REPORT No.SZ22100161W17
TEST REPORT

APPLICANT PRODUCT NAME

:

Shenzhen Tengfei Technology Management Ltd.

: 5G Mobile Phone

MODEL NAME

: NX729J

BRAND NAME

: REDMAGIC

FCC ID

: 2A9QD-NX729J

STANDARD(S)

: 47 CFR Part 15 Subpart C

RECEIPT DATE

: 2022-11-01

TEST DATE

: 2022-11-30 to 2022-12-01

ISSUE DATE

: 2022-12-16

Edited by:

Zeng Xiaoying (Rapporteur)

Approved by: Shen Junsheng (Supervisor)

NOTE: This document is issued by Shenzhen Morlab Communications Technology Co., Ltd., the test report shall not be reproduced except in full without prior written permission of the company. The test results apply only to the particular sample(s) tested and to the specific tests carried out which is available on request for validation and information confirmed at our website.

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: [email protected]

Page 1 of 24

REPORT No.SZ22100161W17
DIRECTORY
1. Technical Information 3 1.1. Applicant and Manufacturer Information  3 1.2. Equipment Under Test (EUT) Description  3 1.3. Test Standards and Results  5 1.4. Environmental Conditions 5 2. 47 CFR Part 15C Requirements  6 2.1. Antenna Requirement  6 2.2. Conducted Emission  7 2.3. Radiated Emission  11 2.4. Frequency Tolerance  18 2.5. 20 dB Bandwidth20 Annex A Test Uncertainty 22 Annex B Testing Laboratory Information  23

Version 1.0

Change History Date 2022-12-16

Reason for change First edition

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: [email protected]
Page 2 of 24

1. Technical Information

REPORT No.SZ22100161W17

Note: Provide by applicant.
1.1. Applicant and Manufacturer Information

Applicant: Applicant Address: Manufacturer: Manufacturer Address:

Shenzhen Tengfei Technology Management Ltd. Room 3101, Building D1, Chuangzhi Yuncheng, Liuxian Avenue, Xili Street, Nanshan, Shenzhen, China Shenzhen Tengfei Technology Management Ltd. Room 3101, Building D1, Chuangzhi Yuncheng, Liuxian Avenue, Xili Street, Nanshan, Shenzhen, China

1.2. Equipment Under Test (EUT) Description

Product Name: Sample No.: Hardware Version: Software Version: Operating Frequency: Modulation Type: Antenna Type:
Accessory Information:

5G Mobile Phone

1#

NX729J_V1AMB

NX729J_UNCommon_V3.03

13.56MHz

ASK

Loop Antenna

Battery

Brand Name:

ATL

Model No.:

Li3928T89P8h603285

Serial No.:

N/A

Capacity:

2860mAh

Rated Voltage:

7.78V

Charge Limit:

8.9V

Manufacturer:

Dongguan Amperex Technology Limited

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: [email protected]
Page 3 of 24

REPORT No.SZ22100161W17

AC Adapter

Brand Name:

N/A

Model No.:

STC-A59152050AC-Z

Serial No.:

N/A

Accessory Information: Rated Output:

5V 3A, 9V 3A, 15V 3A, 20V 3.25A, PPS: 5.0V-11.0V 5.0A, 5.0V-20.0V 3.25A

Rated Input:

100-240V 50/60Hz, 1.5A

Manufacturer:

ShenZhen KunXing Technology Co.,Ltd.

USB Cable

Model No.:

N52111200016D

Note 1: For a more detailed description, please refer to Specification or User's Manual supplied by

the applicant and/or manufacturer.

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: [email protected]
Page 4 of 24

1.3. Test Standards and Results

REPORT No.SZ22100161W17

The objective of the report is to perform testing according to 47 CFR Part 15 Subpart C for the EUT FCC ID Certification:

No. Identity

Document Title

1

47 CFR Part 15 (10-1-15 Edition)

Radio Frequency Devices

Test detailed items/section required by FCC rules and results are as below:

No. Section Description

Test Date

Test Engineer

Result

Method Determination
/Remark

1 15.203

Antenna Requirement

N/A

N/A

PASS No deviation

2 15.207

Conducted Emission

Nov. 30, 2022 Fan Zehang PASS No deviation

3

15.209 15.225(a) (b) (c)(d)

Radiated Emission

Dec. 01, 2022 Su Zhan PASS No deviation

4

15.225(e)

Frequency Tolerance

Nov. 30, 2022

Zhong Yanshan

PASS

No deviation

5 15.215(c) 20dB Bandwidth Dec. 01, 2022 Su Zhan PASS No deviation

Note 1: The tests were performed according to the method of measurements prescribed in ANSI

C63.10-2013. The EUT has been tested under continuous operating condition.

Note 2: Additions to, deviation, or exclusions from the method shall be judged in the "method

determination" column of add, deviate or exclude from the specific method shall be explained in

the "Remark" of the above table.

Note 3: When the test result is a critical value, we will use the measurement uncertainty give the

judgment result based on the 95% confidence intervals.

1.4. Environmental Conditions

During the measurement, the environmental conditions were within the listed ranges:

Temperature (°C): Relative Humidity (%): Atmospheric Pressure (kPa):

15-35 30-60 86-106

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: [email protected]
Page 5 of 24

REPORT No.SZ22100161W17
2. 47 CFR Part 15C Requirements
2.1. Antenna Requirement
2.1.1. Applicable Standard
According to FCC 15.203, an intentional radiator shall be designed to ensure that no antenna other than that furnished by the responsible party shall be used with the device. The use of a permanently attached antenna or of an antenna that uses a unique coupling to the intentional radiator shall be considered sufficient to comply with the provisions of this section.
2.1.2. Test Result: Compliant
The EUT has a permanently and irreplaceable attached antenna. Please refer to the EUT internal photos.

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: [email protected]
Page 6 of 24

2.2. Conducted Emission

REPORT No.SZ22100161W17

2.2.1. Test Requirement

According to FCC section 15.207, the radio frequency voltage that is conducted back onto the AC

power line on any frequency within the band 150kHz to 30MHz shall not exceed the limits in the

following table, as measured using a 50µH/50 line impedance stabilization network (LISN).

Frequency Range (MHz)

Conducted Limit (dBµV)

Quai-peak

Average

0.15 - 0.50

66 to 56

56 to 46

0.50 - 5

56

46

5 - 30

60

50

NOTE:

(a) The lower limit shall apply at the band edges.

(b) The limit decreases linearly with the logarithm of the frequency in the range 0.15 - 0.50MHz.

2.2.2. Test Setup

The EUT is placed on a 0.8m high insulating table, which stands on the grounded conducting floor, and keeps 0.4m away from the grounded conducting wall. The EUT is connected to the power mains through a LISN which provides 50/50µH of coupling impedance for the measuring instrument. A Pulse Limiter is used to protect the measuring instrument. The factors of the whole test system are calibrated to correct the reading.

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: [email protected]
Page 7 of 24

REPORT No.SZ22100161W17
2.2.3. Test Result
The maximum conducted interference is searched using Peak (PK), if the emission levels more than the AV and QP limits, and that have narrow margins from the AV and QP limits will be re-measured with AV and QP detectors. Tests for both L phase and N phase lines of the power mains connected to the EUT are performed. Set RBW=9kHz, VBW=30kHz. Refer to recorded points and plots below. Note: Both of the test voltage AC 120V/60Hz and AC 230V/50Hz were considered and tested respectively, only the results of the worst case AC 120V/60Hz were recorded in this report. A.Test Setup: Test Mode: EUT+Adapter+Earphone+13.56MHz TX Test voltage: AC 120V/60Hz The measurement results are obtained as below: E [dBV] =UR + LCable loss [dB] + AFactor UR: Receiver Reading AFactor: Voltage division factor of LISN

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: [email protected]
Page 8 of 24

B.Test Plot:

REPORT No.SZ22100161W17

(L Phase)

No.

Fre. (MHz)

Emission Level (dBµV) Quai-peak Average

1 0.1723

54.73

45.25

2 0.2588

46.64

35.30

3 0.3118

30.67

23.50

4 0.3379

36.43

26.23

5 0.4308

35.17

26.91

6 0.7779

34.84

26.65

Limit (dBµV)

Quai-peak 64.85 61.47 59.92 59.25 57.24 56.00

Average 54.85 51.47 49.92 49.25 47.24 46.00

Power-line Verdict

PASS

PASS

Line

PASS PASS

PASS

PASS

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: [email protected]
Page 9 of 24

REPORT No.SZ22100161W17

(N Phase)

No.

Fre. (MHz)

Emission Level (dBµV) Quai-peak Average

1 0.1945

49.82

37.30

2 0.2081

53.74

43.43

3 0.2925

32.52

24.96

4 0.5524

26.55

21.32

5 0.7644

34.67

25.00

6 8.2630

30.95

22.67

Limit (dBµV)

Quai-peak 63.84 63.28 60.45 56.00 56.00 60.00

Average 53.84 53.28 50.45 46.00 46.00 50.00

Power-line Verdict

Neutral

PASS PASS PASS PASS PASS PASS

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: [email protected]
Page 10 of 24

2.3. Radiated Emission

REPORT No.SZ22100161W17

2.3.1. Test Requirement

Radiated Emission <30MHz (9 kHz-30MHz, E-field)

According to FCC section 15.225, for <30MHz, Radiated emissions were measured according to

ANSIC63.4. The EUT was set to transmit at the highest output power. The EUT was set 30 meter

away from the measuring antenna. The loop antenna was positioned 1 meter above the ground

from the center of the loop. The measuring bandwidth was set to 10KHz. (Note: During testing the

receive antenna was rotated about its axis to maximize the emission from the EUT)

There was no detected Restricted bands and Radiated Spurious emission below 30MHz. The 30m

limit was converted to 3m Limit using square factor(x) as it was found by measurements as follows;

3 m Limit(dBuV/m) = 20log(X)+40log(30/3)= 20log(15848)+40log(30/3) = 124dBuV

Except as provided elsewhere in this Subpart, the emissions from an intentional radiator shall not

exceed the field strength levels specified in the following table:

Frequency Range (MHz)

Field Strength@30m

µV/m

dBµV/m

Field Strength@3m dBµV/m

Below 13.110

30

29.5

69.5

13.110 ~ 13.410

106

40.5

80.5

13.410 ~ 13.553

334

50.5

90.5

13.553 ~13.567

15.848

84

124

13.567 ~ 13.710

334

50.5

90.5

13.710 ~14.010

106

40.5

80.5

Above 14.010

30

29.5

69.5

NOTE: a) Field Strength (dBµV/m) = 20*log[Field Strength (µV/m)].

b) In the emission tables above, the tighter limit applies at the band edges.

Radiated Emission >30MHz (30MHz-1GHz, E-field)

According to FCC section 15.205, the field strength of radiated emissions from intentional radiators

at a distance of 3 meters shall not exceed the following values:

Frequency Range (MHz)

µV/m

Field Strength

dBµV/m

30 - 88

100

40

88 - 216

150

43.5

216 - 960

200

46

Above 960

500

54

NOTE: a) Field Strength (dBµV/m) = 20*log[Field Strength (µV/m)].

b) In the emission tables above, the tighter limit applies at the band edges.

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: [email protected]
Page 11 of 24

2.3.2. Test Setup 1) For radiated emissions below 30MHz

REPORT No.SZ22100161W17

2) For radiated emissions from 30MHz to1GHz

The test is performed in a 3m Semi-Anechoic Chamber; the antenna factor, cable loss and so on of the site (factors) is calculated to correct the reading. The EUT is placed on a 0.8m high insulating

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: [email protected]
Page 12 of 24

REPORT No.SZ22100161W17
Turn Table, and keeps 3m away from the Test Antenna, which is mounted on a variable-height antenna master tower.
For the test Antenna:
In the frequency range of 9 kHz to 30MHz, magnetic field is measured with Loop Test Antenna. The Test Antenna is positioned with its plane vertical at 1m distance from the EUT. The center of the Loop Test Antenna is 1m above the ground. During the measurement the Loop Test Antenna rotates about its vertical axis for maximum response at each azimuth about the EUT.
In the frequency range above 30MHz, Bi-Log Test Antenna (30MHz to 1GHz) was used. Test Antenna is 3m away from the EUT. Test Antenna height is varied from 1m to 4m above the ground to determine the maximum value of the field strength. The emission levels at both horizontal and vertical polarizations should be tested.
For measurements below 30MHz, the emission limits shown in the above table are based on measurements employing a CISPR quasi-peak detector except for the frequency bands 9kHz-90 kHz, 110kHz-490 kHz. Radiated emission limits in these two bands are based on measurements employing an average detector. For measurements frequency range from 0.009MHz to 0.15MHz, the resolution bandwidth is set to 200Hz. For measurements frequency range from 0.15MHz to 30MHz the resolution bandwidth is set to 9kHz.
For measurements below 1GHz the resolution bandwidth is set to 100kHz for peak detection measurements or 120kHz for quasi-peak detection measurements. Peak detection is used unless otherwise noted as quasi-peak.
For measurements above 1GHz the resolution bandwidth is set to 1MHz, the video bandwidth is set to 3MHz for peak measurements and as applicable for average measurements.

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: [email protected]
Page 13 of 24

REPORT No.SZ22100161W17
2.3.3. Test Result A.Radiated Emission <30MHz (9kHz-30MHz, opened)

No. Frequency (MHz) Detector Type

1

0.009

Quasi Peak

2

0.012

Quasi Peak

3

0.014

Quasi Peak

4

0.020

Quasi Peak

5

0.180

Quasi Peak

6

13.56

Quasi Peak

Level at 3m (dBV/m) 54.67 54.57 54.14 50.95 52.28 62.38

Limit at 3m (dBV/m) 128.52 126.02 124.68 121.58 102.50 124.0

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: [email protected]
Page 14 of 24

B.Radiated Emission <30MHz (9kHz-30MHz, closed)

REPORT No.SZ22100161W17

No. Frequency (MHz) Detector Type

1

0.009

Quasi Peak

2

0.012

Quasi Peak

3

0.066

Quasi Peak

4

0.185

Quasi Peak

5

0.265

Quasi Peak

6

13.56

Quasi Peak

Level at 3m (dBV/m) 54.31 54.73 49.93 51.76 50.07 55.17

Limit at 3m (dBV/m) 128.52 126.02 111.21 102.26 99.14 124.0

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: [email protected]
Page 15 of 24

C.Radiated Emission >30MHz (30MHz-1GHz)

REPORT No.SZ22100161W17

(30MHz ­ 1GHz, Test Antenna Horizontal)

Fre.

Pk

QP

AV Limit-PK Limit-QP Limit-AV

No.

ANT Verdict

MHz

dBµV/m dBµV/m dBµV/m dBµV/m dBµV/m dBµV/m

1

49.400

27.46

N/A

N/A

N/A

40.00

N/A

H

PASS

2 101.780 31.39

N/A

N/A

N/A

43.50

N/A

H

PASS

3 343.310 30.27

N/A

N/A

N/A

46.00

N/A

H

PASS

4 569.320 33.16

N/A

N/A

N/A

46.00

N/A

H

PASS

5 778.840 35.10

N/A

N/A

N/A

46.00

N/A

H

PASS

6 904.940 37.86

N/A

N/A

N/A

46.00

N/A

H

PASS

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: [email protected]
Page 16 of 24

REPORT No.SZ22100161W17

(30MHz ­ 1GHz, Test Antenna Vertical)

No.

Fre.

Pk

QP

AV

Limit-PK Limit-QP Limit-AV ANT Verdict

MHz

dBµV/m dBµV/m dBµV/m dBµV/m dBµV/m dBµV/m

1

46.490

28.89

N/A

N/A

N/A

40.00

N/A

V

PASS

2

116.330

30.66

N/A

N/A

N/A

43.50

N/A

V

PASS

3

337.490

30.50

N/A

N/A

N/A

46.00

N/A

V

PASS

4

579.990

34.10

N/A

N/A

N/A

46.00

N/A

V

PASS

5

776.900

34.41

N/A

N/A

N/A

46.00

N/A

V

PASS

6

913.670

39.28

N/A

N/A

N/A

46.00

N/A

V

PASS

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: [email protected]
Page 17 of 24

2.4. Frequency Tolerance

REPORT No.SZ22100161W17

2.4.1. Test Requirement
According to FCC section 15.225, the devices operating in the 13.553~13.567 MHz shall maintain the carrier frequency within 0.01% of the operating frequency over the temperature variation of -20°C to +50°C using an environmental chamber. The primary supply voltage is varied from 85% to 115% of the voltage normally at the input to the device or at the power supply terminals if cables
are not normally supplied.
2.4.2. Test Setup

Temperature Chamber

EUT

DC Power Supply

The EUT, which is powered by the DC Power Supply directly, is located in the Temperature Chamber. The EUT was measured by transmitter mode continuously.

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: [email protected]
Page 18 of 24

2.4.3. Test Result

Operating Frequency: 13,560,000 Hz

Deference Voltage: 7.78V

Deviant Limit: ±0.01%

Test Conditions

VOLTAGE (%) Power Temperature

(VDC)

(°C)

100

-20

100

-10

100

0

100

+10

100

7.78

+20

100

+25

100

+30

100

+40

100

+50

85

7.00

+20

115

8.90

+20

REPORT No.SZ22100161W17

Fre. Dev. (Hz)
226 203 188 156 153 140 147 152 167 175 166

Deviation (%)
0.00167 0.00150 0.00139 0.00115 0.00113 0.00103 0.00108 0.00112 0.00123 0.00129 0.00122

Verdict PASS

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: [email protected]
Page 19 of 24

2.5. 20 dB Bandwidth

REPORT No.SZ22100161W17

2.5.1. Standard Applicable
According to FCC section 15.215(c), the 20dB bandwidth should be contained within the frequency band designated in the rule section under which the EUT is operated, it was measured with a spectrum analyzer connected the EUT while the EUT is operating in transmission mode.

2.5.2. Test Setup

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: [email protected]
Page 20 of 24

REPORT No.SZ22100161W17

2.5.3. Test Result

Centre Frequency
13.56MHz

Measurement

20 dB Bandwidth
(kHz)

Frequency Range (MHz)

1.89

13. 55905 to 13.56094

20dB Bandwidth
(kHz)

Limit
Frequency Range(MHz)

14

13.553 to 13.567

Verdict PASS

1

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: [email protected]
Page 21 of 24

Annex A Test Uncertainty

REPORT No.SZ22100161W17

The uncertainty is calculated using the methods suggested in the "Guide to the Expression of

Uncertainty in Measurement" (GUM) published by ISO.

Radiated Emission:

±3.1dB

Conducted Emission:

±1.8dB

Bandwidth:

±5%

Frequency Tolerance:

±5%

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: [email protected]
Page 22 of 24

REPORT No.SZ22100161W17
Annex B Testing Laboratory Information

1. Identification of the Responsible Testing Laboratory

Laboratory Name:
Laboratory Address:
Telephone: Facsimile:

Shenzhen Morlab Communications Technology Co., Ltd. FL.3, Building A, FeiYang Science Park, No.8 LongChang Road, Block 67, BaoAn District, ShenZhen, GuangDong Province, P. R. China +86 755 36698555 +86 755 36698525

2. Identification of the Responsible Testing Location

Name: Address:

Shenzhen Morlab Communications Technology Co., Ltd. FL.3, Building A, FeiYang Science Park, No.8 LongChang Road, Block 67, BaoAn District, ShenZhen, GuangDong Province, P. R. China

3. Facilities and Accreditations

All measurement facilities used to collect the measurement data are located at FL.3, Building A, FeiYang Science Park, Block 67, BaoAn District, Shenzhen, 518101 P. R. China. The test site is constructed in conformance with the requirements of ANSI C63.10-2013 and CISPR Publication 22; the FCC designation number is CN1192, the test firm registration number is 226174.

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: [email protected]
Page 23 of 24

REPORT No.SZ22100161W17

4. Test Equipments Utilized

4.1 Test Equipments

Equipment Name

Serial No.

Receiver

MY54130016

Test Antenna Bi-Log

9163-519

Test Antenna Loop

1520-022

Anechoic Chamber

N/A

Temperature Chamber

12108015

Type N9038A VULB 9163 FMZB1519 9m*6m*6m DTL-003S101

Manufacturer Cal. Date Due Date

Agilent

2022.07.06 2023.07.05

Schwarzbeck 2022.05.25 2025.05.24

Schwarzbeck 2022.02.11 2025.02.10

CRT

2020.01.06 2023.01.05

YOMA

2022.10.10 2023.10.09

4.2 Conducted Emission Test Equipments

Equipment Name

Serial No.

Type

Receiver

MY56400093 N9038A

LISN

812744

NSLK 8127

Pulse Limiter VTSD 9561

VTSD

(10dB)

F-B #206

9561-F

Coaxial

Cable(BNC)

CB01

EMC01

(30MHz-26GHz)

Notebook computer

20210357

P144G

Manufacturer KEYSIGHT Schwarzbeck
Schwarzbeck

Cal. Date Due Date 2022.03.03 2023.03.02 2022.03.03 2023.03.02
2022.07.06 2023.07.05

Morlab

N/A

N/A

DELL

N/A

N/A

4.3 Test Software Utilized Model
MORLAB EMCR V1.2 TS+ -[JS32-CE]
PMM Emission Suite

Software Version Version 1.0
Version 2.5.0.0 Version 2.02

Manufacturer MORLAB Tonscend narda