HD 271 S1

LAB02

Test report

NLU Products, LLC dba BGZ brands BLDCTT20 Lantern 2ALQR-BLDCTT20 2ALQRBLDCTT20 bldctt20

PDF Viewing Options

Not Your Device? Search For Manuals or Datasheets below:


File Info : application/pdf, 20 Pages, 2.08MB

Document DEVICE REPORTGetApplicationAttachment.html?id=5066178
JianYan Testing Group Shenzhen Co., Ltd.
Report No: JYTSZE201102602
1 Cover Page
FCC REPORT

Applicant: Address of Applicant:

NLU Products, L.L.C. 2801 N Thanksgiving Way #300, Lehi, UT 84043 USA

Equipment Under Test (EUT)

Product Name:

Lantern

Model No.:

Boulder

Trade mark:

Lander

FCC ID:

2ALQR-BLDCTT20

Applicable standards: FCC CFR Title 47 Part 15 Subpart C Section 15.209

Date of sample receipt: 30 Nov., 2020

Date of Test:

01 Dec., to 09 Dec., 2020

Date of report issue: 10 Dec., 2020

Test Result:

PASS*

* In the configuration tested, the EUT complied with the standards specified above.

Authorized Signature:

Bruce Zhang Laboratory Manager
This report details the results of the testing carried out on one sample. The results contained in this test report do not relate to other samples of the same product and does not permit the use of the JYT product certification mark. The manufacturer should ensure that all products in series production are in conformity with the product sample detailed in this report.
This report may only be reproduced and distributed in full. If the product in this report is used in any configuration other than that detailed in the report, the manufacturer must ensure the new system complies with all relevant standards.
This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery orfalsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only.

2 Version
Version No. 00

Report No: JYTSZE201102602

Date 10 Dec., 2020

Description Original

Tested By:

Test Engineer

Date:

10 Dec., 2020

Reviewed By:

Project Engineer

Date:

10 Dec., 2020

JianYan Testing Group Shenzhen Co., Ltd. No.110~116, Building B, Jinyuan Business Building, Xixiang Road, Bao'an District, Shenzhen, Guangdong, China Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366

Project No.: JYTSZE2011026 Page 2 of 23

Report No: JYTSZE201102602
3 Contents
Page
1 COVER PAGE.............................................................................................................................................................1
2 VERSION .....................................................................................................................................................................2
3 CONTENTS .................................................................................................................................................................3
4 TEST SUMMARY........................................................................................................................................................4
5 GENERAL INFORMATION........................................................................................................................................5
5.1 CLIENT INFORMATION............................................................................................................................................5 5.2 GENERAL DESCRIPTION OF E.U.T........................................................................................................................5 5.3 TEST MODE AND TEST SAMPLES PLANS ................................................................................................................5 5.4 DESCRIPTION OF SUPPORT UNITS........................................................................................................................5 5.5 MEASUREMENT UNCERTAINTY..............................................................................................................................6 5.6 ADDITIONS TO, DEVIATIONS, OR EXCLUSIONS FROM THE METHOD.......................................................................6 5.7 LABORATORY FACILITY..........................................................................................................................................6 5.8 LABORATORY LOCATION .......................................................................................................................................6 5.9 TEST INSTRUMENTSLIST........................................................................................................................................7
6 TEST RESULTS AND MEASUREMENT DATA ......................................................................................................8
6.1 ANTENNA REQUIREMENT .......................................................................................................................................8 6.2 RADIATED EMISSION .............................................................................................................................................9 6.3 CONDUCTED EMISSION .......................................................................................................................................16 6.4 BANDWIDTH .........................................................................................................................................................19
7 TEST SETUP PHOTOS ........................................................................................................................................... 21
8 EUT CONSTRUCTIONAL PHOTOS.......................................................................................................................23

JianYan Testing Group Shenzhen Co., Ltd. No.110~116, Building B, Jinyuan Business Building, Xixiang Road, Bao'an District, Shenzhen, Guangdong, China Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366

Project No.: JYTSZE2011026 Page 3 of 23

Report No: JYTSZE201102602

4 Test Summary

Test Item

Section in CFR 47

Result

Spurious emissions

15.209

Pass

20dB Bandwidth

15.215(c)

Pass

Conducted Emission

15.207

Pass

Remark: 1. Pass: The EUT complies with the essential requirements in the standard. 2. The cable insertion loss used by "RF Output Power" and other conduction measurement items is 0.5dB (provided by
the customer).

Test Method:

ANSI C63.4-2014 ANSI C63.10-2013

JianYan Testing Group Shenzhen Co., Ltd. No.110~116, Building B, Jinyuan Business Building, Xixiang Road, Bao'an District, Shenzhen, Guangdong, China Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366

Project No.: JYTSZE2011026 Page 4 of 23

Report No: JYTSZE201102602

5 General Information

5.1 Client Information
Applicant: Address: Manufacturer: Address: Factory: Address:

NLU Products, L.L.C. 2801 N Thanksgiving Way #300, Lehi, UT 84043 USA NLU Products, L.L.C. 2801 N Thanksgiving Way #300, Lehi, UT 84043 USA CTT Co., Ltd Building 2 of Industrial park, No. 197, Xinhua Blvd, Tongqiao town, Zhongkai High-tech zone, Huizhou, Guangdong, China 516032.

5.2 General Description of E.U.T.

Product Name:

Lantern

Model No.:

Boulder

Operation Frequency:

110kHz ~ 205kHz

Modulation type:

ASK

Antenna Type:

Coil Antenna

Power supply: (Wireless charging)

Input: 5V, 3A / 9V, 2A /12V, 1.5A Output: 5W, 7.5W

Test Sample Condition:

The test samples were provided in good working order with no visible defects.

5.3 Test mode and test samples plans

Transmitting mode:

Keep the EUT in transmitting mode with modulation

5.4 Description of Support Units

Manufacturer

Description

Skytek

Wireless charging match load

Apple

Adapter

Model N/A
A1695

S/N

FCC ID/DoC

N/A

N/A

N/A

N/A

JianYan Testing Group Shenzhen Co., Ltd. No.110~116, Building B, Jinyuan Business Building, Xixiang Road, Bao'an District, Shenzhen, Guangdong, China Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366

Project No.: JYTSZE2011026 Page 5 of 23

Report No: JYTSZE201102602

5.5 Measurement Uncertainty
Parameter Conducted Emission (9kHz ~ 30MHz) Radiated Emission (9kHz ~ 30MHz) Radiated Emission (30MHz ~ 1000MHz) Radiated Emission (1GHz ~ 18GHz) Radiated Emission (18GHz ~ 26.5GHz)

Expanded Uncertainty (Confidence of 95%) ±1.60 dB ±3.12 dB ±4.32 dB ±5.16 dB ±3.20 dB

5.6 Additions to, deviations, or exclusions from the method
No
5.7 Laboratory Facility
The test facility is recognized, certified, or accredited by the following organizations:  FCC - Designation No.: CN1211 JianYan Testing Group Shenzhen Co., Ltd. has been accredited as a testing laboratory by FCC(Federal Communications Commission). The test firm Registration No. is 727551.  ISED ­ CAB identifier.: CN0021 The 3m Semi-anechoic chamber of JianYan Testing Group Shenzhen Co., Ltd. has been Registered by Certification and Engineering Bureau of Industry Canada for radio equipment testing with Registration No.: 10106A-1.  A2LA - Registration No.: 4346.01 This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2005 General requirements for the competence of testing and calibration laboratories. The test scope can be found as below link: https://portal.a2la.org/scopepdf/4346-01.pdf
5.8 Laboratory Location
Shenzhen Zhongjian Nanfang Testing Co., Ltd. Address: No.110~116, Building B, Jinyuan Business Building, Xixiang Road, Bao'an District, Shenzhen, Guangdong, China Tel: +86-755-23118282, Fax: +86-755-23116366 Email: [email protected], Website: http://www.ccis-cb.com

JianYan Testing Group Shenzhen Co., Ltd. No.110~116, Building B, Jinyuan Business Building, Xixiang Road, Bao'an District, Shenzhen, Guangdong, China Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366

Project No.: JYTSZE2011026 Page 6 of 23

5.9 Test Instrumentslist
Radiated Emission:

Test Equipment

Manufacturer

3m SAC BiConiLog Antenna
Horn Antenna Loop Antenna EMI Test Software Pre-amplifier Pre-amplifier Spectrum analyzer EMI Test Receiver Simulated Station
Cable Cable Cable

SAEMC SCHWARZBECK SCHWARZBECK SCHWARZBECK
AUDIX HP CD
Rohde & Schwarz Rohde & Schwarz
Anritsu ZDECL MICRO-COAX SUHNER

Conducted Emission:
Test Equipment
EMI Test Receiver Pulse Limiter LISN LISN Cable
EMI Test Software

Manufacturer
Rohde & Schwarz SCHWARZBECK
CHASE Rohde & Schwarz
HP AUDIX

Report No: JYTSZE201102602

Model No.
9m*6m*6m VULB9163 BBHA9120D FMZB 1519 B
E3 8447D PAP-1G18 FSP30 ESRP7 MT8820C Z108-NJ-NJ-81 MFR64639 SUCOFLEX100

Serial No.
966 497 916 00044 6.110919b 2944A09358 11804 101454 101070 6201026545 1608458 K10742-5 58193/4PE

Cal. Date (mm-dd-yy) 07-22-2020 03-07-2020 03-07-2020 03-07-2020
N/A 03-07-2020 03-07-2020 03-05-2020 03-05-2020 03-07-2020 03-07-2020 03-07-2020 03-07-2020

Cal. Due date (mm-dd-yy) 07-21-2021 03-06-2021 03-06-2021 03-06-2021
N/A 03-06-2021 03-06-2021 03-04-2021 03-04-2021 03-06-2021 03-06-2021 03-06-2021 03-06-2021

Model No.
ESCI OSRAM 2306
MN2050D ESH3-Z5 10503A
E3

Serial No.
101189 9731 1447
8438621/010 N/A
6.110919b

Cal. Date (mm-dd-yy) 03-05-2020 03-05-2020 03-05-2020 07-21-2020 03-05-2020
N/A

Cal. Due date (mm-dd-yy) 03-04-2021 03-04-2021 03-04-2021 07-20-2021 03-04-2021
N/A

JianYan Testing Group Shenzhen Co., Ltd. No.110~116, Building B, Jinyuan Business Building, Xixiang Road, Bao'an District, Shenzhen, Guangdong, China Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366

Project No.: JYTSZE2011026 Page 7 of 23

Report No: JYTSZE201102602

6 Test results and Measurement Data

6.1 Antenna requirement

Standard requirement: FCC Part15 C Section 15.203

15.203 requirement: An intentional radiator shall be designed to ensure that no antenna other than that furnished by the responsible party shall be used with the device. The use of a permanently attached antenna or of an antenna that uses a unique coupling to the intentional radiator, the manufacturer may design the unit so that a broken antenna can be replaced by the user, but the use of a standard antenna jack or electrical connector is prohibited.

E.U.T Antenna:

Coil antenna

JianYan Testing Group Shenzhen Co., Ltd. No.110~116, Building B, Jinyuan Business Building, Xixiang Road, Bao'an District, Shenzhen, Guangdong, China Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366

Project No.: JYTSZE2011026 Page 8 of 23

Report No: JYTSZE201102602

6.2 Radiated Emission

Test Requirement: Test Frequency Range: Test site: Receiver setup: Limit:
Test Procedure:
Test setup:

FCC Part15 C Section 15.209

9kHz to 1000MHz

Measurement Distance: 3m(Semi-Anechoic Chamber)

Frequency

Detector

9kHz-150kHz Quasi-peak

RBW 200Hz

VBW

Remark

600Hz Quasi-peak Value

150kHz30MHz 30MHz-1GHz

Quasi-peak Quasi-peak

9kHz 30kHz Quasi-peak Value 120kHz 300kHz Quasi-peak Value

Above 1GHz

Peak

1MHz 3MHz

Peak Value

Frequency (MHz)

Limit (uV/m @3m)

Distance (m)

0.009-0.490

2400/F(kHz)

300

0.490-1.705

24000/F(kHz)

30

1.705-30

30

30

30-88

100

3

88-216

150

3

216-960

200

3

Above 1GHz

500

3

a. The EUT was placed on the top of a rotating table 0.8 meters above the

groundat a 3 meter semi-anechoic camber. The table was rotated 360

degrees todetermine the position of the highest radiation.

b. The EUT was set 3 meters away from the interference-receiving antenna,

whichwas mounted on the top of a variable-height antenna tower.

c. The antenna height is varied from one meter to four meters above the ground

to determine the maximum value of the field strength. Both horizontal and

vertical polarizations of the antenna are set to make the measurement.

d. For each suspected emission, the EUT was arranged to its worst case and

thenthe antenna was tuned to heights from 1 meter to 4 meters and the

rotatabletable was turned from 0 degrees to 360 degrees to find the maximum

reading.

e. The test-receiver system was set to Peak Detect Function and

SpecifiedBandwidth with Maximum Hold Mode.

f. If the emission level of the EUT in peak mode was 10dB lower than the

limitspecified, then testing could be stopped and the peak values of the EUT

wouldbe reported. Otherwise the emissions that did not have 10dB margin

would bere-tested one by one using peak, quasi-peak or average method as

specified andthen reported in a data sheet.

9kHz-30MHz

30MHz-1GHz
JianYan Testing Group Shenzhen Co., Ltd. No.110~116, Building B, Jinyuan Business Building, Xixiang Road, Bao'an District, Shenzhen, Guangdong, China Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366

Project No.: JYTSZE2011026 Page 9 of 23

Report No: JYTSZE201102602

Test Instruments: Test mode: Test results: Remark:

Refer to section 5.9 for details Refer to section 5.3 for details Pass The emission levels of above 1 GHz are very lower than the limit and not show in test report.

JianYan Testing Group Shenzhen Co., Ltd. No.110~116, Building B, Jinyuan Business Building, Xixiang Road, Bao'an District, Shenzhen, Guangdong, China Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366

Project No.: JYTSZE2011026 Page 10 of 23

Measurement Data: a) Fundamental field strength

Test Polarization
Horizontal Vertical

Frequency (kHz)
143.25 143.25

Test Polarization
Horizontal Vertical

Frequency (kHz)
143.25 143.25

Peak value
H-field@3m (dBV)
62.34 67.15 Average value
H-field@3m (dBV)
45.19 51.37

Report No: JYTSZE201102602

Limit@3m (dBV) 81.49 81.49
Limit@3m (dBV) 61.49 61.49

Result Pass Pass
Result Pass Pass

JianYan Testing Group Shenzhen Co., Ltd. No.110~116, Building B, Jinyuan Business Building, Xixiang Road, Bao'an District, Shenzhen, Guangdong, China Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366

Project No.: JYTSZE2011026 Page 11 of 23

b) Radiated spurious: Below 1GHz:

Product Name:

Lantern

Test By:

YT

Test Frequency: 9kHz~30MHz

Test Voltage:

AC 120V/60Hz

Fundamental signal

Report No: JYTSZE201102602

Product Model: Test mode: Polarization: Environment:

Boulder

Charing mode

Vertical Temp: 24

Huni: 57%

Remark: 1. Final Level = Receiver Read level + Antenna Factor + Cable Loss ­ Preamplifier Factor. 2. The emission levels of other frequencies are very lower than the limit and not show in test report.

JianYan Testing Group Shenzhen Co., Ltd. No.110~116, Building B, Jinyuan Business Building, Xixiang Road, Bao'an District, Shenzhen, Guangdong, China Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366

Project No.: JYTSZE2011026 Page 12 of 23

Product Name: Test By: Test Frequency: Test Voltage:

Lantern YT 9kHz~30MHz AC 120V/60Hz

Fundamental signal

Report No: JYTSZE201102602

Product Model: Test mode: Polarization: Environment:

Boulder Charing mode Horizontal Temp: 24 Huni: 57%

Remark: 1. Final Level = Receiver Read level + Antenna Factor + Cable Loss ­ Preamplifier Factor. 2. The emission levels of other frequencies are very lower than the limit and not show in test report.

JianYan Testing Group Shenzhen Co., Ltd. No.110~116, Building B, Jinyuan Business Building, Xixiang Road, Bao'an District, Shenzhen, Guangdong, China Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366

Project No.: JYTSZE2011026 Page 13 of 23

Product Name: Test By: Test Frequency: Test Voltage:

Lantern YT 30 MHz ~ 1 GHz AC 120V/60Hz

Report No: JYTSZE201102602

Product Model: Test mode: Polarization: Environment:

Boulder Charing mode Vertical Temp: 24

Huni: 57%

Remark: 1. Final Level = Receiver Read level + Antenna Factor + Cable Loss + Aux Factor ­ Preamplifier Factor. 2. The emission levels of other frequencies are very lower than the limit and not show in test report. 3. The Aux Factor is a notch filter switch box loss, this item is not used.

JianYan Testing Group Shenzhen Co., Ltd. No.110~116, Building B, Jinyuan Business Building, Xixiang Road, Bao'an District, Shenzhen, Guangdong, China Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366

Project No.: JYTSZE2011026 Page 14 of 23

Product Name: Test By: Test Frequency: Test Voltage:

Lantern YT 30 MHz ~ 1 GHz AC 120V/60Hz

Report No: JYTSZE201102602

Product Model: Test mode: Polarization: Environment:

Boulder Charing mode Horizontal Temp: 24 Huni: 57%

Remark: 1. Final Level = Receiver Read level + Antenna Factor + Cable Loss + Aux Factor ­ Preamplifier Factor. 2. The emission levels of other frequencies are very lower than the limit and not show in test report. 3. The Aux Factor is a notch filter switch box loss, this item is not used.

JianYan Testing Group Shenzhen Co., Ltd. No.110~116, Building B, Jinyuan Business Building, Xixiang Road, Bao'an District, Shenzhen, Guangdong, China Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366

Project No.: JYTSZE2011026 Page 15 of 23

Report No: JYTSZE201102602

6.3 Conducted Emission

Test Requirement: Test Frequency Range: Class / Severity: Receiver setup: Limit:
Test setup:

FCC Part 15 B Section 15.207

150kHz to 30MHz

Class B

Class B

RBW=9kHz, VBW=30kHz

Frequency range (MHz)

Limit (dBµV)

Quasi-peak

Average

0.15-0.5

66 to 56*

56 to 46*

0.5-5

56

46

0.5-30

60

50

* Decreases with the logarithm of the frequency.

Test procedure
Test environment: Test Instruments: Test mode: Test results:

1. The E.U.T and simulators are connected to the main power through a line impedance stabilization network(L.I.S.N.). The provide a 50ohm/50uH coupling impedance for the measuring equipment.

2. The peripheral devices are also connected to the main power through a LISN that provides a 50ohm/50uH coupling impedance with 50ohm termination. (Please refers to the block diagram of the test setup and photographs).
3. Both sides of A.C. line are checked for maximum conducted interference. In order to find the maximum emission, the relative positions of equipment and all of the interface cables must be changed according to ANSI C63.4: 2014 on conducted measurement.

Temp.: 23 C

Humid.: 56%

Press.: 101kPa

Refer to section 5.9 for details

Refer to section 5.3 for details

Pass

JianYan Testing Group Shenzhen Co., Ltd. No.110~116, Building B, Jinyuan Business Building, Xixiang Road, Bao'an District, Shenzhen, Guangdong, China Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366

Project No.: JYTSZE2011026 Page 16 of 23

Measurement data: Product name: Test by: Test frequency: Test voltage:

Lantern YT 150 kHz ~ 30 MHz AC 120 V/60 Hz

Report No: JYTSZE201102602

Product Model: Test mode: Phase: Environment:

Boulder Charing mode Line Temp: 22.5

Huni: 55%

Notes: 1. An initial pre-scan was performed on the line and neutral lines with peak detector. 2. Quasi-Peak and Average measurement were performed at the frequencies with maximized peak emission. 3. Final Level =Receiver Read level + LISN Factor + Cable Loss.

JianYan Testing Group Shenzhen Co., Ltd. No.110~116, Building B, Jinyuan Business Building, Xixiang Road, Bao'an District, Shenzhen, Guangdong, China Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366

Project No.: JYTSZE2011026 Page 17 of 23

Product name: Test by: Test frequency: Test voltage:

Lantern YT 150 kHz ~ 30 MHz AC 120 V/60 Hz

Report No: JYTSZE201102602

Product Model: Test mode: Phase: Environment:

Boulder Charing mode Neutral Temp: 22.5

Huni: 55%

Notes: 1. An initial pre-scan was performed on the line and neutral lines with peak detector. 2. Quasi-Peak and Average measurement were performed at the frequencies with maximized peak emission. 3. Final Level =Receiver Read level + LISN Factor + Cable Loss.

JianYan Testing Group Shenzhen Co., Ltd. No.110~116, Building B, Jinyuan Business Building, Xixiang Road, Bao'an District, Shenzhen, Guangdong, China Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366

Project No.: JYTSZE2011026 Page 18 of 23

6.4 Bandwidth
Test Requirement: Receiver setup: Limit:
Test Procedure:

Report No: JYTSZE201102602
FCC Part15 C Section 15.215 (c) RBW=1 kHz, VBW=3 kHz, detector: Peak The fundamental emission be kept within at least the central 80% of the permitted band 1. According to the follow Test-setup, keep the relative position between
the artificial antenna and the EUT. 2. Set the EUT to proper test channel. 3. Max hold the radiated emissions, mark the peak power frequency
point and the -20dB upper and lower frequency points. 4. Read 20dB bandwidth.

Test setup:

Test Instruments: Test mode: Test results:

Refer to section 5.9 for details Refer to section 5.3 for details Passed

Measurement Data
Test CH Lowest Highest Test CH Lowest Highest Remark: For report purpose only.

20dB Emission Bandwidth (kHz) 2.78 2.70
99% Occupy Bandwidth (kHz) 2.32 2.36

Limit(kHz) N/A
Limit(kHz) N/A

JianYan Testing Group Shenzhen Co., Ltd. No.110~116, Building B, Jinyuan Business Building, Xixiang Road, Bao'an District, Shenzhen, Guangdong, China Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366

Project No.: JYTSZE2011026 Page 19 of 23

Test plot as follows:

Ref 108 dBµV

* Att

Offset 1 dB

100

D1 102.05 dBµV

10 dB

1 PK MAXH 90
80

1 D2 82.05 dBµV

20dB
* RBW 1 kHz * VBW 3 kHz
SWT 20 ms

Delta 2 [T1 ] -0.12 dB
2.780000000 kHz
Marker 1 [T1 ] 81.25 dBµV
110.560000000 kHz A

LVL 2

70

60 3DB
50

40

30

20

10 Center 111.6 kHz

1 kHz/

Span 10 kHz

Date: 7.DEC.2020 09:41:19
Test Frequency= 111.60 kHz

Ref 108 dBµV Offset 1 dB
100

* Att 10 dB

1 PK MAXH 90
80

D1 82.52 dBµV

* RBW 1 kHz * VBW 3 kHz
SWT 20 ms

Delta 2 [T1 ] -0.51 dB
2.700000000 kHz
Marker 1 [T1 ] 62.07 dBµV
173.520000000 kHz A

LVL

70

1

2

D2 62.52 dBµV

60

50

3DB

40

30

20

10 Center 174.9 kHz

1 kHz/

Span 10 kHz

Date: 7.DEC.2020 10:23:59
Test Frequency= 174.90 kHz

Report No: JYTSZE201102602

Ref 108 dBµV Offset 1 dB
100 1 PK MAXH 90
80
70
60
50
40
30
20
10 Center 111.6 kHz

99% OBW

* Att 10 dB T1

* RBW 1 kHz * VBW 3 kHz
SWT 20 ms 1
T2

Marker 1 [T1 ] 102.05 dBµV
111.980000000 kHz
OBW 2.320000000 kHz Temp 1 [T1 OBW]
86.86 dBµV A 110.780000000 kHz Temp 2 [T1 OBW]
86.76 dBµV LVL 113.100000000 kHz

3DB

1 kHz/

Span 10 kHz

Date: 7.DEC.2020 09:40:25
Test Frequency= 111.60 kHz

Ref 108 dBµV Offset 1 dB
100 1 PK MAXH 90
80
70
60
50
40
30
20
10 Center 174.9 kHz

* Att 10 dB

* RBW 1 kHz * VBW 3 kHz
SWT 20 ms

1

Marker 1 [T1 ] 82.10 dBµV
174.860000000 kHz
OBW 2.360000000 kHz Temp 1 [T1 OBW]
67.38 dBµV A 173.660000000 kHz Temp 2 [T1 OBW]
66.24 dBµV LVL 176.020000000 kHz

T1 T2

3DB

1 kHz/

Span 10 kHz

Date: 7.DEC.2020 10:23:25
Test Frequency= 174.90 kHz

JianYan Testing Group Shenzhen Co., Ltd. No.110~116, Building B, Jinyuan Business Building, Xixiang Road, Bao'an District, Shenzhen, Guangdong, China Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366

Project No.: JYTSZE2011026 Page 20 of 23



Related FCC IDs: