HD 271 S1
LAB02
Test Report BLE
Dongguan Mingqin Xin Electronics Co., Ltd. H10-C 2BF3X-H10-C 2BF3XH10C h10 c
Not Your Device? Search For Manuals or Datasheets below:
File Info : application/pdf, 33 Pages, 1.93MB
Document DEVICE REPORTGetApplicationAttachment.html?id=7309009Report No.: ET-24040220E TEST REPORT Applicant: Address of Applicant: Manufacturer/Factory: Address of Manufacturer Product Name: Model No.: Trade Mark: FCC ID: Applicable standards: Date of Test: Date of report issued: Dongguan Mingqin Xin Electronics Co., Ltd. Building 3, No.6 Yongsheng North Road, Fenggang Town, Dongguan City, Guangdong Province Dongguan Mingqin Xin Electronics Co., Ltd. Building 3, No.6 Yongsheng North Road, Fenggang Town, Dongguan City, Guangdong Province Selfie Stick H10-C,H10,H10S,KT02,KT02S,H14,H14SH18,H18S,ES-A110,ESA111,ES-A130,ES-A131,ES-A180,ES-A181,ES-A210,ES-A211,ESB180,ES-B181,ES-B210,ES-B211,ES-A110S,ES-A111S,ESA130S,ES-A131S,ES-A180S,ES-A181S,ES-A210S,ES-A211S,ESB180S,ES-B181S,ES-B210S,ES-B211S,ES-A110D,ES-A111D,ESA130D,ES-A131D,ES-A180D,ES-A181D,ES-A210D,ES-A211D,ESB180D,ES-B181D,ES-B210D,ES-B211D N/A 2BF3X-H10-C FCC CFR Title 47 Part 15 Subpart C Section 15.247 Mar.30,2024-Apr.18,2024 May.06,2024 Remark: The results shown in this test report refer only to the sample(s) tested, this test report cannot be reproduced, except in full without prior written permission of the company. The report would be invalid without specific stamp of test institute and the signatures of compiler and approver Prepared By Shenzhen ETR Standard Technology Co., Ltd. Address: No.103, No.10, Phase I, Zone 3, Xinxing Industrial Park, Xinhe, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China Compiled by: Reviewed by: Approved by: Project Engineer Project Manager Authorized Signature This test report is valid for the tested samples only. It cannot be reproduced except in full without prior written consent of Shenzhen ETR Standard Technology Co., Ltd. Report No. ET-24040220E - Page 2 of 33 - Report No.: ET-24040220E Report Revision History Description Original Issue Date May.06,2024 Tel:(86-755) 85259392 Email:[email protected] Web: www.etrlab.cn No.103, No.10, Phase I, Zone 3, Xinxing Industrial Park, Xinhe, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China - Page 3 of 33 - Report No.: ET-24040220E Contents Page 1. TEST SUMMARY ......................................................................................................................................4 2. GENERAL INFORMATION .......................................................................................................................5 2.1 GENERAL DESCRIPTION OF EUT .................................................................................................................5 2.2 TEST MODE ................................................................................................................................................7 2.3 DESCRIPTION OF SUPPORT UNITS ...............................................................................................................7 2.4 DEVIATION FROM STANDARDS .....................................................................................................................7 2.5 ABNORMALITIES FROM STANDARD CONDITIONS ....................................................................................7 2.6 TEST FACILITY............................................................................................................................................7 2.7 TEST LOCATION..........................................................................................................................................7 2.8 ADDITIONAL INSTRUCTIONS .........................................................................................................................7 3. TEST INSTRUMENTS LIST ......................................................................................................................8 4. TEST RESULTS AND MEASUREMENT DATA .......................................................................................9 4.1 ANTENNA REQUIREMENT .............................................................................................................................9 4.2 CONDUCTED EMISSIONS ...........................................................................................................................10 4.3 DUTY CYCLE .............................................................................................................................................13 4.4 CONDUCTED OUTPUT POWER ...................................................................................................................15 4.5 6DB BANDWIDTH ......................................................................................................................................16 4.6 POWER SPECTRAL DENSITY......................................................................................................................18 4.7 BAND EDGES ............................................................................................................................................20 Conducted Emission Method ...................................................................................................................20 Radiated Emission Method ......................................................................................................................21 4.8 SPURIOUS EMISSION.................................................................................................................................23 Conducted Emission Method ...................................................................................................................23 Radiated Emission Method ......................................................................................................................25 5. TEST SETUP PHOTO .............................................................................................................................33 6. EUT CONSTRUCTIONAL DETAILS.......................................................................................................33 Tel:(86-755) 85259392 Email:[email protected] Web: www.etrlab.cn No.103, No.10, Phase I, Zone 3, Xinxing Industrial Park, Xinhe, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China - Page 4 of 33 - Report No.: ET-24040220E 1. Test Summary Test Item Section Antenna requirement FCC part 15.203/15.247 (c) AC Power Line Conducted Emission FCC part 15.207 Conducted Peak Output Power FCC part 15.247 (b)(3) 6dB Bandwidth FCC part 15.247 (a)(2) Power Spectral Density FCC part 15.247 (e) Band Edge FCC part 15.247(d) Spurious Emission FCC part 15.205/15.209 Remarks: 1. Pass: The EUT complies with the essential requirements in the standard. 2. Test according to ANSI C63.10:2013 Result Pass Pass Pass Pass Pass Pass Pass Test by / Carr kang Yvan Fan Yvan Fan Yvan Fan Yvan Fan Carr kang 3. Note: Compliance determination rules 1).The Compliance determination of test results does not take into account measurement uncertainty. Measurement results are determined based on regulatory limitations or requirements specified by the applicant/manufacturer. If measurement uncertainty is taken into account, the applicant/manufacturer will bear all possible risks of non-compliance. 2).The measurement uncertainty please refer to each test result in the "Measurement Uncertainty" Measurement Uncertainty Test Item Uncertainty Criterion Measurement Uncertainty Notes Occupied Channel Bandwidth ±5% ±0.55% (1) RF output power, conducted ±1.5dB ±0.99dB (1) Power Spectral Density, conducted ±3dB ±0.61dB (1) Unwanted Emissions, conducted ±3dB ±0.64dB (1) AC Power Line Conducted Emission ±6dB ± 2.64 dB (1) Radiated emissions Below 1GHz ±6dB ±4.32 dB (1) Radiated emissions Above 1GHz ±6dB ±4.56dB (1) Note (1): The measurement uncertainty is for coverage factor of k=2 and a level of confidence of 95%. Tel:(86-755) 85259392 Email:[email protected] Web: www.etrlab.cn No.103, No.10, Phase I, Zone 3, Xinxing Industrial Park, Xinhe, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China - Page 5 of 33 - Report No.: ET-24040220E 2. General Information 2.1 General Description of EUT Product Name: Selfie Stick Model No.: Test Model: Difference of model(s) Hardware version: H10,H10S,KT02,KT02S,H14,H14SH18,H18S,ES-A110,ES-A111,ESA130,ES-A131,ES-A180,ES-A181,ES-A210,ES-A211,ES-B180,ESB181,ES-B210,ES-B211,ES-A110S,ES-A111S,ES-A130S,ES-A131S, ES-A180S,ES-A181S,ES-A210S,ES-A211S,ES-B180S,ES-B181S,ESB210S,ES-B211S,ES-A110D,ES-A111D,ES-A130D,ES-A131D,ESA180D,ES-A181D,ES-A210D,ES-A211D,ES-B180D,ES-B181D,ESB210D,ES-B211D H10-C All the model are the same circuit and RF module, except the model names and colors N/A Software version: N/A Sample(s) Status Engineer sample Operation Frequency: 2402MHz~2480MHz Channel Numbers: 40 Channel separation: Modulation technology: 2MHz GFSK Battery: Antenna Type: Antenna gain: Power supply: DC 3.7V 200mAh PCB Antenna 0.31dBi(Declare by applicant) Note: Antenna information is provided by applicant, Testing lab is not responsible for the accuracy of the information. DC 3.7V from battery Tel:(86-755) 85259392 Email:[email protected] Web: www.etrlab.cn No.103, No.10, Phase I, Zone 3, Xinxing Industrial Park, Xinhe, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China - Page 6 of 33 - Report No.: ET-24040220E Operation Frequency each of channel Channel Frequency Channel Frequency Channel Frequency Channel Frequency 1 2402 MHz 11 2422 MHz 21 2442 MHz 31 2462 MHz 2 2404 MHz 12 2424 MHz 22 2444 MHz 32 2464 MHz 3 2406 MHz 13 2426 MHz 23 2446 MHz 33 2466 MHz 4 2408 MHz 14 2428 MHz 24 2448 MHz 34 2468 MHz 5 2410 MHz 15 2430 MHz 25 2450 MHz 35 2470 MHz 6 2412 MHz 16 2432 MHz 26 2452 MHz 36 2472 MHz 7 2414 MHz 17 2434 MHz 27 2454 MHz 37 2474 MHz 8 2416 MHz 18 2436 MHz 28 2456 MHz 38 2476 MHz 9 2418 MHz 19 2438 MHz 29 2458 MHz 39 2478 MHz 10 2420 MHz 20 2440 MHz 30 2460 MHz 40 2480 MHz Note: In section 15.31(m), regards to the operating frequency range over 10 MHz, the Lowest frequency, the middle frequency, and the highest frequency of channel were selected to perform the test, and the selected channel see below: Test channel Frequency (MHz) Lowest channel Middle channel Highest channel 2402MHz 2440MHz 2480MHz Tel:(86-755) 85259392 Email:[email protected] Web: www.etrlab.cn No.103, No.10, Phase I, Zone 3, Xinxing Industrial Park, Xinhe, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China - Page 7 of 33 - Report No.: ET-24040220E 2.2 Test mode Transmitting mode Keep the EUT in continuously transmitting mode EUT was test with maximum power control level. Remark: For battery operated equipment, the EUT was performed using a new DC 3.7V battery. 2.3 Description of Support Units No. Description 1 Adapter Manufacturer Xiao mi Model 5V/1A Serial Number / 2.4 Deviation from Standards None. 2.5 Abnormalities from Standard Conditions None. 2.6 Test Facility Test laboratory: Shenzhen ETR Standard Technology Co., Ltd. CNAS Registration Number: L11864 A2LA Certificate Number: 6640.01 FCC Designation Number: CN1326 FCC Test Firm Registration: 183064 2.7 Test Location All tests were performed at: Laboratory location: No.103, No.10, Phase I, Zone 3, Xinxing Industrial Park, Xinhe, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China Telephone: +86 755 85259392 Fax: +86 755 27219460 2.8 Additional Instructions Test Software WS8000 RF Test_V0.0.4_20220402.exe Power level setup Default Tel:(86-755) 85259392 Email:[email protected] Web: www.etrlab.cn No.103, No.10, Phase I, Zone 3, Xinxing Industrial Park, Xinhe, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China - Page 8 of 33 - Report No.: ET-24040220E 3. Test Instruments list Item Equipment name Manufacturer Model Serial No. 1 EMI Test Receiver Rohde&schwarz ESCI7 100605 2 EMI Test Receiver Rohde&schwarz ESCI3 102696 3 Loop Antenna schwarabeck FMZB 1519 B FMZB 1519 B 4 Broadband antenna schwarabeck VULB9168 1064 5 Horn antenna schwarabeck BBHA9120D 9120D-1145 6 amplifier EMtrace RP01A 50117 7 Artificial power network schwarabeck NSLK8127 8127483 8 Artificial power network ETS 3186/2NM 1132 9 10dB attenuator HUBER+SUHNE R 10dB / 10 amplifier Space-Dtronics EWLAN0118 G-P40 19113001 11 Filter Xingbo XBLBQGTA19 210410-3-1 12 Spectrum analyzer KEYSIGHT N9020A MY55370280 Calibration date 2024.3.012 2024.3.012 2024.3.19 2024.3.19 2024.3.19 2024.3.012 2024.3.012 2024.3.012 2024.3.012 2024.3.012 2024.3.012 2024.3.012 Due date 2025.3.11 2025.3.11 2026.3.18 2026.3.18 2026.3.18 2025.3.11 2025.3.11 2025.3.11 2025.3.11 2025.3.11 2025.3.11 2025.3.11 13 Power detector box MWRFtest MW100-PSB MW201020JYT 2024.3.012 2025.3.11 14 Power meter Rohde&Schwarz NRP-Z11 1138.3004.02117725-vh 2024.3.012 2025.3.11 Note: the calibration interval of the above test instruments is 12 or 24 months and the calibrations are traceable to international system unit (SI). Software Name RF test software Manufacturer MWRFtest Model MTS 8310 Version V2.0.0.0 Conducted test software EZ-EMC Farad Ver.EMC-CON 3A1.1 Radiated test software EZ-EMC Farad Ver.FA-03A2 RE Tel:(86-755) 85259392 Email:[email protected] Web: www.etrlab.cn No.103, No.10, Phase I, Zone 3, Xinxing Industrial Park, Xinhe, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China - Page 9 of 33 - Report No.: ET-24040220E 4. Test results and Measurement Data 4.1 Antenna requirement Standard requirement: FCC Part15 C Section 15.203 /247(c) 15.203 requirement: An intentional radiator shall be designed to ensure that no antenna other than that furnished by the responsible party shall be used with the device. The use of a permanently attached antenna or of an antenna that uses a unique coupling to the intentional radiator, the manufacturer may design the unit so that a broken antenna can be replaced by the user, but the use of a standard antenna jack or electrical connector is prohibited. 15.247(c) (1)(i) requirement: (i) Systems operating in the 2400-2483.5 MHz band that is used exclusively for fixed. Point-to-point operations may employ transmitting antennas with directional gain greater than 6dBi provided the maximum conducted output power of the intentional radiator is reduced by 1 dB for every 3 dB that the directional gain of the antenna exceeds 6dBi. EUT Antenna: The antenna is PCB antenna, the best case gain of the antenna is 0.31 dBi, reference to the appendix II for details. Tel:(86-755) 85259392 Email:[email protected] Web: www.etrlab.cn No.103, No.10, Phase I, Zone 3, Xinxing Industrial Park, Xinhe, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China - Page 10 of 33 Report No.: ET-24040220E - 4.2 Conducted Emissions Test Requirement: Test Method: Test Frequency Range: Receiver setup: Limit: Test setup: FCC Part15 C Section 15.207 ANSI C63.10:2013 150KHz to 30MHz RBW=9KHz, VBW=30KHz, Sweep time=auto Frequency range (MHz) Limit (dBuV) Quasi-peak Average 0.15-0.5 66 to 56* 56 to 46* 0.5-5 56 46 5-30 60 50 * Decreases with the logarithm of the frequency. Test procedure: 1. The E.U.T and simulators are connected to the main power through a line impedance stabilization network (L.I.S.N.). This provides a 50ohm/50uH coupling impedance for the measuring equipment. 2. The peripheral devices are also connected to the main power through a LISN that provides a 50ohm/50uH coupling impedance with 50ohm termination. (Please refer to the block diagram of the test setup and photographs). 3. Both sides of A.C. line are checked for maximum conducted interference. In order to find the maximum emission, the relative positions of equipment and all of the interface cables must be changed according to ANSI C63.10:2013 on conducted measurement. Test Instruments: Refer to section 3.0 for details Test mode: Refer to section 2.2 for details Test environment: Temp.: 25.9C Humid.: 56% Press.: 1012mbar Test voltage: AC 120V, 60Hz Test results: Pass Remark: 1. Both high voltage and low voltage have been tested, and the report only shows the worst case data with AC 120V/60Hz. 2. All mode have been tested, the report only shows the worst mode (2440MHz) data. Tel:(86-755) 85259392 Email:[email protected] Web: www.etrlab.cn No.103, No.10, Phase I, Zone 3, Xinxing Industrial Park, Xinhe, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China Measurement data Line: - Page 11 of 33 Report No.: ET-24040220E Tel:(86-755) 85259392 Email:[email protected] Web: www.etrlab.cn No.103, No.10, Phase I, Zone 3, Xinxing Industrial Park, Xinhe, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China Neutral: - Page 12 of 33 Report No.: ET-24040220E Notes: 1. An initial pre-scan was performed on the line and neutral lines with peak detector. 2. Quasi-Peak and Average measurement were performed at the frequencies with maximized peak emission. 3. Level =Receiver Read level + Factor (Factor= LISN Factor + Cable Loss+ Attenuator Factor) 4. If the average limit is met when using a quasi-peak detector receiver, the EUT shall be deemed to meet both limits and measurement with the average detector receiver is unnecessary. Tel:(86-755) 85259392 Email:[email protected] Web: www.etrlab.cn No.103, No.10, Phase I, Zone 3, Xinxing Industrial Park, Xinhe, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China - 4.3 Duty cycle Test Method : Limit: Test setup: - Page 13 of 33 ANSI C63.10:2013 / Report No.: ET-24040220E Test Instruments: Test mode: Test environment: Test voltage: Test results: Measurement Result Test channel Lowest Middle Highest Refer to section 3.0 for details Refer to section 2.2 for details Temp.: 24.9C DC 3.7V Pass Duty Cycle (%) 100 100 100 Humid.: 51%RH Tel:(86-755) 85259392 Email:[email protected] Web: www.etrlab.cn No.103, No.10, Phase I, Zone 3, Xinxing Industrial Park, Xinhe, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China Test plot as follows: - Page 14 of 33 Report No.: ET-24040220E Lowest channel Middle channel Highest channel Tel:(86-755) 85259392 Email:[email protected] Web: www.etrlab.cn No.103, No.10, Phase I, Zone 3, Xinxing Industrial Park, Xinhe, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China - Page 15 of 33 Report No.: ET-24040220E - 4.4 Conducted Output Power Test Requirement : Test Method : Limit: Test setup: FCC Part15 C Section 15.247 (b)(3) ANSI C63.10:2013 and KDB558074 D01 15.247 Meas Guidance v05r02 30dBm Test Instruments: Test mode: Test environment: Test voltage: Test results: Refer to section 3.0 for details Refer to section 2.2 for details Temp.: 24.9C DC 3.7V Pass Humid.: 51%RH Measurement Result Test channel Lowest Middle Highest Output Power (dBm) -1.15 -0.30 -0.48 Limit(dBm) 30.00 Result Pass Tel:(86-755) 85259392 Email:[email protected] Web: www.etrlab.cn No.103, No.10, Phase I, Zone 3, Xinxing Industrial Park, Xinhe, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China - 4.5 6dB Bandwidth Test Requirement : Test Method : Limit: Test setup: - Page 16 of 33 Report No.: ET-24040220E FCC Part15 C Section 15.247 (a)(2) ANSI C63.10:2013 and KDB558074 D01 15.247 Meas Guidance v05r02 >500KHz Test Instruments: Test mode: Test environment: Test voltage: Test results: Refer to section 3.0 for details Refer to section 2.2 for details Temp.: 24.9C DC 3.7V Pass Humid.: 51%RH Measurement Result Test channel Lowest Middle Highest 6dB Bandwidth (MHz) 0.7556 0.7621 0.7727 Limit(KHz) >500 Result Pass Tel:(86-755) 85259392 Email:[email protected] Web: www.etrlab.cn No.103, No.10, Phase I, Zone 3, Xinxing Industrial Park, Xinhe, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China Test plot as follows: - Page 17 of 33 Report No.: ET-24040220E Lowest channel Middle channel Highest channel Tel:(86-755) 85259392 Email:[email protected] Web: www.etrlab.cn No.103, No.10, Phase I, Zone 3, Xinxing Industrial Park, Xinhe, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China - Page 18 of 33 Report No.: ET-24040220E - 4.6 Power Spectral Density Test Requirement: Test Method: Limit: Test setup: FCC Part15 C Section 15.247 (e) ANSI C63.10:2013 and KDB558074 D01 15.247 Meas Guidance v05r02 8dBm/3kHz Test Instruments: Test mode: Test environment: Test voltage: Test results: Refer to section 3.0 for details Refer to section 2.2 for details Temp.: 24.9C DC 3.7V Pass Humid.: 51%RH Measurement Result Test channel Lowest Middle Highest Power Spectral Density (dBm/3kHz) -1.233 -0.384 -0.561 Limit(dBm/3kHz) 8.00 Result Pass Tel:(86-755) 85259392 Email:[email protected] Web: www.etrlab.cn No.103, No.10, Phase I, Zone 3, Xinxing Industrial Park, Xinhe, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China Test plot as follows: - Page 19 of 33 Report No.: ET-24040220E Lowest channel Middle channel Highest channel Tel:(86-755) 85259392 Email:[email protected] Web: www.etrlab.cn No.103, No.10, Phase I, Zone 3, Xinxing Industrial Park, Xinhe, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China - Page 20 of 33 Report No.: ET-24040220E - 4.7 Band edges Conducted Emission Method Test Requirement: Test Method: Limit: Test setup: FCC Part15 C Section 15.247 (d) KDB558074 D01 DTS Meas Guidance v05or02 In any 100 kHz bandwidth outside the frequency band in which the spread spectrum intentional radiator is operating, the radio frequency power that is produced by the intentional radiator shall be at least 20 dB below that in the 100 kHz bandwidth within the band that contains the highest level of the desired power, based on either an RF conducted or a radiated measurement. Test Instruments: Test mode: Test environment: Test voltage: Test results: Test plot as follows: Refer to section 3.0 for details Refer to section 2.2 for details Temp.: 24.9C DC 3.7V Pass Humid.: 51%RH Lowest channel Highest channel Tel:(86-755) 85259392 Email:[email protected] Web: www.etrlab.cn No.103, No.10, Phase I, Zone 3, Xinxing Industrial Park, Xinhe, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China - Page 21 of 33 Report No.: ET-24040220E - Radiated Emission Method Test Requirement: Test Method: Test Frequency Range: Test site: Receiver setup: Limit: Test setup: FCC Part15 C Section 15.209 and 15.205 ANSI C63.10: 2013 All of the restrict bands were tested, only the worst band's (2310MHz to 2500MHz) data was showed. Measurement Distance: 3m Frequency Detector RBW VBW Value Above 1GHz Peak Average 1MHz 1MHz 3MHz 3MHz Peak Average Frequency Limit (dBuV/m @3m) Value Above 1GHz 54.00 74.00 Average Peak Test Procedure: Test Instruments: Test mode: Test environment: Test voltage: Test results: 1. The EUT was placed on the top of a rotating table 1.5 meters above the ground at a 3 meter camber. The table was rotated 360 degrees to determine the position of the highest radiation. 2. The EUT was set 3 meters away from the interference-receiving antenna, which was mounted on the top of a variable-height antenna tower. 3. The antenna height is varied from one meter to four meters above the ground to determine the maximum value of the field strength. Both horizontal and vertical polarizations of the antenna are set to make the measurement. 4. For each suspected emission, the EUT was arranged to its worst case and then the antenna was tuned to heights from 1 meter to 4 meters and the rota table was turned from 0 degrees to 360 degrees to find the maximum reading. 5. The test-receiver system was set to Peak Detect Function and Specified Bandwidth with Maximum Hold Mode. 6. If the emission level of the EUT in peak mode was 10dB lower than the limit specified, then testing could be stopped and the peak values of the EUT would be reported. Otherwise the emissions that did not have 10dB margin would be re-tested one by one using peak, quasi-peak or average method as specified and then reported in a data sheet. 7. The radiation measurements are performed in X, Y, Z axis positioning. And found the Y axis positioning which it is worse case, only the test worst case mode is recorded in the report. Refer to section 3.0 for details Refer to section 2.2 for details Temp.: 24.9C Humid.: 51%RH DC 3.7V Pass Tel:(86-755) 85259392 Email:[email protected] Web: www.etrlab.cn No.103, No.10, Phase I, Zone 3, Xinxing Industrial Park, Xinhe, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China - Page 22 of 33 Report No.: ET-24040220E - Measurement Result: Test channel: Peak value: Frequency (MHz) Read Level (dBuV) 2310.00 62.62 2390.00 65.98 2310.00 62.09 2390.00 65.22 Average value: Frequency (MHz) Read Level (dBuV) 2310.00 51.88 2390.00 56.38 2310.00 52.89 2390.00 55.62 Antenna Factor (dB/m) 27.40 27.10 27.40 27.10 Antenna Factor (dB/m) 27.40 27.10 27.40 27.10 Cable Loss (dB) 3.43 3.43 3.43 3.43 Cable Loss (dB) 3.43 3.43 3.43 3.43 Lowest Preamp Factor (dB) 45.40 45.40 45.40 45.40 Level Limit Line (dBuV/m) (dBuV/m) 48.05 51.11 47.52 50.35 74.00 74.00 74.00 74.00 Over Limit (dB) -25.95 -22.89 -26.48 -23.65 Polarization Horizontal Horizontal Vertical Vertical Preamp Factor (dB) 45.40 45.40 45.40 45.40 Level Limit Line (dBuV/m) (dBuV/m) 37.31 41.51 38.32 40.75 54.00 54.00 54.00 54.00 Over Limit (dB) -16.69 -12.49 -15.68 -13.26 Polarization Horizontal Horizontal Vertical Vertical Test channel: Highest Peak value: Frequency (MHz) Read Level (dBuV) 2483.50 68.00 2500.00 61.89 2483.50 65.46 2500.00 62.02 Average value: Antenna Factor (dB/m) 27.80 27.80 27.80 27.80 Cable Loss (dB) 3.56 3.56 3.56 3.56 Preamp Factor (dB) 45.40 45.40 45.40 45.40 Level Limit Line (dBuV/m) (dBuV/m) 53.96 47.85 51.42 47.98 74.00 74.00 74.00 74.00 Over Limit (dB) -20.04 -26.15 -22.58 -26.02 Polarization Horizontal Horizontal Vertical Vertical Frequency (MHz) Read Level (dBuV) Antenna Factor (dB/m) Cable Loss (dB) Preamp Factor (dB) Level Limit Line (dBuV/m) (dBuV/m) Over Limit (dB) Polarization 2483.50 55.56 27.80 3.56 45.40 41.52 54.00 -12.48 Horizontal 2500.00 52.75 27.80 3.56 45.40 38.71 54.00 -15.29 Horizontal 2483.50 54.15 27.80 3.56 45.40 40.11 54.00 -13.90 Vertical 2500.00 51.85 27.80 3.56 45.40 37.81 54.00 -16.19 Vertical Remarks: 1. Level = Read level + Antenna Factor + Cable Loss Preamplifier Factor 2. Emissions more than 20 dB below the limit do not need to be reported. 3. The pre-test were performed on lowest, middle and highest frequencies, only the worst case's (lowest and highest frequencies) data was showed. Tel:(86-755) 85259392 Email:[email protected] Web: www.etrlab.cn No.103, No.10, Phase I, Zone 3, Xinxing Industrial Park, Xinhe, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China - Page 23 of 33 Report No.: ET-24040220E - 4.8 Spurious Emission Conducted Emission Method Test Requirement: FCC Part15 C Section 15.247 (d) Test Method: KDB558074 D01 DTS Meas Guidance v05or02 Limit: In any 100 kHz bandwidth outside the frequency band in which the spread spectrum intentional radiator is operating, the radio frequency power that is produced by the intentional radiator shall be at least 20 dB below that in the 100 kHz bandwidth within the band that contains the highest level of the desired power, based on either an RF conducted or a radiated measurement. Test setup: Test Instruments: Test mode: Test environment: Test voltage: Test results: Refer to section 3.0 for details Refer to section 2.2 for details Temp.: 24.9C DC 3.7V Pass Humid.: 51%RH Tel:(86-755) 85259392 Email:[email protected] Web: www.etrlab.cn No.103, No.10, Phase I, Zone 3, Xinxing Industrial Park, Xinhe, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China - Test plot as follows: Lowest channel - Page 24 of 33 Report No.: ET-24040220E Middle channel 30MHz~26.5GHz Highest channel 30MHz~26.5GHz 30MHz~26.5GHz Tel:(86-755) 85259392 Email:[email protected] Web: www.etrlab.cn No.103, No.10, Phase I, Zone 3, Xinxing Industrial Park, Xinhe, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China - Page 25 of 33 Report No.: ET-24040220E - Radiated Emission Method Test Requirement: Test Method: Test Frequency Range: Test site: Receiver setup: Limit: Test setup: FCC Part15 C Section 15.209 ANSI C63.10: 2013 9kHz to 25GHz Measurement Distance: 3m Frequency Detector RBW VBW Value 9KHz-150KHz Quasi-peak 200Hz 600Hz Quasi-peak 150KHz-30MHz Quasi-peak 9KHz 30KHz Quasi-peak 30MHz-1GHz Quasi-peak 120KHz 300KHz Quasi-peak Above 1GHz Peak Peak 1MHz 1MHz 3MHz 10Hz Peak Average Frequency Limit (uV/m) Value Measurement Distance 0.009MHz-0.490MHz 2400/F(KHz) QP 300m 0.490MHz-1.705MHz 24000/F(KHz) QP 300m 1.705MHz-30MHz 30 QP 30m 30MHz-88MHz 100 QP 88MHz-216MHz 150 QP 216MHz-960MHz 200 QP 3m 960MHz-1GHz 500 QP Above 1GHz 500 5000 Average Peak For radiated emissions from 9kHz to 30MHz For radiated emissions from 30MHz to1GHz For radiated emissions above 1GHz Tel:(86-755) 85259392 Email:[email protected] Web: www.etrlab.cn No.103, No.10, Phase I, Zone 3, Xinxing Industrial Park, Xinhe, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China - Page 26 of 33 Report No.: ET-24040220E - Test Procedure: 1. The EUT was placed on the top of a rotating table (0.8m for below 1G and 1.5m for above 1G) above the ground at a 3 meter camber. The table was rotated 360 degrees to determine the position of the highest radiation. 2. The EUT was set 3 meters away from the interference-receiving antenna, which was mounted on the top of a variable-height antenna tower. 3. The antenna height is varied from one meter to four meters above the ground to determine the maximum value of the field strength. Both horizontal and vertical polarizations of the antenna are set to make the measurement. 4. For each suspected emission, the EUT was arranged to its worst case and then the antenna was tuned to heights from 1 meter to 4 meters and the rota table was turned from 0 degrees to 360 degrees to find the maximum reading. 5. The test-receiver system was set to Peak Detect Function and Specified Bandwidth with Maximum Hold Mode. 6. If the emission level of the EUT in peak mode was 10dB lower than the limit specified, then testing could be stopped and the peak values of the EUT would be reported. Otherwise the emissions that did not have 10dB margin would be re-tested one by one using peak, quasi-peak or average method as specified and then reported in a data sheet. Test Instruments: Refer to section 3.0 for details Test mode: Refer to section 2.2 for details Test voltage: DC 3.7V Test environment: Temp.: 24.9C Humid.: 51% Press.: 1012mbar Test results: Pass Remarks: 1. The report only shows the worst mode. 2. Pre-scan all kind of the place mode (X-axis, Y-axis, Z-axis), and found the Y-axis which it is worse case. Tel:(86-755) 85259392 Email:[email protected] Web: www.etrlab.cn No.103, No.10, Phase I, Zone 3, Xinxing Industrial Park, Xinhe, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China - Page 27 of 33 Report No.: ET-24040220E - Measurement Result: 9kHz~30MHz The emission from 9 kHz to 30MHz was pre-tested and found the result was 20dB lower than the limit, and according to 15.31(o) & RSS-Gen 6.13, the test result no need to reported. Tel:(86-755) 85259392 Email:[email protected] Web: www.etrlab.cn No.103, No.10, Phase I, Zone 3, Xinxing Industrial Park, Xinhe, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China - Page 28 of 33 Report No.: ET-24040220E - Below 1GHz All mode has been tested, the report only shows the worst mode (2440MHz) data. Vertical: Tel:(86-755) 85259392 Email:[email protected] Web: www.etrlab.cn No.103, No.10, Phase I, Zone 3, Xinxing Industrial Park, Xinhe, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China Horizontal: - Page 29 of 33 Report No.: ET-24040220E Remarks: Level =Receiver Reading + Factor Factor= Antenna Factor + Cable Factor Preamplifier Factor Tel:(86-755) 85259392 Email:[email protected] Web: www.etrlab.cn No.103, No.10, Phase I, Zone 3, Xinxing Industrial Park, Xinhe, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China - Page 30 of 33 Report No.: ET-24040220E - Above 1GHz Test channel: Peak value: Frequency (MHz) Read Level (dBuV) 4804.00 55.82 Antenna Factor (dB/m) 32.10 Lowest Cable Loss (dB) 5.96 Preamp Factor (dB) 45.70 Level (dBuV/m) 48.18 7206.00 53.44 36.10 6.86 45.50 50.90 9608.00 51.40 38.30 8.25 46.20 51.75 12010.00 * -- -- -- -- 14412.00 * -- -- -- -- 4804.00 54.23 32.10 5.96 45.70 46.59 7206.00 53.04 36.10 6.86 45.50 50.50 9608.00 50.04 38.30 8.25 46.20 50.39 12010.00 * -- -- -- -- 14412.00 * Average value: Frequency (MHz) Read Level (dBuV) -- Antenna Factor (dB/m) -- -- -- Cable Loss (dB) Preamp Factor (dB) Level (dBuV/m) 4804.00 44.64 32.10 5.96 45.70 37.00 7206.00 41.00 36.10 6.86 45.50 38.46 9608.00 39.74 38.30 8.25 46.20 40.09 12010.00 * -- -- -- -- 14412.00 * -- -- -- -- 4804.00 45.00 32.10 5.96 45.70 37.36 7206.00 43.06 36.10 6.86 45.50 40.52 9608.00 38.99 38.30 8.25 46.20 39.34 12010.00 * -- -- -- -- 14412.00 * -- -- -- -- Remarks: 1. Level = Read level + Antenna Factor + Cable Loss Preamplifier Factor 2. "*", means this data is the too weak instrument of signal is unable to test. 3. Emissions more than 20 dB below the limit do not need to be reported. Limit Line (dBuV/m) 74.00 74.00 74.00 74.00 74.00 74.00 74.00 74.00 74.00 74.00 Limit Line (dBuV/m) 54.00 54.00 54.00 54.00 54.00 54.00 54.00 54.00 54.00 54.00 Over Limit (dB) -25.82 -23.10 -22.25 ---27.41 -23.50 -23.61 --- polarization Vertical Vertical Vertical Vertical Vertical Horizontal Horizontal Horizontal Horizontal Horizontal Over Limit (dB) -17.00 -15.54 -13.91 ---16.64 -13.48 -14.66 --- polarization Vertical Vertical Vertical Vertical Vertical Horizontal Horizontal Horizontal Horizontal Horizontal Tel:(86-755) 85259392 Email:[email protected] Web: www.etrlab.cn No.103, No.10, Phase I, Zone 3, Xinxing Industrial Park, Xinhe, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China - Page 31 of 33 Report No.: ET-24040220E - Test channel: Peak value: Frequency (MHz) Read Level (dBuV) 4880.00 54.81 Antenna Factor (dB/m) 32.10 Middle Cable Loss (dB) 5.96 Preamp Factor (dB) 45.70 Level (dBuV/m) 47.17 Limit Line (dBuV/m) 74.00 7320.00 53.15 36.80 6.86 45.50 51.31 74.00 9760.00 51.15 38.40 8.25 46.20 51.60 74.00 12200.00 * -- -- -- -- 74.00 14640.00 * -- -- -- -- 74.00 4880.00 55.07 32.10 5.96 45.70 47.43 74.00 7320.00 53.48 36.80 6.86 45.50 51.64 74.00 9760.00 49.94 38.40 8.25 46.20 50.39 74.00 12200.00 * -- -- -- -- 74.00 14640.00 * Average value: Frequency (MHz) Read Level (dBuV) 4880.00 45.07 -- Antenna Factor (dB/m) 32.10 -- -- -- 74.00 Cable Loss (dB) 5.96 Preamp Factor (dB) 45.70 Level (dBuV/m) 37.43 Limit Line (dBuV/m) 54.00 7320.00 40.25 36.80 6.86 45.50 38.41 54.00 9760.00 38.70 38.40 8.25 46.20 39.15 54.00 12200.00 * -- -- -- -- 54.00 14640.00 * -- -- -- -- 54.00 4880.00 44.92 32.10 5.96 45.70 37.28 54.00 7320.00 42.68 36.80 6.86 45.50 40.84 54.00 9760.00 39.71 38.40 8.25 46.20 40.16 54.00 12200.00 * -- -- -- -- 54.00 14640.00 * -- -- -- -- 54.00 Remarks: 1. Final Level =Receiver Read level + Antenna Factor + Cable Loss Preamplifier Factor 2. "*", means this data is the too weak instrument of signal is unable to test. 3. Emissions more than 20 dB below the limit do not need to be reported. Over Limit (dB) -26.83 -22.69 -22.40 ---26.57 -22.36 -23.61 --- polarization Vertical Vertical Vertical Vertical Vertical Horizontal Horizontal Horizontal Horizontal Horizontal Over Limit (dB) -16.57 -15.59 -14.85 ---16.72 -13.16 -13.84 --- polarization Vertical Vertical Vertical Vertical Vertical Horizontal Horizontal Horizontal Horizontal Horizontal Tel:(86-755) 85259392 Email:[email protected] Web: www.etrlab.cn No.103, No.10, Phase I, Zone 3, Xinxing Industrial Park, Xinhe, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China - Page 32 of 33 Report No.: ET-24040220E - Test channel: Peak value: Frequency (MHz) Read Level (dBuV) 4960.00 54.11 Antenna Factor (dB/m) 32.70 Highest Cable Loss (dB) 5.96 Preamp Factor (dB) 45.70 Level (dBuV/m) 47.07 7440.00 52.62 36.40 6.86 45.50 50.38 9920.00 50.75 38.00 8.25 46.20 50.80 12400.00 * -- -- -- -- 14880.00 * -- -- -- -- 4960.00 53.56 32.70 5.96 45.70 46.52 7440.00 51.91 36.40 6.86 45.50 49.67 9920.00 50.17 38.00 8.25 46.20 50.22 12400.00 * -- -- -- -- 14880.00 * Average value: Frequency (MHz) Read Level (dBuV) 4960.00 43.77 -- Antenna Factor (dB/m) 32.70 -- -- -- Cable Loss (dB) 5.96 Preamp Factor (dB) 45.70 Level (dBuV/m) 36.73 7440.00 40.14 36.40 6.86 45.50 37.90 9920.00 39.15 38.00 8.25 46.20 39.20 12400.00 * -- -- -- -- 14880.00 * -- -- -- -- 4960.00 43.08 32.70 5.96 45.70 36.04 7440.00 40.05 36.40 6.86 45.50 37.81 9920.00 38.01 38.00 8.25 46.20 38.06 12400.00 * -- -- -- -- 14880.00 * -- -- -- -- Remarks: 1. Level = Read level + Antenna Factor + Cable Loss Preamplifier Factor 2. "*", means this data is the too weak instrument of signal is unable to test. 3. Emissions more than 20 dB below the limit do not need to be reported. Limit Line (dBuV/m) 74.00 74.00 74.00 74.00 74.00 74.00 74.00 74.00 74.00 74.00 Limit Line (dBuV/m) 54.00 54.00 54.00 54.00 54.00 54.00 54.00 54.00 54.00 54.00 Over Limit (dB) -26.93 -23.62 -23.20 ---27.48 -24.33 -23.78 --- polarization Vertical Vertical Vertical Vertical Vertical Horizontal Horizontal Horizontal Horizontal Horizontal Over Limit (dB) -17.27 -16.10 -14.80 ---17.96 -16.19 -15.94 --- polarization Vertical Vertical Vertical Vertical Vertical Horizontal Horizontal Horizontal Horizontal Horizontal Tel:(86-755) 85259392 Email:[email protected] Web: www.etrlab.cn No.103, No.10, Phase I, Zone 3, Xinxing Industrial Park, Xinhe, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China - Page 33 of 33 - 5. Test Setup Photo Reference to the appendix I for details. 6. EUT Constructional Details Reference to the appendix II for details. ------End------ Report No.: ET-24040220E Tel:(86-755) 85259392 Email:[email protected] Web: www.etrlab.cn No.103, No.10, Phase I, Zone 3, Xinxing Industrial Park, Xinhe, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China
Related FCC IDs:
- 2BF3X-H10-C - Dongguan Mingqin Xin Electronics Co., Ltd. Selfie Stick [-H10-C] Microsoft Word 2016 Microsoft Word 2016