Brochure

MRCOOL GeoCool 48K BTU 4T Multi Positional 230V 1-Phase 60Hz DC Invert

PDF Viewing Options

Not Your Device? Search For Manuals or Datasheets below:


File Info : application/pdf, 4 Pages, 4.68MB

Document DEVICE REPORTmc-gci-br-eng-01 Home Outlet Direct ?v=1702320757
Inverter Series
Up to 70 EER DC Inverter Geothermal Heat Pump
Embrace comfort with the GeoCool® all DC Inverter Technology. Equipped with a highprecision Electronic Expansion Valve, allowing for more accurate temperature control while also keeping the utility bill down.
The flexibility of four independent modules makes it easy to meet the installation requirements of different air outlet methods and applications. Space constraints are less of an issue when a custom built layout is an option!
For a long term solution with lower maintenance costs, design your own GeoCool® Inverter Series Geothermal unit.

NOW
AVAILABLE!

All DC Inverter High-Precision Electronic Expansion Valve (EEV) Co-Axial Copper-Nickel Coil Heat Exchanger

Durable Build & Finish Multi-Position Installation Low Noise
Version Date: 10-09-23
www.mrcool.com

Inverter Series

 




















GeoCool® Vertical Downflow with pre-charged GeoCool
Quick Connect Line Set
 A-Coil Module: GCSCAM060GN  Blower Module: GCSBLM014  Compressor: GCSHPM060IN  GeoCool No-Vac Vertical Downflow
w/o Air Box 3/8 3/4 Prechg. Lineset: GCNV-VD00-3834

GeoCool® Vertical Upflow with pre-charged GeoCool
Quick Connect Line Set
 Blower Module:GCSBLM014  A-Coil Module: GCSCAM060GN  Compressor: GCSHPM060IN  GeoCool No-Vac Vertical Upflow w/o
Air Box 3/8 3/4 Prechg. Lineset: GCNV-VU00-3834

GeoCool® Vertical Upflow with Return Air Box and pre-charged GeoCool Quick Connect Line Set
 Blower Module: GCSBLM014  A-Coil Module: GCSCAM060GN  Return Air Box Module:
GCSAR048060  Compressor: GCSHPM060IN  GeoCool No-Vac Vertical Upflow w/
Air Box 3/8 3/4 Prechg. Lineset: GCNV-VUAB-3834

SPECIFICATIONS*
*Specifications are preliminary and subject to change.

OPEN LOOP

COOLING

HEATING

CLOSED LOOP

COOLING

HEATING

MODEL

LOAD FLUID FLOW AIRFLOW AIRFLOW CAPACITY EER

CAPACITY COP

CAPACITY EER

CAPACITY COP

(GPM)

(COOLING CFM) (HEATING CFM)

(BTU/HR)

(BTU/HR)

(BTU/HR)

(BTU/HR)

____________________________________________________________________________________________________________________________________________________________________

_C4_SO__OTM__OO_IN_NN_G___________PF__UA____RL__LT__________________77____..99__33______________________1__84__10__0__0__________________110__7__65__05____________________51__30__35__00__00______________7____02__.79____7__________________4__118__0__00__0__00________________46__..__22____________________4__14__6__55__00__00________________41__88__.__.27__99____________________4__90__8__00__0__00__________________3__5.__.41____

5 TON ____F_U__L_L_________7__.9_3___________1_4_0__0_________1_7_6_5_________6__2_0_0_0________2_1_.3_9__________5_5_0__0_0________3_._7__________5__5_6_0_0_________1_4_.4___________4_5__0_0_0_________3_._2__

PART

7.93

810

1050

13300

70.97

11000

5.9

14500

48.79

9800

5.1

____________________________________________________________________________________________________________________________________________________________________

ALL RATINGS BASED ON 208V / 60Hz / 1ph. HEATING CAPACITIES BASED ON 68.0°F DB / 59.0°F WB ENTERING AIR TEMPERATURE. COOLING CAPACITIES BASED ON 80.6°F DB / 66.2°F WB ENTERING AIR TEMPERATURE.

GeoCool® Vertical Split System with Return Air Box and MRCOOL Pre- Charged Line Set

If limited access is a constraint in your space, a Vertical Split system may be the ideal



configuration. A Vertical Split configuration would include a stand-alone Compressor

Module, separate from the A-coil Module, Blower Module, and Return Air Box.

This system would require the use of the MRCOOL No-Vac Quick Connect line set. MRCOOL offers multiples lengths for various application requirements.*

To build this configuration, all items will need to be selected and purchased individually.

 


From top to bottom, this configuration includes



the following units:

 Blower Module: GCSBLM014

 A-Coil Module: GCSCAM060GN

 Return Air Box Module: GCSAR048060  Compressor: GCSHPM060IN

 MRCOOL No-Vac Quick Connect line set: NVXX-3834

*Refer to MRCOOL Pre-Charged Line Sets for selection.

GeoCool® Horizontal Split System with MRCOOL Pre-Charged Line Set
If there is limited access to a space, a Horizontal Split system may be the choice. This split configuration would include a stand-alone Compressor Module, separate from the A-coil Module and Blower Module in a horizontal orientation. This system would require the use of the MRCOOL® No-Vac Quick Connect line set. MRCOOL® offers multiples lengths for various application requirements.* To build this configuration, all items will need to be selected and purchased individually.
From left to right, this configuration includes the following units:  Blower Module: GCSBLM014  A-Coil Module: GCSCAM060GN  Compressor: GCSHPM060IN  MRCOOL No-Vac Quick Connect line set: NVXX-3834
*Refer to MRCOOL Pre-Charged Line Sets for selection.

 

 

*All modules must be selected individually based on the desired configuration. Currently, there is not a model number for an entire system. The Vertical Upflow (with or without the return air box) and Vertical Downflow configurations have line sets designed for each system. Split Systems will require the user to select and purchase a MRCOOL Universal No-Vac line set based on the distance required for the application.
Refer to your dealer to purchase the additional, required accessories to complete a full geothermal system.

A-Coil Module GCSCAM060GN
Net Cabinet Dimensions:
A: 24.81" (630mm) C B: 22.43" (570mm)
C: 30.87" (785mm)
Net Weight:
124.58 Lbs (56.5Kg)

Compressor Module GCSHPM060IN
Net Cabinet Dimensions:
A: 24.81" (630mm) B: 22.44" (570mm) C C: 25.12" (638mm)
Net Weight:
231.53 Lbs (105Kg)

A B

A

B

Blower Module GCSBLM014

Return Air Box Module GCSAR048060

Net Cabinet
C
Dimensions:
A: 24.81" (630mm)

Net Cabinet C Dimensions:
A: 24.81" (630mm)

B: 22.43" (570mm)

B: 22.43" (570mm)

A

C: 19.12" (485mm)

B

A

C: 14.56" (370mm)

B

Net Weight:

Net Weight:

79.38 Lbs (36Kg)

36.38 Lbs (16.5Kg)

GeoCool® No-Vac Pre-Charged Line Sets

The pre-charged, GeoCool® No-Vac Line Sets,

designed specifically for the Vertical Upflow

A

configuration with or without Return Air Box and

the Vertical Downflow configuration, allow for

easy and fast installation.

A GCNV-VU00-3834
Dimensions (LxW): 39.195" x 12.55" (995.53 x 319mm)
Net Weight: 5.8 Lbs (2637g)

B GCNV-VUAB-3834
Dimensions (LxW): 53.131" x 12.55" (1349.53 x 319mm)
Net Weight: 6.48 Lbs (29420g)

C
B
C GCNV-VD00-3834 Dimensions (LxW): 57.695" x 12.55" (1465.53 x 319mm) Net Weight: 6.7 Lbs (3040g)


Adobe PDF Library 17.0 Adobe InDesign 18.5 (Macintosh)