Hank Yan

Test report

Dongguan Wangpeng Hardware Products Co., Ltd. A18 Portable Wireless Charger For Apple Watch 2BOJS-A18 2BOJSA18 a18

PDF Viewing Options

Not Your Device? Search For Manuals or Datasheets below:


File Info : application/pdf, 25 Pages, 1.88MB

Document DEVICE REPORTGetApplicationAttachment.html?id=8197053
Test Report

Report No. Date of issue
Applicant Product Model(s) FCC ID

: MTi250321005-0102E1 : 2025-04-02 : Dongguan Wangpeng Hardware Products Co., Ltd : Portable Wireless Charger For Apple Watch : A18 : 2BOJS-A18

Shenzhen Microtest Co., Ltd.

Tel:0755-88850135-1439 Mobile: 131-4343-1439Wechat same number Web: http://www.mtitest.cn

E-mail: [email protected]

Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao'an District, Shenzhen, Guangdong,China

Q/MTI-QP-12-FE038

Ver./Rev.A1

Page 1 of 25

TEST REPORT

Report No.: MTi250321005-0102E1

Table of contents

1 General Description ..................................................................................................................... 4 1.1 Description of the EUT ........................................................................................................ 4 1.2 Description of test modes.................................................................................................... 4 1.3 Environmental Conditions ................................................................................................... 5 1.4 Description of support units ................................................................................................ 5 1.5 Measurement uncertainty.................................................................................................... 5
2 Summary of Test Result .............................................................................................................. 6 3 Test Facilities and accreditations ............................................................................................... 7
3.1 Test laboratory..................................................................................................................... 7
4 List of test equipment .................................................................................................................. 8 5 Evaluation Results (Evaluation) ................................................................................................. 9
5.1 Antenna requirement........................................................................................................... 9
6 Radio Spectrum Matter Test Results (RF) ............................................................................... 10 6.1 Conducted Emission at AC power line.............................................................................. 10 6.2 20dB Occupied Bandwidth................................................................................................ 13 6.3 Emissions in frequency bands (below 30MHz)................................................................. 16 6.4 Emissions in frequency bands (30MHz - 1GHz)............................................................... 19
Photographs of the test setup ......................................................................................................... 23 Photographs of the EUT ................................................................................................................... 24

Tel: 0755-88850135-1439 Mobile: 131-4343-1439 (Wechat same number)

Web: http://www.mtitest.cn

E-mail: [email protected]

Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao'an District, Shenzhen, Guangdong,China

Q/MTI-QP-12-FE038

Ver./Rev.A1

Page 2 of 25

TEST REPORT

Report No.: MTi250321005-0102E1

Test Result Certification

Applicant

Dongguan Wangpeng Hardware Products Co., Ltd

Applicant Address

102, 1st Floor, Building A3, Qihua Industrial Zone, Fenggang Town, Dongguan City

Manufacturer Dongguan Wangpeng Hardware Products Co., Ltd

Manufacturer Address

102, 1st Floor, Building A3, Qihua Industrial Zone, Fenggang Town, Dongguan City

Product description

Product name Portable Wireless Charger For Apple Watch

Trademark

ZIKUREL, iWpeng

Model name A18

Series Model(s) N/A

Standards

47 CFR Part 15C

Test Method ANSI C63.10-2013

Testing Information

Date of test

2025-03-24 to 2025-03-26

Test result

Pass

Prepared by:

James Qin

Reviewed by:

David Lee

Approved by:

Lewis Lian

Tel: 0755-88850135-1439 Mobile: 131-4343-1439 (Wechat same number)

Web: http://www.mtitest.cn

E-mail: [email protected]

Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao'an District, Shenzhen, Guangdong,China

Q/MTI-QP-12-FE038

Ver./Rev.A1

Page 3 of 25

TEST REPORT
1 General Description

Report No.: MTi250321005-0102E1

1.1 Description of the EUT

Product name:

Portable Wireless Charger For Apple Watch

Model name:

A18

Series Model(s):

N/A

Model difference: Electrical rating:
Accessories: Hardware version:

N/A
Input: DC 5V/ 2A Output: 3W Capacity: 2000mAh(3.7V/ 7.4Wh) Cable: Type-c to Type-c cable: 100cm
A08-D

Software version:

0D58

Test sample(s) number: MTi250321005-01-R001

RF specification
Operating frequency range: Modulation type:

300-360kHz ASK

1.2 Description of test modes No.

Emission test modes

Mode1

Wireless output Watch(3W)

Mode2

stand by

Tel: 0755-88850135-1439 Mobile: 131-4343-1439 (Wechat same number)

Web: http://www.mtitest.cn

E-mail: [email protected]

Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao'an District, Shenzhen, Guangdong,China

Q/MTI-QP-12-FE038

Ver./Rev.A1

Page 4 of 25

TEST REPORT

Report No.: MTi250321005-0102E1

1.3 Environmental Conditions

During the measurement the environmental conditions were within the listed ranges:

Temperature: Humidity: Atmospheric pressure:

15°C ~ 35°C 20% RH ~ 75% RH 98 kPa ~ 101 kPa

1.4 Description of support units Support equipment list

Description
HUAWEI QUICK CHARGE
Watch

Model HW-200200ZP1
iWatch SE

Serial No. JN67LSN7N03451 FH7PP6BAG91J6

Manufacturer HUAWEI Apple

Support cable list

Description

Length (m)

From

To

/

/

/

/

1.5 Measurement uncertainty

Measurement

Uncertainty

Conducted emissions (AMN 150kHz~30MHz) Occupied channel bandwidth Radiated spurious emissions (9kHz~30MHz) Radiated spurious emissions (30MHz~1GHz) Temperature Humidity

±3.1dB ±3 % ±4.3dB ±4.7dB ±1 °C ± 5 %

This uncertainty represents an expanded uncertainty expressed at approximately the 95% confidence level using a coverage factor of k=2.

Tel: 0755-88850135-1439 Mobile: 131-4343-1439 (Wechat same number)

Web: http://www.mtitest.cn

E-mail: [email protected]

Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao'an District, Shenzhen, Guangdong,China

Q/MTI-QP-12-FE038

Ver./Rev.A1

Page 5 of 25

TEST REPORT
2 Summary of Test Result

Report No.: MTi250321005-0102E1

No. Item

1 Antenna requirement

2

Conducted Emission at AC power line

Standard 47 CFR Part 15C
47 CFR Part 15C

3 20dB Occupied Bandwidth 47 CFR Part 15C

4

Emissions in frequency bands (below 30MHz)

5

Emissions in frequency bands (30MHz - 1GHz)

47 CFR Part 15C 47 CFR Part 15C

Requirement
47 CFR Part 15.203 47 CFR Part 15.207(a) 47 CFR Part 15.215(c)
47 CFR Part 15.209

Result Pass Pass
Pass
Pass

47 CFR Part 15.209 Pass

Tel: 0755-88850135-1439 Mobile: 131-4343-1439 (Wechat same number)

Web: http://www.mtitest.cn

E-mail: [email protected]

Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao'an District, Shenzhen, Guangdong,China

Q/MTI-QP-12-FE038

Ver./Rev.A1

Page 6 of 25

TEST REPORT
3 Test Facilities and accreditations

Report No.: MTi250321005-0102E1

3.1 Test laboratory

Test laboratory: Test site location: Telephone:

Shenzhen Microtest Co., Ltd.
101, No.7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China
(86-755)88850135

Fax:

(86-755)88850136

CNAS Registration No.: CNAS L5868

FCC Registration No.: 448573

IC Registration No.:

21760

CABID:

CN0093

Tel: 0755-88850135-1439 Mobile: 131-4343-1439 (Wechat same number)

Web: http://www.mtitest.cn

E-mail: [email protected]

Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao'an District, Shenzhen, Guangdong,China

Q/MTI-QP-12-FE038

Ver./Rev.A1

Page 7 of 25

TEST REPORT
4 List of test equipment

Report No.: MTi250321005-0102E1

No.

Equipment

Manufacturer

Model

Serial No. Cal. date Cal. Due

Conducted Emission at AC power line

1

EMI Test Receiver

Rohde&schwarz

ESCI3

101368

2025-03- 2026-03-

13

12

2 Artificial mains network Schwarzbeck NSLK 8127

183

2025-03- 2026-03-

18

17

3 Artificial Mains Network

Rohde & Schwarz

ESH2-Z5

100263

2025-03- 2026-03-

18

17

20dB Occupied Bandwidth

1

Wideband Radio Communication Tester

Rohde&schwarz

2

ESG Series Analog Ssignal Generator

Agilent

3

PXA Signal Analyzer

Agilent

4 Synthesized Sweeper

Agilent

5 MXA Signal Analyzer

Agilent

6

RF Control Unit

Tonscend

7 Band Reject Filter Group

8

ESG Vector Signal Generator

9

DC Power Supply

Tonscend Agilent Agilent

CMW500 E4421B N9030A 83752A N9020A JS0806-1 JS0806-F N5182A E3632A

149155
GB400512 40
MY513502 96
3610A019 57
MY501434 83
19D80601 52
19D80601 60
MY501437 62
MY400276 95

2025-0318
2025-0314
2025-0314
2025-0318
2025-0318
2025-0318
2025-0318
2025-0314
2025-0318

2026-0317
2026-0313
2026-0313
2026-0317
2026-0317
2026-0317
2026-0317
2026-0313
2026-0317

Emissions in frequency bands (below 30MHz)

1

EMI Test Receiver

Rohde&schwarz

ESCI7

101166

2025-03- 2026-03-

14

13

2

Active Loop Antenna

Schwarzbeck FMZB 1519 B 00066

2024-03- 2026-03-

23

22

3

Amplifier

Hewlett-Packard

8447F

3113A0618 2025-03- 2026-03-

4

18

17

Emissions in frequency bands (30MHz - 1GHz)

1

EMI Test Receiver

Rohde&schwarz

ESCI7

101166

2025-03- 2026-03-

14

13

2

TRILOG Broadband Antenna

schwarabeck

VULB 9163

9163-1338 2023-06-11

2025-0610

3

Active Loop Antenna

Schwarzbeck FMZB 1519 B 00066

2024-03- 2026-03-

23

22

4

Amplifier

Hewlett-Packard

8447F

3113A0618 2025-03- 2026-03-

4

18

17

Tel: 0755-88850135-1439 Mobile: 131-4343-1439 (Wechat same number)

Web: http://www.mtitest.cn

E-mail: [email protected]

Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao'an District, Shenzhen, Guangdong,China

Q/MTI-QP-12-FE038

Ver./Rev.A1

Page 8 of 25

TEST REPORT
5 Evaluation Results (Evaluation)

Report No.: MTi250321005-0102E1

5.1 Antenna requirement

Test Requirement:

Refer to 47 CFR Part 15.203, an intentional radiator shall be designed to ensure that no antenna other than that furnished by the responsible party shall be used with the device. The use of a permanently attached antenna or of an antenna that uses a unique coupling to the intentional radiator shall be considered sufficient to comply with the provisions of this section.

5.1.1 Conclusion:
The antenna of the EUT is permanently attached. The EUT complies with the requirement of FCC PART 15.203.

Tel: 0755-88850135-1439 Mobile: 131-4343-1439 (Wechat same number)

Web: http://www.mtitest.cn

E-mail: [email protected]

Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao'an District, Shenzhen, Guangdong,China

Q/MTI-QP-12-FE038

Ver./Rev.A1

Page 9 of 25

TEST REPORT
Report No.: MTi250321005-0102E1
6 Radio Spectrum Matter Test Results (RF)

6.1 Conducted Emission at AC power line

Test Requirement: Test Limit:
Test Method: Procedure:

Except as shown in paragraphs (b)and (c)of this section, for an intentional radiator that is designed to be connected to the public utility (AC) power line, the radio frequency voltage that is conducted back onto the AC power line on any frequency or frequencies, within the band 150 kHz to 30 MHz, shall not exceed the limits in the following table, as measured using a 50 H/50 ohms line impedance stabilization network (LISN).

Frequency of emission (MHz)
0.15-0.5 0.5-5 5-30

Conducted limit (dBV)

Quasi-peak

Average

66 to 56*

56 to 46*

56

46

60

50

*Decreases with the logarithm of the frequency.

ANSI C63.10-2013 section 6.2

Refer to ANSI C63.10-2013 section 6.2, standard test method for ac power-line conducted emissions from unlicensed wireless devices

6.1.1 E.U.T. Operation:

Operating Environment:

Temperature: 23.8 °C Humidity: 62 %

Atmospheric Pressure: 100 kPa

Pre test mode:

Mode1, Mode2

Final test mode:

All of the listed pre-test mode were tested, only the data of the worst mode (Mode1) is recorded in the report

6.1.2 Test Setup Diagram:

Tel: 0755-88850135-1439 Mobile: 131-4343-1439 (Wechat same number)

Web: http://www.mtitest.cn

E-mail: [email protected]

Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao'an District, Shenzhen, Guangdong,China

Q/MTI-QP-12-FE038

Ver./Rev.A1

Page 10 of 25

6.1.3 Test Data: Mode1 / Line: Line

TEST REPORT

Report No.: MTi250321005-0102E1

Tel: 0755-88850135-1439 Mobile: 131-4343-1439 (Wechat same number)

Web: http://www.mtitest.cn

E-mail: [email protected]

Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao'an District, Shenzhen, Guangdong,China

Q/MTI-QP-12-FE038

Ver./Rev.A1

Page 11 of 25

Mode1 / Line: Neutral

TEST REPORT

Report No.: MTi250321005-0102E1

Tel: 0755-88850135-1439 Mobile: 131-4343-1439 (Wechat same number)

Web: http://www.mtitest.cn

E-mail: [email protected]

Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao'an District, Shenzhen, Guangdong,China

Q/MTI-QP-12-FE038

Ver./Rev.A1

Page 12 of 25

TEST REPORT
6.2 20dB Occupied Bandwidth

Report No.: MTi250321005-0102E1

Test Requirement: Test Limit:

47 CFR Part 15.215(c)
Refer to 47 CFR 15.215(c), intentional radiators operating under the alternative provisions to the general emission limits, as contained in §§ 15.217 through 15.257 and in subpart E of this part, must be designed to ensure that the 20 dB bandwidth of the emission, or whatever bandwidth may otherwise be specified in the specific rule section under which the equipment operates, is contained within the frequency band designated in the rule section under which the equipment is operated.

Test Method: Procedure:

ANSI C63.10-2013, section 6.9.2
a) The spectrum analyzer center frequency is set to the nominal EUT channel center frequency. The span range for the EMI receiver or spectrum analyzer shall be between two times and five times the OBW. b) The nominal IF filter bandwidth (3 dB RBW) shall be in the range of 1% to 5% of the OBW and video bandwidth (VBW) shall be approximately three times RBW, unless otherwise specified by the applicable requirement. c) Set the reference level of the instrument as required, keeping the signal from exceeding the maximum input mixer level for linear operation. In general, the peak of the spectral envelope shall be more than [10 log (OBW/RBW)] below the reference level. Specific guidance is given in 4.1.5.2. d) Steps a) through c) might require iteration to adjust within the specified tolerances. e) The dynamic range of the instrument at the selected RBW shall be more than 10 dB below the target "-xx dB down" requirement; that is, if the requirement calls for measuring the -20 dB OBW, the instrument noise floor at the selected RBW shall be at least 30 dB below the reference value. f) Set detection mode to peak and trace mode to max hold. g) Determine the reference value: Set the EUT to transmit an unmodulated carrier or modulated signal, as applicable. Allow the trace to stabilize. Set the spectrum analyzer marker to the highest level of the displayed trace (this is the reference value). h) Determine the "-xx dB down amplitude" using [(reference value) - xx]. Alternatively, this calculation may be made by using the markerdelta function of the instrument. i) If the reference value is determined by an unmodulated carrier, then turn the EUT modulation ON, and either clear the existing trace or start a new trace on the spectrum analyzer and allow the new trace to stabilize. Otherwise, the trace from step g) shall be used for step j). j) Place two markers, one at the lowest frequency and the other at the highest frequency of the envelope of the spectral display, such that each marker is at or slightly below the "-xx dB down amplitude" determined in step h). If a marker is below this "-xx dB down amplitude" value, then it shall be as close as possible to this value. The occupied bandwidth is the frequency difference between the two markers. Alternatively, set a marker at the lowest frequency of the envelope of the spectral display, such that the marker is at or slightly below the "-xx dB down amplitude" determined in step h). Reset the

Tel: 0755-88850135-1439 Mobile: 131-4343-1439 (Wechat same number)

Web: http://www.mtitest.cn

E-mail: [email protected]

Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao'an District, Shenzhen, Guangdong,China

Q/MTI-QP-12-FE038

Ver./Rev.A1

Page 13 of 25

TEST REPORT
Report No.: MTi250321005-0102E1
marker-delta function and move the marker to the other side of the emission until the delta marker amplitude is at the same level as the reference marker amplitude. The marker-delta frequency reading at this point is the specified emission bandwidth. k) The occupied bandwidth shall be reported by providing plot(s) of the measuring instrument display; the plot axes and the scale units per division shall be clearly labeled. Tabular data may be reported in addition to the plot(s).

6.2.1 E.U.T. Operation:

Operating Environment:

Temperature: 25.3 °C Humidity: 56 %

Atmospheric Pressure: 101 kPa

Pre test mode: Final test mode:

Mode1, Mode2 All of the listed pre-test mode were tested, only the data of the worst mode (Mode1) is recorded in the report

6.2.2 Test Setup Diagram:

Tel: 0755-88850135-1439 Mobile: 131-4343-1439 (Wechat same number)

Web: http://www.mtitest.cn

E-mail: [email protected]

Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao'an District, Shenzhen, Guangdong,China

Q/MTI-QP-12-FE038

Ver./Rev.A1

Page 14 of 25

6.2.3 Test Data:

TEST REPORT

Report No.: MTi250321005-0102E1

Note: Because the measured signal is CW-like, adjusting the RBW per C63.10 would not be practical since measurement bandwidth will always follow the RBW. The RBW is set to 300 Hz to perform the occupied bandwidth test.

Frequency kHz
329.05

20 dB occupied bandwidth Hz 966

99% occupied bandwidth Hz 881

Tel: 0755-88850135-1439 Mobile: 131-4343-1439 (Wechat same number)

Web: http://www.mtitest.cn

E-mail: [email protected]

Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao'an District, Shenzhen, Guangdong,China

Q/MTI-QP-12-FE038

Ver./Rev.A1

Page 15 of 25

TEST REPORT
6.3 Emissions in frequency bands (below 30MHz)

Report No.: MTi250321005-0102E1

Test Requirement: Test Limit:
Test Method: Procedure:

47 CFR Part 15.209 Frequency (MHz)
0.009-0.490 0.490-1.705 1.705-30.0 30-88 88-216 216-960 Above 960

Field strength (microvolts/meter)
2400/F(kHz) 24000/F(kHz) 30 100 ** 150 ** 200 ** 500

Measuremen t distance (meters) 300 30 30 3 3 3 3

** Except as provided in paragraph (g), fundamental emissions from intentional radiators operating under this section shall not be located in the frequency bands 54-72 MHz, 76-88 MHz, 174-216 MHz or 470806 MHz. However, operation within these frequency bands is permitted under other sections of this part, e.g., §§ 15.231 and 15.241. In the emission table above, the tighter limit applies at the band edges. The emission limits shown in the above table are based on measurements employing a CISPR quasi-peak detector except for the frequency bands 9­90 kHz, 110­490 kHz and above 1000 MHz. Radiated emission limits in these three bands are based on measurements employing an average detector. As shown in § 15.35(b), for frequencies above 1000 MHz, the field strength limits in paragraphs (a)and (b)of this section are based on average limits. However, the peak field strength of any emission shall not exceed the maximum permitted average limits specified above by more than 20 dB under any condition of modulation. For point-to-point operation under paragraph (b)of this section, the peak field strength shall not exceed 2500 millivolts/meter at 3 meters along the antenna azimuth.

ANSI C63.10-2013 section 6.4

ANSI C63.10-2013 section 6.4

6.3.1 E.U.T. Operation:

Operating Environment:

Temperature: 22.5 °C Humidity: 58 %

Atmospheric Pressure: 101 kPa

Pre test mode: Final test mode:

Mode1, Mode2 All of the listed pre-test mode were tested, only the data of the worst mode (Mode1) is recorded in the report

6.3.2 Test Setup Diagram:

Tel: 0755-88850135-1439 Mobile: 131-4343-1439 (Wechat same number)

Web: http://www.mtitest.cn

E-mail: [email protected]

Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao'an District, Shenzhen, Guangdong,China

Q/MTI-QP-12-FE038

Ver./Rev.A1

Page 16 of 25

TEST REPORT
6.3.3 Test Data: Mode1 / EUT direction: X axis

Report No.: MTi250321005-0102E1

Tel: 0755-88850135-1439 Mobile: 131-4343-1439 (Wechat same number)

Web: http://www.mtitest.cn

E-mail: [email protected]

Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao'an District, Shenzhen, Guangdong,China

Q/MTI-QP-12-FE038

Ver./Rev.A1

Page 17 of 25

TEST REPORT
Mode1 / EUT direction: X axis

Report No.: MTi250321005-0102E1

Tel: 0755-88850135-1439 Mobile: 131-4343-1439 (Wechat same number)

Web: http://www.mtitest.cn

E-mail: [email protected]

Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao'an District, Shenzhen, Guangdong,China

Q/MTI-QP-12-FE038

Ver./Rev.A1

Page 18 of 25

TEST REPORT
6.4 Emissions in frequency bands (30MHz - 1GHz)

Report No.: MTi250321005-0102E1

Test Requirement: Test Limit:
Test Method: Procedure:

47 CFR Part 15.209 Frequency (MHz)
0.009-0.490 0.490-1.705 1.705-30.0 30-88 88-216 216-960 Above 960

Field strength (microvolts/meter)
2400/F(kHz) 24000/F(kHz) 30 100 ** 150 ** 200 ** 500

Measuremen t distance (meters) 300 30 30 3 3 3 3

** Except as provided in paragraph (g), fundamental emissions from intentional radiators operating under this section shall not be located in the frequency bands 54-72 MHz, 76-88 MHz, 174-216 MHz or 470806 MHz. However, operation within these frequency bands is permitted under other sections of this part, e.g., §§ 15.231 and 15.241. In the emission table above, the tighter limit applies at the band edges. The emission limits shown in the above table are based on measurements employing a CISPR quasi-peak detector except for the frequency bands 9­90 kHz, 110­490 kHz and above 1000 MHz. Radiated emission limits in these three bands are based on measurements employing an average detector. As shown in § 15.35(b), for frequencies above 1000 MHz, the field strength limits in paragraphs (a)and (b)of this section are based on average limits. However, the peak field strength of any emission shall not exceed the maximum permitted average limits specified above by more than 20 dB under any condition of modulation. For point-to-point operation under paragraph (b)of this section, the peak field strength shall not exceed 2500 millivolts/meter at 3 meters along the antenna azimuth.

ANSI C63.10-2013 section 6.5

ANSI C63.10-2013 section 6.5

6.4.1 E.U.T. Operation:

Operating Environment:

Temperature: 22.5 °C Humidity: 58 %

Atmospheric Pressure: 101 kPa

Pre test mode:

Mode1, Mode2

Final test mode:

All of the listed pre-test mode were tested, only the data of the worst mode (Mode1) is recorded in the report

Tel: 0755-88850135-1439 Mobile: 131-4343-1439 (Wechat same number)

Web: http://www.mtitest.cn

E-mail: [email protected]

Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao'an District, Shenzhen, Guangdong,China

Q/MTI-QP-12-FE038

Ver./Rev.A1

Page 19 of 25

6.4.2 Test Setup Diagram:

TEST REPORT

Report No.: MTi250321005-0102E1

Tel: 0755-88850135-1439 Mobile: 131-4343-1439 (Wechat same number)

Web: http://www.mtitest.cn

E-mail: [email protected]

Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao'an District, Shenzhen, Guangdong,China

Q/MTI-QP-12-FE038

Ver./Rev.A1

Page 20 of 25

TEST REPORT
6.4.3 Test Data: Mode1 / Polarization: Horizontal

Report No.: MTi250321005-0102E1

Tel: 0755-88850135-1439 Mobile: 131-4343-1439 (Wechat same number)

Web: http://www.mtitest.cn

E-mail: [email protected]

Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao'an District, Shenzhen, Guangdong,China

Q/MTI-QP-12-FE038

Ver./Rev.A1

Page 21 of 25

Mode1 / Polarization: Vertical

TEST REPORT

Report No.: MTi250321005-0102E1

Tel: 0755-88850135-1439 Mobile: 131-4343-1439 (Wechat same number)

Web: http://www.mtitest.cn

E-mail: [email protected]

Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao'an District, Shenzhen, Guangdong,China

Q/MTI-QP-12-FE038

Ver./Rev.A1

Page 22 of 25

TEST REPORT
Photographs of the test setup
Refer to Appendix - Test Setup Photos

Report No.: MTi250321005-0102E1

Tel: 0755-88850135-1439 Mobile: 131-4343-1439 (Wechat same number)

Web: http://www.mtitest.cn

E-mail: [email protected]

Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao'an District, Shenzhen, Guangdong,China

Q/MTI-QP-12-FE038

Ver./Rev.A1

Page 23 of 25

TEST REPORT
Photographs of the EUT
Refer to Appendix - EUT Photos

Report No.: MTi250321005-0102E1

Tel: 0755-88850135-1439 Mobile: 131-4343-1439 (Wechat same number)

Web: http://www.mtitest.cn

E-mail: [email protected]

Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao'an District, Shenzhen, Guangdong,China

Q/MTI-QP-12-FE038

Ver./Rev.A1

Page 24 of 25

TEST REPORT

Report No.: MTi250321005-0102E1

Statement
1. This report is invalid without the seal and signature of the laboratory.
2. The test results of this report are only responsible for the samples submitted.Client shall be responsible for representativeness of the sample and authenticity of the material.
3. The report shall not be partially reproduced without the written consent of the Laboratory.
4. This report is invalid if transferred, altered or tampered with in any form without authorization.
5. The observations or tests with special mark fall outside the scope of accreditation, and are only used for purpose of commission, research, training, internal quality control etc.
6. Any objection to this report shall be submitted to the laboratory within 15 days from the date of receipt of the report.
****** END OF REPORT ******

Tel: 0755-88850135-1439 Mobile: 131-4343-1439 (Wechat same number)

Web: http://www.mtitest.cn

E-mail: [email protected]

Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao'an District, Shenzhen, Guangdong,China

Q/MTI-QP-12-FE038

Ver./Rev.A1

Page 25 of 25



Related FCC IDs:

Search Any Device: