report
()
wakeyouw
Huawei Technologies Co.,Ltd ARDCM-1PHT ARDCM-1PHT QISARDCM-1PHT QISARDCM1PHT ardcm 1pht
Not Your Device? Search For Manuals or Datasheets below:
File Info : application/pdf, 32 Pages, 713.36KB
Document DEVICE REPORTGetApplicationAttachment.html?id=3178312Test report no. 160900971SHA-003 Page 1 of 32 FCC TEST REPORT for Part 15G No. 160900971SHA-003 Applicant : Huawei Technologies Co.,Ltd Administration Building, Headquarters of Huawei Technologies Co., Ltd., Bantian, Longgang District, Shenzhen, China Manufacturer : Huawei Technologies Co.,Ltd Administration Building, Headquarters of Huawei Technologies Co., Ltd., Bantian, Longgang District, Shenzhen, China Product Name : ARDCM-1PHT Type/Model : ARDCM-1PHT TEST RESULT : PASS SUMMARY The equipment complies with the requirements according to the following standard(s) or specification: 47CFR Part 15 (2015): Radio Frequency Devices (Subpart G) ANSI C63.4 (2014): American National Standard for Methods of Measurement of Radio-Noise Emissions from Low-Voltage Electrical and Electronic Equipment in the Range of 9 kHz to 40 GHz Date of issue: Oct 21, 2016 Prepared by: Reviewed by: Wakeyou Wang (Project Engineer) FCC ID: QISARDCM-1PHT Daniel Zhao (Reviewer) TTRF15g_V1©2015Intertek Description of Test Facility Test report no. 160900971SHA-003 Page 2 of 32 Name: Intertek Testing Services Limited Shanghai Address: Building 86, No. 1198 Qinzhou Rd., North, Shanghai 200233, P.R.China FCC Registration Number: 236597 IC Assigned Code: 2042B-1 Name of contact: Jonny Jing Tel: +86 21 61278271 Fax: +86 21 54262353 FCC ID: QISARDCM-1PHT TTRF15g_V1©2015Intertek Content Test report no. 160900971SHA-003 Page 3 of 32 SUMMARY............................................................................................................................................. 1 1 GENERAL INFORMATION ......................................................................................................4 1.1 Description of Equipment Under Test (EUT)................................................4 1.2 Description of Client......................................................................................5 1.3 Description of Test Facility ...........................................................................5 2 TEST SPECIFICATIONS............................................................................................................6 2.1 Standards or specification ..............................................................................6 2.2 Mode of operation during the test ..................................................................6 2.3 Test software list ............................................................................................6 2.4 Test peripherals list ........................................................................................6 2.5 Instrument list ................................................................................................7 2.6 Test Summary ................................................................................................8 3 CONDUCTED EMISSION...................................................................................................................9 3.1 Limits .............................................................................................................9 3.1.1 Limits for conducted emission of class A device ......................................9 3.1.2 Limits for conducted emission of class B device.......................................9 3.2 Test setup .....................................................................................................10 3.3 Test Setup and Test Procedure.....................................................................11 3.4 Test Protocol ................................................................................................12 4 RADIATED EMISSION .................................................................................................................... 13 4.1 Radiated emission limits ..............................................................................13 4.2 Test Environment.........................................................................................14 4.3 Description of the Test Sites ........................................................................16 4.4 Test Setup and Test Procedure.....................................................................22 4.5 Test Protocol ................................................................................................23 FCC ID: QISARDCM-1PHT TTRF15g_V1©2015Intertek 1 GENERAL INFORMATION Test report no. 160900971SHA-003 Page 4 of 32 1.1 Description of Equipment Under Test (EUT) Product Name Type/Model Description of EUT : ARDCM-1PHT : ARDCM-1PHT : There is one model only. Rating : DC 12V powered by power meter indirectly Modulation : OFDM Number of carriers : 512 Carrier spacing : 24.414kHz Channel bandwidth : 200kHz Notch capability/control : Without such function Power settings/control : -5~7 (7 is the highest power and tested as the worst mode) Duty factor of signal injection Category of EUT : 50% : Class B Operation Frequency range for 15G Sample received date Date of test Power line type FCC ID : 2.5MHz 5.7MHz; 2MHz 12MHz; : Aug 20, 2016 : Aug 20, 2016 Oct 19, 2016 : Medium-voltage low voltage : QISARDCM-1PHT FCC ID: QISARDCM-1PHT TTRF15g_V1©2015Intertek 1.2 Description of Client Test report no. 160900971SHA-003 Page 5 of 32 Applicant : Huawei Technologies Co.,Ltd Administration Building, Headquarters of Huawei Technologies Co., Ltd., Bantian, Longgang District, Shenzhen, China Name of contact : Zhang Xinghai Tel : 8675528970299 Fax : 8675589650226 Email : [email protected] Manufacturer : Huawei Technologies Co.,Ltd Administration Building, Headquarters of Huawei Technologies Co., Ltd., Bantian, Longgang District, Shenzhen, China 1.3 Description of Test Facility Name : Intertek Testing Service Shanghai Address : Building 86, No. 1198 Qinzhou Road(North), Shanghai 200233, P.R. China Telephone : 86 21 61278200 Telefax : 86 21 54262353 In-site location Name : Huawei Technologies Co.,Ltd Address : Manka Science and Technology Park, No 901 Tanglu Road, Shanghai, P.R. China FCC ID: QISARDCM-1PHT TTRF15g_V1©2015Intertek 2 TEST SPECIFICATIONS Test report no. 160900971SHA-003 Page 6 of 32 2.1 Standards or specification 47CFR Part 15 (2015) ANSI C63.4 (2014) FCC-11-160A1 2.2 Mode of operation during the test Within this test report, EUT was tested with modulation and tested under its rating voltage and frequency. 2.3 Test software list Test Items Software / / / / Manufacturer / / Version / / 2.4 Test peripherals list Item No. Name / / / / Band and Model / / Description / / FCC ID: QISARDCM-1PHT TTRF15g_V1©2015Intertek 2.5 Instrument list Test report no. 160900971SHA-003 Page 7 of 32 Selected Instrument EMI Test Receiver Bilog Antenna Loop Antenna Model Manufactory ESPI3 R&S CBL 6112D TESEQ FMZB1516 Schwarzbeck EC no. 101505 25221 1516115 Valid until date 10/29/2016 5/20/2018 5/27/2017 FCC ID: QISARDCM-1PHT TTRF15g_V1©2015Intertek 2.6 Test Summary Test report no. 160900971SHA-003 Page 8 of 32 This report applies to tested sample only. The test results have been compared directly with the limits, and the measurement uncertainty is recorded. This report shall not be reproduced in part without written approval of Intertek Testing Service Shanghai Limited. TEST ITEM Conducted emission Radiated emission FCC REFERANCE 15.611(a), 15.107 15.611(b), 15.109 RESULT NA Pass NOTE Not applied to Access BPL. / Notes: 1: NA =Not Applicable 2: This report is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this report. Only the Client is authorized to permit copying or distribution of this report and then only in its entirety. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test results in this report are relevant only to the sample tested. This report by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program. FCC ID: QISARDCM-1PHT TTRF15g_V1©2015Intertek 3 Conducted emission Test report no. 160900971SHA-003 Page 9 of 32 Test result: NA 3.1 Limits 3.1.1 Limits for conducted emission of class A device Frequency range (MHz) Limits dB(µV) Quasi-peak Average 0.15 ~ 0.5 79 66 0.5 ~ 30 73 60 Note: If the limit for the measurement with the average detector is met when using a receiver with a quasi-peak detector, the equipment under test shall be deemed to meet both limits and the measurement using the receiver with an average detector need not be carried out. 3.1.2 Limits for conducted emission of class B device Frequency range (MHz) Limits dB(µV) Quasi-peak Average 0.15 ~ 0.5 0.5 ~ 5 5 ~ 30 66 ~ 56 * 56 60 56 ~ 46 * 46 50 Note: 1. * Means the limit decreasing linearly with the logarithm of the frequency in the range 0.15MHz to 0.5MHz 2. If the limit for the measurement with the average detector is met when using a receiver with a quasi-peak detector, the equipment under test shall be deemed to meet both limits and the measurement using the receiver with an average detector need not be carried out. FCC ID: QISARDCM-1PHT TTRF15g_V1©2015Intertek 3.2 Test setup For table top equipment Test report no. 160900971SHA-003 Page 10 of 32 For floor standing equipment FCC ID: QISARDCM-1PHT TTRF15g_V1©2015Intertek Test report no. 160900971SHA-003 Page 11 of 32 3.3 Test Setup and Test Procedure Measurement was performed in shielded room, and instruments used were following clause 4 and clause 5 of ANSI 63.4. Detailed test procedure was following clause 7.3 of ANSI 63.4. EUT arrangement and operation conditions were according to clause 6 and clause 7 of ANSI 63.4. Frequency range 150kHz 30MHz was checked and EMI receiver measurement bandwidth was set to 9 kHz. FCC ID: QISARDCM-1PHT TTRF15g_V1©2015Intertek 3.4 Test Protocol Temperature : °C Relative Humidity : % Test report no. 160900971SHA-003 Page 12 of 32 L line Test Data: Frequency (MHz) level dB(µV) Quasi-peak Limit dB(µV) Margin (dB) Average level limit Margin dB(µV) dB(µV) (dB) N line: Test Data: Frequency (MHz) level dB(µV) Quasi-peak Limit dB(µV) Margin (dB) Average level limit Margin dB(µV) dB(µV) (dB) Notes: All possible modes of operation were investigated. Only the worst case emissions was measured. FCC ID: QISARDCM-1PHT TTRF15g_V1©2015Intertek 4 Radiated emission Test result: Pass Test report no. 160900971SHA-003 Page 13 of 32 4.1 Radiated emission limits Frequency (MHz) Permitted limit in dBµV/m (Quasi-peak) of Measurement Distance 30m 0.0090.490 107.6-20lg (FkHz) 0.4901.705 87.6-20lg (FkHz) 1.70530.0 29.5 Note: for the measurement distance other than 30m, the limit is varied according to 40dB/10 decades. Frequency (MHz) Permitted limit in dBµV/m (Quasi-peak) of Measurement Distance 3m 30 88 40.0 88 216 43.5 216 960 46.0 Above 960 54.0 Note: for the measurement distance other than 3m, the limit is varied according to 20dB/10 decades. FCC ID: QISARDCM-1PHT TTRF15g_V1©2015Intertek Test report no. 160900971SHA-003 Page 14 of 32 4.2 Test Environment Measurement Principles for Access BPL on Overhead Line Installations (1) Measurements should normally be performed at the horizontal reference distance as specified in Sections 15.209 and 15.109 of the rules (i.e., 30 meters for frequencies below 30 MHz and 10 meters for frequencies 30-88MHz.) If necessary, due to ambient emissions, for frequencies below 30 MHz, measurements may be performed at a closer distance such as 10 meters (or 3 meters if necessary for safety or because measurements cannot practically be performed at 30 meters or 10 meters) from the overhead line. Distance corrections are to be made in accordance with paragraph (4), below. (2) Testing shall be performed at distances of 0, 1/4, 1/2, 3/4 and 1 wavelength down the line from the BPL injection point on the power line. Wavelength spacing is based on the mid-band frequency used by the EUT. In addition, if the mid-band frequency exceeds the lowest frequency injected onto the power line by more than a factor of two, testing shall be extended in steps of 1/2 wavelength of the mid-band frequency until the distance equals or exceeds 1/2 wavelength of the lowest frequency injected. (For example, if the device injects frequencies from 3 to 27 MHz, the wavelength corresponding to the mid-band frequency of 15 MHz is 20 meters, and wavelength corresponding to the lowest injected frequency is 100 meters. Measurements are to be performed at 0, 5, 10, 15, and 20 meters down line--corresponding to zero to one wavelength at the mid-band frequency. Because the mid-band frequency exceeds the minimum frequency by more than a factor of two, additional measurements are required at 10-meter intervals until the distance down-line from the injection point equals or exceeds 1/2 of 100 meters. Thus, additional measurement points are required at 30, 40, and 50 meters down line from the injection point.) (3) Testing shall be repeated for each Access BPL component (injector, extractor, repeater, booster, concentrator, etc.) (4) The distance correction used to calculate the applicable extrapolated emission levels for the measurements that are closer than the specified reference distance in Section 15.209 of the rules shall be based on the slant-range distance, which is the diagonal distance from the center of the measurement antenna to the nearest point of the overhead power line carrying the BPL signals being measured, as defined in Section 15.3(hh) of the rules. Calculations of the slant-range distance and the applicable extrapolated emission levels are made according to Equations (1) and (2) in Section 6, below. (5) For Access BPL devices operating below 30 MHz, if the site-specific alternative extrapolation method is selected, the extrapolation factor is determined by fitting a straight line to measurements of field strength in dBµV/m vs. logarithmic distance in meters from the nearest conductor carrying BPL emissions. Site-specific determination of the extrapolation factor is not permitted for BPL devices that inject signals on the neutral/grounded line of a power system if a grounding conductor (typically located at each pole) is located within 30 meters of any of the measurement locations. a. Measurements shall be made for at least four horizontal distances from the overhead line, at no less than 3 meters from the lateral plane and differing from each FCC ID: QISARDCM-1PHT TTRF15g_V1©2015Intertek Test report no. 160900971SHA-003 Page 15 of 32 other by at least 3 meters. If these measurements allow a straight line with a negative slope to be calculated or drawn with reasonable fit (the minimum regression coefficient of multiple correlation would be 0.9), the best straight line fit would be used to calculate field strength at the 30-meter standard measurement distance in the rules. b. If the four measurements do not satisfy the regression coefficient requirement specified above, measurements at one or more additional distances shall be added until the regression coefficient is satisfied. If the regression coefficient is not satisfied, a site-specific extrapolation rate may not be used. Measurement Principles for Access BPL in Underground Line Installations (1) Underground line installations are those in which the BPL device is mounted in, or attached to a padmounted transformer housing or a ground-mounted junction box and couples directly only to underground cables. (2) Measurements should normally be performed at the horizontal reference distance as specified in Section 15.209 of the rules (i.e., 30 meters for frequencies below 30 MHz and 10 meters for frequencies 30-88MHz.) If necessary, due to ambient emissions, for frequencies below 30 MHz, measurements may be performed at a closer distance such as 3 meters or 10 meters from the inground transformer. Distance corrections are to be made in accordance with Section 15.31(f) in the rules. (3) Measurements shall be made at positions around the perimeter of the in-ground power transformer where the maximum emissions occur. ANSI C63.4, section 8.1, specifies a minimum of 16 radial angles surrounding the EUT (in-ground transformer that contains the BPL device(s)). If directional radiation patterns are suspected, additional azimuth angles shall be examined. Test setup is showed as below: Overhead power line / Underground power line FCC ID: QISARDCM-1PHT TTRF15g_V1©2015Intertek 4.3 Description of the Test Sites Test report no. 160900971SHA-003 Page 16 of 32 Overhead Line Installation Locations: Frequency band 1: The device injects frequencies at 2.5MHz-5.7MHz; The wavelength of mid-band frequency is 73.2m; The wavelength corresponding to the lowest injected frequency is 120m and no extended test should be conducted. Frequency band 2: The device injects frequencies at 2MHz-12MHz; The wavelength of mid-band frequency is 42.9m; The wavelength corresponding to the lowest injected frequency is 150m and test should be extended to 75m at least in steps of 21.5m. Location 1: See below Frequency band 2.5MHz-5.7MHz Test Point 0 1/4 * 1/2* 3/4 * Frequency band 2MHz-12MHz Test Point 0 1/4 * FCC ID: QISARDCM-1PHT Test Distance down the line from the BPL injection point (m) 0 18.3 36.6 54.9 73.2 Test Distance down the line from the BPL injection point (m) 0 10.7 TTRF15g_V1©2015Intertek 1/2* 3/4 * First step of 21.5m Second steps of 21.5m Location 2: See below Test report no. 160900971SHA-003 Page 17 of 32 21.5 32.2 42.9 64.4 85.9 Frequency band 2.5MHz-5.7MHz Test Point 0 1/4 * 1/2* 3/4 * Test Distance down the line from the BPL injection point (m) 0 18.3 36.6 54.9 73.2 Frequency band 2MHz-12MHz Test Point 0 1/4 * 1/2* 3/4 * First step of 21.5m Second steps of 21.5m Test Distance down the line from the BPL injection point (m) 0 10.7 21.5 32.2 42.9 64.4 85.9 FCC ID: QISARDCM-1PHT TTRF15g_V1©2015Intertek Location 3: See below Test report no. 160900971SHA-003 Page 18 of 32 Frequency band 2.5MHz-5.7MHz Test Point 0 1/4 * 1/2* 3/4 * Test Distance down the line from the BPL injection point (m) 0 18.3 36.6 54.9 73.2 Frequency band 2MHz-12MHz Test Point 0 1/4 * 1/2* 3/4 * First step of 21.5m Second steps of 21.5m Test Distance down the line from the BPL injection point (m) 0 10.7 21.5 32.2 42.9 64.4 85.9 FCC ID: QISARDCM-1PHT TTRF15g_V1©2015Intertek Test report no. 160900971SHA-003 Page 19 of 32 Underground Line Installation Locations: Measurements shall be made at positions of minimum of 16 radial angles surrounding the EUT, namely 0, 22.5o, 45o...337.5 o. Location 1: See below FCC ID: QISARDCM-1PHT TTRF15g_V1©2015Intertek Location 2: See below Test report no. 160900971SHA-003 Page 20 of 32 FCC ID: QISARDCM-1PHT TTRF15g_V1©2015Intertek Location 3: See below Test report no. 160900971SHA-003 Page 21 of 32 FCC ID: QISARDCM-1PHT TTRF15g_V1©2015Intertek 4.4 Test Setup and Test Procedure Test report no. 160900971SHA-003 Page 22 of 32 The measurement was performed in site. The horizontal distance between EUT and receiving antenna is 3 meter for both overhead & underground installation. The required measurement frequency range was checked. The radiated emission was measured using the R&S Test Receiver / Spectrum Analyzer with the resolutions bandwidth set as: RBW =9kHz @ receiver mode (9kHz~30MHz) RBW = 120kHz @ receiver mode (30MHz~1GHz) RBW / VBW = 1MHz / 3MHz @ spectrum mode (>1GHz for PK) if applied; RBW / VBW = 1MHz / 10Hz @ spectrum mode (>1GHz for AV) if applied; Slant factor for lower than 30MHz @ overhead installation: Here Hant = 1m, Hpower_line = 2m, Dh = 3m; Therefore Dslant = (32 + (2-1)2)1/2 = 3.2m; Slant factor = 40lg (30 / 3.2) = 38.9dB Measurement distance factor for lower than 30MHz @ underground installation: Distance factor = 40lg (30 / 3) = 40dB Antenna height factor for higher than 30MHz @ overhead and underground installation (the antenna height is fixed at 1m but not varied from 1m to 4 m): Antenna height factor = -5dB FCC ID: QISARDCM-1PHT TTRF15g_V1©2015Intertek 4.5 Test Protocol Test report no. 160900971SHA-003 Page 23 of 32 2.5MHz-5.7MHz, Overhead location 1 A B C D E F G H I J Test Point (m) Ant. Pol. Freq. (MHz) Reading (dBuV/m) Ant. Factor (dB) Cable loss (dB) Slant factor / Ant height Factor (dB) Net (dBuV/m) Limit (dBuV/m) Margin (dBuV/m) 18.3 X 2.47 37.93 19.20 0.06 38.90 18.29 29.50 11.21 36.6 X 3.294 37.63 19.20 0.07 38.90 18.00 29.50 11.50 54.9 X 6.602 39.50 19.20 0.11 38.90 19.91 29.50 9.59 73.2 X 7.222 36.42 19.20 0.11 38.90 16.83 29.50 12.67 73.2 X 3.25 38.10 19.20 0.07 38.90 18.47 29.50 11.03 73.2 X 4.998 39.32 19.20 0.10 38.90 19.72 29.50 9.78 0 Y 3.082 37.67 19.20 0.07 38.90 18.04 29.50 11.46 0 Y 5.226 33.04 19.20 0.10 38.90 13.44 29.50 16.06 0 Y 6.602 36.44 19.20 0.11 38.90 16.85 29.50 12.65 36.6 Y 1.874 32.99 19.20 0.05 38.90 13.34 29.50 16.16 36.6 Y 7.27 40.79 19.20 0.11 38.90 21.20 29.50 8.30 54.9 Y 0.306 46.15 18.90 0.02 38.90 26.17 29.50 3.33 54.9 Y 1.358 39.79 19.20 0.05 38.90 20.14 29.50 9.36 73.2 Y 0.506 39.64 18.90 0.03 38.90 19.67 29.50 9.83 73.2 Y 7.794 33.06 19.20 0.12 38.90 13.48 29.50 16.02 0 H 39.08 19.39 13.61 0.29 -5.00 38.29 40.00 1.71 0 H 146.2 22.41 8.33 0.59 -5.00 36.33 43.50 7.17 0 H 255.08 18.20 12.39 0.77 -5.00 36.36 46.00 9.64 18.3 H 171 26.15 8.95 0.63 -5.00 40.73 43.50 2.77 18.3 H 383.6 20.31 15.79 0.95 -5.00 42.05 46.00 3.95 36.6 H 199.76 23.41 10.78 0.67 -5.00 39.86 43.50 3.64 36.6 H 488.16 16.50 17.53 1.06 -5.00 40.09 46.00 5.91 54.9 H 188.68 25.39 10.01 0.65 -5.00 41.05 43.50 2.45 54.9 H 367.68 18.02 15.30 0.94 -5.00 39.26 46.00 6.74 54.9 H 383.6 22.49 15.79 0.95 -5.00 44.23 46.00 1.77 73.2 H 827.52 16.38 21.89 1.34 -5.00 44.61 46.00 1.39 0 V 42.84 19.95 0.30 13.90 -5.00 39.15 40.00 0.85 18.3 V 298 15.93 0.88 13.16 -5.00 34.97 46.00 11.03 36.6 V 40.84 17.38 13.90 0.29 -5.00 36.57 40.00 3.43 36.6 V 43.44 16.84 13.90 0.30 -5.00 36.04 40.00 3.96 54.9 V 47.76 16.69 13.90 0.32 -5.00 35.91 40.00 4.09 73.2 V 462.56 16.02 17.18 1.03 -5.00 39.23 46.00 6.77 Note 1: H = D + E + F G; J = I-H Note 2: the QP detector is applied based on that the pulse-repetition frequency of assessed signal is higher than 20 Hz. FCC ID: QISARDCM-1PHT TTRF15g_V1©2015Intertek Test report no. 160900971SHA-003 Page 24 of 32 2.5MHz-5.7MHz, Overhead location 2 A B C D E F G H I J Test Point (m) Ant. Pol. Freq. (MHz) Reading (dBuV/m) Ant. Factor (dB) Cable loss (dB) Slant factor / Ant height Factor (dB) Net (dBuV/m) Limit (dBuV/m) Margin (dBuV/m) 0 X 0.438 46.90 18.90 0.03 38.90 26.93 29.50 2.57 18.3 X 2.222 30.80 19.20 0.06 38.90 11.16 29.50 18.34 18.3 X 2.538 33.25 19.20 0.06 38.90 13.61 29.50 15.89 36.6 X 1.594 41.88 19.20 0.05 38.90 22.23 29.50 7.27 54.9 X 3.922 36.68 19.20 0.08 38.90 17.06 29.50 12.44 73.2 X 0.564 43.38 18.92 0.03 38.90 23.43 29.50 6.07 73.2 X 7.121 30.70 19.20 0.11 38.90 11.11 29.50 18.39 0 Y 3.318 42.23 19.20 0.07 38.90 22.60 29.50 6.90 18.3 Y 0.466 45.91 18.90 0.03 38.90 25.94 29.50 3.56 36.6 Y 2.466 31.75 19.20 0.06 38.90 12.11 29.50 17.39 54.9 Y 3.738 38.54 19.20 0.08 38.90 18.92 29.50 10.58 54.9 Y 2.587 35.39 19.20 0.06 38.90 15.75 29.50 13.75 73.2 Y 0.46 44.94 18.90 0.03 38.90 24.97 29.50 4.53 73.2 Y 1.302 38.31 19.20 0.04 38.90 18.65 29.50 10.85 73.2 Y 2.696 31.98 19.20 0.07 38.90 12.35 29.50 17.15 0 H 38.86 20.61 13.55 0.29 -5.00 39.45 40.00 0.55 0 H 82.84 23.87 8.25 0.44 -5.00 37.56 40.00 2.44 0 H 166.56 21.16 8.73 0.62 -5.00 35.51 43.50 7.99 18.3 H 250 19.02 12.30 0.76 -5.00 37.08 46.00 8.92 18.3 H 284.16 17.98 12.91 0.85 -5.00 36.74 46.00 9.26 36.6 H 310 20.30 13.51 0.90 -5.00 39.71 46.00 6.29 36.6 H 446.24 18.47 16.95 1.01 -5.00 41.43 46.00 4.57 73.2 H 38.16 21.22 13.33 0.28 -5.00 39.83 40.00 0.17 0 V 36.8 20.71 12.91 0.28 -5.00 38.90 40.00 1.10 0 V 153.23 23.72 8.37 0.60 -5.00 37.69 43.50 5.81 18.3 V 180 20.02 9.40 0.64 -5.00 35.06 43.50 8.44 18.3 V 270.04 19.64 12.66 0.81 -5.00 38.11 46.00 7.89 36.6 V 340.04 17.11 14.44 0.93 -5.00 37.48 46.00 8.52 36.6 V 591.4 13.16 19.35 1.13 -5.00 38.64 46.00 7.36 54.9 V 250.1 18.91 12.30 0.76 -5.00 36.97 46.00 9.03 73.2 V 36.54 19.78 12.83 0.28 -5.00 37.89 40.00 2.11 73.2 V 458.63 15.35 17.12 1.03 -5.00 38.50 46.00 7.50 Note 1: H = D + E + F G; J = I-H Note 2: the QP detector is applied based on that the pulse-repetition frequency of assessed signal is higher than 20 Hz. FCC ID: QISARDCM-1PHT TTRF15g_V1©2015Intertek Test report no. 160900971SHA-003 Page 25 of 32 2.5MHz-5.7MHz, Overhead location 3 A B C D E F G H I J Test Point (m) Ant. Pol. Freq. (MHz) Reading (dBuV/m) Ant. Factor (dB) Cable loss (dB) Slant factor / Ant height Factor (dB) Net (dBuV/m) Limit (dBuV/m) Margin (dBuV/m) 0 X 1.078 35.97 19.20 0.04 38.90 16.31 29.50 13.19 0 X 1.522 42.41 19.20 0.05 38.90 22.76 29.50 6.74 18.3 X 3.482 34.00 19.20 0.08 38.90 14.38 29.50 15.12 36.6 X 4.892 31.66 19.20 0.10 38.90 12.06 29.50 17.44 36.6 X 5.678 31.00 19.20 0.10 38.90 11.40 29.50 18.10 54.9 X 2.67 37.54 19.20 0.07 38.90 17.91 29.50 11.59 54.9 X 3.454 33.99 19.20 0.08 38.90 14.37 29.50 15.13 73.2 X 1.025 43.10 19.20 0.04 38.90 23.44 29.50 6.06 73.2 X 2.659 39.39 19.20 0.06 38.90 19.75 29.50 9.75 0 Y 3.986 37.47 19.20 0.08 38.90 17.85 29.50 11.65 0 Y 4.45 37.62 19.20 0.09 38.90 18.01 29.50 11.49 18.3 Y 5.67 31.62 19.20 0.10 38.90 12.02 29.50 17.48 18.3 Y 7.518 35.42 19.20 0.12 38.90 15.84 29.50 13.66 36.6 Y 5.006 41.29 19.20 0.10 38.90 21.69 29.50 7.81 54.9 Y 7.274 38.20 19.20 0.11 38.90 18.61 29.50 10.89 0 H 34.8 18.09 12.29 0.27 -5.00 35.65 40.00 4.35 0 H 70.96 20.16 9.69 0.40 -5.00 35.25 40.00 4.75 18.3 H 46.83 17.26 13.90 0.32 -5.00 36.48 40.00 3.52 18.3 H 146.25 26.71 8.33 0.59 -5.00 40.63 43.50 2.87 18.3 H 560.56 14.63 18.79 1.10 -5.00 39.52 46.00 6.48 36.6 H 42.15 20.02 13.90 0.30 -5.00 39.22 40.00 0.78 54.9 H 51.48 18.89 13.60 0.33 -5.00 37.82 40.00 2.18 73.2 H 180.83 21.48 9.46 0.64 -5.00 36.58 43.50 6.92 0 V 46.28 17.73 13.90 0.32 -5.00 36.95 40.00 3.05 0 V 42.78 19.49 13.90 0.30 -5.00 38.69 40.00 1.31 36.6 V 35.69 20.23 12.56 0.27 -5.00 38.06 40.00 1.94 36.6 V 46.54 18.41 13.90 0.32 -5.00 37.63 40.00 2.37 36.6 V 162.5 23.42 8.53 0.62 -5.00 37.57 43.50 5.93 54.9 V 52.1 18.72 13.48 0.34 -5.00 37.54 40.00 2.46 54.9 V 360.85 17.24 15.09 0.94 -5.00 38.27 46.00 7.73 73.2 V 155.66 22.24 8.38 0.61 -5.00 36.23 43.50 7.27 73.2 V 198.99 19.28 10.73 0.67 -5.00 35.68 43.50 7.82 Note 1: H = D + E + F G; J = I-H Note 2: the QP detector is applied based on that the pulse-repetition frequency of assessed signal is higher than 20 Hz. FCC ID: QISARDCM-1PHT TTRF15g_V1©2015Intertek Test report no. 160900971SHA-003 Page 26 of 32 2MHz-12MHz, Overhead location 1 A B C D E F G H I J Test Point (m) Ant. Pol. Freq. (MHz) Reading (dBuV/m) Ant. Factor (dB) Cable loss (dB) Slant factor / Ant height Factor (dB) Net (dBuV/m) Limit (dBuV/m) Margin (dBuV/m) 0 X 3.078 30.32 19.20 0.07 38.90 10.69 29.50 18.81 0 X 12.95 35.39 19.09 0.15 38.90 15.73 29.50 13.77 10.7 X 3.974 31.06 19.20 0.08 38.90 11.44 29.50 18.06 42.9 X 4.319 36.32 19.20 0.09 38.90 16.71 29.50 12.79 64.4 X 4.218 37.75 19.20 0.09 38.90 18.14 29.50 11.36 85.9 X 1.89 39.20 19.20 0.05 38.90 19.55 29.50 9.95 0 Y 3.078 33.80 19.20 0.07 38.90 14.17 29.50 15.33 0 Y 12.95 35.66 19.09 0.15 38.90 16.00 29.50 13.50 10.7 Y 4.294 36.24 19.20 0.09 38.90 16.63 29.50 12.87 10.7 Y 6.35 34.26 19.20 0.11 38.90 14.67 29.50 14.83 42.9 Y 7.218 39.39 19.20 0.11 38.90 19.80 29.50 9.70 64.4 Y 1.1 36.96 19.20 0.04 38.90 17.30 29.50 12.20 64.4 Y 3.834 30.11 19.20 0.08 38.90 10.49 29.50 19.01 85.9 Y 1.182 32.87 19.20 0.04 38.90 13.21 29.50 16.29 85.9 Y 3.25 29.73 19.20 0.07 38.90 10.10 29.50 19.40 0 H 31.56 22.04 11.28 0.26 -5.00 38.58 40.00 1.42 0 H 41.28 20.07 13.90 0.30 -5.00 39.27 40.00 0.73 10.7 H 44.88 19.40 13.90 0.31 -5.00 38.61 40.00 1.39 10.7 H 146.52 23.20 8.33 0.59 -5.00 37.12 43.50 6.38 32.2 H 232.72 20.60 11.78 0.73 -5.00 38.11 46.00 7.89 32.2 H 393.24 16.16 16.09 0.95 -5.00 38.20 46.00 7.80 42.9 H 37.00 21.13 12.97 0.28 -5.00 39.38 40.00 0.62 42.9 H 382.16 22.28 15.75 0.95 -5.00 43.98 46.00 2.02 64.4 H 176.24 25.75 9.21 0.64 -5.00 40.60 43.50 2.90 64.4 H 188.76 26.94 10.01 0.65 -5.00 42.60 43.50 0.90 85.9 H 436.12 19.75 16.81 1.00 -5.00 42.56 46.00 3.44 0 V 33.32 19.66 11.83 0.26 -5.00 36.75 40.00 3.25 0 V 38.84 20.42 13.54 0.29 -5.00 39.25 40.00 0.75 10.7 V 40.76 20.70 13.90 0.29 -5.00 39.89 40.00 0.11 42.9 V 44.71 16.91 13.90 0.31 -5.00 36.12 40.00 3.88 42.9 V 755.6 17.33 20.97 1.30 -5.00 44.60 46.00 1.40 64.4 V 433.92 19.52 16.77 1.00 -5.00 42.29 46.00 3.71 Note 1: H = D + E + F G; J = I-H Note 2: the QP detector is applied based on that the pulse-repetition frequency of assessed signal is higher than 20 Hz. FCC ID: QISARDCM-1PHT TTRF15g_V1©2015Intertek Test report no. 160900971SHA-003 Page 27 of 32 2MHz-12MHz, Overhead location 2 A B C D E F G H I J Test Point (m) Ant. Pol. Freq. (MHz) Reading (dBuV/m) Ant. Factor (dB) Cable loss (dB) Slant factor / Ant height Factor (dB) Net (dBuV/m) Limit (dBuV/m) Margin (dBuV/m) 0 X 1.522 33.33 19.20 0.05 38.90 13.68 29.50 15.82 10.7 X 2.406 30.88 19.20 0.06 38.90 11.24 29.50 18.26 21.5 X 3.102 34.99 19.20 0.07 38.90 15.36 29.50 14.14 32.2 X 4.21 35.09 19.20 0.09 38.90 15.48 29.50 14.02 42.9 X 4.962 30.77 19.20 0.10 38.90 11.17 29.50 18.33 64.4 X 0.328 40.41 18.90 0.02 38.90 20.43 29.50 9.07 85.9 X 14.654 27.75 19.23 0.17 38.90 8.25 29.50 21.25 0 Y 1.522 33.62 19.20 0.05 38.90 13.97 29.50 15.53 0 Y 3.77 31.41 19.20 0.08 38.90 11.79 29.50 17.71 10.7 Y 4.45 38.51 19.20 0.09 38.90 18.90 29.50 10.60 10.7 Y 20.798 55.12 19.56 0.21 38.90 35.35 29.50 13.28 21.5 Y 1.522 34.96 19.20 0.05 38.90 15.31 29.50 14.19 32.2 Y 3.586 36.04 19.20 0.08 38.90 16.42 29.50 13.08 42.9 Y 1.611 39.32 19.20 0.05 38.90 19.67 29.50 9.83 85.9 Y 1.332 37.25 19.20 0.04 38.90 17.59 29.50 11.91 0 H 31.45 22.38 11.25 0.26 -5.00 38.89 40.00 1.11 0 H 39.68 18.36 13.80 0.29 -5.00 37.45 40.00 2.55 10.7 H 44.21 17.04 13.90 0.31 -5.00 36.25 40.00 3.75 21.5 H 329.96 15.94 14.13 0.92 -5.00 35.99 46.00 10.01 32.2 H 827.72 13.11 21.89 1.34 -5.00 41.34 46.00 4.66 42.9 H 65.92 22.66 10.72 0.38 -5.00 38.76 40.00 1.24 42.9 H 188.29 23.96 9.98 0.65 -5.00 39.59 43.50 3.91 85.9 H 40.27 18.99 13.90 0.29 -5.00 38.18 40.00 1.82 0 V 33.20 19.07 11.79 0.26 -5.00 36.12 40.00 3.88 10.7 V 38.20 20.66 13.34 0.28 -5.00 39.28 40.00 0.72 10.7 V 40.76 18.93 13.90 0.29 -5.00 38.12 40.00 1.88 32.2 V 325.6 15.97 13.99 0.92 -5.00 35.88 46.00 10.12 32.2 V 427.32 16.17 16.68 0.99 -5.00 38.84 46.00 7.16 42.9 V 193.86 24.65 10.37 0.66 -5.00 40.68 43.50 2.82 42.9 V 279.28 23.18 12.83 0.84 -5.00 41.85 46.00 4.15 64.4 V 450.92 18.91 17.01 1.02 -5.00 41.94 46.00 4.06 85.9 V 433.67 17.52 16.77 1.00 -5.00 40.29 46.00 5.71 Note 1: H = D + E + F G; J = I-H Note 2: the QP detector is applied based on that the pulse-repetition frequency of assessed signal is higher than 20 Hz. FCC ID: QISARDCM-1PHT TTRF15g_V1©2015Intertek Test report no. 160900971SHA-003 Page 28 of 32 2MHz-12MHz, Overhead location 3 A B C D E F G H I J Test Point (m) Ant. Pol. Freq. (MHz) Reading (dBuV/m) Ant. Factor (dB) Cable loss (dB) Slant factor / Ant height Factor (dB) Net (dBuV/m) Limit (dBuV/m) Margin (dBuV/m) 0 X 3.582 57.91 19.20 0.08 38.90 38.63 29.50 10.49 0 X 3.726 59.19 19.20 0.08 38.90 39.91 29.50 9.21 10.7 X 4.19 55.52 19.20 0.09 38.90 36.23 29.50 12.88 21.5 X 4.934 54.54 19.20 0.10 38.90 35.24 29.50 13.86 21.5 X 5.702 57.03 19.20 0.10 38.90 37.73 29.50 11.37 42.9 X 6.598 58.52 19.20 0.11 38.90 39.21 29.50 9.88 64.4 X 0.319 44.49 18.90 0.02 38.90 24.51 29.50 4.99 64.4 X 11.5 37.66 18.98 0.14 38.90 17.88 29.50 11.62 85.9 X 2.38 35.74 19.20 0.06 38.90 16.10 29.50 13.40 0 Y 2.394 31.92 19.20 0.06 38.90 12.28 29.50 17.22 42.9 Y 3.726 40.74 19.20 0.08 38.90 21.12 29.50 8.38 42.9 Y 4.198 39.56 19.20 0.09 38.90 19.95 29.50 9.55 64.4 Y 4.93 37.61 19.20 0.10 38.90 18.01 29.50 11.49 85.9 Y 5.702 40.04 19.20 0.10 38.90 20.44 29.50 9.06 85.9 Y 4.942 39.87 19.20 0.10 38.90 20.27 29.50 9.23 0 H 33.72 18.78 11.95 0.26 -5.00 35.99 40.00 4.01 0 H 39.48 16.75 13.74 0.29 -5.00 35.78 40.00 4.22 10.7 H 188.68 20.52 10.01 0.65 -5.00 36.18 43.50 7.32 10.7 H 346.78 18.93 14.65 0.94 -5.00 39.52 46.00 6.48 21.5 H 139.5 26.09 8.33 0.58 -5.00 40.00 43.50 3.50 32.2 H 383.55 22.11 15.79 0.95 -5.00 43.85 46.00 2.15 32.2 H 460.12 16.09 17.14 1.03 -5.00 39.26 46.00 6.74 42.9 H 246.65 25.13 12.20 0.75 -5.00 43.08 46.00 2.92 42.9 H 687.51 15.00 20.20 1.25 -5.00 41.45 46.00 4.55 64.4 H 464.82 18.69 17.21 1.03 -5.00 41.93 46.00 4.07 85.9 H 223.76 22.94 11.51 0.71 -5.00 40.16 46.00 5.84 0 V 37.32 20.66 13.07 0.28 -5.00 39.01 40.00 0.99 21.5 V 42.68 19.04 13.90 0.30 -5.00 38.24 40.00 1.76 21.5 V 227.32 18.08 11.62 0.72 -5.00 35.42 46.00 10.58 32.2 V 161.8 21.20 8.49 0.62 -5.00 35.31 43.50 4.69 64.4 V 281.67 23.11 12.87 0.84 -5.00 41.82 46.00 4.18 85.9 V 418.56 19.46 16.56 0.98 -5.00 42.00 46.00 4.00 Note 1: H = D + E + F G; J = I-H Note 2: the QP detector is applied based on that the pulse-repetition frequency of assessed signal is higher than 20 Hz. FCC ID: QISARDCM-1PHT TTRF15g_V1©2015Intertek Test report no. 160900971SHA-003 Page 29 of 32 Both frequency bands, Underground location 1 A B C D E F G H I J Test Angle (degree) Ant. Pol. Freq. (MHz) Reading (dBuV/m) Ant. Factor (dB) Cable loss (dB) Ant height / Distance Factor (dB) Net Limit Margin (dBuV/m) (dBuV/m) (dBuV/m) 0 X 0.346 45.07 18.90 0.02 40.00 23.99 29.50 5.51 0 X 1.85 40.38 19.20 0.05 40.00 19.63 29.50 9.87 45 X 1.458 36.34 19.20 0.05 40.00 15.59 29.50 13.91 67.5 X 2.854 33.76 19.20 0.07 40.00 13.03 29.50 16.47 67.5 X 3.458 37.09 19.20 0.08 40.00 16.37 29.50 13.13 90 X 0.518 39.12 18.91 0.03 40.00 18.06 29.50 11.44 112.5 X 1.89 34.36 19.20 0.05 40.00 13.61 29.50 15.89 135 X 2.61 37.25 19.20 0.06 40.00 16.51 29.50 12.99 202.5 X 3.786 35.65 19.20 0.08 40.00 14.93 29.50 14.57 0 Y 0.186 42.67 19.07 0.02 40.00 21.76 29.50 7.74 0 Y 6.35 37.83 19.20 0.11 40.00 17.14 29.50 12.36 45 Y 0.698 44.28 18.97 0.03 40.00 23.28 29.50 6.22 45 Y 1.564 36.12 19.20 0.05 40.00 15.37 29.50 14.13 157.5 Y 4.242 35.81 19.20 0.09 40.00 15.10 29.50 14.40 180 Y 0.562 47.85 18.92 0.03 40.00 26.80 29.50 2.70 202.5 Y 2.442 34.46 19.20 0.06 40.00 13.72 29.50 15.78 315 Y 3.054 32.15 19.20 1.11 40.00 12.46 29.50 17.04 337.5 Y 1.866 31.97 19.20 0.05 40.00 11.22 29.50 18.28 337.5 Y 5.47 36.64 19.20 0.10 40.00 15.94 29.50 13.56 0 H 250 21.37 12.30 0.76 -5.00 39.43 46.00 6.57 45 H 332.92 17.68 14.22 0.92 -5.00 37.82 46.00 8.18 67.5 H 440.66 17.70 16.87 1.01 -5.00 40.58 46.00 5.42 90 H 35.28 19.38 12.44 0.27 -5.00 37.09 40.00 2.91 112.5 H 62.52 19.10 11.40 0.37 -5.00 35.87 40.00 4.13 202.5 H 49.65 17.14 13.90 0.33 -5.00 36.37 40.00 3.63 225 H 250 24.65 12.30 0.76 -5.00 42.71 46.00 3.29 247.5 H 342.76 16.36 14.53 0.93 -5.00 36.82 46.00 9.18 337.5 H 451.8 16.26 17.03 1.02 -5.00 39.31 46.00 6.69 0 V 416.8 16.44 16.54 0.97 -5.00 38.95 46.00 7.05 67.5 V 567.16 16.14 18.91 1.11 -5.00 41.16 46.00 4.84 90 V 49.72 19.90 13.90 0.33 -5.00 39.13 40.00 0.87 135 V 500 20.80 17.70 1.07 -5.00 44.57 46.00 1.43 270 V 587 17.91 19.27 1.13 -5.00 43.31 46.00 2.69 Note 1: H = D + E + F G; J = I-H Note 2: the QP detector is applied based on that the pulse-repetition frequency of assessed signal is higher than 20 Hz. FCC ID: QISARDCM-1PHT TTRF15g_V1©2015Intertek Test report no. 160900971SHA-003 Page 30 of 32 Both frequency bands, Underground location 2 A B C D E F G H I J Test Angle (degree) Ant. Pol. Freq. (MHz) Reading (dBuV/m) Ant. Factor (dB) Cable loss (dB) Ant height / Distance Factor (dB) Net Limit Margin (dBuV/m) (dBuV/m) (dBuV/m) 0 X 1.577 39.01 19.20 0.05 40.00 18.26 29.50 11.24 0 X 3.75 36.79 19.20 0.08 40.00 16.07 29.50 13.43 45 X 1.644 39.13 19.20 0.05 40.00 18.38 29.50 11.12 45 X 4.111 34.49 19.20 0.09 40.00 13.78 29.50 15.72 67.5 X 7.247 37.43 19.20 0.11 40.00 16.74 29.50 12.76 90 X 0.818 41.46 19.02 0.04 40.00 20.52 29.50 8.98 112.5 X 4.503 33.99 19.20 0.09 40.00 13.28 29.50 16.22 135 X 21.06 36.95 19.61 0.21 40.00 16.77 29.50 12.73 247.5 X 1.198 47.37 19.20 0.04 40.00 26.61 29.50 2.89 337.5 X 6.518 37.38 19.20 0.11 40.00 16.69 29.50 12.81 0 Y 0.554 44.63 18.92 0.03 40.00 23.58 29.50 5.92 0 Y 1.822 34.10 19.20 0.05 40.00 13.35 29.50 16.15 157.5 Y 5.911 36.60 19.20 0.11 40.00 15.91 29.50 13.59 157.5 Y 1.449 40.56 19.20 0.05 40.00 19.81 29.50 9.69 180 Y 15.75 34.53 19.13 0.18 40.00 13.84 29.50 15.66 202.5 Y 5.894 36.93 19.20 0.11 40.00 16.24 29.50 13.26 315 Y 8.218 33.40 19.20 1.12 40.00 13.72 29.50 15.78 337.5 Y 0.802 40.80 19.00 0.04 40.00 19.84 29.50 9.66 22.5 H 62.78 20.28 11.34 0.37 -5.00 36.99 40.00 3.01 90 H 250.01 20.10 12.30 0.76 -5.00 38.16 46.00 7.84 112.5 H 289.12 20.59 13.00 0.86 -5.00 39.45 46.00 6.55 135 H 189.29 20.85 10.05 0.66 -5.00 36.56 43.50 6.94 225 H 207.2 20.28 11.02 0.68 -5.00 36.98 43.50 6.52 247.5 H 250.33 19.36 12.31 0.76 -5.00 37.43 46.00 8.57 247.5 H 38.08 21.19 13.30 0.28 -5.00 39.77 40.00 0.23 337.5 H 250 22.62 12.30 0.76 -5.00 40.68 46.00 5.32 0 V 53.3 20.55 13.24 0.34 -5.00 39.13 40.00 0.87 22.5 V 76.42 23.96 8.49 0.41 -5.00 37.86 40.00 2.14 45 V 350.26 18.12 14.76 0.94 -5.00 38.82 46.00 7.18 67.5 V 460.09 15.88 17.14 1.03 -5.00 39.05 46.00 6.95 90 V 465.76 15.03 17.22 1.04 -5.00 38.29 46.00 7.71 135 V 53.45 20.61 13.21 0.34 -5.00 39.16 40.00 0.84 202.5 V 254.07 19.44 12.37 0.77 -5.00 37.58 46.00 8.42 270 V 45.6 17.72 13.90 0.31 -5.00 36.93 40.00 3.07 315 V 250 22.83 12.30 0.76 -5.00 40.89 46.00 5.11 Note 1: H = D + E + F G; J = I-H Note 2: the QP detector is applied based on that the pulse-repetition frequency of assessed signal is higher than 20 Hz. FCC ID: QISARDCM-1PHT TTRF15g_V1©2015Intertek Test report no. 160900971SHA-003 Page 31 of 32 Both frequency bands, Underground location 3 A B C D E F G H I J Test Angle (degree) Ant. Pol. Freq. (MHz) Reading (dBuV/m) Ant. Factor (dB) Cable loss (dB) Ant height / Distance Factor (dB) Net Limit Margin (dBuV/m) (dBuV/m) (dBuV/m) 0 X 3.686 39.88 19.20 0.08 40.00 19.16 29.50 10.34 0 X 3.778 38.86 19.20 0.08 40.00 18.14 29.50 11.36 45 X 1.594 41.88 19.20 0.05 40.00 21.13 29.50 8.37 45 X 8.486 34.49 19.20 0.12 40.00 13.81 29.50 15.69 67.5 X 1.042 35.95 19.20 0.04 40.00 15.19 29.50 14.31 90 X 4.45 34.14 19.20 0.09 40.00 13.43 29.50 16.07 112.5 X 0.959 42.34 19.16 0.04 40.00 21.54 29.50 7.96 315 X 4.248 36.57 19.20 0.09 40.00 15.86 29.50 13.64 337.5 X 11.69 39.20 18.95 0.14 40.00 18.29 29.50 11.21 0 Y 2.514 32.12 19.20 0.06 40.00 11.38 29.50 18.12 22.5 Y 3.39 37.26 19.20 0.08 40.00 16.54 29.50 12.96 22.5 Y 3.81 39.17 19.20 0.08 40.00 18.45 29.50 11.05 90 Y 5.77 34.49 19.20 0.10 40.00 13.79 29.50 15.71 157.5 Y 2.498 30.96 19.20 0.06 40.00 10.22 29.50 19.28 180 Y 1.557 38.12 19.20 0.05 40.00 17.37 29.50 12.13 202.5 Y 5.719 31.76 19.20 0.10 40.00 11.06 29.50 18.44 315 Y 8.714 36.37 19.20 1.12 40.00 16.69 29.50 12.81 337.5 Y 12.246 30.13 18.95 0.15 40.00 9.23 29.50 20.27 45 H 43.56 18.52 13.90 0.30 -5.00 37.72 40.00 2.28 90 H 50.72 18.92 13.76 0.33 -5.00 38.01 40.00 1.99 112.5 H 159.76 25.44 8.40 0.61 -5.00 39.45 43.50 4.05 135 H 340.2 15.93 14.45 0.93 -5.00 36.31 46.00 9.69 225 H 446.24 18.47 16.95 1.01 -5.00 41.43 46.00 4.57 180 H 77.36 25.40 8.28 0.42 -5.00 39.10 40.00 0.90 225 H 374.96 20.46 15.52 0.94 -5.00 41.92 46.00 4.08 337.5 H 353.2 16.53 14.85 0.94 -5.00 37.32 46.00 8.68 0 V 126.32 25.09 9.12 0.55 -5.00 39.76 43.50 3.74 0 V 172.72 22.96 9.04 0.63 -5.00 37.63 43.50 5.87 45 V 227.4 22.46 11.62 0.72 -5.00 39.80 46.00 6.20 67.5 V 428.4 16.84 16.70 0.99 -5.00 39.53 46.00 6.47 90 V 460.52 19.91 17.15 1.03 -5.00 43.09 46.00 2.91 135 V 74.12 22.93 8.99 0.41 -5.00 37.33 40.00 2.67 157.5 V 250 19.86 12.30 0.76 -5.00 37.92 46.00 8.08 315 V 264.45 19.79 12.56 0.80 -5.00 38.15 46.00 7.85 315 V 404.55 15.57 16.36 0.96 -5.00 37.89 46.00 8.11 Note 1: H = D + E + F G; J = I-H Note 2: the QP detector is applied based on that the pulse-repetition frequency of assessed signal is higher than 20 Hz. FCC ID: QISARDCM-1PHT TTRF15g_V1©2015Intertek Representative emissions spectrum Plot Test report no. 160900971SHA-003 Page 32 of 32 FCC ID: QISARDCM-1PHT TTRF15g_V1©2015Intertek
Related FCC IDs:
- QISARDCM-1PHT - Huawei Technologies Co.,Ltd ARDCM-1PHT [ARDCM-1PHT] GPL Ghostscript 9.0