SZ21070001W02 Anker T8010X 920MHz DXX
Morlab
Test Report DXX
Anker Innovations Limited T8010X Homebase 2 2AOKB-T8010X 2AOKBT8010X t8010x
Not Your Device? Search For Manuals or Datasheets below:
File Info : application/pdf, 26 Pages, 1.18MB
Document DEVICE REPORTGetApplicationAttachment.html?id=5411835REPORT No.SZ21070001W02 TEST REPORT APPLICANT : Anker Innovations Limited PRODUCT NAME : Homebase 2 MODEL NAME : T8010X BRAND NAME : eufy Security FCC ID : 2AOKB-T8010X STANDARD(S) : 47 CFR Part 15 Subpart C RECEIPT DATE : 2019-08-16 TEST DATE : 2019-08-29 to 2019-09-20 ISSUE DATE : 2021-08-24 Edited by: Zeng Xiaoying (Rapporteur) Approved by: Shen Junsheng (Supervisor) NOTE: This document is issued by Shenzhen Morlab Communications Technology Co., Ltd., the test report shall not be reproduced except in full without prior written permission of the company. The test results apply only to the particular sample(s) tested and to the specific tests carried out which is available on request for validation and information confirmed at our website. MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: [email protected] Page 1 of 26 REPORT No.SZ21070001W02 DIRECTORY 1. Technical Information 3 1.1. Applicant and Manufacturer Information 3 1.2. Equipment Under Test (EUT) Description 3 1.3. The Channel Number and Frequency 4 1.4. Test Standards and Results 5 1.5. Environmental Conditions 5 2. 47 CFR Part 15C Requirements 6 2.1. Antenna Requirement 6 2.2. Bandwidth 7 2.3. Conducted Emission10 2.4. Field Strength of Fundamental 14 2.5. Radiated Emission and Field Strength of Harmonics 16 Annex A Test Uncertainty 23 Annex B Testing Laboratory Information 24 Version 1.0 Change History Date 2021-08-24 Reason for change First edition MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: [email protected] Page 2 of 26 1. Technical Information REPORT No.SZ21070001W02 Note: Provide by applicant. 1.1. Applicant and Manufacturer Information Applicant: Applicant Address: Manufacturer: Manufacturer Address: Anker Innovations Limited Room 1318-19,Hollywood Plaza,610 Nathan Road, Mongkok, Kowloon, Hong Kong Anker Innovations Limited Room 1318-19,Hollywood Plaza,610 Nathan Road, Mongkok, Kowloon, Hong Kong 1.2. Equipment Under Test (EUT) Description Product Name: Sample No: Hardware Version: Software Version: Modulation Type: Operating Frequency Range: Channel Number: Antenna Type: Antenna Gain: Accessory Information: Homebase 2 11# V3 V3.0.0.3 GFSK 920.0MHz 920.8MHz 5 PCB Antenna 0dBi AC Adapter 1 Brand Name: N/A Model No.: KA2401A-1202000US Serial No.: N/A Rated Output: 12.0V 2.0A Rated Input: 100-240V 50/60Hz, 0.65A Manufacturer: Shenzhen Keyu Power Supply Technology Co., Ltd. MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: [email protected] Page 3 of 26 REPORT No.SZ21070001W02 AC Adapter 2 Brand Name: N/A Model No.: KA2401A-1202000DE Accessory Information: Serial No.: Rated Output: N/A 12.0V 2.0A Rated Input: 100-240V 50/60Hz, 0.65A Manufacturer: Shenzhen Keyu Power Supply Technology Co., Ltd. Note 1: This test report is variant from the original report (Report No.: SZ19070441W01, FCC ID: 2AOKB-T8010), based on the similarity between before, only change the model name and adaptor, the changes do not affect the results in this report. Note 2: For a more detailed description, please refer to Specification or User's Manual supplied by the applicant and/or manufacturer. 1.3. The Channel Number and Frequency Channel 1 2 3 4 5 Frequency (MHz) 920.0 920.2 920.4 920.6 920.8 MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: [email protected] Page 4 of 26 1.4. Test Standards and Results REPORT No.SZ21070001W02 The objective of the report is to perform testing according to 47 CFR Part 15 Subpart C for the EUT FCC ID Certification: No. Identity Document Title 1 47 CFR Part 15 Radio Frequency Devices Test detailed items/section required by FCC rules and results are as below: No. Section Description Test Date Test Engineer Result Method Determination /Remark 1 15.203 Antenna Requirement N/A N/A PASSNote1 No deviation 2 15.215 3 15.207 Bandwidth Conducted Emission Sep 02, 2019 Zhou Chuang PASSNote1 Aug 29, 2019 Lin Jiayong PASSNote1 No deviation No deviation 4 15.249 Field strength Radiated Sep16, 2019 Gao Jianrou PASSNote1 No deviation 5 15.209, 15.249 Emission and field strength of Sep16, 2019 Gao Jianrou PASSNote1 No deviation harmonics Note 1: The test results of these test items in this report refer to the test report (Report No.: SZ19070441W01). Note 2: The tests were performed according to the method of measurements prescribed in ANSIC63.10-2013. Note 3: Additions to, deviation, or exclusions from the method shall be judged in the "method determination" column of add, deviate or exclude from the specific method shall be explained in the "Remark" of the above table. Note 4: When the test result is a critical value, we will use the measurement uncertainty give the judgment result based on the 95% confidence intervals. 1.5. Environmental Conditions During the measurement, the environmental conditions were within the listed ranges: Temperature (°C): 15-35 Relative Humidity (%): 30-60 Atmospheric Pressure (kPa): 86-106 MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: [email protected] Page 5 of 26 REPORT No.SZ21070001W02 2. 47 CFR Part 15C Requirements 2.1. Antenna Requirement 2.1.1. Applicable Standard According to FCC 15.203, an intentional radiator shall be designed to ensure that no antenna other than that furnished by the responsible party shall be used with the device. The use of a permanently attached antenna or of an antenna that uses a unique coupling to the intentional radiator shall be considered sufficient to comply with the provisions of this section. 2.1.2. Result: Compliant The EUT has a permanently and irreplaceable attached antenna. Please refer to the EUT internal photos. MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: [email protected] Page 6 of 26 2.2. Bandwidth 2.2.1. Requirement Refer to FCC 15.215 2.2.2. Test Description Test Setup: REPORT No.SZ21070001W02 The EUT is coupled to the Spectrum Analyzer; the RF load attached to the EUT antenna terminal is 50Ohm; the path loss as the factor is calibrated to correct the reading. Make the measurement with the spectrum analyzer's resolution bandwidth (RBW) in the range of 1% to 5% of the measured bandwidth and video bandwidth (VBW) shall be approximately three times RBW. 2.2.3. Test Result A.Test Verdict: Channel Frequency (MHz) 1 920.0 3 920.4 5 920.8 20 dB Bandwidth (kHz) 102.0 102.9 101.1 Result PASS PASS PASS MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: [email protected] Page 7 of 26 B.Test Plot: REPORT No.SZ21070001W02 (Channel 1, 920.0MHz) (Channel 3, 920.4 MHz) MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: [email protected] Page 8 of 26 REPORT No.SZ21070001W02 (Channel 5, 920.8 MHz) MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: [email protected] Page 9 of 26 2.3. Conducted Emission REPORT No.SZ21070001W02 2.3.1. Requirement According to FCC section 15.207, for an intentional radiator that is designed to be connected to the public utility (AC) power line, the radio frequency voltage that is conducted back onto the AC power line on any frequency within the band 150kHz to 30MHz shall not exceed the limits in the following table, as measured using a 50µH/50 line impedance stabilization network (LISN). Frequency Range (MHz) Conducted Limit (dBµV) Quai-peak Average 0.15 - 0.50 66 to 56 56 to 46 0.50 - 5 56 46 5 - 30 60 50 Note: (a) The lower limit shall apply at the band edges. (b) The limit decreases linearly with the logarithm of the frequency in the range 0.15 - 0.50MHz. 2.3.2. Test Description Test Setup: The Table-top EUT was placed upon a non-metallic table 0.8m above the horizontal metal reference ground plane. EUT was connected to LISN and LISN was connected to reference Ground Plane. EUT was 80cm from LISN. The set-up and test methods were according to ANSI C63.10: 2013. MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: [email protected] Page 10 of 26 REPORT No.SZ21070001W02 2.3.1. Test Result The maximum conducted interference is searched using Peak (PK), if the emission levels more than the AV and QP limits, and that have narrow margins from the AV and QP limits will be re-measured with AV and QP detectors. Tests for both L phase and N phase lines of the power mains connected to the EUT are performed. Refer to recorded points and plots below. Note: Both of the test voltage AC 120V/60Hz and AC 230V/50Hz were considered and tested respectively, only the results of the worst case AC 120V/60Hz were recorded in this report. A.Test Setup: Test Mode: EUT+ ADAPTER + 920MHz TX Test voltage: AC 120V/60Hz The measurement results are obtained as below: E [dBV] =UR + LCable loss [dB] + AFactor UR: Receiver Reading AFactor: Voltage division factor of LISN MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: [email protected] Page 11 of 26 B.Test Plot: REPORT No.SZ21070001W02 (L Phase) No. Fre. (MHz) Emission Level (dBµV) Quai-peak Average 1 0.2534 53.08 36.85 2 0.3796 40.32 31.20 3 0.5824 41.58 37.31 4 1.0725 34.52 26.48 5 1.5312 34.28 29.46 6 14.5162 31.53 25.84 Limit (dBµV) Quai-peak 61.64 58.29 56.00 56.00 56.00 60.00 Average 51.64 48.29 46.00 46.00 46.00 50.00 Power-line Verdict PASS PASS Line PASS PASS PASS PASS MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: [email protected] Page 12 of 26 REPORT No.SZ21070001W02 (N Phase) No. Fre. (MHz) Emission Level (dBµV) Quai-peak Average 1 0.1726 43.08 31.52 2 0.2535 52.71 36.24 3 0.2852 34.94 28.23 4 0.4925 38.87 31.18 5 0.6264 33.45 24.97 6 13.3125 32.84 25.63 Limit (dBµV) Quai-peak 64.84 61.64 60.66 56.13 56.00 60.00 Average 54.84 51.64 50.66 46.13 46.00 50.00 Power-line Verdict Neutral PASS PASS PASS PASS PASS PASS MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: [email protected] Page 13 of 26 2.4. Field Strength of Fundamental REPORT No.SZ21070001W02 2.4.1. Requirement According to FCC section 15.249(a), except as provided in paragraph (b) of this section, the field strength of emissions from intentional radiators operated within these frequency bands shall comply with the following: Fundamental frequency Field strength of fundamental (millivolts/meter) Field strength of harmonics (microvolts/meter) 902-928 MHz 50 500 2400-2483.5 MHz 50 500 5725-5875 MHz 50 500 24.0-24.25 GHz 250 2500 2.4.2. Test Description Test Setup: The EUT is located in a 3m Semi-Anechoic Chamber; the antenna factors, cable loss and so on of the site as factors are calculated to correct the reading. For the Test Antenna: Test Antenna is 3m away from the EUT. Test Antenna height is varied from 1m to 4m above the ground to determine the maximum value of the field strength. MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: [email protected] Page 14 of 26 REPORT No.SZ21070001W02 2.4.3. Test Procedure Use the following spectrum analyzer settings: Span = wide enough to fully capture the emission being measured RBW = 120 kHz VBW RBW Sweep = auto Detector function = peak Trace = max hold 2.4.4. Test Result The measurement results are obtained as below: E [dBV/m] =UR + AT + AFactor [dB]; AT =LCable loss [dB]-Gpreamp [dB] AT: Total correction Factor except Antenna UR: Receiver Reading Gpreamp: Preamplifier Gain AFactor: Antenna Factor at 3m During the test, the total correction Factor AT and AFactor were built in test software. Note: All radiated emission tests were performed in X, Y, Z axis direction. And only the worst axis test condition was recorded in this test report A.Test Verdict: Frequency (MHz) Detector Antenna Max. Emission E (dBµV/m) Limit (dBµV/m) Verdict 920.0 920.4 920.8 QP Horizontal QP Horizontal QP Horizontal 88.87 88.15 89.05 93.98 93.98 93.98 PASS PASS PASS MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: [email protected] Page 15 of 26 REPORT No.SZ21070001W02 2.5. Radiated Emission and Field Strength of Harmonics 2.5.1. Requirement According to section 15.249(a), the field strength of emissions from intentional radiators operated within these frequency bands shall comply with the following: Fundamental frequency Field strength of fundamental (millivolts/meter) Field strength of harmonics (microvolts/meter) 902-928 MHz 50 500 2400-2483.5 MHz 50 500 5725-5875 MHz 50 500 24.0-24.25 GHz 250 2500 According to section 15.249(d), Emission Radiated outside of the specified frequency bands, except for harmonics, shall be attenuated by at least 50dB below the level of the fundamental or to the general radiated emission limits in Section 15.209: Frequency (MHz) Field Strength Measurement (µV/m) Distance (m) Field Strength Limitation at 3m Measurement Distance (uV/m) (dBuV/m) 0.009 - 0.490 2400/F(kHz) 300 10000* 2400/F(KHz) 20log 2400/F(KHz) + 80 0.490 - 1.705 24000/F(kHz) 30 100* 2400/F(KHz) 20log 2400/F(KHz) + 40 1.705 - 30.0 30 30 100*30 20log 30 + 40 30 - 88 100 3 100 20log 100 88 - 216 150 3 150 20log 150 216 - 960 200 3 200 20log 200 Above 960 500 3 500 20log 500 According to section 15.249(e), for frequencies above 1000MHz, the above field strength limits are based on average limits. The peak field strength of any emission shall not exceed the maximum permitted average limits specified above by more than 20dB under any condition of modulation. Note: 1) The tighter limit shall apply at the boundary between two frequency range. 2) Limitation expressed in dBuV/m is calculated by 20log Emission Level(uV/m). 3) If measurement is made at 3m distance, then F.S Limitation at 3m distance is adjusted by using the formula of Ld1 = Ld2 * (d2/d1)2. Example: F.S Limit at 30m distance is 30uV/m, then F.S Limitation at 3m distance is adjusted as Ld1 = L1 = 30uV/m * (10)2 = 100 * 30uV/m MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: [email protected] Page 16 of 26 2.5.2. Test Description A.Test Setup: 1) For radiated emissions from 9kHz to 30MHz REPORT No.SZ21070001W02 2) For radiated emissions from 30MHz to1GHz MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: [email protected] Page 17 of 26 3) For radiated emissions above 1GHz REPORT No.SZ21070001W02 The EUT is placed on a non-conducting table 80 cm above the ground plane for measurement below 1GHz; 1.5 m above the ground plane for measurement above 1GHz.The antenna to EUT distance is 3meters. The EUT is configured in accordance with ANSI C63.10. The EUT is set to transmit in a continuous mode. For measurements below 30MHz, the emission limits shown in the above table are based on measurements employing a CISPR quasi-peak detector except for the frequency bands 9kHz-90 kHz, 110kHz-490 kHz. Radiated emission limits in these two bands are based on measurements employing an average detector. For measurements below 1GHz the resolution bandwidth is set to 100kHz for peak detection measurements or 120kHz for quasi-peak detection measurements. Peak detection is used unless otherwise noted as quasi-peak. For measurements above 1GHz the resolution bandwidth is set to 1MHz, the video band width is set to 3MHz for peak measurements and as applicable for average measurements. The frequency range of interest is monitored at a fixed antenna height and EUT azimuth. The EUT is rotated through 360 degrees to maximize emissions received. The antenna is scanned from 1 to 4 meters above the ground plane to further maximize the emission. Measurements are made with the antenna polarized in both the vertical and the horizontal positions. MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: [email protected] Page 18 of 26 REPORT No.SZ21070001W02 2.5.3. Test Result According to ANSI C63.10, because of peak detection will yield amplitudes equal to or greater than amplitudes measured with the quasi-peak (or average) detector, the measurement data from a spectrum analyzer peak detector will represent the worst-case results, if the peak measured value complies with the quasi-peak (or average) limit, it is unnecessary to perform an quasi-peak measurement (or average). The measurement results are obtained as below: E [dBV/m] =UR + AT + AFactor [dB]; AT =LCable loss [dB]-Gpreamp [dB] AT: Total correction Factor except Antenna UR: Receiver Reading Gpreamp: Preamplifier Gain AFactor: Antenna Factor at 3m During the test, the total correction Factor AT and AFactor were built in test software. Note 1: All radiated emission tests were performed in X, Y, Z axis direction. And only the worst axis test condition was recorded in this test report. Note 2: The low frequency, which started from 9kHz to 30MHz, was pre-scanned and the result which was 20dB lower than the limit line per 15.31(o) was not reported. MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: [email protected] Page 19 of 26 Plot for Channel 1 REPORT No.SZ21070001W02 Fre. (MHz) 920.460 1839.900 2372.700 2759.900 3680.400 7234.300 Pk (dBV/m) 74.72 59.83 56.51 58.34 50.67 59.47 QP AV Limit-PK Limit-QP Limit-AV (dBV/m) (dBV/m) (dBV/m) (dBV/m) (dBV/m) N/A N/A N/A 46.00 N/A N/A 39.95 74.00 N/A 54.00 N/A 33.89 74.00 N/A 54.00 N/A 37.89 74.00 N/A 54.00 N/A N/A 74.00 N/A 54.00 N/A 31.08 74.00 N/A 54.00 (Antenna Horizontal, 30MHz to 10GHz) Antenna Horizontal Horizontal Horizontal Horizontal Horizontal Horizontal Verdict N/A PASS PASS PASS PASS PASS Fre. (MHz) 919.490 1839.900 2373.400 2760.000 3331.120 3680.100 Pk (dBV/m) 78.26 60.18 55.25 59.53 49.79 49.09 QP AV Limit-PK Limit-QP Limit-AV (dBV/m) (dBV/m) (dBV/m) (dBV/m) (dBV/m) N/A N/A N/A 46.00 N/A N/A 39.77 74.00 N/A 54.00 N/A 33.17 74.00 N/A 54.00 N/A 38.91 74.00 N/A 54.00 N/A N/A 74.00 N/A 54.00 N/A N/A 74.00 N/A 54.00 (Antenna Vertical, 30MHz to 10GHz) Antenna Vertical Vertical Vertical Vertical Vertical Vertical Verdict N/A PASS PASS PASS PASS PASS MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: [email protected] Page 20 of 26 Plot for Channel 3 REPORT No.SZ21070001W02 Fre. (MHz) 920.460 1840.700 2370.900 2761.200 3681.880 7234.500 Pk (dBV/m) 75.98 60.01 55.19 58.41 48.65 55.20 QP AV Limit-PK Limit-QP Limit-AV (dBV/m) (dBV/m) (dBV/m) (dBV/m) (dBV/m) N/A N/A N/A 46.00 N/A N/A 37.95 74.00 N/A 54.00 N/A 33.23 74.00 N/A 54.00 N/A 38.63 74.00 N/A 54.00 N/A N/A 74.00 N/A 54.00 N/A 32.04 74.00 N/A 54.00 (Antenna Horizontal, 30MHz to 10GHz) Antenna Horizontal Horizontal Horizontal Horizontal Horizontal Horizontal Verdict N/A PASS PASS PASS PASS PASS Fre. (MHz) 920.460 1840.800 2369.400 2761.200 3681.880 7235.300 Pk (dBV/m) 77.89 60.04 56.79 57.67 49.00 54.98 QP AV Limit-PK Limit-QP Limit-AV (dBV/m) (dBV/m) (dBV/m) (dBV/m) (dBV/m) N/A N/A N/A 46.00 N/A N/A 37.99 74.00 N/A 54.00 N/A 32.67 74.00 N/A 54.00 N/A 36.90 74.00 N/A 54.00 N/A N/A 74.00 N/A 54.00 N/A 31.08 74.00 N/A 54.00 (Antenna Vertical, 30MHz to 10GHz) Antenna Vertical Vertical Vertical Vertical Vertical Vertical Verdict N/A PASS PASS PASS PASS PASS MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: [email protected] Page 21 of 26 Plot for Channel 5 REPORT No.SZ21070001W02 Fre. (MHz) 920.460 1841.500 2370.400 2762.300 5804.100 7234.500 Pk (dBV/m) 76.97 60.10 55.15 58.06 55.19 53.70 QP AV Limit-PK Limit-QP Limit-AV (dBV/m) (dBV/m) (dBV/m) (dBV/m) (dBV/m) N/A N/A N/A 46.00 N/A N/A 39.72 74.00 N/A 54.00 N/A 33.80 74.00 N/A 54.00 N/A 38.53 74.00 N/A 54.00 N/A 34.40 74.00 N/A 54.00 N/A 32.51 74.00 N/A 54.00 (Antenna Horizontal, 30MHz to 10GHz) Antenna Horizontal Horizontal Horizontal Horizontal Horizontal Horizontal Verdict N/A PASS PASS PASS PASS PASS Fre. (MHz) 920.460 1841.600 2370.300 2762.200 3683.100 7236.200 Pk (dBV/m) 80.72 66.50 67.34 59.12 51.97 60.09 QP AV Limit-PK Limit-QP Limit-AV (dBV/m) (dBV/m) (dBV/m) (dBV/m) (dBV/m) N/A N/A N/A 46.00 N/A N/A 45.55 74.00 N/A 54.00 N/A 36.66 74.00 N/A 54.00 N/A 38.46 74.00 N/A 54.00 N/A 35.58 74.00 N/A 54.00 N/A 32.75 74.00 N/A 54.00 (Antenna Vertical, 30MHz to 10GHz) Antenna Vertical Vertical Vertical Vertical Vertical Vertical Verdict N/A PASS PASS PASS PASS PASS MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: [email protected] Page 22 of 26 Annex A Test Uncertainty REPORT No.SZ21070001W02 Where relevant, the following measurement uncertainty levels have been estimated for test performed on the EUT as specified in CISPR 16-1-2: Test Items Uncertainty Bandwidth ±5% Radiated Emission ±2.95dB This uncertainty represent an expanded uncertainty expressed at approximately the 95% confidence level using a coverage factor of k=2. MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: [email protected] Page 23 of 26 REPORT No.SZ21070001W02 Annex B Testing Laboratory Information 1. Identification of the Responsible Testing Laboratory Laboratory Name: Laboratory Address: Telephone: Facsimile: Shenzhen Morlab Communications Technology Co., Ltd. FL.3, Building A, FeiYang Science Park, No.8 LongChang Road, Block 67, BaoAn District, ShenZhen, GuangDong Province, P. R. China +86 755 36698555 +86 755 36698525 2. Identification of the Responsible Testing Location Name: Address: Shenzhen Morlab Communications Technology Co., Ltd. FL.3, Building A, FeiYang Science Park, No.8 LongChang Road, Block 67, BaoAn District, ShenZhen, GuangDong Province, P. R. China 3. Facilities and Accreditations All measurement facilities used to collect the measurement data are located at FL.3, Building A, FeiYang Science Park, Block 67, BaoAn District, Shenzhen, 518101 P. R. China. The test site is constructed in conformance with the requirements of ANSI C63.10-2013 and CISPR Publication 22; the FCC designation number is CN1192, the test firm registration number is 226174. MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: [email protected] Page 24 of 26 REPORT No.SZ21070001W02 4. Test Equipments Utilized 4.1 Radiated Test Equipments Equipment Name Serial No. Receiver MY54130016 Test Antenna Bi-Log 9163-519 Test Antenna Loop 1519-022 Test Antenna Horn 01774 Test Antenna BBHA9170 Horn #774 Coaxial cable (N male) CB04 (9KHz-30MHz) Coaxial cable (N male) CB02 (30MHz-26GHz) Coaxial cable (N male) CB03 (30MHz-26GHz) 1-18GHz pre-Amplifier MA02 18-26.5GHz pre-Amplifier MA03 Anechoic Chamber N/A Type N9038A VULB 9163 FMZB1519 BBHA 9120D BBHA9170 EMC04 EMC02 EMC03 TS-PR18 TS-PR18 9m*6m*6m Manufacturer Agilent Schwarzbeck Schwarzbeck Schwarzbeck Schwarzbeck Morlab Morlab Morlab Rohde& Schwarz Rohde& Schwarz CRT Cal. Date 2019.07.26 2019.05.08 2019.02.15 2019.07.26 2019.07.26 N/A N/A N/A 2019.05.08 2019.05.08 2017.11.19 Cal. Due 2020.07.25 2020.05.09 2020.02.14 2020.07.25 2020.07.25 N/A N/A N/A 2020.05.09 2020.05.09 2020.11.18 MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: [email protected] Page 25 of 26 REPORT No.SZ21070001W02 4.2 Conducted Emission Test Equipments Equipment Name Serial No. Type Receiver MY56400093 N9038A LISN 812744 NSLK 8127 Pulse Limiter (20dB) 9391 VTSD 9561-D Coaxial cable(BNC) (30MHz-26GHz) CB01 EMC01 Manufacturer KEYSIGHT Schwarzbeck Schwarzbeck Morlab Cal. Date 2019.05.08 2019.05.08 2019.05.08 N/A Cal. Due 2020.05.09 2020.05.09 2020.05.09 N/A END OF REPORT MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: [email protected] Page 26 of 26
Related FCC IDs:
- 2AOKB-T8010X - Anker Innovations Limited Homebase 2 [-T8010X] Acrobat Distiller 9.3.2 (Windows)