zmp

RF Exposure

Shenzhen Loyal Electronics Co., Ltd. D1367C10 WIRELESS MOUSE 2AAVD-D1367C10 2AAVDD1367C10 d1367c10

PDF Viewing Options

Not Your Device? Search For Manuals or Datasheets below:


File Info : application/pdf, 1 Pages, 145.40KB

Document DEVICE REPORTGetApplicationAttachment.html?id=7385644
RF Exposure Evaluation

FCC ID: 2AAVD-D1367C10

According to KDB 447498 D01 General RF Exposure Guidance v06 and part 2.1093Unless specifically required by the published RF exposure KDB procedures, standalone 1-g head or body and 10-g extremity SAR evaluation for general population exposure conditions, by measurement or numerical simulation, is not required when the corresponding SAR Test Exclusion Threshold condition(s), listed below, is (are) satisfied.
For 100 MHz to 6 GHz and test separation distances  50 mm, the 1-g and 10-g SAR test exclusion thresholds are determined by the following: [(max. power of channel, including tune-up tolerance, mW) / (min. test separation distance, mm)] · [f(GHz)]  3.0 for 1-g SAR, and  7.5 for 10-g extremity SAR, where
f(GHz) is the RF channel transmit frequency in GHz Power and distance are rounded to the nearest mW and mm before calculation The result is rounded to one decimal place for comparison
Here, The device has been evaluated to meet general RF exposure requirement. The device can be used in portable exposure condition without restriction.

For BLE
Max Conducted Power(dBm)
-6.61

Tune-up Power(dBm)
-6(±1)

Max Tune-up Power(dBm)
-5

Max Power(mW)
0.32

Frequency(MHz) 2480

Min. distance(mm)
5

Calc. thresholds
0.100787

limit 3.0

So a SAR test is not required

2.4G Max
Conducted Power(dBm)
-1

Tune-up Power(dBm)
-1(±1)

Max Tune-up Power(dBm)
0

Max Power(mW)
1

Frequency(MHz) 2480

Min. distance(mm)
5

Calc. thresholds
0.270715

limit 3.0

Notes: 94.2dBuV/m-95.2=-1dBm



Related FCC IDs:

Search Any Device: