SZ22100161W17 Tengfei NX729J NFC DXX
Morlab
Test Report
Shenzhen Tengfei Technology Management Ltd. NX729J 5G Mobile Phone 2A9QD-NX729J 2A9QDNX729J nx729j
download (pdf)
NX729J 5 G Mobile Phone by Shenzhen Tengfei Management
Not Your Device? Search For Manuals or Datasheets below:
File Info : application/pdf, 24 Pages, 829.37KB
Document DEVICE REPORTNX729J-Test-Report-Shenzhen-Tengfei-Management-2a9qd-nx729j-ex-1-4REPORT No.SZ22100161W17 TEST REPORT APPLICANT PRODUCT NAME : Shenzhen Tengfei Technology Management Ltd. : 5G Mobile Phone MODEL NAME : NX729J BRAND NAME : REDMAGIC FCC ID : 2A9QD-NX729J STANDARD(S) : 47 CFR Part 15 Subpart C RECEIPT DATE : 2022-11-01 TEST DATE : 2022-11-30 to 2022-12-01 ISSUE DATE : 2022-12-16 Edited by: Zeng Xiaoying (Rapporteur) Approved by: Shen Junsheng (Supervisor) NOTE: This document is issued by Shenzhen Morlab Communications Technology Co., Ltd., the test report shall not be reproduced except in full without prior written permission of the company. The test results apply only to the particular sample(s) tested and to the specific tests carried out which is available on request for validation and information confirmed at our website. MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: [email protected] Page 1 of 24 REPORT No.SZ22100161W17 DIRECTORY 1. Technical Information 3 1.1. Applicant and Manufacturer Information 3 1.2. Equipment Under Test (EUT) Description 3 1.3. Test Standards and Results 5 1.4. Environmental Conditions 5 2. 47 CFR Part 15C Requirements 6 2.1. Antenna Requirement 6 2.2. Conducted Emission 7 2.3. Radiated Emission 11 2.4. Frequency Tolerance 18 2.5. 20 dB Bandwidth20 Annex A Test Uncertainty 22 Annex B Testing Laboratory Information 23 Version 1.0 Change History Date 2022-12-16 Reason for change First edition MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: [email protected] Page 2 of 24 1. Technical Information REPORT No.SZ22100161W17 Note: Provide by applicant. 1.1. Applicant and Manufacturer Information Applicant: Applicant Address: Manufacturer: Manufacturer Address: Shenzhen Tengfei Technology Management Ltd. Room 3101, Building D1, Chuangzhi Yuncheng, Liuxian Avenue, Xili Street, Nanshan, Shenzhen, China Shenzhen Tengfei Technology Management Ltd. Room 3101, Building D1, Chuangzhi Yuncheng, Liuxian Avenue, Xili Street, Nanshan, Shenzhen, China 1.2. Equipment Under Test (EUT) Description Product Name: Sample No.: Hardware Version: Software Version: Operating Frequency: Modulation Type: Antenna Type: Accessory Information: 5G Mobile Phone 1# NX729J_V1AMB NX729J_UNCommon_V3.03 13.56MHz ASK Loop Antenna Battery Brand Name: ATL Model No.: Li3928T89P8h603285 Serial No.: N/A Capacity: 2860mAh Rated Voltage: 7.78V Charge Limit: 8.9V Manufacturer: Dongguan Amperex Technology Limited MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: [email protected] Page 3 of 24 REPORT No.SZ22100161W17 AC Adapter Brand Name: N/A Model No.: STC-A59152050AC-Z Serial No.: N/A Accessory Information: Rated Output: 5V 3A, 9V 3A, 15V 3A, 20V 3.25A, PPS: 5.0V-11.0V 5.0A, 5.0V-20.0V 3.25A Rated Input: 100-240V 50/60Hz, 1.5A Manufacturer: ShenZhen KunXing Technology Co.,Ltd. USB Cable Model No.: N52111200016D Note 1: For a more detailed description, please refer to Specification or User's Manual supplied by the applicant and/or manufacturer. MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: [email protected] Page 4 of 24 1.3. Test Standards and Results REPORT No.SZ22100161W17 The objective of the report is to perform testing according to 47 CFR Part 15 Subpart C for the EUT FCC ID Certification: No. Identity Document Title 1 47 CFR Part 15 (10-1-15 Edition) Radio Frequency Devices Test detailed items/section required by FCC rules and results are as below: No. Section Description Test Date Test Engineer Result Method Determination /Remark 1 15.203 Antenna Requirement N/A N/A PASS No deviation 2 15.207 Conducted Emission Nov. 30, 2022 Fan Zehang PASS No deviation 3 15.209 15.225(a) (b) (c)(d) Radiated Emission Dec. 01, 2022 Su Zhan PASS No deviation 4 15.225(e) Frequency Tolerance Nov. 30, 2022 Zhong Yanshan PASS No deviation 5 15.215(c) 20dB Bandwidth Dec. 01, 2022 Su Zhan PASS No deviation Note 1: The tests were performed according to the method of measurements prescribed in ANSI C63.10-2013. The EUT has been tested under continuous operating condition. Note 2: Additions to, deviation, or exclusions from the method shall be judged in the "method determination" column of add, deviate or exclude from the specific method shall be explained in the "Remark" of the above table. Note 3: When the test result is a critical value, we will use the measurement uncertainty give the judgment result based on the 95% confidence intervals. 1.4. Environmental Conditions During the measurement, the environmental conditions were within the listed ranges: Temperature (°C): Relative Humidity (%): Atmospheric Pressure (kPa): 15-35 30-60 86-106 MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: [email protected] Page 5 of 24 REPORT No.SZ22100161W17 2. 47 CFR Part 15C Requirements 2.1. Antenna Requirement 2.1.1. Applicable Standard According to FCC 15.203, an intentional radiator shall be designed to ensure that no antenna other than that furnished by the responsible party shall be used with the device. The use of a permanently attached antenna or of an antenna that uses a unique coupling to the intentional radiator shall be considered sufficient to comply with the provisions of this section. 2.1.2. Test Result: Compliant The EUT has a permanently and irreplaceable attached antenna. Please refer to the EUT internal photos. MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: [email protected] Page 6 of 24 2.2. Conducted Emission REPORT No.SZ22100161W17 2.2.1. Test Requirement According to FCC section 15.207, the radio frequency voltage that is conducted back onto the AC power line on any frequency within the band 150kHz to 30MHz shall not exceed the limits in the following table, as measured using a 50µH/50 line impedance stabilization network (LISN). Frequency Range (MHz) Conducted Limit (dBµV) Quai-peak Average 0.15 - 0.50 66 to 56 56 to 46 0.50 - 5 56 46 5 - 30 60 50 NOTE: (a) The lower limit shall apply at the band edges. (b) The limit decreases linearly with the logarithm of the frequency in the range 0.15 - 0.50MHz. 2.2.2. Test Setup The EUT is placed on a 0.8m high insulating table, which stands on the grounded conducting floor, and keeps 0.4m away from the grounded conducting wall. The EUT is connected to the power mains through a LISN which provides 50/50µH of coupling impedance for the measuring instrument. A Pulse Limiter is used to protect the measuring instrument. The factors of the whole test system are calibrated to correct the reading. MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: [email protected] Page 7 of 24 REPORT No.SZ22100161W17 2.2.3. Test Result The maximum conducted interference is searched using Peak (PK), if the emission levels more than the AV and QP limits, and that have narrow margins from the AV and QP limits will be re-measured with AV and QP detectors. Tests for both L phase and N phase lines of the power mains connected to the EUT are performed. Set RBW=9kHz, VBW=30kHz. Refer to recorded points and plots below. Note: Both of the test voltage AC 120V/60Hz and AC 230V/50Hz were considered and tested respectively, only the results of the worst case AC 120V/60Hz were recorded in this report. A.Test Setup: Test Mode: EUT+Adapter+Earphone+13.56MHz TX Test voltage: AC 120V/60Hz The measurement results are obtained as below: E [dBV] =UR + LCable loss [dB] + AFactor UR: Receiver Reading AFactor: Voltage division factor of LISN MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: [email protected] Page 8 of 24 B.Test Plot: REPORT No.SZ22100161W17 (L Phase) No. Fre. (MHz) Emission Level (dBµV) Quai-peak Average 1 0.1723 54.73 45.25 2 0.2588 46.64 35.30 3 0.3118 30.67 23.50 4 0.3379 36.43 26.23 5 0.4308 35.17 26.91 6 0.7779 34.84 26.65 Limit (dBµV) Quai-peak 64.85 61.47 59.92 59.25 57.24 56.00 Average 54.85 51.47 49.92 49.25 47.24 46.00 Power-line Verdict PASS PASS Line PASS PASS PASS PASS MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: [email protected] Page 9 of 24 REPORT No.SZ22100161W17 (N Phase) No. Fre. (MHz) Emission Level (dBµV) Quai-peak Average 1 0.1945 49.82 37.30 2 0.2081 53.74 43.43 3 0.2925 32.52 24.96 4 0.5524 26.55 21.32 5 0.7644 34.67 25.00 6 8.2630 30.95 22.67 Limit (dBµV) Quai-peak 63.84 63.28 60.45 56.00 56.00 60.00 Average 53.84 53.28 50.45 46.00 46.00 50.00 Power-line Verdict Neutral PASS PASS PASS PASS PASS PASS MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: [email protected] Page 10 of 24 2.3. Radiated Emission REPORT No.SZ22100161W17 2.3.1. Test Requirement Radiated Emission <30MHz (9 kHz-30MHz, E-field) According to FCC section 15.225, for <30MHz, Radiated emissions were measured according to ANSIC63.4. The EUT was set to transmit at the highest output power. The EUT was set 30 meter away from the measuring antenna. The loop antenna was positioned 1 meter above the ground from the center of the loop. The measuring bandwidth was set to 10KHz. (Note: During testing the receive antenna was rotated about its axis to maximize the emission from the EUT) There was no detected Restricted bands and Radiated Spurious emission below 30MHz. The 30m limit was converted to 3m Limit using square factor(x) as it was found by measurements as follows; 3 m Limit(dBuV/m) = 20log(X)+40log(30/3)= 20log(15848)+40log(30/3) = 124dBuV Except as provided elsewhere in this Subpart, the emissions from an intentional radiator shall not exceed the field strength levels specified in the following table: Frequency Range (MHz) Field Strength@30m µV/m dBµV/m Field Strength@3m dBµV/m Below 13.110 30 29.5 69.5 13.110 ~ 13.410 106 40.5 80.5 13.410 ~ 13.553 334 50.5 90.5 13.553 ~13.567 15.848 84 124 13.567 ~ 13.710 334 50.5 90.5 13.710 ~14.010 106 40.5 80.5 Above 14.010 30 29.5 69.5 NOTE: a) Field Strength (dBµV/m) = 20*log[Field Strength (µV/m)]. b) In the emission tables above, the tighter limit applies at the band edges. Radiated Emission >30MHz (30MHz-1GHz, E-field) According to FCC section 15.205, the field strength of radiated emissions from intentional radiators at a distance of 3 meters shall not exceed the following values: Frequency Range (MHz) µV/m Field Strength dBµV/m 30 - 88 100 40 88 - 216 150 43.5 216 - 960 200 46 Above 960 500 54 NOTE: a) Field Strength (dBµV/m) = 20*log[Field Strength (µV/m)]. b) In the emission tables above, the tighter limit applies at the band edges. MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: [email protected] Page 11 of 24 2.3.2. Test Setup 1) For radiated emissions below 30MHz REPORT No.SZ22100161W17 2) For radiated emissions from 30MHz to1GHz The test is performed in a 3m Semi-Anechoic Chamber; the antenna factor, cable loss and so on of the site (factors) is calculated to correct the reading. The EUT is placed on a 0.8m high insulating MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: [email protected] Page 12 of 24 REPORT No.SZ22100161W17 Turn Table, and keeps 3m away from the Test Antenna, which is mounted on a variable-height antenna master tower. For the test Antenna: In the frequency range of 9 kHz to 30MHz, magnetic field is measured with Loop Test Antenna. The Test Antenna is positioned with its plane vertical at 1m distance from the EUT. The center of the Loop Test Antenna is 1m above the ground. During the measurement the Loop Test Antenna rotates about its vertical axis for maximum response at each azimuth about the EUT. In the frequency range above 30MHz, Bi-Log Test Antenna (30MHz to 1GHz) was used. Test Antenna is 3m away from the EUT. Test Antenna height is varied from 1m to 4m above the ground to determine the maximum value of the field strength. The emission levels at both horizontal and vertical polarizations should be tested. For measurements below 30MHz, the emission limits shown in the above table are based on measurements employing a CISPR quasi-peak detector except for the frequency bands 9kHz-90 kHz, 110kHz-490 kHz. Radiated emission limits in these two bands are based on measurements employing an average detector. For measurements frequency range from 0.009MHz to 0.15MHz, the resolution bandwidth is set to 200Hz. For measurements frequency range from 0.15MHz to 30MHz the resolution bandwidth is set to 9kHz. For measurements below 1GHz the resolution bandwidth is set to 100kHz for peak detection measurements or 120kHz for quasi-peak detection measurements. Peak detection is used unless otherwise noted as quasi-peak. For measurements above 1GHz the resolution bandwidth is set to 1MHz, the video bandwidth is set to 3MHz for peak measurements and as applicable for average measurements. MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: [email protected] Page 13 of 24 REPORT No.SZ22100161W17 2.3.3. Test Result A.Radiated Emission <30MHz (9kHz-30MHz, opened) No. Frequency (MHz) Detector Type 1 0.009 Quasi Peak 2 0.012 Quasi Peak 3 0.014 Quasi Peak 4 0.020 Quasi Peak 5 0.180 Quasi Peak 6 13.56 Quasi Peak Level at 3m (dBV/m) 54.67 54.57 54.14 50.95 52.28 62.38 Limit at 3m (dBV/m) 128.52 126.02 124.68 121.58 102.50 124.0 MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: [email protected] Page 14 of 24 B.Radiated Emission <30MHz (9kHz-30MHz, closed) REPORT No.SZ22100161W17 No. Frequency (MHz) Detector Type 1 0.009 Quasi Peak 2 0.012 Quasi Peak 3 0.066 Quasi Peak 4 0.185 Quasi Peak 5 0.265 Quasi Peak 6 13.56 Quasi Peak Level at 3m (dBV/m) 54.31 54.73 49.93 51.76 50.07 55.17 Limit at 3m (dBV/m) 128.52 126.02 111.21 102.26 99.14 124.0 MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: [email protected] Page 15 of 24 C.Radiated Emission >30MHz (30MHz-1GHz) REPORT No.SZ22100161W17 (30MHz 1GHz, Test Antenna Horizontal) Fre. Pk QP AV Limit-PK Limit-QP Limit-AV No. ANT Verdict MHz dBµV/m dBµV/m dBµV/m dBµV/m dBµV/m dBµV/m 1 49.400 27.46 N/A N/A N/A 40.00 N/A H PASS 2 101.780 31.39 N/A N/A N/A 43.50 N/A H PASS 3 343.310 30.27 N/A N/A N/A 46.00 N/A H PASS 4 569.320 33.16 N/A N/A N/A 46.00 N/A H PASS 5 778.840 35.10 N/A N/A N/A 46.00 N/A H PASS 6 904.940 37.86 N/A N/A N/A 46.00 N/A H PASS MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: [email protected] Page 16 of 24 REPORT No.SZ22100161W17 (30MHz 1GHz, Test Antenna Vertical) No. Fre. Pk QP AV Limit-PK Limit-QP Limit-AV ANT Verdict MHz dBµV/m dBµV/m dBµV/m dBµV/m dBµV/m dBµV/m 1 46.490 28.89 N/A N/A N/A 40.00 N/A V PASS 2 116.330 30.66 N/A N/A N/A 43.50 N/A V PASS 3 337.490 30.50 N/A N/A N/A 46.00 N/A V PASS 4 579.990 34.10 N/A N/A N/A 46.00 N/A V PASS 5 776.900 34.41 N/A N/A N/A 46.00 N/A V PASS 6 913.670 39.28 N/A N/A N/A 46.00 N/A V PASS MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: [email protected] Page 17 of 24 2.4. Frequency Tolerance REPORT No.SZ22100161W17 2.4.1. Test Requirement According to FCC section 15.225, the devices operating in the 13.553~13.567 MHz shall maintain the carrier frequency within 0.01% of the operating frequency over the temperature variation of -20°C to +50°C using an environmental chamber. The primary supply voltage is varied from 85% to 115% of the voltage normally at the input to the device or at the power supply terminals if cables are not normally supplied. 2.4.2. Test Setup Temperature Chamber EUT DC Power Supply The EUT, which is powered by the DC Power Supply directly, is located in the Temperature Chamber. The EUT was measured by transmitter mode continuously. MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: [email protected] Page 18 of 24 2.4.3. Test Result Operating Frequency: 13,560,000 Hz Deference Voltage: 7.78V Deviant Limit: ±0.01% Test Conditions VOLTAGE (%) Power Temperature (VDC) (°C) 100 -20 100 -10 100 0 100 +10 100 7.78 +20 100 +25 100 +30 100 +40 100 +50 85 7.00 +20 115 8.90 +20 REPORT No.SZ22100161W17 Fre. Dev. (Hz) 226 203 188 156 153 140 147 152 167 175 166 Deviation (%) 0.00167 0.00150 0.00139 0.00115 0.00113 0.00103 0.00108 0.00112 0.00123 0.00129 0.00122 Verdict PASS MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: [email protected] Page 19 of 24 2.5. 20 dB Bandwidth REPORT No.SZ22100161W17 2.5.1. Standard Applicable According to FCC section 15.215(c), the 20dB bandwidth should be contained within the frequency band designated in the rule section under which the EUT is operated, it was measured with a spectrum analyzer connected the EUT while the EUT is operating in transmission mode. 2.5.2. Test Setup MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: [email protected] Page 20 of 24 REPORT No.SZ22100161W17 2.5.3. Test Result Centre Frequency 13.56MHz Measurement 20 dB Bandwidth (kHz) Frequency Range (MHz) 1.89 13. 55905 to 13.56094 20dB Bandwidth (kHz) Limit Frequency Range(MHz) 14 13.553 to 13.567 Verdict PASS 1 MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: [email protected] Page 21 of 24 Annex A Test Uncertainty REPORT No.SZ22100161W17 The uncertainty is calculated using the methods suggested in the "Guide to the Expression of Uncertainty in Measurement" (GUM) published by ISO. Radiated Emission: ±3.1dB Conducted Emission: ±1.8dB Bandwidth: ±5% Frequency Tolerance: ±5% MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: [email protected] Page 22 of 24 REPORT No.SZ22100161W17 Annex B Testing Laboratory Information 1. Identification of the Responsible Testing Laboratory Laboratory Name: Laboratory Address: Telephone: Facsimile: Shenzhen Morlab Communications Technology Co., Ltd. FL.3, Building A, FeiYang Science Park, No.8 LongChang Road, Block 67, BaoAn District, ShenZhen, GuangDong Province, P. R. China +86 755 36698555 +86 755 36698525 2. Identification of the Responsible Testing Location Name: Address: Shenzhen Morlab Communications Technology Co., Ltd. FL.3, Building A, FeiYang Science Park, No.8 LongChang Road, Block 67, BaoAn District, ShenZhen, GuangDong Province, P. R. China 3. Facilities and Accreditations All measurement facilities used to collect the measurement data are located at FL.3, Building A, FeiYang Science Park, Block 67, BaoAn District, Shenzhen, 518101 P. R. China. The test site is constructed in conformance with the requirements of ANSI C63.10-2013 and CISPR Publication 22; the FCC designation number is CN1192, the test firm registration number is 226174. MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: [email protected] Page 23 of 24 REPORT No.SZ22100161W17 4. Test Equipments Utilized 4.1 Test Equipments Equipment Name Serial No. Receiver MY54130016 Test Antenna Bi-Log 9163-519 Test Antenna Loop 1520-022 Anechoic Chamber N/A Temperature Chamber 12108015 Type N9038A VULB 9163 FMZB1519 9m*6m*6m DTL-003S101 Manufacturer Cal. Date Due Date Agilent 2022.07.06 2023.07.05 Schwarzbeck 2022.05.25 2025.05.24 Schwarzbeck 2022.02.11 2025.02.10 CRT 2020.01.06 2023.01.05 YOMA 2022.10.10 2023.10.09 4.2 Conducted Emission Test Equipments Equipment Name Serial No. Type Receiver MY56400093 N9038A LISN 812744 NSLK 8127 Pulse Limiter VTSD 9561 VTSD (10dB) F-B #206 9561-F Coaxial Cable(BNC) CB01 EMC01 (30MHz-26GHz) Notebook computer 20210357 P144G Manufacturer KEYSIGHT Schwarzbeck Schwarzbeck Cal. Date Due Date 2022.03.03 2023.03.02 2022.03.03 2023.03.02 2022.07.06 2023.07.05 Morlab N/A N/A DELL N/A N/A 4.3 Test Software Utilized Model MORLAB EMCR V1.2 TS+ -[JS32-CE] PMM Emission Suite Software Version Version 1.0 Version 2.5.0.0 Version 2.02 Manufacturer MORLAB Tonscend narda END OF REPORT MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: [email protected] Page 24 of 24
Related FCC IDs:
- 2A9QD-NX729J - Shenzhen Tengfei Technology Management Ltd. 5G Mobile Phone [-NX729J] Acrobat Distiller 9.3.2 (Windows)