Marco Cristini

Test Report DTS

Datalogic S.r.l. SIRIUS915 Radio module U4F-SIRIUS915 U4FSIRIUS915 sirius915

PDF Viewing Options

Not Your Device? Search For Manuals or Datasheets below:


File Info : application/pdf, 38 Pages, 1.25MB

Document DEVICE REPORTGetApplicationAttachment.html?id=7988958
PRS LAB S.r.l. Unipersonale
Sede operativa e Laboratori di prova Headquarter and Testing lab Via Campagna, 92 I 22020 Faloppio (CO) I Italy Tel. +39 031 3500011 I Fax +39 031 991309 [email protected] I www.primaricerca.it
TEST REPORT

Ref. n.

FCCTR_185700-0 Issue Date:

26/11/2024

Pages:

38

Test object Applicant Trade mark

Type test according to Standards 47 CFR FCC Part 15 Subpart C §15.247
DATALOGIC S.r.l. Via S. Vitalino 13 - 40012 Lippo Di Calderara Di Reno - Bologna - Italy Phone. +39 051 3147196 Fax +39 051 3147561

Manufacturer Product Tested model FCC Identification number

DATALOGIC S.r.l. Radio module SIRIUS STAR RADIO, 915MHZ U4F-SIRIUS915

Date of test samples receipt No. of tested samples Test date Testing site FCC designation number Test results

16/10/2024 1 ­ Sampled by the manufacturer From 29/10/2024 to 12/11/2024 PRSLAB S.r.l. Unipersonale - Via Campagna 92 - 22020 Faloppio - Como - Italy IT0012 COMPLIANT

Verifications carried out by

Daniele AOSANI Laboratory Engineer

Approved by

Luana PARISI Reviewer

The test results reported in this test report shall refer only to the samples tested. The sample has been provided by the customer and the results apply to the sample as received. This report may not be partially reproduced, except with the prior written permission of the issuing Laboratory. PRS refuses any responsibility about information provided by the customer contained in this test report.

Mod 18_48 rev06 Test Report FCCTR

Test report n. FCCTR_185700-0 I Date 26/11/2024

Page 1 di 38

PRS LAB S.r.l. Unipersonale
Sede operativa e Laboratori di prova Headquarter and Testing lab: Via Campagna, 92 I 22020 Faloppio (CO) I Italy Tel. +39 031 3500011 I Fax +39 031 991309 [email protected] I www.primaricerca.it
TABLE OF CONTENTS
0. RELEASE CONTROL RECORD ..................................................................................................... 3 1. DECISION RULE ........................................................................................................................ 3 2. INFORMATION PROVIDED BY CUSTOMER................................................................................. 3 3. GENERAL REMARKS ................................................................................................................. 3 4. TECHNICAL INFORMATION OF EQUIPMENT UNDER TEST (EUT) ................................................. 4
4.1 EUT Identification ......................................................................................................................... 4 4.2 Radio module technical data ........................................................................................................ 5 4.3 Ports identification........................................................................................................................ 6 4.4 Modifications incorporated in E.U.T............................................................................................. 6 4.5 Auxiliary equipment...................................................................................................................... 6 5. OPERATING MODES AND TEST CONDITIONS............................................................................. 6 6. REFERENCE STANDARDS .......................................................................................................... 7 7. UNITS OF MEASUREMENTS ...................................................................................................... 7 8. SUMMARY OF TEST RESULTS .................................................................................................... 8 9. TESTS RESULTS ......................................................................................................................... 9

Mod 18_48 rev06 Test Report FCCTR

Test report n. FCCTR_185700-0 I Date 26/11/2024

Page 2 di 38

PRS LAB S.r.l. Unipersonale
Sede operativa e Laboratori di prova Headquarter and Testing lab: Via Campagna, 92 I 22020 Faloppio (CO) I Italy Tel. +39 031 3500011 I Fax +39 031 991309 [email protected] I www.primaricerca.it
0. RELEASE CONTROL RECORD

TEST REPORT NUMBER

REASON OF CHANGE

DATE OF ISSUE

FCCTR_185700-0

Original release

26/11/2024

This document is valid in last revision that deletes and replaces the previous one

1. DECISION RULE
PRS LAB specifies that, if the decision rules of conformity of the test results are not indicated in detail in the standard/s object of tests, it takes as a decision rule for the declaration of conformity the simple binary system (w = 0) stated in the ILAC-G8-09:2019 document. The decision rule is applicable for all parts of standard

Statements of conformity are reported as: - Pass: the measured value is below the acceptance limit, =. - Fail: the measured value is above the acceptance limit, =.
Definitions - Guard Band (w): interval between a tolerance limit and a corresponding acceptance limit where length =|-|. - Tolerance Limit (TL) (Specification Limit): specified upper or lower bound of permissible values of a property. - Acceptance Limit (AL): specified upper or lower bound of permissible measured quantity values.
2. INFORMATION PROVIDED BY CUSTOMER
· None
3. GENERAL REMARKS
· None

Mod 18_48 rev06 Test Report FCCTR

Test report n. FCCTR_185700-0 I Date 26/11/2024

Page 3 di 38

PRS LAB S.r.l. Unipersonale
Sede operativa e Laboratori di prova Headquarter and Testing lab: Via Campagna, 92 I 22020 Faloppio (CO) I Italy Tel. +39 031 3500011 I Fax +39 031 991309 [email protected] I www.primaricerca.it

4. TECHNICAL INFORMATION OF EQUIPMENT UNDER TEST (EUT)
4.1 EUT Identification

DESCRIPTION MODEL NAME FCC ID SERIAL NO. PRS LAB INTERNAL REFERENCE

Radio module SIRIUS STAR RADIO, 915MHZ U4F-SIRIUS915 B24PAAFEY00001040 BC 267/2024 3/15

TRADEMARK

MANUFACTURER

DATALOGIC S.r.l.

COUNTRY OF MANUFACTURER Italy

SINGLE UNIT OR SYSTEM

Single

POWER SOURCE

DC power from board

SUPPLY VOLTAGE

3.0 ÷ 3.6Vdc, Typical 3.3Vdc

OPERATING TEMPERATURE
HARDWARE VERSION
(Information provided by Customer)
FIRMWARE VERSION
(Information provided by Customer)

-30°C ÷ +85°C A A

DIMENSIONS

See photographic documentation

EUT STANDING
HIGHEST INTERNAL FREQUENCY
(Information provided by Customer)

WALL; CEILING; TABLE; FLOOR; RACK MOUNTED; BODY WORN; HANDELD; PORTABLE; MOBILE
<108MHz; 108MHz<F<500MHz; 500MHz<F<1GHz; F>1GHz; F = 926.936MHz

Mod 18_48 rev06 Test Report FCCTR

Test report n. FCCTR_185700-0 I Date 26/11/2024

Page 4 di 38

PRS LAB S.r.l. Unipersonale
Sede operativa e Laboratori di prova Headquarter and Testing lab: Via Campagna, 92 I 22020 Faloppio (CO) I Italy Tel. +39 031 3500011 I Fax +39 031 991309 [email protected] I www.primaricerca.it
4.2 Radio module technical data

ETS CATEGORY
FREQUENCY BAND
WORKING FREQUENCY
NUMBER OF CHANNELS
CHANNEL OCCUPIED BANDWIDTH
CHANNEL SPACING
TYPE OF MODULATION
DATA RATE ANTENNA TYPE
(Information provided by Customer)
ANTENNA GAIN
(Information provided by Customer)
ANTENNA MODEL
(Information provided by Customer)
ANTENNA MANUFACTURER
(Information provided by Customer)

Digital Transmission System (DTS) - Transceiver From 902MHz to 928MHz 910MHz 1 1.16MHz --NRZ 500000 bit/s Flexible antenna with cable SRFI068H-100 with peak gain of 0.2dBi SRFI068V-100 with peak gain of 0.7dBi

Mod 18_48 rev06 Test Report FCCTR

Test report n. FCCTR_185700-0 I Date 26/11/2024

Page 5 di 38

PRS LAB S.r.l. Unipersonale
Sede operativa e Laboratori di prova Headquarter and Testing lab: Via Campagna, 92 I 22020 Faloppio (CO) I Italy Tel. +39 031 3500011 I Fax +39 031 991309 [email protected] I www.primaricerca.it

4.3 Ports identification

PORT Enclosure AC power port DC power port Signal/control port Telecommunication port Antenna port

DESCRIPTION Electronic board Port not present 3.3Vdc Port not present Port not present
Internal; External

CONNECTION ----PIN stripe ----UFL

NOTES -------------

Note: During the tests all cables must be what provided the manufacturer or the same that used in the real employment of the EUT.

4.4 Modifications incorporated in E.U.T.
The following items are the modifications introduced in the equipment under test: · None
4.5 Auxiliary equipment
· Auxiliary laboratory laptop used to set radio channels. · Auxiliary board to supply radio module and send command via USB connected to

5. OPERATING MODES AND TEST CONDITIONS
In the following table there are the operating conditions adopted during tests identified by an indicator (#) at which has been referred the item "Operating condition of the equipment under test"

OPERATING CONDITION DESCRIPTION

#1

Continuous transmission, modulated carrier at 910MHz

Special Test Software: Special software by the Applicant to operate the EUT at each channel frequency continuously. For example, the transmitter will be operated at each of the lowest, middle and highest frequencies individually continuously during testing.
Special Hardware Used: None
Transmitter Test Antenna: The EUT was tested with two antennas, one at a time, mounted in a typical manner for its normal intended use as external antenna equipment.

Mod 18_48 rev06 Test Report FCCTR

Test report n. FCCTR_185700-0 I Date 26/11/2024

Page 6 di 38

PRS LAB S.r.l. Unipersonale
Sede operativa e Laboratori di prova Headquarter and Testing lab: Via Campagna, 92 I 22020 Faloppio (CO) I Italy Tel. +39 031 3500011 I Fax +39 031 991309 [email protected] I www.primaricerca.it
6. REFERENCE STANDARDS

REFERENCE STANDARD

DESCRIPTION

47 CFR FCC Part 15 Subpart C §15.247

Radio Frequency Devices ­ Intentional Radiators Operation within the bands 902-928 MHz, 2400-2483.5 MHz, and 5725-5850 MHz

KDB 558074 D01

Guidance for compliance measurements on Digital Transmission Systems (DTS), Frequency Hopping Spread Spectrum System (DSS) and Hybrid System Device (DSS) operating under §15.247 of the FCC rules.

ANSI C63.10:2020; ANSI C63.10:2020/Cor.1:2023

American National Standard of Procedures for Compliance Testing of Unlicensed Wireless Devices

ANSI C63.4:2014

American National Standard for Methods of Measuring of Radio-Noise Emissions from Low-Voltage Electrical and Electronic Equipment in the Range of 9 kHz ­ 40 GHz

7. UNITS OF MEASUREMENTS
Conducted EMI Data is in dBµV; dB referenced to one microvolt Radiated EMI Data is in dBµV/m; dB/m referenced to one microvolt per meter
Sample Calculation: RFS = Radiated Field Strength, FSM = Field Strength Measured, A.F. = Receive antenna factor, Gain = amplification gains and/or cable losses.
RFS (dBµV/m @ 3m) = FSM (dBµV) + A.F. (dB/m) ­ Gain (dB)

Mod 18_48 rev06 Test Report FCCTR

Test report n. FCCTR_185700-0 I Date 26/11/2024

Page 7 di 38

PRS LAB S.r.l. Unipersonale
Sede operativa e Laboratori di prova Headquarter and Testing lab: Via Campagna, 92 I 22020 Faloppio (CO) I Italy Tel. +39 031 3500011 I Fax +39 031 991309 [email protected] I www.primaricerca.it
8. SUMMARY OF TEST RESULTS

EUT PORT

DESCRIPTION OF PHENOMENA

BASIC STANDARD

Antenna requirement

FCC Part 15 §15.203

Maximum Peak Output Power

FCC Part 15 §15.247 (b) (3)

6dB Bandwidth

FCC Part 15 §15.247 (a) (2)

Power Spectral Density

FCC Part 15 §15.247 (e)

Antenna port

Band-Edge

FCC Part 15 § 15.247 (d)

RF radiated Spurious Emissions at the Transmitter Antenna Terminal

FCC Part 15 § 15.247 (d)

Transmitter Radiated Emissions <1GHz

FCC Part 15 § 15.247 (d) & § 15.249
(a)

Transmitter Radiated Emissions >1GHz
Note: 1 Ref. Tab. Of Section 5

FCC Part 15 § 15.247 (d) & § 15.249
(a)

OPERATING CONDITION1
--#1 #1 #1 #1 #1
#1
#1

RESULTS Compliant Within the limits Within the limits Within the limits Within the limits Within the limits Within the limits
Within the limits

Mod 18_48 rev06 Test Report FCCTR

Test report n. FCCTR_185700-0 I Date 26/11/2024

Page 8 di 38

PRS LAB S.r.l. Unipersonale
Sede operativa e Laboratori di prova Headquarter and Testing lab: Via Campagna, 92 I 22020 Faloppio (CO) I Italy Tel. +39 031 3500011 I Fax +39 031 991309 [email protected] I www.primaricerca.it
9. TESTS RESULTS
ANTENNA REQUIREMENTS ........................................................................................................... 10 MAXIMUM PEAK OUTPUT POWER................................................................................................ 11 POWER SPECTRAL DENSITY........................................................................................................... 14 6dB CHANNEL BANDWIDTH .......................................................................................................... 17 BAND EDGE .................................................................................................................................. 20 RF RADIATED SPURIOUS EMISSIONS AT THE TRANSMITTER ANTENNA TERMINAL ......................... 22 TRANSMITTER RADIATED EMISSIONS < 1GHz ................................................................................ 24 TRANSMITTER RADIATED EMISSIONS > 1GHz ................................................................................ 32

Mod 18_48 rev06 Test Report FCCTR

Test report n. FCCTR_185700-0 I Date 26/11/2024

Page 9 di 38

TEST 1.
REFERENCE DOCUMENT

PRS LAB S.r.l. Unipersonale
Sede operativa e Laboratori di prova Headquarter and Testing lab: Via Campagna, 92 I 22020 Faloppio (CO) I Italy Tel. +39 031 3500011 I Fax +39 031 991309 [email protected] I www.primaricerca.it
ANTENNA REQUIREMENTS
According to §15.203 / 15.204 An intentional radiator shall be designed to ensure that no antenna other than that furnished by the responsible party shall be used with the device. The use of a permanently attached antenna or of an antenna that uses a unique coupling to the intentional radiator shall be considered sufficient to comply with the provisions of this section. The manufacturer may design the unit so that a broken antenna can be replaced by the user, but the use of a standard antenna jack or electrical connector is prohibited. This requirement does not apply to carrier current devices or to devices operated under the provisions of Sec. 15.211, Sec. 15.213, Sec. 15.217, Sec. 15.219, or Sec. 15.221. Further, this requirement does not apply to intentional radiators that must be professionally installed, such as perimeter protection systems and some field disturbance sensors, or to other intentional radiators which, in accordance with Sec. 15.31(d), must be measured at the installation site. However, the installer shall be responsible for ensuring that the proper antenna is employed so that the limits in this part are not exceeded
Antenna Requirements
The EUT has two external flexible antennas with cable.
RESULT: COMPLIANT

Mod 18_48 rev06 Test Report FCCTR

Test report n. FCCTR_185700-0 I Date 26/11/2024

Page 10 di 38

TEST 2.
REFERENCE DOCUMENT

PRS LAB S.r.l. Unipersonale
Sede operativa e Laboratori di prova Headquarter and Testing lab: Via Campagna, 92 I 22020 Faloppio (CO) I Italy Tel. +39 031 3500011 I Fax +39 031 991309 [email protected] I www.primaricerca.it
MAXIMUM PEAK OUTPUT POWER
According to §15.247(b) (3) For systems using digital modulation in the 902-928 MHz, 2400-2483.5 MHz, and 5725-5850 MHz bands: 1 Watt. As an alternative to a peak power measurement, compliance with the one Watt limit can be based on a measurement of the maximum conducted output power. Maximum Conducted Output Power is defined as the total transmit power delivered to all antennas and antenna elements averaged across all symbols in the signalling alphabet when the transmitter is operating at its maximum power control level. Power must be summed across all antennas and antenna elements. The average must not include any time intervals during which the transmitter is off or is transmitting at a reduced power level. If multiple modes of operation are possible (e.g., alternative modulation methods), the maximum conducted output power is the highest total transmit power occurring in any mode.

· TEST LOCATION · DISTANCE OF MEASUREMENT · TYPE OF MEASUREMENT · TEST EQUIPMENT USED FOR TEST
· TESTED PORT · TEST METHOD · FREQUENCY RANGE · UNCERTAINTY OF MEASURE

Semi-Anechoic Chamber

3m

Radiated

Instrument Manufacturer Model

Serial n°

Calibrated On Due to

MXE Emi Receiver

Keysight

N9038A

MY57290150

11/2023

11/2024

Semi-Anechoic Chamber

Siemens

B83117D6019-T232

003-005134/94C

02/2024

02/2025

Horn antenna Electro Metrics EM-6961

6278

10/2023

10/2026

Software EMC

Rohde & Schwarz

EMC32-E

V 8.40.0

N.A.

Antenna

ANSI C63.10:2020; ANSI C63.10:2020/Cor.1:2023 section 11.9

Carrier

Level of confidence = 95% (k=2) Expanded uncertainty = 5,15 dB

TEST CONDITIONS Ambient temperature Ambient humidity Pressure

REQUIRED 23°C  5°C 25 - 75%rH 86 - 106kPa (860mbar - 1060mbar)

MEASURED 24 °C 45% 1014 mbar

OPERATING CONDITION: #1 RESULT: WITHIN THE LIMITS

Mod 18_48 rev06 Test Report FCCTR

Test report n. FCCTR_185700-0 I Date 26/11/2024

Page 11 di 38

Resolution bandwidth Video bandwidth Span Sweep time Detector Trace-Mode

PRS LAB S.r.l. Unipersonale
Sede operativa e Laboratori di prova Headquarter and Testing lab: Via Campagna, 92 I 22020 Faloppio (CO) I Italy Tel. +39 031 3500011 I Fax +39 031 991309 [email protected] I www.primaricerca.it
MEASUREMENT PARAMETER
RBW  DTS bandwidth
VBW  3 x RBW
span  3 x RBW
Auto couple
Peak
Max. hold

TEST DESCRIPTION
Measurement is made at a semi-anechoic chamber that incorporates a turntable allowing a EUT rotation of 360°. A continuously - rotating, remotely - controlled turntable is installed at the test site to support the EUT and facilitate determination of the direction of maximum radiation for each EUT emission frequency.
The EUT is placed at test table.
For emissions testing at or below 1 GHz, the table height is 80 cm above the reference ground plane. For emission measurements above 1 GHz, the table height is 1.5 m
Measurement is made with the antenna positioned in both the horizontal and vertical planes of polarization. The measurement antenna is varied in height (1m~4m) above the reference ground plane to obtain the maximum signal strength. Distance between EUT and antenna is 3m.
This investigation is performed with the EUT rotated 360°, the antenna height scanned between 1 m and 4 m, and the antenna rotated to repeat the measurements for both the horizontal and vertical antenna polarizations.

TEST SETUP BLOCK DIAGRAM SEMI ANECHOIC CHAMBER

EMI RECEIVER

EUT

Mod 18_48 rev06 Test Report FCCTR

Test report n. FCCTR_185700-0 I Date 26/11/2024

Page 12 di 38

Channel Frequency (MHz)

-Note: ---

910.00

PRS LAB S.r.l. Unipersonale
Sede operativa e Laboratori di prova Headquarter and Testing lab: Via Campagna, 92 I 22020 Faloppio (CO) I Italy Tel. +39 031 3500011 I Fax +39 031 991309 [email protected] I www.primaricerca.it
TEST RESULTS

Radiated power with antenna SRFI068H-100

EIRP (dBm)

Antenna Gain

Max

Conducted

(dB)

Output power

14.74

0.2

14.54

Limit (dBm)
30

Result
WITHIN THE LIMITS

Channel Frequency (MHz)

-Note: ---

910.00

Radiated power with antenna SRFI068V-100

EIRP (dBm)

Antenna Gain

Max

Conducted

(dB)

Output power

15.24

0.7

14.54

Limit (dBm)
30

Result
WITHIN THE LIMITS

Mod 18_48 rev06 Test Report FCCTR

Test report n. FCCTR_185700-0 I Date 26/11/2024

Page 13 di 38

TEST 3.
REFERENCE DOCUMENT

PRS LAB S.r.l. Unipersonale
Sede operativa e Laboratori di prova Headquarter and Testing lab: Via Campagna, 92 I 22020 Faloppio (CO) I Italy Tel. +39 031 3500011 I Fax +39 031 991309 [email protected] I www.primaricerca.it
POWER SPECTRAL DENSITY
According to §15,247) (e) For digitally modulated systems, the power spectral density conducted from the intentional radiator to the antenna shall not be greater than 8 dBm in any 3 kHz band during any time interval of continuous transmission. This power spectral density shall be determined in accordance with the provisions of paragraph (b) of this section. The same method of determining the conducted output power shall be used to determine the power spectral density.

· TEST LOCATION · TYPE OF MEASUREMENT · TEST EQUIPMENT USED FOR TEST
· TESTED PORT · TEST METHOD · FREQUENCY RANGE

Radio test area

Conducted

Instrument Emi Receiver
Antenna

Manufacturer
Rohde & Schwarz

Model ESU 40

Serial n° 100111

Calibrated On Due to

03/2024

03/2025

ANSI C63.10:2020; ANSI C63.10:2020/Cor.1:2023 section 11.10

Carrier

TEST CONDITIONS Ambient temperature Ambient humidity Pressure

REQUIRED 23°C  5°C 25 - 75%rH 86 - 106kPa (860mbar - 1060mbar)

MEASURED 24 °C 45% 1014 mbar

OPERATING CONDITION: #1

RESULT: COMPLIANT

Mod 18_48 rev06 Test Report FCCTR

Test report n. FCCTR_185700-0 I Date 26/11/2024

Page 14 di 38

Resolution bandwidth Video bandwidth Span Sweep time Detector Trace-Mode

PRS LAB S.r.l. Unipersonale
Sede operativa e Laboratori di prova Headquarter and Testing lab: Via Campagna, 92 I 22020 Faloppio (CO) I Italy Tel. +39 031 3500011 I Fax +39 031 991309 [email protected] I www.primaricerca.it

3kHz 10kHz 1.5MHz Auto couple Peak Max. hold

MEASUREMENT PARAMETER

TEST DESCRIPTION
Allow trace to fully stabilize. Use the peak marker function to determine the maximum amplitude level within the RBW. If measured value exceeds limit, reduce RBW (no less than 3 kHz) and repeat

Mod 18_48 rev06 Test Report FCCTR

Test report n. FCCTR_185700-0 I Date 26/11/2024

Page 15 di 38

PRS LAB S.r.l. Unipersonale
Sede operativa e Laboratori di prova Headquarter and Testing lab: Via Campagna, 92 I 22020 Faloppio (CO) I Italy Tel. +39 031 3500011 I Fax +39 031 991309 [email protected] I www.primaricerca.it
TEST RESULTS

Channel --

Frequency (MHz)
910

PSD (dBm)
6.35

Limit (dBm)
8

Margin (dB)
1.65

Result COMPLIANT

Mod 18_48 rev06 Test Report FCCTR

Test report n. FCCTR_185700-0 I Date 26/11/2024

Page 16 di 38

TEST 4.
REFERENCE DOCUMENT

PRS LAB S.r.l. Unipersonale
Sede operativa e Laboratori di prova Headquarter and Testing lab: Via Campagna, 92 I 22020 Faloppio (CO) I Italy Tel. +39 031 3500011 I Fax +39 031 991309 [email protected] I www.primaricerca.it
6dB CHANNEL BANDWIDTH
According to §15,247(a)(2) Systems using digital modulation techniques may operate in the 902-928MHz, 2400-2483.5MHz, and 5725-5850MHz bands, The minimum 6 dB bandwidth shall be at least 500 kHz.

· TEST LOCATION · TYPE OF MEASUREMENT · TEST EQUIPMENT USED FOR TEST
· TESTED PORT · TEST METHOD · FREQUENCY RANGE

Radio test area

Radiated

Instrument Emi Receiver
Antenna

Manufacturer
Rohde & Schwarz

Model ESU 40

Serial n° 100111

Calibrated On Due to

03/2024

03/2025

ANSI C63.10:2020; ANSI C63.10:2020/Cor.1:2023 section 6.9

Carrier

TEST CONDITIONS Ambient temperature Ambient humidity Pressure

REQUIRED 23°C  5°C 25 - 75%rH 85 - 106kPa (860mbar - 1060mbar)

MEASURED 24 °C 45% 960 mbar

OPERATING CONDITION: #1

RESULT: COMPLIANT

Mod 18_48 rev06 Test Report FCCTR

Test report n. FCCTR_185700-0 I Date 26/11/2024

Page 17 di 38

Resolution bandwidth Video bandwidth Span Sweep time Detector Trace-Mode

PRS LAB S.r.l. Unipersonale
Sede operativa e Laboratori di prova Headquarter and Testing lab: Via Campagna, 92 I 22020 Faloppio (CO) I Italy Tel. +39 031 3500011 I Fax +39 031 991309 [email protected] I www.primaricerca.it
MEASUREMENT PARAMETER ­ 6dB Bandwidth 100kHz 300kHz 5MHz Auto couple Peak Max. hold

TEST DESCRIPTION
Allow the trace to stabilize. Measure the maximum width of the emission that is constrained by the frequencies associated with the two outermost amplitude points (upper and lower frequencies) that are attenuated by 6 dB relative to the maximum level measured in the fundamental emission

Mod 18_48 rev06 Test Report FCCTR

Test report n. FCCTR_185700-0 I Date 26/11/2024

Page 18 di 38

Channel --

PRS LAB S.r.l. Unipersonale
Sede operativa e Laboratori di prova Headquarter and Testing lab: Via Campagna, 92 I 22020 Faloppio (CO) I Italy Tel. +39 031 3500011 I Fax +39 031 991309 [email protected] I www.primaricerca.it
Measurement Result

Frequency (MHz)
910

6dB Bandwidth (kHz)
1100

Limits (kHz)
>500

6dB Bandwidth

Verdict Within the limits

Mod 18_48 rev06 Test Report FCCTR

Test report n. FCCTR_185700-0 I Date 26/11/2024

Page 19 di 38

TEST 5.
REFERENCE DOCUMENT

PRS LAB S.r.l. Unipersonale
Sede operativa e Laboratori di prova Headquarter and Testing lab: Via Campagna, 92 I 22020 Faloppio (CO) I Italy Tel. +39 031 3500011 I Fax +39 031 991309 [email protected] I www.primaricerca.it
BAND EDGE
According to §15,247(d) In any 100 kHz bandwidth outside the frequency band in which the spread spectrum or digitally modulated intentional radiator is operating, the radio frequency power that is produced by the intentional radiator shall be at least 20 dB below that in the 100 kHz bandwidth within the band that contains the highest level of the desired power, based on either an RF conducted or a radiated measurement, provided the transmitter demonstrates compliance with the peak conducted power limits, If the transmitter complies with the conducted power limits based on the use of RMS averaging over a time interval, as permitted under paragraph (b)(3) of this section, the attenuation required under this paragraph shall be 30 dB instead of 20 dB, Attenuation below the general limits specified in Sec, 15,209(a) is not required, In addition, radiated emissions which fall in the restricted bands, as defined in Sec, 15,205(a), must also comply with the radiated emission limits specified in Sec, 15,209(a) (see Sec, 15,205(c)),

· TEST LOCATION · TYPE OF MEASUREMENT · TEST EQUIPMENT USED FOR TEST
· TESTED PORT · TEST METHOD · FREQUENCY RANGE

Radio test area

Conducted

Instrument Emi Receiver
Antenna

Manufacturer
Rohde & Schwarz

Model ESU 40

Serial n° 100111

Calibrated On Due to

03/2024

03/2025

ANSI C63.10:2020; ANSI C63.10:2020/Cor.1:2023 section 11.13

Carrier

TEST CONDITIONS Ambient temperature Ambient humidity Pressure

REQUIRED 23°C  5°C 25 - 75%rH 86 - 106kPa (860mbar - 1060mbar)

MEASURED 24 °C 45% 1014 mbar

OPERATING CONDITION: #1

RESULT: COMPLIANT

Mod 18_48 rev06 Test Report FCCTR

Test report n. FCCTR_185700-0 I Date 26/11/2024

Page 20 di 38

PRS LAB S.r.l. Unipersonale
Sede operativa e Laboratori di prova Headquarter and Testing lab: Via Campagna, 92 I 22020 Faloppio (CO) I Italy Tel. +39 031 3500011 I Fax +39 031 991309 [email protected] I www.primaricerca.it
TEST RESULTS
CHANNEL -910 MHZ

Mod 18_48 rev06 Test Report FCCTR

Test report n. FCCTR_185700-0 I Date 26/11/2024

Page 21 di 38

TEST 6.
REFERENCE DOCUMENT

PRS LAB S.r.l. Unipersonale
Sede operativa e Laboratori di prova Headquarter and Testing lab: Via Campagna, 92 I 22020 Faloppio (CO) I Italy Tel. +39 031 3500011 I Fax +39 031 991309 [email protected] I www.primaricerca.it
RF RADIATED SPURIOUS EMISSIONS AT THE TRANSMITTER ANTENNA TERMINAL
According to $ 15.247 (d) and $ 15.209 (a) In any 100 kHz bandwidth outside the frequency band in which the spread spectrum or digitally modulated intentional radiator is operating, the radio frequency power that is produced by the intentional radiator shall be at least 20 Db below that in the 100 kHz bandwidth within the band that contains the highest level of the desired power, based on either an RF conducted or a radiated measurement, provided the transmitter demonstrates compliance with the peak conducted power limits. If the transmitter complies with the conducted power limits based on the use of RMS averaging over a time interval, as permitted under paragraph (b)(3) of this section, the attenuation required under this paragraph shall be 30 Db instead of 20 Db. Attenuation below the general limits specified in §15.209(a) is not required. In addition, radiated emissions which fall in the restricted bands, as defined in §15.205(a), must also comply with the radiated emission limits specified in §15.209(a) (see §15.205(c)).

· TEST LOCATION · TYPE OF MEASUREMENT · TEST EQUIPMENT USED FOR TEST
· TESTED PORT · TEST METHOD · FREQUENCY RANGE · LIMITS

Radio test area

Conducted

Instrument Emi Receiver
Antenna

Manufacturer
Rohde & Schwarz

Model ESU 40

Serial n° 100111

Calibrated On Due to

03/2024

03/2025

ANSI C63.10:2020; ANSI C63.10:2020/Cor.1:2023 section 7.8.8

30MHz ­ 26GHz

Acc. To ref. Std.

TEST CONDITIONS Ambient temperature Ambient humidity Pressure

REQUIRED 23°C  5°C 25 - 75%rH 86 - 106kPa (860mbar - 1060mbar)

MEASURED 24 °C 45% 1014 mbar

OPERATING CONDITION: #1

RESULT: WITHIN THE LIMITS

Mod 18_48 rev06 Test Report FCCTR

Test report n. FCCTR_185700-0 I Date 26/11/2024

Page 22 di 38

PRS LAB S.r.l. Unipersonale
Sede operativa e Laboratori di prova Headquarter and Testing lab: Via Campagna, 92 I 22020 Faloppio (CO) I Italy Tel. +39 031 3500011 I Fax +39 031 991309 [email protected] I www.primaricerca.it
TEST RESULTS

Frequency range: 30MHz ­ 1GHz

Channel 910MHz

Frequency range: 1GHz ­ 26GHz

Mod 18_48 rev06 Test Report FCCTR

Test report n. FCCTR_185700-0 I Date 26/11/2024

Page 23 di 38

TEST 7.
REFERENCE DOCUMENT

PRS LAB S.r.l. Unipersonale
Sede operativa e Laboratori di prova Headquarter and Testing lab: Via Campagna, 92 I 22020 Faloppio (CO) I Italy Tel. +39 031 3500011 I Fax +39 031 991309 [email protected] I www.primaricerca.it
TRANSMITTER RADIATED EMISSIONS < 1GHZ
According to $ 15.247 (d) and $ 15.209 (a) In any 100 kHz bandwidth outside the frequency band in which the spread spectrum or digitally modulated intentional radiator is operating, the radio frequency power that is produced by the intentional radiator shall be at least 20 Db below that in the 100 kHz bandwidth within the band that contains the highest level of the desired power, based on either an RF conducted or a radiated measurement, provided the transmitter demonstrates compliance with the peak conducted power limits. If the transmitter complies with the conducted power limits based on the use of RMS averaging over a time interval, as permitted under paragraph (b)(3) of this section, the attenuation required under this paragraph shall be 30 Db instead of 20 Db. Attenuation below the general limits specified in §15.209(a) is not required. In addition, radiated emissions which fall in the restricted bands, as defined in §15.205(a), must also comply with the radiated emission limits specified in §15.209(a) (see §15.205(c)).

· TEST LOCATION · DISTANCE OF MEASUREMENT · TYPE OF MEASUREMENT · TEST EQUIPMENT USED FOR TEST
· TESTED PORT · TEST METHOD · FREQUENCY RANGE · LIMITS · UNCERTAINTY OF MEASURE

Semi-Anechoic Chamber

3m

Radiated

Instrument Manufacturer

Emi Receiver

Rohde & Schwarz

MXE Emi Receiver

Keysight

Semi-Anechoic Chamber

Siemens

Loop antenna

Rohde & Schwarz

Bi-log antenna Chase

Software EMC

Rohde & Schwarz

Enclosure

Model ESU 40
N9038A B83117D6019-T232 HFH 2-Z2 CBL6111C EMC32-E

Serial n° 100111

Calibrated On Due to

03/2024

03/2025

MY57290150 003-005134/94C 841801/012 2717 V 8.40.0

11/2023

11/2024

02/2024

02/2025

03/2023

03/2026

03/2022

03/2025

N.A.

ANSI C63.10:2020; ANSI C63.10:2020/Cor.1:2023 section 6.5

9kHz ­ 1GHz

Acc. To ref. Std.

Level of confidence = 95% (k=2) Expanded uncertainty 9kHz ­ 30MHz = 4,24 dB Expanded uncertainty 30MHz ­ 1GHz = 5,72 dB

TEST CONDITIONS Ambient temperature Ambient humidity Pressure
OPERATING CONDITION: #1
RESULT: WITHIN THE LIMITS
Mod 18_48 rev06 Test Report FCCTR

REQUIRED 23°C  5°C 25 - 75%rH 86 - 106kPa (860mbar - 1060mbar)
Test report n. FCCTR_185700-0 I Date 26/11/2024

MEASURED 24 °C 45% 1014 mbar
Page 24 di 38

Frequency Range: Resolution bandwidth: Video bandwidth: Span: Sweep time Detector: Trace-Mode:

PRS LAB S.r.l. Unipersonale
Sede operativa e Laboratori di prova Headquarter and Testing lab: Via Campagna, 92 I 22020 Faloppio (CO) I Italy Tel. +39 031 3500011 I Fax +39 031 991309 [email protected] I www.primaricerca.it
MEASUREMENT PARAMETER 9kHz ­ 30MHz
200Hz 1kHz See plots below Auto couple Peak Max. hold

30MHz ­ 1GHz 100kHz 300kHz
See plots below Auto couple Peak Max. hold

TEST DESCRIPTION
Measurement is made at a semi-anechoic chamber that incorporates a turntable allowing a EUT rotation of 360°. A continuously - rotating, remotely - controlled turntable is installed at the test site to support the EUT and facilitate determination of the direction of maximum radiation for each EUT emission frequency.
The EUT is placed at test table height is 80 cm above the reference ground plane.
Measurement is made with the antenna positioned in both the horizontal and vertical planes of polarization. The measurement antenna is varied in height (1m~4m) above the reference ground plane to obtain the maximum signal strength. Distance between EUT and antenna is 3m.
This investigation is performed with the EUT rotated 360°, the antenna height scanned between 1 m and 4 m, and the antenna rotated to repeat the measurements for both the horizontal and vertical antenna polarizations.

TEST SETUP BLOCK DIAGRAM SEMI ANECHOIC CHAMBER

EMI RECEIVER

EUT

Mod 18_48 rev06 Test Report FCCTR

Test report n. FCCTR_185700-0 I Date 26/11/2024

Page 25 di 38

PRS LAB S.r.l. Unipersonale
Sede operativa e Laboratori di prova Headquarter and Testing lab: Via Campagna, 92 I 22020 Faloppio (CO) I Italy Tel. +39 031 3500011 I Fax +39 031 991309 [email protected] I www.primaricerca.it
TEST RESULTS - Radiated with antenna SRFI068H-100

RX Antenna Polarization: ---

Carrier frequency 910MHz Frequency Range: 9kHz ­ 30MHz

130 120

100

Level in dBµV/m

80
FCC_R SS _GEN _low _30MH z_3m
60

40

20

0

-20 9k

20 30

FCC_R SS _GEN _low _30MH z_3m

50

100k

200 300 500

1M

Frequency in Hz

MaxP eak -ClearW rite-P K+

2M 3M 5M

10M

20 30M

Final Result: All emissions are below 10dB from the limit, for this reason no further assessments were carried out on the individual points

Mod 18_48 rev06 Test Report FCCTR

Test report n. FCCTR_185700-0 I Date 26/11/2024

Page 26 di 38

PRS LAB S.r.l. Unipersonale
Sede operativa e Laboratori di prova Headquarter and Testing lab: Via Campagna, 92 I 22020 Faloppio (CO) I Italy Tel. +39 031 3500011 I Fax +39 031 991309 [email protected] I www.primaricerca.it

RX Antenna Polarization: Vertical

Frequency Range: 30MHz ­ 1GHz

Emissio ne R adiata _FCC_Spu rie

Level in dBµV/m

10 0 90 80 70 60 50 40 30 20 10 0 -10 30 M

50 60

80 100M

20 0
Frequency in Hz

300 400 500

800 1G

Final Result:

Frequency (MHz)
875.640000 909.780000 910.230000

QuasiPeak (dBµV/m)
34.8 94.9 94.7

Height (cm)
257.8 231.8 232.8

Azimuth (deg)
7.0 82.0 82.0

Margin (dB)
11.60 -48.50 -48.30

Limit (dBµV/m)
46.40 46.40 46.40

Frequency (MHz)
879.120000 909.750000 910.230000

Average (dBµV/m)
23.3 89.2 89.2

Height (cm)
330.1 203.8 205.8

Azimuth (deg)
7.0 82.0 82.0

Margin (dB)
23.10 -42.80 -42.80

Limit (dBµV/m)
46.40 46.40 46.40

NOTE: Peaks out of limits are due to carrier frequency.

Mod 18_48 rev06 Test Report FCCTR

Test report n. FCCTR_185700-0 I Date 26/11/2024

Page 27 di 38

PRS LAB S.r.l. Unipersonale
Sede operativa e Laboratori di prova Headquarter and Testing lab: Via Campagna, 92 I 22020 Faloppio (CO) I Italy Tel. +39 031 3500011 I Fax +39 031 991309 [email protected] I www.primaricerca.it

RX Antenna Polarization: Horizontal

Frequency Range: 30MHz ­ 1GHz

Emissio ne R adiata _FCC_Spu rie

Level in dBµV/m

10 0 90 80 70 60 50 40 30 20 10 0 -10 30 M

50 60

80 100M

20 0
Frequency in Hz

300 400 500

800 1G

Final Result:

Frequency (MHz)
716.760000 909.780000 910.230000

QuasiPeak (dBµV/m)
27.7 97.8 97.6

Height (cm)
99.7 99.8 99.7

Azimuth (deg)
172.0 -5.0 -5.0

Margin (dB)
18.70 -51.40 -51.20

Limit (dBµV/m)
46.40 46.40 46.40

Frequency (MHz)
717.420000 909.750000 910.230000

Average (dBµV/m)
21.7 91.9 91.6

Height (cm)
99.8 99.8 99.8

Azimuth (deg)
183.0 0.0 3.0

Margin (dB)
24.70 -45.50 -45.20

Limit (dBµV/m)
46.40 46.40 46.40

NOTE: Peaks out of limits are due to carrier frequency.

Mod 18_48 rev06 Test Report FCCTR

Test report n. FCCTR_185700-0 I Date 26/11/2024

Page 28 di 38

PRS LAB S.r.l. Unipersonale
Sede operativa e Laboratori di prova Headquarter and Testing lab: Via Campagna, 92 I 22020 Faloppio (CO) I Italy Tel. +39 031 3500011 I Fax +39 031 991309 [email protected] I www.primaricerca.it
TEST RESULTS - Radiated with antenna SRFI068V-100

RX Antenna Polarization: ---

Carrier frequency 910MHz Frequency Range: 9kHz ­ 30MHz

130 120

100

Level in dBµV/m

80
FCC_R S S_GEN _low _30M H z_3 m
60

40

20

0

-20 9k

20 30

FCC_R S S_GEN _low _30M H z_3 m

50

100k

200 300 500

1M

Frequency in Hz

MaxP eak -ClearW rite-P K+

2M 3M 5M

10M

20 30M

Final Result: All emissions are below 10dB from the limit, for this reason no further assessments were carried out on the individual points

Mod 18_48 rev06 Test Report FCCTR

Test report n. FCCTR_185700-0 I Date 26/11/2024

Page 29 di 38

PRS LAB S.r.l. Unipersonale
Sede operativa e Laboratori di prova Headquarter and Testing lab: Via Campagna, 92 I 22020 Faloppio (CO) I Italy Tel. +39 031 3500011 I Fax +39 031 991309 [email protected] I www.primaricerca.it

RX Antenna Polarization: Vertical

Frequency Range: 30MHz ­ 1GHz

Emissio ne R adiata _FCC_Spu rie

Level in dBµV/m

10 0 90 80 70 60 50 40 30 20 10 0 -10 30 M

50 60

80 100M

20 0
Frequency in Hz

300 400 500

800 1G

Final Result:

Frequency (MHz)
904.590000 909.780000 910.230000

QuasiPeak (dBµV/m)
30.6 99.6 98.6

Height (cm)
312.8 124.8 127.8

Azimuth (deg)
264.0 -8.0 -4.0

Margin (dB)
15.80 -53.20 -52.20

Limit (dBµV/m)
46.40 46.40 46.40

Frequency (MHz)
903.480000 909.750000 910.230000

Average (dBµV/m)
23.8 93.5 93.1

Height (cm)
204.8 123.8 125.8

Azimuth (deg)
277.0 -8.0 -6.0

Margin (dB)
22.60 -47.10 -46.70

Limit (dBµV/m)
46.40 46.40 46.40

NOTE: Peaks out of limits are due to carrier frequency.

Mod 18_48 rev06 Test Report FCCTR

Test report n. FCCTR_185700-0 I Date 26/11/2024

Page 30 di 38

PRS LAB S.r.l. Unipersonale
Sede operativa e Laboratori di prova Headquarter and Testing lab: Via Campagna, 92 I 22020 Faloppio (CO) I Italy Tel. +39 031 3500011 I Fax +39 031 991309 [email protected] I www.primaricerca.it

RX Antenna Polarization: Horizontal

Frequency Range: 30MHz ­ 1GHz

Emissio ne R adiata _FCC_Spu rie

Level in dBµV/m

10 0 90 80 70 60 50 40 30 20 10 0 -10 30 M

50 60

80 100M

20 0
Frequency in Hz

300 400 500

800 1G

Final Result:

Frequency (MHz)
909.780000 910.230000 933.060000

QuasiPeak (dBµV/m)
97.9 97.8 36.8

Height (cm)
99.7 99.8 180.1

Azimuth (deg)
277.0 277.0 277.0

Margin (dB)
-51.50 -51.40
9.60

Limit (dBµV/m)
46.40 46.40 46.40

Frequency (MHz)
909.750000 910.230000 933.360000

Average (dBµV/m)
92.4 91.8 24.4

Height (cm)
104.7 99.8 99.8

Azimuth (deg)
277.0 277.0 277.0

Margin (dB)
-46.00 -45.40 22.00

Limit (dBµV/m)
46.40 46.40 46.40

NOTE: Peaks out of limits are due to carrier frequency.

Mod 18_48 rev06 Test Report FCCTR

Test report n. FCCTR_185700-0 I Date 26/11/2024

Page 31 di 38

PRS LAB S.r.l. Unipersonale
Sede operativa e Laboratori di prova Headquarter and Testing lab: Via Campagna, 92 I 22020 Faloppio (CO) I Italy Tel. +39 031 3500011 I Fax +39 031 991309 [email protected] I www.primaricerca.it

TEST 8.
REFERENCE DOCUMENT
· TEST SETUP · TEST LOCATION · DISTANCE OF MEASUREMENT · TYPE OF MEASUREMENT · TEST EQUIPMENT USED FOR TEST
· TESTED PORT · TEST METHOD · FREQUENCY RANGE · LIMITS · UNCERTAINTY OF MEASURE
TEST CONDITIONS Ambient temperature Ambient humidity Pressure
OPERATING CONDITION: #1

TRANSMITTER RADIATED EMISSIONS > 1GHZ

According to $ 15.247 (d) and $ 15.209 (a)
In any 100 kHz bandwidth outside the frequency band in which the spread spectrum or digitally modulated intentional radiator is operating, the radio frequency power that is produced by the intentional radiator shall be at least 20 Db below that in the 100 kHz bandwidth within the band that contains the highest level of the desired power, based on either an RF conducted or a radiated measurement, provided the transmitter demonstrates compliance with the peak conducted power limits. If the transmitter complies with the conducted power limits based on the use of RMS averaging over a time interval, as permitted under paragraph (b)(3) of this section, the attenuation required under this paragraph shall be 30 Db instead of 20 Db. Attenuation below the general limits specified in §15.209(a) is not required. In addition, radiated emissions which fall in the restricted bands, as defined in §15.205(a), must also comply with the radiated emission limits specified in §15.209(a) (see §15.205(c)).

Acc. To ref. Std.

Semi-Anechoic Chamber

3m

Radiated

Instrument Manufacturer Model

MXE Emi Receiver

Keysight

N9038A

Semi-Anechoic Chamber

Siemens

B83117D6019-T232

Horn antenna Electro Metrics EM-6961

High pass filter Waineright WHK 1,3/15G

Software EMC

Rohde & Schwarz

EMC32-E

Antenna

Serial n°
MY57290150
003-005134/94C 100437 9
V 8.40.0

Calibrated On Due to

11/2023

11/2024

02/2024

02/2025

10/2023 10/2023

10/2026 10/2025

N.A.

ANSI C63.10:2020; ANSI C63.10:2020/Cor.1:2023 section 6.6

1GHz ­ 10GHz

Acc. To ref. Std.

Level of confidence = 95% (k=2) Expanded uncertainty 1GHz ­ 10GHz = 5,15 dB

REQUIRED 23°C  5°C 25 - 75%rH 86 - 106kPa (860mbar - 1060mbar)

MEASURED 24 °C 45% 1014 mbar

RESULT: WITHIN THE LIMITS

Mod 18_48 rev06 Test Report FCCTR

Test report n. FCCTR_185700-0 I Date 26/11/2024

Page 32 di 38

Resolution bandwidth: Video bandwidth: Span: Sweep time Detector: Trace-Mode:

PRS LAB S.r.l. Unipersonale
Sede operativa e Laboratori di prova Headquarter and Testing lab: Via Campagna, 92 I 22020 Faloppio (CO) I Italy Tel. +39 031 3500011 I Fax +39 031 991309 [email protected] I www.primaricerca.it
MEASUREMENT PARAMETER 1GHz - 10GHz
1MHz
3MHz
See plots below
Auto couple
Peak
Max. hold

TEST DESCRIPTION
Measurement is made at a semi-anechoic chamber that incorporates a turntable allowing a EUT rotation of 360°. A continuously - rotating, remotely - controlled turntable is installed at the test site to support the EUT and facilitate determination of the direction of maximum radiation for each EUT emission frequency.
The EUT is placed at test table height is 1.5 m
Measurement is made with the antenna positioned in both the horizontal and vertical planes of polarization. The measurement antenna is varied in height (1m~4m) above the reference ground plane to obtain the maximum signal strength. Distance between EUT and antenna is 3m.
This investigation is performed with the EUT rotated 360°, the antenna height scanned between 1 m and 4 m, and the antenna rotated to repeat the measurements for both the horizontal and vertical antenna polarizations.

TEST SETUP BLOCK DIAGRAM SEMI ANECHOIC CHAMBER

EMI RECEIVER

EUT

Mod 18_48 rev06 Test Report FCCTR

Test report n. FCCTR_185700-0 I Date 26/11/2024

Page 33 di 38

PRS LAB S.r.l. Unipersonale
Sede operativa e Laboratori di prova Headquarter and Testing lab: Via Campagna, 92 I 22020 Faloppio (CO) I Italy Tel. +39 031 3500011 I Fax +39 031 991309 [email protected] I www.primaricerca.it
TEST RESULTS - Radiated with antenna SRFI068H-100

Carrier frequency 910MHz

RX Antenna Polarization: Vertical

Frequency Range: 1GHz ­ 10GHz

Emissio ne R adiata _FCC

80

70

60

Level in dBµV/m

50

40

30

20

10

0

1G

2G

3G

4G

5G

6

7 8 9 10G

Frequency in Hz

Final Result:

Mod 18_48 rev06 Test Report FCCTR

Test report n. FCCTR_185700-0 I Date 26/11/2024

Page 34 di 38

PRS LAB S.r.l. Unipersonale
Sede operativa e Laboratori di prova Headquarter and Testing lab: Via Campagna, 92 I 22020 Faloppio (CO) I Italy Tel. +39 031 3500011 I Fax +39 031 991309 [email protected] I www.primaricerca.it

RX Antenna Polarization: Horizontal

Emissio ne R adiata _FCC

Frequency Range: 1GHz ­ 10GHz

80

70

60

Level in dBµV/m

50

40

30

20

10

0

1G

2G

3G

4G

5G

6

7 8 9 10G

Frequency in Hz

Final Result:

Mod 18_48 rev06 Test Report FCCTR

Test report n. FCCTR_185700-0 I Date 26/11/2024

Page 35 di 38

PRS LAB S.r.l. Unipersonale
Sede operativa e Laboratori di prova Headquarter and Testing lab: Via Campagna, 92 I 22020 Faloppio (CO) I Italy Tel. +39 031 3500011 I Fax +39 031 991309 [email protected] I www.primaricerca.it
TEST RESULTS - Radiated with antenna SRFI068V-100

Carrier frequency 910MHz

RX Antenna Polarization: Vertical

Frequency Range: 1GHz ­ 10GHz

Emissio ne R adiata _FCC

80

70

60

Level in dBµV/m

50

40

30

20

10

0

1G

2G

3G

4G

5G

6

7 8 9 10G

Frequency in Hz

Final Result:

Mod 18_48 rev06 Test Report FCCTR

Test report n. FCCTR_185700-0 I Date 26/11/2024

Page 36 di 38

PRS LAB S.r.l. Unipersonale
Sede operativa e Laboratori di prova Headquarter and Testing lab: Via Campagna, 92 I 22020 Faloppio (CO) I Italy Tel. +39 031 3500011 I Fax +39 031 991309 [email protected] I www.primaricerca.it

RX Antenna Polarization: Horizontal

Emissio ne R adiata _FCC

Frequency Range: 1GHz ­ 10GHz

80

70

60

Level in dBµV/m

50

40

30

20

10

0

1G

2G

3G

4G

5G

6

7 8 9 10G

Frequency in Hz

Final Result:

Mod 18_48 rev06 Test Report FCCTR

Test report n. FCCTR_185700-0 I Date 26/11/2024

Page 37 di 38

PRS LAB S.r.l. Unipersonale
Sede operativa e Laboratori di prova Headquarter and Testing lab: Via Campagna, 92 I 22020 Faloppio (CO) I Italy Tel. +39 031 3500011 I Fax +39 031 991309 [email protected] I www.primaricerca.it
END OF TEST REPORT

Mod 18_48 rev06 Test Report FCCTR

Test report n. FCCTR_185700-0 I Date 26/11/2024

Page 38 di 38



Related FCC IDs:

Search Any Device: