DEKRA Testing and Certification, S.A.U.

17-76874RRF.001A2

Pietro Fiorentini Spa SSMICON250 Ultrasonic gas meter 2BB84-SSMICON250 2BB84SSMICON250 ssmicon250

PDF Viewing Options

Not Your Device? Search For Manuals or Datasheets below:


File Info : application/pdf, 70 Pages, 5.64MB

Document DEVICE REPORTGetApplicationAttachment.html?id=8365412
DEKRA Testing and Certification, S.A.U. Parque Tecnológico de Andalucía, c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España C.I.F. A29507456
ISED CABid: ES1909
Lab. Company Number: 4621A
Test Report
USA FCC Part 15.247, 15.209 CANADA RSS-247, RSS-Gen

(*) Identification of item tested

Ultrasonic gas meter

Test Report No: 76874RRF.001A2

(*) Trademark

Pietro Fiorentini S.p.a

(*) Model and /or type reference

SSM-iCON250-U7-NTC-004

Other identification of the product (*) Features Applicant Test method requested, standard
Summary Approved by (name / position & signature) Date of issue Report template No

FCC ID: 2BB84-SSMICON250 IC: 31434-SSMICON250

Features: Bluetooth LE HW version: 2.0 SW version: 1.0

Pietro Fiorentini S.p.a Via Enrico Fermi 8/10, 36057 Arcugnano (VI) - ITALY

USA FCC Part 15.247 (10-1-21 Edition): Operation within the bands 902 - 928 MHz, 2400 -2483.5 MHz, and 5725 - 5850 MHz. USA FCC Part 15.209 (10-1-21 Edition): Radiated emission limits; general requirements. CANADA RSS-247 Issue 3 (August 2023). CANADA RSS-Gen Issue 5 amendment 2 (February 2021). Guidance for Performing Compliance Measurements on Digital Transmission System, Frequency Hopping Spread Spectrum System, and Hybrid Systems Devices Operating Under Section 15.247 of the FCC Rules. 558074 D01 Meas Guidance v05r02 dated April 2, 2019.
ANSI C63.10-2013: American National Standard for Testing Unlicensed Wireless Devices.

IN COMPLIANCE

José Manuel Gómez Galván EMC Consumer & RF Lab. Manager

Firmado digitalmente por 53680346W JOSE MANUEL GOMEZ (C:A29507456)

2025-01-30
FDT08_24 (*) "Data provided by the client"

Report No: 76874RRF.001A2

2025-01-30

DEKRA Testing and Certification, S.A.U. Parque Tecnológico de Andalucía, c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España C.I.F. A29507456
Index
INDEX ...........................................................................................................................................................................2 ACRONYMS .................................................................................................................................................................3 COMPETENCES AND GUARANTEES .......................................................................................................................3 GENERAL CONDITIONS .............................................................................................................................................4 UNCERTAINTY ............................................................................................................................................................4 DATA PROVIDED BY THE CLIENT ............................................................................................................................4 USAGE OF SAMPLES .................................................................................................................................................5 TEST SAMPLE DESCRIPTION ...................................................................................................................................6 IDENTIFICATION OF THE CLIENT .............................................................................................................................8 TESTING PERIOD AND PLACE ..................................................................................................................................8 DOCUMENT HISTORY ................................................................................................................................................8 ENVIRONMENTAL CONDITIONS ...............................................................................................................................8 REMARKS AND COMMENTS .....................................................................................................................................9 TESTING VERDICTS .................................................................................................................................................10 SUMMARY..................................................................................................................................................................10 APPENDIX A: TEST RESULTS. BLUETOOTH LOW ENERGY 5.0 .........................................................................11

Report No: 76874RRF.001A2

Page 2 of 70

2025-01-30

DEKRA Testing and Certification, S.A.U. Parque Tecnológico de Andalucía, c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España C.I.F. A29507456

Acronyms
Acronym ID BW Detector Ebw Equipment Freq Freq Rng Inband Peak Lvl Lvl MP Mod Mode Occ Ch BW PSD PeakPower Pol Port Unwanted Freq Unwanted Lvl

Acronym Description Bandwidth Detector used Emission Bandwidth Equipment Type Frequency Frequency Range Inband Peak Level Level Measurement Point Modulation MIMO Mode Occupied Channel Bandwidth Power Spectrum Density Maximum Peak Conducted Output Power Polarization Active Port Unwanted Emissions Frequency Unwanted Emissions Level

Competences and guarantees
DEKRA Testing and Certification S.A.U. is a testing laboratory accredited by the National Accreditation Body (ENAC -Entidad Nacional de Acreditación), to perform the tests indicated in the Certificate No. 51/LE 147.
DEKRA Testing and Certification S.A.U. is an FCC-recognized accredited testing laboratory with appropriate scope of accreditation that covers the performed tests in this report.
DEKRA Testing and Certification S.A.U. is an ISED-recognized accredited testing laboratory, CABid: ES1909, Company Number: 4621A, with the appropriate scope of accreditation that covers the performed tests in this report.
In order to assure the traceability to other national and international laboratories, DEKRA Testing and Certification S.A.U. has a calibration and maintenance program for its measurement equipment.
DEKRA Testing and Certification S.A.U. guarantees the reliability of the data presented in this report, which is the result of the measurements and the tests performed to the item under test on the date and under the conditions stated on the report and, it is based on the knowledge and technical facilities available at DEKRA Testing and Certification S.A.U. at the time of performance of the test.
DEKRA Testing and Certification S.A.U. is liable to the client for the maintenance of the confidentiality of all information related to the item under test and the results of the test.
The results presented in this Test Report apply only to the particular item under test established in this document.
IMPORTANT: No parts of this report may be reproduced or quoted out of context, in any form or by any means, except in full, without the previous written permission of DEKRA Testing and Certification S.A.U.

Report No: 76874RRF.001A2

Page 3 of 70

2025-01-30

DEKRA Testing and Certification, S.A.U. Parque Tecnológico de Andalucía, c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España C.I.F. A29507456
General conditions
1. This report is only referred to the item that has undergone the test. 2. This report does not constitute or imply on its own an approval of the product by the Certification Bodies or
competent Authorities. 3. This document is only valid if complete; no partial reproduction can be made without previous written
permission of DEKRA Testing and Certification S.A.U. 4. This test report cannot be used partially or in full for publicity and/or promotional purposes without previous
written permission of DEKRA Testing and Certification S.A.U. and the Accreditation Bodies.
Uncertainty
Uncertainty (factor k=2) was calculated according to the DEKRA Testing and Certification S.A.U. internal document PODT000. The total uncertainty of the measurement system for the radiated emissions of EUT from 30 MHz to 1 GHz is: Measurement uncertainty  ± 5,35 dB with factor (k = 2).
The total uncertainty of the measurement system for the radiated emissions of EUT from 1 GHz to 17 GHz is: Measurement uncertainty  ± 4,32 dB with factor (k = 2).
The total uncertainty of the measurement system for the radiated emissions of EUT from 17 GHz to 26 GHz is: Measurement uncertainty  ± 5,51 dB with factor (k = 2).
The total uncertainty of the measurement system for the conducted testing of EUT is: RF Peak Output Power: Measurement uncertainty  ± 0,80 dB RF Average Output Power: Measurement uncertainty  ± 0,99 dB Power Spectral Density: Measurement uncertainty  ± 0,99 dB 6dB Bandwidth: Measurement uncertainty  ± 2,84 % Occupied Channel Bandwidth: Measurement uncertainty  ± 1,17 % Conducted Band-edge spurious emissions: Measurement uncertainty  ± 1,76 dB
Data provided by the client
The following data has been provided by the client:
1. Information relating to the description of the sample ("Identification of the item tested", "Trademark", "Model and/or type reference tested").
2. The sample consists of a Ultrasonic gas meter. Ultrasonic gas meter for residential and light industrial environment; local communication by BLE interface; remote communication by LTE catM/NB modem in SSM-COM module.
DEKRA Testing and Certification S.A.U. declines any responsibility with respect to the information provided by the client and that may affect the validity of results.

Report No: 76874RRF.001A2

Page 4 of 70

2025-01-30

DEKRA Testing and Certification, S.A.U. Parque Tecnológico de Andalucía, c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España C.I.F. A29507456
Usage of samples
Samples undergoing test have been selected by: The client.

Id S/01

Control Number Description

75903_1.1

Ultrasonic gas meter

Model
SSM-iCON250-U7NTC-004

Serial Nº
--

Date of Reception Application

2023-07-05

Element Under Test

S/01 S/02 S/02 S/02

75208B_13.1 75208B_13.1 75208B_7.1 75903_2.1

Device Electronic
Device Electronic
Battery Lithium
Ultrasonic gas meter

--

--

--

--

ER34615M

--

SSM-iCON250-U7- -NTC-004

2023-05-02 2023-05-02 2023-03-30 2023-07-05

Auxiliary Element
Element Under Test
Element Under Test
Element Under Test

S/02

75903_3.1

Module circuit -board with display Conducted

Notes referenced to samples during the project: Id

Type

2023-08-02

Element Under Test

S/01

Radiated

S/02

Conducted

Report No: 76874RRF.001A2

Page 5 of 70

2025-01-30

DEKRA Testing and Certification, S.A.U. Parque Tecnológico de Andalucía, c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España C.I.F. A29507456

Test sample description

Ports..................................... :

Port name and description

Cable

Specified Attached max during test
length [m]

Shielded

Coupled to
patient(3)

.......

.......

[ ]

[ ]

[ ]

Supplementary information to the ports..................................... :
Rated power supply ....................:

....... Voltage and Frequency

Reference poles

L1

L2 L3

N

PE

[ ] AC: .......

[] [] [] [] []

[ ] AC: .......

[] [] [] [] []

DC: 3.6V LiSOCl Primary battery, non-rechargeable, non[X]
replaceable

[ ] DC: .......

Rated Power ...............................: Clock frequencies........................: Other parameters ........................: Software version .........................: Hardware version ........................: Dimensions in cm (W x H x D) ....: Mounting position ........................:

....... 38.4MHz (BLE chipset) ....... ....... ....... 22,5X15X12,5 [ ] Table top equipment [X] Wall/Ceiling mounted equipment

[ ] Floor standing equipment

[ ] Hand-held equipment

[ ] Other: .......

Modules/parts ..............................:

Module/parts of test item .......

Type .......

Manufacturer .......

Accessories (not part of the test item) ............................................:

Description .......

Type .......

Manufacturer .......

Description

File name Issue date

Report No: 76874RRF.001A2

Page 6 of 70

2025-01-30

DEKRA Testing and Certification, S.A.U. Parque Tecnológico de Andalucía, c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España C.I.F. A29507456

Documents as provided by the applicant ......................................:

BLE Chipset datasheet

Antenna datasheet Modem datasheet

(3) Only for Medical Equipment

.......

EFR32BG2 2C112 Wireless Gecko SoC Data Sheet

June 2021 rev.1.1

FM13C25L- 14/03/2023 0050S

Quectel_BG 95_Series_ LPWA_Spe cification_V 1.6-1

rev. 1.6

.......

.......

Report No: 76874RRF.001A2

Page 7 of 70

2025-01-30

DEKRA Testing and Certification, S.A.U. Parque Tecnológico de Andalucía, c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España C.I.F. A29507456
Identification of the client
Pietro Fiorentini S.p.a Via Enrico Fermi 8/10, 36057 Arcugnano (VI) - ITALY

Testing period and place

Test Location Date (start) Date (finish)

DEKRA Testing and Certification S.A.U. 2023-09-30 2023-10-02

Document history

Report number 76874RRF.001

Date 2023-10-27

76874RRF.001A1 2024-01-19

76874RRF.001A2 2025-01-30

First release.

Description

It is modified due to update of information and features.
This modification test report cancels and replaces the test report 76874RRF.001

It is modified due to typos and missing information.
This modification test report cancels and replaces the test report 76874RRF.001A1

Environmental conditions
In the control chamber, the following limits were not exceeded during the test:

Temperature Relative humidity

Min. = 15 ºC Max. = 35 ºC
Min. = 20 % Max. = 75 %

In the semianechoic chamber, the following limits were not exceeded during the test.

Temperature Relative humidity

Min. = 15 ºC Max. = 35 ºC
Min. = 20 % Max. = 75 %

In the chamber for conducted measurements, the following limits were not exceeded during the test:

Temperature Relative humidity

Min. = 15 ºC Max. = 35 ºC
Min. = 20 % Max. = 75 %

Report No: 76874RRF.001A2

Page 8 of 70

2025-01-30

DEKRA Testing and Certification, S.A.U. Parque Tecnológico de Andalucía, c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España C.I.F. A29507456
Remarks and comments
The tests have been performed by the technical personnel: Francisco Lopez Chamorro and José Manuel Jiménez González. Used instrumentation:

Control No. 6791
6792

Equipment

Model

Manufacturer

SEMIANECHOIC ABSORBER FACT 3 200 STP LINED CHAMBER

SHIELDED ROOM

S101

ETS LINDGREN ETS LINDGREN

Next Calibration N/A
N/A

6143 6144 7817 4611
3783 4848 6793

HYBRID BILOG ANTENNA 3142E 30MHz-6GHz

PRE-AMPLIFIER 10MHz-6GHz

G>40dB BLNA 0160-01N

EMI TEST RECEIVER 2Hz- ESW44 44GHz

HORN ANTENNA 1-18GHz

BBHA 9120 D

PRE-AMPLIFIER 1GHz-18GHz
SOFTWARE FOR TESTING
SHIELDED ROOM

G>30dB BLMA 0118-3A EMC/RF EMC32
S101

ETS LINDGREN 2023-10-29

BONN ELEKTRONIK

2024-07-25

ROHDE AND 2023-12-30 SCHWARZ

SCHWARZBECK MESSELEKTRONIK

2026-01-16

BONN ELEKTRONIK

2023-12-29

ROHDE AND N/A SCHWARZ

ETS LINDGREN N/A

4657
8856 7796 8848 7798

HORN ANTENNA 18-40GHz

BBHA 9170

PRE-AMPLIFIER 18GHz ­ 40GHZ

G>30dB BLMA 1840-4A

EXTENSION FOR OPEN OSP-B157Wx SWITCH UNIT UP TO 40GHz

OPEN SWITCH UNIT UP TO 7.5 OSP-B157W8

GHz

PLUS

SOFTWARE FOR RF TESTING WMS32

SCHWARZBECK MESSELEKTRONIK

2026-06-12

BONN ELEKTRONIK

2023-11-02

ROHDE AND 2024-03-16 SCHWARZ

ROHDE SCHWARZ

& 2024-12-21

ROHDE AND N/A SCHWARZ

Report No: 76874RRF.001A2

Page 9 of 70

2025-01-30

DEKRA Testing and Certification, S.A.U. Parque Tecnológico de Andalucía, c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España C.I.F. A29507456
Testing verdicts
Fail Inconclusive Not applicable Not measured Pass

F I N/A N/M P

Summary

Bluetooth Low Energy

FCC PART 15 PARAGRAPH/ RSS-247

Requirement ­ Test case

FCC 15.247 (a)(2) / RSS-247 5.2. (a)

6 dB Bandwidth

Verdict Remark P

FCC 15.247 (b) / RSS-247 5.4. (d)

Maximum output power and

P

antenna gain

FCC 15.247 (d) / RSS-247 5.5.

Band-edge emissions compliance

P

(Transmitter)

FCC 15.247 (e) / RSS-247 5.2. (b)

Power spectral density

P

FCC 15.247 (d) / RSS-247 5.5.

Emission limitations radiated P
(Transmitter)

Supplementary information and remarks:

None

Report No: 76874RRF.001A2

Page 10 of 70

2025-01-30

DEKRA Testing and Certification, S.A.U. Parque Tecnológico de Andalucía, c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España C.I.F. A29507456
Appendix A: Test results. Bluetooth Low Energy 5.0

Report No: 76874RRF.001A2

Page 11 of 70

2025-01-30

DEKRA Testing and Certification, S.A.U. Parque Tecnológico de Andalucía, c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España C.I.F. A29507456
INDEX
TEST CONDITIONS ...................................................................................................................................................13
TEST CASES DETAILS .............................................................................................................................................16
FCC 47 CFR PART 15.247 / RSS-247 .....................................................................................................................16
99dBw Occupied Channel Bandwidth 99% ........................................................................................................16 RSS-247 5.2 (a) / FCC 15.247 (a) (2) [6dBw] 6 dB Bandwidth ..........................................................................23 RSS-247 5.2 (b) / FCC 15.247 (e) [Psd] Power spectral density .......................................................................30 RSS-247 5.4 (d) / FCC 15.247 (b) (3) [Pkcp] Maximum Peak Conducted output power ...................................37 RSS-247 5.5 / FCC 15.247 (d) [Bndedge] Band-edge emissions compliance (Transmitter) .............................44 RSS-247 5.5 / FCC 15.247 (d) [RSE] Emission limitations radiated (Transmitter) ............................................49

Report No: 76874RRF.001A2

Page 12 of 70

2025-01-30

DEKRA Testing and Certification, S.A.U. Parque Tecnológico de Andalucía, c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España C.I.F. A29507456
TEST CONDITIONS
(*): Data provided by the client.

POWER SUPPLY (*): Vnominal: Type of Power Supply:

3.6V LiSOCl Primary battery, non-rechargeable, non-replaceable V Battery

ANTENNA (*): Type of Antenna: Maximum Declared Antenna Gain:

Custom Wideband passive antenna -5dBi

TEST FREQUENCIES (*):

Modulation
BTLE GFSK BTLE GFSK

Data rates
1M 1 Mbit/s 2M 2 Mbit/s

Low Channel:
2402 MHz 2402 MHz

Middle Channel High Channel

2440 MHz

2480 MHz

2440 MHz

2480 MHz

During transmitter test the EUT was controlled by a SW tool provided by the client to operate in a continuous transmit mode on the modulation schemes and test channels as required.
CONDUCTED MEASUREMENTS:
The equipment under test was set up in a shielded room and it is connected to the TS8997 using a low loss RF cable. The reading of the spectrum analyser is corrected taking into account the cable loss.

RADIATED MEASUREMENTS:
All radiated tests were performed in a semi-anechoic chamber. The measurement antenna (Bilog antenna for the range between 30 MHz to 1000 MHz and 1 GHz-17 GHz Double ridge horn antenna) is situated at a distance of 3 m and at a distance of 1.5 m for the frequency range 17 GHz-26 GHz (17 GHz-40 GHz horn antenna).
For radiated emissions in the range 17 GHz-26 GHz that is performed at a distance closer than the specified distance, an inverse proportionality factor of 20 dB per decade is used to normalize the measured data for determining compliance.
The equipment under test was set up on a non-conductive platform above the ground plane and the situation and orientation was varied to find the maximum radiated emission. It was also rotated 360º and the antenna height (Bilog antenna and Double ridge horn antenna) was varied from 1 to 4 meters to find the maximum radiated emission.
Measurements were made in both horizontal and vertical planes of polarization. A resolution bandwidth/video bandwidth of 100 kHz / 300 kHz was used for frequencies below 1 GHz and 1 MHz / 3 MHz for frequencies above 1 GHz.

Report No: 76874RRF.001A2

Page 13 of 70

2025-01-30

DEKRA Testing and Certification, S.A.U. Parque Tecnológico de Andalucía, c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España C.I.F. A29507456
Radiated measurements setup from 30 MHz to 1 GHz:

Radiated measurements setup from 1 GHz to 17 GHz:

Report No: 76874RRF.001A2

Page 14 of 70

2025-01-30

DEKRA Testing and Certification, S.A.U. Parque Tecnológico de Andalucía, c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España C.I.F. A29507456
Radiated measurements setup f > 17 GHz:

Report No: 76874RRF.001A2

Page 15 of 70

2025-01-30

DEKRA Testing and Certification, S.A.U. Parque Tecnológico de Andalucía, c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España C.I.F. A29507456
TEST CASES DETAILS

FCC 47 CFR Part 15.247 / RSS-247 99dBw Occupied Channel Bandwidth 99%

Modulation: BTLE 5.0 (GFSK 1 Mbit/s) Results
Equipment
Digital Transmission System (DTS)

BW (MHz) 1

Freq (MHz) 2402.00000 2440.00000 2480.00000

Port 1

Occ Ch BW (MHz) 1.020 1.020 1.020

Modulation: BTLE 5.0 (GFSK 2 Mbit/s) Results
Equipment
Digital Transmission System (DTS)

BW (MHz) 2

Freq (MHz) 2402.00000 2440.00000 2480.00000

Port 1

Occ Ch BW (MHz) 2.059 2.059 2.059

Verdict Pass

Report No: 76874RRF.001A2

Page 16 of 70

2025-01-30

DEKRA Testing and Certification, S.A.U. Parque Tecnológico de Andalucía, c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España C.I.F. A29507456

Attachments

Equipment Type = Digital Transmission System (DTS) Bandwidth MHz = 1

Modulation = BTLE 5.0 (GFSK 1 Mbit/s)

Frequency MHz = 2402.00000

MIMO Mode = SISO

Active Port = 1

Images:

Report No: 76874RRF.001A2

Page 17 of 70

2025-01-30

DEKRA Testing and Certification, S.A.U. Parque Tecnológico de Andalucía, c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España C.I.F. A29507456

Equipment Type = Digital Transmission System (DTS) Bandwidth MHz = 1

Modulation = BTLE 5.0 (GFSK 1 Mbit/s)

Frequency MHz = 2440.00000

MIMO Mode = SISO

Active Port = 1

Images:

Report No: 76874RRF.001A2

Page 18 of 70

2025-01-30

DEKRA Testing and Certification, S.A.U. Parque Tecnológico de Andalucía, c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España C.I.F. A29507456

Equipment Type = Digital Transmission System (DTS) Bandwidth MHz = 1

Modulation = BTLE 5.0 (GFSK 1 Mbit/s)

Frequency MHz = 2480.00000

MIMO Mode = SISO

Active Port = 1

Images:

Report No: 76874RRF.001A2

Page 19 of 70

2025-01-30

DEKRA Testing and Certification, S.A.U. Parque Tecnológico de Andalucía, c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España C.I.F. A29507456

Attachments

Equipment Type = Digital Transmission System (DTS) Bandwidth MHz = 2

Modulation = BTLE 5.0 (GFSK 2 Mbit/s)

Frequency MHz = 2402.00000

MIMO Mode = SISO

Active Port = 1

Images:

Report No: 76874RRF.001A2

Page 20 of 70

2025-01-30

DEKRA Testing and Certification, S.A.U. Parque Tecnológico de Andalucía, c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España C.I.F. A29507456

Equipment Type = Digital Transmission System (DTS) Bandwidth MHz = 2

Modulation = BTLE 5.0 (GFSK 2 Mbit/s)

Frequency MHz = 2440.00000

MIMO Mode = SISO

Active Port = 1

Images:

Report No: 76874RRF.001A2

Page 21 of 70

2025-01-30

DEKRA Testing and Certification, S.A.U. Parque Tecnológico de Andalucía, c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España C.I.F. A29507456

Equipment Type = Digital Transmission System (DTS) Bandwidth MHz = 2

Modulation = BTLE 5.0 (GFSK 2 Mbit/s)

Frequency MHz = 2480.00000

MIMO Mode = SISO

Active Port = 1

Images:

Report No: 76874RRF.001A2

Page 22 of 70

2025-01-30

DEKRA Testing and Certification, S.A.U. Parque Tecnológico de Andalucía, c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España C.I.F. A29507456

RSS-247 5.2 (a) / FCC 15.247 (a) (2) [6dBw] 6 dB Bandwidth

Limits The minimum 6 dB bandwidth shall be at least 500 kHz.

Modulation: BTLE 5.0 (GFSK 1 Mbit/s)

Results BW (MHz)
1

Freq (MHz) 2402.00000 2440.00000 2480.00000

Port 1

Ebw (MHz) 0.693 0.713 0.693

Modulation: BTLE 5.0 (GFSK 2 Mbit/s) Results

BW (MHz)

Freq (MHz)

Port

Ebw (MHz)

2402.00000

1.426

2

2440.00000

1

1.426

2480.00000

1.426

Verdict Pass

Report No: 76874RRF.001A2

Page 23 of 70

2025-01-30

DEKRA Testing and Certification, S.A.U. Parque Tecnológico de Andalucía, c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España C.I.F. A29507456

Attachments

Bandwidth MHz = 1

Modulation = BTLE 5.0 (GFSK 1 Mbit/s)

Frequency MHz = 2402.00000 MIMO Mode = SISO

Active Port = 1

Images:

Report No: 76874RRF.001A2

Page 24 of 70

2025-01-30

DEKRA Testing and Certification, S.A.U. Parque Tecnológico de Andalucía, c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España C.I.F. A29507456

Bandwidth MHz = 1

Modulation = BTLE 5.0 (GFSK 1 Mbit/s)

Frequency MHz = 2440.00000 MIMO Mode = SISO

Active Port = 1

Images:

Report No: 76874RRF.001A2

Page 25 of 70

2025-01-30

DEKRA Testing and Certification, S.A.U. Parque Tecnológico de Andalucía, c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España C.I.F. A29507456

Bandwidth MHz = 1

Modulation = BTLE 5.0 (GFSK 1 Mbit/s)

Frequency MHz = 2480.00000 MIMO Mode = SISO

Active Port = 1

Images:

Report No: 76874RRF.001A2

Page 26 of 70

2025-01-30

DEKRA Testing and Certification, S.A.U. Parque Tecnológico de Andalucía, c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España C.I.F. A29507456

Attachments

Bandwidth MHz = 2

Modulation = BTLE 5.0 (GFSK 2 Mbit/s)

Frequency MHz = 2402.00000 MIMO Mode = SISO

Active Port = 1

Images:

Report No: 76874RRF.001A2

Page 27 of 70

2025-01-30

DEKRA Testing and Certification, S.A.U. Parque Tecnológico de Andalucía, c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España C.I.F. A29507456

Bandwidth MHz = 2

Modulation = BTLE 5.0 (GFSK 2 Mbit/s)

Frequency MHz = 2440.00000 MIMO Mode = SISO

Active Port = 1

Images:

Report No: 76874RRF.001A2

Page 28 of 70

2025-01-30

DEKRA Testing and Certification, S.A.U. Parque Tecnológico de Andalucía, c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España C.I.F. A29507456

Bandwidth MHz = 2

Modulation = BTLE 5.0 (GFSK 2 Mbit/s)

Frequency MHz = 2480.00000 MIMO Mode = SISO

Active Port = 1

Images:

Report No: 76874RRF.001A2

Page 29 of 70

2025-01-30

DEKRA Testing and Certification, S.A.U. Parque Tecnológico de Andalucía, c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España C.I.F. A29507456

RSS-247 5.2 (b) / FCC 15.247 (e) [Psd] Power spectral density

Limits
For digitally modulated systems, the power spectral density conducted from the intentional radiator to the antenna shall not be greater than 8 dBm in any 3 kHz band during any time interval of continuous transmission.

Results Modulation: BTLE 5.0 (GFSK 1 Mbit/s)
Equipment
Digital Transmission System (DTS)

BW (MHz) 1

Freq (MHz) 2402.00000 2440.00000 2480.00000

Port 1

PSD (dBm) -9.52 -9.12 -9.37

Modulation: BTLE 5.0 (GFSK 2 Mbit/s) Equipment
Digital Transmission System (DTS)

BW (MHz) 2

Freq (MHz) 2402.00000 2440.00000 2480.00000

Port 1

PSD (dBm) -13.21 -12.84 -13.09

Verdict Pass

Report No: 76874RRF.001A2

Page 30 of 70

2025-01-30

DEKRA Testing and Certification, S.A.U. Parque Tecnológico de Andalucía, c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España C.I.F. A29507456

Attachments

Equipment Type = Digital Transmission System (DTS) Bandwidth MHz = 1

Modulation = BTLE 5.0 (GFSK 1 Mbit/s)

Frequency MHz = 2402.00000

MIMO Mode = SISO

Active Port = 1

Images:

Report No: 76874RRF.001A2

Page 31 of 70

2025-01-30

DEKRA Testing and Certification, S.A.U. Parque Tecnológico de Andalucía, c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España C.I.F. A29507456

Equipment Type = Digital Transmission System (DTS) Bandwidth MHz = 1

Modulation = BTLE 5.0 (GFSK 1 Mbit/s)

Frequency MHz = 2440.00000

MIMO Mode = SISO

Active Port = 1

Images:

Report No: 76874RRF.001A2

Page 32 of 70

2025-01-30

DEKRA Testing and Certification, S.A.U. Parque Tecnológico de Andalucía, c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España C.I.F. A29507456

Equipment Type = Digital Transmission System (DTS) Bandwidth MHz = 1

Modulation = BTLE 5.0 (GFSK 1 Mbit/s)

Frequency MHz = 2480.00000

MIMO Mode = SISO

Active Port = 1

Images:

Report No: 76874RRF.001A2

Page 33 of 70

2025-01-30

DEKRA Testing and Certification, S.A.U. Parque Tecnológico de Andalucía, c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España C.I.F. A29507456

Attachments

Equipment Type = Digital Transmission System (DTS) Bandwidth MHz = 2

Modulation = BTLE 5.0 (GFSK 2 Mbit/s)

Frequency MHz = 2402.00000

MIMO Mode = SISO

Active Port = 1

Images:

Report No: 76874RRF.001A2

Page 34 of 70

2025-01-30

DEKRA Testing and Certification, S.A.U. Parque Tecnológico de Andalucía, c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España C.I.F. A29507456

Equipment Type = Digital Transmission System (DTS) Bandwidth MHz = 2

Modulation = BTLE 5.0 (GFSK 2 Mbit/s)

Frequency MHz = 2440.00000

MIMO Mode = SISO

Active Port = 1

Images:

Report No: 76874RRF.001A2

Page 35 of 70

2025-01-30

DEKRA Testing and Certification, S.A.U. Parque Tecnológico de Andalucía, c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España C.I.F. A29507456

Equipment Type = Digital Transmission System (DTS) Bandwidth MHz = 2

Modulation = BTLE 5.0 (GFSK 2 Mbit/s)

Frequency MHz = 2480.00000

MIMO Mode = SISO

Active Port = 1

Images:

Report No: 76874RRF.001A2

Page 36 of 70

2025-01-30

DEKRA Testing and Certification, S.A.U. Parque Tecnológico de Andalucía, c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España C.I.F. A29507456

RSS-247 5.4 (d) / FCC 15.247 (b) (3) [Pkcp] Maximum Peak Conducted output power

Limits
For systems using digital modulation in the 2400-2483.5 MHz band: 1 watt (30 dBm). The e.i.r.p. shall not exceed 4 W (36 dBm) (Canada). The maximum peak conducted output power level in the fundamental emission was measured using the method according to point 11.9.1.1 "RBW  DTS bandwidth" of ANSI C.63.10-2013.

Modulation: BTLE 5.0 (GFSK 1 Mbit/s) Results

Equipment

BW (MHz)

Digital Transmission System (DTS)

1

Digital Transmission System (DTS)

1

Digital Transmission System (DTS)

1

Freq (MHz) 2402.00000 2440.00000 2480.00000

Port 1 1 1

PeakPower (dBm) 0.4020
0.7480
0.5180

EIRP Power (dBm) -4,598
-4,252
-4,482

Modulation: BTLE 5.0 (GFSK 2 Mbit/s)

Equipment

BW (MHz)

Digital Transmission System (DTS)

2

Freq (MHz)
2402.00000 2440.00000 2480.00000

Port
1 1 1

PeakPower (dBm) 0.4530 0.8270 0.5890

EIRP Power (dBm) -4,547 -4,173 -4,411

Verdict Pass

Report No: 76874RRF.001A2

Page 37 of 70

2025-01-30

DEKRA Testing and Certification, S.A.U. Parque Tecnológico de Andalucía, c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España C.I.F. A29507456

Attachments

Equipment Type = Digital Transmission System (DTS) Bandwidth MHz = 1

Modulation = BTLE 5.0 (GFSK 1 Mbit/s)

Frequency MHz = 2402.00000

MIMO Mode = SISO

Active Port = 1

Images:

Report No: 76874RRF.001A2

Page 38 of 70

2025-01-30

DEKRA Testing and Certification, S.A.U. Parque Tecnológico de Andalucía, c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España C.I.F. A29507456

Equipment Type = Digital Transmission System (DTS) Bandwidth MHz = 1

Modulation = BTLE 5.0 (GFSK 1 Mbit/s)

Frequency MHz = 2440.00000

MIMO Mode = SISO

Active Port = 1

Images:

Report No: 76874RRF.001A2

Page 39 of 70

2025-01-30

DEKRA Testing and Certification, S.A.U. Parque Tecnológico de Andalucía, c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España C.I.F. A29507456

Equipment Type = Digital Transmission System (DTS) Bandwidth MHz = 1

Modulation = BTLE 5.0 (GFSK 1 Mbit/s)

Frequency MHz = 2480.00000

MIMO Mode = SISO

Active Port = 1

Images:

Report No: 76874RRF.001A2

Page 40 of 70

2025-01-30

DEKRA Testing and Certification, S.A.U. Parque Tecnológico de Andalucía, c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España C.I.F. A29507456

Equipment Type = Digital Transmission System (DTS) Bandwidth MHz = 2

Modulation = BTLE 5.0 (GFSK 2 Mbit/s)

Frequency MHz = 2402.00000

MIMO Mode = SISO

Active Port = 1

Images:

Report No: 76874RRF.001A2

Page 41 of 70

2025-01-30

DEKRA Testing and Certification, S.A.U. Parque Tecnológico de Andalucía, c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España C.I.F. A29507456

Equipment Type = Digital Transmission System (DTS) Bandwidth MHz = 2

Modulation = BTLE 5.0 (GFSK 2 Mbit/s)

Frequency MHz = 2440.00000

MIMO Mode = SISO

Active Port = 1

Images:

Report No: 76874RRF.001A2

Page 42 of 70

2025-01-30

DEKRA Testing and Certification, S.A.U. Parque Tecnológico de Andalucía, c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España C.I.F. A29507456

Equipment Type = Digital Transmission System (DTS) Bandwidth MHz = 2

Modulation = BTLE 5.0 (GFSK 2 Mbit/s)

Frequency MHz = 2480.00000

MIMO Mode = SISO

Active Port = 1

Images:

Report No: 76874RRF.001A2

Page 43 of 70

2025-01-30

DEKRA Testing and Certification, S.A.U. Parque Tecnológico de Andalucía, c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España C.I.F. A29507456
RSS-247 5.5 / FCC 15.247 (d) [Bndedge] Band-edge emissions compliance (Transmitter)
Limits In any 100 kHz bandwidths outside the frequency band in which the intentional radiator is operating, the radio frequency power that is produced by the intentional radiator shall be at least 20 dB below that in the 100 kHz bandwidth within the band that contains the highest level of the desired power, based on either an RF conducted or a radiated measurement, provided the transmitter demonstrates compliance with the peak conducted power limits. If the transmitter complies with the conducted power limits based on the use of RMS averaging over a time interval, the attenuation required under this paragraph shall be 30 dB instead of 20 dB.
Modulation: BTLE 5.0 (GFSK 1 Mbit/s)
Results Radiated measurements were used to show compliance with the limits in the restricted bands 2.31-2.39 GHz and 2.4835-2.5 GHz.
Modulation: BTLE 5.0 (GFSK 2 Mbit/s)
Results Radiated measurements were used to show compliance with the limits in the restricted bands 2.31-2.39 GHz and 2.4835-2.5 GHz.
Verdict Pass

Report No: 76874RRF.001A2

Page 44 of 70

2025-01-30

DEKRA Testing and Certification, S.A.U. Parque Tecnológico de Andalucía, c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España C.I.F. A29507456

Attachments

Equipment Type = Digital Transmission System (DTS) Bandwidth MHz = 1

Modulation = BTLE 5.0 (GFSK 1 Mbit/s)

Frequency MHz = 2402.00000

MIMO Mode = SISO

Measurement Point = 1

Active Port = 1

Images:

Equipment Type = Digital Transmission System (DTS) Bandwidth MHz = 2

Modulation = BTLE 5.0 (GFSK 2 Mbit/s)

Frequency MHz = 2402.00000

MIMO Mode = SISO

Measurement Point = 1

Active Port = 1

Images:

Report No: 76874RRF.001A2

Page 45 of 70

2025-01-30

DEKRA Testing and Certification, S.A.U. Parque Tecnológico de Andalucía, c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España C.I.F. A29507456

Tables:

Spectrum Analyzer Parameters 1 Setting

Instrument Value Target Value

Start Frequency 2.31000 GHz

2.31000 GHz

Stop Frequency 2.40000 GHz

2.40000 GHz

Span

90.000 MHz

90.000 MHz

RBW

100.000 kHz <= 100.000 kHz

VBW

300.000 kHz >= 300.000 kHz

SweepPoints

1800

~ 1800

Sweeptime

113.672 µs

AUTO

Reference Level 10.000 dBm

10.000 dBm

Attenuation

30.000 dB

AUTO

Detector

MaxPeak

MaxPeak

SweepCount

100

100

Filter

3 dB

3 dB

Trace Mode

Max Hold

Max Hold

Sweeptype

FFT

AUTO

Preamp

off

off

Stablemode

Trace

Trace

Stablevalue

0.50 dB

0.50 dB

Spectrum Analyzer Parameters 2 Setting

Instrument Value Target Value

Start Frequency 2.40000 GHz

2.40000 GHz

Stop Frequency 2.48350 GHz

2.48350 GHz

Span

83.500 MHz

83.500 MHz

RBW

100.000 kHz <= 100.000 kHz

VBW

300.000 kHz >= 300.000 kHz

SweepPoints

1670

~ 1670

Sweeptime

94.727 µs

AUTO

Reference Level 10.000 dBm

10.000 dBm

Attenuation

30.000 dB

AUTO

Detector

MaxPeak

MaxPeak

SweepCount

100

100

Filter

3 dB

3 dB

Trace Mode

Max Hold

Max Hold

Sweeptype

FFT

AUTO

Preamp

off

off

Stablemode

Trace

Trace

Stablevalue

0.50 dB

0.50 dB

Report No: 76874RRF.001A2

Page 46 of 70

2025-01-30

DEKRA Testing and Certification, S.A.U. Parque Tecnológico de Andalucía, c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España C.I.F. A29507456

Equipment Type = Digital Transmission System (DTS) Bandwidth MHz = 1

Modulation = BTLE 5.0 (GFSK 1 Mbit/s)

Frequency MHz = 2480.00000

MIMO Mode = SISO

Measurement Point = 1

Active Port = 1

Images:

Equipment Type = Digital Transmission System (DTS) Bandwidth MHz = 2

Modulation = BTLE 5.0 (GFSK 2 Mbit/s)

Frequency MHz = 2480.00000

MIMO Mode = SISO

Measurement Point = 1

Active Port = 1

Images:

Report No: 76874RRF.001A2

Page 47 of 70

2025-01-30

DEKRA Testing and Certification, S.A.U. Parque Tecnológico de Andalucía, c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España C.I.F. A29507456

Tables:

Spectrum Analyzer Parameters 1 Setting

Instrument Value Target Value

Start Frequency 2.31000 GHz

2.31000 GHz

Stop Frequency 2.40000 GHz

2.40000 GHz

Span

90.000 MHz

90.000 MHz

RBW

100.000 kHz <= 100.000 kHz

VBW

300.000 kHz >= 300.000 kHz

SweepPoints

1800

~ 1800

Sweeptime

113.672 µs

AUTO

Reference Level 10.000 dBm

10.000 dBm

Attenuation

30.000 dB

AUTO

Detector

MaxPeak

MaxPeak

SweepCount

100

100

Filter

3 dB

3 dB

Trace Mode

Max Hold

Max Hold

Sweeptype

FFT

AUTO

Preamp

off

off

Stablemode

Trace

Trace

Stablevalue

0.50 dB

0.50 dB

Spectrum Analyzer Parameters 2 Setting

Instrument Value Target Value

Start Frequency 2.40000 GHz

2.40000 GHz

Stop Frequency 2.48350 GHz

2.48350 GHz

Span

83.500 MHz

83.500 MHz

RBW

100.000 kHz <= 100.000 kHz

VBW

300.000 kHz >= 300.000 kHz

SweepPoints

1670

~ 1670

Sweeptime

94.727 µs

AUTO

Reference Level 10.000 dBm

10.000 dBm

Attenuation

30.000 dB

AUTO

Detector

MaxPeak

MaxPeak

SweepCount

100

100

Filter

3 dB

3 dB

Trace Mode

Max Hold

Max Hold

Sweeptype

FFT

AUTO

Preamp

off

off

Stablemode

Trace

Trace

Stablevalue

0.50 dB

0.50 dB

Report No: 76874RRF.001A2

Page 48 of 70

2025-01-30

DEKRA Testing and Certification, S.A.U. Parque Tecnológico de Andalucía, c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España C.I.F. A29507456
RSS-247 5.5 / FCC 15.247 (d) [RSE] Emission limitations radiated (Transmitter)

Limits
Radiated emissions which fall in the restricted bands, as defined in Section 15.205(a), must also comply with the radiated emission limits specified in Section 15.209(a) (see Section 15.205(c)/RSS-Gen):

Frequency Range (MHz)
0.009-0.490 0.490-1.705 1.705 - 30.0
30 - 88 88 - 216 216 - 960 Above 960

Field strength (µV/m)
2400/F(kHz) 24000/F(kHz)
30 100 150 200 500

Field strength (dBµV/m) 40 43.5 46 54

Measurement distance (m)
300 30 30 3 3 3 3

The emission limits shown in the above table are based on measurements employing CISPR quasi-peak detector except for the frequency bands 9-90 kHz, 110-490 kHz and above 1000 MHz. Radiated emission limits in these three bands are based on measurements employing an average detector.
For average radiated emission measurements above 1000 MHz, there is also a limit corresponding to 20 dB above the indicated values in the table is specified when measuring with peak detector function.
RSS-247: Attenuation below the general field strength limits specified in RSS-Gen is not required.

Frequency range tested for Radiated emissions: Start frequency: no radiofrequency signal generated in the device found below 10th sub-harmonic, no further investigation required. Stop frequency: it has been performed the radiated spurious emissions until 10th harmonic.
Modulation: BTLE 5.0 (GFSK 1 Mbit/s)
Results No spurious frequencies detected at less than 20 dB below the limit:
Verdict Pass

Report No: 76874RRF.001A2

Page 49 of 70

2025-01-30

DEKRA Testing and Certification, S.A.U. Parque Tecnológico de Andalucía, c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España C.I.F. A29507456

Attachments Frequency Range GHz = [0.03, 1] Modulation : This plot is valid for all channel and all modulations

Equipment Type = Digital Transmission System (DTS)

MIMO Mode = SISO Active Port = 1

Measurement Point = 1

Level in dBµV/m

This plot is valid for all channel and all modulations

Tables: Spectrum Analyzer Parameters

Subrange

Step Size Detectors Bandwidth Sweep Time Preamp

Receiver: [ESW 44]

30 MHz - 1 GHz 30,312 kHz PK+

100 kHz

1 s

0 dB

Report No: 76874RRF.001A2

Page 50 of 70

2025-01-30

DEKRA Testing and Certification, S.A.U. Parque Tecnológico de Andalucía, c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España C.I.F. A29507456

Frequency Range GHz = [1, 3]

Equipment Type = Digital Transmission System (DTS)

Modulation = BTLE 5.0 (GFSK 1 Mbit/s) Frequency MHz = 2402.00000

MIMO Mode = SISO

Measurement Point = 1

Active Port = 1

Images:

Report No: 76874RRF.001A2

Page 51 of 70

2025-01-30

DEKRA Testing and Certification, S.A.U. Parque Tecnológico de Andalucía, c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España C.I.F. A29507456

Tables: Spectrum Analyzer Parameters

Subrange

Step Size Detectors Bandwidth Sweep Time Preamp

Receiver: [ESW 44]

1 GHz - 3 GHz 30,769 kHz PK+ ; AVG 1 MHz

1 s

0 dB

Report No: 76874RRF.001A2

Page 52 of 70

2025-01-30

DEKRA Testing and Certification, S.A.U. Parque Tecnológico de Andalucía, c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España C.I.F. A29507456

Frequency Range GHz = [1, 3]

Equipment Type = Digital Transmission System (DTS)

Modulation = BTLE 5.0 (GFSK 1 Mbit/s) Frequency MHz = 2440.00000

MIMO Mode = SISO

Measurement Point = 1

Active Port = 1

Images:

Report No: 76874RRF.001A2

Page 53 of 70

2025-01-30

DEKRA Testing and Certification, S.A.U. Parque Tecnológico de Andalucía, c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España C.I.F. A29507456

Tables: Spectrum Analyzer Parameters

Subrange

Step Size Detectors Bandwidth Sweep Time Preamp

Receiver: [ESW 44]

1 GHz - 3 GHz 30,769 kHz PK+ ; AVG 1 MHz

1 s

0 dB

Report No: 76874RRF.001A2

Page 54 of 70

2025-01-30

DEKRA Testing and Certification, S.A.U. Parque Tecnológico de Andalucía, c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España C.I.F. A29507456

Frequency Range GHz = [1, 3]

Equipment Type = Digital Transmission System (DTS)

Modulation = BTLE 5.0 (GFSK 1 Mbit/s) Frequency MHz = 2480.00000

MIMO Mode = SISO

Measurement Point = 1

Active Port = 1

Images:

Report No: 76874RRF.001A2

Page 55 of 70

2025-01-30

DEKRA Testing and Certification, S.A.U. Parque Tecnológico de Andalucía, c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España C.I.F. A29507456

Tables: Spectrum Analyzer Parameters

Subrange

Step Size Detectors Bandwidth Sweep Time Preamp

Receiver: [ESW 44]

1 GHz - 3 GHz 30,769 kHz PK+ ; AVG 1 MHz

1 s

0 dB

Report No: 76874RRF.001A2

Page 56 of 70

2025-01-30

DEKRA Testing and Certification, S.A.U. Parque Tecnológico de Andalucía, c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España C.I.F. A29507456

Frequency Range GHz = [3, 17]

Equipment Type = Digital Transmission System (DTS)

Modulation = BTLE 5.0 (GFSK 1 Mbit/s) Frequency MHz = 2402.00000

MIMO Mode = SISO

Measurement Point = 1

Active Port = 1

Images:

Tables: Spectrum Analyzer Parameters

Subrange

Step Size Detectors Bandwidth Sweep Time Preamp

Receiver: [ESW 44]

3 GHz - 17 GHz 140 kHz PK+ ; AVG 1 MHz

1 s

30 dB

Report No: 76874RRF.001A2

Page 57 of 70

2025-01-30

DEKRA Testing and Certification, S.A.U. Parque Tecnológico de Andalucía, c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España C.I.F. A29507456

Frequency Range GHz = [3, 17]

Equipment Type = Digital Transmission System (DTS)

Modulation = BTLE 5.0 (GFSK 1 Mbit/s) Frequency MHz = 2440.00000

MIMO Mode = SISO

Measurement Point = 1

Active Port = 1

Images:

Tables: Spectrum Analyzer Parameters

Subrange

Step Size Detectors Bandwidth Sweep Time Preamp

Receiver: [ESW 44]

3 GHz - 17 GHz 140 kHz PK+ ; AVG 1 MHz

1 s

30 dB

Report No: 76874RRF.001A2

Page 58 of 70

2025-01-30

DEKRA Testing and Certification, S.A.U. Parque Tecnológico de Andalucía, c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España C.I.F. A29507456

Frequency Range GHz = [3, 17]

Equipment Type = Digital Transmission System (DTS)

Modulation = BTLE 5.0 (GFSK 1 Mbit/s) Frequency MHz = 2480.00000

MIMO Mode = SISO

Measurement Point = 1

Active Port = 1

Images:

Tables: Spectrum Analyzer Parameters

Subrange

Step Size Detectors Bandwidth Sweep Time Preamp

Receiver: [ESW 44]

3 GHz - 17 GHz 140 kHz PK+ ; AVG 1 MHz

1 s

30 dB

Report No: 76874RRF.001A2

Page 59 of 70

2025-01-30

DEKRA Testing and Certification, S.A.U. Parque Tecnológico de Andalucía, c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España C.I.F. A29507456
Frequency Range GHz = [17, 26]
Modulation = This plot is valid for all channel and all modulations MIMO Mode = SISO Active Port = 1
Images:

Equipment Type = Digital Transmission System (DTS)
Frequency MHz = This plot is valid for all channel
Measurement Point = 1

This plot is valid for all channel and all modulations
Tables: Spectrum Analyzer Parameters

Subrange

Step Size Detectors Bandwidth Sweep Time Preamp

Receiver: [FSV 40]

17 GHz - 26 GHz 300 kHz PK+ ; AVG 1 MHz

1 s

0 dB

Report No: 76874RRF.001A2

Page 60 of 70

2025-01-30

DEKRA Testing and Certification, S.A.U. Parque Tecnológico de Andalucía, c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España C.I.F. A29507456
Modulation: BTLE 5.0 (GFSK 2 Mbit/s)

Results Freq Rng (GHz)
[1, 3]

Equipment
Digital Transmission System (DTS)

Freq (MHz) Port 2480.00000 1

Unwanted Freq (MHz)
2483.662
2483.662

Unwanted Lvl (dBV/m)
61.44
51.26

Pol Detector

H

PK

H

AVG

Verdict Pass

Report No: 76874RRF.001A2

Page 61 of 70

2025-01-30

DEKRA Testing and Certification, S.A.U. Parque Tecnológico de Andalucía, c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España C.I.F. A29507456

Attachments

Frequency Range GHz = [1, 3]

Equipment Type = Digital Transmission System (DTS)

Modulation = BTLE 5.0 (GFSK 2 Mbit/s) Frequency MHz = 2402.00000

MIMO Mode = SISO

Measurement Point = 1

Active Port = 1

Images:

Report No: 76874RRF.001A2

Page 62 of 70

2025-01-30

DEKRA Testing and Certification, S.A.U. Parque Tecnológico de Andalucía, c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España C.I.F. A29507456

Tables: Spectrum Analyzer Parameters

Subrange

Step Size Detectors Bandwidth Sweep Time Preamp

Receiver: [ESW 44]

1 GHz - 3 GHz 30,769 kHz PK+ ; AVG 1 MHz

1 s

0 dB

Report No: 76874RRF.001A2

Page 63 of 70

2025-01-30

DEKRA Testing and Certification, S.A.U. Parque Tecnológico de Andalucía, c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España C.I.F. A29507456

Frequency Range GHz = [1, 3]

Equipment Type = Digital Transmission System (DTS)

Modulation = BTLE 5.0 (GFSK 2 Mbit/s) Frequency MHz = 2440.00000

MIMO Mode = SISO

Measurement Point = 1

Active Port = 1

Images:

Report No: 76874RRF.001A2

Page 64 of 70

2025-01-30

DEKRA Testing and Certification, S.A.U. Parque Tecnológico de Andalucía, c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España C.I.F. A29507456

Tables: Spectrum Analyzer Parameters

Subrange

Step Size Detectors Bandwidth Sweep Time Preamp

Receiver: [ESW 44]

1 GHz - 3 GHz 30,769 kHz PK+ ; AVG 1 MHz

1 s

0 dB

Report No: 76874RRF.001A2

Page 65 of 70

2025-01-30

DEKRA Testing and Certification, S.A.U. Parque Tecnológico de Andalucía, c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España C.I.F. A29507456

Frequency Range GHz = [1, 3]

Equipment Type = Digital Transmission System (DTS)

Modulation = BTLE 5.0 (GFSK 2 Mbit/s) Frequency MHz = 2480.00000

MIMO Mode = SISO

Measurement Point = 1

Active Port = 1

Images:

Report No: 76874RRF.001A2

Page 66 of 70

2025-01-30

DEKRA Testing and Certification, S.A.U. Parque Tecnológico de Andalucía, c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España C.I.F. A29507456

Tables: Spectrum Analyzer Parameters

Subrange

Step Size Detectors Bandwidth Sweep Time Preamp

Receiver: [ESW 44]

1 GHz - 3 GHz 30,769 kHz PK+ ; AVG 1 MHz

1 s

0 dB

Report No: 76874RRF.001A2

Page 67 of 70

2025-01-30

DEKRA Testing and Certification, S.A.U. Parque Tecnológico de Andalucía, c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España C.I.F. A29507456

Frequency Range GHz = [3, 17]

Equipment Type = Digital Transmission System (DTS)

Modulation = BTLE 5.0 (GFSK 2 Mbit/s) Frequency MHz = 2402.00000

MIMO Mode = SISO

Measurement Point = 1

Active Port = 1

Images:

Tables: Spectrum Analyzer Parameters

Subrange

Step Size Detectors Bandwidth Sweep Time Preamp

Receiver: [ESW 44]

3 GHz - 17 GHz 140 kHz PK+ ; AVG 1 MHz

1 s

30 dB

Report No: 76874RRF.001A2

Page 68 of 70

2025-01-30

DEKRA Testing and Certification, S.A.U. Parque Tecnológico de Andalucía, c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España C.I.F. A29507456

Frequency Range GHz = [3, 17]

Equipment Type = Digital Transmission System (DTS)

Modulation = BTLE 5.0 (GFSK 2 Mbit/s) Frequency MHz = 2440.00000

MIMO Mode = SISO

Measurement Point = 1

Active Port = 1

Images:

Tables: Spectrum Analyzer Parameters

Subrange

Step Size Detectors Bandwidth Sweep Time Preamp

Receiver: [ESW 44]

3 GHz - 17 GHz 140 kHz PK+ ; AVG 1 MHz

1 s

30 dB

Report No: 76874RRF.001A2

Page 69 of 70

2025-01-30

DEKRA Testing and Certification, S.A.U. Parque Tecnológico de Andalucía, c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España C.I.F. A29507456

Frequency Range GHz = [3, 17]

Equipment Type = Digital Transmission System (DTS)

Modulation = BTLE 5.0 (GFSK 2 Mbit/s) Frequency MHz = 2480.00000

MIMO Mode = SISO

Measurement Point = 1

Active Port = 1

Images:

Tables: Spectrum Analyzer Parameters

Subrange

Step Size Detectors Bandwidth Sweep Time Preamp

Receiver: [ESW 44]

3 GHz - 17 GHz 140 kHz PK+ ; AVG 1 MHz

1 s

30 dB

Report No: 76874RRF.001A2

Page 70 of 70

2025-01-30

