Akram HAKKARI
Test Report
Markem-Imaje Industries RMCIJ1 2AAW8-RMCIJ1 2AAW8RMCIJ1 rmcij1
Not Your Device? Search For Manuals or Datasheets below:
File Info : application/pdf, 39 Pages, 3.03MB
Document DEVICE REPORTGetApplicationAttachment.html?id=7386469Template : March 5th, 2024 TEST REPORT N°: 21661458-798897-A(FILE#7392635) Accreditation N°1-1633 Scope available on www.cofrac.fr Version: 01 Subject Issued to Apparatus under test Product Trade mark Manufacturer Family range Model under test Serial number FCCID IC Conclusion Test date Test location FCC Test site ISED Test site Sample receipt date Composition of document Document issued on Written by : Akram HAKKARI Tests operator Radio spectrum tests according to the standards: FCC CFR 47 Part 15.225 & ANSI C63.10 RSS 210 & RSS-Gen MARKEM-IMAJE INDUSTRIES 9 RUE GASPARD MONGE 26500 BOURG LES VALENCE FRANCE Module RFID : RMCIJ1 MARKEM-IMAJE MARKEM-IMAJE INDUSTRIES Module RFID for CIJ printers RMCIJ1 G123291187 2AAW8-RMCIJ1 11372A-RMCIJ1 See Test Program chapter March 20, 2024 to March 22, 2024 LCIE Grenoble FR0008 - 918017 (MOI) 6500A (MOI) March 04, 2024 39 pages June 06, 2024 Approved by : Majid MOURZAGH Technical manager Reproduction of this document is only authorized in its complete form. Any partial reproduction or any insertion of results in an accompanying text with a view to their distribution must receive prior and formal agreement from LCIE. This document results from tests carried out on a specimen, sample or test piece. It does not prejudge the conformity of all the products manufactured to the object tested. Unless otherwise indicated or rule specified by the test method, the decision of conformity does not take into account measurement uncertainty. It in no way prejudges a certification decision. The accreditation of the COFRAC Testing Section attests to the technical competence of the laboratories for the tests covered by the accreditation only. If certain tests mentioned in this report were carried out outside the framework of COFRAC accreditation, they are identified by the symbol . LCIE Laboratoire Central des Industries Electriques Une société Bureau Veritas Z.I Centr'alp 170, Rue de Chatagnon 38430 Moirans FRANCE Tél. + 33 4 76 07 36 36 [email protected] www.lcie.fr SAS au capital de 15 745 984 / RCS Nanterre B 408 363 174 / N° TVA intracommunautaire FR01 408 363 174 / N°SIRET 408 363 174 00017 PUBLICATION HISTORY Version Date Author Modification 01 June 06, 2024 Akram HAKKARI Creation of the document Each new edition of this test report replaces and cancels the previous edition. The control of the old editions of report is under responsibility of client. N°21661458-798897-A(FILE#7392635) TEST REPORT Version : 01 Page 2/39 SUMMARY 1. TEST PROGRAM ............................................................................................................................. 4 2. EQUIPMENT UNDER TEST: CONFIGURATION (DECLARED BY PROVIDER) .............................. 5 3. OCCUPIED BANDWIDTH............................................................................................................... 10 4. 20DB EMISSION BANDWIDTH ...................................................................................................... 13 5. FREQUENCY TOLERANCE ........................................................................................................... 16 6. FIELD STRENGTH WITHIN THE BAND 13.110-14.010MHZ ......................................................... 19 7. FIELD STRENGTH OUTSIDE OF THE BANDS 13.110-14.010 MHZ ............................................. 24 8. MEASUREMENT OF CONDUCTED EMISSION ............................................................................ 33 9. UNCERTAINTIES CHART .............................................................................................................. 39 N°21661458-798897-A(FILE#7392635) TEST REPORT Version : 01 Page 3/39 1. TEST PROGRAM References 47 CFR Part 15.225 (2023) RSS 210 Issue 10.1 RSS Gen Issue 5.2 ANSI C63.10 (2013) Radio requirement: Clause - Test Description Test result - Comments Occupied Bandwidth ISED PASS 20dB Bandwidth FCC & ISED PASS Frequency Tolerance FCC & ISED PASS Field strength within the band [13.110-14.010] MHz FCC & ISED PASS Field strength outside of the bands [13.110-14.010] MHz FCC & ISED PASS Measurement of conducted emission FCC & ISED PASS Receiver Radiated Emissions ISED This table is a summary of test report, see conclusion of each clause of this test report for detail. (1) Limited program (2) Testing covered the receive mode, and receiver spurious emissions are considered to be the same as transmitter. PASS: EUT complies with standard's requirement FAIL: EUT does not comply with standard's requirement NA: Not Applicable NP: Test Not Performed PASS(2) N°21661458-798897-A(FILE#7392635) TEST REPORT Version : 01 Page 4/39 2. EQUIPMENT UNDER TEST: CONFIGURATION (DECLARED BY PROVIDER) 2.1. HARDWARE IDENTIFICATION (EUT AND AUXILIARIES) Equipment under test (EUT): Model under test: RMCIJ1 Serial Number: G123291187 Dimensions: Type: 15cm x 8.5cm x 1cm (Length x Width x Height) Table-Top Power supply: Name Supply1 Type USB NC: Not communicated by provider Rating 5V Reference / Sn - N°21661458-798897-A(FILE#7392635) TEST REPORT Version : 01 Comments - Page 5/39 Inputs/outputs - Cable: Access Supply1 NC: Not communicated by provider Type USB Auxiliary equipment used during test: Type Reference Laptop DELL 2 x TAG Markem-Imaje A54691 Plastic case Markem-Imaje 10110687 Interface board Markem-Imaje 10113878 USB UART Cable - NC: Not communicated by provider Length used (m) Declared <3m Shielded - - - Comments - Sn Comments - - - - - - - N°21661458-798897-A(FILE#7392635) TEST REPORT Version : 01 Page 6/39 Equipment information (declaration of provider): Type: Chipset / RF Module Frequency band: Number of Channel: Antenna Type: Transmit chains: Receiver chains Operating temperature range: Operating voltage: RFID EM Microelectronic - Marin SA, EM4094 [13.553 to 13.567] MHz 1 Internal 1 1 Tmin: -20 °C Tnom: 20°C Tmax: 60 °C Vmin (85% Vnom): 4.5 VDC Vnom: 5 VDC Vmax (115% Vnom): 5.5 VDC Antenna Dimensions 50 mm x 25 mm Hardware information Highest internal frequency (PLL, Quartz, Clock, Microprocessor...): FHighest: Firmware (if applicable): V: Software (if applicable): V: NC: Not communicated by provider 150 MHz V 1.0 NA N°21661458-798897-A(FILE#7392635) TEST REPORT Version : 01 Page 7/39 2.2. RUNNING MODE Test mode Description of test mode Test mode 1 Permanent emission with modulation on a fixed channel in the data rate that produced the highest power. Tests are performed with "TAG". Test mode 2 Permanent reception Test Running mode Occupied Bandwidth Test mode 1 20dB Emission Bandwidth Test mode 1 Frequency Tolerance Test mode 1 Field strength within the band 13.110-14.010MHz Test mode 1 Field strength outside of the bands 13.110-14.010 MHz Test mode 1 Receiver Radiated Emissions Test mode 2 (1) (1) The test can't be performed because the transmitter and receiver are operating at the same frequency and the transmitter cannot be switched off as the carrier is used as receiver injection signal 2.3. EQUIPMENT LABELLING Label 2.4. EQUIPMENT MODIFICATIONS DURING THE TESTS None N°21661458-798897-A(FILE#7392635) TEST REPORT Version : 01 Page 8/39 2.5. FIELD STRENGTH CALCULATION The field strength is calculated by adding the Antenna Factor and Cable Factor, and subtracting the Amplifier Gain (if any) from the measured reading. The basic equation with a sample calculation is as follow: = + + Where: FS = Field Strength RA = Receiver Amplitude AF = Antenna Factor CF = Cable Factor AG = Amplifier Gain Example: Assume a receiver reading of 52.5dBµV is obtained. The antenna factor of 7.4 and a cable factor of 1.1 are added. The amplifier gain of 29dB is subtracted, giving a field strength of 32 dBµV/m. FS = 52.5 + 7.4 + 1.1 29 = 32 dBµV/m The 32 dBµV/m value can be mathematically converted to its corresponding level in µV/m. Level in µV/m = Common Antilogarithm [(32dBµV/m)/20] = 39.8 µV/m. 2.6. TEST DISTANCE EXTRAPOLATION FCC/ISED The field strength is extrapolated to the new measurement distance using formula from FCC Part15.31 (f) and §6.5-6.6 RSS-GEN: Below 30MHz, Above 30MHz, Where: FSlimit is the calculation of field strength at the limit distance, expressed in dBV/m FSmax is the measured field strength, expressed in dBV/m dmeasure is the distance of the measurement point from the EUT dlimit is the reference limit distance 2.7. CALIBRATION DATE The calibration intervals are extended at 12+2 months. This extended interval is based on the fact that there is sufficient calibration data to statistically establish a trend or based on experience of use of the test equipment to assure good measurement results for a longer period. 2.8. METHOD TO DETERMINATE THE SPURIOUS RADIATED EMISSION The Normalized Site Attenuation (NSA) is added to the maximum values observed during the azimuth search in order to obtain the spurious radiated emission. For spurious above -6dB from the limit found with the NSA, the Substitution Method is applied. The substitution antenna replaces the equipment under test (EUT) for Effective Radiated Power (ERP) or Effective Isotropically Radiated Power (EIRP) measurement following the standard. Power is measured for a high level and calculated for the same level of radiated field strength obtained on the measuring antenna and EUT. N°21661458-798897-A(FILE#7392635) TEST REPORT Version : 01 Page 9/39 3. OCCUPIED BANDWIDTH 3.1. TEST CONDITIONS Date of test Test performed by Relative humidity (%) Ambient temperature (°C) : March 21, 2024 : Akram HAKKARI : 33 : 20 3.2. TEST SETUP The Equipment Under Test is installed in a climatic chamber. Measurement is performed with a spectrum analyzer in radiated method. The EUT is turned ON, the center frequency of the spectrum analyzer is set to the fundamental frequency. The captured power is measured and recorded; the measurement is repeated until all frequencies required were complete. Test Procedure: RSS-Gen Issue 5 § 6.7 o RBW used in the range of 1% to 5% of the anticipated emission bandwidth o Set the video bandwidth (VBW) 3 x RBW. o Detector = Peak. o Trace mode = Max Hold. o Sweep = Auto couple. o Allow the trace to stabilize. o OBW 99% function of spectrum analyzer used or EUT Spectrum analyser Or EMI receiver Test setup of Occupied Bandwidth N°21661458-798897-A(FILE#7392635) TEST REPORT Version : 01 Page 10/39 3.3. LIMIT None 3.4. TEST EQUIPMENT LIST Description AC source 1kW Antenna Loop (near field) Attenuator 10dB Cable SMA 2m Climatic chamber Data Logger (CEM1) Spectrum Analyzer 9kHz - 6GHz Thermo-hygrometer Photo of Occupied bandwidth TEST EQUIPMENT USED Manufacturer Model KEYSIGHT AC6802A ELECTRO-METRICS EM-6993 AEROFLEX _ _ 6GHz BIA CLIMATIC CL 6-25 AGILENT 34970A ROHDE & SCHWARZ FSL6 TESTO 608-H1 Identifier A7042305 C2040215 A7122267 A5329635 D1022117 A6440083 A2642020 B4204120 Cal_Date 09/22 10/23 03/22 01/23 05/23 10/22 03/23 Cal_Due 09/25 10/25 03/24 01/25 05/25 10/24 03/25 N°21661458-798897-A(FILE#7392635) TEST REPORT Version : 01 Page 11/39 3.5. DIVERGENCE, ADDITION OR SUPPRESSION ON THE TEST SPECIFICATION None 3.6. RESULTS Occupied Bandwidth 13.56MHz Offs -35.00 dB Att 20 dB Ref 72.00 dBµV 1Pk View 60 dBµV 50 dBµV * RBW 3 kHz * VBW 10 kHz SWT 50ms M1[1] Occ Bw T1[1] T2[1] M1 40 dBµV 30 dBµVT1 20 dBµV 10 dBµV 0 dBµV -10 dBµV -20 dBµV 47.22 dBµV 13.559982000 MHz 14.308000000 kHz 23.88 dBµV 13.552348000 MHz 23.05 dBµV 13.566656000 MHz T2 CF 13.559905 MHz Date: 22.MAR.2024 09:15:00 Span 20.0 kHz Frequency (MHz) 13.56MHz Occupied Bandwidth (KHz) 14.3 3.7. CONCLUSION Occupied Channel Bandwidth measurement performed on the sample of the product RMCIJ1, Sn: G123291187, in configuration and description presented in this test report, show levels compliant to the RSS-GEN limits. N°21661458-798897-A(FILE#7392635) TEST REPORT Version : 01 Page 12/39 4. 20DB EMISSION BANDWIDTH 4.1. TEST CONDITIONS Date of test Test performed by Relative humidity (%) Ambient temperature (°C) : March 21, 2024 : Akram HAKKARI : 33 : 20 4.2. TEST SETUP The Equipment Under Test is installed in a climatic chamber. Measurement is performed with a spectrum analyzer in radiated method. Test Procedure: ANSI C63.10 § 6.9.2: The EUT is turn ON; levels have been corrected to be in compliant with the Peak Output Power measured; and using the MaxHold function, the frequency separation of two frequencies that were attenuated 20dB from the Peak Output Power level. A delta marker is used to measure the frequency difference as the emission bandwidth. or EUT Spectrum analyser Or EMI receiver Test setup of 20dB emission bandwidth N°21661458-798897-A(FILE#7392635) TEST REPORT Version : 01 Page 13/39 Photo of 20dB emission bandwidth 4.3. LIMIT No Limit 4.4. TEST EQUIPMENT LIST Description AC source 1kW Antenna Loop (near field) Attenuator 10dB Cable SMA 2m Climatic chamber Data Logger (CEM1) Spectrum Analyzer 9kHz - 6GHz Thermo-hygrometer TEST EQUIPMENT USED Manufacturer Model KEYSIGHT AC6802A ELECTRO-METRICS EM-6993 AEROFLEX _ _ 6GHz BIA CLIMATIC CL 6-25 AGILENT 34970A ROHDE & SCHWARZ FSL6 TESTO 608-H1 Identifier A7042305 C2040215 A7122267 A5329635 D1022117 A6440083 A2642020 B4204120 4.5. DIVERGENCE, ADDITION OR SUPPRESSION ON THE TEST SPECIFICATION None Cal_Date 09/22 10/23 03/22 01/23 05/23 10/22 03/23 Cal_Due 09/25 10/25 03/24 01/25 05/25 10/24 03/25 N°21661458-798897-A(FILE#7392635) TEST REPORT Version : 01 Page 14/39 4.6. RESULTS Frequency (MHz) 13.56 Graph 20 dB Bandwidth (kHz) 2.61 Offs -35.00 dB Att 10 dB Ref 57.88 dBµV 1Pk 50 dBµV View 40 dBµV 30 dBµV 20 dBµV * RBW 1 kHz * VBW 3 kHz SWT 150ms M1[1] ndB M1 Bw Q factor T1[1] T1 T2[1] 47.54 dBµV 13.559963000 MHz 20.00 dB 2.612670000 kHz 5190.1 27.53 dBµV 13.558660330 MHz 27.52 dBµV 13.561273000 MHz 10 dBµV 0 dBµV -10 dBµV -20 dBµV -30 dBµV -40 dBµV CF 13.56 MHz Date: 22.MAR.2024 09:52:02 Span 20.0 kHz 4.7. CONCLUSION 20dB Emission Bandwidth measurement performed on the sample of the product RMCIJ1, Sn: G123291187, in configuration and description presented in this test report, show levels compliant to the 47 CFR PART 15.225 & RSS 210 limits. N°21661458-798897-A(FILE#7392635) TEST REPORT Version : 01 Page 15/39 5. FREQUENCY TOLERANCE 5.1. TEST CONDITIONS Date of test Test performed by Relative humidity (%) Ambient temperature (°C) : March 22, 2024 : Akram HAKKARI : 32 : 21 5.2. TEST SETUP The Equipment Under Test is installed in a climatic chamber. Measurement is performed with a spectrum analyzer in radiated method. Test Procedure: ANSI C63.10 § 6.8 or EUT Spectrum analyser Or EMI receiver Test setup of frequency tolerance N°21661458-798897-A(FILE#7392635) TEST REPORT Version : 01 Page 16/39 Photo of frequency tolerance 5.3. LIMIT ±0.01% (± 100ppm) 5.4. TEST EQUIPMENT LIST Description AC source 1kW Antenna Loop (near field) Attenuator 10dB Cable SMA 2m Climatic chamber Data Logger (CEM1) Spectrum Analyzer 9kHz - 6GHz Thermo-hygrometer TEST EQUIPMENT USED Manufacturer Model KEYSIGHT AC6802A ELECTRO-METRICS EM-6993 AEROFLEX _ _ 6GHz BIA CLIMATIC CL 6-25 AGILENT 34970A ROHDE & SCHWARZ FSL6 TESTO 608-H1 Identifier A7042305 C2040215 A7122267 A5329635 D1022117 A6440083 A2642020 B4204120 5.5. DIVERGENCE, ADDITION OR SUPPRESSION ON THE TEST SPECIFICATION None Cal_Date 09/22 10/23 03/22 01/23 05/23 10/22 03/23 Cal_Due 09/25 10/25 03/24 01/25 05/25 10/24 03/25 N°21661458-798897-A(FILE#7392635) TEST REPORT Version : 01 Page 17/39 5.6. RESULTS EUT activation: Startup Voltage: Temperature: Frequency (MHz) Frequency Drift (%) EUT activation: -20°C 13.559941 -0.0004% -10°C 13.559970 -0.0002% 0°C 13.559749 -0.0018% 10°C 13.559978 -0.0002% Vnom 20°C 13.559957 -0.0003% 2min 30°C 40°C 50°C 60°C 13.559930 13.55991907 13.55989707 13.55989679 -0.0005% -0.0006% -0.0008% -0.0008% Voltage: Temperature: Frequency (MHz) Frequency Drift (%) EUT activation: Vnom -20°C -10°C 0°C 10°C 20°C 30°C 13.5599615 13.5599524 13.5599875 13.5597734 13.5599725 13.5599303 -0.0003% -0.0004% -0.0001% -0.0017% -0.0002% 5min -0.0005% 40°C 13.5599155 -0.0006% 50°C 13.5599081 -0.0007% 60°C 13.5599 -0.0008% Voltage: Vnom Temperature: -20°C -10°C 0°C 10°C 20°C 30°C 40°C 50°C 60°C Frequency (MHz) Frequency Drift (%) EUT activation: 13.5599416 -0.0004% 13.5600893 0.0007% 13.5599893 -0.0001% 13.5599782 -0.0002% 13.5598319 -0.0012% 10min 13.5599302 -0.0005% 13.55992 -0.0006% 13.5598786 -0.0009% 13.5599 -0.0008% Voltage: Temperature: Frequency (MHz) Frequency Drift (%) Vnom -20°C -10°C 0°C 10°C 20°C 30°C 40°C 13.5598678 13.559857 13.5599893 13.5600134 13.5597636 13.5599303 13.5599163 -0.0010% -0.0011% -0.0001% 0.0001% -0.0017% -0.0005% -0.0006% 50°C 13.5598934 -0.0008% 60°C 13.5599 -0.0008% Temperature Voltage: Frequency (MHz) Frequency Drift (%) Vmin 13.55974536 -0.0018% Tnom Vnom 13.55975461 -0.0018% Vmax 13.55979675 -0.0018% 5.7. CONCLUSION Frequency tolerance measurement performed on the sample of the product RMCIJ1, Sn: G123291187, in configuration and description presented in this test report, show levels compliant to the 47 CFR PART 15.225 & RSS 210 limits. N°21661458-798897-A(FILE#7392635) TEST REPORT Version : 01 Page 18/39 6. FIELD STRENGTH WITHIN THE BAND 13.110-14.010MHZ 6.1. TEST CONDITIONS Date of test Test performed by Relative humidity (%) Ambient temperature (°C) : March 22, 2024 : Akram HAKKARI : 32 : 22 6.2. TEST SETUP The Equipment Under Test is installed on an Open Area Test Site.. Measurement is performed with a spectrum analyzer in radiated method. Test Procedure: ANSI C63.10 The EUT is placed on an open area test site. Distance between measuring antenna and the EUT is 10m. Test is performed in parallel, perpendicular, and ground parallel axis with a loop antenna below 30MHz. Measurement bandwidth was 9kHz between 150kHz & 30MHz. The level has been maximized by the turntable rotation of 360 degrees range on all axis of EUT used in normal configuration. Antenna height search was performed from 1 to 4m. The EUT is place at 0.8m. Ambient temperature: 26 °C Relative humidity: 35 % Note: It is impracticable to carry out tests under normal condition as specified in standard. When measurement with test fixture is used, the power level calibration of the spectrum analyzer shall then be related to the power level or field strength measured with temperature during OATS measure taking in consideration in climatic chamber. The calculation will be used to calculate the absolute level of the sideband power. Frequency band 13.110-14.010MHz Following plots show radiated emission level in the frequency band 13.110-14.010MHz with a RBW of 9kHz and a quasipeak detector. The graphs are obtained with a measuring receiver. N°21661458-798897-A(FILE#7392635) TEST REPORT Version : 01 Page 19/39 EUT Spectrum analyser Or EMI receiver Test setup of Field strength within the band 13.110-14.010MHz in OATS Photo of Field strength within the band 13.110-14.010MHz in OATS N°21661458-798897-A(FILE#7392635) TEST REPORT Version : 01 Page 20/39 or EUT Spectrum analyser Or EMI receiver Test setup of Field strength within the band 13.110-14.010MHz in Climatic Chamber Photo of Field strength within the band 13.110-14.010MHz in Climatic Chamber 6.3. LIMIT Frequency (MHz) 13.553-13.567 13.410-13.553 13.567-13.710 13.110-13.410 13.710-14.010 Below 13.110MHz Above 14.010MHz Field strength (µV/m) @30m 15 848 334.0 106.0 30.0 Field strength (dBµV/m) @30m 84.0 50.5 40.5 29.5 N°21661458-798897-A(FILE#7392635) TEST REPORT Version : 01 Page 21/39 6.4. TEST EQUIPMENT LIST Description AC source 1kW Antenna Loop (near field) Attenuator 10dB Cable SMA 2m Climatic chamber Spectrum Analyzer 9kHz - 6GHz Thermo-hygrometer Antenna Mat (OATS) Cable Cable (OATS) Cable substitution (OATS) Cable substitution (OATS) Emission Cable OATS RADIO ERP_EIRP Rehausse Table C1/OATS Table C1/OATS Thermo-hygrometer (PM1/2/3) Turntable (OATS) Turntable / Mast controller (OATS) Antenna loop Receiver 20Hz 8GHz TEST EQUIPMENT USED Manufacturer Model KEYSIGHT AC6802A ELECTRO-METRICS EM-6993 AEROFLEX _ _ 6GHz BIA CLIMATIC CL 6-25 ROHDE & SCHWARZ FSL6 TESTO 608-H1 ETS Lingren 2071-2 RADIALEX _ _ 1GHz RADIALEX RADIALEX RADIALEX _ _ LCIE SUD EST RADIO ERP_EIRP v4 LCIE _ LCIE _ KIMO HQ 210 ETS Lingren Model 2187 ETS Lingren Model 2066 ELECTRO-METRICS EM-6879 ROHDE & SCHWARZ ESU8 Identifier A7042305 C2040215 A7122267 A5329635 D1022117 A2642020 B4204120 F2000392 A5329062 A5329623 A5329059 A5329057 A5329061 F2000409 L2000034 F2000512 F2000445 B4206022 F2000403 F2000372 C2040294 A2642019 Cal_Date 09/22 10/23 03/22 01/23 10/22 03/23 08/22 09/23 09/22 09/22 07/23 08/23 05/23 08/22 03/23 Cal_Due 09/25 10/25 03/24 01/25 10/24 03/25 08/24 09/24 09/24 09/24 07/24 08/24 05/25 08/24 03/25 6.5. DIVERGENCE, ADDITION OR SUPPRESSION ON THE TEST SPECIFICATION None N°21661458-798897-A(FILE#7392635) TEST REPORT Version : 01 Page 22/39 6.6. RESULTS 6.6.1. Results on OATS test conditions: Frequency (MHz) QPeak Limit (dBµV/m) @ 30m QPeak (dBµV/m) @ 30m 13.56 84.0 47 Margin (Mes-Lim) (dB) 37 Angle Table (deg) 0 Pol Ant. 90 Ht Ant. (cm) 150 Correc. Factor (dB) 36.3 Comments - Parallel Axis (0°) Perpendicular Axis (90°) Ground Parallel Axis (180°) Note: Measure have been done at 10m distance and corrected according to requirements of 15.209.e) (M@30m = [email protected]) 6.6.2. Results under Normal condition Plots (Tnom) Offs -35.00 dB * RBW 10 kHz * Att 20 dB * VBW 30 kHz M1[1] Ref 75.00 dBµV * SWT 100s * Limit Check 70 dBµV 1QP Line BE_Fcc PASS PASS View 60 dBµV 43.68 dBµV 13.560405000 MHz 50 dBµV M1 40 dBµV 30 dBµV BE_Fcc 20 dBµV 10 dBµV 0 dBµV -10 dBµV 6.7. -20 dBµV CF 13.56 MHz Date: 22.MAR.2024 09:21:12 CONCLUSION Span 900.0 kHz Field strength within the band 13.110-14.010MHz measurement performed on the sample of the product RMCIJ1, Sn: G123291187, in configuration and description presented in this test report, show levels compliant to the 47 CFR PART 15.225 & RSS 210 limits. N°21661458-798897-A(FILE#7392635) TEST REPORT Version : 01 Page 23/39 7. FIELD STRENGTH OUTSIDE OF THE BANDS 13.110-14.010 MHZ 7.1. TEST CONDITIONS Date of test Test performed by Relative humidity (%) Ambient temperature (°C) : March 22, 2024 : Akram HAKKARI : 32 : 21 7.2. TEST SETUP Test procedure: ANSI C63.10 & FCC Part 15 subpart C Following frequency ranges, test setup parameters are different and specified in this table: Frequency range: Test: Antenna Polarization: Antenna Height: Antenna Type: RBW Filter: Maximization: EUT height: Test site: Distance EUT - Antenna: Detector: 9kHz to 30MHz Pre-Characterization Qualification Parallel, Perpendicular and Ground parallel Centered on EUT (§6.6.5 ANSI C63-10) 1m Loop 200Hz below 150kHz / 9kHz above 150kHz Turntable rotation of 360 degrees range 1.5m 1.5m Full Anechoic Chamber Open Aera Test Site 3m 10m Peak QPeak Frequency range: Test: Antenna Polarization: Antenna Height: Antenna Type: RBW Filter: Maximization: EUT height: Test site: Distance EUT - Antenna: Detector: 30MHz to 1GHz Pre-Characterization Qualification Horizontal and Vertical Centered on EUT (§6.6.5 ANSI C63-10) Varied from 1m to 4m Bi-Log 120kHz Turntable rotation of 360 degrees range 1.5m 1.5m Full Anechoic Chamber Open Aera Test Site 3m 10m Peak QPeak N°21661458-798897-A(FILE#7392635) TEST REPORT Version : 01 Page 24/39 EUT Spectrum analyser Or EMI receiver Test setup of Field strength outside the band 13.110-14.010MHz Same setup is used in semi anechoic chamber during pre-characterization, with a distance of 3m between EUT and antenna. N°21661458-798897-A(FILE#7392635) TEST REPORT Version : 01 Page 25/39 Photo of Field strength outside the band 13.110-14.010MHz N°21661458-798897-A(FILE#7392635) TEST REPORT Version : 01 Page 26/39 7.3. LIMIT Frequency range 9kHz-490kHz Frequency range 490kHz-1.705MHz 1.705MHz-30MHz Frequency range 30MHz to 88MHz 88MHz to 216MHz 216MHz to 960MHz 960MHz to 1000MHz Above 1000MHz Measure at 300m Level 67.6dBµV/m /F(kHz) Measure at 30m Level 87.6dBµV/m /F(kHz) 29.5dBµV/m Measure at 3m Level 40dBµV/m 43.5dBµV/m 46BµV/m 54dBµV/m 74dBµV/m 54dBµV/m Detector QPeak Detector QPeak QPeak Detector QPeak QPeak QPeak QPeak Peak Average 7.4. TEST EQUIPMENT LIST Description Amplifier 10MHz - 18GHz Antenna Bi-log Antenna loop BAT EMC Cable 0.75m Comb EMR HF CONTROLLER Filter Matrice Multimeter - CEM Rehausse Table C3 Semi-Anechoic chamber #3 (BF) Semi-Anechoic chamber #3 (VSWR) SMA Cable 18GHz 0.5m SMA Cable 18GHz 0.5m Spectrum analyzer Table C3 Thermo-hygrometer (PM1/2/3) TILT TEST EQUIPMENT USED Manufacturer Model LCIE SUD EST _ AH System SAS-521-7 ELECTRO-METRICS EM-6879 NEXIO v3.21.0.32 - 18GHz YORK CGE01 INNCO CO3000 LCIE SUD EST Combined filters FLUKE 87 LCIE _ SIEPEL _ SIEPEL _ TELEDYNE 18GHz TELEDYNE 18GHz ROHDE & SCHWARZ FSU 26 LCIE _ KIMO HQ 210 INNCO TILT Identifier A7102082 C2040180 C2040294 L1000115 A5329900 A3169114 D3044034 A7484078 A1240251 F2000511 D3044017_BF D3044017_VSWR A5330060 A5330059 A4060058 F2000461 B4206022 D3044033 Cal_Date 05/22 05/23 08/22 08/22 03/23 10/23 04/22 04/22 02/23 02/23 09/23 05/23 Cal_Due 05/24 05/25 08/24 08/24 03/25 10/25 04/25 04/25 02/24 02/24 09/25 05/25 N°21661458-798897-A(FILE#7392635) TEST REPORT Version : 01 Page 27/39 Turntable chamber (Cage#3) Turntable controller (Cage#3) Antenna Mat (OATS) Cable (OATS) Emission Cable Emission Cable OATS Rehausse Table C1/OATS Table C1/OATS Turntable (OATS) Turntable / Mast controller (OATS) ETS Lingren ETS Lingren ETS Lingren _ RADIALEX CABELTEL _ LCIE LCIE ETS Lingren ETS Lingren Model 2165 Model 2090 2071-2 1GHz 6GHz _ _ _ Model 2187 Model 2066 F2000371 F2000444 F2000392 A5329623 A5329061 A5329069 F2000409 F2000512 F2000445 F2000403 F2000372 7.5. DIVERGENCE, ADDITION OR SUPPRESSION ON THE TEST SPECIFICATION None 7.6. RESULTS 7.6.1. 9kHz to 1 GHz Graphs Pre characterization: Graph identifier Polarization Emr# 1 0°/90° Emr# 2 180° Emr# 3 H/V Mode TX TX TX Channel Single Single Single EUT position Axis XY/Z Axis XY/Z Axis XY/Z 09/23 07/23 02/24 08/23 09/24 07/24 02/25 08/24 Comments 9KHz-30MHz 9KHz-30MHz 30MHz-1GHz N°21661458-798897-A(FILE#7392635) TEST REPORT Version : 01 Page 28/39 Graph name: Limit: Class: Antenna polarization: Azimuth: RADIATED EMISSIONS Emr#1 Test configuration: FCC CFR47 Part15C (0°/90°) - TX mode - Automatic Axis Frequency range: [9kHz - 30MHz] RBW : 200Hz to 10kHz 0° - 360° VBW : 1kHz to 30kHz Spurious emissions Fréquence (MHz) 13.561605* 13.561605* SB Peak (dBµV/m) 2 61.94 3 61.25 *Carrier frequency No significant frequency observed Lim.Q-Peak (dBµV/m) 69.50 69.50 Angle1 (°) 86.00 63.00 Polarisation Horizontal Vertical Correction (dB) 39.01 39.01 N°21661458-798897-A(FILE#7392635) TEST REPORT Version : 01 Page 29/39 Graph name: Limit: Class: Antenna polarization: Azimuth: RADIATED EMISSIONS Emr#2 Test configuration: FCC CFR47 Part15C (180°) - TX mode - Automatic Axis Frequency range: [9kHz - 30MHz] RBW : 200Hz to 10kHz 0° - 360° VBW : 1kHz to 30kHz Spurious emissions Fréquence (MHz) 13.561605* SB Peak (dBµV/m) 2 53.93 *Carrier frequency No significant frequency observed Lim.Q-Peak (dBµV/m) 69.50 Angle1 (°) 0.00 Polarisation Horizontal Correction (dB) 39.01 N°21661458-798897-A(FILE#7392635) TEST REPORT Version : 01 Page 30/39 Graph name: Limit: Class: Antenna polarization: Azimuth: RADIATED EMISSIONS Emr#3 Test configuration: FCC CFR47 Part15C (H+V) - TX mode - Automatic Axis Frequency range: [30MHz - 1GHz] RBW : 100kHz 0° - 360° VBW : 300kHz Fréquence (MHz) 32.134 40.67 49.594 69.091 135.536 149.116 162.696 338.945 352.525 379.685 447.488 SB Peak (dBµV/m) 2 38.35 2 54.69 2 36.98 2 31.92 2 40.46 2 42.35 2 40.09 2 42.53 2 42.60 2 40.59 2 43.99 Spurious emissions Lim.Q-Peak (dBµV/m) 40.00 40.00 40.00 40.00 43.50 43.50 43.50 46.00 46.00 46.00 46.00 Angle1 (°) 67.00 167.00 347.00 60.00 356.00 319.00 331.00 301.00 85.00 110.00 52.00 Polarisation Vertical Vertical Vertical Vertical Vertical Vertical Vertical Vertical Vertical Vertical Vertical Correction (dB) 20.67 16.18 12.15 10.52 22.42 23.86 21.81 18.01 18.08 19.42 21.18 N°21661458-798897-A(FILE#7392635) TEST REPORT Version : 01 Page 31/39 Final measurement: Test Frequency (MHz) 32.1300 40.6700 49.5900 30.9700 69.0900 135.5300 149.1100 162.6900 338.9400 352.5200 379.6800 447.4880 176.2700 216.9100 474.6480 542.4500 703.1600 732.2800 759.4400 786.5000 Meter Reading dB(µV) 24.4 21.0 21.6 23.3 30.7 20.3 21.6 15.9 26.9 26.6 10.5 10.5 21.1 7.4 19.0 7.5 7.3 7.8 11.7 12.8 Detector (Pk/QP/Av) QP QP QP QP QP QP QP QP QP QP QP QP QP QP QP QP QP QP QP QP Transducer Factor (dB) 14.0 13.9 12.2 13.9 7.3 16.2 18.8 19.5 18.6 19.2 19.8 22.2 18.0 12.4 23.1 25.0 27.9 29.7 29.9 29.8 Level (dBµV/m) 38.4 34.9 33.8 37.2 38.0 36.5 40.4 35.4 45.5 45.8 30.3 32.7 39.1 19.8 42.1 32.5 35.2 37.5 41.6 42.6 Limit (dBµV/m) 40.0 40.0 40.0 40.0 40.0 43.5 43.5 43.5 46.0 46.0 46.0 46.0 43.5 46.0 46.0 46.0 46.0 46.0 46.0 46.0 Margin (dB) -1.6 -5.1 -6.2 -2.8 -2.0 -7.0 -3.1 -8.1 -0.5 -0.2 -15.7 -13.3 -4.4 -26.2 -3.9 -13.5 -10.8 -8.5 -4.4 -3.4 7.7. CONCLUSION Field strength outside of the bands 13.110-14.010 MHz measurement performed on the sample of the product RMCIJ1, Sn: G123291187, in configuration and description presented in this test report, show levels compliant to the 47 CFR PART 15.225 & RSS-Gen limits. N°21661458-798897-A(FILE#7392635) TEST REPORT Version : 01 Page 32/39 8. MEASUREMENT OF CONDUCTED EMISSION 8.1. TEST CONDITIONS Date of test Test performed by Relative humidity (%) Ambient temperature (°C) : April 12, 2024 : Akram HAKKARI : 32 : 21 8.2. TEST SETUP Test procedure: ANSI C63.10 / C63.4 & FCC Part 15 subpart C The EUT and auxiliaries are set 80cm above the ground on the non-conducting table (Table-top equipment) at 80cm from the LISN, the cable has been shorted to 1meter length. The distance between the EUT and the vertical ground plane is 40cm. Measurement is made with a receiver in peak mode. This was followed by a Quasi-Peak, i.e. CISPR measurement for any strong signal. If the average limit is met when using a Quasi-Peak detector, the EUT shall be deemed to meet both limits and measurement with the average detector is unnecessary. Interconnecting cables and equipment were moved to position that maximized emission. The EUT is powered like specified in following table, through a LISN (measure); auxiliaries are powered by another LISN. Frequency range: Test: RBW Filter: Detector: Mode: Pre-Characterization 10kHz Peak & Average 150kHz to 30MHz Linear Scan Qualification 9kHz QPeak & Cispr Average Type AC / DC (Auxiliary used) USB (Laptop auxiliary) Measurement performed: 120VAC/60Hz 240VAC/50Hz 120VAC/60Hz (Laptop auxiliary) 240VAC/50Hz (Laptop auxiliary) EUT N°21661458-798897-A(FILE#7392635) LISN Pulse Limiter Spectrum analyser Or EMI receiver TEST REPORT Version : 01 Page 33/39 Test setup of AC Power Line Conducted Emissions Photo of AC Power Line Conducted Emissions 8.3. TEST EQUIPMENT LIST Description BAT EMC Cable + self EMC comb generator LISN Receiver 20Hz 8GHz Thermo-hygrometer (PM1/2/3) Transient limiter TEST EQUIPMENT USED Manufacturer Model NEXIO v3.21.0.32 _ _ LCIE SUD EST _ ROHDE & SCHWARZ ENV216 ROHDE & SCHWARZ ESU8 KIMO HQ 210 ROHDE & SCHWARZ ESH3-Z2 Identifier L1000115 A5329578 A3169098 C2320291 A2642019 B4206022 A7122204 8.4. DIVERGENCE, ADDITION OR SUPPRESSION ON THE TEST SPECIFICATION None 8.5. TEST RESULTS RUNNING MODE N°1 Measurements are performed on the phase (L1) and neutral (N) of the power line. Results: (PEAK detection) Graph identifier Line Comments Emc# 1 Neutral 240VAC/50Hz Emc# 2 Phase 240VAC/50Hz Emc# 3 Phase 120VAC/60Hz Emc# 4 Neutral 120VAC/60Hz Cal_Date 05/22 07/23 03/23 05/23 08/22 Cal_Due 05/24 07/24 03/25 05/25 08/24 - N°21661458-798897-A(FILE#7392635) TEST REPORT Version : 01 Page 34/39 Graph name: Limit: Class: Voltage / Frequency: Line: 100 dBµV CONDUCTED EMISSIONS Emc#1 Test configuration: FCC CFR47 Part15B B Module Markem 240Vac 50Hz Neutral NEW Frequency range: [150kHz - 30MHz] RBW: 10kHz VBW: 30kHz Trace color & detector: PEAK AVG FCC/FCC CFR47 Part15B - Classe:B - Q-Peak/ FCC/FCC CFR47 Part15B - Classe:B - Avg/ 0 150kHz Fréquence Spurious emissions 30MHz Frequency (MHz) 0.154 0.342 0.71 1.064 1.54 13.56 QPeak (dBµV) 40.30 35.88 31.38 35.83 23.93 62.20 Lim.QPeak (dBµV) 65.78 59.15 56.00 56.00 56.00 60.00 QPeakLim.QPeak (dB) -25.48 -23.28 -24.62 -20.17 -32.07 2.20 CISPR.AVG Lim.CISPR.AVG CISPR.AVG- (dBµV) (dBµV) Lim.CISPR.AVG (dB) 18.23 55.78 -37.55 27.98 49.15 -21.18 9.20 46.00 -36.80 12.53 46.00 -33.47 9.37 46.00 -36.63 61.05 50.00 11.05 Correction (dB) 19.65 19.69 19.69 19.56 19.46 20.04 N°21661458-798897-A(FILE#7392635) TEST REPORT Version : 01 Page 35/39 Graph name: Limit: Class: Voltage / Frequency: Line: 80 dBµV CONDUCTED EMISSIONS Emc#2 Test configuration: FCC CFR47 Part15B B Module Markem 240Vac 50Hz Line NEW Frequency range: [150kHz - 30MHz] RBW: 10kHz VBW: 30kHz Trace color & detector: PEAK AVG FCC/FCC CFR47 Part15B - Classe:B - Q-Peak/ FCC/FCC CFR47 Part15B - Classe:B - Avg/ 0 -20 150kHz Fréquence Spurious emissions 30MHz Frequency (MHz) 0.154 0.934 1.004 1.044 1.624 13.6 QPeak (dBµV) 37.73 41.18 30.44 35.12 22.29 38.21 Lim.QPeak (dBµV) 65.78 56.00 56.00 56.00 56.00 60.00 QPeakLim.QPeak (dB) -28.05 -14.82 -25.56 -20.88 -33.71 -21.79 CISPR.AVG Lim.CISPR.AVG CISPR.AVG- (dBµV) (dBµV) Lim.CISPR.AVG (dB) 17.98 55.78 -37.81 13.72 46.00 -32.28 10.13 46.00 -35.87 22.64 46.00 -23.36 9.09 46.00 -36.91 18.49 50.00 -31.51 Correction (dB) 19.65 19.60 19.59 19.57 19.54 20.03 N°21661458-798897-A(FILE#7392635) TEST REPORT Version : 01 Page 36/39 Graph name: Limit: Class: Voltage / Frequency: Line: 80 dBµV CONDUCTED EMISSIONS Emc#3 Test configuration: FCC CFR47 Part15B A Module Markem 120Vac 60Hz Line NEW Frequency range: [150kHz - 30MHz] RBW: 10kHz VBW: 30kHz Trace color & detector: PEAK AVG FCC/FCC CFR47 Part15C - Classe:B - Q-Peak/ FCC/FCC CFR47 Part15C - Classe:B - Avg/ 0 -20 150kHz Fréquence Spurious emissions 30MHz Frequency (MHz) 0.178 0.378 0.866 1.176 4.344 13.504 QPeak (dBµV) 35.91 41.06 38.66 31.45 25.62 34.24 Lim.QPeak (dBµV) 79.00 79.00 73.00 73.00 73.00 73.00 QPeakLim.QPeak (dB) -43.09 -37.94 -34.34 -41.55 -47.38 -38.76 CISPR.AVG Lim.CISPR.AVG CISPR.AVG- (dBµV) (dBµV) Lim.CISPR.AVG (dB) 25.92 66.00 -40.08 39.42 66.00 -26.58 14.02 60.00 -45.98 11.22 60.00 -48.78 12.54 60.00 -47.46 17.68 60.00 -42.32 Correction (dB) 19.87 19.75 19.62 19.42 19.59 20.03 N°21661458-798897-A(FILE#7392635) TEST REPORT Version : 01 Page 37/39 Graph name: Limit: Class: Voltage / Frequency: Line: 100 dBµV CONDUCTED EMISSIONS Emc#4 Test configuration: FCC CFR47 Part15B B Module Markem 120Vac 60Hz Neutral NEW Frequency range: [150kHz - 30MHz] RBW: 10kHz VBW: 30kHz Trace color & detector: PEAK AVG FCC/FCC CFR47 Part15B - Classe:B - Q-Peak/ FCC/FCC CFR47 Part15B - Classe:B - Avg/ 0 150kHz Fréquence Spurious emissions 30MHz Fequency QPeak Lim.QPeak QPeak- CISPR.AVG Lim.CISPR.AVG CISPR.AVG- (MHz) (dBµV) (dBµV) Lim.QPeak (dBµV) (dBµV) Lim.CISPR.AVG (dB) (dB) 0.378 41.80 58.32 -16.52 39.70 48.32 -8.62 0.73 37.53 56.00 -18.47 12.69 46.00 -33.31 1.168 35.84 56.00 -20.16 17.48 46.00 -28.52 1.404 30.31 56.00 -25.69 10.85 46.00 -35.15 1.736 34.50 56.00 -21.50 21.88 46.00 -24.12 13.56* 60.58 60.00 0.58 59.39 50.00 9.39 * : The emission at 13.56MHz was retested and passed with 100 Ohm resistor in place of antenna Correction (dB) 19.75 19.68 19.41 19.40 19.56 20.04 8.6. CONCLUSION The sample of the equipment RMCIJ1, Sn : G123291187, tested in the configuration presented in this test report satisfies to requirements of the product family standard applied (See §Test Program) for conducted emissions. N°21661458-798897-A(FILE#7392635) TEST REPORT Version : 01 Page 38/39 9. UNCERTAINTIES CHART Kind of measurement Wide uncertainty laboratory Occupied Channel Bandwidth ±2.8 % Humidity ±3.2 % Power Spectral Density, Conducted ±1.7 dB Radio frequency ±0.3 ppm RF power, conducted ±1.2 dB RF power, radiated (Full anechoic chamber above 1GHz) ±3.7 dB RF power, radiated (Semi anechoic chamber & open test site) ±5.6 dB Spurious emission, conducted ±2.3 dB Spurious emission, radiated (Full anechoic chamber above 1GHz) ±3.8 dB Spurious emission, radiated (Semi anechoic chamber & open test site) ±5.7 dB Temperature ±0.75 °C Time ±2.3 % Voltage ±1.7 % The uncertainty values calculated by the laboratory are lower than limit uncertainty values defined by the standard. The conformity of the sample is directly established by the applicable limit values. This table includes all uncertainties maximum feasible for testing in the laboratory, whether or not made in this report. N°21661458-798897-A(FILE#7392635) TEST REPORT Version : 01 Page 39/39
Related FCC IDs:
- 2AAW8-RMCIJ1 - Markem-Imaje Industries Module RFID RMCIJ1 [-RMCIJ1] Microsoft Word pour Microsoft 365