Sam Lin
CN22L8D1 001 FCC 15B Impacta 68i extsigned
Intelbras Industria de Telecomunicacao Eletronica Brasileira IMPACTA68I Impacta 68i 2A76R-IMPACTA68I 2A76RIMPACTA68I impacta68i
Not Your Device? Search For Manuals or Datasheets below:
File Info : application/pdf, 18 Pages, 1.22MB
Document DEVICE REPORTGetApplicationAttachment.html?id=6100419Prüfbericht - Produkte Test Report - Products Prüfbericht-Nr.: Test report no.: Kunden-Referenz-Nr.: Client reference no.: Auftraggeber: Client: Prüfgegenstand: Test item: Bezeichnung / Typ-Nr.: Identification / Type no.: Auftrags-Inhalt: Order content: Prüfgrundlage: Test specification: CN22L8D1 001 Auftrags-Nr.: Order no.: 168374470 N/A Auftragsdatum: 2022-05-26 Order date: Intelbras Industria de Telecomunicacao Eletronica Brasileira Rodovia BR 101 KM 210 Area Industrial Sao Jose Brazil Impacta exchanges Impacta 68i Test Report FCC CFR Title 47, Part 15, Subpart B Seite 1 von 18 Page 1 of 18 Wareneingangsdatum: 2022-06-27 Date of sample receipt: Prüfmuster-Nr.: Test sample no: A003285007-001 A003285010-001 A003285800-001~013 Prüfzeitraum: Testing period: 2022-07-14 2022-08-21 Please refer to Photo Document Ort der Prüfung: Place of testing: TÜV Rheinland (Shenzhen) Co., Ltd. Prüflaboratorium: Testing laboratory: TÜV Rheinland (Shenzhen) Co., Ltd. Prüfergebnis*: Test result*: Pass geprüft von: tested by: Datum: Date: 2022-08-30 Stellung / Position: Sonstiges / Other: X Signed by: Bell Hu Project Manager FCC ID: 2A76R-IMPACTA68I genehmigt von: authorized by: Ausstellungsdatum: Issue date: 2022-08-30 X Signed by: Lin Lin Stellung / Position: Reviewer Zustand des Prüfgegenstandes bei Anlieferung: Condition of the test item at delivery: Prüfmuster vollständig und unbeschädigt Test item complete and undamaged * Legende: * Legend: 1 = sehr gut 2 = gut P(ass) = entspricht o.g. Prüfgrundlage(n) 1 = very good 2 = good P(ass) = passed a.m. test specification(s) 3 = befriedigend F(ail) = entspricht nicht o.g. Prüfgrundlage(n) 3 = satisfactory F(ail) = failed a.m. test specification(s) 4 = ausreichend N/A = nicht anwendbar 4 = sufficient N/A = not applicable 5 = mangelhaft N/T = nicht getestet 5 = poor N/T = not tested Dieser Prüfbericht bezieht sich nur auf das o.g. Prüfmuster und darf ohne Genehmigung der Prüfstelle nicht auszugsweise vervielfältigt werden. Dieser Bericht berechtigt nicht zur Verwendung eines Prüfzeichens. This test report only relates to the a. m. test sample. Without permission of the test center this test report is not permitted to be duplicated in extracts. This test report does not entitle to carry any test mark. TÜV Rheinland (Shenzhen) Co., Ltd. 1601 R&D Room, 1602-1604, 17-18F, Building 7 Site C, Vanke Cloud City Phase I, Xingke First Street, Xili Street, Xili Community, Nanshan District, Shenzhen 518052, P.R. China Mail: [email protected] ·Web: www.tuv.com jjj Prüfbericht - Produkte Test Report - Products Prüfbericht - Nr.: Test Report No.: CN22L8D1 001 Test Summary 5.1.1 CONDUCTED EMISSION ON AC MAINS RESULT: Pass 5.1.2 RADIATED EMISSIONS RESULT: Pass Seite 2 von 18 Page 2 of 18 Prüfbericht - Produkte Test Report - Products Prüfbericht - Nr.: Test Report No.: CN22L8D1 001 Seite 3 von 18 Page 3 of 18 Table of Contents 1 GENERAL REMARKS ...........................................................................................................................4 1.1 COMPLEMENTARY MATERIALS ............................................................................................................4 2 TEST SITES ........................................................................................................................................5 2.1 TEST FACILITIES .................................................................................................................................5 2.2 LIST OF TEST AND MEASUREMENT INSTRUMENTS.................................................................................5 2.3 TRACEABILITY ....................................................................................................................................5 2.4 CALIBRATION .....................................................................................................................................5 2.5 MEASUREMENT UNCERTAINTY.............................................................................................................6 2.6 LOCATION OF ORIGINAL DATA.............................................................................................................6 2.7 STATUS OF FACILITY USED FOR TESTING.............................................................................................6 3 GENERAL PRODUCT INFORMATION ......................................................................................................7 3.1 PRODUCT FUNCTION AND INTENDED USE.............................................................................................7 3.2 RATINGS AND SYSTEM DETAILS ..........................................................................................................7 3.3 INDEPENDENT OPERATION MODES ......................................................................................................7 3.4 NOISE GENERATING AND NOISE SUPPRESSING PARTS .........................................................................7 3.5 SUBMITTED DOCUMENTS.....................................................................................................................7 4 TEST SET-UP AND OPERATION MODES ................................................................................................8 4.1 PRINCIPLE OF CONFIGURATION SELECTION .........................................................................................8 4.2 TEST OPERATION AND TEST SOFTWARE ..............................................................................................8 4.3 SPECIAL ACCESSORIES AND AUXILIARY EQUIPMENT ............................................................................8 4.4 COUNTERMEASURES TO ACHIEVE EMC COMPLIANCE ..........................................................................8 4.5 TEST SETUP DIAGRAM ........................................................................................................................9 5 TEST RESULTS .................................................................................................................................10 5.1.1 Conducted Emission on AC Mains.............................................................................................10 5.1.2 Radiated Emissions....................................................................................................................13 6 PHOTOGRAPHS OF THE TEST SET-UP ................................................................................................18 7 LIST OF TABLES................................................................................................................................18 Prüfbericht - Produkte Test Report - Products Prüfbericht - Nr.: Test Report No.: CN22L8D1 001 1 General Remarks Seite 4 von 18 Page 4 of 18 1.1 Complementary Materials All attachments are integral parts of this test report. This applies especially to the following appendix: Appendix A: Photographs of the Test Set-up Prüfbericht - Produkte Test Report - Products Prüfbericht - Nr.: Test Report No.: 2 Test Sites CN22L8D1 001 Seite 5 von 18 Page 5 of 18 2.1 Test Facilities TÜV Rheinland (Shenzhen) Co., Ltd. 362 Huanguan Road Middle Longhua District, Shenzhen 518110 People's Republic of China FCC Accreditation Designation No.: CN1260 2.2 List of Test and Measurement Instruments Table 1: List of Test and Measurement Equipment Conducted Emission Equipment Manufacturer EMI Test Receiver R&S Artificial Mains Network Artificial Mains Network R&S R&S EMC32 test software R&S Radiated Emission (3m chamber) Equipment Manufacturer 3m SAC ETS-Lindgren EMI Test Receiver R&S Horn Antenna R&S Preamplifier (1-18GHz) Trilog-Broadband antenna FIT SCHWARZBECK EMC32 test software R&S Model No. ESR3 ENV216 ENV432 EMC32(Ver.10.50.00) Model No. SAC3 ESR7 HF907 SCU-18F VULB9168 EMC32(Ver.10.50.00) Serial No. 102680 101445 101546 N/A Serial No. CT001632-Q1362 102111 102706 180077 0945 N/A Cal. Until 2023-02-27 2023-02-27 2023-02-27 N/A Cal. Until 2024-04-26 2022-12-01 2022-08-07 2022-08-13 2022-12-12 N/A 2.3 Traceability All measurement equipment calibrations are traceable to NIM (National Institute of Metrology) or where calibration is performed in other countries, to equivalent nationally recognized standards organizations. 2.4 Calibration Equipment requiring calibration is calibrated periodically by the manufacturer or according to manufacturer's specifications. Additionally all equipment is verified for proper performance on a regular basics using in house standards or comparisons. Prüfbericht - Produkte Test Report - Products Prüfbericht - Nr.: Test Report No.: CN22L8D1 001 Seite 6 von 18 Page 6 of 18 2.5 Measurement Uncertainty The estimated combined standard uncertainty for radiated emissions and conducted emissions measurements as below table. Parameter Radiated Emission (3m SAC), 30MHz to 1000MHz Radiated Emission (3m SAC), above 1000MHz Conducted Emission, (9kHz to 150kHz)/(150kHz to 30MHz) Uncertainty ± 4.52 dB ± 4.37 dB ± 3.70 dB / ± 3.30 dB 2.6 Location of Original Data The original copies of all test data taken during actual testing were attached at Appendix A of this report and delivered to the applicant. A copy has been retained in the TÜV Rheinland (Shenzhen) Co., Ltd. file for certification follow-up purposes. 2.7 Status of Facility Used for Testing The TÜV Rheinland (Shenzhen) Co., Ltd. Test facility located at 362 Huanguan Road Middle Longhua District, Shenzhen 518110 People's Republic of China is listed on the US Federal Communications Commission list of facilities approved to perform measurements. Prüfbericht - Produkte Test Report - Products Prüfbericht - Nr.: Test Report No.: CN22L8D1 001 3 General Product Information 3.1 Product Function and Intended Use The EUT is an Impacta exchanges. For details refer to the User Manual, Technical Description and Circuit Diagram. 3.2 Ratings and System Details Table 2: Technical Specification of EUT General Information of EUT Kind of Equipment: Type Designation: FCC ID: Operating Voltage: Operating Temperature Range: Equipement Class: Value Impacta exchanges Impacta 68i 2A76R-IMPACTA68I AC 120V, 60Hz 0 °C ~ +45 °C Class A digital device (JAD) Seite 7 von 18 Page 7 of 18 3.3 Independent Operation Modes The basic operation modes are: A. On, Normal working B. Off 3.4 Noise Generating and Noise Suppressing Parts Refer to Circuit Diagram for further details. 3.5 Submitted Documents - User Manual - ID Label and Location Info - Schematics - Operation Description - Block Diagram - PCB Layout Prüfbericht - Produkte Test Report - Products Prüfbericht - Nr.: Test Report No.: CN22L8D1 001 4 Test Set-up and Operation Modes Seite 8 von 18 Page 8 of 18 4.1 Principle of Configuration Selection Emission: The equipment under test (EUT) was configured to measure its highest possible radiation level. The test modes were adapted accordingly in reference to the instructions for use. 4.2 Test Operation and Test Software Test operation refers to test setup in chapter 5. All tests were performed according to the procedures in ANSI C63.4: 2014. According to clause 3.1, all tests were performed on model Impacta 68i in this report. 4.3 Special Accessories and Auxiliary Equipment Table 3: Auxiliary Equipment Used during Test Description Manufacturer Model Smart terminal Intelbras TI5000 S/N Remark N/A Connecting with Impacta 68i 4.4 Countermeasures to Achieve EMC Compliance The test sample which has been tested contained the noise suppression parts as described in the Technical Construction File (TCF). No additional measures were employed to achieve compliance. Prüfbericht - Produkte Test Report - Products Prüfbericht - Nr.: Test Report No.: CN22L8D1 001 4.5 Test Setup Diagram Diagram of Measurement Configuration for Radiation Test (Below 1GHz) Seite 9 von 18 Page 9 of 18 Diagram of Measurement Configuration for Radiation Test (Above 1GHz) Diagram of Measurement Configuration for Mains Conduction Measurement Prüfbericht - Produkte Test Report - Products Prüfbericht - Nr.: Test Report No.: CN22L8D1 001 5 Test Results 5.1.1 Conducted Emission on AC Mains RESULT: Test Specification Test standard Basic standard Frequency range Classification Limits Kind of test site : FCC Part 15.107(a) : ANSI C63.4:2014 : 0.15 30MHz : Class A : FCC Part 15.107(a) : Shielded Room Test Setup Date of testing Input voltage Operation mode Ambient temperature Relative humidity Atmospheric pressure : 2022-07-14 : AC 120V, 60Hz : A : 24.1 : 52.8 % : 101 kPa For the measurement records, refer to the following plots. Seite 10 von 18 Page 10 of 18 Pass Prüfbericht - Produkte Test Report - Products Prüfbericht - Nr.: Test Report No.: CN22L8D1 001 EUT Information EUT Name: Order No: Model: Test mode: Test Voltage: Test By:/Review By: Test Standard: Tem./Hum./Pressure: Remark: Impacta exchanges 168374467 Impacta 68i ON, Normal working AC 120V/50Hz Kevin Zhou/Gary Chen FCC Part 15B 24.1°C/52.8%//101kPa SR2 Seite 11 von 18 Page 11 of 18 Level in dB Critical_Freqs Frequency (MHz) MaxPeak (dBuV) 0.198000 0.198000 0.278000 --53.38 45.30 0.278000 9.002000 9.174000 13.293500 ----47.28 --- 13.557500 16.893500 16.961500 58.14 58.69 --- 24.433500 24.529500 --57.55 Average (dBuV) 39.34 ----- 27.79 36.29 --42.55 ----46.33 42.89 --- Limit (dBuV) 53.69 63.69 60.88 50.88 50.00 60.00 50.00 60.00 60.00 50.00 50.00 60.00 Margin (dB) 14.35 10.31 15.58 23.09 13.71 12.72 7.45 1.86 1.31 3.67 7.11 2.45 Line L1 L1 L1 L1 L1 L1 L1 L1 L1 L1 L1 L1 Corr. (dB) 9.9 9.9 9.9 9.9 10.3 10.3 10.4 10.4 10.4 10.4 10.4 10.4 Final_Result Frequency (MHz) QuasiPeak (dBuV) 13.293500 --- 13.557500 51.39 16.893500 52.73 16.961500 --- 24.433500 --- 24.529500 50.79 Average (dBuV) 41.25 ----- 44.29 40.69 --- Limit (dBuV) 50.00 60.00 60.00 50.00 50.00 60.00 Margin (dB) 8.75 8.61 7.27 5.71 9.31 9.21 Meas. Time (ms) 3000.0 3000.0 3000.0 3000.0 3000.0 3000.0 Bandwidth (kHz) 9.000 9.000 9.000 9.000 9.000 9.000 Line L1 L1 L1 L1 L1 L1 Corr. (dB) 10.4 10.4 10.4 10.4 10.4 10.4 Prüfbericht - Produkte Test Report - Products Prüfbericht - Nr.: Test Report No.: CN22L8D1 001 EUT Information EUT Name: Order No: Model: Test mode: Test Voltage: Test By:/Review By: Test Standard: Tem./Hum./Pressure: Remark: Impacta exchanges 168374467 Impacta 68i ON, Normal working AC 120V/50Hz Kevin Zhou/Gary Chen FCC Part 15B 24.1°C/52.8%//101kPa SR2 Seite 12 von 18 Page 12 of 18 Level in dB Critical_Freqs Frequency (MHz) MaxPeak (dBuV) 0.202000 0.206000 0.266000 --54.13 --- 0.270000 8.918000 9.042000 12.374000 47.91 --- 47.85 47.98 12.750000 16.229500 16.537500 ----52.58 25.342000 25.578000 52.09 --- Average (dBuV) 37.63 --- 29.62 --- 36.68 ----- 37.77 42.65 ----38.06 Limit (dBuV) 53.53 63.37 51.24 61.12 50.00 60.00 60.00 50.00 50.00 60.00 60.00 50.00 Margin (dB) 15.90 9.24 21.62 13.20 13.32 12.15 12.02 12.23 7.35 7.42 7.91 11.94 Line N N N N N N N N N N N N Corr. (dB) 9.8 9.8 9.8 9.8 10.0 10.0 10.1 10.1 10.2 10.2 10.3 10.3 Final_Result Frequency (MHz) QuasiPeak (dBuV) 16.229500 --- 16.537500 47.01 Average (dBuV) 42.38 --- Limit (dBuV) 50.00 60.00 Margin (dB) 7.62 12.99 Meas. Time (ms) 3000.0 3000.0 Bandwidth (kHz) 9.000 9.000 Line N N Corr. (dB) 10.2 10.2 Prüfbericht - Produkte Test Report - Products Prüfbericht - Nr.: Test Report No.: CN22L8D1 001 Seite 13 von 18 Page 13 of 18 5.1.2 Radiated Emissions RESULT: Pass Test Specification Test standard Basic standard Frequency range Classification Limits Kind of test site : FCC Part 15.109(a) : ANSI C63.4:2014 : 30MHz to 5th harmonic of the highest frequency : Class A : FCC Part 15.109(a) : 3m Semi-anechoic Chamber Test Setup Date of testing Input voltage Operation mode Ambient temperature Relative humidity Atmospheric pressure : 2022-07-26 to 2022-08-21 : AC 120V, 60Hz : A : Refer to test result : Refer to test result : 101 kPa For the measurement records, refer to the following plots. As for above 6GHz, only the noise-floors, thus no record for it. Prüfbericht - Produkte Test Report - Products Prüfbericht - Nr.: Test Report No.: CN22L8D1 001 EUT Information EUT Name: Order No: Model: Test Mode: Test Voltage: Standard: Test By:/Review By: Tem./Hum./Pressure: Remark: Impacta exchanges 168374467 30 Impacta 68i ON, Normal working AC 120V/60Hz FCC Part 15 Kevin Zhou/Gary Chen 24.1°C/55.3%/101kPa 3m chamber Seite 14 von 18 Page 14 of 18 Level in dB/m Critical_Freqs Frequency (MHz) MaxPeak Limit Margin Height Pol (dBuV/m) (dBuV/m) (dB) (cm) 94.408000 37.03 53.50 16.47 100.0 V 124.963000 36.96 53.50 16.54 100.0 V 154.548000 38.43 53.50 15.07 100.0 V 245.728000 37.52 56.00 18.48 100.0 V 368.590000 48.03 56.00 7.73 100.0 V 840.047000 42.03 56.00 13.97 100.0 V Azimuth (deg) 77.0 85.0 272.0 152.0 124.0 149.0 Corr. (dB/m) 16.2 19.1 21.4 18.6 22.9 31.3 Final_Result Frequency (MHz) QuasiPea k (dBuV/m) 368.590000 41.92 Limit (dBuV/m ) 56.00 Margin (dB) 14.08 Meas. Time (ms) Bandwid Height Pol th (cm) (kHz) 1000.0 120.000 100.0 V Azimuth Corr. (deg) (dB/m) 124.0 22.9 Prüfbericht - Produkte Test Report - Products Prüfbericht - Nr.: Test Report No.: EUT Information EUT Name: Order No: Model: Test Mode: Test Voltage: Standard: Test By:/Review By: Tem./Hum./Pressure: Remark: CN22L8D1 001 Impacta exchanges 168374467 30 Impacta 68i ON, Normal working AC 120V/60Hz FCC Part 15 Kevin Zhou/Gary Chen 24.1°C/55.3%/101kPa 3m chamber Seite 15 von 18 Page 15 of 18 Level in dB/m Critical_Freqs Frequency (MHz) MaxPeak Limit Margin Height Pol (dBuV/m) (dBuV/m) (dB) (cm) 183.939000 245.728000 40.80 44.15 53.50 56.00 12.70 11.85 200.0 H 100.0 H 368.590000 499.965000 57.60 41.39 56.00 56.00 -1.60 14.61 100.0 H 100.0 H 599.972000 840.047000 43.97 44.73 56.00 56.00 12.03 11.27 100.0 H 100.0 H Azimuth (deg) 289.0 20.0 255.0 118.0 153.0 137.0 Corr. (dB/m) 18.5 18.6 22.9 25.6 28.1 31.3 Final_Result Frequency (MHz) QuasiPea k (dBuV/m) 368.590000 51.05 Limit (dBuV/m ) 56.00 Margin (dB) 4.95 Meas. Time (ms) Bandwid Height Pol th (cm) (kHz) 1000.0 120.000 100.0 H Azimuth Corr. (deg) (dB/m) 255.0 22.9 Prüfbericht - Produkte Test Report - Products Prüfbericht - Nr.: Test Report No.: EUT Information EUT Name: Order No: Model: Test Mode: Test Voltage: Standard: Test By:/Review By: Tem./Hum./Pressure: Remark: CN22L8D1 001 Impacta exchanges 168374467 30 Impacta 68i ON, Normal working AC 120V/60Hz FCC Part 15B Kevin Zhou/Gary Chen 24.1°C/51.3%/101kPa 3m chamber Seite 16 von 18 Page 16 of 18 Level in dB/m Critical_Freqs Frequency (MHz) MaxPeak Average Limit Margin Height Pol (dBuV/m) (dBuV/m) (dBuV/m) (dB) (cm) 1080.000000 1080.000000 37.58 --- --36.84 79.50 59.50 41.92 22.66 100.0 V 100.0 V 1320.000000 1320.000000 41.57 --- --41.03 79.50 59.50 37.93 18.47 100.0 V 100.0 V 1440.000000 1440.000000 1594.500000 38.70 --- 37.10 --37.38 --- 79.50 59.50 79.50 40.81 22.12 42.40 100.0 V 100.0 V 100.0 V 1594.500000 1680.000000 1680.000000 --36.87 --- 35.06 --- 34.38 59.50 79.50 59.50 24.44 42.63 25.12 100.0 V 100.0 V 100.0 V 2312.500000 2312.500000 39.71 --- --38.68 79.50 59.50 39.79 20.82 100.0 V 100.0 V Azimuth (deg) 220.0 220.0 147.0 147.0 158.0 158.0 0.0 0.0 202.0 202.0 325.0 325.0 Corr. (dB/m) -12.8 -12.8 -13.4 -13.4 -12.6 -12.6 -10.3 -10.3 -9.5 -9.5 -6.5 -6.5 Prüfbericht - Produkte Test Report - Products Prüfbericht - Nr.: Test Report No.: EUT Information EUT Name: Order No: Model: Test Mode: Test Voltage: Standard: Test By:/Review By: Tem./Hum./Pressure: Remark: CN22L8D1 001 Impacta exchanges 168374467 30 Impacta 68i ON, Normal working AC 120V/60Hz FCC Part 15B Kevin Zhou/Gary Chen 24.1°C/51.3%/101kPa 3m chamber Seite 17 von 18 Page 17 of 18 Level in dB/m Critical_Freqs Frequency (MHz) MaxPeak Average Limit Margin Height Pol (dBuV/m) (dBuV/m) (dBuV/m) (dB) (cm) 1080.000000 1080.000000 42.04 --- --41.45 79.50 59.50 37.46 18.05 100.0 H 100.0 H 1105.500000 1106.000000 36.63 --- --35.23 79.50 59.50 42.87 24.27 100.0 H 100.0 H 1320.000000 1320.000000 1560.000000 40.57 ----- --39.80 42.93 79.50 59.50 59.50 38.93 19.70 16.57 100.0 H 100.0 H 100.0 H 1560.000000 1800.000000 1800.000000 43.83 --- 40.73 --40.33 --- 79.50 59.50 79.50 35.67 19.17 38.77 100.0 H 100.0 H 100.0 H 2040.000000 2040.500000 41.69 --- --40.86 79.50 59.50 37.81 18.64 100.0 H 100.0 H Azimuth (deg) 144.0 144.0 293.0 293.0 230.0 230.0 230.0 230.0 195.0 195.0 207.0 207.0 Corr. (dB/m) -12.8 -12.8 -12.3 -12.3 -13.4 -13.4 -10.6 -10.6 -8.4 -8.4 -7.1 -7.2 Prüfbericht - Produkte Test Report - Products Prüfbericht - Nr.: Test Report No.: CN22L8D1 001 6 Photographs of the Test Set-Up For photographs of the test set-up, refer to the appendix A. Seite 18 von 18 Page 18 of 18 7 List of Tables Table 1: List of Test and Measurement Equipment..................................................................... 5 Table 2: Technical Specification of EUT ..................................................................................... 7 Table 3: Auxiliary Equipment Used during Test .......................................................................... 8
Related FCC IDs:
- 2A76R-IMPACTA68I - Intelbras Industria de Telecomunicacao Eletronica Brasileira Impacta 68i [-IMPACTA68I] Microsoft Word 2016; modified using iText 4.2.2 by 1T3XT, AuthentiDate