4790541040-E9V2 FCC Report WPT
Samsung Electronics Co Ltd SMS916B GSM/WCDMA/LTE/5G NR Phone BT/BLE, DTS/UNII a/b/g/n/ac/ax, NFC, WPT, and UWB A3LSMS916B A3LSMS916B sms916b
Not Your Device? Search For Manuals or Datasheets below:
File Info : application/pdf, 17 Pages, 416.04KB
Document DEVICE REPORTGetApplicationAttachment.html?id=6216502CERTIFICATION TEST REPORT Report Number. : 4790541040-E9V2 Applicant : SAMSUNG ELECTRONICS CO., LTD. 129 SAMSUNG-RO, YEONGTONG-GU, SUWON-SI, GYEONGGI-DO, 16677, KOREA Model : SM-S916B/DSM, SM-S916B FCC ID : A3LSMS916B EUT Description : GSM/WCDMA/LTE/5G NR Phone + BT/BLE, DTS/UNII a/b/g/n/ac/ax, NFC, WPT and UWB.. Test Standard(s) : FCC 47 CFR PART 15 SUBPART C Date Of Issue: 2022-11-08 Prepared by: UL Korea, Ltd. 26th floor, 152, Teheran-ro, Gangnam-gu Seoul, 06236, Korea Suwon Test Site: UL Korea, Ltd. Suwon Laboratory 218 Maeyeong-ro, Yeongtong-gu, Suwon-si, Gyeonggi-do, 16675, Korea TEL: (031) 337-9902 FAX: (031) 213-5433 REPORT NO: 4790541040-E9V2 FCC ID: A3LSMS916B Revision History Rev. V1 V2 Issue Date 2022-10-27 2022-11-08 Revisions Initial issue Updated to address TCB's Question DATE: 2022-11-08 Revised By Yeonhee Lim Yeonhee Lim Page 2 of 17 UL Korea, Ltd. Suwon Laboratory FORM ID: FCC_15C(04) 218 Maeyeong-ro, Yeongtong-gu, Suwon-si, Gyeonggi-do, 16675, Korea TEL: (031) 337-9902 FAX: (031) 213-5433 UL Korea, Ltd. Confidential This report shall not be reproduced except in full, without the written approval of UL Korea, Ltd. REPORT NO: 4790541040-E9V2 FCC ID: A3LSMS916B DATE: 2022-11-08 TABLE OF CONTENTS 1. ATTESTATION OF TEST RESULTS ................................................................................. 4 2. TEST METHODOLOGY ..................................................................................................... 5 3. FACILITIES AND ACCREDITATION ................................................................................. 5 4. CALIBRATION AND UNCERTAINTY ................................................................................ 6 4.1. MEASURING INSTRUMENT CALIBRATION................................................................ 6 4.2. SAMPLE CALCULATION.............................................................................................. 6 4.3. MEASUREMENT UNCERTAINTY ................................................................................ 6 4.4. DECISION RULE .......................................................................................................... 6 5. EQUIPMENT UNDER TEST ............................................................................................... 7 5.1. DESCRIPTION OF EUT................................................................................................ 7 5.2. MAXIMUM E-FIELD STRENGTH.................................................................................. 7 5.3. PRELIMINARY TEST CONFIGURATIONS ................................................................... 7 WORST-CASE CONFIGURATION AND MODE .................................................................... 8 5.4. MODIFICATIONS.......................................................................................................... 9 5.5. DESCRIPTION OF TEST SETUP ................................................................................. 9 6. TEST AND MEASUREMENT EQUIPMENT ......................................................................12 7. APPLICABLE LIMITS AND TEST RESULTS ...................................................................13 7.1. RADIATED EMISSIONS ..............................................................................................13 7.2. AC MAINS LINE CONDUCTED EMISSIONS...............................................................15 Page 3 of 17 UL Korea, Ltd. Suwon Laboratory FORM ID: FCC_15C(04) 218 Maeyeong-ro, Yeongtong-gu, Suwon-si, Gyeonggi-do, 16675, Korea TEL: (031) 337-9902 FAX: (031) 213-5433 UL Korea, Ltd. Confidential This report shall not be reproduced except in full, without the written approval of UL Korea, Ltd. REPORT NO: 4790541040-E9V2 FCC ID: A3LSMS916B DATE: 2022-11-08 1. ATTESTATION OF TEST RESULTS COMPANY NAME: EUT DESCRIPTION: MODEL NUMBER: SERIAL NUMBER: SAMSUNG ELECTRONICS CO., LTD. GSM/WCDMA/LTE/5G NR Phone + BT/BLE, DTS/UNII a/b/g/n/ac/ax, NFC, WPT and UWB. SM-S916B/DS, SM-S916B R3CT90EXXPJ (RADIATED); DATE TESTED: 2022-09-30 ~ 2022-10-12; APPLICABLE STANDARDS STANDARD CFR 47 Part 15 Subpart C TEST RESULTS Complies UL Verification Services Inc. tested the above equipment in accordance with the requirements set forth in the above standards. All indications of Pass/Fail in this report are opinions expressed by UL Verification Services Inc. based on interpretations and/or observations of test results. Measurement Uncertainties were not taken into account and are published for informational purposes only. The test results show that the equipment tested is capable of demonstrating compliance with the requirements as documented in this report. Note: The results documented in this report apply only to the tested sample, under the conditions and modes of operation as described herein. This document may not be altered or revised in any way unless done so by UL Verification Services Inc. and all revisions are duly noted in the revisions section. Any alteration of this document not carried out by UL Verification Services Inc. will constitute fraud and shall nullify the document. This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, any agency of the Federal Government, or any agency of any government. Approved & Released For UL Korea, Ltd. By: Tested By: Seokhwan Hong Suwon Lab Engineer UL Korea, Ltd. Yeonhee Lim Suwon Lab Engineer UL Korea, Ltd. Page 4 of 17 UL Korea, Ltd. Suwon Laboratory FORM ID: FCC_15C(04) 218 Maeyeong-ro, Yeongtong-gu, Suwon-si, Gyeonggi-do, 16675, Korea TEL: (031) 337-9902 FAX: (031) 213-5433 UL Korea, Ltd. Confidential This report shall not be reproduced except in full, without the written approval of UL Korea, Ltd. REPORT NO: 4790541040-E9V2 FCC ID: A3LSMS916B DATE: 2022-11-08 2. TEST METHODOLOGY The tests documented in this report were performed in accordance with following methods. 1. FCC CFR 47 Part 2. 2. FCC CFR 47 Part 15. 3. ANSI C63.10-2013. 4. 680106 D01 RF Exposure Wireless Charging Apps v03r01. 3. FACILITIES AND ACCREDITATION The test sites and measurement facilities used to collect data are located at 218 Maeyeong-ro, Yeongtong-gu, Suwon-si, Gyeonggi-do, 16675, Korea. Line conducted emissions are measured only at the 218 address. The following table identifies which facilities were utilized for radiated emission measurements documented in this report. Specific facilities are also identified in the test results sections. 218 Maeyeong-ro Chamber 1(3m semi-anechoic chamber) Chamber 2(3m semi-anechoic chamber) Chamber 3(3m semi-anechoic chamber) Chamber 4(3m Full-anechoic chamber) Chamber 5(3m Full-anechoic chamber) UL Korea, Ltd. is accredited by IAS, Laboratory Code TL-637. The full scope of accreditation can be viewed at https://www.iasonline.org/wp-content/uploads/2017/05/TL-637-cert-New.pdf. Page 5 of 17 UL Korea, Ltd. Suwon Laboratory FORM ID: FCC_15C(04) 218 Maeyeong-ro, Yeongtong-gu, Suwon-si, Gyeonggi-do, 16675, Korea TEL: (031) 337-9902 FAX: (031) 213-5433 UL Korea, Ltd. Confidential This report shall not be reproduced except in full, without the written approval of UL Korea, Ltd. REPORT NO: 4790541040-E9V2 FCC ID: A3LSMS916B DATE: 2022-11-08 4. CALIBRATION AND UNCERTAINTY 4.1. MEASURING INSTRUMENT CALIBRATION The measuring equipment utilized to perform the tests documented in this report has been calibrated in accordance with the manufacturer's recommendations, and is traceable to recognized national standards. 4.2. SAMPLE CALCULATION Where relevant, the following sample calculation is provided: Field Strength (dBuV/m) = Measured Voltage (dBuV) + Antenna Factor (dB/m) + Cable Loss (dB) Preamp Gain (dB) 36.5 dBuV + 18.7 dB/m + 0.6 dB 26.9 dB = 28.9 dBuV/m Corrected Reading (dBuV) = Meter Reading (dBuV) + External Cable (dB) + Cableloss (dB) 46.62 dBuV + 9.8 dB + 0.1 dB = 56.52 dBuV 4.3. MEASUREMENT UNCERTAINTY Where relevant, the following measurement uncertainty levels have been estimated for tests performed on the apparatus: PARAMETER UNCERTAINTY Conducted Disturbance, 0.15 to 30 MHz 3.02 dB Radiated Disturbance, 9 kHz to 30 MHz 1.72 dB Radiated Disturbance, 30 MHz to 1 GHz 4.05 dB Uncertainty figures are valid to a confidence level of 95%. 4.4. DECISION RULE Decision rule for statement(s) of conformity is based on Procedure 2, Clause 4.4.3 in IEC Guide 115:2007. Page 6 of 17 UL Korea, Ltd. Suwon Laboratory FORM ID: FCC_15C(04) 218 Maeyeong-ro, Yeongtong-gu, Suwon-si, Gyeonggi-do, 16675, Korea TEL: (031) 337-9902 FAX: (031) 213-5433 UL Korea, Ltd. Confidential This report shall not be reproduced except in full, without the written approval of UL Korea, Ltd. REPORT NO: 4790541040-E9V2 FCC ID: A3LSMS916B DATE: 2022-11-08 5. EQUIPMENT UNDER TEST 5.1. DESCRIPTION OF EUT The EUT is a GSM/WCDMA/LTE/5G NR Phone + BT/BLE, DTS/UNII a/b/g/n/ac/ax and NFC, WPT and UWB. This test report addresses the CDC (WPT) operational mode. This report covers the Samsung models SM-S916B/DS and SM-S916B. These models are identical in hardware except SM-S916B has single SIM tray. With some pre-scan, model SM-S916B/DS was set for final test. 5.2. MAXIMUM E-FIELD STRENGTH - Power sharing mode Fundamental Frequency Mode [kHz] 110 - 148 Charging E-field (300m distance) FCC[dBuV/m] -0.16 5.3. PRELIMINARY TEST CONFIGURATIONS The Power Sharing mode of the EUT was investigated in three orthogonal orientations X, Y and Z it was determined that Y orientation was worst-case orientation; therefore, radiated testing was reported with the EUT in Y orientation. Page 7 of 17 UL Korea, Ltd. Suwon Laboratory FORM ID: FCC_15C(04) 218 Maeyeong-ro, Yeongtong-gu, Suwon-si, Gyeonggi-do, 16675, Korea TEL: (031) 337-9902 FAX: (031) 213-5433 UL Korea, Ltd. Confidential This report shall not be reproduced except in full, without the written approval of UL Korea, Ltd. REPORT NO: 4790541040-E9V2 FCC ID: A3LSMS916B WORST-CASE CONFIGURATION AND MODE DATE: 2022-11-08 Mode Test Case 1 Description Charging from EUT to Phone 2 Charging from EUT(Charging from TA) to Phone Power sharing mode 3 Charging from EUT to Phone (Cross position) 4 Charging from EUT(Charging from TA) to Phone (Cross position) 5 Charging from EUT to Wearable device 6 Charging from EUT(Charging from TA) to Wearable device For radiated test, test case 1/3/5, the EUT can operate the power sharing mode when battery level is over 30%. Because test results are not different between fully charged status and battery level 30% status(EUT condition), test were performed fully charged condition. Also according to current client device's(Phone and Wearable device) battery level, test results are different.Because the test results were worst when the battery level was 1%~20%, tests were performed when the battery level was 1%~20%.(Client device) During radiated test for test case 1/3/5, the EUT didn't connected AC adapter, but for AC line conducted test for all test case was performed with connected with AC adapter. For power sharing mode, test results of case 5 is worst, so this test report described test case 5. Page 8 of 17 UL Korea, Ltd. Suwon Laboratory FORM ID: FCC_15C(04) 218 Maeyeong-ro, Yeongtong-gu, Suwon-si, Gyeonggi-do, 16675, Korea TEL: (031) 337-9902 FAX: (031) 213-5433 UL Korea, Ltd. Confidential This report shall not be reproduced except in full, without the written approval of UL Korea, Ltd. REPORT NO: 4790541040-E9V2 FCC ID: A3LSMS916B DATE: 2022-11-08 5.4. MODIFICATIONS No modifications were made during testing. 5.5. DESCRIPTION OF TEST SETUP SUPPORT EQUIPMENT Support Equipment List Description Manufacturer Model Serial Number Charger SAMSUNG EP-TA800 R37R38J4A28SE3 Data Cable SAMSUNG EP-DN980 GH39-02111ABBE Mobile Phone SAMSUNG SM-G986B R3CMB0C70XN Wearable Device SAMSUNG SM-R835 RFAM90ZXFTF FCC ID N/A N/A A3LSMG986B A3LSMR835 I/O CABLE Cable No. 1 Port DC Power # of identical ports 1 I/O Cable List Connector Type Cable Type C Type Shielded Cable Length (m) 1.0 m Remarks N/A Page 9 of 17 UL Korea, Ltd. Suwon Laboratory FORM ID: FCC_15C(04) 218 Maeyeong-ro, Yeongtong-gu, Suwon-si, Gyeonggi-do, 16675, Korea TEL: (031) 337-9902 FAX: (031) 213-5433 UL Korea, Ltd. Confidential This report shall not be reproduced except in full, without the written approval of UL Korea, Ltd. REPORT NO: 4790541040-E9V2 FCC ID: A3LSMS916B TEST SETUP The EUT is installed in a typical configuration. Charging from EUT. DATE: 2022-11-08 TEST SETUP DIAGRAM NOTE : Test case 1/3/5, EUT did not connected with Travel adapter(AC Main) in below set-up diagram for radiated test. - Test Case1 and 2 : Charging Phone AC Main Adapter 1 2 Charging Phone EUT Page 10 of 17 UL Korea, Ltd. Suwon Laboratory FORM ID: FCC_15C(04) 218 Maeyeong-ro, Yeongtong-gu, Suwon-si, Gyeonggi-do, 16675, Korea TEL: (031) 337-9902 FAX: (031) 213-5433 UL Korea, Ltd. Confidential This report shall not be reproduced except in full, without the written approval of UL Korea, Ltd. REPORT NO: 4790541040-E9V2 FCC ID: A3LSMS916B - Test Case 3 and 4 : Charging Phone(Cross position) AC Main Adapter 1 2 DATE: 2022-11-08 Charging Phone EUT - Test Case 5 and 6 : Charging Wearable device AC Main Adapter 1 2 Wearable device EUT Page 11 of 17 UL Korea, Ltd. Suwon Laboratory FORM ID: FCC_15C(04) 218 Maeyeong-ro, Yeongtong-gu, Suwon-si, Gyeonggi-do, 16675, Korea TEL: (031) 337-9902 FAX: (031) 213-5433 UL Korea, Ltd. Confidential This report shall not be reproduced except in full, without the written approval of UL Korea, Ltd. REPORT NO: 4790541040-E9V2 FCC ID: A3LSMS916B DATE: 2022-11-08 6. TEST AND MEASUREMENT EQUIPMENT The following test and measurement equipment was utilized for the tests documented in this report: Test Equipment List Description Manufacturer Model S/N Cal Due Antenna, Bilog, 30MHz-1GHz SCHWARZBECK VULB9163 845 2024-08-15 Antenna, Bilog, 30MHz-1GHz SCHWARZBECK VULB9163 749 2024-08-15 Preamplifier, 1000 MHz Sonom a 310N 341282 2023-08-02 Preamplifier, 1000 MHz Sonom a 310N 351741 2023-08-02 EMI Test Receive, 40 GHz R&S ESU40 100457 2023-07-29 EMI Test Receive, 3 GHz R&S ESR3 101832 2023-08-01 Spectrum Analyzer, 7 GHz Agilent / HP N9010A MY54200580 2023-08-01 LISN R&S ENV-216 101837 2023-08-04 Antenna, Loop, 9kHz-30MHz R&S HFH2-Z2 100418 2023-10-06 UL Software Description Manufacturer Model Version Radiated software UL UL EMC Ver 9.5 AC Line Conducted software UL UL EMC Ver 9.5 Page 12 of 17 UL Korea, Ltd. Suwon Laboratory FORM ID: FCC_15C(04) 218 Maeyeong-ro, Yeongtong-gu, Suwon-si, Gyeonggi-do, 16675, Korea TEL: (031) 337-9902 FAX: (031) 213-5433 UL Korea, Ltd. Confidential This report shall not be reproduced except in full, without the written approval of UL Korea, Ltd. REPORT NO: 4790541040-E9V2 FCC ID: A3LSMS916B 7. APPLICABLE LIMITS AND TEST RESULTS 7.1. RADIATED EMISSIONS DATE: 2022-11-08 TEST PROCEDURE ANSI C63.10: 2013 The highest clock frequency generated or used in the EUT is 110 kHz therefore the frequency range was investigated from 9 kHz to 30 MHz. LIMIT FCC §15.209 (a) Frequency (MHz) Field Strength (microvolts/meter) Measurement Distance (m) 0.0090.490 2400/F(kHz) 300 0.4901.705 24000/F(kHz) 30 1.70530.0 30 30 3088 100 3 88 to 216 150 3 216 to 960 200 3 Above 960 MHz 500 3 Note: The lower limit shall apply at the transition frequency. RESULTS The EUT belongs to Test Case 5. Although these tests were performed other than open field test site, adequate comparison measurements were confirmed against 300 m open field test site. Therefore sufficient tests were made to demonstrate that the alternative site produces results that correlate with the ones of tests made in an open field based on KDB 414788 D01. Page 13 of 17 UL Korea, Ltd. Suwon Laboratory FORM ID: FCC_15C(04) 218 Maeyeong-ro, Yeongtong-gu, Suwon-si, Gyeonggi-do, 16675, Korea TEL: (031) 337-9902 FAX: (031) 213-5433 UL Korea, Ltd. Confidential This report shall not be reproduced except in full, without the written approval of UL Korea, Ltd. REPORT NO: 4790541040-E9V2 FCC ID: A3LSMS916B RADIATED EMISSIONS 9 KHz to 30 MHz(Power sharing mode Test Case 5) DATE: 2022-11-08 Trace Markers [Face On] Marker Frequency (MHz) Meter Reading (dBuV) Det **1 .11028 59.94 Pk 2 .33261 41.26 Pk 3 .4303 36.99 Pk HFH2Z2_Loop Antenna 19.8 19.7 19.7 Cable Loss .1 .1 .1 Dist Corr 300m -80 -80 -80 Corrected Reading dBuV/m -.16 -18.94 -23.21 Peak Limit (dBuV/m) 46.78 37.17 34.93 Margin (dB) -46.94 -56.11 -58.14 Avg Limit (dBuV/m) 26.78 17.17 14.93 Margin (dB) -26.94 -36.11 -38.14 Azimuth (Degs) 0-360 0-360 0-360 Marker 4 5 6 7 Frequency (MHz) .55262 .66818 .77192 .99848 Meter Reading (dBuV) 32.76 24.63 27.51 24.25 Det HFH2-Z2_Loop Antenna Cable Loss Dist Corr 30m Corrected Reading dBuV/m QP Limit (dBuV/m) Pk 19.7 .1 -40 12.56 32.76 Pk 19.7 .1 -40 4.43 31.11 Pk 19.8 .2 -40 7.51 29.86 Pk 19.8 .2 -40 4.25 27.63 Margin (dB) -20.2 -26.68 -22.35 -23.38 Azimuth (Degs) 0-360 0-360 0-360 0-360 [Face Off] Marker Frequency (MHz) Meter Reading (dBuV) Det **8 .11034 55.72 Pk 9 .33221 36.61 Pk 10 .43171 34.41 Pk HFH2Z2_Loop Antenna 19.8 19.7 19.7 Cable Loss .1 .1 .1 Dist Corr 300m -80 -80 -80 Corrected Reading dBuV/m -4.38 -23.59 -25.79 Peak Limit (dBuV/m) 46.77 37.18 34.9 Margin (dB) -51.15 -60.77 -60.69 Avg Limit (dBuV/m) 26.77 17.18 14.9 Margin (dB) -31.15 -40.77 -40.69 Azimuth (Degs) 0-360 0-360 0-360 Marker 11 12 13 14 Frequency (MHz) .55312 .71754 .7772 1.00707 Meter Reading (dBuV) 28.16 25.18 24.3 22.03 Det HFH2-Z2_Loop Antenna Cable Loss Dist Corr 30m Corrected Reading dBuV/m QP Limit (dBuV/m) Pk 19.7 .1 -40 7.96 32.75 Pk 19.7 .1 -40 4.98 30.5 Pk 19.8 .2 -40 4.3 29.8 Pk 19.8 .2 -40 2.03 27.56 Margin (dB) -24.79 -25.52 -25.5 -25.53 Azimuth (Degs) 0-360 0-360 0-360 0-360 Pk - Peak detector ** Fundamental Note : Radiated test were investigated with three receiving antenna axes: Face-on, Face-off and horizontal (parallel to the ground plane) and the worse orientations of Face-on and Face-off were set for final test. Page 14 of 17 UL Korea, Ltd. Suwon Laboratory FORM ID: FCC_15C(04) 218 Maeyeong-ro, Yeongtong-gu, Suwon-si, Gyeonggi-do, 16675, Korea TEL: (031) 337-9902 FAX: (031) 213-5433 UL Korea, Ltd. Confidential This report shall not be reproduced except in full, without the written approval of UL Korea, Ltd. REPORT NO: 4790541040-E9V2 FCC ID: A3LSMS916B 7.2. AC MAINS LINE CONDUCTED EMISSIONS TEST PROCEDURE DATE: 2022-11-08 ANSI C63.10: 2013 The EUT is placed on a non-conducting table 40 cm from the vertical ground plane and 80 cm above the horizontal ground plane. The EUT is configured in accordance with ANSI C63.10. The receiver is set to a resolution bandwidth of 9 kHz. Peak detection is used unless otherwise noted as quasi-peak or average. Line conducted data is recorded for both NEUTRAL and HOT lines. LIMIT FCC §15.207 (a) Frequency range (MHz) Quasi-peak 0.15 to 0.50 66 to 56* 0.50 to 5 56 5 to 30 60 *Decreases with the logarithm of the frequency. Limits (dBµV) Average 56 to 46* 46 50 RESULTS The EUT belongs to Test Case 6. Page 15 of 17 UL Korea, Ltd. Suwon Laboratory FORM ID: FCC_15C(04) 218 Maeyeong-ro, Yeongtong-gu, Suwon-si, Gyeonggi-do, 16675, Korea TEL: (031) 337-9902 FAX: (031) 213-5433 UL Korea, Ltd. Confidential This report shall not be reproduced except in full, without the written approval of UL Korea, Ltd. REPORT NO: 4790541040-E9V2 FCC ID: A3LSMS916B WORST EMISSIONS(Power sharing mode Test Case 6) DATE: 2022-11-08 LINE 1 RESULTS Range 1: Phase L1 .15 - 30MHz Marker Frequency (MHz) Meter Reading (dBuV) Det 1 .189 38.9 Pk 2 .18 19.62 Av 3 .201 36.5 Pk 4 .225 15.3 Av 5 .225 34.49 Pk 6 .225 15.3 Av 7 .432 31.12 Pk 8 .408 13.69 Av 9 4.323 23.37 Pk 10 4.314 12 Av 11 11.499 20.87 Pk 12 11.499 12.98 Av 101836_Wit h EX_L1[dB] 9.9 9.9 9.8 9.7 9.7 9.7 9.8 9.8 9.7 9.7 9.9 9.9 CABLELOS S(dB) .2 .2 .2 .2 .2 .2 .2 .2 .3 .3 .3 .3 Corrected Reading (dB(uVolts)) 49 29.72 46.5 25.2 44.39 25.2 41.12 23.69 33.37 22 31.07 23.18 CFR 47 FCC PART 15 Class B QP 64.08 - 63.57 - 62.63 - 57.21 56 60 - Margin (dB) -15.08 - -17.07 - -18.24 - -16.09 - -22.63 - -28.93 - CFR 47 FCC PART 15 Class B AV 54.49 52.63 52.63 47.69 46 50 Margin (dB) -24.77 -27.43 -27.43 -24 -24 -26.82 Pk - Peak detector Av - Average detection Page 16 of 17 UL Korea, Ltd. Suwon Laboratory FORM ID: FCC_15C(04) 218 Maeyeong-ro, Yeongtong-gu, Suwon-si, Gyeonggi-do, 16675, Korea TEL: (031) 337-9902 FAX: (031) 213-5433 UL Korea, Ltd. Confidential This report shall not be reproduced except in full, without the written approval of UL Korea, Ltd. REPORT NO: 4790541040-E9V2 FCC ID: A3LSMS916B DATE: 2022-11-08 LINE 2 RESULTS Range 2: Phase N .15 - 30MHz Marker Frequency (MHz) Meter Reading (dBuV) Det 13 .162 35.67 Pk 14 .162 18.21 Av 15 .18 33.5 Pk 16 .186 15.94 Av 17 .222 30.78 Pk 18 .222 12.45 Av 19 .465 25.28 Pk 20 .465 12.16 Av 21 11.82 27.54 Pk 22 11.823 13.88 Av 23 20.457 28.14 Pk 24 20.457 13.42 Av Pk - Peak detector Av - Average detection 101836_Wit h EX_N[dB] 9.9 9.9 9.9 9.9 9.7 9.7 9.9 9.9 9.9 9.9 10.3 10.3 CABLELOS S(dB) .1 .1 .2 .2 .2 .2 .2 .2 .3 .3 .4 .4 Corrected Reading (dB(uVolts)) 45.67 28.21 43.6 26.04 40.68 22.35 35.38 22.26 37.74 24.08 38.84 24.12 CFR 47 FCC PART 15 Class B QP 65.36 - 64.49 - 62.74 - 56.6 60 60 - Margin (dB) -19.69 - -20.89 - -22.06 - -21.22 - -22.26 - -21.16 - CFR 47 FCC PART 15 Class B AV 55.36 54.21 52.74 46.6 50 50 Margin (dB) -27.15 -28.17 -30.39 -24.34 -25.92 -25.88 END OF TEST REPORT Page 17 of 17 UL Korea, Ltd. Suwon Laboratory FORM ID: FCC_15C(04) 218 Maeyeong-ro, Yeongtong-gu, Suwon-si, Gyeonggi-do, 16675, Korea TEL: (031) 337-9902 FAX: (031) 213-5433 UL Korea, Ltd. Confidential This report shall not be reproduced except in full, without the written approval of UL Korea, Ltd.
Related FCC IDs:
- A3LSMS916B - Samsung Electronics Co Ltd GSM/WCDMA/LTE/5G NR Phone + BT/BLE, DTS/UNII a/b/g/n/ac/ax, NFC, WPT, and UWB [SMS916B] Microsoft Word Microsoft 365용 Microsoft Word Microsoft 365용