2408RSU020-U8-FCC IC EMC Test Report
dell
Test Report JBP
ALE USA Inc. OAW-AP152X 2AI9TOAW-AP152X 2AI9TOAWAP152X oaw ap152x
Not Your Device? Search For Manuals or Datasheets below:
File Info : application/pdf, 73 Pages, 1.78MB
Document DEVICE REPORTGetApplicationAttachment.html?id=8009335MRT Technology (Suzhou) Co., Ltd Phone: +86-512-66308358 Web: www.mrt-cert.com Report No.: 2408RSU020-U8 Report Version: V01 Issue Date: 2024-12-27 EMC MEASUREMENT REPORT FCC ID: 2AI9TOAW-AP152X Applicant: ALE USA Inc. Address: 2000 Corporate Center Drive Thousand Oaks, CA 91320 Product: OmniAccess Stellar Model No.: OAW-AP1521 Brand Name: Alcatel-Lucent Enterprise FCC Rule Part(s): FCC Part 15 Subpart B ISED Rule(s): Test Procedure: ICES-003 Issue 7 (October 15, 2020) RSS-Gen Issue 5 ANSI C63.4 - 2014 Result: Complies Received Date: 2024-08-13 Test Date: 2024-10-27 ~ 2024-12-18 Reviewed By: Approved By: Vincent Yu Robin Wu The test results relate only to the samples tested. This equipment has been shown to be capable of compliance with the applicable technical standards as indicated in the measurement report and was tested in accordance with the measurement procedures specified in ANSI C63.4-2014. Test results reported herein relate only to the item(s) tested. The test report shall not be reproduced except in full without the written approval of MRT Technology (Suzhou) Co., Ltd. Template Version:1.6 1 of 73 Report No. 2408RSU020-U8 Version V01 Revision History Description Initial Report Report No.: 2408RSU020-U8 Issue Date 2024-12-27 Note Valid 2 of 73 Report No.: 2408RSU020-U8 Description CONTENTS Page 1. General Information ................................................................................................................................ 4 1.1. Applicant........................................................................................................................................ 4 1.2. Manufacturer ................................................................................................................................. 4 1.3. Testing Facility............................................................................................................................... 4 1.4. Product Information ....................................................................................................................... 5 2. Test Configuration .................................................................................................................................. 6 2.1. Test Mode ..................................................................................................................................... 6 2.2. Configuration of Tested System.................................................................................................... 6 2.3. EMI Suppression Device(s)/Modifications .................................................................................... 8 3. Measuring Instrument ............................................................................................................................ 9 4. Decision Rules and Measurement Uncertainty...................................................................................11 4.1. Decision Rules .............................................................................................................................11 4.2. Measurement Uncertainty ............................................................................................................11 5. Test Result ............................................................................................................................................. 12 5.1. Summary ..................................................................................................................................... 12 5.2. Conducted Emission ................................................................................................................... 13 5.2.1. Test Limit ..................................................................................................................................... 13 5.2.2. Test Setup ................................................................................................................................... 13 5.2.3. Test Result................................................................................................................................... 14 5.3. Radiated Emission ...................................................................................................................... 28 5.3.1. Test Limit ..................................................................................................................................... 28 5.3.2. Test Setup ................................................................................................................................... 29 5.3.3. Test Result................................................................................................................................... 30 Appendix A - Test Setup Photograph .......................................................................................................... 30 Appendix B - EUT Photograph ..................................................................................................................... 73 3 of 73 1. General Information 1.1. Applicant ALE USA Inc. 2000 Corporate Center Drive Thousand Oaks, CA 91320 Report No.: 2408RSU020-U8 1.2. Manufacturer ALE USA Inc. 2000 Corporate Center Drive Thousand Oaks, CA 91320 1.3. Testing Facility Test Site MRT Suzhou Laboratory Laboratory Location (Suzhou - Wuzhong) D8 Building, No.2 Tian'edang Rd., Wuzhong Economic Development Zone, Suzhou, China Laboratory Location (Suzhou - SIP) 4b Building, Liando U Valley, No.200 Xingpu Rd., Shengpu Town, Suzhou Industrial Park, China Laboratory Location (Suzhou - Wujiang) Building 1, No.1 Xingdong Road, Wujiang, Suzhou, Jiangsu, People's Republic of China Laboratory Accreditations A2LA: 3628.01 CNAS: L10551 FCC: CN1166 ISED: CN0001 VCCI: R-20025 R-20141 G-20034 G-20134 C-20020 C-20103 T-20020 T-20104 Test Site MRT Shenzhen Laboratory Laboratory Location (Shenzhen) 1G, Building A, Junxiangda Building, Zhongshanyuan Road West, Nanshan District, Shenzhen, China Laboratory Accreditations A2LA: 3628.02 CNAS: L10551 FCC: CN1284 ISED: CN0105 Test Site MRT Taiwan Laboratory Laboratory Location (Taiwan) No. 38, Fuxing 2nd Rd., Guishan Dist., Taoyuan City 333, Taiwan (R.O.C.) Laboratory Accreditations TAF: 3261 FCC: 291082, TW3261 ISED: TW3261 4 of 73 Report No.: 2408RSU020-U8 1.4. Product Information Product Name OmniAccess Stellar Model No. OAW-AP1521 20240819Sample#17 (Mode 1) EUT Identification No. 20241104Sample#02 (Mode 2) 20240819Sample#16 & 20240819Sample#17 (Mode 3 ~ 7) Wi-Fi Specification 802.11a/b/g/n/ac/ax/be Zigbee Specification 802.15.4 Bluetooth Specification V5.1 Single Mode Power Type AC/DC Adapter Input or PoE Input Operating Environment Indoor Use Accessories AC/DC Adapter Model: ADP-50GR B Input: 100-240V ~ 50/60Hz, 1.3A Output: 48.0V, 1.042A, 50.1W MAX PoE Injector Model: POE60U-1BT-X (ALE P/N: POE60U-1BT-X-R) Input: 100-240V ~ 1.5A, 50/60Hz Output: 56.0V, 0.535A, 30W PIN 3, 6+ PIN 1, 2 Return Output: 56.0V, 0.535A, 30W PIN 4, 5+ PIN 7, 8 Return Notes: 1. The information of EUT was provided by the manufacturer, and the accuracy of the information shall be the responsibility of the manufacturer. 2. AC/DC Adapter and PoE Injector are not sold with product. 5 of 73 Report No.: 2408RSU020-U8 2. Test Configuration 2.1. Test Mode Mode 1: OAW-AP1521 powered by adapter + Ethernet port connect to computer via LAN cable + Connect to mobile phone via 2.4G/5G/6G Wi-Fi + Connect to mobile phone via BLE + Plug USB flash and make it reading/writing. Mode 2: OAW-AP1521 powered by PoE and connect to notebook via LAN cable + Connect to mobile phone via 2.4G/5G/6G Wi-Fi + Connect to signal generator via Zigbee + Plug USB flash and make it reading/writing. Mode 3: OAW-AP1521 powered by adapter Ethernet port connect to computer via LAN cable + Plug USB flash + Make EUT in 2.4GHz Wi-Fi receiving mode. Mode 4: OAW-AP1521 powered by adapter Ethernet port connect to computer via LAN cable + Plug USB flash + Make EUT in 5GHz Wi-Fi receiving mode. Mode 5: OAW-AP1521 powered by adapter Ethernet port connect to computer via LAN cable + Plug USB flash + Make EUT in 6GHz Wi-Fi receiving mode. Mode 6: OAW-AP1521 powered by adapter Ethernet port connect to computer via LAN cable + Plug USB flash + Make EUT in BLE receiving mode. Mode 7: OAW-AP1521 powered by adapter Ethernet port connect to computer via LAN cable + Plug USB flash + Make EUT in Zigbee receiving mode. 2.2. Configuration of Tested System The measurement procedures and appropriate EUT setup described in the ANSI C63.4-2014 was used in the measurement. Mode 1 6 of 73 Mode 2 Report No.: 2408RSU020-U8 Mode 3 ~ 7 No. Cable Type A DC Power Cable B LAN Cable C LAN Cable No. Product 1 USB Flash 2 Mobile Phone 3 Mobile Phone 4 Mobile Phone 5 Mobile Phone Cable Spec. Shielding Non-Shielding, Cat 6 Non-Shielding, Cat 5e Manufacturer Samsung Apple Apple VIVO OPPO 7 of 73 Length 1.6m >10.0m >10.0m Model No. 64G iPhone 6S iPhone 13 X90 Pro X9009 6 Computer 7 Signal Generator 8 Notebook HP R&S Lenovo Report No.: 2408RSU020-U8 ZHAN 66 SMU200A Thinkbook16 2.3. EMI Suppression Device(s)/Modifications No EMI suppression device(s) were added and/or no modifications were made during testing. 8 of 73 Report No.: 2408RSU020-U8 3. Measuring Instrument Instrument Name EMI Test Receiver Horn Antenna Horn Antenna Preamplifier TRILOG Antenna Anechoic Chamber Signal Analyzer Thermohygrometer Preamplifier TRILOG Antenna EMI Test Receiver Horn Antenna Preamplifier Anechoic Chamber Thermohygrometer Two-Line V-Network Shielding Room Thermohygrometer EMI Test Receiver Four-Line V-Network Preamplifier Horn Antenna Thermohygrometer Preamplifier TRILOG Antenna Anechoic Chamber Preamplifier Horn Antenna Signal Analyzer Signal Analyzer Two-Line V-Network EMI Test Receiver Thermohygrometer Shielding Room Four-Line V-Network Manufacturer R&S Schwarzbeck Schwarzbeck Agilent Schwarzbeck TDK Keysight testo EMCI Schwarzbeck Agilent Schwarzbeck Schwarzbeck RIKEN testo R&S MIX-BEP testo R&S R&S Schwarzbeck R&S testo EMCI Schwarzbeck RIKEN EMCI Schwarzbeck Keysight Keysight R&S R&S testo MIX-BEP R&S Model No. ESR7 BBHA 9120D BBHA 9170 83017A VULB 9168 WZ-AC1 N9010B 608-H1 EMC184045SE VULB 9162 N9038A BBHA 9120D BBV 9718 WZ-AC2 608-H1 ENV216 WZ-SR2 608-H1 ESR3 ENV432 BBV 9721 HF907 608-H1 EMC012645SE VULB 9168 SIP-AC3 EMC184045SE BBHA 9170 N9010B N9020B ENV216 ESR3 608-H1 SIP-SR2 ENV432 Asset No. MRTSUE06001 MRTSUE06023 MRTSUE06024 MRTSUE06076 MRTSUE06172 MRTSUE06212 MRTSUE06607 MRTSUE11039 MRTSUE06640 MRTSUE06022 MRTSUE06125 MRTSUE06171 MRTSUE06176 MRTSUE06213 MRTSUE11263 MRTSUE06002 MRTSUE06215 MRTSUE06404 MRTSUE06909 MRTSUE06615 MRTSUE06121 MRTSUE06611 MRTSUE06619 MRTSUE06642 MRTSUE06646 MRTSUE06782 MRTSUE06602 MRTSUE06599 MRTSUE06603 MRTSUE06604 MRTSUE06003 MRTSUE06612 MRTSUE06621 MRTSUE06949 MRTSUE06614 9 of 73 Cali. Interval 1 year 1 year 1 year 1 year 1 year 1 year 1 year 1 year 1 year 1 year 1 year 1 year 1 year 1 year 1 year 1 year 5 years 1 year 1 year 1 year 1 year 1 year 1 year 1 year 1 year 1 year 1 year 1 year 1 year 1 year 1 year 1 year 1 year 5 years 1 year Cal. Due Date Test Site 2025-12-05 WZ-AC1 2025-07-26 WZ-AC1 2025-09-23 WZ-AC1 2025-11-08 WZ-AC1 2025-05-15 WZ-AC1 2025-04-19 WZ-AC1 2025-10-13 WZ-AC1 2025-10-16 WZ-AC1 2025-01-11 WZ-AC1 2025-04-17 WZ-AC2 2025-05-08 WZ-AC2 2025-09-23 WZ-AC2 2025-05-06 WZ-AC2 2025-04-18 WZ-AC2 2025-10-16 WZ-AC2 2025-05-08 WZ-SR2 2026-12-20 WZ-SR2 2025-05-12 WZ-SR2 2025-09-05 WZ-SR2 2025-09-05 WZ-SR2 2025-06-06 SIP-AC3 2025-07-07 SIP-AC3 2025-10-16 SIP-AC3 2025-01-11 SIP-AC3 2025-07-29 SIP-AC3 2025-12-20 SIP-AC3 2025-10-08 SIP-AC3 2025-09-08 SIP-AC3 2025-09-05 SIP-AC3 2025-02-03 SIP-AC3 2025-05-08 SIP-SR2 2025-05-08 SIP-SR2 2025-10-29 SIP-SR2 2029-10-13 SIP-SR2 2025-10-13 SIP-SR2 Software e3 Controller_MF 7802 Controller_MF 7802 Controller_MF 7802BS Version 230711 2.03C 1.02 1.02 Report No.: 2408RSU020-U8 Function RE & CE RE Antenna & turntable RE Antenna & Turntable RE Antenna & Turntable 10 of 73 Report No.: 2408RSU020-U8 4. Decision Rules and Measurement Uncertainty 4.1. Decision Rules The Decision Rule is based on Simple Acceptance in accordance with ISO Guide 98-4: 2012 Clause 8.2. (Measurement uncertainty is not taken into account when stating conformity with a specified requirement.) 4.2. Measurement Uncertainty Where relevant, the following test uncertainty levels have been estimated for tests performed on the EUT as specified in CISPR 16-4-2. This uncertainty represents an expanded uncertainty expressed at approximately the 95% confidence level using a coverage factor of k = 2. Conducted Emission Measurement The maximum measurement uncertainty is evaluated as: 9kHz~150kHz: 3.02dB 150kHz~30MHz: 2.56dB Radiated Emission Measurement The maximum measurement uncertainty is evaluated as: Horizontal: 30MHz~200MHz: 3.46dB 200MHz~1GHz: 3.78dB 1GHz~40GHz: 4.97dB Vertical: 30MHz~200MHz: 4.07dB 200MHz~1GHz: 5.28dB 1GHz~40GHz: 4.78dB 11 of 73 5. Test Result 5.1. Summary FCC Part Section(s) 15.107 15.109 ISED Section(s) ICES-003 - 3.2.1 RSS-Gen - 7.2 ICES-003 - 3.2.2 RSS-Gen - 7.3 Report No.: 2408RSU020-U8 Test Description Conducted Emission Radiated Emission Result Pass Pass 12 of 73 Report No.: 2408RSU020-U8 5.2. Conducted Emission 5.2.1. Test Limit Frequency Range (MHz) 0.15 ~ 0.5 0.5 ~ 5 5 ~ 30 FCC Part 15.107 / ICES-003 Conducted Emission Limits Class A Limits Class B Limits QP dB(V) 79 AV dB(V) 66 QP dB(V) 66 to 56 AV dB(V) 56 to 46 73 60 56 46 73 60 60 50 Frequency Range (MHz) 0.15 ~ 0.5 0.5 ~ 5 5 ~ 30 RSS-Gen Receiver Conducted Emission Limits QP dB(V) 66 to 56 56 60 AV dB(V) 56 to 46 46 50 5.2.2. Test Setup 13 of 73 Report No.: 2408RSU020-U8 5.2.3. Test Result Site Test Engineer Factor EUT Test Mode WZ-SR2 Linda Wei ENV216_101683_L1_Filter Off_C OmniAccess Stellar (OAW-AP1521) Mode 1, Power Port Test Date Temp./Humidity Polarity Test Voltage 2024-10-28 22.8C/66.0% Line AC 120V/60Hz Frequency No Mark (MHz) Reading (dBV) C.F Measurement (dB) (dBV) 1 0.150 26.70 9.82 36.52 2 * 0.150 45.30 9.82 55.12 3 0.202 14.80 9.82 24.62 4 0.202 35.70 9.82 45.52 5 0.384 20.80 9.88 30.68 6 0.384 29.60 9.88 39.48 7 1.370 9.60 10.12 19.72 8 1.370 17.30 10.12 27.42 9 7.200 13.90 10.26 24.16 10 7.200 20.00 10.26 30.26 11 13.850 16.40 10.50 26.90 12 13.850 21.80 10.50 32.30 Notes: 1. " * ", means this data is the worst emission level. 2. C.F (dB) = LISN Factor (dB) + Cable Loss (dB). 3. Measurement (dBV) = Reading (dBV) + C.F (dB). 14 of 73 Margin (dB) -19.48 -10.88 -28.91 -18.01 -17.51 -18.71 -26.28 -28.58 -25.84 -29.74 -23.10 -27.70 Limit (dBV) 56.00 66.00 53.53 63.53 48.19 58.19 46.00 56.00 50.00 60.00 50.00 60.00 Detector Average QP Average QP Average QP Average QP Average QP Average QP Report No.: 2408RSU020-U8 Site Test Engineer Factor EUT Test Mode WZ-SR2 Linda Wei ENV216_101683_N_Filter Off_C OmniAccess Stellar (OAW-AP1521) Mode 1, Power Port Test Date Temp./Humidity Polarity Test Voltage 2024-10-28 22.8C/66.0% Neutral AC 120V/60Hz Frequency No Mark (MHz) Reading (dBV) C.F Measurement (dB) (dBV) 1 0.152 27.00 10.13 37.13 2 * 0.152 44.10 10.13 54.23 3 0.165 21.50 10.12 31.62 4 0.165 41.60 10.12 51.72 5 0.383 21.20 10.13 31.33 6 0.383 29.60 10.13 39.73 7 1.200 10.30 10.38 20.68 8 1.200 18.50 10.38 28.88 9 13.860 15.00 10.77 25.77 10 13.860 20.70 10.77 31.47 11 16.940 15.70 10.98 26.68 12 16.940 22.30 10.98 33.28 Notes: 1. " * ", means this data is the worst emission level. 2. C.F (dB) = LISN Factor (dB) + Cable Loss (dB). 3. Measurement (dBV) = Reading (dBV) + C.F (dB). 15 of 73 Margin (dB) -18.76 -11.66 -23.59 -13.49 -16.88 -18.48 -25.32 -27.12 -24.23 -28.53 -23.32 -26.72 Limit (dBV) 55.89 65.89 55.21 65.21 48.21 58.21 46.00 56.00 50.00 60.00 50.00 60.00 Detector Average QP Average QP Average QP Average QP Average QP Average QP Report No.: 2408RSU020-U8 Site Test Engineer Factor EUT Test Mode WZ-SR2 Linda Wei ENV216_101683_L1_Filter Off_C OmniAccess Stellar (OAW-AP1521) Mode 2, Power Port Test Date Temp./Humidity Polarity Test Voltage 2024-11-04 22.5C/65.2% Line AC 120V/60Hz Frequency No Mark (MHz) Reading (dBV) C.F Measurement (dB) (dBV) 1 0.158 21.60 9.82 31.42 2 * 0.158 38.80 9.82 48.62 3 0.178 18.40 9.82 28.22 4 0.178 35.70 9.82 45.52 5 0.514 -5.60 9.93 4.33 6 0.514 9.20 9.93 19.13 7 2.900 -4.00 10.15 6.15 8 2.900 6.40 10.15 16.55 9 13.260 12.30 10.48 22.78 10 13.260 18.00 10.48 28.48 11 24.140 14.10 10.89 24.99 12 24.140 18.60 10.89 29.49 Notes: 1. " * ", means this data is the worst emission level. 2. C.F (dB) = LISN Factor (dB) + Cable Loss (dB). 3. Measurement (dBV) = Reading (dBV) + C.F (dB). 16 of 73 Margin (dB) -24.15 -16.95 -26.36 -19.06 -41.67 -36.87 -39.85 -39.45 -27.22 -31.52 -25.01 -30.51 Limit (dBV) 55.57 65.57 54.58 64.58 46.00 56.00 46.00 56.00 50.00 60.00 50.00 60.00 Detector Average QP Average QP Average QP Average QP Average QP Average QP Report No.: 2408RSU020-U8 Site Test Engineer Factor EUT Test Mode WZ-SR2 Linda Wei ENV216_101683_N_Filter Off_C OmniAccess Stellar (OAW-AP1521) Mode 2, Power Port Test Date Temp./Humidity Polarity Test Voltage 2024-11-04 22.5C/65.2% Neutral AC 120V/60Hz Frequency No Mark (MHz) Reading (dBV) C.F Measurement (dB) (dBV) 1 0.150 20.80 10.13 30.93 2 * 0.150 39.50 10.13 49.63 3 0.178 17.80 10.11 27.91 4 0.178 35.40 10.11 45.51 5 0.204 13.20 10.10 23.30 6 0.204 31.40 10.10 41.50 7 2.980 -3.50 10.41 6.91 8 2.980 8.60 10.41 19.01 9 13.530 11.80 10.76 22.56 10 13.530 17.70 10.76 28.46 11 24.140 14.50 11.13 25.63 12 24.140 18.40 11.13 29.53 Notes: 1. " * ", means this data is the worst emission level. 2. C.F (dB) = LISN Factor (dB) + Cable Loss (dB). 3. Measurement (dBV) = Reading (dBV) + C.F (dB). 17 of 73 Margin (dB) -25.07 -16.37 -26.66 -19.06 -30.14 -21.94 -39.10 -37.00 -27.44 -31.54 -24.37 -30.47 Limit (dBV) 56.00 66.00 54.58 64.58 53.45 63.45 46.00 56.00 50.00 60.00 50.00 60.00 Detector Average QP Average QP Average QP Average QP Average QP Average QP Report No.: 2408RSU020-U8 Site Test Engineer Factor EUT Test Mode SIP-SR2 Henry Wang SIP-SR2-ENV216_101684_C OmniAccess Stellar (OAW-AP1521) Mode 3, Power Port Test Date Temp./Humidity Polarity Test Voltage 2024-11-12 22.1C/60.6% Line AC 120V/60Hz Frequency No Mark (MHz) Reading (dBV) C.F Measurement (dB) (dBV) 1 0.154 23.57 9.65 33.22 2 * 0.154 42.01 9.65 51.66 3 0.166 17.83 9.66 27.49 4 0.166 39.73 9.66 49.38 5 0.178 19.16 9.66 28.82 6 0.178 38.54 9.66 48.19 7 0.186 16.98 9.67 26.65 8 0.186 37.22 9.67 46.89 9 0.194 14.05 9.68 23.73 10 0.194 35.02 9.68 44.70 11 0.382 23.10 9.74 32.84 12 0.382 30.79 9.74 40.53 Notes: 1. " * ", means this data is the worst emission level. 2. C.F (dB) = LISN Factor (dB) + Cable Loss (dB). 3. Measurement (dBV) = Reading (dBV) + C.F (dB). 18 of 73 Margin (dB) -22.56 -14.12 -27.67 -15.78 -25.76 -16.38 -27.57 -17.33 -30.14 -19.17 -15.40 -17.71 Limit (dBV) 55.78 65.78 55.16 65.16 54.58 64.58 54.21 64.21 53.86 63.86 48.24 58.24 Detector Average QP Average QP Average QP Average QP Average QP Average QP Report No.: 2408RSU020-U8 Site Test Engineer Factor EUT Test Mode SIP-SR2 Henry Wang SIP-SR2-ENV216_101684_C OmniAccess Stellar (OAW-AP1521) Mode 3, Power Port Test Date Temp./Humidity Polarity Test Voltage 2024-11-12 22.1C/60.6% Neutral AC 120V/60Hz Frequency No Mark (MHz) Reading (dBV) C.F Measurement (dB) (dBV) 1 0.154 24.38 9.68 34.06 2 * 0.154 41.79 9.68 51.47 3 0.182 20.37 9.68 30.05 4 0.182 38.66 9.68 48.35 5 0.190 16.77 9.69 26.47 6 0.190 36.53 9.69 46.22 7 0.206 14.62 9.72 24.34 8 0.206 34.04 9.72 43.76 9 0.378 23.45 9.76 33.21 10 0.378 31.03 9.76 40.78 11 16.817 16.36 10.21 26.57 12 16.817 22.56 10.21 32.78 Notes: 1. " * ", means this data is the worst emission level. 2. C.F (dB) = LISN Factor (dB) + Cable Loss (dB). 3. Measurement (dBV) = Reading (dBV) + C.F (dB). 19 of 73 Margin (dB) -21.72 -14.31 -24.34 -16.05 -27.57 -17.81 -29.03 -19.61 -15.12 -17.54 -23.43 -27.22 Limit (dBV) 55.78 65.78 54.39 64.39 54.04 64.04 53.37 63.37 48.32 58.32 50.00 60.00 Detector Average QP Average QP Average QP Average QP Average QP Average QP Report No.: 2408RSU020-U8 Site Test Engineer Factor EUT Test Mode SIP-SR2 Henry Wang SIP-SR2-ENV216_101684_C OmniAccess Stellar (OAW-AP1521) Mode 4, Power Port Test Date Temp./Humidity Polarity Test Voltage 2024-11-12 22.1C/60.6% Line AC 120V/60Hz Frequency No Mark (MHz) Reading (dBV) C.F Measurement (dB) (dBV) 1 0.158 22.94 9.65 32.59 2 * 0.158 41.47 9.65 51.12 3 0.166 20.07 9.66 29.72 4 0.166 40.88 9.66 50.54 5 0.182 17.87 9.66 27.54 6 0.182 37.49 9.66 47.15 7 0.194 13.74 9.68 23.42 8 0.194 34.67 9.68 44.35 9 0.202 13.60 9.69 23.29 10 0.202 34.02 9.69 43.71 11 0.374 23.12 9.74 32.86 12 0.374 30.70 9.74 40.43 Notes: 1. " * ", means this data is the worst emission level. 2. C.F (dB) = LISN Factor (dB) + Cable Loss (dB). 3. Measurement (dBV) = Reading (dBV) + C.F (dB). 20 of 73 Margin (dB) -22.98 -14.45 -25.44 -14.62 -26.86 -17.24 -30.44 -19.51 -30.24 -19.82 -15.56 -17.98 Limit (dBV) 55.57 65.57 55.16 65.16 54.39 64.39 53.86 63.86 53.53 63.53 48.41 58.41 Detector Average QP Average QP Average QP Average QP Average QP Average QP Report No.: 2408RSU020-U8 Site Test Engineer Factor EUT Test Mode SIP-SR2 Henry Wang SIP-SR2-ENV216_101684_C OmniAccess Stellar (OAW-AP1521) Mode 4, Power Port Test Date Temp./Humidity Polarity Test Voltage 2024-11-12 22.1C/60.6% Neutral AC 120V/60Hz Frequency No Mark (MHz) Reading (dBV) C.F Measurement (dB) (dBV) 1 0.154 24.33 9.68 34.01 2 * 0.154 41.68 9.68 51.36 3 0.162 22.05 9.68 31.73 4 0.162 41.16 9.68 50.84 5 0.174 19.90 9.68 29.58 6 0.174 39.06 9.68 48.74 7 0.190 16.60 9.69 26.29 8 0.190 36.34 9.69 46.03 9 0.385 23.27 9.76 33.03 10 0.385 31.04 9.76 40.80 11 16.581 16.48 10.21 26.69 12 16.581 22.66 10.21 32.87 Notes: 1. " * ", means this data is the worst emission level. 2. C.F (dB) = LISN Factor (dB) + Cable Loss (dB). 3. Measurement (dBV) = Reading (dBV) + C.F (dB). 21 of 73 Margin (dB) -21.78 -14.43 -23.64 -14.52 -25.19 -16.02 -27.75 -18.00 -15.13 -17.36 -23.31 -27.13 Limit (dBV) 55.79 65.79 55.36 65.36 54.77 64.77 54.04 64.04 48.16 58.16 50.00 60.00 Detector Average QP Average QP Average QP Average QP Average QP Average QP Report No.: 2408RSU020-U8 Site Test Engineer Factor EUT Test Mode SIP-SR2 Henry Wang SIP-SR2-ENV216_101684_C OmniAccess Stellar (OAW-AP1521) Mode 5, Power Port Test Date Temp./Humidity Polarity Test Voltage 2024-11-12 22.1C/60.6% Line AC 120V/60Hz Frequency No Mark (MHz) Reading (dBV) C.F Measurement (dB) (dBV) 1 0.154 23.19 9.65 32.84 2 * 0.154 41.48 9.65 51.13 3 0.162 20.85 9.65 30.51 4 0.162 41.02 9.65 50.67 5 0.174 18.49 9.66 28.15 6 0.174 38.90 9.66 48.55 7 0.190 15.10 9.67 24.77 8 0.190 36.20 9.67 45.88 9 0.198 13.62 9.68 23.30 10 0.198 34.55 9.68 44.24 11 0.386 23.23 9.74 32.97 12 0.386 30.77 9.74 40.51 Notes: 1. " * ", means this data is the worst emission level. 2. C.F (dB) = LISN Factor (dB) + Cable Loss (dB). 3. Measurement (dBV) = Reading (dBV) + C.F (dB). 22 of 73 Margin (dB) -22.94 -14.65 -24.85 -14.69 -26.62 -16.22 -29.26 -18.16 -30.39 -19.46 -15.18 -17.64 Limit (dBV) 55.78 65.78 55.36 65.36 54.77 64.77 54.04 64.04 53.69 63.69 48.15 58.15 Detector Average QP Average QP Average QP Average QP Average QP Average QP Report No.: 2408RSU020-U8 Site Test Engineer Factor EUT Test Mode SIP-SR2 Henry Wang SIP-SR2-ENV216_101684_C OmniAccess Stellar (OAW-AP1521) Mode 5, Power Port Test Date Temp./Humidity Polarity Test Voltage 2024-11-12 22.1C/60.6% Neutral AC 120V/60Hz Frequency No Mark (MHz) Reading (dBV) C.F Measurement (dB) (dBV) 1 0.150 23.52 9.68 33.21 2 0.150 41.27 9.68 50.95 3 0.166 21.46 9.68 31.14 4 * 0.166 40.65 9.68 50.33 5 0.178 20.10 9.68 29.78 6 0.178 37.89 9.68 47.57 7 0.194 14.93 9.70 24.63 8 0.194 34.45 9.70 44.15 9 0.202 14.53 9.71 24.24 10 0.202 33.76 9.71 43.47 11 0.374 23.48 9.76 33.23 12 0.374 31.05 9.76 40.80 Notes: 1. " * ", means this data is the worst emission level. 2. C.F (dB) = LISN Factor (dB) + Cable Loss (dB). 3. Measurement (dBV) = Reading (dBV) + C.F (dB). 23 of 73 Margin (dB) -22.79 -15.05 -24.02 -14.82 -24.80 -17.01 -29.23 -19.72 -29.29 -20.06 -15.18 -17.61 Limit (dBV) 56.00 66.00 55.16 65.16 54.58 64.58 53.86 63.86 53.53 63.53 48.41 58.41 Detector Average QP Average QP Average QP Average QP Average QP Average QP Report No.: 2408RSU020-U8 Site Test Engineer Factor EUT Test Mode SIP-SR2 Henry Wang SIP-SR2-ENV216_101684_C OmniAccess Stellar (OAW-AP1521) Mode 6, Power Port Test Date Temp./Humidity Polarity Test Voltage 2024-11-12 22.1C/60.6% Line AC 120V/60Hz Frequency No Mark (MHz) Reading (dBV) C.F Measurement (dB) (dBV) 1 0.158 23.52 9.65 33.18 2 * 0.158 42.07 9.65 51.73 3 0.174 19.05 9.66 28.71 4 0.174 39.61 9.66 49.26 5 0.182 18.32 9.66 27.98 6 0.182 38.07 9.66 47.73 7 0.194 14.24 9.68 23.92 8 0.194 35.26 9.68 44.94 9 0.202 14.05 9.69 23.74 10 0.202 34.55 9.69 44.24 11 0.378 23.13 9.74 32.86 12 0.378 30.77 9.74 40.51 Notes: 1. " * ", means this data is the worst emission level. 2. C.F (dB) = LISN Factor (dB) + Cable Loss (dB). 3. Measurement (dBV) = Reading (dBV) + C.F (dB). 24 of 73 Margin (dB) -22.39 -13.84 -26.06 -15.50 -26.41 -16.66 -29.94 -18.93 -29.79 -19.29 -15.46 -17.82 Limit (dBV) 55.57 65.57 54.77 64.77 54.39 64.39 53.86 63.86 53.53 63.53 48.32 58.32 Detector Average QP Average QP Average QP Average QP Average QP Average QP Report No.: 2408RSU020-U8 Site Test Engineer Factor EUT Test Mode SIP-SR2 Henry Wang SIP-SR2-ENV216_101684_C OmniAccess Stellar (OAW-AP1521) Mode 6, Power Port Test Date Temp./Humidity Polarity Test Voltage 2024-11-12 22.1C/60.6% Neutral AC 120V/60Hz Frequency No Mark (MHz) Reading (dBV) C.F Measurement (dB) (dBV) 1 0.158 24.56 9.68 34.24 2 * 0.158 42.26 9.68 51.94 3 0.166 19.01 9.68 28.69 4 0.166 40.00 9.68 49.68 5 0.174 20.61 9.68 30.29 6 0.174 39.76 9.68 49.44 7 0.186 18.59 9.69 28.27 8 0.186 37.55 9.69 47.24 9 0.378 23.33 9.76 33.09 10 0.378 31.00 9.76 40.76 11 16.389 15.53 10.21 25.74 12 16.389 21.70 10.21 31.91 Notes: 1. " * ", means this data is the worst emission level. 2. C.F (dB) = LISN Factor (dB) + Cable Loss (dB). 3. Measurement (dBV) = Reading (dBV) + C.F (dB). 25 of 73 Margin (dB) -21.33 -13.63 -26.47 -15.48 -24.48 -15.33 -25.94 -16.98 -15.23 -17.56 -24.26 -28.09 Limit (dBV) 55.57 65.57 55.16 65.16 54.77 64.77 54.21 64.21 48.32 58.32 50.00 60.00 Detector Average QP Average QP Average QP Average QP Average QP Average QP Report No.: 2408RSU020-U8 Site Test Engineer Factor EUT Test Mode SIP-SR2 Henry Wang SIP-SR2-ENV216_101684_C OmniAccess Stellar (OAW-AP1521) Mode 7, Power Port Test Date Temp./Humidity Polarity Test Voltage 2024-11-12 22.1C/60.6% Line AC 120V/60Hz Frequency No Mark (MHz) Reading (dBV) C.F Measurement (dB) (dBV) 1 0.154 24.53 9.65 34.18 2 * 0.154 43.28 9.65 52.93 3 0.166 20.70 9.66 30.36 4 0.166 42.25 9.66 51.90 5 0.178 20.17 9.66 29.83 6 0.178 40.49 9.66 50.15 7 0.186 17.76 9.67 27.43 8 0.186 38.25 9.67 47.91 9 0.194 16.75 9.68 26.43 10 0.194 37.92 9.68 47.60 11 0.374 22.95 9.74 32.68 12 0.374 30.75 9.74 40.49 Notes: 1. " * ", means this data is the worst emission level. 2. C.F (dB) = LISN Factor (dB) + Cable Loss (dB). 3. Measurement (dBV) = Reading (dBV) + C.F (dB). 26 of 73 Margin (dB) -21.60 -12.85 -24.80 -13.26 -24.75 -14.43 -26.78 -16.30 -27.43 -16.26 -15.73 -17.92 Limit (dBV) 55.78 65.78 55.16 65.16 54.58 64.58 54.21 64.21 53.86 63.86 48.41 58.41 Detector Average QP Average QP Average QP Average QP Average QP Average QP Report No.: 2408RSU020-U8 Site Test Engineer Factor EUT Test Mode SIP-SR2 Henry Wang SIP-SR2-ENV216_101684_C OmniAccess Stellar (OAW-AP1521) Mode 7, Power Port Test Date Temp./Humidity Polarity Test Voltage 2024-11-12 22.1C/60.6% Neutral AC 120V/60Hz Frequency No Mark (MHz) Reading (dBV) C.F Measurement (dB) (dBV) 1 0.154 24.95 9.68 34.63 2 * 0.154 42.74 9.68 52.42 3 0.162 23.76 9.68 33.44 4 0.162 42.27 9.68 51.95 5 0.174 21.02 9.68 30.70 6 0.174 40.14 9.68 49.82 7 0.190 17.22 9.69 26.91 8 0.190 37.31 9.69 47.00 9 0.378 23.30 9.76 33.06 10 0.378 30.86 9.76 40.62 11 16.569 16.25 10.21 26.46 12 16.569 22.40 10.21 32.61 Notes: 1. " * ", means this data is the worst emission level. 2. C.F (dB) = LISN Factor (dB) + Cable Loss (dB). 3. Measurement (dBV) = Reading (dBV) + C.F (dB). 27 of 73 Margin (dB) -21.15 -13.36 -21.92 -13.41 -24.07 -14.95 -27.13 -17.04 -15.26 -17.71 -23.54 -27.39 Limit (dBV) 55.78 65.78 55.36 65.36 54.77 64.77 54.04 64.04 48.32 58.32 50.00 60.00 Detector Average QP Average QP Average QP Average QP Average QP Average QP Report No.: 2408RSU020-U8 5.3. Radiated Emission 5.3.1. Test Limit FCC Part 15.109 / RSS-Gen / ICES-003 Issue 7 - 3.2.2 Class B Limits Frequency Distance Level Detector (MHz) (m) (dBV/m) Function 30 - 88 3 40 Quasi-peak 88 - 216 3 43.5 Quasi-peak 216 - 230 3 46 Quasi-peak 230 - 960 3 46 / 47 Note 3 Quasi-peak 960 - 1000 3 54 Quasi-peak Above 1000 3 54 Average 74 Peak Note 1: The lower limit shall apply at the transition frequency. Note 2: Distance refers to the distance in meters between the measuring instrument antenna and the closed point of any part of the device or system. Note 3: In the range of 230MHz to 960MHz, the limit of FCC Part 15.109 is more stringent than the limit of ICES-003 Issue 7 and RSS-Gen, so only the limit of FCC Part 15.109 is shown in the test data. 28 of 73 5.3.2. Test Setup Below 1GHz Test Setup: Report No.: 2408RSU020-U8 Above 1GHz Test Setup: 29 of 73 Report No.: 2408RSU020-U8 5.3.3. Test Result Site Test Engineer Factor EUT Test Mode WZ-AC1 Dick Shen VULB 9168_25-1000MHz OmniAccess Stellar (OAW-AP1521) Mode 1 Test Date Temp./Humidity Polarity Test Voltage 2024-10-27 26.1C/53.2% Horizontal AC 120V/60Hz Frequency No Mark (MHz) Reading (dBV) C.F (dB/m) Measurement (dBV/m) 1 171.453 6.82 18.11 24.93 2 368.628 9.76 20.47 30.23 3 422.058 6.79 21.87 28.66 4 800.101 8.49 29.38 37.87 5 * 841.539 10.41 29.59 40.00 6 961.700 13.10 30.82 43.92 Notes: 1. " * ", means this data is the worst emission level. 2. C.F (dB/m) = Antenna Factor (dB/m) + Cable Loss (dB). 3. Measurement(dBV/m) = Reading(dBV) + C.F (dB/m). Margin (dB) -18.57 -15.77 -17.34 -8.13 -6.00 -10.08 Limit (dBV/m) 43.50 46.00 46.00 46.00 46.00 54.00 Detector QP QP QP QP QP QP 30 of 73 Report No.: 2408RSU020-U8 Site Test Engineer Factor EUT Test Mode WZ-AC1 Dick Shen VULB 9168_25-1000MHz OmniAccess Stellar (OAW-AP1521) Mode 1 Test Date Temp./Humidity Polarity Test Voltage 2024-10-27 26.1C/53.2% Vertical AC 120V/60Hz Frequency No Mark (MHz) Reading (dBV) C.F (dB/m) Measurement (dBV/m) 1 * 46.601 13.60 18.36 31.96 2 170.493 9.59 18.17 27.76 3 250.038 14.82 16.95 31.78 4 294.320 6.54 18.66 25.20 5 498.375 3.50 23.55 27.05 6 961.825 2.48 30.82 33.30 Notes: 1. " * ", means this data is the worst emission level. 2. C.F (dB/m) = Antenna Factor (dB/m) + Cable Loss (dB). 3. Measurement(dBV/m) = Reading(dBV) + C.F (dB/m). Margin (dB) -8.04 -15.74 -14.22 -20.80 -18.95 -20.70 Limit (dBV/m) 40.00 43.50 46.00 46.00 46.00 54.00 Detector QP QP QP QP QP QP 31 of 73 Report No.: 2408RSU020-U8 Site Test Engineer Factor EUT Test Mode WZ-AC1 Dick Shen BBHA 9120D_1167_1-18GHz OmniAccess Stellar (OAW-AP1521) Mode 1 Test Date Temp./Humidity Polarity Test Voltage 2024-10-27 26.1C/53.2% Horizontal AC 120V/60Hz Frequency No Mark (MHz) Reading (dBV) C.F (dB/m) Measurement (dBV/m) 1 * 9690.400 31.20 14.04 45.24 2 9690.400 35.76 14.04 49.80 3 14251.500 27.80 15.73 43.53 4 14251.500 35.08 15.73 50.82 5 17935.400 21.00 21.95 42.95 6 17935.400 36.16 21.95 58.11 Notes: 1. " * ", means this data is the worst emission level. 2. C.F (dB/m) = Antenna Factor (dB/m) + Cable Loss (dB) - AMP (dB). 3. Measurement(dBV/m) = Reading(dBV) + C.F (dB/m). Margin (dB) -8.76 -24.20 -10.47 -23.18 -11.05 -15.89 Limit (dBV/m) 54.00 74.00 54.00 74.00 54.00 74.00 Detector Average Peak Average Peak Average Peak 32 of 73 Report No.: 2408RSU020-U8 Site Test Engineer Factor EUT Test Mode WZ-AC1 Dick Shen BBHA 9120D_1167_1-18GHz OmniAccess Stellar (OAW-AP1521) Mode 1 Test Date Temp./Humidity Polarity Test Voltage 2024-10-27 26.1C/53.2% Vertical AC 120V/60Hz Frequency No Mark (MHz) Reading (dBV) C.F (dB/m) Measurement (dBV/m) 1 * 10538.700 30.32 14.89 45.21 2 10538.700 35.31 14.89 50.20 3 14594.900 25.30 15.69 40.99 4 14594.900 36.15 15.69 51.85 5 17996.600 20.56 22.59 43.15 6 17996.600 34.25 22.59 56.84 Notes: 1. " * ", means this data is the worst emission level. 2. C.F (dB/m) = Antenna Factor (dB/m) + Cable Loss (dB) - AMP (dB). 3. Measurement(dBV/m) = Reading(dBV) + C.F (dB/m). Margin (dB) -8.79 -23.80 -13.01 -22.15 -10.85 -17.16 Limit (dBV/m) 54.00 74.00 54.00 74.00 54.00 74.00 Detector Average Peak Average Peak Average Peak 33 of 73 Report No.: 2408RSU020-U8 Site Test Engineer Factor EUT Test Mode WZ-AC1 Ajin Fan BBHA 9170_549_18-40GHz OmniAccess Stellar (OAW-AP1521) Mode 1 Test Date Temp./Humidity Polarity Test Voltage 2024-11-07 26.1C/53.2% Horizontal AC 120V/60Hz Frequency No Mark (MHz) Reading (dBV) C.F (dB/m) Measurement (dBV/m) 1 20457.400 42.10 -9.13 32.97 2 20457.400 57.35 -9.13 48.22 3 26815.400 39.50 -5.48 34.02 4 26815.400 54.06 -5.48 48.59 5 * 39111.200 40.40 -0.90 39.50 6 39111.200 54.87 -0.90 53.97 Notes: 1. " * ", means this data is the worst emission level. 2. C.F (dB/m) = Antenna Factor (dB/m) + Cable Loss (dB) - AMP (dB). 3. Measurement(dBV/m) = Reading(dBV) + C.F (dB/m). Margin (dB) -21.03 -25.78 -19.98 -25.41 -14.50 -20.03 Limit (dBV/m) 54.00 74.00 54.00 74.00 54.00 74.00 Detector Average Peak Average Peak Average Peak 34 of 73 Report No.: 2408RSU020-U8 Site Test Engineer Factor EUT Test Mode WZ-AC1 Ajin Fan BBHA 9170_549_18-40GHz OmniAccess Stellar (OAW-AP1521) Mode 1 Test Date Temp./Humidity Polarity Test Voltage 2024-11-07 26.1C/53.2% Vertical AC 120V/60Hz Frequency No Mark (MHz) Reading (dBV) C.F (dB/m) Measurement (dBV/m) 1 22991.800 39.60 -6.55 33.05 2 22991.800 54.34 -6.55 47.79 3 29583.000 41.10 -6.03 35.07 4 29583.000 56.13 -6.03 50.10 5 * 39859.200 40.80 -0.06 40.74 6 39859.200 53.76 -0.06 53.70 Notes: 1. " * ", means this data is the worst emission level. 2. C.F (dB/m) = Antenna Factor (dB/m) + Cable Loss (dB) - AMP (dB). 3. Measurement(dBV/m) = Reading(dBV) + C.F (dB/m). Margin (dB) -20.95 -26.21 -18.93 -23.90 -13.26 -20.30 Limit (dBV/m) 54.00 74.00 54.00 74.00 54.00 74.00 Detector Average Peak Average Peak Average Peak 35 of 73 Report No.: 2408RSU020-U8 Site Test Engineer Factor EUT Test Mode WZ-AC2 Ajin Fan VULB 9162_30-7000MHz OmniAccess Stellar (OAW-AP1521) Mode 2 Test Date Temp./Humidity Polarity Test Voltage 2024-11-05 25.8C/25.8% Horizontal By POE Frequency No Mark (MHz) Reading (dBV) C.F (dB/m) Measurement (dBV/m) 1 48.236 0.25 20.47 20.72 2 202.236 12.25 18.86 31.11 3 * 250.000 21.09 20.20 41.29 4 343.116 14.02 22.73 36.75 5 442.541 9.60 24.16 33.76 6 799.986 8.77 30.69 39.46 Notes: 1. " * ", means this data is the worst emission level. 2. C.F (dB/m) = Antenna Factor (dB/m) + Cable Loss (dB). 3. Measurement(dBV/m) = Reading(dBV) + C.F (dB/m). Margin (dB) -19.28 -12.39 -4.71 -9.25 -12.24 -6.54 Limit (dBV/m) 40.00 43.50 46.00 46.00 46.00 46.00 Detector QP QP QP QP QP QP 36 of 73 Report No.: 2408RSU020-U8 Site Test Engineer Factor EUT Test Mode WZ-AC2 Ajin Fan VULB 9162_30-7000MHz OmniAccess Stellar (OAW-AP1521) Mode 2 Test Date Temp./Humidity Polarity Test Voltage 2024-11-05 25.8C/25.8% Vertical By POE Frequency No Mark (MHz) Reading (dBV) C.F (dB/m) Measurement (dBV/m) 1 * 34.539 19.45 17.44 36.89 2 58.033 12.11 19.76 31.87 3 200.526 10.31 18.98 29.29 4 346.996 14.70 22.95 37.65 5 553.606 9.58 26.50 36.08 6 799.986 6.47 30.69 37.16 Notes: 1. " * ", means this data is the worst emission level. 2. C.F (dB/m) = Antenna Factor (dB/m) + Cable Loss (dB). 3. Measurement(dBV/m) = Reading(dBV) + C.F (dB/m). Margin (dB) -3.11 -8.13 -14.21 -8.35 -9.92 -8.84 Limit (dBV/m) 40.00 40.00 43.50 46.00 46.00 46.00 Detector QP QP QP QP QP QP 37 of 73 Report No.: 2408RSU020-U8 Site Test Engineer Factor EUT Test Mode WZ-AC2 Ajin Fan BBHA 9120D_1457_1-18GHz OmniAccess Stellar (OAW-AP1521) Mode 2 Test Date Temp./Humidity Polarity Test Voltage 2024-11-05 25.8C/25.8% Horizontal By POE Frequency No Mark (MHz) Reading (dBV) C.F (dB/m) Measurement (dBV/m) 1 11572.300 18.89 17.06 35.95 2 11572.300 33.87 17.06 50.93 3 14929.800 19.80 19.19 38.99 4 14929.800 33.82 19.19 53.01 5 * 17962.600 19.35 27.95 47.30 6 17962.600 35.17 27.95 63.12 Notes: 1. " * ", means this data is the worst emission level. 2. C.F (dB/m) = Antenna Factor (dB/m) + Cable Loss (dB) - AMP (dB). 3. Measurement(dBV/m) = Reading(dBV) + C.F (dB/m). Margin (dB) -18.05 -23.07 -15.01 -20.99 -6.70 -10.88 Limit (dBV/m) 54.00 74.00 54.00 74.00 54.00 74.00 Detector Average Peak Average Peak Average Peak 38 of 73 Report No.: 2408RSU020-U8 Site Test Engineer Factor EUT Test Mode WZ-AC2 Ajin Fan BBHA 9120D_1457_1-18GHz OmniAccess Stellar (OAW-AP1521) Mode 2 Test Date Temp./Humidity Polarity Test Voltage 2024-11-05 25.8C/25.8% Vertical By POE Frequency No Mark (MHz) Reading (dBV) C.F (dB/m) Measurement (dBV/m) 1 9647.900 23.98 12.77 36.75 2 9647.900 37.57 12.77 50.33 3 14521.800 19.20 19.00 38.20 4 14521.800 34.27 19.00 53.27 5 * 17986.400 19.56 28.56 48.12 6 17986.400 34.01 28.56 62.58 Notes: 1. " * ", means this data is the worst emission level. 2. C.F (dB/m) = Antenna Factor (dB/m) + Cable Loss (dB) - AMP (dB). 3. Measurement(dBV/m) = Reading(dBV) + C.F (dB/m). Margin (dB) -17.25 -23.67 -15.80 -20.73 -5.88 -11.42 Limit (dBV/m) 54.00 74.00 54.00 74.00 54.00 74.00 Detector Average Peak Average Peak Average Peak 39 of 73 Report No.: 2408RSU020-U8 Site Test Engineer Factor EUT Test Mode WZ-AC1 Ajin Fan BBHA 9170_549_18-40GHz OmniAccess Stellar (OAW-AP1521) Mode 2 Test Date Temp./Humidity Polarity Test Voltage 2024-11-07 26.1C/53.2% Horizontal By POE Frequency No Mark (MHz) Reading (dBV) C.F (dB/m) Measurement (dBV/m) 1 21535.400 39.00 -8.22 30.78 2 21535.400 55.67 -8.22 47.44 3 26971.600 41.30 -6.22 35.08 4 26971.600 55.47 -6.22 49.25 5 * 39419.200 38.80 -0.31 38.49 6 39419.200 54.66 -0.31 54.35 Notes: 1. " * ", means this data is the worst emission level. 2. C.F (dB/m) = Antenna Factor (dB/m) + Cable Loss (dB) - AMP (dB). 3. Measurement(dBV/m) = Reading(dBV) + C.F (dB/m). Margin (dB) -23.22 -26.56 -18.92 -24.75 -15.51 -19.65 Limit (dBV/m) 54.00 74.00 54.00 74.00 54.00 74.00 Detector Average Peak Average Peak Average Peak 40 of 73 Report No.: 2408RSU020-U8 Site Test Engineer Factor EUT Test Mode WZ-AC1 Ajin Fan BBHA 9170_549_18-40GHz OmniAccess Stellar (OAW-AP1521) Mode 2 Test Date Temp./Humidity Polarity Test Voltage 2024-11-07 26.1C/53.2% Vertical By POE Frequency No Mark (MHz) Reading (dBV) C.F (dB/m) Measurement (dBV/m) 1 23154.600 39.20 -6.65 32.55 2 23154.600 54.49 -6.65 47.84 3 26800.000 39.70 -5.35 34.35 4 26800.000 54.04 -5.35 48.69 5 * 39282.800 38.60 -0.51 38.09 6 39282.800 53.94 -0.51 53.42 Notes: 1. " * ", means this data is the worst emission level. 2. C.F (dB/m) = Antenna Factor (dB/m) + Cable Loss (dB) - AMP (dB). 3. Measurement(dBV/m) = Reading(dBV) + C.F (dB/m). Margin (dB) -21.45 -26.16 -19.65 -25.31 -15.91 -20.58 Limit (dBV/m) 54.00 74.00 54.00 74.00 54.00 74.00 Detector Average Peak Average Peak Average Peak 41 of 73 Site Temperature Limit Factor EUT Test Mode Report No.: 2408RSU020-U8 SIP-AC3 19.3C FCC_Part 15.209_RSE(3m)_QP VULB 9168_00997_25-2000MHz OmniAccess Stellar (OAW-AP1521) Mode 3 Test Date Humidity Test Engineer Polarity Test Voltage 2024-12-18 35.2% Fusco Pan Horizontal AC 120V/60Hz Frequency No Mark (MHz) Reading (dBV) C.F (dB/m) Measurement (dBV/m) 1 150.116 6.00 18.44 24.44 2 172.236 12.50 17.65 30.15 3 * 250.038 18.80 17.02 35.82 4 300.052 12.40 18.70 31.10 5 376.995 11.40 20.57 31.97 6 922.192 -9.80 30.03 20.23 Notes: 1. " * ", means this data is the worst emission level. 2. C.F (dB/m) = Antenna Factor (dB/m) + Cable Loss (dB). 3. Measurement (dBV/m) = Reading (dBV) + C.F (dB/m). Margin (dB) -19.06 -13.35 -10.18 -14.90 -14.03 -25.77 Limit (dBV/m) 43.50 43.50 46.00 46.00 46.00 46.00 Detector QP QP QP QP QP QP 42 of 73 Site Temperature Limit Factor EUT Test Mode Report No.: 2408RSU020-U8 SIP-AC3 19.3C FCC_Part 15.209_RSE(3m)_QP VULB 9168_00997_25-2000MHz OmniAccess Stellar (OAW-AP1521) Mode 3 Test Date Humidity Test Engineer Polarity Test Voltage 2024-12-18 35.2% Fusco Pan Vertical AC 120V/60Hz Frequency No Mark (MHz) Reading (dBV) C.F (dB/m) Measurement (dBV/m) 1 38.292 11.20 17.83 29.03 2 48.860 7.60 18.65 26.25 3 58.264 10.40 18.25 28.65 4 82.013 16.30 13.74 30.04 5 * 177.323 20.40 17.12 37.52 6 250.038 20.80 17.02 37.82 Notes: 1. " * ", means this data is the worst emission level. 2. C.F (dB/m) = Antenna Factor (dB/m) + Cable Loss (dB). 3. Measurement (dBV/m) = Reading (dBV) + C.F (dB/m). Margin (dB) -10.97 -13.75 -11.35 -9.96 -5.98 -8.18 Limit (dBV/m) 40.00 40.00 40.00 40.00 43.50 46.00 Detector QP QP QP QP QP QP 43 of 73 Report No.: 2408RSU020-U8 Site Test Engineer Factor EUT Test Mode SIP-AC3 Mero Zhou HF907_102861_1-18GHz OmniAccess Stellar (OAW-AP1521) Mode 3 Test Date Temp./Humidity Polarity Test Voltage 2024-11-07 21.1C/51.5% Horizontal AC 120V/60Hz Frequency No Mark (MHz) Reading (dBV) C.F (dB/m) Measurement (dBV/m) Margin (dB) 1 9647.900 54.31 -1.55 52.76 -21.24 2 * 9647.900 49.36 -1.55 47.81 -6.19 3 16109.600 47.06 5.67 52.73 -21.27 4 16109.600 34.37 5.67 40.04 -13.96 5 17532.500 45.60 8.81 54.40 -19.60 6 17532.500 31.69 8.81 40.50 -13.50 Notes: 1. " * ", means this data is the worst emission level. 2. C.F (dB/m) = Antenna Factor (dB/m) + Cable Loss (dB) - AMP (dB). 3. Measurement(dBV/m) = Reading(dBV) + C.F (dB/m). Limit (dBV/m) 74.00 54.00 74.00 54.00 74.00 54.00 Detector Peak Average Peak Average Peak Average 44 of 73 Report No.: 2408RSU020-U8 Site Test Engineer Factor EUT Test Mode SIP-AC3 Mero Zhou HF907_102861_1-18GHz OmniAccess Stellar (OAW-AP1521) Mode 3 Test Date Temp./Humidity Polarity Test Voltage 2024-11-07 21.1C/51.5% Vertical AC 120V/60Hz Frequency No Mark (MHz) Reading (dBV) C.F (dB/m) Measurement (dBV/m) Margin (dB) 1 9647.900 52.38 -1.55 50.83 -23.17 2 * 9647.900 47.51 -1.55 45.96 -8.04 3 14023.700 47.02 3.48 50.50 -23.50 4 14023.700 34.95 3.48 38.43 -15.57 5 17959.200 43.24 10.24 53.48 -20.52 6 17959.200 31.54 10.24 41.78 -12.22 Notes: 1. " * ", means this data is the worst emission level. 2. C.F (dB/m) = Antenna Factor (dB/m) + Cable Loss (dB) - AMP (dB). 3. Measurement(dBV/m) = Reading(dBV) + C.F (dB/m). Limit (dBV/m) 74.00 54.00 74.00 54.00 74.00 54.00 Detector Peak Average Peak Average Peak Average 45 of 73 Report No.: 2408RSU020-U8 Site Test Engineer Factor EUT Test Mode SIP-AC3 Mero Zhou BBHA 9170_00934_18-40GHz OmniAccess Stellar (OAW-AP1521) Mode 3 Test Date Temp./Humidity Polarity Test Voltage 2024-11-15 20.7C/62.4% Horizontal AC 120V/60Hz Frequency No Mark (MHz) Reading (dBV) C.F (dB/m) Measurement (dBV/m) Margin (dB) 1 31094.400 57.59 -9.10 48.49 -25.51 2 31094.400 45.75 -9.10 36.65 -17.35 3 37749.400 55.06 -2.78 52.27 -21.73 4 37749.400 42.64 -2.78 39.86 -14.14 5 39249.800 52.52 0.80 53.31 -20.69 6 * 39249.800 41.34 0.80 42.14 -11.86 Notes: 1. " * ", means this data is the worst emission level. 2. C.F (dB/m) = Antenna Factor (dB/m) + Cable Loss (dB) - AMP (dB). 3. Measurement(dBV/m) = Reading(dBV) + C.F (dB/m). Limit (dBV/m) 74.00 54.00 74.00 54.00 74.00 54.00 Detector Peak Average Peak Average Peak Average 46 of 73 Report No.: 2408RSU020-U8 Site Test Engineer Factor EUT Test Mode SIP-AC3 Mero Zhou BBHA 9170_00934_18-40GHz OmniAccess Stellar (OAW-AP1521) Mode 3 Test Date Temp./Humidity Polarity Test Voltage 2024-11-15 20.7C/62.4% Vertical AC 120V/60Hz Frequency No Mark (MHz) Reading (dBV) C.F (dB/m) Measurement (dBV/m) Margin (dB) 1 30498.200 57.70 -8.51 49.19 -24.81 2 30498.200 45.64 -8.51 37.13 -16.87 3 37734.000 53.68 -2.86 50.82 -23.18 4 37734.000 42.69 -2.86 39.83 -14.17 5 39203.600 52.52 -0.07 52.45 -21.55 6 * 39203.600 41.62 -0.07 41.55 -12.45 Notes: 1. " * ", means this data is the worst emission level. 2. C.F (dB/m) = Antenna Factor (dB/m) + Cable Loss (dB) - AMP (dB). 3. Measurement(dBV/m) = Reading(dBV) + C.F (dB/m). Limit (dBV/m) 74.00 54.00 74.00 54.00 74.00 54.00 Detector Peak Average Peak Average Peak Average 47 of 73 Site Temperature Limit Factor EUT Test Mode Report No.: 2408RSU020-U8 SIP-AC3 19.3C FCC_Part 15.209_RSE(3m)_QP VULB 9168_00997_25-2000MHz OmniAccess Stellar (OAW-AP1521) Mode 4 Test Date Humidity Test Engineer Polarity Test Voltage 2024-12-18 35.2% Fusco Pan Horizontal AC 120V/60Hz Frequency No Mark (MHz) Reading (dBV) C.F (dB/m) Measurement (dBV/m) 1 165.023 11.63 18.11 29.74 2 199.986 11.38 15.11 26.49 3 * 250.038 20.30 17.02 37.32 4 300.052 11.40 18.70 30.09 5 379.116 9.24 20.61 29.84 6 947.763 -9.40 30.24 20.84 Notes: 1. " * ", means this data is the worst emission level. 2. C.F (dB/m) = Antenna Factor (dB/m) + Cable Loss (dB). 3. Measurement (dBV/m) = Reading (dBV) + C.F (dB/m). Margin (dB) -13.76 -17.01 -8.68 -15.91 -16.16 -25.16 Limit (dBV/m) 43.50 43.50 46.00 46.00 46.00 46.00 Detector QP QP QP QP QP QP 48 of 73 Site Temperature Limit Factor EUT Test Mode Report No.: 2408RSU020-U8 SIP-AC3 19.3C FCC_Part 15.209_RSE(3m)_QP VULB 9168_00997_25-2000MHz OmniAccess Stellar (OAW-AP1521) Mode 4 Test Date Humidity Test Engineer Polarity Test Voltage 2024-12-18 35.2% Fusco Pan Vertical AC 120V/60Hz Frequency No Mark (MHz) Reading (dBV) C.F (dB/m) Measurement (dBV/m) 1 38.012 10.43 17.80 28.23 2 58.469 10.23 18.23 28.46 3 80.137 15.39 14.17 29.56 4 * 176.640 18.20 17.19 35.39 5 250.038 19.03 17.02 36.06 6 378.584 9.13 20.60 29.73 Notes: 1. " * ", means this data is the worst emission level. 2. C.F (dB/m) = Antenna Factor (dB/m) + Cable Loss (dB). 3. Measurement (dBV/m) = Reading (dBV) + C.F (dB/m). Margin (dB) -11.77 -11.54 -10.44 -8.11 -9.94 -16.27 Limit (dBV/m) 40.00 40.00 40.00 43.50 46.00 46.00 Detector QP QP QP QP QP QP 49 of 73 Report No.: 2408RSU020-U8 Site Test Engineer Factor EUT Test Mode SIP-AC3 Mero Zhou HF907_102861_1-18GHz OmniAccess Stellar (OAW-AP1521) Mode 4 Test Date Temp./Humidity Polarity Test Voltage 2024-11-07 21.1C/51.5% Horizontal AC 120V/60Hz Frequency No Mark (MHz) Reading (dBV) C.F (dB/m) Measurement (dBV/m) Margin (dB) 1 9647.900 53.48 -1.55 51.93 -22.07 2 * 9647.900 48.49 -1.55 46.94 -7.06 3 14144.400 47.14 3.20 50.35 -23.65 4 14144.400 34.68 3.20 37.88 -16.12 5 17467.900 45.88 8.42 54.31 -19.69 6 17467.900 31.75 8.42 40.17 -13.83 Notes: 1. " * ", means this data is the worst emission level. 2. C.F (dB/m) = Antenna Factor (dB/m) + Cable Loss (dB) - AMP (dB). 3. Measurement(dBV/m) = Reading(dBV) + C.F (dB/m). Limit (dBV/m) 74.00 54.00 74.00 54.00 74.00 54.00 Detector Peak Average Peak Average Peak Average 50 of 73 Report No.: 2408RSU020-U8 Site Test Engineer Factor EUT Test Mode SIP-AC3 Mero Zhou HF907_102861_1-18GHz OmniAccess Stellar (OAW-AP1521) Mode 4 Test Date Temp./Humidity Polarity Test Voltage 2024-11-07 21.1C/51.5% Vertical AC 120V/60Hz Frequency No Mark (MHz) Reading (dBV) C.F (dB/m) Measurement (dBV/m) Margin (dB) 1 9647.900 53.08 -1.55 51.52 -22.48 2 * 9647.900 48.57 -1.55 47.02 -6.98 3 14090.000 46.88 2.66 49.54 -24.46 4 14090.000 34.69 2.66 37.35 -16.65 5 17714.400 45.48 8.19 53.67 -20.33 6 17714.400 31.68 8.19 39.87 -14.13 Notes: 1. " * ", means this data is the worst emission level. 2. C.F (dB/m) = Antenna Factor (dB/m) + Cable Loss (dB) - AMP (dB). 3. Measurement(dBV/m) = Reading(dBV) + C.F (dB/m). Limit (dBV/m) 74.00 54.00 74.00 54.00 74.00 54.00 Detector Peak Average Peak Average Peak Average 51 of 73 Report No.: 2408RSU020-U8 Site Test Engineer Factor EUT Test Mode SIP-AC3 Mero Zhou BBHA 9170_00934_18-40GHz OmniAccess Stellar (OAW-AP1521) Mode 4 Test Date Temp./Humidity Polarity Test Voltage 2024-11-15 20.7C/62.4% Horizontal AC 120V/60Hz Frequency No Mark (MHz) Reading (dBV) C.F (dB/m) Measurement (dBV/m) Margin (dB) 1 30500.400 57.67 -8.49 49.18 -24.82 2 30500.400 44.79 -8.49 36.30 -17.70 3 37764.800 54.57 -2.77 51.80 -22.20 4 37764.800 42.19 -2.77 39.42 -14.58 5 39274.000 53.17 -0.11 53.05 -20.95 6 * 39274.000 41.34 -0.11 41.23 -12.77 Notes: 1. " * ", means this data is the worst emission level. 2. C.F (dB/m) = Antenna Factor (dB/m) + Cable Loss (dB) - AMP (dB). 3. Measurement(dBV/m) = Reading(dBV) + C.F (dB/m). Limit (dBV/m) 74.00 54.00 74.00 54.00 74.00 54.00 Detector Peak Average Peak Average Peak Average 52 of 73 Report No.: 2408RSU020-U8 Site Test Engineer Factor EUT Test Mode SIP-AC3 Mero Zhou BBHA 9170_00934_18-40GHz OmniAccess Stellar (OAW-AP1521) Mode 4 Test Date Temp./Humidity Polarity Test Voltage 2024-11-15 20.7C/62.4% Vertical AC 120V/60Hz Frequency No Mark (MHz) Reading (dBV) C.F (dB/m) Measurement (dBV/m) Margin (dB) 1 30533.400 57.19 -8.69 48.50 -25.50 2 30533.400 44.69 -8.69 36.00 -18.00 3 35441.600 56.82 -6.79 50.02 -23.98 4 35441.600 42.86 -6.79 36.07 -17.93 5 38908.800 54.43 -0.91 53.52 -20.48 6 * 38908.800 41.75 -0.91 40.84 -13.16 Notes: 1. " * ", means this data is the worst emission level. 2. C.F (dB/m) = Antenna Factor (dB/m) + Cable Loss (dB) - AMP (dB). 3. Measurement(dBV/m) = Reading(dBV) + C.F (dB/m). Limit (dBV/m) 74.00 54.00 74.00 54.00 74.00 54.00 Detector Peak Average Peak Average Peak Average 53 of 73 Site Temperature Limit Factor EUT Test Mode Report No.: 2408RSU020-U8 SIP-AC3 19.3C FCC_Part 15.209_RSE(3m)_QP VULB 9168_00997_25-2000MHz OmniAccess Stellar (OAW-AP1521) Mode 5 Test Date Humidity Test Engineer Polarity Test Voltage 2024-12-18 35.2% Fusco Pan Horizontal AC 120V/60Hz Frequency No Mark (MHz) Reading (dBV) C.F (dB/m) Measurement (dBV/m) 1 164.330 12.28 18.13 30.41 2 199.986 12.46 15.11 27.57 3 * 250.038 19.30 17.02 36.32 4 300.052 11.04 18.70 29.74 5 378.186 9.49 20.59 30.08 6 750.108 -10.40 28.42 18.02 Notes: 1. " * ", means this data is the worst emission level. 2. C.F (dB/m) = Antenna Factor (dB/m) + Cable Loss (dB). 3. Measurement (dBV/m) = Reading (dBV) + C.F (dB/m). Margin (dB) -13.09 -15.93 -9.68 -16.26 -15.92 -27.98 Limit (dBV/m) 43.50 43.50 46.00 46.00 46.00 46.00 Detector QP QP QP QP QP QP 54 of 73 Site Temperature Limit Factor EUT Test Mode Report No.: 2408RSU020-U8 SIP-AC3 19.3C FCC_Part 15.209_RSE(3m)_QP VULB 9168_00997_25-2000MHz OmniAccess Stellar (OAW-AP1521) Mode 5 Test Date Humidity Test Engineer Polarity Test Voltage 2024-12-18 35.2% Fusco Pan Vertical AC 120V/60Hz Frequency No Mark (MHz) Reading (dBV) C.F (dB/m) Measurement (dBV/m) 1 37.998 11.45 17.80 29.25 2 58.551 11.31 18.22 29.53 3 80.277 17.63 14.14 31.77 4 * 173.387 19.06 17.54 36.60 5 250.038 18.99 17.02 36.01 6 395.825 11.79 20.83 32.62 Notes: 1. " * ", means this data is the worst emission level. 2. C.F (dB/m) = Antenna Factor (dB/m) + Cable Loss (dB). 3. Measurement (dBV/m) = Reading (dBV) + C.F (dB/m). Margin (dB) -10.75 -10.47 -8.23 -6.90 -9.99 -13.38 Limit (dBV/m) 40.00 40.00 40.00 43.50 46.00 46.00 Detector QP QP QP QP QP QP 55 of 73 Report No.: 2408RSU020-U8 Site Test Engineer Factor EUT Test Mode SIP-AC3 Mero Zhou HF907_102861_1-18GHz OmniAccess Stellar (OAW-AP1521) Mode 5 Test Date Temp./Humidity Polarity Test Voltage 2024-11-07 21.1C/51.5% Horizontal AC 120V/60Hz Frequency No Mark (MHz) Reading (dBV) C.F (dB/m) Measurement (dBV/m) Margin (dB) 1 9647.900 52.58 -1.55 51.03 -22.97 2 * 9647.900 47.64 -1.55 46.09 -7.91 3 14243.000 46.97 3.23 50.20 -23.80 4 14243.000 34.69 3.23 37.92 -16.08 5 17841.900 44.66 9.21 53.86 -20.14 6 17841.900 31.57 9.21 40.78 -13.22 Notes: 1. " * ", means this data is the worst emission level. 2. C.F (dB/m) = Antenna Factor (dB/m) + Cable Loss (dB) - AMP (dB). 3. Measurement(dBV/m) = Reading(dBV) + C.F (dB/m). Limit (dBV/m) 74.00 54.00 74.00 54.00 74.00 54.00 Detector Peak Average Peak Average Peak Average 56 of 73 Report No.: 2408RSU020-U8 Site Test Engineer Factor EUT Test Mode SIP-AC3 Mero Zhou HF907_102861_1-18GHz OmniAccess Stellar (OAW-AP1521) Mode 5 Test Date Temp./Humidity Polarity Test Voltage 2024-11-07 21.1C/51.5% Vertical AC 120V/60Hz Frequency No Mark (MHz) Reading (dBV) C.F (dB/m) Measurement (dBV/m) Margin (dB) 1 9647.900 51.49 -1.55 49.94 -24.06 2 * 9647.900 46.57 -1.55 45.02 -8.98 3 14314.400 46.74 2.86 49.60 -24.40 4 14314.400 34.71 2.86 37.57 -16.43 5 17556.300 45.52 8.40 53.91 -20.09 6 17556.300 31.49 8.40 39.89 -14.11 Notes: 1. " * ", means this data is the worst emission level. 2. C.F (dB/m) = Antenna Factor (dB/m) + Cable Loss (dB) - AMP (dB). 3. Measurement(dBV/m) = Reading(dBV) + C.F (dB/m). Limit (dBV/m) 74.00 54.00 74.00 54.00 74.00 54.00 Detector Peak Average Peak Average Peak Average 57 of 73 Report No.: 2408RSU020-U8 Site Test Engineer Factor EUT Test Mode SIP-AC3 Mero Zhou BBHA 9170_00934_18-40GHz OmniAccess Stellar (OAW-AP1521) Mode 5 Test Date Temp./Humidity Polarity Test Voltage 2024-11-15 20.7C/62.4% Horizontal AC 120V/60Hz Frequency No Mark (MHz) Reading (dBV) C.F (dB/m) Measurement (dBV/m) Margin (dB) 1 30639.000 56.85 -8.43 48.42 -25.58 2 30639.000 45.67 -8.43 37.24 -16.76 3 37382.000 55.07 -3.36 51.72 -22.28 4 37382.000 42.76 -3.36 39.40 -14.60 5 39252.000 52.91 0.93 53.84 -20.16 6 * 39252.000 41.28 0.93 42.21 -11.79 Notes: 1. " * ", means this data is the worst emission level. 2. C.F (dB/m) = Antenna Factor (dB/m) + Cable Loss (dB) - AMP (dB). 3. Measurement(dBV/m) = Reading(dBV) + C.F (dB/m). Limit (dBV/m) 74.00 54.00 74.00 54.00 74.00 54.00 Detector Peak Average Peak Average Peak Average 58 of 73 Report No.: 2408RSU020-U8 Site Test Engineer Factor EUT Test Mode SIP-AC3 Mero Zhou BBHA 9170_00934_18-40GHz OmniAccess Stellar (OAW-AP1521) Mode 5 Test Date Temp./Humidity Polarity Test Voltage 2024-11-15 20.7C/62.4% Vertical AC 120V/60Hz Frequency No Mark (MHz) Reading (dBV) C.F (dB/m) Measurement (dBV/m) Margin (dB) 1 35575.800 56.44 -6.21 50.23 -23.77 2 35575.800 44.05 -6.21 37.84 -16.16 3 37727.400 55.06 -3.02 52.04 -21.96 4 37727.400 42.39 -3.02 39.37 -14.63 5 38933.000 53.91 -0.93 52.98 -21.02 6 * 38933.000 41.46 -0.93 40.53 -13.47 Notes: 1. " * ", means this data is the worst emission level. 2. C.F (dB/m) = Antenna Factor (dB/m) + Cable Loss (dB) - AMP (dB). 3. Measurement(dBV/m) = Reading(dBV) + C.F (dB/m). Limit (dBV/m) 74.00 54.00 74.00 54.00 74.00 54.00 Detector Peak Average Peak Average Peak Average 59 of 73 Site Temperature Limit Factor EUT Test Mode Report No.: 2408RSU020-U8 SIP-AC3 19.3C FCC_Part 15.209_RSE(3m)_QP VULB 9168_00997_25-2000MHz OmniAccess Stellar (OAW-AP1521) Mode 6 Test Date Humidity Test Engineer Polarity Test Voltage 2024-12-18 35.2% Fusco Pan Horizontal AC 120V/60Hz Frequency No Mark (MHz) Reading (dBV) C.F (dB/m) Measurement (dBV/m) 1 68.896 3.50 16.54 20.04 2 164.446 10.80 18.13 28.93 3 199.986 12.80 15.11 27.91 4 * 250.038 18.30 17.02 35.32 5 299.946 12.90 18.69 31.59 6 395.132 10.36 20.82 31.18 Notes: 1. " * ", means this data is the worst emission level. 2. C.F (dB/m) = Antenna Factor (dB/m) + Cable Loss (dB). 3. Measurement (dBV/m) = Reading (dBV) + C.F (dB/m). Margin (dB) -19.96 -14.57 -15.59 -10.68 -14.41 -14.82 Limit (dBV/m) 40.00 43.50 43.50 46.00 46.00 46.00 Detector QP QP QP QP QP QP 60 of 73 Site Temperature Limit Factor EUT Test Mode Report No.: 2408RSU020-U8 SIP-AC3 19.3C FCC_Part 15.209_RSE(3m)_QP VULB 9168_00997_25-2000MHz OmniAccess Stellar (OAW-AP1521) Mode 6 Test Date Humidity Test Engineer Polarity Test Voltage 2024-12-18 35.2% Fusco Pan Vertical AC 120V/60Hz Frequency No Mark (MHz) Reading (dBV) C.F (dB/m) Measurement (dBV/m) 1 37.733 12.10 17.77 29.87 2 58.963 12.30 18.17 30.47 3 79.048 16.30 14.44 30.74 4 * 169.897 18.23 17.84 36.07 5 250.038 18.60 17.02 35.62 6 395.686 11.60 20.83 32.43 Notes: 1. " * ", means this data is the worst emission level. 2. C.F (dB/m) = Antenna Factor (dB/m) + Cable Loss (dB). 3. Measurement (dBV/m) = Reading (dBV) + C.F (dB/m). Margin (dB) -10.13 -9.53 -9.26 -7.43 -10.38 -13.57 Limit (dBV/m) 40.00 40.00 40.00 43.50 46.00 46.00 Detector QP QP QP QP QP QP 61 of 73 Report No.: 2408RSU020-U8 Site Test Engineer Factor EUT Test Mode SIP-AC3 Mero Zhou HF907_102861_1-18GHz OmniAccess Stellar (OAW-AP1521) Mode 6 Test Date Temp./Humidity Polarity Test Voltage 2024-11-07 21.1C/51.5% Horizontal AC 120V/60Hz Frequency Reading No Mark (MHz) (dBV) C.F (dB/m) Measurement Margin (dBV/m) (dB) 1 9647.900 53.21 -1.55 51.66 -22.34 2 * 9647.900 48.88 -1.55 47.33 -6.67 3 14127.400 48.11 3.37 51.48 -22.52 4 14127.400 34.64 3.37 38.01 -15.99 5 17585.200 46.19 8.15 54.34 -19.66 6 17585.200 31.59 8.15 39.74 -14.26 Notes: 1. " * ", means this data is the worst emission level. 2. C.F (dB/m) = Antenna Factor (dB/m) + Cable Loss (dB) - AMP (dB). 3. Measurement(dBV/m) = Reading(dBV) + C.F (dB/m). Limit (dBV/m) 74.00 54.00 74.00 54.00 74.00 54.00 Detector Peak Average Peak Average Peak Average 62 of 73 Report No.: 2408RSU020-U8 Site Test Engineer Factor EUT Test Mode SIP-AC3 Mero Zhou HF907_102861_1-18GHz OmniAccess Stellar (OAW-AP1521) Mode 6 Test Date Temp./Humidity Polarity Test Voltage 2024-11-07 21.1C/51.5% Vertical AC 120V/60Hz Frequency No Mark (MHz) Reading (dBV) C.F (dB/m) Measurement (dBV/m) Margin (dB) 1 9647.900 52.72 -1.55 51.17 -22.83 2 * 9647.900 48.76 -1.55 47.21 -6.79 3 14124.000 47.07 3.37 50.45 -23.55 4 14124.000 34.76 3.37 38.13 -15.87 5 17454.300 45.40 8.84 54.24 -19.76 6 17454.300 31.86 8.84 40.70 -13.30 Notes: 1. " * ", means this data is the worst emission level. 2. C.F (dB/m) = Antenna Factor (dB/m) + Cable Loss (dB) - AMP (dB). 3. Measurement(dBV/m) = Reading(dBV) + C.F (dB/m). Limit (dBV/m) 74.00 54.00 74.00 54.00 74.00 54.00 Detector Peak Average Peak Average Peak Average 63 of 73 Report No.: 2408RSU020-U8 Site Test Engineer Factor EUT Test Mode SIP-AC3 Mero Zhou BBHA 9170_00934_18-40GHz OmniAccess Stellar (OAW-AP1521) Mode 6 Test Date Temp./Humidity Polarity Test Voltage 2024-11-15 20.7C/62.4% Horizontal AC 120V/60Hz Frequency No Mark (MHz) Reading (dBV) C.F (dB/m) Measurement (dBV/m) Margin (dB) 1 30650.000 56.65 -8.32 48.33 -25.67 2 30650.000 45.69 -8.32 37.37 -16.63 3 37749.400 54.67 -2.78 51.89 -22.11 4 37749.400 42.71 -2.78 39.93 -14.07 5 39188.200 53.58 0.00 53.58 -20.42 6 * 39188.200 41.31 0.00 41.31 -12.69 Notes: 1. " * ", means this data is the worst emission level. 2. C.F (dB/m) = Antenna Factor (dB/m) + Cable Loss (dB) - AMP (dB). 3. Measurement(dBV/m) = Reading(dBV) + C.F (dB/m). Limit (dBV/m) 74.00 54.00 74.00 54.00 74.00 54.00 Detector Peak Average Peak Average Peak Average 64 of 73 Report No.: 2408RSU020-U8 Site Test Engineer Factor EUT Test Mode SIP-AC3 Mero Zhou BBHA 9170_00934_18-40GHz OmniAccess Stellar (OAW-AP1521) Mode 6 Test Date Temp./Humidity Polarity Test Voltage 2024-11-15 20.7C/62.4% Vertical AC 120V/60Hz Frequency No Mark (MHz) Reading (dBV) C.F (dB/m) Measurement (dBV/m) Margin (dB) 1 35562.600 56.87 -6.43 50.44 -23.56 2 35562.600 44.58 -6.43 38.15 -15.85 3 37778.000 54.54 -2.80 51.74 -22.26 4 37778.000 43.64 -2.80 40.84 -13.16 5 39254.200 53.03 0.82 53.86 -20.14 6 * 39254.200 40.38 0.82 41.20 -12.80 Notes: 1. " * ", means this data is the worst emission level. 2. C.F (dB/m) = Antenna Factor (dB/m) + Cable Loss (dB) - AMP (dB). 3. Measurement(dBV/m) = Reading(dBV) + C.F (dB/m). Limit (dBV/m) 74.00 54.00 74.00 54.00 74.00 54.00 Detector Peak Average Peak Average Peak Average 65 of 73 Site Temperature Limit Factor EUT Test Mode Report No.: 2408RSU020-U8 SIP-AC3 19.3C FCC_Part 15.209_RSE(3m)_QP VULB 9168_00997_25-2000MHz OmniAccess Stellar (OAW-AP1521) Mode 7 Test Date Humidity Test Engineer Polarity Test Voltage 2024-12-18 35.2% Fusco Pan Horizontal AC 120V/60Hz Frequency No Mark (MHz) Reading (dBV) C.F (dB/m) Measurement (dBV/m) 1 163.468 11.04 18.17 29.21 2 199.986 12.96 15.11 28.07 3 * 250.038 18.28 17.02 35.31 4 300.052 12.99 18.70 31.68 5 393.748 10.18 20.80 30.98 6 750.108 -9.99 28.42 18.43 Notes: 1. " * ", means this data is the worst emission level. 2. C.F (dB/m) = Antenna Factor (dB/m) + Cable Loss (dB). 3. Measurement (dBV/m) = Reading (dBV) + C.F (dB/m). Margin (dB) -14.29 -15.43 -10.69 -14.32 -15.02 -27.57 Limit (dBV/m) 43.50 43.50 46.00 46.00 46.00 46.00 Detector QP QP QP QP QP QP 66 of 73 Site Temperature Limit Factor EUT Test Mode Report No.: 2408RSU020-U8 SIP-AC3 19.3C FCC_Part 15.209_RSE(3m)_QP VULB 9168_00997_25-2000MHz OmniAccess Stellar (OAW-AP1521) Mode 7 Test Date Humidity Test Engineer Polarity Test Voltage 2024-12-18 35.2% Fusco Pan Vertical AC 120V/60Hz Frequency No Mark (MHz) Reading (dBV) C.F (dB/m) Measurement (dBV/m) 1 37.932 11.10 17.79 28.89 2 58.020 11.30 18.28 29.58 3 79.800 15.80 14.25 30.05 4 * 173.814 18.91 17.50 36.41 5 250.038 19.51 17.02 36.53 6 394.716 11.57 20.81 32.38 Notes: 1. " * ", means this data is the worst emission level. 2. C.F (dB/m) = Antenna Factor (dB/m) + Cable Loss (dB). 3. Measurement (dBV/m) = Reading (dBV) + C.F (dB/m). Margin (dB) -11.11 -10.42 -9.95 -7.09 -9.47 -13.62 Limit (dBV/m) 40.00 40.00 40.00 43.50 46.00 46.00 Detector QP QP QP QP QP QP 67 of 73 Report No.: 2408RSU020-U8 Site Test Engineer Factor EUT Test Mode SIP-AC3 Barry Wu HF907_102861_1-18GHz OmniAccess Stellar (OAW-AP1521) Mode 7 Test Date Temp./Humidity Polarity Test Voltage 2024-11-07 21.1C/51.5% Horizontal AC 120V/60Hz Frequency No Mark (MHz) Reading (dBV) C.F (dB/m) Measurement (dBV/m) Margin (dB) 1 9647.900 53.61 -1.55 52.05 -21.95 2 * 9647.900 50.38 -1.55 48.83 -5.17 3 14236.200 48.49 3.20 51.69 -22.31 4 14236.200 34.10 3.20 37.30 -16.70 5 17435.600 45.08 8.80 53.88 -20.12 6 17435.600 31.50 8.80 40.30 -13.70 Notes: 1. " * ", means this data is the worst emission level. 2. C.F (dB/m) = Antenna Factor (dB/m) + Cable Loss (dB) - AMP (dB). 3. Measurement(dBV/m) = Reading(dBV) + C.F (dB/m). Limit (dBV/m) 74.00 54.00 74.00 54.00 74.00 54.00 Detector Peak Average Peak Average Peak Average 68 of 73 Report No.: 2408RSU020-U8 Site Test Engineer Factor EUT Test Mode SIP-AC3 Barry Wu HF907_102861_1-18GHz OmniAccess Stellar (OAW-AP1521) Mode 7 Test Date Temp./Humidity Polarity Test Voltage 2024-11-07 21.1C/51.5% Vertical AC 120V/60Hz Frequency No Mark (MHz) Reading (dBV) C.F (dB/m) Measurement (dBV/m) Margin (dB) 1 9647.900 53.26 -1.55 51.71 -22.29 2 * 9647.900 49.70 -1.55 48.15 -5.85 3 14006.700 46.78 3.64 50.43 -23.57 4 14006.700 34.20 3.64 37.84 -16.16 5 17541.000 45.12 9.01 54.13 -19.87 6 17541.000 31.30 9.01 40.31 -13.69 Notes: 1. " * ", means this data is the worst emission level. 2. C.F (dB/m) = Antenna Factor (dB/m) + Cable Loss (dB) - AMP (dB). 3. Measurement(dBV/m) = Reading(dBV) + C.F (dB/m). Limit (dBV/m) 74.00 54.00 74.00 54.00 74.00 54.00 Detector Peak Average Peak Average Peak Average 69 of 73 Report No.: 2408RSU020-U8 Site Test Engineer Factor EUT Test Mode SIP-AC3 Mero Zhou BBHA 9170_00934_18-40GHz OmniAccess Stellar (OAW-AP1521) Mode 7 Test Date Temp./Humidity Polarity Test Voltage 2024-11-15 20.7C/62.4% Horizontal AC 120V/60Hz Frequency No Mark (MHz) Reading (dBV) C.F (dB/m) Measurement (dBV/m) Margin (dB) 1 30511.400 58.05 -8.36 49.69 -24.31 2 30511.400 45.33 -8.36 36.97 -17.03 3 37670.200 55.92 -3.66 52.26 -21.74 4 37670.200 42.03 -3.66 38.37 -15.63 5 39142.000 54.68 -1.09 53.59 -20.41 6 * 39142.000 41.57 -1.09 40.48 -13.52 Notes: 1. " * ", means this data is the worst emission level. 2. C.F (dB/m) = Antenna Factor (dB/m) + Cable Loss (dB) - AMP (dB). 3. Measurement(dBV/m) = Reading(dBV) + C.F (dB/m). Limit (dBV/m) 74.00 54.00 74.00 54.00 74.00 54.00 Detector Peak Average Peak Average Peak Average 70 of 73 Report No.: 2408RSU020-U8 Site Test Engineer Factor EUT Test Mode SIP-AC3 Mero Zhou BBHA 9170_00934_18-40GHz OmniAccess Stellar (OAW-AP1521) Mode 7 Test Date Temp./Humidity Polarity Test Voltage 2024-11-15 20.7C/62.4% Vertical AC 120V/60Hz Frequency No Mark (MHz) Reading (dBV) C.F (dB/m) Measurement (dBV/m) Margin (dB) 1 35362.400 57.59 -6.91 50.69 -23.31 2 35362.400 44.58 -6.91 37.67 -16.33 3 37362.200 56.08 -3.69 52.38 -21.62 4 37362.200 43.38 -3.69 39.69 -14.31 5 39258.600 52.99 0.62 53.60 -20.40 6 * 39258.600 40.47 0.62 41.09 -12.91 Notes: 1. " * ", means this data is the worst emission level. 2. C.F (dB/m) = Antenna Factor (dB/m) + Cable Loss (dB) - AMP (dB). 3. Measurement(dBV/m) = Reading(dBV) + C.F (dB/m). Limit (dBV/m) 74.00 54.00 74.00 54.00 74.00 54.00 Detector Peak Average Peak Average Peak Average 71 of 73 Appendix A - Test Setup Photograph Refer to "2408RSU020-UT" file. Report No.: 2408RSU020-U8 72 of 73 Appendix B - EUT Photograph Refer to "2408RSU020-UE" file. Report No.: 2408RSU020-U8 The End 73 of 73
Related FCC IDs:
- 2AI9TOAW-AP152X - ALE USA Inc. OmniAccess Stellar [OAW-AP152X] Microsoft Word 2021