2080-SG001A-EN-P Micro800 Programmable Controllers Selection Guide
Bulletin 2080
Bulletin, 2080
Rockwell Automation
Elit.ee View guide user manual
Download link
2085-IF8 Analog Input Module Micro850, 8-ch., drawn 110mA 5VDC, TS35^panel mount, Allen-Bradley Elit GlobalStore™ - elektritarvikud, automaatika, kontrollerid, IT komponendid
Not Your Device? Search For Manuals or Datasheets below:
File Info : application/pdf, 64 Pages, 656.33KB
Document DEVICE REPORTALBR2085ECR SpecMicro800 Programmable Controller Family Bulletin 2080 Selection Guide Important User Information Solid state equipment has operational characteristics differing from those of electromechanical equipment. Safety Guidelines for the Application, Installation and Maintenance of Solid State Controls (publication SGI-1.1 available from your local Rockwell Automation sales office or online at http://rockwellautomation.com/literature) describes some important differences between solid state equipment and hard-wired electromechanical devices. Because of this difference, and also because of the wide variety of uses for solid state equipment, all persons responsible for applying this equipment must satisfy themselves that each intended application of this equipment is acceptable. In no event will Rockwell Automation, Inc. be responsible or liable for indirect or consequential damages resulting from the use or application of this equipment. The examples and diagrams in this manual are included solely for illustrative purposes. Because of the many variables and requirements associated with any particular installation, Rockwell Automation, Inc. cannot assume responsibility or liability for actual use based on the examples and diagrams. No patent liability is assumed by Rockwell Automation, Inc. with respect to use of information, circuits, equipment, or software described in this manual. Reproduction of the contents of this manual, in whole or in part, without written permission of Rockwell Automation, Inc., is prohibited. Throughout this manual, when necessary, we use notes to make you aware of safety considerations. WARNING Identifies information about practices or circumstances that can cause an explosion in a hazardous environment, which may lead to personal injury or death, property damage, or economic loss. IMPORTANT Identifies information that is critical for successful application and understanding of the product. ATTENTION Identifies information about practices or circumstances that can lead to: personal injury or death, property damage, or economic loss. Attentions help you identify a hazard, avoid a hazard, and recognize the consequence. SHOCK HAZARD Labels may be on or inside the equipment, such as a drive or motor, to alert people that dangerous voltage may be present. BURN HAZARD Labels may be on or inside the equipment, such as a drive or motor, to alert people that surfaces may reach dangerous temperatures. Allen-Bradley, Rockwell Automation, Micro800, Micro810, Micro820, Micro830, Micro850, Connected Components Workbench, FactoryTalk, PowerFlex, CompactBlock, and TechConnect are trademarks of Rockwell Automation, Inc. Trademarks not belonging to Rockwell Automation are property of their respective companies. Select a Micro800 Controller Micro800TM controllers are designed for low-cost, standalone machines. These economical small-size PLCs are available in different form factors based on the number of I/O points embedded in the base, with a range of features intended to address different requirements. The Micro800 family shares programming environment, accessories and plug-ins that allow machine builders to personalize the controller for specific capabilities. Micro810TM controllers function as a smart relay with high current relay outputs, but with the programming capabilities of a micro PLC. The Micro810 controllers come in a 12-point form factor. Micro820TM controllers are specifically designed for smaller standalone machines and remote automation projects. It has embedded Ethernet and serial ports and a microSDTM slot for datalogging and recipe management. These controllers come as 20-point form factors that can accommodate up to two plug-in modules. It also supports the Micro800 Remote LCD (2080-REMLCD) module to allow easier configuration of such settings as IP address and functions as a simple IP65 text display. 1 Publication 2080-SG001D-EN-P - December 2013 2 Micro800 Programmable Controller Family Selection Guide Micro830TM controllers are designed for standalone machine control applications. They have flexible communications and I/O capabilities with up to five plug-ins. They come as a 10-, 16-, 24-, or 48-point form factors. Micro850TM expandable controllers are designed for applications that require more digital and analog I/O or higher performance analog I/O. They can support up to four expansion I/O. Micro850 controllers include additional communication connection options through an embedded 10/100 Base-T Ethernet port. Several Micro830 and Micro850 controllers support basic positioning through embedded pulse train outputs (PTO). These controllers also allow you to configure up to six high speed counters (HSC), and choose from nine HSC operation modes. HSC is supported on all Micro830 and Micro850 catalogs, except on 2080-LCxx-xxAWB. PTO is only supported on Micro830 and Micro850 catalog numbers that end in BB or VB. This selection guide serves to help you identify the right controller, plug-ins, expansion I/O, and accessories, based on your requirements. Choose a Micro800 Controller 1 Select a Micro800 controller (go to page 3) 2 Select a Micro810 3 controller (go to page 9) Select a Micro820 controller (go to page Select a Micro830 controller (go to page 19) Select a Micro850 controller (go to page 29) 4 Select Micro800 plug-ins and accessories (go to page 51) Select Micro850 expansion I/O (go to page 41) Publication 2080-SG001D-EN-P - December 2013 Micro800 Programmable Controller Family Selection Guide 3 Micro800 Controllers Comparison Features Attribute Micro810 Micro820 Micro830 Micro850 12-point 20-point 10-point 16-point 24-point 48-point 24-point 48-point Communication ports, embedded USB 2.0 (with USB adapter) 10/100 Base T Ethernet port (RJ-45) RS232/RS485 non-isolated combo serial USB 2.0 (non-isolated) RS232/RS485 non-isolated combo serial USB 2.0 (non-isolated) RS232/RS485 non-isolated combo serial 10/100 Base T Ethernet port (RJ-45) Embedded digital I/O 12 19 10 16 24 48 24 48 points(1) Base analog I/O channels Four 24V DC digital inputs are shared as 0...10V analog inputs (DC input models only) One 0...10V analog output Four 24V DC digital inputs can be configured as 0...10V analog inputs (DC input models only) and via plug-in modules Via plug-in modules Via plug-in modules and expansion I/O Number of plug-in modules 0 2 2 2 3 5 3 5 Maximum digital I/O(2) 12 35 26 32 48 88 132 Types of accessories or plug-ins supported · LCD display with backup memory module · USB adapter · Micro800 Remote LCD (2080-REMLCD) · All-plug-in modules except 2080-MEMBAKRTC (see page 51) All plug-in modules (see page 51) Expansion I/O supported -- -- -- All expansion I/O modules (see page 41) Power supply Embedded 120/240V Base unit has embedded 24V DC power supply, optional external 120/240V AC power AC and 12/24V DC supply available options Basic instruction speed 2.5 s per basic instruction 0.30 s per basic instruction Minimum scan/cycle time(3) <0.25 ms <4 ms <0.25 ms Software Connected Components Workbench (1) See Number and Types of Inputs/Outputs for Micro810, Micro820, Micro830, and Micro850 Catalogs on page 6. (2) For Micro820 and Micro830 controllers, the number of maximum digital I/O assumes 8-point digital I/O plug-ins (for example, 2080-IQ4OB4) are used on all available plug-in slots. For Micro850 controllers, the maximum number of digital I/O supported between the base, plug-ins, and expansion I/O is 132. (3) Including reading and writing I/O, program execution, and communications overhead. Publication 2080-SG001D-EN-P - December 2013 4 Micro800 Programmable Controller Family Selection Guide Micro800 Controller Programming Comparison (with Connected Components Workbench) Attribute Micro810 12-point Micro820 20-point Micro830 10/16-point Micro830 24-point Micro830 Micro850 Micro850 48-point 24-point 48-point Program steps(1) 2 K 10 K 4 K 10 K 10 K 10 K 10 K Data bytes 2 KB 20 KB 8 KB 20 KB 20 KB 20 KB 20 KB IEC 61131-3 languages Ladder diagram, function block diagram, structured text User defined function blocks Yes Floating point 32-bit and 64-bit PID Loop Control Yes (number limited only by memory) Embedded serial port protocols None Modbus RTU Master/Slave, ASCII/Binary, CIP Serial (1) Estimated Program and Data size are "typical" program steps and variables are created dynamically. 1 Program Step = 12 data bytes. The number of bytes per instruction can vary greatly from program to program and from programming language to programming language. Micro800 Communication Options Controller Micro810 Micro820 Micro830 Micro850 USB programming port Embedded Serial Port, Serial Port Plug-In CIP Serial Modbus RTU ASCII/Binary Yes (with adapter) No Yes (with 2080-REMLCD) Yes Master/Slave Yes Yes Yes Master/Slave Yes Yes Yes Master/Slave Yes Embedded Ethernet EtherNet/IP Modbus TCP Yes Yes No No Yes Yes Micro800 Controllers Analog I/O and TC/RTD Comparison Attribute Micro810 Micro820 Micro800 (with plug-ins) Micro850 (with expansion I/O) Performance level LOW LOW MEDIUM HIGH Isolation to controller None (increased noise immunity) None None Yes Resolution and Nominal Accuracy Analog Input: 10-bit, 5% (2% with calibration) Analog I/O: 12-bit, 5% (2% with calibration) Analog I/O: 12-bit, 1% TC/RTD: ±1 °C CJC for TC: ±1.2 °C Analog Input: 14-bit input, ±0.1% Analog Output: 12-bit output, 0.133%, current, 0.425% voltage TC: ±0.5 ... ±3.0 °C RTD: ±0.2 ... ±0.6 °C Input update rate and filtering Update rate only dependent on Update rate only dependent 200 ms/ch, 50/60 Hz program scan, limited filtering on program scan, limited filtering filtering 8 ms all channels with or without 50/60 Hz filtering Recommended maximum 10 m shielded cable length(1) 100 m (1) These numbers are guidelines only. Maximum cable length is dependent on the application and other factors such as cable type, installation, required accuracy, sensor, and so on. Publication 2080-SG001D-EN-P - December 2013 Micro800 Programmable Controller Family Selection Guide 5 Micro800 Power Requirements(1) Controller/Module Power Requirement Micro810 12-point (with or without LCD) 3 W (5V A for AC module) Micro820 20-point(2) (without plug-ins, max) 5.62 W Micro830 and Micro850 (without plug-in/expansion I/O) 10/16-point 5W 24-point 8W 48-point 11 W Plug-in modules, each 1.44 W Expansion I/O (system bus power consumption) 2085-IQ16 0.85 W 2085-IQ32T 0.95 W 2085-IA8 0.75 W 2085-IM8 0.75 W 2085-OA8 0.90 W 2085-OB16 1.00 W 2085-OV16 1.00 W 2085-OW8 1.80 W 2085-OW16 3.20 W 2085-IF4 1.70 W 2085-IF8 1.75 W 2085-OF4 3.70 W 2085-IRT4 2.00 W (1) When setting up a Micro800 system, verify that total power consumption of the controller, plug-in and expansion I/O does not exceed the output power capacity of the power supply used. See External Power Supply (2080-PS120-240VAC) on page 59 for power supply specifications. (2) Micro820 controllers require a maximum of 8.5 W with plug-ins. Publication 2080-SG001D-EN-P - December 2013 6 Micro800 Programmable Controller Family Selection Guide Number and Types of Inputs/Outputs Number and Types of Inputs/Outputs for Micro810, Micro820, Micro830, and Micro850 Catalogs Controller Catalogs Family Inputs 120V 120 / AC 240V AC 24V DC/ V AC Outputs 12V Relay 24V DC 24V DC Source DC Sink Micro810 2080-LC10-12QWB 8 4 2080-LC10-12AWA 8 4 2080-LC10-12QBB 8 4 2080-LC10-12DWD 84 Micro820 2080-LC20-20QBB 12 7 2080-LC20-20QWB 12 7 2080-LC20-20AWB 8 4 7 2080-LC20-20QBBR 12 7 2080-LC20-20QWBR 12 7 2080-LC20-20AWBR 8 4 7 Micro830 2080-LC30-10QWB 6 4 2080-LC30-10QVB 6 4 2080-LC30-16AWB 10 6 2080-LC30-16QWB 10 6 2080-LC30-16QVB 10 6 2080-LC30-24QWB 14 10 2080-LC30-24QVB 14 10 2080-LC30-24QBB 14 10 2080-LC30-48AWB 28 20 2080-LC30-48QWB 28 20 2080-LC30-48QVB 28 20 2080-LC30-48QBB 28 20 Micro850 2080-LC50-24AWB 14 10 2080-LC50-24QBB 14 10 2080-LC50-24QVB 14 10 2080-LC50-24QWB 14 10 2080-LC50-48AWB 28 20 2080-LC50-48QWB 28 20 2080-LC50-48QBB 28 20 2080-LC50-48QVB 28 20 (1) For Micro830 and Micro850, you need firmware revision 6.011 or later to use PWM output. (2) Maximum number of embedded HSC supported. Analog Out 0...10V DC 1 1 1 1 1 1 Analog In 0...10V (shared with DC In) 4 4 4 4 4 4 4 4 4 PTO/PWM Support(1) 1 (PWM) 1 (PWM) 1 (PTO/PWM) 1 (PTO/PWM) 2 (PTO/PWM) 2 (PTO/PWM) 3 (PTO/PWM) 3 (PTO/PWM) 2 (PTO/PWM) 2 (PTO/PWM) 3 (PTO/PWM) 3 (PTO/PWM) Embedded HSC Support(2) 2 2 2 2 4 4 4 6 6 6 4 4 4 6 6 6 Publication 2080-SG001D-EN-P - December 2013 Micro800 Programmable Controller Family Selection Guide 7 Micro800 Catalog Number Details 2080 - LC 30- 24 Q V B Bulletin Number Base Unit LC10 = Micro810 LC20 = Micro820 LC30 = Micro830 LC50 = Micro850 Number of I/O 10, 12, 16, 20, 24, 48 (1) Available for Micro810 only. Power Supply A(1) = 120/240V AC B = 24V DC D(1) = 12V DC Output Type B = 24V DC Source V = 24V DC Sink W = Relay Input Type A = 110V AC or 110/220V AC Q = 24V AC/DC D(1) = 12V DC Connected Components Workbench Software Connected Components WorkbenchTM is the programming and configuration software environment for the Micro800 controllers and our Connected Components products offering. It simplifies setup and usage, enabling applications ranging from simple Smart Relay up to Standalone Machine control. Visit the website for the most up-to-date product information, downloads and tools: http://ab.rockwellautomation.com/Programmable-Controllers/Connected-Co mponents-Workbench-Software. Attribute Delivery Packaging options Features Standard Edition Basic Download Connected Components Workbench Standard Edition for FREE at http://ab.rockwellautomation.com/Programmable-Controllers/Connected-Components-Workbench-Software. Available on DVD, orderable from Connected Components Workbench web page at http://ab.rockwellautomation.com/Programmable-Controllers/Connected-Components-Workbench-Software. · LD, FBD and ST editors · user-defined function blocks · No activation needed · Optional registration during installation (for product updates and notices) Publication 2080-SG001D-EN-P - December 2013 8 Micro800 Programmable Controller Family Selection Guide Developer Edition The Developer Edition offers the following additional programming features: User-defined Structures · You can combine different data types to create structures and then assign them to user-defined variables. · Structures are useful when you want a single variable to hold several related pieces of information. For example, you might want to define a structure to keep temperature ranges and alarm levels for a device rather than creating multiple variables. Spy Lists You can define spy lists to monitor changes in variables and function block instances in Connected Components Workbench programs. The Developer Edition installs the following additional software: · FactoryTalk® Activation Manager v3.60.00 (CPR 9 SR 6) · FactoryTalk Diagnostics v2.60.00 (CPR 9 SR 6) · Microsoft Help Viewer 1.1 Note: The Developer Edition requires an activation key. See the FactoryTalk Activation help for additional information on activating Rockwell Automation software products. Publication 2080-SG001D-EN-P - December 2013 Select a Micro810 Controller As the smallest of the Micro800 family, the Micro810 controller is available in a 12-point version, with two 8 A and two 4 A outputs that eliminate the need for external relays. The Micro810 features embedded smart relay function blocks that can be configured from a 1.5" LCD and keypad. The function blocks include Delay OFF/ON Timer, Time of Day, Time of Week and Time of Year for applications requiring a programmable timer and lighting control. Programming can also be done through a program download via USB programming port, using Connected Components Workbench Software. To help you select a Micro810 controller, consult the specifications for each catalog in the next section. Number and Types of Inputs/Outputs Catalog Number Power 2080-LC10-12QWB 2080-LC10-12AWA 2080-LC10-12QBB 2080-LC10-12DWD 24V DC 120...240V AC 12...24V DC 12V DC Inputs 120V AC 8 240V AC Outputs Analog In 0...10V 12...24V DC /V AC Relay 24 V DC SRC (shared with DC In) 8 4 4 4 8 4 4 8 4 4 9 Publication 2080-SG001D-EN-P - December 2013 10 Micro800 Programmable Controller Family Selection Guide Specifications(1) Attribute 2080-LC10-12AWA 2080-LC10-12QWB 2080-LC10-12DWD 2080-LC10-12QBB Number of I/O 8 Input (4 digital, 4 analog/digital, configurable) 4 Output Dimensions HxWxD 91 x 75 x 59 mm (3.58 x 2.95 x 2.32 in.) Supply voltage range 85...263V DC 20.4...26.4V DC 10.8V...13.2V DC 11.4V..26.4V DC Supply frequency range 47...63 Hz (AC supply) Voltage range 100...240V AC, 50/60 Hz 24V DC Class 2 12V DC Class 2 12/24V DC Class 2 Power consumption 5V A 3 W I/O rating Input: 120...240V AC Input: 24V DC, 8 mA Input: 12V DC, 8 mA Input: 24V DC, 8 mA Output: Relay 00 & 01: 8 A @ 240V AC, B300, R300, General Use Relay 02 & 03: 4 A @ 240V AC, C300, R150, General Use Output: 24V DC 1A, 25 °C, 24V DC 0.5A 55 °C Operating temperature 0...55 °C (32...131 °F) Shipping weight, approx. 0.203 kg (0.448 lb) Wire size 0.32...2.1 mm² (22...14 AWG) solid copper wire or 0.32...1.3 mm² (22...16 AWG) stranded copper wire rated @ 90 °C (194 °F ) insulation max. Wiring category 2 on signal ports 2 on power ports Wiring torque 1.085 Nm (8 lb-in.) Wire type use Copper Conductors only Fuse, type Rated 250V 3.15 A-RADIAL Enclosure type rating Meets IP20 North American temp code T5 Insulation stripping length 7 mm (0.28 in.) Isolation voltage 250V (continuous), Reinforced Insulation Type, I/O to Aux and Network, Inputs to Outputs. Type tested for 60 s 3250V DC, I/O to Aux and Network, Inputs to Outputs 250V (continuous), Reinforced Insulation Type, I/O to Aux and Network, Inputs to Outputs Type tested for 60 s @ 720V DC, Inputs to Aux and Network, 3250V DC Outputs to Aux and Network, Inputs to Outputs 50V (continuous), Reinforced Insulation Type, I/O to Aux and Network, Inputs to Outputs Type tested for 60 s @ 720V DC, I/O to Aux and Network, Inputs to Outputs AC input filter setting 16 ms for all embedded inputs (In Connected Components Workbench, go to the Embedded I/O configuration window to re-configure the filter setting for each input group) (1) See the Micro810 User Manual, publication 2080-UM001, for more Micro810 controller specifications. Publication 2080-SG001D-EN-P - December 2013 Micro800 Programmable Controller Family Selection Guide 11 Environmental Attribute Value Temperature, operating IEC 60068-2-1 (Test Ad, Operating Cold), IEC 60068-2-2 (Test Bd, Operating Dry Heat), IEC 60068-2-14 (Test Nb, Operating Thermal Shock): 0...55 °C (32...131 °F) Temperature, surrounding air, max 55 °C (131 °F) Temperature, storage IEC 60068-2-1 (Test Ab, Unpackaged Non-operating Cold), IEC 60068-2-2 (Test Bb, Unpackaged Non-operating Dry Heat), IEC 60068-2-14 (Test Na, Unpackaged Non-operating Thermal Shock): -40...85 °C (-40...185 °F) Relative humidity IEC 60068-2-30 (Test Db, Unpackaged Damp Heat): 5...95% non-condensing Vibration IEC 60068-2-6 (Test Fc, Operating): 2 g @ 10...500 Hz Shock, operating IEC 60068-2-27 (Test Ea, Unpackaged Shock): 30 g Shock, nonoperating IEC 60068-2-27 (Test Ea, Unpackaged Shock): 30 g (DIN Rail Mounted) 30 g (Panel Mounted) Emissions CISPR 11 Group 1, Class A ESD immunity IEC 61000-4-2: 4 kV contact discharges 8 kV air discharges Radiated RF immunity IEC 61000-4-3: 10V/m with 1 kHz sine-wave 80% AM from 80...2000 MHz 10V/m with 200 Hz 50% Pulse 100% AM @ 900 MHz 10V/m with 200 Hz 50% Pulse 100% AM @ 1890 MHz 3V/m with 1 kHz sine-wave 80% AM from 2000...2700 MHz EFT/B immunity IEC 61000-4-4: ±2 kV @ 5 kHz on power ports ±2 kV @ 5 kHz on signal ports Surge transient immunity IEC 61000-4-5: ±1 kV line-line(DM) and ±2 kV line-earth(CM) on power ports ±1 kV line-line(DM) and ±2 kV line-earth(CM) on signal ports ±2 kV line-earth(CM) on shielded ports Conducted RF immunity IEC 61000-4-6: 10V rms with 1 kHz sine-wave 80% AM from 150 kHz...80 MHz Voltage variation IEC 61000-4-11: 60% dip for 5 and 50 periods on AC supply ports 30% dip for 0.5 period at 0° and 180° on AC supply ports 100% dip for 0.5 period at 0° and 180° on AC supply ports ±10% fluctuations for 15 min on AC supply ports > 95% interruptions for 250 periods on AC supply ports Publication 2080-SG001D-EN-P - December 2013 12 Micro800 Programmable Controller Family Selection Guide Certifications Certification (when Value product is marked)(1) c-UL-us UL Listed Industrial Control Equipment, certified for US and Canada. See UL File E322657. UL Listed for Class I, Division 2 Group A,B,C,D Hazardous Locations, certified for U.S. and Canada. See UL File E334470. CE European Union 2004/108/EC EMC Directive, compliant with: EN 61000-6-2; Industrial Immunity EN 61000-6-4; Industrial Emissions EN 61131-2; Programmable Controllers (Clause 8, Zone A & B) EN 61131-2; Programmable Controllers (Clause 11) C-Tick Australian Radiocommunications Act, compliant with: AS/NZS CISPR 11; Industrial Emissions (1) See the Product Certification link at http://www.rockwellautomation.com/products/certification/ for Declaration of Conformity, Certificates, and other certification details. For relay life chart, see the Specifications section of the Micro810 User Manual, publication 2080-UM001. Publication 2080-SG001D-EN-P - December 2013 Select a Micro820 Controller As one of the smaller controllers in the Micro800 family, the Micro820 controller comes as a 20-point form factor, with six catalogs available for selection. The Micro820 controller is designed for smaller standalone machines and remote automation projects. It has the following features: · Two plug-in module slots · microSD card slot for project backup and restore, datalogging and recipe · Embedded 10/100 Base-t Ethernet port(RJ-45) · Support for Remote LCD module (2080-REMLCD) for configuration · Embedded non-isolated RS232/RS485 combo serial port · Modbus RTU protocol (serial port) · Modbus TCP support · EtherNet/IP support · CIP Serial support To help you select a Micro820 controller, consult the specifications for each catalog in the next section. 13 Publication 2080-SG001D-EN-P - December 2013 14 Micro800 Programmable Controller Family Selection Guide Number and Types of Inputs/Outputs for Micro820 Controllers Controller Catalogs Family Inputs 120V AC 120 /240V AC 24V DC Outputs Relay 24V DC Source 24V DC Sink Analog Out 0...10V DC Analog In 0...10V (shared with DC In) PWM Support Micro820 2080-LC20-20QBB 12 7 1 4 1 2080-LC20-20QWB 12 7 1 4 2080-LC20-20AWB 8 4 7 1 4 2080-LC20-20QBBR 12 7 1 4 1 2080-LC20-20QWBR 12 7 1 4 2080-LC20-20AWBR 8 4 7 1 4 General Specifications Attribute Number of I/O Dimension, HxWxD Shipping weight, approx. Wire size Wiring category(1) Wire type Specifications 2080-LC20-20AWB(R) 12 inputs, 8 outputs 90 x 104 x 75 mm (3.54 x 4.09 x 2.95 in.) 0.38 kg (0.83 lb) For fixed terminal blocks: 2080-LC20-20QBB(R) 2080-LC20-20QWB(R) Solid Stranded Min 0.14 mm2 (26 AWG) 0.14 mm2 (26 AWG) Max 2.5 mm2 (14 AWG) rated @ 90 °C (194 °F) insulation 1.5 mm2 (16 AWG) max For removable terminal blocks: Solid and Stranded Min 0.2 mm2 (24 AWG) Max 2.5 mm2 (14 AWG) rated @ 90 °C (194 °F) insulation max For RS232/RS485 serial port: Solid Stranded Min 0.14 mm2 (26 AWG) 0.14 mm2 (26 AWG) Max 1.5 mm2 (16 AWG) 1.0 mm2 (18 AWG) rated @ 90 °C (194 °F) insulation max 2 on signal ports 2 on power ports 2 on communication ports Use copper conductors or shielded cables Publication 2080-SG001D-EN-P - December 2013 Micro800 Programmable Controller Family Selection Guide 15 General Specifications Attribute Terminal screw torque 2080-LC20-20AWB(R) 2080-LC20-20QBB(R) 2080-LC20-20QWB(R) For removable and fixed terminal blocks: 0.5...0.6 Nm (4.4...5.3 lb-in.) using a 0.6 x 3.5 mm flat-blade screwdriver. Note: Use a handheld screwdriver to hold down the screws at the side. For RS232/RS485 serial port: 0.22...0.25 Nm (1.95...2.21 lb-in.) using 0.4 x 2.5 x 80 mm 2-component grip with non-slip grip screwdriver. Input circuit type 24V DC sink/source (standard) for 2080-LC20-20QWB(R), 2080-LC20-20QBB(R) 120V AC for 2080-LC20-20AWB(R) for Inputs 4...11 only Output circuit type Relay 24V DC source (standard and high-speed) Relay Power input 24V DC Power consumption 5.62 W (without plug-ins, max)...8.5 W (with plug-ins, max) Power dissipation 6W Power supply voltage range 20.4...26.4 V DC, Class 2 Auxiliary power supply output for 10V thermistor I/O rating Input: 120V AC 16 mA Output: 2 A, 240 V AC 2A, 24V DC Input: 24V DC, 8.8 mA Output:24V DC,1Aperpoint (Surrounding air temperature 30°C) 24 V DC, 0.3 A per point (Surrounding air temperature 65 °C) Input: 24V DC, 8.8 mA Output: 2 A, 240 V AC, 2A, 24V DC Isolation voltage 250V (continuous), Reinforced Insulation Type, Output to Aux and Network, Inputs to Outputs. 150V (continuous), Reinforced Insulation Type, Input to Aux and Network. Type tested for 60 s @ 3250 V DC Output to Aux and Network, Inputs to Outputs. Type tested for 60 s @ 1950 V DC Input to Aux and Network. 50V (continuous), Reinforced Insulation Type, I/O to Aux and Network, Inputs to Outputs. Type tested for 60 s @ 720 V DC, I/O to Aux and Network, Inputs to Outputs. 250V (continuous), Reinforced Insulation Type, Output to Aux and Network, Inputs to Outputs. 50V (continuous), Reinforced Insulation Type, Input to Aux and Network. Type tested for 60 s @ 720 V DC, Inputs to Aux and Network, 3250 V DC Outputs to Aux and Network, Inputs to Outputs. Pilot duty rating C300, R150 C300, R150 Insulation stripping length · 7 mm for the removable and fixed terminal blocks · 5 mm for the RS232/RS485 serial port Enclosure type rating Meets IP20 North American temp code T4 (1) Use this Conductor Category information for planning conductor routing. Refer to Industrial Automation Wiring and Grounding Guidelines, publication 1770-4.1. Publication 2080-SG001D-EN-P - December 2013 16 Micro800 Programmable Controller Family Selection Guide Environmental Specifications Attribute Value Temperature, operating IEC 60068-2-1 (Test Ad, Operating Cold), IEC 60068-2-2 (Test Bd, Operating Dry Heat), IEC 60068-2-14 (Test Nb, Operating Thermal Shock): -20...65 °C (-4...149 °F) Temperature, surrounding air, max 65 °C (149 °F) Temperature, nonoperating IEC 60068-2-1 (Test Ab, Unpackaged Nonoperating Cold), IEC 60068-2-2 (Test Bb, Unpackaged Nonoperating Dry Heat), IEC 60068-2-14 (Test Na, Unpackaged Nonoperating Thermal Shock): -40...85 °C (-40...185 °F) Relative humidity IEC 60068-2-30 (Test Db, Unpackaged Damp Heat): 5...95% non-condensing Vibration IEC 60068-2-6 (Test Fc, Operating): 2 g @ 10...500 Hz Shock, operating IEC 60068-2-27 (Test Ea, Unpackaged Shock): 25 g Shock, non-operating IEC 60068-2-27 (Test Ea, Unpackaged Shock): DIN mount: 25 g PANEL mount: 45 g Emissions CISPR 11 Group 1, Class A ESD immunity IEC 61000-4-2: 6 kV contact discharges 8 kV air discharges Radiated RF immunity IEC 61000-4-3: 10V/m with 1 kHz sine-wave 80% AM from 80...2000 MHz 10V/m with 200 Hz 50% Pulse 100% AM @ 900 MHz 10V/m with 200 Hz 50% Pulse 100% AM @ 1890 MHz 10V/m with 1 kHz sine-wave 80% AM from 2000...2700 MHz EFT/B immunity IEC 61000-4-4: ±2 kV @ 5 kHz on power ports ±2 kV @ 5 kHz on signal ports ±1 kV @ 5 kHz on communication ports Surge transient immunity IEC 61000-4-5: ±1 kV line-line(DM) and ±2 kV line-earth(CM) on power ports ±1 kV line-line(DM) and ±2 kV line-earth(CM) on signal ports ±1 kV line-earth(CM) on communication ports Conducted RF immunity IEC 61000-4-6: 10V rms with 1 kHz sine-wave 80% AM from 150 kHz...80 MHz Publication 2080-SG001D-EN-P - December 2013 Micro800 Programmable Controller Family Selection Guide 17 Certifications Certification (when product is marked)(1) c-UL-us Value UL Listed Industrial Control Equipment, certified for US and Canada. See UL File E322657. UL Listed for Class I, Division 2 Group A,B,C,D Hazardous Locations, certified for U.S. and Canada. See UL File E334470. CE European Union 2004/108/EC EMC Directive, compliant with: EN 61326-1; Meas./Control/Lab., Industrial Requirements EN 61000-6-2; Industrial Immunity EN 61000-6-4; Industrial Emissions EN 61131-2; Programmable Controllers (Clause 8, Zone A & B) European Union 2006/95/EC LVD, compliant with: EN 61131-2; Programmable Controllers (Clause 11) C-Tick Australian Radiocommunications Act, compliant with: AS/NZS CISPR 11; Industrial Emissions EtherNet/IP ODVA conformance tested to EtherNet/IP specifications KC Korean Registration of Broadcasting and Communications Equipment, compliant with: Article 58-2 of Radio Waves Act, Clause 3 (1) See the Product Certification link at http://www.rockwellautomation.com/products/certification for Declaration of Conformity, Certificates, and other certification details. For more information, see the Micro820 Programmable Controllers User Manual, publication 2080-UM005. Publication 2080-SG001D-EN-P - December 2013 18 Micro800 Programmable Controller Family Selection Guide Notes: Publication 2080-SG001D-EN-P - December 2013 Select a Micro830 Controller The Micro830 controller allows integration of as many as five plug-in modules. The plug-in modules enable machine builders to personalize the controllers to increase functionality. Most models offer removable terminal blocks and simplified communication via serial port. The controllers include: · up to six embedded High-Speed Counter inputs (HSC)(1) · 100 kHz speed HSC available on 24V DC models · up to three embedded Pulse Train Outputs (PTO) for basic positioning(2) · High speed input interrupts · Modbus RTU protocol (serial port) · CIP Serial to allow tighter integration with PanelView Component · Embedded USB programming and serial port (RS232/RS485) · Plug-in slots to customize according to needs To help you select a Micro830 controller, check out the specifications for each catalog in the next section. (1) Embedded HSC is supported on all Micro830 catalog numbers, except on 2080-LC30-xxAWB. (2) PTO is supported on Micro830 catalog numbers ending in BB or VB only. 19Publication 2080-SG001D-EN-P - December 2013 20 Micro800 Programmable Controller Selection Guide Inputs and Outputs Micro830 Controllers Number and Type of Inputs/Outputs Catalog Number Inputs 120V AC 2080-LC30-10QWB 2080-LC30-10QVB 2080-LC30-16AWB 10 2080-LC30-16QWB 2080-LC30-16QVB 2080-LC30-24QBB 2080-LC30-24QVB 2080-LC30-24QWB 2080-LC30-48AWB 28 2080-LC30-48QBB 2080-LC30-48QVB 2080-LC30-48QWB (1) Maximum number of HSC supported. Outputs 24V DC/V AC Relay 6 4 6 6 10 6 10 14 14 14 10 20 28 28 28 20 24V Sink 4 6 10 20 PTO/PWM Support 24V Source 1 HSC Support(1) 2 2 2 1 2 10 2 4 2 4 4 20 3 6 3 6 6 Micro830 Controllers General Features Attribute 10-point 2080-LC30-10QWB 2080-LC30-10QVB 16-point 2080-LC30-16AWB 2080-LC30-16QWB 2080-LC30-16QVB 24-point 2080-LC30-24QWB 2080-LC30-24QVB 2080-LC30-24QBB 48-point 2080-LC30-48AWB 2080-LC30-48QWB 2080-LC30-48QVB 2080-LC30-48QBB Number of I/O 10 (6 inputs, 4 outputs) 16 (10 inputs, 6 outputs) 24 (14 inputs, 10 outputs) 48 (28 inputs, 20 outputs) Dimensions, HxWxD 90 x 100 x 80 mm (3.54 x 3.94 x 3.15 in.) 90 x 100 x 80 mm (3.54 x 3.94 x 3.15 in.) 90 x 150 x 80 mm (3.54 x 5.91 x 3.15 in.) 90 x 230 x 80 mm (3.54 x 9.06 x 3.15 in.) Shipping weight, approx. 0.302 kg (0.666 lb) 0.302 kg (0.666 lb) 0.423 kg (0.933 lb) 0.725 kg (1.60 lb) Operating temperature Wire size Wiring category(1) -20...65 °C (-4...149 °F) 0.14...2.5 mm2 (26...14 AWG) solid copper wire or 0.14...1.5 mm2 (26...16 AWG) stranded copper wire rated @ 90 °C (194 °F) insulation max 2 on signal ports; 2 on power ports 0.2...2.5 mm2 (24...14 AWG) solid copper wire or 0.2...2.5 mm2 (24...14 AWG) stranded copper wire rated @ 90 °C (194 °F) insulation max Wire type Use copper conductors only Terminal screw torque, max 0.6 Nm (4.4 lb-in.) (using a 2.5 mm (0.10 in.) flat-blade screwdriver) Power consumption 7.88 W 12.32 W 18.2 W Power supply voltage range 20.4...26.4V DC Class 2 Insulation stripping length 7 mm (0.28 in.) Enclosure type rating Meets IP20 North American temp code T4 (1) Use this Conductor Category information for planning conductor routing. Refer to Industrial Automation Wiring and Grounding Guidelines, publication 1770-4.1. Publication 2080-SG001D-EN-P - December 2013 Micro800 Programmable Controller Selection Guide 21 Micro830 Controllers 10- and 16-Point Controllers General Specifications 10-point controllers Attribute 2080-LC30-10QWB 2080-LC30-10QVB Input circuit type 12/24V sink/source (standard) 24V sink/source (high-speed) Output circuit type Relay 24V DC sink transistor standard and high-speed Event input interrupt support Yes I/O rating Input 24V DC, 8.8 mA Output 2 A, 240V AC, general use Input 24V DC, 8.8 mA Output 2 A, 24V DC, 1 A per point (Surrounding air temperature 30 °C) 24V DC, 0.3 A per point (Surrounding air temperature 65 °C) Isolation voltage 250V (continuous), Reinforced Insulation Type, Outputs to Aux and Network, Inputs to Outputs Type tested for 60 s @ 720V DC, Inputs to Aux and Network, 3250V DC Outputs to Aux and Network, Inputs to Outputs 50V (continuous), Reinforced Insulation Type, I/O to Aux and Network, Inputs to Outputs Type tested for 60 s @ 720V DC, I/O to Aux and Network, Inputs to Outputs Pilot duty rating C300, R150 -- General Specifications 16-point controllers Attribute Input circuit type 2080-LC30-16AWB 120V AC Output circuit type Relay Event input interrupt Yes support 2080-LC30-16QWB 12/24V sink/source (standard) 24V sink/source (high-speed) 2080-LC30-16QVB 12/24V DC sink transistor standard and high-speed Publication 2080-SG001D-EN-P - December 2013 22 Micro800 Programmable Controller Selection Guide General Specifications 16-point controllers Attribute I/O rating Isolation voltage Pilot duty rating 2080-LC30-16AWB 2080-LC30-16QWB 2080-LC30-16QVB Input 120V AC, 16 mA Output 2 A, 240V AC, general use Input 24V DC, 8.8 mA Output 2 A, 240V AC, general use Input 24V DC, 8.8 mA Output 24V DC, 1 A per point (Surrounding air temperature 30 °C) 24 V DC, 0.3 A per point (Surrounding air temperature 65 °C) 250V (continuous), Reinforced Insulation Type, Outputs to Aux and Network, Inputs to Outputs 2080-LC30-16AWB: Type tested for 60 s @ 3250V DC I/O to Aux and Network, Inputs to Outputs 2080-LC30-16QWB: Type tested for 60 s @ 720V DC, Inputs to Aux and Network, 3250V DC Outputs to Aux and Network, Inputs to Outputs 50V (continuous), Reinforced Insulation Type, I/O to Aux and Network, Inputs to Outputs Type tested for 60s @ 720V DC, I/O to Aux and Network, Inputs to Outputs C300, R150 -- Environmental Specifications Attribute Temperature, operating Temperature, surrounding air, max Temperature, non-operating Relative humidity Vibration Shock, operating Shock, non-operating Emissions ESD immunity Radiated RF immunity EFT/B immunity Surge transient immunity Value IEC 60068-2-1 (Test Ad, Operating Cold), IEC 60068-2-2 (Test Bd, Operating Dry Heat), IEC 60068-2-14 (Test Nb, Operating Thermal Shock): -20...65 °C (-4...149 °F) 65 °C (149 °F) IEC 60068-2-1 (Test Ab, Unpackaged Nonoperating Cold), IEC 60068-2-2 (Test Bb, Unpackaged Nonoperating Dry Heat), IEC 60068-2-14 (Test Na, Unpackaged Nonoperating Thermal Shock): -40...85 °C (-40...185 °F) IEC 60068-2-30 (Test Db, Unpackaged Damp Heat): 5...95% non-condensing IEC 60068-2-6 (Test Fc, Operating): 2 g @ 10...500 Hz IEC 60068-2-27 (Test Ea, Unpackaged Shock): 25 g IEC 60068-2-27 (Test Ea, Unpackaged Shock): DIN mount: 25 g PANEL mount: 45 g CISPR 11 Group 1, Class A IEC 61000-4-2: 6 kV contact discharges 8 kV air discharges IEC 61000-4-3: 10V/m with 1 kHz sine-wave 80% AM from 80...2000 MHz 10V/m with 200 Hz 50% Pulse 100% AM @ 900 MHz 10V/m with 200 Hz 50% Pulse 100% AM @ 1890 MHz 10V/m with 1 kHz sine-wave 80% AM from 2000...2700 MHz IEC 61000-4-4: ±2 kV at 5 kHz on power ports ±2 kV at 5 kHz on signal ports IEC 61000-4-5: ±1 kV line-line(DM) and ±2 kV line-earth(CM) on power ports ±1 kV line-line(DM) and ±2 kV line-earth(CM) on signal ports Publication 2080-SG001D-EN-P - December 2013 Micro800 Programmable Controller Selection Guide 23 Environmental Specifications Attribute Conducted RF immunity Value IEC 61000-4-6: 10V rms with 1 kHz sine-wave 80% AM from 150 kHz...80 MHz Certifications Certification (when Value product is marked)(1) c-UL-us UL Listed Industrial Control Equipment, certified for US and Canada. See UL File E322657. UL Listed for Class I, Division 2 Group A,B,C,D Hazardous Locations, certified for U.S. and Canada. See UL File E334470. CE European Union 2004/108/EC EMC Directive, compliant with: EN 61326-1; Meas./Control/Lab., Industrial Requirements EN 61000-6-2; Industrial Immunity EN 61000-6-4; Industrial Emissions EN 61131-2; Programmable Controllers (Clause 8, Zone A & B) European Union 2006/95/EC LVD, compliant with: EN 61131-2; Programmable Controllers (Clause 11) C-Tick Australian Radiocommunications Act, compliant with: AS/NZS CISPR 11; Industrial Emissions (1) See the Product Certification link at http://www.rockwellautomation.com/products/certification/ for Declaration of Conformity, Certificates, and other certification details. Publication 2080-SG001D-EN-P - December 2013 24 Micro800 Programmable Controller Selection Guide Micro830 24-Point Controllers General Specifications 24-point controllers Attribute Input circuit type Output circuit type Event input interrupt support I/O rating Isolation voltage Pilot duty rating 2080-LC30-24QWB 24V DC sink/source standard and high-speed Relay Yes 2080-LC30-24QVB 24V DC sink standard and high-speed 2080-LC30-24QBB 24V DC source standard and high-speed Input 24V DC, 8.8 mA Output 2 A, 240 V AC, general use 250V (continuous), Reinforced Insulation Type, Outputs to Aux and Network, Inputs to Outputs Type tested for 60 s @ 720V DC, Inputs to Aux and Network, 3250V DC Outputs to Aux and Network, Inputs to Outputs C300, R150 (2080-LC30-24QWB only) Input 24V DC, 8.8 mA Output 24V DC, Class 2, 1 A per point (Surrounding air temperature 30 °C) 24V DC, Class 2, 0.3 A per point (Surrounding air temperature 65 °C) 50V (continuous), Reinforced Insulation Type, I/O to Aux and Network, Inputs to Outputs Type tested for 60 s @ 720V DC, I/O to Aux and Network, Inputs to Outputs -- Environmental Specifications Attribute Value Temperature, operating IEC 60068-2-1 (Test Ad, Operating Cold), IEC 60068-2-2 (Test Bd, Operating Dry Heat), IEC 60068-2-14 (Test Nb, Operating Thermal Shock): -20...65 °C (-4...149 °F) Temperature, surrounding 65 °C (149 °F) air, max Temperature, non-operating IEC 60068-2-1 (Test Ab, Unpackaged Nonoperating Cold), IEC 60068-2-2 (Test Bb, Unpackaged Nonoperating Dry Heat), IEC 60068-2-14 (Test Na, Unpackaged Nonoperating Thermal Shock): -40...85 °C (-40...185 °F) Relative humidity IEC 60068-2-30 (Test Db, Unpackaged Damp Heat): 5...95% non-condensing Publication 2080-SG001D-EN-P - December 2013 Micro800 Programmable Controller Selection Guide 25 Environmental Specifications Attribute Vibration Shock, operating Shock, non-operating Emissions ESD immunity Radiated RF immunity EFT/B immunity Surge transient immunity Conducted RF immunity Value IEC 60068-2-6 (Test Fc, Operating): 2 g @ 10...500 Hz IEC 60068-2-27 (Test Ea, Unpackaged Shock): 25 g IEC 60068-2-27 (Test Ea, Unpackaged Shock): DIN mount: 25 g PANEL mount: 35 g CISPR 11 Group 1, Class A IEC 61000-4-2: 6 kV contact discharges 8 kV air discharges IEC 61000-4-3: 10V/m with 1 kHz sine-wave 80% AM from 80...2000 MHz 10V/m with 200 Hz 50% Pulse 100% AM @ 900 MHz 10V/m with 200 Hz 50% Pulse 100% AM @ 1890 MHz 10V/m with 1 kHz sine-wave 80% AM from 2000...2700 MHz IEC 61000-4-4: ±2 kV at 5 kHz on power ports ±2 kV at 5 kHz on signal ports IEC 61000-4-5: ±1 kV line-line(DM) and ±2 kV line-earth(CM) on power ports ±1 kV line-line(DM) and ±2 kV line-earth(CM) on signal ports IEC 61000-4-6: 10V rms with 1 kHz sine-wave 80% AM from 150 kHz...80 MHz Certifications Certification (when product is marked)(1) c-UL-us Value UL Listed Industrial Control Equipment, certified for US and Canada. See UL File E322657. UL Listed for Class I, Division 2 Group A,B,C,D Hazardous Locations, certified for U.S. and Canada. See UL File E334470. CE European Union 2004/108/EC EMC Directive, compliant with: EN 61326-1; Meas./Control/Lab., Industrial Requirements EN 61000-6-2; Industrial Immunity EN 61000-6-4; Industrial Emissions EN 61131-2; Programmable Controllers (Clause 8, Zone A & B) European Union 2006/95/EC LVD, compliant with: EN 61131-2; Programmable Controllers (Clause 11) C-Tick Australian Radiocommunications Act, compliant with: AS/NZS CISPR 11; Industrial Emissions (1) See the Product Certification link at http://www.rockwellautomation.com/products/certification/ for Declaration of Conformity, Certificates, and other certification details. Publication 2080-SG001D-EN-P - December 2013 26 Micro800 Programmable Controller Selection Guide Micro830 48-Point Controllers General Specifications 48-point controllers Attribute 2080-LC30-48AWB 2080-LC30-48QWB 2080-LC30-48QVB 2080-LC30-48QBB Input circuit type 120V AC 24V DC sink/source standard and high-speed Output circuit type Relay 24V DC sink standard and high-speed 24V DC source standard and high-speed Event input interrupt Yes, inputs 0...15 only support I/O rating Input 120V AC, 16 mA Output 2 A, 240V AC, general use Input 24V DC, 8.8 mA Output 2 A, 240V AC, general use Input 24V DC, 8.8 mA Output 24V DC, 1 A per point (Surrounding air temperature 30 °C) 24 V DC, 0.3 A per point (Surrounding air temperature 65 °C) Pilot duty rating C300, R150 Isolation voltage 250V (continuous), Reinforced Insulation Type, Outputs to Aux and Network, Inputs to Outputs Type tested for 60 s @ 3250V DC I/O to Aux and Network, Inputs to Outputs 250V (continuous), Reinforced Insulation Type, Outputs to Aux and Network, Inputs to Outputs Type tested for 60 s @ 720V DC, Inputs to Aux and Network, 3250V DC Outputs to Aux and Network, Inputs to Outputs 50V (continuous), Reinforced Insulation Type, I/O to Aux and Network, Inputs to Outputs Type tested for 60 s @ 720V DC, I/O to Aux and Network, Inputs to Outputs Publication 2080-SG001D-EN-P - December 2013 Micro800 Programmable Controller Selection Guide 27 Environmental Specifications Attribute Temperature, operating Temperature, surrounding air, max Temperature, non-operating Relative humidity Vibration Shock, operating Shock, non-operating Emissions ESD immunity Radiated RF immunity EFT/B immunity Surge transient immunity Conducted RF immunity Value IEC 60068-2-1 (Test Ad, Operating Cold), IEC 60068-2-2 (Test Bd, Operating Dry Heat), IEC 60068-2-14 (Test Nb, Operating Thermal Shock): -20...65 °C (-4...149 °F) 65 °C (149 °F) IEC 60068-2-1 (Test Ab, Unpackaged Nonoperating Cold), IEC 60068-2-2 (Test Bb, Unpackaged Nonoperating Dry Heat), IEC 60068-2-14 (Test Na, Unpackaged Nonoperating Thermal Shock): -40...85 °C (-40...185 °F) IEC 60068-2-30 (Test Db, Unpackaged Damp Heat): 5...95% non-condensing IEC 60068-2-6 (Test Fc, Operating): 2 g @ 10...500 Hz IEC 60068-2-27 (Test Ea, Unpackaged Shock): 25 g IEC 60068-2-27 (Test Ea, Unpackaged Shock): DIN mount: 25 g PANEL mount: 35 g CISPR 11 Group 1, Class A IEC 61000-4-2: 6 kV contact discharges 8 kV air discharges IEC 61000-4-3: 10V/m with 1 kHz sine-wave 80% AM from 80...2000 MHz 10V/m with 200 Hz 50% Pulse 100% AM @ 900 MHz 10V/m with 200 Hz 50% Pulse 100% AM @ 1890 MHz 10V/m with 1 kHz sine-wave 80% AM from 2000...2700 MHz IEC 61000-4-4: ±2 kV @ 5 kHz on power ports ±2 kV @ 5 kHz on signal ports IEC 61000-4-5: ±1 kV line-line(DM) and ±2 kV line-earth(CM) on power ports ±1 kV line-line(DM) and ±2 kV line-earth(CM) on signal ports IEC 61000-4-6: 10V rms with 1 kHz sine-wave 80% AM from 150 kHz...80 MHz Publication 2080-SG001D-EN-P - December 2013 28 Micro800 Programmable Controller Selection Guide Certifications Certification (when product is marked)(1) c-UL-us Value UL Listed Industrial Control Equipment, certified for US and Canada. See UL File E322657. UL Listed for Class I, Division 2 Group A,B,C,D Hazardous Locations, certified for U.S. and Canada. See UL File E334470. CE European Union 2004/108/EC EMC Directive, compliant with: EN 61326-1; Meas./Control/Lab., Industrial Requirements EN 61000-6-2; Industrial Immunity EN 61000-6-4; Industrial Emissions EN 61131-2; Programmable Controllers (Clause 8, Zone A & B) European Union 2006/95/EC LVD, compliant with: EN 61131-2; Programmable Controllers (Clause 11) C-Tick Australian Radiocommunications Act, compliant with: AS/NZS CISPR 11; Industrial Emissions (1) See the Product Certification link at http://www.rockwellautomation.com/products/certification/ for Declaration of Conformity, Certificates, and other certification details. For relay life chart, see the Specifications section of the Micro830 and Micro850 User Manual, publication 2080-UM002. Embedded Serial Port Cables Embedded Serial Port Cable Selection Chart Connectors 8-pin Mini DIN to 8-pin Mini DIN 8-pin Mini DIN to 8-pin Mini DIN Length Cat. No. 0.5 m (1.5 ft) 1761-CBL-AM00(1) 2 m (6.5 ft) 1761-CBL-HM02(1) (1) Series C or later for Class 1 Div 2 applications. Connectors 8-pin Mini DIN to 9-pin D Shell 8-pin Mini DIN to 9-pin D Shell 8-pin Mini DIN to 6-pin RS-485 terminal block Length Cat. No. 0.5 m (1.5 ft) 1761-CBL-AP00(1) 2 m (6.5 ft) 1761-CBL-PM02(1) 30 cm (11.8 in.) 1763-NC01 series A Publication 2080-SG001D-EN-P - December 2013 Select a Micro850 Controller A Micro850 controller with a power supply, plug-in modules, and four expansion I/O modules attached Micro850 controllers are suitable for applications that require more digital and analog I/O or higher performance analog I/O. These controllers can support up to four expansion I/O. It comes in a 24-point and 48-point form factor with an embedded Ethernet port. Micro850 controllers include: · Expansion I/O support · up to six embedded High-Speed Counter inputs (HSC)(1) · 100 kHz speed HSC available on 24V DC models · up to three embedded Pulse Train Outputs (PTO)(2) for basic positioning · High speed input interrupts · Modbus RTU protocol (serial port) · Modbus/TCP support · EtherNet/IP support · CIP Serial support · Embedded USB programming and serial port (RS232/485) · Embedded 10/100 Base-T Ethernet port (RJ45) · Plug-in slots to customize according to needs To help you select a Micro850 controller, see the following specifications. (1) Embedded HSC is supported on all Micro850 catalog numbers, except on 2080-LC50-xxAWB. (2) PTO is supported on Micro850 catalog numbers ending in BB or VB. 29 Publication 2080-SG001D-EN-P - December 2013 30 Micro800 Programmable Controller Family Selection Guide Micro850 Controllers Number and Types of Inputs and Outputs Catalog Number Inputs 120V 24V AC DC/ V AC 2080-LC50-24AWB 14 2080-LC50-24QBB 14 2080-LC50-24QVB 14 2080-LC50-24QWB 14 2080-LC50-48AWB 28 2080-LC50-48QBB 28 2080-LC50-48QVB 28 2080-LC50-48QWB 28 (1) Maximum number of HSC supported. Outputs Relay 24V Sink 10 10 10 20 20 20 PTO/ PWM 24V Support Source HSC Support(1) 10 2 4 2 4 4 20 3 6 3 6 6 Micro850 24-Point Controllers General Specifications 2080-LC50-24AWB, 2080-LC50-24QWB, 2080-LC50-24QVB, 2080-LC50-24QBB Attribute Number of I/O Dimensions, HxWxD Shipping weight, approx. 2080-LC50-24AWB 2080-LC50-24QWB 24 (14 inputs, 10 outputs) 90 x 158 x 80 mm (3.54 x 6.22 x 3.15 in.) 0.423 kg (0.933 lb) 2080-LC50-24QVB 2080-LC50-24QBB Publication 2080-SG001D-EN-P - December 2013 Micro800 Programmable Controller Family Selection Guide 31 General Specifications 2080-LC50-24AWB, 2080-LC50-24QWB, 2080-LC50-24QVB, 2080-LC50-24QBB Attribute Wire size 2080-LC50-24AWB 2080-LC50-24QWB Solid Stranded Min 0.2 mm2 (24 AWG) 0.2 mm2 (24 AWG) Max 2.5 mm2 (14 AWG) 2.5 mm2 (14 AWG) 2080-LC50-24QVB 2080-LC50-24QBB rated @ 90 °C (194 °F) insulation max Wiring category(1) 2 on signal ports 2 on power ports 2 on communication ports Wire type Use copper conductors only Terminal screw torque 0.6 Nm (4.4 lb-in.) max (using a 2.5 mm (0.10 in.) flat-blade screwdriver) Input circuit type 120V AC 24V DC sink/source standard and high-speed Output circuit type Relay 24V DC sink standard and high-speed 24V DC source standard and high-speed Power consumption 28 W Power supply voltage range 20.4...26.4V DC Class 2 I/O rating Input 120V AC 16 mA Output 2 A, 240 V AC, 24V DC Input 24V, 8.8 mA Output 2 A, 240 V AC, 24V DC Input 24V, 8.8 mA Output 24V DC, Class 2, 1 A per point (surrounding air temperature 30 °C) 24 V DC, Class 2, 0.3 A per point (surrounding air temperature 65 °C) Isolation voltage 250V (continuous), Reinforced Insulation Type, Output to Aux and Network, Inputs to Outputs. Type tested for 60 s @ 3250V DC Output to Aux and Network, Inputs to Outputs 150V (continuous), Reinforced Insulation Type, Input to Aux and Network. Type tested for 60 s @ 1950V DC Input to Aux and Network 250V (continuous), Reinforced Insulation Type, I/O to Aux and Network, Inputs to Outputs. Type tested for 60 s @ 3250V DC Output to Aux and Network, Inputs to Outputs. 50V (continuous), Reinforced Insulation Type, Input to Aux and Network Type tested for 60 s @ 720V DC, Inputs to Aux and Network. 50V (continuous), Reinforced Insulation Type, I/O to Aux and Network, Inputs to Outputs. Type tested for 60 s @ 720V DC, I/O to Aux and Network, Inputs to Outputs. Pilot duty rating C300, R150 -- Insulation stripping length 7 mm (0.28 in.) Enclosure type rating Meets IP20 North American temp code T4 (1) Use this Conductor Category information for planning conductor routing. Refer to Industrial Automation Wiring and Grounding Guidelines, publication 1770-4.1. Publication 2080-SG001D-EN-P - December 2013 32 Micro800 Programmable Controller Family Selection Guide DC Input Specifications 2080-LC50-24QBB, 2080-LC50-24QVB, 2080-LC50-24QWB Attribute Number of Inputs Voltage category Input group to backplane isolation On-state voltage range Off-state voltage, max Off-state current, max On-state current, min On-state current, nom On-state current, max Nominal impedance IEC input compatibility High-Speed DC Input (Inputs 0...7) Standard DC Input (Inputs 8 and higher) 8 6 24V sink/source Verified by one of the following dielectric tests: 720V DC for 2 s 50V DC working voltage (IEC Class 2 reinforced insulation) 16.8...26.4V DC @ 65 °C (149 °F) 10...26.4V DC @ 65 °C (149°F) 16.8...30.0V DC @ 30 °C (86 °F) 10...30.0V DC @ 30 °C (86°F) 5V DC 1.5 mA 5.0 mA @ 16.8V DC, min 1.8 mA @ 10V DC, min 7.6 mA @ 24V DC, nom 6.15 mA @ 24V DC, nom 12.0 mA @ 30V DC, max 12.0 mA @ 30V DC, max 3 k 3.74 k Type 3 Publication 2080-SG001D-EN-P - December 2013 Micro800 Programmable Controller Family Selection Guide 33 AC Input Specifications 2080-LC50-24AWB Attribute Number of inputs On-state voltage, min On-state voltage, max On-state current, min On-state current, max Input frequency, nom Input frequency, min Input frequency, max Off-state voltage, max Off-state current, max Inrush current, max Inrush delay time constant max IEC input compatibility Value 14 79V AC, min 132V AC, max 5 mA 16 mA 50/60 Hz 47 Hz 63 Hz, max 20V AC @ 120V AC 2.5 mA @ 120V AC 250 mA @ 120V AC 22 ms Type 3 Output Specifications Attribute 2080-LC50-24QWB, 2080-LC50-24AWB 2080-LC50-24QVB, 2080-LC50-24QBB Relay Output Hi-Speed Output (Outputs 0...1) Standard Output (Outputs 2 and higher) Number of outputs 10 2 8 Output voltage, min 5V DC, 5V AC 10.8V DC 10V DC Output voltage, max 125V DC, 265V AC 26.4V DC 26.4V DC Load current, min 10 mA Load current, continuous, max Refer to Relay Contacts Ratings on page 33 100 mA (high-speed operation) 1.0 A @ 30 °C 1.0 A @ 30 °C 0.3 A @ 65 °C (standard operation) 0.3 A @ 65 °C (standard operation) Surge current, per point Refer to Relay Contacts Ratings on page 33 4.0 A for 10 ms every 1 s @ 30 °C; every 2 s @ 65 °C(1) Current, per common, max 5 A -- -- Turn on time/ Turn off time, max 10 ms 2.5 s 0.1 ms 1 ms (1) Applies for general purpose operation only; does not apply for high-speed operation. Relay Contacts Ratings Maximum Volts 120V AC 240V AC 24V DC 125V DC Amperes Make 15 A 7.5 A 1.0 A 0.22 A Break 1.5 A 0.75 A Amperes Continuous 2.0 A 1.0 A Volt-Amperes Make Break 1800V A 180V A 28V A Publication 2080-SG001D-EN-P - December 2013 34 Micro800 Programmable Controller Family Selection Guide For relay life chart, see the Specifications section of the Micro830 and Micro850 User Manual, publication 2080-UM002. Environmental Specifications Attribute Value Temperature, operating IEC 60068-2-1 (Test Ad, Operating Cold), IEC 60068-2-2 (Test Bd, Operating Dry Heat), IEC 60068-2-14 (Test Nb, Operating Thermal Shock): -20...65 °C (-4...149 °F) Temperature, surrounding 65 °C (149 °F) air, max Temperature, non-operating IEC 60068-2-1 (Test Ab, Unpackaged Nonoperating Cold), IEC 60068-2-2 (Test Bb, Unpackaged Nonoperating Dry Heat), IEC 60068-2-14 (Test Na, Unpackaged Nonoperating Thermal Shock): -40...85 °C (-40...185 °F) Relative humidity IEC 60068-2-30 (Test Db, Unpackaged Damp Heat): 5...95% non-condensing Vibration IEC 60068-2-6 (Test Fc, Operating): 2 g @ 10...500 Hz Shock, operating IEC 60068-2-27 (Test Ea, Unpackaged Shock): 25 g Shock, non-operating IEC 60068-2-27 (Test Ea, Unpackaged Shock): DIN mount: 25 g PANEL mount: 35 g Emissions CISPR 11 Group 1, Class A ESD immunity IEC 61000-4-2: 6 kV contact discharges 8 kV air discharges Radiated RF immunity IEC 61000-4-3: 10V/m with 1 kHz sine-wave 80% AM from 80...2000 MHz 10V/m with 200 Hz 50% Pulse 100% AM @ 900 MHz 10V/m with 200 Hz 50% Pulse 100% AM @ 1890 MHz 10V/m with 1 kHz sine-wave 80% AM from 2000...2700 MHz EFT/B immunity IEC 61000-4-4: ±2 kV @ 5 kHz on power ports ±2 kV @ 5 kHz on signal ports ±1 kV @ 5 kHz on communication ports Surge transient immunity IEC 61000-4-5: ±1 kV line-line(DM) and ±2 kV line-earth(CM) on AC power ports ±1 kV line-line(DM) and ±2 kV line-earth(CM) on signal ports ±1 kV line-earth(CM) on communication ports Conducted RF immunity IEC 61000-4-6: 10V rms with 1 kHz sine-wave 80% AM from 150 kHz...80 MHz Publication 2080-SG001D-EN-P - December 2013 Micro800 Programmable Controller Family Selection Guide 35 Certifications Certification (when product is marked)(1) c-UL-us Value UL Listed Industrial Control Equipment, certified for US and Canada. See UL File E322657. UL Listed for Class I, Division 2 Group A,B,C,D Hazardous Locations, certified for U.S. and Canada. See UL File E334470. CE European Union 2004/108/EC EMC Directive, compliant with: EN 61326-1; Meas./Control/Lab., Industrial Requirements EN 61000-6-2; Industrial Immunity EN 61000-6-4; Industrial Emissions EN 61131-2; Programmable Controllers (Clause 8, Zone A & B) European Union 2006/95/EC LVD, compliant with: EN 61131-2; Programmable Controllers (Clause 11) C-Tick Australian Radiocommunications Act, compliant with: AS/NZS CISPR 11; Industrial Emissions EtherNet/IP ODVA conformance tested to EtherNet/IP specifications KC Korean Registration of Broadcasting and Communications Equipment, compliant with: Article 58-2 of Radio Waves Act, Clause 3 (1) See the Product Certification link at http://www.rockwellautomation.com/products/certification for Declaration of Conformity, Certificates, and other certification details. Micro850 48-Point Controllers General Specifications 2080-LC50-48AWB, 2080-LC50-48QWB, 2080-LC50-48QVB, 2080-LC50-48QBB Attribute Number of I/O Dimensions, HxWxD Shipping weight, approx. 2080-LC50-48AWB 2080-LC50-48QWB 48 (28 inputs, 20 outputs) 90 x 238 x 80 mm (3.54 x 9.37 x 3.15 in.) 0.725 kg (1.60 lb) 2080-LC50-48QVB 2080-LC50-48QBB Publication 2080-SG001D-EN-P - December 2013 36 Micro800 Programmable Controller Family Selection Guide General Specifications 2080-LC50-48AWB, 2080-LC50-48QWB, 2080-LC50-48QVB, 2080-LC50-48QBB Attribute Wire size 2080-LC50-48AWB Min 2080-LC50-48QWB Max 2080-LC50-48QVB 2080-LC50-48QBB Solid 0.2 mm2 (24 AWG) 2.5 mm2 (14 AWG) rated @ 90°C (194 °F), insulation max. Stranded 0.2 mm2 (24 AWG) 2.5 mm2 (14 AWG) Wiring category(1) 2 on signal ports 2 on power ports 2 on communication ports Wire type Use copper conductors only Terminal screw torque 0.4...0.5 Nm (3.5...4.4 lb-in.) (using a 0.6 x 3.5 mm flat-blade screwdriver) Input circuit type 120V AC 24V DC sink/source standard and high-speed Output circuit type Relay 24V DC sink standard 24V DC source standard and and high-speed high-speed Power consumption 33 W Power supply voltage range 20.4...26.4V DC Class 2 I/O rating Input 120V AC, 16 mA Output 2 A, 240V AC, 2 A, 24V DC Input 24V DC, 8.8 mA Output 2 A, 240V AC, 2 A, 24V DC Input 24V DC, 8.8 mA Output 24V DC, 1 A per point (Surrounding air temperature 30 °C) 24V DC, 0.3 A per point (Surrounding air temperature 65 °C) Insulation stripping length 7 mm (0.28 in.) Enclosure type rating Meets IP20 Pilot duty rating C300, R150 -- Isolation voltage 250V (continuous), Reinforced Insulation Type, Output to Aux and Network, Inputs to Outputs Type tested for 60 s @ 3250V DC Output to Aux and Network, Inputs to Outputs. 250V (continuous), Reinforced 50V (continuous), Reinforced Insulation Type, I/O to Insulation Type, I/O to Aux and Aux and Network, Inputs to Outputs Network, Inputs to Outputs Type tested for 60 s @ 720V DC, I/O to Aux and Type tested for 60 s @ 3250V DC Network, Inputs to Outputs. Output to Aux and Network, Inputs to Outputs. 150V (continuous), Reinforced Insulation Type, Input to Aux and Network Type tested for 60 s @ 1950V DC Input to Aux and Network 50V (continuous), Reinforced Insulation Type, Input to Aux and Network Type tested for 60 s @ 720V DC, Inputs to Aux and Network North American temp code T4 (1) Use this Conductor Category information for planning conductor routing. Refer to Industrial Automation Wiring and Grounding Guidelines, publication 1770-4.1. Input Specifications Attribute Number of Inputs Input group to backplane isolation Voltage category Operating voltage range 2080-LC50-48AWB 120V AC Input 28 Verified by the following dielectric tests: 1950V AC for 2 s 150V working voltage (IEC Class 2 reinforced insulation) 110V AC 132V, 60Hz AC max 2080-LC50-48QWB / 2080-LC50-48QVB / 2080-LC50-48QBB High-Speed DC Input (Inputs 0...11) Standard DC Input (Inputs 12 and higher) 12 16 Verified by the following dielectric tests: 720V DC for 2 s 50V DC working voltage (IEC Class 2 reinforced insulation) 24V DC sink/source 16.8...26.4V DC @ 65 °C (149 °F) 16.8...30.0V DC @ 30 °C (86 °F) 10...26.4V DC @ 65 °C (149 °F) 10...30.0V DC @ 30 °C (86 °F) Publication 2080-SG001D-EN-P - December 2013 Micro800 Programmable Controller Family Selection Guide 37 Input Specifications Attribute Off-state voltage, max Off-state current, max On-state current, min On-state current, nom On-state current, max Nominal impedance IEC input compatibility Inrush current, max Input frequency, max 2080-LC50-48AWB 120V AC Input 20V AC 1.5 mA 5 mA @ 79V AC 12 mA @ 120V AC 16 mA @ 132V AC 12 k @ 50 Hz 10 k @ 60 Hz Type 3 250 mA @ 120V AC 63 Hz 2080-LC50-48QWB / 2080-LC50-48QVB / 2080-LC50-48QBB High-Speed DC Input (Inputs 0...11) Standard DC Input (Inputs 12 and higher) 5V DC 1.5 mA 5.0 mA @ 16.8V DC 1.8 mA @ 10V DC 7.6 mA @ 24V DC 6.15 mA @ 24V DC 12.0 mA @ 30V DC 3 k 3.74 k -- -- Output Specifications Attribute 2080-LC50-48AWB / 2080-LC50-48QWB 2080-LC50-48QVB / 2080-LC50-48QBB Relay Output Hi-Speed Output (Outputs 0 through 3) Standard Output (Outputs 4 and higher) Number of outputs 20 4 16 Output voltage, min 5V DC, 5V AC 10.8V DC 10V DC Output voltage, max 125V DC, 265V AC 26.4V DC 26.4V DC Load current, min 10 mA Load current, max 2.0 A 100 mA (high-speed operation) 1.0 A @ 30 °C 1.0 A @ 30 °C 0.3 A @ 65 °C (standard operation) 0.3 A @ 65 °C (standard operation) Surge current, per point See Relay Contacts Ratings on page 33 4.0 A for 10 ms every 1 s @ 30 °C; every 2 s @ 65 °C(1) Current, per common, max 5 A -- -- Turn on time/ Turn off time, max 10 ms 2.5 s 0.1 ms 1 ms (1) Applies for general purpose operation only. Does not apply for high-speed operation. Relay Contacts Ratings Maximum Volts 120V AC 240V AC 24V DC 125V DC Amperes Make 15 A 7.5 A 1.0 A 0.22 A Break 1.5 A 0.75 A Amperes Continuous 2.0 A 1.0 A Volt-Amperes Make Break 1800V A 180V A 28V A For relay life chart, see the Specifications section of the Micro830 and Micro850 User Manual, publication 2080-UM002. Publication 2080-SG001D-EN-P - December 2013 38 Micro800 Programmable Controller Family Selection Guide Environmental Specifications Attribute Value Temperature, operating IEC 60068-2-1 (Test Ad, Operating Cold), IEC 60068-2-2 (Test Bd, Operating Dry Heat), IEC 60068-2-14 (Test Nb, Operating Thermal Shock): -20...65 °C (-4...149 °F) Temperature, surrounding air, max 65 °C (149 °F) Temperature, non-operating IEC 60068-2-1 (Test Ab, Unpackaged Nonoperating Cold), IEC 60068-2-2 (Test Bb, Unpackaged Nonoperating Dry Heat), IEC 60068-2-14 (Test Na, Unpackaged Nonoperating Thermal Shock): -40...85 °C (-40...185 °F) Relative humidity IEC 60068-2-30 (Test Db, Unpackaged Damp Heat): 5...95% non-condensing Vibration IEC 60068-2-6 (Test Fc, Operating): 2 g @ 10...500 Hz Shock, operating IEC 60068-2-27 (Test Ea, Unpackaged Shock): 25 g Shock, non-operating IEC 60068-2-27 (Test Ea, Unpackaged Shock): DIN mount: 25 g PANEL mount: 35 g Emissions CISPR 11 Group 1, Class A ESD immunity IEC 61000-4-2: 4 kV contact discharges 8 kV air discharges Radiated RF immunity IEC 61000-4-3: 10V/m with 1 kHz sine-wave 80% AM from 80...2000 MHz 10V/m with 200 Hz 50% Pulse 100% AM @ 900 MHz 10V/m with 200 Hz 50% Pulse 100% AM @ 1890 MHz 10V/m with 1 kHz sine-wave 80% AM from 2000...2700 MHz EFT/B immunity IEC 61000-4-4: ±2 kV @ 5 kHz on power ports ±2 kV @5 kHz on signal ports ±1 kV @ 5 kHz on communication ports Surge transient immunity IEC 61000-4-5: ±1 kV line-line(DM) and ±2 kV line-earth(CM) on power ports ±1 kV line-line(DM) and ±2 kV line-earth(CM) on signal ports ±1 kV line-earth(CM) on communication ports Conducted RF immunity IEC 61000-4-6: 10V rms with 1 kHz sine-wave 80% AM from 150 kHz...80 MHz Publication 2080-SG001D-EN-P - December 2013 Micro800 Programmable Controller Family Selection Guide 39 Certifications Certification (when product is marked)(1) c-UL-us Value UL Listed Industrial Control Equipment, certified for US and Canada. See UL File E322657. UL Listed for Class I, Division 2 Group A,B,C,D Hazardous Locations, certified for U.S. and Canada. See UL File E334470. CE European Union 2004/108/EC EMC Directive, compliant with: EN 61326-1; Meas./Control/Lab., Industrial Requirements EN 61000-6-2; Industrial Immunity EN 61000-6-4; Industrial Emissions EN 61131-2; Programmable Controllers (Clause 8, Zone A & B) European Union 2006/95/EC LVD, compliant with: EN 61131-2; Programmable Controllers (Clause 11) C-Tick Australian Radiocommunications Act, compliant with: AS/NZS CISPR 11; Industrial Emissions EtherNet/IP ODVA conformance tested to EtherNet/IP specifications. KC Korean Registration of Broadcasting and Communications Equipment, compliant with: Article 58-2 of Radio Waves Act, Clause 3. (1) See the Product Certification link at http://www.rockwellautomation.com/products/certification for Declaration of Conformity, Certificates, and other certification details. Publication 2080-SG001D-EN-P - December 2013 40 Micro800 Programmable Controller Family Selection Guide Notes: Publication 2080-SG001D-EN-P - December 2013 Select Micro850 Expansion I/O The 2085 I/O expansion modules provide superior functionality in a small-sized low-cost package. A variety of digital and analog modules complement and extend the capabilities of Micro850 controllers by maximizing the flexibility of I/O count and type. Micro850 expansion I/O modules include high density discrete and analog I/O modules, including a high accuracy RTD and Thermocouple module. There are available solid state output modules which are recommended to reduce switching noise and for applications which require more switching cycles, than relays. Triac outputs are available for AC loads. Sink and source transistor outputs are available for DC loads. The following section provides the list of available Micro850 expansion I/O modules and their specifications. Micro850 Expansion I/O Modules Catalog Number 2085-IA8 2085-IM8 2085-OA8 2085-IQ16 2085-IQ32T 2085-OV16 2085-OB16 2085-OW8 2085-OW16 Type Discrete Discrete Discrete Discrete Discrete Discrete Discrete Discrete Discrete Description 8-point, 120V AC input 8-point, 240V AC input 8-point, 120/240V AC Triac Output 16-point, 12/24V DC Sink/Source Input 32-point, 12/24V DC Sink/Source Input 16-point, 12/24V DC Sink Transistor Output 16-point, 12/24V DC Source Transistor Output 8-point, AC/DC Relay Output 16-point, AC/DC Relay Output 41Publication 2080-SG001D-EN-P - December 2013 42 Micro800 Programmable Controller Family Selection Guide Micro850 Expansion I/O Modules Catalog Number Type Description 2085-IF4 Analog 4-channel, 14-bit isolated(2) voltage/current input 2085-IF8 Analog 8-channel, 14-bit isolated(2) voltage/current input 2085-OF4 Analog 4-channel, 12-bit isolated(2) voltage/current output 2085-IRT4 Specialty 4-channel, 16-bit RTD and TC isolated(2) input module 2085-ECR(1) Terminator 2085 bus terminator (1) The 2085-ECR bus terminator should always be the last module on the system, if any expansion I/O module is attached to the system. (2) Refers to isolation from field side wiring to controller, not channel-to-channel isolation. Discrete Expansion I/O 2085-IQ16 and 2085-IQ32T DC Sink/Source Input Modules(1) Attribute 2085-IQ16 2085-IQ32T Number of inputs 16 sink/source 32 sink/source Dimensions, HxWxD 44.5 x 90 x 87 mm (1.75 x 3.54 x 3.42 in.) Shipping weight, approx. 220 g (7.76 oz) Bus current draw, max Wire size Wiring category(2) 170 mA @ 5V DC 190 mA @ 5V DC 0.25... 2.5 mm2 (22...14 AWG) solid or stranded copper wire rated @ 75 °C (167 °F ), or greater, 1.2 mm (3/64 in.) insulation max 2 on signal ports Terminal screw torque, 0.5...0.6 Nm max (4.4...5.3 lb-in.)(3) Input circuit type 24V AC/DC sink/source Power dissipation, total 4.5 W 7 W Power supply 24V DC Status indicators 16 yellow indicators 32 yellow indicators Isolation voltage 50V (continuous), Reinforced Insulation Type, channel to system Type tested @ 720V DC for 60 s Enclosure type rating Meets IP20 North American temp T4 code Operating voltage range 10...30V DC, Class 2 21.6...26.4V AC, Class 2 See Derating Curve for 2085-IQ16 and Derating Curve for 2085-IQ32T on page 43 Off-state voltage, max 5V DC Publication 2080-SG001D-EN-P - December 2013 Micro800 Programmable Controller Family Selection Guide 43 2085-IQ16 and 2085-IQ32T DC Sink/Source Input Modules(1) Attribute 2085-IQ16 2085-IQ32T Off-state current, max 1.5 mA 1.2 mA On-state current, min 1.8 mA @ 10V DC On-state current, nom 6.0 mA @ 24V DC 5.2 mA @ 24V DC On-state current, max 8.0 mA @ 30V DC 7.0 mA @ 30V DC Input impedance, max 3.9 k 4.6 k IEC input compatibility Type 3 Type 1 (1) Meets IEC Type 1 24V DC Input Specifications. (2) Use this Conductor Category information for planning conductor routing. Refer to Industrial Automation Wiring and Grounding Guidelines, publication 1770-4.1. (3) RTB hold down screws should be tightened by hand. They should not be tightened using a power tool. Derating Curve for 2085-IQ16 Input voltage (V) 30 26.4 30°C 65°C Temp 45302 Derating Curve for 2085-IQ32T Input voltage (V) 30 26.4 30°C 24 65°C 18 24 Number of inputs 32 45301 2085-OV16 Sink and 2085-OB16 Source DC Output Module Attribute Number of outputs Operating voltage range On-state voltage, min On-state voltage, nom On-state voltage, max On-state current, max Dimensions, HxWxD 2085-OV16 16 sinking 10...30V DC 10V DC 24V DC 30V DC 0.5 A @ 30V DC, per output 8 A, per module 44.5 x 90 x 87 mm (1.75 x 3.54 x 3.42 in.) 2085-OB16 16 sourcing Publication 2080-SG001D-EN-P - December 2013 44 Micro800 Programmable Controller Family Selection Guide 2085-OV16 Sink and 2085-OB16 Source DC Output Module Attribute 2085-OV16 2085-OB16 Shipping weight, approx. 220 g (7.76 oz) Bus current draw, max Wire size Wiring category(1) 200 mA @ 5V DC 0.25... 2.5 mm2 (22...14 AWG) solid or stranded copper wire rated @ 75 °C (167 °F ), or greater, 1.2 mm (3/64 in.) insulation max 2 on signal ports Terminal screw torque, max 0.5...0.6 Nm (4.4...5.3 lb-in.)(2) Output circuit type 24V DC sink 24V DC source Power dissipation, total 5 W Power supply 24V DC, Class 2 Status indicators 16 Yellow channel indicators Isolation voltage 50V (continuous), Reinforced Insulation Type, channel to system Type tested @ 720V AC for 60 s Enclosure type rating Meets IP20 North American temp code T4 (1) Use this Conductor Category information for planning conductor routing. Refer to Industrial Automation Wiring and Grounding Guidelines, publication 1770-4.1. (2) RTB hold down screws should be tightened by hand. They should not be tightened using a power tool. 2085-IA8, 2085-IM8, 2085-OA8 AC Input/Output Modules Attribute 2085-IA8 2085-IM8 2085-OA8 Number of inputs 8 Dimensions, HxWxD 28 x 90 x 87 mm (1.10 x 3.54 x 3.42 in.) Shipping weight, approx. 140 g (4.93 oz) Bus current draw, max Wire size 5V DC, 150 mA 5V DC, 180 mA 0.25... 2.5 mm2 (22...14 AWG) solid or stranded copper wire rated @ 75 °C (167 °F ), or greater, 1.2 mm (3/64 in.) insulation max Insulation stripping length 10 mm (0.39 in.) Wiring category(1) 2 on signal ports Wire type Copper Terminal screw torque, max 0.5...0.6 Nm (4.4...5.3 lb-in.)(2) Input/output circuit type 120V AC input 240V AC input 120V/240V AC output Power supply 120V AC 240V AC 120V/240V AC Power dissipation, total 2.36 W 2.34 W 5.19 W Enclosure type rating Meets IP20 Publication 2080-SG001D-EN-P - December 2013 Micro800 Programmable Controller Family Selection Guide 45 2085-IA8, 2085-IM8, 2085-OA8 AC Input/Output Modules Attribute 2085-IA8 2085-IM8 2085-OA8 Status indicators 8 yellow indicators Isolation voltage 150V (continuous), Reinforced Insulation Type, channel to system Type tested @ 1950V DC for 60 s 240V (continuous), Reinforced Insulation Type, channel to system Type tested @ 3250V DC for 60 s North American temp code T4 (1) Use this Conductor Category information for planning conductor routing. Refer to Industrial Automation Wiring and Grounding Guidelines, publication 1770-4.1. (2) RTB hold down screws should be tightened by hand. They should not be tightened using a power tool. Input Specifications 2005-IA8 and 2085-IM8 Attribute Number of Inputs Voltage category Operating voltage range Off-state voltage, max Off-state current, max On-state current, min On-state current, max Input impedance, max Inrush current, max Input filter time Off to On On to Off IEC type compliance 2085-IA8 8 120V AC 74...120V AC 20V AC 2.5 mA 5.0 mA @ 74V AC 12.5 mA @ 120V AC 22.2 k 450 mA < 20 ms Type 3 2085-IM8 240V AC 159...240V AC 40V AC 4.0 mA @ 159V AC 7.0 mA @ 240V AC Output Specifications 2085-OA8 Attribute Number of Inputs Voltage category Operating voltage range Output voltage, min Output voltage, max Off-state current, max On-state current, min On-state current, max On-state current, per module, max Off-state voltage drop, max Fusing 2085-OA8 8 120V/230V AC 120...240V AC 85V AC 240V AC 2.5 mA 10 mA per output 0.5 A per output 4 A 1.5V AC @ 0.5 A 2.5V AC @10 mA Not protected. A suitable rating fuse is recommended to protect outputs. Publication 2080-SG001D-EN-P - December 2013 46 Micro800 Programmable Controller Family Selection Guide Output Specifications 2085-OA8 Attribute Output signal delay Off to On On to Off Surge current, max 2085-OA8 9.3 ms for 60 Hz, 11 ms for 50 Hz 9.3 ms for 60 Hz, 11 ms for 50 Hz 5 A 2085-OW8 and 2085-OW16 Relay Output Module Attribute 2085-OW8 2085-OW16 Number of outputs 8, relay 16, relay Dimensions, HxWxD 28 x 90 x 87 mm (1.10 x 3.54 x 3.42 in.) 44.5 x 90 x 87 mm (1.75 x 3.54 x 3.42 in.) Shipping weight, approx. Wire size 140 g (4.93 oz) 220 g (7.76 oz) 0.25... 2.5 mm2 (22...14 AWG) solid or stranded copper wire rated @ 75 °C (167 °F ), or greater, 1.2 mm (3/64 in.) insulation max Insulation strip length 10 mm (0.39 in.) Wiring category(1) 2 on signal ports Wire type Copper Terminal screw torque. max 0.5...0.6 Nm (4.4...5.3 lb-in.)(2) Bus current draw, max 5V DC, 120 mA 24V DC, 50 mA 5V DC, 160 mA 24V DC, 100 mA Load current, max 2 A Power dissipation, total 2.72 W 5.14 W Relay contact, (0.35 power factor) Max Volts 120V AC 240V AC 24V DC 125V DC Amperes Make Break 15 A 1.5 A 7.5 A 0.75 A 1.0 A 0.22 A Amperes Volt Amperes Continuous Make Break 2.0 A 1800V A 180V A 1.0 A 28V A Minimum load, per point 10 mA per point Off-state leakage, max 1.5 mA Status indicators 8 yellow indicators 16 yellow indicators Isolation voltage 240V (continuous), Reinforced Insulation Type, channel to system Type tested @ 3250V DC for 60 s Pilot duty rating C300, R150 Enclosure type rating Meets IP20 North American temp T4 code (1) Use this Conductor Category information for planning conductor routing. Refer to Industrial Automation Wiring and Grounding Guidelines, publication 1770-4.1. (2) RTB hold down screws should be tightened by hand. They should not be tightened using a power tool. Publication 2080-SG001D-EN-P - December 2013 Micro800 Programmable Controller Family Selection Guide 47 Analog Expansion I/O 2085-IF4, 2085-IF8, 2085-OF4 Analog Input and Output Modules Attribute 2085-IF4 2085-OF4 2085-IF8 Number of I/O 4 8 Dimensions, HxWxD 28 x 90 x 87 mm (1.1 x 3.54 x 3.42 in.) 44.5 x 90 x 87 mm (1.75 x 3.54 x 3.42 in.) Shipping weight, approx. 140 g (4.93 oz) 220 g (7.76 oz) Bus current draw, max Wire size Wiring category(1) 5V DC, 100 mA 24V DC, 50 mA 5V DC, 160 mA 24V DC, 120 mA 5V DC, 110 mA 24V DC, 50 mA 0.25... 2.5 mm2 (22...14 AWG) solid or stranded copper wire rated @ 75 °C (167 °F ), or greater, 1.2 mm (3/64 in.) insulation max 2 on signal ports Wire type Shielded Terminal screw torque 0.5...0.6 Nm (4.4...5.3 lb-in.)(2) Power dissipation, total 1.7 W 3.7 W 1.75 W Enclosure type rating Meets IP20 Status indicators 1 green health indicator 1 green health indicator 1 green health indicator 8 red error indicators Isolation voltage 50V (continuous), Reinforced Insulation Type, channel to system and channel to channel. Type tested @ 720V DC for 60 s North American temp T4 code (1) Use this Conductor Category information for planning conductor routing. Refer to Industrial Automation Wiring and Grounding Guidelines, publication 1770-4.1. (2) RTB hold down screws should be tightened by hand. They should not be tightened using a power tool. Input Specifications 2085-IF4 and 2085-IF8 Attribute Number of inputs Resolution Voltage Current Data format Conversion type Update rate Step response time up to 63% Input current terminal, user configurable Input voltage terminal, user configurable 2085-IF4 2085-IF8 4 8 14 bits (13 bits plus sign bit) 1.28 mV/cnt unipolar; 1.28 mV/cnt bipolar 1.28 A/cnt Left justified, 16 bit 2s complement SAR < 2 ms per enabled channel without 50 Hz/60 Hz rejection, < 8 ms for all channel 8 ms with 50 Hz/60 Hz rejection 4...60 ms without 50Hz/60 Hz rejection depends on number of enabled channel and filter setting 600 ms with 50 Hz/60 Hz rejection 4...20 mA (default) 0...20 mA ±10V 0...10V Publication 2080-SG001D-EN-P - December 2013 48 Micro800 Programmable Controller Family Selection Guide Input Specifications 2085-IF4 and 2085-IF8 Attribute Input impedance Absolute accuracy Accuracy drift with temp Calibration required Overload, max. Channel diagnostics 2085-IF4 2085-IF8 Voltage terminal >1 M Current terminal <100 ±0.10% Full Scale @ 25 ° C Voltage terminal 0.00428 % Full Scale/° C Current terminal 0.00407 % Full Scale/° C Factory calibrated. No customer calibration supported. 30V continuous or 32 mA continuous, one channel at a time. Over and under range or open circuit condition by bit reporting Output Specifications 2085-OF4 Attribute 2085-OF4 Number of outputs 4 Resolution Voltage Current 12 bits unipolar; 11 bits plus sign bipolar 2.56 mV/cnt unipolar; 5.13 mV/cnt bipolar 5.13 A/cnt Data format Left justified, 16 bit 2s complement Step response time up to 63% 2 ms Conversion rate, max 2 ms per channel Output current terminal, user configurable 0 mA output until module is configured 4...20 mA (default) 0...20 mA Output voltage terminal, user configurable ±10V 0...10V Current load on voltage output, max 3 mA Absolute accuracy Voltage terminal Current terminal 0.133 % Full Scale @ 25 ° C or better 0.425 % Full Scale @ 25 ° C or better Accuracy drift with temp Voltage terminal 0.0045 % Full Scale/° C Current terminal 0.0069 % Full Scale/° C Resistive load on mA output 15...500 ohm @ 24V DC Specialty Expansion I/O 2085-IRT4 Temperature Input Module Attribute Number of inputs Dimensions, HxWxD Shipping weight, approx. Bus current draw, max 2085-IRT4 4 44.5 x 90 x 87 mm (1.75 x 3.54 x 3.42 in.) 220 g (7.76 oz) 5V DC, 160 mA 24V DC, 50 mA Publication 2080-SG001D-EN-P - December 2013 Micro800 Programmable Controller Family Selection Guide 49 2085-IRT4 Temperature Input Module Attribute Wire size Wiring category(1) 2085-IRT4 0.25... 2.5 mm2 (22...14 AWG) solid or stranded copper wire rated @ 75 °C (167 °F ), or greater, 1.2 mm (3/64 in.) insulation max 2 on signal ports Terminal screw torque 0.5...0.6 Nm (4.4...5.3 lb-in.)(2) Input type Thermocouple type: B, C, E, J, K, TXK/XK (L), N, R, S, T RTD type: 100 Pt = 0.00385 Euro 200 Pt = 0.00385 Euro 100 Pt = 0.003916 U.S 200 Pt = 0.003916 U.S. 100 Nickel 618 200 Nickel 618 120 Nickel 672 10 Copper 427 mV range: 0...100 mV Ohm input: 0...500 Resolution 16 bits Channel update time, typical 12...500 ms per enabled channel Input impedance > 10 M Accuracy ±0.5...±3.0 °C accuracy for Thermocouple inputs ±0.2...±0.6 °C accuracy for RTD inputs Power dissipation, total 2 W Enclosure type rating Meets IP20 Status indicators 1 green health indicator Isolation voltage 50V (continuous), Reinforced Insulation Type, channel to system. Type tested @ 720V DC for 60 s North American temp code T4 (1) Use this Conductor Category information for planning conductor routing. Refer to Industrial Automation Wiring and Grounding Guidelines, publication 1770-4.1. (2) RTB hold down screws should be tightened by hand. They should not be tightened using a power tool. Environment Specifications Environment Specifications for All Micro850 Expansion I/O Modules Attribute Value Temperature, operating IEC60068-2-1 (Test Ad, Operating Cold), IEC60068-2-2, (Test Bd, Operating Dry Heat), IEC 60068-2-14 (Test Nb, Operating Thermal Shock): -20...65 °C (-4...149 °F) Temperature, nonoperating IEC 60068-2-1 (Test Ab, Unpackaged Nonoperating Cold), IEC 60068-2-2 (Test Bb, Unpackaged Nonoperating Dry Heat), IEC 60068-2-14 (Test Na, Unpackaged Nonoperating Thermal Shock): -40...85 °C (-40...185 °F) Temperature, surrounding air, max. 65 °C (149 °F) Relative humidity IEC 60068-2-30 (Test Db, Unpackaged Damp Heat): 5...95% noncondensing Vibration IEC 60068-2-6 (Test Fc, Operating): 2 g @ 10...500 Hz Publication 2080-SG001D-EN-P - December 2013 50 Micro800 Programmable Controller Family Selection Guide Environment Specifications for All Micro850 Expansion I/O Modules Attribute Shock, operating Shock, nonoperating Emissions ESD Immunity Radiated RF Immunity EFT/B Immunity Surge Transient Immunity Conducted RF Immunity Value IEC 60068-2-27 (Test Ea, Unpackaged Shock): 25 g IEC 60068-2-27 (Test Ea, Unpackaged Shock): 25 g for DIN Rail Mounting 35 g for Panel Mounting CISPR 11: Group 1, Class A IEC 61000-4-2: 6 kV contact discharges 8 kV air discharges IEC 61000-4-3: 10V/m with 1 kHz sine-wave 80% AM from 80...2000 MHz 10V/m with 200 Hz 50% Pulse 100% AM @ 900 MHz 10V/m with 200 Hz 50% Pulse 100% AM @ 1890 MHz 10V/m with 1 kHz sine-wave 80% AM from 2000...2700 MHz IEC 61000-4-4: ±2 kV @ 5 kHz on signal ports IEC 61000-4-5: ±1 kV line-line(DM) and ±2 kV line-earth(CM) on power ports ±2 kV line-earth(CM) on shielded ports IEC 61000-4-6: 10V rms with 1 kHz sine-wave 80% AM from 150 kHz...80 MHz Certifications All Micro800 Expansion I/O Modules Certification (when product is marked)(1) c-UL-us Value UL Listed Industrial Control Equipment, certified for US and Canada. See UL File E322657. UL Listed for Class I, Division 2 Group A,B,C,D Hazardous Locations, certified for U.S. and Canada. See UL File E334470 CE European Union 2004/108/EC EMC Directive, compliant with: EN 61326-1; Meas./Control/Lab., Industrial Requirements EN 61000-6-2; Industrial Immunity EN 61000-6-4; Industrial Emissions EN 61131-2; Programmable Controllers (Clause 8, Zone A & B) C-Tick Australian Radiocommunications Act, compliant with: AS/NZS CISPR 11; Industrial Emissions KC Korean Registration of Broadcasting and Communications Equipment, compliant with: Article 58-2 of Radio Waves Act, Clause 3 (1) See the Product Certification link athttp://www.rockwellautomation.com/products/certification/ for Declaration of Conformity, Certificates, and other certification details. Publication 2080-SG001D-EN-P - December 2013 Select Micro800 Plug-in Modules and Accessories Micro800 plug-in modules extend the functionality of embedded I/O without increasing the footprint of the controller. It improves performance by adding additional processing power or capabilities and adds additional communication functionality. Micro820, Micro830 and Micro850 controllers support plug-in modules. Micro800 accessories consist of a Remote LCD (compatible with Micro820 only), an LCD with keypad (compatible with Micro810 only), a USB adapter (compatible with Micro810 only), and an expansion power supply. 51Publication 2080-SG001D-EN-P - December 2013 52 Micro800 Programmable Controller Family Selection Guide Micro800 Plug-in Modules and Accessories Features and Compatibility Plug-in / Accessory Supported by Supported by Supported by Feature Micro810 Micro820 Micro830/Micro850 1.5" LCD and Keypad 2080-LCD Yes No No · backup module for Micro810 controllers · configure Smart Relay Function Blocks Micro810 USB Adapter 2080-USBADAPTER Yes No No USB programming access External Power Supply 2080-PS120-240VAC Yes Yes Yes optional controller power supply RS232/485 Isolated Serial Port No 2080-SERIALISOL Yes Yes · adds additional serial communications with Modbus RTU and ASCII protocols · isolated for increased noise immunity Digital Input, Output, Relay, and No Yes Yes Combination Modules 2080-IQ4, 2080-IQ4OB4, 2080-IQ4OV4, 2080-OB4, 2080-OV4, 2080-OW4I · 4-channel inputs/outputs or combination modules · configurable as voltage and current inputs · sink or source output · 4-channel relay outputs High Speed Counter 2080-MOT-HSC No Yes Yes · Up to a minimum of 250 KHz differential line driver for improved noise immunity and additional dedicated I/O · One Quadrature (ABZ) differential inputs alternately configurable for pulse internal, pulse with external direction, A-up and B-down input configurations, and quadrature mode · User-configurable minimum and maximum values, preset, and Z operation DeviceNet Scanner 2080-DNET20 No Yes Yes · Scanner mode scan devices such as CompactBlockTM LDX, PowerFlex® drives, overloads and sensors Remote LCD 2080-REMLCD No Yes No · Operator interface for configuring such settings as IP address on Micro820 controller · With RS232 and USB ports Non-isolated Unipolar Analog No Input/Output 2080-IF2, 2080-IF4, 2080-OF2 Yes Yes · adds up to 20 embedded analog I/O with 12-bit resolution (with 48-point controllers) · 2 channels for 2080-IF2, 2080-OF2 · 4 channels for 2080-IF4 Non-isolated Thermocouple No 2080-TC2 Non-isolated RTD No 2080-RTD2 Yes Yes Yes Yes · for temperature control, when used with PID · 2 channels for 2080-TC2 and 2080-RTD2 Memory Module with RTC 2080-MEMBAK-RTC No No Yes · backup project data and application code · high accuracy real-time clock 6-Channel Trim Potentiometer No Analog Input 2080-TRIMPOT6 Yes Yes adds six analog presets for speed, position and temperature control Publication 2080-SG001D-EN-P - December 2013 Micro800 Programmable Controller Family Selection Guide 53 Micro800 Plug-In Modules Digital Input, Output, Relay, and Combination Plug-Ins Specifications (2080-IQ4, 2080-IQ4OB4, 2080-IQ4OV4, 2080-OB4, 2080-OV4) Catalog 2080-IQ4 2080-IQ4OB4 2080-IQ4OV4 2080-OB4 2080-OV4 Input / Output On-state voltage On-state current 4 inputs DC 9.0V DC, min 30V DC, max AC 10.25V AC (rms), min 30V AC (rms), max DC 2.0 mA @ 9V DC, min 3.0 mA @ 24V DC, nom 5.0 mA, max AC 2.0 mA @ 9V AC (rms), min 5.0 mA, max 4 channel inputs/source outputs combination 4 channel inputs/sink outputs combination DC Input 9.0V DC, min 30V DC, max AC Input 10.25V AC (rms), min 30V AC (rms), max Output 10V DC, min 24V DC, nom 30V DC, max DC Input 2.0 mA @ 9V DC, min 3.0 mA @ 24V DC, nom 5.0 mA, max AC Input 2.0 mA @ 9V AC (rms), min 5.0 mA, max Output 5.0 mA @ 10V DC, min 0.5 A max, steady state 2 A surge, 2 s min 4 source outputs 4 sink outputs 10V DC, min 24V DC, nom 30V DC, max 5.0 mA @ 10V DC, min 0.5 A max, steady state 2 A surge, 2 s min Publication 2080-SG001D-EN-P - December 2013 54 Micro800 Programmable Controller Family Selection Guide Specifications (2080-IQ4, 2080-IQ4OB4, 2080-IQ4OV4, 2080-OB4, 2080-OV4) Catalog Off-state voltage 2080-IQ4 2080-IQ4OB4 2080-IQ4OV4 2080-OB4, 2080-OV4 DC 5V DC, max AC 3.5V AC (rms) Off-state current DC 1.5 mA, max Power supply voltage 10.8V DC, min 30V DC, max Mounting torque 0.2 Nm (1.48 lb-in.) Status indicators 4 yellow 8 yellow 4 yellow North American temp code T4 Catalog 2080-IQ4 2080-IQ4OB4 2080-IQ4OV4 2080-OB4 2080-OV4 Terminal base screw torque 0.22...0.25 Nm (1.95...2.21 lb-in.) using a 2.5 mm (0.10 in.) flat-blade screwdriver Isolation voltage 50V (continuous), Basic Insulation Type, Inputs to Backplane Type tested for 60 s @ 720V DC, Inputs to Backplane 50V (continuous), Basic Insulation Type, Inputs to Outputs, I/Os to Backplane Type tested for 60 s @ 720V DC, I/Os to Backplane Wire size 0.2... 2.5 mm2 (24...12 AWG) solid or stranded copper wire rated @ 90 °C (194 °F), or greater, insulation max Catalog 2080-IQ4 2080-IQ4OB4 2080-IQ4OV4 2080-OB4 2080-OV4 Operating temperature -20...65 °C (-4...149 °F) Non-operating temperature -40...85 °C (-40...185 °F) Surrounding air, max 65 °C (149 °F) Relative humidity Vibration 5...95% 2 g @ 10...500 Hz noncondensing Shock, operating 25 g Shock, non-operating 25 g Specifications (2080-OW4I) Catalog 2080-OW4I Input/Output 4-channel relay output Inrush current Backplan e power <120 mA @ 3.3V 3.3 VDC, <120 mA @ 24V 38 mA Output current, Output current, resistive inductive Output power, resistive, max 2 A @ 5...30V DC 0.5 A @ 48V DC 0.22 A @ 125V DC 2 A @ 125V AC 2 A @ 240V AC 1.0 A steady state @ 5...28V DC 0.93 A steady state @ 30V DC 0.5 A steady state @ 48V DC 0.22 A steady state @ 125V DC 2.0 A steady state, 15 A make @ 125V AC, PF cos = 0.4 2.0 A steady state, 7.5 A make @ 240V AC, PF cos = 0.4 250V A for 125V AC resistive loads 480V A for 240V AC resistive loads 60V A for 30V DC resistive loads 24V A for 48V DC resistive loads 27.5V A for 125V DC resistive loads Publication 2080-SG001D-EN-P - December 2013 Micro800 Programmable Controller Family Selection Guide 55 Catalog Output power, inductive break, max Pilot duty rating 2080-OW4I 180 VA for 125V AC inductive loads 180 VA for 240V AC inductive loads 28 VA for 28.8V DC inductive loads 28 VA for 48V DC inductive loads 28 VA for 125V DC inductive loads C300, R150 Minimum load, per point 10 mA Initial contact resistance of relay, max 30 m Output delay time, max 10 ms ON or OFF Catalog 2080-OW4I Relay contact, (0.35 power factor) Volts, max Amperes Make Break 120V AC 15 A 1.5 A 240V AC 7.5 A 0.75 A 24V DC 1.0 A 125V DC 0.22 A Amperes Continuous 2.0 A 1.0 A Volt-Amperes Make 1800V A Break 180V A 28V A Catalog 2080-OW4I Operating temperature -20...65 °C (-4...149 °F) Non-operating temperature -40...85 °C (-40...185 °F) Surrounding air, max 65 °C (149 °F) Relative humidity Vibration 5...95% 2 g @ 10...500 Hz noncondensing Shock, operating 10 g Shock, non-operating DIN rail mounting: 25 g Panel mounting: 35 g Analog Input and Output Plug-ins Specifications (2080-IF2, 2080-IF4, 2080-OF2) Catalog 2080-IF2 2080-IF4 2080-OF2 Number of inputs/ outputs Voltage Current Power Input impedance Voltage range range consumption resistive load 2 inputs, unipolar non-isolated 4 inputs, unipolar non-isolated 0...10V 0...20 mA <60 mA @ 3.3V >100 k for voltage mode 250 for current mode 2 outputs, unipolar non-isolated <60 mA @ 24V 1 k, min Catalog 2080-IF2 2080-IF4 2080-OF2 Current Mounting Terminal screw Wire size resistive torque torque load Operating temp. 500 0.2 Nm (1.48 lb-in.) 0.22...0.25 Nm (1.95...2.21 lb-in.) using a 2.5 mm (0.10 in.) flat-blade screwdriver Solid: 0.14 mm2 (26 AWG), min 1.5 mm2 (16 AWG), max Stranded: 0.14 mm2 (26 AWG), min 1.0 mm2 (18 AWG), max rated @ 90 °C (194 °F ) insulation max -20...65 °C (-4...149 °F) Non-operating temp. -40...85 °C (-40...185 °F) Surrounding North air, max American temp code 65 °C (149 °F) T4 Publication 2080-SG001D-EN-P - December 2013 56 Micro800 Programmable Controller Family Selection Guide Thermocouple and RTD (2080-TC2, 2080-RTD2) Specifications (2080-RTD2, 2080-TC2) Catalog Type 2080-RTD2 2-channel non-isolated RTD 2080-TC2 2-channel non-isolated Thermocouple Common mode rejection ratio 100 dB @ 50/60Hz Normal mode rejection ratio 70 dB @ 50/60 Hz Catalog 2080-RTD2 Type Common mode rejection ratio 2-channel 100 dB @ non-isolated RTD 50/60Hz 2080-TC2 2-channel non-isolated Thermocouple Normal mode RTD types rejection ratio supported Thermocouple types supported 70 dB @ 50/60 Hz 100 Platinum 385, 200 Platinum 385, 500 Platinum 385, 1000 Platinum 385, 100 Platinum 392, 200 Platinum 392, 500 Platinum 392, 1000 Platinum 392, 10 Copper 427, 120 Nickel 672, 604 Nickel-Iron 518 J, K, N, T, E, R, S, B Terminal screw torque 0.22...0.25 Nm (1.95...2.21 lb-in.) using a 2.5 mm (0.10 in.) flat-blade screwdriver Catalog Wire size 2080-RTD2 2080-TC2 Solid: 0.14 mm2 (26 AWG), min 1.5 mm2 (16 AWG), max Stranded: 0.14 mm2 (26 AWG), min 1.0 mm2 (18 AWG), max rated @ 90 °C (194 °F ) insulation max Operating temperature -20...65 °C (-4...149 °F) Non-operating temperature -40...85 °C (-40...185 °F) Surrounding air, max 65 °C (149 °F) North American temp code T4 Trimpot Analog Input (2080-TRIMPOT6) Specifications (2080-TRIMPOT6) Numberof Mounting Operating Non-operating Surrounding inputs torque temperature temperature air, max 6-channel, Trimpot 0.2 Nm -20...65 °C -40...85 °C (1.48 lb-in.) (-4...149 °F) (-40...185 °F) 65 °C (149 °F) North American temp code T4 Publication 2080-SG001D-EN-P - December 2013 Micro800 Programmable Controller Family Selection Guide 57 Memory Backup and High Accuracy RTC Plug-In (2080-MEMBAK-RTC) Specifications (2080-MEMBAK-RTC) Mounting torque 0.2 Nm (1.48 lb-in) Terminal Operating screw torque temperature 0.22....0.25 Nm (1.95...2.21 lb-in.) using a 2.5 mm (0.10 in.) flat-blade screwdriver -20...65 °C (-4...149 °F) Non-operating temperature -40...85 °C (-40...185 °F) Surrounding North air, max American temp code 65 °C T4 (149 °F) RS232/485 Serial Port Plug-in (2080-SERIALISOL) Specifications (2080-SERIALISOL) Mounting Terminal screw torque torque 0.2 Nm (1.48 lb-in) 0.22...0.25 Nm (1.95...2.21 lb-in) using a 2.5 mm (0.10 in.) flat-blade screwdriver Wire size Solid: 0.14...1.5 mm2 (26...16 AWG) Stranded: 0.14...1.0 mm2 (26...18 AWG) rated @ 90 °C (194 °F ) insulation max Isolation voltage 500V AC Operating temperature -20...65 °C (-4...149 °F) Non-operating temperature -40...85 °C (-40...185 °F) Surrounding air, max 65 °C (149 °F) North American temp code T4 Publication 2080-SG001D-EN-P - December 2013 58 Micro800 Programmable Controller Family Selection Guide DeviceNet (2080-DNET20) Specifications (2080-DNET20) DeviceNet Communication Rate, max 125 Kbps 420 m (1378 ft.) 250 Kbps 200 m (656 ft.) 500 Kbps 75 m (246 ft.) DeviceNet current 24V DC, 300 mA Class 2 Wire size 0.25... 2.5 mm2 (22...14 AWG) solid or stranded copper wire rated @ 75 °C (167 °F ), or greater, 1.2 mm (3/64 in.) insulation max Network protocol I/O Slave Messaging: Poll Command Backplane power consumption 50 mA @ 24V DC Power dissipation 1.44 W Number of nodes, max 20 nodes for I/O operation High Speed Counter (2080-MOT-HSC) Specifications (2080-MOT-HSC) Input Frequency, max 250 kHz (50% duty) Wire size Solid: 0.14...1.5 mm2 (26...16 AWG) Stranded: 0.14...1.0 mm2 (26...18 AWG) rated @ 90 °C (194 °F ) insulation max Number of inputs 1 Quadrature (ABZ) differential input Input impedance Pulse width, min 3580 2 s All supply power and/or current ratings Isolation voltage Input/Output: 24V DC Input module: 50V (continuous), Basic Insulation Type, Inputs/Outputs to Backplane. Type tested for 60s @ 720V DC, Inputs/Outputs to Backplane Micro800 Accessories Micro810 LCD (2080-LCD) Operating temperature Temperature, surrounding air, max -20..55 °C (-4...131 °F) 55 °C (131 °F) Temperature, nonoperating -40...85 °C (-40...185 °F) North American temp code T5 Micro810 USB Adapter (2080-USBADAPTER) USB cable Temperature, Temperature, Temperature, connector type operating surrounding air, max non-operating USB Type A-B Male-Male -20...55 °C 55 °C (131 °F) (-4...131 °F) -40...85 °C (-40...185 °F) North American temp code T5 Publication 2080-SG001D-EN-P - December 2013 Micro800 Programmable Controller Family Selection Guide 59 External Power Supply (2080-PS120-240VAC) Attribute Value Dimensions, HxWxD 90 x 45 x 80 mm (3.55 x 1.78 x 3.15 in) Shipping weight Supply voltage range(1) 0.34 kg (0.75 lb) 100V...120V AC, 1A 200...240V AC, 0.5A Supply frequency 47...63 Hz Supply power 24V DC, 1.6 A Inrush current, max Power consumption(2) (Output power) 24 A @ 132V for 10 ms 40 A @ 263V for 10 ms 38.4 W @ 100V AC, 38.4 W @ 240V AC Power dissipation (Input power) 45.1 W @ 100V AC, 44.0W @ 240V AC Isolation voltage 250V (continuous), Primary to Secondary: Reinforced Insulation Type Type tested for 60s @ 2300V AC primary to secondary and 1480V AC primary to earth ground. Output ratings 24V DC, 1.6 A, 38.4 W max. (1) Any fluctuation in voltage source must be within 85V...264V. Do not connect the adapter to a power source that has fluctuations outside of this range. (2) When setting up a Micro800 system, verify that total power consumption of the controller, plug-in and expansion I/O does not exceed the output power capacity of the power supply used. Remote LCD (2080-REMLCD) Attribute Value Dimensions, HxWxD 97 x 130 x 35.5 mm (3.82 x 5.12 x 1.40 in.) Display type 192 x 64 pixel monochrome Display size 48 x 106.5 mm (1.89 x 4.19 in.) Backlight 25000 hrs @ 25 °C LED; tricolor backlight (RGB) Operator input Tactile keys (function keys, arrow keys, ESC and OK keys) Programming port USB to serial converter for programming the controller Input supply voltage 12V/24V DC (±10%) Input supply current, max 90 mA @ 12V and 60 mA @ 24V Power consumption, max 1.5 W Weight, approx. 405 g (0.89 lb) includes packaging weight Wire size Single-wire gauge: 0.14...1.5 mm2 (26...16 AWG) rated @ 90 °C (194 °F) Dual-wire gauge: 0.14...0.75 mm2 (26...18 AWG) rated @ 90 °C (194 °F) Wire type Wiring category(1) Copper 3 on power ports; 3 on communication port Enclosure type ratings Meets IP65 (when front panel mounted) North American temp code T4 (1) Use this conductor category information. Publication 2080-SG001D-EN-P - December 2013 60 Micro800 Programmable Controller Family Selection Guide For More Information Visit the Micro800 website at http://ab.rockwellautomation.com/Programmable-Controllers/Micro800 to learn more about Micro800 products and download Connected Component Workbench software and Micro800 firmware updates. If you would like a manual, you can: · download a free electronic version from the Internet: http://rockwellautomation.com/literature. · purchase a printed manual by contacting your local Allen-Bradley distributor or Rockwell Automation representative. You can also visit the following websites for additional technical information: · Sample Code Library http://samplecode.rockwellautomation.com/idc/groups/public/docume nts/webassets/sc_home_page.hcst · Technical Forums http://www.rockwellautomation.com/forums/ · Connected Component Accelerator Toolkit http://www.rockwellautomation.com/components/connected/ccat.html Additional Resources These documents contain additional information concerning related Rockwell Automation products. Resource Description Micro810 Programmable Controllers User Manual, publication 2080-UM001 xxxxx A more detailed description of how to install and use your Micro810 programmable controller. Micro820 Programmable Controllers User Manual, publication 2080-UM005 A more detailed description of how to install and use your Micro820 programmable controllers. Micro830 and Micro850 Programmable Controllers User Manual, publication 2080-UM002 xxxxxxx A more detailed description of how to install and use your Micro830 and Micro850 programmable controller. Micro800 Plug-in Modules User Manual, publication 2080-UM004 Description of features, installation, wiring, and specifications for the Micro800 plug-in modules. Micro800 Discrete and Analog Expansion I/O Description of features, installation, wiring, and Modules User Manual, publication specifications for the Micro800 expansion I/O 2080-UM003 modules and accessories. Industrial Automation Wiring and Grounding Provides general guidelines for installing a Rockwell Guidelines, publication Automation industrial system. 1770-4.1 Product Certifications website, Provides declarations of conformity, certificates, and http://www.rockwellautomation.com/produ other certification details. cts/certification/ Publication 2080-SG001D-EN-P - December 2013 Rockwell Automation Support Rockwell Automation provides technical information on the Web to assist you in using its products. At http://www.rockwellautomation.com/support/, you can find technical manuals, a knowledge base of FAQs, technical and application notes, sample code and links to software service packs, and a MySupport feature that you can customize to make the best use of these tools. For an additional level of technical phone support for installation, configuration, and troubleshooting, we offer TechConnect support programs. For more information, contact your local distributor or Rockwell Automation representative, or visit http://www.rockwellautomation.com/support/. Installation Assistance If you experience a problem within the first 24 hours of installation, review the information that is contained in this manual. You can contact Customer Support for initial help in getting your product up and running. United States or Canada Outside United States or Canada 1.440.646.3434 Use the Worldwide Locator at http://www.rockwellautomation.com/support/americas/phone_en.html, or contact your local Rockwell Automation representative. New Product Satisfaction Return Rockwell Automation tests all of its products to ensure that they are fully operational when shipped from the manufacturing facility. However, if your product is not functioning and needs to be returned, follow these procedures. United States Outside United States Contact your distributor. You must provide a Customer Support case number (call the phone number above to obtain one) to your distributor to complete the return process. Please contact your local Rockwell Automation representative for the return procedure. Documentation Feedback Your comments will help us serve your documentation needs better. If you have any suggestions on how to improve this document, complete this form, publication RA-DU002, available at http://www.rockwellautomation.com/literature/. Rockwell Otomasyon Ticaret A.., Kar Plaza Merkezi E Blok Kat:6 34752 çerenköy, stanbul, Tel: +90 (216) 5698400 Publication 2080-SG001D-EN-P - December 2013 62 Supersedes Publication 2080-SG001C-EN-P September 2012 Copyright © 2013 Rockwell Automation, Inc. All rights reserved. Printed in the U.S.A.Acrobat Distiller 11.0 (Windows)