Measurement Report

Kent

RF Exposure

Shanghai Yibo Technology Co., LTD RPT2024 2BGEC-RPT2024 2BGECRPT2024 rpt2024

PDF Viewing Options

Not Your Device? Search For Manuals or Datasheets below:


File Info : application/pdf, 2 Pages, 126.12KB

Document DEVICE REPORTGetApplicationAttachment.html?id=7387639
CTC Laboratories, Inc.

$CNAS$

Room 101 Building B, No. 7, Lanqing 1st Road, Luhu Community, Guanhu Subdistrict, Longhua District, Shenzhen, Guangdong, China
Tel: +86-755-27521059 Fax: +86-755-27521011 Http://www.sz-ctc.org.cn

Maximum Permissible Exposure Evaluation
FCC ID: 2BGEC-RPT2024

According to FCC 1.1310: The criteria listed in the following table shall be used to evaluate the environment impact of human exposure to radio frequency (RF) Radiation as specified in §1.1307(b) .

EUT Specification

Product Name:

Broadcast Module

Trade Mark:
Model/Type Ref erence:
Listed Model(s):

EabloPilot EabloPilot Tag /

Model Differences: /

Frequency Band (Operating)

BLE: 2402MHz ~ 2480MHz WLAN: 2412MHz ~ 2462MHz

Device Category

Portable (<5mm separation) Mobile (>20cm separation) Fixed (>20cm separation) Others ___

Exposure Classif ication

Occupational/Controlled exposure (S=5mW/cm2) General Population/Uncontrolled exposure (S=1mW/cm2)

Antenna Diversity
Antenna Gain (Max) Evaluation Applied

Single antenna Multiple antennas Tx diversity Rx diversity Tx/Rx diversity
BT/ WLAN: 5.05dBi
MPE Evaluation SAR Evaluation

CTC Laboratories, Inc. Room 101 Building B, No. 7, Lanqing 1st Road, Luhu Community, Guanhu Subdistrict, Longhua District, Shenzhen, Guangdong, Chin a
Tel.: (86)755-27521059 Fax: (86)755-27521011 Http://www.sz-ctc.org.cn For anti-fake verification, please visit the official website of Certification and Accreditation Administration of the People's Republic of China : yz.cnca.cn

Page 2 of 2

Report No.: CTC2024098408

Limits for Maximum Permissible Exposure (MPE)

Frequency Range (MHz)

Electric Field Magnetic Field Strength (V/m) Strength (A/m)

Power Density (mW/cm2)

(A) Limits for Occupational/Controlled Exposure

300-1500

--

--

F/300

1500-100000

--

--

5

(B) Limits for General Population/Uncontrolled Exposure

300-1500

--

--

F/1500

1500-100000

--

--

1

Averaging Time
(minutes)
<6 <6
<30 <30

Calculation Method
Friis transmission formula: Pd=(Pout*G)/(4*Pi*R2) Where: Pd= Power density in mW/cm2 Pout= output power to antenna in mW G= gain of antenna in linear scale Pi= 3.1416 R= distance between observation point and center of the radiator in cm
Pd limit of MPE is 1mW/cm2. If we know the maximum gain of the antenna and total power input to the antenna, through the calculation, we will know the distance where the MPE limit is reached.

Measurement Result

Mode
BLE 1M WLAN 11B

Frequency (MHz)

Antenna Gain (dBi)

Maximu m Power (dBm)

Tune Up Tolerance
(dB)

Max. Tune Up
Power (dBm)

Power Density at Limit
20cm (mW/cm2) (mW/cm2)

Verdict

2402 5.05 9.89

±1

10 0.00636

1

PASS

2412 5.05 16.45 ±1

17 0.03190

1

PASS

The WLAN and BT can transmit simultaneously.

WLAN Power density at
20cm (mW/cm2 )

BT Power density at
20cm (mW/cm2 )

Total Power density at
20cm (mW/cm2)

0.03190

0.00636

0.03826

Power density Limit
(mW/cm2)
1

Verdict PASS

Note: 1. Calculate in the worst-case mode. 2. Max. Tune Up Power is declared by manufacturer, and used to calculate. 3. For a more detailed features description, please refer to the RF Test Report.