RFXtrx User Guide
ROBB
RFXtrx User Guide - ROBBshop
Copyright 2011-2017, RFXCOM
PDF RFXtrx User Guide - ROBBshop
RFXtrx User Guide
User guide. www.rfxcom.com. Copyright 2011-2017, RFXCOM. ... Note: sudo must be entered without brackets [ ]. sudo is required if not running as super user View
Not Your Device? Search For Manuals or Datasheets below:
File Info : application/pdf, 50 Pages, 975.67KB
Document DEVICE REPORTrfxtrx user guide-2 58248295RFXtrx USB RF transceiver User guide www.rfxcom.com Copyright 2011-2017, RFXCOM RFXtrx Version 5.37 page 1 / 50 1. Table of Contents 1. Table of Contents ................................................................................................................ 2 2. RFXtrx general information.................................................................................................. 3 2.1. RFXtrx315 supported protocols .................................................................................... 3 2.1.1. RFXtrx315 configured for 310MHz ........................................................................ 3 2.1.2. RFXtrx315 configured for 315MHz ........................................................................ 3 2.1.3. RFXtrx868X .......................................................................................................... 3 2.2. RFXrec433, RFXtrx433, RFXtrx433E supported protocols ........................................... 4 2.2.1. By function ............................................................................................................ 4 2.2.2. Alphabetic list ........................................................................................................ 8 2.3. undec on .................................................................................................................... 14 2.4. Sensitivity influenced by enabled protocols ................................................................ 15 2.5. RF range reduction..................................................................................................... 16 2.6. Home Automation software ........................................................................................ 16 2.7. Dimensions ................................................................................................................ 16 2.8. Electrical .................................................................................................................... 16 2.9. Environmental conditions ........................................................................................... 16 3. Install the USB driver......................................................................................................... 17 4. Run RFXflash on Linux under Mono.................................................................................. 17 5. RFXmngr test program ...................................................................................................... 18 5.1. Receiver ..................................................................................................................... 19 5.2. Transmitter ................................................................................................................. 20 6. Flash update of the RFXtrx................................................................................................ 21 6.1. Update firmware in the RFXtrx ................................................................................... 21 6.2. Update firmware in the RFXtrx step by step ............................................................... 22 7. RFXtrx433 special device codes ....................................................................................... 24 7.1. Remote commands .................................................................................................... 24 7.1.1. X10 RF Remote .................................................................................................. 24 7.1.2. ATI Remote Wonder............................................................................................ 25 7.1.3. ATI Remote Wonder Plus.................................................................................... 26 7.1.4. Medion Remote................................................................................................... 27 7.2. Harrison address conversion to switch settings .......................................................... 28 7.3. Flamingo, AB400, IMPULS, Sartano, Brennenstuhl, SilverCrest 91089, Cranenbroek switch settings ...................................................................................................................... 29 7.4. Energenie 5-gang 429.950 ......................................................................................... 30 7.5. Phenix, IDK YC-4000S switch settings ....................................................................... 31 7.6. HE105 switch settings ................................................................................................ 32 7.7. HQ COCO-20............................................................................................................. 33 7.8. MDREMOTE V106, V107........................................................................................... 34 7.9. MDREMOTE V108, EKAB-10KRF ............................................................................. 34 7.10. Aoke relay............................................................................................................... 34 7.11. SEAV TXS4 ............................................................................................................ 35 7.12. How to find the dx.com RGB LED strip driver ID ..................................................... 35 7.13. How to find the dx.com RGB LED strip driver ID (rev. 2)......................................... 35 7.14. How to find the Eurodomest ID ............................................................................... 35 7.15. How to find the Screenline ID.................................................................................. 36 7.16. How to find the Avantek remote ID.......................................................................... 36 8. Blyss commands ............................................................................................................... 37 9. Somfy RTS........................................................................................................................ 37 10. BlindsT6......................................................................................................................... 38 10.1. Dooya DT82TV, DT82TN....................................................................................... 38 11. Lucci Air fan ................................................................................................................... 38 12. Transmit undecoded ARC commands. .......................................................................... 39 13. MCZ pellet stove............................................................................................................ 40 14. Known Lighting4 devices ............................................................................................... 41 14.1. Proluxx projection screen........................................................................................ 41 14.2. Kingpin (KP100) projection screen.......................................................................... 41 14.3. Mercury remote control mains sockets.................................................................... 41 Copyright 2011-2017, RFXCOM RFXtrx Version 5.37 page 2 / 50 14.4. Conrad 034911 sockets .......................................................................................... 41 15. FAQ ............................................................................................................................... 42 15.1. Receive has stopped suddenly but transmit works.................................................. 42 15.2. Can I increase the receive/transmit range of the RFXtrx? ....................................... 42 15.3. The RFXtrx USB connection disconnects sometimes. ............................................ 42 15.4. I have a 433.92MHz sensor/remote but this device is not received. ........................ 42 15.5. The wall plug is switched by the remote. The remote is received but the RFXtrx does not switch the module. .......................................................................................................... 42 16. EC Declaration of Conformity......................................................................................... 43 17. Warning: ........................................................................................................................ 44 18. License .......................................................................................................................... 44 19. Copyright notice............................................................................................................. 44 20. Revision history ............................................................................................................. 45 2. RFXtrx general information The RFXtrx transceivers and RFXrec receivers are communicating over an USB port with the Home Automation application. The RFXtrx/rec is powered by the USB port. At startup the RFXtrx enters for 2 seconds the boot loader (red LED is on) and after this it starts the receive/transmit firmware. If valid (decode-able) packets are received the yellow LED will blink. The RFXtrx315 and the RFXrec433 are mainly for use in the US. The RFXtrx315 can receive US X10 lighting and security sensors or US Visonic PowerCode sensors at 315MHz. The RFXrec433 can receive weather sensors of different brands at 433.92MHz. The RFXtrx433 is a transceiver (transmitter+receiver) and can receive and control a large number of sensors and other devices. The RFXtrx433E is an extended RFXtrx433 transceiver. Note: the listed protocols and brands are supported! 2.1. RFXtrx315 supported protocols 2.1.1. RFXtrx315 configured for 310MHz US X10 lighting US X10 security Protocol Protocol receive transmit X10 Y Y X10 Y Y 2.1.2. RFXtrx315 configured for 315MHz Protocol Aoke relay - http://www.aliexpress.com/store/product/whose-sale-prices-DC12V10A-Learning- Code-Wireless-Remote-Control-Switch-System-1-Receiver-and-1Transmitter/1211856_1774391429.html PT2262, EV1527 and compatibles Keeloq (unencrypted part only) Visonic CodeSecure (unencrypted part only) Visonic PowerCode Protocol receive transmit Lighting5 - Y Lighting4 Y Y Keeloq Y - Visonic Y - Visonic Y Y 2.1.3. RFXtrx868X Protocol FS20 Itho CVE RFT Keeloq (unencrypted part only) Visonic CodeSecure (unencrypted part only) Visonic PowerCode Protocol Keeloq Visonic Visonic receive Y Y Y Y transmit Y Y Y - Copyright 2011-2017, RFXCOM RFXtrx Version 5.37 page 3 / 50 2.2. RFXrec433, RFXtrx433, RFXtrx433E supported protocols 2.2.1. By function Curtains, shades, projection screen, awning, gate openers A-OK blind motors (RF01,AC114,AC123 controlled) - http://www.motorisationplus.com/ ASA ETR blind motors - http://www.asa-mingardi.org/en/home.php ASP blind motors - http://www.asp-distribution.com/site%20volet/voletrenovation.aspx BOFU blind motors - http://www.bofumotor.com/ BTX blind motors, remote, part# 490.2076 http://www.btxinc.com Brel blind motors - http://www.brel-motors.nl/webshop/motoren/ Chamberlain CS4330CN http://www.chamberlain24.de/epages/es122868.sf/en_GB/?ObjectPath=/Shops/es122868/Products/RA4336 Confexx CNF24-2435 Dolat DLM-1 controlled motors - http://www.dolat.com.cn/product1.asp?id=538 Dooya blind motors, remotes tested: DC305,DC306,DC307,DC313,DC1650,DC1651 Ematronic - http://www.ematronic.com/moteurs-volet-roulant/ ESMO blind motors Forest blind/curtain motors - http://www.forestgroup.nl/index_nl.html Harrison curtain http://www.harrison.nl/home2.htm Hasta blind motors - http://www.hasta.se/ JVS screens - http://www.screen-discount.nl/ Kingpin KP100 projection screen Louvolite one touch motorised blinds Luxaflex (RFXtrx433E only) - http://www.luxaflex.se/produkter/luxaflex/rullgardiner/ Media Mount Projector screen Motolux - http://www.motolux.com.au/ Outlook Motion Blinds - https://www.spotlightstores.com/curtains-blinds/indoor-blinds/roller-blinds/project-outlook-motion-motorised- roller-blind/p/BP80360543 Proluxx projection screen Quotidom - http://www.quotidom.com/moteur-tubulaire-radio-quotidom-10-ou-20-nm-volet-roulant-ou-store-banne.html RAEX blind motor (YR1326 controlled) RohrMotor24 RMF blind motors - http://www.rohrmotor24.eu/rohrmotor24 RollerTrol blind motors - http://rollertrol.com/ Screenline motors - http://www.screenline.cz/en/ Silverline Premium - http://www.aluparts.nl Simu (RFXtrx433E only) http://www.simu.com/ Somfy (RFXtrx433E only) http://www.somfy.co.uk/ Sunpery blind motors YOODA blind motors http://www.sukcesgroup.pl Copyright 2011-2017, RFXCOM RFXtrx Version 5.37 page 4 / 50 Temperature, humidity, weather sensors Alecto WSD10,WS1200, WS1700, WS3500, WS4500 Auriol H13726 Ambient Weather - F007TH Banggood SKU174397 http://www.banggood.com/433MHz-Wireless-Weather-Station-Digital-Thermometer-Humidity-Sensor-p-965559.html Blyss 630467 Cresta Digimax Froggit - F007TH Hama EWS1500 Hideki weather sensors Honeywell TF-ATS34C Inovalley SM80 with plant probes - http://www.inovalley.com/detail.php?item_id=289 La Crosse Lexibook SM883 Marquant 943134 Maverick ET-732, ET-733 BBQ/Smoke temperature Meade TS33F-M, TS34C-M http://www.meade.com/products/weatherstations/sensors.html Meteoscan W155, W160 NEXUS I008T mi.sol WH2 http://www.ebay.com/itm/Transmitter-for-Wireless-Weather-Station-wireless-temperature-sensor-/121664060899 Opus XT300 /Imagintronix Soil sensor http://www.plantcaretools.com/en/webshop/wireless-moisture-sensor-en-detail http://www.ebay.co.uk/itm/Wireless-Soil-Moisture-Sensor/251380900939?pt=UK_Home_Garden_Garden_Plants_Fertiliser_CV&hash=item3a8778244b Oregon Scientific / Huger Pearl NC-7159 http://www.pearl.de/a-NC7159-3041.shtml Prego P-8426 http://www.sunmarket.fi/tuote.asp?TID=11990 Proove TSS320 & TSS330 fridge/freezer thermometer & outdoor sensors 311346,311501 RFXSensor RUBiCSON stektermometer 48659, 48695 -pool sensor p48019 Sunvic TLX1206 Sunvic TLX7506 TechnoLine/Proficell http://www.elv.de/output/controller.aspx?cid=74&detail=10&detail2=27621 - TX95-TH TFA UPM/Esic (very short receiving range) Ventus WS155 Viking WT0122 pool thermometer Xiron EN6 Door/window, smoke and other security sensors Aidebao security Alecto SA30, SA33 smoke detector AliExpress sensors with EV1572 or PT2262 (PT2262 is preferred) Atlantic security Chacon KD101 smoke detector Chuango security Eminent security Flamingo KD101 smoke detector FA20RF, FA21RF Focus Housegard Origo smoke detector Kerui security Meiantech security NEXA KD101 smoke detector Renkforce RF101 smoke detector Copyright 2011-2017, RFXCOM RFXtrx Version 5.37 page 5 / 50 Smartwares RM174RF smoke detector Oregon MSR939 https://www.redealer.de/multimedia/home-living/wetterstationen/bewegungssensor-msr939/a-200667/ Visonic CodeSecure Visonic PowerCode X10 security Appliance modules, dimmers, relays, LED controllers ANSLUT (learning mode) Aoke relay http://www.aliexpress.com/store/product/whose-sale-prices-DC12V10A-Learning-Code-Wireless-Remote-Control-Switch- System-1-Receiver-and-1-Transmitter/1211856_1774391429.html Avantek ByeByeStandBy Blyss lighting http://www.castorama.fr/store/Prise-telecommandee-et-telecommande-BLYSS---Interieur-prod4470026.html Brennenstuhl Chacon http://www.chacon.be/ CoCo http://www.coco-technology.com/en/home/ Conrad RSL2 http://www.conrad.com/ce/en/product/640466/FUNK-STECKDOSENSCHALTER-RSLR2 Cotech Smarthome Cranenbroek DI.O http://www.di-o.be/ DomiaLite Ebode ELRO AB400/AB600 http://www.elro.eu/en/products/cat/home-automation/home-control1 Energenie ENER010 429.935, 5-gang 429.950 - https://energenie4u.co.uk/ Etekcity http://etekcity.com/p-300-5-pack-wireless-remote-control-outlet-switch-set-with-2-remote-controls-zap-5lx.aspx Eurodomest NL Action Everflourish EMW100 Flamingo Flamingo FA500D FA500DSS Flamingo Smartwares SF501 Home Confort http://www.home-confort.net/en HomeEasy EU http://www.elro.eu/en/products/cat/home-automation/ HomeEasy UK (including HE105 relay) http://www.homeeasy.eu/ HQ COCO-20 Ikea Koppla Impuls NL Action Intertechno http://www.intertechno.at/ Kambrook RF3672 http://www.bunnings.com.au/kambrook-4-piece-indoor-powerpoint-kit-with-remote-control_p7030054 KlikAanKlikUit http://www.klikaanklikuit.nl/home/ Legrand CAD radio http://docdif.fr.grpleg.com/general/legrand-fr/NP-FT-GT/FA181DFR.pdf LightwaveRF http://www.lightwaverf.co.uk/ Livolo - http://www.livolo-france.com/fr/ http://nl.aliexpress.com/w/wholesale-livolo-touch-switch.html Maplin http://www.maplin.co.uk/p/remote-controlled-mains-socket-set-single-n78ka (use Lighting1 COCO GDR2) MDremote LED dimmer V106, V107, V108, EKAB-10KRF - www.ultraleds.co.uk - http://www.ledstripkoning.nl/accessoires/dimmers-wit/draadloze-dimmer-10-knops-rf/ Mercury appliance modules http://mercury.avsl.com/product?range=ME5124 NEXA http://www.nexa.se/ ORNO OTIO Phenix Philips SBC SP370 series PROmax Proove - http://proove.se/ Quigg RGB LED strip driver dx.com - http://www.dx.com/ order nbr: 130913 (new TRC02 not supported) , 67412 RisingSun Sartano Copyright 2011-2017, RFXCOM RFXtrx Version 5.37 page 6 / 50 Siemens (UK) SilverCrest 91089 SilverCrest 60494 Unitec 48110 EIM 826 Waveman X10 RTS10 / RFS10 X10 lighting Xdom ATI Remote Wonder ATI Remote Wonder Plus ATI Remote Wonder II SEAV TXS4 X10 PC Remote Remotes Chimes 1byOne Easy Chime Byron SX chime - http://www.chbyron.eu/Byron/ByronSXRange/68/89/ Byron MP001 Chacon Envivo ENV1348 HomeEasy KlikAanKlikUit Profiles PAC-326R Belcanto SelectPlus200689101 & SelectPlus200689103 (Action NL) Power, gas water metering Cartelectronic TIC and Encoder - https://www.cartelectronic.fr/index.php?id_product=124&controller=product cent-a-meter Electrisave OTIO EHS5050 OWL CM113, CM180, CM119, CM160, CM180, CM180i - http://www.theowl.com/ Revolt NC5461 - http://www.pearl.de/a-NC5462-5452.shtml RFXMeter Specials 1byone Wireless Home Security Driveway Alarm http://www.1byone.co.uk/Home-Security/Alarms/O00QH-0511 DEA receivers http://www.deasystem.com/en/accessory/7/receivers (unencrypted only) Lucci Air Fan - http://www.lucciair.com/ MCZ pellet stove Mertik Maxitrol Fire Place controllers Oregon Scientific Body weight scales BWR101, BWR102, GR101 Prego P-8426 sauna temperature sensor http://www.sunmarket.fi/tuote.asp?TID=11990 Smartwares radiator valve http://www.homewizard.nl/smartwares-draadloze-radiatorkraan.html Siemens SF01 - LF959RA50/LF259RB50/LF959RB50 extractor hood Wave Design extractor hood X10 Ninja/Robocam camera motor Copyright 2011-2017, RFXCOM RFXtrx Version 5.37 page 7 / 50 2.2.2. Alphabetic list Important notes: - Ext and Ext2 firmware will not operate in the RFXtrx433. - RFXrec firmware is equal to RFXtrx433 Type1 firmware without the transmit functions. - Protocol enabling is only necessary for receive. Transmit protocols are always enabled. Device Type 1 Type 2 Ext Ext2 1byone Driveway Alarm - http://www.1byone.co.uk/Home-Security/Alarms/O00QH- - Y Y Y 0511 1byone Easy Chime - Y Y Y A-OK blind motors RF01 - http://www.motorisationplus.com/ A-OK blind motors AC114,AC123 - http://www.motorisationplus.com/ Aidebao security Y Y-Y Y Y-Y Y YYY Alecto SA30, SA33 smoke detector Y - Y - Alecto WS1200 Alecto WS1700 and compatibles, WS3500, WS4500 Y YYY - - YY Alecto WSD10 Ambient Weather - F007TH ANSLUT (learning mode) - - -Y - - -Y Y YYY Aoke relay - http://www.aliexpress.com/store/product/whose-sale- prices-DC12V10A-Learning-Code-Wireless-Remote-Control- Y Switch-System-1-Receiver-and-1- Transmitter/1211856_1774391429.html ASA ETR blind motors - http://www.asa-mingardi.org/en/home.php - ASP blind motors - http://www.asp- distribution.com/site%20volet/voletrenovation.aspx Y ATI Remote Wonder Y Y Y Y - YY Y - Y - - - ATI Remote Wonder Plus Y - - - ATI Remote Wonder II (only available in hardware version 1.0) Atlantic security Y - - - Y YYY Auriol H13726 - - YY Auriol Z31055B-TX - - -Y Avantek - - YY Banggood SKU174397 - ByeByeStandBy Y Byron SX chime - http://www.chbyron.eu/Byron/ByronSXRange/68/89/ Y Byron MP001 chime - Blyss lighting - http://www.castorama.fr/store/Prise-telecommandee-et- Y telecommande-BLYSS---Interieur-prod4470026.html Blyss temperature/humidity 630467 Y BOFU blind motors - http://www.bofumotor.com/ Y * = receive only in Type2 used to get the remote ID. Brennenstuhl Y Brel blind motors http://www.brel- Y motors.nl/webshop/motoren/ BTX blind motors, remote, part# 490.2076 - http://www.btxinc.com - Cartelectronic TIC and Encoder https://www.cartelectronic.fr/index.php?id_product=124&cont - roller=product cent-a-meter Y Chacon (learning mode) Y - YY Y Y Y Y Y Y - YY YY - Y - - Y Y Y Y Y Y Y Y Y Y- - Y - Y YY Y Y Y Copyright 2011-2017, RFXCOM RFXtrx Version 5.37 Protocol ByronSX ByronSX BlindsT2 BlindsT3 Meiantech Oregon LaCrosse Rubicson Rubicson Oregon AC Lighting5 Aoke or Lighting1 ARC rec xmit Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y N Y RFY BlindsT11 ATI ATI ATI Meiantech Rubicson Rubicson Lighting5 *Lighting4 Rubicson ARC ByronSX Chime Byron MP001 AE AE BlindsT0 Lighting4 BlindsT6 BlindsT9 N Y Y Y Y Y Y Y Y Y Y Y Y Y* Y Y Y Y Y Y N Y Y Y Y - Y* Y Y Y N Y N Y ATI/cartelectronic Y N Oregon AC Y Y Y page 8 / 50 - http://www.chacon.be/ Chacon (with address code wheels) Y YYY ARC Y Y Chacon EMW200 Chacon 54660 (equal COCO GDR2) Y YY Y YYY Lighting1 EMW200 Lighting1 COCO GDR2 N Y N Y Chacon KD101 smoke detector Y YYY always on Y Y Chamberlain CS4330CN http://www.chamberlain24.de/epages/es122868.sf/en_GB/? - ObjectPath=/Shops/es122868/Products/RA4336 - Y - BlindsT8 N Y Chuango * decoded as X10 in Ext2 firmware Y Y Y Y* Lighting4 Y Y CoCo (learning mode) - http://www.coco-technology.com/en/home/ Y YYY AC Y Y CoCo (with address code wheels) Y YYY ARC Y Y CoCo GDR2 (equal Chacon 54660) Y YYY Lighting1 COCO GDR2 N Y Confexx CNF24-2435 - - -Y BlindsT12 N Y Conrad RSL2 - http://www.conrad.com/ce/en/product/640466/FUNKSTECKDOSENSCHALTER-RSLR2 Y Y-Y RSL Y Y Conrad RSL sensors - Y - - RSL Y Y Conrad RSL2 motion/door-window sensors - Y - - RSL Y Y Cotech Smarthome - - -Y Lighting4 + AC Y Y Cranenbroek Y YYY Lighting1 Impuls N Y Cresta - TX-320, TS34C, anemometer, UV sensor, rain sensor Y YYY Hideki Y - DEA receivers (unencrypted) http://www.deasystem.com/en/accessory/7/receivers - - Y - KeeLoq Y Y Digimax Y YY - X10 Y - DI.O (learning mode) - http://www.di-o.be/ Y YYY AC Y Y DI.O (with address code wheels) Y YYY ARC Y Y Dolat DLM-1 controlled motors - http://www.dolat.com.cn/product1.asp?id=538 - Y - - BlindsT10 N Y DomiaLite (with address code wheels) Y YYY ARC Y Y Dooya blind motors, emulate remotes: DC305,DC306,DC307,DC313,DC1650,DC1651 Y YYY BlindsT6 N Y Ebode Y YYY X10 Y Y Electrisave Y YY - Oregon Y - ELRO AB400 - http://www.elro.eu/en/products/cat/home-automation/home- Y Y Y - control1 Lighting4 Y Y ELRO AB600 Y YYY ARC Y Y Ematronic RF01 - http://www.ematronic.com/moteurs-volet-roulant/ Y Y-Y BlindsT2 Y Y Ematronic AC114, AC123 - http://www.ematronic.com/moteurs-volet-roulant/ Y Y-Y BlindsT3 Y Y Eminent * decoded as X10 in ext firmware Y Y Y Y* Lighting4 Y Y Energenie - https://energenie4u.co.uk/ - ENER010 429.935, 5-gang 429.950 Envivo Chime ENV1348 Y Y Y - Lighting1 Energenie Energenie5 N Y - - Y - Chime Envivo N Y ESMO blind motors Y YYY BlindsT6 N Y Etekcity http://etekcity.com/p-300-5-pack-wireless- remote-control-outlet-switch-set-with-2-remote-controls-zap- Y Y Y - 5lx.aspx Lighting1 Energenie5 N Y Eurodomest (NL Action) * ARC only Y* Y Y* Y* Lighting1 ARC Or N Y Lighting5 Eurodomest Everflourish EMW100 Y Y Y - Lighting5 EMW100 N Y Flamingo Y YYY Lighting4 Y Y Flamingo FA500D FA500DSS - - -Y IT N Y Copyright 2011-2017, RFXCOM RFXtrx Version 5.37 page 9 / 50 Flamingo KD101 smoke detector FA20RF, FA21RF Y YYY always on Y Y Flamingo Smartwares SF501 Y Y Y Y Lighting2 - AC Y Y Focus Y YYY Meiantech Y Y Forest blind/curtain motors - http://www.forestgroup.nl/index_nl.html Y YYY BlindsT7 N Y Froggit - F007TH - - -Y Oregon Y - HAMA EWS1500 - - YY Rubicson Y - Harrison curtain - http://www.harrison.nl/home2.htm Y YYY Curtain Harrison N Y Hasta new blind motors - http://www.hasta.se/ Y YYY BlindsT0 Y* Y * = receive only in Type2 used to get the remote ID. Hasta old blind motors YY- - BlindsT1 Y Y Hideki weather sensors Y YYY Hideki Y - Home Confort lighting - http://www.home-confort.net/en - - Y - HomeConfort Y Y HomeEasy EU (learning mode) - http://www.elro.eu/en/products/cat/home-automation/ Y YYY HE EU Y Y HomeEasy UK HE105 - http://www.homeeasy.eu/ Y Y Y Y Thermostat2 HE105 N Y HomeEasy UK (learning mode) Y YYY AC Y Y HomeEasy UK (with address code wheels) Y Y Y Y ARC Y Y Honeywell - TF-ATS34C Y YYY Hideki Y - Housegard Origo smoke detector - - -Y ARC Y Y HQ COCO-20 - - YY Lighting1 HQ COCO20 N Y Ikea Koppla Y - - - Lighting3 N Y Impuls (NL Action) Y YYY Lighting1 Impuls N Y Inovalley SM80 with plant probes - http://www.inovalley.com/detail.php?item_id=289 - - YY Rubicson Y - Intertechno (learning mode) - http://www.intertechno.at/ Y YYY AC Y Y Intertechno (with address code wheels) Y YYY ARC Y Y JVS screens - http://www.screen-discount.nl/ Y YYY BlindsT6 N Y Kambrook RF3672 http://www.bunnings.com.au/kambrook-4-piece-indoorpowerpoint-kit-with-remote-control_p7030054 - YY - Lighting2 Kambrook N Y Kerui security * decoded as X10 in Ext2 firmware Y Y Y Y* Lighting4 Y Y Kingpin KP100 projection screen Y YYY Lighting4 N Y KlikAanKlikUit (learning mode) - http://www.klikaanklikuit.nl/home/ Y YYY AC Y Y KlikAanKlikUit (with address code wheels) Y YYY ARC Y Y La Crosse - TX2, TX3, TX3P, TX4, TX7, TX17, WS2300 Y YYY LaCrosse Y - Legrand CAD radio - - Y - Lighting5 LeGrand CAD - Y Lexibook - SM883 Y YYY Hideki Y - LightwaveRF - http://www.lightwaverf.co.uk/ Y YYY AD Y Y Livolo - http ://www.livolonederland.nl/ - http://www.livolo-France.com/fr/ Y YYY Lighting5 Livolo N Y - http://nl.aliexpress.com/w/wholesale-livolo-touch- switch.html Louvolite one touch motorised blinds * = receive only in Type2 used to get the remote ID. Y YYY BlindsT0 Y* Y Lucci Air fan http://www.lucciair.com/ - - Y - Fan LucciAir N Y Luxaflex http://www.luxaflex.se/produkter/luxaflex/rullgardiner/ - - YY RFY N Y Maplin http://www.maplin.co.uk/p/remote-controlled- mains-socket-set-single-n78ka Y YYY Lighting1 COCO GDR2 N Y Copyright 2011-2017, RFXCOM RFXtrx Version 5.37 page 10 / 50 Marquant 943134 - Maverick ET-732/733 BBQ/Smoke temperature Y MCZ pellet stove - MDremote LED dimmer V106 - www.ultraleds.co.uk Y MDremote LED dimmer V107 - www.ultraleds.co.uk Y MDremote LED dimmer V108, EKAB-10KRF - http://www.ledstripkoning.nl/accessoires/dimmers- Y wit/draadloze-dimmer-10-knops-rf/ Meade TS33F-M, TS34C-M http://www.meade.com/products/weatherstations/sensors.ht Y ml Media Mount Projector screen - Meiantech security Y Mercury appliance modules - http://mercury.avsl.com/product?range=ME5124 Y Mertik Maxitrol Fire Place controllers - G6R-H4T1, G6R-H4T5, G6R-H4TD, G6R-H4T16, G6R- Y H4TB, G6R-H4T21-Z22 Mertik Maxitrol Fire Place controller - G6R-H4S Y Meteoscan W155,W160 - Motorlux blinds motor Y mi.sol WH2 http://www.ebay.com/itm/Transmitter-for- Wireless-Weather-Station-wireless-temperature-sensor- Y /121664060899 NEXA (learning mode) - http://www.nexa.se/ Y NEXA (with address code wheels) Y NEXA KD101 smoke detector Y NEXUS - I008T Y Opus XT300 /Imagintronix Soil sensor http://www.plantcaretools.com/en/webshop/wireless- moisture-sensor-en-detail http://www.ebay.co.uk/itm/Wireless-Soil-Moisture-Sensor- Y /251380900939?pt=UK_Home_Garden_Garden_Plants_Fert iliser_CV&hash=item3a8778244b ORNO Y Oregon Scientific / Huger BBQ and weather sensors - AW129, AW131, BTHGN129, BTHR918, BTHR918N, BTHR968, EW109, PCR800, RGR126, RGR682, RGR918, RGR928, RTGN318, RTGR328N, RTGR328N, RTGR368N, RTGR383, RTHN318, STR918, STR928, ,THGN800, THGN801, THC138, THC238, THC268, THGN122NX, THGN123N, THGN132ES, THGN132N, THGN500, Y THGR122(N/NX), THGR228(N/NF), THGR238, THGR268, THGR328N, THGR810, THGR918, THGR928, THGRN228NX, THN122N, THN129, THN132N, THR128, THR138, THR288(N/NF), THRN122N, THWR288A, THWR800, UV138, UVN128, UVN800, UVR128, WGR800, WGR918, WTGR800, WTGR800 Oregon Scientific weighting scales - BWR101, BWR102, GR101 Y US BWR101, BWR102 in RFXrec Oregon MSR939 https://www.redealer.de/multimedia/home- - living/wetterstationen/bewegungssensor-msr939/a-200667/ OTIO EHS5050 - OTIO Lighting Y Outlook Motion Blinds - https://www.spotlightstores.com/curtains-blinds/indoorblinds/roller-blinds/project-outlook-motion-motorised-roller- - blind/p/BP80360543 OWL CM113 Y OWL - http://www.theowl.com/ Y Y- Y Y Y YY Y Y Y Y Y Y Y Y Y Y Y Y Y- Y Y Y Y Y Y Y Y Y Y Y Y - YY Y - Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y - YY - Y Y- Y - Y Y- YY Y Y Y Copyright 2011-2017, RFXCOM RFXtrx Version 5.37 X10 Y - Hideki Y - Thermostat4 - Y Lighting5 MDRemote V106 N Y Lighting5 MDRemote V107 N Y Lighting5 MDRemote V108 N Y Hideki Lighting4 Meiantech Lighting1 Energenie5 Mertik Y N Y Y Y N Y Y Y Mertik Rubicson BlindsT3 FineOffset N Y Y - Y Y - AC ARC always on Hideki Y Y Y Y Y Y Y - XT300 AC Y Y Y Oregon Y - Oregon Y - Oregon RSL RSL Y - Y Y Y BlindsT4 Y Y Oregon Oregon Y Y - page 11 / 50 - CM119, CM160, CM180, CM180i Pearl NC-7159 http://www.pearl.de/a-NC7159-3041.shtml - Phenix Y Philips SBC SP370 series - Prego P-8426 http://www.sunmarket.fi/tuote.asp?TID=11990 Y Profiles PAC-326R Belcanto Y Proluxx projection screen Y PROmax - Proove TSS320 & TSS330 fridge/freezer thermometer & outdoor sensors 311346,311501 Y Quigg RC DS5 4001-A DE 3726 - Quotidom http://www.quotidom.com/moteur-tubulaire- radio-quotidom-10-ou-20-nm-volet-roulant-ou-store- Y banne.html RAEX blind motor (YR1326 or YRL2016 controlled) - Renkforce RF101 smoke detector Y Revolt NC5461 - http://www.pearl.de/a-NC5462-5452.shtml - RFXSensor Y RFXMeter Y RGB LED strip driver dx.com - http://www.dx.com/ order nbr: 130913, (new TRC02 NOT supported) Y* - http://www.dx.com/ order nbr: 67412 * = receive only in Type2 used to get the RGB remote ID. RGB432W LED controller Y RisingSun Y RUBiCSON - stektermometer 48659, 48695 -pool sensor p48019 Y RohrMotor24 RMF blind motors - http://www.rohrmotor24.eu/rohrmotor24 Y RollerTrol blind motors - http://rollertrol.com/ Y * = receive only in Type2 used to get the remote ID. Sartano Y Screenline motors - http://www.screenline.cz/en/ - SEAV TXS4 - SelectPlus200689101 & SelectPlus200689103 - (Action NL) Siemens SF01 LF959RA50/LF259RB50/LF959RB50 - extractor hood Siemens (UK) Y SilverCrest 91089 Y SilverCrest 60494 - Silverline Premium - http://www.aluparts.nl Y Simu / RTS (RFXtrx433E only) http://www.simu.com/ - Smartwares radiator valve - http://www.homewizard.nl/smartwares-draadloze- - radiatorkraan.html Smartwares RM174RF - Somfy / RTS - http://www.somfy.co.uk/ To control Somfy Centralis use RFY2 commands. - Sunpery blind motors - Sunvic TLX1206 Y Sunvic TLX7506 Y TechnoLine/Proficell http://www.elv.de/output/controller.aspx?cid=74&detail=10&d etail2=27621 Y - TX95-TH TFA - TS15C, TS34C,external temperature sensor 30.3133, Y anemometer 30.3149, UV sensor, rain sensor 30.3148, pool - YY Rubicson Y - Y Y Y Lighting4 Y Y Y - - Lighting1 Philips SBC N Y YY - X10 Y - Y Y Y Y Y Y - -Y Y Y Y - -Y ByronSX Y Y Lighting4 N Y IT N Y FineOffset or Rubicson Y - Lighting4 + AC Y Y Y Y Y BlindsT6 N Y Y- Y Y Y Y- - Y Y Y Y Y Y BlindsT4 always on RSL X10 X10 Y Y Y Y Y - Y Y - Y Y* - AD Y* Y Y Y - Lighting5 RGB432W N Y Y Y Y Lighting4 Y Y - YY Rubicson Y - Y Y Y BlindsT6 N Y Y Y Y Y Y Y - -Y - -Y Y Y Y Y- Y Y Y YY - -Y Y Y Y - YY - YY - -Y - YY Y- YY YY - BlindsT0 Y* Y Lighting4 Y Y BlindsT13 N Y FAN SEAV TXS4 N Y ByronSX Y Y Fan SF01 AD Lighting4 Lighting4 + AC BlindsT6 RFY Radiator1 Smartwares ARC RFY BlindsT9 X10 X10 N Y Y Y Y Y Y Y N Y N Y N Y Y Y N Y N Y Y Y Y - - YY Rubicson Y - Y Y Y Hideki Y - Copyright 2011-2017, RFXCOM RFXtrx Version 5.37 page 12 / 50 sensor 30.3160 TFA - pool sensor 30.3056.10, 30.3216.20 TFA external temperature sensor 30.3208.02 UPM/Esic (very short receiving range) - WT260,WT260H,WT440H,WT450,WT450H,WDS500, RG700 Unitec 48110 EIM 826 Ventus WS155 Viking - 02035, 02038, 02811 Visonic CodeSecure Visonic PowerCode Wave Design extractor hood Waveman Westinghouse fan 7226640 WT0122 pool sensor YOODA blind motors - http://www.sukcesgroup.pl X10 Ninja/Robocam X10 PC Remote X10 RTS10 / RFS10 X10 lighting X10 security Xdom Xiron EN6 - - -Y - - -Y Oregon Hideki Y Y - Y - - - Hideki Y - - - -Y - - YY Lighting4 + AC Rubicson Y Y Y - Y YYY FineOffset Y - Y YYY Visonic Y - Y YYY Visonic Y - Y YYY Fan SF01 N Y Y Y Y Y Lighting1 Waveman N Y - - -Y Fan N Y - - Y - FineOffset Y - Y YYY BlindsT6 N Y - Y - - Y - - - Y YYY Y YYY Y YYY Y YYY Y - YY X10 X10 X10 X10 X10 X10 Rubicson Y Y Y Y Y Y Y Y Y Y Y Y Y - Copyright 2011-2017, RFXCOM RFXtrx Version 5.37 page 13 / 50 2.3. undec on This parameter is for internal use by RFXCOM only!!! If new sensor types are released they will most probably not be decoded by the RFXtrx firmware. For this reason we have added the option to enable receive of undecoded messages. This function is only to enable RFXCOM to add this new sensor type in the firmware if possible. If "undec on" is enabled in normal use the application will receive a lot of undecoded messages mostly as a result of RF noise or disturbed RF packets. Important: For normal use "undec on" should be disabled Copyright 2011-2017, RFXCOM RFXtrx Version 5.37 page 14 / 50 X10 ARC A C HomeEasy EU Meiantech/Atlantic Oregon 1.0 Oregon 2.1 Oregon 3.0 / OWL ATI Visonic/Keeloq Mertik AD (LWRF) Hideki/UPM La Crosse FS20 ProGuard BlindsT0 BlindsT1/T2/T3/T4 AE (Blyss) Rubicson/Alecto FineOffset/Viking Lighting4 RSL/Revolt Byron SX Imagintronix/Opus HomeConfort 2.4. Sensitivity influenced by enabled protocols The sensitivity of the receiver part is highly influenced by the number of protocols enabled. Lesser protocols enabled will make the receiver more sensitive for the enabled protocols. There are a few protocols that will reduce or even eliminate receiving of other protocols if enabled. For example: If the AD (LightwaveRF, Siemens) protocol is enabled it can stop receiving of Meiantech / Atlantic, Oregon 3.0,Visonic and Mertik. All other protocols are disabled if BlindsT0 is enabled. X10 ARC AC HomeEasy EU Meiantech/Atlantic Oregon ATI Visonic/Keeloq Mertik AD (LWRF) Hideki/UPM La Crosse FS20 ProGuard BlindsT0 BlindsT1/T2/T3 AE (Blyss) Rubicson FineOffset/Viking Lighting4 RSL Byron SX Imagintronix HomeConfort Green = enabled by default Copyright 2011-2017, RFXCOM RFXtrx Version 5.37 page 15 / 50 2.5. RF range reduction The RF signals operating distance is reduced when the signal has to pass through walls. 2.6. Home Automation software For the list of Home Automation software that supports the RFXtrx see the web site www.rfxcom.com 2.7. Dimensions The dimensions of the RFXtrx/RFXrec are: 83.5 x 42 x 15 mm Total height from bottom to antenna top is 122mm The dimensions of the RFXtrx433E are: 83 x 59 x 22 mm Total height from bottom to antenna top is 130mm 2.8. Electrical The RFXtrx is powered by the 5 Volt of the USB interface. Operating current; Receive mode: Transmit mode: 28 mA (0.14Watt) 45 mA The RFXtrx Radiated RF power is 10dBm max. 2.9. Environmental conditions Normal operating: Absolute min-max temperature: 15°C to 35°C -10°C to 55°C Copyright 2011-2017, RFXCOM RFXtrx Version 5.37 page 16 / 50 3. Install the USB driver The RFXtrx has the FTDI FT232R USB interface chip installed. The USB drivers are available at http://www.ftdichip.com/Drivers/VCP.htm 4. Run RFXflash on Linux under Mono Open a Terminal screen in Linux (Ctrl-Alt-T) Execute once: Install Mono: [sudo] apt-get install mono-runtime Install VisualBasic support under Mono: [sudo] apt-get install libmono-microsoft-visualbasic8.0-cil If the USB device is created as ttyACMx you will need to create a link between /dev/ttyACMx and a serial port /dev/ttySx. This is not necessary if the device is created as /dev/ttyUSBx !! [sudo] ln -sf /dev/ttyACM1 /dev/ttyS3 Note: sudo must be entered without brackets [ ]. sudo is required if not running as super user. Launch the RFXflash.exe program. [sudo] mono RFXflash.exe Note: RFXmngr does not operate under mono! Copyright 2011-2017, RFXCOM RFXtrx Version 5.37 page 17 / 50 5. RFXmngr test program The RFXmngr program supports decoding of received data and allows you to transmit commands. After the connection the RFXmngr program transmits a Reset and Get Status command so that it will know the RFXtrx type and configuration settings: Transmitter protocols are always enabled but receiver protocols can be disabled. This is very useful because the receiver will become more sensitive when protocols not used are disabled. So select only the protocols to be used, click Set mode and click Save Settings. Note that these settings are lost in Type1 and Type2 firmware after an update and need to be set again. Copyright 2011-2017, RFXCOM RFXtrx Version 5.37 page 18 / 50 5.1. Receiver The RF protocols to be received can be configured on the Main tab at Set Mode. Click Save Settings to save the selected protocols in non-volatile memory of the RFXtrx. This configuration is now restored every time after a power up. Note that these settings are lost after a firmware update and need to be set again. Note: Protocol enabling is only necessary for receive. Transmit protocols are always enabled. The received RF data is decoded and displayed in the yellow window. Copyright 2011-2017, RFXCOM RFXtrx Version 5.37 page 19 / 50 5.2. Transmitter The tabs after the Main tab are used to send commands to the transmitter. For example Lighting1 is used to send X10, ARC and some more. Note: Protocol enabling is only necessary for receive. Transmit protocols are always enabled. Select Type to see which protocols are supported on the different tabs. The transmitted commands are displayed in the yellow window including the acknowledge send by the RFXtrx, in the example above "ACK, data correct transmitted". Copyright 2011-2017, RFXCOM RFXtrx Version 5.37 page 20 / 50 6. Flash update of the RFXtrx 6.1. Update firmware in the RFXtrx Firmware is flashed in the RFXtrx using this procedure: 1. Depending on the RFXtrx type download the latest RFXtrx315_yy.hex, RFXrec433_yy.hex or RFXtrx433_yy.hex firmware file. 2. Connect the RFXtrx to a Windows system or Linux under MONO 3. Stop any program that is connected to the RFXtrx. 4. Start the RFXflash program (version 4.0.0.0 or higher) 5. Select the USB RFXtrx COM port or TCP/IP port and click the CONNECT button, (the red LED on the RFXtrx should switch on now) 6. Load the correct .hex firmware file for your RFXtrx, 7. Click the WRITE button, 8. Click the Normal Execution mode button. IMPORTANT: 1. Do not interrupt the flash procedure when started. 2. It can happen that the flash procedure ends with a pop-up screen indicating errors. Just disconnect the RFXtrx and start again at step 5 until the flash procedure if finished without errors. If the red LED does not switch on if you click the CONNECT button: 1. Check if you have selected the correct USB COM port. 2. If you have flashed the RFXtrx before and interrupted the flash procedure it is possible that the RFXtrx does not enter the flash state. Contact [email protected] for help. Note: Receiver Settings are lost in Type1 and Type2 firmware after an update and have to be set again. Copyright 2011-2017, RFXCOM RFXtrx Version 5.37 page 21 / 50 6.2. Update firmware in the RFXtrx step by step · Click the Connect to Device button. The RFXtrx will automatically switch from normal mode to the bootloader now. · Click the Open HEX file button and load the RFXtrxyyy_xx.hex file Be sure to load the latest firmware file for the RFXtrx. yyy indicates the RFXtrx frequency, so load the RFXtrx433 for an RFXtrx433! xx indicates the firmware version. Copyright 2011-2017, RFXCOM RFXtrx Version 5.37 page 22 / 50 · Click the Write device button and the RFXtrx is flashed. · Click on the Normal Execution Mode button to set the RFXtrx to running mode. Note: Receiver Settings are lost in Type1 and Type2 firmware after an update and have to be set again. Copyright 2011-2017, RFXCOM RFXtrx Version 5.37 page 23 / 50 7. RFXtrx433 special device codes 7.1. Remote commands 7.1.1. X10 RF Remote Dec Hex 2 02 18 12 34 22 56 38 58 3A 64 40 66 42 82 52 96 60 98 62 99 63 100 64 Button 0 8 4 Rewind Info CHAN+ 2 Ent VOL+ 6 Stop Pause 112 70 113 71 114 72 115 73 116 74 117 75 118 76 119 77 120 78 121 79 123 7B 124 7C 125 7D Cursor-left Cursor-right Cursor-up Cursor-down Cursor-up-left Cursor-up-right Cursor-down-right Cursor-down-left left mouse left mouse-End Drag right mouse right mouse-End 130 82 146 92 160 A0 162 A2 176 B0 182 B6 184 B8 186 BA 192 C0 194 C2 201 C9 209 D1 210 D2 211 D3 212 D4 213 D5 214 D6 215 D7 216 D8 217 D9 224 E0 226 E2 242 F2 255 FF 1 9 MUTE 5 Play Menu Fast Forward A+B CHAN3 Exit MP3 DVD CD PC / Shift-4 Shift-5 Shift-Ent Shift-Teletext Text Shift-Text VOL7 Teletext Record Copyright 2011-2017, RFXCOM RFXtrx Version 5.37 page 24 / 50 7.1.2. ATI Remote Wonder Dec Hex 0 00 1 01 2 02 3 03 4 04 5 05 6 06 7 07 8 08 9 09 10 0A 11 0B 12 0C 13 0D 14 0E 15 0F 16 10 17 11 18 12 19 13 20 14 21 15 22 16 23 17 24 18 25 19 26 1A 27 1B 28 1C 29 1D 30 1E 31 1F 32 20 33 21 34 22 35 23 36 24 37 25 38 26 39 27 40 28 41 29 Button A B power TV DVD ? Guide Drag VOL+ VOLMUTE CHAN+ CHAN1 2 3 4 5 6 7 8 9 txt 0 snapshot ESC C ^ D TV/RADIO < OK > <E v F Rewind Play Fast forward Record Stop Pause 56 38 57 39 58 3A 112 70 113 71 114 72 115 73 116 74 117 75 118 76 119 77 120 78 121 79 124 7C 125 7D 44 2C 45 2D 46 2E 47 2F 48 30 49 31 50 32 51 33 52 34 53 35 54 36 55 37 TV VCR RADIO TV Preview Channel list Video Desktop red green yellow blue rename TAB Acquire image Copyright 2011-2017, RFXCOM RFXtrx Version 5.37 edit image Full screen DVD Audio Cursor-left Cursor-right Cursor-up Cursor-down Cursor-up-left Cursor-up-right Cursor-down-right Cursor-down-left V V-End X X-End page 25 / 50 7.1.3. ATI Remote Wonder Plus Dec Hex 0 00 1 01 2 02 3 03 4 04 5 05 6 06 7 07 8 08 9 09 10 0A 11 0B 12 0C 13 0D 14 0E 15 0F 16 10 17 11 18 12 19 13 20 14 21 15 22 16 23 17 24 18 25 19 26 1A 27 1B 28 1C 29 1D 30 1E 31 1F 32 20 33 21 34 22 Button A B power TV DVD ? Guide Drag VOL+ VOLMUTE CHAN+ CHAN1 2 3 4 5 6 7 8 9 txt 0 Open Setup Menu C ^ D FM < OK > Max/Restore Window E v 35 23 36 24 37 25 38 26 39 27 40 28 41 29 42 2A 43 2B 44 2C 45 2D 46 2E 47 2F 48 30 49 31 50 32 51 33 52 34 53 35 54 36 55 37 56 38 57 39 58 3A 112 70 113 71 114 72 115 73 116 74 117 75 118 76 119 77 120 78 121 79 124 7C 125 7D F Rewind Play Fast forward Record Stop Pause TV2 Clock TV VCR RADIO TV Preview Channel list Video Desktop red green yellow blue rename TAB Acquire image edit image Full screen DVD Audio Cursor-left Cursor-right Cursor-up Cursor-down Cursor-up-left Cursor-up-right Cursor-down-right Cursor-down-left Left Mouse Button V-End Right Mouse Button X-End Copyright 2011-2017, RFXCOM RFXtrx Version 5.37 page 26 / 50 7.1.4. Medion Remote Dec Hex 0 00 1 01 2 02 3 03 4 04 5 05 6 06 7 07 8 08 9 09 10 0A 11 0B 12 0C 13 0D 14 0E 15 0F 16 10 17 11 18 12 19 13 20 14 21 15 22 16 23 17 24 18 25 19 26 1A 27 1B 28 1C 29 1D 30 1E 31 1F 32 20 33 21 34 22 35 23 36 24 37 25 38 26 39 27 40 28 41 29 44 2C 45 2D 46 2E 47 2F 48 30 49 31 50 32 51 33 52 34 53 35 Button Mute B power TV DVD Photo Music Drag VOLVOL+ MUTE CHAN+ CHAN1 2 3 4 5 6 7 8 9 txt 0 snapshot ESC DVD MENU ^ Setup TV/RADIO < OK > <E v F Rewind Play Fast forward Record Stop Pause TV VCR RADIO TV Preview Channel list Video Desktop red green yellow blue 54 36 55 37 56 38 57 39 58 3A 112 70 113 71 114 72 115 73 116 74 117 75 118 76 119 77 120 78 121 79 124 7C 125 7D Copyright 2011-2017, RFXCOM RFXtrx Version 5.37 rename TAB Acquire image edit image Full screen DVD Audio Cursor-left Cursor-right Cursor-up Cursor-down Cursor-up-left Cursor-up-right Cursor-down-right Cursor-down-left V V-End X X-End page 27 / 50 7.2. Harrison address conversion to switch settings The address used is converted to the address selected in the Harrison curtain motor using the table below. switch 1 2 3 4 H H H H A 0110 B 0111 C 0100 D 0101 E 1000 F 1001 G 1010 H 1011 I 1110 J 1111 K 1100 L 1101 M 0000 N 0001 O 0010 P 0011 5 6 7 8 X X X X 1 0000 2 0001 3 0010 4 0011 5 0100 6 0101 7 0110 8 0111 9 1000 10 1 0 0 1 11 1 0 1 0 12 1 0 1 1 13 1 1 0 0 14 1 1 0 1 15 1 1 1 0 16 1 1 1 1 H H H H = House code X X X X = device code Switch position in the motor: Up = 1 Middle = not used!!!! Down = 0 Examples: If you assign the address E7 (1000 0110) to the curtain motor then set the switches to: 1=up, 2=down, 3=down, 4=down, 5=down, 6=up, 7=up, 8=down If you assign the address A2 (0110 0001) to the curtain motor then set the switches to: 1=down, 2=up, 3=up, 4=down, 5=down, 6=down, 7=down, 8=up Copyright 2011-2017, RFXCOM RFXtrx Version 5.37 page 28 / 50 7.3. Flamingo, AB400, IMPULS, Sartano, Brennenstuhl, SilverCrest 91089, Cranenbroek switch settings Use type ELRO AB400D Note that the HC (House Code A-P) is the house code used in programs and has no direct relation with the A,B,C,D,E buttons on the remotes! 1 2 3 4 HC========== A 0000 B 0001 C 0010 D 0011 E 0100 F 0101 G 0110 H 0111 I 1000 J 1001 K 1010 L 1011 M 1100 N 1101 O 1110 P 1111 <== switches 5 A B C D E 5 A B C D E 5 6 7 8 9 10 5 6 7 8 9 10 DC==================DC============= 1 0 0 0 0 0 0 33 0 0 0 0 0 1 2 0 0 0 1 0 0 34 0 0 0 1 0 1 3 0 0 1 0 0 0 35 0 0 1 0 0 1 4 0 0 1 1 0 0 36 0 0 1 1 0 1 5 0 1 0 0 0 0 37 0 1 0 0 0 1 6 0 1 0 1 0 0 38 0 1 0 1 0 1 7 0 1 1 0 0 0 39 0 1 1 0 0 1 8 0 1 1 1 0 0 40 0 1 1 1 0 1 9 1 0 0 0 0 0 41 1 0 0 0 0 1 10 1 0 0 1 0 0 42 1 0 0 1 0 1 11 1 0 1 0 0 0 43 1 0 1 0 0 1 12 1 0 1 1 0 0 44 1 0 1 1 0 1 13 1 1 0 0 0 0 45 1 1 0 0 0 1 14 1 1 0 1 0 0 46 1 1 0 1 0 1 15 1 1 1 0 0 0 47 1 1 1 0 0 1 16 1 1 1 1 0 0 48 1 1 1 1 0 1 17 0 0 0 0 1 0 49 0 0 0 0 1 1 18 0 0 0 1 1 0 50 0 0 0 1 1 1 19 0 0 1 0 1 0 51 0 0 1 0 1 1 20 0 0 1 1 1 0 52 0 0 1 1 1 1 21 0 1 0 0 1 0 53 0 1 0 0 1 1 22 0 1 0 1 1 0 54 0 1 0 1 1 1 23 0 1 1 0 1 0 55 0 1 1 0 1 1 24 0 1 1 1 1 0 56 0 1 1 1 1 1 25 1 0 0 0 1 0 57 1 0 0 0 1 1 26 1 0 0 1 1 0 58 1 0 0 1 1 1 27 1 0 1 0 1 0 59 1 0 1 0 1 1 28 1 0 1 1 1 0 60 1 0 1 1 1 1 29 1 1 0 0 1 0 61 1 1 0 0 1 1 30 1 1 0 1 1 0 62 1 1 0 1 1 1 31 1 1 1 0 1 0 63 1 1 1 0 1 1 32 1 1 1 1 1 0 64 1 1 1 1 1 1 <== switches <== OR switches Examples: A1 0 0 0 0 0 0 0 0 0 0 A15 0 0 0 0 1 1 1 0 0 0 N2 1 1 0 1 0 0 0 1 0 0 N11 1 1 0 1 1 0 1 0 0 0 0 = switch off 1 = switch on Copyright 2011-2017, RFXCOM RFXtrx Version 5.37 page 29 / 50 7.4. Energenie 5-gang 429.950 To know the codes to use open the remote and check the 1 to 5 jumpers connected. If a jumper connection is open it is a 1. If connected it is a 0 (zero) 1 2 3 4 HC========= A 0000 B 0001 C 0010 D 0011 E 0100 F 0101 G 0110 H 0111 I 1000 J 1001 K 1010 L 1011 M 1100 N 1101 O 1110 P 1111 jumper setting in the remote If jumper 5 is open (1) than add 5 to the remote code. Examples: Jumper 1 2 3 4 5 1 0 0 0 0 1 0 0 0 1 Button Code 1 I1 1 I6 Copyright 2011-2017, RFXCOM RFXtrx Version 5.37 page 30 / 50 7.5. Phenix, IDK YC-4000S switch settings Use type ELRO AB400D Note that the HC (House Code A-P) is the house code used in programs and has no direct relation with the A,B,C,D,E buttons on the remotes! HC switch 1 2 3 4 ============ A 0000 B 0001 C 0010 D 0011 E 0100 F 0101 G 0110 H 0111 I 1000 J 1001 K 1010 L 1011 M 1100 N 1101 O 1110 P 1111 DC switch 5 A B C D ============== 1 00000 2 00010 3 00100 4 00110 5 01000 6 01010 7 01100 8 01110 9 10000 10 1 0 0 1 0 11 1 0 1 0 0 12 1 0 1 1 0 13 1 1 0 0 0 14 1 1 0 1 0 15 1 1 1 0 0 16 1 1 1 1 0 17 0 0 0 0 1 18 0 0 0 1 1 19 0 0 1 0 1 20 0 0 1 1 1 21 0 1 0 0 1 22 0 1 0 1 1 23 0 1 1 0 1 24 0 1 1 1 1 25 1 0 0 0 1 26 1 0 0 1 1 27 1 0 1 0 1 28 1 0 1 1 1 29 1 1 0 0 1 30 1 1 0 1 1 31 1 1 1 0 1 32 1 1 1 1 1 Copyright 2011-2017, RFXCOM RFXtrx Version 5.37 page 31 / 50 7.6. HE105 switch settings Unitnr 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 HE105 switches 1 2 3 4 5 0 0 0 0 0 0 0 0 0 1 0 0 0 1 0 0 0 0 1 1 0 0 1 0 0 0 0 1 0 1 0 0 1 1 0 0 0 1 1 1 0 1 0 0 0 0 1 0 0 1 0 1 0 1 0 0 1 0 1 1 0 1 1 0 0 0 1 1 0 1 0 1 1 1 0 0 1 1 1 1 1 0 0 0 0 1 0 0 0 1 1 0 0 1 0 1 0 0 1 1 1 0 1 0 0 1 0 1 0 1 1 0 1 1 0 1 0 1 1 1 1 1 0 0 0 1 1 0 0 1 1 1 0 1 0 1 1 0 1 1 1 1 1 0 0 1 1 1 0 1 1 1 1 1 0 1 1 1 1 1 Copyright 2011-2017, RFXCOM RFXtrx Version 5.37 page 32 / 50 7.7. HQ COCO-20 Note that the HC (House Code A-P) is the house code used in programs and has no direct relation with the A,B,C,D,E buttons on the remotes! 6 7 8 9 <== switches in module HC========== A 0000 B 0001 C 0010 D 0011 E 0100 F 0101 G 0110 H 0111 I 1000 J 1001 K 1010 L 1011 M 1100 N 1101 O 1110 P 1111 10 1 2 3 4 5 10 1 2 3 4 5 <== switches in module DC==================DC============== 1 0 0 0 0 0 0 33 1 0 0 0 0 0 2 0 0 0 0 0 1 34 1 0 0 0 0 1 3 0 0 0 0 1 0 35 1 0 0 0 1 0 4 0 0 0 0 1 1 36 1 0 0 0 1 1 5 0 0 0 1 0 0 37 1 0 0 1 0 0 6 0 0 0 1 0 1 38 1 0 0 1 0 1 7 0 0 0 1 1 0 39 1 0 0 1 1 0 8 0 0 0 1 1 1 40 1 0 0 1 1 1 9 0 0 1 0 0 0 41 1 0 1 0 0 0 10 0 0 1 0 0 1 42 1 0 1 0 0 1 11 0 0 1 0 1 0 43 1 0 1 0 1 0 12 0 0 1 0 1 1 44 1 0 1 0 1 1 13 0 0 1 1 0 0 45 1 0 1 1 0 0 14 0 0 1 1 0 1 46 1 0 1 1 0 1 15 0 0 1 1 1 0 47 1 0 1 1 1 0 16 0 0 1 1 1 1 48 1 0 1 1 1 1 17 0 1 0 0 0 0 49 1 1 0 0 0 0 18 0 1 0 0 0 1 50 1 1 0 0 0 1 19 0 1 0 0 1 0 51 1 1 0 0 1 0 20 0 1 0 0 1 1 52 1 1 0 0 1 1 21 0 1 0 1 0 0 53 1 1 0 1 0 0 22 0 1 0 1 0 1 54 1 1 0 1 0 1 23 0 1 0 1 1 0 55 1 1 0 1 1 0 24 0 1 0 1 1 1 56 1 1 0 1 1 1 25 0 1 1 0 0 0 57 1 1 1 0 0 0 26 0 1 1 0 0 1 58 1 1 1 0 0 1 27 0 1 1 0 1 0 59 1 1 1 0 1 0 28 0 1 1 0 1 1 60 1 1 1 0 1 1 29 0 1 1 1 0 0 61 1 1 1 1 0 0 30 0 1 1 1 0 1 62 1 1 1 1 0 1 31 0 1 1 1 1 0 63 1 1 1 1 1 0 32 0 1 1 1 1 1 64 1 1 1 1 1 1 Examples: Switch 6 7 8 9 0 1 2 3 4 5 ==================== A1 0 0 0 0 0 0 0 0 0 0 A15 0 0 0 0 1 1 1 0 0 0 N2 1 1 0 1 0 0 0 1 0 0 N11 1 1 0 1 1 0 1 0 0 0 0 = switch off 1 = switch on Copyright 2011-2017, RFXCOM RFXtrx Version 5.37 page 33 / 50 7.8. MDREMOTE V106, V107 This MDREMOTE has been tested. http://www.ultraleds.co.uk/mini-dimmer-with-rf-remote-control-12-or-24v-dc-12a-maximum.html The RFXtrx433 can only transmit MDREMOTE commands. Procedure to find the ID of the MDREMOTE: In RFXmngr enable the X10 protocol and enable "Undec on". Press a button on the MDREMOTE remote. The undecoded message contains the ID in the 2nd and 3rd byte, for example: UNDECODED NEC:20AF6801D1 The 2 bytes after 20 is the MDREMOTE ID, in this example AF 68 7.9. MDREMOTE V108, EKAB-10KRF This MDREMOTE has been tested. - http://www.ledstripkoning.nl/accessoires/dimmers-wit/draadloze-dimmer-10-knops-rf/ Procedure to find the ID of the MDREMOTE: In RFXmngr enable the Lighting4 protocol and enable "Undec on". Press a button on the MDREMOTE remote. The undecoded message contains the ID in the 2nd and 3rd byte, for example: UNDECODED ARC:201A0703FCFC The 2 bytes after 20 is the MDREMOTE ID, in this example 1A 07 7.10. Aoke relay The Aoke 12V DC - 315MHz or 433.92MHz 1 channel relay is available at www.aliexpress.com store No.110758. Indicate clearly the required frequency when ordering! The 1 channel learning relays can be used, see the picture below. For example, for 1 relay: http://www.aliexpress.com/store/product/DC12V-1CH-wireless-switch-remote-control-systemremote-control-switch-for-guard-door-window-curtain/110758_936534863.html or for 6 relays: http://www.aliexpress.com/store/product/ak-DC12V-1CH-RF-rocker-switch-livolo-switch-system-inchina-j-12a-108d-smart-house/110758_1007306574.html The jumper next to the learning button defines to operating mode: Open = momentary 1-2 = toggle mode 2-3 = on/off mode (to be used with the RFXtrx) Copyright 2011-2017, RFXCOM RFXtrx Version 5.37 page 34 / 50 7.11. SEAV TXS4 The ID can be found using RFXmngr and enable only ByronSX and undec on. Or calculate the ID: A SW1 switch on = 1 |---------SW1------------| 1 2 3 4 5 6 7 8 9 10 0 x x x | x x x x | x x x 0 | 0 1 0 1 For example SW1 = on off on off on off on off on off The ID will become: |---------SW1-----------| 1 2 3 4 5 6 7 8 9 10 0 1 0 1 | 0 1 0 1 | 0 1 0 0 | 0 1 0 1 this is hex: 5 5 4 5 7.12. How to find the dx.com RGB LED strip driver ID Valid for the TRC02 remote with 2 batteries. Flash the RFXtrx433 with Type2 firmware to be able to receive the remote ID in RFXmngr. In RFXmngr enable only the LightwaveRF (AD) protocol. ------------------------------------------------ Packettype = Lighting5 subtype = RGB TRC02 Sequence nbr = 5 ID = FCC48B Command = On Signal level = 8 The ID is: FC C4 8B If necessary flash the RFXtrx433 back to Type1 or ext if Type2 does not support devices you need. (See chapter 2.2) 7.13. How to find the dx.com RGB LED strip driver ID (rev. 2) Valid for the TRC02 remote with 3 batteries and ebay.com 191481664563. In RFXmngr enable only the Lighting4 protocol. ------------------------------------------------ Packettype = Lighting4 subtype = PT2262 Sequence nbr = 29 Code = 161C84 The ID is: 16 1C 7.14. How to find the Eurodomest ID You can assign a random ID to the Eurodomest. If you want to use the same ID as the remote you can find the ID of the remote using RFXmngr. Start RFXmngr and enable only the Lighting4 protocol. Press a button on the remote and you will receive a message like: ------------------------------------------------ Packettype = Lighting4 subtype = PT2262 Sequence nbr = 12 Code = 6DFE0F The ID is: 6 DF E0 Note: Eurodomest can also be controlled using ARC. Copyright 2011-2017, RFXCOM RFXtrx Version 5.37 page 35 / 50 7.15. How to find the Screenline ID You can assign a random ID to the Screenline. If you want to use the same ID as the remote you can find the ID of the remote using RFXmngr. Start RFXmngr and enable only the Lighting4 protocol and undec on. Press a button on the remote and you will receive a message like: ------------------------------------------------ Packettype = UNDECODED RF Message UNDECODED ARC:40000F7BD1D2AF04B7 The ID starts at the 7th character, in this example the ID = 7B D1 7.16. How to find the Avantek remote ID You can find the ID of the remote using RFXmngr. Start RFXmngr and enable only the Lighting4 protocol. Press a button on the remote and you will receive a message like: Packettype = Lighting4 subtype = PT2262 Sequence nbr = 3 Code = 122336 decimal:1188662 S1- S24 = 0001 0010 0010 0011 0011 0110 Pulse = 280 usec Signal level = 7 -64dBm The ID to be used is 1 22 33 Copyright 2011-2017, RFXCOM RFXtrx Version 5.37 page 36 / 50 8. Blyss commands Some Blyss devices, like the Blyss motors, require a special command sequence number. To simplify it; 0,1,2,3,4,0,1,... This sequence number is normally created by the Blyss remote but now also by the RFXtrx433. If you use a Blyss remote and the application (Domoticz, DomotiGa, Homeseer...) does not sync with the received Blyss command you will see that you need to send multiple commands with the RFXtrx433 before the Blyss device will respond. For example, The Blyss remote transmits with the sequence numbers 0,1,2 If the RFXtrx433 transmits now with sequence number 0 it will not be seen by the Blyss device as a valid command and at the time the RFXtrx433 transmits the commands 1,2,3 the command will be detected as valid when it receives the command with sequence number 3. The same is true for the remote. If you transmit commands with the RFXtrx433 and after that with a Blyss remote you need to transmit several commands with the remote before the Blyss device responds. I guess the same behaviour will show if you use multiple Blyss remotes. 9. Somfy RTS Somfy RTS* devices can only be controlled by the RFXtrx433E. (not with the RFXtrx433) The RFXtrx433E version is an RFXtrx433 with additional hardware to enable the RFY protocol used to control Somfy RTS. The 433.42MHz transmitter in the RFXtrx433E is used for a reliable control of the Somfy RTS devices over a large distance and through walls. The RFXtrx433E 433.92MHz transmitter is used to control all other devices. To pair the Somfy RTS device: · Select a unique ID and unitcode for the RFXCOM RFY device. · Disconnect power from all Somfy RTS devices except the device to pair. · Press the Program button > 2 seconds on the original Somfy remote until the Somfy device responds. · Transmit a Program command with the RFXtrx433E. The Somfy RTS device should respond indicating the pair command was successful. The RFXCOM RFY remote is registered in the RFXtrx433E by sending a Program command. Up to 40 RFXCOM RFY remotes can be registered in the RFXtrx433E. Remotes can be erased from the RFXtrx433E using the RFXmngr program. The Somfy RTS device can be controlled by any application as long as the same ID and Unit Code are used. For example if the RTS device is paired using RFXmngr with ID=1 02 03 and Unit Code 1, the RTS device can be controlled with Homeseer using the same ID and unit code. To control Somfy Centralis modules use the > 2 seconds (RFY2) commands. * Somfy RTS are registered trademarks of Somfy System, Inc. Copyright 2011-2017, RFXCOM RFXtrx Version 5.37 page 37 / 50 10. BlindsT6 To add a RFXtrx433(E) BlindsT6 device to the blinds motor: 1. press the "program" button twice on the original remote ==> 2 beeps 2. transmit the "confirm" command with the RFXtrx433(E) ==> 5 beeps 10.1. Dooya DT82TV, DT82TN · Select a random ID different from all zeroes and a unit code 1 to 15 · Press the program button on the motor until the LED lights up · Transmit a Confirm command · The LED on the motor starts blinking · Transmit again a Confirm command · The LED on the motor blinks 5 times · The motor can be controlled now by the RFXtrx433(E) 11. Lucci Air fan Select the ID for switch settings: ID Remote switches 1 2 3 4 0 0 0 0 0 1 0 0 0 1 2 0 0 1 0 3 0 0 1 1 4 0 1 0 0 5 0 1 0 1 6 0 1 1 0 7 0 1 1 1 8 1 0 0 0 9 1 0 0 1 A 1 0 1 0 B 1 0 1 1 C 1 1 0 0 D 1 1 0 1 E 1 1 1 0 F 1 1 1 1 0 = ON Copyright 2011-2017, RFXCOM RFXtrx Version 5.37 page 38 / 50 12. Transmit undecoded ARC commands. Plug-in modules or other equipment with a PT2262 can be controlled using Lighting4. There are a lot of brands using the PT2262 and some of them use the same timing (350) as used by the ARC devices but a different protocol definition. Messages will be received as undecoded ARC messages if the protocol definition does not match the definition of the ARC protocol. Remote commands are received as ARC commands with a wrong house and device code and/or command code or as undecoded ARC messages if "undec on" is enabled. Decoding of these remotes is therefore not possible because they overlap the ARC protocol partly. But transmitting these commands is possible using the Lighting4 command. So if we receive this command UNDECODED ARC:18014403: (18 is not used) hex to binary table 0=0 0 0 0 1=0 0 0 1 2=0 0 1 0 3=0 0 1 1 4=0 1 0 0 5=0 1 0 1 6=0 1 1 0 7=0 1 1 1 8=1 0 0 0 9=1 0 0 1 A=1 0 1 0 B=1 0 1 1 C=1 1 0 0 D=1 1 0 1 E=1 1 1 0 F=1 1 1 1 0 1 4 4 0 3 = selection box 0000 0001 0100 0100 0000 0011 Not selected = 0, box selected = 1 And the Lighting4 command contains the same "undec code" 01 44 03: Lighting4 command:09 13 00 04 01 44 03 01 5E 00 pulse timing is 350 = hex 015E Another example: For this command UNDECODED ARC:18014430 set on the Lighting4 tab in RFXmngr selection box 1 to 24 to 0 1 4 4 3 0 = 0000 0001 0100 0100 0011 0000 Copyright 2011-2017, RFXCOM RFXtrx Version 5.37 page 39 / 50 13. MCZ pellet stove. In the Type2 firmware zip file which is available on the downloads page you will find a special firmware RFXtrxMCZ.hex that enables you to know the ID of the your MCZ remote. Flash the RFXtrxMCZ.hex firmware in your RFXtrx433(E) and start RFXmngr. Transmit a command with the MCZ remote and you will receive the information. The ID in this example is 81 3F 22 Flash now Type2 or Ext firmware in your RFXtrx433(E) and you can control your MCZ stove using the received ID. Important: remove the batteries from the original remote before you start using the RFXtrx433 to control the MCZ stove! Copyright 2011-2017, RFXCOM RFXtrx Version 5.37 page 40 / 50 14. Known Lighting4 devices 14.1. Proluxx projection screen Use Lighting4 with a pulse timing of 360 UP STOP DOWN RESET 1110 1101 0101 1001 0101 0010 1110 1101 0101 1001 0101 1000 1110 1101 0101 1001 0101 0100 1110 1101 0101 1001 0101 0001 ED 59 52 ED 59 58 ED 59 54 ED 59 51 14.2. Kingpin (KP100) projection screen Use Lighting4 with a pulse timing of 1040 UP STOP DOWN PROGRAM 1110 0001 0100 0010 0010 0010 1110 0001 0100 0010 0010 0100 1110 0001 0100 0010 0010 1000 1110 0001 0100 0010 0010 0001 E1 42 22 E1 42 24 E1 42 28 E1 42 21 14.3. Mercury remote control mains sockets http://mercury.avsl.com/product?range=ME5124 Use Lighting4 with a pulse timing of 188 1 OFF 01000100010101010011 1100 1 ON 01000100010101010011 0011 2 OFF 01000100010101011100 1100 2 ON 01000100010101011100 0011 3 OFF 01000100010101110000 1100 3 ON 01000100010101110000 0011 4 OFF 01000100010111010000 1100 4 ON 01000100010111010000 0011 5 OFF 01000100011101010000 1100 5 ON 01000100011101010000 0011 14.4. Conrad 034911 sockets http://www.conrad.nl/ce/nl/product/034911/Draadloze-schakelaarset-5-delig Use Lighting4 with a pulse timing of 425 Off = last 2 digits: 00 ON = last 2 digits: 01 Group I II III IV Unit 1 OFF 1 OFF 1 OFF 1 OFF 00 01 01 01 00 01 01 01 01 01 01 00 01 00 01 01 00 01 01 01 01 01 01 00 01 01 00 01 00 01 01 01 01 01 01 00 01 01 01 00 00 01 01 01 01 01 01 00 I 1 OFF 00 01 01 01 00 01 01 01 01 01 01 00 I 2 OFF 00 01 01 01 01 00 01 01 01 01 01 00 I 3 OFF 00 01 01 01 01 01 00 01 01 01 01 00 I 4 OFF 00 01 01 01 01 01 01 00 01 01 01 00 I 1 OFF 00 01 01 01 00 01 01 01 01 01 01 00 I 1 ON 00 01 01 01 00 01 01 01 01 01 01 01 Copyright 2011-2017, RFXCOM RFXtrx Version 5.37 page 41 / 50 15. FAQ 15.1. Receive has stopped suddenly but transmit works. Most probably a sensor is transmitting constantly. This could be for example an X10 MS13 motion sensor or weather sensor with almost empty battery. Or an outside weather sensor filled with water. Or a remote with a button pressed. Test the RFXtrx with a remote or sensor on another location (> 1km away) using RFXmngr on a Windows system or laptop. 15.2. Can I increase the receive/transmit range of the RFXtrx? First check chapter 2.5 for the best place for the RFXtrx antenna. The switch board is not the best place for the RFXtrx because of all metal objects that will absorb or reflect the RF signals. It is also advised to place the RFXtrx far away from PC's, routers, Raspberry PI ... because of the RF noise those products produce and this will reduce the receive range very much. You can connect another 50ohm 70cm/433MHz antenna with more gain. For example http://www.ebay.com/itm/290979680030 Install this antenna on a metal plate of at least 30 cm for optimum result. 15.3. The RFXtrx USB connection disconnects sometimes. This happens mostly on Raspberry PI with a low quality power supply. Solution is to use a powered USB hub with a good quality power supply. It can also happen if the USB cable is running along a power cable and a power device is switched on that produces a high power spike like TL. Solution is to separate the USB cable from all other cables and/or use a powered USB hub with a good quality power supply. 15.4. I have a 433.92MHz sensor/remote but this device is not received. Besides the frequency the used protocol and modulation type is also important. See chapter 2 for the list of supported devices. 15.5. The wall plug is switched by the remote. The remote is received but the RFXtrx does not switch the module. The remote transmits several protocols. The protocol used by the wall plug is not received by the RFXtrx but some other protocols are received. Solution: For the HomeEasy EU- HE8xx series: reset the module to remove all paired remotes and pair the module with the RFXtrx433E and one of remote codes that is received. For IT modules FA500/PROmax: Pair the RFXtrx433E with the module using an IT device and select a random ID. The received remote code can be used to know if the module is switched by the remote. Copyright 2011-2017, RFXCOM RFXtrx Version 5.37 page 42 / 50 16. EC Declaration of Conformity EC Declaration of Conformity RFXCOM declares that the product: RFXtrx Brand: RFXCOM Type: RFXtrx433E conforms with the essential requirements and other relevant provisions of the following directives and complies with the following standards applied: R&TTE Directive 99/5/EC EN 300 220-1 V2.4.1 (2012-05) EN 300 220-2 V2.4.1 (2012-05) Low-voltage Directive 2006/95/EC IEC 60950-1 (2005-12) EMC Directive 2004/108/EC EN 301 489-1 V1.9.2 (2011-09) EN 301 489-3 V1.4.1 (2002-08) Copyright 2011-2017, RFXCOM RFXtrx Version 5.37 page 43 / 50 17. Warning: · RF signals are possible disturbed and it has not been justified for this equipment at uses in circumstances where life-threatening or dangerous situations are possible. · RFXCOM HARDWARE AND SOFTWARE IS NOT INTENDED FOR USE IN THE OPERATION OF NUCLEAR FACILITIES, AIRCRAFT NAVIGATION OR COMMUNICATION SYSTEMS, AIR TRAFFIC CONTROL SYSTEMS, LIFE SUPPORT MACHINES OR OTHER EQUIPMENT IN WHICH THE FAILURE OF THE SOFTWARE COULD LEAD TO DEATH, PERSONAL INJURY, OR SEVERE PHYSICAL OR ENVIRONMENTAL DAMAGE. 18. License · You are allowed to use RFXCOM software, protocols and Written Materials with RFXCOM hardware only. · All copyright and other proprietary notices associated with RFXCOM software, protocols and Written Materials shall be visible to all users. · You may not sell, distribute, loan, rent, lease, license, sublicense or otherwise assign or transfer RFXCOM software or RFXtrx protocols or Written Materials unless expressly authorized in writing by RFXCOM. · You may not use any RFXCOM device, software or protocol as part of an exclusive or patented product without the express prior written permission of RFXCOM. · You may not alter, modify, adapt or create derivative works based on any part of RFXCOM software or protocols or Written Materials in any way, including translating, reverse engineering, disassembling or decompiling the software. 19. Copyright notice · All RFXCOM hardware, software, protocols and Written Materials are protected by copyright laws, and may not be reproduced, republished, distributed, transmitted, displayed, broadcast or otherwise exploited in any manner without the express prior written permission of RFXCOM. · Netherlands Copyright and international treaty provisions protect the SOFTWARE, HARDWARE, RFXtrx protocols and Written Materials and shall be subject to the exclusive jurisdiction of the Netherlands Courts · RFXCOM reserves all rights not expressly granted herein. Copyright 2011-2017, RFXCOM RFXtrx Version 5.37 page 44 / 50 20. Revision history Version 0.0 August 18, 2011 Initial version. Version 1.0 October 30, 2011 RFXflash under Mono added. Version 2.0 December 30, 2011 Updated for the production version with FTDI USB chip Version 2.1 January 18, 2012 Link for ACM to serial port added in Linux instruction. EC Declaration of Conformity added Version 2.2 February 8, 2012 Protocols overview added Screen dumps updated Version 2.3 February 16, 2012 Novatys planned Version 2.4 February 25, 2012 General information updated Version 2.5 March 1, 2012 Chapter added how to run RFXmngr or RFXflash on Linux. Version 2.6 March 14, 2012 Code tables added Cresta, UPM added Version 2.7 March 15, 2012 Flash procedure updated Version 2.8 March 31, 2012 Phenix table added Version 2.9 March 31, 2012 AB400 and Phenix address extended Version 2.10 April 16, 2012 Linux USB - tty configuration updated Version 2.11 May 14, 2012 List of supported protocols updated. Version 2.12 June 8, 2012 Chapter added how to run RFXmngr or RFXflash on Mac OS Version 2.13 July 15, 2012 List of supported protocols updated Version 2.14 August 4, 2012 List of enabled protocols influence added RFXtrx315 added Version 2.15 August 18, 2012 Enabled protocols table changed Version 2.16 August 26, 2012 Rubicson stektermometer added ATI Remote Wonder II added Version 2.17 August 28, 2012 Table "sensitivity influenced" updated Version 2.18 September 18, 2012 Chapter 2.3 updated: BlindsT0 disables all other protocols Version 2.19 September 25, 2012 RFXFlash version required changed to 4.0.0.0 Version 2.20 September 28, 2012 RF range reduction guide added Version 2.21 October 18, 2012 BlindsT2 and BlindsT3 added Version 2.22 October 24, 2012 Sartano added Version 2.23 October 31, 2012 Copyright 2011-2017, RFXCOM RFXtrx Version 5.37 page 45 / 50 Sensitivity table updated Version 2.24 November 7, 2012 Protocol table extended with the protocols to enable for receive Version 2.25 November 14, 2012 HE105 switch settings added Version 2.26 November 28, 2012 undec on explained Version 2.27 December 4, 2012 Use of Lighting4 commands for undec ARC Brennenstuhl added Version 2.28 December 18, 2012 Receiver tab removed from RFXmngr Version 2.29 December 27, 2012 Lighting4 receive added Version 2.30 January 1, 2013 Raex motor added Version 3.00 January 4, 2013 RFXtrx433 Type1/Type2 firmware added Version 3.01 February 4, 2013 Supported protocols list updated Version 4.00 February 21, 2013 Chapter 8 - Lighting4 screen updated for RFXmngr 11.0.0.0 Known Lighting4 chapter added Version 4.01 March 13, 2013 Receive of LaCrosse sometimes influenced by enabled Hideki Version 4.02 June 8, 2013 MDREMOTE LED dimmer added Conrad RSL2 added Energenie added Version 4.03 September 27, 2013 How to find the MDREMOTE ID (chapter 7.6) WS1200 added Byron SX Chime added Version 4.04 November 15, 2013 Maverick ET-732 added Alecto SA30 added Oregon EW109 added Revolt added Version 4.05 December 5, 2013 Blyss command explanation added. Lighting4 - Mercury added Lighting5 dx.com RGB LED controller added Version 4.06 December 27, 2013 Chapter 2.2 updated Version 4.07 February 10, 2014 Chapter 7.8 added: how to find the dx.com RGB LED strip driver ID Version 4.08 March 20, 2014 ARC and Oregon3.0 updated in table 2.4. Energenie 5-gang 429.950 added Version 4.09 April 4, 2014 BlindsT6 - DC106, YOODA, Röhrmotor24 RMF added Version 4.10 April 7, 2014 BlindsT7 - Forest added Version 4.11 April 28, 2014 RGB LED clarified AD is LightwaveRF Version 4.12 May 21, 2014 Kambrook RF3672 added RFY protocol added Copyright 2011-2017, RFXCOM RFXtrx Version 5.37 page 46 / 50 Somfy programming instructions added Supported protocol list RFXtrx433 updated. Protocol list by function added Version 4.13 May 31, 2014 Opus TX300/Imagintronix Soil sensor added Version 4.14 June 18, 2014 Prega sensor added Conrad 34911 Lighting4 coding added Version 4.15 June 25, 2014 Kambrook, Rubicson, Viking supported in ext firmware Number of RFY remotes increased from 16 to 30 Version 4.16 June 29, 2014 RFXmngr cannot be used on Linux Version 4.17 July 3, 2014 CoCo GDR2 added Version 4.18 July 14, 2014 Opus TX300 link added Version 4.19 July 25, 2014 Aoke relay added Version 4.20 August 25, 2014 Enabling protocols clearified. Version 4.21 September 5, 2014 Meade sensors added Oregon BTHGN129 sensor added Version 4.22 September 18, 2014 Eurodomest added (NL - Action) Byron MP001 added WT0122 added Procedures added to find the Eurodomest and TRC02 ver2 ID Version 4.23 September 24, 2014 Proove TSS330 fridge/freezer sensor added Version 4.24 October 9, 2014 BlindsT0 added in ext firmware Alecto WS1700 and compatibles added Version 4.25 December 13, 2014 Smartwares radiator valve added Proove TSS320 sensor added Version 4.26 January 2, 2015 SelectPlus200689101 White Chime (Action NL) added Version 4.27 January 6, 2015 SelectPlus200689103 Black Chime (Action NL) added Version 4.28 January 7, 2015 Proove outdoor sensors 311346 & 311501 added Etekcity Wireless Remote Control Outlet Switch (US) Version 5.00 January 10, 2015 Copyright message updated License chapter added RFXmngr information updated Version 5.01 February 27, 2015 Chapter 2.5 Lighting4 receive is reduced with HomeEasy EU enabled. Chamberlain tubular motor added Sunpery blind motors added DEA Systems receivers added Envivo ENV-1348 chime added Alecto WS4500 added Copyright 2011-2017, RFXCOM RFXtrx Version 5.37 page 47 / 50 Version 5.02 March 18, 2015 1byOne Easy Chime added BTX blind motors added Dolat DLM-1 blind motors added OTIO added Version 5.03 March 19, 2015 TFA 30.3160 pool sensor added Version 5.04 April 14, 2015 Chapter 4 updated with restrictions on Lighting4 Siemens SF01 LF959RA50/LF259RB50/LF959RB50 extractor hood added Maplin N78KA added Version 5.05 May 2, 2015 Dooya blind motors added Louvolite one touch motorised blinds added Alecto WS3500 added Version 5.06 May 4, 2015 Current dx.com TRC02 LED drivers have a different protocol and are not supported. Version 5.07 June 1, 2015 WH2 temperature humidity sensor added RGB LED controller http://www.ebay.com/itm/191481664563 (maybe dx.com 227892) Version 5.08 July 31, 2015 Oregon MSR939 added ESMO blind motors added Brel blind motors added Blinds T6 type motors now also supported in Ext firmware Supported devices table 2.2.2. updated Version 5.09 Aug 12, 2015 Luxaflex blind motors added Version 5.10 Aug 17, 2015 JVS screen motors added Livolo NL link added Version 5.11 Aug 31, 2015 ASA motors added Version 5.12 Sept 14, 2015 Home Confort added Version 5.13 Oct 2, 2015 Oregon GR101 received in Type1 firmware Conrad RSL sensors received in Type2 firmware Version 5.14 Oct 7, 2015 Quotidom blinds motor added Version 5.15 Nov 06, 2015 Banggood temp-hum sensor added Legrand CAD radio added Version 5.16 Nov 26, 2015 Proluxx codes corrected Version 5.17 Dec 24, 2015 RFXflash procedure updated Rubicson pool sensor 48.019 added Inovalley SM80 plant sensor added Lucci Air fan added Version 5.18 Jan 1, 2016 1byone Drive Way alarm added Version 5.19 Feb 6, 2016 Avantek added ASP blinds motors BlindsT11 added Maverick ET-733 added Profiles PAC-326R Belcanto chime added HQ COCO-20 added Copyright 2011-2017, RFXCOM RFXtrx Version 5.37 page 48 / 50 Version 5.20 Feb 18, 2016 BlindsT12 Confexx CNF24-2435 added IT FA500, PROmax... added Ext2 fimware overview added in chapter 2 Auriol Z31055B-TX added Chuango, Eminent security sensors added Version 5.21 May 6, 2016 Cartelectronic TIC and Encoder added FAQ chapter added Version 5.22 May 14, 2016 Corrected: TX95 is using the Rubicson protocol MDRemote V108 added Version 5.23 June 10, 2016 Motolux blinds motor added Auriol H13726, Hama EWS1500, Meteoscan W155/W160, Ventus WS155 added FAQ updated Version 5.24 June 21, 2016 Seav TXS4 added Version 5.25 Aug 6, 2016 ORNO added Version 5.26 Sept 6, 2016 Added: How to find the SEAV TXS4 ID Version 5.27 Oct 09, 2016 Westinghouse fan 7226640 added THN129 added TFA 30.3056 pool sensor added Version 5.28 Oct 19, 2016 MCZ pellet stove added Alecto SA33 added Smartwares RM174RF smoke detector added Version 5.29 Nov 27, 2016 SilverCrest 91089 added Mertik G6R-H4S added Marquant 943134 MCZ pellet stove instructions added Version 5.30 Dec 6, 2016 Kerui security sensors added Screenline added Version 5.31 Dec 15, 2016 Flamingo smartwares SF501 added Version 5.32 Jan 02, 2017 Kangtai, Cotech added Version 5.33 Feb 01, 2017 Cranenbroek added Unitec 48110 EIM 826 added SilverCrest 60494 added WSD10 added Version 5.34 March 08, 2017 Housegard Origo smoke detector added Pearl NC-7159 added Ambient Weather & Froggit F007TH added TFA 30.3208.02 sensor added Version 5.35 March 20, 2017 Silverline Premium motor added Dooya DT82 instructions added Copyright 2011-2017, RFXCOM RFXtrx Version 5.37 page 49 / 50 Version 5.36 April 25, 2017 Quigg added OTIO EHS5050 added Blyss temperature/humidity sensor 630467 added Outlook Motion Blinds added Version 5.37 May 5, 2017 Cartelectronic TIC in Type2 and Ext2 Copyright 2011-2017, RFXCOM RFXtrx Version 5.37 page 50 / 50Mac OS X 10.12.5 Quartz PDFContext Voorvertoning