Thermal Imaging - Cloudinary

Both cameras can wirelessly connect via Bluetooth to compatible A

Thermal Imaging - aemc.com

Manual cursor, automatic detection, min/max/avg on adjustable area, temperature profile, and isotherm Adjustment Automatic or manual adjustment of the minimum/maximum palette Correction Emissivity, environmental temperature, distance, relative humidity Isotherm Display Color display of a temperature range adjustable by the user

PDF Viewing Options

Not Your Device? Search For Manuals or Datasheets below:


File Info : application/pdf, 8 Pages, 5.49MB

Document DEVICE REPORT950-BR IR1950-1954
Thermal Imaging
Models 1950 & 1954
· Operational in less than 10 seconds · Focus-free capability · Exceptionally long battery life · Wirelessly integrate data from other measuring instruments · Practical: voice recordings, customizable integrated emissivity
table, organize folders by site Our products are backed by over 125 years of experience in test and measurement equipment, and encompass the latest international standards for quality and safety.
(800) 343-1391 www.aemc.com

THERMAL IMAGING IR CAMERAS

Designed for use in the electrical maintenance and mechanical maintenance sectors

MODEL 1954
Thermo Resolution 120 x 160

FEATURES

Model 1954 Feature
Laser Pointer

· Focus free quality. Provides crisp, clear thermal and real images without the need for adjustments.

· Accurate temperate measurement over the full range. From -4 to 482°F (-20 to 250°C) with a stability of 80mK at 86°F (30°C).
· Audio narration can be recorded with thermograms. You can describe the circumstances of each image, providing additional text and description to be stored with each image.

MODEL 1950
Thermo Resolution 80 x 80

· Automatic non-uniformity temperature correction. Compensates for any internal drift to improve accuracy.

· Measurement data can also be stored with each thermogram Both cameras can wirelessly connect via Bluetooth to compatible AEMC® test instruments and loggers, enabling you to combine electrical and physical measurements to the imaging data.

· Offers broad range of operational capabilities. Locating the cold and hot spots in the image, measuring the temperature of a selected point in the image, displaying the temperature profile of a line in the image, displaying points at the same temperature in the image, and freezing the colors representing the temperatures.

· CAmReport® software. Included for downloading stored files from the instrument to a computer for further processing, analysis, and report generation.

· This camera is built to last. Their rugged design survives if accidentally dropped on any of its surfaces from as high as 6'.

· Exceptionally long battery life up to 13 hours (model dependent). Ensures no loss of test time during a typical work day.

ACCESSORIES/REPLACEMENT PARTS
2121.60 - Carrying Case with Foam Insert 2126.49 - Cable - USB (Type A to 5-pin Mini-B)

PRODUCTS INCLUDE

Rugged carrying case, 4 NiMH rechargeable batteries and charger, Bluetooth headset, USB cable, User
Manual, Micro SD HC card and CAmReport® software.

2 www.aemc.com

Technical Assistance (800) 343-1391

SPECIFICATIONS

MODEL 1950

MODEL 1954

IR DETECTOR

Type

UFPA microbolometer

Spectral Range Resolution

80 x 80

8 ~14m

120 x 160

IMAGING PERFORMANCE

NETD Frequency Field of View IFOV (spatial resolution) Minimal Focal Distance

<80mK @ 86°F (30°C) (0.08 @ 30°C)

9Hz

20° x 20°

28° x 38°

4.4mrad

4.1mrad

1.3 ft (0.4m), fixed focus

0.98ft (0.3m) fixed focus

FOCUSING

Adjustment

Fixed

VISUAL IMAGE

Resolution Minimal Focal Distance

240 x 320 pixels

2" (5cm)

480 x 640 pixels

PRESENTATION OF IMAGES

Images Displayed LCD Screen Image Display

Infrared image and real image with automatic parallax compensation 2.8" (7.1cm)
Multiple palettes selectable

FUNCTIONS

Image Freezing Storage

Animated or fixed image 2GB Micro SD card

MEASUREMENT

Temperature Range

-4°F to 482°F (-20°C to 250°C)

Accuracy

±2°C or ±2% of reading

ANALYSIS FUNCTIONS
Analysis Tools
Adjustment Correction Isotherm Display Voice Recording ENVIRONMENTAL SPECIFICATIONS

Manual cursor, automatic detection, min/max/avg on adjustable area, temperature profile, and isotherm
Automatic or manual adjustment of the minimum/maximum palette
Emissivity, environmental temperature, distance, relative humidity
Color display of a temperature range adjustable by the user Yes, via Bluetooth (headset supplied)

Operating Temperature Storage Temperature Humidity Drop Resistance Impact Resistance Vibration Resistance Protection

-4° to 122°F (-15° to 50°C) -40° to 158°F (-40° to 70°C)
10% to 95% 6' (2m) on all sides
25G 2G IP54

GENERAL SPECIFICATIONS

Start Up Safety
Power Supply
Laser Laser Output Laser Wavelength CAmReport® Software

Less than 3 seconds

Less than 10 seconds

EN 61326-1: 2006, EN 61010-1 Ed.2

4 x AA (1.5V) Alkaline or NiMH rechargeable batteries with charger included

Ni-MH, low discharge, 1.2V, 2500mAh

-

Class 2

-

< 1mW

-

645-655nm

Automatic report generation in .pdf or .docx (Word) format

Battery Life

13.30 hrs typical (11 hours minimum)

9 hrs typical (7 hours minimum)

Dimensions/Weight Bluetooth Product Communication

8.86 x 4.92 x 3.27" (225 x 125 x 83mm) / 25oz (700g) with rechargeable batteries

407, 607 clamps and MTX3293 dmm

407, 607 clamps, MTX3293 dmm environmental models 1110, 1227, 1246, 1821, 1822, 1823

Technical Assistance (800) 343-1391

www.aemc.com 3

CAMERA CONSTRUCTION

Performs infrared thermography, an indispensable means for ensuring safety
Left Side of Camera:
PROTECTIVE ELASTOMER FLAP MINI USB CONNECTOR MICRO SD SLOT
MULTIPLE-FUNCTION KEYS ASSOCIATED WITH THE DISPLAY
NAVIGATION KEYS

PROTECTIVE LENS COVER Protects against scratches
LASER POINTER THERMAL LENS
VISIBLE CAMERA LENS

Model 1954 includes laser

CONFIGURABLE TRIGGER Offers exceptional ergonomics
Balance guaranteed: the camera stands on its own!

AUTOMATIC BRIGHTNESS SENSOR
ON/OFF KEY

4 www.aemc.com

Technical Assistance (800) 343-1391

DISPLAY & MENU CONTENTS

Programmable cursors provide a comprehensive set of options for evaluating thermal profiles

SELECTABLE CURSOR TOOLS
NONE
No cursor display, temperature evaluation is determined by color palette only.
MIN/MAX
Automatically displays the cold and hot spot values at the Min and Max cursor positions.
POINT
Displays the value at the cursor. Cursor is movable using the navigation keys.

ISOTHERM
Displays points that fall in the same temperature range in the same color. User picks green, red or brown as the display color and defines the range and tolerance.
PROFILE
Displays the temperature profile of a line defined by the cursor. Cursor can be moved along the line to get an individual temperature.
SQUARE
Displays the Min/Max and mean values within the box. Box size and location is user adjustable.

EASY ACCESS MENUS

MAIN MENU DISPLAY DIRECTORY MENU

MAIN TARGET MENU VOCAL RECORD MENU

Technical Assistance (800) 343-1391

www.aemc.com 5

CAmReport® SOFTWARE

Comprehensive software offering all the necessary functions for effective analysis of measurement results and report generation

Create reports using one of three available templates. Export reports to Word or PDF format making them easy to print and/or archive

FEATURES
· Transfer measurements from camera to software via USB cable, wireless Bluetooth, or removable SD card
· Drag-and-drop measurement images right from the storage directory to the analysis window
· Includes thermal and real images automatically
· Superimpose thermal images over real images for better visual analytical results
· Locate Min/Max and mean temperatures of the image or an area of the image
· User selectable color palette from seven different types
· Summary table automatically displays environmental parameters and statistical results of the measurements
· Include dictated audio comments in the report
· Includes multiple analytical tools for assessing thermal images
· Manually enter measurement analysis findings, site characteristics and operator information to your report
· Add graphics such as logos to your reports
· Correct measurement results using built-in or user configured emissivity tables
· Include multiple measurements in any report
· Save reports as a Word or PDF document

Typical analysis tab screen

CATALOG NO.
2121.40 2121.41
6 www.aemc.com

DESCRIPTION
Thermal Imaging IR Camera Model 1950 Thermal Imaging IR Camera Model 1954

Technical Assistance (800) 343-1391

BLUETOOTH CAPABILITY

Wirelessly connects via Bluetooth to compatible clamp-on meters, multimeters and environmental loggers combining electrical and physical
measurements to imaging data for a complete analysis capability

In addition to capturing both real and thermal images, these cameras are capable of Bluetooth communication with a variety of instruments to give you the full measurement picture.
MODEL 407, MODEL 607, MTX3293
The Model 1950 and 1954 can receive data from the Models 407 and 607 power clamp meters and the MTX3293 multimeter providing the ability to store electrical real time measurements with the thermogram.
ENVIRONMENTAL DATA LOGGERS
The Model 1954 also communicates with AEMC's environmental data loggers to include the ability to add humidity, dew point, wind speed and flow, as well as light measurements to thermograms.

INSTRUMENT COMPATIBILITY 407 Power Clamp meter 607 Power Clamp meter MTX3293-BT Multimeter 1110 Lightmeter Data Logger 1227 Thermo-Anemometer Data Logger 1246 Thermo-Hygrometer Data Logger 1821 Thermocouple Thermometer Data Logger 1822 Thermocouple Thermometer Data Logger 1823 RTD Thermometer Data Logger

1950
  

1954
        

Thermogram and connectivity to the Thermo-Hygrometer Model 1246

Technical Assistance (800) 343-1391

COMPATIBLE INSTRUMENTS
(Shown, from left:)
2139.51 - Power Clamp-on Meter Model 407 2139.61 - Power Clamp-on Meter Model 607
2154.06 - MTX3293-BT Multimeter 2121.71 - Environmental Data Logger Model 1110 2121.72 - Environmental Data Logger Model 1227 2121.73 - Environmental Data Logger Model 1246 2121.74 - Environmental Data Logger Model 1821 2121.75 - Environmental Data Logger Model 1822 2121.76 - Environmental Data Logger Model 1823
www.aemc.com 7

www.aemc.com

United States & Canada
Chauvin Arnoux®, Inc. d.b.a. AEMC® Instruments 200 Foxborough Blvd. Foxborough, MA 02035 USA (508) 698-2115 · Fax (508) 698-2118
Customer Support for placing an order, obtaining price & delivery (800) 343-1391 [email protected]
Sales & Marketing Department for general sales and marketing information [email protected] [email protected]
Repair & Calibration Service for information on repair & calibration [email protected]

United States & Canada (continued)
Technical & Product Application Support for technical and application support (800) 343-1391 [email protected]
Webmaster for information regarding our website www.aemc.com [email protected]
South America, Central America, & the Caribbean
Chauvin Arnoux®, Inc. d.b.a. AEMC® Instruments 15 Faraday Drive Dover, NH 03820 USA [email protected]

Australia & New Zealand
Chauvin Arnoux®, Inc. d.b.a. AEMC® Instruments 15 Faraday Drive Dover, NH 03820 USA [email protected]
All other countries
Chauvin Arnoux® SCA 190, rue Championnet 75876 Paris Cedex 18, France Tel 33 1 44 85 45 28 Fax 33 1 46 27 73 89 [email protected] www.chauvin-arnoux.com

Visit our website at www.aemc.com

Call the AEMC® Instruments Technical Assistance Hotline for immediate consultation with an applications engineer: (800) 343-1391
Chauvin Arnoux®, Inc. d.b.a AEMC® Instruments · 200 Foxborough Blvd. · Foxborough, MA 02035 USA · (800) 343-1391 · (508) 698-2115 · Fax (508) 698-2118 Export Department: (603) 740-7520 · Fax (603) 740-7550 · E-mail: [email protected]

© 2019 Chauvin Arnoux®, Inc. d.b.a. AEMC® Instruments

950-BR_IR1950-1954_0119 Printed in the USA


Adobe PDF Library 15.0 Adobe InDesign 14.0 (Windows)

Search Any Device: