Measurement Report

IT

12. FCC Test Report WLAN 2.4G R00 Part 2

TP-Link Corporation Limited KC420WS Kasa Cam Outdoor, 24/7 Recording 2AXJ4KC420WS 2AXJ4KC420WS kc420ws

PDF Viewing Options

Not Your Device? Search For Manuals or Datasheets below:


File Info : application/pdf, 11 Pages, 2.30MB

Document DEVICE REPORTGetApplicationAttachment.html?id=5156314
Test Mode

TX G Mode

Channel
01 06 11

Frequency (MHz) 2412
2437
2462

CH01

Report No.: BTL-FCCP-1-2101C259

6 dB Bandwidth (MHz) 16.42 16.42 16.42
CH06

6 dB Bandwidth Min. Limit (kHz) 500
500
500

Result
Complies Complies Complies

CH11

Channel
01 06 11

Frequency (MHz) 2412
2437
2462

CH01

99 % Emission Bandwidth (MHz) 17.12 17.12 16.96
CH06

Result Complies Complies Complies
CH11

Page 106 of 116

Report No.: BTL-FCCP-1-2101C259

Test Mode

TX N-20M Mode

Channel
01 06 11

Frequency (MHz) 2412
2437
2462

CH01

6 dB Bandwidth (MHz) 17.62 17.60 17.62
CH06

6 dB Bandwidth Min. Limit (kHz) 500
500
500

Result
Complies Complies Complies

CH11

Channel
01 06 11

Frequency (MHz) 2412
2437
2462

CH01

99 % Emission Bandwidth (MHz) 18.00 18.24 18.24
CH06

Result Complies Complies Complies
CH11

Page 107 of 116

Report No.: BTL-FCCP-1-2101C259
APPENDIX F - MAXIMUM AVERAGE OUTPUT POWER
Page 108 of 116

Report No.: BTL-FCCP-1-2101C259

Test Mode

TX B Mode

Channel
01 06 11

Frequency (MHz)
2412 2437 2462

Average Output Power (dBm)
19.97 19.92 19.04

Duty Factor
0.00 0.00 0.00

Output Power + Duty Factor
(dBm) 19.97
19.92
19.04

Max. Limit (dBm)
30.00 30.00 30.00

Max. Limit (W)

Result

1.0000 1.0000 1.0000

Complies Complies Complies

Test Mode

TX G Mode

Channel
01 06 11

Frequency (MHz)
2412 2437 2462

Average Output Power (dBm)
18.96 17.93 17.82

Duty Factor
0.34 0.34 0.34

Output Power + Duty Factor
(dBm) 19.30
18.27
18.16

Max. Limit (dBm)
30.00 30.00 30.00

Max. Limit (W)

Result

1.0000 1.0000 1.0000

Complies Complies Complies

Test Mode

TX N-20M Mode

Channel
01 06 11

Frequency (MHz)
2412 2437 2462

Average Output Power (dBm)
17.79 19.68 16.21

Duty Factor
0.15 0.15 0.15

Output Power + Duty Factor
(dBm) 17.94
19.83
16.36

Max. Limit (dBm)
30.00 30.00 30.00

Max. Limit (W)

Result

1.0000 1.0000 1.0000

Complies Complies Complies

Page 109 of 116

Report No.: BTL-FCCP-1-2101C259
APPENDIX G - CONDUCTED SPURIOUS EMISSIONS
Page 110 of 116

Test Mode

TX B Mode

Bandedge-CH01

Report No.: BTL-FCCP-1-2101C259 Bandedge-CH11

CH01 ­ 10th Harmonic of the fundamental frequency CH06 ­ 10th Harmonic of the fundamental frequency CH11 ­ 10th Harmonic of the fundamental frequency

Page 111 of 116

Test Mode

TX G Mode

Bandedge-CH01

Report No.: BTL-FCCP-1-2101C259 Bandedge-CH11

CH01 ­ 10th Harmonic of the fundamental frequency CH06 ­ 10th Harmonic of the fundamental frequency CH11 ­ 10th Harmonic of the fundamental frequency

Page 112 of 116

Test Mode

TX N-20M Mode

Bandedge-CH01

Report No.: BTL-FCCP-1-2101C259 Bandedge-CH11

CH01 ­ 10th Harmonic of the fundamental frequency CH06 ­ 10th Harmonic of the fundamental frequency CH11 ­ 10th Harmonic of the fundamental frequency

Page 113 of 116

Report No.: BTL-FCCP-1-2101C259
APPENDIX H - POWER SPECTRAL DENSITY
Page 114 of 116

Test Mode

TX B Mode

Channel
01 06 11

Frequency (MHz) 2412
2437
2462

CH01

Report No.: BTL-FCCP-1-2101C259

Power Spectral Density (dBm/3kHz) -5.15 -4.91 -5.64
CH06

Max. Limit (dBm/3kHz)
8
8
8

Result
Complies Complies Complies

CH11

Test Mode

TX G Mode

Channel
01 06 11

Frequency (MHz) 2412
2437
2462

CH01

Power Spectral Density (dBm/3kHz) -7.72 -8.92 -8.74
CH06

Max. Limit (dBm/3kHz)
8
8
8

Result
Complies Complies Complies

CH11

Page 115 of 116

Test Mode

TX N-20M Mode

Channel
01 06 11

Frequency (MHz) 2412
2437
2462

CH01

Report No.: BTL-FCCP-1-2101C259

Power Spectral Density (dBm/3kHz) -8.81 -6.24 -5.61
CH06

Max. Limit (dBm/3kHz)
8
8
8

Result
Complies Complies Complies

CH11

End of Test Report Page 116 of 116



Related FCC IDs: