Hank Yan

LCSA12164352E FCC 47 CFR Part 15, Subpart B

ARTIKA FOR LIVING INC 12ST-DS Dark Sky Step Light Pro- Black 12in 2AUHG-12ST-DS 2AUHG12STDS 12st ds

PDF Viewing Options

Not Your Device? Search For Manuals or Datasheets below:


File Info : application/pdf, 16 Pages, 901.83KB

Document DEVICE REPORTGetApplicationAttachment.html?id=8198914
FCC ID: 2AUHG-12ST-DS

Page 1 of 16

Report No.:LCSA12164352E

FCC TEST REPORT For
ARTIKA FOR LIVING INC Dark Sky Step Light Pro- Black 12in
Test Model: 12ST-DS-MB10TE10 Additional Model No.:12ST-DS-XXXXXXXXXX("XXXXXXXXXX" can be A to Z
and/or 0 to 9 and/or blank (commercial code))

Prepared for Address

: ARTIKA FOR LIVING INC : 1756 50th avenue, Lachine, Qc, Canada H8T 2V5

Prepared by
Address
Tel Fax Web Mail

: Shenzhen LCS Compliance Testing Laboratory Ltd. 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park
: Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China
: +(86) 0755-82591330 : +(86) 0755-82591332 : www.lcs-cert.com : [email protected]

Date of receipt of test sample Number of tested samples Serial number Sample No. Date of Test Date of Report

: January 06, 2025 :1 : Prototype : B241225035001 : January 06, 2025 to January 09, 2025 : January 10, 2025

Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity

FCC ID: 2AUHG-12ST-DS

Page 2 of 16

Report No.:LCSA12164352E

TEST REPORT
Report No. ........................................... : LCSA12164352E Date of Issue........................................ : January 10, 2025
Testing Laboratory Name................. : Shenzhen LCS Compliance Testing Laboratory Ltd. Address................................................. : 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park
Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China
Testing Location/ Procedure.............. : Full application of Harmonised standards  Partial application of Harmonised standards  Other standard testing method 
Applicant's Name.............................. : ARTIKA FOR LIVING INC Address................................................. : 1756 50th avenue, Lachine, Qc, Canada H8T 2V5
Test Specification Standard............................................... : FCC 47 CFR Part 15, Subpart B
ANSI C63.4-2014
Test Report Form No.......................... : TRF-4-E-010 A/0 TRF Originator..................................... : Shenzhen LCS Compliance Testing Laboratory Ltd.
Master TRF.......................................... : Dated 2011-03
Shenzhen LCS Compliance Testing Laboratory Ltd. All rights reserved. This publication may be reproduced in whole or in part for non-commercial purposes as long as the Shenzhen LCS Compliance Testing Laboratory Ltd. is acknowledged as copyright owner and source of the material. Shenzhen LCS Compliance Testing Laboratory Ltd. takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context.
Test Item Description....................... : Dark Sky Step Light Pro- Black 12in Trade Mark........................................... : ARTIKA Test Model............................................ : 12ST-DS-MB10TE10
Result................................................... : Positive

Compiled by:

Supervised by:

Approved by:

Emma wang / File Administrator

Cary Luo/ Technique principal

Gavin Liang / Manager

Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity

FCC ID: 2AUHG-12ST-DS

Page 3 of 16

Report No.:LCSA12164352E

TEST REPORT
Test Report No.: LCSA12164352E

January 10, 2025 Date of issue

Test Model................................ : 12ST-DS-MB10TE10 EUT............................................. : Dark Sky Step Light Pro- Black 12in Applicant.................................... : ARTIKA FOR LIVING INC Address...................................... : 1756 50th avenue, Lachine, Qc, Canada H8T 2V5 Telephone.................................. : / Fax.............................................. : /
Manufacturer............................. : DONGGUAN CITY RISING STARS LIGHTING CO.,LTD Address...................................... : YUANQUAN ROAD, NO.6, BAIHAO VILLAGE, HOUJIE
TOWN Telephone.................................. : / Fax.............................................. : / Factory ........................................: DONGGUAN CITY RISING STARS LIGHTING CO.,LTD Address...................................... : YUANQUAN ROAD, NO.6, BAIHAO VILLAGE, HOUJIE
TOWN Telephone.................................. : / Fax.............................................. : /

Test Result

Positive

The test report merely corresponds to the test sample. It is not permitted to copy extracts of these test result without the written permission of the test laboratory.

Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity

FCC ID: 2AUHG-12ST-DS

Page 4 of 16

Report No.:LCSA12164352E

Revision History

Report Version 000

Issue Date January 10, 2025

Revision Content Initial Issue

Revised By /

Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity

FCC ID: 2AUHG-12ST-DS

Page 5 of 16

Report No.:LCSA12164352E

Test Report Description

TABLE OF CONTENTS

Page

1. SUMMARY OF STANDARDS AND RESULTS ................................................................................................. 6
1.1 Description of Standards and Results ........................................................................................................ 6 1.2 Description of Test Modes ...........................................................................................................................7
2. GENERAL INFORMATION ................................................................................................................................ 8
2.1 Description of Device (EUT) ....................................................................................................................... 8 2.2 Support equipment List ............................................................................................................................... 8 2.3 Description of Test Facility .......................................................................................................................... 8 2.4 Measurement Uncertainty ...........................................................................................................................8

3. MEASURING DEVICES AND TEST EQUIPMENT ........................................................................................... 9 4. EMISSION TEST RESULTS (EMI) .................................................................................................................. 10
4.1 Conducted emissions on AC mains .......................................................................................................... 10 4.2 Radiated emissions (Below 1GHz) ........................................................................................................... 13

5. TEST SETUP PHOTOS ................................................................................................................................... 16 6. EUT CONSTRUCTIONAL DETAILS (EUT PHOTOS) .................................................................................... 16

Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity

FCC ID: 2AUHG-12ST-DS

Page 6 of 16

Report No.:LCSA12164352E

1. SUMMARY OF STANDARDS AND RESULTS

1.1 Description of Standards and Results

The EUT have been tested according to the applicable standards as referenced below.

Description of Test Item

Standard

Limits

Conducted emissions on AC mains

FCC 47 CFR Part 15, Subpart B ANSI C63.4-2014

15.107, Class B

Radiated emissions (Below 1GHz)

FCC 47 CFR Part 15, Subpart B ANSI C63.4-2014

15.109, Class B

Result Pass Pass

Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity

FCC ID: 2AUHG-12ST-DS

Page 7 of 16

1.2 Description of Test Modes

No Title

Description

TM1 Working(AC 120V/60Hz) Record

Report No.:LCSA12164352E

Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity

FCC ID: 2AUHG-12ST-DS

Page 8 of 16

Report No.:LCSA12164352E

2. GENERAL INFORMATION

2.1 Description of Device (EUT)

EUT

: Dark Sky Step Light Pro- Black 12in

Test Model

: 12ST-DS-MB10TE10

Additional Model No.

:

12ST-DS-XXXXXXXXXX("XXXXXXXXXX" can be A to Z and/or 0 to 9 and/or blank (commercial code))

Model Declaration

:

PCB board, structure and internal of these model(s) are the same, So no additional models were tested.

Power Supply

: 120V~ 60Hz 20W

Highest Internal Frequency

: 1.705-108MHz

Classification of Equipment

: Class B

Highest internal frequency (Fx)

Highest measured frequency

Fx  1.705MHz 1.705MHz < Fx  108MHz 108MHz < Fx  500MHz 500MHz < Fx  1000MHz
Fx > 1GHz

30MHz 1GHz 2GHz 5GHz 5 x Fx up to a maximum of 40GHz

2.2 Support equipment List
The EUT was tested as an independent device.
2.3 Description of Test Facility
The data and results referenced in this document are true and accurate. The reader is cautioned that there may be errors within the calibration limits of the equipment and facilities. The measurement uncertainty was calculated for all measurements listed in this test report acc. To CISPR 16 ­ 4 "Specification for radio disturbance and immunity measuring apparatus and methods ­ Part 4: Uncertainty in EMC Measurements" and is documented in the LCS quality system acc. To DIN EN ISO/IEC 17025. Furthermore, component and process variability of devices similar to that tested may result in additional deviation. The manufacturer has the sole responsibility of continued compliance of the device.

NVLAP Accreditation Code is 600167-0. FCC Designation Number is CN5024. CAB identifier is CN0071. CNAS Registration Number is L4595. Test Firm Registration Number: 254912.
2.4 Measurement Uncertainty

Test Item

Measurement Uncertainty

Conducted Emission (150kHz to 30MHz)

± 2.35 dB

Radiated Emission (30MHz to 1000MHz)

± 3.48 dB

Note: This uncertainty represents an expanded uncertainty expressed at approximately the 95% confidence level using a coverage factor of k=2.

Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity

FCC ID: 2AUHG-12ST-DS

Page 9 of 16

Report No.:LCSA12164352E

3. MEASURING DEVICES AND TEST EQUIPMENT

Conducted emissions on AC mains

Equipment

Manufacturer Model No

EMI Test Software

Farad

EZ

Artificial Mains

R&S

ENV216

Pulse Limiter

R&S

ESH3-Z2

EMI Test Receiver

R&S

ESR3

Serial No.
/ 101288 102750-NB 102312

Cal Date
/ 2024-06-06 2024-06-06 2024-03-12

Due Date
/ 2025-06-05 2025-06-05 2025-03-11

Radiated emissions (Below 1GHz) (Above 1GHz)

Equipment

Manufacturer Model No Serial No.

EMI Test Software

AUDIX

E3

/

By-log Antenna

SCHWARZBECK VULB9163

01143

Horn Antenna

SCHWARZBECK

3115

EABF-018

EMI Test Receiver

R&S

ESR3

102311

Broadband Preamplifier

/

BP-01M18G

P190501

EMI Test Receiver

R&S

ESCI7

101173

By-log Antenna

SchwarzZBECK VULB9163

01565

EMI Test Software

Farad

EZ

/

Cal Date
N/A 2024-07-20 2024-07-20 2024-06-06
2024-06-06
2024-10-06 2024-07-13
N/A

Due Date
N/A 2027-07-19 2027-07-19 2025-06-05
2025-06-05
2025-10-07 2027-07-12
N/A

Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity

FCC ID: 2AUHG-12ST-DS

Page 10 of 16

Report No.:LCSA12164352E

4. EMISSION TEST RESULTS (EMI)

4.1 Conducted emissions on AC mains

Test Requirement: Test Limit:

15.107, Class B

Frequency of emission (MHz) Conducted limit (dBV)

Quasi-peak

Average

0.15-0.5

66 to 56*

56 to 46*

0.5-5

56

46

5-30

60

50

*Decreases with the logarithm of the frequency.

Test Method: Procedure:

ANSI C63.4-2014
An initial pre-scan was performed with peak detector.Quasi-Peak or Average measurement were performed at the frequencies with maximized peak emission were detected. Remark: Level= Read Level+ Cable Loss+ LISN Factor

4.1.1 E.U.T. Operation:

Operating Environment:

Temperature: 24.4 °C

Pre test mode:

TM1

Final test mode:

TM1

Humidity: 53.0 %

4.1.2 Test Setup Diagram:

Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity

FCC ID: 2AUHG-12ST-DS
4.1.3 Test Data:
TM1 / Line: Line

Page 11 of 16

Report No.:LCSA12164352E

Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity

FCC ID: 2AUHG-12ST-DS TM1 / Line: Neutral

Page 12 of 16

Report No.:LCSA12164352E

***Note: 1) Pre-scan all modes and recorded the worst case results in this report. 2) Margin= Reading level + Correct factor­Limit Correct Factor=Lisn Factor+Cable Factor+Insertion loss of Pulse Limitter
Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity

FCC ID: 2AUHG-12ST-DS

Page 13 of 16

Report No.:LCSA12164352E

4.2 Radiated emissions (Below 1GHz)

Test Requirement:

15.109, Class B

Test Limit:

Except for Class A digital devices, the field strength of radiated emissions from unintentional radiators at a distance of 3 meters shall not exceed the following values:

Frequency of emission (MHz)

Field strength @3m

Field strength @10m

(uV/m)

(dBuV/ (uV/m) (dBuV/m) m)

30 ­ 88

100

40

30

29.5

88 ­ 216

150

43.5 45

33.1

216 ­ 960

200

46

60

35.6

Above 960

500

54

150

43.5

Test Method:

ANSI C63.4-2014

Procedure:

An initial pre-scan was performed in the chamber using the spectrum analyser in peak detection mode. Quasi-peak measurements were conducted based on the peak sweep graph. The EUT was measured by BiConiLog antenna with 2 orthogonal polarities.
Remark: Level= Read Level+ Cable Loss+ Antenna Factor- Preamp Factor

4.2.1 E.U.T. Operation:

Operating Environment:

Temperature: 26.4 °C

Humidity: 54.2 %

Pre test mode:

TM1

Final test mode:

TM1

4.2.2 Test Setup Diagram:

Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity

FCC ID: 2AUHG-12ST-DS
4.2.3 Test Data:
TM1 / Polarization: Horizontal

Page 14 of 16

Report No.:LCSA12164352E

Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity

FCC ID: 2AUHG-12ST-DS TM1 / Polarization: Vertical

Page 15 of 16

Report No.:LCSA12164352E

Note:1).Pre-Scan all mode, Thus record worse case mode result in this report. 2) Margin= Reading level + Correct factor ­ Limit Correct Factor=Antenna Factor+Cable Factor- Pre-amplifier Factor
Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity

FCC ID: 2AUHG-12ST-DS

Page 16 of 16

Report No.:LCSA12164352E

5. TEST SETUP PHOTOS
Refer to Appendix - Test Setup Photos for LCSA12164352E.docx
6. EUT CONSTRUCTIONAL DETAILS (EUT PHOTOS)
Refer to Appendix - EUT Photos for LCSA12164352E.docx
--- End of Report ---

Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity



Related FCC IDs:

Search Any Device: