90948-22-72-22-PP002

Jason

RF Exposure

DongGuanShi WeizhiChuang Technology Co., Ltd WZC-W327 Three in one Charger 2A4WMWZC-W327 2A4WMWZCW327 wzc w327

PDF Viewing Options

Not Your Device? Search For Manuals or Datasheets below:


File Info : application/pdf, 12 Pages, 335.03KB

Document DEVICE REPORTGetApplicationAttachment.html?id=6236429
TEST REPORT

Report Number. ..................... : 90948-22-72-22-PP002 Date of issue.......................... : 2022-11-02

Tested by (+signature).......... :

Duke

Approved by (+signature) .... :

Jason

Testing Laboratory name ..... : SLG-CPC Testlaboratory Co., Ltd.

Address .................................. :

No. 11, Wu Song Road, Dongcheng District, Dongguan, Guangdong Province, China 523117

Applicant's name .................. : DongGuanShi WeizhiChuang Technology Co., Ltd

Address .................................. :

Room 801, Building 5, No.1, Fengjing Road, Daping, Tangxia Town, Dongguan City, Guangdong Province

Manufacturer's name .......... : DongGuanShi WeizhiChuang Technology Co., Ltd

Address .................................. :

Room 801, Building 5, No.1, Fengjing Road, Daping, Tangxia Town, Dongguan City, Guangdong Province

Factory's name .................... : DongGuanShi WeizhiChuang Technology Co., Ltd

Address .................................. :

Room 801, Building 5, No.1, Fengjing Road, Daping, Tangxia Town, Dongguan City, Guangdong Province

FCC Part 1(1.1310) and Part 2(2.1091) Standard(s) ............................ :
KDB 680106 D01 RF Exposure Wireless Charging App v03r01

Test item description ............ : Three in one Charger

Trade Mark ............................. : N/A

Model/Type reference ........... : W327

FCC ID .................................... : 2A4WMWZC-W327

Date of receipt of test item... : 2022-10-20

Date (s) of performance of test .......................................... :

2022-10-21 to 2022-10-30

Summary of Test Results ..... : Pass

The Summary of Test Results based on a technical opinion belongs to the standard(s).

General disclaimer:
This report shall not be reproduced except in full, without the written approval of SLG-CPC Testlaboratory Co., Ltd. The test results in the report only apply to the tested sample.

Address:No.11,WuSongRoad, DongchengDistrict,Dongguan,
GuangdongProvince,China523117

Page 1 of 12

Tel: 86-769-22607797 Fax: 86-769-22607907
http://www.cpcteam.com

90948-22-72-22-PP002

Page 2 of 12 TABLE OF CONTENT

1. SUMMARY OF TEST RESULT .....................................................................................................................4 2. GENERAL INFORMATION ...........................................................................................................................5
2.1. DESCRIPTION OF DEVICE (EUT) ........................................................................................................5 2.2. DESCRIPTION OF TEST MODES .........................................................................................................6 2.3. DESCRIPTION OF SUPPORT DEVICE.................................................................................................6 2.4. DESCRIPTION OF TEST FACILITY.......................................................................................................6 3. MEASURING DEVICE AND TEST EQUIPMENT.........................................................................................7 3.1. FOR MPE MEASUREMENT...................................................................................................................7 4. RF EXPOSURE.............................................................................................................................................8 4.1. MEASURING STANDARD......................................................................................................................8 4.2. REQUIMENTS ........................................................................................................................................8 4.3. TEST CONFIGURATION ........................................................................................................................9 4.4. BLOCK DIAGRAM OF TEST SETUP.....................................................................................................9 4.5. LIMITS...................................................................................................................................................10 4.6. MEASURING RESULTS ....................................................................................................................... 11

Address:No.11,WuSongRoad, DongchengDistrict,Dongguan,
GuangdongProvince,China523117

Tel: 86-769-22607797 Fax: 86-769-22607907
http://www.cpcteam.com

90948-22-72-22-PP002

Page 3 of 12 Modified Information

Version Ver.1.0

Report No. 90948-22-72-22-PP002

Revision Data 2022-11-02

Summary Original Version

Address:No.11,WuSongRoad, DongchengDistrict,Dongguan,
GuangdongProvince,China523117

Tel: 86-769-22607797 Fax: 86-769-22607907
http://www.cpcteam.com

90948-22-72-22-PP002

Page 4 of 12

1. SUMMARY OF TEST RESULT

Description of Test Item MPE

EMISSION
Standard & Limits
FCC Part 1(1.1310) and Part 2(2.1091) KDB 680106 D01 RF Exposure Wireless Charging App v03r01

Note: N/A is an abbreviation for Not Applicable.

Results Pass

Address:No.11,WuSongRoad, DongchengDistrict,Dongguan,
GuangdongProvince,China523117

Tel: 86-769-22607797 Fax: 86-769-22607907
http://www.cpcteam.com

90948-22-72-22-PP002

Page 5 of 12

2. GENERAL INFORMATION

2.1. Description of Device (EUT)

Product Name Trade Name Model Name Series Model
Output
Operation frequency Modulation Type Antenna Type

Three in one Charger
N/A
W327
/ Wireless Output 1: 2.5W for iWatch Wireless Output 2: 10W/7.5W/5W for Phone Wireless Output 3: 3W for AirPods 115-205kHz for Phone and Airpods 327kHz for iWatch MSK
Inductive Loop Antenna with 0dBi

Power Supply

Input: DC 5V 3A, 9V 2A

Hardware version number Software version number Connecting I/O Port(s)

V1.0 V1.0 Please refer to the User's Manual

Address:No.11,WuSongRoad, DongchengDistrict,Dongguan,
GuangdongProvince,China523117

Tel: 86-769-22607797 Fax: 86-769-22607907
http://www.cpcteam.com

90948-22-72-22-PP002

Page 6 of 12

2.2. Description of test modes
All the test modes were carried out with the EUT in normal operation,the final test mode of the EUT was the worst test mode for emission test,which was shown in this report and defined as:

Mode:

TEST MODE DESCRIPPTION

1

EUT + Wireless Output (Phone 10W) + Wireless Output (iWatch 2.5W) + Wireless Output (AirPods 3W)

2

EUT + Wireless Output (Phone 10W) + Wireless Output (iWatch 2.5W)

3

EUT + Wireless Output (Phone 10W) + Wireless Output (AirPods 3W)

4

EUT + Wireless Output (iWatch 2.5W) + Wireless Output (AirPods 3W)

5

EUT + Wireless Output (Phone 10W)

6

EUT + Wireless Output (Phone 7.5W)

7

EUT + Wireless Output (Phone 5W)

8

EUT + Wireless Output (iWatch 2.5W)

9

EUT + Wireless Output (AirPods 3W)

Note:

1. All test modes were pre-tested, but we only recorded the worst case in this report.The

worst case is mode 1

2.3. Description of Support Device

No.

Equipment

1.

Cellphone

2

Adapter

3

Watch

4

Earbuds

Trade name iPhone HUAWEI iPhone
AirPods Pro

Model IPhone12 HW-200675CD1
S8 A2190

S/N Power Cord

2.4. Description of Test Facility Site Description

EMC Lab.

: Accredited by FCC, October 04 2021 Designation Number: CN0126 Test Firm Registration Number: 27767 Accredited by A2LA, October 04 2021 The Certificate Registration Number is 6325.01

Name of Firm Site Location

: SLG-CPC Testlaboratory Co., Ltd. : No. 11, Wu Song Road, Dongcheng District, Dongguan,
Guangdong Province, China 523117

2.5. Measurement Uncertainty
Test Item Magentic fieid meansurements(9kHz~30MHz) Electrice fieid meansurements(9kHz~30MHz)

Uncertainty ±2.3% ±2.1%

This uncertainty represents an expanded uncertainty expressed at approximately the 95% confidencelevel using a coverage factor of k=2.

Address:No.11,WuSongRoad, DongchengDistrict,Dongguan,
GuangdongProvince,China523117

Tel: 86-769-22607797 Fax: 86-769-22607907
http://www.cpcteam.com

90948-22-72-22-PP002

Page 7 of 12

3. MEASURING DEVICE AND TEST EQUIPMENT

3.1. For MPE Measurement

Used

Equipment

Manufacturer Model No. Serial No.

Last Cal. Cal. Interval



E-Field Probe(100kHz-3GHz)

WG

AC-0013 2244/90.20 Apr. 24, 2022 1 Year

 Exposure Level Tester



EMF Electromagnetic Field Probe

WG Narda

EMR-20 2244/20 Apr. 24, 2022 1 Year EHP-200A 1802X11012 Mar 31, 2022 1 Year

Address:No.11,WuSongRoad, DongchengDistrict,Dongguan,
GuangdongProvince,China523117

Tel: 86-769-22607797 Fax: 86-769-22607907
http://www.cpcteam.com

90948-22-72-22-PP002

Page 8 of 12

4. RF EXPOSURE
4.1. Measuring Standard
FCC Part 1(1.1310) and Part 2(2.1091)
4.2. Requiments
Three different categories of transmitters are defined by the FCC in OET Bulletin 65. These categories are fixed installation, mobile, and portable and are defined as follows: o Fixed Installations: fixed location means that the device, including its antenna, is physically secured at a permanent location and is not able to be easily moved to another location. Additionally, distance to humans from the antenna is maintained to at least 2 meters. o Mobile Devices: a mobile device is defined as a transmitting device designed to be used in other than fixed locations and to be generally used in such a way that a separation distance of at least 20 centimeters is normally maintained between the transmitter's radiating structures and the body of the user or nearby persons. Transmitters designed to be used by consumers or workers that can be easily re-located, such as a wireless modem operating in a laptop computer, are considered mobile devices if they meet the 20 centimeter separation requirement. The FCC rules for evaluating mobile devices for RF compliance are found in 47 CFR §2.1091. o Portable Devices: a portable device is defined as a transmitting device designed to be used so that the radiating structure(s) of the device is/are within 20 centimeters of the body of the user. Portable device requirements are found in Section 2.1093 of the FCC's Rules (47 CFR§2.1093). The FCC also categorizes the use of the device as based upon the user's awareness and ability to exercise control over his or her exposure. The two categories defined are Occupational/ Controlled Exposure and General Population/Uncontrolled Exposure. These two categories are defined as follows: Occupational/Controlled Exposure: In general, occupational/controlled exposure limits are applicable to situations in which persons are exposed as a consequence of their employment, who have been made fully aware of the potential for exposure and can exercise control over their exposure. This exposure category is also applicable when the exposure is of a transient nature due to incidental passage through a location where the exposure levels may be higher than the general population/uncontrolled limits, but the exposed person is fully aware of the potential for exposure and can exercise control over his or her exposure by leaving the area or by some other appropriate means. Awareness of the potential for RF exposure in a workplace or similar environment can be provided through specific training as part of a RF safety program. If appropriate, warning signs and labels can also be used to establish such awareness by providing prominent information on the risk of potential exposure and instructions on methods to minimize such exposure risks. General Population/Uncontrolled Exposure: The general population / uncontrolled exposure limits are applicable to situations in which the general public may be exposed or in which persons who are exposed as a consequence of their employment may not be made fully aware of the potential for exposure or cannot exercise control over their exposure. Members of the general public would come under this category when exposure is not employment-related; for example, in the case of a wireless transmitter that exposes persons in its vicinity. Warning labels placed on low-power consumer devices such as cellular telephones are not considered sufficient to allow the device to be considered under the occupational/controlled category, and the general population/uncontrolled exposure limits apply to these devices.

Address:No.11,WuSongRoad, DongchengDistrict,Dongguan,
GuangdongProvince,China523117

Tel: 86-769-22607797 Fax: 86-769-22607907
http://www.cpcteam.com

90948-22-72-22-PP002

Page 9 of 12

4.3. Test configuration
1, The field strength of both E-field and H-field was measured at 15cm(the 15 cm measured from the center of the probe(s) to the edge of the device) using the equipment list above for determining compliance with the MPE requirements of FCC Part 1.1310. 2, The RF power density was measured at 3 ifferent charge conditions:. min load, mid load, max load. 3, Maximum E-field and H-field measurements were made 15cm from each side of the EUT. Along the side of the EUT and still 15cm away from the edge of the EUT, the field probes were positioned at the location where there is maximum field strength. The maximum E-field and H-field is reported below. 4, This device uses a wireless charging circuit for power transfer operating at the frequency of 115 ­ 205kHz. Thus, the 300kHz limits were used: E-field Limit = 614 (V/m); H-field limit = 1.63 (A/m). 5. The EUT were measured according to the dictates of KDB 680106D01v03

4.4. Block Diagram of Test Setup

EMR-20

Address:No.11,WuSongRoad, DongchengDistrict,Dongguan,
GuangdongProvince,China523117

Tel: 86-769-22607797 Fax: 86-769-22607907
http://www.cpcteam.com

90948-22-72-22-PP002 4.5. Limits

Page 10 of 12

Address:No.11,WuSongRoad, DongchengDistrict,Dongguan,
GuangdongProvince,China523117

Tel: 86-769-22607797 Fax: 86-769-22607907
http://www.cpcteam.com

90948-22-72-22-PP002

Page 11 of 12

4.6. Measuring Results
Result: a) Power transfer frequency is less that 1 Mhz.
Yes,The device operates in the frequency 115Khz-205khz,327khz. b) Output power from each primary coil is less than or equal to 15watts.
Yes,The maximum output power of the primary coil is Max 10W15W. c) The transfer system includes onle single primary and secondary coils. This includes charging systems that may have multiple primary coils and clients that are able to detect and allow coupling only between individual pairs of coils.
Yes, The transfer system including a charging system with only single primary coils is to detect and allow only between individual of coils. d) Client device is placed directly in contact with the transmitter.
Yes, Client device is placed directly in contact with the transmitter. e) Mobile exposure conditions only (portable exposure conditions art not covered by this exclusion).
Yes, Mobile exposure condition only. f) The aggregate H-Field strengths at 15 cm surrounding the device and 20 cm above the top surface form all simultaneous transmitting coils are demonstrated to be less than 50% of the MPE limit.
The EUT H-field strengths at 15 cm surrounding the device and 20 cm above the top surface are less than 50%the MPE limit.

TEST Data:

Test Mode: Mode 1(100% Load)

Electric Field Emissions

Test Position

Measure Value (V/m)

Top

2.69

Left

2.78

Right

2.19

Rear

2.35

Front

2.63

Bottom

2.47

Limit(V/m) 614 614 614 614 614 614

Magnetic Field Emissions Test Position
Top Left Right Rear Front Bottom

Measure Value (A/m) 0.0716 0.0754 0.0813 0.0687 0.0698 0.0820

Limit(A/m) 1.63 1.63 1.63 1.63 1.63 1.63

Address:No.11,WuSongRoad, DongchengDistrict,Dongguan,
GuangdongProvince,China523117

Tel: 86-769-22607797 Fax: 86-769-22607907
http://www.cpcteam.com

90948-22-72-22-PP002

Page 12 of 12

Test Mode: Mode 1(50% Load)

Electric Field Emissions

Test Position

Measure Value (V/m)

Top

2.10

Left

1.91

Right

2.03

Rear

2.58

Front

2.21

Bottom

2.44

Magnetic Field Emissions Test Position
Top Left Right Rear Front Bottom

Measure Value (A/m) 0.0693 0.0576 0.0542 0.0564 0.0526 0.0585

Test Mode: Mode 1(1% Load)

Electric Field Emissions

Test Position

Measure Value (V/m)

Top

1.83

Left

1.74

Right

1.49

Rear

1.90

Front

1.74

Bottom

1.71

Magnetic Field Emissions Test Position
Top Left Right Rear Front Bottom

Measure Value (A/m) 0.0191 0.0166 0.0155 0.0137 0.0139 0.0134

THE END

Limit(V/m) 614 614 614 614 614 614
Limit(A/m) 1.63 1.63 1.63 1.63 1.63 1.63
Limit(V/m) 614 614 614 614 614 614
Limit(A/m) 1.63 1.63 1.63 1.63 1.63 1.63

Address:No.11,WuSongRoad, DongchengDistrict,Dongguan,
GuangdongProvince,China523117

Tel: 86-769-22607797 Fax: 86-769-22607907
http://www.cpcteam.com

