FCC MPE Report

()

glyhe

RF Exposure Report

INNOVATIVE TECHNOLOGY ELECTRONICS LLC VTA245B Music Center with Bluetooth 2AFHW-VTA245B 2AFHWVTA245B vta245b

PDF Viewing Options

Not Your Device? Search For Manuals or Datasheets below:


File Info : application/pdf, 6 Pages, 183.66KB

Document DEVICE REPORTGetApplicationAttachment.html?id=4110844
Test Report No.: FM180712N003

RF EXPOSURE REPORT

Applicant Address

Innovative Technology Electronics, LLC 1 Channel Drive, Port Washington, NY 11050, USA

Manufacturer or Supplier
Address

Guangdong Leetac Electronics Technology Co ., Ltd. No.15 Danli Road, South District, Zhongshan, Guangdong, China.

Product

Music Center with Bluetooth

Brand Name

Victrola, Innovative Technology

Model

VTA-245B

Additional Model & ITVS-245B, VTA-245XXXX, ITVS-245XXXX(where X can be 0-9, A-Z or blank and Model Difference means color code of unit)

Date of tests

Jul. 12, 2018 ~ Aug. 27, 2018

FCC Part 2 (Section 2.1091) KDB 447498 D01 IEEE C95.1

CONCLUSION: The submitted sample was found to COMPLY with the test requirement

Tested by Tom Chen Project Engineer / EMC Department

Approved by Glyn He Supervisor/ EMC Department

Date: Dec. 03, 2018
This report is governed by, and incorporates by reference, CPS Conditions of Service as posted at the date of issuance of this report at http://www.bureauveritas.com/home/about-us/our-business/cps/about-us/terms-conditions/and is intended for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is permitted only with our prior written permission. This report sets forth our findings solely with respect to the test samples identified herein. The results set forth in this report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or any similar or identical product unless specifically and expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the information that you provided to us. Measurement uncertainty is only provided upon request for accredited tests. You have 60 days from date of issuance of this report to notify us of any material error or omission caused by our negligence or if you require measurement uncertainty; provided, however, that such notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time shall constitute you unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report contents.

Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch

No. 34, Chenwulu Section, Guantai Rd., Houjie Town, Dongguan City, Guangdong 523942, China
Page 1 of 6

Tel: +86 769 8593 5656 Fax: +86 769 8593 1080 Email: [email protected]
Report Version 1

Test Report No.: FM180712N003
TABLE OF CONTENTS
RELEASE CONTROL RECORD ................................................................................ 3 1. CERTIFICATION.............................................................................................. 4 2. RF EXPOSURE LIMIT .....................................................................................5 3. MPE CALCULATION FORMULA.....................................................................5 4. CLASSIFICATION ...........................................................................................5 5. ANTENNA GAIN ..............................................................................................6 6. CALCULATION RESULT OF MAXIMUM CONDUCTED POWER...................6

Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch

No. 34, Chenwulu Section, Guantai Rd., Houjie Town, Dongguan City, Guangdong 523942, China
Page 2 of 6

Tel: +86 769 8593 5656 Fax: +86 769 8593 1080 Email: [email protected]
Report Version 1

Test Report No.: FM180712N003

RELEASE CONTROL RECORD

ISSUE NO. FM180712N003

REASON FOR CHANGE Original release

DATE ISSUED Dec. 03, 2018

Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch

No. 34, Chenwulu Section, Guantai Rd., Houjie Town, Dongguan City, Guangdong 523942, China
Page 3 of 6

Tel: +86 769 8593 5656 Fax: +86 769 8593 1080 Email: [email protected]
Report Version 1

Test Report No.: FM180712N003
1. CERTIFICATION

FCC ID: PRODUCT: BRAND NAME: MODEL NO.: ADDITIONAL NO.:
APPLICANT:

2AFHW-VTA245B Music Center with Bluetooth Victrola, Innovative Technology VTA-245B ITVS-245B, VTA-245XXXX, ITVS-245XXXX(where X can be 0-9, A-Z or blank and means color code of unit) Innovative Technology Electronics, LLC

STANDARDS: FCC Part 2 (Section 2.1091)

KDB 447498 D01

IEEE C95.1

NOTE:
1. Additional models (see about table) are identical with the test model VTA-245B except the model number and trade name for marketing purpose. Remark: Victrola can be used for VTA-245B, VTA-245XXXX; Innovative Technology can be used for ITVS-245B, ITVS-245XXXX.

Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch

No. 34, Chenwulu Section, Guantai Rd., Houjie Town, Dongguan City, Guangdong 523942, China
Page 4 of 6

Tel: +86 769 8593 5656 Fax: +86 769 8593 1080 Email: [email protected]
Report Version 1

Test Report No.: FM180712N003

2. RF EXPOSURE LIMIT

LIMITS FOR MAXIMUM PERMISSIBLE EXPOSURE (MPE)

FREQUENCY ELECTRIC FIELD MAGNETIC FIELD POWER DENSITY AVERAGE TIME

RANGE (MHz) STRENGTH (V/m) STRENGTH (A/m)

(mW/cm2)

(minutes)

LIMITS FOR GENERAL POPULATION / UNCONTROLLED EXPOSURE

300-1500

...

...

F/1500

30

1500-100,000

...

...

1.0

30

F = Frequency in MHz

3. MPE CALCULATION FORMULA
Pd = (Pout*G) / (4*pi*r2) where Pd = power density in mW/cm2 Pout = output power to antenna in mW G = gain of antenna in linear scale Pi = 3.1416 R = distance between observation point and center of the radiator in cm

4. CLASSIFICATION
The antenna of this product, under normal use condition, is at least 20cm away from the body of the user. So, this device is classified as Mobile Device.

Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch

No. 34, Chenwulu Section, Guantai Rd., Houjie Town, Dongguan City, Guangdong 523942, China
Page 5 of 6

Tel: +86 769 8593 5656 Fax: +86 769 8593 1080 Email: [email protected]
Report Version 1

Test Report No.: FM180712N003

5. ANTENNA GAIN

The antennas provided to the EUT, please refer to the following table:

Transmitter Circuit

Peak Gain (dBi)

Antenna Type

Chain 0

0

PCB Antenna

6. CALCULATION RESULT OF MAXIMUM CONDUCTED AV POWER

The tuned conducted Average Power (declared by client)

Mode

Frequency (MHz)

Target Power (dBm)

Tolerance (dBm)

GFSK

2402-2480

-3

+-3

8DPSK

2402-2480

-7

+-3

Lower Tolerance
(dBm)
-6 -10

Upper Tolerance
(dBm)
0 -4

The measured conducted Average Power

Mode

Frequency (MHz)

GFSK 8DPSK

2402 2402

Averaged Power (dBm)
-1.31 -4.99

FREQUENCY BAND (MHz)
2402-2480

MAX AVERAGE POWER (dBm)
0

ANTENNA GAIN (dBi)
0

DISTANCE (cm)
20

POWER DENSITY (mW/cm2)
0.000199

LIMIT (mW/cm2)
1.0

--- END ---

Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch

No. 34, Chenwulu Section, Guantai Rd., Houjie Town, Dongguan City, Guangdong 523942, China
Page 6 of 6

Tel: +86 769 8593 5656 Fax: +86 769 8593 1080 Email: [email protected]
Report Version 1

