Prüfbericht - Produkte Test Report - Products
Prüfbericht-Nr.: Test report no.:
Kunden-Referenz-Nr.: Client reference no.:
Auftraggeber: Client:
Prüfgegenstand: Test item:
Bezeichnung / Typ-Nr.: Identification / Type no.:
Auftrags-Inhalt: Order content:
Prüfgrundlage: Test specification:

CN22SYO5 001

Auftrags-Nr.: Order no.:

168374467

N/A

Auftragsdatum: 2022-05-26

Order date:

Intelbras Industria de Telecomunicacao Eletronica Brasileira Rodovia BR 101 KM 210 Area Industrial Sao Jose Brazil

Impacta exchanges

Impacta 220

Test Report

FCC CFR Title 47, Part 15, Subpart B

Seite 1 von 18 Page 1 of 18

Wareneingangsdatum: 2022-06-27 Date of sample receipt:

Prüfmuster-Nr.: Test sample no:

A003285007-001 A003285010-001 A003285800-001~013

Prüfzeitraum: Testing period:

2022-07-14 ­ 2022-08-03

Please refer to Photo Document

Ort der Prüfung: Place of testing:

TÜV Rheinland (Shenzhen) Co., Ltd.

Prüflaboratorium: Testing laboratory:

TÜV Rheinland (Shenzhen) Co., Ltd.

Prüfergebnis*: Test result*:

Pass

geprüft von: tested by:
Datum: Date: 2022-08-30 Stellung / Position:
Sonstiges / Other:

X
Signed by: Bell Hu
Project Manager FCC ID: 2A76R-IMPACTA220

genehmigt von: authorized by:
Ausstellungsdatum: Issue date: 2022-08-30

X
Signed by: Lin Lin

Stellung / Position:

Reviewer

Zustand des Prüfgegenstandes bei Anlieferung: Condition of the test item at delivery:

Prüfmuster vollständig und unbeschädigt Test item complete and undamaged

* Legende: * Legend:

1 = sehr gut

2 = gut

P(ass) = entspricht o.g. Prüfgrundlage(n)

1 = very good

2 = good

P(ass) = passed a.m. test specification(s)

3 = befriedigend F(ail) = entspricht nicht o.g. Prüfgrundlage(n)
3 = satisfactory F(ail) = failed a.m. test specification(s)

4 = ausreichend
N/A = nicht anwendbar 4 = sufficient N/A = not applicable

5 = mangelhaft
N/T = nicht getestet 5 = poor N/T = not tested

Dieser Prüfbericht bezieht sich nur auf das o.g. Prüfmuster und darf ohne Genehmigung der Prüfstelle nicht auszugsweise vervielfältigt werden. Dieser Bericht berechtigt nicht zur Verwendung eines Prüfzeichens.
This test report only relates to the a. m. test sample. Without permission of the test center this test report is not permitted to be duplicated in extracts. This test report does not entitle to carry any test mark.

TÜV Rheinland (Shenzhen) Co., Ltd. 1601 R&D Room, 1602-1604, 17-18F, Building 7 Site C, Vanke Cloud City Phase I, Xingke First Street, Xili Street, Xili Community, Nanshan District, Shenzhen 518052, P.R. China Mail: [email protected] ·Web: www.tuv.com
jjj

Prüfbericht - Produkte Test Report - Products
Prüfbericht - Nr.:
Test Report No.:

CN22SYO5 001

Test Summary
5.1.1 CONDUCTED EMISSION ON AC MAINS RESULT: Pass
5.1.2 RADIATED EMISSIONS RESULT: Pass

Seite 2 von 18 Page 2 of 18

Prüfbericht - Produkte Test Report - Products
Prüfbericht - Nr.:
Test Report No.:

CN22SYO5 001

Seite 3 von 18 Page 3 of 18

Table of Contents

1

GENERAL REMARKS ...........................................................................................................................4

1.1 COMPLEMENTARY MATERIALS ............................................................................................................4

2

TEST SITES ........................................................................................................................................5

2.1 TEST FACILITIES .................................................................................................................................5

2.2 LIST OF TEST AND MEASUREMENT INSTRUMENTS.................................................................................5

2.3 TRACEABILITY ....................................................................................................................................5

2.4 CALIBRATION .....................................................................................................................................5

2.5 MEASUREMENT UNCERTAINTY.............................................................................................................6

2.6 LOCATION OF ORIGINAL DATA.............................................................................................................6

2.7 STATUS OF FACILITY USED FOR TESTING.............................................................................................6

3

GENERAL PRODUCT INFORMATION ......................................................................................................7

3.1 PRODUCT FUNCTION AND INTENDED USE.............................................................................................7

3.2 RATINGS AND SYSTEM DETAILS ..........................................................................................................7

3.3 INDEPENDENT OPERATION MODES ......................................................................................................7

3.4 NOISE GENERATING AND NOISE SUPPRESSING PARTS .........................................................................7

3.5 SUBMITTED DOCUMENTS.....................................................................................................................7

4

TEST SET-UP AND OPERATION MODES ................................................................................................8

4.1 PRINCIPLE OF CONFIGURATION SELECTION .........................................................................................8

4.2 TEST OPERATION AND TEST SOFTWARE ..............................................................................................8

4.3 SPECIAL ACCESSORIES AND AUXILIARY EQUIPMENT ............................................................................8

4.4 COUNTERMEASURES TO ACHIEVE EMC COMPLIANCE ..........................................................................8

4.5 TEST SETUP DIAGRAM ........................................................................................................................9

5

TEST RESULTS .................................................................................................................................10

5.1.1 Conducted Emission on AC Mains.............................................................................................10

5.1.2 Radiated Emissions....................................................................................................................13

6

PHOTOGRAPHS OF THE TEST SET-UP ................................................................................................18

7

LIST OF TABLES................................................................................................................................18

Prüfbericht - Produkte Test Report - Products
Prüfbericht - Nr.: CN22SYO5 001
Test Report No.:
1 General Remarks

Seite 4 von 18 Page 4 of 18

1.1 Complementary Materials
All attachments are integral parts of this test report. This applies especially to the following appendix: Appendix A: Photographs of the Test Set-up

Prüfbericht - Produkte Test Report - Products
Prüfbericht - Nr.:
Test Report No.:
2 Test Sites

CN22SYO5 001

Seite 5 von 18 Page 5 of 18

2.1 Test Facilities
TÜV Rheinland (Shenzhen) Co., Ltd. 362 Huanguan Road Middle Longhua District, Shenzhen 518110 People's Republic of China
FCC Accreditation Designation No.: CN1260

2.2 List of Test and Measurement Instruments

Table 1: List of Test and Measurement Equipment

Conducted Emission

Equipment

Manufacturer

EMI Test Receiver

R&S

Artificial Mains Network
Artificial Mains Network

R&S R&S

EMC32 test software

R&S

Radiated Emission (3m chamber)

Equipment

Manufacturer

3m SAC

ETS-Lindgren

EMI Test Receiver

R&S

Horn Antenna

R&S

Preamplifier (1-18GHz)
Trilog-Broadband antenna

FIT SCHWARZBECK

EMC32 test software

R&S

Model No. ESR3
ENV216
ENV432 EMC32(Ver.10.50.00)
Model No. SAC3 ESR7 HF907
SCU-18F
VULB9168 EMC32(Ver.10.50.00)

Serial No. 102680 101445
101546 N/A
Serial No. CT001632-Q1362
102111 102706 180077
0945 N/A

Cal. Until 2023-02-27 2023-02-27
2023-02-27 N/A
Cal. Until 2024-04-26 2022-12-01 2022-08-07 2022-08-13
2022-12-12 N/A

2.3 Traceability
All measurement equipment calibrations are traceable to NIM (National Institute of Metrology) or where calibration is performed in other countries, to equivalent nationally recognized standards organizations.
2.4 Calibration
Equipment requiring calibration is calibrated periodically by the manufacturer or according to manufacturer's specifications. Additionally all equipment is verified for proper performance on a regular basics using in house standards or comparisons.

Prüfbericht - Produkte Test Report - Products

Prüfbericht - Nr.: CN22SYO5 001
Test Report No.:

Seite 6 von 18 Page 6 of 18

2.5 Measurement Uncertainty
The estimated combined standard uncertainty for radiated emissions and conducted emissions measurements as below table.

Parameter Radiated Emission (3m SAC), 30MHz to 1000MHz Radiated Emission (3m SAC), above 1000MHz Conducted Emission, (9kHz to 150kHz)/(150kHz to 30MHz)

Uncertainty ± 4.52 dB ± 4.37 dB
± 3.70 dB / ± 3.30 dB

2.6 Location of Original Data
The original copies of all test data taken during actual testing were attached at Appendix A of this report and delivered to the applicant. A copy has been retained in the TÜV Rheinland (Shenzhen) Co., Ltd. file for certification follow-up purposes.
2.7 Status of Facility Used for Testing
The TÜV Rheinland (Shenzhen) Co., Ltd. Test facility located at 362 Huanguan Road Middle Longhua District, Shenzhen 518110 People's Republic of China is listed on the US Federal Communications Commission list of facilities approved to perform measurements.

Prüfbericht - Produkte Test Report - Products
Prüfbericht - Nr.: CN22SYO5 001
Test Report No.:
3 General Product Information

3.1 Product Function and Intended Use
The EUT is an Impacta exchanges. For details refer to the User Manual, Technical Description and Circuit Diagram.

3.2 Ratings and System Details

Table 2: Technical Specification of EUT

General Information of EUT Kind of Equipment: Type Designation: FCC ID: Operating Voltage: Operating Temperature Range: Equipement Class:

Value Impacta exchanges Impacta 220 2A76R-IMPACTA220 AC 120V, 60Hz 0 °C ~ +45 °C Class A digital device (JAD)

Seite 7 von 18 Page 7 of 18

3.3 Independent Operation Modes
The basic operation modes are: A. On, Normal working B. Off

3.4 Noise Generating and Noise Suppressing Parts
Refer to Circuit Diagram for further details.

3.5 Submitted Documents
- User Manual - ID Label and Location Info - Schematics

- Operation Description - Block Diagram - PCB Layout

Prüfbericht - Produkte Test Report - Products
Prüfbericht - Nr.: CN22SYO5 001
Test Report No.:
4 Test Set-up and Operation Modes

Seite 8 von 18 Page 8 of 18

4.1 Principle of Configuration Selection
Emission: The equipment under test (EUT) was configured to measure its highest possible radiation level. The test modes were adapted accordingly in reference to the instructions for use.
4.2 Test Operation and Test Software
Test operation refers to test setup in chapter 5. All tests were performed according to the procedures in ANSI C63.4: 2014. According to clause 3.1, all tests were performed on model Impacta 220 in this report.

4.3 Special Accessories and Auxiliary Equipment

Table 3: Auxiliary Equipment Used during Test

Description

Manufacturer

Model

Smart terminal

Intelbras

TI5000

S/N

Remark

N/A

Connecting with Impacta 220

4.4 Countermeasures to Achieve EMC Compliance
The test sample which has been tested contained the noise suppression parts as described in the Technical Construction File (TCF). No additional measures were employed to achieve compliance.

Prüfbericht - Produkte Test Report - Products
Prüfbericht - Nr.:
Test Report No.:

CN22SYO5 001

4.5 Test Setup Diagram

Diagram of Measurement Configuration for Radiation Test (Below 1GHz)

Seite 9 von 18 Page 9 of 18

Diagram of Measurement Configuration for Radiation Test (Above 1GHz)

Diagram of Measurement Configuration for Mains Conduction Measurement

Prüfbericht - Produkte Test Report - Products
Prüfbericht - Nr.: CN22SYO5 001
Test Report No.:
5 Test Results

5.1.1 Conducted Emission on AC Mains

RESULT:

Test Specification Test standard Basic standard Frequency range Classification Limits Kind of test site

: FCC Part 15.107(a) : ANSI C63.4:2014 : 0.15 ­ 30MHz : Class A : FCC Part 15.107(a) : Shielded Room

Test Setup Date of testing Input voltage Operation mode Ambient temperature Relative humidity Atmospheric pressure

: 2022-07-14 : AC 120V, 60Hz : A : 24.1  : 52.8 % : 101 kPa

For the measurement records, refer to the following plots.

Seite 10 von 18 Page 10 of 18
Pass

Prüfbericht - Produkte Test Report - Products
Prüfbericht - Nr.:
Test Report No.:

CN22SYO5 001

EUT Information
EUT Name: Order No: Model: Test mode: Test Voltage: Test By:/Review By: Test Standard: Tem./Hum./Pressure: Remark:

Impacta exchanges 168374467 Impacta 220 ON, Normal working AC 120V/50Hz Kevin Zhou/Gary Chen FCC Part 15B 24.1°C/52.8%//101kPa SR2

Seite 11 von 18 Page 11 of 18

Level in dB

Critical_Freqs

Frequency (MHz)

MaxPeak (dBµV)

0.162000 0.162000

48.88 ---

6.178500 6.234500

57.99 ---

6.698500 6.777500 7.282500

--60.82
---

7.285500 10.394000 10.526000

63.19 52.49
---

14.050000 14.214000

52.74 ---

Average (dBµV)
--42.51
--36.28 40.92
--41.48
----40.14 --41.89

Limit (dBµV)
65.36 55.36 60.00 50.00 50.00 60.00 50.00 60.00 60.00 50.00 60.00 50.00

Margin (dB)
16.48 12.85
2.01 13.72
9.08 -0.82 8.52 -3.19 7.51 9.86 7.26 8.11

Line
L1 L1 L1 L1 L1 L1 L1 L1 L1 L1 L1 L1

Corr. (dB)
9.9 9.9 10.3 10.3 10.3 10.3 10.3 10.3 10.3 10.3 10.4 10.4

Final_Result

Frequency (MHz)

QuasiPeak (dBµV)

6.178500

49.52

6.234500

---

6.698500

---

6.777500

54.27

7.282500

---

7.285500

55.97

Average (dBµV)
--32.83 36.63
--39.04
---

Limit (dBµV)
60.00 50.00 50.00 60.00 50.00 60.00

Margin (dB)
10.48 17.17 13.37
5.73 10.96
4.03

Meas. Time (ms)
3000.0 3000.0 3000.0 3000.0 3000.0 3000.0

Bandwidth (kHz)
9.000 9.000 9.000 9.000 9.000 9.000

Line
L1 L1 L1 L1 L1 L1

Corr. (dB)
10.3 10.3 10.3 10.3 10.3 10.3

Prüfbericht - Produkte Test Report - Products
Prüfbericht - Nr.:
Test Report No.:

CN22SYO5 001

EUT Information
EUT Name: Order No: Model: Test mode: Test Voltage: Test By:/Review By: Test Standard: Tem./Hum./Pressure: Remark:

Impacta exchanges 168374467 Impacta 220 ON, Normal working AC 120V/50Hz Kevin Zhou/Gary Chen FCC Part 15B 24.1°C/52.8%//101kPa SR2

Seite 12 von 18 Page 12 of 18

Level in dB

Critical_Freqs

Frequency (MHz)

MaxPeak (dBµV)

0.162000

48.68

0.162000

---

0.270000

39.90

0.274000

34.62

6.077500

---

6.098500

57.87

6.622500

60.06

6.690500

---

7.169500

---

7.178500

61.91

14.274000

51.82

14.274000

---

Average (dBµV)
--39.58
----36.55 ----39.03 41.74 ----41.10

Limit (dBµV)
65.36 55.36 61.12 61.00 50.00 60.00 60.00 50.00 50.00 60.00 60.00 50.00

Margin (dB)
16.68 15.78 21.22 26.38 13.45
2.13 -0.06 10.97 8.26 -1.91 8.18 8.90

Line
N N N N N N N N N N N N

Corr. (dB)
9.8 9.8 9.8 9.8 9.9 9.9 10.0 10.0 10.0 10.0 10.1 10.1

Final_Result

Frequency (MHz)

QuasiPeak (dBµV)

6.077500

---

6.098500

49.75

6.622500

54.56

6.690500

---

7.169500

---

7.178500

55.28

Average (dBµV)
34.07 -----
36.91 38.73
---

Limit (dBµV)
50.00 60.00 60.00 50.00 50.00 60.00

Margin (dB)
15.93 10.25
5.44 13.09 11.27
4.72

Meas. Time (ms)
3000.0 3000.0 3000.0 3000.0 3000.0 3000.0

Bandwidth (kHz)
9.000 9.000 9.000 9.000 9.000 9.000

Line
N N N N N N

Corr. (dB)
9.9 9.9 10.0 10.0 10.0 10.0

Prüfbericht - Produkte Test Report - Products

Prüfbericht - Nr.: CN22SYO5 001
Test Report No.:

Seite 13 von 18 Page 13 of 18

5.1.2 Radiated Emissions

RESULT:

Pass

Test Specification Test standard Basic standard Frequency range Classification Limits Kind of test site

: FCC Part 15.109(a) : ANSI C63.4:2014 : 30MHz to 5th harmonic of the highest frequency : Class A : FCC Part 15.109(a) : 3m Semi-anechoic Chamber

Test Setup Date of testing Input voltage Operation mode Ambient temperature Relative humidity Atmospheric pressure

: 2022-07-26 to 2022-08-03 : AC 120V, 60Hz : A : Refer to test result : Refer to test result : 101 kPa

For the measurement records, refer to the following plots. As for above 6GHz, only the noise-floors, thus no record for it.

Prüfbericht - Produkte Test Report - Products
Prüfbericht - Nr.:
Test Report No.:

CN22SYO5 001

EUT Information
EUT Name: Order No: Model: Test Mode: Test Voltage: Standard: Test By:/Review By: Tem./Hum./Pressure: Remark:

Impacta exchanges 168374467 30 Impacta 220 ON, Normal working AC 120V/60Hz FCC Part 15B Kevin Zhou/Gary Chen 24.1°C/50.8%/101kPa 3m chamber

Seite 14 von 18 Page 14 of 18

Level in dB/m

Critical_Freqs

Frequency (MHz)

MaxPeak

Limit

Margin Height Pol

(dBµV/m) (dBµV/m) (dB)

(cm)

99.840000 182.872000

39.46 42.20

53.50 53.50

14.04 11.30

200.0 H 200.0 H

266.583000 399.861000

38.28 44.11

56.00 56.00

17.72 11.89

100.0 H 100.0 H

739.361000 817.135000

44.81 47.09

56.00 56.00

11.19 8.91

100.0 H 100.0 H

Azimuth (deg)
203.0 51.0
192.0 350.0 334.0 326.0

Corr. (dB/m)
17.1 18.7 20.4 23.3 30.2 30.5

Final_Result

Frequency (MHz)

QuasiPea k
(dBµV/m)

817.135000

44.97

Limit (dBµV/m
)
56.00

Margin (dB)
11.03

Meas. Time (ms)

Bandwid Height Pol

th

(cm)

(kHz)

1000.0 120.000 100.0 H

Azimuth Corr. (deg) (dB/m)

326.0

30.5

Prüfbericht - Produkte Test Report - Products
Prüfbericht - Nr.:
Test Report No.:

CN22SYO5 001

EUT Information
EUT Name: Order No: Model: Test Mode: Test Voltage: Standard: Test By:/Review By: Tem./Hum./Pressure: Remark:

Impacta exchanges 168374467 30 Impacta 220 ON, Normal working AC 120V/60Hz FCC Part 15B Kevin Zhou/Gary Chen 24.1°C/50.8%/101kPa 3m chamber

Seite 15 von 18 Page 15 of 18

Level in dB/m

Critical_Freqs

Frequency (MHz)

MaxPeak

Limit

Margin Height Pol

(dBµV/m) (dBµV/m) (dB)

(cm)

180.738000

40.27

53.50 13.23 200.0 V

399.958000

43.53

56.00 12.47 200.0 V

488.810000

43.07

56.00 12.93 100.0 V

533.236000

42.38

56.00 13.62 200.0 V

817.155000

43.69

56.00 12.31 100.0 V

933.147000

45.76

56.00 10.24 100.0 V

Azimuth (deg)
130.0 136.0 218.0 115.0 184.0 141.0

Corr. (dB/m)
19.2 23.3 24.9 25.3 30.5 32.1

Final_Result

Frequency (MHz)

QuasiPea k
(dBµV/m)

933.147000

44.04

Limit (dBµV/m
)
56.00

Margin (dB)
11.96

Meas. Time (ms)

Bandwid Height Pol

th

(cm)

(kHz)

1000.0 120.000 100.0 V

Azimuth Corr. (deg) (dB/m)

141.0

32.1

Prüfbericht - Produkte Test Report - Products
Prüfbericht - Nr.:
Test Report No.:

CN22SYO5 001

EUT Information
EUT Name: Order No: Model: Test Mode: Test Voltage: Standard: Test By:/Review By: Tem./Hum./Pressure: Remark:

Impacta exchanges 168374467 30 Impacta 220 ON, Normal working AC 120V/60Hz FCC Part 15B Kevin Zhou/Gary Chen 24.1°C/51.3%/101kPa 3m chamber

Seite 16 von 18 Page 16 of 18

Level in dB/m

Critical_Freqs

Frequency (MHz)

MaxPeak Average

Limit Margin Height Pol

(dBµV/m) (dBµV/m) (dBµV/m) (dB)

(cm)

1050.500000

39.86

---

79.50 39.64 100.0 H

1050.500000

---

37.80

59.50 21.70 100.0 H

1128.500000

40.86

---

79.50 38.64 100.0 H

1128.500000

---

40.46

59.50 19.04 100.0 H

1206.500000

35.66

---

79.50 43.84 100.0 H

1206.500000

---

35.06

59.50 24.44 100.0 H

1284.500000

36.95

---

79.50 42.55 100.0 H

1284.500000

---

35.24

59.50 24.26 100.0 H

3829.000000

43.14

---

79.50 36.36 100.0 H

3829.000000

---

41.50

59.50 18.00 100.0 H

4358.000000

44.97

---

79.50 34.53 100.0 H

4358.000000

---

42.40

59.50 17.10 100.0 H

Azimuth (deg)
150.0 150.0 155.0 155.0 230.0 230.0 139.0 139.0 132.0 132.0 343.0 343.0

Corr. (dB/m)
-13.2 -13.2 -13.1 -13.1 -14.0 -14.0 -14.0 -14.0
0.0 0.0 2.1 2.1

Prüfbericht - Produkte Test Report - Products
Prüfbericht - Nr.:
Test Report No.:

CN22SYO5 001

EUT Information
EUT Name: Order No: Model: Test Mode: Test Voltage: Standard: Test By:/Review By: Tem./Hum./Pressure: Remark:

Impacta exchanges 168374467 30 Impacta 220 ON, Normal working AC 120V/60Hz FCC Part 15B Kevin Zhou/Gary Chen 24.1°C/51.3%/101kPa 3m chamber

Seite 17 von 18 Page 17 of 18

Level in dB/m

Critical_Freqs

Frequency (MHz)

MaxPeak Average

Limit Margin Height Pol

(dBµV/m) (dBµV/m) (dBµV/m) (dB)

(cm)

1050.500000

---

38.67

59.50 20.83 100.0 V

1051.000000

38.97

---

79.50 40.53 100.0 V

1128.500000

39.78

---

79.50 39.72 100.0 V

1128.500000

---

39.30

59.50 20.20 100.0 V

1206.500000

39.69

---

79.50 39.81 100.0 V

1206.500000

---

38.93

59.50 20.57 100.0 V

1284.500000

36.60

---

79.50 42.90 100.0 V

1284.500000

---

35.02

59.50 24.48 100.0 V

1440.000000

37.58

---

79.50 41.92 100.0 V

1440.000000

---

36.41

59.50 23.09 100.0 V

1517.500000

38.22

---

79.50 41.28 100.0 V

1517.500000

---

37.12

59.50 22.38 100.0 V

Azimuth (deg)
270.0 120.0 252.0 252.0 274.0 274.0 194.0 194.0 297.0 297.0 304.0 304.0

Corr. (dB/m)
-13.2 -13.2 -13.1 -13.1 -14.0 -14.0 -14.0 -14.0 -12.6 -12.6 -11.0 -11.0

Prüfbericht - Produkte Test Report - Products
Prüfbericht - Nr.:
Test Report No.:

CN22SYO5 001

6 Photographs of the Test Set-Up

For photographs of the test set-up, refer to the appendix A.

Seite 18 von 18 Page 18 of 18

7 List of Tables
Table 1: List of Test and Measurement Equipment..................................................................... 5 Table 2: Technical Specification of EUT ..................................................................................... 7 Table 3: Auxiliary Equipment Used during Test .......................................................................... 8



Related FCC IDs:

Search Any Device: