TCLP Results for Week of 11/17/97

lld

SYLVANIA CAPSYLITE Lamps LEDVANCE Issue Date October 25 ...

LEDVANCE, LLC 200 Ballardvale Street Wilmington, MA 01923 (978) 570-3227 September 22, 2016 SYLVANIA CAPSYLITE Lamps LEDVANCE Issue Date October 25, 2016

PDF Viewing Options

Not Your Device? Search For Manuals or Datasheets below:


File Info : application/pdf, 2 Pages, 113.13KB

Document DEVICE REPORTTCLP Capsylite ECO Lamps
SYLVANIA® CAPSYLITE® Lamps LEDVANCE Issue Date October 25, 2016
TCLP TEST RESULTS
Toxicity Characteristic Leaching Procedure
SYLVANIA CAPSYLITE® lamps
SYLVANIA CAPSYLITE® lamps pass the existing Federal TCLP limits4. Test results for barium are shown in the following table:

Element  U.S. Federal Limit 
Product 
PAR38
PAR30
PAR20 PAR16 PAR14 Midbreak

Designation
45PAR/CAP/SP 60PAR/CAP/SP 75PAR/CAP/FL 90PAR/CAP/FL 120PAR/CAP/FL 150PAR/CAP/FL 35PAR30LN/CAP/NSP 50PAR30/CAP/NFL 50PAR30LN/CAP/NFL 75PAR30/CAP/FL 75PAR30LN/CAP/NFL 35PAR20/CAP/NSP 50PAR20/CAP/NFL 60PAR16/CAP/NFL 75PAR16/CAP/NSP 35PAR14/HAL/FL/RP/50
42MB/CAP 50A/HAL/CRYSTAL 52MB/CAP 60A/HAL/RP 72MB/CAL 75A/HAL/POST 100A/HAL

Barium 100 mg/l
<0.5
<0.5
<0.5 <1 <2 <1

No. of Samples Tested
12
10
7 5 4
6

LEDVANCE, LLC September 22, 2016

200 Ballardvale Street Wilmington, MA 01923 (978) 570-3227

1. Units are in mg/liter. 2. Tested in accordance with EPA SW846, "Test Methods for Evaluating Solid Waste (Physical/Chemical Methods)." Lamps were
prepared for testing in accordance with NEMA* Standard LL 4** or equivalent protocol designed to reduce test-to-test variability. 3. The above values were obtained from results of testing these products at OSRAM SYLVANIA and at one outside laboratory (names
and addresses available upon request). These values represent the 80% confidence interval of the mean concentration of the analyte as defined in EPA SW846, Chapter Nine. 4. Arsenic, barium, cadmium, chromium, selenium, and silver are not present, or are present at such low concentrations that the appropriate regulatory levels could not possibly be exceeded. This was confirmed by representative tests. 5. It is always the waste generator's responsibility to ensure that lamps are disposed of in accordance with local, state, and federal regulations. Some states and localities have lower limits than the federal TCLP standard and have different statutes and disposal regulations regarding mercury-containing lamps. Therefore, always consult your local and state authorities for disposal information. 6. At the time of original issue (01/03/2001), the U.S. Federal limits and the product data were accurate as shown. 7. The test for barium was ont conducted on this product. However, based on test results of other lamp types manufactured with identical materials and construction, the test for barium is expected to yield the same result as the other types in that family.
* NEMA: National Electrical Manufacturers Association, 1300 North 17th Street, Suite 900, Rosslyn, VA 22209. ** LL 4: Procedures for Incandescent Lamp Sample Preparation and the TCLP
SYLVANIA is a registered trademark of OSRAM, Licensed to LEDVANCE, LLC. ECOLOGIC is a registered trademark of LEDVANCE, LLC