Measurement Report
Kent
RF Exposure
Shanghai Yibo Technology Co., LTD RPT2024 2BGEC-RPT2024 2BGECRPT2024 rpt2024
Not Your Device? Search For Manuals or Datasheets below:
File Info : application/pdf, 2 Pages, 126.12KB
Document DEVICE REPORTGetApplicationAttachment.html?id=7387639CTC Laboratories, Inc. $CNAS$ Room 101 Building B, No. 7, Lanqing 1st Road, Luhu Community, Guanhu Subdistrict, Longhua District, Shenzhen, Guangdong, China Tel: +86-755-27521059 Fax: +86-755-27521011 Http://www.sz-ctc.org.cn Maximum Permissible Exposure Evaluation FCC ID: 2BGEC-RPT2024 According to FCC 1.1310: The criteria listed in the following table shall be used to evaluate the environment impact of human exposure to radio frequency (RF) Radiation as specified in §1.1307(b) . EUT Specification Product Name: Broadcast Module Trade Mark: Model/Type Ref erence: Listed Model(s): EabloPilot EabloPilot Tag / Model Differences: / Frequency Band (Operating) BLE: 2402MHz ~ 2480MHz WLAN: 2412MHz ~ 2462MHz Device Category Portable (<5mm separation) Mobile (>20cm separation) Fixed (>20cm separation) Others ___ Exposure Classif ication Occupational/Controlled exposure (S=5mW/cm2) General Population/Uncontrolled exposure (S=1mW/cm2) Antenna Diversity Antenna Gain (Max) Evaluation Applied Single antenna Multiple antennas Tx diversity Rx diversity Tx/Rx diversity BT/ WLAN: 5.05dBi MPE Evaluation SAR Evaluation CTC Laboratories, Inc. Room 101 Building B, No. 7, Lanqing 1st Road, Luhu Community, Guanhu Subdistrict, Longhua District, Shenzhen, Guangdong, Chin a Tel.: (86)755-27521059 Fax: (86)755-27521011 Http://www.sz-ctc.org.cn For anti-fake verification, please visit the official website of Certification and Accreditation Administration of the People's Republic of China : yz.cnca.cn Page 2 of 2 Report No.: CTC2024098408 Limits for Maximum Permissible Exposure (MPE) Frequency Range (MHz) Electric Field Magnetic Field Strength (V/m) Strength (A/m) Power Density (mW/cm2) (A) Limits for Occupational/Controlled Exposure 300-1500 -- -- F/300 1500-100000 -- -- 5 (B) Limits for General Population/Uncontrolled Exposure 300-1500 -- -- F/1500 1500-100000 -- -- 1 Averaging Time (minutes) <6 <6 <30 <30 Calculation Method Friis transmission formula: Pd=(Pout*G)/(4*Pi*R2) Where: Pd= Power density in mW/cm2 Pout= output power to antenna in mW G= gain of antenna in linear scale Pi= 3.1416 R= distance between observation point and center of the radiator in cm Pd limit of MPE is 1mW/cm2. If we know the maximum gain of the antenna and total power input to the antenna, through the calculation, we will know the distance where the MPE limit is reached. Measurement Result Mode BLE 1M WLAN 11B Frequency (MHz) Antenna Gain (dBi) Maximu m Power (dBm) Tune Up Tolerance (dB) Max. Tune Up Power (dBm) Power Density at Limit 20cm (mW/cm2) (mW/cm2) Verdict 2402 5.05 9.89 ±1 10 0.00636 1 PASS 2412 5.05 16.45 ±1 17 0.03190 1 PASS The WLAN and BT can transmit simultaneously. WLAN Power density at 20cm (mW/cm2 ) BT Power density at 20cm (mW/cm2 ) Total Power density at 20cm (mW/cm2) 0.03190 0.00636 0.03826 Power density Limit (mW/cm2) 1 Verdict PASS Note: 1. Calculate in the worst-case mode. 2. Max. Tune Up Power is declared by manufacturer, and used to calculate. 3. For a more detailed features description, please refer to the RF Test Report. **********************THE END********************** CTC Laboratories, Inc. Room 101 Building B, No. 7, Lanqing 1st Road, Luhu Community, Guanhu Subdistrict, Longhua District, Shenzhen, Guangdong, Chin a Tel.: (86)755-27521059 Fax: (86)755-27521011 Http://www.sz-ctc.org.cn For anti-fake verification, please visit the official website of Certification and Accreditation Administration of the People's Republic of China : yz.cnca.cn
Related FCC IDs:
- 2BGEC-RPT2024 - Shanghai Yibo Technology Co., LTD Broadcast Module [-RPT2024] Microsoft Word 2021