Jackson Dishwasher TempStar Spec Sheet

Jackson, Tempstar, Jackson Tempstar, Jackson Spec Sheet, Tempstar Spec Sheet, commercial dishwasher

Central Restaurant Products

https://assets.centralrestaurant.com/pdfs/specsheets/670-039

Jackson Dishwasher Parts Manual

Spec Sheet

Jackson TempStar - VL - Ventless Door Type Dishwasher, 230V, 1 Phase

PDF Viewing Options

Not Your Device? Search For Manuals or Datasheets below:


File Info : application/pdf, 2 Pages, 397.33KB

Document DEVICE REPORT670-039
TempStar®


TempStar®
Models
TempStar®
Specifications
Uses 0.89 gallons (3 liters) of water per rack Total automatic (normal) cycle - 57 seconds 58 racks per hour (normal) cycle 3/4 hp wash pump motor Single point connections for all utilities

Project Item Quantity CSI Section 11400 Approval Date

Standard Features

Mandatory Specs

· Sani-Sure TM feature assures proper Specify:

rinse water temperature

Electric

· Multi-cycle timer (Extra Heavy, Heavy, Medium, Normal)

Steam


· Specially designed stainless steel Specify voltage ______________


nozzles provide superior cleaning Specify booster size __________


action

· 17-1/4" (438 mm) door opening accepts 18" (457 mm) trays

Options

· Interchangeable wash/rinse arms screw out for simple cleanup
· Auto-fill/auto-start
· Door switch
· Delime/manual wash switch
· Vent fan control - shuts vent fan off when machine is idle
· Low watt density electric wash tank heater

Optional 40° F (22.2° C) rise booster heater is available at no additional cost (must be specified)
480V Electrical
Single Phase
1/2" Pressure Regulator
Drain Quench System
Scaltrol

· Hi-limit thermostat and low water protection
· Top mounted controls for ease of operation
· Adjustable bullet feet
· Uses standard 20" X 20" (508 mm X 508 mm) racks

Water Hammer Arrestor Flanged Feet False Panel Door Interlock Steam Booster Heater Security Package

· Front dress panel
· Detergent/rinse additive signal connection fuse box

Accessories
36-Compartment Rack

· Self-draining stainless steel pump

4-1/8" tall (105 mm)

· Built-in 70° F (38.9° C) rise booster heater is standard; 40° F (22.2° C) rise booster heater is available but must be specified at time of order

5-5/8" tall (143 mm) 7" tall (178 mm) Combination Rack

· Large scrap basket

Peg Rack

Field convertible from straight through to corner and vice versa
Field convertible from 3-phase to singlephase and vice versa
Heavy duty stainless steel construction

www.jacksonwws.com

TempStar®


C
 76 [1933mm]


17 [432mm]


1 2

B
 [14mm]


17 [434mm]


5734 [1468mm]

3 [79mm] C

1 [28mm]
 B


4 [104mm]


60 [1527mm]
 6241 [1584mm]

B
2541 [641mm]
2541 [641mm] 32 [813mm]

34 [866mm]

A

421 [114mm]

1341 [335mm]
 A


434 [120mm]

MACHINE DIMENSIONS

MODEL NO.

HEIGHT

WIDTH

DEPTH

LEGEND

1521 [394mm]

A - DRAIN 1 1/2" IPS B - WATER INLET 3/4" IPS C - ELECTRICAL CONNECTION All vertical dimensions are +/- 1/2" due to adjustable bullet feet.

421 [114mm]

DRAIN SHIPPING INFORMATION HEIGHT WEIGHT CLASS CUBE

HEIGHT

WIDTH

DEPTH

TempStar®

64-3/8" (1635 mm)

25-1/4" (641 mm)

25-1/4" (641 mm)

13-1/4" 350 lbs (335 mm) (159 kg)

92.5

37-1/2 cu. ft.

79" (2007 mm)

33" (838 mm)

43" (1092 mm)

DIMENSION REQUIREMENTS

STEAM REQUIREMENTS

Wall Clearance (minimum)

4" (102 mm)

Steam Flow Pressure (PSIG)

Standard Table Height

34" (864 mm)

Consumption @ 15 PSIG (Ibs/hr)

Inside Clearance

17-1/4" (438 mm)

WATER REQUIREMENTS


OPERATING CAPACITY Racks per Hour
OPERATING CYCLE (seconds) Normal Medium Heavy Extra Heavy OPERATING TEMPERATURES Wash (minimum) Rinse (minimum)
WASH PUMP MOTOR
 Wash Pump Motor Horsepower

Normal Medium

58

30

Wash Rinse

40

13

100

13

160

13

280

13

Heavy 20
Dwell 4 4 4
4

Extra Heavy
 12
Total Cycle 57 117 177

297


150° F (66° C) 180° F (82° C)

Inlet Temperature 
 40°F (22.2°C) Rise 70°F (38.9°C) Rise No Booster
Gallons per Hour Gallons per Rack Waterline Size IPS (minimum) Drainline Size IPS (minimum) Flow Pressure (PSI) Wash Tank Capacity Booster Tank Capacity

3/4 HP

APPROXIMATE LOAD AMPS


Volts

KW

Electric Wash Tank Heater Electric Rinse Tank Heater - 40°F (22.2°C) Rise Electric Rinse Tank Heater - 70°F (38.9°C) Rise

208V 230V 460V 208V 230V 460V 208V 230V

4.1

Power Supply

5.0

208V/60HZ/1PH

5.0

208V/60HZ/3PH

9.0

230V/60HZ/1PH

11.0

230V/60HZ/3PH

11.0

460V/60HZ/3PH

10.5

HOW TO SPECIFY: TempStar®

12.9

460V

12.9

15-20 45

140°F (60°C) 110°F (43°C) 180°F (82°C) 52 gal (197 L) .89 gal (3 L)
1/2"
 1- 1/2"

10 8 gal (30 L) 3 gal (11 L)

No Booster
AMPS 24.6 16.3 26.6 17.5 7.9

40°F (22.2°C) Rise AMPS 68.7 42.1 75.4 45.5 21.7

70°F (38.9°C) Rise AMPS 75.8 46.3 83.6 50.7 24.1

Jackson WWS, Inc.
Shipping Address: 6209 North U.S. Highway 25E, Gray, KY 40734 Mailing Address: P.O.Box 1060, Barbourville, KY 40906 Telephone: 888-800-5672 · Fax: 606-523-1799 Email: [email protected] 07610-002-66-59 [03/06/15]

www.jacksonwws.com

We reserve the right to change specifications in this bulletin without incurring any obligation for equipment previously or subsequently sold.


Adobe PDF library 10.01