2408RSU020-U8-FCC IC EMC Test Report

dell

Test Report JBP

ALE USA Inc. OAW-AP152X 2AI9TOAW-AP152X 2AI9TOAWAP152X oaw ap152x

PDF Viewing Options

Not Your Device? Search For Manuals or Datasheets below:


File Info : application/pdf, 73 Pages, 1.78MB

Document DEVICE REPORTGetApplicationAttachment.html?id=8009335
MRT Technology (Suzhou) Co., Ltd Phone: +86-512-66308358 Web: www.mrt-cert.com

Report No.: 2408RSU020-U8

Report Version:

V01

Issue Date: 2024-12-27

EMC MEASUREMENT REPORT

FCC ID:

2AI9TOAW-AP152X

Applicant:

ALE USA Inc.

Address:

2000 Corporate Center Drive Thousand Oaks, CA 91320

Product:

OmniAccess Stellar

Model No.:

OAW-AP1521

Brand Name:

Alcatel-Lucent Enterprise

FCC Rule Part(s): FCC Part 15 Subpart B

ISED Rule(s): Test Procedure:

ICES-003 Issue 7 (October 15, 2020) RSS-Gen Issue 5 ANSI C63.4 - 2014

Result:

Complies

Received Date: 2024-08-13

Test Date:

2024-10-27 ~ 2024-12-18

Reviewed By: Approved By:

Vincent Yu Robin Wu

The test results relate only to the samples tested.

This equipment has been shown to be capable of compliance with the applicable technical standards as

indicated in the measurement report and was tested in accordance with the measurement procedures specified

in ANSI C63.4-2014. Test results reported herein relate only to the item(s) tested.

The test report shall not be reproduced except in full without the written approval of MRT Technology (Suzhou)

Co., Ltd.

Template Version:1.6

1 of 73

Report No. 2408RSU020-U8

Version V01

Revision History
Description Initial Report

Report No.: 2408RSU020-U8

Issue Date 2024-12-27

Note Valid

2 of 73

Report No.: 2408RSU020-U8

Description

CONTENTS

Page

1. General Information ................................................................................................................................ 4

1.1. Applicant........................................................................................................................................ 4

1.2. Manufacturer ................................................................................................................................. 4

1.3. Testing Facility............................................................................................................................... 4

1.4. Product Information ....................................................................................................................... 5

2. Test Configuration .................................................................................................................................. 6

2.1. Test Mode ..................................................................................................................................... 6 2.2. Configuration of Tested System.................................................................................................... 6 2.3. EMI Suppression Device(s)/Modifications .................................................................................... 8

3. Measuring Instrument ............................................................................................................................ 9

4. Decision Rules and Measurement Uncertainty...................................................................................11

4.1. Decision Rules .............................................................................................................................11

4.2. Measurement Uncertainty ............................................................................................................11

5. Test Result ............................................................................................................................................. 12

5.1. Summary ..................................................................................................................................... 12

5.2. Conducted Emission ................................................................................................................... 13

5.2.1. Test Limit ..................................................................................................................................... 13

5.2.2. Test Setup ................................................................................................................................... 13

5.2.3. Test Result................................................................................................................................... 14

5.3. Radiated Emission ...................................................................................................................... 28

5.3.1. Test Limit ..................................................................................................................................... 28

5.3.2. Test Setup ................................................................................................................................... 29 5.3.3. Test Result................................................................................................................................... 30

Appendix A - Test Setup Photograph .......................................................................................................... 30

Appendix B - EUT Photograph ..................................................................................................................... 73

3 of 73

1. General Information
1.1. Applicant ALE USA Inc. 2000 Corporate Center Drive Thousand Oaks, CA 91320

Report No.: 2408RSU020-U8

1.2. Manufacturer ALE USA Inc. 2000 Corporate Center Drive Thousand Oaks, CA 91320

1.3. Testing Facility

Test Site ­ MRT Suzhou Laboratory

Laboratory Location (Suzhou - Wuzhong)

D8 Building, No.2 Tian'edang Rd., Wuzhong Economic Development Zone, Suzhou, China

Laboratory Location (Suzhou - SIP)

4b Building, Liando U Valley, No.200 Xingpu Rd., Shengpu Town, Suzhou Industrial Park, China

Laboratory Location (Suzhou - Wujiang)

Building 1, No.1 Xingdong Road, Wujiang, Suzhou, Jiangsu, People's Republic of China

Laboratory Accreditations

A2LA: 3628.01

CNAS: L10551

FCC: CN1166

ISED: CN0001

VCCI:

R-20025 R-20141

G-20034 G-20134

C-20020 C-20103

T-20020 T-20104

Test Site ­ MRT Shenzhen Laboratory

Laboratory Location (Shenzhen)

1G, Building A, Junxiangda Building, Zhongshanyuan Road West, Nanshan District, Shenzhen, China

Laboratory Accreditations

A2LA: 3628.02

CNAS: L10551

FCC: CN1284

ISED: CN0105

Test Site ­ MRT Taiwan Laboratory

Laboratory Location (Taiwan)

No. 38, Fuxing 2nd Rd., Guishan Dist., Taoyuan City 333, Taiwan (R.O.C.)

Laboratory Accreditations

TAF: 3261

FCC: 291082, TW3261

ISED: TW3261

4 of 73

Report No.: 2408RSU020-U8

1.4. Product Information

Product Name

OmniAccess Stellar

Model No.

OAW-AP1521

20240819Sample#17 (Mode 1)

EUT Identification No. 20241104Sample#02 (Mode 2)

20240819Sample#16 & 20240819Sample#17 (Mode 3 ~ 7)

Wi-Fi Specification

802.11a/b/g/n/ac/ax/be

Zigbee Specification

802.15.4

Bluetooth Specification V5.1 Single Mode

Power Type

AC/DC Adapter Input or PoE Input

Operating Environment Indoor Use

Accessories

AC/DC Adapter

Model: ADP-50GR B

Input: 100-240V ~ 50/60Hz, 1.3A

Output: 48.0V, 1.042A, 50.1W MAX

PoE Injector

Model: POE60U-1BT-X (ALE P/N: POE60U-1BT-X-R)

Input: 100-240V ~ 1.5A, 50/60Hz

Output: 56.0V, 0.535A, 30W

PIN 3, 6+

PIN 1, 2 Return

Output: 56.0V, 0.535A, 30W

PIN 4, 5+

PIN 7, 8 Return

Notes:

1. The information of EUT was provided by the manufacturer, and the accuracy of the information shall be

the responsibility of the manufacturer.

2. AC/DC Adapter and PoE Injector are not sold with product.

5 of 73

Report No.: 2408RSU020-U8
2. Test Configuration
2.1. Test Mode Mode 1: OAW-AP1521 powered by adapter + Ethernet port connect to computer via LAN cable + Connect to mobile phone via 2.4G/5G/6G Wi-Fi + Connect to mobile phone via BLE + Plug USB flash and make it reading/writing. Mode 2: OAW-AP1521 powered by PoE and connect to notebook via LAN cable + Connect to mobile phone via 2.4G/5G/6G Wi-Fi + Connect to signal generator via Zigbee + Plug USB flash and make it reading/writing. Mode 3: OAW-AP1521 powered by adapter Ethernet port connect to computer via LAN cable + Plug USB flash + Make EUT in 2.4GHz Wi-Fi receiving mode. Mode 4: OAW-AP1521 powered by adapter Ethernet port connect to computer via LAN cable + Plug USB flash + Make EUT in 5GHz Wi-Fi receiving mode. Mode 5: OAW-AP1521 powered by adapter Ethernet port connect to computer via LAN cable + Plug USB flash + Make EUT in 6GHz Wi-Fi receiving mode. Mode 6: OAW-AP1521 powered by adapter Ethernet port connect to computer via LAN cable + Plug USB flash + Make EUT in BLE receiving mode. Mode 7: OAW-AP1521 powered by adapter Ethernet port connect to computer via LAN cable + Plug USB flash + Make EUT in Zigbee receiving mode.
2.2. Configuration of Tested System The measurement procedures and appropriate EUT setup described in the ANSI C63.4-2014 was used in the measurement. Mode 1
6 of 73

Mode 2

Report No.: 2408RSU020-U8

Mode 3 ~ 7

No. Cable Type A DC Power Cable B LAN Cable C LAN Cable No. Product 1 USB Flash 2 Mobile Phone 3 Mobile Phone 4 Mobile Phone 5 Mobile Phone

Cable Spec. Shielding Non-Shielding, Cat 6 Non-Shielding, Cat 5e Manufacturer Samsung Apple Apple VIVO OPPO
7 of 73

Length 1.6m >10.0m >10.0m Model No. 64G iPhone 6S iPhone 13 X90 Pro X9009

6 Computer 7 Signal Generator 8 Notebook

HP R&S Lenovo

Report No.: 2408RSU020-U8
ZHAN 66 SMU200A Thinkbook16

2.3. EMI Suppression Device(s)/Modifications No EMI suppression device(s) were added and/or no modifications were made during testing.

8 of 73

Report No.: 2408RSU020-U8

3. Measuring Instrument

Instrument Name EMI Test Receiver Horn Antenna Horn Antenna Preamplifier TRILOG Antenna Anechoic Chamber Signal Analyzer Thermohygrometer Preamplifier TRILOG Antenna EMI Test Receiver Horn Antenna Preamplifier Anechoic Chamber Thermohygrometer Two-Line V-Network Shielding Room Thermohygrometer EMI Test Receiver Four-Line V-Network Preamplifier Horn Antenna Thermohygrometer Preamplifier TRILOG Antenna Anechoic Chamber Preamplifier Horn Antenna Signal Analyzer Signal Analyzer Two-Line V-Network EMI Test Receiver Thermohygrometer Shielding Room Four-Line V-Network

Manufacturer R&S Schwarzbeck Schwarzbeck Agilent Schwarzbeck TDK Keysight testo EMCI Schwarzbeck Agilent Schwarzbeck Schwarzbeck RIKEN testo R&S MIX-BEP testo R&S R&S Schwarzbeck R&S testo EMCI Schwarzbeck RIKEN EMCI Schwarzbeck Keysight Keysight R&S R&S testo MIX-BEP R&S

Model No. ESR7 BBHA 9120D BBHA 9170 83017A VULB 9168 WZ-AC1 N9010B 608-H1 EMC184045SE VULB 9162 N9038A BBHA 9120D BBV 9718 WZ-AC2 608-H1 ENV216 WZ-SR2 608-H1 ESR3 ENV432 BBV 9721 HF907 608-H1 EMC012645SE VULB 9168 SIP-AC3 EMC184045SE BBHA 9170 N9010B N9020B ENV216 ESR3 608-H1 SIP-SR2 ENV432

Asset No. MRTSUE06001 MRTSUE06023 MRTSUE06024 MRTSUE06076 MRTSUE06172 MRTSUE06212 MRTSUE06607 MRTSUE11039 MRTSUE06640 MRTSUE06022 MRTSUE06125 MRTSUE06171 MRTSUE06176 MRTSUE06213 MRTSUE11263 MRTSUE06002 MRTSUE06215 MRTSUE06404 MRTSUE06909 MRTSUE06615 MRTSUE06121 MRTSUE06611 MRTSUE06619 MRTSUE06642 MRTSUE06646 MRTSUE06782 MRTSUE06602 MRTSUE06599 MRTSUE06603 MRTSUE06604 MRTSUE06003 MRTSUE06612 MRTSUE06621 MRTSUE06949 MRTSUE06614

9 of 73

Cali. Interval 1 year 1 year 1 year 1 year 1 year 1 year 1 year 1 year 1 year 1 year 1 year 1 year 1 year 1 year 1 year 1 year 5 years 1 year 1 year 1 year 1 year 1 year 1 year 1 year 1 year 1 year 1 year 1 year 1 year 1 year 1 year 1 year 1 year 5 years 1 year

Cal. Due Date Test Site

2025-12-05

WZ-AC1

2025-07-26

WZ-AC1

2025-09-23

WZ-AC1

2025-11-08

WZ-AC1

2025-05-15

WZ-AC1

2025-04-19

WZ-AC1

2025-10-13

WZ-AC1

2025-10-16

WZ-AC1

2025-01-11

WZ-AC1

2025-04-17

WZ-AC2

2025-05-08

WZ-AC2

2025-09-23

WZ-AC2

2025-05-06

WZ-AC2

2025-04-18

WZ-AC2

2025-10-16

WZ-AC2

2025-05-08

WZ-SR2

2026-12-20

WZ-SR2

2025-05-12

WZ-SR2

2025-09-05

WZ-SR2

2025-09-05

WZ-SR2

2025-06-06

SIP-AC3

2025-07-07

SIP-AC3

2025-10-16

SIP-AC3

2025-01-11

SIP-AC3

2025-07-29

SIP-AC3

2025-12-20

SIP-AC3

2025-10-08

SIP-AC3

2025-09-08

SIP-AC3

2025-09-05

SIP-AC3

2025-02-03

SIP-AC3

2025-05-08

SIP-SR2

2025-05-08

SIP-SR2

2025-10-29

SIP-SR2

2029-10-13

SIP-SR2

2025-10-13

SIP-SR2

Software e3 Controller_MF 7802 Controller_MF 7802 Controller_MF 7802BS

Version 230711 2.03C 1.02 1.02

Report No.: 2408RSU020-U8
Function RE & CE RE Antenna & turntable RE Antenna & Turntable RE Antenna & Turntable

10 of 73

Report No.: 2408RSU020-U8
4. Decision Rules and Measurement Uncertainty
4.1. Decision Rules The Decision Rule is based on Simple Acceptance in accordance with ISO Guide 98-4: 2012 Clause 8.2. (Measurement uncertainty is not taken into account when stating conformity with a specified requirement.)
4.2. Measurement Uncertainty Where relevant, the following test uncertainty levels have been estimated for tests performed on the EUT as specified in CISPR 16-4-2. This uncertainty represents an expanded uncertainty expressed at approximately the 95% confidence level using a coverage factor of k = 2. Conducted Emission Measurement
The maximum measurement uncertainty is evaluated as: 9kHz~150kHz: 3.02dB 150kHz~30MHz: 2.56dB Radiated Emission Measurement The maximum measurement uncertainty is evaluated as: Horizontal: 30MHz~200MHz: 3.46dB
200MHz~1GHz: 3.78dB 1GHz~40GHz: 4.97dB Vertical: 30MHz~200MHz: 4.07dB 200MHz~1GHz: 5.28dB 1GHz~40GHz: 4.78dB
11 of 73

5. Test Result
5.1. Summary FCC Part Section(s) 15.107
15.109

ISED Section(s)
ICES-003 - 3.2.1 RSS-Gen - 7.2 ICES-003 - 3.2.2 RSS-Gen - 7.3

Report No.: 2408RSU020-U8

Test Description Conducted Emission Radiated Emission

Result Pass Pass

12 of 73

Report No.: 2408RSU020-U8

5.2. Conducted Emission

5.2.1. Test Limit
Frequency Range (MHz)
0.15 ~ 0.5 0.5 ~ 5 5 ~ 30

FCC Part 15.107 / ICES-003 Conducted Emission Limits

Class A Limits

Class B Limits

QP dB(V)
79

AV dB(V)
66

QP dB(V)
66 to 56

AV dB(V)
56 to 46

73

60

56

46

73

60

60

50

Frequency Range (MHz)
0.15 ~ 0.5 0.5 ~ 5 5 ~ 30

RSS-Gen Receiver Conducted Emission Limits QP
dB(V) 66 to 56
56 60

AV dB(V) 56 to 46
46 50

5.2.2. Test Setup

13 of 73

Report No.: 2408RSU020-U8

5.2.3. Test Result

Site Test Engineer Factor EUT Test Mode

WZ-SR2 Linda Wei ENV216_101683_L1_Filter Off_C OmniAccess Stellar (OAW-AP1521) Mode 1, Power Port

Test Date Temp./Humidity Polarity Test Voltage

2024-10-28 22.8C/66.0% Line AC 120V/60Hz

Frequency No Mark
(MHz)

Reading (dBV)

C.F

Measurement

(dB)

(dBV)

1

0.150

26.70

9.82

36.52

2 *

0.150

45.30

9.82

55.12

3

0.202

14.80

9.82

24.62

4

0.202

35.70

9.82

45.52

5

0.384

20.80

9.88

30.68

6

0.384

29.60

9.88

39.48

7

1.370

9.60

10.12

19.72

8

1.370

17.30

10.12

27.42

9

7.200

13.90

10.26

24.16

10

7.200

20.00

10.26

30.26

11

13.850

16.40

10.50

26.90

12

13.850

21.80

10.50

32.30

Notes: 1. " * ", means this data is the worst emission level. 2. C.F (dB) = LISN Factor (dB) + Cable Loss (dB). 3. Measurement (dBV) = Reading (dBV) + C.F (dB).
14 of 73

Margin (dB) -19.48 -10.88 -28.91 -18.01 -17.51 -18.71 -26.28 -28.58 -25.84 -29.74 -23.10 -27.70

Limit (dBV) 56.00 66.00 53.53 63.53 48.19 58.19 46.00 56.00 50.00 60.00 50.00 60.00

Detector
Average QP
Average QP
Average QP
Average QP
Average QP
Average QP

Report No.: 2408RSU020-U8

Site Test Engineer Factor EUT Test Mode

WZ-SR2 Linda Wei ENV216_101683_N_Filter Off_C OmniAccess Stellar (OAW-AP1521) Mode 1, Power Port

Test Date Temp./Humidity Polarity Test Voltage

2024-10-28 22.8C/66.0% Neutral AC 120V/60Hz

Frequency No Mark
(MHz)

Reading (dBV)

C.F

Measurement

(dB)

(dBV)

1

0.152

27.00

10.13

37.13

2 *

0.152

44.10

10.13

54.23

3

0.165

21.50

10.12

31.62

4

0.165

41.60

10.12

51.72

5

0.383

21.20

10.13

31.33

6

0.383

29.60

10.13

39.73

7

1.200

10.30

10.38

20.68

8

1.200

18.50

10.38

28.88

9

13.860

15.00

10.77

25.77

10

13.860

20.70

10.77

31.47

11

16.940

15.70

10.98

26.68

12

16.940

22.30

10.98

33.28

Notes:

1. " * ", means this data is the worst emission level.

2. C.F (dB) = LISN Factor (dB) + Cable Loss (dB).

3. Measurement (dBV) = Reading (dBV) + C.F (dB).

15 of 73

Margin (dB) -18.76 -11.66 -23.59 -13.49 -16.88 -18.48 -25.32 -27.12 -24.23 -28.53 -23.32 -26.72

Limit (dBV) 55.89 65.89 55.21 65.21 48.21 58.21 46.00 56.00 50.00 60.00 50.00 60.00

Detector
Average QP
Average QP
Average QP
Average QP
Average QP
Average QP

Report No.: 2408RSU020-U8

Site Test Engineer Factor EUT Test Mode

WZ-SR2 Linda Wei ENV216_101683_L1_Filter Off_C OmniAccess Stellar (OAW-AP1521) Mode 2, Power Port

Test Date Temp./Humidity Polarity Test Voltage

2024-11-04 22.5C/65.2% Line AC 120V/60Hz

Frequency No Mark
(MHz)

Reading (dBV)

C.F

Measurement

(dB)

(dBV)

1

0.158

21.60

9.82

31.42

2 *

0.158

38.80

9.82

48.62

3

0.178

18.40

9.82

28.22

4

0.178

35.70

9.82

45.52

5

0.514

-5.60

9.93

4.33

6

0.514

9.20

9.93

19.13

7

2.900

-4.00

10.15

6.15

8

2.900

6.40

10.15

16.55

9

13.260

12.30

10.48

22.78

10

13.260

18.00

10.48

28.48

11

24.140

14.10

10.89

24.99

12

24.140

18.60

10.89

29.49

Notes:

1. " * ", means this data is the worst emission level.

2. C.F (dB) = LISN Factor (dB) + Cable Loss (dB).

3. Measurement (dBV) = Reading (dBV) + C.F (dB).

16 of 73

Margin (dB) -24.15 -16.95 -26.36 -19.06 -41.67 -36.87 -39.85 -39.45 -27.22 -31.52 -25.01 -30.51

Limit (dBV) 55.57 65.57 54.58 64.58 46.00 56.00 46.00 56.00 50.00 60.00 50.00 60.00

Detector
Average QP
Average QP
Average QP
Average QP
Average QP
Average QP

Report No.: 2408RSU020-U8

Site Test Engineer Factor EUT Test Mode

WZ-SR2 Linda Wei ENV216_101683_N_Filter Off_C OmniAccess Stellar (OAW-AP1521) Mode 2, Power Port

Test Date Temp./Humidity Polarity Test Voltage

2024-11-04 22.5C/65.2% Neutral AC 120V/60Hz

Frequency No Mark
(MHz)

Reading (dBV)

C.F

Measurement

(dB)

(dBV)

1

0.150

20.80

10.13

30.93

2 *

0.150

39.50

10.13

49.63

3

0.178

17.80

10.11

27.91

4

0.178

35.40

10.11

45.51

5

0.204

13.20

10.10

23.30

6

0.204

31.40

10.10

41.50

7

2.980

-3.50

10.41

6.91

8

2.980

8.60

10.41

19.01

9

13.530

11.80

10.76

22.56

10

13.530

17.70

10.76

28.46

11

24.140

14.50

11.13

25.63

12

24.140

18.40

11.13

29.53

Notes:

1. " * ", means this data is the worst emission level.

2. C.F (dB) = LISN Factor (dB) + Cable Loss (dB).

3. Measurement (dBV) = Reading (dBV) + C.F (dB).

17 of 73

Margin (dB) -25.07 -16.37 -26.66 -19.06 -30.14 -21.94 -39.10 -37.00 -27.44 -31.54 -24.37 -30.47

Limit (dBV) 56.00 66.00 54.58 64.58 53.45 63.45 46.00 56.00 50.00 60.00 50.00 60.00

Detector
Average QP
Average QP
Average QP
Average QP
Average QP
Average QP

Report No.: 2408RSU020-U8

Site Test Engineer Factor EUT Test Mode

SIP-SR2 Henry Wang SIP-SR2-ENV216_101684_C OmniAccess Stellar (OAW-AP1521) Mode 3, Power Port

Test Date Temp./Humidity Polarity Test Voltage

2024-11-12 22.1C/60.6% Line AC 120V/60Hz

Frequency No Mark
(MHz)

Reading (dBV)

C.F

Measurement

(dB)

(dBV)

1

0.154

23.57

9.65

33.22

2 *

0.154

42.01

9.65

51.66

3

0.166

17.83

9.66

27.49

4

0.166

39.73

9.66

49.38

5

0.178

19.16

9.66

28.82

6

0.178

38.54

9.66

48.19

7

0.186

16.98

9.67

26.65

8

0.186

37.22

9.67

46.89

9

0.194

14.05

9.68

23.73

10

0.194

35.02

9.68

44.70

11

0.382

23.10

9.74

32.84

12

0.382

30.79

9.74

40.53

Notes:

1. " * ", means this data is the worst emission level.

2. C.F (dB) = LISN Factor (dB) + Cable Loss (dB).

3. Measurement (dBV) = Reading (dBV) + C.F (dB).

18 of 73

Margin (dB) -22.56 -14.12 -27.67 -15.78 -25.76 -16.38 -27.57 -17.33 -30.14 -19.17 -15.40 -17.71

Limit (dBV) 55.78 65.78 55.16 65.16 54.58 64.58 54.21 64.21 53.86 63.86 48.24 58.24

Detector
Average QP
Average QP
Average QP
Average QP
Average QP
Average QP

Report No.: 2408RSU020-U8

Site Test Engineer Factor EUT Test Mode

SIP-SR2 Henry Wang SIP-SR2-ENV216_101684_C OmniAccess Stellar (OAW-AP1521) Mode 3, Power Port

Test Date Temp./Humidity Polarity Test Voltage

2024-11-12 22.1C/60.6% Neutral AC 120V/60Hz

Frequency No Mark
(MHz)

Reading (dBV)

C.F

Measurement

(dB)

(dBV)

1

0.154

24.38

9.68

34.06

2 *

0.154

41.79

9.68

51.47

3

0.182

20.37

9.68

30.05

4

0.182

38.66

9.68

48.35

5

0.190

16.77

9.69

26.47

6

0.190

36.53

9.69

46.22

7

0.206

14.62

9.72

24.34

8

0.206

34.04

9.72

43.76

9

0.378

23.45

9.76

33.21

10

0.378

31.03

9.76

40.78

11

16.817

16.36

10.21

26.57

12

16.817

22.56

10.21

32.78

Notes:

1. " * ", means this data is the worst emission level.

2. C.F (dB) = LISN Factor (dB) + Cable Loss (dB).

3. Measurement (dBV) = Reading (dBV) + C.F (dB).

19 of 73

Margin (dB) -21.72 -14.31 -24.34 -16.05 -27.57 -17.81 -29.03 -19.61 -15.12 -17.54 -23.43 -27.22

Limit (dBV) 55.78 65.78 54.39 64.39 54.04 64.04 53.37 63.37 48.32 58.32 50.00 60.00

Detector
Average QP
Average QP
Average QP
Average QP
Average QP
Average QP

Report No.: 2408RSU020-U8

Site Test Engineer Factor EUT Test Mode

SIP-SR2 Henry Wang SIP-SR2-ENV216_101684_C OmniAccess Stellar (OAW-AP1521) Mode 4, Power Port

Test Date Temp./Humidity Polarity Test Voltage

2024-11-12 22.1C/60.6% Line AC 120V/60Hz

Frequency No Mark
(MHz)

Reading (dBV)

C.F

Measurement

(dB)

(dBV)

1

0.158

22.94

9.65

32.59

2 *

0.158

41.47

9.65

51.12

3

0.166

20.07

9.66

29.72

4

0.166

40.88

9.66

50.54

5

0.182

17.87

9.66

27.54

6

0.182

37.49

9.66

47.15

7

0.194

13.74

9.68

23.42

8

0.194

34.67

9.68

44.35

9

0.202

13.60

9.69

23.29

10

0.202

34.02

9.69

43.71

11

0.374

23.12

9.74

32.86

12

0.374

30.70

9.74

40.43

Notes:

1. " * ", means this data is the worst emission level.

2. C.F (dB) = LISN Factor (dB) + Cable Loss (dB).

3. Measurement (dBV) = Reading (dBV) + C.F (dB).

20 of 73

Margin (dB) -22.98 -14.45 -25.44 -14.62 -26.86 -17.24 -30.44 -19.51 -30.24 -19.82 -15.56 -17.98

Limit (dBV) 55.57 65.57 55.16 65.16 54.39 64.39 53.86 63.86 53.53 63.53 48.41 58.41

Detector
Average QP
Average QP
Average QP
Average QP
Average QP
Average QP

Report No.: 2408RSU020-U8

Site Test Engineer Factor EUT Test Mode

SIP-SR2 Henry Wang SIP-SR2-ENV216_101684_C OmniAccess Stellar (OAW-AP1521) Mode 4, Power Port

Test Date Temp./Humidity Polarity Test Voltage

2024-11-12 22.1C/60.6% Neutral AC 120V/60Hz

Frequency No Mark
(MHz)

Reading (dBV)

C.F

Measurement

(dB)

(dBV)

1

0.154

24.33

9.68

34.01

2 *

0.154

41.68

9.68

51.36

3

0.162

22.05

9.68

31.73

4

0.162

41.16

9.68

50.84

5

0.174

19.90

9.68

29.58

6

0.174

39.06

9.68

48.74

7

0.190

16.60

9.69

26.29

8

0.190

36.34

9.69

46.03

9

0.385

23.27

9.76

33.03

10

0.385

31.04

9.76

40.80

11

16.581

16.48

10.21

26.69

12

16.581

22.66

10.21

32.87

Notes:

1. " * ", means this data is the worst emission level.

2. C.F (dB) = LISN Factor (dB) + Cable Loss (dB).

3. Measurement (dBV) = Reading (dBV) + C.F (dB).

21 of 73

Margin (dB) -21.78 -14.43 -23.64 -14.52 -25.19 -16.02 -27.75 -18.00 -15.13 -17.36 -23.31 -27.13

Limit (dBV) 55.79 65.79 55.36 65.36 54.77 64.77 54.04 64.04 48.16 58.16 50.00 60.00

Detector
Average QP
Average QP
Average QP
Average QP
Average QP
Average QP

Report No.: 2408RSU020-U8

Site Test Engineer Factor EUT Test Mode

SIP-SR2 Henry Wang SIP-SR2-ENV216_101684_C OmniAccess Stellar (OAW-AP1521) Mode 5, Power Port

Test Date Temp./Humidity Polarity Test Voltage

2024-11-12 22.1C/60.6% Line AC 120V/60Hz

Frequency No Mark
(MHz)

Reading (dBV)

C.F

Measurement

(dB)

(dBV)

1

0.154

23.19

9.65

32.84

2 *

0.154

41.48

9.65

51.13

3

0.162

20.85

9.65

30.51

4

0.162

41.02

9.65

50.67

5

0.174

18.49

9.66

28.15

6

0.174

38.90

9.66

48.55

7

0.190

15.10

9.67

24.77

8

0.190

36.20

9.67

45.88

9

0.198

13.62

9.68

23.30

10

0.198

34.55

9.68

44.24

11

0.386

23.23

9.74

32.97

12

0.386

30.77

9.74

40.51

Notes:

1. " * ", means this data is the worst emission level.

2. C.F (dB) = LISN Factor (dB) + Cable Loss (dB).

3. Measurement (dBV) = Reading (dBV) + C.F (dB).

22 of 73

Margin (dB) -22.94 -14.65 -24.85 -14.69 -26.62 -16.22 -29.26 -18.16 -30.39 -19.46 -15.18 -17.64

Limit (dBV) 55.78 65.78 55.36 65.36 54.77 64.77 54.04 64.04 53.69 63.69 48.15 58.15

Detector
Average QP
Average QP
Average QP
Average QP
Average QP
Average QP

Report No.: 2408RSU020-U8

Site Test Engineer Factor EUT Test Mode

SIP-SR2 Henry Wang SIP-SR2-ENV216_101684_C OmniAccess Stellar (OAW-AP1521) Mode 5, Power Port

Test Date Temp./Humidity Polarity Test Voltage

2024-11-12 22.1C/60.6% Neutral AC 120V/60Hz

Frequency No Mark
(MHz)

Reading (dBV)

C.F

Measurement

(dB)

(dBV)

1

0.150

23.52

9.68

33.21

2

0.150

41.27

9.68

50.95

3

0.166

21.46

9.68

31.14

4 *

0.166

40.65

9.68

50.33

5

0.178

20.10

9.68

29.78

6

0.178

37.89

9.68

47.57

7

0.194

14.93

9.70

24.63

8

0.194

34.45

9.70

44.15

9

0.202

14.53

9.71

24.24

10

0.202

33.76

9.71

43.47

11

0.374

23.48

9.76

33.23

12

0.374

31.05

9.76

40.80

Notes:

1. " * ", means this data is the worst emission level.

2. C.F (dB) = LISN Factor (dB) + Cable Loss (dB).

3. Measurement (dBV) = Reading (dBV) + C.F (dB).

23 of 73

Margin (dB) -22.79 -15.05 -24.02 -14.82 -24.80 -17.01 -29.23 -19.72 -29.29 -20.06 -15.18 -17.61

Limit (dBV) 56.00 66.00 55.16 65.16 54.58 64.58 53.86 63.86 53.53 63.53 48.41 58.41

Detector
Average QP
Average QP
Average QP
Average QP
Average QP
Average QP

Report No.: 2408RSU020-U8

Site Test Engineer Factor EUT Test Mode

SIP-SR2 Henry Wang SIP-SR2-ENV216_101684_C OmniAccess Stellar (OAW-AP1521) Mode 6, Power Port

Test Date Temp./Humidity Polarity Test Voltage

2024-11-12 22.1C/60.6% Line AC 120V/60Hz

Frequency No Mark
(MHz)

Reading (dBV)

C.F

Measurement

(dB)

(dBV)

1

0.158

23.52

9.65

33.18

2 *

0.158

42.07

9.65

51.73

3

0.174

19.05

9.66

28.71

4

0.174

39.61

9.66

49.26

5

0.182

18.32

9.66

27.98

6

0.182

38.07

9.66

47.73

7

0.194

14.24

9.68

23.92

8

0.194

35.26

9.68

44.94

9

0.202

14.05

9.69

23.74

10

0.202

34.55

9.69

44.24

11

0.378

23.13

9.74

32.86

12

0.378

30.77

9.74

40.51

Notes:

1. " * ", means this data is the worst emission level.

2. C.F (dB) = LISN Factor (dB) + Cable Loss (dB).

3. Measurement (dBV) = Reading (dBV) + C.F (dB).

24 of 73

Margin (dB) -22.39 -13.84 -26.06 -15.50 -26.41 -16.66 -29.94 -18.93 -29.79 -19.29 -15.46 -17.82

Limit (dBV) 55.57 65.57 54.77 64.77 54.39 64.39 53.86 63.86 53.53 63.53 48.32 58.32

Detector
Average QP
Average QP
Average QP
Average QP
Average QP
Average QP

Report No.: 2408RSU020-U8

Site Test Engineer Factor EUT Test Mode

SIP-SR2 Henry Wang SIP-SR2-ENV216_101684_C OmniAccess Stellar (OAW-AP1521) Mode 6, Power Port

Test Date Temp./Humidity Polarity Test Voltage

2024-11-12 22.1C/60.6% Neutral AC 120V/60Hz

Frequency No Mark
(MHz)

Reading (dBV)

C.F

Measurement

(dB)

(dBV)

1

0.158

24.56

9.68

34.24

2 *

0.158

42.26

9.68

51.94

3

0.166

19.01

9.68

28.69

4

0.166

40.00

9.68

49.68

5

0.174

20.61

9.68

30.29

6

0.174

39.76

9.68

49.44

7

0.186

18.59

9.69

28.27

8

0.186

37.55

9.69

47.24

9

0.378

23.33

9.76

33.09

10

0.378

31.00

9.76

40.76

11

16.389

15.53

10.21

25.74

12

16.389

21.70

10.21

31.91

Notes:

1. " * ", means this data is the worst emission level.

2. C.F (dB) = LISN Factor (dB) + Cable Loss (dB).

3. Measurement (dBV) = Reading (dBV) + C.F (dB).

25 of 73

Margin (dB) -21.33 -13.63 -26.47 -15.48 -24.48 -15.33 -25.94 -16.98 -15.23 -17.56 -24.26 -28.09

Limit (dBV) 55.57 65.57 55.16 65.16 54.77 64.77 54.21 64.21 48.32 58.32 50.00 60.00

Detector
Average QP
Average QP
Average QP
Average QP
Average QP
Average QP

Report No.: 2408RSU020-U8

Site Test Engineer Factor EUT Test Mode

SIP-SR2 Henry Wang SIP-SR2-ENV216_101684_C OmniAccess Stellar (OAW-AP1521) Mode 7, Power Port

Test Date Temp./Humidity Polarity Test Voltage

2024-11-12 22.1C/60.6% Line AC 120V/60Hz

Frequency No Mark
(MHz)

Reading (dBV)

C.F

Measurement

(dB)

(dBV)

1

0.154

24.53

9.65

34.18

2 *

0.154

43.28

9.65

52.93

3

0.166

20.70

9.66

30.36

4

0.166

42.25

9.66

51.90

5

0.178

20.17

9.66

29.83

6

0.178

40.49

9.66

50.15

7

0.186

17.76

9.67

27.43

8

0.186

38.25

9.67

47.91

9

0.194

16.75

9.68

26.43

10

0.194

37.92

9.68

47.60

11

0.374

22.95

9.74

32.68

12

0.374

30.75

9.74

40.49

Notes:

1. " * ", means this data is the worst emission level.

2. C.F (dB) = LISN Factor (dB) + Cable Loss (dB).

3. Measurement (dBV) = Reading (dBV) + C.F (dB).

26 of 73

Margin (dB) -21.60 -12.85 -24.80 -13.26 -24.75 -14.43 -26.78 -16.30 -27.43 -16.26 -15.73 -17.92

Limit (dBV) 55.78 65.78 55.16 65.16 54.58 64.58 54.21 64.21 53.86 63.86 48.41 58.41

Detector
Average QP
Average QP
Average QP
Average QP
Average QP
Average QP

Report No.: 2408RSU020-U8

Site Test Engineer Factor EUT Test Mode

SIP-SR2 Henry Wang SIP-SR2-ENV216_101684_C OmniAccess Stellar (OAW-AP1521) Mode 7, Power Port

Test Date Temp./Humidity Polarity Test Voltage

2024-11-12 22.1C/60.6% Neutral AC 120V/60Hz

Frequency No Mark
(MHz)

Reading (dBV)

C.F

Measurement

(dB)

(dBV)

1

0.154

24.95

9.68

34.63

2 *

0.154

42.74

9.68

52.42

3

0.162

23.76

9.68

33.44

4

0.162

42.27

9.68

51.95

5

0.174

21.02

9.68

30.70

6

0.174

40.14

9.68

49.82

7

0.190

17.22

9.69

26.91

8

0.190

37.31

9.69

47.00

9

0.378

23.30

9.76

33.06

10

0.378

30.86

9.76

40.62

11

16.569

16.25

10.21

26.46

12

16.569

22.40

10.21

32.61

Notes:

1. " * ", means this data is the worst emission level.

2. C.F (dB) = LISN Factor (dB) + Cable Loss (dB).

3. Measurement (dBV) = Reading (dBV) + C.F (dB).

27 of 73

Margin (dB) -21.15 -13.36 -21.92 -13.41 -24.07 -14.95 -27.13 -17.04 -15.26 -17.71 -23.54 -27.39

Limit (dBV) 55.78 65.78 55.36 65.36 54.77 64.77 54.04 64.04 48.32 58.32 50.00 60.00

Detector
Average QP
Average QP
Average QP
Average QP
Average QP
Average QP

Report No.: 2408RSU020-U8

5.3. Radiated Emission

5.3.1. Test Limit

FCC Part 15.109 / RSS-Gen / ICES-003 Issue 7 - 3.2.2 Class B Limits

Frequency

Distance

Level

Detector

(MHz)

(m)

(dBV/m)

Function

30 - 88

3

40

Quasi-peak

88 - 216

3

43.5

Quasi-peak

216 - 230

3

46

Quasi-peak

230 - 960

3

46 / 47 Note 3

Quasi-peak

960 - 1000

3

54

Quasi-peak

Above 1000

3

54

Average

74

Peak

Note 1: The lower limit shall apply at the transition frequency.

Note 2: Distance refers to the distance in meters between the measuring instrument antenna and the closed

point of any part of the device or system.

Note 3: In the range of 230MHz to 960MHz, the limit of FCC Part 15.109 is more stringent than the limit of

ICES-003 Issue 7 and RSS-Gen, so only the limit of FCC Part 15.109 is shown in the test data.

28 of 73

5.3.2. Test Setup Below 1GHz Test Setup:

Report No.: 2408RSU020-U8

Above 1GHz Test Setup: 29 of 73

Report No.: 2408RSU020-U8

5.3.3. Test Result

Site Test Engineer Factor EUT Test Mode

WZ-AC1 Dick Shen VULB 9168_25-1000MHz OmniAccess Stellar (OAW-AP1521) Mode 1

Test Date Temp./Humidity Polarity Test Voltage

2024-10-27 26.1C/53.2% Horizontal AC 120V/60Hz

Frequency No Mark
(MHz)

Reading (dBV)

C.F (dB/m)

Measurement (dBV/m)

1

171.453

6.82

18.11

24.93

2

368.628

9.76

20.47

30.23

3

422.058

6.79

21.87

28.66

4

800.101

8.49

29.38

37.87

5 * 841.539

10.41

29.59

40.00

6

961.700

13.10

30.82

43.92

Notes:

1. " * ", means this data is the worst emission level.

2. C.F (dB/m) = Antenna Factor (dB/m) + Cable Loss (dB).

3. Measurement(dBV/m) = Reading(dBV) + C.F (dB/m).

Margin (dB) -18.57 -15.77 -17.34 -8.13 -6.00 -10.08

Limit (dBV/m)
43.50 46.00 46.00 46.00 46.00 54.00

Detector
QP QP QP QP QP QP

30 of 73

Report No.: 2408RSU020-U8

Site Test Engineer Factor EUT Test Mode

WZ-AC1 Dick Shen VULB 9168_25-1000MHz OmniAccess Stellar (OAW-AP1521) Mode 1

Test Date Temp./Humidity Polarity Test Voltage

2024-10-27 26.1C/53.2% Vertical AC 120V/60Hz

Frequency No Mark
(MHz)

Reading (dBV)

C.F (dB/m)

Measurement (dBV/m)

1 *

46.601

13.60

18.36

31.96

2

170.493

9.59

18.17

27.76

3

250.038

14.82

16.95

31.78

4

294.320

6.54

18.66

25.20

5

498.375

3.50

23.55

27.05

6

961.825

2.48

30.82

33.30

Notes:

1. " * ", means this data is the worst emission level.

2. C.F (dB/m) = Antenna Factor (dB/m) + Cable Loss (dB).

3. Measurement(dBV/m) = Reading(dBV) + C.F (dB/m).

Margin (dB) -8.04 -15.74 -14.22 -20.80 -18.95 -20.70

Limit (dBV/m)
40.00 43.50 46.00 46.00 46.00 54.00

Detector
QP QP QP QP QP QP

31 of 73

Report No.: 2408RSU020-U8

Site Test Engineer Factor EUT Test Mode

WZ-AC1 Dick Shen BBHA 9120D_1167_1-18GHz OmniAccess Stellar (OAW-AP1521) Mode 1

Test Date Temp./Humidity Polarity Test Voltage

2024-10-27 26.1C/53.2% Horizontal AC 120V/60Hz

Frequency No Mark
(MHz)

Reading (dBV)

C.F (dB/m)

Measurement (dBV/m)

1 * 9690.400

31.20

14.04

45.24

2

9690.400

35.76

14.04

49.80

3

14251.500 27.80

15.73

43.53

4

14251.500 35.08

15.73

50.82

5

17935.400 21.00

21.95

42.95

6

17935.400 36.16

21.95

58.11

Notes:

1. " * ", means this data is the worst emission level.

2. C.F (dB/m) = Antenna Factor (dB/m) + Cable Loss (dB) - AMP (dB).

3. Measurement(dBV/m) = Reading(dBV) + C.F (dB/m).

Margin (dB) -8.76 -24.20 -10.47 -23.18 -11.05 -15.89

Limit (dBV/m)
54.00 74.00 54.00 74.00 54.00 74.00

Detector
Average Peak
Average Peak
Average Peak

32 of 73

Report No.: 2408RSU020-U8

Site Test Engineer Factor EUT Test Mode

WZ-AC1 Dick Shen BBHA 9120D_1167_1-18GHz OmniAccess Stellar (OAW-AP1521) Mode 1

Test Date Temp./Humidity Polarity Test Voltage

2024-10-27 26.1C/53.2% Vertical AC 120V/60Hz

Frequency No Mark
(MHz)

Reading (dBV)

C.F (dB/m)

Measurement (dBV/m)

1 * 10538.700 30.32

14.89

45.21

2

10538.700 35.31

14.89

50.20

3

14594.900 25.30

15.69

40.99

4

14594.900 36.15

15.69

51.85

5

17996.600 20.56

22.59

43.15

6

17996.600 34.25

22.59

56.84

Notes:

1. " * ", means this data is the worst emission level.

2. C.F (dB/m) = Antenna Factor (dB/m) + Cable Loss (dB) - AMP (dB).

3. Measurement(dBV/m) = Reading(dBV) + C.F (dB/m).

Margin (dB) -8.79 -23.80 -13.01 -22.15 -10.85 -17.16

Limit (dBV/m)
54.00 74.00 54.00 74.00 54.00 74.00

Detector
Average Peak
Average Peak
Average Peak

33 of 73

Report No.: 2408RSU020-U8

Site Test Engineer Factor EUT Test Mode

WZ-AC1 Ajin Fan BBHA 9170_549_18-40GHz OmniAccess Stellar (OAW-AP1521) Mode 1

Test Date Temp./Humidity Polarity Test Voltage

2024-11-07 26.1C/53.2% Horizontal AC 120V/60Hz

Frequency No Mark
(MHz)

Reading (dBV)

C.F (dB/m)

Measurement (dBV/m)

1

20457.400 42.10

-9.13

32.97

2

20457.400 57.35

-9.13

48.22

3

26815.400 39.50

-5.48

34.02

4

26815.400 54.06

-5.48

48.59

5 * 39111.200 40.40

-0.90

39.50

6

39111.200 54.87

-0.90

53.97

Notes:

1. " * ", means this data is the worst emission level.

2. C.F (dB/m) = Antenna Factor (dB/m) + Cable Loss (dB) - AMP (dB).

3. Measurement(dBV/m) = Reading(dBV) + C.F (dB/m).

Margin (dB) -21.03 -25.78 -19.98 -25.41 -14.50 -20.03

Limit (dBV/m)
54.00 74.00 54.00 74.00 54.00 74.00

Detector
Average Peak
Average Peak
Average Peak

34 of 73

Report No.: 2408RSU020-U8

Site Test Engineer Factor EUT Test Mode

WZ-AC1 Ajin Fan BBHA 9170_549_18-40GHz OmniAccess Stellar (OAW-AP1521) Mode 1

Test Date Temp./Humidity Polarity Test Voltage

2024-11-07 26.1C/53.2% Vertical AC 120V/60Hz

Frequency No Mark
(MHz)

Reading (dBV)

C.F (dB/m)

Measurement (dBV/m)

1

22991.800 39.60

-6.55

33.05

2

22991.800 54.34

-6.55

47.79

3

29583.000 41.10

-6.03

35.07

4

29583.000 56.13

-6.03

50.10

5 * 39859.200 40.80

-0.06

40.74

6

39859.200 53.76

-0.06

53.70

Notes:

1. " * ", means this data is the worst emission level.

2. C.F (dB/m) = Antenna Factor (dB/m) + Cable Loss (dB) - AMP (dB).

3. Measurement(dBV/m) = Reading(dBV) + C.F (dB/m).

Margin (dB) -20.95 -26.21 -18.93 -23.90 -13.26 -20.30

Limit (dBV/m)
54.00 74.00 54.00 74.00 54.00 74.00

Detector
Average Peak
Average Peak
Average Peak

35 of 73

Report No.: 2408RSU020-U8

Site Test Engineer Factor EUT Test Mode

WZ-AC2 Ajin Fan VULB 9162_30-7000MHz OmniAccess Stellar (OAW-AP1521) Mode 2

Test Date Temp./Humidity Polarity Test Voltage

2024-11-05 25.8C/25.8% Horizontal By POE

Frequency No Mark
(MHz)

Reading (dBV)

C.F (dB/m)

Measurement (dBV/m)

1

48.236

0.25

20.47

20.72

2

202.236

12.25

18.86

31.11

3 * 250.000

21.09

20.20

41.29

4

343.116

14.02

22.73

36.75

5

442.541

9.60

24.16

33.76

6

799.986

8.77

30.69

39.46

Notes:

1. " * ", means this data is the worst emission level.

2. C.F (dB/m) = Antenna Factor (dB/m) + Cable Loss (dB).

3. Measurement(dBV/m) = Reading(dBV) + C.F (dB/m).

Margin (dB) -19.28 -12.39 -4.71 -9.25 -12.24 -6.54

Limit (dBV/m)
40.00 43.50 46.00 46.00 46.00 46.00

Detector
QP QP QP QP QP QP

36 of 73

Report No.: 2408RSU020-U8

Site Test Engineer Factor EUT Test Mode

WZ-AC2 Ajin Fan VULB 9162_30-7000MHz OmniAccess Stellar (OAW-AP1521) Mode 2

Test Date Temp./Humidity Polarity Test Voltage

2024-11-05 25.8C/25.8% Vertical By POE

Frequency No Mark
(MHz)

Reading (dBV)

C.F (dB/m)

Measurement (dBV/m)

1 *

34.539

19.45

17.44

36.89

2

58.033

12.11

19.76

31.87

3

200.526

10.31

18.98

29.29

4

346.996

14.70

22.95

37.65

5

553.606

9.58

26.50

36.08

6

799.986

6.47

30.69

37.16

Notes:

1. " * ", means this data is the worst emission level.

2. C.F (dB/m) = Antenna Factor (dB/m) + Cable Loss (dB).

3. Measurement(dBV/m) = Reading(dBV) + C.F (dB/m).

Margin (dB) -3.11 -8.13 -14.21 -8.35 -9.92 -8.84

Limit (dBV/m)
40.00 40.00 43.50 46.00 46.00 46.00

Detector
QP QP QP QP QP QP

37 of 73

Report No.: 2408RSU020-U8

Site Test Engineer Factor EUT Test Mode

WZ-AC2 Ajin Fan BBHA 9120D_1457_1-18GHz OmniAccess Stellar (OAW-AP1521) Mode 2

Test Date Temp./Humidity Polarity Test Voltage

2024-11-05 25.8C/25.8% Horizontal By POE

Frequency No Mark
(MHz)

Reading (dBV)

C.F (dB/m)

Measurement (dBV/m)

1

11572.300 18.89

17.06

35.95

2

11572.300 33.87

17.06

50.93

3

14929.800 19.80

19.19

38.99

4

14929.800 33.82

19.19

53.01

5 * 17962.600 19.35

27.95

47.30

6

17962.600 35.17

27.95

63.12

Notes:

1. " * ", means this data is the worst emission level.

2. C.F (dB/m) = Antenna Factor (dB/m) + Cable Loss (dB) - AMP (dB).

3. Measurement(dBV/m) = Reading(dBV) + C.F (dB/m).

Margin (dB) -18.05 -23.07 -15.01 -20.99 -6.70 -10.88

Limit (dBV/m)
54.00 74.00 54.00 74.00 54.00 74.00

Detector
Average Peak
Average Peak
Average Peak

38 of 73

Report No.: 2408RSU020-U8

Site Test Engineer Factor EUT Test Mode

WZ-AC2 Ajin Fan BBHA 9120D_1457_1-18GHz OmniAccess Stellar (OAW-AP1521) Mode 2

Test Date Temp./Humidity Polarity Test Voltage

2024-11-05 25.8C/25.8% Vertical By POE

Frequency No Mark
(MHz)

Reading (dBV)

C.F (dB/m)

Measurement (dBV/m)

1

9647.900

23.98

12.77

36.75

2

9647.900

37.57

12.77

50.33

3

14521.800 19.20

19.00

38.20

4

14521.800 34.27

19.00

53.27

5 * 17986.400 19.56

28.56

48.12

6

17986.400 34.01

28.56

62.58

Notes:

1. " * ", means this data is the worst emission level.

2. C.F (dB/m) = Antenna Factor (dB/m) + Cable Loss (dB) - AMP (dB).

3. Measurement(dBV/m) = Reading(dBV) + C.F (dB/m).

Margin (dB) -17.25 -23.67 -15.80 -20.73 -5.88 -11.42

Limit (dBV/m)
54.00 74.00 54.00 74.00 54.00 74.00

Detector
Average Peak
Average Peak
Average Peak

39 of 73

Report No.: 2408RSU020-U8

Site Test Engineer Factor EUT Test Mode

WZ-AC1 Ajin Fan BBHA 9170_549_18-40GHz OmniAccess Stellar (OAW-AP1521) Mode 2

Test Date Temp./Humidity Polarity Test Voltage

2024-11-07 26.1C/53.2% Horizontal By POE

Frequency No Mark
(MHz)

Reading (dBV)

C.F (dB/m)

Measurement (dBV/m)

1

21535.400 39.00

-8.22

30.78

2

21535.400 55.67

-8.22

47.44

3

26971.600 41.30

-6.22

35.08

4

26971.600 55.47

-6.22

49.25

5 * 39419.200 38.80

-0.31

38.49

6

39419.200 54.66

-0.31

54.35

Notes:

1. " * ", means this data is the worst emission level.

2. C.F (dB/m) = Antenna Factor (dB/m) + Cable Loss (dB) - AMP (dB).

3. Measurement(dBV/m) = Reading(dBV) + C.F (dB/m).

Margin (dB) -23.22 -26.56 -18.92 -24.75 -15.51 -19.65

Limit (dBV/m)
54.00 74.00 54.00 74.00 54.00 74.00

Detector
Average Peak
Average Peak
Average Peak

40 of 73

Report No.: 2408RSU020-U8

Site Test Engineer Factor EUT Test Mode

WZ-AC1 Ajin Fan BBHA 9170_549_18-40GHz OmniAccess Stellar (OAW-AP1521) Mode 2

Test Date Temp./Humidity Polarity Test Voltage

2024-11-07 26.1C/53.2% Vertical By POE

Frequency No Mark
(MHz)

Reading (dBV)

C.F (dB/m)

Measurement (dBV/m)

1

23154.600 39.20

-6.65

32.55

2

23154.600 54.49

-6.65

47.84

3

26800.000 39.70

-5.35

34.35

4

26800.000 54.04

-5.35

48.69

5 * 39282.800 38.60

-0.51

38.09

6

39282.800 53.94

-0.51

53.42

Notes:

1. " * ", means this data is the worst emission level.

2. C.F (dB/m) = Antenna Factor (dB/m) + Cable Loss (dB) - AMP (dB).

3. Measurement(dBV/m) = Reading(dBV) + C.F (dB/m).

Margin (dB) -21.45 -26.16 -19.65 -25.31 -15.91 -20.58

Limit (dBV/m)
54.00 74.00 54.00 74.00 54.00 74.00

Detector
Average Peak
Average Peak
Average Peak

41 of 73

Site Temperature Limit Factor EUT Test Mode

Report No.: 2408RSU020-U8

SIP-AC3 19.3C FCC_Part 15.209_RSE(3m)_QP VULB 9168_00997_25-2000MHz OmniAccess Stellar (OAW-AP1521) Mode 3

Test Date Humidity Test Engineer Polarity Test Voltage

2024-12-18 35.2% Fusco Pan Horizontal AC 120V/60Hz

Frequency No Mark
(MHz)

Reading (dBV)

C.F (dB/m)

Measurement (dBV/m)

1

150.116

6.00

18.44

24.44

2

172.236

12.50

17.65

30.15

3 *

250.038

18.80

17.02

35.82

4

300.052

12.40

18.70

31.10

5

376.995

11.40

20.57

31.97

6

922.192

-9.80

30.03

20.23

Notes:

1. " * ", means this data is the worst emission level.

2. C.F (dB/m) = Antenna Factor (dB/m) + Cable Loss (dB).

3. Measurement (dBV/m) = Reading (dBV) + C.F (dB/m).

Margin (dB) -19.06 -13.35 -10.18 -14.90 -14.03 -25.77

Limit (dBV/m)
43.50 43.50 46.00 46.00 46.00 46.00

Detector
QP QP QP QP QP QP

42 of 73

Site Temperature Limit Factor EUT Test Mode

Report No.: 2408RSU020-U8

SIP-AC3 19.3C FCC_Part 15.209_RSE(3m)_QP VULB 9168_00997_25-2000MHz OmniAccess Stellar (OAW-AP1521) Mode 3

Test Date Humidity Test Engineer Polarity Test Voltage

2024-12-18 35.2% Fusco Pan Vertical AC 120V/60Hz

Frequency No Mark
(MHz)

Reading (dBV)

C.F (dB/m)

Measurement (dBV/m)

1

38.292

11.20

17.83

29.03

2

48.860

7.60

18.65

26.25

3

58.264

10.40

18.25

28.65

4

82.013

16.30

13.74

30.04

5 *

177.323

20.40

17.12

37.52

6

250.038

20.80

17.02

37.82

Notes:

1. " * ", means this data is the worst emission level.

2. C.F (dB/m) = Antenna Factor (dB/m) + Cable Loss (dB).

3. Measurement (dBV/m) = Reading (dBV) + C.F (dB/m).

Margin (dB) -10.97 -13.75 -11.35 -9.96 -5.98 -8.18

Limit (dBV/m)
40.00 40.00 40.00 40.00 43.50 46.00

Detector
QP QP QP QP QP QP

43 of 73

Report No.: 2408RSU020-U8

Site Test Engineer Factor EUT Test Mode

SIP-AC3 Mero Zhou HF907_102861_1-18GHz OmniAccess Stellar (OAW-AP1521) Mode 3

Test Date Temp./Humidity Polarity Test Voltage

2024-11-07 21.1C/51.5% Horizontal AC 120V/60Hz

Frequency No Mark
(MHz)

Reading (dBV)

C.F (dB/m)

Measurement (dBV/m)

Margin (dB)

1

9647.900

54.31

-1.55

52.76

-21.24

2 * 9647.900

49.36

-1.55

47.81

-6.19

3

16109.600

47.06

5.67

52.73

-21.27

4

16109.600

34.37

5.67

40.04

-13.96

5

17532.500

45.60

8.81

54.40

-19.60

6

17532.500

31.69

8.81

40.50

-13.50

Notes:

1. " * ", means this data is the worst emission level.

2. C.F (dB/m) = Antenna Factor (dB/m) + Cable Loss (dB) - AMP (dB).

3. Measurement(dBV/m) = Reading(dBV) + C.F (dB/m).

Limit (dBV/m)
74.00 54.00 74.00 54.00 74.00 54.00

Detector
Peak Average
Peak Average
Peak Average

44 of 73

Report No.: 2408RSU020-U8

Site Test Engineer Factor EUT Test Mode

SIP-AC3 Mero Zhou HF907_102861_1-18GHz OmniAccess Stellar (OAW-AP1521) Mode 3

Test Date Temp./Humidity Polarity Test Voltage

2024-11-07 21.1C/51.5% Vertical AC 120V/60Hz

Frequency No Mark
(MHz)

Reading (dBV)

C.F (dB/m)

Measurement (dBV/m)

Margin (dB)

1

9647.900

52.38

-1.55

50.83

-23.17

2 * 9647.900

47.51

-1.55

45.96

-8.04

3

14023.700

47.02

3.48

50.50

-23.50

4

14023.700

34.95

3.48

38.43

-15.57

5

17959.200

43.24

10.24

53.48

-20.52

6

17959.200

31.54

10.24

41.78

-12.22

Notes:

1. " * ", means this data is the worst emission level.

2. C.F (dB/m) = Antenna Factor (dB/m) + Cable Loss (dB) - AMP (dB).

3. Measurement(dBV/m) = Reading(dBV) + C.F (dB/m).

Limit (dBV/m)
74.00 54.00 74.00 54.00 74.00 54.00

Detector
Peak Average
Peak Average
Peak Average

45 of 73

Report No.: 2408RSU020-U8

Site Test Engineer Factor EUT Test Mode

SIP-AC3 Mero Zhou BBHA 9170_00934_18-40GHz OmniAccess Stellar (OAW-AP1521) Mode 3

Test Date Temp./Humidity Polarity Test Voltage

2024-11-15 20.7C/62.4% Horizontal AC 120V/60Hz

Frequency No Mark
(MHz)

Reading (dBV)

C.F (dB/m)

Measurement (dBV/m)

Margin (dB)

1

31094.400

57.59

-9.10

48.49

-25.51

2

31094.400

45.75

-9.10

36.65

-17.35

3

37749.400

55.06

-2.78

52.27

-21.73

4

37749.400

42.64

-2.78

39.86

-14.14

5

39249.800

52.52

0.80

53.31

-20.69

6 * 39249.800

41.34

0.80

42.14

-11.86

Notes:

1. " * ", means this data is the worst emission level.

2. C.F (dB/m) = Antenna Factor (dB/m) + Cable Loss (dB) - AMP (dB).

3. Measurement(dBV/m) = Reading(dBV) + C.F (dB/m).

Limit (dBV/m)
74.00 54.00 74.00 54.00 74.00 54.00

Detector
Peak Average
Peak Average
Peak Average

46 of 73

Report No.: 2408RSU020-U8

Site Test Engineer Factor EUT Test Mode

SIP-AC3 Mero Zhou BBHA 9170_00934_18-40GHz OmniAccess Stellar (OAW-AP1521) Mode 3

Test Date Temp./Humidity Polarity Test Voltage

2024-11-15 20.7C/62.4% Vertical AC 120V/60Hz

Frequency No Mark
(MHz)

Reading (dBV)

C.F (dB/m)

Measurement (dBV/m)

Margin (dB)

1

30498.200

57.70

-8.51

49.19

-24.81

2

30498.200

45.64

-8.51

37.13

-16.87

3

37734.000

53.68

-2.86

50.82

-23.18

4

37734.000

42.69

-2.86

39.83

-14.17

5

39203.600

52.52

-0.07

52.45

-21.55

6 * 39203.600

41.62

-0.07

41.55

-12.45

Notes:

1. " * ", means this data is the worst emission level.

2. C.F (dB/m) = Antenna Factor (dB/m) + Cable Loss (dB) - AMP (dB).

3. Measurement(dBV/m) = Reading(dBV) + C.F (dB/m).

Limit (dBV/m)
74.00 54.00 74.00 54.00 74.00 54.00

Detector
Peak Average
Peak Average
Peak Average

47 of 73

Site Temperature Limit Factor EUT Test Mode

Report No.: 2408RSU020-U8

SIP-AC3 19.3C FCC_Part 15.209_RSE(3m)_QP VULB 9168_00997_25-2000MHz OmniAccess Stellar (OAW-AP1521) Mode 4

Test Date Humidity Test Engineer Polarity Test Voltage

2024-12-18 35.2% Fusco Pan Horizontal AC 120V/60Hz

Frequency No Mark
(MHz)

Reading (dBV)

C.F (dB/m)

Measurement (dBV/m)

1

165.023

11.63

18.11

29.74

2

199.986

11.38

15.11

26.49

3 *

250.038

20.30

17.02

37.32

4

300.052

11.40

18.70

30.09

5

379.116

9.24

20.61

29.84

6

947.763

-9.40

30.24

20.84

Notes:

1. " * ", means this data is the worst emission level.

2. C.F (dB/m) = Antenna Factor (dB/m) + Cable Loss (dB).

3. Measurement (dBV/m) = Reading (dBV) + C.F (dB/m).

Margin (dB) -13.76 -17.01 -8.68 -15.91 -16.16 -25.16

Limit (dBV/m)
43.50 43.50 46.00 46.00 46.00 46.00

Detector
QP QP QP QP QP QP

48 of 73

Site Temperature Limit Factor EUT Test Mode

Report No.: 2408RSU020-U8

SIP-AC3 19.3C FCC_Part 15.209_RSE(3m)_QP VULB 9168_00997_25-2000MHz OmniAccess Stellar (OAW-AP1521) Mode 4

Test Date Humidity Test Engineer Polarity Test Voltage

2024-12-18 35.2% Fusco Pan Vertical AC 120V/60Hz

Frequency No Mark
(MHz)

Reading (dBV)

C.F (dB/m)

Measurement (dBV/m)

1

38.012

10.43

17.80

28.23

2

58.469

10.23

18.23

28.46

3

80.137

15.39

14.17

29.56

4 *

176.640

18.20

17.19

35.39

5

250.038

19.03

17.02

36.06

6

378.584

9.13

20.60

29.73

Notes:

1. " * ", means this data is the worst emission level.

2. C.F (dB/m) = Antenna Factor (dB/m) + Cable Loss (dB).

3. Measurement (dBV/m) = Reading (dBV) + C.F (dB/m).

Margin (dB) -11.77 -11.54 -10.44 -8.11 -9.94 -16.27

Limit (dBV/m)
40.00 40.00 40.00 43.50 46.00 46.00

Detector
QP QP QP QP QP QP

49 of 73

Report No.: 2408RSU020-U8

Site Test Engineer Factor EUT Test Mode

SIP-AC3 Mero Zhou HF907_102861_1-18GHz OmniAccess Stellar (OAW-AP1521) Mode 4

Test Date Temp./Humidity Polarity Test Voltage

2024-11-07 21.1C/51.5% Horizontal AC 120V/60Hz

Frequency No Mark
(MHz)

Reading (dBV)

C.F (dB/m)

Measurement (dBV/m)

Margin (dB)

1

9647.900

53.48

-1.55

51.93

-22.07

2 * 9647.900

48.49

-1.55

46.94

-7.06

3

14144.400

47.14

3.20

50.35

-23.65

4

14144.400

34.68

3.20

37.88

-16.12

5

17467.900

45.88

8.42

54.31

-19.69

6

17467.900

31.75

8.42

40.17

-13.83

Notes:

1. " * ", means this data is the worst emission level.

2. C.F (dB/m) = Antenna Factor (dB/m) + Cable Loss (dB) - AMP (dB).

3. Measurement(dBV/m) = Reading(dBV) + C.F (dB/m).

Limit (dBV/m)
74.00 54.00 74.00 54.00 74.00 54.00

Detector
Peak Average
Peak Average
Peak Average

50 of 73

Report No.: 2408RSU020-U8

Site Test Engineer Factor EUT Test Mode

SIP-AC3 Mero Zhou HF907_102861_1-18GHz OmniAccess Stellar (OAW-AP1521) Mode 4

Test Date Temp./Humidity Polarity Test Voltage

2024-11-07 21.1C/51.5% Vertical AC 120V/60Hz

Frequency No Mark
(MHz)

Reading (dBV)

C.F (dB/m)

Measurement (dBV/m)

Margin (dB)

1

9647.900

53.08

-1.55

51.52

-22.48

2 * 9647.900

48.57

-1.55

47.02

-6.98

3

14090.000

46.88

2.66

49.54

-24.46

4

14090.000

34.69

2.66

37.35

-16.65

5

17714.400

45.48

8.19

53.67

-20.33

6

17714.400

31.68

8.19

39.87

-14.13

Notes:

1. " * ", means this data is the worst emission level.

2. C.F (dB/m) = Antenna Factor (dB/m) + Cable Loss (dB) - AMP (dB).

3. Measurement(dBV/m) = Reading(dBV) + C.F (dB/m).

Limit (dBV/m)
74.00 54.00 74.00 54.00 74.00 54.00

Detector
Peak Average
Peak Average
Peak Average

51 of 73

Report No.: 2408RSU020-U8

Site Test Engineer Factor EUT Test Mode

SIP-AC3 Mero Zhou BBHA 9170_00934_18-40GHz OmniAccess Stellar (OAW-AP1521) Mode 4

Test Date Temp./Humidity Polarity Test Voltage

2024-11-15 20.7C/62.4% Horizontal AC 120V/60Hz

Frequency No Mark
(MHz)

Reading (dBV)

C.F (dB/m)

Measurement (dBV/m)

Margin (dB)

1

30500.400

57.67

-8.49

49.18

-24.82

2

30500.400

44.79

-8.49

36.30

-17.70

3

37764.800

54.57

-2.77

51.80

-22.20

4

37764.800

42.19

-2.77

39.42

-14.58

5

39274.000

53.17

-0.11

53.05

-20.95

6 * 39274.000

41.34

-0.11

41.23

-12.77

Notes:

1. " * ", means this data is the worst emission level.

2. C.F (dB/m) = Antenna Factor (dB/m) + Cable Loss (dB) - AMP (dB).

3. Measurement(dBV/m) = Reading(dBV) + C.F (dB/m).

Limit (dBV/m)
74.00 54.00 74.00 54.00 74.00 54.00

Detector
Peak Average
Peak Average
Peak Average

52 of 73

Report No.: 2408RSU020-U8

Site Test Engineer Factor EUT Test Mode

SIP-AC3 Mero Zhou BBHA 9170_00934_18-40GHz OmniAccess Stellar (OAW-AP1521) Mode 4

Test Date Temp./Humidity Polarity Test Voltage

2024-11-15 20.7C/62.4% Vertical AC 120V/60Hz

Frequency No Mark
(MHz)

Reading (dBV)

C.F (dB/m)

Measurement (dBV/m)

Margin (dB)

1

30533.400

57.19

-8.69

48.50

-25.50

2

30533.400

44.69

-8.69

36.00

-18.00

3

35441.600

56.82

-6.79

50.02

-23.98

4

35441.600

42.86

-6.79

36.07

-17.93

5

38908.800

54.43

-0.91

53.52

-20.48

6 * 38908.800

41.75

-0.91

40.84

-13.16

Notes:

1. " * ", means this data is the worst emission level.

2. C.F (dB/m) = Antenna Factor (dB/m) + Cable Loss (dB) - AMP (dB).

3. Measurement(dBV/m) = Reading(dBV) + C.F (dB/m).

Limit (dBV/m)
74.00 54.00 74.00 54.00 74.00 54.00

Detector
Peak Average
Peak Average
Peak Average

53 of 73

Site Temperature Limit Factor EUT Test Mode

Report No.: 2408RSU020-U8

SIP-AC3 19.3C FCC_Part 15.209_RSE(3m)_QP VULB 9168_00997_25-2000MHz OmniAccess Stellar (OAW-AP1521) Mode 5

Test Date Humidity Test Engineer Polarity Test Voltage

2024-12-18 35.2% Fusco Pan Horizontal AC 120V/60Hz

Frequency No Mark
(MHz)

Reading (dBV)

C.F (dB/m)

Measurement (dBV/m)

1

164.330

12.28

18.13

30.41

2

199.986

12.46

15.11

27.57

3 *

250.038

19.30

17.02

36.32

4

300.052

11.04

18.70

29.74

5

378.186

9.49

20.59

30.08

6

750.108

-10.40

28.42

18.02

Notes:

1. " * ", means this data is the worst emission level.

2. C.F (dB/m) = Antenna Factor (dB/m) + Cable Loss (dB).

3. Measurement (dBV/m) = Reading (dBV) + C.F (dB/m).

Margin (dB) -13.09 -15.93 -9.68 -16.26 -15.92 -27.98

Limit (dBV/m)
43.50 43.50 46.00 46.00 46.00 46.00

Detector
QP QP QP QP QP QP

54 of 73

Site Temperature Limit Factor EUT Test Mode

Report No.: 2408RSU020-U8

SIP-AC3 19.3C FCC_Part 15.209_RSE(3m)_QP VULB 9168_00997_25-2000MHz OmniAccess Stellar (OAW-AP1521) Mode 5

Test Date Humidity Test Engineer Polarity Test Voltage

2024-12-18 35.2% Fusco Pan Vertical AC 120V/60Hz

Frequency No Mark
(MHz)

Reading (dBV)

C.F (dB/m)

Measurement (dBV/m)

1

37.998

11.45

17.80

29.25

2

58.551

11.31

18.22

29.53

3

80.277

17.63

14.14

31.77

4 *

173.387

19.06

17.54

36.60

5

250.038

18.99

17.02

36.01

6

395.825

11.79

20.83

32.62

Notes:

1. " * ", means this data is the worst emission level.

2. C.F (dB/m) = Antenna Factor (dB/m) + Cable Loss (dB).

3. Measurement (dBV/m) = Reading (dBV) + C.F (dB/m).

Margin (dB) -10.75 -10.47 -8.23 -6.90 -9.99 -13.38

Limit (dBV/m)
40.00 40.00 40.00 43.50 46.00 46.00

Detector
QP QP QP QP QP QP

55 of 73

Report No.: 2408RSU020-U8

Site Test Engineer Factor EUT Test Mode

SIP-AC3 Mero Zhou HF907_102861_1-18GHz OmniAccess Stellar (OAW-AP1521) Mode 5

Test Date Temp./Humidity Polarity Test Voltage

2024-11-07 21.1C/51.5% Horizontal AC 120V/60Hz

Frequency No Mark
(MHz)

Reading (dBV)

C.F (dB/m)

Measurement (dBV/m)

Margin (dB)

1

9647.900

52.58

-1.55

51.03

-22.97

2 * 9647.900

47.64

-1.55

46.09

-7.91

3

14243.000

46.97

3.23

50.20

-23.80

4

14243.000

34.69

3.23

37.92

-16.08

5

17841.900

44.66

9.21

53.86

-20.14

6

17841.900

31.57

9.21

40.78

-13.22

Notes:

1. " * ", means this data is the worst emission level.

2. C.F (dB/m) = Antenna Factor (dB/m) + Cable Loss (dB) - AMP (dB).

3. Measurement(dBV/m) = Reading(dBV) + C.F (dB/m).

Limit (dBV/m)
74.00 54.00 74.00 54.00 74.00 54.00

Detector
Peak Average
Peak Average
Peak Average

56 of 73

Report No.: 2408RSU020-U8

Site Test Engineer Factor EUT Test Mode

SIP-AC3 Mero Zhou HF907_102861_1-18GHz OmniAccess Stellar (OAW-AP1521) Mode 5

Test Date Temp./Humidity Polarity Test Voltage

2024-11-07 21.1C/51.5% Vertical AC 120V/60Hz

Frequency No Mark
(MHz)

Reading (dBV)

C.F (dB/m)

Measurement (dBV/m)

Margin (dB)

1

9647.900

51.49

-1.55

49.94

-24.06

2 * 9647.900

46.57

-1.55

45.02

-8.98

3

14314.400

46.74

2.86

49.60

-24.40

4

14314.400

34.71

2.86

37.57

-16.43

5

17556.300

45.52

8.40

53.91

-20.09

6

17556.300

31.49

8.40

39.89

-14.11

Notes:

1. " * ", means this data is the worst emission level.

2. C.F (dB/m) = Antenna Factor (dB/m) + Cable Loss (dB) - AMP (dB).

3. Measurement(dBV/m) = Reading(dBV) + C.F (dB/m).

Limit (dBV/m)
74.00 54.00 74.00 54.00 74.00 54.00

Detector
Peak Average
Peak Average
Peak Average

57 of 73

Report No.: 2408RSU020-U8

Site Test Engineer Factor EUT Test Mode

SIP-AC3 Mero Zhou BBHA 9170_00934_18-40GHz OmniAccess Stellar (OAW-AP1521) Mode 5

Test Date Temp./Humidity Polarity Test Voltage

2024-11-15 20.7C/62.4% Horizontal AC 120V/60Hz

Frequency No Mark
(MHz)

Reading (dBV)

C.F (dB/m)

Measurement (dBV/m)

Margin (dB)

1

30639.000

56.85

-8.43

48.42

-25.58

2

30639.000

45.67

-8.43

37.24

-16.76

3

37382.000

55.07

-3.36

51.72

-22.28

4

37382.000

42.76

-3.36

39.40

-14.60

5

39252.000

52.91

0.93

53.84

-20.16

6 * 39252.000

41.28

0.93

42.21

-11.79

Notes:

1. " * ", means this data is the worst emission level.

2. C.F (dB/m) = Antenna Factor (dB/m) + Cable Loss (dB) - AMP (dB).

3. Measurement(dBV/m) = Reading(dBV) + C.F (dB/m).

Limit (dBV/m)
74.00 54.00 74.00 54.00 74.00 54.00

Detector
Peak Average
Peak Average
Peak Average

58 of 73

Report No.: 2408RSU020-U8

Site Test Engineer Factor EUT Test Mode

SIP-AC3 Mero Zhou BBHA 9170_00934_18-40GHz OmniAccess Stellar (OAW-AP1521) Mode 5

Test Date Temp./Humidity Polarity Test Voltage

2024-11-15 20.7C/62.4% Vertical AC 120V/60Hz

Frequency No Mark
(MHz)

Reading (dBV)

C.F (dB/m)

Measurement (dBV/m)

Margin (dB)

1

35575.800

56.44

-6.21

50.23

-23.77

2

35575.800

44.05

-6.21

37.84

-16.16

3

37727.400

55.06

-3.02

52.04

-21.96

4

37727.400

42.39

-3.02

39.37

-14.63

5

38933.000

53.91

-0.93

52.98

-21.02

6 * 38933.000

41.46

-0.93

40.53

-13.47

Notes:

1. " * ", means this data is the worst emission level.

2. C.F (dB/m) = Antenna Factor (dB/m) + Cable Loss (dB) - AMP (dB).

3. Measurement(dBV/m) = Reading(dBV) + C.F (dB/m).

Limit (dBV/m)
74.00 54.00 74.00 54.00 74.00 54.00

Detector
Peak Average
Peak Average
Peak Average

59 of 73

Site Temperature Limit Factor EUT Test Mode

Report No.: 2408RSU020-U8

SIP-AC3 19.3C FCC_Part 15.209_RSE(3m)_QP VULB 9168_00997_25-2000MHz OmniAccess Stellar (OAW-AP1521) Mode 6

Test Date Humidity Test Engineer Polarity Test Voltage

2024-12-18 35.2% Fusco Pan Horizontal AC 120V/60Hz

Frequency No Mark
(MHz)

Reading (dBV)

C.F (dB/m)

Measurement (dBV/m)

1

68.896

3.50

16.54

20.04

2

164.446

10.80

18.13

28.93

3

199.986

12.80

15.11

27.91

4 *

250.038

18.30

17.02

35.32

5

299.946

12.90

18.69

31.59

6

395.132

10.36

20.82

31.18

Notes:

1. " * ", means this data is the worst emission level.

2. C.F (dB/m) = Antenna Factor (dB/m) + Cable Loss (dB).

3. Measurement (dBV/m) = Reading (dBV) + C.F (dB/m).

Margin (dB) -19.96 -14.57 -15.59 -10.68 -14.41 -14.82

Limit (dBV/m)
40.00 43.50 43.50 46.00 46.00 46.00

Detector
QP QP QP QP QP QP

60 of 73

Site Temperature Limit Factor EUT Test Mode

Report No.: 2408RSU020-U8

SIP-AC3 19.3C FCC_Part 15.209_RSE(3m)_QP VULB 9168_00997_25-2000MHz OmniAccess Stellar (OAW-AP1521) Mode 6

Test Date Humidity Test Engineer Polarity Test Voltage

2024-12-18 35.2% Fusco Pan Vertical AC 120V/60Hz

Frequency No Mark
(MHz)

Reading (dBV)

C.F (dB/m)

Measurement (dBV/m)

1

37.733

12.10

17.77

29.87

2

58.963

12.30

18.17

30.47

3

79.048

16.30

14.44

30.74

4 *

169.897

18.23

17.84

36.07

5

250.038

18.60

17.02

35.62

6

395.686

11.60

20.83

32.43

Notes:

1. " * ", means this data is the worst emission level.

2. C.F (dB/m) = Antenna Factor (dB/m) + Cable Loss (dB).

3. Measurement (dBV/m) = Reading (dBV) + C.F (dB/m).

Margin (dB) -10.13 -9.53 -9.26 -7.43 -10.38 -13.57

Limit (dBV/m)
40.00 40.00 40.00 43.50 46.00 46.00

Detector
QP QP QP QP QP QP

61 of 73

Report No.: 2408RSU020-U8

Site Test Engineer Factor EUT Test Mode

SIP-AC3 Mero Zhou HF907_102861_1-18GHz OmniAccess Stellar (OAW-AP1521) Mode 6

Test Date Temp./Humidity Polarity Test Voltage

2024-11-07 21.1C/51.5% Horizontal AC 120V/60Hz

Frequency Reading

No Mark

(MHz)

(dBV)

C.F (dB/m)

Measurement Margin (dBV/m) (dB)

1

9647.900 53.21

-1.55

51.66

-22.34

2 *

9647.900 48.88

-1.55

47.33

-6.67

3

14127.400 48.11

3.37

51.48

-22.52

4

14127.400 34.64

3.37

38.01

-15.99

5

17585.200 46.19

8.15

54.34

-19.66

6

17585.200 31.59

8.15

39.74

-14.26

Notes:

1. " * ", means this data is the worst emission level.

2. C.F (dB/m) = Antenna Factor (dB/m) + Cable Loss (dB) - AMP (dB).

3. Measurement(dBV/m) = Reading(dBV) + C.F (dB/m).

Limit (dBV/m) 74.00 54.00 74.00 54.00 74.00 54.00

Detector
Peak Average Peak Average Peak Average

62 of 73

Report No.: 2408RSU020-U8

Site Test Engineer Factor EUT Test Mode

SIP-AC3 Mero Zhou HF907_102861_1-18GHz OmniAccess Stellar (OAW-AP1521) Mode 6

Test Date Temp./Humidity Polarity Test Voltage

2024-11-07 21.1C/51.5% Vertical AC 120V/60Hz

Frequency No Mark
(MHz)

Reading (dBV)

C.F (dB/m)

Measurement (dBV/m)

Margin (dB)

1

9647.900

52.72

-1.55

51.17

-22.83

2 * 9647.900

48.76

-1.55

47.21

-6.79

3

14124.000

47.07

3.37

50.45

-23.55

4

14124.000

34.76

3.37

38.13

-15.87

5

17454.300

45.40

8.84

54.24

-19.76

6

17454.300

31.86

8.84

40.70

-13.30

Notes:

1. " * ", means this data is the worst emission level.

2. C.F (dB/m) = Antenna Factor (dB/m) + Cable Loss (dB) - AMP (dB).

3. Measurement(dBV/m) = Reading(dBV) + C.F (dB/m).

Limit (dBV/m)
74.00 54.00 74.00 54.00 74.00 54.00

Detector
Peak Average
Peak Average
Peak Average

63 of 73

Report No.: 2408RSU020-U8

Site Test Engineer Factor EUT Test Mode

SIP-AC3 Mero Zhou BBHA 9170_00934_18-40GHz OmniAccess Stellar (OAW-AP1521) Mode 6

Test Date Temp./Humidity Polarity Test Voltage

2024-11-15 20.7C/62.4% Horizontal AC 120V/60Hz

Frequency No Mark
(MHz)

Reading (dBV)

C.F (dB/m)

Measurement (dBV/m)

Margin (dB)

1

30650.000

56.65

-8.32

48.33

-25.67

2

30650.000

45.69

-8.32

37.37

-16.63

3

37749.400

54.67

-2.78

51.89

-22.11

4

37749.400

42.71

-2.78

39.93

-14.07

5

39188.200

53.58

0.00

53.58

-20.42

6 * 39188.200

41.31

0.00

41.31

-12.69

Notes:

1. " * ", means this data is the worst emission level.

2. C.F (dB/m) = Antenna Factor (dB/m) + Cable Loss (dB) - AMP (dB).

3. Measurement(dBV/m) = Reading(dBV) + C.F (dB/m).

Limit (dBV/m)
74.00 54.00 74.00 54.00 74.00 54.00

Detector
Peak Average
Peak Average
Peak Average

64 of 73

Report No.: 2408RSU020-U8

Site Test Engineer Factor EUT Test Mode

SIP-AC3 Mero Zhou BBHA 9170_00934_18-40GHz OmniAccess Stellar (OAW-AP1521) Mode 6

Test Date Temp./Humidity Polarity Test Voltage

2024-11-15 20.7C/62.4% Vertical AC 120V/60Hz

Frequency No Mark
(MHz)

Reading (dBV)

C.F (dB/m)

Measurement (dBV/m)

Margin (dB)

1

35562.600

56.87

-6.43

50.44

-23.56

2

35562.600

44.58

-6.43

38.15

-15.85

3

37778.000

54.54

-2.80

51.74

-22.26

4

37778.000

43.64

-2.80

40.84

-13.16

5

39254.200

53.03

0.82

53.86

-20.14

6 * 39254.200

40.38

0.82

41.20

-12.80

Notes:

1. " * ", means this data is the worst emission level.

2. C.F (dB/m) = Antenna Factor (dB/m) + Cable Loss (dB) - AMP (dB).

3. Measurement(dBV/m) = Reading(dBV) + C.F (dB/m).

Limit (dBV/m)
74.00 54.00 74.00 54.00 74.00 54.00

Detector
Peak Average
Peak Average
Peak Average

65 of 73

Site Temperature Limit Factor EUT Test Mode

Report No.: 2408RSU020-U8

SIP-AC3 19.3C FCC_Part 15.209_RSE(3m)_QP VULB 9168_00997_25-2000MHz OmniAccess Stellar (OAW-AP1521) Mode 7

Test Date Humidity Test Engineer Polarity Test Voltage

2024-12-18 35.2% Fusco Pan Horizontal AC 120V/60Hz

Frequency No Mark
(MHz)

Reading (dBV)

C.F (dB/m)

Measurement (dBV/m)

1

163.468

11.04

18.17

29.21

2

199.986

12.96

15.11

28.07

3 *

250.038

18.28

17.02

35.31

4

300.052

12.99

18.70

31.68

5

393.748

10.18

20.80

30.98

6

750.108

-9.99

28.42

18.43

Notes:

1. " * ", means this data is the worst emission level.

2. C.F (dB/m) = Antenna Factor (dB/m) + Cable Loss (dB).

3. Measurement (dBV/m) = Reading (dBV) + C.F (dB/m).

Margin (dB) -14.29 -15.43 -10.69 -14.32 -15.02 -27.57

Limit (dBV/m)
43.50 43.50 46.00 46.00 46.00 46.00

Detector
QP QP QP QP QP QP

66 of 73

Site Temperature Limit Factor EUT Test Mode

Report No.: 2408RSU020-U8

SIP-AC3 19.3C FCC_Part 15.209_RSE(3m)_QP VULB 9168_00997_25-2000MHz OmniAccess Stellar (OAW-AP1521) Mode 7

Test Date Humidity Test Engineer Polarity Test Voltage

2024-12-18 35.2% Fusco Pan Vertical AC 120V/60Hz

Frequency No Mark
(MHz)

Reading (dBV)

C.F (dB/m)

Measurement (dBV/m)

1

37.932

11.10

17.79

28.89

2

58.020

11.30

18.28

29.58

3

79.800

15.80

14.25

30.05

4 *

173.814

18.91

17.50

36.41

5

250.038

19.51

17.02

36.53

6

394.716

11.57

20.81

32.38

Notes:

1. " * ", means this data is the worst emission level.

2. C.F (dB/m) = Antenna Factor (dB/m) + Cable Loss (dB).

3. Measurement (dBV/m) = Reading (dBV) + C.F (dB/m).

Margin (dB) -11.11 -10.42 -9.95 -7.09 -9.47 -13.62

Limit (dBV/m)
40.00 40.00 40.00 43.50 46.00 46.00

Detector
QP QP QP QP QP QP

67 of 73

Report No.: 2408RSU020-U8

Site Test Engineer Factor EUT Test Mode

SIP-AC3 Barry Wu HF907_102861_1-18GHz OmniAccess Stellar (OAW-AP1521) Mode 7

Test Date Temp./Humidity Polarity Test Voltage

2024-11-07 21.1C/51.5% Horizontal AC 120V/60Hz

Frequency No Mark
(MHz)

Reading (dBV)

C.F (dB/m)

Measurement (dBV/m)

Margin (dB)

1

9647.900

53.61

-1.55

52.05

-21.95

2 * 9647.900

50.38

-1.55

48.83

-5.17

3

14236.200

48.49

3.20

51.69

-22.31

4

14236.200

34.10

3.20

37.30

-16.70

5

17435.600

45.08

8.80

53.88

-20.12

6

17435.600

31.50

8.80

40.30

-13.70

Notes:

1. " * ", means this data is the worst emission level.

2. C.F (dB/m) = Antenna Factor (dB/m) + Cable Loss (dB) - AMP (dB).

3. Measurement(dBV/m) = Reading(dBV) + C.F (dB/m).

Limit (dBV/m)
74.00 54.00 74.00 54.00 74.00 54.00

Detector
Peak Average
Peak Average
Peak Average

68 of 73

Report No.: 2408RSU020-U8

Site Test Engineer Factor EUT Test Mode

SIP-AC3 Barry Wu HF907_102861_1-18GHz OmniAccess Stellar (OAW-AP1521) Mode 7

Test Date Temp./Humidity Polarity Test Voltage

2024-11-07 21.1C/51.5% Vertical AC 120V/60Hz

Frequency No Mark
(MHz)

Reading (dBV)

C.F (dB/m)

Measurement (dBV/m)

Margin (dB)

1

9647.900

53.26

-1.55

51.71

-22.29

2 * 9647.900

49.70

-1.55

48.15

-5.85

3

14006.700

46.78

3.64

50.43

-23.57

4

14006.700

34.20

3.64

37.84

-16.16

5

17541.000

45.12

9.01

54.13

-19.87

6

17541.000

31.30

9.01

40.31

-13.69

Notes:

1. " * ", means this data is the worst emission level.

2. C.F (dB/m) = Antenna Factor (dB/m) + Cable Loss (dB) - AMP (dB).

3. Measurement(dBV/m) = Reading(dBV) + C.F (dB/m).

Limit (dBV/m)
74.00 54.00 74.00 54.00 74.00 54.00

Detector
Peak Average
Peak Average
Peak Average

69 of 73

Report No.: 2408RSU020-U8

Site Test Engineer Factor EUT Test Mode

SIP-AC3 Mero Zhou BBHA 9170_00934_18-40GHz OmniAccess Stellar (OAW-AP1521) Mode 7

Test Date Temp./Humidity Polarity Test Voltage

2024-11-15 20.7C/62.4% Horizontal AC 120V/60Hz

Frequency No Mark
(MHz)

Reading (dBV)

C.F (dB/m)

Measurement (dBV/m)

Margin (dB)

1

30511.400

58.05

-8.36

49.69

-24.31

2

30511.400

45.33

-8.36

36.97

-17.03

3

37670.200

55.92

-3.66

52.26

-21.74

4

37670.200

42.03

-3.66

38.37

-15.63

5

39142.000

54.68

-1.09

53.59

-20.41

6 * 39142.000

41.57

-1.09

40.48

-13.52

Notes:

1. " * ", means this data is the worst emission level.

2. C.F (dB/m) = Antenna Factor (dB/m) + Cable Loss (dB) - AMP (dB).

3. Measurement(dBV/m) = Reading(dBV) + C.F (dB/m).

Limit (dBV/m)
74.00 54.00 74.00 54.00 74.00 54.00

Detector
Peak Average
Peak Average
Peak Average

70 of 73

Report No.: 2408RSU020-U8

Site Test Engineer Factor EUT Test Mode

SIP-AC3 Mero Zhou BBHA 9170_00934_18-40GHz OmniAccess Stellar (OAW-AP1521) Mode 7

Test Date Temp./Humidity Polarity Test Voltage

2024-11-15 20.7C/62.4% Vertical AC 120V/60Hz

Frequency No Mark
(MHz)

Reading (dBV)

C.F (dB/m)

Measurement (dBV/m)

Margin (dB)

1

35362.400

57.59

-6.91

50.69

-23.31

2

35362.400

44.58

-6.91

37.67

-16.33

3

37362.200

56.08

-3.69

52.38

-21.62

4

37362.200

43.38

-3.69

39.69

-14.31

5

39258.600

52.99

0.62

53.60

-20.40

6 * 39258.600

40.47

0.62

41.09

-12.91

Notes:

1. " * ", means this data is the worst emission level.

2. C.F (dB/m) = Antenna Factor (dB/m) + Cable Loss (dB) - AMP (dB).

3. Measurement(dBV/m) = Reading(dBV) + C.F (dB/m).

Limit (dBV/m)
74.00 54.00 74.00 54.00 74.00 54.00

Detector
Peak Average
Peak Average
Peak Average

71 of 73

Appendix A - Test Setup Photograph
Refer to "2408RSU020-UT" file.

Report No.: 2408RSU020-U8

72 of 73

Appendix B - EUT Photograph
Refer to "2408RSU020-UE" file.

Report No.: 2408RSU020-U8

The End 73 of 73



Related FCC IDs:

Search Any Device: