ETSI 301 489-17 V1

Sem

Antenna Spec

L&S; Italia S.p.A. SMARTUP1 Remote Control 2ARW2-SMARTUP1 2ARW2SMARTUP1 smartup1

PDF Viewing Options

Not Your Device? Search For Manuals or Datasheets below:


File Info : application/pdf, 11 Pages, 1.02MB

Document DEVICE REPORTGetApplicationAttachment.html?id=7389110
TEST REPORT

Reference No....................... : Applicant............................... : Address................................. : Manufacturer........................ : Address................................. : Product Name...................... : Model No............................... :

WTF24X04070923W L&S ltalia SpA Viale Lino Zanussi, 8-33070 Maron di Brugnera (PN)-ITALY Nexta Tech - Brand of TEAM srl Via Gugliermo Oberdan, 90 - 33074 Fontanafredda (PN) - ITALY Remote Control SMART UP 1

Standards.............................. : ANSI/ IEEE 149-2021

Date of Receipt sample..... : Date of Test........................... : Date of Issue........................ : Test Report Form No.......... : Test Result............................ :

2024-04-01 2024-04-01 to 2024-04-17 2024-04-17 WTX_IEEE 149 Pass

Remarks: The results shown in this test report refer only to the sample(s) tested, this test report cannot be reproduced, except in full, without prior written permission of the company. The report would be invalid without specific stamp of test institute and the signatures of approver.
Prepared By: Waltek Testing Group (Shenzhen) Co., Ltd. Address: 1/F., Room 101, Building 1, Hongwei Industrial Park, Liuxian 2nd Road, Block 70 Bao'an District, Shenzhen, Guangdong, China Tel.: +86-755-33663308 Fax.: +86-755-33663309 Email: [email protected]

Tested by:

Approved by:

Dashan Chen

Jason Su

Waltek Testing Group (Shenzhen) Co., Ltd.

Http://www.waltek.com.cn

Page 1 of 11

Reference No.: WTF24X04070923W
TABLE OF CONTENTS
1.GENERAL INFORMATION .................................................................................................................................... 4 1.1 PRODUCT DESCRIPTION FOR EQUIPMENT UNDER TEST (EUT) ............................................................................. 4
2. SUMMARY OF TEST RESULTS ............................................................................................................................5
3. ANTENNA TEST CONFIGURATIONS .................................................................................................................6 3.1 TEST LOCATION ......................................................................................................................................................6 3.2 TEST ENVIRONMENTS .............................................................................................................................................6 3.3 TEST EQUIPMENT LIST ........................................................................................................................................... 6 3.4 MEASUREMENT UNCERTAINTY .............................................................................................................................. 6 3.5 TEST SETUP ............................................................................................................................................................ 6
4. ANTENNA TEST RESULT ...................................................................................................................................... 7 4.1 GAIN AND EFFICIENCY ........................................................................................................................................... 7 4.2 RADIATION PATTERN 2D VIEW ............................................................................................................................... 8 4.3 RADIATION PATTERN 3D VIEW ............................................................................................................................... 9
EXHIBIT 1 - EUT PHOTOGRAPHS ........................................................................................................................ 10
EXHIBIT 2 - TEST SETUP PHOTOGRAPHS ........................................................................................................ 11

Waltek Testing Group (Shenzhen) Co., Ltd.

Http://www.waltek.com.cn

Page 2 of 11

Reference No.: WTF24X04070923W

Report version

Version No. Rev.00 /

Date of issue 2024-04-17
/

Description Original /

Waltek Testing Group (Shenzhen) Co., Ltd.

Http://www.waltek.com.cn

Page 3 of 11

Reference No.: WTF24X04070923W

1.GENERAL INFORMATION

1.1 Product Description for Equipment Under Test (EUT)

General Description of EUT

Product Name:

Remote Control

Trade Name:

/

Model No.:

SMART UP 1

Adding Model(s):

SMART UP 1 MONO

Note: The test data is gathered from a production sample, provided by the manufacturer. The

appearance of others models listed in the report is different from main-test model SMART UP 1, but the

circuit and the electronic construction do not change, declared by the manufacturer.

Technical Characteristics of EUT Frequency Range: Gain of Antenna: Type of Antenna:

400-500MHz -15.69dBi (Max.) PCB Antenna

Dimension:

Waltek Testing Group (Shenzhen) Co., Ltd.

Http://www.waltek.com.cn

Page 4 of 11

Reference No.: WTF24X04070923W
2. SUMMARY OF TEST RESULTS

Standards ANSI/ IEEE 149-2021
N/A: not applicable

Description of Test Item IEEE Recommended Practice for Antenna
Measurements

Result Compliant

Waltek Testing Group (Shenzhen) Co., Ltd.

Http://www.waltek.com.cn

Page 5 of 11

Reference No.: WTF24X04070923W
3. Antenna Test Configurations

3.1 Test Location

Name: Address:

Shenzhen Morlab Communications Technology Co.,Ltd.
FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen, GuangDong Province, P.R. China

3.2 Test Environments

Environments Parameter NTNV
3.3 Test Equipment List

Temperature 25 C

Voltage --

Humidit 50%

Description Network Analyzer
OTA Chamber Antenna Measurement
System

Manufacturer Agilent ETS
ETS

Model E5071C AMS-8923-150 EMQuest EMQ-100 V1.13 Build 21267

Serial Number MY46110140 TJ2235-Q1793
1685

Cal. Date 2023-06-21 2022-11-30
N/A

Due. Date 2024-06-20 2025-11-29
N/A

3.4 Measurement Uncertainty

The uncertainty is calculated using the methods suggested in the"Guide to the Expression of Uncertainty in Measurement" (GUM) published by ISO. When the test result is a critical value,we will use the measurement uncertainty give the judgment result based on the 95%Confidence intervals.
3.5 Test Setup

Waltek Testing Group (Shenzhen) Co., Ltd.

Http://www.waltek.com.cn

Page 6 of 11

Reference No.: WTF24X04070923W
4. Antenna Test Result
4.1 Gain and Efficiency
Frequency(MHz) 400 410 420 430 440 450 460 470 480 490 500

Gain(dBi)
-16.99 -16.48 -15.69 -17.65 -16.20 -16.80 -16.96 -17.52 -15.87 -17.22 -15.87

Efficiency (%)
0.54 0.52 0.47 0.41 0.48 0.44 0.52 0.48 0.53 0.50 0.48

Waltek Testing Group (Shenzhen) Co., Ltd.

Http://www.waltek.com.cn

Page 7 of 11

Reference No.: WTF24X04070923W 4.2 Radiation Pattern 2D View EUT #1:

PHI=0

PHI=90

THETA=90

Waltek Testing Group (Shenzhen) Co., Ltd.

Http://www.waltek.com.cn

Page 8 of 11

Reference No.: WTF24X04070923W 4.3 Radiation Pattern 3D View

400MHz

. 450MHz

500MHz

Waltek Testing Group (Shenzhen) Co., Ltd.

Http://www.waltek.com.cn

Page 9 of 11

Reference No.: WTF24X04070923W
EXHIBIT 1 - EUT PHOTOGRAPHS
EUT View 1

Waltek Testing Group (Shenzhen) Co., Ltd.

Http://www.waltek.com.cn

Page 10 of 11

Reference No.: WTF24X04070923W
EXHIBIT 2 - TEST SETUP PHOTOGRAPHS
OTA Test View 1:
OTA Test View 2:

***** END OF REPORT *****

Waltek Testing Group (Shenzhen) Co., Ltd.

Http://www.waltek.com.cn

Page 11 of 11

