Specification For 46 Watts
H-000520
Specification For 46 Watts
Not Your Device? Search For Manuals or Datasheets below:
File Info : application/pdf, 13 Pages, 1.17MB
Document DEVICE REPORT0000000208SHENZHEN HUNTKEY ELECTRIC CO., LTD Specification For 60 Watts/ Switching Mode Power Supply Product No./:P11-060246503R Model No./:HKA06024025-7F Customer/: File No./:EQS-731-6193 Revision/: V01 Date/: 2021-08-16 TABLE OF CONTENTS/ Approval Sheet Cover/ .................... E.C. List/ ............................................. Contents .................................................... 1. Electrical Specification/ .......................... 2. Environment Requirements/ .................... 3. Reliability Requirements/ ...................... 4. EMI/EMS Standards/ ...................... 5. Safety Standards/ .................................. 6. Mach. Outline Drawing/ ............................... 7. Label Drawing/ ........................................... 8. Package Drawing/ ................................ 9. Circuit Schematic Drawing/ ............ 10.PCB Drawing/PCB ............................... 11.Bill Of Material (BOM)/............ 12.Product Picture/ ........................... 13........................................................ Prepared By : Checked By : Approved By : P11-060246503R/HKA06024025-7F :Page 0 Q01-731-00-12-P2 2 SHENZHEN HUNTKEY ELECTRIC CO., LTD SPECIFICATION FOR APPROVAL CUSTOMER/ CUSTOMER P.N./ MODEL NO./ HKA06024025-7F APPROVAL NO./ PREPARED DATE/ 2021-08-16 CUSTOMER AUTHORIZED SIGNATURE/ Please return to us one copy of "SPECIFICATION FOR APPROVAL"with you approved signature. / / ADD: Huntkey Park,Banxue Road,Bantian,Shenzhen,Guangdong, P. R. China TEL/: 0755-89606666 FAX/: 0755-89606333 P.C./ : 518129 http://www.huntkey.com Prepared By : Checked By : Approved By : P11-060246503R/HKA06024025-7F :Page 1 Q01-731-00-12-P2 2 SHENZHEN HUNTKEY ELECTRIC CO., LTD E. C. LIST/ Rev. Description of Change/ Before/ After/ V01 Original Release --- Changed Date/ ECN No. 2021-08-16 --- P11-060246503R/HKA06024025-7F :Page 2 Q01-731-00-12-P2 2 SHENZHEN HUNTKEY ELECTRIC CO., LTD Contents/ 1ELECTRICAL SPECIFICATION/.................................................................................................................................... 4 1.1.SCOPE/............................................................................................................................................................................... 4 1.2.INPUT CHARACTERISTICS/................................................................................................................................... 4 1.3.OUTPUT CHARACTERISTICS/...............................................................................................................................4 1.4.PROTECTION REQUIREMENTS/............................................................................................................................5 2ENVIRONMENT REQUIREMENTS/..............................................................................................................................6 2.1. OPERATING TEMPERATURE AND RELATIVE HUMIDITY/......................................................... 6 2.2. STORAGE TEMPERATURE AND RELATIVE HUMIDITY/............................................................. 6 3RELIABILITY REQUIREMENTS/................................................................................................................................ 6 3.1. VIBRATION/..................................................................................................................................................................... 6 3.2.DROP IN/........................................................................................................................................................................... 6 3.3.MTBF QUALIFICATION/..................................................................................................................6 3.4.THE LIFETIME ELECTROLYTE CAPACITOR/.............................................................................................. 6 4EMI/EMS STANDARDS/EMI/EMS ...................................................................................................................................... 7 5SAFETY STANDARDS/.................................................................................................................................................. 8 5.1.DIELECTRIC STRENGTH(HI-POT)/().................................................................................................... 8 5.2.LEAKAGE CURRENT/...................................................................................................................................................8 5.3.INSULATION RESISTANCE/................................................................................................................................... 8 5.4.REGULATORY STANDARDS/.................................................................................................................................8 6MACH. OUTLINE DRAWING/.......................................................................................................................................... 9 7 LABEL DRAWING/......................................................................................................................................................... 11 8 PACKAGE DRAWING/...........................................................................................................................................12 P11-060246503R/HKA06024025-7F :Page 3 Q01-731-00-12-P2 2 SHENZHEN HUNTKEY ELECTRIC CO., LTD 1Electrical Specification/ 1.1.SCOPE/ The document details the electrical, mechanical and environmental specifications of a SMPS, the power supply provides 60W continuous output power . 60W(),. The power supply shall meet the RoHS requirements. RoHS . Description/ SMPS Adaptor(Wall mount)/ Open Frame/ Others/ SMPS Adaptor(Desk-top)/ SMPS Unit (With Case)/ 1.2.Input Characteristics/ 1.2.1. Input Voltage & Frequency/ The range of input voltage is from 90Vac to 264Vac with a single phase. 90Vac 264Vac, . Minimum/ Rating/ Maximum/ Input Voltage/ 90Vac 100Vac~240Vac 264Vac Input Frequency/ 47Hz 60Hz/50Hz 63Hz 1.2.2. Input AC Current/ 1.5Amax. @ 90Vac input & Full load/ 90Vac 1.5A 1.2.3. Inrush Current (cold start)/() Power supply inrush current shall be less than the ratings of its critical components (including bulk rectifiers, fuses, and surge limiting device) under all conditions of line voltage of Section 1. 2.1. 1.2.1 () 1.2.4. Average Efficiency / While input 115Vac and 230Vac, the average efficiency is more than 89%.The test point is at 25%,50%,75% and 100% of max load respectively. And the efficiency shall be a minimum of 79% at 10% max load(warm up after 30 minutes). 115Vac 230Vac 89% 25%,50%,75% 100% 10% 79% 1.2.5. No-Load Input Power Dissipation/ While input 115Vac or 230Vac and the output is no load, the input power loss must be less than 0.15W. 115Vac/230Vac 0.15W. 1.3.Output Characteristics/ 1.3.1.Static Output Characteristics <Vo & R+N>/<&+> Output Rated Load/ Peak Load Output Range R+N Remark P11-060246503R/HKA06024025-7F :Page 4 Q01-731-00-12-P2 2 SHENZHEN HUNTKEY ELECTRIC CO., LTD Rating Min. Load Max. Load +24.0V 0A 2.5A 22.8V ~ 25.2V 240mVp-p Ripple & Noise: Tested by a oscilloscope using 20MHz bandwidth and the output is paralleled a 0.1uF ceramic capacitor and a 10uF electrolysis capacitor. (Under the input Voltage 100~240Vac) : 20MHz , 0.1uF 10uF ( 100~240Vac) 1.3.2.Line/ Load Regulation// Output Load Condition/ Rating Min. Load Max. Load +24.0V 0A 2.5A 1.3.3.Turn on Delay Time/ Line Regulation 2% Load Regulation 5% Remark 3S max. @90Vac input & Full load/ 90Vac 3S 1.3.4. Hold-up Time/ 10mS min. @ Full load &115Vac/60Hz input turn off at worst case 115Vac/60Hz , 10mS 1.3.5.Rise Time/ 50mS max. @ Full load/ 50mS 1.3.6.Fall Time/ 20mS max. @ Full load/ 20mS 1.3.7.Output Overshoot / Undershoot// 10% max. When the power on or off/ 10% 1.3.8.Output Load Transient Response/ Output voltage is within 22.8-25.2V while the load step is from 50% to 100% of max load, R/S: 0.5A/uS, frequency: 100Hz and 5mS duration at 100% of max load. 22.8-25.2V ,: 50% 100%,: 0.5A/uS,: 100Hz, 100% 5mS. When the input voltage was 220Vac, output voltage is within 21.6-26.4V while the load step is from 1A to 5.5A, R/S: 0.5A/uS, frequency: 1Hz and 300mS duration at 5.5A load. 220V , 21.6-26.4V ,: 1A 5.5A,: 0.5A/uS,: 1Hz, 5.5A 300mS. 1.4.Protection Requirements/ 1.4.1.Over Current Protection/ OCP Point Limited: 3.2A~6.0A /: 3.2A~6.0A The output shall hiccup when the over current applied to the output, and shall be Self-recovery when the fault condition is removed ,,, 1.4.2.Short Circuit Protection/ P11-060246503R/HKA06024025-7F :Page 5 Q01-731-00-12-P2 2 SHENZHEN HUNTKEY ELECTRIC CO., LTD The input power shall decrease when the output is short to GND; the power supply shall not damage, and shall be self-recovery when the fault condition is removed ,,, 1.4.3.Over Voltage Protection/ The power supply shall be protected when the output is over voltage, and the power supply shall not be damaged , 2Environment Requirements/ 2.1. Operating Temperature and Relative Humidity/ 0 to +40 10%RH to 90%RHnon-condensing@Sea level shall below 5,000 meter 5,000 0 +40, 10%RH to 90%RH 2.2. Storage Temperature and Relative Humidity/ -20 to +85 5%RH to 95%RH non-condensing @ Sea level shall below 5,000 meter 5,000 -20 +85, 5%RH to 95%RH 3Reliability Requirements/ 3.1. Vibration/ 5 to 500Hz sweep at a shift gears for 20 minute for each of the perpendicular axes X, Y, Z thereinto :acceleration frequency for 10 m2/s3 at 5~10HZ; acceleration frequency for 3 m2/s3 at 10~200HZ; acceleration frequency for 1 m2/s3 at 200~500HZ : 5 to 500Hz , X, Y, Z 20 ,: 5~10HZ 10 m2/s3 10~200HZ 3 m2/s3200~500HZ 1 m2/s3 3.2.Drop in/ 1Corner, 3 Edges, 6 Surfaces each once, Height: 100cm, on the cement plane 1 , 3 , 6 , : 100 , 3.3.MTBF Qualification/ The MTBF shall be at least 50,000hours at 25, Full load and nominal input condition : 50,000 ,25 3.4.The lifetime electrolyte capacitor/ The lifetime of electrolyte capacitor shall be at least 43800hours at 30of 80%load and P11-060246503R/HKA06024025-7F :Page 6 Q01-731-00-12-P2 2 SHENZHEN HUNTKEY ELECTRIC CO., LTD 115Vac/230Vac input condition 43800 ,30 115Vac/230Vac 80% 3.5.Low Temperature Storage Test/ At -20, test of non-operated for 48 hours, the speed of temperature change is 1/min, (The distance at least 1~3cm between the products). No abnormality in electric and mechanical characteristic after 1.5 hours recovery at the room temperature. -20 48 1/min 1~3cm 1.5 3.6.High Temperature Damp Storage Test/ At 85 and 95%RH, test of non-operated for 48 hours, the speed of temperature change is 1/min, (The distance at least 1~3cm between the products). No abnormality in electric and mechanical characteristic after 1.5 hours recovery at the room temperature. 85 95% 48 1/min 1~3cm 1.5 3.7.High / Low Temperature Thermal Shock Test/ The products test of non-operated with no-packing, storage the products 1 hour at +85, then storage the products 1 hour at -20. The temperature change time must less than 5 minutes. Total 12 cycles shall be applied. (The distance at least 1~3cm between the products).No abnormality in electric and mechanical characteristic after 1.5 hours recovery at the room temperature. +85 1 -20 1 5 12 1~3cm 1.5 4EMI/EMS Standards/EMI/EMS Item N u m 1 Conducted CLASS B interference /Rating 2 Radiated CLASS B interference 3 Harmonic Class A Current 4 Voltage dmax 4% fluctuations Pst 1 and flicker 5 SURGE DM: ±4KVCM:±4KVRating: B Standards EN55032FCC part15GB 9254 EN55032FCC part15GB 9254 EN61000-3-2 EN61000-3-3 EN61000-4-5 EN55035 P11-060246503R/HKA06024025-7F :Page 7 Q01-731-00-12-P2 2 SHENZHEN HUNTKEY ELECTRIC CO., LTD 6 EFT ±1kVRating: B2min 0U 10msB 70U 500msC 7 DIP 0U 5000msC Drop to 0Ulasts 10msB rating Drop to 70Ulasts 500msC rating Drop to 0Ulasts 5000msC rating 8 ESD Contact: 8KV /Air15KV Rating: B 9 CS Test Voltage4VRatingA 10 RS Test Voltage4V/mRatingA EN61000-4-4 EN55035 EN61000-4-11 EN55035 EN61000-4-2 EN55035 EN61000-4-6 EN55035 EN61000-4-3 EN55035 Performance Criteria Description: A normal performance within limits specified by the manufacturer, requestor or purchaser. Btemporary loss of function or degradation of performance which ceases after the disturbance Ceases, and from which the equipment under test recovers its normal performance, without operator Intervention. Ctemporary loss of function or degradation of performance, the correction of which requires Operator intervention. Dloss of function or degradation of performance which is not recoverable, owing to damage to Hardware or software, or loss of data. A: B C D 5Safety Standards/ 5.1.Dielectric Strength(Hi-pot)/() Primary to Secondary: 1500Vac / 3.5mA / 60 seconds Or 2121Vdc / 3.5mA / 60 seconds : 1500Vac / 3.5mA/ 60 2121Vdc / 3.5mA / 60 5.2.Leakage Current/ 0.25mAmax. at 264Vac / 50Hz input/ 264Vac/50Hz 0.25mA 5.3.Insulation Resistance/ 100M min. @ primary to secondary add a 500Vdc test voltage 500Vdc , 100M 5.4.Regulatory Standards/ P11-060246503R/HKA06024025-7F :Page 8 Q01-731-00-12-P2 2 SHENZHEN HUNTKEY ELECTRIC CO., LTD IEC/UL/EN 62368GB4943IEC/UL/EN60950IEC/UL/EN 60065 IEC/EN 60335GB4706UL1026,UL1083,UL982 IEC/EN/UL 60601GB9706 IEC/EN61347GB15910UL8750 IEC/EN 61558 Country China IEC CCC CB Mark Europe CE/ERP/EMC South Korea KC+KCC+MEPS Australia/New Zealand RCM+GEMS+SAA+C-Tick Canada CSA+ICES+NRCAN Argentina IRAM-S Mark Country USA Japan Taiwan India Germany Singapore Russia Mark UL/FCC/DOE/CEC PSE BSMI BIS TUV PSB EAC 6Mach. Outline Drawing/ DC DC DC LED 116.2*51.5*32.2 BLACK UL1185,VW-1,80C,300V,18# 1.2M 4Pin BLUE **g P11-060246503R/HKA06024025-7F :Page 9 Q01-731-00-12-P2 2 SHENZHEN HUNTKEY ELECTRIC CO., LTD P11-060246503R/HKA06024025-7F :Page 10 Q01-731-00-12-P2 2 7Label Drawing/ SHENZHEN HUNTKEY ELECTRIC CO., LTD P11-060246503R/HKA06024025-7F :Page 11 Q01-731-00-12-P2 2 8Package Drawing/ SHENZHEN HUNTKEY ELECTRIC CO., LTD P11-060246503R/HKA06024025-7F :Page 12 Q01-731-00-12-P2 2