 hours lifetime Application · Down lighting · Spot lighting · Track lighting February 2023 Electrical input data Specification item Rated input voltage range Rated input voltage Rated input frequency range Rated input current Rated input power Nominal Power factor Total harmonic distortion Efficiency Input voltage AC range Input frequency AC range Standby Power (no load) Isolation input to output Electrical output data Specification item Regulation method Output voltage Output voltage max. Output current Output current tolerance ± Output current ripple LF Output current ripple HF Output PstLM Output SVM Output power Value 220...240 230 50...60 0.18 43 0.96 20 88 198...264 47.5...63 0.50 SELV Unit Vac Vac Hz A W % % Vac Hz W Value Constant Current 30...42 60 0.7 / 0.75 / 0.8 / 0.85 5 4 15 0.1 0.1 21...35.7 Unit Vdc V A % % % W Electrical data controls input Specification item Control method Dimming range Isolation controls input to output Value Unit Corridor Mode, DALI, Touch & Dim (TD) 1...100 % Reinforced Condition Performance range Performance range @ full output power @ rated input voltage @ full output power @ rated input voltage @ rated output power @ rated input voltage @ rated output power @ rated input voltage @ full output power @ rated input voltage @ max. Uout Operational range Operational range Condition Maximum output voltage (rms) @full load Ripple = peak / average, < 3kHz In entire operating window In entire operating window Condition See design-in guide at www.philips.com/oem for more controllability details. Default range acc. IEC61347-1 2 / 8 Xi 36W/m 0.7-0.85A 42V DS S TD 230V February 2023 Wiring and Connections Specification item Input wire cross-section Input wire strip length Output wire cross-section Output wire strip length Control wire cross-section Control wire strip length Maximum cable length Value 0.5...1.5 / 20...16 8.5...9.5 0.5...1.5 / 20...16 8.5...9.5 0.5...1.5 / 20...16 8.5...9.5 0.6 Unit mm2 / AWG mm mm2 / AWG mm mm2 / AWG mm m Type Type 250, solid / stranded wire Type 250, solid / stranded wire Type 250, solid / stranded wire Total length of wiring including LED module, one way Isolation Insulation per IEC61347-1 Input Output DALI Input SELV Basic Output SELV Reinforced DALI Basic Reinforced - 3 / 8 Xi 36W/m 0.7-0.85A 42V DS S TD 230V February 2023 Dimensions and weight Specification item Length (A1) Mounting hole distance (A2) Width (B1) Width (B2) Height (C1) Mounting hole diameter (D1) Weight Housing color Value 97.2 88.3 43.2 34.3 30 4.2 110 white Unit Tolerance (mm) mm mm mm mm mm mm gram Logistical data Specification item Product name Logistic code 12NC Pieces per box Value Xi 36W/m 0.7-0.85A 42V DS S TD 230V 9290 034 25180 40 Operational temperatures and humidity Specification item Value Unit Ambient temperature -20...+50 ºC Tcase-max 80 ºC Tcase-life 80 ºC Maximum housing temperature 110 ºC Relative humidity 10...90 % Condition Higher ambient temperature allowed as long as Tcase-max is not exceeded Maximum temperature measured at Tcase-point Measured at Tcase-point In case of a failure, inherent by design Non-condensing 4 / 8 Xi 36W/m 0.7-0.85A 42V DS S TD 230V February 2023 Lifetime Specification item Driver lifetime Driver lifetime Value 50,000 100,000 Unit hours hours Condition Measured temperature at Tcase-point is Tcase-life. Maximum failures = 10% Measured temperature at Tcase-point is Tcase-life -10 degrees. Maximum failures = 10% Storage temperature and humidity Specification item Ambient temperature Relative humidity Value -25...+85 5...95 Programmable features Specification item Set Adjustable Output Current (AOC) Adjustable Light Output (ALO) Constant Light Output (CLO) Touch & Dim (TD) Corridor Mode Min Dim Level OEM Write Protection (OWP) Available DipSwitch Yes Yes Yes Yes Yes Yes Features Specification item Open load protection Short circuit protection Over power protection Suitable for fixtures with protection class Value Yes Yes Yes I and II Unit Condition ºC % Non-condensing Default setting 700 mA ON ON OFF Condition Factory default setting: ON Default: T1=55s, T2=12s, T3=30min Condition Automatic recovering Automatic recovering Automatic recovering per IEC60598 5 / 8 Xi 36W/m 0.7-0.85A 42V DS S TD 230V February 2023 Inrush current Specification item Inrush current Inrush peak width Drivers / MCB 16A type B Value 16.5 177 36 Unit A µs pcs Condition Input voltage 230V Input voltage 230 V, measured at 50% height Indicative value at 230V Please refer to the driver design in guide if you use other MCB-types. Driver touch current / protective conductor current / earth leakage current Specification item Typical Touch Current (ins. Class II) Value 0.7 Unit mA peak Condition Acc. IEC61347-1. LED module contribution not included Surge immunity Specification item Mains surge immunity (diff. mode) Mains surge immunity (comm. mode) Control surge immunity (diff. mode) Control surge immunity (comm. mode) Value 1 2 1 2 Unit kV kV kV kV Condition Acc. IEC61000-4-5. 2 Ohm, 1.2/50us, 8/20us Acc. IEC61000-4-5. 12 Ohm, 1.2/50us, 8/20us Acc. IEC61000-4-5. 2 Ohm, 1.2/50us, 8/20us Acc. IEC61000-4-5. 12 Ohm, 1.2/50us, 8/20us Application Info Specification item Approval marks and Certifications Ingress Protection classification (IP) Application Mounting Type Value CB / CCC / CE / DALI 2 / EAC / ENEC / RCM / SELV / TISI / UKCA 20 Indoor Point Built-in 6 / 8 Xi 36W/m 0.7-0.85A 42V DS S TD 230V February 2023 Graphs Operating window Power factor versus output power Efficiency versus output power 7 / 8 Xi 36W/m 0.7-0.85A 42V DS S TD 230V February 2023 THD versus output power Notes Electrical Specifications: All the specifications are typical and at 25°C Ta unless specified otherwise. ©2022 Signify Holding, IBRS 10461, 5600 VB, NL. All rights reserved. UK importer address: Signify Commercial UK Limited, 3, Guildford Business Park, GU2 8XG. The information provided herein is subject to change without notice. Signify does not give any representation or warranty as to the accuracy or completeness of the information included herein and shall not be liable for any action in reliance thereon. The information presented in this document is not intended as any commercial offer and does not form part of any quotation or contract, unless otherwise agreed by Signify. Philips and the Philips Shield Emblem are registered trademarks of Koninklijke Philips N.V. All other trademarks are owned by Signify Holding or their respective owners. Date of release: March 1, 2023 v9 www.philips.com/oemtFPDF 1.24