Lula You Intertek
RF Exposure
Shenzhen Huntkey Electric Co., Ltd SCA109 2AVYR-SCA109 2AVYRSCA109 sca109
Not Your Device? Search For Manuals or Datasheets below:
File Info : application/pdf, 9 Pages, 328.60KB
Document DEVICE REPORTGetApplicationAttachment.html?id=6578788Shenzhen Huntkey Electric Co., Ltd TEST REPORT SCOPE OF WORK EMC TESTINGSCA109 REPORT NUMBER 210506172GZU-002 ISSUE DATE [REVISED DATE] 22-May-2022 [---------------------] PAGES 9 DOCUMENT CONTROL NUMBER © 2017 INTERTEK TEST REPORT Room 02, & 101/E201/E301/ E401/E501/E601/E701/E801 of Room 01 1-8/F., No. 7-2. Caipin Road, Science City, GETDD, Guangzhou, Guangdong, China Telephone: +86 20 8213 9688 Facsimile: +86 20 3205 7538 www.intertek.com.cn Applicant Name & Address Manufacturing Site Intertek Report No: FCC ID: : Shenzhen Huntkey Electric Co., Ltd Huntkey Industrial Park,XueXiang Village,Bantian Street,LONGGANG DISTRICT,518129,ShenZhen,Guangdong,China : 1:Shenzhen Huntkey Electronics Co., Ltd Huntkey Industrial Park,XueXiang Village,Bantian Street,LONGGANG DISTRICT,518129,ShenZhen,Guangdong,China 2:HEYUAN HUNTKEY INDUSTRIAL CO., LTD. Block D, Huntkey Industrial Park No.18, Longling Industrial Area Yuancheng District Heyuan Guangdong 517000 China 210506172GZU-002 2AVYR-SCA109 Test standards 47 CFR PART 1, Subpart I, Section 1.1310 KDB 680106 D01 RF Exposure Wireless Charging App v03r01 Sample Description Product : Wireless charger Model No. : SCA109 Electrical Rating : Input: 125V, 60Hz, 0.8A Output: USB port: DC 5V/2.4A Wireless charge: up to 10W Serial No. Not Labeled Date Received : 06 May 2021 Date Test : 15 January 2022-20 January 2022 Conducted Prepared and Checked By Approved By: Richard Liu Engineer Dean Liu Project Engineer This report is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this report. Only the Client is authorized to permit copying or distribution of this report and then only in its entirety. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test results in this report are relevant only to the sample tested. This report by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program. Intertek Testing Services Shenzhen Ltd. Guangzhou Branch Room 02, & 101/E201/E301/E401/E501/E601/E701/E801 of Room 01 1-8/F., No. 7-2. Caipin Road, Science City, GETDD, Guangzhou, Guangdong, China Version: 21 August 2017 Page 2 of 9 TEST REPORT Intertek Report: No: 210506172GZU-002 CONTENT TESTREPORT........................................................................................................................... 1 CONTENT ............................................................................................................................. 3 1.0 TEST RESULT SUMMARY ............................................................................................ 4 2.0 GENERAL DESCRIPTION.............................................................................................. 5 2.1 PRODUCT DESCRIPTION ........................................................................................................5 2.2 TEST FACILITY......................................................................................................................5 2.3 EUT EXERCISING SOFTWARE..................................................................................................5 2.4 SPECIAL ACCESSORIES...........................................................................................................5 2.5 EQUIPMENT MODIFICATION ..................................................................................................5 2.6 SUPPORT EQUIPMENT LIST AND DESCRIPTION ..........................................................................6 3.0 EMF TEST.................................................................................................................. 7 3.1 STANDARD REQUIREMENT..........................................................................................................7 3.2 TEST DATA...............................................................................................................................8 4.0 TEST EQUIPMENT LIST ............................................................................................... 9 Version: 21 August 2017 Page 3 of 9 FCC Part 15.225-a Intertek Report: No: 210506172GZU-002 TEST REPORT 1.0 TEST RESULT SUMMARY Classification of EUT: Class B Test Item EMF Standard 47 CFR PART 1, Subpart I, Section 1.1310 Result PASS Remark: When determining the test results, measurement uncertainty of tests has been considered. The worst case's test data is input 9V/2A, which is presented in this test report. Version: 21 August 2017 Page 4 of 9 FCC Part 15.225-a TEST REPORT 2.0 General Description 2.1 Product Description Operating Frequency Type of Modulation: Antenna Type Power Supply: Power cord: 112.8kHz-146.1kHz MSK Inductive loop coil antenna Input: 125V, 60Hz, 0.8A Output: USB port: DC 5V/2.4A Wireless charge:up to 10W 1m x 2 wires unscreened cable Intertek Report: No: 210506172GZU-002 2.2 Test Facility Room102/104, No 203, KeZhu Road, Science City, GETDD Guangzhou, China A2LA Certificate Number 0078.10 Intertek Testing Services Shenzhen Ltd. Guangzhou Branch is accredited by A2LA and Listed in FCC website. FCC accredited test labs may perform both Certification testing under Parts 15 and 18 and Declaration of Conformity testing. 2.3 EUT Exercising Software N/A 2.4 Special Accessories N/A 2.5 Equipment Modification Any modifications installed previous to testing by Shenzhen Huntkey Electric Co., Ltd will be incorporated in each production model sold / leased in the United States. No modifications were installed by Intertek Testing Services Shenzhen Ltd. Guangzhou Branch. Version: 21 August 2017 Page 5 of 9 FCC Part 15.225-a TEST REPORT Intertek Report: No: 210506172GZU-002 2.6 Support Equipment List and Description This product was tested with corresponding support equipment as below: Support Equipment: Equipment WPT client Model No. Tx-test2 1st Cement resistance -- 2nd Cement resistance -- Cable: Description Model No. 1st Electric wire -- 2nd Electric wire -- Rating DC 12V/0.83A,DC 7.5V/1.06A,DC 5V/1A 2 2 Supplier Shenzhen Huntkey Electric Co., Ltd Intertek Intertek Cable length/type 0.8 m(unshielded) 0.8 m(unshielded) Supplied by Intertek Intertek Remark: the WPT client was one of typical client devices, it's selected such that the EUT was fully exercised at maximum power from its transmitter. It will not be sold together. To investigate the maximum EMI emission characteristics generates from EUT, the test system was pre-scanning tested based on the consideration of following EUT operation mode or test configuration mode which possible have effect on EMI emission level. Each of these EUT operation mode(s) or test configuration mode(s) mentioned above evaluated respectively Pretest mode Standby Mode Charging Mode Description kept transmitting continuously CH: Low WPT client is full load power mode,half CH: Middle full load power mode and saturated CH: High charging mode respectively, keep transmitting continuously. Version: 21 August 2017 Page 6 of 9 FCC Part 15.225-a Intertek Report: No: 210506172GZU-002 TEST REPORT 3.0 EMF TEST 3.1 Standard Requirement Systems operating under the provisions of this section shall be operated in a manner that ensures that the public is not exposed to radio frequency energy level in excess limit for maximum permissible exposure. In accordance with 47 CFR FCC Part 2 Subpart J, section 2.1091 this device has been defined as a mobile device whereby a distance of 0.1m normally can be maintained between the user and the device. (a) Limits for Occupational / Controlled Exposure Frequency Range (MHz) Electric Field Magnetic Field Strength (E) (V/m) Strength (H) (A/m) 0.3-3.0 3.0-30 30-300 300-1500 1500-100000 614 1842/f 61.4 --- 1.63 4.89/f 0.163 --- Power Density (S)(mW/cm2) (100)* (900/f)* 1.0 F/300 5 Averaging Times E 2 ,H 2or S (minutes) 6 6 6 6 6 (b) Limits for General Population / Uncontrolled Exposure Frequency Range (MHz) Electric Field Magnetic Field Strength (E) (V/m) Strength (H) (A/m) Power Density (S)(mW/cm2) 0.3-1.34 614 1.63 1.34-30 824/f 2.19/f 30-300 27.5 0.073 300-1500 -- -- 1500-100000 -- -- Note: f=frequency in MHz; *Plane-wave equivalent power density (100)* (180/f)* 0.2 F/1500 1.0 Averaging Times E 2 ,H 2or S (minutes) 30 30 30 30 30 Version: 21 August 2017 Page 7 of 9 FCC Part 15.225-a Intertek Report: No: 210506172GZU-002 TEST REPORT 3.2 Test Data Input Voltage: 125V/60Hz Ambient Condition: 24, 50%RH Test distance: 15 cm surrounding the device, and 20 cm away from the surface from the coil. H-Filed Strength: Test Probe Measure Result (A/m) Position Full load Half full load Saturated power mode power mode charging mode Side 1 0.041 0.039 0.037 Side 2 0.040 0.037 0.036 Side 3 0.042 0.036 0.035 Side 4 0.041 0.036 0.032 Top 0.046 0.040 0.040 50% Limit Limit (A/m) (A/m) 0.815 1.63 0.815 1.63 0.815 1.63 0.815 1.63 0.815 1.63 Version: 21 August 2017 Page 8 of 9 FCC Part 15.225-a Intertek Report: No: 210506172GZU-002 TEST REPORT 4.0 Test Equipment List Equip. No. Equipment EM007-03 Exposure Level Tester Model Manufacturer Cal. date ELT-400 NARDA 28/02/2021 Due date 27/02/2022 ********************************End of the test report****************************** Version: 21 August 2017 Page 9 of 9 FCC Part 15.225-a
Related FCC IDs:
- 2AVYR-SCA109 - Shenzhen Huntkey Electric Co., Ltd Wireless charger [-SCA109] Microsoft Word for Microsoft 365