Sam Lin
CN22SYO5 001 15B Impacta 220
Intelbras Industria de Telecomunicacao Eletronica Brasileira IMPACTA220 Impacta 220 2A76R-IMPACTA220 2A76RIMPACTA220 impacta220
Not Your Device? Search For Manuals or Datasheets below:
File Info : application/pdf, 18 Pages, 1.24MB
Document DEVICE REPORTGetApplicationAttachment.html?id=6100616Prüfbericht - Produkte Test Report - Products Prüfbericht-Nr.: Test report no.: Kunden-Referenz-Nr.: Client reference no.: Auftraggeber: Client: Prüfgegenstand: Test item: Bezeichnung / Typ-Nr.: Identification / Type no.: Auftrags-Inhalt: Order content: Prüfgrundlage: Test specification: CN22SYO5 001 Auftrags-Nr.: Order no.: 168374467 N/A Auftragsdatum: 2022-05-26 Order date: Intelbras Industria de Telecomunicacao Eletronica Brasileira Rodovia BR 101 KM 210 Area Industrial Sao Jose Brazil Impacta exchanges Impacta 220 Test Report FCC CFR Title 47, Part 15, Subpart B Seite 1 von 18 Page 1 of 18 Wareneingangsdatum: 2022-06-27 Date of sample receipt: Prüfmuster-Nr.: Test sample no: A003285007-001 A003285010-001 A003285800-001~013 Prüfzeitraum: Testing period: 2022-07-14 2022-08-03 Please refer to Photo Document Ort der Prüfung: Place of testing: TÜV Rheinland (Shenzhen) Co., Ltd. Prüflaboratorium: Testing laboratory: TÜV Rheinland (Shenzhen) Co., Ltd. Prüfergebnis*: Test result*: Pass geprüft von: tested by: Datum: Date: 2022-08-30 Stellung / Position: Sonstiges / Other: X Signed by: Bell Hu Project Manager FCC ID: 2A76R-IMPACTA220 genehmigt von: authorized by: Ausstellungsdatum: Issue date: 2022-08-30 X Signed by: Lin Lin Stellung / Position: Reviewer Zustand des Prüfgegenstandes bei Anlieferung: Condition of the test item at delivery: Prüfmuster vollständig und unbeschädigt Test item complete and undamaged * Legende: * Legend: 1 = sehr gut 2 = gut P(ass) = entspricht o.g. Prüfgrundlage(n) 1 = very good 2 = good P(ass) = passed a.m. test specification(s) 3 = befriedigend F(ail) = entspricht nicht o.g. Prüfgrundlage(n) 3 = satisfactory F(ail) = failed a.m. test specification(s) 4 = ausreichend N/A = nicht anwendbar 4 = sufficient N/A = not applicable 5 = mangelhaft N/T = nicht getestet 5 = poor N/T = not tested Dieser Prüfbericht bezieht sich nur auf das o.g. Prüfmuster und darf ohne Genehmigung der Prüfstelle nicht auszugsweise vervielfältigt werden. Dieser Bericht berechtigt nicht zur Verwendung eines Prüfzeichens. This test report only relates to the a. m. test sample. Without permission of the test center this test report is not permitted to be duplicated in extracts. This test report does not entitle to carry any test mark. TÜV Rheinland (Shenzhen) Co., Ltd. 1601 R&D Room, 1602-1604, 17-18F, Building 7 Site C, Vanke Cloud City Phase I, Xingke First Street, Xili Street, Xili Community, Nanshan District, Shenzhen 518052, P.R. China Mail: [email protected] ·Web: www.tuv.com jjj Prüfbericht - Produkte Test Report - Products Prüfbericht - Nr.: Test Report No.: CN22SYO5 001 Test Summary 5.1.1 CONDUCTED EMISSION ON AC MAINS RESULT: Pass 5.1.2 RADIATED EMISSIONS RESULT: Pass Seite 2 von 18 Page 2 of 18 Prüfbericht - Produkte Test Report - Products Prüfbericht - Nr.: Test Report No.: CN22SYO5 001 Seite 3 von 18 Page 3 of 18 Table of Contents 1 GENERAL REMARKS ...........................................................................................................................4 1.1 COMPLEMENTARY MATERIALS ............................................................................................................4 2 TEST SITES ........................................................................................................................................5 2.1 TEST FACILITIES .................................................................................................................................5 2.2 LIST OF TEST AND MEASUREMENT INSTRUMENTS.................................................................................5 2.3 TRACEABILITY ....................................................................................................................................5 2.4 CALIBRATION .....................................................................................................................................5 2.5 MEASUREMENT UNCERTAINTY.............................................................................................................6 2.6 LOCATION OF ORIGINAL DATA.............................................................................................................6 2.7 STATUS OF FACILITY USED FOR TESTING.............................................................................................6 3 GENERAL PRODUCT INFORMATION ......................................................................................................7 3.1 PRODUCT FUNCTION AND INTENDED USE.............................................................................................7 3.2 RATINGS AND SYSTEM DETAILS ..........................................................................................................7 3.3 INDEPENDENT OPERATION MODES ......................................................................................................7 3.4 NOISE GENERATING AND NOISE SUPPRESSING PARTS .........................................................................7 3.5 SUBMITTED DOCUMENTS.....................................................................................................................7 4 TEST SET-UP AND OPERATION MODES ................................................................................................8 4.1 PRINCIPLE OF CONFIGURATION SELECTION .........................................................................................8 4.2 TEST OPERATION AND TEST SOFTWARE ..............................................................................................8 4.3 SPECIAL ACCESSORIES AND AUXILIARY EQUIPMENT ............................................................................8 4.4 COUNTERMEASURES TO ACHIEVE EMC COMPLIANCE ..........................................................................8 4.5 TEST SETUP DIAGRAM ........................................................................................................................9 5 TEST RESULTS .................................................................................................................................10 5.1.1 Conducted Emission on AC Mains.............................................................................................10 5.1.2 Radiated Emissions....................................................................................................................13 6 PHOTOGRAPHS OF THE TEST SET-UP ................................................................................................18 7 LIST OF TABLES................................................................................................................................18 Prüfbericht - Produkte Test Report - Products Prüfbericht - Nr.: CN22SYO5 001 Test Report No.: 1 General Remarks Seite 4 von 18 Page 4 of 18 1.1 Complementary Materials All attachments are integral parts of this test report. This applies especially to the following appendix: Appendix A: Photographs of the Test Set-up Prüfbericht - Produkte Test Report - Products Prüfbericht - Nr.: Test Report No.: 2 Test Sites CN22SYO5 001 Seite 5 von 18 Page 5 of 18 2.1 Test Facilities TÜV Rheinland (Shenzhen) Co., Ltd. 362 Huanguan Road Middle Longhua District, Shenzhen 518110 People's Republic of China FCC Accreditation Designation No.: CN1260 2.2 List of Test and Measurement Instruments Table 1: List of Test and Measurement Equipment Conducted Emission Equipment Manufacturer EMI Test Receiver R&S Artificial Mains Network Artificial Mains Network R&S R&S EMC32 test software R&S Radiated Emission (3m chamber) Equipment Manufacturer 3m SAC ETS-Lindgren EMI Test Receiver R&S Horn Antenna R&S Preamplifier (1-18GHz) Trilog-Broadband antenna FIT SCHWARZBECK EMC32 test software R&S Model No. ESR3 ENV216 ENV432 EMC32(Ver.10.50.00) Model No. SAC3 ESR7 HF907 SCU-18F VULB9168 EMC32(Ver.10.50.00) Serial No. 102680 101445 101546 N/A Serial No. CT001632-Q1362 102111 102706 180077 0945 N/A Cal. Until 2023-02-27 2023-02-27 2023-02-27 N/A Cal. Until 2024-04-26 2022-12-01 2022-08-07 2022-08-13 2022-12-12 N/A 2.3 Traceability All measurement equipment calibrations are traceable to NIM (National Institute of Metrology) or where calibration is performed in other countries, to equivalent nationally recognized standards organizations. 2.4 Calibration Equipment requiring calibration is calibrated periodically by the manufacturer or according to manufacturer's specifications. Additionally all equipment is verified for proper performance on a regular basics using in house standards or comparisons. Prüfbericht - Produkte Test Report - Products Prüfbericht - Nr.: CN22SYO5 001 Test Report No.: Seite 6 von 18 Page 6 of 18 2.5 Measurement Uncertainty The estimated combined standard uncertainty for radiated emissions and conducted emissions measurements as below table. Parameter Radiated Emission (3m SAC), 30MHz to 1000MHz Radiated Emission (3m SAC), above 1000MHz Conducted Emission, (9kHz to 150kHz)/(150kHz to 30MHz) Uncertainty ± 4.52 dB ± 4.37 dB ± 3.70 dB / ± 3.30 dB 2.6 Location of Original Data The original copies of all test data taken during actual testing were attached at Appendix A of this report and delivered to the applicant. A copy has been retained in the TÜV Rheinland (Shenzhen) Co., Ltd. file for certification follow-up purposes. 2.7 Status of Facility Used for Testing The TÜV Rheinland (Shenzhen) Co., Ltd. Test facility located at 362 Huanguan Road Middle Longhua District, Shenzhen 518110 People's Republic of China is listed on the US Federal Communications Commission list of facilities approved to perform measurements. Prüfbericht - Produkte Test Report - Products Prüfbericht - Nr.: CN22SYO5 001 Test Report No.: 3 General Product Information 3.1 Product Function and Intended Use The EUT is an Impacta exchanges. For details refer to the User Manual, Technical Description and Circuit Diagram. 3.2 Ratings and System Details Table 2: Technical Specification of EUT General Information of EUT Kind of Equipment: Type Designation: FCC ID: Operating Voltage: Operating Temperature Range: Equipement Class: Value Impacta exchanges Impacta 220 2A76R-IMPACTA220 AC 120V, 60Hz 0 °C ~ +45 °C Class A digital device (JAD) Seite 7 von 18 Page 7 of 18 3.3 Independent Operation Modes The basic operation modes are: A. On, Normal working B. Off 3.4 Noise Generating and Noise Suppressing Parts Refer to Circuit Diagram for further details. 3.5 Submitted Documents - User Manual - ID Label and Location Info - Schematics - Operation Description - Block Diagram - PCB Layout Prüfbericht - Produkte Test Report - Products Prüfbericht - Nr.: CN22SYO5 001 Test Report No.: 4 Test Set-up and Operation Modes Seite 8 von 18 Page 8 of 18 4.1 Principle of Configuration Selection Emission: The equipment under test (EUT) was configured to measure its highest possible radiation level. The test modes were adapted accordingly in reference to the instructions for use. 4.2 Test Operation and Test Software Test operation refers to test setup in chapter 5. All tests were performed according to the procedures in ANSI C63.4: 2014. According to clause 3.1, all tests were performed on model Impacta 220 in this report. 4.3 Special Accessories and Auxiliary Equipment Table 3: Auxiliary Equipment Used during Test Description Manufacturer Model Smart terminal Intelbras TI5000 S/N Remark N/A Connecting with Impacta 220 4.4 Countermeasures to Achieve EMC Compliance The test sample which has been tested contained the noise suppression parts as described in the Technical Construction File (TCF). No additional measures were employed to achieve compliance. Prüfbericht - Produkte Test Report - Products Prüfbericht - Nr.: Test Report No.: CN22SYO5 001 4.5 Test Setup Diagram Diagram of Measurement Configuration for Radiation Test (Below 1GHz) Seite 9 von 18 Page 9 of 18 Diagram of Measurement Configuration for Radiation Test (Above 1GHz) Diagram of Measurement Configuration for Mains Conduction Measurement Prüfbericht - Produkte Test Report - Products Prüfbericht - Nr.: CN22SYO5 001 Test Report No.: 5 Test Results 5.1.1 Conducted Emission on AC Mains RESULT: Test Specification Test standard Basic standard Frequency range Classification Limits Kind of test site : FCC Part 15.107(a) : ANSI C63.4:2014 : 0.15 30MHz : Class A : FCC Part 15.107(a) : Shielded Room Test Setup Date of testing Input voltage Operation mode Ambient temperature Relative humidity Atmospheric pressure : 2022-07-14 : AC 120V, 60Hz : A : 24.1 : 52.8 % : 101 kPa For the measurement records, refer to the following plots. Seite 10 von 18 Page 10 of 18 Pass Prüfbericht - Produkte Test Report - Products Prüfbericht - Nr.: Test Report No.: CN22SYO5 001 EUT Information EUT Name: Order No: Model: Test mode: Test Voltage: Test By:/Review By: Test Standard: Tem./Hum./Pressure: Remark: Impacta exchanges 168374467 Impacta 220 ON, Normal working AC 120V/50Hz Kevin Zhou/Gary Chen FCC Part 15B 24.1°C/52.8%//101kPa SR2 Seite 11 von 18 Page 11 of 18 Level in dB Critical_Freqs Frequency (MHz) MaxPeak (dBµV) 0.162000 0.162000 48.88 --- 6.178500 6.234500 57.99 --- 6.698500 6.777500 7.282500 --60.82 --- 7.285500 10.394000 10.526000 63.19 52.49 --- 14.050000 14.214000 52.74 --- Average (dBµV) --42.51 --36.28 40.92 --41.48 ----40.14 --41.89 Limit (dBµV) 65.36 55.36 60.00 50.00 50.00 60.00 50.00 60.00 60.00 50.00 60.00 50.00 Margin (dB) 16.48 12.85 2.01 13.72 9.08 -0.82 8.52 -3.19 7.51 9.86 7.26 8.11 Line L1 L1 L1 L1 L1 L1 L1 L1 L1 L1 L1 L1 Corr. (dB) 9.9 9.9 10.3 10.3 10.3 10.3 10.3 10.3 10.3 10.3 10.4 10.4 Final_Result Frequency (MHz) QuasiPeak (dBµV) 6.178500 49.52 6.234500 --- 6.698500 --- 6.777500 54.27 7.282500 --- 7.285500 55.97 Average (dBµV) --32.83 36.63 --39.04 --- Limit (dBµV) 60.00 50.00 50.00 60.00 50.00 60.00 Margin (dB) 10.48 17.17 13.37 5.73 10.96 4.03 Meas. Time (ms) 3000.0 3000.0 3000.0 3000.0 3000.0 3000.0 Bandwidth (kHz) 9.000 9.000 9.000 9.000 9.000 9.000 Line L1 L1 L1 L1 L1 L1 Corr. (dB) 10.3 10.3 10.3 10.3 10.3 10.3 Prüfbericht - Produkte Test Report - Products Prüfbericht - Nr.: Test Report No.: CN22SYO5 001 EUT Information EUT Name: Order No: Model: Test mode: Test Voltage: Test By:/Review By: Test Standard: Tem./Hum./Pressure: Remark: Impacta exchanges 168374467 Impacta 220 ON, Normal working AC 120V/50Hz Kevin Zhou/Gary Chen FCC Part 15B 24.1°C/52.8%//101kPa SR2 Seite 12 von 18 Page 12 of 18 Level in dB Critical_Freqs Frequency (MHz) MaxPeak (dBµV) 0.162000 48.68 0.162000 --- 0.270000 39.90 0.274000 34.62 6.077500 --- 6.098500 57.87 6.622500 60.06 6.690500 --- 7.169500 --- 7.178500 61.91 14.274000 51.82 14.274000 --- Average (dBµV) --39.58 ----36.55 ----39.03 41.74 ----41.10 Limit (dBµV) 65.36 55.36 61.12 61.00 50.00 60.00 60.00 50.00 50.00 60.00 60.00 50.00 Margin (dB) 16.68 15.78 21.22 26.38 13.45 2.13 -0.06 10.97 8.26 -1.91 8.18 8.90 Line N N N N N N N N N N N N Corr. (dB) 9.8 9.8 9.8 9.8 9.9 9.9 10.0 10.0 10.0 10.0 10.1 10.1 Final_Result Frequency (MHz) QuasiPeak (dBµV) 6.077500 --- 6.098500 49.75 6.622500 54.56 6.690500 --- 7.169500 --- 7.178500 55.28 Average (dBµV) 34.07 ----- 36.91 38.73 --- Limit (dBµV) 50.00 60.00 60.00 50.00 50.00 60.00 Margin (dB) 15.93 10.25 5.44 13.09 11.27 4.72 Meas. Time (ms) 3000.0 3000.0 3000.0 3000.0 3000.0 3000.0 Bandwidth (kHz) 9.000 9.000 9.000 9.000 9.000 9.000 Line N N N N N N Corr. (dB) 9.9 9.9 10.0 10.0 10.0 10.0 Prüfbericht - Produkte Test Report - Products Prüfbericht - Nr.: CN22SYO5 001 Test Report No.: Seite 13 von 18 Page 13 of 18 5.1.2 Radiated Emissions RESULT: Pass Test Specification Test standard Basic standard Frequency range Classification Limits Kind of test site : FCC Part 15.109(a) : ANSI C63.4:2014 : 30MHz to 5th harmonic of the highest frequency : Class A : FCC Part 15.109(a) : 3m Semi-anechoic Chamber Test Setup Date of testing Input voltage Operation mode Ambient temperature Relative humidity Atmospheric pressure : 2022-07-26 to 2022-08-03 : AC 120V, 60Hz : A : Refer to test result : Refer to test result : 101 kPa For the measurement records, refer to the following plots. As for above 6GHz, only the noise-floors, thus no record for it. Prüfbericht - Produkte Test Report - Products Prüfbericht - Nr.: Test Report No.: CN22SYO5 001 EUT Information EUT Name: Order No: Model: Test Mode: Test Voltage: Standard: Test By:/Review By: Tem./Hum./Pressure: Remark: Impacta exchanges 168374467 30 Impacta 220 ON, Normal working AC 120V/60Hz FCC Part 15B Kevin Zhou/Gary Chen 24.1°C/50.8%/101kPa 3m chamber Seite 14 von 18 Page 14 of 18 Level in dB/m Critical_Freqs Frequency (MHz) MaxPeak Limit Margin Height Pol (dBµV/m) (dBµV/m) (dB) (cm) 99.840000 182.872000 39.46 42.20 53.50 53.50 14.04 11.30 200.0 H 200.0 H 266.583000 399.861000 38.28 44.11 56.00 56.00 17.72 11.89 100.0 H 100.0 H 739.361000 817.135000 44.81 47.09 56.00 56.00 11.19 8.91 100.0 H 100.0 H Azimuth (deg) 203.0 51.0 192.0 350.0 334.0 326.0 Corr. (dB/m) 17.1 18.7 20.4 23.3 30.2 30.5 Final_Result Frequency (MHz) QuasiPea k (dBµV/m) 817.135000 44.97 Limit (dBµV/m ) 56.00 Margin (dB) 11.03 Meas. Time (ms) Bandwid Height Pol th (cm) (kHz) 1000.0 120.000 100.0 H Azimuth Corr. (deg) (dB/m) 326.0 30.5 Prüfbericht - Produkte Test Report - Products Prüfbericht - Nr.: Test Report No.: CN22SYO5 001 EUT Information EUT Name: Order No: Model: Test Mode: Test Voltage: Standard: Test By:/Review By: Tem./Hum./Pressure: Remark: Impacta exchanges 168374467 30 Impacta 220 ON, Normal working AC 120V/60Hz FCC Part 15B Kevin Zhou/Gary Chen 24.1°C/50.8%/101kPa 3m chamber Seite 15 von 18 Page 15 of 18 Level in dB/m Critical_Freqs Frequency (MHz) MaxPeak Limit Margin Height Pol (dBµV/m) (dBµV/m) (dB) (cm) 180.738000 40.27 53.50 13.23 200.0 V 399.958000 43.53 56.00 12.47 200.0 V 488.810000 43.07 56.00 12.93 100.0 V 533.236000 42.38 56.00 13.62 200.0 V 817.155000 43.69 56.00 12.31 100.0 V 933.147000 45.76 56.00 10.24 100.0 V Azimuth (deg) 130.0 136.0 218.0 115.0 184.0 141.0 Corr. (dB/m) 19.2 23.3 24.9 25.3 30.5 32.1 Final_Result Frequency (MHz) QuasiPea k (dBµV/m) 933.147000 44.04 Limit (dBµV/m ) 56.00 Margin (dB) 11.96 Meas. Time (ms) Bandwid Height Pol th (cm) (kHz) 1000.0 120.000 100.0 V Azimuth Corr. (deg) (dB/m) 141.0 32.1 Prüfbericht - Produkte Test Report - Products Prüfbericht - Nr.: Test Report No.: CN22SYO5 001 EUT Information EUT Name: Order No: Model: Test Mode: Test Voltage: Standard: Test By:/Review By: Tem./Hum./Pressure: Remark: Impacta exchanges 168374467 30 Impacta 220 ON, Normal working AC 120V/60Hz FCC Part 15B Kevin Zhou/Gary Chen 24.1°C/51.3%/101kPa 3m chamber Seite 16 von 18 Page 16 of 18 Level in dB/m Critical_Freqs Frequency (MHz) MaxPeak Average Limit Margin Height Pol (dBµV/m) (dBµV/m) (dBµV/m) (dB) (cm) 1050.500000 39.86 --- 79.50 39.64 100.0 H 1050.500000 --- 37.80 59.50 21.70 100.0 H 1128.500000 40.86 --- 79.50 38.64 100.0 H 1128.500000 --- 40.46 59.50 19.04 100.0 H 1206.500000 35.66 --- 79.50 43.84 100.0 H 1206.500000 --- 35.06 59.50 24.44 100.0 H 1284.500000 36.95 --- 79.50 42.55 100.0 H 1284.500000 --- 35.24 59.50 24.26 100.0 H 3829.000000 43.14 --- 79.50 36.36 100.0 H 3829.000000 --- 41.50 59.50 18.00 100.0 H 4358.000000 44.97 --- 79.50 34.53 100.0 H 4358.000000 --- 42.40 59.50 17.10 100.0 H Azimuth (deg) 150.0 150.0 155.0 155.0 230.0 230.0 139.0 139.0 132.0 132.0 343.0 343.0 Corr. (dB/m) -13.2 -13.2 -13.1 -13.1 -14.0 -14.0 -14.0 -14.0 0.0 0.0 2.1 2.1 Prüfbericht - Produkte Test Report - Products Prüfbericht - Nr.: Test Report No.: CN22SYO5 001 EUT Information EUT Name: Order No: Model: Test Mode: Test Voltage: Standard: Test By:/Review By: Tem./Hum./Pressure: Remark: Impacta exchanges 168374467 30 Impacta 220 ON, Normal working AC 120V/60Hz FCC Part 15B Kevin Zhou/Gary Chen 24.1°C/51.3%/101kPa 3m chamber Seite 17 von 18 Page 17 of 18 Level in dB/m Critical_Freqs Frequency (MHz) MaxPeak Average Limit Margin Height Pol (dBµV/m) (dBµV/m) (dBµV/m) (dB) (cm) 1050.500000 --- 38.67 59.50 20.83 100.0 V 1051.000000 38.97 --- 79.50 40.53 100.0 V 1128.500000 39.78 --- 79.50 39.72 100.0 V 1128.500000 --- 39.30 59.50 20.20 100.0 V 1206.500000 39.69 --- 79.50 39.81 100.0 V 1206.500000 --- 38.93 59.50 20.57 100.0 V 1284.500000 36.60 --- 79.50 42.90 100.0 V 1284.500000 --- 35.02 59.50 24.48 100.0 V 1440.000000 37.58 --- 79.50 41.92 100.0 V 1440.000000 --- 36.41 59.50 23.09 100.0 V 1517.500000 38.22 --- 79.50 41.28 100.0 V 1517.500000 --- 37.12 59.50 22.38 100.0 V Azimuth (deg) 270.0 120.0 252.0 252.0 274.0 274.0 194.0 194.0 297.0 297.0 304.0 304.0 Corr. (dB/m) -13.2 -13.2 -13.1 -13.1 -14.0 -14.0 -14.0 -14.0 -12.6 -12.6 -11.0 -11.0 Prüfbericht - Produkte Test Report - Products Prüfbericht - Nr.: Test Report No.: CN22SYO5 001 6 Photographs of the Test Set-Up For photographs of the test set-up, refer to the appendix A. Seite 18 von 18 Page 18 of 18 7 List of Tables Table 1: List of Test and Measurement Equipment..................................................................... 5 Table 2: Technical Specification of EUT ..................................................................................... 7 Table 3: Auxiliary Equipment Used during Test .......................................................................... 8
Related FCC IDs:
- 2A76R-IMPACTA220 - Intelbras Industria de Telecomunicacao Eletronica Brasileira Impacta 220 [-IMPACTA220] Microsoft Word 2016; modified using iText 4.2.2 by 1T3XT, AuthentiDate