H4A6S 16 SEER2 Single-Stage Air Conditioner with R-410A Refrigerant 1-1/2 To 5 Tons

Product Specifications

This unit has been designed utilizing R-410A refrigerant. The environmentally sound refrigerant allows you to make a responsible decision in the protection of the earth's ozone layer.
NOTE: Ratings contained in this document are subject to change at any time. Always refer to the AHRI directory (www.ahridirectory.org) for the most up-to-date ratings information.

Features / Benefits Efficiency
· 13.8 - 16.0 SEER2 (14 - 16.5 SEER) / 11.2 ­ 13.0 EER2 (11.2 - 13.0 EER)
· Indoor air quality accessories available
Reliability
· R-410A refrigerant - environmentally sound, won't deplete the ozone layer and low lifetime service cost.
· Scroll compressor · Internal pressure relief valve · Internal thermal overload · Filter drier
Durability
· Protection Package: Solid, Durable sheet metal construction
Applications
· Long­line ­ up to 250 feet (76.20 m) total equivalent length, up to 200 feet (60.96 m) condenser above evaporator, or up to 80 ft. (24.4 m) evaporator above condenser (See Long Line Guide for more information.)
· Low ambient cooling (down to 0°F / -18°C ) with approved low ambient accessory kits.

STANDARD FEATURES
Features R-410A Refrigerant SEER2 (Range depending on indoor combination) Scroll Compressor Field Installed Filter Drier Front Seating Service Valves Internal Pressure Relief Valve Internal Thermal Overload Long Line Capability Low Ambient Capability with Kit High Pressure Switch Low Pressure Switch Compressor Sound Blanket

18

24

30

36

42

48

X

X

X

X

X

X

14.3 - 16 14.3 - 16 14.3 - 16 14.3 - 16 13.8 - 15 13.8 - 15

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

49 X 14 - 16 X X X X X X X X X X

60 X 13.8 - 15 X X X X X X X X X X

61 X 14 - 16 X X X X X X X X X X

H4A6S: Product Specifications

MODEL NUMBER NOMENCLATURE

C

4

A

6

S

18

A

K

A

W

Brand H = Mainline
Hei

Refrigerant 4 = R-410A

Type A = AC

SEER2 OD Design Type Nominal

6= 16 SEER2 S= Single Stage

Capacity

18 = 1.5 Tons

24 = 2 Tons

30 = 2.5 Tons

36 = 3 Tons

42 = 3.5 Tons

48 = 4 Tons

49 = 4 Tons

60 = 5 Tons

61 = 5 Tons

Feature

Voltage

Special

Region

A = Standard K = 208/230-60-1 Feature W = Standard

A = Standard Southwest AC

A
Major Series A = Initial

CATALOG ORDERING NUMBERS
Size 18 24 30 36 42 48 49 60 61

Model Number H4A6S18AKAWA H4A6S24AKAWA H4A6S30AKAWA H4A6S36AKAWA H4A6S42AKAWA H4A6S48AKAWA H4A6S49AKAWA H4A6S60AKAWA H4A6S61AKAWA

®

Physical Data

Unit Size

18

Compressor Type

REFRIGERANT

Control

Factory Charge lb (kg)* 5.30 (2.40)

COND FAN

Air Discharge

Air Qty (CFM)

2400

Motor HP

1/12

Motor RPM

1100

COND COIL

Face Area (Sq ft)

17.2

Fins per In.

25

Rows

1

Circuits

4

VALVE CONNECT. (In. ID)

Vapor

3/4

Liquid

REFRIGERANT TUBES* (In. OD)

Rated Vapor

3/4

Rated Liquid Line

24
6.10 (2.77)
2400 1/12 1100

30
6.60 (2.99)
2575 1/10 1100

36

42

48

Scroll

R-410A

TXV (R-410A Hard Shutoff)

6.80 (3.08) 8.10 (3.67) 8.10 (3.67)

Propeller Type, Direct Drive

Vertical

3700

3890

3890

1/4

1/4

1/4

1100

1100

1100

49
12.40 (5.62)
4090 1/3 800

17.2

19.4

21.5

17.2

17.2

30.1

25

25

25

20

20

20

1

1

1

2

2

2

4

5

6

8

8

10

3/4

3/4

7/8

7/8

7/8

7/8

3/8"

3/4

3/4

7/8

7/8

7/8

7/8

3/8"

60
10.10 (4.58)
4260 1/4
1100 21.5 20
2 9 7/8
1 1/8

61
14.50 (6.58)
4320 1/3 800 30.1 20 2 12 7/8
1 1/8

*. For 15 ft. Line Set .Units are rated with 25 ft. (7.6m) of lineset length. See Vapor Line Sizing and Cooling Capacity Loss table when using other sizes and lengths of lineset. .See Liquid Line Sizing For Cooling Only Systems with R-410A Refrigerant tables

Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 2

H4A6S: Product Specifications

REFRIGERANT PIPING LENGTH LIMITATIONS Liquid Line Sizing and Maximum Total Equivalent Lengths for Cooling Only Systems with R-410A Refrigerant:
The maximum allowable length of a residential split system depends on the liquid line diameter and vertical separation between indoor and outdoor units.
See Table below for liquid line sizing and maximum lengths :

Size
18000
24000
30000 36000 42000 48000 60000

Liquid Line Connection

Liquid Line Diam.
w/ TXV

1/4

3/8

5/16

3/8

1/4

3/8

5/16

3/8

1/4

3/8

5/16

3/8

3/8

5/16 3//8

3/8

5/16 3/8

3/8

3/8

3/8

3/8

0-5 (0-1.5)
150 250* 250* 75 250* 250* 30 175 250* 175 250* 125 250* 250* 250*

Table 1 ­ Maximum Total Equivalent Length*

Outdoor Unit BELOW Indoor Unit

AC with R-410A Refrigerant Maximum Total Equivalent Length: Outdoor unit BELOW Indoor Vertical Separation ft (m)

6-10 (1.8-3.0)

11-20 (3.4-6.1)

21-30 (6.4-9.1)

31-40

41-50

51-60

61-70

(9.4-12.2) (12.5-15.2) (15.5-18.3) (18.6-21.3)

150

125

100

100

75

--

--

250*

250*

250*

250*

250*

250*

225*

250*

250*

250*

250*

250*

250*

250*

75

75

50

50

--

--

--

250*

250*

250*

250*

225*

175

125

250*

250*

250*

250*

250*

250*

250*

--

--

--

--

--

--

--

225*

200

175

125

100

75

--

250*

250*

250*

250*

250*

250*

250*

150

150

100

100

100

75

--

250*

250*

250*

250*

250*

250*

250*

100

100

75

75

50

--

--

250*

250*

250*

250*

250*

250*

250*

250*

250*

250*

250*

250*

230

160

250*

250*

225*

190

150

110

--

71-80 (21.6-24.4)
-150 250*
-100 250*
--250* -250* -150 ---

*.Maximum actual length not to exceed 200 ft (61 m) .Total equivalent length accounts for losses due to elbows or fitting. See the Long Line Guideline for details. -- = outside acceptable range

Table 2 ­ Maximum* Total Equivalent Length

Outdoor Unit ABOVE Indoor Unit

Size

Liquid Line Connection

Liquid Line Diam. w/ TXV
1/4

25 (7.6)
175

AC with R-410A Refrigerant Maximum Total Equivalent Length: Outdoor unit ABOVE Indoor Vertical Separation ft (m)

26-50 (7.9-15.2)

51-75 (15.5-22.9)

76-100 (23.2-30.5)

101-125 (30.8-38.1)

126-150 (38.4-45.7)

151-175 (46.0-53.3)

176-200 (53.6-61.0)

250*

250*

250*

250*

250*

250*

250*

18000

3/8

5/16

250*

250*

250*

250*

250*

250*

250*

250*

3/8

250*

250*

250*

250*

250*

250*

250*

250*

1/4

100

125

175

200

225*

250*

250*

250*

24000

3/8

5/16

250*

250*

250*

250*

250*

250*

250*

250*

3/8

250*

250*

250*

250*

250*

250*

250*

250*

1/4

30

--

--

--

--

--

--

--

30000

3/8

5/16

250*

250*

250*

250*

250*

250*

250*

250*

3/8

250*

250*

250*

250*

250*

250*

250*

250*

36000

3/8

5/16

225*

250*

250*

250*

250*

250*

250*

250*

3/8

250*

250*

250*

250*

250*

250*

250*

250*

42000

3/8

5/16

175

200

250*

250*

250*

250*

250*

250*

3/8

250*

250*

250*

250*

250*

250*

250*

250*

48000

3/8

60000

3/8

3/8

250*

250*

250*

250*

250*

250*

250*

250*

3/8

250*

250*

250*

250*

250*

250*

250*

250*

*.Maximum actual length not to exceed 200 ft (61 m) .Total equivalent length accounts for losses due to elbows or fitting. See the Long Line Guideline for details. -- = Outside acceptable range

Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 3

H4A6S: Product Specifications

Table 3 ­ Refrigerant Charge Adjustments

Liquid Line Size 3/8
5/16 1/4

R-410A Charge oz/ft (g/m) 0.60 (17.74)
(Factory charge for lineset = 9 oz / 266.16 g) 0.40 (11.83) 0.27 (7.98)

Units are factory charged for 15 ft (4.6 m) of 3/8" liquid line. The factory charge for 3/8" lineset 9 oz.(266.16 g). When using other length or diameter liquid lines, charge adjustments are required per the chart above.

Charging Formula:

[(Lineset oz/ft X total length) ­ (factory charge for lineset)] = charge adjustment

Example 1: System has 15 ft of lineset* using existing 1/4" liquid line. What charge adjustment is required?

Formula:(.27 oz/ft X 15ft) ­ (9 oz) = (4.95) oz.

Net result is to remove 4.95 oz of refrigerant from the system

Example 2: System has 45 ft of existing 5/16" liquid line. What is the charge adjustment?

Formula:(.40 oz/ft. X 45ft) ­ (9 oz.) = 9 oz.

Net result is to add 9 oz of refrigerant to the system

NOTE: Conditions must be favorable for charging by subcooling method. Indoor temperature must be 70°F to 80°F (21°C to 27°C), and outdoor temperature must be 70°F to 100°F (21°C to 38°C). If outside these conditions, adjust charge for long linesets by weigh-in method.

* When applicable. Refer to Physical Data Table in this PD and to the Installation Instructions for more information.

Long Line Applications

An application is considered Long Line, when the refrigerant level in the system requires the use of accessories to maintain acceptable refrigerant management for systems reliability. See Accessory Usage Guideline table for required accessories. Defining a system as long line depends on the liquid line diameter, actual length of the tubing, and vertical separation between the indoor and outdoor units.
For Air Conditioner systems, the chart below shows when an application is considered Long Line.

Table 4 ­ AC with R-410A Refrigerant Long Line Description ft (m) Beyond these lengths, a TXV is required

Total Length

Outdoor Unit Above or Below Indoor Unit

TXV required beyond 50 ft. (15.2 m)

TXV required beyond 20 ft. (6.1 m)

Table 5 ­ AC with R-410A Refrigerant Long Line Description ft (m) (Beyond these lengths, long line accessories are required)

Liquid Line Size

Units On Same Level

Outdoor Below Indoor

Outdoor Above Indoor

1/4 + TXV

No accessories needed within allowed lengths

No accessories needed within allowed lengths

175 (53.3)

5/16 + TXV

120 (36.6)

50 (15.2) vertical or 120 (36.6) total

120 (36.6)

3/8 + TXV

80 (24.4)

35 (10.7) vertical or 80 (24.4) total

80 (24.4)

Note: See Residential Piping and Long Line Guideline for details

Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 4

H4A6S: Product Specifications

VAPOR LINE SIZING AND COOLING CAPACITY LOSS

Acceptable vapor line diameters provide adequate oil return to the compressor while avoiding excessive capacity loss. The suction line diameters shown in the chart below are acceptable for AC systems with R-410A refrigerant:

Table 6 ­ Vapor Line Sizing and Cooling Capacity Losses -- R-410A Refrigerant 1-Stage Air Conditioner Applications

Unit Nominal Size (Btuh)

Maximum Liquid Line Diameters
(In. OD)

18

3/8

24

3/8

30

3/8

36

3/8

42

3/8

48, 49

3/8

60, 61

3/8

Vapor Line Diameters
(In. OD)
1/2 5/8 3/4 5/8 3/4 7/8 5/8 3/4 7/8 5/8 3/4 7/8 3/4 7/8 1 1/8 3/4 7/8 1 1/8 3/4 7/8 1 1/8

26-50 (7.9-15.2)
1 0 0 0 0 0 1 0 0 1 0 0 0 0 0 0 0 0 1 0 0

Cooling Capacity Loss (%) Total Equivalent Line Length ft. (m)
1-Stage AC with R-410A

51-80

81-100 101-125 126-150 151-175 176-200 201-225 226-250

(15.5-24.4) (24.7-30.5) (30.8-38.1) (38.4-45.7) (46.0-53.3) (53.6-61.0) (61.3-68.6) (68.9-76.2)

2

3

5

6

7

8

9

11

1

1

1

2

2

2

3

3

0

0

0

1

1

1

1

1

1

2

2

3

3

4

5

5

0

1

1

1

1

1

2

2

0

0

0

0

1

1

1

1

2

3

3

4

5

6

7

8

0

1

1

1

2

2

2

3

0

0

0

1

1

1

1

1

2

4

5

6

8

9

10

12

1

1

2

2

3

3

4

4

0

0

1

1

1

1

2

2

1

2

2

3

4

4

5

6

0

1

1

1

2

2

2

3

0

0

0

0

0

0

0

0

1

2

3

4

5

5

6

7

0

1

1

2

2

2

3

3

0

0

0

0

0

0

1

1

2

4

5

6

7

9

10

11

1

2

2

3

4

4

5

5

0

0

1

1

1

1

1

1

Applications in this area may be long line and may have height restrictions. See the Residential Piping and Long Line Guideline.

Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 5

H4A6S: Product Specifications

ACCESSORIES

KIT NUMBER

KIT NAME

18

24

30

36

42

48

49

60

61

NASA00201FS

FRZ THERM KIT

X

X

X

X

X

X

X

X

X

NASA001TD

TIME DELAY KIT (90 second TDR)

X

X

X

X

X

X

X

X

X

NASA00201TD

TIME DELAY KIT (30 second TDR)

X

X

X

X

X

X

X

X

X

NASA401LA

LOW AMBIENT COOLING KIT

X

X

X

X

X

X

X

X

X

NASA00301PM

FAN MOTOR KIT*

X

X

NASA012SC

HARD START KIT

X

X

X

X

X

X

X

X

X

NASA001AC

CYCLE PROTR KIT

X

X

X

X

X

X

X

X

X

NASA00201SF

SPRT FEET KIT

X

X

X

X

X

X

X

X

X

NASA401LS

SOL VALVE KIT

X

X

X

X

X

X

X

X

X

NASA00201WS WINTER ST KIT

X

X

X

X

X

X

X

X

X

NASA00601CH CRKC HTR KIT

X

X

X

X

NASA00501CH CRKC HTR KIT

X

X

X

NAEA40501TX

TXV KIT (For use with copper coils)

X

X

X

NAEA40601TX

TXV KIT (For use with copper coils)

X

X

NAEA40701TX

TXV KIT (For use with copper coils)

X

X

X

X

NAEB40501TX

TXV KIT (For use with aluminum coils)

X

X

X

NAEB40601TX

TXV KIT (For use with aluminum coils)

X

X

NAEB40701TX

TXV KIT (For use with aluminum coils)

X

X

X

X

*.Required for use with low ambient kits. Rated efficiency will not be met with this accessory installed. X = Accessory

Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 6

H4A6S: Product Specifications

ACCESSORY USAGE GUIDELINE

ACCESSORY
Ball Bearing Fan Motor Compressor Start Assist Capacitor and Relay Crankcase Heater Evaporator Freeze Thermostat Hard Shut-Off TXV Liquid Line Solenoid Valve Low-ambient Pressure Switch Support Feet Winter Start Control

REQUIRED FOR LOW-AMBIENT COOLING
APPLICATIONS (Below 55_F/12.8_C)
Standard Yes Yes Yes Yes No Yes
Recommended Yes

REQUIRED FOR LONG LINE APPLICATIONS*
Standard Yes Yes No Yes
See Long Line Guideline No No No

REQUIRED FOR SEA COAST
APPLICATIONS (Within 2 miles/3.22 km)
Standard No No No Yes No
No
Recommended
No

*.For tubing set lengths between 80 and 200 ft. (24 and 61 m) horizontal or 35 ft. (10.7 m) vertical differential (total equivalent length), refer to the Residential Split-System Long Line Application Guideline.
.In units equipped with ECM OD motor, motor and fan needs to be replaced per unit accessory guide to work properly. Unit will not meet AHRI rated efficiency once motor and fan are replaced to use this accessory.
.Required if Low Pressure Switch is factory or field installed.

Accessory Description and Usage (Listed Alphabetically)

1. Ball-Bearing Fan Motor

6. Low-Ambient Pressure Switch Kit

A fan motor with ball bearings which permits speed reduction while maintaining bearing lubrication.
2. Compressor Start Assist - Capacitor and Relay Start capacitor and relay gives a "hard" boost to compressor motor at each start up. Usage Guideline: Required for single-phase scroll compressors in the following
applications: Long line Low ambient cooling
Suggested for all compressors in areas with a history of low voltage problems.

A long life pressure switch which is mounted to outdoor unit service valve. It is designed to cycle the outdoor fan motor in order to maintain head pressure within normal operating limits (approximately 100 psig to 225 psig). The control will maintain working head pressure at low-ambient temperatures down to 0_F (-18_C) when properly installed and also using wind baffles. Instructions provided in accessory kit.
Usage Guideline:
A Low-Ambient Pressure Switch must be used when cooling operation is used at outdoor temperatures below 55_F (12.8_C).
7. Outdoor Air Temperature Sensor
This device enables the thermostat to display the outdoor temperature. This device is also required to enable special thermostat features such as auxiliary heat lock out.

3. Crankcase Heater

Usage Guideline:

An electric resistance heater which mounts to the base of the compressor to keep the lubricant warm during off cycles. Improves compressor lubrication on restart and minimizes the chance of liquid slugging. Usage Guideline:
Required in low ambient cooling applications. Required in long line applications. Suggested in all commercial applications.

Suggested for use with compatible thermostats.
8. Sound Hood Wraparound sound reducing cover for the compressor. Reduces the sound level of the compressor. Usage Guideline:
Suggested when unit is installed closer than 15 ft (4.57 m) to quiet areas, bedrooms, etc.

4. Cycle Protector

Suggested when unit is installed between two houses less than

The cycle protector is designed to prevent compressor short cycling.

10 ft (3 m) apart.

This control provides an approximate 5-minute delay after power to the

compressor has been interrupted for any reason, including power outage,

protector control trip, thermostat jiggling, or normal cycling.

5. Evaporator Freeze Thermostat

An SPST temperature-actuated switch that stops unit operation when evaporator reaches freeze-up conditions.

Usage Guideline:

Required when low ambient kit has been added.

Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 7

H4A6S: Product Specifications
Accessory Description and Usage (Listed Alphabetically) Continued

9. Support Feet
Four or five stick-on plastic feet that raise the unit 4 in. (101.6 mm) above the mounting pad. This allows sand, dirt, and other debris to be flushed from the unit base, minimizing corrosion. Usage Guideline:
Suggested in the following applications: Coastal installations. Windy areas or where debris is normally circulating. Rooftop installations. For improved sound ratings.
10. Thermostatic Expansion Valve (TXV) A modulating flow-control valve which meters refrigerant liquid flow rate into the evaporator in response to the superheat of the refrigerant gas leaving the evaporator. Kit includes valve, adapter tubes, and external equalizer tube. Hard shut off types are available. Usage Guideline:
Required to achieve AHRI ratings in certain equipment combinations. Refer to combination ratings. Hard shut off TXV or LLS required in air conditioner long line applications. Required for use on all zoning systems.

11. Time-Delay Relay
An SPST delay relay which briefly continues operation of indoor blower motor to provide additional cooling after the compressor cycles off.
NOTE: Most indoor unit controls include this feature. For those that do not, use the guideline below.
Usage Guideline:
For improved efficiency ratings for certain combinations of indoor and outdoor units. Refer to AHRI Directory of Certified Product Performance (AHRI Directory).
When a Time-Delay Relay (TDR) is called for in the AHRI Directory, use a 30 second TDR for MicroChannel Indoor units and use a 90 second TDR for Round Tube Plate Fin Indoor units.
12. Winter Start Control
This control is designed to alleviate nuisance opening of the low-pressure switch by bypassing it for the first 3 minutes of operation.

Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 8

H4A6S: Product Specifications
AHRI RATINGS
For AHRI ratings certificates, please refer to the AHRI directory www.ahridirectory.org Additional ratings and system combinations can be accessed via the Ratings Database here: Heil Ratings

Electrical Data
UNIT SIZE
18 24 30 36 42 48 49 60 61

V/PH 208/230/1

OPER VOLTS*

MAX

MIN

253

197

COMPR

LRA

RLA

42.6

8.8

49.7

9.3

71.3

11.7

80.1

12.2

120.0

25.0

120.0

25.0

124.0

18.5

150.0

25.6

140.6

26.3

FAN FLA 0.50 0.50 0.60 1.40 1.52 1.52 2.80 1.40 2.80

*.Permissible limits of the voltage range at which the unit will operate satisfactorily .Time-Delay fuse.
FLA- Full Load Amps LRA - Locked Rotor Amps MCA- Minimum Circuit Amps RLA- Rated Load Amps NOTE:Control circuit is 24V on all units and requires external power source. Copper wire must be used from service disconnect to unit.
All motors/compressors contain internal overload protection. Complies with requirements of ASHRAE Standards 90.1 Short Circuit Current Rating (SCCR): 5kA rms

MCA
11.5 12.1 15.2 16.7 32.8 32.8 25.9 33.4 35.7

MAX FUSE or CKT BRK AMPS 20 20 25 25 50 50 40 50 50

A-Weighted Sound Power (dBA)

UNIT SIZE
18 24 30 36 42 48 49 60 61

STANDARD RATING 74 73 71 74 73 73 72 72 72

125 67.1 69.9 62.9 68.8 73.8 73.8 63.9 71.6 67.5

TYPICAL OCTAVE BAND SPECTRUM (without tone adjustment)

250

500

1000

2000

4000

66.8

69.3

68.2

64.3

59.9

66.6

69.9

70.5

61.8

58.2

64.5

66.7

69.1

61.3

57.4

69.2

70.1

67.3

64.0

60.5

72.9

70.9

69.4

62.9

60.1

72.9

70.9

69.4

62.9

60.1

67.0

71.5

66.2

59.8

56.8

71.6

70.2

67.8

62.4

59.2

68.6

68.0

68.7

59.4

55.8

NOTE: Tested in compliance with AHRI 270 but not listed with AHRI.

8000 53.1 51.6 52.3 56.0 54.8 54.8 52.9 58.4 52.0

Charging Subcooling (TXV-Type Expansion Device)

UNIT SIZE 18 24 30 36 42 48 49 60 61

REQUIRED SUBCOOLING (F) 8 8 10 8 10 10 8 14 9

Indoor TXV

Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 9

H4A6S: Product Specifications
Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 10

DIMENSIONS

H4A6S: Product Specifications
Wall
Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 11

CLEARANCES

Wall

Clearances (various examples)
Wall

6" (152.4 mm)

24" Service

24" (609.6) Service

12" (304.8)
12" (304.8)

12" (304.8)

6" (152.4)

12" (304.8)

24" (609.6) Service
18" (457.2)

Wall
24" (609.6) Service
18" (457.2)

24" (609.6) Service
18" (457.2)

Note: Numbers in ( ) = mm Allow 48" above unit
IMPORTANT: When installing multiple units in an alcove, roof well, or partially enclosed area, ensure there is adequate ventilation to prevent re-circulation of discharge air.

H4A6S: Product Specifications
Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 12

DETAILED COOLING CAPACITIES#

EVAPORATOR AIR

CFM

EWB

72 (22.2) 67 (19.4) 525 63 (17.2) 62 (16.7) 57 (13.9) 72 (22.2) 67 (19.4) 610 63 (17.2) 62 (16.7) 57 (13.9) 72 (22.2) 67 (19.4) 675 63 (17.2) 62 (16.7) 57 (13.9)

72 (22.2) 67 (19.4) 700 63 (17.2) 62 (16.7) 57 (13.9) 72 (22.2) 67 (19.4) 800 63 (17.2) 62 (16.7) 57 (13.9) 72 (22.2) 67 (19.4) 900 63 (17.2) 62 (16.7) 57 (13.9)

875 990 1125

72 (22.2) 67 (19.4) 63 (17.2) 62 (16.7) 57 (13.9) 72 (22.2) 67 (19.4) 63 (17.2) 62 (16.7) 57 (13.9) 72 (22.2) 67 (19.4) 63 (17.2) 62 (16.7) 57 (13.9)

75 (23.9) Capacity MBtuh
Total Sys. kW** Total Sens

21.27 19.22 17.81 17.44 17.14 21.80 19.72 18.26 17.96 17.79 22.13 20.02 18.52 18.26 18.31

10.54 12.74 12.28 14.86 17.14 11.01 13.50 12.97 15.99 17.79 11.35 14.02 13.46 16.81 18.31

1.11 1.12 1.13 1.13 1.14 1.15 1.16 1.17 1.17 1.17 1.17 1.19 1.20 1.20 1.20

28.29 25.78 23.85 23.50 22.77 28.70 26.31 24.47 24.02 23.37 29.02 26.75 24.74 24.41 24.17

13.93 16.87 16.26 19.78 22.77 14.52 17.71 17.05 20.98 23.37 14.94 18.46 17.79 22.05 24.17

1.50 1.52 1.53 1.53 1.54 1.54 1.56 1.57 1.57 1.58 1.58 1.60 1.62 1.62 1.62

34.76 31.61 29.29 28.84 27.77 35.51 32.26 29.98 29.46 28.86 35.99 32.82 30.52 29.97 29.84

16.74 20.37 19.65 23.81 27.77 17.32 21.30 20.55 25.16 28.86 17.93 22.27 21.46 26.60 29.84

1.98 1.97 1.96 1.96 1.96 2.04 2.03 2.02 2.02 2.02 2.10 2.09 2.08 2.08 2.08

CONDENSER ENTERING AIR TEMPERATURES °F (°C)

85 (29.4)

95 (35)

105 (40.6)

Capacity MBtuh Total Sens

Capacity MBtuh

Capacity MBtuh

Total Sys. kW**

Total Sys. kW**

Total Sys. kW**

Total Sens

Total Sens

H4A6S18*K*WAA* Outdoor Section With ESD4X24M14A* Indoor Section

20.26 10.21

1.24

19.26 9.83

1.39

18.26 9.39

1.55

18.38 12.42

1.25

17.49 12.04

1.40

16.60 11.61

1.56

16.96 11.91

1.26

16.06 11.45

1.40

15.25 11.07

1.57

16.66 14.55

1.26

15.86 14.15

1.40

14.90 13.68

1.56

16.21 16.21

1.26

15.57 15.57

1.40

14.88 14.88

1.57

20.72 10.62

1.28

19.69 10.23

1.42

18.60 9.88

1.59

18.85 13.19

1.29

17.90 12.77

1.43

16.88 12.35

1.60

17.39 12.61

1.30

16.43 12.13

1.44

15.55 11.77

1.60

17.10 15.63

1.30

16.15 15.11

1.44

15.17 15.10

1.60

16.99 16.99

1.30

16.21 16.21

1.44

15.40 15.40

1.60

21.05 11.00

1.30

19.98 10.60

1.45

18.88 10.14

1.62

19.12 13.72

1.31

18.14 13.30

1.46

17.11 12.84

1.63

17.63 13.10

1.32

16.71 12.67

1.47

15.73 12.20

1.63

17.34 16.39

1.33

16.39 16.39

1.47

15.95 15.95

1.63

17.48 17.48

1.32

16.70 16.70

1.47

15.87 15.87

1.63

H4A6S24*K*WAA* Outdoor Section With ESD4X24M14A* Indoor Section

26.83 13.50

1.67

25.48 12.99

1.87

24.11 12.32

2.08

24.67 16.40

1.69

23.40 15.85

1.87

22.07 15.29

2.08

22.78 15.85

1.69

21.62 15.31

1.87

20.34 14.76

2.08

22.35 19.32

1.69

21.34 18.88

1.88

20.11 18.14

2.08

21.73 21.72

1.69

20.80 20.80

1.87

19.86 19.86

2.08

27.35 14.01

1.72

26.14 13.38

1.91

24.56 12.79

2.13

25.02 17.30

1.73

23.82 16.64

1.92

22.46 16.07

2.13

23.31 16.55

1.74

22.00 16.06

1.92

20.80 15.42

2.13

22.82 20.48

1.74

21.63 19.92

1.92

20.42 19.29

2.13

22.56 22.56

1.74

21.58 21.58

1.92

20.58 20.58

2.13

27.76 14.45

1.76

26.46 13.81

1.96

24.79 13.20

2.18

25.49 17.95

1.77

24.15 17.40

1.96

22.72 16.80

2.18

23.63 17.30

1.78

22.36 16.74

1.97

21.06 16.09

2.18

23.24 21.50

1.78

22.21 20.48

1.97

21.19 21.19

2.18

23.13 23.13

1.78

22.32 22.32

1.97

21.16 21.16

2.18

H4A6S30*K*WAA* Outdoor Section With EVD4X30M17A* Indoor Section

32.77 16.17

2.19

30.95 15.49

2.42

29.32 14.83

2.70

29.89 19.61

2.17

28.37 19.09

2.41

26.81 18.36

2.67

27.62 18.98

2.16

26.31 18.37

2.39

24.85 17.66

2.66

27.16 23.16

2.16

25.90 22.56

2.39

24.41 21.83

2.65

26.46 26.46

2.16

25.43 25.43

2.39

24.24 24.24

2.65

33.61 16.71

2.25

31.63 15.97

2.48

29.74 15.38

2.76

30.43 20.51

2.23

28.80 19.98

2.46

27.22 19.25

2.73

28.11 19.83

2.22

26.76 19.21

2.45

25.25 18.49

2.71

27.65 24.47

2.22

26.32 23.84

2.45

24.80 23.13

2.71

27.37 27.37

2.21

26.29 26.28

2.45

25.04 25.04

2.71

34.08 17.27

2.32

32.09 16.50

2.55

30.17 15.86

2.82

31.09 21.74

2.30

29.23 20.99

2.53

27.56 20.25

2.79

28.72 20.67

2.29

27.15 20.12

2.51

25.58 19.39

2.78

28.23 25.77

2.28

26.65 25.40

2.51

25.81 25.81

2.78

28.35 28.35

2.28

27.09 27.09

2.52

25.78 25.78

2.78

115 (46.1) Capacity MBtuh
Total Sys. kW** Total Sens

17.06 15.50 14.28 14.00 14.03 17.38 15.81 14.52 14.72 14.65 17.57 15.99 14.67 15.02 15.00

9.00 11.12 10.62 13.28 14.03 9.43 11.85 11.25 14.71 14.65 9.72 12.38 11.76 15.02 15.00

1.74 1.75 1.75 1.76 1.76 1.78 1.78 1.79 1.79 1.79 1.80 1.81 1.82 1.82 1.81

22.52 20.65 19.12 18.74 18.77 22.94 20.95 19.40 19.06 19.45 23.20 21.17 19.58 19.96 19.94

11.86 14.68 14.08 17.58 18.77 12.22 15.45 14.87 19.06 19.44 12.62 16.17 15.40 19.96 19.94

2.33 2.33 2.32 2.32 2.33 2.38 2.38 2.38 2.37 2.38 2.43 2.42 2.41 2.42 2.43

27.38 25.00 23.15 22.76 22.79 27.77 25.37 23.50 23.60 23.48 28.10 25.65 23.77 24.16 24.14

14.05 17.57 16.86 21.00 22.78 14.57 18.43 17.66 23.60 23.48 15.11 19.37 18.53 24.15 24.14

3.00 2.97 2.95 2.95 2.96 3.06 3.03 3.01 3.01 3.02 3.13 3.10 3.08 3.09 3.09

125 (51.7) Capacity MBtuh
Total Sys. kW** Total Sens

15.81 8.52

1.96

14.33 10.69

1.96

13.17 10.12

1.97

13.23 13.23

1.97

13.10 13.10

1.96

16.09 8.94

2.00

14.58 11.40

2.00

13.39 10.80

2.01

13.74 13.74

2.00

13.77 13.77

2.00

16.24 9.22

2.02

14.71 11.83

2.03

13.51 11.27

2.04

13.99 13.99

2.03

14.02 14.01

2.03

20.89 11.22

2.61

19.11 14.13

2.61

17.69 13.51

2.60

17.32 17.32

2.60

17.69 17.69

2.61

21.17 11.67

2.66

19.33 14.89

2.65

17.92 14.21

2.65

18.24 18.24

2.65

18.22 18.22

2.65

21.38 11.98

2.71

19.53 15.51

2.70

18.10 14.79

2.70

18.63 18.63

2.69

18.64 18.64

2.70

25.34 13.44

3.36

23.16 16.94

3.34

21.49 16.12

3.31

21.53 21.53

3.31

21.42 21.42

3.31

25.70 13.83

3.42

23.51 17.69

3.40

21.75 16.90

3.37

22.06 22.06

3.38

22.10 22.10

3.37

25.97 14.36

3.49

23.65 18.57

3.45

21.95 17.75

3.44

22.68 22.68

3.44

22.41 22.41

3.43

H4A6S: Product Specifications
Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 13

DETAILED COOLING CAPACITIES# (Continued)

EVAPORATOR AIR

CFM

EWB

1050 1175 1350

72 (22.2) 67 (19.4) 63 (17.2) 62 (16.7) 57 (13.9) 72 (22.2) 67 (19.4) 63 (17.2) 62 (16.7) 57 (13.9) 72 (22.2) 67 (19.4) 63 (17.2) 62 (16.7) 57 (13.9)

1435 1600 1800

72 (22.2) 67 (19.4) 63 (17.2) 62 (16.7) 57 (13.9) 72 (22.2) 67 (19.4) 63 (17.2) 62 (16.7) 57 (13.9) 72 (22.2) 67 (19.4) 63 (17.2) 62 (16.7) 57 (13.9)

1435 1600 1800

72 (22.2) 67 (19.4) 63 (17.2) 62 (16.7) 57 (13.9) 72 (22.2) 67 (19.4) 63 (17.2) 62 (16.7) 57 (13.9) 72 (22.2) 67 (19.4) 63 (17.2) 62 (16.7) 57 (13.9)

75 (23.9) Capacity MBtuh
Total Sys. kW** Total Sens

40.80 37.10 34.33 33.82 32.88 41.48 37.78 34.97 34.41 33.88 42.22 38.45 35.66 35.06 35.13

19.67 24.07 23.13 28.48 32.88 20.31 25.05 24.09 29.88 33.88 21.12 26.31 25.36 31.68 35.13

2.33 2.34 2.35 2.35 2.35 2.39 2.40 2.40 2.41 2.41 2.47 2.48 2.49 2.49 2.48

54.36 49.18 45.69 44.89 43.09 54.91 50.05 46.56 45.72 44.46 56.23 51.04 47.36 46.52 45.81

27.88 33.77 32.61 39.50 43.09 28.76 35.04 33.82 41.26 44.46 29.60 36.52 35.19 43.35 45.80

3.35 3.33 3.32 3.32 3.32 3.43 3.41 3.40 3.40 3.39 3.52 3.51 3.50 3.50 3.49

56.17 50.82 47.21 46.39 44.53 56.74 51.72 48.11 47.25 45.94 58.10 52.74 48.94 48.07 47.33

27.88 33.77 32.61 39.50 44.52 28.76 35.04 33.82 41.26 45.94 29.60 36.52 35.19 43.35 47.33

3.46 3.45 3.43 3.43 3.43 3.54 3.53 3.52 3.51 3.51 3.64 3.63 3.61 3.61 3.61

CONDENSER ENTERING AIR TEMPERATURES °F (°C)

85 (29.4)

95 (35)

105 (40.6)

Capacity MBtuh

Capacity MBtuh

Capacity MBtuh

Total Sys. kW**

Total Sys. kW**

Total Sys. kW**

Total Sens

Total Sens

Total Sens

H4A6S36*K*WAA* Outdoor Section With EVD4X37M21A* Indoor Section

38.77 19.12

2.58

36.76 18.39

2.85

34.74 17.49

3.15

35.57 23.40

2.60

33.72 22.64

2.87

31.71 21.81

3.17

32.75 22.59

2.60

31.24 21.87

2.87

29.40 20.96

3.17

32.19 27.68

2.60

30.66 26.86

2.87

28.91 26.07

3.17

31.55 31.55

2.61

30.35 30.35

2.88

28.92 28.92

3.17

39.51 19.64

2.64

37.41 18.87

2.91

35.21 18.07

3.21

36.05 24.38

2.65

34.20 23.63

2.92

32.17 22.81

3.22

33.30 23.54

2.66

31.58 22.78

2.93

29.84 21.98

3.23

32.71 29.09

2.66

31.07 28.26

2.93

29.81 29.80

3.23

32.53 32.53

2.66

31.25 31.25

2.93

29.73 29.73

3.23

40.15 20.42

2.72

38.02 19.64

2.99

35.69 18.80

3.29

36.67 25.70

2.73

34.71 24.96

3.00

32.51 24.04

3.30

34.00 24.68

2.74

32.19 23.91

3.01

30.22 23.03

3.31

33.35 30.89

2.74

32.75 30.22

3.01

30.62 30.62

3.31

33.67 33.67

2.74

32.29 32.29

3.01

30.56 30.56

3.32

H4A6S42*K*WAA* Outdoor Section With EVD4X48M21A* Indoor Section

51.35 26.59

3.66

49.38 25.80

4.04

46.63 24.67

4.45

47.11 32.66

3.65

45.00 31.71

4.02

42.37 30.53

4.43

43.30 31.36

3.63

41.50 30.50

4.00

39.29 29.44

4.41

42.85 38.34

3.64

40.73 37.32

4.00

38.60 36.26

4.41

41.43 41.43

3.63

40.12 40.12

4.00

38.04 38.04

4.41

52.82 27.61

3.75

50.09 26.58

4.12

47.19 25.44

4.53

47.87 33.89

3.73

45.68 32.92

4.10

42.88 31.69

4.51

44.37 32.70

3.72

41.91 31.52

4.08

39.86 30.58

4.49

43.20 39.97

3.71

41.30 39.06

4.08

39.13 37.98

4.49

42.54 42.54

3.71

40.93 40.92

4.07

39.09 39.08

4.49

53.65 28.51

3.85

50.78 27.46

4.21

47.78 26.30

4.63

48.82 35.49

3.83

46.31 34.35

4.19

43.37 33.05

4.60

45.24 34.16

3.82

42.31 32.72

4.17

40.38 31.90

4.59

44.21 42.15

3.81

42.88 37.24

4.18

40.43 40.43

4.59

44.11 44.11

3.81

42.01 42.01

4.17

40.18 40.18

4.59

H4A6S48*K*WAA* Outdoor Section With EVD4X48M21A* Indoor Section

53.06 26.59

3.79

51.03 25.80

4.17

48.19 24.67

4.60

48.68 32.66

3.78

46.50 31.71

4.15

43.79 30.53

4.58

44.75 31.36

3.76

42.88 30.50

4.13

40.60 29.44

4.56

44.28 38.34

3.76

42.08 37.32

4.13

39.88 36.26

4.56

42.81 42.81

3.75

41.46 41.46

4.13

39.31 39.31

4.55

54.58 27.61

3.88

51.76 26.58

4.25

48.77 25.44

4.68

49.46 33.89

3.86

47.20 32.92

4.23

44.31 31.69

4.66

45.85 32.70

3.84

43.31 31.52

4.21

41.18 30.58

4.64

44.64 39.97

3.84

42.68 39.06

4.21

40.43 37.98

4.64

43.96 43.96

3.83

42.29 42.29

4.21

40.39 40.39

4.64

55.44 28.51

3.98

52.47 27.46

4.35

49.38 26.30

4.78

50.45 35.49

3.96

47.85 34.35

4.33

44.82 33.05

4.75

46.74 34.16

3.94

43.72 32.72

4.31

41.73 31.90

4.74

45.68 42.15

3.94

44.31 37.24

4.32

41.78 41.78

4.74

45.58 45.58

3.94

43.41 43.41

4.31

41.52 41.52

4.74

115 (46.1) Capacity MBtuh
Total Sys. kW** Total Sens

32.37 29.58 27.47 28.63 27.25 32.86 29.88 27.79 28.13 28.06 33.09 30.29 28.09 28.89 28.84

16.64 20.95 20.13 23.07 27.25 17.37 21.89 21.02 28.13 28.06 17.90 23.17 22.16 28.89 28.84

3.51 3.52 3.52 3.52 3.53 3.56 3.57 3.58 3.58 3.58 3.64 3.65 3.66 3.66 3.66

43.51 39.68 36.77 36.10 36.15 44.06 40.16 36.99 37.07 37.09 44.50 40.59 37.65 38.20 38.03

23.47 29.35 28.22 35.03 36.15 24.20 30.55 29.22 37.74 37.09 25.02 31.93 30.62 37.92 38.03

4.92 4.90 4.88 4.87 4.88 5.00 4.98 4.95 4.96 4.96 5.09 5.07 5.05 5.06 5.06

44.96 41.00 38.00 37.31 37.35 45.53 41.49 38.23 38.31 38.32 45.99 41.94 38.90 39.47 39.30

23.47 29.35 28.22 35.03 37.35 24.20 30.55 29.22 37.74 38.32 25.02 31.93 30.62 39.19 39.30

5.08 5.06 5.04 5.04 5.04 5.16 5.14 5.12 5.12 5.13 5.26 5.24 5.22 5.23 5.23

125 (51.7) Capacity MBtuh
Total Sys. kW** Total Sens

29.86 15.74

3.92

27.26 20.02

3.93

25.29 19.19

3.93

25.57 25.57

3.92

25.50 25.50

3.93

30.11 16.28

3.97

27.51 20.95

3.98

25.55 20.05

3.98

26.15 26.15

3.99

26.12 26.12

3.99

30.36 16.98

4.05

27.74 22.17

4.06

25.76 21.17

4.07

26.76 26.76

4.06

26.79 26.79

4.06

40.21 22.23

5.43

36.67 28.01

5.42

33.96 26.88

5.40

33.93 33.93

5.40

33.80 33.80

5.40

40.61 22.92

5.51

37.04 29.17

5.49

34.34 27.97

5.48

34.78 34.76

5.48

34.59 34.59

5.48

40.98 23.72

5.61

37.36 30.52

5.59

34.65 29.22

5.57

35.47 35.47

5.58

35.43 35.43

5.58

41.55 22.23

5.62

37.89 28.01

5.60

35.09 26.88

5.58

35.06 35.06

5.58

34.93 34.93

5.58

41.97 22.92

5.70

38.27 29.17

5.68

35.48 27.97

5.66

35.94 35.92

5.67

35.75 35.74

5.66

42.34 23.72

5.80

38.60 30.52

5.78

35.80 29.22

5.76

36.65 36.65

5.77

36.61 36.61

5.77

H4A6S: Product Specifications
Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 14

DETAILED COOLING CAPACITIES# (Continued)

EVAPORATOR AIR

CFM

EWB

75 (23.9) Capacity MBtuh
Total Sys. kW** Total Sens

1410 1600 1800

72.0 (22.2) 67.0 (19.4) 63.0 (17.2) 62.0 (16.7) 57.0 (13.9) 72.0 (22.2) 67.0 (19.4) 63.0 (17.2) 62.0 (16.7) 57.0 (13.9) 72.0 (22.2) 67.0 (19.4) 63.0 (17.2) 62.0 (16.7) 57.0 (13.9)

55.67 50.38 46.63 46.02 45.05 56.59 51.23 47.42 47.09 46.80 57.30 51.89 48.05 48.38 48.31

28.40 34.86 33.46 41.24 45.05 29.77 37.05 35.49 44.07 46.80 31.14 39.26 37.53 48.38 48.31

3.17 3.17 3.17 3.17 3.17 3.26 3.26 3.26 3.26 3.26 3.35 3.35 3.35 3.35 3.35

1765 2000 2250

72 (22.2) 67 (19.4) 63 (17.2) 62 (16.7) 57 (13.9) 72 (22.2) 67 (19.4) 63 (17.2) 62 (16.7) 57 (13.9) 72 (22.2) 67 (19.4) 63 (17.2) 62 (16.7) 57 (13.9)

68.32 62.01 57.40 56.24 54.82 69.65 63.30 58.59 57.56 56.82 70.90 64.31 59.47 58.28 58.56

33.70 41.32 39.80 48.57 54.82 34.98 43.23 41.65 51.23 56.82 36.21 45.21 43.38 54.13 58.56

4.22 4.20 4.18 4.18 4.17 4.33 4.32 4.30 4.30 4.29 4.46 4.44 4.43 4.42 4.42

CONDENSER ENTERING AIR TEMPERATURES °F (°C)

85 (29.4)

95 (35)

105 (40.6)

Capacity MBtuh

Capacity MBtuh

Capacity MBtuh

Total Sys. kW**

Total Sys. kW**

Total Sys. kW**

Total Sens

Total Sens

Total Sens

H4A6S49*K*WAA* Outdoor Section With EA*4X60L24A* Indoor Section

53.33 27.55

3.48

50.86 26.68

3.85

48.24 25.75

4.26

48.24 34.01

3.48

46.00 33.13

3.83

43.61 32.20

4.25

44.64 32.61

3.47

42.55 31.73

3.82

40.33 30.80

4.23

44.12 40.35

3.47

42.16 39.38

3.82

40.12 40.12

4.23

43.50 43.50

3.47

41.85 41.85

3.82

40.08 40.08

4.23

54.15 28.91

3.57

51.58 28.02

3.94

48.86 27.08

4.36

49.00 36.19

3.57

46.67 35.29

3.92

44.20 34.33

4.34

45.36 34.63

3.56

43.19 33.72

3.92

40.99 32.76

4.33

45.35 42.74

3.56

43.44 43.44

3.92

41.54 41.54

4.33

45.14 45.14

3.56

43.37 43.37

3.92

41.48 41.48

4.33

54.77 30.27

3.67

52.12 29.37

4.03

49.32 28.42

4.45

49.60 38.37

3.66

47.19 37.44

4.02

44.69 36.48

4.44

45.92 36.64

3.66

43.69 35.71

4.01

41.33 34.72

4.42

46.61 46.61

3.66

44.75 44.75

4.01

42.75 42.75

4.43

46.55 46.55

3.66

44.69 44.69

4.01

42.70 42.70

4.43

H4A6S60*K*WAA* Outdoor Section With EVD4X61M24A* Indoor Section

65.36 32.54

4.62

62.00 31.31

5.08

58.66 30.05

5.60

59.07 40.36

4.59

56.50 38.85

5.04

53.37 37.53

5.57

54.38 38.69

4.56

51.79 37.47

5.01

49.30 36.03

5.53

53.56 47.44

4.56

50.87 46.18

5.00

48.29 44.74

5.53

52.62 52.62

4.55

50.48 50.47

5.00

48.15 48.14

5.53

66.51 33.83

4.73

63.25 32.56

5.20

59.62 31.27

5.72

60.49 42.09

4.71

57.43 40.74

5.17

54.11 39.44

5.69

55.93 40.46

4.69

53.04 39.11

5.14

50.00 37.76

5.65

54.86 50.08

4.68

52.11 49.07

5.13

50.02 45.77

5.66

54.73 54.73

4.68

52.25 52.25

5.13

49.52 49.52

5.65

67.56 35.02

4.86

64.07 33.76

5.32

60.32 32.38

5.85

61.36 44.04

4.84

58.18 42.68

5.29

54.74 41.32

5.82

56.79 42.26

4.81

53.85 40.90

5.27

50.52 39.45

5.78

56.78 52.87

4.82

54.15 54.15

5.27

51.34 51.34

5.79

56.16 56.15

4.81

53.89 53.89

5.27

51.28 51.28

5.79

115 (46.1) Capacity MBtuh
Total Sys. kW** Total Sens

45.42 41.04 37.92 38.20 38.14 45.97 41.55 38.41 39.49 39.43 46.34 41.98 38.80 40.58 40.53

24.79 31.21 29.80 38.20 38.14 26.10 33.31 31.74 39.49 39.43 27.41 35.43 33.65 40.58 40.53

4.74 4.72 4.70 4.70 4.70 4.83 4.81 4.79 4.80 4.80 4.93 4.91 4.89 4.90 4.90

54.86 49.89 46.18 46.44 45.69 55.67 50.54 46.77 47.28 47.12 56.25 51.04 47.26 48.49 48.47

28.70 36.04 34.65 44.13 45.69 29.85 37.98 36.36 47.28 47.12 30.97 39.82 38.05 48.49 48.47

6.20 6.16 6.12 6.13 6.12 6.32 6.28 6.25 6.26 6.25 6.44 6.41 6.37 6.39 6.39

125 (51.7) Capacity MBtuh
Total Sys. kW** Total Sens

42.40 23.73

5.27

38.26 30.14

5.24

35.33 28.72

5.23

36.07 36.07

5.23

36.02 36.02

5.23

42.82 25.03

5.36

38.71 32.22

5.34

35.73 30.61

5.32

37.23 37.23

5.33

37.18 37.18

5.33

43.10 26.34

5.46

39.08 34.28

5.44

36.10 32.49

5.42

38.21 38.21

5.43

38.16 38.16

5.43

50.75 27.23

6.86

46.16 34.58

6.82

42.69 33.10

6.79

43.08 43.08

6.79

42.84 42.84

6.79

51.42 28.33

6.98

46.70 36.38

6.94

43.18 34.79

6.91

44.25 44.25

6.92

44.23 44.23

6.92

51.83 29.40

7.10

47.05 38.25

7.07

43.52 36.46

7.03

45.47 45.47

7.05

45.32 45.32

7.06

H4A6S: Product Specifications
Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 15

DETAILED COOLING CAPACITIES# (Continued)

EVAPORATOR AIR

75 (23.9)

85 (29.4)

CONDENSER ENTERING AIR TEMPERATURES °F (°C)

95 (35)

105 (40.6)

115 (46.1)

125 (51.7)

CFM

EWB

Capacity MBtuh

Capacity MBtuh

Capacity MBtuh

Capacity MBtuh

Capacity MBtuh

Capacity MBtuh

Total Sys. kW**

Total Sys. kW**

Total Sys. kW**

Total Sys. kW**

Total Sys. kW**

Total Sys. kW**

Total Sens

Total Sens

Total Sens

Total Sens

Total Sens

Total Sens

H4A6S61*K*WAA* Outdoor Section With EVD4X61M24A* Indoor Section

72 (22.2) 67.32 34.67

3.83

64.20 33.48

4.22

60.99 32.28

4.66

57.90 31.00

5.15

54.34 29.68

5.72

50.64 28.27

6.35

67 (19.4) 60.90 42.50

3.80

58.64 41.14

4.19

55.50 40.08

4.62

52.42 38.75

5.12

49.21 37.39

5.68

45.62 35.84

6.32

1800 63 (17.2) 56.36 40.94

3.78

54.06 39.62

4.17

51.28 38.52

4.59

48.35 37.20

5.09

45.29 35.88

5.65

42.13 34.30

6.28

62 (16.7) 55.24 50.04

3.78

52.84 48.82

4.16

50.32 47.80

4.59

47.69 46.92

5.08

45.54 45.54

5.65

42.78 42.78

6.29

57 (13.9) 54.18 54.18

3.78

52.35 52.35

4.16

50.05 50.05

4.59

47.86 47.86

5.08

45.41 45.41

5.65

42.67 42.67

6.29

72 (22.2) 68.30 35.79

3.93

65.12 34.59

4.31

61.99 33.35

4.75

58.61 32.05

5.25

55.02 30.70

5.82

51.12 29.27

6.45

67 (19.4) 61.98 44.30

3.90

59.29 43.17

4.28

56.24 41.80

4.72

53.07 40.45

5.21

49.71 39.07

5.77

46.11 37.51

6.41

2000 63 (17.2) 57.27 42.55

3.88

54.74 41.37

4.26

51.98 40.09

4.69

48.88 38.72

5.18

45.89 37.29

5.74

42.54 35.82

6.37

62 (16.7) 56.17 52.45

3.88

53.64 51.38

4.25

51.47 51.12

4.69

49.23 49.23

5.19

46.64 46.64

5.76

43.88 43.88

6.39

57 (13.9) 55.82 55.82

3.88

53.85 53.85

4.26

51.55 51.55

4.69

49.18 49.18

5.19

46.61 46.61

5.75

43.03 43.03

6.38

72 (22.2) 69.32 37.07

4.05

66.00 35.83

4.43

62.79 34.57

4.87

59.31 33.25

5.37

55.63 31.88

5.94

51.58 30.40

6.57

67 (19.4) 62.95 46.32

4.02

60.02 45.07

4.40

56.97 43.78

4.84

53.68 42.40

5.33

50.22 40.98

5.90

46.52 39.45

6.53

2250 63 (17.2) 58.15 44.42

4.00

55.51 43.23

4.38

52.64 41.90

4.81

49.61 40.53

5.30

46.39 39.10

5.86

42.91 37.53

6.49

62 (16.7) 57.14 55.48

3.99

56.05 55.64

4.38

53.03 53.03

4.81

50.69 50.69

5.31

47.85 47.85

5.88

44.94 44.94

6.52

57 (13.9) 57.55 57.55

4.00

55.45 55.45

4.38

53.13 53.13

4.81

50.50 50.50

5.31

47.86 47.86

5.88

44.77 44.77

6.52

{ Total and sensible capacities are net capacities based on 25 feet line set at DOE Appendix M1 test levels. } Sensible capacities shown are based on 80_F (27_C) entering air at the indoor coil. For sensible capacities at other than 80_F (27_C), deduct 835 Btuh (245 kW) per 1000 CFM (480 L/S) of indoor coil air for each degree below 80_F (27_C), or add 835 Btuh (245 kW) per 1000 CFM (480 L/S) of indoor coil air per degree above 80_F (27_C). # Detailed cooling capacities are based on indoor and outdoor unit at the same elevation per AHRI standard 210/240-2023. If additional tubing length and/or indoor unit is located above outdoor unit, a slight variation in capacity may occur. ** System kW is total of indoor and outdoor unit kilowatts. {{ At TVA rating indoor condition (75_F edb/63_F ewb). All other indoor air temperatures are at 80_F edb. NOTE: When the required data falls between the published data, interpolation may be performed. Extrapolation is not an acceptable practice. EWB -- Entering Wet Bulb

H4A6S: Product Specifications

CONDENSER ONLY RATINGS

SST °F (°C)

55.0 (12.8)

65.0 (18.3)

30.0 (-1.1)
35.0 (1.7)
40.0 (4.4)
45.0 (7.2)
50.0 (10.0)
55.0 (12.8)

TCG SDT KW TCG SDT KW TCG SDT KW TCG SDT KW TCG SDT KW TCG SDT KW

14.83 65.54 0.76 16.35 66.41 0.75 18.00 67.38 0.74 19.79 68.38 0.73 21.71 69.54 0.72 23.81 70.67 0.71

13.90 75.07 0.87 15.37 75.92 0.87 16.96 76.86 0.86 18.69 77.83 0.85 20.56 78.86 0.84 22.57 80.05 0.83

30.0 (-1.1)
35.0 (1.7)
40.0 (4.4)
45.0 (7.2)
50.0 (10.0)
55.0 (12.8)

TCG SDT KW TCG SDT KW TCG SDT KW TCG SDT KW TCG SDT KW TCG SDT KW

20.66 67.58 1.06 22.74 68.64 1.05 24.95 69.80 1.03 27.33 70.90 1.00 29.87 72.06 0.97 32.55 73.28 0.92

19.50 77.03 1.19 21.49 78.05 1.18 23.62 79.09 1.17 25.89 80.17 1.15 28.30 81.29 1.13 30.86 82.52 1.10

30.0 (-1.1)
35.0 (1.7)
40.0 (4.4)
45.0 (7.2)
50.0 (10.0)
55.0 (12.8)

TCG SDT KW TCG SDT KW TCG SDT KW TCG SDT KW TCG SDT KW TCG SDT KW

25.87 70.63 1.15 28.58 71.99 1.16 31.45 73.39 1.17 34.50 74.83 1.19 37.72 76.28 1.20 41.09 77.77 1.22

24.58 80.16 1.35 27.14 81.41 1.36 29.85 82.70 1.37 32.73 84.13 1.39 35.77 85.55 1.40 38.97 87.02 1.42

CONDENSER ENTERING AIR TEMPERATURES °F (°C)

75.0 (23.9)

85.0 (29.4)

95.0 (35.0)

H4A6S18*K*WAA* 13.04 84.64 1.00 14.45 85.46 0.99 15.98 86.33 0.98 17.63 87.30 0.97 19.42 88.30 0.96 21.36 89.35 0.95

12.21 94.24 1.13 13.55 95.02 1.13 15.01 95.86 1.12 16.58 96.79 1.11 18.29 97.74 1.10 20.14 98.74 1.09

11.37 103.83
1.28 12.65 104.58 1.28 14.03 105.37 1.27 15.52 106.25 1.27 17.13 107.16 1.26 18.89 108.11 1.25

H4A6S24*K*WAA* 18.37 86.52 1.33 20.26 87.50 1.33 22.29 88.49 1.32 24.45 89.52 1.31 26.75 90.59 1.30 29.18 91.73 1.28

17.26 95.82 1.49 19.03 96.92 1.49 20.95 97.90 1.49 23.00 98.88 1.49 25.18 99.91 1.49 27.48 101.08 1.48

16.08 105.52
1.68 17.78 106.37 1.68 19.60 107.26 1.69 21.52 108.23 1.69 23.56 109.34 1.69 25.74 110.34 1.69

H4A6S30*K*WAA* 23.14 89.60 1.55 25.55 90.78 1.56 28.11 92.06 1.57 30.84 93.32 1.58 33.72 94.71 1.60 36.75 96.14 1.61

21.61 98.97 1.75 23.86 100.21 1.76 26.29 101.34 1.77 28.87 102.52 1.78 31.60 103.79 1.80 34.46 105.18 1.82

20.02 108.29
1.96 22.15 109.36 1.97 24.41 110.58 1.99 26.85 111.71 2.01 29.43 112.90 2.03 32.14 114.14 2.05

105.0 (40.6)
10.52 113.38
1.45 11.73 113.91 1.45 13.02 114.82 1.45 14.41 115.70 1.44 15.93 116.55 1.44 17.58 117.44 1.43
14.89 114.98
1.90 16.48 115.81 1.90 18.19 116.66 1.91 20.01 117.52 1.91 21.93 118.49 1.92 23.97 119.45 1.93
18.41 117.58
2.19 20.44 118.45 2.21 22.55 119.66 2.23 24.83 120.78 2.25 27.25 121.93 2.28 29.80 123.18 2.31

115.0 (46.1)
9.62 122.93
1.65 10.74 123.58 1.65 11.95 124.28 1.65 13.27 124.93 1.64 14.67 125.86 1.64 16.21 126.73 1.64
13.63 124.48
2.16 15.06 125.28 2.16 16.68 125.78 2.16 18.42 126.87 2.17 20.22 127.74 2.18 22.13 128.60 2.19
16.75 126.79
2.46 18.68 127.76 2.49 20.67 128.79 2.52 22.80 129.93 2.55 25.07 131.01 2.58 27.47 132.12 2.61

Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 16

H4A6S: Product Specifications

CONDENSER ONLY RATINGS (Continued)

SST °F (°C)
30.0 (-1.1)
35.0 (1.7)
40.0 (4.4)
45.0 (7.2)
50.0 (10.0)
55.0 (12.8)
30.0 (-1.1)
35.0 (1.7)
40.0 (4.4)
45.0 (7.2)
50.0 (10.0)
55.0 (12.8)
30.0 (-1.1)
35.0 (1.7)
40.0 (4.4)
45.0 (7.2)
50.0 (10.0)
55.0 (12.8)

TCG SDT KW TCG SDT KW TCG SDT KW TCG SDT KW TCG SDT KW TCG SDT KW
TCG SDT KW TCG SDT KW TCG SDT KW TCG SDT KW TCG SDT KW TCG SDT KW
TCG SDT KW TCG SDT KW TCG SDT KW TCG SDT KW TCG SDT KW TCG SDT KW

55.0 (12.8)
29.51 68.00 1.28 32.53 69.08 1.29 35.75 70.32 1.31 39.23 71.49 1.32 42.95 72.76 1.33 46.92 74.03 1.33
40.38 69.06 2.13 44.47 70.37 2.15 48.89 71.77 2.16 53.64 73.28 2.17 58.72 74.91 2.19 64.15 76.66 2.20
41.73 69.10 2.22 45.96 70.40 2.23 50.52 71.81 2.24 55.43 73.33 2.26 60.68 74.96 2.27 66.29 76.71 2.29

65.0 (18.3)
27.83 77.50 1.59 30.73 78.52 1.60 33.84 79.61 1.61 37.17 80.75 1.61 40.71 82.03 1.61 44.49 83.29 1.61
38.28 78.37 2.38 42.19 79.61 2.39 46.41 80.94 2.40 50.94 82.37 2.42 55.78 83.91 2.43 60.95 85.58 2.45
39.56 78.41 2.47 43.60 79.64 2.48 47.96 80.98 2.50 52.64 82.41 2.51 57.65 83.96 2.53 62.99 85.63 2.55

CONDENSER ENTERING AIR TEMPERATURES °F (°C)

75.0 (23.9)

85.0 (29.4)

95.0 (35.0)

H4A6S36*K*WAA* 26.26 86.97 1.87 29.02 87.98 1.88 31.98 89.00 1.88 35.15 90.09 1.88 38.53 91.21 1.87 42.10 92.50 1.86

24.71 96.46 2.12 27.33 97.41 2.13 30.13 98.42 2.14 33.12 99.44 2.13 36.28 100.64 2.13 39.67 101.77 2.12

23.13 105.99
2.38 25.60 106.85 2.39 28.22 107.83 2.40 31.04 108.75 2.40 34.00 109.89 2.40 37.17 110.97 2.38

H4A6S42*K*WAA* 36.23 87.73 2.65 39.96 88.90 2.66 43.97 90.15 2.68 48.27 91.51 2.69 52.88 92.97 2.71 57.77 94.55 2.73

34.16 97.09 2.96 37.69 98.20 2.98 41.49 99.39 2.99 45.57 100.66 3.01 49.91 102.05 3.03 54.54 103.53 3.05

31.99 106.44
3.32 35.34 107.48 3.33 38.93 108.60 3.35 42.77 109.81 3.37 46.86 111.11 3.40 51.20 112.49 3.42

H4A6S48*K*WAA* 37.44 87.76 2.76 41.29 88.93 2.77 45.43 90.19 2.78 49.88 91.55 2.80 54.64 93.02 2.82 59.70 94.61 2.84

35.30 97.12 3.08 38.95 98.23 3.10 42.88 99.43 3.11 47.09 100.70 3.13 51.58 102.09 3.15 56.36 103.58 3.18

33.06 106.47
3.45 36.52 107.52 3.47 40.23 108.64 3.48 44.20 109.85 3.51 48.42 111.15 3.53 52.91 112.53 3.56

105.0 (40.6)
21.48 115.44
2.65 23.82 116.13 2.67 26.24 117.10 2.68 28.87 118.00 2.69 31.66 118.74 2.68 34.58 119.96 2.68
29.73 115.76
3.72 32.88 116.73 3.74 36.25 117.78 3.76 39.83 118.92 3.78 43.66 120.12 3.81 47.72 121.41 3.83
30.72 115.79
3.87 33.97 116.76 3.89 37.46 117.82 3.91 41.16 118.96 3.93 45.11 120.17 3.96 49.30 121.45 3.98

115.0 (46.1)
19.72 124.84
2.96 21.97 125.19 2.97 24.14 126.38 3.01 26.55 127.28 3.02 29.13 128.03 3.02 31.83 129.03 3.02
27.24 125.05
4.17 30.23 125.97 4.20 33.38 126.97 4.22 36.72 128.03 4.25 40.28 129.14 4.27 44.01 130.32 4.30
28.03 125.05
4.33 31.24 126.00 4.36 34.49 127.00 4.39 37.95 128.06 4.41 41.62 129.19 4.44 45.47 130.36 4.47

Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 17

H4A6S: Product Specifications

CONDENSER ONLY RATINGS (Continued)

SST °F (°C)

55.0 (12.8)

65.0 (18.3)

30.0 (-1.1)
35.0 (1.7)
40.0 (4.4)
45.0 (7.2)
50.0 (10.0)
55.0 (12.8)

TCG SDT KW TCG SDT KW TCG SDT KW TCG SDT KW TCG SDT KW TCG SDT KW

39.56 68.73 2.06 43.54 69.91 2.06 47.86 71.21 2.06 52.52 72.56 2.06 57.56 74.05 2.06 63.00 75.66 2.05

37.52 78.29 2.26 41.34 79.42 2.26 45.46 80.65 2.27 49.93 82.00 2.27 54.75 83.40 2.27 59.96 84.93 2.27

30.0 (-1.1)
35.0 (1.7)
40.0 (4.4)
45.0 (7.2)
50.0 (10.0)
55.0 (12.8)

TCG SDT KW TCG SDT KW TCG SDT KW TCG SDT KW TCG SDT KW TCG SDT KW

50.80 70.45 2.75 55.93 71.88 2.77 61.47 73.42 2.79 67.45 75.10 2.80 73.86 76.91 2.81 80.72 78.86 2.81

48.21 79.72 3.01 53.14 81.09 3.04 58.45 82.56 3.06 64.16 84.15 3.08 70.30 85.87 3.10 76.86 87.74 3.11

30.0 (-1.1)
35.0 (1.7)
40.0 (4.4)
45.0 (7.2)
50.0 (10.0)
55.0 (12.8)

TCG SDT KW TCG SDT KW TCG SDT KW TCG SDT KW TCG SDT KW TCG SDT KW

48.32 70.94 2.30 53.32 72.28 2.32 58.65 73.79 2.34 64.35 75.43 2.36 70.48 77.10 2.38 76.97 79.02 2.41

45.96 80.43 2.60 50.68 81.74 2.62 55.73 83.21 2.64 61.21 84.69 2.66 67.02 86.32 2.69 73.22 88.06 2.72

KW SDT SST TCG

- Outdoor Unit Kilowatts Only. -Saturated Temperature Leaving Compressor (°F) -Saturated Temperature Entering Compressor (°F/°C) -Gross Cooling Capacity (1000 Btuh)

CONDENSER ENTERING AIR TEMPERATURES °F (°C)

75.0 (23.9)

85.0 (29.4)

95.0 (35.0)

H4A6S49*K*WAA* 35.53 87.88 2.50 39.17 88.98 2.51 43.11 90.16 2.52 47.37 91.43 2.53 51.96 92.80 2.53 56.92 94.27 2.54

33.51 97.50 2.80 36.98 98.55 2.81 40.73 99.61 2.82 44.78 100.90 2.83 49.10 102.31 2.85 53.86 103.62 2.86

31.44 107.13
3.14 34.72 108.17 3.16 38.27 109.25 3.18 42.11 110.41 3.19 46.26 111.64 3.21 50.72 112.97 3.23

H4A6S60*K*WAA* 45.65 89.03 3.33 50.36 90.34 3.36 55.43 91.74 3.39 60.88 93.24 3.41 66.73 94.90 3.44 72.98 96.66 3.46

43.05 98.37 3.70 47.53 99.61 3.74 52.35 100.93 3.77 57.35 102.31 3.80 62.97 103.89 3.83 68.99 105.60 3.87

40.34 107.69
4.14 44.58 108.86 4.18 49.15 110.12 4.22 54.05 111.49 4.26 59.29 112.95 4.30 64.89 114.52 4.34

H4A6S61*K*WAA* 43.56 89.94 2.92 48.03 91.23 2.95 52.85 92.59 2.97 58.03 94.02 3.00 63.56 95.56 3.03 69.45 97.22 3.06

41.07 99.46 3.29 45.33 100.67 3.31 49.91 101.97 3.34 54.81 103.34 3.37 60.04 104.82 3.41 65.61 106.41 3.44

38.45 109.03
3.71 42.49 110.18 3.74 46.82 111.45 3.77 51.50 112.65 3.80 56.43 114.10 3.84 61.71 115.57 3.88

105.0 (40.6)
29.27 116.77
3.54 32.39 117.72 3.56 35.74 118.76 3.59 39.36 119.87 3.61 43.27 121.05 3.63 47.47 122.31 3.65
37.49 116.98
4.64 41.49 118.08 4.69 45.79 119.28 4.73 50.40 120.56 4.78 55.32 121.92 4.82 60.59 123.38 4.87
35.71 118.48
4.18 39.54 119.59 4.22 43.63 120.76 4.25 48.00 122.05 4.29 52.69 123.32 4.33 57.68 124.70 4.37

115.0 (46.1)
26.98 126.41
4.00 29.90 127.34 4.03 33.06 128.31 4.05 36.46 129.36 4.08 40.12 130.48 4.11 44.07 131.67 4.13
34.43 126.21
5.22 38.19 127.26 5.27 42.19 128.37 5.32 46.54 129.58 5.37 51.15 130.85 5.42 56.06 132.17 5.47
32.78 127.95
4.72 36.39 129.01 4.76 40.25 130.12 4.80 44.37 131.30 4.84 48.80 132.52 4.88 53.47 133.74 4.93

Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 18

H4A6S: Product Specifications
GUIDE SPECIFICATIONS GENERAL
System Description
Outdoor-mounted, air-cooled, split-system air conditioner unit suitable for ground or rooftop installation. Unit consists of a hermetic compressor, an air-cooled coil, propeller-type condenser fan, and a control box. Unit will discharge supply air upward as shown on contract drawings. Unit will be used in a refrigeration circuit to match up to a packaged fan coil or coil unit.
Quality Assurance ­ Unit will be rated in accordance with the latest edition of AHRI Standard 210/240. ­ Unit will be certified for capacity and efficiency, and listed in AHRI directory. ­ Unit construction will comply with latest edition of ANSI/ ASHRAE and with NEC. ­ Unit will be constructed in accordance with UL standards and will carry the UL label of approval. Unit will have c-UL-us approval. ­ Unit cabinet will be capable of withstanding Federal Test Method Standard No. 141 (Method 6061) 500-hr salt spray test. ­ Air-cooled condenser coils will be leak tested at 150 psig and pressure tested at 470 psig. ­ Unit constructed in ISO9001 approved facility.
Delivery, Storage, and Handling ­ Unit will be shipped as single package only and is stored and handled per unit manufacturer's recommendations.
Warranty (for inclusion by specifying engineer) ­ U.S. and Canada only.
PRODUCTS
Equipment
Factory assembled, single piece, air-cooled air conditioner unit. Contained within the unit enclosure is all factory wiring, piping, controls, compressor, refrigerant charge R-410A, and special features required prior to field start-up.
Unit Cabinet ­ Unit cabinet will be constructed of galvanized steel, bonderized, and coated with a powder coat paint.
Fans ­ Condenser fan will be direct-drive propeller type, discharging air upward. ­ Condenser fan motors will be totally enclosed, 1-phase type with class B insulation and permanently lubricated bearings. Shafts will be corrosion resistant. ­ Fan blades will be statically and dynamically balanced. ­ Condenser fan openings will be equipped with coated steel wire safety guards.

Air-cooled, split-system air conditioner H4A6S
1-1/2 to 5 nominal tons
Compressor ­ Compressor will be hermetically sealed. ­ Compressor will be mounted on rubber vibration isolators.
Condenser Coil ­ Condenser coil will be air cooled. ­ Coil will be constructed of aluminum fins mechanically bonded to copper or aluminum tubes which are then cleaned, dehydrated, and sealed.
Refrigeration Components ­ Refrigeration circuit components will include liquid-line shutoff valve with sweat connections, vapor-line shutoff valve with sweat connections, system charge of R-410Arefrigerant, and compressor oil. ­ Unit will be equipped with low and high pressure switches and shipped with filter drier for R-410A refrigerant.
Operating Characteristics ­ The capacity of the unit will meet or exceed _____ Btuh at a suction temperature of _____ _F/_C. The power consumption at full load will not exceed _____ kW. ­ Combination of the unit and the evaporator or fan coil unit will have a total net cooling capacity of _____ Btuh or greater at conditions of _____ CFM entering air temperature at the evaporator at _____ _F/_C wet bulb and _____ _F/_C dry bulb, and air entering the unit at _____ _F/_C. ­ The system will have a SEER2 of _____ Btuh/watt or greater at DOE conditions.
Electrical Requirements ­ Nominal unit electrical characteristics will be _____ v, single phase, 60 Hz. The unit will be capable of satisfactory operation within voltage limits of _____ v to _____ v. ­ Nominal unit electrical characteristics will be _____ v, three phase, 60 Hz. The unit will be capable of satisfactory operation within voltage limits of _____ v to _____ v. ­ Unit electrical power will be single point connection. ­ Control circuit will be 24v.
Special Features ­ Refer to section of this literature identifying accessories and descriptions for specific features and available enhancements.

Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 19

H4A6S: Product Specifications

© 2022 Carrier. All rights reserved. A Carrier Company www.GoHeil.com

Edition Date: 07/22

7Catalog No:H4A6S-11-02PD
Replaces: H4A6S-11-01PD

Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 20

