R0403232 Base Rpt

annie

Test Report

Continental Conair Limited GH3100 Cordless Phone LBBGH3100 LBBGH3100 gh3100

PDF Viewing Options

Not Your Device? Search For Manuals or Datasheets below:


File Info : application/pdf, 24 Pages, 638.63KB

Document DEVICE REPORTGetApplicationAttachment.html?id=424120
FCC PART 15 Subpart C
EMI MEASUREMENT AND TEST REPORT
For
Continental Conair Limited
35/F Standard Chartered Tower Millennium City, 388 Kwun Tong Road
Kwun Tong, Kowloon, HK

FCC ID: LBBGH3100

2004-04-22

This Report Concerns: Original Report

Equipment Type: 2.4GHz Cordless Phone

Test Engineer: Ling Zhang/ Report No.: R0403232(Base) Test Date: 2004-04-08

Reviewed By: Hans Mellberg/

Prepared By:

Bay Area Compliance Laboratory Corporation 230 Commercial Street Sunnyvale, CA 94085 Tel (408) 732-9162 Fax (408) 732-9164

Note: This test report is specially limited to the above client company and the product model only. It may not be duplicated without prior written consent of Bay Area Compliance Laboratory Corporation. This report must not be used by the client to claim product endorsement by NVLAP or any agency of the U.S. Government.

Continental Conair Limited

FCC ID: LBBGH3100

TABLE OF CONTENTS
GENERAL INFORMATION.......................................................................................................................................3
PRODUCT DESCRIPTION FOR EQUIPMENT UNDER TEST (EUT) ....................................................................................3 OBJECTIVE ...................................................................................................................................................................3 RELATED SUBMITTAL(S)/GRANT(S).............................................................................................................................3 TEST METHODOLOGY ..................................................................................................................................................3 TEST FACILITY.............................................................................................................................................................3
SYSTEM TEST CONFIGURATION..........................................................................................................................5
DESCRIPTION OF TEST CONFIGURATION ......................................................................................................................5 EQUIPMENT MODIFICATIONS .......................................................................................................................................5 CONFIGURATION OF TEST SYSTEM ..............................................................................................................................5 TEST SETUP BLOCK DIAGRAM .....................................................................................................................................5 LOCAL SUPPORT EQUIPMENT LIST AND DETAILS ........................................................................................................6 EXTERNAL I/O CABLING LIST AND DETAILS ...............................................................................................................6
SUMMARY OF TEST RESULTS ...............................................................................................................................7
§ 15.207 - CONDUCTED EMISSIONS TEST DATA................................................................................................8
MEASUREMENT UNCERTAINTY....................................................................................................................................8 EUT SETUP..................................................................................................................................................................8 SPECTRUM ANALYZER SETUP ......................................................................................................................................8 TEST EQUIPMENT LIST AND DETAILS...........................................................................................................................8 TEST PROCEDURE ........................................................................................................................................................8 ENVIRONMENTAL CONDITIONS....................................................................................................................................9 SUMMARY OF TEST RESULTS .......................................................................................................................................9 CONDUCTED EMISSIONS TEST DATA (MODEL: GH3150) ............................................................................................9 CONDUCTED EMISSIONS TEST DATA (MODEL: GH3110 & GH3100)........................................................................10 PLOT OF CONDUCTED EMISSIONS TEST DATA ...........................................................................................................10
§15.209(A), §15.205 & §15.249 - RADIATED EMISSION DATA ..........................................................................17
MEASUREMENT UNCERTAINTY..................................................................................................................................17 EUT SETUP................................................................................................................................................................17 SPECTRUM ANALYZER SETUP ....................................................................................................................................17 TEST EQUIPMENT LIST AND DETAILS.........................................................................................................................17 ENVIRONMENTAL CONDITIONS..................................................................................................................................18 TEST PROCEDURE ......................................................................................................................................................18 CORRECTED AMPLITUDE & MARGIN CALCULATION .................................................................................................18 SUMMARY OF TEST RESULTS .....................................................................................................................................18 RADIATED EMISSIONS TEST RESULT DATA ...............................................................................................................19
§15.249(C) ­ BAND-EDGE TESTING ......................................................................................................................21
STANDARD APPLICABLE ............................................................................................................................................21 TEST PROCEDURE ......................................................................................................................................................21 TEST EQUIPMENT LIST AND DETAILS.........................................................................................................................21 ENVIRONMENTAL CONDITIONS..................................................................................................................................21 TEST RESULTS ...........................................................................................................................................................21

Report # R0403232(Base)Rpt

Page 2 of 24

FCC Part 15.249 Test Report

Continental Conair Limited

FCC ID: LBBGH3100

GENERAL INFORMATION
Product Description for Equipment Under Test (EUT)
The Continental Conair Limited's product, model name: GH3150(XXXXX), GH3110(XXXXX), GH301WCS and GH3100(XXXXX) where `X' may be some alphabet representing color code and packing information, the "EUT" as referred to in this report are Base, 2.4GHz Cordless Phone. The EUT was composed of two parts, one is a Handset and the other is a Base. This report is for Base only.
GH3150(XXXXX) which measures approximately 180mmL x 55mmW x 40mmH. GH3110(XXXXX) which measures approximately 122mmL x 122mmW x 110mmH. GH3100(XXXXX) which measures approximately 122mmL x 122mmW x 110mmH.
GH3150(XXXXX) and GH3110(XXXXX)'s base are identical in construction, dimensions, and electrical circuits. The main modification for GH3110(XXXXX) is the removal of additional answer machine feature, Base Main PCB and Base unit were changed and some components were removed on the base unit.
GH3100(XXXXX) and GH3110(XXXXX)'s base are identical in all design.
* The test data gathered are from production sample, serial number: GH3150OR1/GH3110R1/GH3100R1, provided by the manufacturer.

Objective
This document is a test report based on the Electromagnetic Interference (EMI) tests performed on the EUT. The EMI measurements were performed according to the measurement procedure described in ANSI C63.4 - 2001.
The tests were performed in order to determine compliance with FCC Part 15, Subpart C, section 15.205, 15.207, 15.249, 15.203 and 15.209 rules.

Related Submittal(s)/Grant(s)
No Related Submittals

Test Methodology
All measurements contained in this report were conducted with ANSI C63.4 - 2001, American National Standard for Methods of Measurement of Radio-Noise Emissions from Low-Voltage Electrical and Electronic Equipment in the range of 9 kHz to 40 GHz. All radiated and conducted emissions measurement was performed at Bay Area Compliance Laboratory, Corp.

Test Facility
The Open Area Test site used by Bay Area Compliance Laboratory Corporation to collect radiated and conducted emission measurement data is located in the back parking lot of the building at 230 Commercial Street, Sunnyvale, California, USA.

Report # R0403232(Base)Rpt

Page 3 of 24

FCC Part 15.249 Test Report

Continental Conair Limited

FCC ID: LBBGH3100

Test site at Bay Area Compliance Laboratory Corporation has been fully described in reports submitted to the Federal Communication Commission (FCC) and Voluntary Control Council for Interference (VCCI). The details of these reports has been found to be in compliance with the requirements of Section 2.948 of the FCC Rules and Article 8 of the VCCI regulations. The facility also complies with the test methods and procedures set forth in ANSI C63.4-2001.
The Federal Communications Commission and Voluntary Control Council for Interference has the reports on file and is listed under FCC file 31040/SIT 1300F2 and VCCI Registration No.: C-1298 and R-1234. The test site has been approved by the FCC and VCCI for public use and is listed in the FCC Public Access Link (PAL) database.
Additionally, Bay Area Compliance Laboratory Corporation is a National Institute of Standards and Technology (NIST) accredited laboratory, under the National Voluntary Laboratory Accredited Program (NVLAP). The scope of the accreditation covers the FCC Method - 47 CFR Part 15 - Digital Devices, CISPR 22:1997 and AS/NZS 3548: Electromagnetic Interference - Limits and Methods of Measurement of Information Technology Equipment test methods under NVLAP Lab Code 200167-0.

Report # R0403232(Base)Rpt

Page 4 of 24

FCC Part 15.249 Test Report

Continental Conair Limited

FCC ID: LBBGH3100

SYSTEM TEST CONFIGURATION
Description of Test Configuration
The EUT was configured for testing according to ANSI C63.4-2001.
Base being tested: The Base unit was placed on the wooden table. The Low, and high channels were tested. The base was connected to the line simulator and an AC adapter via its Tel Line and power ports, respectively. The base was transmitting and receiving from the Handset. The conducted as well as radiated data was taken in this mode of operation. All initial and final investigations were performed with the EMI receiver in manual mode scanning the frequency range continuously. The cables were bundled and routed as shown in the section of configuration of test system.

Equipment Modifications
No modifications were made to the EUT.

Configuration of Test System
Setup for Base

Telephone

Simulator

EUT/Base

Test Setup Block Diagram

LISN 1

EUT Power Cords

Peripheral Power Cords

LISN 2

Telephone

Simulator

EUT/BASE
1 Meter
Non-Conducting Table 80 cm Above Ground Plane

1.5 Meters
Report # R0403232(Base)Rpt

Page 5 of 24

FCC Part 15.249 Test Report

Continental Conair Limited

Local Support Equipment List and Details

Manufacturer Southern Telecom
Teltone Corp

Description Telephone
Simulator

Model None
TLS-3B-01

Serial Number None
80071

FCC ID: LBBGH3100
FCC ID None None

External I/O Cabling List and Details

Cable Description None-Shielded RJ-11 Cable None-Shielded RJ-11 Cable

Length (M) 1.5 1.5

Port/From RJ-11 Port/EUT Support telephone

To Simulator RJ11Port Simulator RJ11Port

Power Supply
Manufacturer Southwestern Bell

Description AC Adaptor

Model DU41090045C

Serial Number None

FCC ID None

Report # R0403232(Base)Rpt

Page 6 of 24

FCC Part 15.249 Test Report

Continental Conair Limited
SUMMARY OF TEST RESULTS

FCC RULES
§15.207 (a) §15.249 (a) §15.249 (c)
§15.203 §15.205 §15.214

DESCRIPTION OF TEST
Conducted Emission Radiated Emission Band Edge Testing Antenna Requirement Restricted Band of Operation Cordless Telephone

FCC ID: LBBGH3100
RESULT Compliant Compliant Compliant Compliant Compliant Compliant

Report # R0403232(Base)Rpt

Page 7 of 24

FCC Part 15.249 Test Report

Continental Conair Limited

FCC ID: LBBGH3100

§ 15.207 - CONDUCTED EMISSIONS TEST DATA
Measurement Uncertainty
All measurements involve certain levels of uncertainties. These uncertainties are attributed to: Spectrum analyzer, Cable loss, and LISN.
Based on NIS 81, The Treatment of Uncertainty in EMC Measurements, the estimated uncertainty of any conducted emission measurement at BACL is +2.4 dB.

EUT Setup
The measurement was performed in the shielded room, using the same setup per ANSI C63.4-2001 measurement procedure. The specification used was FCC 15 Subpart C limits. The spacing between the peripherals was 10 centimeters. External I/O cables were draped along the edge of the test table and bundle as required. The Power Adapter system was connected with 120Vac/60Hz power source.

Spectrum Analyzer Setup
The spectrum analyzer was set to investigate the spectrum from 150 kHz to 30MHz.

Test Equipment List and Details

Manufacturer Description

Rohde & Schwarz

Artificial LISN

Rohde & Schwarz

EMI Test Receiver

Fluke

Calibrated Voltmeter

Model ESH2-Z5
ESCS30 189

Serial Number 871884/039
100176 18485-38

Cal. Date 2004-03-28
2004-05-06 2003-07-18

* Statement of Traceability: BACL Corp. certifies that all calibrations have been performed in accordance to NVLAP requirements, traceable to the NIST.

Test Procedure
During the conducted emission test, the power cord of the host system was connected to the mains outlet of the LISN-1.
Maximizing procedure were performed on the six (6) highest emissions of the EUT.
All data was recorded in the peak detection mode, quasi-peak and average. Qusi-Peak readings are distinguished with an "QP". Average readings are distinguished with an "Ave".

Report # R0403232(Base)Rpt

Page 8 of 24

FCC Part 15.249 Test Report

Continental Conair Limited

Environmental Conditions

Temperature: Relative Humidity: ATM Pressure:

15°C 78% 1016 mbar

FCC ID: LBBGH3100

Summary of Test Results
According to the recorded data in following table, the EUT complies with the FCC Conducted limit for a Class B device, with the worst margin reading of: Model: GH3150 -20.9 dB at 17.9 MHz in the Neutral mode Model: GH3110 & GH3100 -34.2 dB at 4.10 MHz in the Line mode

Conducted Emissions Test Data (Model: GH3150)

Frequency MHz
17.9 17.9 4.1 17.9 4.1 17.9 0.62 4.1 16.2 4.1 16.2 0.62

LINE CONDUCTED EMISSIONS

Amplitude

Detector

dBµV

Qp/Ave/Peak

29.1

AVG

28.5

AVG

16.2

AVG

29.6

QP

14.1

AVG

27.6

QP

16.4

QP

16.3

QP

19.4

QP

14.0

QP

7.9

AVG

3.2

AVG

Phase Line/Neutral
Neutral Line Line
Neutral Neutral
Line Neutral
Line Line Neutral Line Neutral

FCC CLASS B

Limit

Margin

dBµV

dB

50

-20.9

50

-21.5

46

-29.8

60

-30.4

46

-31.9

60

-32.4

56

-39.6

56

-39.7

60

-40.6

56

-42.0

50

-42.1

46

-42.8

Report # R0403232(Base)Rpt

Page 9 of 24

FCC Part 15.249 Test Report

Continental Conair Limited

Conducted Emissions Test Data (Model: GH3110 & GH3100)

Frequency MHz
4.10 1.35 8.10 8.13 1.35 8.10 4.10 0.17 0.17 0.17 8.13 0.17

LINE CONDUCTED EMISSIONS

Amplitude

Detector

dBµV

Qp/Ave/Peak

11.8

AVG

11.6

AVG

18.9

QP

8.3

AVG

14.2

QP

6.8

AVG

11.2

QP

7.3

AVG

6.2

AVG

15.6

QP

8.5

QP

9.9

QP

Phase Line/Neutral
Line Neutral Neutral
Line Neutral Neutral
Line Line Neutral Line Line Neutral

FCC ID: LBBGH3100

FCC CLASS B

Limit

Margin

dBµV

dB

46

-34.2

46

-34.4

60

-41.1

50

-41.7

56

-41.8

50

-43.2

56

-44.8

55

-47.7

55

-48.8

65

-49.4

60

-51.5

65

-55.1

Plot of Conducted Emissions Test Data
Plot of Conducted Emissions test data was presented hereinafter as reference.

Report # R0403232(Base)Rpt

Page 10 of 24

FCC Part 15.249 Test Report

Continental Conair Limited

FCC ID: LBBGH3100

Report # R0403232(Base)Rpt

Page 11 of 24

FCC Part 15.249 Test Report

Continental Conair Limited

FCC ID: LBBGH3100

Report # R0403232(Base)Rpt

Page 12 of 24

FCC Part 15.249 Test Report

Continental Conair Limited

FCC ID: LBBGH3100

Report # R0403232(Base)Rpt

Page 13 of 24

FCC Part 15.249 Test Report

Continental Conair Limited

FCC ID: LBBGH3100

Report # R0403232(Base)Rpt

Page 14 of 24

FCC Part 15.249 Test Report

Continental Conair Limited

FCC ID: LBBGH3100

Report # R0403232(Base)Rpt

Page 15 of 24

FCC Part 15.249 Test Report

Continental Conair Limited

FCC ID: LBBGH3100

Report # R0403232(Base)Rpt

Page 16 of 24

FCC Part 15.249 Test Report

Continental Conair Limited

FCC ID: LBBGH3100

§15.209(a), §15.205 & §15.249 - RADIATED EMISSION DATA
Measurement Uncertainty
All measurements involve certain levels of uncertainties, especially in field of EMC. The factors contributing to uncertainties are spectrum analyzer, cable loss, antenna factor calibration, antenna directivity, antenna factor variation with height, antenna phase center variation, antenna factor frequency interpolation, measurement distance variation, site imperfections, mismatch (average), and system repeatability.
Based on NIS 81, The Treatment of Uncertainty in EMC Measurements, the best estimate of the uncertainty of a radiation emissions measurement at BACL is +4.0 dB.

EUT Setup
The radiated emission tests were performed in the open area 3-meter test site, using the setup in accordance with ANSI C63.4-2001. The specification used was the FCC 15 Subpart C limits. The spacing between the peripherals was 10 centimeters. External I/O cables were draped along the edge of the test table and bundle as required. The host PC system was connected with 120Vac/60Hz power source.

Spectrum Analyzer Setup
According to FCC Rules, 47 CFR 15.33 (a) (1), the system was tested to 10GHz. During the radiated emission test, the spectrum analyzer was set with the following configurations:

Frequency Range Below 30MHz 30 ­ 1000MHz Above 1000MHz

RBW 10kHz 100kHz 1MHz

Test Equipment List and Details

Video B/W 10kHz 100kHz 1MHz

Manufacturer Description

HP

Spectrum Analyzer

Spectrum Analyzer HP
Display

HP

Quasi-Peak Adapter

Agilent

Amplifier

Electro-Metrics Biconical Antenna

Electro-Metrics Logperiodic Antenna

HP

Spectrum Analyzer

Model 8568B
85662A
85650A 8447D EM-6912 EM-6950 8565EC

Serial Number 2601A02165
3026A20081
3019A05393 2944A10187
585 788 3946A00131

Cal. Date 2003-07-07
2003-06-13
2003-06-13 2003-09-23 2004-04-17 2004-04-15 2003-06-30

* Statement of Traceability: BACL Corp. certifies that all calibrations have been performed in accordance to NVLAP requirements, traceable to the NIST.

Report # R0403232(Base)Rpt

Page 17 of 24

FCC Part 15.249 Test Report

Continental Conair Limited

Environmental Conditions

Temperature: Relative Humidity: ATM Pressure:

15 ° C 78% 1016 mbar

FCC ID: LBBGH3100

Test Procedure
For the radiated emissions test, the power cord of the host system and all support equipment were connected to the AC floor outlet. Maximizing procedure was performed on the six (6) highest emissions to ensure EUT is compliant with all installation combinations. All data was recorded in the peak detection mode. Quasi-peak readings was performed only when an emission was found to be marginal (within -4 dB of specification limits), and are distinguished with a "Qp" in the data table.
Corrected Amplitude & Margin Calculation
The Corrected Amplitude is calculated by adding the Antenna Factor and Cable Factor, and subtracting the Amplifier Gain from the Amplitude reading. The basic equation is as follows:
Corr. Ampl. = Indicated Reading + Antenna Factor + Cable Factor - Amplifier Gain
The "Margin" column of the following data tables indicates the degree of compliance with the applicable limit. For example, a margin of -7dB means the emission is 7dB below the maximum limit for applicable limits. The equation for margin calculation is as follows:
Margin = Corr. Ampl. - Applicable Limit

Summary of Test Results
According to the recorded data in following table, the EUT complied with the FCC Title 47, Part 15, Subpart C, section 15.205, 15.209, and 15.249 after tested to 10th harmonics as required by FCC and had the worst margin of:
Model: GH3150
Base, 1GHz - 10GHz, 3 Meters
-3.22 dB at 924.045 MHz in the Vertical polarization at Low Frequency -4.39 dB at 926.219 MHz in the Vertical polarization at High Frequency -5.69 dB at 266.680 MHz in the Horizontal polarization at Unintentional Emission
Model: GH3110 & GH3100
Base, 1GHz - 10GHz, 3 Meters
-1.7 dB at 924.045 MHz in the Vertical polarization at Low Frequency -1.8 dB at 926.219 MHz in the Vertical polarization at High Frequency -8.2 dB at 261.990 MHz in the Horizontal polarization at Unintentional Emission

Report # R0403232(Base)Rpt

Page 18 of 24

FCC Part 15.249 Test Report

Continental Conair Limited
Radiated Emissions Test Result Data

FCC ID: LBBGH3100

Base Unit, 1GHz to 10GHz, 3 meters (For Model: GH3150)

INDICATED

TABLE ANTENNA

Frequency Ampl.

Angle Height Polar

Comments

MHz

dBµV/m

Degree Meter H/ V

CORRECTION FACTOR

Antenna Cable Amp.

dBµV/m

DB

dB

CORRECTED AMPLITUDE
Corr. Ampl.
dBµV/m

Low Channel

924.045 91.67 Fund/Peak 270 1.8 V 23.4 4.03 28.32

924.045 88.67 Fund/Peak 0

1 H 23.4 4.03 28.32

1848.090 44.67 Ave

45 1.5 V 25.3 2.60 37

2772.135 36.83 Ave

60

1 V

29 3.68 35.64

2772.135 34.50 Ave

100 1.4 H

29 3.68 35.64

1848.090 39.17 Ave

100 1 H 25.3 2.60 37

2772.135 47.50 Peak

60

1 V

29 3.68 35.64

2772.135 46.17 Peak

100 1.4 H

29 3.68 35.64

1848.090 50.67 Peak

45 1.5 V 25.3 2.60 37

1848.090 48.33 Peak 100 1 H 25.3 2.60 37

High Channel

90.78 87.78 35.57 33.87 31.54 30.07 44.54 43.21 41.57 39.23

926.219 926.219 926.219 926.219 1852.437 2778.656 2778.656 1852.437 2778.656 2778.656 1852.437 1852.437
266.680 262.142 262.112 266.657 460.680 460.313

90.5 90.5 87.83 87.83 43.83 37.33 37 38.2 47.5 47.5 50.17 46.5

Fund/Peak Fund/Peak Fund/Peak Fund/Peak
Ave Ave Ave Ave Peak Peak Peak Peak

52.67

/

51.17

/

50.50

/

49.50

/

38.33

/

35.50

/

270 2 V 23.4 4.03 28.32

270 2 V 23.4 4.03 28.32

0 1.1 H 23.4 4.03 28.32

0 1.1 H 23.4 4.03 28.32

30 1.4 V 25.3 2.60 37

60

1 V

29 3.68 35.64

90 1.8 H

29 3.68 35.64

100 1 H 25.3 2.60 37

60

1 V

29 3.68 35.64

90 1.8 H

29 3.68 35.64

30 1.4 V 25.3 2.60 37

100 1 H 25.3 2.60 37

Unintentional Emission, 30MHz to 1000MHz

80 1.4 H 13.4 2.2 27.96

330 1.5 H 13.4 2.2 27.96

100 2 V 13.4 2.2 27.96

200 2.2 V 13.4 2.2 27.96

30

1 V 17.5

3 28.66

0

1.6 H 17.5

3 28.66

89.61 89.61 86.94 86.94 34.73 34.37 34.04 29.10 44.54 44.54 41.07 37.40
40.31 38.81 38.14 37.14 30.17 27.34

FCC 15 Subpart C

Limit

Margin

dBµV/m

dB

94

-3.22

94

-6.22

54

-18.43

54

-20.13

54

-22.46

54

-23.93

74

-29.46

74

-30.79

74

-32.43

74

-34.77

94

-4.39

94

-4.39

94

-7.06

94

-7.06

54

-19.27

54

-19.63

54

-19.96

54

-24.90

74

-29.46

74

-29.46

74

-32.93

74

-36.60

46

-5.69

46

-7.19

46

-7.86

46

-8.86

46

-15.83

46

-18.66

Ave.: Average Fund: Fundamental
Note: This test was performed by placing the handset on 3 orthogonal axis.

Report # R0403232(Base)Rpt

Page 19 of 24

FCC Part 15.249 Test Report

Continental Conair Limited Base Unit, 1GHz to 10GHz, 3 meters (For Model: GH3110 & GH3100)

FCC ID: LBBGH3100

INDICATED

TABLE ANTENNA

Frequency Ampl.

Angle Height Polar

Comments

MHz

dBµV/m

Degree Meter H/ V

CORRECTION FACTOR

Antenna Cable Amp.

dBµV/m

DB

dB

CORRECTED AMPLITUDE
Corr. Ampl.
dBµV/m

Low Channel

924.045 93.2 Fund/QP 30 1.5 V 23.4 4.0 28.3

92.3

924.045 89.9 Fund/QP 0 1.2 H 23.4 4.0 28.3

89.0

1848.090 50.3 Peak

45 1.5 V 25.3 2.6 37.1

41.1

1848.090 48.3 Peak 100 1.6 H 25.3 2.6 37.1

39.1

1848.090 44.5 Ave

45 1.5 V 25.3 2.6 37.1

35.3

1848.090 39.1 Ave

100 1.6 H 25.3 2.6 37.1

29.9

2772.135 47.3 Peak

30 1.5 V 29.0 3.7 35.6

44.4

2772.135 44.7 Peak

90 1.4 H 29.0 3.7 35.6

41.8

2772.135 37.4 Ave

30 1.5 V 29.0 3.7 35.6

34.5

2772.135 35.5 Ave

90 1.4 H 29.0 3.7 35.6

32.6

High Channel

926.219 93.1 Fund/QP 270 1.2 V 23.4 4.0 28.3

92.2

926.219 89.7 Fund/QP 0 1.1 H 23.4 4.0 28.3

88.8

1852.437 50.4 Peak 310 1.5 V 25.3 2.6 37.1

41.2

1852.437 48.1 Peak 120 1.0 H 25.3 2.6 37.1

38.9

1852.437 43.2 Ave

310 1.5 V 25.3 2.6 37.1

34.0

1852.437 39.3 Ave

120 1.0 H 25.3 2.6 37.1

30.1

2778.656 47.4 Peak

0 1.2 V 29.0 3.7 35.6

44.5

2778.656 44.9 Peak

60 1.5 H 29.0 3.7 35.6

42.0

2778.656 37.3 Ave

0 1.2 V 29.0 3.7 35.6

34.4

2778.656 35.2 Ave

60 1.5 H 29.0 3.7 35.6

32.3

Unintentional Emission, 30MHz to 1000MHz

261.990 50.2

/

60 1.8 V 13.4 2.2 28.0

37.8

266.730 49.1

/

270 2.0 V 13.4 2.2 28.0

36.7

460.520 38.7

/

120 1.5 V 17.5 3.0 28.7

30.5

261.840 50.9

/

310 1.6 H 13.4 2.2 28.0

38.5

266.730 52.7

/

90 1.5 H 13.4 2.2 28.0

40.3

459.920 35.5

/

45 1.2 H 17.1 3.0 28.6

27.0

FCC 15 Subpart C

Limit

Margin

dBµV/m

dB

94

-1.7

94

-5.0

74

-32.9

74

-34.9

54

-18.7

54

-24.1

74

-29.6

74

-32.2

54

-19.5

54

-21.4

94

-1.8

94

-5.2

74

-32.8

74

-35.1

54

-20.0

54

-23.9

74

-29.5

74

-32.0

54

-19.6

54

-21.7

46

-8.2

46

-9.3

46

-15.5

46

-7.5

46

-5.7

46

-19.0

Ave.: Average Fund: Fundamental QP: Qusi-Peak
Note: This test was performed by placing the handset on 3 orthogonal axis.

Report # R0403232(Base)Rpt

Page 20 of 24

FCC Part 15.249 Test Report

Continental Conair Limited

FCC ID: LBBGH3100

§15.249(c) ­ BAND-EDGE TESTING
Standard Applicable
Requirements: FCC 15.249 (c), the emission power at the START and STOP frequencies shall be at least 50 dB below the level of the fundamental or to the general radiated emission limits in FCC 15.209, whichever is the lesser attenuation.
Test Procedure
With the EUT's antenna attached, the EUT's radiated emission power was received by the test antenna which was connected to the spectrum analyzer with the START and STOP frequencies set to the EUT's operation band.

Test Equipment List and Details

Manufacturer Description

HP

Spectrum Analyzer

Model 8565EC

Serial Number 3946A00131

Cal. Date 2003-06-30

* Statement of Traceability: BACL Corp. certifies that all calibrations have been performed in accordance to NVLAP requirements, traceable to the NIST.

Environmental Conditions

Temperature: Relative Humidity: ATM Pressure:

15 ° C 78% 1016 mbar

Test Results
Refer to the attached plots.

Report # R0403232(Base)Rpt

Page 21 of 24

FCC Part 15.249 Test Report

Continental Conair Limited Model: GH3150

FCC ID: LBBGH3100

Report # R0403232(Base)Rpt

Page 22 of 24

FCC Part 15.249 Test Report

Continental Conair Limited Model: GH3110 & GH3100

FCC ID: LBBGH3100

Report # R0403232(Base)Rpt

Page 23 of 24

FCC Part 15.249 Test Report

Continental Conair Limited

FCC ID: LBBGH3100

Report # R0403232(Base)Rpt

Page 24 of 24

FCC Part 15.249 Test Report



Related FCC IDs:

Search Any Device: