Test Report

Report No.: OP20241211

Antenna Gain Test Report

EquipmentWatch Brand NameONEPLUS Model NameOPWE242 Manufacturer Guangdong OPPO Mobile Telecommunications Corp., Ltd. NO.18 Haibin Road, Wusha Village, Chang'an Town, Dongguan City, Guangdong, China Issue DateDecember 11th, 2024

Project Engineer:Huiqing Sun Date:2024/12/11 Checked by: Changhong Tang Date: 2024/12/11 Approved by: Tianping Liang Date:2024/12/11

Test Report

Report No.: OP20241211

Antenna Gain and Antenna Type specification:

Band

2.4G WIFI 2400~2483.5MHz

5150~5250 MHz

5250~5350 MHz

5G WIFI

5470~5725 MHz

5725~5850 MHz

BT

2400~2483.5MHz

Ant Ant1 Ant1 Ant1 Ant1 Ant1 Ant1

Antenna Gain (dBi)
-3.5 -0.5 -0.5 -0.5 -0.5 -3.5

Antenna model
AC181-TOPCOVER
AC181-TOPCOVER
AC181-TOPCOVER
AC181-TOPCOVER
AC181-TOPCOVER
AC181-TOPCOVER

Antenna Type Manufacturer

Monopole antenna Monopole antenna Monopole antenna Monopole antenna Monopole antenna Monopole antenna

Everwin Precision Technology Co., Ltd

Table1 Antenna Gain and Antenna Type specification

Note: Antenna gain was measured in the anechoic chamber, 3D scan was exercised, and the highest numbers are reported in this document. According to Test standard: IEEE Std 149-2021, we measure antenna gain.
Antenna Radiation Pattern:
2.4G&5G WIFI2.4G/BT
WIFI5G B1 5150~5250 MHz

Test Report
WIFI5G B2 5250~5350 MHz

Report No.: OP20241211

WIFI5G B3 5470~5725 MHz

WIFI5G B4 5725~5850 MHz

List of Test and Measurement Instruments

TEST EQUIPMENT

NO. Equipment Manufacturer Model No.

1

AMS-8923

ETS-Lingen

SN1702

Network

2

Analyzer

Keysight

MY4690575

E5071C

Cal date 2024/12/11 2024/12/11

Test Software
EMQuest

Test Report

Report No.: OP20241211

I. Measurement Setup:
A. Reflection Coefficient Measurement:
Instrument: Network Analyzer (Keysight E5071C). Setup: 1. Calibrate the Network Analyzer by one port calibration using Keysight 85093C Electronic calibration module. 2. Connect the antenna under test to the Network Analyzer. 3. Measure the S11(reflection coefficient), Return Loss....
B. Pattern Measurement:
A Fully Anechoic Chamber is used to simulate free-space conditions. A Fully Anechoic Chamber is a shielded room lined with RF/microwave absorber on all walls, ceiling, and floor.

RF/microwave absorber reduces reflections from the inner walls of the shield. Absorber performance depends on the depth and design of the absorber and the angle of incidence of the field.

Normal incidence is best, shallower angles are worse.

Fig. 4. The fully anechoic chamber

