Test Report of 5G Wi-Fi Part 1
Beijing Xiaomi Electronics Co.,Ltd MITVMDZ28AA Xiaomi Box 4K which supports Bluetooth and Wi-Fi 2AIMRMITVMDZ28AA 2AIMRMITVMDZ28AA mitvmdz28aa
Not Your Device? Search For Manuals or Datasheets below:
File Info : application/pdf, 34 Pages, 3.43MB
Document DEVICE REPORTGetApplicationAttachment.html?id=6124362Report Number: 68.950.22.0676.01 FCC/ISED - TEST REPORT Report Number Model Product Type Applicant Address Manufacturers Address Test Result Total pages including Appendices : 68.950.22.0676.01 Date of Issue: August 18, 2022 : MDZ-28-AA : Xiaomi Box 4K : Beijing Xiaomi Electronics Co., Ltd : Room 802, 8F, Building 5, No.15, Kechuang Ten Street, Beijing : Economic & Technological Development Zone Beijing China 100085 : Beijing Xiaomi Electronics Co., Ltd : Room 802, 8F, Building 5, No.15, Kechuang Ten Street, Beijing : Economic & Technological Development Zone Beijing China 100085 : Positive Negative : 304 Any use for advertising purposes must be granted in writing. This technical report may only be quoted in full. This report is the result of a single examination of the object in question and is not generally applicable evaluation of the quality of other products in regular production. For further details, please see testing and certification regulation, chapter A-3.4. EMC_SZ_FR_24.00 IC Release 2017-03-13 TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District, Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299 Page 1 of 304 Report Number: 68.950.22.0676.01 1 Table of Contents 1 Table of Contents 2 2 Details about the Test Laboratory 3 3 Description of the Equipment Under Test 4 4 Summary of Test Standards 5 5 Summary of Test Results 6 6 General Remarks 7 7 Test setups 8 8 Systems test configuration 9 9 Technical Requirements 10 9.1 Conducted emission AC power port 10 9.2 Emission bandwidth 13 9.3 Maximum Conducted Output Power & EIRP 62 9.4 Peak Power Spectral Density 66 9.5 Unwanted Emissions 119 9.6 Band Edge 229 9.7 Frequency Stability 287 9.8 Dynamic Frequency Selection (DFS) 294 10 Test Equipment List 303 11 System Measurement Uncertainty 304 EMC_SZ_FR_24.00 IC Release 2017-03-13 TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District, Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299 Page 2 of 304 Report Number: 68.950.22.0676.01 2 Details about the Test Laboratory Details about the Test Laboratory Test Site 1 Company name: TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building 12 & 13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District Shenzhen 518052 P.R. China Telephone: Fax: 86 755 8828 6998 86 755 8288 5299 FCC Registration No.: ISED test site number: 514049 10320A EMC_SZ_FR_24.00 IC Release 2017-03-13 TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District, Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299 Page 3 of 304 Report Number: 68.950.22.0676.01 3 Description of the Equipment Under Test Description of the Equipment Under Test Product: Xiaomi Box 4K Model no/HVIN/PMN: MDZ-28-AA FVIN: R104 FCC ID: 2AIMRMITVMDZ28AA IC: 25940-MITVMDZ28AA Options and accessories: Rating: RF transmission frequency: Antenna Type: Antenna Gain: Description of the EUT Adapter, HDMI Cable 5.2VDC, 2.1A(Supplied by AC/DC Adapter) Adapter information: Model: AD-0100520210US-1 Input: 100-240V~50/60Hz, 0.3A Output: 5.2VDC, 2.1A, 10.92W Bluetooth BR+EDR: 2402-2480MHz Bluetooth LE: 2402-2480MHz Wi-Fi 2.4G: 2412-2462MHz Wi-Fi 5G: 5150MHz~5350MHz; Wi-Fi 5G: 5470MHz 5725MHz Wi-Fi 5G: 5725MHz 5850MHz. Note: until further notice, device subject to this section shall not be capable of transmitting in the band 5600-5650MHz. This restriction is for the protection of Environment Canada's weather radars operating in this band. Integrated Antenna Bluetooth: 0.5dBi Wi-Fi 2.4G Ant 1: 0.5dBi, Ant 2: 0.5dBi Wi-Fi 5G Ant 1: 2dBi, Ant 2: 2dBi The EUT is a Xiaomi Box 4K with Bluetooth, 2.4GHz Wi-Fi and 5GHz Wi-Fi function. Bluetooth TX and RX range is 2402-2480MHz, Wi-Fi TX and RX is 2412-2462MHz, 5150MHz~5350MHz; 5470MHz 5725MHz, 5725MHz 5850MHz. EMC_SZ_FR_24.00 IC Release 2017-03-13 TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District, Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299 Page 4 of 304 Report Number: 68.950.22.0676.01 4 Summary of Test Standards FCC Part 15 Subpart C 10-1-2020 Edition RSS-Gen Issue 5, Amendment 2, February 2021 RSS-247 Issue 2 February 2017 Test Standards PART 15 - RADIO FREQUENCY DEVICES Subpart C - Intentional Radiators General Requirements and Information for the Certification of Radio Apparatus Digital Transmission Systems (DTSS), Frequency Hopping Systems (FHSS) and License-Exempt Local Area Network (LE-LAN) Devices Test Method: FCC KDB 558074 D01 15.247 Meas Guidance v05r02 KDB 789033 D02 General UNII Test Procedures New Rules v02r01 KDB 905462 D02 UNII DFS Compliance Procedures New Rules v02 ANSI C63.10-2013, American National Standard for Testing Unlicensed Wireless Devices EMC_SZ_FR_24.00 IC Release 2017-03-13 TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District, Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299 Page 5 of 304 Report Number: 68.950.22.0676.01 5 Summary of Test Results Test Condition RSS-Gen Clause 8.8 Conducted Emission AC Power Port RSS-247 Clause 6.2 Emission bandwidth RSS-247 Clause 6.2 Maximum Conducted Output Power RSS-247 Clause 6.2 Maximum Power Spectral Density RSS-247 Clause 6.2 RSS-Gen Clause 8.9 Unwanted Emissions RSS-247 Clause 6.2 RSS-Gen Clause 8.9 Band edge compliance RSS-Gen Clause 6.11 Frequencies Stability RSS-247 Clause 6.3 Dynamic Frequency Selection (DFS). RSS-GEN Clause 6.8 Antenna Requirement Test Result Pass Fail N/A See note1 Note 1: The EUT uses an Integrated antenna, which gain is 2dBi for Ant1 and Ant2. It is considered sufficiently to comply with the provisions of this section. EMC_SZ_FR_24.00 IC Release 2017-03-13 TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District, Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299 Page 6 of 304 Report Number: 68.950.22.0676.01 6 General Remarks Remarks This submittal(s) (test report) is intended for FCC ID: 2AIMRMITVMDZ28AA, IC: 25940MITVMDZ28AA complies with the FCC Part 15, Subpart and RSS-247 issue 2 and RSS-Gen issue 5 rules. This report is for the 5GHz Wi-Fi. SUMMARY: All tests according to the regulations cited on page 5 were - Performed - Not Performed The Equipment Under Test - Fulfills the general approval requirements. - Does not fulfill the general approval requirements. TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch. Sample Received Date: July 6, 2022 Testing Start Date: July 6, 2022 Testing End Date: August 5, 2022 TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch. Reviewed by: Prepared by: Tested by: _______________________ John Zhi EMC Project Manager _______________________ Mark Chen EMC Project Engineer _______________________ Carry Cai EMC Test Engineer EMC_SZ_FR_24.00 IC Release 2017-03-13 TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District, Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299 Page 7 of 304 Report Number: 68.950.22.0676.01 7 Test setups 7.1 7.1 Radiated test setups Below 1GHz Above 1GHz 7.2 AC Power Line Conducted Emission test setups 7.3 Conducted RF test setups Measuring receiver EUT EMC_SZ_FR_24.00 IC Release 2017-03-13 TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District, Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299 Page 8 of 304 Report Number: 68.950.22.0676.01 8. Systems test configuration Characteristics TX/RX Operating Band IEEE 802.11 WLAN Mode Supported Channel Bandwidth Description 5150 MHz to 5825 MHz 802.11a: 802.11n20: 802.11n40: 802.11ac20: 802.11ac40: 802.11ac80: 20MHz, 40MHz, 80MHz Support Support Support Support Support Support The system was configured to channel: Test Mode 802.11a, 802.11n20, 802.11ac20 CH36 (5180MHz) CH52 (5260MHz) CH100 (5500MHz) CH149 (5745MHz), Channel (MHz) 5G WI-FI-Band 1 CH40 (5200MHz) 5G WIFI-Band 2 CH56 (5280MHz) 5G WIFI-Band 3 CH116 (5580MHz) 5G WIFI-Band 4 CH157(5785MHz) CH46 (5240MHz) CH64 (5320MHz) CH140 (5700MHz) CH165 (5825MHz) Test Mode 802.11n40, 802.11ac40 Test Mode 802.11ac80 CH38(5190MHz) CH54(5270MHz) CH102(5510MHz) CH151(5755MHz) Channel (MHz) 5G WI-FI-Band 1 CH46 (5230MHz) 5G WIFI-Band 2 CH62(5310MHz) 5G WIFI-Band 3 CH110(5550MHz) CH134(5670MHz) CH 142 (5710MHz) 5G WIFI-Band 4 CH159(5795MHz) Channel (MHz) 5G WI-FI-Band 1 CH42(5210MHz) 5G WI-FI-Band 2 CH58(5290MHz) 5G WIFI-Band 3 CH106(5530MHz) CH138(5690MHz) 5G WIFI-Band 4 CH155(5775MHz) EMC_SZ_FR_24.00 IC Release 2017-03-13 TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District, Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299 Page 9 of 304 Report Number: 68.950.22.0676.01 9 Technical Requirement 9.1 Conducted emission AC power port Test Method 1. The EUT was placed on a table, which is 0.8m above ground plane 2. The power line of the EUT is connected to the AC mains through a Artificial Mains Network (A.M.N.). 3. Maximum procedure was performed to ensure EUT compliance 4. A EMI test receiver is used to test the emissions from both sides of AC line Limit Frequency MHz 0.150-0.500 0.500-5 5-30 QP Limit dBV 66-56* 56 60 AV Limit dBV 56-46* 46 50 Remark: "*" Decreasing linearly with logarithm of the frequency EMC_SZ_FR_24.00 IC Release 2017-03-13 TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District, Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299 Page 10 of 304 Report Number: 68.950.22.0676.01 Product Type M/N Operating Condition Test specification Comment : Xiaomi Box 4K : MDZ-28-AA : Normal working with transmitting : Live : AC 120V/60Hz Level in dB Critical_Freqs Frequency MaxPeak (MHz) (dBµV) 0.162000 54.09 0.453500 0.730000 1.322000 47.42 41.69 40.06 2.230000 4.798000 37.90 36.74 Average (dBµV) ------------- Limit (dBµV) 65.36 56.73 56.00 56.00 56.00 56.00 Margin (dB) 11.27 9.31 14.31 15.94 18.10 19.26 Line L1 L1 L1 L1 L1 L1 Corr. (dB/m) 9.26 9.20 9.20 9.21 9.23 9.30 Final_Result Frequency QuasiPeak Average Limit Margin Line Corr. (MHz) (dBµV) (dBµV) (dBµV) (dB) (dB/m) 0.453500 --- 34.77 46.81 12.04 L1 9.20 0.453500 44.51 --- 56.81 12.30 L1 9.20 Remark: Level=Reading Level + Correction Factor Correction Factor=Cable Loss + LISN Factor (The Reading Level is recorded by software which is not shown in the sheet) EMC_SZ_FR_24.00 IC Release 2017-03-13 TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District, Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299 Page 11 of 304 Report Number: 68.950.22.0676.01 Product Type : Xiaomi Box 4K M/N : MDZ-28-AA Operating Condition : Normal working with transmitting Test specification : Neutral Comment : AC 120V/60Hz Level in dB Critical_Freqs Frequency MaxPeak (MHz) (dBµV) 0.158000 0.458500 0.473500 54.48 48.96 47.53 0.730000 1.302000 39.66 38.98 2.806000 40.45 Average (dBµV) ------------- Limit (dBµV) 65.57 56.80 56.37 56.00 56.00 56.00 Margin (dB) 11.09 7.84 8.85 16.34 17.02 15.55 Line N N N N N N Corr. (dB/m) 9.40 9.39 9.39 9.39 9.41 9.44 Final_Result Frequency QuasiPeak Average Limit Margin Line Corr. (MHz) (dBµV) (dBµV) (dBµV) (dB) (dB/m) 0.458500 0.458500 --46.42 36.85 46.72 9.87 N 9.39 --- 56.72 10.30 N 9.39 0.473500 0.473500 --43.37 33.50 46.45 12.95 N 9.39 --- 56.45 13.08 N 9.39 Remark: Level=Reading Level + Correction Factor Correction Factor=Cable Loss + LISN Factor (The Reading Level is recorded by software which is not shown in the sheet) EMC_SZ_FR_24.00 IC Release 2017-03-13 TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District, Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299 Page 12 of 304 Report Number: 68.950.22.0676.01 9.2 Emission bandwidth The EUT was placed on 0.8m height table, the RF output of EUT was connected to the test receiver by RF cable. The path loss was compensated to the results for each measurement. 1Test Method of 26dB Bandwidth According to C63.10 a) Set RBW = approximately 1% of the emission bandwidth. b) Set the VBW > RBW. c) Detector = Peak. d) Trace mode = max hold. e) Measure the maximum width of the emission that is 26 dB down from the maximum of the emission. Compare this with the RBW setting of the analyzer. Readjust RBW and repeat measurement as needed until the RBW/EBW ratio is approximately 1%. Limit: No limit 2Test Method of 6dB Bandwidth According to C63.10 a) Set RBW = 100KHz b) Set the video bandwidth (VBW) 3 × RBW c) Detector = Peak. d) Trace mode = max hold. e) Sweep = auto couple. f) Allow the trace to stabilize. g) Measure the maximum width of the emission that is constrained by the frequencies associated with the two outermost amplitude points (upper and lower frequencies) that are attenuated by 6 dB relative to the maximum level measured in the fundamental emission. Limit: 500KHz 3Test Method of 99% Bandwidth According to C63.10 a) Set center frequency to the nominal EUT channel center frequency b) Set span = 1.5 times to 5.0 times the OBW. c) Set RBW = 1 % to 5 % of the OBW d) Set VBW 3 · RBW e) Video averaging is not permitted. Where practical, a sample detection and single sweep mode shall be used. Otherwise, peak detection and max hold mode (until the trace stabilizes) shall be used. f) Use the 99 % power bandwidth function of the instrument (if available). g) If the instrument does not have a 99 % power bandwidth function, the trace data points are recovered and directly summed in power units. The recovered amplitude data points, beginning at the lowest frequency, are placed in a running sum until 0.5 % of the total is reached; that frequency is recorded as the lower frequency. The process is repeated until 99.5 % of the total is reached; that frequency is recorded as the upper frequency. The 99% occupied bandwidth is the difference between these two frequencies. Limit: No limit EMC_SZ_FR_24.00 IC Release 2017-03-13 TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District, Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299 Page 13 of 304 Report Number: 68.950.22.0676.01 26dB Bandwidth Test result: TestMode Antenna Channel[MHz] 26db EBW [MHz] FL[MHz] FH[MHz] 11A Ant1 11N20 SISO Ant1 11N40 SISO Ant1 11AC20 SISO Ant1 EMC_SZ_FR_24.00 IC Release 2017-03-13 5180 27.400 5166.440 5193.840 5200 26.440 5186.440 5212.880 5240 24.280 5228.280 5252.560 5260 23.040 5248.320 5271.360 5280 25.520 5268.280 5293.800 5320 24.240 5308.280 5332.520 5500 20.640 5489.600 5510.240 5580 20.560 5569.680 5590.240 5700 20.560 5689.680 5710.240 5720 20.640 5709.600 5730.240 5720_UNII-2C 15.4 5709.600 5725 5720_UNII-3 5.24 5725 5730.240 5745 20.520 5734.720 5755.240 5785 20.440 5774.800 5795.240 5825 20.520 5814.720 5835.240 5180 5200 5240 5260 5280 5320 5500 5580 5700 5720 5720_UNII-2C 5720_UNII-3 5745 5785 5825 5190 5230 26.480 27.400 23.080 25.800 25.880 24.000 21.640 20.560 20.800 20.400 15.12 5.28 20.800 20.400 20.480 67.360 67.440 5167.360 5186.440 5228.600 5247.400 5267.360 5307.400 5489.080 5569.720 5689.680 5709.880 5709.880 5725 5734.680 5774.760 5814.760 5156.240 5196.240 5193.840 5213.840 5251.680 5273.200 5293.240 5331.400 5510.720 5590.280 5710.480 5730.280 5725 5730.280 5755.480 5795.160 5835.240 5223.600 5263.680 5270 67.360 5236.240 5303.600 5310 67.360 5276.320 5343.680 5510 45.920 5485.920 5531.840 5550 45.280 5525.920 5571.200 5670 52.880 5645.840 5698.720 5710 46.000 5685.840 5731.840 5710_UNII-2C 39.16 5685.840 5725 5710_UNII-3 6.84 5725 5731.840 5755 45.120 5730.920 5776.040 5795 45.040 5771.000 5816.040 5180 26.680 5167.160 5193.840 5200 27.040 5187.120 5214.160 5240 24.400 5227.360 5251.760 5260 25.840 5247.360 5273.200 TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District, Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299 Limit[MHz] Verdict --- PASS --- PASS --- PASS --- PASS --- PASS --- PASS --- PASS --- PASS --- PASS --- PASS --- PASS --- PASS --- PASS --- PASS --- PASS --- PASS --- PASS --- PASS --- PASS --- PASS --- PASS --- PASS --- PASS --- PASS --- PASS --- PASS --- PASS --- PASS --- PASS --- PASS --- PASS --- PASS --- PASS --- PASS --- PASS --- PASS --- PASS --- PASS --- PASS --- PASS --- PASS --- PASS --- PASS --- PASS --- PASS --- PASS Page 14 of 304 Report Number: 68.950.22.0676.01 5280 26.120 5267.120 5293.240 --- PASS 5320 25.240 5307.360 5332.600 --- PASS 5500 20.680 5489.760 5510.440 --- PASS 5580 20.520 5569.680 5590.200 --- PASS 5700 21.040 5689.640 5710.680 --- PASS 5700 20.120 5689.880 5710.000 --- PASS 5720 20.880 5709.760 5730.640 --- PASS 5720_UNII-2C 15.24 5709.760 5725 --- PASS 5720_UNII-3 5.64 5725 5730.640 --- PASS 5745 20.760 5734.640 5755.400 --- PASS 5785 20.560 5774.680 5795.240 --- PASS 5825 20.600 5814.600 5835.200 --- PASS 5190 69.360 5154.640 5224.000 --- PASS 5230 69.120 5194.640 5263.760 --- PASS 5270 67.360 5236.320 5303.680 --- PASS 5310 67.360 5276.320 5343.680 --- PASS 5510 51.360 5484.400 5535.760 --- PASS 11AC40 SISO Ant1 5550 5670 47.120 5527.760 5574.880 --- PASS 54.160 5644.400 5698.560 --- PASS 5710 51.360 5684.400 5735.760 --- PASS 5710_UNII-2C 40.6 5684.400 5725 --- PASS 5710_UNII-3 10.76 5725 5735.760 --- PASS 5755 47.120 5732.680 5779.800 --- PASS 5795 44.400 5772.840 5817.240 --- PASS 5210 118.400 5149.520 5267.920 --- PASS 5290 104.800 5235.600 5340.400 --- PASS 5530 81.920 5489.200 5571.120 --- PASS 11AC80 SISO Ant1 5690 82.240 5649.040 5731.280 --- PASS 5690_UNII-2C 75.96 5649.040 5725 --- PASS 5690_UNII-3 6.28 5725 5731.280 --- PASS 5775 82.240 5734.040 5816.280 --- PASS EMC_SZ_FR_24.00 IC Release 2017-03-13 TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District, Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299 Page 15 of 304 Report Number: 68.950.22.0676.01 26dB Bandwidth Test Graphs 11A_Ant1_5180 11A_Ant1_5200 11A_Ant1_5240 EMC_SZ_FR_24.00 IC Release 2017-03-13 TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District, Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299 Page 16 of 304 Report Number: 68.950.22.0676.01 11A_Ant1_5260 11A_Ant1_5280 11A_Ant1_5320 EMC_SZ_FR_24.00 IC Release 2017-03-13 TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District, Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299 Page 17 of 304 Report Number: 68.950.22.0676.01 11A_Ant1_5500 11A_Ant1_5580 11A_Ant1_5700 EMC_SZ_FR_24.00 IC Release 2017-03-13 TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District, Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299 Page 18 of 304 Report Number: 68.950.22.0676.01 11A_Ant1_5720 11A_Ant1_5745 11A_Ant1_5785 EMC_SZ_FR_24.00 IC Release 2017-03-13 TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District, Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299 Page 19 of 304 Report Number: 68.950.22.0676.01 11A_Ant1_5825 11N20_Ant1_5180 11N20_Ant1_5200 EMC_SZ_FR_24.00 IC Release 2017-03-13 TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District, Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299 Page 20 of 304 Report Number: 68.950.22.0676.01 11N20_Ant1_5240 11N20_Ant1_5260 11N20_Ant1_5280 EMC_SZ_FR_24.00 IC Release 2017-03-13 TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District, Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299 Page 21 of 304 Report Number: 68.950.22.0676.01 11N20_Ant1_5320 11N20_Ant1_5500 11N20_Ant1_5580 EMC_SZ_FR_24.00 IC Release 2017-03-13 TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District, Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299 Page 22 of 304 Report Number: 68.950.22.0676.01 11N20_Ant1_5700 11N20_Ant1_5720 11N20_Ant1_5745 EMC_SZ_FR_24.00 IC Release 2017-03-13 TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District, Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299 Page 23 of 304 Report Number: 68.950.22.0676.01 11N20_Ant1_5785 11N20_Ant1_5825 11N40_Ant1_5190 EMC_SZ_FR_24.00 IC Release 2017-03-13 TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District, Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299 Page 24 of 304 Report Number: 68.950.22.0676.01 11N40_Ant1_5230 11N40_Ant1_5270 11N40_Ant1_5310 EMC_SZ_FR_24.00 IC Release 2017-03-13 TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District, Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299 Page 25 of 304 Report Number: 68.950.22.0676.01 11N40_Ant1_5510 11N40_Ant1_5550 11N40_Ant1_5670 EMC_SZ_FR_24.00 IC Release 2017-03-13 TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District, Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299 Page 26 of 304 Report Number: 68.950.22.0676.01 11N40_Ant1_5710 11N40_Ant1_5755 11N40_Ant1_5795 EMC_SZ_FR_24.00 IC Release 2017-03-13 TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District, Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299 Page 27 of 304 Report Number: 68.950.22.0676.01 11AC20_Ant1_5180 11AC20_Ant1_5200 11AC20_Ant1_5240 EMC_SZ_FR_24.00 IC Release 2017-03-13 TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District, Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299 Page 28 of 304 Report Number: 68.950.22.0676.01 11AC20_Ant1_5260 11AC20_Ant1_5280 11AC20_Ant1_5320 EMC_SZ_FR_24.00 IC Release 2017-03-13 TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District, Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299 Page 29 of 304 Report Number: 68.950.22.0676.01 11AC20_Ant1_5500 11AC20_Ant1_5580 11AC20_Ant1_5700 EMC_SZ_FR_24.00 IC Release 2017-03-13 TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District, Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299 Page 30 of 304 Report Number: 68.950.22.0676.01 11AC20_Ant1_5720 11AC20_Ant1_5745 11AC20_Ant1_5785 EMC_SZ_FR_24.00 IC Release 2017-03-13 TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District, Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299 Page 31 of 304 Report Number: 68.950.22.0676.01 11AC20_Ant1_5825 11AC40_Ant1_5190 11AC40_Ant1_5230 EMC_SZ_FR_24.00 IC Release 2017-03-13 TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District, Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299 Page 32 of 304 Report Number: 68.950.22.0676.01 11AC40_Ant1_5270 11AC40_Ant1_5310 11AC40_Ant1_5510 EMC_SZ_FR_24.00 IC Release 2017-03-13 TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District, Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299 Page 33 of 304 Report Number: 68.950.22.0676.01 11AC40_Ant1_5550 11AC40_Ant1_5670 11AC40_Ant1_5710 EMC_SZ_FR_24.00 IC Release 2017-03-13 TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District, Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299 Page 34 of 304
Related FCC IDs:
- 2AIMRMITVMDZ28AA - Beijing Xiaomi Electronics Co.,Ltd Xiaomi Box 4K which supports Bluetooth and Wi-Fi [MITVMDZ28AA] PDF-XChange Editor 6.0.319 PDF-XChange Core API SDK (6.0.319)