Technical Guide
Maestro B0972 Winterizing Kit 8.0”
Maestro 02234 Pro Inverter 12 Heat Pump RVUX (208/230V)
Maestro B0973 Condensate Pan Heating Cable (230V)
User Guide for MAESTRO models including: 02216, 01925, 02283, 02234, Pro Series, Pro Series Industry Leading Inverter Compressor, Industry Leading Inverter Compressor, Leading Inverter Compressor, Inverter Compressor, Compressor
Not Your Device? Search For Manuals or Datasheets below:
File Info : application/pdf, 55 Pages, 12.99MB
Document DEVICE REPORT02216 Technical GuideTECHNICAL GUIDE BEAUTIFUL OUTSIDE COMFORTABLE INSIDE 1 TABLE OF CONTENTS Models 3 Maestro Accessory Submittals 36 Louvred Grille Accessory - Rectangle 37 Maestro Pro Inverter 12 HP (115V & 230V) Louvred Grille Accessory - Square 38 Features and Functions 4 Side wall Adapter Submittal 39 Performance Data 5 Window Sill Adapter Submittal 40 Electrical, Compressor and Airflow 6 PTAC Retrofit Kit Submittal 41 Physical Data 7 Sub Base Submittal 42 Application and Installation 8 Recessed Panel Kit and Installation Housing 43 Installation 9 Parts 10 Sound Pressure & Sound Transmission Class 44 Wiring Diagrams 11 Certifications Maestro Smart 9 HP (115V) California Energy Commission 45 Features and Functions 14 Maestro Pro Intertek ETL Certificate 46 Performance Data 15 Meastro Smart Intertek ETL Certificate 48 Electrical, Compressor and Airflow 16 Limited Warranty USA and Canada 49 Physical Data 17 Application and Installation 18 Installation 19 Parts 20 Wiring Diagram 21 Accessories 22 Controls Offering - Thermostats 25 2 MODELS Maestro Smart 9 HP (115V): Model #02216 The Smart Series is the year-round comfort solution, providing heating and cooling capacities up to 9,200 BTU/h. The unit is equipped with a multifiltration system, and dehumidification and sleep modes for whisper-quiet operation in residential and commercial applications. Maestro Pro Inverter 12 HP (115V): Model #01925 The Pro Series, with its industry leading inverter compressor technology and variable-speed fan motor, provides unparalleled comfort with no swings in temperature when heating or cooling your home or business. Maestro Pro Inverter 12 HP RVU (208/230V): Model #02283 The Pro Series, with its industry leading inverter compressor technology and variable-speed fan motor, provides unparalleled comfort with no swings in temperature when heating or cooling your home or business. Maestro Pro Inverter 12 HP RVUX (208/230V): Model #02234 The Pro Series, with its industry leading inverter compressor technology and variable-speed fan motor, provides unparalleled comfort with no swings in temperature when heating or cooling your home or business. The unit has a 2.0 kW back up electric heater, which can be field programmed to turn on based on low ambient temperatures. 3 FEATURES AND FUNCTIONS: MAESTRO PRO INVERTER 12 HP MODEL #01925 Industry leading inverter compressor technology provides unparalleled comfort in heating and cooling for both residential or commercial applications Cooling Capacity (BTU/h): Up to 11,600 Heating Capacity (BTU/h): Up to 10,600 Installation Versatility: Low or high wall Easy installation: Can be installed from inside the space in just a few minutes Rotating Flap: Provides total air diffusion for consistent temperature throughout the space. Backlite Display: On-board touch control User Control Options: · Multifunction remote (Standard) · Wired wall mounted thermostat (Optional) · Wireless wall mounted thermostat (Optional) 24 hour Timer Sound Transmission: Best in Class STC and OITC Dehumidification Mode Controls humidity during mild ambient conditions for increased comfort Sleep Mode Gradually increases the temperature setpoint ensuring whisper quiet operation, greater comfort and energy savings while you sleep. Remote Control "Fully Digital" remote control allows functions such as dehumidification, silent mode, sleep mode and ventilation mode. Variable Speed Fan (ECM) The fan motor has a variable frequency drive technology installed to control motor speed and torque (V PRO). Designed to eliminate swings in temperature resulting in reduced energy consumption while providing quiet operation in all modes. Variable speed motor maintains a consistent temperature throughout the conditioned space. Economy Mode Allows for energy saving by automatically optimizing the unit's performance Inverter Compressor Innovative compressor technology that is versatile and efficient with a wide range of frequencies available and with electronic expansion valve (EXV). Heat Pump Our reverse cycle heat pumps offer both heating and cooling to provide occupants with year-round comfort. It can also be used as backup heat during shoulder seasons. Silent Mode Maestro Pro is designed so the inverter compressor and variable speed fan motor operate for maximum acoustical comfort down to 32 dB(A) (sound pressure). All enclosed in a sleek Italian designed cabinet by Matteo Thun and lined with state-of-the-art sound reducing material. Allows the user to set the system to minimum sound level. 4 Auto Mode Adjusts comfort settings based on ambient conditions. Pro Power The use of inverter technology provides a capacity boost up to 11,600 BTU/h Wi-Fi Ready Industry leading Wi-Fi technology with all the security of the cloud Pure System 2 A multi-filtration system that combines two state of the art filtration technologies: - An Electrostatic Filter designed to eliminate small particles such as smoke, dust, pollen and pet dander to provide relief to people with allergies. - An Active Carbon Filter which eliminates unpleasant odors keeping the indoor air quality fresh and clean. PERFORMANCE DATA: MAESTRO PRO INVERTER 12 HP Model Cooling Heating 47°F Heating 17°F Heating 5°F Sound 01925 02234 02283 Capacity Range (Min - Max) Capacity (Rated) Input Power (Rated) Input Power (Max) Operating Range (Outdoor) Btu/h Btu/h W W °F/ °C 6,600 - 11,600 6,100 - 10,700 8,300 7,600 800 710 1,400 1,200 64°F/18°C-109°F/43°C 64°F/18°C-109°F/43°C Combined Energy Efficiency Ratio CEER 9.7 Moisture Removal Pts/h 2.3 Sensible Heat Factor % 0.7 Capacity Range (Min - Max) Btu/h 6,200 - 10,600 Capacity (Rated) Btu/h 8,450 Input Power (Rated) W 825 Input Power (Max) W 1,400 Energy Efficiency COP 3.0 Operating Range (Outdoor) °F 5°F/-15°C-75°F/24°C Defrost Method Reverse cycle Capacity Range (Min - Max) Btu/h 2,900 - 4,900 Input Power (Min-Max) W 390 - 930 Energy Efficiency (Min-Max) COP 2.15 - 1.54 Capacity Range (Min - Max) Btu/h 2,200 - 4,000 Input Power (Min - Max) W 340 - 780 Energy Efficiency (Min - Max) COP 1.90 - 1.50 STC (Sound Transmission Class) 36 OITC (Outdoor/Indoor Transmission Class) 25 Sound Level dB(A) min-max 32 - 43 Outdoor dB(A) up to 53 13.0 2.1 0.7 5,800 - 10,200 8,050 800 1,200 2.9 5°F/-15°C-75°F/24°C Reverse cycle 2,700 - 4,700 370 - 890 2.13 - 1.53 2,100 - 3,800 320 - 730 1.53 - 1.92 36 25 32 - 43 up to 53 6,600 - 11,600 8,300 800 1,400 64°F/18°C109°F/43°C 9.7 2.3 0.7 6,200 - 10,600 8,450 825 1,400 3.0 5°F/-15°C-75°F/24°C Reverse cycle 2,900 - 4,900 390 - 930 2.15 - 1.54 2,200 - 4,000 340 - 780 1.90 - 1.50 36 25 32 - 42 up to 53 · Test condition: Data refers to conditions and parameters as required by DOE requirements governing this product type. HEATING MODE: Outdoor Ambient Temperature DB 47°F/8.3°C WB 43°F/6°C; Indoor Ambient DB 70°F/21°C - WB 60°F/15.6°C COOLING MODE: Outdoor Ambient Temperature DB 95°F/35°C WB 75°F/24°C; Indoor Ambient DB 80°F/26.7°C - WB 67°F/19.4°C · Maximum capacity achieved with Power Pro Boost inverter technology. To achieve full capacity and efficiency 8" diameter openings are recommended. Alternately, 6.5" diameter openings can be used however there is a corresponding loss to capacity and efficiency which can vary based on the specific application. · CEER is calculated according to the AHAM RAC-1-2020 standard. The Combined Energy Efficiency Ratio (CEER) is a standard that measures the combined efficiency of the unit when it is in standby and when it's actually cooling a space · Test conditions for sound ratings are conducted as per DOA rating conditions, conducted in a sound chamber performed at a distance of 6.5 feet (2 meters). Minimum sound pressure values are rated in ventilation mode only. · STC and OITC calculated by an independent 3rd party in accordance with ASHRAE standards. 5 ELECTRICAL, COMPRESSOR & AIRFLOW: MAESTRO PRO INVERTER 12 HP Model Compressor Electrical Airflow Type Brand RLA Refrigerant Refrigerant Factory Charge Oil Voltage Volt Range Hz/Phase Power Supply Power Factor Cooling (Rated) Heating (Rated) Outdoor EC Fan Motor Indoor EC Fan Motor MCA MOCP Input Power (standby) Input Power (off mode) Indoor Outdoor A ASHRAE # lbs - oz Type Oz. AC Volts A A F.L.A. HP F.L.A. A A W W Type CFM Speeds dB(A) Type CFM Speeds dB(A) Vent 01925 Rotary Inverter GMCC 4.9 R-410A 1 - 5 VG74 9.5 115 98 - 127 60-1 LCDI power cord 0.85 9.7 9.9 1.93 0.17 .33 10.9 15 3 .5 ECM Up to 245 3 Up to 41 ECM Up to 350 6 51 6.4" - 8" 02234 Rotary Inverter GMCC 4.9 R-410A 1 - 5 VG74 9.5 208 - 230 187 - 253 60-1 LCDI power cord 0.85 3.5 3.8 0.97 0.17 .14 12.5 15 3 .5 ECM Up to 290 3 Up to 41 ECM Up to 350 6 51 6.4" - 8" 02283 Rotary Inverter GMCC 4.9 R-410A 1 - 5 VG74 9.5 208 - 230 187 - 253 60-1 LCDI power cord 0.85 4.8 5 0.97 0.17 .14 12.5 15 3 .5 ECM Up to 245 3 Up to 41 ECM Up to 350 6 51 6.4" - 8" 6 PHYSICAL DATA: MAESTRO PRO INVERTER 12 HP Model Controls Modes Condensate Removal External Vents Physical Data Certification Warranty Origin Basic Functionality WiFi Third Party Controller Compatibility BACnet/Modbus Compatible ADA Compliant Dry Contact Restricted Options Power Outage Restart Operation Restricted Modes Timers Cooling Heating (Heat Pump) Drain Pipe Size In. Vent Pipes In. Grilles Unit W/H/D Shipping W/H/D Net Weight Lbs. Shipping Weight Lbs. Cabinet Color Finish Material Safety Energy Efficiency 1 Year (Limited) 2 Years (Limited) 7 Years (Limited) Country of Origin 01925 02234 02283 Optional Backlit, Dimable, On-board Touch Controller Optional Optional Optional for Standard and Smart Thermostats Yes Yes Yes Yes Yes Yes Yes Yes Yes Key Pad Lock Key Pad Lock Key Pad Lock Returns to Last Setting Cooling, Heating, Dehumidify, Fan Only, Auto 24 Hour Heat Only, Cool Only, Temperature Limiting 24 Hour 24 Hour Built-in condensate slinger and disposal via gravity drain Gravity Drain Gravity Drain Gravity Drain 0.8" 0.8" 0.8" 6.4" - 8" 6.4" - 8" 6.4" - 8" Standard and Custom Options Available 35.5" x 20.4" x 8.5" 35.5" x 20.4" x 8.5" 35.5" x 20.4" x 8.5" 38.6" x 24" x 13" 38.6" x 24" x 13" 38.6" x 24" x 13" 86 86 86 93 93 93 RAL 9003 RAL 9003 RAL 9003 Specular high gloss Specular high gloss Specular high gloss Plastic Plastic Plastic UL 60335-2-40 UL 60335-2-40 UL 60335-2-40 AHAM RAC-1-2020 AHAM RAC-1-2020 AHAM RAC-1-2020 Unit Replacement Unit Replacement Unit Replacement Parts Parts Parts Compressor Compressor Compressor Italy Italy Italy 7 APPLICATION & INSTALLATION: MAESTRO PRO INVERTER 12 HP DIMENSIONS: A 35.6" B 8.5" C 20.5" CLEARANCES: 2.4" (min 60mm) 4" (min 80mm) Unit Dimensions A B C Weight 35.6" 8.5" 20.5" 86 lbs 2.4" (min 60mm) 4" (min 80mm) 8 MAESTRO PRO INVERTER 12 HP: INSTALLATION TEMPLATE 9 7 4 3 2 1 PARTS: MAESTRO PRO INVERTER 12 HP 10 9 6 44 31 14 15 38 16 37 37 13 42 12 17 38 52 51 11 41 5 43 30 18 12 49 54 53 40 33 19 21 22 48 35 28 29 27 25 23 24 24 24 46 26 47 36 36 32 39 34 50 20 45 Via Industriale 1/3 Cellatica (BS.) MAESTRO PRO HP Agg. Ottobre 2019 - RIF: 299.00 1. Step Motor - Part #277816A 20. Rear Panel - Part #595230A 38. Duct Sleeves - Part #242440A 2. Flap - Part #282642B 21. Four Way VAL ASSY - Part #595357A 39. Pro Remote Control - Part #592585C 3. Aesthetic Group - Part #595366A 22. Expansion Valve Coil - Part #277831A 40. Slinger - Part #595221B 4. Left Mask - Part #282730A 23. Compressor - Part #277917A 41. Protection Grid - Part #214691B 5. Right Mask - Part #282733A 24. Vibration Dumping for Compressor - Part #281502A 42. Fan Elastic Mount - Part #279391A 6. Main ODU Inverter Board 115V - Part # 277912C 25. Float Assembly - Part #595177A 42. Teflon Bearing - Part #279392A 7. Upper Panel - Part #282732A 26. Lower Drain Pan - Part #282712A 43. Condensing Cover Group - Part #595234B 9. IPM Board - Part #277900A 27. Pump - Part #277819B 44. Left Panel Group - Part #595233A 10. ODU Board Cover - Part #282786A 28. Thermal Actuator - Part #277865A 45. Right Panel Group - Part #595355A 11. Tangential Fan - Part #282740A 29. Actuator Plug - Part #282715A 46. Main Drain Plug - Part #K190000500A 12. Pro mounting Bracket - Part #214268A 30. Condenser fan assembly - Part #595307A 47. Secondary Drain Plug - Part #242473A 13. Room Temperature Sensor - Part #255436A 31. Front Cover Group - Part #595354A 48. Expansion valve assembly - Part #595358A 14. Carbon Filter - Part #K070011500A 32. Spring and Chain kit - Part #599922A 49. Relais Finder 120VAC/16A 250V - Part #277885A 15. Particulate Filter - Part #K070011600A 33. Four Way Coil Assy - Part #595257A 50. Bipolar Switch - Part #276986A 16. Mesh Filter - Part #282739A 34. LCDI Power Cable (Tower 30380) - Part #K160010400A 51. ODU Temperature Sensors - Part #255435A 17. Evaporator Heat Exchanger Group - Part #595269A 35. Condenser Heat Exchanger Assy - Part #595264A 52. IDU Heat-Exchang.Temperature - Part #255437A 18. Evaporator Motor - Part #277914A 36. Exterior grille set of 2 - Part #594825A 53. IDU Board Front Cover 115v - Part #282789A 19. Main Board HP ASK89 - Part #277901C 37. Inner rings set of 2 - Part #282465A 54. Display Electric Board - Part #277890A 10 WIRING DIAGRAM: MAESTRO PRO INVERTER 12 HP (115V) MODEL #1925 11 WIRING DIAGRAM: MAESTRO PRO INVERTER 12 HP WITH 2KW ELECTRIC HEAT (230V) MODEL #2234 12 WIRING DIAGRAM: MAESTRO PRO INVERTER 12 HP (230V) MODEL #2283 13 FEATURES AND FUNCTIONS: MAESTRO SMART 9 HP MODEL #02216 Designed to provide quiet and efficient comfort cooling and heating for both residential or commercial spaces. Cooling Capacity (BTU/h): 9,200 Heating Capacity (BTU/h): 8,500 Comfort Model: Heat Pump Refrigerant: R410A Installation Versatility: High or low wall Easy installation: Can be installed from inside the space in just a few minutes Rotating Flap: Provides total air diffusion for consistent temperature throughout the space User Control Options: · Multifunction remote (Standard) · Wireless Wall Mounted Thermostat (Optional) 24 hour Timer Sound Transmission: Best in Class STC and OITC Dehumidification Mode Reduces airflow to increase the amount of moisture removed from the space. Fan Mode Adjustable 3 speed fan with fan only mode to optimize air circulation Auto Mode Adjusts setpoint based on ambient temperature Sleep Mode Gradually increases the temperature setpoint ensuring whisper quiet operation, greater comfort and energy savings while you sleep. Industry Leading Italian Design: Maestro Smart is the first AC or HP that does not require an outdoor unit! Only two louvered penetrations can be seen on the exterior of the building or home. Heat Pump Our reverse cycle heat pumps offer both heating and cooling to provide occupants with year-round comfort. It can also be used as backup heat during shoulder seasons. Pure System 2 A multi-filtration system that combines two state of the art filtration technologies: - An Electrostatic Filter designed to eliminate small particles such as smoke, dust, pollen and pet dander to provide relief to people with allergies. - An Active Carbon Filter which eliminates unpleasant odors keeping the indoor air quality fresh and clean. Comfort Cooling Cooling capacity can reach up to 9,200 BTU/h providing occupants with unparalleled temperature and humidity control of their indoor environment. Wi-Fi Ready Industry leading Wi-Fi technology with all the security of the cloud 14 Model Cooling Heating 47°F Heating 17°F Heating 5°F Sound PERFORMANCE DATA: MAESTRO SMART 9 HP Capacity (Max) Btu/h Input Power (Rated) W Operating Range (Outdoor) °F/ °C Combined Energy Efficiency Ratio CEER Moisture Removal Pts/h Sensible Heat Factor % Capacity (Rated) Btu/h Input Power (Rated) W Input Power (Max) W Energy Efficiency COP Operating Range (Outdoor) °F/ °C Defrost Method Rated Capacity Btu/h Input Power (Rated) W Energy Efficiency (Rated) COP Rated Capacity Btu/h Input Power (Rated) W Energy Efficiency COP STC (Sound Transmission Class) OITC (Outdoor/Indoor Transmission Class) Sound Level dB(A) min-max Outdoor dB(A) 02216 9,200 930 64°F/18°C-109°F/43°C 9.3 2.5 .7 8,500 850 1,000 2.9 5°F/-15°C-75°F/24°C Reverse cycle 3,400 600 1.66 2,700 570 1.39 36 25 33-42 Up to 56 · CEER is calculated according to the AHAM RAC-1-2020 standard. · The Combined Energy Efficiency Ratio (CEER) is a standard that measures the combined efficiency of the unit when in standby and cooling modes · The sound pressure level was measured in a sound testing at a 6.5 ft distance from the front of the unit meter of height. Min means internal noise fan only at minimum speed. · STC and OITC (Sound Transmission) calculated by an independent 3rd party as per ASHRAE standards · Data plate amps listed as 12amps is based on a power factor of .86 using 1150 watts at 115vac MOCP is 15 amp breaker 15 Model Compressor Electrical Airflow ELECTRICAL, COMPRESSOR & AIRFLOW: MAESTRO SMART 9 HP Type Brand RLA LRA Refrigerant Refrigerant Factory Charge Oil Voltage Volt Range Hz/Phase Power Supply Power Factor Cooling (Rated) Heating (Rated) Outdoor EC Fan Motor Indoor EC Fan Motor MCA MOCP Input Power (standby) Input Power (off mode) Indoor Outdoor 02216 A A ASHRAE # lbs - oz Type Oz. AC Volts/Phase/Hertz Volts A A F.L.A. HP F.L.A. A A W W Type CFM Speeds dB(A) Type CFM Speeds dB(A) Vent Rotary GMCC 6.6 38.9 R-410A 1 - 7 VG74 10.1 115 109-127 60-1 LCDI power cord .91 8.3 8.15 .65 .06 .44 11 15 .5 .5 PSC Up to 215 3 Up to 40 ECM - Variable 265 1 Up to 54 6.4" - 8" 16 Model Controls Modes Condensate Removal External Vents Physical Data Certification Warranty Origin PHYSICAL DATA: MAESTRO SMART 9 HP Basic Functionality WiFi Third Party Controller Compatibility BACnet/Modbus Compatible ADA Compliant Dry Contact Restricted Options Power Outage Restart Operation Restricted Modes Timers Cooling Heating (Heat Pump) Drain Pipe Size In. Vent Pipes In. Grilles Unit W/H/D Shipping W/H/D Net Weight Lbs. Shipping Weight Lbs. Cabinet Color Finish Material Safety Energy Efficiency 1 Year (Limited) 2 Years (Limited) 7 Years (Limited) Country of Origin 02216 Dimable Optional Optional for Standard and Smart Thermostats Yes Yes Yes Key Pad Lock Returns to previous setting Cooling, Heating, Dehumidify, Fan Only, Auto Heat Only, Cool Only, Temperature Limiting 24 Hour Built-in condensate slinger and disposal via gravity drain Gravity Drain 0.8" 6.4" - 8" Standard and Custom Options Available 35.5" x 20.25" x 9" 38.5" x 24" x 14" 88 97 RAL 9003 Specular high gloss Plastic UL 60335-2-40 AHAM RAC-1-2020 Unit Replacement Parts Compressor Italy 17 DIMENSIONS: APPLICATION & INSTALLATION: MAESTRO SMART 9 HP A 35.5" B 9.1" C 20.3" CLEARANCES: Unit Dimensions A B C Weight 35.5" 9.1" 20.3" 88.2 lbs 18 MAESTRO SMART 9 HP: INSTALLATION TEMPLATE 7.7" 1.2" 19 PARTS: MAESTRO SMART 9 HP 61 8 23 22 15 5 4 14 74 13 12 9 7 25 26 29 21 20 18 72 30 16 44 28 27 64 13 34 31 71 35 37 19 38 69 42 69 17 67 50 65 65 36 64 63 39 33 45 66 66 40 62 10 2 1 82 73 3 51 47 49 48 81 54 52 60 53 59 58 75 90 70 78 78 78 55 43 68 Via Industriale 1-3 Cellatica (BS) UNICO SMART 12 HP 60HZ UL Agg. Luglio 2018 - RIF: 335.00 1. Lower Cover - Part #282457A 3. Body - Part #595212B 4. Lever Cover - Part #282446A 5. Step Motor - Part #276856A 7. Capacitor 50MF - Part #277877A 8. Electronic Cover - Part #282880A 9. Electronic Board - Part #277866B 10. Capacitor 3,5MF - Part #277881A 12. Electronic Display - Part #276875A 13. Room Temp. Sensor - Part #255942A 14. Lever - Part #282447A 14. Air Sweep Lever - Part #282448A 14. Lower Motor Lever - Part #282449A 14. Lower Air Sweep Lever - Part #282459A 14. Motor Lever - Part #282460A 15. Flap - Part #282443A 16. Upper Screw Cover - Part #282440A 17. Upper Drain Pan - Part #282451C 18. Protection Grid Narrow Pitch - Part #213258A 19. Drain Pan Mount - Part #282453C 20. Male Pin - Part #281871A72 21. Front Cover - Part #282438A 22. Suction Grid - Part #282470A 23. Suction Grid Pin - Part #282471A 25. Carbon Filter - Part #K070011500A 26. Filter Assembly - Part #594888A 27. Upper Grid - Part #282456A 28. Particulate Filter - Part #K0700116A 29. SX Filter Saddle - Part #282454A 30. DX Filter Saddle - Part #282455A 31. Probe Support - Part #K070003000A 33. Rear Panel Assy - Panel #594788A 34. Connection 1 Pipe - Part #254587A 34. Connection 2 Pipe - Part #254588A 34. Front Evaporator Heat Exchanger - Part #256536B 34. Condenser Coil - Part #256537B 35. Inlet Pipes Group - Part #254585A 36. Outlet Pipes Group - Part #254586A 37. Fan Bearing Group - Part #L020006800A 38. Tangential Fan - Part #282452A 39. Indoor AC Motor - Part #277880A 40. Spring and Chain hardware - Part #599922A 42. Tube Assy - Part #594943A 43. Rear Panel Assy - Part #595188A 44. Slinger - Part #594765A 45. Compressor - Part #277878A 47. Spring-Tube Assy - Part #594886A 48. Condenser Heat Exchanger Group - Part #594772B 49. Fan Motor 115V 50-60HZ Assy - Part #595190A 50. Four Way Val Assy - Part #595265B 51. Capillary Assy - Part #594767B 52. Pump - Part #277870B 53. Pump Mount - Part #282467A 54. Float Switch Assembly - Part #575984A 55. Right Panel Assy - Part #594777A 58. Draining Cup - Part #242473A 59. Thermal Actuator - Part #277865A 59. Obturator - Part #282120A 59. Obturator Cover - Part #282208B 60. Front Panel Assy - Part #594779B 61. Left Panel Assy - Part #594778C 62. Smart Bracket - Part #213264A 63. Smart Remote control (F) - Part #277820A 63. Smart Remote control (C) - Part #276292B 63. Smart Remote control (black) - Part #592587B 64. Inner Ring - Part #282465A 65. Duct sleeve - Part #242440A 66. Exterior Grille - Part #594825A 67. External Temperature Probe - Part #276878A 68. Compressor Cable - Part #255428A 69. Cable Bushing - Part #242436A 70. Compressor Blanket - Part #K090002700A 71. IDU Heat-Heat Exchanger Temp. Sensor - Part #276879A 72. Evaporator Fan Scroll - Part #282450A 73. LCDI Power Cable (Tower 30380) - Part #K160010400A 75. Draining Discharge Cap - Part #K190000500A 78. Compressor Vibration Dampeners - Part #242472A 81. Pump Cover - Part #282469A 82. Electrical Box Insulator Assy - Part #595486A 90. Basement Assy - Part #595211A 20 WIRING DIAGRAM: MAESTRO SMART 9 HP (115V) MODEL #2216 21 Accessory Name Wi-Fi Kit - Maestro Series ACCESSORIES Part Number Description B1018* Designed to provide both Wi-Fi and Bluetooth accessibility. Also provides access to troubleshooting tools found on the main control board. Recessed Panel B0776 Designed to completely hide a Maestro Pro inside a wall. Must be used with installation kit B0775 Recessed Panel Installation Kit B0775 Installation Kit for 8" Opening B0565* Louvered Grille (6.4") B0564* Condensate Pan Heating Cable (115V) B0919* Condensate Pan Heating Cable (230V) B0973 *Use with either Maestro Smart or Pro Required when using recessed panel kit B0776. Often ordered in advance of the Pro unit and B0776 kit Designed for use in new construction applications. This kit includes the wall mount template, mounting bracket, duct sleeves,inside rings and external grilles. Designed for use in new construction applications. Includes the wall mount template, mounting bracket, duct sleeves, inside rings and external grilles Required when the application will experience outdoor temperatures below 32°F (0°C). The cable prevents defrost condensation from freezing in the pan. NOTE: Does not prevent drain line from freezing Required when the application will experience outdoor temperatures below 32°F (0°C). The cable prevents defrost condensation from freezing in the pan. NOTE: Does not prevent drain line from freezing 22 Accessory Name ACCESSORIES Part Number Description Maestro Rain Guard Kit B0753* Contains 2 rain guards Sidewall Adapter B0976 (Right Handed) 8.0" Round B0977 (Left Handed) 8.0" Round B0978 (Right Handed) Rectangular B0979 (Left Handed) Rectangular PTAC Retrofit Kit *Use with either Maestro Smart or Pro B0963 The plenum is designed to fit inside an existing PTAC sleeve which is left in place after the PTAC is removed. NOTE: If the PTAC is larger than 35" (89 cm) wall repair will be required. 23 Accessory Name ACCESSORIES Part Number Description Wired Thermostat B/W Wi-Fi B1022* Wired mini thermostat Wi-Fi ready NOTE: Requires B1021 + B1028 Wired Thermostat Color Wi-Fi B1023* Wired color touch screen thermostat Wi-Fi ready NOTE: Requires B1021 + B1028 Wired Thermostat B/W B1027* Base Module for use with BXXXXX H D Y1 Y2 W1/E W2 G O B Wireless Thermostat BACNET thermostat B00001 B0981* Wired programmable thermostat Wi-Fi ready NOTE: Requires B1021 +B1028 Battery-powered wireless thermostat desired temperature, fan speed, supply air deflector function NOTE: Requires B1021 +B1028 BACnet Communicating Thermostat for Single and Multi-Stage Heat Pump Operation NOTE: Requires B1021 +B1028 Rectangular Louvered Grill B1026* This aluminum grill can be ordered with or without a bug screen and for either 8"or 6.4" applications and it's paintable Square Louvered Grill B1025* This aluminum grill can be ordered with or without a bug screen and for either 8"or 6.4" applications and it's paintable Winterizing Kit (8.0") *Use with either Maestro Smart or Pro 24 B0972 Galvenized Metal Cap - 2 per kit PROGRAMS CONTROLS OFFERING THERMOSTATS MODEL B1022 · 7-day, 5+1+1 day or 1-day programmable with up to 4 time periods per day · Geofencing · Smart recovery auto-adjusts Morning start time to meet setpoint by programmed start time · Vacation mode · Independently adjustable staging deadbands for all stages of heating and cooling (1° - 10° F) · Independently adjustable staging timers for all stages of heating and cooling (1 - 60mins) · Adjustable staging turnoffs, i.e. deenergize 2nd stage at deadband or keep active until setpoint · Setpoint limiting · Keypad lock · Secure API (http or https) · Control to or average a remote sensor - Baby's room or game room, etc. · Outdoor sensor ready with Hi/Low readouts for the day · Dry contact input for twist timers, etc. or . . . · Condensate overflow warning systems lockout compressor with display message · FDD (Equipment Fault Protection) notification · Initiate Vacation Mode · Title 24 compliant · Energy Star certified SMART WI-FI RESIDENTIAL 7-DAY PROGRAMMABLE THERMOSTAT UP TO 4 TIME PERIODS PER DAY UP TO 2 HEAT / 2 COOL UNIVERSAL 3.25 3.25 COMPATIBLE ACCESSORIES Source 1 Compatible Accessory List CTSWFTS LXMINIPLATE-SM LXMINIPLATE-MD LXMINIPLATE-LG Wi-Fi Mini Sensor Small Wall Plate (4.62 W x 4.81 H) Medium Wall Plate (7.12 W x 4.37 H) Large Wall Plate (6.25 W x 6.17 H) ADDWIRE Add-A-Wire makes 4 wires work like 5 STAGING SENSORS SECURITY ALERTS CERTS www.olimpiasplendidusa.com B1022 07/21 25 PRODUCT SPECIFICATIONS Conventional (2H/2C) or Heat Pump (2H/2C) Electric Rating: Output Rating: Control Range: 20-28VAC, 5 VA Max Y1, Y2, G 0.8A, all others 0.4A 3A total max on all outputs 35° - 99° F (2° - 36° C) Control Accuracy: +/- 2° F (+/- 1° C) Remote Sensor: Inputs: Outputs: Wireless Wi-Fi only Dry contact: FDD alerts, condensate alarms, twist timers, etc. Y1, Y2, G, W1/0/B, W2 Connectivity: optional 2.4 GHz b/g/n wifi module MODEL B1022 COMPETITIVE CROSS-REFERENCE Honeywell Emerson Braeburn PRO1 TH6220WF 1F86U-42WF TH6320WF 7300 T701i TERMINAL DESIGNATIONS Terminal Designations R 24 VAC Return G Fan Relay W1/O/B 1st Stage Heat Circuit or Reversing Valve C Dry Contact 24 VAC Return Dry Contact Connections W2 2nd Stage Heat Circuit* Y1 1st Stage Compressor (Cool or Heat) Y2 2nd Stage Compressor (Cool or Heat) www.olimpiasplendidusa.com 2 26 B1022 07/21 USA s Description PROGRAMS TSTA·T7,-dPaRy,O5+G1+R1Md,a7y-oDrA1Y-d,a2yHp/r1oCgrammable with up to 4 time periods per day · Geofencing · Vacation mode STAGING · Dual Fuel compatible with ultra-low balance point · Independently adjustable staging deadbands for all stages of heating and cooling (1° - 10° F) · Independently adjustable staging timers for all stages of heating and cooling (1 - 60mins) · Adjustable staging turnoffs, i.e. deenergize 2nd 4.0 stage at deadband or keep active until setpoint · Setpoint limiting · Customizable Keypad lock · Secure API (http or https) MODEL B1023 SMART WI-FI RESIDENTIAL 7-DAY PROGRAMMABLE THERMOSTAT UP TO 4 TIME PERIODS PER DAY UP TO 4 HEAT / 2 COOL UNIVERSAL · Programmable fan runs 5 - 60mins per hour with adjustable Start/Stop times. 7-day programmable. Model # B1022 · Smart recovery auto-adjusts Morning start time to meet setpoint by programmed start time it (PN # B1021) (PN # B1028) · Wireless (Wi-Fi) Remote Sensors available · Remote sensor averaging with thermostat sensor · Supply Air Alerts for heating and cooling cycles · Separately tracks up to 2,000 hours of heating, aux heat, and cooling runtime · FDD (Equipment Fault Protection) notification · Email Alerts: Supply Air, Hi/Lo Temp, Hi/Lo Humidity, Service Filter, etc. · Title 24 compliant · Energy Star certified 5.25 Model # B1023 COMPATIBLE ACCESSORIES Model No. Description CTSWFTS Wireless Wi-Fi Mini Sensor CTSHTS CTSDTS Part # B1021 Wired Indoor/Outdoor Sensor Wired Duct Sensor LXPLATE CTS Wall Plate (7.0 W x 5.5 H) ADDWIRE Add-A-Wire makes 4 wires work like 5 CERTS ALERTS SENSORS FAN OPS SECURITY www.olimpiasplendidusa.com B1023 07/21 27 PRODUCT SPECIFICATIONS Conventional (4H/2C) or Heat Pump (4H/2C) Electric Rating: Output Rating: Control Range: 20-28VAC, 5 VA Max Y1, Y2, G 0.8A, all others 0.4A 3A total max on all outputs 35° - 99° F (2° - 36° C) Control Accuracy: +/- 2° F (+/- 1° C) Humidity Accuracy: Remote or Outdoor Sensor: Inputs: +/- 10% RH from 30-70% RH, 50°-90° F (2), 10K NTC Thermistor Sensor terminals: FDD (equip. fault) Outputs: Y1, Y2, G, W1/O/B, W2, W3 Connectivity: integrated 2.4 GHz b/g/n wifi module MODEL B1023 COMPETITIVE CROSS-REFERENCE Honeywell Emerson Braeburn PRO1 TH8110R TH8320R TH8320WF 1F97-1277 1F95-1277 1F95-1280 6100 6300 6425 7320 T855i T905 T955 T955 TERMINAL DESIGNATIONS Terminal Designations R 24 VAC Return G Fan Relay W1/O/B 1st Stage Heat Circuit or Reversing Valve C SENSOR 24 VAC Return Remote or Outdoor Sensor or FDD for equipment fault detection W2 2nd Stage Heat Circuit* W3 3rd Stage Heat Circuit** Y1 1st Stage Compressor (Cool or Heat) Y2 2nd Stage Compressor (Cool or Heat) *3rd stage heat for heat pumps with two compressor stages **4th stage heat for heat pumps with two compressor stages www.olimpiasplendidusa.com 2 28 B1023 07/21 CERTS ALERTS SENSORS SECURITY DISPLAY STAGING PROGRAMS MODEL B1027 SMART WI-FI* RESIDENTIAL 7-DAY PROGRAMMABLE THERMOSTAT UP TO 4 TIME PERIODS PER DAY UP TO 2 HEAT / 1 COOL UNIVERSAL · 7-day, 5+1+1 day or 1-day programmable with up to 4 time periods per day · Vacation mode · Geofencing with Wi-Fi Module · Adjustable first stage deadband (1° - 6° F) · Fixed 2° second stage deadband 4.6 · Choice of English, Spanish, or French · Bi-color LED indicates heating or cooling · Adjustable backlight intensity · Backlit, color coded buttons and legends · Keypad lock · Secure API (http or https) with WFM module · Outdoor sensor ready with Hi/Low readouts for the day · Dry contact input for twist timers, etc. or . . . · Condensate overflow warning systems lockout compressor with display message · FDD (Equipment Fault Protection) notification · Initiate Vacation Mode · Title 24 compliant with Wi-Fi Module · Energy Star certified with Wi-Fi Module *When paired with optional Wi-Fi module (see below) 5.2 COMPATIBLE ACCESSORIES Model No. Description WFM Wi-Fi Module CTSHTS Wired Outdoor Sensor PLATE LX Wall Plate ADDWIRE Add-A-Wire makes 4 wires work like 5 29 MODEL B1027 PRODUCT SPECIFICATIONS Conventional (2H/1C) or Heat Pump (2H/1C) Electric Rating: Output Rating: Control Range: 20-28VAC, 5 VA Max Y1, G 0.8A, all others 0.4A 3A total max on all outputs 35° - 99° F (2° - 36° C) Control Accuracy: +/- 2° F (+/- 1° C) Outdoor Sensor: Inputs: Outputs: (2), 10K NTC Thermistor Dry contact: FDD alerts, condensate alarms, twist timers, etc. Y1, G, W1/0/B, W2 Connectivity: optional 2.4 GHz b/g/n wifi module COMPETITIVE CROSS-REFERENCE Honeywell Emerson Braeburn PRO1 TH5110D TH6110D TH6210U* 1F83H-21PR 1F83C-11NP 1F83H-21NP 1F83C-11PR 1F85-0422 2020 3020 5020 5310 T801 T805 TERMINAL DESIGNATIONS Terminal Designations R 24 VAC Return G Fan Relay W1/O/B 1st Stage Heat Circuit or Reversing Valve W2 2nd Stage Heat Circuit* Y1 1st Stage Compressor (Cool or Heat) C 24 VAC Return Dry Contact Outdoor Sensor Dry Contact Connections Outdoor Sensor Connections 2 30 WIRLESS THERMOSTAT SPEC SHEET PAPRARTT ##B0B0X00X1 X Wireless Universal Up to 2 Heat 2 Cool Conventional Up to 3 Heat 2 Cool Heat Pump Battery or Hardwire 7 Day - 5/1/1 or Non-Programmable This model features: · Pre OCC Fan Purge · Occupied/Unoccupied Programming · Equipment Check/ Change Reminders · 5 Year Warranty · Humidity Control · Light Commercial settings · Keypad lockout · Set dual fuel balance points (requires RZ250W) · Connects up to 4 indoor remotes (RZ251W) for averaging or priority control · Connect to outdoor sensor (RZ250W) · Seperate heating and cooling swing (cycle rate) adjustments · Heating and cooling setpoint limits · Touchscreen Specifications: Frequency Application/Stages Programmability Changeover Display Range Control Range Display Accuracy Heat Swing Cool Swing Terminals Load Rating Power Source Operating Ambient Operating Humidity Mounting Dimensions (Stat) Dimensions (Module) Warranty Switch Positions (System) Switch Systems (Fan) Color Switch Type Elec. Connections Display Size 916 MHZ Up to 2 heat, 2 cool conventional / Up to 3 heat, 2 cool heat pump 7 day, 5-1-1 or Non-Programmable Auto or Manual 41°F to 95°F (5°C to 35°C) 44°F to 90°F (7°C to 32°C) +/- 1°F Adjustable from 0.2°F to 2.0°F Adjustable from 0.2°F to 2.0°F Rc, Rh, C, Y, Y2, W/E, W2, G, B, O, H, D 1 amp per terminal, 1.5 amp maximum all terminals combined 18 to 30 VAC, NEC Class II, 50/60 Hz for hardwire (common wire) Battery power from 2 AA Alkaline batteries 32°F to +105°F (0°C to +41°C) 90% non-condensing maximum Wall or Junction Box 4.7"W x 4.4"H x 1.1"D (119mm W x 112mm H x 28mm D) 4.4" x 4.4" x 1.1"D 5 year warranty Heat / Off / Cool / Auto / Em. Heat On / Auto White Relay Screw Terminals 13 sq. Inches 31 Data Sheet - B0981 BACnet Communicating Thermostat for Single and Multi-Stage Heat Pump Operation The BASstat series of BACnet-compliant wired or wireless communicating thermostats ensure easy integration into BACnet/IP (Wi-Fi) or BACnet MS/TP (EIA-485) networks. The BAST-321HP is suited for heating, cooling, and ventilation with binary output control for single and multi-stage heat pumps with or without 3rd stage auxiliary heat. An adaptive control algorithm saves energy and ensures comfort for the occupants. Three sensing options are available: built-in temperature sensor, input for a remote temperature sensor, or temperature network command from a Building Automation System (BMS). Reversing valve (O/B) logic is buttons, a wired ESI input, or over the BACnet network. Thermostat buttons are optionally lockable to prevent tampering. Digital display with graphic icons is easy to read and understand. Versatile BACnet Communication in Two Distinct Models · BACnet MS/TP in B2 models with MS/TP baud rates 9.6kbps - 76.8kbps (BTL Listed) · BACnet/IP in BW2 models with 802.11 b/g/n 2.4GHz Wi-Fi · Both B2 and BW2 models are BACnet compliant with a Flexible Installation · 24VAC (+/-10%) power input · Digital Display with graphic icons of operation, °C or °F display · Single or Multi-stage, low voltage binary outputs for heat pump applications · · Manual or Auto-changeover modes · consumption calculations Wi-Fi · Selectable built-in temperature sensor or remote temperature sensor input (NTC Thermistor 3k) · Occupied / Unoccupied mode can be switched locally by the user, by using a separate occupancy sensor, or remotely by the BMS headend · Gain, Integral Rate, Stage Widths, Deadband · Short Cycle Delay, Maximum Cycles Per Hour · Stand-alone operation with BACnet setpoint and schedule supervision or optional full BMS control · Non-volatile memory retains user settings during power loss · Lockable user interface · Operating Environment: 0-50°C, 5-95% RH (non- condensing) · Mounts directly onto wall, panel, standard 65×65 mm junction box (hole pitch 60 mm) or standard 2×4 inch vertical junction box (hole pitch 83.5 mm) DS-BAST321H-AA0 32 Data Sheet - B0981 BASstat Overview The BASstat's backlit LCD display is large and easy to read. It incorporates graphic icons to indicate current state of operation: Active Mode, Cooling stage 1 or 2, Heating stage 1, 2, or 3, Ventilation Only, Fan Active, Occupancy Status, and Clock icon to indicate Short Cycle Delay or Max Cycles per hour active waiting state. Six buttons on the BASstat allow users to adjust temperature set points, change HVAC modes, turn the thermostat ON/OFF, and more. Pressing the Set and Up/ Down buttons can manually toggle the thermostat from occupied/unoccupied modes where BACnet occupancy command is not an option. Front panel buttons are lockable to prevent user tampering. These buttons can also be locked individually, making the BASstat suitable for applications where limited user control is desired. space temperature sensor is available. Featuring an NTC type 3k thermistor, the temperature sensor is directly compatible with any BASstat model. Set-Point Icon Displays set-point temperature while Indicates working in Cooling mode Rising Steam Icon Indicates working in Heating mode Wind Icon Indicates working in Ventilation mode Indicates mechanical Cooling/Heating Stage is engaged Fan Status Icons Indicate Fan status AUTO or Continuous. AUTO state when displayed. Fan active when icon is spinning. Fan speed indicator bars (some models are 1 speed only). LCD Displays temperature and working status "1" Icon "2" Icon "3" Icon Cooling/Heating stage 1 on Cooling/Heating stage 2 on Aux Heating stage 3 on Sun Icon Indicates Occupied status Moon Icon Indicates Unoccupied Status Indicates Short Cycle Delay or Max. Cycles per Hour for mechanical stages DP Wi-Fi ACTIVE and connecting to ing. Icon disappears upon successful connection. (BW2 Wi-Fi model only) MODE Button Changes modes Heat/Cool/Vent button in Engineering menu FAN Button Toggle to change Fan mode: Auto or Continuous UP & DOWN Buttons Increase & decrease setting or previous/next item. Hold both buttons for 5 sec. to enter Engineering mode. SET Button Toggle Occupied/ Unoccupied Setting ON/OFF Button Turn thermostat On or Off 2 DS-BAST321H-AA0 33 Data Sheet - B0981 Wiring Diagram Wiring: 14 to 22 AWG wires or 1.5mm2 wires. Mounts directly onto wall, panel, standard 65×65mm junction box (hole pitch 60 mm) or standard 2×4-inch vertical junction box (hole pitch 83.5mm). EIA-485 connection to pins 16(D+) and 17(D-) applicable to B2 - BACnet MS/TP model only. BW2 model uses Wi-Fi connectivity 4 mm T 1 2 3 4 5 6 7 8 9 R C O/B Y1 Y2 W G 24VAC EIA-485 RS ESI D+ D10 11 12 13 14 15 16 17 18 6 mm 83.5 mm Dimensions (all dimensions are in mm) Width: 94mm Height: 118mm Depth: 34mm 118 mm 34 mm 34 60 mm MODE + 118 mm SET 94 mm 3 DS-BAST321H-AA0 Functional Compliance Protocols supported Cable length Wi-Fi range Authentication Maximum Number of Devices Temperature Display Range Temperature Display Resolution Temperature Accuracy Electrical Input Voltage (V, ± 10%) Power Frequency Environmental/Mechanical Operating temperature Storage temperature Relative humidity Protection Weight Regulatory Compliance CE Mark; RoHS BW2 model Wi-Fi FCCID Data Sheet - B0981 B2 model EIA-485 BACnet MS/TP 4000 ft/1200 m @76.8kbps (max) N/A BW2 model IEEE 802.11b, 802.11g, 802.11n (single stream) 16.5dBm@11b, 14.5dBm@11g 13.5dBm@11n Frequency range: 2400MHz~2484MHz BACnet/IP N/A (depending on obstructions) 54Mbps max data rate N/A 32 MS/TP devices (max) -10 to +60°C (14 to 140°F) 0.1°F (0.1°C) ±1.0°C (±1.8°F) with WEP, WPA/WPA2 PSK N/A or depending on Wi-Fi router performance -10 to+ 60°C (14 to 140°F) 0.1°F (0.1°C) ±1.0°C (±1.8°F) with AC only 24 VAC 5 VA 4763 Hz 0°C to 50°C -10°C to +60°C 595%, noncondensing IP30 0.44 lbs. (.2 kg) AC only 24 VAC 5 VA 4763 Hz 0°C to 50°C -10°C to +60°C 595%, noncondensing IP30 0.44 lbs. (.2 kg) P53-EMW3165-P 4 DS-BAST321H-AA0 35 ACCESSORY SUBMITTALS (Sidewall Adapter, PTAC Retrofit Kit, Square Louvred Grill and Rectangle Louvred Grill) Optional bug screen Square Louvred Grill and Rectangle Louvred Grill Square Louvred Grill Part #: B1025 Rectangle Louvred Grill Part #: B1026 Sidewall Adapter Part #: B0976 (Right Handed) 8.0" - Round Part #: B0977 (Left Handed) 8.0" - Round Part #: B0978 (Right Handed) - Rectangle Part #: B0979 (Left Handed) - Rectangle 36 PTAC Retrofit Kit Part #: B0963 LOUVRED GRILLE ALCOCUEVSRSEODRGYRILLE ACCESSORY MODEL B1026 MODEL B1026 SPEC SHEET SPEC SHEET ____________________________________________________________________________________________________________________________________________________________________________ 4-3/8" 2" 4-3/8" 2" 8" 8" 2" 8" 8" 3/8" 4-3/8" ES: Aluminum cons·trucGtiRonIL1L.E5"Sd: eAelupm, 1in/8u"mthcicokn,swtruithcti1o"nO1u.5te"rdFeleapn,g1e/8a"ntdhi2ckC,owninthec1t"ioOnuPteorinFtlsange and 2 Connection Points RES: 1" deep @ 45°·anLgOleU, 1V"RoEnSc:e1n"tedreep @ 45° angle, 1" on center : Galva·nizeTdRAstNeeSlIT(2IO8 NgaBuOgeX):2G" adleveapnizweitdhstwteoel8("2r8oguanudgceo)ll2a"r dsleeeepvewdithucttwsose8t" round collar sleeve ducts set 16" on center, pitched w1i2th-1¾1/"1b6e"nodnocnenbtoetrt,opmitcahneddnwoitdhiv¾id"ebrend on bottom and no divider NSIONS: Opening si·ze:D2I3M"EWNidSeIOxN1S0:-1O/4p"enHiinggh;sOizeve: r2a3ll": W24id-3e/8x"1W0-id1e/4x" H11ig-h5;/8O""vHeriaglhl: 24-3/8" Wide x 11-5/8"" High · CT NAME: PROJECT NAME: CATION: JOB LOCATION: TRIBUTOR: REP/DISTRIBUTOR: ECT/ENGINEER: ARCHITECT/ENGINEER: NICAL CONTRACMTEOCRH: ANICAL CONTRACTOR: DATE: NOTES: NOTES: SPLENDID USAOLIMPIA SPLENDID USA 951) 534-8901 Ph: (951) 534-8901 [email protected] iasplendidusa.cowmww.olimpiasplendidusa.com 37 LOUVRED GRILLE ALCOCUEVSRSEODRYGRILLE ACCESSORY MODEL B1025 MODEL B1025 SPEC SHEET SPEC SHEET 8" 4" ___________________________________________________________________________________________________________________________________________________________________________ ES: Aluminum constr·uctGioRnI1L.L5E" Sde: eAplu,m1/i8n"umthicko,nwstirtuhc1ti"oOn u1t.e5r" Fdleaenpg,e1a/8n"dth1icCko, nwnitehct1io" nOPutoeinr tFlange and 1 Connection Point RES: 1" deep @ 45° a·ngLleO,U1V" oRnEcSe:n1t"edr eep @ 45° angle, 1" on center SITION BOX: Galvan·izeTdRsAteNelS(I2T8IOgNauBgOe)X2:"Gdaelevapnwizitehdosntee8l"(2ro8ugnaducgoel)la2r"sdleeeevpewdiuthctosn, epi8tc"hreodunwdithco¾lla" r sleeve ducts, pitched with ¾" n bottom bend on bottom SIONS: Opening siz·e: 1D0I"MWEiNdSeIxO1N0S-1: /O4"peHniginhg; Osivzer:a1ll0:"1W1-i3d/e8"xW10id-e1/x4"1H1-ig5h/8;"OHviegrhall: 11-3/8" Wide x 11-5/8" High T NAME: PROJECT NAME: CATION: JOB LOCATION: TRIBUTOR: REP/DISTRIBUTOR: ECT/ENGINEER: ARCHITECT/ENGINEER: ICAL CONTRACTMOERC:HANICAL CONTRACTOR: DATE: NOTES: NOTES: SPLENDID USA OLIMPIA SPLENDID USA 51) 534-8901 Ph: (951) 534-8901 [email protected] asplendidusa.comwww.olimpiasplendidusa.com 38 SIDE WALL ADAPTER SUBMITTAL B0976 (Right Handed shown) 8" Round 39 SIDE WALL ADAPTER SUBMITTAL B0977 (Left Handed shown) 8" Round SIDE WALL ADAPTER SUBMITTAL B0978 (Right Handed shown) Rectangle SIDE WALL ADAPTER SUBMITTAL B0978 (Left Handed shown) Rectangle WINDOW SILL ADAPTER B0974 6.13 7.86 5.50 16.38 16.38 12.61 7.11 7.75 21.86 7.40 35.60 12.70 8.00 TYP.2 40 PTAC RETROFIT KIT B0963 16.65 20.72 13.75 13.75 8.95 15.50 11.60 45.50 12.70 8.00 TYP.2 41 SUB BASE 42 3.63 8.50 .15 TYP.4 2.50 35.60 VIEW 1-1 FRONT RECESSED PANEL KIT AND INSTALLATION HOUSING Maestro Pro Series - Model Number #1925, #2234, #2283. Part Numbers - B0775 & B0776 8 7 6 5 4 3 2 1 D TOP VIEW 8.900 3D VIEW SIDE VIEW C 1.1'' FLG 3 SIDES .5 .500 FRONT VIEW B A 4.500 28.630 DETAIL A SCALE 1 : 5 26.78 OD 26.94 ID 27.50 OD A 40.770 8 7 DESCRIPTION: 6 5 OLIMPIA SPLENDID USA ~ MAESTRO RECESSED PANLE KIT TOLERANCES: DRAWN BY DATE CHECKED BY DATE RE THIRD ANGLE PROJECTION .X +/- 0.060 SAL R. 11-20-2021 N/ .XX +/- 0.030 .XXX +/- 0.015 CUSTOMER : SHEET: 1 1 Angle +/- 1 MATERIAL : ALL 18 GA PAINT GRIP ALL BENDS ARE 90 UNLESS SPECIFIED PART NUMBERS : B0775 & B0776 4 3 2 1 43 SOUND PRESSURE DECIBEL Noise source SOUND TRANSMISSION Sound Transmission Class (STC) 36 dB(A) Outdoor to Indoor Transmission Class (OITC) 25 dB(A) 44 CERTIFICATIONS California Energy Commissions (CEC) 45 ETL CERTIFICATION 46 ETL CERTIFICATION AUTHORIZATION TO MARK This authorizes the application of the Certification Mark(s) shown below to the models described in the Product(s) Covered section when made in accordance with the conditions set forth in the Certification Agreement and Listing Report. This authorization also applies to multiple listee model(s) identified on the correlation page of the Listing Report. This document is the property of Intertek Testing Services and is not transferable. The certification mark(s) may be applied only at the location of the Party Authorized To Apply Mark. Applicant: Address: OLIMPIA SPLENDID S.P.A. Via Industriale 1/3 25060 CELLATICA (BS) Manufacturer: Address: OLIMPIA SPLENDID S.P.A. Via Industriale 1/3 25060 CELLATICA (BS) Country: Italy Country: Italy Party Authorized To Apply Mark: Same as Manufacturer 0 1 Report Issuing Office: Intertek Italia SpA Control Number: 5009604 Authorized by: for L. Matthew Snyder, Certification Manager This document supersedes all previous Authorizations to Mark for the noted Report Number. This Authorization to Mark is for the exclusive use of Intertek's Client and is provided pursuant to the Certification agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this Authorization to Mark. Only the Client is authorized to permit copying or distribution of this Authorization to Mark and then only in its entirety. Use of Intertek's Certification mark is restricted to the conditions laid out in the agreement and in this Authorization to Mark. Any further use of the Intertek name for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. Initial Factory Assessments and Follow up Services are for the purpose of assuring appropriate usage of the Certification mark in accordance with the agreement, they are not for the purposes of production quality control and do not relieve the Client of their obligations in this respect. Intertek Testing Services NA Inc. 545 East Algonquin Road, Arlington Heights, IL 60005 Telephone 800-345-3851 or 847-439-5667 Fax 312-283-1672 Standard(s): Household And Similar Electrical Appliances, Part 1: General Requirements [UL 60335-1:2016 Ed.6] Household and Similar Electrical Appliances - Part 2 - 40: Particular Requirements for Electrical Heat Pumps, Air-Conditioners, and Dehumidifiers [UL 60335-2-40:2019 Ed.3] Safety of Household and Similar Appliances - Part 1: General Requirements [CSA C22.2#60335-1:2016 Ed.2] Household and Similar Electrical Appliances - Safety - Part 2-40: Particular Requirements for Electrical Heat Pumps, Air-Conditioners and Dehumidifiers [CSA C22.2#60335-2-40:2019 Ed.3] Product: Room Air Conditioners Brand Name: OLIMPIA SPLENDID Models: MAESTRO PRO INVERTER 12HP RVU, MAESTRO PRO INVERTER 12HP RVUX. ATM for Report 200030547UDI-ETL Page 1 of 1 ATM Issued: 21-Dec-2022 ED 16.3.15 (1-Jul-2022) Mandatory 47 ETL CERTIFICATION AUTHORIZATION TO MARK This authorizes the application of the Certification Mark(s) shown below to the models described in the Product(s) Covered section when made in accordance with the conditions set forth in the Certification Agreement and Listing Report. This authorization also applies to multiple listee model(s) identified on the correlation page of the Listing Report. This document is the property of Intertek Testing Services and is not transferable. The certification mark(s) may be applied only at the location of the Party Authorized To Apply Mark. Applicant: Address: Country: Contact: Phone: FAX: Email: OLIMPIA SPLENDID S.P.A. Via Industriale 1/3 25060 CELLATICA (BS) Italy Mr. Patrick LO PRESTI (+39) 030 319 5235 (+39) 030 373 1882 [email protected] Manufacturer: Address: Country: Contact: Phone: FAX: Email: OLIMPIA SPLENDID S.P.A. Via Industriale 1/3 25060 CELLATICA (BS) Italy Mr. Patrick LO PRESTI (+39) 030 319 5235 (+39) 030 373 1882 [email protected] Party Authorized To Apply Mark: Same as Manufacturer Report Issuing Office: INTERTEK ITALIA SPA - Campoformido (Udine) - Italy Control Number: 5009604 Authorized by: for L. Matthew Snyder, Certification Manager 48 This document supersedes all previous Authorizations to Mark for the noted Report Number. This Authorization to Mark is for the exclusive use of Intertek's Client and is provided pursuant to the Certification agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this Authorization to Mark. Only the Client is authorized to permit copying or distribution of this Authorization to Mark and then only in its entirety. Use of Intertek's Certification mark is restricted to the conditions laid out in the agreement and in this Authorization to Mark. Any further use of the Intertek name for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. Initial Factory Assessments and Follow up Services are for the purpose of assuring appropriate usage of the Certification mark in accordance with the agreement, they are not for the purposes of production quality control and do not relieve the Client of their obligations in this respect. Intertek Testing Services NA Inc. 545 East Algonquin Road, Arlington Heights, IL 60005 Telephone 800-345-3851 or 847-439-5667 Fax 312-283-1672 Standard(s): Household And Similar Electrical Appliances, Part 1: General Requirements [UL 60335-1:2016 Ed.6] Household and Similar Electrical Appliances - Part 2-40: Particular Requirements for Electrical Heat Pumps, Air-Conditioners, and Dehumidifiers [UL 60335-2-40:2017 Ed.2] Safety of Household and Similar Appliances - Part 1: General Requirements [CSA C22.2#60335-1:2016 Ed.2] Household and Similar Electrical Appliances - Safety - Part 2-40: Particular Requirements for Electrical Heat Pumps, Air-Conditioners and Dehumidifiers [CSA C22.2#60335-2-40:2017 Ed.2] Product: Room Air Conditioner Brand Name: Models: MAESTRO SMART 12 HP ATM for Report 200017214UDI-ETL Page 1 of 1 ATM Issued: 29-Sep-2020 ED 16.3.15 (20-Apr-17) Mandatory /,0,7(':$55$17< 7KDQN\RXIRUSXUFKDVLQJWKLVMaestro XQLt, which is FRYHUHGE\DOLPLWHG\HDUFRPSUHVVRUD\HDUSDUWVZDUUDQW\Ds well as D\HDUOLPLWHG "No Hassle Unit Replacement Warranty," where should the FRPSUHVVRUIDLOor there is a leak in the refrigeration circuit ZLWKLQWKH ¿UVWPRQWKVIURPGDWHRIVWDUWXS, we will provide a new unit (no labor allowance). All shipping expenses of the new Maestro unit or replacement warranty parts are the responsibility of the distributor/rep or end user 7KHZDUUDQW\SHULRGPHQWLRQHGDERYHDUHRQO\YDOLGLIWKHXQLWLVregistered online https://olimpiasplendidusa.com/warrantyZLWKLQGD\VIURPGDWHRIVWDUWXSAnd if the unit is installed by an installer that has participated in the "mandatory" Maestro Certification training. $OOXQLWVthat are GHHPHGUHSDLUDEOHZLWKLQWKHZDUUDQW\SHULRGDUHWREHVKLSSHGWRDQGIURPD Maestro AXWKRUL]HGSHUYLFH CHQWHU(MASC)DWWKHRZQHU¶VH[SHQVHMASCORFDWLRQVFDQEHIRXQGE\FDOOLQJ2OLPSLD6SOHQGLG7HFKLQFDO6XSSRUW Ext 103 7+,6/,0,7(':$55$17<'2(6127&29(57+()2//2:,1* 'DPDJHFDXVHGE\WUDQVSRUWDWLRQRUKDQGOLQJ 6HUYLFHFDOOVWR\RXUKRPHIRUGHOLYHU\RUSLFNXSLQVWDOODWLRQLQVWUXFWLRQUHSODFHPHQWRIKRXVHIXVHVFRQQHFWLRQRIKRXVHZLULQJRU SOXPELQJRUWRFRUUHFWXQDXWKRUL]HGUHSDLUV )DLOXUHRISURGXFWWRSHUIRUPGXULQJSRZHUIDLOXUHVDQGLQWHUUXSWLRQVRULQDGHTXDWHHOHFWULFDOVHUYLFH 'DPDJHFDXVHGWRWKHSURGXFWE\DFFLGHQWYHUPLQOLJKWQLQJZLQGV¿UHÀRRGVRUDQ\RWKHUDFWVRI*RG 'DPDJHVFDXVHGE\OHDN\RUEURNHQZDWHUSLSHVIUR]HQZDWHUSLSHVUHVWULFWHGGUDLQOLQHVRULQDGHTXDWHRULQWHUUXSWHGZDWHUVXSSO\ 'DPDJHVFDXVHGE\LQDGHTXDWHVXSSO\RIDLU 'DPDJHVFDXVHGE\RSHUDWLQJWKHSURGXFWLQDFRUURVLYHHQYLURQPHQW 5HSDLUVZKHQWKLVSURGXFWLVapplied in other WKDQ VLQJOH/multiIDPLO\KRXVHKROGsXVHRUFRQWUDU\WRWKHLQVWUXFWLRQVGHVFULEHGLQWKH SURGXFWXVHUPDQXDO 'DPDJHUHVXOWLQJIURPDFFLGHQWDOWHUDWLRQPLVXVHDEXVHRULPSURSHULQVWDOODWLRQDSSOLFDWLRQUHSDLURUPDLQWHQDQFH,PSURSHU UHSDLULQFOXGHVWKHXVHRISDUWVQRWDSSURYHGRUVSHFL¿HGE\2OLPSLD6SOHQGLG86$ 1RUPDOPDLQWHQDQFHDVGHVFULEHGLQWKHXVHUPDQXDOVXFKDVFOHDQLQJRUUHSODFLQJ¿OWHUVFOHDQLQJFRLOVHWF 8VHRIDFFHVVRULHVRUFRPSRQHQWVWKDWDUHQRWFRPSDWLEOHor factory approved forWKLVSURGXFW 3URGXFWVZLWKDOWHUHGRUUHPRYHGVHULDOQXPEHUV &KDQJHVLQWKHDSSHDUDQFHRIWKHSURGXFWWKDWGRQRWDIIHFWSURGXFWSHUIRUPDQFH 14. Increases in utility costs and additional utility expenses 15. A completed data sheet, available at www.OlimpiaSplendidUSA.com, must be submitted along with the warranty claim if requesting a replacement unit due to compressor failure. Claims submitted with a missing or incomplete data sheet are subjuct to delays and/or warranty rejection. ',6&/$,0(52),03/,(':$55$17,(6/,0,7$7,212)5(0(',(6 &86720(5¶662/($1'(;&/86,9(5(0('<81'(57+,6/,0,7(':$55$17<6+$//%(352'8&75(3$,525 5(3/$&(0(17$63529,'('+(5(,1&/$,06%$6('21,03/,(':$55$17,(6,1&/8',1*:$55$17,(62) 0(5&+$17$%,/,7<25),71(66)25$3$57,&8/$5385326($5(/,0,7('7221(<($5257+(6+257(67 3(5,2'$//2:('%</$:%87127/(667+$121(<($52/,03,$63/(1','6+$//127%(/,$%/()25&21 6(48(17,$/25,1&,'(17$/'$0$*(668&+$63523(57<'$0$*($1',1&,'(17$/(;3(16(65(68/7,1* )520$1< %5($&+ 2)7+,6 :5,77(1 /,0,7(' :$55$17< 25$1< ,03/,(' :$55$17< 620( 67$7(6$1' 3529,1&(6'2127$//2:7+((;&/86,2125/,0,7$7,212),1&,'(17$/25&216(48(17,$/'$0$*(625 /,0,7$7,216217+('85$7,212),03/,(':$55$17,(6627+(6(/,0,7$7,21625(;&/86,2160$<127 $33/<72<287+,6:5,77(1:$55$17<*,9(6<2863(&,),&/(*$/5,*+76<280$<$/62+$9(27+(5 5,*+767+$79$5<)52067$7(7267$7( 7KLVZDUUDQW\LVVXEMHFWWRFKDQJHZLWKRXWQRWLFHSOHDVHFRQWDFWXVRUFKHFNRXUZHEVLWHIRUODWHVWXSGDWHV 3URGXFW5HJLVWUDWLRQ,QIRUPDWLRQ (THIS SECTION TO BE FILLED OUT BY INSTALLER) Contact Information: Olimpia Splendid USA, Inc. 0RGHO1XPEHUBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBB 870 International Parkway, Suite 120 6HULDO1XPEHUBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBB 'DWHRI3XUFKDVHBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBB 3XUFKDVHGIURPBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBB ,QVWDOODWLRQ&RPSDQ\1DPHBBBBBBBBBBBBBBBBBBBBBBBBBB Flower Mound, TX 75022 [email protected] [email protected] [email protected] Technical Support: 1-800-408-5196 ext:103 ,QVWDOODWLRQ&RPSDQ\3KRQHBBBBBBBBBBBBBBBBBBBBBBBBBB www.OlimpiaSplendidUSA.com 7KHZDUUDQW\SHULRGIRUan XQUHJLVWHUHGXQLWZLOOEH\HDUVIRUFRPSUHVVRU\HDURQSDUWVDQG aGD\XQLWUHSODFHPHQt warranty (as outlined above) To UHJLVWHU\RXUZDUUDQW\,VXEPLW the above information RQOLQHDWhttps://olimpiasplendidusa.com/warranty 7KHFRVWRIUHSDLURUUHSODFHPHQWXQGHUWKHVHH[FOXGHGFLUFXPVWDQFHVVKDOOEHWKHUHVSRQVLELOLW\RIWKHHQGXVHU Rev. 110923 49 50 NOTES 51 THE PRESTIGIOUS ITALIAN DESIGN: THE HISTORY OF OLIMPIA SPLENDID Since 1956, Olimpia Splendid, an Italian based company, has been designing, manufacturing and distributing heating and air conditioning products worldwide. Our tagline, "Home of Comfort" describes our commitment to creating innovative, environmentally friendly products with a one-of-a-kind, made in Italy design. Our goal is to provide customers globally with comfort solutions where they live, work and play. USA (Dallas, Texas) Sales Office ITALY (Cellatica-BS) Headquarters and Manufacturing Plant ITALY (Gualtieri-RE) Distribution Center SPAIN (Madrid) Sales Office BRAZIL (Itajaí) Sales Office GERMANY (Hanover) Sales Office FRANCE (Paris) Sales Office CHINA (Shanghai) Purchasing Office AUSTRALIA NEW ZELAND Sales Office THE NORTH AMERICA SALES OFFICE Olimpia Splendid USA, Inc. 870 International Parkway, Suite 120 Flower Mound, TX 75022, USA www.olimpiasplendiusa.com [email protected] [email protected] [email protected] Technical Support: 1-800-408-5196 ext:103 INSTAGRA Linkedin For more Mastero product information: