DELL
Test report
Guilin Zhishen Information Technology Co.,Ltd. ZYPLB108 2AIHFZYPLB108 2AIHFZYPLB108 zyplb108
Not Your Device? Search For Manuals or Datasheets below:
File Info : application/pdf, 73 Pages, 2.76MB
Document DEVICE REPORTGetApplicationAttachment.html?id=7316673Report No.: BL-SZ2430252-601 TEST REPORT Applicant: Address: Equipment Type: Model Name: Brand Name: FCC ID: ISED Number: Test Standard: Sample Arrival Date: Test Date: Date of Issue: Guilin Zhishen Information Technology Co., Ltd. 09 Huangtong Road, Tieshan Industrial Zone, Qixing District, Guilin, Guangxi, China. ZHIYUN MOLUS B300/B500 COB Light PLB108 (refer to section 2.3) ZHIYUN 2AIHFZYPLB108 29921-ZYPLB108 47 CFR Part 15 Subpart C RSS-Gen Issue 5 RSS-247 Issue 3 (refer to section 3.1) Mar. 01, 2024 Apr. 14, 2024 - Apr. 17, 2024 May 13, 2024 ISSUED BY: Shenzhen BALUN Technology Co., Ltd. Tested by: Julie Zhu Checked by: Ye Hongji Approved by: Liao Jianming (Technical Director) _______________ _______________ _______________ Tel: +86-755-66850100 E-mail: [email protected] Page No. 1 / 73 Web: www.titcgroup.com Template No.: TRP-FCC&ISED 247 (2022-01-12) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Report No.: BL-SZ2430252-601 Version Rev. 01 Rev. 02 Revision History Issue Date Apr. 30, 2024 May 13, 2024 Revisions Initial Issue 1. Added the Serial Number in Section 2.3. 2. Corrected Section 4.2 Test Equipment List. 3. Updated Section A.5 Conducted Emissions. 4. Updated the 30 MHz to 1 GHz test data in Section A.6 Radiated Spurious Emission TABLE OF CONTENTS 1 GENERAL INFORMATION ......................................................................................................... 4 1.1 Test Laboratory .............................................................................................................. 4 1.2 Test Location.................................................................................................................. 4 2 PRODUCT INFORMATION ......................................................................................................... 5 2.1 Applicant Information...................................................................................................... 5 2.2 Manufacturer Information ............................................................................................... 5 2.3 General Description for Equipment under Test (EUT) ................................................... 5 2.4 Technical Information ..................................................................................................... 6 3 SUMMARY OF TEST RESULTS................................................................................................. 7 3.1 Test Standards ............................................................................................................... 7 3.2 Test Verdict .................................................................................................................... 7 4 GENERAL TEST CONFIGURATIONS ........................................................................................ 8 4.1 Test Environments ......................................................................................................... 8 4.2 Test Equipment List........................................................................................................ 8 4.3 Test Software List........................................................................................................... 8 4.4 Measurement Uncertainty .............................................................................................. 9 4.5 Description of Test Setup ............................................................................................... 9 4.6 Measurement Results Explanation Example................................................................ 12 5 TEST ITEMS.............................................................................................................................. 13 5.1 Antenna Requirements................................................................................................. 13 Tel: +86-755-66850100 E-mail: [email protected] Page No. 2 / 73 Web: www.titcgroup.com Template No.: TRP-FCC&ISED 247 (2022-01-12) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Report No.: BL-SZ2430252-601 5.2 Output Power ............................................................................................................... 14 5.3 Occupied Bandwidth .................................................................................................... 16 5.4 Conducted Spurious Emission ..................................................................................... 17 5.5 Band Edge (Authorized-band band-edge).................................................................... 19 5.6 Conducted Emission .................................................................................................... 21 5.7 Radiated Spurious Emission ........................................................................................ 22 5.8 Band Edge (Restricted-band band-edge)..................................................................... 27 5.9 Power Spectral density (PSD) ...................................................................................... 28 ANNEX A TEST RESULT ............................................................................................................. 29 A.1 Output Power, E.I.R.P, Duty Cycle............................................................................... 29 A.2 Occupied Bandwidth .................................................................................................... 33 A.3 Conducted Spurious Emissions ................................................................................... 37 A.4 Band Edge (Authorized-band band-edge).................................................................... 42 A.5 Conducted Emissions................................................................................................... 45 A.6 Radiated Spurious Emission ........................................................................................ 49 A.7 Band Edge (Restricted-band band-edge)..................................................................... 65 A.8 Power Spectral Density (PSD) ..................................................................................... 69 ANNEX B TEST SETUP PHOTOS ............................................................................................... 72 ANNEX C EUT EXTERNAL PHOTOS .......................................................................................... 72 ANNEX D EUT INTERNAL PHOTOS ........................................................................................... 72 Tel: +86-755-66850100 E-mail: [email protected] Page No. 3 / 73 Web: www.titcgroup.com Template No.: TRP-FCC&ISED 247 (2022-01-12) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Report No.: BL-SZ2430252-601 1 GENERAL INFORMATION 1.1 Test Laboratory Name Address Phone Number Shenzhen BALUN Technology Co., Ltd. Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China +86 755 6685 0100 1.2 Test Location Name Location Accreditation Certificate Shenzhen BALUN Technology Co., Ltd. Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China 1/F, Building B, Ganghongji High-tech Intelligent Industrial Park, No. 1008, Songbai Road, Yangguang Community, Xili Sub-district, Nanshan District, Shenzhen, Guangdong Province, P. R. China The laboratory is a testing organization accredited by FCC as a accredited testing laboratory. The designation number is CN1196. The laboratory has been listed by Industry Canada to perform electromagnetic emission measurements. The recognition numbers of test site are 11524A. Tel: +86-755-66850100 E-mail: [email protected] Page No. 4 / 73 Web: www.titcgroup.com Template No.: TRP-FCC&ISED 247 (2022-01-12) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Report No.: BL-SZ2430252-601 2 PRODUCT INFORMATION 2.1 Applicant Information Applicant Address Guilin Zhishen Information Technology Co., Ltd. 09 Huangtong Road, Tieshan Industrial Zone, Qixing District, Guilin, Guangxi, China. 2.2 Manufacturer Information Manufacturer Address Guilin Zhishen Information Technology Co., Ltd. 09 Huangtong Road, Tieshan Industrial Zone, Qixing District, Guilin, Guangxi, China. 2.3 General Description for Equipment under Test (EUT) EUT Name Model Name Under Test Series Model Name Description of Model name differentiation Serial Number Hardware Version Software Version Dimensions (Approx.) Weight (Approx.) ZHIYUN MOLUS B300/B500 COB Light PLB108 PLB106 1.The PLB108 and PLB106 have different built-in power modules. As A result, the input parameters of the AC interface are different. (The PLB108 uses 100-240V to 50/60Hz 6.5A max; PLB106 input 100240V~ 50/60Hz 4A Max); 2.PLB108 and PLB106 LED light board is different; 3.PLB108 drive board (D board) than PLB106 drive board (D board) more capacitors C12, C13, diode D5, D30, MOS tube Q4, Q22, the rest are the same; Except for the above three differences, everything else is the same. (this information provided by the applicant) 9080FA0EE010033 V1.0 N/A N/A N/A Tel: +86-755-66850100 E-mail: [email protected] Page No. 5 / 73 Web: www.titcgroup.com Template No.: TRP-FCC&ISED 247 (2022-01-12) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Report No.: BL-SZ2430252-601 2.4 Technical Information Network and Wireless Bluetooth (BLE) connectivity The requirement for the following technical information of the EUT was tested in this report: Modulation Technology DTS Modulation Type GFSK Mobile Product Type Portable Fix Location Transfer Rate 1 Mbps, 2 Mbps Frequency Range Number of Channel The frequency range used is 2400 MHz to 2483.5 MHz. 40 (at intervals of 2 MHz) Note 1 Tested Channel 1 Mbps: 0 (2402 MHz), 19 (2440 MHz), 39 (2480 MHz) 2 Mbps: 1 (2404 MHz), 19 (2440 MHz), 38 (2478 MHz) Antenna Type FPC Antenna Antenna Gain 1.78 dBi Antenna Impedance 50 Antenna System (MIMO Smart Antenna) N/A Note 1: 2 Mbps does not support Channel 0, Channel 12, and Channel 39. Tel: +86-755-66850100 E-mail: [email protected] Page No. 6 / 73 Web: www.titcgroup.com Template No.: TRP-FCC&ISED 247 (2022-01-12) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Report No.: BL-SZ2430252-601 3 SUMMARY OF TEST RESULTS 3.1 Test Standards No. Identity Document Title 1 47 CFR Part 15, Subpart C Intentional radiators of radio frequency equipment 2 RSS-Gen Issue 5 General Requirements for Compliance of Radio Apparatus Digital Transmission Systems (DTSs), Frequency Hopping 3 RSS-247 Issue 3 Systems(FHSs) and Licence-Exemp Local Area Network (LE-LAN) Devices 4 ANSI C63.10-2013 American National Standard for Testing Unlicensed Wireless Devices KDB 558074 D01 15.247 Guidance for compliance measurements on digital transmission 5 system, frequency hopping spread spectrum system, and hybrid Meas Guidance v05r02 system devices operating under section 15.247 of the FCC rules 3.2 Test Verdict No. Description FCC Part No. ISED Part No. Channel Test Result Verdict 1 Antenna Requirement 15.203 RSS-247, 5.4 (f) N/A -- PassNote1 2 Output Power 15.247(b) RSS-247, 5.4 (d) Low/Middle/ High ANNEX A.1 Pass Occupied 3 Bandwidth 15.247(a) RSS-GEN, 6.7; Low/Middle/ ANNEX A.2 RSS-247, 5.2 (a) High Pass 4 Conducted Spurious Emission 15.247(d) RSS-247, 5.5 Low/Middle/ High ANNEX A.3 Pass Band 5 Edge(Authorized- 15.247(d) RSS-247, 5.5; Low/High ANNEX A.4 Pass band band-edge) Conducted 6 Emission 15.207 RSS-GEN, 8.8 Low/Middle/ High ANNEX A.5 Pass 7 Radiated Spurious Emission 15.209 15.247(d) RSS-247, 5.5 Low/Middle/ High ANNEX A.6 Pass Band 8 Edge(Restricted- band band-edge) 15.209 15.247(d) RSS-247, 5.5 Low/High ANNEX A.7 Pass 9 Power spectral density (PSD) 15.247(e) RSS-247, 5.2 (b) Low/Middle/ High ANNEX A.8 Pass 10 Receiver Spurious Emissions -- RSS-Gen, 7.4 -- N/A N/ANote2 Note 1: The EUT has a permanently and irreplaceable attached antenna, which complies with the requirement FCC 15.203. Note 2: Only radio communication receivers operating in stand-alone mode within the band 30-960 MHz, as well as scanner receivers, are subject to Industry Canada requirements, so this test is not applicable. Tel: +86-755-66850100 E-mail: [email protected] Page No. 7 / 73 Web: www.titcgroup.com Template No.: TRP-FCC&ISED 247 (2022-01-12) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Report No.: BL-SZ2430252-601 4 GENERAL TEST CONFIGURATIONS 4.1 Test Environments During the measurement, the normal environmental conditions were within the listed ranges: Relative Humidity Atmospheric Pressure Temperature Working Voltage of the EUT 51% to 66% 100 kPa to 102 kPa NT (Normal Temperature) NV (Normal Voltage) +21.9 to +24.8 170 V 4.2 Test Equipment List Description Spectrum Analyzer Spectrum Analyzer Test Antenna-Horn Test Antenna-Horn Anechoic Chamber Amplifier Manufacturer KEYSIGHT KEYSIGHT SCHWARZBECK A-INFO RAINFORD COM-MV Amplifier COM-MV EMI Receiver Test Antenna-Loop Amplifier Anechoic Chamber EMI Receiver Test Antenna-Bi-Log Amplifier Anechoic Chamber EMI Receiver LISN Shielded Enclosure ROHDE&SCHWARZ SCHWARZBECK COM-MV EMC Electronic Co., Ltd Agilent SCHWARZBECK COM-MV YiHeng KEYSIGHT SCHWARZBECK YiHeng Electronic Co., Ltd Model N9020A N9020A BBHA 9120D LB-180400KF 9m*6m*6m LSCX_LNA112G-01 XKu_LNA718G-01 ESRP FMZB 1519 ZT30-1000M 20.10*11.60*7. 35m N9038A VULB 9168 ZT30-1000M 9m*6m*6m N9010B NSLK 8127 3.5m*3.1m*2.8 m Serial No. MY50330200 MY50531259 02460 J211060273 140 Cal. Date 2023.05.16 2023.09.05 2021.05.20 2021.07.02 2022.02.19 Cal. Due 2024.05.15 2024.09.04 2024.05.19 2024.07.01 2024.08.15 7210214 2023.09.05 2024.09.04 7210209 2023.09.05 2024.09.04 101036 1519-037 B2018054558 2023.09.05 2024.01.23 2023.12.05 2024.09.04 2025.01.22 2024.12.04 130 2021.08.15 2024.08.14 MY55330120 9168-00867 B2017119081 142 MY57110309 8127-687 2023.09.05 2022.04.12 2023.12.05 2021.08.19 2023.09.05 2023.05.16 2024.09.04 2025.04.11 2024.12.04 2024.08.18 2024.09.04 2024.05.15 112 2022.02.19 2025.02.18 4.3 Test Software List Description BL410R BL410E Manufacturer BALUN BALUN Software Version V2.1.1.488 V22.930 Serial No. N/A N/A Applicable test Setup The section 4.5.1 The section 4.5.2&4.5.3&4.5.4&4.5.5 Tel: +86-755-66850100 E-mail: [email protected] Page No. 8 / 73 Web: www.titcgroup.com Template No.: TRP-FCC&ISED 247 (2022-01-12) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Report No.: BL-SZ2430252-601 4.4 Measurement Uncertainty The following measurement uncertainty levels have been estimated for tests performed on the EUT as specified in CISPR 16-4-2. This uncertainty represents an expanded uncertainty expressed at approximately the 95% confidence level using a coverage factor of k=2. Parameters Uncertainty Occupied Channel Bandwidth 2.8% RF output power, conducted 1.28 dB Power Spectral Density, conducted 1.30 dB Unwanted Emissions, conducted 1.84 dB All emissions, radiated 5.36 dB Temperature 0.8°C Humidity 4% 4.5 Description of Test Setup 4.5.1 For Antenna Port Test Conducted value (dBm) = Measurement value (dBm) + cable loss (dB) For example: the measurement value is 10 dBm and the cable 0.5dBm used, then the final result of EUT: Conducted value (dBm) = 10 dBm + 0.5 dB = 10.5 dBm (Diagram 1) Tel: +86-755-66850100 E-mail: [email protected] Page No. 9 / 73 Web: www.titcgroup.com Template No.: TRP-FCC&ISED 247 (2022-01-12) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Report No.: BL-SZ2430252-601 4.5.2 For AC Power Supply Port Test (Diagram 2) 4.5.3 For Radiated Test (Below 30 MHz) (Diagram 3) Tel: +86-755-66850100 E-mail: [email protected] Page No. 10 / 73 Web: www.titcgroup.com Template No.: TRP-FCC&ISED 247 (2022-01-12) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Report No.: BL-SZ2430252-601 4.5.4 For Radiated Test (30 MHz-1 GHz) (Diagram 4) 4.5.5 For Radiated Test (Above 1 GHz) (Diagram 5) Tel: +86-755-66850100 E-mail: [email protected] Page No. 11 / 73 Web: www.titcgroup.com Template No.: TRP-FCC&ISED 247 (2022-01-12) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Report No.: BL-SZ2430252-601 4.6 Measurement Results Explanation Example 4.6.1 For conducted test items: The offset level is set in the spectrum analyzer to compensate the RF cable loss and attenuator between EUT conducted output port and spectrum analyzer. With the offset compensation, the spectrum analyzer reading level is exactly the EUT RF output level. The spectrum analyzer offset is derived from RF cable loss and attenuator factor. Offset = RF cable loss + attenuator factor. 4.6.2 For radiated band edges and spurious emission test: E = EIRP 20log D + 104.8 where: E = electric field strength in dBV/m, EIRP = equivalent isotropic radiated power in dBm D = specified measurement distance in meters. Tel: +86-755-66850100 E-mail: [email protected] Page No. 12 / 73 Web: www.titcgroup.com Template No.: TRP-FCC&ISED 247 (2022-01-12) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Report No.: BL-SZ2430252-601 5 TEST ITEMS 5.1 Antenna Requirements 5.1.1 Relevant Standards FCC §15.203 & 15.247(b); RSS-247, 5.4 (f) An intentional radiator shall be designed to ensure that no antenna other than that furnished by the responsible party shall be used with the device. The use of a permanently attached antenna or of an antenna that uses a unique coupling to the intentional radiator shall be considered sufficient to comply with the provisions of this section. The manufacturer may design the unit so that a broken antenna can be replaced by the user, but the use of a standard antenna jack or electrical connector is prohibited. This requirement does not apply to carrier current devices or to devices operated under the provisions of § 15.211, § 15.213, § 15.217, § 15.219, or § 15.221. Further, this requirement does not apply to intentional radiators that must be professionally installed, such as perimeter protection systems and some field disturbance sensors, or to other intentional radiators which, in accordance with § 15.31(d), must be measured at the installation site. However, the installer shall be responsible for ensuring that the proper antenna is employed so that the limits in this part are not exceeded. If directional gain of transmitting antennas is greater than 6 dBi, the power shall be reduced by the same level in dB comparing to gain minus 6 dBi. For the fixed point-to-point operation, the power shall be reduced by one dB for every 3 dB that the directional gain of the antenna exceeds 6 dBi. The use of a permanently attached antenna or of an antenna that uses a unique coupling to the intentional radiator shall be considered sufficient to comply with the FCC rule. 5.1.2 Antenna Anti-Replacement Construction The Antenna Anti-Replacement as following method: Protected Method Description The antenna is embedded in the An embedded-in antenna design is used. product. Reference Documents Photo Item Please refer to the EUT Photo documents. 5.1.3 Antenna Gain The antenna peak gain of EUT is less than 6 dBi. Therefore, it is not necessary to reduce maximum peak output power limit. Tel: +86-755-66850100 E-mail: [email protected] Page No. 13 / 73 Web: www.titcgroup.com Template No.: TRP-FCC&ISED 247 (2022-01-12) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Report No.: BL-SZ2430252-601 5.2 Output Power 5.2.1 Test Limit FCC § 15.247(b) For systems using digital modulation in the 902-928 MHz, 2400-2483.5 MHz, and 5725-5850 MHz bands: 1 Watt. As an alternative to a peak power measurement, compliance with the one Watt limit can be based on a measurement of the maximum conducted output power. Maximum Conducted Output Power is defined as the total transmit power delivered to all antennas and antenna elements averaged across all symbols in the signaling alphabet when the transmitter is operating at its maximum power control level. Power must be summed across all antennas and antenna elements. RSS-247, 5.4 (d) For DTSs employing digital modulation techniques operating in the bands 902-928 MHz and 24002483.5 MHz, the maximum peak conducted output power shall not exceed 1W. Except as provided in Section 5.4(5), the e.i.r.p. shall not exceed 4 W. 5.2.2 Test Setup See section 4.5.1 for test setup description for the antenna port. The photo of test setup please refer to ANNEX B. 5.2.3 Test Procedure a) Maximum peak conducted output power This procedure shall be used when the measurement instrument has available a resolution bandwidth that is greater than the DTS bandwidth. Set the RBW DTS bandwidth. Set VBW 3 x RBW. Set span 3 x RBW Sweep time = auto couple. Detector = peak. Trace mode = max hold. Allow trace to fully stabilize. Use peak marker function to determine the peak amplitude level. EIRP= Maximum peak conducted output power +Antenna Gain. b) Measurements of duty cycle The zero-span mode on a spectrum analyzer or EMI receiver if the response time and spacing between bins on the sweep are sufficient to permit accurate measurements of the on and off times of the transmitted signal. Set the center frequency of the instrument to the center frequency of the transmission. Tel: +86-755-66850100 E-mail: [email protected] Page No. 14 / 73 Web: www.titcgroup.com Template No.: TRP-FCC&ISED 247 (2022-01-12) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Report No.: BL-SZ2430252-601 Set RBW OBW if possible; otherwise, set RBW to the largest available value. Set VBW RBW. Set detector = peak or average. The zero-span measurement method shall not be used unless both RBW and VBW are > 50/T and the number of sweep points across duration T exceeds 100. (For example, if VBW and/or RBW are limited to 3 MHz, then the zero-span method of measuring duty cycle shall not be used if T 16.7 microseconds.) 5.2.4 Test Result Please refer to ANNEX A.1. Tel: +86-755-66850100 E-mail: [email protected] Page No. 15 / 73 Web: www.titcgroup.com Template No.: TRP-FCC&ISED 247 (2022-01-12) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Report No.: BL-SZ2430252-601 5.3 Occupied Bandwidth 5.3.1 Limit FCC §15.247(a); RSS-247, 5.2 (a); RSS-GEN, 6.7 Make the measurement with the spectrum analyzer's resolution bandwidth (RBW) = 100 kHz. In order to make an accurate measurement, set the span greater than RBW. The 6 dB bandwidth must be greater than 500 kHz. 5.3.2 Test Setup See section 4.5.1 for test setup description for the antenna port. The photo of test setup please refer to ANNEX B. 5.3.3 Test Procedure Use the following spectrum analyzer settings: Set RBW = 100 kHz. Set the video bandwidth (VBW) 3 RBW. Detector = Peak. Trace mode = max hold. Sweep = auto couple. Allow the trace to stabilize. Measure the maximum width of the emission that is constrained by the frequencies associated with the two outermost amplitude points (upper and lower frequencies) that are attenuated by 6 dB relative to the maximum level measured in the fundamental emission. 5.3.4 Test Result Please refer to ANNEX A.2. Tel: +86-755-66850100 E-mail: [email protected] Page No. 16 / 73 Web: www.titcgroup.com Template No.: TRP-FCC&ISED 247 (2022-01-12) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Report No.: BL-SZ2430252-601 5.4 Conducted Spurious Emission 5.4.1 Limit FCC §15.247(d); RSS-247, 5.5 In any 100 kHz bandwidth outside the frequency band in which the spread spectrum or digitally modulated intentional radiator is operating, the radio frequency power that is produced by the intentional radiator shall be at least 20 dB below that in the 100 kHz bandwidth within the band that contains the highest level of the desired power, based on either an RF conducted or a radiated measurement. 5.4.2 Test Setup See section 4.5.1 for test setup description for the antenna port. The photo of test setup please refer to ANNEX B. 5.4.3 Test Procedure The DTS rules specify that in any 100 kHz bandwidth outside of the authorized frequency band, the power shall be attenuated according to the following conditions: a) If the maximum peak conducted output power procedure was used to demonstrate compliance as described in 9.1, then the peak output power measured in any 100 kHz bandwidth outside of the authorized frequency band shall be attenuated by at least 20 dB relative to the maximum in-band peak PSD level in 100 kHz (i.e., 20 dBc). b) If maximum conducted (average) output power was used to demonstrate compliance as described in 9.2, then the peak power in any 100 kHz bandwidth outside of the authorized frequency band shall be attenuated by at least 30 dB relative to the maximum in-band peak PSD level in 100 kHz (i.e., 30 dBc). c) In either case, attenuation to levels below the 15.209 general radiated emissions limits is not required. The following procedures shall be used to demonstrate compliance to these limits. Note that these procedures can be used in either an antenna-port conducted or radiated test set-up. Radiated tests must conform to the test site requirements and utilize maximization procedures defined herein. Reference level measurement: Establish a reference level by using the following procedure: Set instrument center frequency to DTS channel center frequency. Set the span to 1.5 times the DTS bandwidth. Set the RBW = 100 kHz. Set the VBW 3 x RBW. Detector = peak. Sweep time = auto couple. Trace mode = max hold. Allow trace to fully stabilize. Tel: +86-755-66850100 E-mail: [email protected] Page No. 17 / 73 Web: www.titcgroup.com Template No.: TRP-FCC&ISED 247 (2022-01-12) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Report No.: BL-SZ2430252-601 Use the peak marker function to determine the maximum PSD level. Emission level measurement: Use the following spectrum analyzer settings: Span = wide enough to capture the peak level of the in-band emission and all spurious emissions (e.g., harmonics) from the lowest frequency generated in the EUT up through the 10th harmonic. Typically, several plots are required to cover this entire span. Set the RBW = 100 kHz. Set the VBW 3 x RBW. Detector = peak. Sweep time = auto couple. Trace mode = max hold. Allow trace to fully stabilize. Use the peak marker function to determine the maximum amplitude level. Ensure that the amplitude of all unwanted emissions outside of the authorized frequency band (excluding restricted frequency bands) are attenuated by at least the minimum requirements specified in 11.1 a) or 11.1 b). Report the three highest emissions relative to the limit. 5.4.4 Test Result Please refer to ANNEX A.3. Tel: +86-755-66850100 E-mail: [email protected] Page No. 18 / 73 Web: www.titcgroup.com Template No.: TRP-FCC&ISED 247 (2022-01-12) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Report No.: BL-SZ2430252-601 5.5 Band Edge (Authorized-band band-edge) 5.5.1 Limit FCC §15.247(d); RSS-247, 5.5 In any 100 kHz bandwidth outside the frequency band in which the spread spectrum or digitally modulated intentional radiator is operating, the radio frequency power that is produced by the intentional radiator shall be at least 20 dB below that in the 100 kHz bandwidth within the band that contains the highest level of the desired power, based on either an RF conducted or a radiated measurement. 5.5.2 Test Setup See section 4.5.1 for test setup description for the antenna port. The photo of test setup please refer to ANNEX B. 5.5.3 Test Procedure The following procedures may be used to determine the peak or average field strength or power of an unwanted emission that is within 2 MHz of the authorized band edge. If a peak detector is utilized, use the procedure described in 13.2.1. Use the procedure described in 13.2.2 when using an average detector and the EUT can be configured to transmit continuously (i.e., duty cycle 98%). Use the procedure described in 13.2.3 when using an average detector and the EUT cannot be configured to transmit continuously but the duty cycle is constant (i.e., duty cycle variations are less than ± 2 percent). Use the procedure described in 13.2.4 when using an average detector for those cases where the EUT cannot be configured to transmit continuously and the duty cycle is not constant (duty cycle variations equal or exceed 2 percent). When using a peak detector to measure unwanted emissions at or near the band edge (within 2 MHz of the authorized band), the following integration procedure can be used. Set instrument center frequency to the frequency of the emission to be measured (must be within 2 MHz of the authorized band edge). Set span to 2 MHz RBW = 100 kHz. VBW 3 x RBW. Detector = peak. Sweep time = auto. Trace mode = max hold. Allow sweep to continue until the trace stabilizes (required measurement time may increase for low duty cycle applications) Compute the power by integrating the spectrum over 1 MHz using the analyzer's band power measurement function with band limits set equal to the emission frequency (femission) ± 0.5 MHz. If the instrument does not have a band power function, then sum the amplitude levels (in power units) at 100 kHz intervals extending across the 1 MHz spectrum defined by femission ± 0.5 MHz. Tel: +86-755-66850100 E-mail: [email protected] Page No. 19 / 73 Web: www.titcgroup.com Template No.: TRP-FCC&ISED 247 (2022-01-12) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Report No.: BL-SZ2430252-601 5.5.4 Test Result Please refer to ANNEX A.4. Tel: +86-755-66850100 E-mail: [email protected] Page No. 20 / 73 Web: www.titcgroup.com Template No.: TRP-FCC&ISED 247 (2022-01-12) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Report No.: BL-SZ2430252-601 5.6 Conducted Emission 5.6.1 Limit FCC §15.207; RSS-GEN, 8.8 For an intentional radiator that is designed to be connected to the public utility (AC) power line, the radio frequency voltage that is conducted back onto the AC power line on any frequency within the band 150 kHz to 30 MHz shall not exceed the limits in the following table, as measured using a 50µH/50 line impedance stabilization network (LISN). Frequency range (MHz) 0.15 - 0.50 0.50 - 5 0.50 - 30 Conducted Limit (dBµV) Quai-peak Average 66 to 56 56 to 46 56 46 60 50 5.6.2 Test Setup See section 4.5.2 for test setup description for the AC power supply port. The photo of test setup please refer to ANNEX B. 5.6.3 Test Procedure The maximum conducted interference is searched using Peak (PK), if the emission levels more than the AV and QP limits, and that have narrow margins from the AV and QP limits will be re-measured with AV and QP detectors. Tests for both L phase and N phase lines of the power mains connected to the EUT are performed. Refer to recorded points and plots below. Devices subject to Part 15 must be tested for all available U.S. voltages and frequencies (such as a nominal 120 VAC, 50/60 Hz and 240 VAC, 50/60 Hz) for which the device is capable of operation. A device rated for 50/60 Hz operation need not be tested at both frequencies provided the radiated and line conducted emissions are the same at both frequencies. 5.6.4 Test Result Please refer to ANNEX A.5. Tel: +86-755-66850100 E-mail: [email protected] Page No. 21 / 73 Web: www.titcgroup.com Template No.: TRP-FCC&ISED 247 (2022-01-12) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Report No.: BL-SZ2430252-601 5.7 Radiated Spurious Emission 5.7.1 Limit FCC §15.209&15.247(d); RSS-GEN, 8.9; RSS-247, 5.5 Radiated emission outside the frequency band attenuation below the general limits specified in FCC section 15.209(a) is not required. In addition, radiated emissions which fall in the restricted bands, as defined in FCC section 15.205(a), must also comply with the radiated emission limits specified in FCC section 15.209(a). According to FCC section 15.209 (a), except as provided elsewhere in this subpart, the emissions from an intentional radiator shall not exceed the field strength levels specified in the following table: Frequency (MHz) 0.009 - 0.490 0.490 - 1.705 1.705 - 30.0 30 - 88 88 - 216 216 - 960 Above 960 Field Strength (µV/m) 2400/F(kHz) 24000/F(kHz) 30 100 150 200 500 Measurement Distance (m) 300 30 30 3 3 3 3 Note: 1. Field Strength (dBµV/m) = 20*log[Field Strength (µV/m)]. 2. In the emission tables above, the tighter limit applies at the band edges. 3. For Above 1000 MHz, the emission limit in this paragraph is based on measurement instrumentation employing an average detector, measurement using instrumentation with a peak detector function, corresponding to 20dB above the maximum permitted average limit. 4. For above 1000 MHz, limit field strength of harmonics: 54dBuV/m@3m (AV) and 74dBuV/m@3m (PK). 5.7.2 Test Setup See section 4.5.3 to 4.5.5 for test setup description for the antenna port. The photo of test setup please refer to ANNEX B. 5.7.3 Test Procedure Since the emission limits are specified in terms of radiated field strength levels, measurements performed to demonstrate compliance have traditionally relied on a radiated test configuration. Radiated measurements remain the principal method for demonstrating compliance to the specified limits; however antenna-port conducted measurements are also now acceptable to demonstrate compliance (see below for details). When radiated measurements are utilized, test site requirements and procedures for maximizing and measuring radiated emissions that are described in ANSI C63.10 shall be followed. Antenna-port conducted measurements may also be used as an alternative to radiated measurements Tel: +86-755-66850100 E-mail: [email protected] Page No. 22 / 73 Web: www.titcgroup.com Template No.: TRP-FCC&ISED 247 (2022-01-12) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Report No.: BL-SZ2430252-601 for demonstrating compliance in the restricted frequency bands. If conducted measurements are performed, then proper impedance matching must be ensured and an additional radiated test for cabinet/case spurious emissions is required. General Procedure for conducted measurements in restricted bands: a) Measure the conducted output power (in dBm) using the detector specified (see guidance regarding measurement procedures for determining quasi-peak, peak, and average conducted output power, respectively). b) Add the maximum transmit antenna gain (in dBi) to the measured output power level to determine the EIRP level (see guidance on determining the applicable antenna gain) c) Add the appropriate maximum ground reflection factor to the EIRP level (6 dB for frequencies 30 MHz, 4.7 dB for frequencies between 30 MHz and 1000 MHz, inclusive and 0 dB for frequencies > 1000 MHz). d) For devices with multiple antenna-ports, measure the power of each individual chain and sum the EIRP of all chains in linear terms (e.g., Watts, mW). e) Convert the resultant EIRP level to an equivalent electric field strength using the following relationship: E = EIRP 20log D + 104.8 where: E = electric field strength in dBV/m, EIRP = equivalent isotropic radiated power in dBm D = specified measurement distance in meters. f) Compare the resultant electric field strength level to the applicable limit. g) Perform radiated spurious emission test. Quasi-Peak measurement procedure The specifications for measurements using the CISPR quasi-peak detector can be found in Publication 16 of the International Special Committee on Radio Frequency Interference (CISPR) of the International Electrotechnical Commission. As an alternative to CISPR quasi-peak measurement, compliance can be demonstrated to the applicable emission limits using a peak detector. Peak power measurement procedure: Peak emission levels are measured by setting the instrument as follows: a) RBW = as specified in Table 1. b) VBW 3 x RBW. Tel: +86-755-66850100 E-mail: [email protected] Page No. 23 / 73 Web: www.titcgroup.com Template No.: TRP-FCC&ISED 247 (2022-01-12) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Report No.: BL-SZ2430252-601 c) Detector = Peak. d) Sweep time = auto. e) Trace mode = max hold. f) Allow sweeps to continue until the trace stabilizes. (Note that the required measurement time may be longer for low duty cycle applications). Table 1--RBW as a function of frequency Frequency 9-150 kHz 0.15-30 MHz 30-1000 MHz > 1000 MHz RBW 200-300 Hz 9-10 kHz 100-120 kHz 1 MHz If the peak-detected amplitude can be shown to comply with the average limit, then it is not necessary to perform a separate average measurement. Trace averaging across on and off times of the EUT transmissions followed by duty cycle correction: If continuous transmission of the EUT (i.e., duty cycle 98 percent) cannot be achieved and the duty cycle is constant (i.e., duty cycle variations are less than ± 2 percent), then the following procedure shall be used: a) The EUT shall be configured to operate at the maximum achievable duty cycle. b) Measure the duty cycle, x, of the transmitter output signal as described in section 6.0. c) RBW = 1 MHz (unless otherwise specified). d) VBW 3 x RBW. e) Detector = RMS, if span/(# of points in sweep) (RBW/2). Satisfying this condition may require increasing the number of points in the sweep or reducing the span. If this condition cannot be satisfied, then the detector mode shall be set to peak. f) Averaging type = power (i.e., RMS). 1) As an alternative, the detector and averaging type may be set for linear voltage averaging. 2) Some instruments require linear display mode in order to use linear voltage averaging. Log or dB averaging shall not be used. g) Sweep time = auto. h) Perform a trace average of at least 100 traces. i) A correction factor shall be added to the measurement results prior to comparing to the emission limit in order to compute the emission level that would have been measured had the test been performed at 100 percent duty cycle. The correction factor is computed as follows: Tel: +86-755-66850100 E-mail: [email protected] Page No. 24 / 73 Web: www.titcgroup.com Template No.: TRP-FCC&ISED 247 (2022-01-12) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Report No.: BL-SZ2430252-601 1) If power averaging (RMS) mode was used in step f), then the applicable correction factor is 10 log(1/x), where x is the duty cycle. 2) If linear voltage averaging mode was used in step f), then the applicable correction factor is 20 log(1/x), where x is the duty cycle. 3) If a specific emission is demonstrated to be continuous ( 98 percent duty cycle) rather than turning on and off with the transmit cycle, then no duty cycle correction is required for that emission. NOTE: Reduction of the measured emission amplitude levels to account for operational duty factor is not permitted. Compliance is based on emission levels occurring during transmission - not on an average across on and off times of the transmitter. Determining the applicable transmit antenna gain: A conducted power measurement will determine the maximum output power associated with a restricted band emission; however, in order to determine the associated EIRP level, the gain of the transmitting antenna (in dBi) must be added to the measured output power (in dBm). Since the out-of-band characteristics of the EUT transmit antenna will often be unknown, the use of a conservative antenna gain value is necessary. Thus, when determining the EIRP based on the measured conducted power, the upper bound on antenna gain for a device with a single RF output shall be selected as the maximum in-band gain of the antenna across all operating bands, or 2 dBi, whichever is greater. However, for devices that operate in multiple frequency bands while using the same transmit antenna, the highest gain of the antenna within the operating band nearest in frequency to the restricted band emission being measured may be used in lieu of the overall highest gain when the emission is at a frequency that is within 20 percent of the nearest band edge frequency, but in no case shall a value less than 2 dBi be used. See KDB 662911 for guidance on calculating the additional array gain term when determining the effective antenna gain for a EUT with multiple outputs occupying the same or overlapping frequency ranges in the same band. Radiated spurious emission test: An additional consideration when performing conducted measurements of restricted band emissions is that unwanted emissions radiating from the EUT cabinet, control circuits, power leads, or intermediate circuit elements will likely go undetected in a conducted measurement configuration. To address this concern, a radiated test shall be performed to ensure that emissions emanating from the EUT cabinet (rather than the antenna port) also comply with the applicable limits. For these cabinet radiated spurious emission measurements the EUT transmit antenna may be replaced with a termination matching the nominal impedance of the antenna. Procedures for performing radiated measurements are specified in ANSI C63.10. All detected emissions shall comply with the applicable limits. The measurement frequency range is from 30MHz to the 10th harmonic of the fundamental frequency. The Turn Table is actuated to turn from 0° to 360°, and both horizontal and vertical polarizations of the Tel: +86-755-66850100 E-mail: [email protected] Page No. 25 / 73 Web: www.titcgroup.com Template No.: TRP-FCC&ISED 247 (2022-01-12) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Report No.: BL-SZ2430252-601 Test Antenna are used to find the maximum radiated power. Mid channels on all channel bandwidth verified. Only the worst RB size/offset presented. The power of the EUT transmitting frequency should be ignored. All Spurious Emission tests were performed in X, Y, Z axis direction. And only the worst axis test condition was recorded in this test report. Use the following spectrum analyzer settings: Span = wide enough to fully capture the emission being measured RBW = 1 MHz for f 1 GHz, 100 kHz for f < 1 GHz VBW RBW Sweep = auto Detector function = peak Trace = max hold 5.7.4 Test Result Please refer to ANNEX A.6. Tel: +86-755-66850100 E-mail: [email protected] Page No. 26 / 73 Web: www.titcgroup.com Template No.: TRP-FCC&ISED 247 (2022-01-12) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Report No.: BL-SZ2430252-601 5.8 Band Edge (Restricted-band band-edge) 5.8.1 Limit FCC §15.209&15.247(d); RSS-GEN, 8.10; RSS-247, 5.5 Radiated emission outside the frequency band attenuation below the general limits specified in FCC section 15.209(a) is not required. In addition, radiated emissions which fall in the restricted bands, as defined in FCC section 15.205(a), must also comply with the radiated emission limits specified in FCC section 15.209(a). 5.8.2 Test Setup See section 4.5.3 to 4.5.5 for test setup description for the antenna port. The photo of test setup please refer to ANNEX B. 5.8.3 Test Procedure The measurement frequency range is from 9 kHz to the 10th harmonic of the fundamental frequency. The Turn Table is actuated to turn from 0° to 360°, and both horizontal and vertical polarizations of the Test Antenna are used to find the maximum radiated power. Mid channels on all channel bandwidth verified. Only the worst RB size/offset presented. The power of the EUT transmitting frequency should be ignored. All Spurious Emission tests were performed in X, Y, Z axis direction. And only the worst axis test condition was recorded in this test report. Use the following spectrum analyzer settings: Span = wide enough to fully capture the emission being measured RBW = 1 MHz for f 1 GHz, 100 kHz for f < 1 GHz VBW RBW Sweep = auto Detector function = peak Trace = max hold For measurement below 1GHz, If the emission level of the EUT measured by the peak detector is 3 dB lower than the applicable limit, the peak emission level will be reported, Otherwise, the emission measurement will be repeated using the quasi-peak detector and reported. For transmitters operating above 1 GHz repeat the measurement with an average detector. 5.8.4 Test Result Please refer to ANNEX A.7. Tel: +86-755-66850100 E-mail: [email protected] Page No. 27 / 73 Web: www.titcgroup.com Template No.: TRP-FCC&ISED 247 (2022-01-12) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Report No.: BL-SZ2430252-601 5.9 Power Spectral density (PSD) 5.9.1 Limit FCC §15.247(e); RSS-247, 5.2 (b) The same method of determining the conducted output power shall be used to determine the power spectral density. If a peak output power is measured, then a peak power spectral density measurement is required. If an average output power is measured, then an average power spectral density measurement should be used. The transmitter power spectral density conducted from the transmitter to the antenna shall not be greater than 8 dBm in any 3 kHz band during any time interval of continuous transmission. This power spectral density shall be determined in accordance with the provisions of Section 5.4(4), (i.e. the power spectral density shall be determined using the same method as is used to determine the conducted output power). 5.9.2 Test Setup See section 4.5.1 (Diagram 1) for test setup description for the antenna port. The photo of test setup please refer to ANNEX B. 5.9.3 Test Procedure Set analyzer center frequency to DTS channel center frequency. Set the span to 1.5 times the DTS bandwidth. Set the RBW to: 3 kHz RBW 100 kHz. Set the VBW 3 RBW. Detector = peak. Sweep time = auto couple. Trace mode = max hold. Allow trace to fully stabilize. Use the peak marker function to determine the maximum amplitude level within the RBW. If measured value exceeds limit, reduce RBW (no less than 3 kHz) and repeat. 5.9.4 Test Result Please refer to ANNEX A.8. Tel: +86-755-66850100 E-mail: [email protected] Page No. 28 / 73 Web: www.titcgroup.com Template No.: TRP-FCC&ISED 247 (2022-01-12) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Report No.: BL-SZ2430252-601 ANNEX A TEST RESULT A.1 Output Power, E.I.R.P, Duty Cycle Peak Power Test Data Measured Output Peak Power Channel GFSK (BLE 1Mbps) dBm mW Low Channel -0.34 0.93 Middle Channel 0.13 1.03 High Channel 0.24 1.06 Channel Low Channel Middle Channel High Channel Measured Output Peak Power GFSK (BLE 2Mbps) dBm mW -0.05 0.99 0.33 1.08 0.41 1.10 Limit dBm mW 30 1000 Limit dBm mW 30 1000 E.I.R.P Test Data (For ISED) E.I.R.P Channel GFSK (BLE 1Mbps) dBm mW Low Channel 1.45 1.39 Middle Channel 1.91 1.55 High Channel 2.02 1.59 Channel Low Channel Middle Channel High Channel E.I.R.P GFSK (BLE 2Mbps) dBm mW 1.73 1.49 2.11 1.63 2.19 1.65 Limit dBm mW 36 4000 Limit dBm mW 36 4000 Verdict Pass Pass Pass Verdict Pass Pass Pass Verdict Pass Pass Pass Verdict Pass Pass Pass Tel: +86-755-66850100 E-mail: [email protected] Page No. 29 / 73 Web: www.titcgroup.com Template No.: TRP-FCC&ISED 247 (2022-01-12) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Report No.: BL-SZ2430252-601 Test Plots GFSK (BLE 1Mbps) LOW CHANNEL GFSK (BLE 1Mbps) MIDDLE CHANNEL GFSK (BLE 1Mbps) HIGH CHANNEL Tel: +86-755-66850100 E-mail: [email protected] Page No. 30 / 73 Web: www.titcgroup.com Template No.: TRP-FCC&ISED 247 (2022-01-12) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Report No.: BL-SZ2430252-601 GFSK (BLE 2Mbps) LOW CHANNEL GFSK (BLE 2Mbps) MIDDLE CHANNEL GFSK (BLE 2Mbps) HIGH CHANNEL Tel: +86-755-66850100 E-mail: [email protected] Page No. 31 / 73 Web: www.titcgroup.com Template No.: TRP-FCC&ISED 247 (2022-01-12) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Report No.: BL-SZ2430252-601 Duty Cycle Test Data Band GFSK (BLE 1Mbps) GFSK (BLE 2Mbps) On Time (ms) 10.06 10.06 Test Plots On+Off Time (ms) 10.06 10.06 Duty Cycle 100.00% 100.00% Tel: +86-755-66850100 E-mail: [email protected] Page No. 32 / 73 Web: www.titcgroup.com Template No.: TRP-FCC&ISED 247 (2022-01-12) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Report No.: BL-SZ2430252-601 A.2 Occupied Bandwidth Test Data Test Mode Channel Low Channel Middle Channel High Channel Test Mode Channel Low Channel Middle Channel High Channel 6 dB Bandwidth (kHz) 710.000 750.000 800.000 6 dB Bandwidth (kHz) 1320.000 1400.000 1400.000 GFSK (BLE 1Mbps) 99% Bandwidth (kHz) 1041.400 1054.700 1118.000 GFSK (BLE 2Mbps) 99% Bandwidth (kHz) 2013.400 2071.300 2076.900 6 dB Bandwidth Limits (kHz) 500 500 500 6 dB Bandwidth Limits (kHz) 500 500 500 Tel: +86-755-66850100 E-mail: [email protected] Page No. 33 / 73 Web: www.titcgroup.com Template No.: TRP-FCC&ISED 247 (2022-01-12) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Report No.: BL-SZ2430252-601 Test Plots 6 dB Bandwidth GFSK (BLE 1Mbps) LOW CHANNEL GFSK (BLE 1Mbps) MIDDLE CHANNEL GFSK (BLE 1Mbps) HIGH CHANNEL GFSK (BLE 2Mbps) LOW CHANNEL GFSK (BLE 2Mbps) MIDDLE CHANNEL Tel: +86-755-66850100 E-mail: [email protected] Page No. 34 / 73 Web: www.titcgroup.com Template No.: TRP-FCC&ISED 247 (2022-01-12) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Report No.: BL-SZ2430252-601 GFSK (BLE 2Mbps) HIGH CHANNEL 99% Bandwidth GFSK (BLE 1Mbps) LOW CHANNEL GFSK (BLE 1Mbps) MIDDLE CHANNEL GFSK (BLE 1Mbps) HIGH CHANNEL Tel: +86-755-66850100 E-mail: [email protected] Page No. 35 / 73 Web: www.titcgroup.com Template No.: TRP-FCC&ISED 247 (2022-01-12) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Report No.: BL-SZ2430252-601 GFSK (BLE 2Mbps) LOW CHANNEL GFSK (BLE 2Mbps) MIDDLE CHANNEL GFSK (BLE 2Mbps) HIGH CHANNEL Tel: +86-755-66850100 E-mail: [email protected] Page No. 36 / 73 Web: www.titcgroup.com Template No.: TRP-FCC&ISED 247 (2022-01-12) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Report No.: BL-SZ2430252-601 A.3 Conducted Spurious Emissions Test Data Channel Low Channel Middle Channel High Channel Channel Low Channel Middle Channel High Channel Measured Max. Out of Band Emission (dBm) -25.66 -25.99 -26.10 GFSK (BLE 1Mbps) Limit (dBm) Carrier Level Calculated 20 dBc Limit -1.49 -21.49 -1.04 -21.04 -0.94 -20.94 Measured Max. Out of Band Emission (dBm) -27.18 -26.27 -27.74 GFSK (BLE 2Mbps) Limit (dBm) Carrier Level Calculated 20 dBc Limit -2.98 -22.98 -3.01 -23.01 -2.95 -22.95 Verdict Pass Pass Pass Verdict Pass Pass Pass Tel: +86-755-66850100 E-mail: [email protected] Page No. 37 / 73 Web: www.titcgroup.com Template No.: TRP-FCC&ISED 247 (2022-01-12) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Report No.: BL-SZ2430252-601 Test Plots GFSK (BLE 1Mbps) LOW CHANNEL, CARRIER LEVEL GFSK (BLE 1Mbps) LOW CHANNEL, SPURIOUS 30 MHz ~ 3 GHz GFSK (BLE 1Mbps) LOW CHANNEL, SPURIOUS 2 GHz ~ 25 GHz GFSK (BLE 1Mbps) MIDDLE CHANNEL, CARRIER LEVEL Tel: +86-755-66850100 E-mail: [email protected] Page No. 38 / 73 Web: www.titcgroup.com Template No.: TRP-FCC&ISED 247 (2022-01-12) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Report No.: BL-SZ2430252-601 GFSK (BLE 1Mbps) MIDDLE CHANNEL, SPURIOUS 30 MHz ~ 3 GHz GFSK (BLE 1Mbps) MIDDLE CHANNEL, SPURIOUS 2 GHz ~ 25 GHz GFSK (BLE 1Mbps) HIGH CHANNEL, CARRIER LEVEL GFSK (BLE 1Mbps) HIGH CHANNEL, SPURIOUS 30 MHz ~ 3 GHz GFSK (BLE 1Mbps) HIGH CHANNEL, SPURIOUS 2 GHz ~ 25 GHz Tel: +86-755-66850100 E-mail: [email protected] Page No. 39 / 73 Web: www.titcgroup.com Template No.: TRP-FCC&ISED 247 (2022-01-12) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Report No.: BL-SZ2430252-601 GFSK (BLE 2Mbps) LOW CHANNEL, CARRIER LEVEL GFSK (BLE 2Mbps) LOW CHANNEL, SPURIOUS 30 MHz ~ 3 GHz GFSK (BLE 2Mbps) LOW CHANNEL, SPURIOUS 2 GHz ~ 25 GHz GFSK (BLE 2Mbps) MIDDLE CHANNEL, CARRIER LEVEL Tel: +86-755-66850100 E-mail: [email protected] Page No. 40 / 73 Web: www.titcgroup.com Template No.: TRP-FCC&ISED 247 (2022-01-12) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Report No.: BL-SZ2430252-601 GFSK (BLE 2Mbps) MIDDLE CHANNEL, SPURIOUS 30 MHz ~ 3 GHz GFSK (BLE 2Mbps) MIDDLE CHANNEL, SPURIOUS 2 GHz ~ 25 GHz GFSK (BLE 2Mbps) HIGH CHANNEL, CARRIER LEVEL GFSK (BLE 2Mbps) HIGH CHANNEL, SPURIOUS 30 MHz ~ 3 GHz GFSK (BLE 2Mbps) HIGH CHANNEL, SPURIOUS 2 GHz ~ 25 GHz Tel: +86-755-66850100 E-mail: [email protected] Page No. 41 / 73 Web: www.titcgroup.com Template No.: TRP-FCC&ISED 247 (2022-01-12) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Report No.: BL-SZ2430252-601 A.4 Band Edge (Authorized-band band-edge) Note: The lowest and highest channels are tested to verify the band edge emissions. Please refer to the following the plots for emissions values. Test Data GFSK (BLE 1Mbps) Measured Max. Limit (dBm) Channel Band Edge Emission (dBm) Carrier Level Calculated 20 dBc Limit Verdict Low Channel -40.45 -1.49 -21.49 Pass High Channel -46.22 -0.94 -20.94 Pass Channel Low Channel High Channel Measured Max. Band Edge Emission (dBm) -41.10 -45.99 GFSK (BLE 2Mbps) Limit (dBm) Carrier Level Calculated 20 dBc Limit -2.98 -22.98 -2.95 -22.95 Verdict Pass Pass Tel: +86-755-66850100 E-mail: [email protected] Page No. 42 / 73 Web: www.titcgroup.com Template No.: TRP-FCC&ISED 247 (2022-01-12) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Report No.: BL-SZ2430252-601 Test Plots GFSK (BLE 1Mbps) LOW CHANNEL, CARRIER LEVEL GFSK (BLE 1Mbps) LOW CHANNEL, BAND EDGE GFSK (BLE 1Mbps) HIGH CHANNEL, CARRIER LEVEL GFSK (BLE 1Mbps) HIGH CHANNEL, BAND EDGE Tel: +86-755-66850100 E-mail: [email protected] Page No. 43 / 73 Web: www.titcgroup.com Template No.: TRP-FCC&ISED 247 (2022-01-12) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Report No.: BL-SZ2430252-601 GFSK (BLE 2Mbps) LOW CHANNEL, CARRIER LEVEL GFSK (BLE 2Mbps) LOW CHANNEL, BAND EDGE GFSK (BLE 2Mbps) HIGH CHANNEL, CARRIER LEVEL GFSK (BLE 2Mbps) HIGH CHANNEL, BAND EDGE Tel: +86-755-66850100 E-mail: [email protected] Page No. 44 / 73 Web: www.titcgroup.com Template No.: TRP-FCC&ISED 247 (2022-01-12) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Report No.: BL-SZ2430252-601 A.5 Conducted Emissions Note 1: The EUT is working in the Normal link mode. All modes have been tested and normal link mode is worst. Note 2: Devices subject to Part 15 must be tested for all available U.S. voltages and frequencies (such as a nominal 120 VAC, 60 Hz and 240 VAC, 50 Hz) for which the device is capable of operation. So, The configuration 120 VAC, 60 Hz and 240 VAC, 50 Hz were tested respectively, but only the worst configuration (240 VAC, 50 Hz) shown here. Note 3: Results (dBuV) = Original reading level of Spectrum Analyzer (dBuV) + Factor (dB) Test Data and Plots Model Name: PLB108 PHASE L No. Frequency Results (MHz) (dBuV) 1 0.154 52.29 1** 0.154 36.72 2 0.256 45.53 2** 0.256 31.42 3 0.476 44.30 3** 0.476 32.42 4 3.864 47.55 4** 3.864 37.21 5 13.784 46.00 5** 13.784 34.02 6 20.216 48.05 6** 20.216 33.53 Factor (dB) 9.78 9.78 9.77 9.77 10.00 10.00 10.30 10.30 10.72 10.72 10.93 10.93 Limit (dBuV) 65.78 55.78 61.56 51.56 56.41 46.41 56.00 46.00 60.00 50.00 60.00 50.00 Margin (dB) 13.49 19.06 16.03 20.14 12.11 13.99 8.45 8.79 14.00 15.98 11.95 16.47 Detector Line Peak L AV L Peak L AV L Peak L AV L Peak L AV L Peak L AV L Peak L AV L Verdict Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Tel: +86-755-66850100 E-mail: [email protected] Page No. 45 / 73 Web: www.titcgroup.com Template No.: TRP-FCC&ISED 247 (2022-01-12) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Report No.: BL-SZ2430252-601 PHASE N No. Frequency Results (MHz) (dBuV) 1 0.150 51.70 1** 0.150 36.06 2 0.274 45.22 2** 0.274 33.31 3 0.454 45.59 3** 0.454 30.70 4 3.870 47.94 4** 3.870 38.13 5 12.338 44.45 5** 12.338 34.45 6 19.000 46.66 6** 19.000 32.56 Factor (dB) 9.78 9.78 9.76 9.76 10.02 10.02 10.31 10.31 10.61 10.61 10.82 10.82 Limit (dBuV) 66.00 56.00 61.00 51.00 56.80 46.80 56.00 46.00 60.00 50.00 60.00 50.00 Margin (dB) 14.30 19.94 15.78 17.69 11.21 16.10 8.06 7.87 15.55 15.55 13.34 17.44 Detector Line Peak N AV N Peak N AV N Peak N AV N Peak N AV N Peak N AV N Peak N AV N Verdict Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Tel: +86-755-66850100 E-mail: [email protected] Page No. 46 / 73 Web: www.titcgroup.com Template No.: TRP-FCC&ISED 247 (2022-01-12) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Report No.: BL-SZ2430252-601 Model Name: PLB106 PHASE L No. Frequency Results (MHz) (dBuV) 1 0.150 51.21 1** 0.150 37.37 2 0.276 45.43 2** 0.276 33.28 3 1.926 42.33 3** 1.926 28.51 4 3.932 47.27 4** 3.932 36.37 5 12.388 45.71 5** 12.388 33.33 6 19.808 48.29 6** 19.808 34.62 Factor (dB) 9.78 9.78 9.76 9.76 10.42 10.42 10.16 10.16 10.79 10.79 10.79 10.79 Limit (dBuV) 66.00 56.00 60.94 50.94 56.00 46.00 56.00 46.00 60.00 50.00 60.00 50.00 Margin (dB) 14.79 18.63 15.51 17.66 13.67 17.49 8.73 9.63 14.29 16.67 11.71 15.38 Detector Line Peak L AV L Peak L AV L Peak L AV L Peak L AV L Peak L AV L Peak L AV L Verdict Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Tel: +86-755-66850100 E-mail: [email protected] Page No. 47 / 73 Web: www.titcgroup.com Template No.: TRP-FCC&ISED 247 (2022-01-12) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Report No.: BL-SZ2430252-601 PHASE N No. Frequency Results (MHz) (dBuV) 1 0.156 50.81 1** 0.156 35.78 2 0.378 44.65 2** 0.378 32.29 3 0.472 45.39 3** 0.472 33.47 4 4.006 47.90 4** 4.006 37.62 5 18.824 45.97 5** 18.824 32.54 6 26.396 43.50 6** 26.396 31.79 Factor (dB) 9.78 9.78 10.64 10.64 10.01 10.01 10.02 10.02 10.74 10.74 10.78 10.78 Limit (dBuV) 65.67 55.67 58.32 48.32 56.48 46.48 56.00 46.00 60.00 50.00 60.00 50.00 Margin (dB) 14.86 19.89 13.67 16.03 11.09 13.01 8.10 8.38 14.03 17.46 16.50 18.21 Detector Line Peak N AV N Peak N AV N Peak N AV N Peak N AV N Peak N AV N Peak N AV N Verdict Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Tel: +86-755-66850100 E-mail: [email protected] Page No. 48 / 73 Web: www.titcgroup.com Template No.: TRP-FCC&ISED 247 (2022-01-12) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Report No.: BL-SZ2430252-601 A.6 Radiated Spurious Emission Note 1: The symbol of "--" in the table which means not application. Note 2: For the test data above 1 GHz, according the ANSI C63.4-2014, where limits are specified for both average and peak (or quasi-peak) detector functions, if the peak (or quasi-peak) measured value complies with the average limit, it is unnecessary to perform an average measurement. Note 3: The low frequency, which started from 9 kHz to 30 MHz, was pre-scanned and the result which was 20 dB lower than the limit line per 15.31(o) was not reported. Note 4: The EUT is working in the Normal link mode below 1 GHz. All modes have been tested and BLE 2M-High channel mode is the worst. Note 5: Results (dBuV/m) = Original reading level of Spectrum Analyzer (dBuV/m) + Factor (dB) Test Data and Plots Model Name: PLB108 30 MHz to 1 GHz, ANT H No. Frequency Results Factor Limit Margin (MHz) (dBuV/m) (dB) (dBuV/m) (dB) 1 32.037 36.48 -27.39 40.0 3.52 2 83.495 32.17 -30.39 40.0 7.83 3 142.326 35.49 -26.41 43.5 8.01 4 260.860 28.15 -26.56 46.0 17.85 5 322.261 36.54 -23.88 46.0 9.46 6 455.297 36.01 -19.84 46.0 9.99 Detector Peak Peak Peak Peak Peak Peak Table (Degree) 145.00 92.00 254.00 95.00 108.00 236.00 Height (cm) 100 200 200 100 100 200 Antenna Horizontal Horizontal Horizontal Horizontal Horizontal Horizontal Verdict Pass Pass Pass Pass Pass Pass Tel: +86-755-66850100 E-mail: [email protected] Page No. 49 / 73 Web: www.titcgroup.com Template No.: TRP-FCC&ISED 247 (2022-01-12) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Report No.: BL-SZ2430252-601 30 MHz to 1 GHz, ANT V No. Frequency Results Factor Limit Margin (MHz) (dBuV/m) (dB) (dBuV/m) (dB) 1 50.904 35.95 -26.28 40.0 4.05 2 86.406 36.85 -31.00 40.0 3.15 3 88.402 37.54 -30.22 43.5 5.96 4 141.938 33.46 -26.44 43.5 10.04 5 454.472 34.84 -19.84 46.0 11.16 6 682.616 35.82 -15.33 46.0 10.18 Detector Peak Peak Peak Peak Peak Peak Table (Degree) 95.00 131.00 136.00 178.00 181.00 145.00 Height (cm) 100 100 100 100 100 100 Antenna Vertical Vertical Vertical Vertical Vertical Vertical Verdict Pass Pass Pass Pass Pass Pass Tel: +86-755-66850100 E-mail: [email protected] Page No. 50 / 73 Web: www.titcgroup.com Template No.: TRP-FCC&ISED 247 (2022-01-12) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Report No.: BL-SZ2430252-601 Model Name: PLB106 30 MHz to 1 GHz, ANT H No. Frequency Results Factor Limit Margin (MHz) (dBuV/m) (dB) (dBuV/m) (dB) 1 32.182 36.65 -27.39 40.0 3.35 2 84.611 32.16 -30.50 40.0 7.84 3 141.647 35.72 -26.47 43.5 7.78 4 250.432 28.20 -26.79 46.0 17.80 5 327.450 36.29 -23.58 46.0 9.71 6 470.380 35.63 -19.60 46.0 10.37 Detector Peak Peak Peak Peak Peak Peak Table (Degree) 1.00 76.00 254.00 87.00 126.00 223.00 Height (cm) 100 200 200 100 100 200 Antenna Horizontal Horizontal Horizontal Horizontal Horizontal Horizontal Verdict Pass Pass Pass Pass Pass Pass Tel: +86-755-66850100 E-mail: [email protected] Page No. 51 / 73 Web: www.titcgroup.com Template No.: TRP-FCC&ISED 247 (2022-01-12) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Report No.: BL-SZ2430252-601 30 MHz to 1 GHz, ANT V No. Frequency Results Factor Limit Margin (MHz) (dBuV/m) (dB) (dBuV/m) (dB) 1 51.138 34.32 -26.48 40.0 5.68 2 83.883 36.20 -30.30 40.0 3.80 3 87.763 36.59 -30.54 40.0 3.41 4 142.229 33.13 -26.42 43.5 10.37 5 465.918 35.09 -19.62 46.0 10.91 6 619.954 33.27 -15.44 46.0 12.73 Detector Peak Peak Peak Peak Peak Peak Table (Degree) 274.00 334.00 196.00 157.00 203.00 177.00 Height (cm) 100 200 100 100 100 100 Antenna Vertical Vertical Vertical Vertical Vertical Vertical Verdict Pass Pass Pass Pass Pass Pass Tel: +86-755-66850100 E-mail: [email protected] Page No. 52 / 73 Web: www.titcgroup.com Template No.: TRP-FCC&ISED 247 (2022-01-12) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Report No.: BL-SZ2430252-601 Note 1: The marked spikes near 2400 MHz with circle should be ignored because they are Fundamental signal. Note 2: The spurious from 18GHz-25GHz is noise only, do not show on the report. GFSK (BLE 1Mbps) LOW CHANNEL 1 GHz to 18 GHz, ANT H No. Frequency Results Factor Limit Margin (MHz) (dBuV/m) (dB) (dBuV/m) (dB) 1 1595.600 41.99 -16.93 74.0 32.01 1** 1595.600 32.89 -16.93 54.0 21.11 2 2402.200 97.09 -10.59 74.0 -23.09 2** 2402.200 96.70 -10.59 54.0 -42.70 3 4803.500 54.36 -3.36 74.0 19.64 3** 4803.500 49.34 -3.36 54.0 4.66 4 4804.000 53.08 -3.32 74.0 20.92 4** 4804.000 50.99 -3.32 54.0 3.01 5 12530.787 52.51 1.26 74.0 21.49 5** 12530.787 42.80 1.26 54.0 11.20 6 16400.588 55.88 3.16 74.0 18.12 6** 16400.588 46.12 3.16 54.0 7.88 Detector Peak AV Peak AV Peak AV Peak AV Peak AV Peak AV Table (Degree) 240.00 240.00 167.00 167.00 322.00 322.00 158.00 158.00 350.00 350.00 188.00 188.00 Height (cm) 200 200 200 200 150 150 150 150 100 100 100 100 Antenna Horizontal Horizontal Horizontal Horizontal Horizontal Horizontal Horizontal Horizontal Horizontal Horizontal Horizontal Horizontal Verdict Pass Pass N/A N/A Pass Pass Pass Pass Pass Pass Pass Pass Tel: +86-755-66850100 E-mail: [email protected] Page No. 53 / 73 Web: www.titcgroup.com Template No.: TRP-FCC&ISED 247 (2022-01-12) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Report No.: BL-SZ2430252-601 GFSK (BLE 1Mbps) LOW CHANNEL 1 GHz to 18 GHz, ANT V No. Frequency Results Factor Limit Margin (MHz) (dBuV/m) (dB) (dBuV/m) (dB) 1 1330.700 45.87 -17.06 74.0 28.13 1** 1330.700 33.87 -17.06 54.0 20.13 2 2402.300 92.17 -10.58 74.0 -18.17 2** 2402.300 90.99 -10.58 54.0 -36.99 3 4803.750 47.35 -3.36 74.0 26.65 3** 4803.750 42.87 -3.36 54.0 11.13 4 7677.000 53.61 1.01 74.0 20.39 4** 7677.000 44.12 1.01 54.0 9.88 5 12382.113 52.64 1.01 74.0 21.36 5** 12382.113 42.62 1.01 54.0 11.38 6 16413.975 56.17 2.98 74.0 17.83 6** 16413.975 46.19 2.98 54.0 7.81 Detector Peak AV Peak AV Peak AV Peak AV Peak AV Peak AV Table (Degree) 254.00 254.00 203.00 203.00 129.00 129.00 173.00 173.00 242.00 242.00 237.00 237.00 Height (cm) 300 300 100 100 100 100 300 300 400 400 200 200 Antenna Vertical Vertical Vertical Vertical Vertical Vertical Vertical Vertical Vertical Vertical Vertical Vertical Verdict Pass Pass N/A N/A Pass Pass Pass Pass Pass Pass Pass Pass Tel: +86-755-66850100 E-mail: [email protected] Page No. 54 / 73 Web: www.titcgroup.com Template No.: TRP-FCC&ISED 247 (2022-01-12) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Report No.: BL-SZ2430252-601 GFSK (BLE 1Mbps) MIDDLE CHANNEL 1 GHz to 18 GHz, ANT H No. Frequency Results Factor Limit Margin (MHz) (dBuV/m) (dB) (dBuV/m) (dB) 1 1379.600 42.69 -17.18 74.0 31.31 1** 1379.600 32.37 -17.18 54.0 21.63 2 2440.300 96.94 -10.03 74.0 -22.94 2** 2440.300 95.68 -10.03 54.0 -41.68 3 4879.750 52.66 -3.71 74.0 21.34 3** 4879.750 49.06 -3.71 54.0 4.94 4 4880.000 52.46 -3.67 74.0 21.54 4** 4880.000 49.25 -3.67 54.0 4.75 5 11768.651 52.82 -0.18 74.0 21.18 5** 11768.651 43.80 -0.18 54.0 10.20 6 17494.688 56.26 4.74 74.0 17.74 6** 17494.688 45.58 4.74 54.0 8.42 Detector Peak AV Peak AV Peak AV Peak AV Peak AV Peak AV Table (Degree) 112.00 112.00 166.00 166.00 322.00 322.00 322.00 322.00 140.00 140.00 181.00 181.00 Height (cm) 400 400 200 200 100 100 100 100 200 200 400 400 Antenna Horizontal Horizontal Horizontal Horizontal Horizontal Horizontal Horizontal Horizontal Horizontal Horizontal Horizontal Horizontal Verdict Pass Pass N/A N/A Pass Pass Pass Pass Pass Pass Pass Pass Tel: +86-755-66850100 E-mail: [email protected] Page No. 55 / 73 Web: www.titcgroup.com Template No.: TRP-FCC&ISED 247 (2022-01-12) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Report No.: BL-SZ2430252-601 GFSK (BLE 1Mbps) MIDDLE CHANNEL 1 GHz to 18 GHz, ANT V No. Frequency Results Factor Limit Margin (MHz) (dBuV/m) (dB) (dBuV/m) (dB) 1 1330.900 46.10 -16.93 74.0 27.90 1** 1330.900 35.26 -16.93 54.0 18.74 2 2440.300 92.39 -10.03 74.0 -18.39 2** 2440.300 91.65 -10.03 54.0 -37.65 3 4983.250 50.48 -3.40 74.0 23.52 3** 4983.250 40.03 -3.40 54.0 13.97 4 7705.250 54.08 2.03 74.0 19.92 4** 7705.250 45.06 2.03 54.0 8.94 5 12506.325 52.49 1.40 74.0 21.51 5** 12506.325 43.76 1.40 54.0 10.24 6 17425.912 55.69 5.50 74.0 18.31 6** 17425.912 46.46 5.50 54.0 7.54 Detector Peak AV Peak AV Peak AV Peak AV Peak AV Peak AV Table (Degree) 261.00 261.00 209.00 209.00 122.00 122.00 324.00 324.00 97.00 97.00 144.00 144.00 Height (cm) 100 100 150 150 100 100 400 400 300 300 100 100 Antenna Vertical Vertical Vertical Vertical Vertical Vertical Vertical Vertical Vertical Vertical Vertical Vertical Verdict Pass Pass N/A N/A Pass Pass Pass Pass Pass Pass Pass Pass Tel: +86-755-66850100 E-mail: [email protected] Page No. 56 / 73 Web: www.titcgroup.com Template No.: TRP-FCC&ISED 247 (2022-01-12) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Report No.: BL-SZ2430252-601 GFSK (BLE 1Mbps) HIGH CHANNEL 1 GHz to 18 GHz, ANT H No. Frequency Results Factor Limit Margin (MHz) (dBuV/m) (dB) (dBuV/m) (dB) 1 1398.800 42.11 -16.98 74.0 31.89 1** 1398.800 32.56 -16.98 54.0 21.44 2 2480.100 96.76 -11.10 74.0 -22.76 2** 2480.100 96.36 -11.10 54.0 -42.36 3 4959.750 50.59 -3.51 74.0 23.41 3** 4959.750 47.47 -3.51 54.0 6.53 4 4960.750 51.30 -3.50 74.0 22.70 4** 4960.750 45.56 -3.50 54.0 8.44 5 12386.150 52.26 1.03 74.0 21.74 5** 12386.150 42.75 1.03 54.0 11.25 6 16401.113 55.74 3.15 74.0 18.26 6** 16401.113 47.47 3.15 54.0 6.53 Detector Peak AV Peak AV Peak AV Peak AV Peak AV Peak AV Table (Degree) 6.00 6.00 159.00 159.00 324.00 324.00 324.00 324.00 55.00 55.00 176.00 176.00 Height (cm) 300 300 100 100 150 150 200 200 200 200 200 200 Antenna Horizontal Horizontal Horizontal Horizontal Horizontal Horizontal Horizontal Horizontal Horizontal Horizontal Horizontal Horizontal Verdict Pass Pass N/A N/A Pass Pass Pass Pass Pass Pass Pass Pass Tel: +86-755-66850100 E-mail: [email protected] Page No. 57 / 73 Web: www.titcgroup.com Template No.: TRP-FCC&ISED 247 (2022-01-12) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Report No.: BL-SZ2430252-601 GFSK (BLE 1Mbps) HIGH CHANNEL 1 GHz to 18 GHz, ANT V No. Frequency Results Factor Limit Margin (MHz) (dBuV/m) (dB) (dBuV/m) (dB) 1 1330.100 45.90 -16.98 74.0 28.10 1** 1330.100 32.60 -16.98 54.0 21.40 2 2479.800 92.63 -11.14 74.0 -18.63 2** 2479.800 91.87 -11.14 54.0 -37.87 3 4918.500 49.32 -3.58 74.0 24.68 3** 4918.500 39.27 -3.58 54.0 14.73 4 7704.750 53.63 2.00 74.0 20.37 4** 7704.750 45.39 2.00 54.0 8.61 5 12975.750 52.81 1.82 74.0 21.19 5** 12975.750 44.71 1.82 54.0 9.29 6 17430.637 56.15 5.51 74.0 17.85 6** 17430.637 46.55 5.51 54.0 7.45 Detector Peak AV Peak AV Peak AV Peak AV Peak AV Peak AV Table (Degree) 239.00 239.00 210.00 210.00 360.00 360.00 341.00 341.00 258.00 258.00 315.00 315.00 Height (cm) 300 300 100 100 100 100 300 300 200 200 400 400 Antenna Vertical Vertical Vertical Vertical Vertical Vertical Vertical Vertical Vertical Vertical Vertical Vertical Verdict Pass Pass N/A N/A Pass Pass Pass Pass Pass Pass Pass Pass Tel: +86-755-66850100 E-mail: [email protected] Page No. 58 / 73 Web: www.titcgroup.com Template No.: TRP-FCC&ISED 247 (2022-01-12) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Report No.: BL-SZ2430252-601 GFSK (BLE 2Mbps) LOW CHANNEL 1 GHz to 18 GHz, ANT H No. Frequency Results Factor Limit Margin (MHz) (dBuV/m) (dB) (dBuV/m) (dB) 1 1394.400 42.50 -17.04 74.0 31.50 1** 1394.400 32.39 -17.04 54.0 21.61 2 2403.600 97.22 -10.35 74.0 -23.22 2** 2403.600 95.43 -10.35 54.0 -41.43 3 4807.250 54.22 -3.09 74.0 19.78 3** 4807.250 47.83 -3.09 54.0 6.17 4 4809.000 53.05 -3.15 74.0 20.95 4** 4809.000 49.11 -3.15 54.0 4.89 5 12432.224 52.77 1.06 74.0 21.23 5** 12432.224 43.47 1.06 54.0 10.53 6 16415.025 55.77 2.97 74.0 18.23 6** 16415.025 46.61 2.97 54.0 7.39 Detector Peak AV Peak AV Peak AV Peak AV Peak AV Peak AV Table (Degree) 40.00 40.00 168.00 168.00 326.00 326.00 326.00 326.00 135.00 135.00 73.00 73.00 Height (cm) 100 100 100 100 150 150 150 150 200 200 300 300 Antenna Horizontal Horizontal Horizontal Horizontal Horizontal Horizontal Horizontal Horizontal Horizontal Horizontal Horizontal Horizontal Verdict Pass Pass N/A N/A Pass Pass Pass Pass Pass Pass Pass Pass Tel: +86-755-66850100 E-mail: [email protected] Page No. 59 / 73 Web: www.titcgroup.com Template No.: TRP-FCC&ISED 247 (2022-01-12) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Report No.: BL-SZ2430252-601 GFSK (BLE 2Mbps) LOW CHANNEL 1 GHz to 18 GHz, ANT V No. Frequency Results Factor Limit Margin (MHz) (dBuV/m) (dB) (dBuV/m) (dB) 1 1331.900 47.97 -16.94 74.0 26.03 1** 1331.900 33.51 -16.94 54.0 20.49 2 2403.500 92.50 -10.41 74.0 -18.50 2** 2403.500 89.85 -10.41 54.0 -35.85 3 4998.250 49.90 -3.41 74.0 24.10 3** 4998.250 40.51 -3.41 54.0 13.49 4 7161.250 53.94 0.59 74.0 20.06 4** 7161.250 44.71 0.59 54.0 9.29 5 12500.625 52.83 1.44 74.0 21.17 5** 12500.625 43.08 1.44 54.0 10.92 6 16393.762 55.65 2.93 74.0 18.35 6** 16393.762 47.43 2.93 54.0 6.57 Detector Peak AV Peak AV Peak AV Peak AV Peak AV Peak AV Table (Degree) 249.00 249.00 203.00 203.00 163.00 163.00 20.00 20.00 33.00 33.00 358.00 358.00 Height (cm) 200 200 200 200 200 200 100 100 200 200 200 200 Antenna Vertical Vertical Vertical Vertical Vertical Vertical Vertical Vertical Vertical Vertical Vertical Vertical Verdict Pass Pass N/A N/A Pass Pass Pass Pass Pass Pass Pass Pass Tel: +86-755-66850100 E-mail: [email protected] Page No. 60 / 73 Web: www.titcgroup.com Template No.: TRP-FCC&ISED 247 (2022-01-12) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Report No.: BL-SZ2430252-601 GFSK (BLE 2Mbps) MIDDLE CHANNEL 1 GHz to 18 GHz, ANT H No. Frequency Results Factor Limit Margin (MHz) (dBuV/m) (dB) (dBuV/m) (dB) 1 1516.800 42.47 -17.05 74.0 31.53 1** 1516.800 32.78 -17.05 54.0 21.22 2 2440.500 97.09 -9.86 74.0 -23.09 2** 2440.500 95.14 -9.86 54.0 -41.14 3 4879.500 51.65 -3.78 74.0 22.35 3** 4879.500 49.93 -3.78 54.0 4.07 4 4880.000 52.67 -3.67 74.0 21.33 4** 4880.000 47.24 -3.67 54.0 6.76 5 12517.250 53.09 1.34 74.0 20.91 5** 12517.250 44.13 1.34 54.0 9.87 6 16392.449 55.21 2.88 74.0 18.79 6** 16392.449 46.38 2.88 54.0 7.62 Detector Peak AV Peak AV Peak AV Peak AV Peak AV Peak AV Table (Degree) 147.00 147.00 164.00 164.00 324.00 324.00 324.00 324.00 273.00 273.00 113.00 113.00 Height (cm) 400 400 150 150 150 150 150 150 200 200 100 100 Antenna Horizontal Horizontal Horizontal Horizontal Horizontal Horizontal Horizontal Horizontal Horizontal Horizontal Horizontal Horizontal Verdict Pass Pass N/A N/A Pass Pass Pass Pass Pass Pass Pass Pass Tel: +86-755-66850100 E-mail: [email protected] Page No. 61 / 73 Web: www.titcgroup.com Template No.: TRP-FCC&ISED 247 (2022-01-12) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Report No.: BL-SZ2430252-601 GFSK (BLE 2Mbps) MIDDLE CHANNEL 1 GHz to 18 GHz, ANT V No. Frequency Results Factor Limit Margin (MHz) (dBuV/m) (dB) (dBuV/m) (dB) 1 1329.600 46.70 -16.79 74.0 27.30 1** 1329.600 33.18 -16.79 54.0 20.82 2 2440.500 92.32 -9.86 74.0 -18.32 2** 2440.500 90.10 -9.86 54.0 -36.10 3 4981.500 50.28 -3.14 74.0 23.72 3** 4981.500 41.51 -3.14 54.0 12.49 4 7703.250 53.65 1.19 74.0 20.35 4** 7703.250 44.70 1.19 54.0 9.30 5 12511.313 52.84 1.37 74.0 21.16 5** 12511.313 42.94 1.37 54.0 11.06 6 16399.275 55.08 3.14 74.0 18.92 6** 16399.275 46.87 3.14 54.0 7.13 Detector Peak AV Peak AV Peak AV Peak AV Peak AV Peak AV Table (Degree) 258.00 258.00 203.00 203.00 220.00 220.00 0.00 0.00 220.00 220.00 190.00 190.00 Height (cm) 400 400 150 150 150 150 100 100 100 100 200 200 Antenna Vertical Vertical Vertical Vertical Vertical Vertical Vertical Vertical Vertical Vertical Vertical Vertical Verdict Pass Pass N/A N/A Pass Pass Pass Pass Pass Pass Pass Pass Tel: +86-755-66850100 E-mail: [email protected] Page No. 62 / 73 Web: www.titcgroup.com Template No.: TRP-FCC&ISED 247 (2022-01-12) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Report No.: BL-SZ2430252-601 GFSK (BLE 2Mbps) HIGH CHANNEL 1 GHz to 18 GHz, ANT H No. Frequency Results Factor Limit Margin (MHz) (dBuV/m) (dB) (dBuV/m) (dB) 1 1480.900 42.32 -16.72 74.0 31.68 1** 1480.900 32.72 -16.72 54.0 21.28 2 2478.400 97.10 -10.95 74.0 -23.10 2** 2478.400 95.07 -10.95 54.0 -41.07 3 4955.250 52.30 -3.67 74.0 21.70 3** 4955.250 45.34 -3.67 54.0 8.66 4 4955.500 50.08 -3.54 74.0 23.92 4** 4955.500 46.08 -3.54 54.0 7.92 5 12528.412 52.73 1.27 74.0 21.27 5** 12528.412 43.25 1.27 54.0 10.75 6 17204.363 55.63 3.92 74.0 18.37 6** 17204.363 45.41 3.92 54.0 8.59 Detector Peak AV Peak AV Peak AV Peak AV Peak AV Peak AV Table (Degree) 26.00 26.00 166.00 166.00 319.00 319.00 319.00 319.00 108.00 108.00 337.00 337.00 Height (cm) 200 200 150 150 100 100 100 100 400 400 300 300 Antenna Horizontal Horizontal Horizontal Horizontal Horizontal Horizontal Horizontal Horizontal Horizontal Horizontal Horizontal Horizontal Verdict Pass Pass N/A N/A Pass Pass Pass Pass Pass Pass Pass Pass Tel: +86-755-66850100 E-mail: [email protected] Page No. 63 / 73 Web: www.titcgroup.com Template No.: TRP-FCC&ISED 247 (2022-01-12) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Report No.: BL-SZ2430252-601 GFSK (BLE 2Mbps) HIGH CHANNEL 1 GHz to 18 GHz, ANT V No. Frequency Results Factor Limit Margin (MHz) (dBuV/m) (dB) (dBuV/m) (dB) 1 1332.800 44.37 -17.15 74.0 29.63 1** 1332.800 35.83 -17.15 54.0 18.17 2 2478.400 92.68 -10.95 74.0 -18.68 2** 2478.400 91.10 -10.95 54.0 -37.10 3 4875.250 48.93 -3.55 74.0 25.07 3** 4875.250 39.14 -3.55 54.0 14.86 4 7704.750 53.10 2.00 74.0 20.90 4** 7704.750 44.77 2.00 54.0 9.23 5 12534.112 52.56 1.24 74.0 21.44 5** 12534.112 43.13 1.24 54.0 10.87 6 17423.813 56.29 5.49 74.0 17.71 6** 17423.813 46.29 5.49 54.0 7.71 Detector Peak AV Peak AV Peak AV Peak AV Peak AV Peak AV Table (Degree) 263.00 263.00 205.00 205.00 275.00 275.00 0.00 0.00 327.00 327.00 341.00 341.00 Height (cm) 200 200 200 200 150 150 200 200 400 400 100 100 Antenna Vertical Vertical Vertical Vertical Vertical Vertical Vertical Vertical Vertical Vertical Vertical Vertical Verdict Pass Pass N/A N/A Pass Pass Pass Pass Pass Pass Pass Pass Tel: +86-755-66850100 E-mail: [email protected] Page No. 64 / 73 Web: www.titcgroup.com Template No.: TRP-FCC&ISED 247 (2022-01-12) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Report No.: BL-SZ2430252-601 A.7 Band Edge (Restricted-band band-edge) Note 1: The lowest and highest channels are tested to verify the band edge emissions. Please refer to the following the plots for emissions values. Note 2: The test data all are tested in the vertical and horizontal antenna which the trace is max hold. So these plots have shown the worst case. Note 3: According the ANSI C63.10-2013, where limits are specified for both average and peak (or quasipeak) detector functions, if the peak (or quasi-peak) measured value complies with the average limit, it is unnecessary to perform an average measurement. Note 4: The Level (dBuV/m) has been corrected by factor. Test Data and Plots GFSK (BLE 1Mbps) LOW CHANNEL No. Frequency Results Factor Limit Margin (MHz) (dBuV/m) (dB) (dBuV/m) (dB) 1 2322.900 54.99 -1.16 74.0 19.01 1** 2322.900 43.43 -1.16 54.0 10.57 2 2389.950 52.60 -1.82 74.0 21.40 2** 2389.950 42.88 -1.82 54.0 11.12 Detector Peak AV Peak AV Table (Degree) 8.00 8.00 265.00 265.00 Height (cm) 150 150 200 200 Antenna Horizontal Horizontal Horizontal Horizontal Verdict Pass Pass Pass Pass Tel: +86-755-66850100 E-mail: [email protected] Page No. 65 / 73 Web: www.titcgroup.com Template No.: TRP-FCC&ISED 247 (2022-01-12) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Report No.: BL-SZ2430252-601 GFSK (BLE 1Mbps) HIGH CHANNEL No. Frequency Results Factor Limit Margin (MHz) (dBuV/m) (dB) (dBuV/m) (dB) 1 2483.560 56.59 -1.09 74.0 17.41 1** 2483.560 47.10 -1.09 54.0 6.90 2 2484.295 59.06 -1.17 74.0 14.94 2** 2484.295 44.56 -1.17 54.0 9.44 Detector Peak AV Peak AV Table (Degree) 337.00 337.00 341.00 341.00 Height (cm) 100 100 200 200 Antenna Horizontal Horizontal Horizontal Horizontal Verdict Pass Pass Pass Pass Tel: +86-755-66850100 E-mail: [email protected] Page No. 66 / 73 Web: www.titcgroup.com Template No.: TRP-FCC&ISED 247 (2022-01-12) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Report No.: BL-SZ2430252-601 GFSK (BLE 2Mbps) LOW CHANNEL No. Frequency Results Factor Limit Margin (MHz) (dBuV/m) (dB) (dBuV/m) (dB) 1 2332.150 54.92 -1.14 74.0 19.08 1** 2332.150 43.16 -1.14 54.0 10.84 2 2389.950 52.21 -1.82 74.0 21.79 2** 2389.950 42.62 -1.82 54.0 11.38 Detector Peak AV Peak AV Table (Degree) 45.00 45.00 126.00 126.00 Height (cm) 100 100 150 150 Antenna Horizontal Horizontal Horizontal Horizontal Verdict Pass Pass Pass Pass Tel: +86-755-66850100 E-mail: [email protected] Page No. 67 / 73 Web: www.titcgroup.com Template No.: TRP-FCC&ISED 247 (2022-01-12) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Report No.: BL-SZ2430252-601 GFSK (BLE 2Mbps) HIGH CHANNEL No. Frequency Results Factor Limit Margin (MHz) (dBuV/m) (dB) (dBuV/m) (dB) 1 2483.560 54.02 -1.09 74.0 19.98 1** 2483.560 43.71 -1.09 54.0 10.29 2 2494.525 55.33 -0.78 74.0 18.67 2** 2494.525 44.01 -0.78 54.0 9.99 Detector Peak AV Peak AV Table (Degree) 336.00 336.00 207.00 207.00 Height (cm) 100 100 200 200 Antenna Horizontal Horizontal Horizontal Horizontal Verdict Pass Pass Pass Pass Tel: +86-755-66850100 E-mail: [email protected] Page No. 68 / 73 Web: www.titcgroup.com Template No.: TRP-FCC&ISED 247 (2022-01-12) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Report No.: BL-SZ2430252-601 A.8 Power Spectral Density (PSD) Test Data Channel Low Channel Middle Channel High Channel Channel Low Channel Middle Channel High Channel GFSK (BLE 1Mbps) Spectral power density Limit (dBm/3kHz) (dBm/3kHz) -16.23 8 -16.03 8 -14.61 8 GFSK (BLE 2Mbps) Spectral power density Limit (dBm/3kHz) (dBm/3kHz) -19.63 8 -20.23 8 -20.25 8 Verdict Pass Pass Pass Verdict Pass Pass Pass Tel: +86-755-66850100 E-mail: [email protected] Page No. 69 / 73 Web: www.titcgroup.com Template No.: TRP-FCC&ISED 247 (2022-01-12) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Report No.: BL-SZ2430252-601 Test Plots GFSK (BLE 1Mbps) LOW CHANNEL GFSK (BLE 1Mbps) MIDDLE CHANNEL GFSK (BLE 1Mbps) HIGH CHANNEL Tel: +86-755-66850100 E-mail: [email protected] Page No. 70 / 73 Web: www.titcgroup.com Template No.: TRP-FCC&ISED 247 (2022-01-12) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Report No.: BL-SZ2430252-601 GFSK (BLE 2Mbps) LOW CHANNEL GFSK (BLE 2Mbps) MIDDLE CHANNEL GFSK (BLE 2Mbps) HIGH CHANNEL Tel: +86-755-66850100 E-mail: [email protected] Page No. 71 / 73 Web: www.titcgroup.com Template No.: TRP-FCC&ISED 247 (2022-01-12) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Report No.: BL-SZ2430252-601 ANNEX B TEST SETUP PHOTOS Please refer the document "BL-SZ2430252-AR.PDF". ANNEX C EUT EXTERNAL PHOTOS Please refer the document "BL-SZ2430252-AW.PDF". ANNEX D EUT INTERNAL PHOTOS Please refer the document "BL-SZ2430252-AI.PDF". Tel: +86-755-66850100 E-mail: [email protected] Page No. 72 / 73 Web: www.titcgroup.com Template No.: TRP-FCC&ISED 247 (2022-01-12) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Report No.: BL-SZ2430252-601 Statement 1. The laboratory guarantees the scientificity, accuracy and impartiality of the test, and is responsible for all the information in the report, except the information provided by the customer. The customer is responsible for the impact of the information provided on the validity of the results. 2. The report without China inspection body and laboratory Mandatory Approval (CMA) mark has no effect of proving to the society. 3. For the report with CNAS mark or A2LA mark, the items marked with "" are not within the accredited scope. 4. This report is invalid if it is altered, without the signature of the testing and approval personnel, or without the "inspection and testing dedicated stamp" or test report stamp. 5. The test data and results are only valid for the tested samples provided by the customer. 6. This report shall not be partially reproduced without the written permission of the laboratory. 7. Any objection shall be raised to the laboratory within 30 days after receiving the report. --END OF REPORT-- Tel: +86-755-66850100 E-mail: [email protected] Page No. 73 / 73 Web: www.titcgroup.com Template No.: TRP-FCC&ISED 247 (2022-01-12) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China
Related FCC IDs:
- 2AIHFZYPLB108 - Guilin Zhishen Information Technology Co.,Ltd. ZHIYUN MOLUS B300/B500 COB Light [ZYPLB108] 钛和检测认证集团股份有限公司