EN55022&24 report

leon chen

RF Exposure

Shenzhen Tengsay Technology Co., Ltd T29 2BGF3-T29 2BGF3T29 t29

PDF Viewing Options

Not Your Device? Search For Manuals or Datasheets below:


File Info : application/pdf, 12 Pages, 1.18MB

Document DEVICE REPORTGetApplicationAttachment.html?id=7626482
- Page 1 of 12 -

Report No.: HB20240813005E-02

RF EXPOSURE Test Report

Product: 3-in-1 Wireless Charging Station Trade Mark: N/A Model Number: T29
FCC ID: 2BGF3-T29
Prepared for Shenzhen Tengsay Technology Co., Ltd 502, No.7, Xikeng South Road, Xikeng Community, Fucheng Street,
Longhua District, Shenzhen, China
Prepared by Shenzhen HongBiao Certification& Testing Co., Ltd Room 102, 201, Building 2, Yuanwanggu RFID Industrial Park, Tongguan Road, Tianliao Community, Yutang Street, Guangming District, Shenzhen,
China Tel.: +86-755-2998 9321 Fax.: +86-755-2998 5110
Website: http://www.sz-hongbiao.com

Add:Room 102, 201, Building 2, Yuanwanggu RFID Industrial Park, Tongguan Road, Tianliao Community, Yutang Street, Guangming District, Shenzhen,China

Tel: (86-755) 29989321

Fax: (86-755) 29985110

Web:www.sz-hongbiao.com

- Page 2 of 12 -

Report No.: HB20240813005E-02

Table of Contents
1 GENERAL DESCRIPTION ..................................................................................................................................... 5
1.1 DESCRIPTION OF EUT ................................................................................................................................................ 5 1.2 TEST MODE.............................................................................................................................................................. 5 1.3 TEST SETUP .............................................................................................................................................................. 5 1.4 ANCILLARY EQUIPMENT .............................................................................................................................................. 6
2 TEST FACILITIES AND ACCREDITATIONS .............................................................................................................. 7
2.1 TEST LABORATORY ..................................................................................................................................................... 7 2.2 ENVIRONMENTAL CONDITIONS ..................................................................................................................................... 7 2.3 MEASUREMENT UNCERTAINTY ..................................................................................................................................... 7 2.4 TEST SOFTWARE ........................................................................................................................................................ 7
3 LIST OF TEST EQUIPMENT .................................................................................................................................. 8
4 RF EXPOSURE..................................................................................................................................................... 9
4.1 MAXIMUM PERMISSIBLE EXPOSURE .............................................................................................................................. 9 4.1.1. Limit ............................................................................................................................................................ 9 4.1.2. Test Procedures ........................................................................................................................................... 9 4.1.3. Equipment Approval Considerations item 5 b) of KDB 680106 D01 Wireless ........................................... 10 4.1.4. Test Setup .................................................................................................................................................. 10 4.1.5. Test Result ................................................................................................................................................. 11
5 PHOTOGRAPHS OF THE TEST SETUP..................................................................................................................12

Add:Room 102, 201, Building 2, Yuanwanggu RFID Industrial Park, Tongguan Road, Tianliao Community, Yutang Street, Guangming District, Shenzhen,China

Tel: (86-755) 29989321

Fax: (86-755) 29985110

Web:www.sz-hongbiao.com

- Page 3 of 12 -

Report No.: HB20240813005E-02

TEST RESULT CERTIFICATION

Applicant's Name................. : Address ................................. : Manufacturer's Name .......... : Address ................................. : Product description

Shenzhen Tengsay Technology Co., Ltd 502, No.7, Xikeng South Road, Xikeng Community, Fucheng Street, Longhua District, Shenzhen, China Shenzhen Tengsay Technology Co., Ltd 502, No.7, Xikeng South Road, Xikeng Community, Fucheng Street, Longhua District, Shenzhen, China

Product name ........................ : 3-in-1 Wireless Charging Station

Model Number ....................... : T29 Standards ............................. : FCC CFR 47 PART 1 , 1.1310 Test procedure....................... : KDB 680106 D01 Wireless Power Transfer v04 This device described above has been tested by Shenzhen HongBiao Certification& Testing Co., Ltd and the test results show that the equipment under test (EUT) is in compliance with the EMC requirements. And it is applicable only to the tested sample identified in the report.

Date of Test ........................................... :

Date (s) of performance of tests ............. : Aug. 13, 2024~ Aug. 22, 2024

Test Result.............................................. : Pass

Testing Engineer

:

(Zoe Su)

Technical Manager :

(Mark Chen)

Authorized Signatory :

(Leo Su)

Add:Room 102, 201, Building 2, Yuanwanggu RFID Industrial Park, Tongguan Road, Tianliao Community, Yutang Street, Guangming District, Shenzhen,China

Tel: (86-755) 29989321

Fax: (86-755) 29985110

Web:www.sz-hongbiao.com

Revised No. 01

- Page 4 of 12 -

Report No.: HB20240813005E-02

Revision History
Date of Issue Aug. 27, 2024

Description Original

Add:Room 102, 201, Building 2, Yuanwanggu RFID Industrial Park, Tongguan Road, Tianliao Community, Yutang Street, Guangming District, Shenzhen,China

Tel: (86-755) 29989321

Fax: (86-755) 29985110

Web:www.sz-hongbiao.com

- Page 5 of 12 -

Report No.: HB20240813005E-02

1 General Description
1.1 Description of EUT

Product name: Model name: Series Model: Different of series model:
Operation frequency:
Operational mode: Modulation type: Antenna type: Hardware version: Software version: Battery:
Power supply:
Adapter information: 1.2 Test Mode

3-in-1 Wireless Charging Station
T29
N/A
N/A Watch: 320kHz Phone: 115kHz~205kHz TWS: 115kHz~205kHz Wireless charging
ASK
Coil Antenna
V1.0
V1.0
N/A Input: DC 9V/3A Wireless Output: For Phone 15W Max Wireless Output: For iPhone 7.5W Max Wireless Output: For TWS 5W Max Wireless Output: For Watch 3W Max N/A

Pretest Test Mode

Description of Mode

1

Wireless Output (Phone: 5W+TWS: 5W+Watch: 3W)

2

Wireless Output (Phone: 7.5W+TWS: 5W+Watch: 3W)

3

Wireless Output (Phone: 10W+TWS: 5W+Watch: 3W)

4

Wireless Output (Phone: 15W+TWS: 5W+Watch: 3W)

1.3 Test Setup

See photographs of the test setup in the report for the actual setup and connections between EUT and support equipment.

Add:Room 102, 201, Building 2, Yuanwanggu RFID Industrial Park, Tongguan Road, Tianliao Community, Yutang Street, Guangming District, Shenzhen,China

Tel: (86-755) 29989321

Fax: (86-755) 29985110

Web:www.sz-hongbiao.com

- Page 6 of 12 -

Report No.: HB20240813005E-02

1.4 Ancillary Equipment

Equipment Adapter

Model TA65B

AirPods

A2031

Watch

NYYK2CH/A

Load

YBZ1.1

Phone

iPhone 12 Pro

S/N
2S36003438 PL97T09582 H04F3NS0L
X2Y H4HFR0ZHQ
1N2 86631yp378-
220519 DNPF9UL20
D9L

Manufacturer Nanjing Bolande Electronic
Technology Co., Ltd Apple Inc.
Apple Inc.
YBZ
Apple Inc.

Add:Room 102, 201, Building 2, Yuanwanggu RFID Industrial Park, Tongguan Road, Tianliao Community, Yutang Street, Guangming District, Shenzhen,China

Tel: (86-755) 29989321

Fax: (86-755) 29985110

Web:www.sz-hongbiao.com

- Page 7 of 12 -

Report No.: HB20240813005E-02

2 Test Facilities and Accreditations

2.1 Test Laboratory

Test Site
Test Site Location
Telephone: Fax: FCC Registration No.: A2LA Certificate No.:

Shenzhen HongBiao Certification& Testing Co., Ltd Room 102, 201, Building 2, Yuanwanggu RFID Industrial Park, Tongguan Road, Tianliao Community, Yutang Street, Guangming District, Shenzhen, China (86-755) 2998 9321
(86-755) 2998 5110
CN1341
6765.01

2.2 Environmental Conditions

During the measurement the environmental conditions were within the listed ranges:

Temperature:

15ºC~35ºC

Relative Humidity:

20%~75%

Air Pressure:

98kPa~101kPa

2.3 Measurement Uncertainty
The reported uncertainty of measurement y ± U, where expended uncertainty U is based on a standard uncertainty multiplied by a coverage factor of k=2, providing a level of confidence of approximately 95 %.

Measurement Frequency Range RF frequency E-field H-field Temperature Humidity

U(dB) 2x 10-5 ± 2.5 dB ± 4.2 dB ±1 degree ±5 %

Note

2.4 Test Software Software name EHP200-TS

Manufacturer
Narda

Model
EHP-200A

Version Rel 1.95

Add:Room 102, 201, Building 2, Yuanwanggu RFID Industrial Park, Tongguan Road, Tianliao Community, Yutang Street, Guangming District, Shenzhen,China

Tel: (86-755) 29989321

Fax: (86-755) 29985110

Web:www.sz-hongbiao.com

- Page 8 of 12 -

Report No.: HB20240813005E-02

3 List of Test Equipment

Item

Equipment No.

Equipment name

Manufacturer

Electric and

1

HB-E073

Magnetic Field

Narda

Analyzer

Model
EHP-20 0A

Serial No.
180ZX1101 3

Calibration date
2024-05-21

Due date 2025-05-20

Note: the calibration interval of the above test instruments is 12 months and the calibrations are traceable to international system unit (SI).

Add:Room 102, 201, Building 2, Yuanwanggu RFID Industrial Park, Tongguan Road, Tianliao Community, Yutang Street, Guangming District, Shenzhen,China

Tel: (86-755) 29989321

Fax: (86-755) 29985110

Web:www.sz-hongbiao.com

- Page 9 of 12 -

Report No.: HB20240813005E-02

4 RF Exposure

4.1 Maximum Permissible Exposure

4.1.1.

Limit

Frequency range(MHz)

Electric field strength(V/m)

Magnetic field

Power

Averaging

strength(A/m) density(mW/cm2) time(minutes)

(A) Limits for Occupational/Controlled Exposure

0.3-3.0

614

1.63

*100

6

3.0-30

1842/f

4.89/f

*900/f2

6

30-300

61.4

0.163

1.0 6

6

300-1500

/

/

f/300

6

1500-100000

/

/

5

6

(B) Limits for General Population/Uncontrolled Exposure

0.3-1.34

614

1.63

*100

30

1.34-30

824/f

2.19/f

*180/f2

30

30-300

27.5

0.073

0.2

30

300-1500

/

/

f/1500

30

1500-100000

/

/

1

30

f = frequency in MHz * = Plane-wave equivalent power density

4.1.2.

Test Procedures

E and H-field measurements should be made with the center of the probe at a distance of 20 cm surrounding the device and 20 cm above the top surface of the primary/client pair. These measurements should be repeated for three different client battery levels, 1%, 50%, and 99%. Record the test results. KDB 680106 D01 Wireless Power Transfer v04 (1) The power transfer frequency is below 1 MHz. (2) The output power from each transmitting element (e.g., coil) is less than or equal to 15 watts. (3) A client device providing the maximum permitted load is placed in physical contact with the transmitter(i.e., the surfaces of the transmitter and client device enclosures need to be in physical contact) (4) Only § 2.1091-Mobile exposure conditions apply (i.e., this provision does not cover § 2.1093-Portable exposure conditions). (5) The E-field and H-field strengths, at and beyond 20 cm surrounding the device surface, are demonstrated to be less than 50% of the applicable MPE limit, per KDB 447498, Table 1. These measurements shall be taken along the principal axes of the device, with one axis oriented along the direction of the estimated maximum field strength, and for three points per axis or until a 1/d (inverse distance from the emitter structure) field strength decay is observed. Symmetry considerations may be used for test reduction purposes. The device shall be operated in documented worst-case compliance scenarios (i.e., the ones that lead to the maximum field components), and while all the radiating structures (e.g., coils or antennas) that by design can simultaneously transmit are energized at their nominal maximum power. (6) For systems with more than one radiating structure, the conditions specified in (5) must be met when the system is fully loaded (i.e., clients absorbing maximum power available), and with all the radiating structures operating at maximum power at the same time, as per design conditions. If the

Add:Room 102, 201, Building 2, Yuanwanggu RFID Industrial Park, Tongguan Road, Tianliao Community, Yutang Street, Guangming District, Shenzhen,China

Tel: (86-755) 29989321

Fax: (86-755) 29985110

Web:www.sz-hongbiao.com

- Page 10 of 12 -

Report No.: HB20240813005E-02

design allows one or more radiating structures to be powered at a higher level while other radiating structures are not powered, then those cases must be tested as well. For instance, a device may use three RF coils powered at 5 W, or one coil powered at 15 W: in this case, both scenarios shall be tested.

4.1.3.

Equipment Approval Considerations item 5 b) of KDB 680106 D01 Wireless

Power Transfer v04

Requirement

Device

Yes. The operating frequencies are:

1. Power transfer frequency is less than 4 MHz.

Watch: 320kHz Phone: 115kHz~205kHz

TWS: 115kHz~205kHz

Yes. The maximum output power is:

2. Output power from each primary coil is less Wireless Output (Phone): 15W (Max)

than or equal to 15 watts

Wireless Output (TWS): 5W (Max)

Wireless Output (Watch): 3W (Max)

3. The system may consist of more than one

source primary coils, charging one or more

clients. If more than one primary coil is present, Yes. The EUT has three source primary coils.

the coil pairs may be powered on at the same

time.

4. Client device is placed directly in contact with Yes. The client device is placed directly in

the transmitter.

contact with the transmitter.

5. Mobile exposure conditions only (portable

exposure conditions are not covered by this

Yes. Mobile exposure conditions only.

exclusion).

6. The aggregate H-field strengths anywhere at

or beyond 20 cm surrounding the device, and 20

cm away from the surface from all coils that by

design can simultaneously transmit, and while Yes. See the test result in item 4.1.5

those coils are simultaneously energized, are

demonstrated to be less than 50% of the

applicable MPE limit.

4.1.4.

Test Setup

Top Side

Back Side

Left Side

20cm Right Side

EHP 200A Probe

Front Side

Add:Room 102, 201, Building 2, Yuanwanggu RFID Industrial Park, Tongguan Road, Tianliao Community, Yutang Street, Guangming District, Shenzhen,China

Tel: (86-755) 29989321

Fax: (86-755) 29985110

Web:www.sz-hongbiao.com

- Page 11 of 12 -

Report No.: HB20240813005E-02

4.1.5.

Test Result

Test condition: Mode 4 operating mode with client device (1 %, 50%, 99% battery status of client device) -test distance: 20cm

Maximum permissible Exposure

Battery levels <1% <1% <1% <1% <1%

Test sides
Top Left Right Front Back

Test distance(cm)
20 20 20 20 20

E ­field(V/m)
4.9679 2.5141 0.7739 3.2236 1.8110

H­field(A/m)
0.1339 0.0806 0.0454 0.0898 0.0688

Limit

614

1.63

Margin Limit (%)

0.81%

8.21%

Battery levels <50% <50% <50% <50% <50%

Maximum permissible Exposure

Test sides
Top Left Right Front Back

Test distance(cm)
20 20 20 20 20

E ­field(V/m)
4.7021 2.5037 0.7612 3.2123 1.8092

Limit

614

H­field(A/m)
0.1201 0.0708 0.0421 0.0822 0.0612
1.63

Margin Limit (%)

0.77%

7.37%

Battery levels <99% <99% <99% <99% <99%

Maximum permissible Exposure

Test sides
Top Left Right Front Back

Test distance(cm)
20 20 20 20 20

E ­field(V/m)
4.5041 2.3022 0.7322 3.1020 1.7123

Limit

614

H­field(A/m)
0.1103 0.0451 0.0333 0.0451 0.0398
1.63

Margin Limit (%)

0.73%

6.77%

Add:Room 102, 201, Building 2, Yuanwanggu RFID Industrial Park, Tongguan Road, Tianliao Community, Yutang Street, Guangming District, Shenzhen,China

Tel: (86-755) 29989321

Fax: (86-755) 29985110

Web:www.sz-hongbiao.com

- Page 12 of 12 -
5 Photographs of the Test Setup
MPE

Report No.: HB20240813005E-02

****** END OF REPORT ******

Add:Room 102, 201, Building 2, Yuanwanggu RFID Industrial Park, Tongguan Road, Tianliao Community, Yutang Street, Guangming District, Shenzhen,China

Tel: (86-755) 29989321

Fax: (86-755) 29985110

Web:www.sz-hongbiao.com



Related FCC IDs: