BKDB1, BKDEG1, BKSA1, BKSH1 Inst Manual (99045655-002F)

BeaulieuD

Installation Guide

BKDEG130WW in White by Broan in Lakewood, NJ - Broan Sahale 30-Inch Convertible Under-Cabinet Range Hood, ENERGY STAR , 375 Max Blower CFM, White

BKDEG130SS in Stainless Steel by Broan in Watertown, NY - Broan Sahale 30-Inch Convertible Under-Cabinet Range Hood, ENERGY STAR , 375 Max Blower CFM, Stainless Steel

BKSH130WW in White by Broan in Schenectady, NY - Broan 30-Inch 300 Max Blower CFM 5.0 Sones White Range Hood

PDF Viewing Options

Not Your Device? Search For Manuals or Datasheets below:


File Info : application/pdf, 30 Pages, 7.76MB

Document DEVICE REPORTmeoonviykljx
WWW.BROAN.COM

WWW.BROAN.CA

RANGE HOOD
Series: BKDB1, BKDEG1, BKSA1 and BKSH1
INSTALLATION, USE AND CARE MANUAL
English - See page 2
HOTTE DE CUISINIÈRE
Séries : BKDB1, BKDEG1, BKSA1 et BKSH1
MANUEL D'INSTALLATION, D'UTILISATION ET D'ENTRETIEN
Français - Voir en page 31
CAMPANA DE COCINA
Series: BKDB1, BKDEG1, BKSA1 y BKSH1
MANUAL DE INSTALACIÓN, USO Y CUIDADO
Español - Vease la pagína 60

Serial number:

99045655-002F

Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-4
Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-6
Cleaning and Maintenance . . . . . . . . . . . . . . . . . .7
Motor Grease Filter(s) Non-Ducted Recirculation Filter(s) Fan Blade Stainless Steel Cleaning Painted Finish Cleaning
Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-22
Recommended Tools and Accessories for Installation . . . . . . . . . . . . 8 Install Ductwork (Ducted Installations Only) . . . 8-9 Contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-10 Prepare the Hood . . . . . . . . . . . . . . . . . . . . . . . 11-13 Prepare the Hood Location . . . . . . . . . . . . . . . . 14
EZ1 One-Person Installation . . . . . . . . . . . . . 14-16 Install the Hood (EZ1 Bracket). . . . . . . . . . . . 17-18 Standard Installation . . . . . . . . . . . . . . . . . . . 19 Install the Hood (Standard Installation) . . . . . 20 Connect the Wiring . . . . . . . . . . . . . . . . . . . . . . 21 Light Bulbs (BKSA1 and BKSH1 Series only) . 22 Install the Filter(s) . . . . . . . . . . . . . . . . . . . . . . . 22
Wiring Diagrams . . . . . . . . . . . . . . . . . . . . . . 23-25
Service Parts . . . . . . . . . . . . . . . . . . . . . . . . . 26-29
Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .30
2

INSTALLATION MANUAL
TABLE OF CONTENTS

READ AND SAVE THESE INSTRUCTIONS
! Intended for domestic cooking only !
INSTALLER: LEAVE THIS MANUAL WITH HOMEOWNER.
In U.S.A., register your range hood online at www.broan.com In Canada, register your range hood online at www.broan.ca
! WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:
· Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer at the address or telephone number listed in the warranty.
· Before servicing or cleaning unit, switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.
· Installation work and electrical wiring must be done by a qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction.
· Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning equipment to prevent backdrafting. Follow the heating equipment manufacturer's guidelines and safety standards such as those published by the National Fire Protection Association (NFPA) and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE) and the local code authorities.
· When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.
· Ducted fans must always be vented to the outdoors.
· Do not use this unit with any additional solid-state speed control device.
· To reduce the risk of fire, use only metal ductwork.
· This unit must be grounded.
· As an alternative, this product may be installed with the UL-approved cord kit designated for the product, following instructions packed with the cord kit.
· When applicable local regulations comprise more restrictive installation and/or certification requirements, the aforementioned requirements prevail on those of this document and the installer agrees to conform to these at his own expense.

INSTALLATION MANUAL
SAFETY

3

INSTALLATION MANUAL
SAFETY

4

! WARNING
TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE:
a) Never leave surface units unattended at high settings. Boilovers cause smoking and greasy spillovers that may ignite. Heat oils slowly on low or medium settings.
b) Always turn hood ON when cooking at high heat or when flambeing food (i.e.: Crêpes Suzette, Cherries Jubilee, Peppercorn Beef Flambé).
c) Clean ventilating fan frequently. Grease should not be allowed to accumulate on fan, filters or in exhaust ducts.
d) Use proper pan size. Always use cookware appropriate for the size of the surface element.
TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP GREASE FIRE, OBSERVE THE FOLLOWING*:
1. SMOTHER FLAMES with a close-fitting lid, cookie sheet or metal tray, then turn off the burner. BE CAREFUL TO PREVENT BURNS. IF THE FLAMES DO NOT GO OUT IMMEDIATELY, EVACUATE AND CALL THE FIRE DEPARTMENT.
2. NEVER PICK UP A FLAMING PAN -- You may be burned. 3. DO NOT USE WATER, including wet dishcloths or towels -- This could
cause a violent steam explosion. 4. Use an extinguisher ONLY if:
A. You own a Class ABC extinguisher and you know how to operate it. B. The fire is small and contained in the area where it started. C. The fire department has been called. D. You can fight the fire with your back to an exit. * Based on "Kitchen Fire Safety Tips" published by NFPA.
! CAUTION
· For indoor use only. · For general ventilating use only. Do not use to exhaust hazardous or explosive materials
and vapors. · To avoid motor bearing damage and noisy and/or unbalanced fan blade, keep drywall
spray, construction dust, etc. off range hood. · Your hood motor has a thermal overload which will automatically shut off the motor if it
becomes overheated. The motor will restart when it cools down. If the motor continues to shut off and restart, have the hood serviced. · For best capture of cooking fumes, the bottom of the hood MUST NOT BE LESS than 18" and at a maximum of 24" above the cooking surface. · Always follows the cooking equipment manufacturer's requirements regarding the ventilation needs. · To reduce the risk of fire and to properly exhaust air, be sure to duct air outside -- Do not exhaust air into spaces within walls or ceiling or into attics, crawl space or garage. · When installing, servicing or cleaning the unit, it is recommended to wear safety glasses and gloves. · Please read specification label on product for further information and requirements.

Operation
Always turn your hood on before you begin cooking to establish an air flow in the kitchen. Let the blower run for a few minutes to clear the air after you turn off the range. This will help keep the whole kitchen cleaner and fresher. Operate the hood as follows:
BKDB1 AND BKDEG1 SERIES
BLOWER BUTTON When blower is OFF, press this button to turn ON the blower at the last saved speed. If there was no speed saved, the blower will be set on LOW speed. NOTE: When LOW speed is activated from OFF, the blower starts on MEDIUM speed for a very
short lapse of time, and then resume to LOW speed. To change the blower speed, press on this button again until the desired speed is reached (from LOW to MEDIUM to HIGH speed to OFF). Each time a blower speed is activated, a beep is heard and LED indicators light up to show the corresponding speed chosen (lower LED for LOW speed, lower and center LEDs for MEDIUM speed and all LEDs for HIGH speed). When blower is on (no matter the speed level), press and hold this button until the beep sound ends; this will turn off the blower and save this blower speed to memory.
LIGHT BUTTON When lights are OFF, press once on this button to turn ON the lights at the last saved setting. If there was no light setting saved, the lights will be set on LOW intensity. Press another time to set the lights on HIGH intensity. Pressing another time after the HIGH setting will turn OFF the lights. Each time the lights are turned ON, a beep is heard and LED indicators light up to show the corresponding intensity chosen (lower LED for LOW and both LEDs for HIGH). When lights are on (no matter the lighting level), press and hold this button until the beep sound ends; this will turn off the lights and save the chosen light intensity. The LED modules included with this hood are the latest in LED cooktop illumination technology specially designed to operate in the elevated temperatures of cooking - offering bright lighting and lasting up to 25 times as long as a standard bulb and greater reliability than typical replacement LED bulbs.
FILTER CLEANING REMINDER When it is time to clean the hood and filters (refer to Cleaning and Maintenance on page 7), the 3 blower button LED indicators will flash slowly for 30 seconds after turning the blower OFF. This will happen every time the blower is turned OFF until the filter cleaning reminder has been reset. Once the cleaning is done, reset the filter cleaning reminder indicators by pressing on blower button for 3 seconds during the 30 seconds the 3 blower button LED indicators flash slowly.
5

INSTALLATION MANUAL
OPERATION

BKSA1 SERIES

BLOWER SWITCH
I Turns blower on to LOW speed. · Turns blower OFF. II Turns blower on to HIGH speed.
BKSH1 SERIES

LIGHT SWITCH
I Turns light on in LOW intensity. · Turns light OFF. II Turns light on to HIGH intensity.

BLOWER SWITCH
 Turns blower OFF. I Turns blower on to LOW speed. II Turns blower on to HIGH speed.

LIGHT SWITCH
 Turns light OFF. I Turns light on to LOW intensity. II Turns light on to HIGH intensity.

INSTALLATION MANUAL
OPERATION

6

Cleaning and Maintenance
Proper maintenance of the Range Hood will assure proper performance of the unit.
MOTOR
The motor is permanently lubricated and never needs oiling. If the motor bearings make excessive or unusual noise, replace the motor with the exact service motor. The fan blade should also be replaced.
GREASE FILTER(S)
The grease filter(s) should be cleaned frequently. Use a warm dishwashing detergent solution. Grease filters are dishwasher safe. Clean all-metal filters in the dishwasher using a non-phosphate detergent. Discoloration of the filters may occur if using phosphate detergents, or as a result of local water conditions - but this will not affect filter performance. This discoloration is not covered by the warranty. To minimize or prevent discoloration, hand wash filters using a mild detergent.
NON-DUCTED RECIRCULATION FILTER(S)
The non-ducted recirculation filter(s) should be changed every 3 to 6 months. Replace more often if your cooking style generates extra grease, such as frying and wok cooking. Refer to installation instructions included with non-ducted recirculation filter(s).
FAN BLADE
The fan blade should be cleaned frequently. Use a clean cloth soaked with warm detergent solution.
STAINLESS STEEL CLEANING
Do:
· Regularly wash with clean cloth or rag soaked with warm water and mild soap or liquid dish detergent.
· Always clean in the direction of original polish lines. · Always rinse well with clear water (2 or 3 times) after cleaning. Wipe dry completely. · You may also use a specialized household stainless steel cleaner.
Don't:
· Use any steel or stainless steel wool or any other scrapers to remove stubborn dirt. · Use any harsh or abrasive cleansers. · Allow dirt to accumulate. · Let plaster dust or any other construction residues reach the hood. During construction/
renovation, cover the range hood to make sure no dust sticks to the stainless steel surface.
Avoid when choosing a detergent:
· Any cleaners that contain bleach will attack stainless steel. · Any products containing: chloride, fluoride, iodide, bromide will deteriorate surfaces
rapidly. · Any combustible products used for cleaning such as acetone, alcohol, ether, benzol, etc.,
are highly explosive and should never be used close to a range.
PAINTED FINISH CLEANING:
Clean with warm water and mild detergent only. If discoloration occurs, use a finish polish such as automotive polish. (DO NOT use rough abrasive cleaner or porcelain cleaner.)

INSTALLATION MANUAL
CLEANING AND MAINTENANCE

7

INSTALLATION MANUAL
INSTALLATION

8

For ADA compliance installation guidelines, please visit www.broan-nutone.com
Recommended Tools and Accessories for Installation
· Measuring tape · Phillips screwdriver no. 2 · Flat blade screwdriver (to open knockout holes) · Drill, 1/8" drill bit and 1½" hole saw (to mark holes for ducting and cut electrical access hole) · 7/64" drill bit (to drill holes for EZ1 brackets mounting screws, not for BKSA1 Series) · Wood shims (2) and wood screws (4) (required for standard installation to framed cabinet) · Saw (to cut holes for ducted application) · Sheet metal shears (ducted installation only, for duct adjustment) · Pliers (ducted installation only, for duct adjustment) · Metal foil duct tape (for ducted applications) · Scissors (to cut metal foil duct tape) · Pencil · Wire stripper · Strain relief, 1/2" diameter (to secure house wiring cable to the hood)
Install Ductwork (Ducted Installations Only)

ROOF CAP

3¼" X 10" OR 7" ROUND DUCT (FOR VERTICAL
DISCHARGE)

SOFFIT CABINET
HOOD
18" MIN - 24" MAX
ABOVE COOKING SURFACE

HOUSE WIRING (TOP OR BACK OF HOOD)
WALL CAP
3¼" X 10" DUCT (FOR HORIZONTAL DISCHARGE)

NOTE: Distances over 24" are at the installer and user discretion.

1 ] Determine whether hood will discharge vertically (3¼" x 10" or 7" round), or horizontally (3¼" x 10" only).
2 ] Decide where the ductwork will run between the hood and the outdoors.
3 ] The ducting from this fan to the outside of the building has a strong effect on the air flow, noise and energy use of the fan. Use the shortest, straightest duct routing possible for best performance, and avoid installing the fan with smaller ducts than recommended. Insulation around the ducts can reduce energy loss and inhibit mold growth. Fans installed with existing ducts may not achieve their rated airflow. Refer to the table on next page to help you plan the most efficient installation.
4 ] Install wall cap or roof cap (sold separately); ensure there is no leak in house insulation. Connect metal ductwork to cap and work back towards the hood location. Use 2" metal foil duct tape to seal the joints between ductwork sections.

Maximum Duct Lengths Recommended to Achieve 80% Exhaust Efficiency

3¼" X 10" HORIZONTAL MAXIMUM DUCT LENGTH
68 ft. 60 ft. 51 ft.

3¼" X 10" VERTICAL MAXIMUM DUCT LENGTH
51 ft. 42 ft. 33 ft.

7" ROUND MAXIMUM DUCT LENGTH
57 ft. 42 ft. 28 ft.

ROOF OR WALL CAP WITH DAMPER
1 1 1

ELBOW(S)* (90° AND/OR 45°)
0 1 2

* Standard elbows with 1" internal radius. NOTE: 6" round ducting is possible but may reduce exhaust efficiency.

Contents

Before proceeding to the installation, check the contents of the box. If items are missing or damaged, contact the manufacturer.

Make sure that the following items are included:

BKDB1 Series

BKDEG1 Series

* FIND INSIDE
OF HOOD

* FIND INSIDE
OF HOOD

(2) GREASE FILTERS

(1) 3¼" X 10" DAMPER ASSEMBLY*

(1) 7" ROUND DUCT CONNECTOR

EZ1 COMPONENTS

Use this template for marking; do not attempt to cut out the ducting hole through it. NOTE: These cutouts are clearance holes; they do not need to be the exact size of ducting. Utiliser ce gabarit pour marquer vos repères; ne pas tenter de découper le trou pour le conduit à travers le gabarit. NOTE : Les découpes incluent le jeu nécessaire à l'installation; elles ne doivent pas
être du format exact des conduits.
Use esta plantilla para crear marcados; no trate de cortar el agujero del conducto a través de la plantilla. NOTA: To be translated in Spanish.

C

Bend template along graduated scale when installing to framed cabinet.

Pour une installation sous une

armoire à fond en retrait, utiliser les

lignes pour mesurer l'épaisseur du

décalage causé par le mur de

l'armoire et plier le gabarit en conséquence.

8"

To be translated in Spanish.

CL

MARK WHERE INDICATED FOR THE APPROPRIATE SIZE DUCT OPENING

7" ROUND DUCTING

OR

RECTANGULAR DUCTING = 3¼" x 10"
= 3¼" x 14"

MARQUER LES REPÈRES AUX ENDROITS INDIQUÉS SELON LE FORMAT DE CONDUIT UTILISÉ

OU CONDUIT ROND DE 7 PO

CONDUIT RECTANGULAIRE = 3¼ po x 10 po = 3¼ po x 14 po

TITLE TO BE TRANSLATED IN SPANISH

O CONDUCTO REDONDO DE 7 PULG.

CONDUCTO RECTANGULAR = 3¼ pulg. x 10 pulg. = 3¼ pulg. x 14 pulg.

7½"

Electrical access hole center A = single blower hood B = double blower hood

VERTICAL
10½"
14½"
C

Centre du trou pour fil
EXHAUSTd'alimentation électrique A = hotte ventilateur simple B = hotte ventilateur double

4¼"

To be translated in Spanish Electrical access hole center A = single blower hood B = double blower hood
AB

C

Place this edge against back wall Appuyer ce bord au mur arrière Apoyar este borde contra la pared de atrás

(1) TEMPLATE FOR DUCTING (PRINTED BOTH SIDES)

(2) INSTALLATION BRACKETS**
FOR FRAMED CABINET

(2) INSTALLATION BRACKETS**
FOR FRAMELESS CABINET
** FIND EZ1 BRACKETS ATTACHED INSIDE OF HOOD (1) PARTS BAG*** CONTAINING:

(4) NO. 8-18 X 1/2" METAL SCREWS

(6) NO. 8 X 5/8" RD. HD.
WOOD SCREWS

(6) NO. 8 X 1/2" COUNTERSUNK WOOD SCREWS

*** FIND PARTS BAG BEHIND THE DAMPER ASSEMBLY INSIDE OF HOOD

(1) 3¼" X 10" (2) GREASE FILTERS DAMPER ASSEMBLY*

(1) 7" ROUND DUCT CONNECTOR

EZ1 COMPONENTS

Use this template for marking; do not attempt to cut out the ducting hole through it. NOTE: These cutouts are clearance holes; they do not need to be the exact size of ducting. Utiliser ce gabarit pour marquer vos repères; ne pas tenter de découper le trou pour le conduit à travers le gabarit. NOTE : Les découpes incluent le jeu nécessaire à l'installation; elles ne doivent pas
être du format exact des conduits.
Use esta plantilla para crear marcados; no trate de cortar el agujero del conducto a través de la plantilla. NOTA: To be translated in Spanish.

C

Bend template along graduated scale when installing to framed cabinet.

Pour une installation sous une

armoire à fond en retrait, utiliser les

lignes pour mesurer l'épaisseur du

décalage causé par le mur de

l'armoire et plier le gabarit en conséquence.

8"

To be translated in Spanish.

CL

MARK WHERE INDICATED FOR THE APPROPRIATE SIZE DUCT OPENING

7" ROUND DUCTING

OR

RECTANGULAR DUCTING = 3¼" x 10"
= 3¼" x 14"

MARQUER LES REPÈRES AUX ENDROITS INDIQUÉS SELON LE FORMAT DE CONDUIT UTILISÉ

OU CONDUIT ROND DE 7 PO

CONDUIT RECTANGULAIRE = 3¼ po x 10 po = 3¼ po x 14 po

TITLE TO BE TRANSLATED IN SPANISH

O CONDUCTO REDONDO DE 7 PULG.

CONDUCTO RECTANGULAR = 3¼ pulg. x 10 pulg. = 3¼ pulg. x 14 pulg.

7½"
V RTICAL EX
10½"
14½"
C

Electrical access hole center A = single blower hood B = double blower hood

A
4¼"

Centre du trou pour fil
S d'alimentation électrique A = hotte ventilateur simple B = hotte ventilateur double
To be translated in Spanish Electrical access hole center A = single blower hood B = double blower hood
AB
C

Place this edge against back wall Appuyer ce bord au mur arrière Apoyar este borde contra la pared de atrás

(1) TEMPLATE FOR DUCTING (PRINTED BOTH SIDES)

(2) INSTALLATION BRACKETS**
FOR FRAMED CABINET

(2) INSTALLATION BRACKETS**
FOR FRAMELESS CABINET
** FIND EZ1 BRACKETS ATTACHED INSIDE OF HOOD (1) PARTS BAG*** CONTAINING:
(4) NO. 8-18 X 1/2" METAL SCREWS

(6) NO. 8 X 5/8" RD. HD.
WOOD SCREWS

(6) NO. 8 X 1/2" COUNTERSUNK WOOD SCREWS

*** FIND PARTS BAG BEHIND THE DAMPER ASSEMBLY INSIDE OF HOOD

INSTALLATION MANUAL
INSTALLATION

9

BKSH1 Series

BKSA1 Series

(2) GREASE FILTERS

(2) SHIELDED HALOGEN BULBS (50W, GU10)
* FIND INSIDE OF HOOD

(1) 7" ROUND DUCT CONNECTOR

(1) 3¼" X 10" DAMPER ASSEMBLY*

EZ1 COMPONENTS

Use this template for marking; do not attempt to cut out the ducting hole through it. NOTE: These cutouts are clearance holes; they do not need to be the exact size of ducting. Utiliser ce gabarit pour marquer vos repères; ne pas tenter de découper le trou pour le conduit à travers le gabarit. NOTE : Les découpes incluent le jeu nécessaire à l'installation; elles ne doivent pas
être du format exact des conduits.
Use esta plantilla para crear marcados; no trate de cortar el agujero del conducto a través de la plantilla. NOTA: To be translated in Spanish.

C

Bend template along graduated scale when installing to framed cabinet.

Pour une installation sous une

armoire à fond en retrait, utiliser les

lignes pour mesurer l'épaisseur du

décalage causé par le mur de

l'armoire et plier le gabarit en conséquence.

8"

To be translated in Spanish.

CL

MARK WHERE INDICATED FOR THE APPROPRIATE SIZE DUCT OPENING

7" ROUND DUCTING

OR

RECTANGULAR DUCTING = 3¼" x 10"
= 3¼" x 14"

MARQUER LES REPÈRES AUX ENDROITS INDIQUÉS SELON LE FORMAT DE CONDUIT UTILISÉ

OU CONDUIT ROND DE 7 PO

CONDUIT RECTANGULAIRE = 3¼ po x 10 po = 3¼ po x 14 po

TITLE TO BE TRANSLATED IN SPANISH

O CONDUCTO REDONDO DE 7 PULG.

CONDUCTO RECTANGULAR = 3¼ pulg. x 10 pulg. = 3¼ pulg. x 14 pulg.

7½"

Electrical access hole center A = single blower hood B = double blower hood

VERTICAL
10½"
14½"
C

EXHAUSTCentre du trou pour fil d'alimentation électrique A = hotte ventilateur simple B = hotte ventilateur double

4¼"

To be translated in Spanish Electrical access hole center A = single blower hood B = double blower hood
AB

C

Place this edge against back wall Appuyer ce bord au mur arrière Apoyar este borde contra la pared de atrás

(1) TEMPLATE FOR DUCTING (PRINTED BOTH SIDES)

(2) INSTALLATION BRACKETS**
FOR FRAMED CABINET
(2) INSTALLATION BRACKETS**
FOR FRAMELESS CABINET
** FIND EZ1 BRACKETS
ATTACHED INSIDE OF HOOD
(1) PARTS BAG*** CONTAINING:

(4) NO. 8-18 X 1/2" METAL SCREWS

(6) NO. 8 X 5/8" RD. HD.
WOOD SCREWS

(6) NO. 8 X 1/2" COUNTERSUNK WOOD SCREWS

(1) BULB SUCTION CUP TOOL

*** FIND PARTS BAG BEHIND
THE DAMPER ASSEMBLY INSIDE OF HOOD

(1) GREASE FILTER
(2) SHIELDED HALOGEN BULBS (50W, GU10)
* FIND INSIDE
OF HOOD
(1) 3¼" X 10" DAMPER ASSEMBLY*
(1) 7" ROUND DUCT CONNECTOR (1) PARTS BAG** CONTAINING:
(5) NO. 8 X 5/8" RD. HD.
WOOD SCREWS
(1) BULB SUCTION CUP TOOL
** FIND PARTS BAG BEHIND
THE DAMPER ASSEMBLY INSIDE OF HOOD

INSTALLATION MANUAL
INSTALLATION

10

Prepare the Hood
NOTE: Since this manual covers many range hood models, some details in the following illustrations may sligthly differ from your unit.
1 ] If present, remove all protective polyfilm from the hood and/or parts.
2 ] Using the finger cup or tab, remove the grease filters from the hood by pushing down  and tilting filter out .
B C
3 ] Remove the EZ1 brackets from inside the hood by cutting off the tie wrap (no EZ1 brackets in BKSA1 Series). Remove both screws holding damper assembly to hood. Remove parts bag (captured behind the damper assembly). Remove damper assembly from inside the hood and keep the screws for further use.
SCREWS EZ1 BRACKETS
DAMPER ASSEMBLY
4 ] Remove the wiring cover (shaded part on illustration below) by sliding it out from the hood and set it aside. Remove the light bulbs (under the wiring cover, BKSA1 and BKSH1 Series only).
11

INSTALLATION MANUAL
INSTALLATION

5 ] Remove 7" Round Duct Plate from top/back of hood (see illustration below). Keep the screws for further use.

2 SCREWS

7" ROUND DUCT PLATE

6 ] Remove Electrical Power Cable Knockout from top (vertical exhaust) or back (horizontal exhaust) of hood. Install an appropriate strain relief, 1/2" diameter (not included).
ELECTRICAL POWER CABLE
KNOCKOUT

NON-DUCTED INSTALLATION ONLY
7 ] Remove 3 screws retaining the recirculation cover plate (shaded part in illustration below) to the hood. Discard this plate with its screws.
RECIRCULATION SCREWS COVER PLATE

INSTALLATION MANUAL
INSTALLATION

12

DUCTED INSTALLATION ONLY

8 ] Remove 3¼" x 10" vertical, 3¼" x 10" horizontal, or 7-inch round knockout plate as appropriate for your ducting method (see FIGURES 1 A and 1 B).

FIGURE 1 A
7" ROUND KNOCKOUT PLATE (ALSO REMOVE
VERTICAL KNOCKOUT PLATE)

FIGURE 1 B

3¼" X 10" VERTICAL KNOCKOUT
PLATE

3¼" X 10" HORIZONTAL KNOCKOUT
PLATE

9 ] Attach 3¼" x 10" Damper Assembly on top OR back of hood (if using 3¼" x 10" duct; shaded

part in FIGURE 2 A below) or 7" Round Duct Plate (if using 7-inch round duct, FIGURE 3) over the knockout opening. When installed, the 3¼" x 10" damper assembly must open as

shown in FIGURE 2 B.

FIGURE 2 A
3¼" X 10" DAMPER ASSEMBLY

SCREWS

FIGURE 2 B
TOP/BACK EDGE OF
HOOD

DAMPER FLAP PIVOT

3¼" X 10" DAMPER ASSEMBLY

SCREWS

BACK OF HOOD

DAMPER FLAP PIVOT

INSTALLATION MANUAL
INSTALLATION

FIGURE 3 SCREWS

7" ROUND DUCT PLATE

NOTE: To accommodate off-center ductwork, the 7" round duct plate can be installed up to 1/2" on either side of the hood center.
TIP: Insert a small length of duct over the 3¼" x 10" damper assembly (for rectangular ducting) or 7" round (for round ducting) and seal the joint using aluminum foil duct tape to ease connection with the house ductwork.

13

Prepare the Hood Location

NOTE: Before starting installation, read all the steps of these instructions.

Use the illustration below to identify your kitchen cabinet type.

FRAMED CABINET

FRAMELESS CABINET

INSTALLATION MANUAL
INSTALLATION

14

This manual covers 2 kinds of installation: the standard (without EZ1 brackets) and the EZ1 one-person installation system (using included template and brackets). Please note that the EZ1 one-person installation system is not available for the BKSA1 Series. For the standard installation, go to page 19.
EZ1 one-person installation system

EZ1 installation is designed for use with kitchen cabinets that have the same width designation as the range hood width. If the cabinet is greater than 1/2" wider than the range hood width, please use the standard installation method. 1 ] Use the proper template for vertical OR horizontal disharge (included) for placement of
ductwork and electrical cutout in cabinet or wall. For a non-ducted installation, DO NOT cut a duct access hole, only cut the hole for electrical wiring. If replacing a hood and plan to use the existing duct and electrical, steps 2 to 5 may not be necessary. If so, skip to step 6. 2 ] Measure and mark the hood center line on cabinet bottom. 3 ] Align the center line on template with the hood center line marked on the bottom of the cabinet, placing the edge (where indicated) of the template against back wall. When using with framed cabinet for vertical exhaust installation, fold over rear edge of template equal to the depth of the cabinet frame at the wall (use graduations on template, C locations on template). Tape the template in place. NOTE: When facing the installation, A and B (on template) must be at right.

CABINET FRONT

CABINET FRONT

VERTICAL EXHAUST DUCTING

Use this template for marking; do not attempt to cut out the ducting hole through it. NOTE: These cutouts are clearance holes; they do not need to be the exact size of ducting. Utiliser ce gabarit pour marquer vos repères; ne pas tenter de découper le trou pour le conduit à travers le gabarit. NOTE : Les découpes incluent le jeu nécessaire à l'installation; elles ne doivent pas
être du format exact des conduits.
Use esta plantilla para crear marcados; no trate de cortar el agujero del conducto a través de la plantilla. NOTA: To be translated in Spanish.

C

Bend template along graduated scale when installing to framed cabinet.

Pour une installation sous une

armoire à fond en retrait, utiliser les

lignes pour mesurer l'épaisseur du

décalage causé par le mur de

l'armoire et plier le gabarit en conséquence.

8"

To be translated in Spanish.

CL

MARK WHERE INDICATED FOR THE APPROPRIATE SIZE DUCT OPENING

7" ROUND DUCTING

OR

RECTANGULAR DUCTING = 3¼" x 10"
= 3¼" x 14"

MARQUER LES REPÈRES AUX ENDROITS INDIQUÉS SELON LE FORMAT DE CONDUIT UTILISÉ

OU CONDUIT ROND DE 7 PO

CONDUIT RECTANGULAIRE = 3¼ po x 10 po = 3¼ po x 14 po

TITLE TO BE TRANSLATED IN SPANISH

O CONDUCTO REDONDO DE 7 PULG.

CONDUCTO RECTANGULAR = 3¼ pulg. x 10 pulg. = 3¼ pulg. x 14 pulg.

7½"

Electrical access hole center A = single blower hood B = double blower hood

VERTICAL
10½"
14½"
C

Centre du trou pour fil
EXHAUSTd'alimentation électrique A = hotte ventilateur simple B = hotte ventilateur double

4¼"

To be translated in Spanish Electrical access hole center A = single blower hood B = double blower hood
AB

C

Place this edge against back wall Appuyer ce bord au mur arrière Apoyar este borde contra la pared de atrás

C
P

FOLD TEMPLATE ALONG GRADUATED
SCALE WHEN INSTALLING TO FRAMED
CABINET.

Use this template for marking; do not attempt to cut out the ducting hole through it. NOTE: These cutouts are clearance holes; they do not need to be the exact size of ducting. Utiliser ce gabarit pour marquer vos repères; ne pas tenter de découper le trou pour le conduit à travers le gabarit. NOTE : Les découpes incluent le jeu nécessaire à l'installation; elles ne doivent pas
être du format exact des conduits.
Use esta plantilla para crear marcados; no trate de cortar el agujero del conducto a través de la plantilla. NOTA: To be translated in Spanish.

C

Bend template along graduated scale when installing to framed cabinet.

Pour une installation sous une

armoire à fond en retrait, utiliser les

lignes pour mesurer l'épaisseur du

décalage causé par le mur de

l'armoire et plier le gabarit en conséquence.

8"

To be translated in Spanish.

CL

MARK WHERE INDICATED FOR THE APPROPRIATE SIZE DUCT OPENING

7" ROUND DUCTING

OR

RECTANGULAR DUCTING = 3¼" x 10"
= 3¼" x 14"

MARQUER LES REPÈRES AUX ENDROITS INDIQUÉS SELON LE FORMAT DE CONDUIT UTILISÉ

OU CONDUIT ROND DE 7 PO

CONDUIT RECTANGULAIRE = 3¼ po x 10 po = 3¼ po x 14 po

TITLE TO BE TRANSLATED IN SPANISH

O CONDUCTO REDONDO DE 7 PULG.

CONDUCTO RECTANGULAR = 3¼ pulg. x 10 pulg. = 3¼ pulg. x 14 pulg.

7½"

Electrical access hole center A = single blower hood B = double blower hood

VERTICAL
10½"
14½"
C

Centre du trou pour fil
EXHAUSTd'alimentation électrique A = hotte ventilateur simple B = hotte ventilateur double

4¼"

To be translated in Spanish Electrical access hole center A = single blower hood B = double blower hood
AB

C

CENTER LINE

A C

ELECTRICAL ACCESS HOLE LOCATION (A) (IN CABINET BOTTOM)

CENTER LINE

Place this edge against cabinet bottom. Appuyer ce bord contre le bas de l'armoire. Apoyar este borde contra la base del armario.
CL

AB
Electrical access hole center A = single blower hood B = double blower hood
Centre du trou pour fil d'alimentation électrique A = hotte ventilateur simple B = hotte ventilateur double
To be translated in Spanish Electrical access hole center A = single blower hood B = double blower hood

A

Use this template for marking; do not attempt to cut out the ducting hole through it. NOTE: These cutouts are clearance holes; they do not need to be the exact size of ducting.
Utiliser ce gabarit pour marquer vos repères; ne pas tenter de découper le trou pour le conduit à travers le gabarit. NOTE :Les découpes incluent le jeu nécessaire à l'installation; elles ne doivent pas
être du format exact des conduits.
Use esta plantilla para crear marcados; no trate de cortar el agujero del conducto a través de la plantilla. NOTA: To be translated in Spanish.

MARK WHERE INDICATED FOR THE APPROPRIATE SIZE DUCT OPENING

MARQUER LES REPÈRES AUX ENDROITS INDIQUÉS SELON LE FORMAT DE CONDUIT UTILISÉ

RECTANGULAR DUCTING = 3¼" x 10" = 3¼" x 14"

CONDUIT RECTANGULAIRE = 3¼ po x 10 po = 3¼ po x 14 po

TITLE TO BE TRANSLATED IN SPANISH

CONDUCTO RECTANGULAR
= 3¼ pulg. x 10 pulg. = 3¼ pulg. x 14 pulg.

HORIZONTAL EXHAUST

Electrical access hol A = single blower ho B = double blower
Centre du tr d'alim

ELECTRICAL

ACCESS HOLE

LOCATION (A)

(IN WALL)

4 ] Drill a 1/8" dia. pilot hole for house wiring, at A location on template.
5 ] Use a sharp pencil or 1/8" drill bit to mark the locations for the appropriate duct access holes (16 locations for 7" round duct, or 4 corner locations for rectangular duct). Remove the template.
6 ] Draw the border for the exhaust ducting by linking its marks (16 for round duct and 4 for rectangular duct), then cut the opening in the cabinet bottom (vertical exhaust) or in the wall (horizontal exhaust). Drill the house wiring hole by using a 1½" hole saw centered with the pilot hole previously made in 4.
7 ] Install the proper installation brackets according to the type of cabinet (framed or frameless). See below.
FRAMED CABINET

Refer to the marking on the brackets to determine the correct installation side and

orientation.

X

Y

7/64"
Z

INSTALLATION MANUAL
INSTALLATION

Mate the corresponding bracket to the cabinet side frame, while placing rear end
of bracket against the wall. Use a pencil to mark 3 holes (there are 6 holes but only 3 are necessary).
Remove the bracket. Using a 7/64" drill bit, drill 3 holes where marked.
Assemble the bracket to the side frame using a Phillips screwdriver and 3 provided
no. 8 x 5/8" wood screws. Repeat for the other side frame.

15

FRAMELESS CABINET

Refer to the marking on brackets to determine the correct installation side and orientation.

X

Y

Z

3 X

[

\

7/64"

INSTALLATION MANUAL
INSTALLATION

16

Align the corresponding bracket to the cabinet side, while placing rear end of bracket
against the wall. Draw a line on the outer edge of the bracket (as shown).
Slide the bracket towards the center of cabinet and align the outside edge of the
bracket with the marked line, keeping the rear end edge leaning on the wall.
 Use a pencil to mark 3 holes.
Remove the bracket. Using a 7/64" drill bit, drill 3 holes where marked.
Assemble the bracket to the cabinet bottom using a Phillips screwdriver and 3 provided
countersunk wood screws. Repeat for the other cabinet side.

Install the Hood (EZ1 Bracket)
NOTE: The following procedure applies to both framed or frameless cabinet installations.
1 ] Run house power cable between service panel and hood location.
2 ] There are 2 pairs of recessed holes on each side of the top of the hood (on rear: A and B, on front C and D on illustration below); these holes allow the range hood to hang on the brackets (previously installed).
A C
B D

HORIZONTAL EXHAUST INSTALLATION ONLY
3 ] Temporarily hang the hood on the brackets using its 2 recessed REAR HOLES (A and B). While holding the hood, run the house power cable into the hood through the strain relief previously installed in step 6 on page 12.

A B
4 ] Unhook the rear holes from the brackets and hang the hood using its 2 recessed FRONT HOLES (C and D). While holding the hood, attach the power cable to the hood using the strain relief.
VERTICAL EXHAUST INSTALLATION ONLY 5 ] Hang the hood on the brackets using the 2 recessed FRONT HOLES (C and D). While
holding the hood, run the house power cable into the hood through the strain relief previously installed in step 6 on page 12. Attach power cable to the hood.
DUCTED INSTALLATION ONLY
6 ] Connect the ductwork to the hood and use metal foil duct tape to make joints secure and air-tight. Make sure the damper assembly (or round duct plate) enters the ductwork and that the damper opens and closes freely.

INSTALLATION MANUAL
INSTALLATION

17

7 ] For framed cabinet, secure the hood to the EZ1 brackets using 4 no. 8-18 x 1/2" metal screws (included in parts bag). Insert 2 screws per side, in the slots (as shown in insets on illustration below).

8 ] For frameless cabinet, secure the hood to the cabinet using 4 no. 8 x 5/8" round head wood screws (included in parts bag). Insert 2 screws per side, in the slots (as shown in insets on illustration below).

FRAMED CABINET

FRAMELESS CABINET

METAL SCREWS

WOOD SCREWS

INSTALLATION MANUAL
INSTALLATION

18

Standard Installation (without EZ1 brackets)
1 ] Use the proper diagram below for placement of ductwork and electrical cutout in cabinet or wall. For a non-ducted installation, DO NOT cut a duct access hole, only cut the hole for electrical wiring.

HOOD MOUNTING SCREWS (4)

3¼" X 10" VERTICAL DUCTING

12" (30" HOOD) 15" (36" HOOD)
CABINET FRONT

12" (30" HOOD) 15" (36" HOOD)

47/16"

CABINET BOTTOM 7³/16"

5¼" 5¼"

VERTICAL DUCT ACCESS HOLE

1"

3/4"

1015/16" 1½"

WOOD SHIMS (RECESSED-BOTTOM
CABINETS ONLY)

CENTER LINE

ELECTRICAL ACCESS HOLE (IN CABINET BOTTOM)

WOOD SHIMS (RECESSED-BOTTOM

3¼" X 10" HORIZONTAL DUCTING

CABINETS ONLY) CABINET FRONT 13/16"

3/16"

3" CABINET

HORIZONTAL DUCT ACCESS HOLE

BOTTOM

5¼"

5¼"

7³/16"

12" (30" HOOD)

12" (30" HOOD)

15" (36" HOOD)

15" (36" HOOD)

HOOD MOUNTING SCREWS (4)

CENTER LINE

ELECTRICAL ACCESS HOLE
(IN WALL)

HOOD MOUNTING SCREWS (4)

7-IN. ROUND VERTICAL DUCTING

12" (30" HOOD) 15" (36" HOOD)

12" (30" HOOD) 15" (36" HOOD)

7-IN. ROUND DUCT
ACCESS
4¹¹/16" HOLE

7³/16"
8" DIA. HOLE

1"

1015/16" 1½"

WOOD SHIMS (RECESSED-BOTTOM
CABINETS ONLY)

ELECTRICAL ACCESS HOLE (IN CABINET BOTTOM)

2 ] Install part-way four (4) ROUND HEAD no. 8 x 5/8" mounting screws into shims/cabinet, according to the proper diagram above. (Mounting screws are included in parts bag, but wood shims and shim mounting screws are not included).

INSTALLATION MANUAL
INSTALLATION

19

Install the Hood (Standard Installation)
1 ] Run house power cable between service panel and hood location. Run the house power cable into the hood through the strain relief previously installed in step 6 on page 12.
2 ] Hang hood from (4) mounting screws previously installed. Slide hood back towards wall until mounting screw heads are engaged in narrow end of keyhole slots in top of hood. Tighten screws securely. Attach power cable to the hood using the strain relief.
DUCTED INSTALLATION ONLY
3 ] Connect ductwork to hood and use metal foil duct tape to make joints secure and air-tight. Make sure the damper assembly (or round duct plate) enters the ductwork and that the damper opens and closes freely.
20

INSTALLATION MANUAL
INSTALLATION

Connect the Wiring
! WARNING
Risk of electric shock. Electrical wiring must be done by qualified personnel in accordance with all applicable codes and standards. Before connecting wires, switch power off at service panel and lock service disconnecting means to prevent power from being switched on accidentally.

HOUSE POWER CABLE

MOTOR GROUND WIRE
GROUND SCREW

1 ] Connect House Power Cable to range hood wiring: BLACK to BLACK, WHITE to WHITE and GREEN or bare wire under GREEN ground screw.

SCREW

TABS ON INNER TOP OF HOOD ENGAGED IN WIRING COVER SLOTS.

2 ] Reinstall wiring cover and attach it to the hood using its retaining screw.
! CAUTION
Ensure both tabs on inner top of hood are engaged in their corresponding slots in wiring cover. Also, take care not to pinch wires while reinstalling wiring cover.

INSTALLATION MANUAL
INSTALLATION

21

Light Bulbs (BKSA1 and BKSH1 Series only)
The BKSA1 and BKSH1 Series range hoods require two shielded Halogen Bulbs (120 V, 50 W max., MR16 or PAR16 with GU10 base), included.

! WARNING
Do not touch lamps during or soon after operation. Burns may occur. In order to prevent the risk of personal injury, only install shielded halogen lamps. Also, never install a cool beam, a dichroic lamp, a lamp not suitable for use in recessed luminaires or identified for use in enclosed fixtures.

BULB LEADS

BULB LEAD GROOVES (IN SOCKET)

SUCTION CUP TOOL

1 ] Align the bulb leads with the small indentations located on the border of the lamp location on hood (see inset above), then install the bulbs by placing the bulb leads into their grooves in the socket.
2 ] Gently push upwards and turn clockwise until secure.
NOTE: The Suction Cup Tool (included with hood) can be used to install and remove light bulbs. Press suction cup tool on bulb and rotate counterclockwise to remove bulb or clockwise to install bulb.
! CAUTION
Most GU10 LED replacement bulbs commonly found in the market are not designed for use in a cooking environment and might not perform as advertised. Their usage with this product is not recommended.

INSTALLATION MANUAL
INSTALLATION

22

Install the Filter(s)
Ducted Installation Only: Re-install grease filter(s) removed in step 2 on page 11, under "Prepare the Hood". Non-ducted Installation Only: According to your range hood model, purchase one or two non-ducted filters from your local distributor or retailer (see product specification label for filter type). Attach the non-ducted filter(s) following instructions packed with the non-ducted filter(s).

120 V AC

INSTALLATION MANUAL
WIRING DIAGRAMS

BKDB1 SERIES
23

12 34 56
J6
Override

User interface mounted to J10 on back of control board.

J10
Interface

1
2 3 4
84 73 62 51

J4

LED

Power, Motor Transformer

J1

5 4 3 2 1
7 6 5 4 3 2 1
Control Board

J2

Line Neutral Ground

BK W

BK BL BN BN/W

COLOR CODE

BLACK

G/Y

BLUE

O

BROWN

R

BROWN/WHITE

W

BK

R

GREEN/YELLOW ORANGE RED WHITE
W

LED LED

R R

BL BL
BK

BK W
R (Low) O (Medium)
BK (High) W
G/Y

FAN MOTOR

6

5

R

4O 3 BK

2 G/Y

1

W

BN BN/W

BKDEG1 SERIES
24

INSTALLATION MANUAL
WIRING DIAGRAMS

12 34 56
J6
Override

BK BL BN BN/W

COLOR CODE

BLACK

G/Y

BLUE

O

BROWN

R

BROWN/WHITE

W

GREEN/YELLOW ORANGE RED WHITE

User interface mounted to J10 on back of control board.

J10
Interface

1
2 3 4
84 73 62 51

J4

Line Neutral Ground

5 4 3 2 1 7 6 5 4 3 2 1
Control Board
BK W

J2
Power, Motor

J1
Transformer

R R
BL BL BK

2 BK LED

R

1

1

W driver BK 2

R BK
W

W

LED LED

W BK
BL
R (Low) O (Medium)
BK (High) W
G/Y

FAN MOTOR

6

5

R

4O

3 BK

2 G/Y

1

W

BN BN/W

120 V AC

BKSA1 AND BKSH1 SERIES
25

BK

BLACK

BL

BLUE

BN

BROWN

COLOR CODE

BN/W G/Y O

BROWN/WHITE GREEN/YELLOW ORANGE

R

RED

W

WHITE

Y

YELLOW

Light Switch 1

Y (Low)

2

BL (High)

BK

BK BK Motor Switch 1
2

Line

Neutral

Ground

G/Y

W BK
W

R (Low)

BK (High)

W

W

FAN MOTOR

6

5

R

4O 3 BK

2 G/Y

1W

BN BN/W

120 V AC

INSTALLATION MANUAL
WIRING DIAGRAMS

BKDB1 SERIES

D

E

F G

C B K
J
I H

INSTALLATION MANUAL
SERVICE PARTS

26

KEY NO.
1
2 3 4 5 6 7 8 9
10
* *
*
*
* * *

PART NO.

DESCRIPTION

30" BLACK

S97020029 RECIRCULATION COVER PLATE, BLACK (INCLUDING SCREWS) 1

S97020030 RECIRCULATION COVER PLATE, WHITE (INCLUDING SCREWS)

S97020031

RECIRCULATION COVER PLATE, STAINLESS STEEL (INCLUDING SCREWS)

SR680508 7'' ROUND DUCT PLATE (INCLUDING SCREWS)

1

S97020534 3¼" X 10" DAMPER ASSEMBLY (INCLUDING SCREWS)

1

S97020408 BLOWER MOTOR (INCLUDING 4 SCREWS AND 1 CAPACITOR)

1

S97020407 FANPELLER (INCLUDING ITEM 6)

1

SR99420635 CLIP FOR FANPELLER

1

S99010434-002 GREASE FILTER-MICRO MESH - TYPE C2 (SET OF 2)

1

S99010434-003 GREASE FILTER-MICRO MESH - TYPE D2 (SET OF 2)

S97020444 LED MODULE (PAIR)

1

S97020445 TRANSFORMER 24 V 18 VA (WITH SCREWS)

1

S97020431 CAPTOUCH CONTROL LED, STAINLESS (WITH SCREWS)

S97020432 CAPTOUCH CONTROL LED, WHITE (WITH SCREWS)

S97020433 CAPTOUCH CONTROL LED, BLACK (WITH SCREWS)

1

S97020452 WIRE HARNESS

1

S98011637 WIRING COVER

1

PARTS BAG INCLUDING: 4 METAL SCREWS NO. 8-18 X 1/2",

S97020360 6 ROUND HEAD NO. 8 X 5/8" WOOD SCREWS,

1

6 NO. 8 X 1/2" COUNTERSUNK SCREWS

S97020466

NON-DUCTED FILTER - TYPE XC (SET OF 2) (NON-DUCTED INSTALLATION ONLY)

1

S97020467

NON-DUCTED FILTER - TYPE XD (SET OF 2) (NON-DUCTED INSTALLATION ONLY)

S99527587 NON-DUCTED FILTER CLIP KIT (INCLUDES 4 CLIPS)

1

S97020470 EASY INSTALL KIT (INCLUDING HARDWARE)

1

30" STAINLESS
1 1 1 1 1 1 1
1 1 1
1 1
1
1
1 1

QUANTITY 30" 36" 36" WHITE BLACK STAINLESS
1 1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

36" WHITE
1
1 1 1 1 1
1 1 1
1
1 1
1
1 1 1

* ITEM NOT SHOWN.

REPLACEMENT PARTS AND REPAIRS
In order to ensure your unit remains in good working condition, you must use Broan-NuTone LLC or Broan-NuTone Canada ULC genuine replacement parts only. Broan-NuTone LLC or Broan-NuTone Canada ULC genuine replacement parts are specially designed for each unit and are manufactured to comply with all the applicable certification standards and maintain a high standard of safety. Any third party replacement part used may cause serious damage and drastically reduce the performance level of your unit, which will result in premature failing. Broan-NuTone LLC and Broan-NuTone Canada ULC recommend to contact a certified service depot for all replacement parts and repairs.

BKDEG1 SERIES

D

E

F G

C
B L
K

I

J

H

KEY NO.

PART NO.

DESCRIPTION

S97020030 RECIRCULATION COVER PLATE, WHITE (INCLUDING SCREWS)

1

S97020031 RECIRCULATION COVER PLATE, STAINLESS STEEL (INCL. SCREWS)

S97020029 RECIRCULATION COVER PLATE, BLACK (INCLUDING SCREWS)

2

SR680508 7'' ROUND DUCT PLATE (INCLUDING SCREWS)

3

S97020534 3¼" X 10" DAMPER ASSEMBLY (INCLUDING SCREWS)

4

S97020409 BLOWER MOTOR (INCLUDING 4 SCREWS AND 1 CAPACITOR)

5

S97020407 FANPELLER (INCLUDING ITEM 6)

6 SR99420635 CLIP FOR FANPELLER

7 S99010431-002 GREASE FILTER - MICRO MESH - OBLONG TYPE C3 (SET OF 2)

8

S97020444 LED MODULE (PAIR)

9

S97020445 TRANSFORMER 24 V 18 VA (WITH SCREWS)

10 S97020446 LED DRIVER ES (WITH SCREWS)

S97020434 CAPTOUCH CONTROL LED ES, STAINLESS (WITH SCREWS)

11 S97020435 CAPTOUCH CONTROL LED ES, WHITE (WITH SCREWS)

S97020436 CAPTOUCH CONTROL LED ES, BLACK (WITH SCREWS)

*

S97020455 WIRE HARNESS

*

S98011637 WIRING COVER

PARTS BAG INCLUDING: 4 METAL SCREWS NO. 8-18 X 1/2",

*

S97020360 6 ROUND HEAD NO. 8 X 5/8" WOOD SCREWS,

6 NO. 8 X 1/2" COUNTERSUNK SCREWS

*

S97020466

NON-DUCTED FILTER - TYPE XC (SET OF 2) (NON-DUCTED INSTALLATION ONLY)

*

S99527587 NON-DUCTED FILTER CLIP KIT (INCLUDES 4 CLIPS)

*

S97020470 EASY INSTALL KIT (INCLUDING HARDWARE)

* ITEM NOT SHOWN.

30" BLACK
1 1 1 1 1 1 1 1 1 1
1 1 1

QUANTITY 30"
STAINLESS
1
1 1 1 1 1 1 1 1 1 1
1 1

30" WHITE
1
1 1 1 1 1 1 1 1 1
1
1 1

1

1

1

1

1

1

1

1

1

1

1

1

REPLACEMENT PARTS AND REPAIRS
In order to ensure your unit remains in good working condition, you must use Broan-NuTone LLC or Broan-NuTone Canada ULC genuine replacement parts only. Broan-NuTone LLC or Broan-NuTone Canada ULC genuine replacement parts are specially designed for each unit and are manufactured to comply with all the applicable certification standards and maintain a high standard of safety. Any third party replacement part used may cause serious damage and drastically reduce the performance level of your unit, which will result in premature failing. Broan-NuTone LLC and Broan-NuTone Canada ULC recommend to contact a certified service depot for all replacement parts and repairs.

INSTALLATION MANUAL
SERVICE PARTS

27

BKSH1 SERIES







  



INSTALLATION MANUAL
SERVICE PARTS

28

KEY NO.

PART NO.

DESCRIPTION

S97020030 RECIRCULATION COVER PLATE, WHITE (INCLUDING SCREWS)

1

S97020031 RECIRCULATION COVER PLATE, STAINLESS STEEL (INCLUDING SCREWS)

S97020029 RECIRCULATION COVER PLATE, BLACK (INCLUDING SCREWS)

2

SR680508 7'' ROUND DUCT PLATE (INCLUDING SCREWS)

3

S97020534 3¼" X 10" DAMPER ASSEMBLY (INCLUDING SCREWS)

4

S97020408 BLOWER MOTOR (INCLUDING 4 SCREWS AND 1 CAPACITOR)

5

S97020407 FANPELLER (INCLUDING ITEM 6)

6 SR99420635 CLIP FOR FANPELLER

7 S99010434-002 GREASE FILTER - MICRO MESH - TYPE C2 (SET OF 2)

S97020422 ELONGATED ROCKER SWITCH, GREY (INCLUDING SCREWS)

8

S97020421 ELONGATED ROCKER SWITCH, WHITE (INCLUDING SCREWS)

S97020420 ELONGATED ROCKER SWITCH, BLACK (INCLUDING SCREWS)

9

S97020448 WIRE HARNESS

*

S98011637 WIRING COVER

PARTS BAG INCLUDING: 4 METAL SCREWS NO. 8-18 X 1/2",

*

S97020292 6 ROUND HEAD NO. 8 X 5/8" WOOD SCREWS,

6 NO. 8 X 1/2" COUNTERSUNK SCREWS, 1 SUCTION CUP TOOL

*

S97020466

NON-DUCTED FILTER - TYPE XC (SET OF 2) (NON-DUCTED INSTALLATION ONLY)

*

S99527587 NON-DUCTED FILTER CLIP KIT (INCLUDES 4 CLIPS)

*

S97020470 EASY INSTALL KIT (INCLUDING HARDWARE)

*

SV05921 SHIELDED HALOGEN BULB 50 W, GU10

* ITEM NOT SHOWN.

QUANTITY 30" 30" STAINLESS WHITE
1 1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

30" BLACK
1 1 1 1 1 1 1
1 1 1

1

1

1

1

1

1

1

1

1

1

1

1

2

2

2

REPLACEMENT PARTS AND REPAIRS
In order to ensure your unit remains in good working condition, you must use Broan-NuTone LLC or Broan-NuTone Canada ULC genuine replacement parts only. Broan-NuTone LLC or Broan-NuTone Canada ULC genuine replacement parts are specially designed for each unit and are manufactured to comply with all the applicable certification standards and maintain a high standard of safety. Any third party replacement part used may cause serious damage and drastically reduce the performance level of your unit, which will result in premature failing. Broan-NuTone LLC and Broan-NuTone Canada ULC recommend to contact a certified service depot for all replacement parts and repairs.

BKSA1 SERIES

















KEY NO.

PART NO.

DESCRIPTION

S97020029 RECIRCULATION COVER PLATE, BLACK (INCLUDING SCREWS)

1

S97020030 RECIRCULATION COVER PLATE, WHITE (INCLUDING SCREWS)

S97020031 RECIRCULATION COVER PLATE, STAINLESS STEEL (INCLUDING SCREWS)

2

SR680508 7'' ROUND DUCT PLATE (INCLUDING SCREWS)

3

S97020534 3¼" X 10" DAMPER ASSEMBLY (INCLUDING SCREWS)

4

S97020408 BLOWER MOTOR (INCLUDING 4 SCREWS AND 1 CAPACITOR)

5

S97020407 FANPELLER (INCLUDING ITEM 6)

6 SR99420635 CLIP FOR FANPELLER

7

S99010436 GREASE FILTER - OPEN MESH - TYPE A0 (1 PC.)

S99030355 ROCKER SWITCH, WHITE (SET OF 2)

8

S99030356 ROCKER SWITCH, BLACK (SET OF 2)

S99030367 ROCKER SWITCH, GREY (SET OF 2)

9

S97020448 WIRE HARNESS

*

S98011637 WIRING COVER

*

S97018623

PARTS BAG INCLUDING: 5 ROUND HEAD NO. 8 X 5/8" WOOD SCREWS, 1 SUCTION CUP TOOL

*

S97020464

NON-DUCTED FILTER - TYPE XA (1 PC.) (NON-DUCTED INSTALLATION ONLY)

*

S99527587 NON-DUCTED FILTER CLIP KIT (INCLUDES 4 CLIPS)

*

SV05921 SHIELDED HALOGEN BULB 50 W, GU10

* ITEM NOT SHOWN.

QUANTITY
30" 30" STAINLESS WHITE

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

30" BLACK
1
1 1 1 1 1 1
1
1 1

1

1

1

1

1

1

1

1

1

2

2

2

REPLACEMENT PARTS AND REPAIRS
In order to ensure your unit remains in good working condition, you must use Broan-NuTone LLC or Broan-NuTone Canada ULC genuine replacement parts only. Broan-NuTone LLC or Broan-NuTone Canada ULC genuine replacement parts are specially designed for each unit and are manufactured to comply with all the applicable certification standards and maintain a high standard of safety. Any third party replacement part used may cause serious damage and drastically reduce the performance level of your unit, which will result in premature failing. Broan-NuTone LLC and Broan-NuTone Canada ULC recommend to contact a certified service depot for all replacement parts and repairs.

INSTALLATION MANUAL
SERVICE PARTS

29

INSTALLATION MANUAL
WARRANTY

30

Limited Warranty Warranty Period and Exclusions: Broan-NuTone LLC and Broan-NuTone Canada ULC (either being the "Company") warrants to the original consumer purchaser of its product ("you") that the product (the "Product") will be free from material defects in the Product or its workmanship for a period of one (1) year from the date of original purchase (or such longer period as may be required by applicable law). For Range Hood Product that includes built-in LED modules, the Company warrants the LED modules and driver to be free from material defects for a period of three (3) years from the date of purchase. The limited warranty period for any replacement parts provided by the Company and for any Products repaired or replaced under this limited warranty shall be the remainder of the original warranty period (or such longer period as may be required by applicable law). This warranty does not cover fluorescent lamp starters, tubes, halogen and incandescent bulbs, fuses, filters, ducts, roof caps, wall caps and other accessories for ducting that may be purchased separately and installed with the Product. This warranty also does not cover (a) normal maintenance and service, (b) normal wear and tear, (c) any Products or parts which have been subject to misuse, abuse, abnormal usage, negligence, accident, improper or insufficient maintenance, storage or repair (other than repair by the Company), (d) damage caused by faulty installation, or installation or use contrary to recommendations or instructions, (e) any Product that has been moved from its original point of installation, (f) damage caused by environmental or natural elements, (g) damage in transit, (h) natural wear of finish, (i) Products in commercial or nonresidential use, or (j) damage caused by fire, flood or other act of God or (k) Products with altered, defaced or removed serial numbers. This warranty covers only Products sold to original consumers in the United States and Canada by the Company or its U.S. and Canadian distributors authorized by the Company. This warranty supersedes all prior warranties and, subject to applicable law, is not transferable from the original consumer purchaser. No Other Warranties: This Limited Warranty contains the Company's sole obligation and your sole remedy for defective products. The foregoing warranties are exclusive and in lieu of any other warranties and conditions, express or implied. THE COMPANY DISCLAIMS AND EXCLUDES ALL OTHER EXPRESS WARRANTIES AND CONDITIONS, AND DISCLAIMS AND EXCLUDES ALL WARRANTIES AND CONDITIONS IMPLIED BY LAW, INCLUDING WITHOUT LIMITATION THOSE OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. To the extent that applicable law prohibits the exclusion of implied warranties or conditions, the duration of any applicable implied warranty or condition is limited to the period specified for the express warranty above. Some jurisdictions do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you. Any oral or written description of the Product is for the sole purpose of identifying it and shall not be construed as an express warranty. Whenever possible, each provision of this Limited Warranty shall be interpreted in such manner as to be effective and valid under applicable law, but if any provision is held to be prohibited or invalid, such provision shall be ineffective only to the extent of such prohibition or invalidity, without invalidating the remainder of such provision or the other remaining provisions of the Limited Warranty. Remedy: During the applicable limited warranty period, the Company will, at its option, provide replacement parts for, or repair or replace, without charge, any Product or part thereof, to the extent the Company finds it to be covered by and in breach of this limited warranty under normal use and service. The Company will ship the repaired or replaced Product or replacement parts to you at no charge.You are responsible for all costs for removal, reinstallation and shipping, insurance or other freight charges incurred in the shipment of the Product or part to the Company. If you must send the Product or part to the Company, as instructed by the Company, you must properly pack the Product or part--the Company is not responsible for damage in transit. The Company reserves the right to utilize reconditioned, refurbished, repaired or remanufactured Products or parts in the warranty repair or replacement process. Such Products and parts will be comparable in function and performance to an original Product or part and warranted for the remainder of the original warranty period (or such longer period as may be required by applicable law). Company reserves the right, in its sole discretion, to refund the money actually paid by you for the Product in lieu of repair or replacement. If the Product or component is no longer available, replacement may be made with a similar product of equal or greater value, at Company's sole discretion. This is your sole and exclusive remedy for breach of this limited warranty. Exclusion of Damages: THE COMPANY'S OBLIGATION TO PROVIDE REPLACEMENT PARTS, OR REPAIR, REPLACE OR REFUND, AT THE COMPANY'S OPTION, SHALL BE YOUR SOLE AND EXCLUSIVE REMEDY UNDER THIS LIMITED WARRANTY AND THE COMPANY'S SOLE AND EXCLUSIVE OBLIGATION. THE COMPANY SHALL NOT BE LIABLE FOR INCIDENTAL, INDIRECT, CONSEQUENTIAL OR SPECIAL DAMAGES ARISING OUT OF OR IN CONNECTION WITH THE PRODUCT, ITS USE OR PERFORMANCE. Incidental damages include but are not limited to such damages as loss of time and loss of use. Consequential damages include but are not limited to the cost of repairing or replacing other property which was damaged if the Product does not work properly. THE COMPANY SHALL NOT BE LIABLE TO YOU, OR TO ANYONE CLAIMING UNDER YOU, FOR ANY OTHER OBLIGATIONS OR LIABILITIES, INCLUDING, BUT NOT LIMITED TO, OBLIGATIONS OR LIABILITIES ARISING OUT OF BREACH OF CONTRACT OR WARRANTY, NEGLIGENCE OR OTHER TORT OR ANY THEORY OF STRICT LIABILITY, WITH RESPECT TO THE PRODUCT OR THE COMPANY'S ACTS OR OMISSIONS OR OTHERWISE. Some jurisdictions do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. This warranty gives you specific legal rights, and you may also have other rights, which vary from jurisdiction to jurisdiction. The disclaimers, exclusions, and limitations of liability under this warranty will not apply to the extent prohibited by applicable law. This warranty covers only replacement or repair of defective Products or parts thereof at the Company's main facility and does not include the cost of field service travel and living expenses. Any assistance the Company provides to or procures for you outside the terms, limitations or exclusions of this limited warranty will not constitute a waiver of such terms, limitations or exclusions, nor will such assistance extend or revive the warranty. The Company will not reimburse you for any expenses incurred by you in repairing or replacing any defective Product, except for those incurred with the Company's prior written permission. How to Obtain Warranty Service: To qualify for warranty service, you must (a) notify the Company at the address or telephone number stated below within seven (7) days of discovering the covered defect, (b) give the model number and part identification and (c) describe the nature of any defect in the Product or part. At the time of requesting warranty service, you must present evidence of the original purchase date. If you cannot provide a copy of the original written limited warranty, then the terms of the Company's most current written limited warranty for your particular product will control. The most current limited written warranties for the Company's products can be found at www.broan.com and www.broan.ca. Broan-NuTone LLC 926 West State Street, Hartford, WI 53027 www.broan.com 800-637-1453 Broan-NuTone Canada ULC, 1140 Tristar Drive, Mississauga, Ontario, Canada L5T 1H9 www.broan.ca 1-877-896-1119


PScript5.dll Version 5.2.2 (C) 2018 Retailer Web Services LLC, all rights reserved.

Search Any Device: