HD 271 S1

LAB02

Test Report BLE

Dongguan Mingqin Xin Electronics Co., Ltd. H10-C 2BF3X-H10-C 2BF3XH10C h10 c

PDF Viewing Options

Not Your Device? Search For Manuals or Datasheets below:


File Info : application/pdf, 33 Pages, 1.93MB

Document DEVICE REPORTGetApplicationAttachment.html?id=7309009
Report No.: ET-24040220E

TEST REPORT

Applicant: Address of Applicant: Manufacturer/Factory: Address of Manufacturer Product Name:
Model No.:
Trade Mark: FCC ID: Applicable standards: Date of Test: Date of report issued:

Dongguan Mingqin Xin Electronics Co., Ltd. Building 3, No.6 Yongsheng North Road, Fenggang Town, Dongguan City, Guangdong Province Dongguan Mingqin Xin Electronics Co., Ltd. Building 3, No.6 Yongsheng North Road, Fenggang Town, Dongguan City, Guangdong Province Selfie Stick H10-C,H10,H10S,KT02,KT02S,H14,H14SH18,H18S,ES-A110,ESA111,ES-A130,ES-A131,ES-A180,ES-A181,ES-A210,ES-A211,ESB180,ES-B181,ES-B210,ES-B211,ES-A110S,ES-A111S,ESA130S,ES-A131S,ES-A180S,ES-A181S,ES-A210S,ES-A211S,ESB180S,ES-B181S,ES-B210S,ES-B211S,ES-A110D,ES-A111D,ESA130D,ES-A131D,ES-A180D,ES-A181D,ES-A210D,ES-A211D,ESB180D,ES-B181D,ES-B210D,ES-B211D N/A
2BF3X-H10-C
FCC CFR Title 47 Part 15 Subpart C Section 15.247
Mar.30,2024-Apr.18,2024
May.06,2024

Remark:
The results shown in this test report refer only to the sample(s) tested, this test report cannot be reproduced, except in full without prior written permission of the company.
The report would be invalid without specific stamp of test institute and the signatures of compiler and approver

Prepared By
Shenzhen ETR Standard Technology Co., Ltd.
Address: No.103, No.10, Phase I, Zone 3, Xinxing Industrial Park, Xinhe, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China

Compiled by:

Reviewed by:

Approved by:

Project Engineer

Project Manager

Authorized Signature

This test report is valid for the tested samples only. It cannot be reproduced except in full without prior written consent of Shenzhen ETR Standard Technology Co., Ltd.

Report No. ET-24040220E

- Page 2 of 33 -

Report No.: ET-24040220E

Report Revision History
Description Original

Issue Date May.06,2024

Tel:(86-755) 85259392

Email:[email protected]

Web: www.etrlab.cn

No.103, No.10, Phase I, Zone 3, Xinxing Industrial Park, Xinhe, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China

- Page 3 of 33 -

Report No.: ET-24040220E

Contents
Page
1. TEST SUMMARY ......................................................................................................................................4
2. GENERAL INFORMATION .......................................................................................................................5
2.1 GENERAL DESCRIPTION OF EUT .................................................................................................................5 2.2 TEST MODE ................................................................................................................................................7 2.3 DESCRIPTION OF SUPPORT UNITS ...............................................................................................................7 2.4 DEVIATION FROM STANDARDS .....................................................................................................................7 2.5 ABNORMALITIES FROM STANDARD CONDITIONS ....................................................................................7 2.6 TEST FACILITY............................................................................................................................................7 2.7 TEST LOCATION..........................................................................................................................................7 2.8 ADDITIONAL INSTRUCTIONS .........................................................................................................................7
3. TEST INSTRUMENTS LIST ......................................................................................................................8
4. TEST RESULTS AND MEASUREMENT DATA .......................................................................................9
4.1 ANTENNA REQUIREMENT .............................................................................................................................9 4.2 CONDUCTED EMISSIONS ...........................................................................................................................10 4.3 DUTY CYCLE .............................................................................................................................................13 4.4 CONDUCTED OUTPUT POWER ...................................................................................................................15 4.5 6DB BANDWIDTH ......................................................................................................................................16 4.6 POWER SPECTRAL DENSITY......................................................................................................................18 4.7 BAND EDGES ............................................................................................................................................20
Conducted Emission Method ...................................................................................................................20 Radiated Emission Method ......................................................................................................................21 4.8 SPURIOUS EMISSION.................................................................................................................................23 Conducted Emission Method ...................................................................................................................23 Radiated Emission Method ......................................................................................................................25
5. TEST SETUP PHOTO .............................................................................................................................33
6. EUT CONSTRUCTIONAL DETAILS.......................................................................................................33

Tel:(86-755) 85259392

Email:[email protected]

Web: www.etrlab.cn

No.103, No.10, Phase I, Zone 3, Xinxing Industrial Park, Xinhe, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China

- Page 4 of 33 -

Report No.: ET-24040220E

1. Test Summary

Test Item

Section

Antenna requirement

FCC part 15.203/15.247 (c)

AC Power Line Conducted Emission

FCC part 15.207

Conducted Peak Output Power

FCC part 15.247 (b)(3)

6dB Bandwidth

FCC part 15.247 (a)(2)

Power Spectral Density

FCC part 15.247 (e)

Band Edge

FCC part 15.247(d)

Spurious Emission

FCC part 15.205/15.209

Remarks:

1. Pass: The EUT complies with the essential requirements in the standard.

2. Test according to ANSI C63.10:2013

Result Pass Pass Pass Pass Pass Pass Pass

Test by /
Carr kang Yvan Fan Yvan Fan Yvan Fan Yvan Fan Carr kang

3. Note: Compliance determination rules 1).The Compliance determination of test results does not take into account measurement uncertainty.
Measurement results are determined based on regulatory limitations or requirements specified by the applicant/manufacturer. If measurement uncertainty is taken into account, the applicant/manufacturer will bear all possible risks of non-compliance. 2).The measurement uncertainty please refer to each test result in the "Measurement Uncertainty"
Measurement Uncertainty

Test Item

Uncertainty Criterion Measurement Uncertainty Notes

Occupied Channel Bandwidth

±5%

±0.55%

(1)

RF output power, conducted

±1.5dB

±0.99dB

(1)

Power Spectral Density, conducted

±3dB

±0.61dB

(1)

Unwanted Emissions, conducted

±3dB

±0.64dB

(1)

AC Power Line Conducted Emission

±6dB

± 2.64 dB

(1)

Radiated emissions Below 1GHz

±6dB

±4.32 dB

(1)

Radiated emissions Above 1GHz

±6dB

±4.56dB

(1)

Note (1): The measurement uncertainty is for coverage factor of k=2 and a level of confidence of 95%.

Tel:(86-755) 85259392

Email:[email protected]

Web: www.etrlab.cn

No.103, No.10, Phase I, Zone 3, Xinxing Industrial Park, Xinhe, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China

- Page 5 of 33 -

Report No.: ET-24040220E

2. General Information

2.1 General Description of EUT

Product Name:

Selfie Stick

Model No.:
Test Model: Difference of model(s) Hardware version:

H10,H10S,KT02,KT02S,H14,H14SH18,H18S,ES-A110,ES-A111,ESA130,ES-A131,ES-A180,ES-A181,ES-A210,ES-A211,ES-B180,ESB181,ES-B210,ES-B211,ES-A110S,ES-A111S,ES-A130S,ES-A131S, ES-A180S,ES-A181S,ES-A210S,ES-A211S,ES-B180S,ES-B181S,ESB210S,ES-B211S,ES-A110D,ES-A111D,ES-A130D,ES-A131D,ESA180D,ES-A181D,ES-A210D,ES-A211D,ES-B180D,ES-B181D,ESB210D,ES-B211D
H10-C
All the model are the same circuit and RF module, except the model names and colors
N/A

Software version:

N/A

Sample(s) Status

Engineer sample

Operation Frequency:

2402MHz~2480MHz

Channel Numbers:

40

Channel separation: Modulation technology:

2MHz GFSK

Battery: Antenna Type:
Antenna gain: Power supply:

DC 3.7V 200mAh
PCB Antenna 0.31dBi(Declare by applicant) Note: Antenna information is provided by applicant, Testing lab is not responsible for the accuracy of the information. DC 3.7V from battery

Tel:(86-755) 85259392

Email:[email protected]

Web: www.etrlab.cn

No.103, No.10, Phase I, Zone 3, Xinxing Industrial Park, Xinhe, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China

- Page 6 of 33 -

Report No.: ET-24040220E

Operation Frequency each of channel

Channel Frequency Channel Frequency Channel Frequency Channel Frequency

1

2402 MHz

11

2422 MHz

21

2442 MHz

31

2462 MHz

2

2404 MHz

12

2424 MHz

22

2444 MHz

32

2464 MHz

3

2406 MHz

13

2426 MHz

23

2446 MHz

33

2466 MHz

4

2408 MHz

14

2428 MHz

24

2448 MHz

34

2468 MHz

5

2410 MHz

15

2430 MHz

25

2450 MHz

35

2470 MHz

6

2412 MHz

16

2432 MHz

26

2452 MHz

36

2472 MHz

7

2414 MHz

17

2434 MHz

27

2454 MHz

37

2474 MHz

8

2416 MHz

18

2436 MHz

28

2456 MHz

38

2476 MHz

9

2418 MHz

19

2438 MHz

29

2458 MHz

39

2478 MHz

10

2420 MHz

20

2440 MHz

30

2460 MHz

40

2480 MHz

Note:

In section 15.31(m), regards to the operating frequency range over 10 MHz, the Lowest frequency, the middle frequency, and the highest frequency of channel were selected to perform the test, and the selected channel see below:

Test channel

Frequency (MHz)

Lowest channel Middle channel Highest channel

2402MHz 2440MHz 2480MHz

Tel:(86-755) 85259392

Email:[email protected]

Web: www.etrlab.cn

No.103, No.10, Phase I, Zone 3, Xinxing Industrial Park, Xinhe, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China

- Page 7 of 33 -

Report No.: ET-24040220E

2.2 Test mode

Transmitting mode

Keep the EUT in continuously transmitting mode

EUT was test with maximum power control level.

Remark: For battery operated equipment, the EUT was performed using a new DC 3.7V battery.

2.3 Description of Support Units

No.

Description

1

Adapter

Manufacturer Xiao mi

Model 5V/1A

Serial Number /

2.4 Deviation from Standards None.

2.5 Abnormalities from Standard Conditions

None.

2.6 Test Facility

Test laboratory:

Shenzhen ETR Standard Technology Co., Ltd.

CNAS Registration Number: L11864

A2LA Certificate Number:

6640.01

FCC Designation Number: CN1326 FCC Test Firm Registration: 183064

2.7 Test Location

All tests were performed at:

Laboratory location:

No.103, No.10, Phase I, Zone 3, Xinxing Industrial Park, Xinhe, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China

Telephone:

+86 755 85259392

Fax:

+86 755 27219460

2.8 Additional Instructions

Test Software

WS8000 RF Test_V0.0.4_20220402.exe

Power level setup

Default

Tel:(86-755) 85259392

Email:[email protected]

Web: www.etrlab.cn

No.103, No.10, Phase I, Zone 3, Xinxing Industrial Park, Xinhe, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China

- Page 8 of 33 -

Report No.: ET-24040220E

3. Test Instruments list

Item

Equipment name

Manufacturer

Model

Serial No.

1

EMI Test Receiver

Rohde&schwarz

ESCI7

100605

2

EMI Test Receiver

Rohde&schwarz

ESCI3

102696

3

Loop Antenna

schwarabeck

FMZB 1519 B

FMZB 1519 B

4

Broadband antenna

schwarabeck

VULB9168

1064

5

Horn antenna

schwarabeck BBHA9120D 9120D-1145

6

amplifier

EMtrace

RP01A

50117

7

Artificial power network

schwarabeck

NSLK8127

8127483

8

Artificial power network

ETS

3186/2NM

1132

9

10dB attenuator

HUBER+SUHNE R

10dB

/

10

amplifier

Space-Dtronics

EWLAN0118 G-P40

19113001

11

Filter

Xingbo

XBLBQGTA19

210410-3-1

12

Spectrum analyzer

KEYSIGHT

N9020A MY55370280

Calibration date
2024.3.012 2024.3.012 2024.3.19 2024.3.19 2024.3.19 2024.3.012 2024.3.012 2024.3.012 2024.3.012 2024.3.012
2024.3.012
2024.3.012

Due date 2025.3.11 2025.3.11 2026.3.18 2026.3.18 2026.3.18 2025.3.11 2025.3.11 2025.3.11 2025.3.11 2025.3.11
2025.3.11
2025.3.11

13

Power detector box MWRFtest

MW100-PSB MW201020JYT 2024.3.012 2025.3.11

14

Power meter

Rohde&Schwarz NRP-Z11

1138.3004.02117725-vh

2024.3.012 2025.3.11

Note: the calibration interval of the above test instruments is 12 or 24 months and the calibrations are traceable to international system unit (SI).

Software Name
RF test software

Manufacturer MWRFtest

Model MTS 8310

Version V2.0.0.0

Conducted test software

EZ-EMC

Farad

Ver.EMC-CON 3A1.1

Radiated test software

EZ-EMC

Farad

Ver.FA-03A2 RE

Tel:(86-755) 85259392

Email:[email protected]

Web: www.etrlab.cn

No.103, No.10, Phase I, Zone 3, Xinxing Industrial Park, Xinhe, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China

- Page 9 of 33 -

Report No.: ET-24040220E

4. Test results and Measurement Data
4.1 Antenna requirement
Standard requirement: FCC Part15 C Section 15.203 /247(c)
15.203 requirement:
An intentional radiator shall be designed to ensure that no antenna other than that furnished by the responsible party shall be used with the device. The use of a permanently attached antenna or of an antenna that uses a unique coupling to the intentional radiator, the manufacturer may design the unit so that a broken antenna can be replaced by the user, but the use of a standard antenna jack or electrical connector is prohibited.
15.247(c) (1)(i) requirement:
(i) Systems operating in the 2400-2483.5 MHz band that is used exclusively for fixed. Point-to-point operations may employ transmitting antennas with directional gain greater than 6dBi provided the maximum conducted output power of the intentional radiator is reduced by 1 dB for every 3 dB that the directional gain of the antenna exceeds 6dBi. EUT Antenna: The antenna is PCB antenna, the best case gain of the antenna is 0.31 dBi, reference to the appendix II for details.

Tel:(86-755) 85259392

Email:[email protected]

Web: www.etrlab.cn

No.103, No.10, Phase I, Zone 3, Xinxing Industrial Park, Xinhe, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China

- Page 10 of 33

Report No.: ET-24040220E

-

4.2 Conducted Emissions

Test Requirement: Test Method: Test Frequency Range: Receiver setup: Limit:
Test setup:

FCC Part15 C Section 15.207

ANSI C63.10:2013

150KHz to 30MHz

RBW=9KHz, VBW=30KHz, Sweep time=auto

Frequency range (MHz)

Limit (dBuV)

Quasi-peak

Average

0.15-0.5

66 to 56*

56 to 46*

0.5-5

56

46

5-30

60

50

* Decreases with the logarithm of the frequency.

Test procedure:

1. The E.U.T and simulators are connected to the main power through a line impedance stabilization network (L.I.S.N.). This provides a 50ohm/50uH coupling impedance for the measuring equipment.

2. The peripheral devices are also connected to the main power through a LISN that provides a 50ohm/50uH coupling impedance with 50ohm termination. (Please refer to the block diagram of the test setup and photographs).

3. Both sides of A.C. line are checked for maximum conducted interference. In order to find the maximum emission, the relative positions of equipment and all of the interface cables must be changed according to ANSI C63.10:2013 on conducted measurement.

Test Instruments:

Refer to section 3.0 for details

Test mode:

Refer to section 2.2 for details

Test environment:

Temp.:

25.9C

Humid.: 56%

Press.:

1012mbar

Test voltage:

AC 120V, 60Hz

Test results:

Pass

Remark: 1. Both high voltage and low voltage have been tested, and the report only shows the worst case data with
AC 120V/60Hz. 2. All mode have been tested, the report only shows the worst mode (2440MHz) data.

Tel:(86-755) 85259392

Email:[email protected]

Web: www.etrlab.cn

No.103, No.10, Phase I, Zone 3, Xinxing Industrial Park, Xinhe, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China

Measurement data Line:

- Page 11 of 33

Report No.: ET-24040220E

Tel:(86-755) 85259392

Email:[email protected]

Web: www.etrlab.cn

No.103, No.10, Phase I, Zone 3, Xinxing Industrial Park, Xinhe, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China

Neutral:

- Page 12 of 33

Report No.: ET-24040220E

Notes: 1. An initial pre-scan was performed on the line and neutral lines with peak detector. 2. Quasi-Peak and Average measurement were performed at the frequencies with maximized peak emission. 3. Level =Receiver Read level + Factor (Factor= LISN Factor + Cable Loss+ Attenuator Factor) 4. If the average limit is met when using a quasi-peak detector receiver, the EUT shall be deemed to meet
both limits and measurement with the average detector receiver is unnecessary.

Tel:(86-755) 85259392

Email:[email protected]

Web: www.etrlab.cn

No.103, No.10, Phase I, Zone 3, Xinxing Industrial Park, Xinhe, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China

-
4.3 Duty cycle
Test Method : Limit: Test setup:

- Page 13 of 33
ANSI C63.10:2013 /

Report No.: ET-24040220E

Test Instruments: Test mode: Test environment: Test voltage: Test results:
Measurement Result
Test channel Lowest Middle Highest

Refer to section 3.0 for details Refer to section 2.2 for details Temp.: 24.9C DC 3.7V Pass
Duty Cycle (%) 100 100 100

Humid.: 51%RH

Tel:(86-755) 85259392

Email:[email protected]

Web: www.etrlab.cn

No.103, No.10, Phase I, Zone 3, Xinxing Industrial Park, Xinhe, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China

Test plot as follows:

- Page 14 of 33

Report No.: ET-24040220E

Lowest channel

Middle channel

Highest channel

Tel:(86-755) 85259392

Email:[email protected]

Web: www.etrlab.cn

No.103, No.10, Phase I, Zone 3, Xinxing Industrial Park, Xinhe, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China

- Page 15 of 33

Report No.: ET-24040220E

-

4.4 Conducted Output Power

Test Requirement : Test Method : Limit: Test setup:

FCC Part15 C Section 15.247 (b)(3) ANSI C63.10:2013 and KDB558074 D01 15.247 Meas Guidance v05r02 30dBm

Test Instruments: Test mode: Test environment: Test voltage: Test results:

Refer to section 3.0 for details Refer to section 2.2 for details Temp.: 24.9C DC 3.7V Pass

Humid.: 51%RH

Measurement Result
Test channel Lowest Middle Highest

Output Power (dBm) -1.15 -0.30 -0.48

Limit(dBm) 30.00

Result Pass

Tel:(86-755) 85259392

Email:[email protected]

Web: www.etrlab.cn

No.103, No.10, Phase I, Zone 3, Xinxing Industrial Park, Xinhe, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China

-
4.5 6dB Bandwidth
Test Requirement : Test Method : Limit: Test setup:

- Page 16 of 33

Report No.: ET-24040220E

FCC Part15 C Section 15.247 (a)(2) ANSI C63.10:2013 and KDB558074 D01 15.247 Meas Guidance v05r02 >500KHz

Test Instruments: Test mode: Test environment: Test voltage: Test results:

Refer to section 3.0 for details Refer to section 2.2 for details Temp.: 24.9C DC 3.7V Pass

Humid.: 51%RH

Measurement Result

Test channel Lowest Middle Highest

6dB Bandwidth (MHz) 0.7556 0.7621 0.7727

Limit(KHz) >500

Result Pass

Tel:(86-755) 85259392

Email:[email protected]

Web: www.etrlab.cn

No.103, No.10, Phase I, Zone 3, Xinxing Industrial Park, Xinhe, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China

Test plot as follows:

- Page 17 of 33

Report No.: ET-24040220E

Lowest channel

Middle channel

Highest channel

Tel:(86-755) 85259392

Email:[email protected]

Web: www.etrlab.cn

No.103, No.10, Phase I, Zone 3, Xinxing Industrial Park, Xinhe, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China

- Page 18 of 33

Report No.: ET-24040220E

-

4.6 Power Spectral Density

Test Requirement: Test Method: Limit: Test setup:

FCC Part15 C Section 15.247 (e) ANSI C63.10:2013 and KDB558074 D01 15.247 Meas Guidance v05r02 8dBm/3kHz

Test Instruments: Test mode: Test environment: Test voltage: Test results:

Refer to section 3.0 for details Refer to section 2.2 for details Temp.: 24.9C DC 3.7V Pass

Humid.: 51%RH

Measurement Result

Test channel
Lowest Middle Highest

Power Spectral Density (dBm/3kHz) -1.233
-0.384
-0.561

Limit(dBm/3kHz) 8.00

Result Pass

Tel:(86-755) 85259392

Email:[email protected]

Web: www.etrlab.cn

No.103, No.10, Phase I, Zone 3, Xinxing Industrial Park, Xinhe, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China

Test plot as follows:

- Page 19 of 33

Report No.: ET-24040220E

Lowest channel

Middle channel

Highest channel

Tel:(86-755) 85259392

Email:[email protected]

Web: www.etrlab.cn

No.103, No.10, Phase I, Zone 3, Xinxing Industrial Park, Xinhe, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China

- Page 20 of 33

Report No.: ET-24040220E

-

4.7 Band edges

Conducted Emission Method

Test Requirement: Test Method: Limit:
Test setup:

FCC Part15 C Section 15.247 (d)
KDB558074 D01 DTS Meas Guidance v05or02
In any 100 kHz bandwidth outside the frequency band in which the spread spectrum intentional radiator is operating, the radio frequency power that is produced by the intentional radiator shall be at least 20 dB below that in the 100 kHz bandwidth within the band that contains the highest level of the desired power, based on either an RF conducted or a radiated measurement.

Test Instruments: Test mode: Test environment: Test voltage: Test results:
Test plot as follows:

Refer to section 3.0 for details Refer to section 2.2 for details Temp.: 24.9C DC 3.7V Pass

Humid.: 51%RH

Lowest channel

Highest channel

Tel:(86-755) 85259392

Email:[email protected]

Web: www.etrlab.cn

No.103, No.10, Phase I, Zone 3, Xinxing Industrial Park, Xinhe, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China

- Page 21 of 33

Report No.: ET-24040220E

-

Radiated Emission Method
Test Requirement: Test Method: Test Frequency Range: Test site: Receiver setup:
Limit:
Test setup:

FCC Part15 C Section 15.209 and 15.205

ANSI C63.10: 2013

All of the restrict bands were tested, only the worst band's (2310MHz to

2500MHz) data was showed.

Measurement Distance: 3m

Frequency

Detector

RBW

VBW

Value

Above 1GHz

Peak Average

1MHz 1MHz

3MHz 3MHz

Peak Average

Frequency

Limit (dBuV/m @3m)

Value

Above 1GHz

54.00 74.00

Average Peak

Test Procedure:
Test Instruments: Test mode: Test environment: Test voltage: Test results:

1. The EUT was placed on the top of a rotating table 1.5 meters above the ground at a 3 meter camber. The table was rotated 360 degrees to determine the position of the highest radiation.
2. The EUT was set 3 meters away from the interference-receiving antenna, which was mounted on the top of a variable-height antenna tower.
3. The antenna height is varied from one meter to four meters above the ground to determine the maximum value of the field strength. Both horizontal and vertical polarizations of the antenna are set to make the measurement.
4. For each suspected emission, the EUT was arranged to its worst case and then the antenna was tuned to heights from 1 meter to 4 meters and the rota table was turned from 0 degrees to 360 degrees to find the maximum reading.
5. The test-receiver system was set to Peak Detect Function and Specified Bandwidth with Maximum Hold Mode.
6. If the emission level of the EUT in peak mode was 10dB lower than the limit specified, then testing could be stopped and the peak values of the EUT would be reported. Otherwise the emissions that did not have 10dB margin would be re-tested one by one using peak, quasi-peak or average method as specified and then reported in a data sheet.
7. The radiation measurements are performed in X, Y, Z axis positioning. And found the Y axis positioning which it is worse case, only the test worst case mode is recorded in the report.
Refer to section 3.0 for details Refer to section 2.2 for details

Temp.: 24.9C

Humid.: 51%RH

DC 3.7V

Pass

Tel:(86-755) 85259392

Email:[email protected]

Web: www.etrlab.cn

No.103, No.10, Phase I, Zone 3, Xinxing Industrial Park, Xinhe, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China

- Page 22 of 33

Report No.: ET-24040220E

-

Measurement Result:

Test channel:

Peak value:

Frequency (MHz)

Read Level (dBuV)

2310.00

62.62

2390.00

65.98

2310.00

62.09

2390.00

65.22

Average value:

Frequency (MHz)

Read Level (dBuV)

2310.00

51.88

2390.00

56.38

2310.00

52.89

2390.00

55.62

Antenna Factor (dB/m) 27.40 27.10 27.40 27.10
Antenna Factor (dB/m) 27.40 27.10 27.40 27.10

Cable Loss (dB) 3.43 3.43 3.43 3.43
Cable Loss (dB) 3.43 3.43 3.43 3.43

Lowest

Preamp Factor (dB)
45.40 45.40 45.40 45.40

Level Limit Line (dBuV/m) (dBuV/m)

48.05 51.11 47.52 50.35

74.00 74.00 74.00 74.00

Over Limit (dB)
-25.95 -22.89 -26.48 -23.65

Polarization
Horizontal Horizontal
Vertical Vertical

Preamp Factor (dB)
45.40 45.40 45.40 45.40

Level Limit Line (dBuV/m) (dBuV/m)

37.31 41.51 38.32 40.75

54.00 54.00 54.00 54.00

Over Limit (dB)
-16.69 -12.49 -15.68 -13.26

Polarization
Horizontal Horizontal
Vertical Vertical

Test channel:

Highest

Peak value:

Frequency (MHz)

Read Level (dBuV)

2483.50

68.00

2500.00

61.89

2483.50

65.46

2500.00

62.02

Average value:

Antenna Factor (dB/m)
27.80 27.80 27.80 27.80

Cable Loss (dB)
3.56 3.56 3.56 3.56

Preamp Factor (dB)
45.40 45.40 45.40 45.40

Level Limit Line (dBuV/m) (dBuV/m)

53.96 47.85 51.42 47.98

74.00 74.00 74.00 74.00

Over Limit (dB)
-20.04 -26.15 -22.58 -26.02

Polarization
Horizontal Horizontal
Vertical Vertical

Frequency (MHz)

Read Level (dBuV)

Antenna Factor (dB/m)

Cable Loss (dB)

Preamp Factor (dB)

Level Limit Line (dBuV/m) (dBuV/m)

Over Limit (dB)

Polarization

2483.50

55.56

27.80

3.56

45.40

41.52

54.00

-12.48 Horizontal

2500.00

52.75

27.80

3.56

45.40

38.71

54.00

-15.29 Horizontal

2483.50

54.15

27.80

3.56

45.40

40.11

54.00

-13.90

Vertical

2500.00

51.85

27.80

3.56

45.40

37.81

54.00

-16.19

Vertical

Remarks: 1. Level = Read level + Antenna Factor + Cable Loss ­ Preamplifier Factor 2. Emissions more than 20 dB below the limit do not need to be reported. 3. The pre-test were performed on lowest, middle and highest frequencies, only the worst case's (lowest
and highest frequencies) data was showed.

Tel:(86-755) 85259392

Email:[email protected]

Web: www.etrlab.cn

No.103, No.10, Phase I, Zone 3, Xinxing Industrial Park, Xinhe, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China

- Page 23 of 33

Report No.: ET-24040220E

-

4.8 Spurious Emission

Conducted Emission Method

Test Requirement:

FCC Part15 C Section 15.247 (d)

Test Method:

KDB558074 D01 DTS Meas Guidance v05or02

Limit:

In any 100 kHz bandwidth outside the frequency band in which the spread spectrum intentional radiator is operating, the radio frequency power that is produced by the intentional radiator shall be at least 20 dB below that in the 100 kHz bandwidth within the band that contains the highest level of the desired power, based on either an RF conducted or a radiated measurement.

Test setup:

Test Instruments: Test mode: Test environment: Test voltage:
Test results:

Refer to section 3.0 for details Refer to section 2.2 for details Temp.: 24.9C DC 3.7V Pass

Humid.: 51%RH

Tel:(86-755) 85259392

Email:[email protected]

Web: www.etrlab.cn

No.103, No.10, Phase I, Zone 3, Xinxing Industrial Park, Xinhe, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China

-
Test plot as follows: Lowest channel

- Page 24 of 33

Report No.: ET-24040220E

Middle channel

30MHz~26.5GHz

Highest channel

30MHz~26.5GHz

30MHz~26.5GHz

Tel:(86-755) 85259392

Email:[email protected]

Web: www.etrlab.cn

No.103, No.10, Phase I, Zone 3, Xinxing Industrial Park, Xinhe, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China

- Page 25 of 33

Report No.: ET-24040220E

-

Radiated Emission Method
Test Requirement: Test Method: Test Frequency Range: Test site: Receiver setup:
Limit:
Test setup:

FCC Part15 C Section 15.209

ANSI C63.10: 2013

9kHz to 25GHz

Measurement Distance: 3m

Frequency

Detector

RBW

VBW

Value

9KHz-150KHz Quasi-peak 200Hz 600Hz Quasi-peak

150KHz-30MHz Quasi-peak 9KHz 30KHz Quasi-peak

30MHz-1GHz Quasi-peak 120KHz 300KHz Quasi-peak

Above 1GHz

Peak Peak

1MHz 1MHz

3MHz 10Hz

Peak Average

Frequency

Limit (uV/m)

Value

Measurement Distance

0.009MHz-0.490MHz 2400/F(KHz)

QP

300m

0.490MHz-1.705MHz 24000/F(KHz)

QP

300m

1.705MHz-30MHz

30

QP

30m

30MHz-88MHz

100

QP

88MHz-216MHz

150

QP

216MHz-960MHz

200

QP

3m

960MHz-1GHz

500

QP

Above 1GHz

500 5000

Average Peak

For radiated emissions from 9kHz to 30MHz

For radiated emissions from 30MHz to1GHz

For radiated emissions above 1GHz

Tel:(86-755) 85259392

Email:[email protected]

Web: www.etrlab.cn

No.103, No.10, Phase I, Zone 3, Xinxing Industrial Park, Xinhe, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China

- Page 26 of 33

Report No.: ET-24040220E

-

Test Procedure:

1. The EUT was placed on the top of a rotating table (0.8m for below 1G and 1.5m for above 1G) above the ground at a 3 meter camber. The table was rotated 360 degrees to determine the position of the highest radiation.
2. The EUT was set 3 meters away from the interference-receiving antenna, which was mounted on the top of a variable-height antenna tower.

3. The antenna height is varied from one meter to four meters above the ground to determine the maximum value of the field strength. Both horizontal and vertical polarizations of the antenna are set to make the measurement.

4. For each suspected emission, the EUT was arranged to its worst case and then the antenna was tuned to heights from 1 meter to 4 meters and the rota table was turned from 0 degrees to 360 degrees to find the maximum reading.

5. The test-receiver system was set to Peak Detect Function and Specified Bandwidth with Maximum Hold Mode.

6. If the emission level of the EUT in peak mode was 10dB lower than the limit specified, then testing could be stopped and the peak values of the EUT would be reported. Otherwise the emissions that did not have 10dB margin would be re-tested one by one using peak, quasi-peak or average method as specified and then reported in a data sheet.

Test Instruments:

Refer to section 3.0 for details

Test mode:

Refer to section 2.2 for details

Test voltage:

DC 3.7V

Test environment:

Temp.:

24.9C

Humid.: 51%

Press.:

1012mbar

Test results:

Pass

Remarks:

1. The report only shows the worst mode.

2. Pre-scan all kind of the place mode (X-axis, Y-axis, Z-axis), and found the Y-axis which it is worse case.

Tel:(86-755) 85259392

Email:[email protected]

Web: www.etrlab.cn

No.103, No.10, Phase I, Zone 3, Xinxing Industrial Park, Xinhe, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China

- Page 27 of 33

Report No.: ET-24040220E

-

Measurement Result:  9kHz~30MHz

The emission from 9 kHz to 30MHz was pre-tested and found the result was 20dB lower than the limit, and according to 15.31(o) & RSS-Gen 6.13, the test result no need to reported.

Tel:(86-755) 85259392

Email:[email protected]

Web: www.etrlab.cn

No.103, No.10, Phase I, Zone 3, Xinxing Industrial Park, Xinhe, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China

- Page 28 of 33

Report No.: ET-24040220E

-

 Below 1GHz All mode has been tested, the report only shows the worst mode (2440MHz) data.
Vertical:

Tel:(86-755) 85259392

Email:[email protected]

Web: www.etrlab.cn

No.103, No.10, Phase I, Zone 3, Xinxing Industrial Park, Xinhe, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China

Horizontal:

- Page 29 of 33

Report No.: ET-24040220E

Remarks: Level =Receiver Reading + Factor Factor= Antenna Factor + Cable Factor ­ Preamplifier Factor

Tel:(86-755) 85259392

Email:[email protected]

Web: www.etrlab.cn

No.103, No.10, Phase I, Zone 3, Xinxing Industrial Park, Xinhe, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China

- Page 30 of 33

Report No.: ET-24040220E

-

 Above 1GHz

Test channel:

Peak value:
Frequency (MHz)

Read Level (dBuV)

4804.00

55.82

Antenna Factor (dB/m)
32.10

Lowest

Cable Loss (dB)
5.96

Preamp Factor (dB)
45.70

Level (dBuV/m)
48.18

7206.00

53.44

36.10

6.86

45.50

50.90

9608.00

51.40

38.30

8.25

46.20

51.75

12010.00

*

--

--

--

--

14412.00

*

--

--

--

--

4804.00

54.23

32.10

5.96

45.70

46.59

7206.00

53.04

36.10

6.86

45.50

50.50

9608.00

50.04

38.30

8.25

46.20

50.39

12010.00

*

--

--

--

--

14412.00

*

Average value:

Frequency (MHz)

Read Level (dBuV)

--
Antenna Factor (dB/m)

--

--

--

Cable Loss (dB)

Preamp Factor (dB)

Level (dBuV/m)

4804.00

44.64

32.10

5.96

45.70

37.00

7206.00

41.00

36.10

6.86

45.50

38.46

9608.00

39.74

38.30

8.25

46.20

40.09

12010.00

*

--

--

--

--

14412.00

*

--

--

--

--

4804.00

45.00

32.10

5.96

45.70

37.36

7206.00

43.06

36.10

6.86

45.50

40.52

9608.00

38.99

38.30

8.25

46.20

39.34

12010.00

*

--

--

--

--

14412.00

*

--

--

--

--

Remarks:

1. Level = Read level + Antenna Factor + Cable Loss ­ Preamplifier Factor

2. "*", means this data is the too weak instrument of signal is unable to test.

3. Emissions more than 20 dB below the limit do not need to be reported.

Limit Line (dBuV/m)
74.00 74.00 74.00 74.00 74.00 74.00 74.00 74.00 74.00 74.00
Limit Line (dBuV/m)
54.00 54.00 54.00 54.00 54.00 54.00 54.00 54.00 54.00 54.00

Over Limit (dB) -25.82 -23.10 -22.25
---27.41 -23.50 -23.61 ---

polarization
Vertical Vertical Vertical Vertical Vertical Horizontal Horizontal Horizontal Horizontal Horizontal

Over Limit (dB) -17.00 -15.54 -13.91
---16.64 -13.48 -14.66 ---

polarization
Vertical Vertical Vertical Vertical Vertical Horizontal Horizontal Horizontal Horizontal Horizontal

Tel:(86-755) 85259392

Email:[email protected]

Web: www.etrlab.cn

No.103, No.10, Phase I, Zone 3, Xinxing Industrial Park, Xinhe, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China

- Page 31 of 33

Report No.: ET-24040220E

-

Test channel:

Peak value:
Frequency (MHz)

Read Level (dBuV)

4880.00

54.81

Antenna Factor (dB/m)
32.10

Middle

Cable Loss (dB)
5.96

Preamp Factor (dB)
45.70

Level (dBuV/m)
47.17

Limit Line (dBuV/m)
74.00

7320.00

53.15

36.80

6.86

45.50

51.31

74.00

9760.00

51.15

38.40

8.25

46.20

51.60

74.00

12200.00

*

--

--

--

--

74.00

14640.00

*

--

--

--

--

74.00

4880.00

55.07

32.10

5.96

45.70

47.43

74.00

7320.00

53.48

36.80

6.86

45.50

51.64

74.00

9760.00

49.94

38.40

8.25

46.20

50.39

74.00

12200.00

*

--

--

--

--

74.00

14640.00

*

Average value:

Frequency (MHz)

Read Level (dBuV)

4880.00

45.07

--
Antenna Factor (dB/m) 32.10

--

--

--

74.00

Cable Loss (dB)
5.96

Preamp Factor (dB)
45.70

Level (dBuV/m)
37.43

Limit Line (dBuV/m)
54.00

7320.00

40.25

36.80

6.86

45.50

38.41

54.00

9760.00

38.70

38.40

8.25

46.20

39.15

54.00

12200.00

*

--

--

--

--

54.00

14640.00

*

--

--

--

--

54.00

4880.00

44.92

32.10

5.96

45.70

37.28

54.00

7320.00

42.68

36.80

6.86

45.50

40.84

54.00

9760.00

39.71

38.40

8.25

46.20

40.16

54.00

12200.00

*

--

--

--

--

54.00

14640.00

*

--

--

--

--

54.00

Remarks:

1. Final Level =Receiver Read level + Antenna Factor + Cable Loss ­ Preamplifier Factor

2. "*", means this data is the too weak instrument of signal is unable to test.

3. Emissions more than 20 dB below the limit do not need to be reported.

Over Limit (dB) -26.83 -22.69 -22.40
---26.57 -22.36 -23.61 ---

polarization
Vertical Vertical Vertical Vertical Vertical Horizontal Horizontal Horizontal Horizontal Horizontal

Over Limit (dB) -16.57 -15.59 -14.85
---16.72 -13.16 -13.84 ---

polarization
Vertical Vertical Vertical Vertical Vertical Horizontal Horizontal Horizontal Horizontal Horizontal

Tel:(86-755) 85259392

Email:[email protected]

Web: www.etrlab.cn

No.103, No.10, Phase I, Zone 3, Xinxing Industrial Park, Xinhe, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China

- Page 32 of 33

Report No.: ET-24040220E

-

Test channel:

Peak value:
Frequency (MHz)

Read Level (dBuV)

4960.00

54.11

Antenna Factor (dB/m)
32.70

Highest

Cable Loss (dB)
5.96

Preamp Factor (dB)
45.70

Level (dBuV/m)
47.07

7440.00

52.62

36.40

6.86

45.50

50.38

9920.00

50.75

38.00

8.25

46.20

50.80

12400.00

*

--

--

--

--

14880.00

*

--

--

--

--

4960.00

53.56

32.70

5.96

45.70

46.52

7440.00

51.91

36.40

6.86

45.50

49.67

9920.00

50.17

38.00

8.25

46.20

50.22

12400.00

*

--

--

--

--

14880.00

*

Average value:

Frequency (MHz)

Read Level (dBuV)

4960.00

43.77

--
Antenna Factor (dB/m) 32.70

--

--

--

Cable Loss (dB)
5.96

Preamp Factor (dB)
45.70

Level (dBuV/m)
36.73

7440.00

40.14

36.40

6.86

45.50

37.90

9920.00

39.15

38.00

8.25

46.20

39.20

12400.00

*

--

--

--

--

14880.00

*

--

--

--

--

4960.00

43.08

32.70

5.96

45.70

36.04

7440.00

40.05

36.40

6.86

45.50

37.81

9920.00

38.01

38.00

8.25

46.20

38.06

12400.00

*

--

--

--

--

14880.00

*

--

--

--

--

Remarks:

1. Level = Read level + Antenna Factor + Cable Loss ­ Preamplifier Factor

2. "*", means this data is the too weak instrument of signal is unable to test.

3. Emissions more than 20 dB below the limit do not need to be reported.

Limit Line (dBuV/m)
74.00 74.00 74.00 74.00 74.00 74.00 74.00 74.00 74.00 74.00
Limit Line (dBuV/m)
54.00 54.00 54.00 54.00 54.00 54.00 54.00 54.00 54.00 54.00

Over Limit (dB) -26.93 -23.62 -23.20
---27.48 -24.33 -23.78 ---

polarization
Vertical Vertical Vertical Vertical Vertical Horizontal Horizontal Horizontal Horizontal Horizontal

Over Limit (dB) -17.27 -16.10 -14.80
---17.96 -16.19 -15.94 ---

polarization
Vertical Vertical Vertical Vertical Vertical Horizontal Horizontal Horizontal Horizontal Horizontal

Tel:(86-755) 85259392

Email:[email protected]

Web: www.etrlab.cn

No.103, No.10, Phase I, Zone 3, Xinxing Industrial Park, Xinhe, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China

- Page 33 of 33 -
5. Test Setup Photo
Reference to the appendix I for details.
6. EUT Constructional Details
Reference to the appendix II for details.
------End------