Sam Lin

CN22L8D1 001 FCC 15B Impacta 68i extsigned

Intelbras Industria de Telecomunicacao Eletronica Brasileira IMPACTA68I Impacta 68i 2A76R-IMPACTA68I 2A76RIMPACTA68I impacta68i

PDF Viewing Options

Not Your Device? Search For Manuals or Datasheets below:


File Info : application/pdf, 18 Pages, 1.22MB

Document DEVICE REPORTGetApplicationAttachment.html?id=6100419
Prüfbericht - Produkte Test Report - Products
Prüfbericht-Nr.: Test report no.:
Kunden-Referenz-Nr.: Client reference no.:
Auftraggeber: Client:
Prüfgegenstand: Test item:
Bezeichnung / Typ-Nr.: Identification / Type no.:
Auftrags-Inhalt: Order content:
Prüfgrundlage: Test specification:

CN22L8D1 001

Auftrags-Nr.: Order no.:

168374470

N/A

Auftragsdatum: 2022-05-26

Order date:

Intelbras Industria de Telecomunicacao Eletronica Brasileira Rodovia BR 101 KM 210 Area Industrial Sao Jose Brazil

Impacta exchanges

Impacta 68i

Test Report

FCC CFR Title 47, Part 15, Subpart B

Seite 1 von 18 Page 1 of 18

Wareneingangsdatum: 2022-06-27 Date of sample receipt:

Prüfmuster-Nr.: Test sample no:

A003285007-001 A003285010-001 A003285800-001~013

Prüfzeitraum: Testing period:

2022-07-14 ­ 2022-08-21

Please refer to Photo Document

Ort der Prüfung: Place of testing:

TÜV Rheinland (Shenzhen) Co., Ltd.

Prüflaboratorium: Testing laboratory:

TÜV Rheinland (Shenzhen) Co., Ltd.

Prüfergebnis*: Test result*:

Pass

geprüft von: tested by:
Datum: Date: 2022-08-30 Stellung / Position:
Sonstiges / Other:

X
Signed by: Bell Hu
Project Manager FCC ID: 2A76R-IMPACTA68I

genehmigt von: authorized by:
Ausstellungsdatum: Issue date: 2022-08-30

X
Signed by: Lin Lin

Stellung / Position:

Reviewer

Zustand des Prüfgegenstandes bei Anlieferung: Condition of the test item at delivery:

Prüfmuster vollständig und unbeschädigt Test item complete and undamaged

* Legende: * Legend:

1 = sehr gut

2 = gut

P(ass) = entspricht o.g. Prüfgrundlage(n)

1 = very good

2 = good

P(ass) = passed a.m. test specification(s)

3 = befriedigend F(ail) = entspricht nicht o.g. Prüfgrundlage(n)
3 = satisfactory F(ail) = failed a.m. test specification(s)

4 = ausreichend
N/A = nicht anwendbar 4 = sufficient N/A = not applicable

5 = mangelhaft
N/T = nicht getestet 5 = poor N/T = not tested

Dieser Prüfbericht bezieht sich nur auf das o.g. Prüfmuster und darf ohne Genehmigung der Prüfstelle nicht auszugsweise vervielfältigt werden. Dieser Bericht berechtigt nicht zur Verwendung eines Prüfzeichens.
This test report only relates to the a. m. test sample. Without permission of the test center this test report is not permitted to be duplicated in extracts. This test report does not entitle to carry any test mark.

TÜV Rheinland (Shenzhen) Co., Ltd. 1601 R&D Room, 1602-1604, 17-18F, Building 7 Site C, Vanke Cloud City Phase I, Xingke First Street, Xili Street, Xili Community, Nanshan District, Shenzhen 518052, P.R. China Mail: [email protected] ·Web: www.tuv.com
jjj

Prüfbericht - Produkte Test Report - Products
Prüfbericht - Nr.:
Test Report No.:

CN22L8D1 001

Test Summary
5.1.1 CONDUCTED EMISSION ON AC MAINS RESULT: Pass
5.1.2 RADIATED EMISSIONS RESULT: Pass

Seite 2 von 18 Page 2 of 18

Prüfbericht - Produkte Test Report - Products
Prüfbericht - Nr.:
Test Report No.:

CN22L8D1 001

Seite 3 von 18 Page 3 of 18

Table of Contents

1

GENERAL REMARKS ...........................................................................................................................4

1.1 COMPLEMENTARY MATERIALS ............................................................................................................4

2

TEST SITES ........................................................................................................................................5

2.1 TEST FACILITIES .................................................................................................................................5

2.2 LIST OF TEST AND MEASUREMENT INSTRUMENTS.................................................................................5

2.3 TRACEABILITY ....................................................................................................................................5

2.4 CALIBRATION .....................................................................................................................................5

2.5 MEASUREMENT UNCERTAINTY.............................................................................................................6

2.6 LOCATION OF ORIGINAL DATA.............................................................................................................6

2.7 STATUS OF FACILITY USED FOR TESTING.............................................................................................6

3

GENERAL PRODUCT INFORMATION ......................................................................................................7

3.1 PRODUCT FUNCTION AND INTENDED USE.............................................................................................7

3.2 RATINGS AND SYSTEM DETAILS ..........................................................................................................7

3.3 INDEPENDENT OPERATION MODES ......................................................................................................7

3.4 NOISE GENERATING AND NOISE SUPPRESSING PARTS .........................................................................7

3.5 SUBMITTED DOCUMENTS.....................................................................................................................7

4

TEST SET-UP AND OPERATION MODES ................................................................................................8

4.1 PRINCIPLE OF CONFIGURATION SELECTION .........................................................................................8

4.2 TEST OPERATION AND TEST SOFTWARE ..............................................................................................8

4.3 SPECIAL ACCESSORIES AND AUXILIARY EQUIPMENT ............................................................................8

4.4 COUNTERMEASURES TO ACHIEVE EMC COMPLIANCE ..........................................................................8

4.5 TEST SETUP DIAGRAM ........................................................................................................................9

5

TEST RESULTS .................................................................................................................................10

5.1.1 Conducted Emission on AC Mains.............................................................................................10

5.1.2 Radiated Emissions....................................................................................................................13

6

PHOTOGRAPHS OF THE TEST SET-UP ................................................................................................18

7

LIST OF TABLES................................................................................................................................18

Prüfbericht - Produkte Test Report - Products

Prüfbericht - Nr.:
Test Report No.:

CN22L8D1 001

1 General Remarks

Seite 4 von 18 Page 4 of 18

1.1 Complementary Materials
All attachments are integral parts of this test report. This applies especially to the following appendix: Appendix A: Photographs of the Test Set-up

Prüfbericht - Produkte Test Report - Products
Prüfbericht - Nr.:
Test Report No.:
2 Test Sites

CN22L8D1 001

Seite 5 von 18 Page 5 of 18

2.1 Test Facilities
TÜV Rheinland (Shenzhen) Co., Ltd. 362 Huanguan Road Middle Longhua District, Shenzhen 518110 People's Republic of China
FCC Accreditation Designation No.: CN1260

2.2 List of Test and Measurement Instruments

Table 1: List of Test and Measurement Equipment

Conducted Emission

Equipment

Manufacturer

EMI Test Receiver

R&S

Artificial Mains Network
Artificial Mains Network

R&S R&S

EMC32 test software

R&S

Radiated Emission (3m chamber)

Equipment

Manufacturer

3m SAC

ETS-Lindgren

EMI Test Receiver

R&S

Horn Antenna

R&S

Preamplifier (1-18GHz)
Trilog-Broadband antenna

FIT SCHWARZBECK

EMC32 test software

R&S

Model No. ESR3
ENV216
ENV432 EMC32(Ver.10.50.00)
Model No. SAC3 ESR7 HF907
SCU-18F
VULB9168 EMC32(Ver.10.50.00)

Serial No. 102680 101445
101546 N/A
Serial No. CT001632-Q1362
102111 102706 180077
0945 N/A

Cal. Until 2023-02-27 2023-02-27
2023-02-27 N/A
Cal. Until 2024-04-26 2022-12-01 2022-08-07 2022-08-13
2022-12-12 N/A

2.3 Traceability
All measurement equipment calibrations are traceable to NIM (National Institute of Metrology) or where calibration is performed in other countries, to equivalent nationally recognized standards organizations.
2.4 Calibration
Equipment requiring calibration is calibrated periodically by the manufacturer or according to manufacturer's specifications. Additionally all equipment is verified for proper performance on a regular basics using in house standards or comparisons.

Prüfbericht - Produkte Test Report - Products

Prüfbericht - Nr.:
Test Report No.:

CN22L8D1 001

Seite 6 von 18 Page 6 of 18

2.5 Measurement Uncertainty
The estimated combined standard uncertainty for radiated emissions and conducted emissions measurements as below table.

Parameter Radiated Emission (3m SAC), 30MHz to 1000MHz Radiated Emission (3m SAC), above 1000MHz Conducted Emission, (9kHz to 150kHz)/(150kHz to 30MHz)

Uncertainty ± 4.52 dB ± 4.37 dB
± 3.70 dB / ± 3.30 dB

2.6 Location of Original Data
The original copies of all test data taken during actual testing were attached at Appendix A of this report and delivered to the applicant. A copy has been retained in the TÜV Rheinland (Shenzhen) Co., Ltd. file for certification follow-up purposes.
2.7 Status of Facility Used for Testing
The TÜV Rheinland (Shenzhen) Co., Ltd. Test facility located at 362 Huanguan Road Middle Longhua District, Shenzhen 518110 People's Republic of China is listed on the US Federal Communications Commission list of facilities approved to perform measurements.

Prüfbericht - Produkte Test Report - Products

Prüfbericht - Nr.:
Test Report No.:

CN22L8D1 001

3 General Product Information

3.1 Product Function and Intended Use
The EUT is an Impacta exchanges. For details refer to the User Manual, Technical Description and Circuit Diagram.

3.2 Ratings and System Details

Table 2: Technical Specification of EUT

General Information of EUT Kind of Equipment: Type Designation: FCC ID: Operating Voltage: Operating Temperature Range: Equipement Class:

Value Impacta exchanges Impacta 68i 2A76R-IMPACTA68I AC 120V, 60Hz 0 °C ~ +45 °C Class A digital device (JAD)

Seite 7 von 18 Page 7 of 18

3.3 Independent Operation Modes
The basic operation modes are: A. On, Normal working B. Off

3.4 Noise Generating and Noise Suppressing Parts
Refer to Circuit Diagram for further details.

3.5 Submitted Documents
- User Manual - ID Label and Location Info - Schematics

- Operation Description - Block Diagram - PCB Layout

Prüfbericht - Produkte Test Report - Products

Prüfbericht - Nr.:
Test Report No.:

CN22L8D1 001

4 Test Set-up and Operation Modes

Seite 8 von 18 Page 8 of 18

4.1 Principle of Configuration Selection
Emission: The equipment under test (EUT) was configured to measure its highest possible radiation level. The test modes were adapted accordingly in reference to the instructions for use.
4.2 Test Operation and Test Software
Test operation refers to test setup in chapter 5. All tests were performed according to the procedures in ANSI C63.4: 2014. According to clause 3.1, all tests were performed on model Impacta 68i in this report.

4.3 Special Accessories and Auxiliary Equipment

Table 3: Auxiliary Equipment Used during Test

Description

Manufacturer

Model

Smart terminal

Intelbras

TI5000

S/N

Remark

N/A

Connecting with Impacta 68i

4.4 Countermeasures to Achieve EMC Compliance
The test sample which has been tested contained the noise suppression parts as described in the Technical Construction File (TCF). No additional measures were employed to achieve compliance.

Prüfbericht - Produkte Test Report - Products
Prüfbericht - Nr.:
Test Report No.:

CN22L8D1 001

4.5 Test Setup Diagram

Diagram of Measurement Configuration for Radiation Test (Below 1GHz)

Seite 9 von 18 Page 9 of 18

Diagram of Measurement Configuration for Radiation Test (Above 1GHz)

Diagram of Measurement Configuration for Mains Conduction Measurement

Prüfbericht - Produkte Test Report - Products

Prüfbericht - Nr.:
Test Report No.:

CN22L8D1 001

5 Test Results

5.1.1 Conducted Emission on AC Mains

RESULT:

Test Specification Test standard Basic standard Frequency range Classification Limits Kind of test site

: FCC Part 15.107(a) : ANSI C63.4:2014 : 0.15 ­ 30MHz : Class A : FCC Part 15.107(a) : Shielded Room

Test Setup Date of testing Input voltage Operation mode Ambient temperature Relative humidity Atmospheric pressure

: 2022-07-14 : AC 120V, 60Hz : A : 24.1  : 52.8 % : 101 kPa

For the measurement records, refer to the following plots.

Seite 10 von 18 Page 10 of 18
Pass

Prüfbericht - Produkte Test Report - Products
Prüfbericht - Nr.:
Test Report No.:

CN22L8D1 001

EUT Information
EUT Name: Order No: Model: Test mode: Test Voltage: Test By:/Review By: Test Standard: Tem./Hum./Pressure: Remark:

Impacta exchanges 168374467 Impacta 68i ON, Normal working AC 120V/50Hz Kevin Zhou/Gary Chen FCC Part 15B 24.1°C/52.8%//101kPa SR2

Seite 11 von 18 Page 11 of 18

Level in dB

Critical_Freqs

Frequency (MHz)

MaxPeak (dBuV)

0.198000 0.198000 0.278000

--53.38 45.30

0.278000 9.002000 9.174000 13.293500

----47.28 ---

13.557500 16.893500 16.961500

58.14 58.69
---

24.433500 24.529500

--57.55

Average (dBuV)
39.34 -----
27.79 36.29
--42.55
----46.33 42.89 ---

Limit (dBuV)
53.69 63.69 60.88 50.88 50.00 60.00 50.00 60.00 60.00 50.00 50.00 60.00

Margin (dB)
14.35 10.31 15.58 23.09 13.71 12.72
7.45 1.86 1.31 3.67 7.11 2.45

Line
L1 L1 L1 L1 L1 L1 L1 L1 L1 L1 L1 L1

Corr. (dB)
9.9 9.9 9.9 9.9 10.3 10.3 10.4 10.4 10.4 10.4 10.4 10.4

Final_Result

Frequency (MHz)

QuasiPeak (dBuV)

13.293500

---

13.557500

51.39

16.893500

52.73

16.961500

---

24.433500

---

24.529500

50.79

Average (dBuV)
41.25 -----
44.29 40.69
---

Limit (dBuV)
50.00 60.00 60.00 50.00 50.00 60.00

Margin (dB)
8.75 8.61 7.27 5.71 9.31 9.21

Meas. Time (ms)
3000.0 3000.0 3000.0 3000.0 3000.0 3000.0

Bandwidth (kHz)
9.000 9.000 9.000 9.000 9.000 9.000

Line
L1 L1 L1 L1 L1 L1

Corr. (dB)
10.4 10.4 10.4 10.4 10.4 10.4

Prüfbericht - Produkte Test Report - Products
Prüfbericht - Nr.:
Test Report No.:

CN22L8D1 001

EUT Information
EUT Name: Order No: Model: Test mode: Test Voltage: Test By:/Review By: Test Standard: Tem./Hum./Pressure: Remark:

Impacta exchanges 168374467 Impacta 68i ON, Normal working AC 120V/50Hz Kevin Zhou/Gary Chen FCC Part 15B 24.1°C/52.8%//101kPa SR2

Seite 12 von 18 Page 12 of 18

Level in dB

Critical_Freqs

Frequency (MHz)

MaxPeak (dBuV)

0.202000 0.206000 0.266000

--54.13
---

0.270000 8.918000 9.042000 12.374000

47.91 ---
47.85 47.98

12.750000 16.229500 16.537500

----52.58

25.342000 25.578000

52.09 ---

Average (dBuV)
37.63 ---
29.62 ---
36.68 -----
37.77 42.65
----38.06

Limit (dBuV)
53.53 63.37 51.24 61.12 50.00 60.00 60.00 50.00 50.00 60.00 60.00 50.00

Margin (dB)
15.90 9.24
21.62 13.20 13.32 12.15 12.02 12.23
7.35 7.42 7.91 11.94

Line
N N N N N N N N N N N N

Corr. (dB)
9.8 9.8 9.8 9.8 10.0 10.0 10.1 10.1 10.2 10.2 10.3 10.3

Final_Result

Frequency (MHz)

QuasiPeak (dBuV)

16.229500

---

16.537500

47.01

Average (dBuV)
42.38 ---

Limit (dBuV)
50.00 60.00

Margin (dB)
7.62 12.99

Meas. Time (ms)
3000.0 3000.0

Bandwidth (kHz)
9.000 9.000

Line
N N

Corr. (dB)
10.2 10.2

Prüfbericht - Produkte Test Report - Products

Prüfbericht - Nr.:
Test Report No.:

CN22L8D1 001

Seite 13 von 18 Page 13 of 18

5.1.2 Radiated Emissions

RESULT:

Pass

Test Specification Test standard Basic standard Frequency range Classification Limits Kind of test site

: FCC Part 15.109(a) : ANSI C63.4:2014 : 30MHz to 5th harmonic of the highest frequency : Class A : FCC Part 15.109(a) : 3m Semi-anechoic Chamber

Test Setup Date of testing Input voltage Operation mode Ambient temperature Relative humidity Atmospheric pressure

: 2022-07-26 to 2022-08-21 : AC 120V, 60Hz : A : Refer to test result : Refer to test result : 101 kPa

For the measurement records, refer to the following plots. As for above 6GHz, only the noise-floors, thus no record for it.

Prüfbericht - Produkte Test Report - Products
Prüfbericht - Nr.:
Test Report No.:

CN22L8D1 001

EUT Information
EUT Name: Order No: Model: Test Mode: Test Voltage: Standard: Test By:/Review By: Tem./Hum./Pressure: Remark:

Impacta exchanges 168374467 30 Impacta 68i ON, Normal working AC 120V/60Hz FCC Part 15 Kevin Zhou/Gary Chen 24.1°C/55.3%/101kPa 3m chamber

Seite 14 von 18 Page 14 of 18

Level in dB/m

Critical_Freqs

Frequency (MHz)

MaxPeak

Limit

Margin Height Pol

(dBuV/m) (dBuV/m) (dB) (cm)

94.408000

37.03

53.50 16.47 100.0 V

124.963000

36.96

53.50 16.54 100.0 V

154.548000

38.43

53.50 15.07 100.0 V

245.728000

37.52

56.00 18.48 100.0 V

368.590000

48.03

56.00

7.73 100.0 V

840.047000

42.03

56.00 13.97 100.0 V

Azimuth (deg)
77.0 85.0 272.0 152.0 124.0 149.0

Corr. (dB/m)
16.2 19.1 21.4 18.6 22.9 31.3

Final_Result

Frequency (MHz)

QuasiPea k
(dBuV/m)

368.590000

41.92

Limit (dBuV/m
)
56.00

Margin (dB)
14.08

Meas. Time (ms)

Bandwid Height Pol

th

(cm)

(kHz)

1000.0 120.000 100.0 V

Azimuth Corr. (deg) (dB/m)

124.0

22.9

Prüfbericht - Produkte Test Report - Products
Prüfbericht - Nr.:
Test Report No.:
EUT Information
EUT Name: Order No: Model: Test Mode: Test Voltage: Standard: Test By:/Review By: Tem./Hum./Pressure: Remark:

CN22L8D1 001
Impacta exchanges 168374467 30 Impacta 68i ON, Normal working AC 120V/60Hz FCC Part 15 Kevin Zhou/Gary Chen 24.1°C/55.3%/101kPa 3m chamber

Seite 15 von 18 Page 15 of 18

Level in dB/m

Critical_Freqs

Frequency (MHz)

MaxPeak

Limit

Margin Height Pol

(dBuV/m) (dBuV/m) (dB) (cm)

183.939000 245.728000

40.80 44.15

53.50 56.00

12.70 11.85

200.0 H 100.0 H

368.590000 499.965000

57.60 41.39

56.00 56.00

-1.60 14.61

100.0 H 100.0 H

599.972000 840.047000

43.97 44.73

56.00 56.00

12.03 11.27

100.0 H 100.0 H

Azimuth (deg)
289.0 20.0
255.0 118.0 153.0 137.0

Corr. (dB/m)
18.5 18.6 22.9 25.6 28.1 31.3

Final_Result

Frequency (MHz)

QuasiPea k
(dBuV/m)

368.590000

51.05

Limit (dBuV/m
)
56.00

Margin (dB)
4.95

Meas. Time (ms)

Bandwid Height Pol

th

(cm)

(kHz)

1000.0 120.000 100.0 H

Azimuth Corr. (deg) (dB/m)

255.0

22.9

Prüfbericht - Produkte Test Report - Products
Prüfbericht - Nr.:
Test Report No.:
EUT Information
EUT Name: Order No: Model: Test Mode: Test Voltage: Standard: Test By:/Review By: Tem./Hum./Pressure: Remark:

CN22L8D1 001
Impacta exchanges 168374467 30 Impacta 68i ON, Normal working AC 120V/60Hz FCC Part 15B Kevin Zhou/Gary Chen 24.1°C/51.3%/101kPa 3m chamber

Seite 16 von 18 Page 16 of 18

Level in dB/m

Critical_Freqs

Frequency (MHz)

MaxPeak Average

Limit Margin Height Pol

(dBuV/m) (dBuV/m) (dBuV/m) (dB)

(cm)

1080.000000 1080.000000

37.58 ---

--36.84

79.50 59.50

41.92 22.66

100.0 V 100.0 V

1320.000000 1320.000000

41.57 ---

--41.03

79.50 59.50

37.93 18.47

100.0 V 100.0 V

1440.000000 1440.000000 1594.500000

38.70 ---
37.10

--37.38
---

79.50 59.50 79.50

40.81 22.12 42.40

100.0 V 100.0 V 100.0 V

1594.500000 1680.000000 1680.000000

--36.87
---

35.06 ---
34.38

59.50 79.50 59.50

24.44 42.63 25.12

100.0 V 100.0 V 100.0 V

2312.500000 2312.500000

39.71 ---

--38.68

79.50 59.50

39.79 20.82

100.0 V 100.0 V

Azimuth (deg)
220.0 220.0 147.0 147.0 158.0 158.0
0.0 0.0 202.0 202.0 325.0 325.0

Corr. (dB/m)
-12.8 -12.8 -13.4 -13.4 -12.6 -12.6 -10.3 -10.3
-9.5 -9.5 -6.5 -6.5

Prüfbericht - Produkte Test Report - Products
Prüfbericht - Nr.:
Test Report No.:
EUT Information
EUT Name: Order No: Model: Test Mode: Test Voltage: Standard: Test By:/Review By: Tem./Hum./Pressure: Remark:

CN22L8D1 001
Impacta exchanges 168374467 30 Impacta 68i ON, Normal working AC 120V/60Hz FCC Part 15B Kevin Zhou/Gary Chen 24.1°C/51.3%/101kPa 3m chamber

Seite 17 von 18 Page 17 of 18

Level in dB/m

Critical_Freqs

Frequency (MHz)

MaxPeak Average

Limit Margin Height Pol

(dBuV/m) (dBuV/m) (dBuV/m) (dB)

(cm)

1080.000000 1080.000000

42.04 ---

--41.45

79.50 59.50

37.46 18.05

100.0 H 100.0 H

1105.500000 1106.000000

36.63 ---

--35.23

79.50 59.50

42.87 24.27

100.0 H 100.0 H

1320.000000 1320.000000 1560.000000

40.57 -----

--39.80 42.93

79.50 59.50 59.50

38.93 19.70 16.57

100.0 H 100.0 H 100.0 H

1560.000000 1800.000000 1800.000000

43.83 ---
40.73

--40.33
---

79.50 59.50 79.50

35.67 19.17 38.77

100.0 H 100.0 H 100.0 H

2040.000000 2040.500000

41.69 ---

--40.86

79.50 59.50

37.81 18.64

100.0 H 100.0 H

Azimuth (deg)
144.0 144.0 293.0 293.0 230.0 230.0 230.0 230.0 195.0 195.0 207.0 207.0

Corr. (dB/m)
-12.8 -12.8 -12.3 -12.3 -13.4 -13.4 -10.6 -10.6
-8.4 -8.4 -7.1 -7.2

Prüfbericht - Produkte Test Report - Products
Prüfbericht - Nr.:
Test Report No.:

CN22L8D1 001

6 Photographs of the Test Set-Up

For photographs of the test set-up, refer to the appendix A.

Seite 18 von 18 Page 18 of 18

7 List of Tables
Table 1: List of Test and Measurement Equipment..................................................................... 5 Table 2: Technical Specification of EUT ..................................................................................... 7 Table 3: Auxiliary Equipment Used during Test .......................................................................... 8



Related FCC IDs:

Search Any Device: