ESIM EMC Test rapor taslagi
Sedat Eser
Test Report
Elo Touch Solutions, Inc. EMCM100C POS RBWEMCM100C RBWEMCM100C emcm100c
Not Your Device? Search For Manuals or Datasheets below:
File Info : application/pdf, 41 Pages, 4.99MB
Document DEVICE REPORTGetApplicationAttachment.html?id=7386309DEKRA Testing and Certification (Suzhou) Co., Ltd. No.99 Hongye Rd., Suzhou Industrial Park, Suzhou, 215006, Jiangsu, China TEL: +86-512-6251-5088 / FAX: +86-512-6251-5098 Test report No: 2390387R-RF-US-P07V01 FCC & ISED TEST REPORT Product Name Trademark Model and /or type reference FCC ID IC Applicant's name / address Test method requested, standard Verdict Summary POS Elo EMC-M100C RBWEMCM100C 10757B-EMCM100C Elo Touch Solutions, Inc 670 N. McCarthy Blvd., Suite 100, Milpitas, CA 95035, USA. 47 CFR FCC Part 22 & 24 & 27 & 90 ANSI C63.26: 2015 ANSI/TIA-603-E: 2016 RSS-130 Issue 2 RSS-132 Issue 4 RSS-139 Issue 4 RSS-199 Issue 4 RSS-133 Issue 6 Amendment 1 RSS-Gen Issue 5 Amendment 2 IN COMPLIANCE Documented by (name / position & signature) Jun Xu / Project Engineer Approved by (name / position & signature) Jack Zhang / Manager Date of issue Report Version Report template No 2024-05-28 V1.0 Template_Part 22&24&27&90-RF-V1.0 DEKRA Testing and Certification (Suzhou) Co., Ltd. No.99 Hongye Rd., Suzhou Industrial Park, Suzhou, 215006, Jiangsu, China TEL: +86-512-6251-5088 / FAX: +86-512-6251-5098 INDEX page General conditions ............................................................................................................................................................ 3 Environmental conditions .................................................................................................................................................. 3 Possible test case verdicts ................................................................................................................................................ 4 Abbreviations..................................................................................................................................................................... 4 Document History.............................................................................................................................................................. 5 Remarks and Comments .................................................................................................................................................. 5 Used Equipment................................................................................................................................................................ 6 Uncertainty ........................................................................................................................................................................ 8 1 General Information ................................................................................................................................................. 9 1.1 General Description of the Item(s)................................................................................................................. 9 1.2 Antenna Information .................................................................................................................................... 11 1.3 Channel List ................................................................................................................................................. 12 2 Description of Test Setup....................................................................................................................................... 14 2.1 Auxiliary equipment / Test software for the EUT ......................................................................................... 14 2.2 Test Configuration / Block diagram used for tests....................................................................................... 15 2.3 Testing process ........................................................................................................................................... 16 3 Verdict summary section........................................................................................................................................ 17 3.1 Standards .................................................................................................................................................... 17 3.2 Deviation(s) from the Standard(s) / Test Specification(s)............................................................................ 17 3.3 Overview of results ...................................................................................................................................... 18 3.4 Test Facility.................................................................................................................................................. 19 4 Test Results ........................................................................................................................................................... 20 4.1 Effective (Isotropic) Radiated Power Output ............................................................................................... 20 4.1.1 Limit ................................................................................................................................................... 20 4.1.2 Test Setup ......................................................................................................................................... 20 4.1.3 Test Procedure .................................................................................................................................. 21 4.1.4 Test Data ........................................................................................................................................... 22 4.2 Radiated Emissions ..................................................................................................................................... 41 4.2.1 Limit ................................................................................................................................................... 41 4.2.2 Test Setup ......................................................................................................................................... 42 4.2.3 Test Procedure .................................................................................................................................. 42 4.2.4 Test Data ........................................................................................................................................... 43 5 Test setup photo and EUT Photo ................................................................................................................ 95 Report no.: 2390387R-RF-US-P07V01 Page 2 / 95 DEKRA Testing and Certification (Suzhou) Co., Ltd. No.99 Hongye Rd., Suzhou Industrial Park, Suzhou, 215006, Jiangsu, China TEL: +86-512-6251-5088 / FAX: +86-512-6251-5098 COMPETENCES AND GUARANTEES DEKRA is a testing laboratory competent to carry out the tests described in this report. In order to assure the traceability to other national and international laboratories, DEKRA has a calibration and maintenance program for its measurement equipment. DEKRA guarantees the reliability of the data presented in this report, which is the result of the measurements and the tests performed to the item under test on the date and under the conditions stated in the report and it is based on the knowledge and technical facilities available at DEKRA at the time of performance of the test. DEKRA is liable to the client for the maintenance of the confidentiality of all information related to the item under test and the results of the test. The results presented in this Test Report apply only to the particular item under test established in this document. IMPORTANT: No parts of this report may be reproduced or quoted out of context, in any form or by any means, except in full, without the previous written permission of DEKRA. GENERAL CONDITIONS Test Location Date(receive sample) Date (start test) Date (finish test) No. 99, Hongye Road, Suzhou Industrial Park Suzhou, 215006, P.R. China Dec. 26, 2023 Mar. 01, 2024 Mar. 27, 2024 1. This report is only referred to the item that has undergone the test. 2. This report does not constitute or imply on its own an approval of the product by the Certification Bodies or Competent Authorities. 3. This document is only valid if complete; no partial reproduction can be made without previous written permission of DEKRA. 4. This test report cannot be used partially or in full for publicity and/or promotional purposes without previous written permission of DEKRA. ENVIRONMENTAL CONDITIONS The climatic conditions during the tests are within the limits specified by the manufacturer for the operation of the EUT and the test equipment. The climatic conditions during the tests were within the following limits: Ambient temperature Relative Humidity air 15 °C 35 °C 30% - 60% If explicitly required in the basic standard or applied product / product family standard the climatic values are recorded and documented separately in this test report. Report no.: 2390387R-RF-US-P07V01 Page 3 / 95 DEKRA Testing and Certification (Suzhou) Co., Ltd. No.99 Hongye Rd., Suzhou Industrial Park, Suzhou, 215006, Jiangsu, China TEL: +86-512-6251-5088 / FAX: +86-512-6251-5098 POSSIBLE TEST CASE VERDICTS Test case does not apply to test object Test object does meet requirement Test object does not meet requirement Not measured N/A P (Pass) / PASS F (Fail) / FAIL N/M ABBREVIATIONS For the purposes of the present document, the following abbreviations apply: EUT QP CAV AV CDN SAC OATS BW AM PM HCP VCP UN Tx Rx N/A N/M : Equipment Under Test : Quasi-Peak : CISPR Average : Average : Coupling Decoupling Network : Semi-Anechoic Chamber : Open Area Test Site : Bandwidth : Amplitude Modulation : Pulse Modulation : Horizontal Coupling Plane : Vertical Coupling Plane : Nominal voltage : Transmitter : Receiver : Not Applicable : Not Measured Report no.: 2390387R-RF-US-P07V01 Page 4 / 95 DEKRA Testing and Certification (Suzhou) Co., Ltd. No.99 Hongye Rd., Suzhou Industrial Park, Suzhou, 215006, Jiangsu, China TEL: +86-512-6251-5088 / FAX: +86-512-6251-5098 DOCUMENT HISTORY Report No. 2390387R-RF-US-P07V01 Version V1.0 Description Initial issue of report. Issued Date 2024-05-28 REMARKS AND COMMENTS 1. The equipment under test (EUT) does meet the essential requirements of the stated standard(s)/test(s). 2. This report is limited report related to installation tested module in POS, the customer declared that the RF parameter of the module installed in the host is exactly same with the certificated module. We verified the RF Output Power and Radiated Emissions on the Host. For other test data, please refer to FCC ID: 2APJ4SLM750VA, IC: 23860-SLM750.These test results on a sample of the device are for the purpose of demonstrating Compliance with 47 CFR FCC Part 22 & 24 & 27 & 90, RSS-130 Issue 2,RSS-132 Issue 4, RSS-199 Issue 4,RSS-139 Issue 4,RSS-133 Issue 6 Amendment 1. 3. The measurement result is considered in conformance with the requirement if it is within the prescribed limit, It is not necessary to account the uncertainty associated with the measurement result. 4. The test results relate only to the samples tested. 5. The test report shall not be reproduced without the written approval of DEKRA Testing and Certification (Suzhou) Co., Ltd. 6. This report will not be used for social proof function in China market. 7. DEKRA declines any responsibility with the following test data provided by customer that may affect the validity of result: - Chapter 1.1 General Description of the Item(s); - Chapter 1.2 Antenna Information; - Chapter 1.3 Channel List. Report no.: 2390387R-RF-US-P07V01 Page 5 / 95 DEKRA Testing and Certification (Suzhou) Co., Ltd. No.99 Hongye Rd., Suzhou Industrial Park, Suzhou, 215006, Jiangsu, China TEL: +86-512-6251-5088 / FAX: +86-512-6251-5098 USED EQUIPMENT RF Output Power / TR7 Instrument Manufacturer Model No. Serial No. Cal. Date Wideband Radio Communication Tester R&S CMW 500 170870 2023.05.20 Signal analyzer R&S FSV30 104212 2023.08.26 ESG Vector Signal Generator Agilent E4438C MY49070163 2023.12.11 RF Control Unit Tonscend JS08061 168060022 2023.08.28 PSG Analog Signal Generator Agilent E8257D MY44321116 2023.06.12 High and low temperature and fast temperature change test box ASTUOD ASTDFBT- N/A 225K 2023.07.05 Filter box Tonscend N/A N/A 2023.06.09 Temperature/Humidity Meter RTS RTS-8S RF06 2023.05.19 Test Software Tonscend JS1120 JS1120-8 N/A Next Cal. Firmware Software Date Version Version 2024.05.19 X 4.0.62.11 N/A 2024.08.25 3.40 N/A 2024.12.10 C.05.85 N/A 2024.08.27 N/A N/A 2024.06.11 C.06.27 N/A 2024.07.04 N/A 2024.06.08 N/A 2024.05.18 N/A N/A N/A N/A N/A N/A V3.1.46 Radiated Emissions (9KHz-1GHz) / AC2 Instrument Manufacturer Model No. EMI Test Receiver R&S ESCI Loop Antenna R&S HFH2-Z2E Bilog Antenna Teseq GmbH CBL6112D Coaxial Cable Huber+Suhner SUCOFLEX 106 Temperature/Humidity Meter RTS Dekra test software Dekra RTS-8S N/A Serial No. Cal. Date Next Cal. Firmware Software Date Version version 100573 2024.02.06 2025.02.05 4.42 SP3 N/A 101149 2023.04.25 2024.04.24 N/A N/A 27613 2023.09.13 2024.09.12 N/A N/A AC2-C 2023.05.21 2024.05.20 N/A N/A AC2-TH 2023.05.19 2024.05.18 N/A N/A N/A N/A N/A N/A 3 Report no.: 2390387R-RF-US-P07V01 Page 6 / 95 DEKRA Testing and Certification (Suzhou) Co., Ltd. No.99 Hongye Rd., Suzhou Industrial Park, Suzhou, 215006, Jiangsu, China TEL: +86-512-6251-5088 / FAX: +86-512-6251-5098 Radiated Emissions (1GHz-40GHz)/ AC5 Instrument EXA Spectrum Analyzer Manufacturer Model No. Keysight N9020B Serial No. MY60112218 Cal. Date 2023.11.0 8 Next Cal. Firmwar Softwar Date e e Version version 2024.11.0 7 A.31.05 N/A Pre-Amplifier SKET LNPA_0118 SK202109010 2023.05.1 G-45 1 4 2024.05.1 3 N/A N/A DRG Horn Antenna ETS-Lindgren 3117 123988 2023.11.0 7 2024.11.0 6 N/A N/A Filter Switch Box MVE MSW-F196 C070001S 2023.05.2 1 2024.05.2 0 N/A N/A Temperature/Humidi ty Meter RTS RTS-8S AC5-TH 2023.05.1 9 2024.05.1 8 N/A N/A Coaxial Cable ROSENBERG LA1-C011- ER 2000/3000 AC5-40G-2 2023.05.2 1 2024.05.2 0 N/A N/A Cable Rosenberger LA1-C0111000 0523 2023.05.2 1 2024.05.2 0 N/A N/A Dekra test software Wideband Radio Communication Tester Dekra R&S N/A N/A CMW 500 170870 N/A N/A N/A 3 2023.05.2 0 2024.05.1 9 V 3.7.90 N/A Report no.: 2390387R-RF-US-P07V01 Page 7 / 95 DEKRA Testing and Certification (Suzhou) Co., Ltd. No.99 Hongye Rd., Suzhou Industrial Park, Suzhou, 215006, Jiangsu, China TEL: +86-512-6251-5088 / FAX: +86-512-6251-5098 UNCERTAINTY Uncertainties have been calculated according to the DEKRA internal document. The reported expanded uncertainties are based on a standard uncertainty multiplied by a coverage factor of k=2, providing a level of confidence of approximately 95%.The Uncertainties is complice with standard required as below. RF Output Power Radiated Emissions Test item Uncertainty ±1.2 dB ±3.2 dB Report no.: 2390387R-RF-US-P07V01 Page 8 / 95 DEKRA Testing and Certification (Suzhou) Co., Ltd. No.99 Hongye Rd., Suzhou Industrial Park, Suzhou, 215006, Jiangsu, China TEL: +86-512-6251-5088 / FAX: +86-512-6251-5098 1 GENERAL INFORMATION 1.1 General Description of the Item(s) Product Name ............................... : Model No. ...................................... : Trademark. .................................... : FCC ID........................................... : IC ................................................... : Hardware Version.......................... : Software Version ........................... : Manufacturer ................................. : Manufacturer Address ................... : Factory........................................... : Factory address............................. : POS EMC-M100C Elo RBWEMCM100C 10757B-EMCM100C V1.00 T14 Elo Touch Solutions, Inc 670 N. McCarthy Blvd., Suite 100, Milpitas, CA 95035, USA. ShuoGe Intelligent Technology Co.,Ltd. Room 308-310, Building 1, No.2 8th Road, Baiyang Street, Qiantang New Area,Hangzhou City, Zhejiang Province, P.R. China(310018) Wireless specifiction ....................... : WCDMA Support Band(s) ............................. : Band 2 / Band 4/ Band 5 Uplink Frequency Band 2: 1850-1910 MHz Band 4: 1710-1755 MHz Band 5: 824-849 MHz Downlink Frequency Band 2: 1930-1990 MHz Band 4: 2110-2155 MHz Band 5: 869-894 MHz Type of Modulation ......................... : BPSK, QPSK, 16QAM Wireless specifiction ....................... : LTE Support Band(s) Band 2/ Band 4/ Band 5/ Band 12/ Band 13/ Band17/ Band 25/ Band 26/ Band 41 Uplink Frequency Band 2: 1850-1910 MHz Band 4: 1710-1755 MHz Band 5: 824-849 MHz Band 12: 699-716 MHz Band 13: 777-787 MHz Band 17: 704-716 MHz Band 25: 1850-1915 MHz Band 26 (FCC): 814-849 MHz Band 26 (IC): 824-849 MHz Band 41: 2469-2690 MHz Downlink Frequency Band 2: 1930-1990 MHz Band 4: 2110-2155 MHz Band 5: 869-894 MHz Band 12: 729-746 MHz Band 13: 746-756 MHz Band 17: 734-746 MHz Band 25: 1930-1995 MHz Report no.: 2390387R-RF-US-P07V01 Page 9 / 95 DEKRA Testing and Certification (Suzhou) Co., Ltd. No.99 Hongye Rd., Suzhou Industrial Park, Suzhou, 215006, Jiangsu, China TEL: +86-512-6251-5088 / FAX: +86-512-6251-5098 Band 26(FCC): 859-894 MHz Band 26(IC): 869-894 MHz Band 41: 2469-2690 MHz Type of Modulation ......................... : QPSK, 16QAM Rated power supply.................... : Adapter Model ............................ : Mounting position ....................... : Voltage and Frequency AC: 220 - 240 V, 50/60 Hz AC: 100 - 240 V, 50/60 Hz DC: 24 Vdc Poe: Adapter: UES45LCP-SPC Input: 100-240V ~ 50/60Hz,1.3A Output: 5.0V/3.0A,15.0W; 9.0V/3.0A, 27.0W; 12.0V/3.0A,36.0W; 15V/3.0A,45W; 20V/2.25A,45W Max Tabletop equipment Wall/Ceiling mounted equipment Floor standing equipment Hand-held/Portable equipment Other: Report no.: 2390387R-RF-US-P07V01 Page 10 / 95 DEKRA Testing and Certification (Suzhou) Co., Ltd. No.99 Hongye Rd., Suzhou Industrial Park, Suzhou, 215006, Jiangsu, China TEL: +86-512-6251-5088 / FAX: +86-512-6251-5098 1.2 Antenna Information Antenna model / type number ........ : Antenna serial number ................... : Antenna Delivery ........................... : Antenna technology........................ : N/A N/A 1TX + 1RX 2TX + 2RX SISO MIMO Antenna Type ................................. : External Internal Antenna Gain ................................. : Band 2: 0.64 dBi Band 4: 0.84dBi Band 5: -1.05 dBi Band 12: -6.51dBi Band 13: -2.44dBi Band 17: -6.51 dBi Band 25: 0.64dBi Band 26: -0.40dBi Band 41: 2.84 dBi CDD Beam-forming Dipole Sectorized PIFA FPC Ceramic Chip Others.............. Report no.: 2390387R-RF-US-P07V01 Page 11 / 95 DEKRA Testing and Certification (Suzhou) Co., Ltd. No.99 Hongye Rd., Suzhou Industrial Park, Suzhou, 215006, Jiangsu, China TEL: +86-512-6251-5088 / FAX: +86-512-6251-5098 1.3 Channel List WCDMA Working Frequency of Each Channel: WCDMA Band Channel Frequency(MHz) Band2 9262 1852.4 Band4 1312 1712.4 Band5 4132 836.6 Channel 9400 1413 4183 Frequency(MHz) 1880 1732.6 836.6 Channel Frequency(MHz) 9538 1907.6 1513 1752.6 4233 846.6 LTE Working Frequency of Each Channel: LTE Band Channel Frequency(MHz) Band2 (BW=1.4M) 18607 1850.7 Band2 (BW=3M) 18615 1851.5 Band2 (BW=5M) 18625 1852.5 Band2 (BW=10M) 18650 1855.0 Band2 (BW=15M) 18675 1857.5 Band2 (BW=20M) 18700 1860.0 Band4 (BW=1.4M) 19957 1710.7 Band4 (BW=3M) 19965 1711.5 Band4 (BW=5M) 19975 1712.5 Band4 (BW=10M) 20000 1715.0 Band5 (BW=1.4M) 20407 824.7 Band5 (BW=3M) 20415 825.5 Band5 (BW=5M) 20425 826.5 Band5 (BW=10M) 20450 829.0 Band12 (BW=1.4M) 23017 699.7 Band12 (BW=3M) 23025 700.5 Band12 (BW=5M) 23035 701.5 Band12 (BW=10M) 23060 704.0 Band13 (BW=5M) 23205 779.5 Band13 (BW=10M) -- -- Band17 (BW=5M) 23755 706.5 Band17 (BW=10M) 23780 709.0 Band25 (BW=1.4M) 26047 1850.7 Band25 (BW=3M) 26055 1851.5 Band25 (BW=5M) 26065 1852.5 Band25 (BW=10M) 26090 1855.0 Band25 (BW=15M) 26115 1857.5 Band25 (BW=20M) 26140 1860.0 Band26 (BW=1.4M) 26697 814.7 Band26 (BW=3M) 26705 815.5 Band26 (BW=5M) 26715 816.5 Band26 (BW=10M) 26740 819 Band26 (BW=15M) 26765 821.5 Channel 18900 18900 18900 18900 18900 18900 20175 20175 20175 20175 20525 20525 20525 20525 23095 23095 23095 23095 23230 23230 23790 23790 26340 26340 26340 26340 26340 26340 26865 26865 26865 26865 26865 Frequency(MHz) Channel Frequency(MHz) 1880 19193 1909.3 1880 19185 1908.5 1880 19175 1907.5 1880.0 19150 1905.0 1880.0 19125 1902.5 1880.0 19100 1900.0 1732.5 20393 1754.3 1732.5 20385 1753.5 1732.5 20375 1752.5 1732.5 20350 1750.0 836.5 20643 848.3 836.5 20635 847.5 836.5 20625 846.5 836.5 20600 844.0 707.5 23173 715.3 707.5 714.5 23165 707.5 23155 713.5 707.5 23130 711.0 782.0 23255 784.5 782.0 -- -- 710.0 23825 713.5 710.0 23800 711.0 1880.0 26683 1914.3 1880.0 26675 1913.5 1880.0 26665 1912.5 1880.0 26640 1910.0 1880.0 26615 1907.5 1880.0 26590 1905.0 831.5 27033 848.3 831.5 27025 847.5 831.5 27015 846.5 831.5 26990 844 831.5 26965 841.5 Report no.: 2390387R-RF-US-P07V01 Page 12 / 95 DEKRA Testing and Certification (Suzhou) Co., Ltd. No.99 Hongye Rd., Suzhou Industrial Park, Suzhou, 215006, Jiangsu, China TEL: +86-512-6251-5088 / FAX: +86-512-6251-5098 Band41 (BW=5M) Band41 (BW=10M) Band41 (BW=15M) Band41 (BW=20M) Band26 - IC (BW=1.4M) Band26 - IC (BW=3M) Band26 - IC (BW=5M) Band26 - IC (BW=10M) Band26 - IC (BW=15M) 40265 40290 40315 40340 26797 26805 26815 26840 26865 2557.5 2560 2562.5 2565 824.7 825.5 826.5 829 831.5 40740 40740 40740 40740 26915 26915 26915 26915 26915 2605 2605 2605 2605 836.5 836.5 836.5 836.5 836.5 41215 41190 41165 41140 27033 27025 27015 26990 26965 2652.5 2650 2647.5 2645 848.3 847.5 846.5 844 841.5 Note: The General Description of the Item , antenna information, Channel List for the EUT in clause 1 are provided and confirmed by the client. Report no.: 2390387R-RF-US-P07V01 Page 13 / 95 DEKRA Testing and Certification (Suzhou) Co., Ltd. No.99 Hongye Rd., Suzhou Industrial Park, Suzhou, 215006, Jiangsu, China TEL: +86-512-6251-5088 / FAX: +86-512-6251-5098 2 DESCRIPTION OF TEST SETUP 2.1 Operating mode(s) used for tests During the tests the following operating mode(s) has(have) been used. Mode 1: Transmit by WCDMA Band2 Mode 2: Transmit by WCDMA Band4 Mode 3: Transmit by WCDMA Band5 Mode 4: Transmit by LTE Band2 Mode 5: Transmit by LTE Band4 Mode 6: Transmit by LTE Band5 Test Mode Mode 7: Transmit by LTE Band12 Mode 8: Transmit by LTE Band13 Mode 9: Transmit by LTE Band17 Mode 10: Transmit by LTE Band25 Mode 11: Transmit by LTE Band26 Mode 12: Transmit by LTE Band41 Mode 13: Transmit by LTE Band26-IC Note : For portable device, radiated tests was verified over X, Y, Z axis, and shown the worst case on this report. 2.2 Auxiliary equipment / Test software for the EUT Auxiliary equipment N/A N/A N/A software N/A Type / Version N/A N/A N/A Type / Version N/A Manufacturer N/A N/A N/A Manufacturer N/A Supplied by N/A N/A N/A Supplied by N/A Accessories Information (2)USB Control Cable (3)USB Control Cable Length used during test [m] 1 8 Cable Attached during test Shielded Report no.: 2390387R-RF-US-P07V01 Page 14 / 95 DEKRA Testing and Certification (Suzhou) Co., Ltd. No.99 Hongye Rd., Suzhou Industrial Park, Suzhou, 215006, Jiangsu, China TEL: +86-512-6251-5088 / FAX: +86-512-6251-5098 2.3 Test Configuration / Block diagram used for tests Test setup Diagram- Conducted test Test setup Diagram- Radiated Emission Report no.: 2390387R-RF-US-P07V01 Page 15 / 95 DEKRA Testing and Certification (Suzhou) Co., Ltd. No.99 Hongye Rd., Suzhou Industrial Park, Suzhou, 215006, Jiangsu, China TEL: +86-512-6251-5088 / FAX: +86-512-6251-5098 2.4 Testing process 1 Setup the EUT and simulators as shown on above. 2 Turn on the power of all equipment. 3 EUT Communicate with CMW 500, then select channel to test. Report no.: 2390387R-RF-US-P07V01 Page 16 / 95 DEKRA Testing and Certification (Suzhou) Co., Ltd. No.99 Hongye Rd., Suzhou Industrial Park, Suzhou, 215006, Jiangsu, China TEL: +86-512-6251-5088 / FAX: +86-512-6251-5098 3 VERDICT SUMMARY SECTION This chapter presents an overview of standards and results. Refer to the next chapters for details of measured test results and applied test levels. 3.1 Standards Standard FCC CFR Title 47 Part 2 FCC CFR Title 47 Part 22 FCC CFR Title 47 Part 24 FCC CFR Title 47 Part 27 FCC CFR Title 47 Part 90 RSS-130 Issue 2 RSS-132 Issue 4 RSS-199 Issue 4 RSS-132 Issue 6 Amendment 1 RSS-139 Issue 4 RSS-Gen Issue 5 Amendment 2 ANSI C63.26 ANSI TIA-603-E KDB971168 D01 v03r01 KDB971168 D02 v02r01 Year 2024 2024 2024 2024 2024 2019 2023 2023 2018 2022 2021 2015 2016 2018 2023 Description Frequency Allocations and Radio Treaty Matters; General Rules and Regulations Public Mobile Services Personal Communications Services Miscellaneous Wireless Communications Services Private land Mobile Radio Services Equipment Operating in the Frequency Bands 617-652 MHz, 663698 MHz, 698-756 MHz and 777-787 MHz Cellular Systems Operating in the Bands 824-849 MHz and 869894 MHz Broadband Radio Service (BRS) Equipment Operating in the Band 2500-2690 MHz 2 GHz Personal Communications Services Advanced Wireless Services Equipment Operating in the Bands 1710-1780 MHz and 2110-2200 MHz General Requirements for Compliance of Radio Apparatus American National Standard for Compliance Testing of Transmitters Used in Licensed Radio Services Land Mobile FM or PM Communications Equipment Measurement and performance Standards Measurement Guidance for Certification of Licensed Digital Transmitters Miscellaneous and Basic Review and Approval Items for Transmitting Equipment Used in Licensed Radio Services 3.2 Deviation(s) from the Standard(s) / Test Specification(s) The following deviation(s) was / were made from the published requirements of the listed standards: N/A. (Please define the deviations from the standard(s) if applicable) Report no.: 2390387R-RF-US-P07V01 Page 17 / 95 DEKRA Testing and Certification (Suzhou) Co., Ltd. No.99 Hongye Rd., Suzhou Industrial Park, Suzhou, 215006, Jiangsu, China TEL: +86-512-6251-5088 / FAX: +86-512-6251-5098 3.3 Overview of results For FCC : Requirement Test case RF Output Power RF Output Power RF Output Power RF Output Power Radiated Emissions Radiated Emissions Radiated Emissions Radiated Emissions Basic standard(s) FCC Part 22 Section 22.913 FCC Part 90 Section 90.635(b) FCC Part 24 Section 24.232 FCC Part 27 Section 27.50 FCC Part 22 Section 22.917 FCC Part 90 Section 90.691 FCC Part 24 Section 24.238 FCC Part 27 Section 27.53 For ISED : Requirement Test case RF Output Power RF Output Power RF Output Power RF Output Power RF Output Power Radiated Emissions Radiated Emissions Radiated Emissions Radiated Emissions Radiated Emissions Basic standard(s) RSS-132 Issue 4 Section 5.4 RSS-133 Issue 6 Section 6.4 RSS-130 Issue 2 Section 4.6 RSS-139 Issue 4 Section 5.4 RSS-199 Issue 4 Section 5.5 RSS-132 Issue 4 Section 5.5 RSS-133 Issue 6 Section 6.5 RSS-130 Issue 2 Section 4.7 RSS-139 Issue 4 Section 5.6 RSS-199 Issue 4 Section 5.6 Verdict PASS PASS PASS PASS PASS PASS PASS PASS Remark Verdict PASS PASS PASS PASS PASS PASS PASS PASS PASS PASS Remark Report no.: 2390387R-RF-US-P07V01 Page 18 / 95 DEKRA Testing and Certification (Suzhou) Co., Ltd. No.99 Hongye Rd., Suzhou Industrial Park, Suzhou, 215006, Jiangsu, China TEL: +86-512-6251-5088 / FAX: +86-512-6251-5098 3.4 Test Facility USA Canada : FCC Designation Number: CN1199 : CAB identifier Number: CN0040 Report no.: 2390387R-RF-US-P07V01 Page 19 / 95 DEKRA Testing and Certification (Suzhou) Co., Ltd. No.99 Hongye Rd., Suzhou Industrial Park, Suzhou, 215006, Jiangsu, China TEL: +86-512-6251-5088 / FAX: +86-512-6251-5098 4 TEST RESULTS 4.1 Effective (Isotropic) Radiated Power Output VERDICT: PASS 4.1.1 Limit Band Standard FCC §2.1046 and §22.913: The ERP of mobile transmitters and auxiliary test transmitters must not 5/26 exceed 7 watts. FCC §90.635: The maximum output power of the transmitter for mobile stations is 100 watts (20 dBw). FCC §2.1046 and §24.232: Mobile and portable stations are limited to 2 watts EIRP. 2/25 The peak-to-average ratio (PAR) of the transmission may not exceed 13 dB. FCC §27.50(c)(10): Portable stations (hand-held devices) in the 600 MHz uplink band and the 698-746 MHz band, and fixed and mobile stations in the 600 MHz uplink band are limited to 3 watts ERP. 12/13/17 FCC §27.50(b)(10): Portable stations (hand-held devices) transmitting in the 746-757 MHz, 776-788 MHz, and 805-806 MHz bands are limited to 3 watts ERP. FCC §27.50(d)(4): Fixed, mobile, and portable (hand-held) stations operating in the 1710-1755 MHz band and mobile and portable stations operating in the 1695-1710 MHz and 1755-1780 MHz bands are 4 limited to 1 watt EIRP. Fixed stations operating in the 1710-1755 MHz band are limited to a maximum antenna height of 10 meters above ground. Mobile and portable stations operating in these bands must employ a means for limiting power to the minimum necessary for successful communications. 41 FCC §27.50(h)(2): Mobile and other user stations. Mobile stations are limited to 2.0 watts EIRP. All user stations are limited to 2.0 watts transmitter output power. 4.1.2 Test Setup Report no.: 2390387R-RF-US-P07V01 Page 20 / 95 DEKRA Testing and Certification (Suzhou) Co., Ltd. No.99 Hongye Rd., Suzhou Industrial Park, Suzhou, 215006, Jiangsu, China TEL: +86-512-6251-5088 / FAX: +86-512-6251-5098 4.1.3 Test Procedure References Rule Chapter Item ANSI C63.26-2015 5.2 RF output power measurement procedures The conducted RF Output Power measurements were made at the RF output terminals of the EUT using the power meter of the Universal Radio Communication tester R&S CMW500, selecting maximum transmission power of the EUT and different modes of modulation. Peak to average ratio(PAPR) is used equation PAPR(dB)=PPK(dBm)-PAVG(dBm), where PPK is measured peak power, and PAVG is measured average power. The maximum equivalent isotropically radiated power(e.i.r.p.) is calculated by adding the declared maximum antenna gain(dBi). The maximum effective radiated power e.r.p. is calculated form the maximum equivalent isotropically radiated power(e.i.r.p.) by subtracting 2.15 dB: E.R.P = E.I.R.P. 2.15 dB Report no.: 2390387R-RF-US-P07V01 Page 21 / 95 DEKRA Testing and Certification (Suzhou) Co., Ltd. No.99 Hongye Rd., Suzhou Industrial Park, Suzhou, 215006, Jiangsu, China TEL: +86-512-6251-5088 / FAX: +86-512-6251-5098 4.1.4 Test Data WCDMA Band2 TX Channel Rx Channel Frequency (MHz) Power RMC 12.2Kbps HSDPA Subtest-1 HSDPA Subtest-2 HSDPA Subtest-3 HSDPA Subtest-4 DC-HSDPA Subtest-1 DC-HSDPA Subtest-2 DC-HSDPA Subtest-3 DC-HSDPA Subtest-4 HSUPA Subtest-1 HSUPA Subtest-2 HSUPA Subtest-3 HSUPA Subtest-4 HSUPA Subtest-5 9262 9400 9538 9662 9800 9938 1852.4 1880 1907.6 Conducted Power(dBm) 22.64 22.69 22.59 21.98 21.90 21.86 21.83 21.63 21.67 21.43 21.39 21.54 21.34 21.41 21.33 21.88 21.87 21.87 21.85 21.58 21.62 21.46 21.37 21.59 21.32 21.42 21.41 21.83 21.80 21.76 20.30 20.26 20.30 21.07 21.01 21.07 20.30 20.25 20.22 21.82 21.76 21.85 WCDMA Band4 TX Channel Rx Channel Frequency (MHz) Power RMC 12.2Kbps HSDPA Subtest-1 HSDPA Subtest-2 HSDPA Subtest-3 HSDPA Subtest-4 DC-HSDPA Subtest-1 DC-HSDPA Subtest-2 DC-HSDPA Subtest-3 DC-HSDPA Subtest-4 HSUPA Subtest-1 HSUPA Subtest-2 HSUPA Subtest-3 HSUPA Subtest-4 HSUPA Subtest-5 1312 1413 1513 1537 1638 1738 1712.4 1732.6 1752.6 Conducted Power(dBm) 22.84 22.92 22.77 22.21 22.06 22.07 22.05 21.85 21.88 21.64 21.62 21.79 21.49 21.60 21.51 22.06 22.10 22.11 22.10 21.81 21.86 21.70 21.56 21.84 21.48 21.59 21.63 22.08 21.96 21.95 20.47 20.47 20.51 21.28 21.20 21.23 20.52 20.49 20.46 21.98 21.98 22.07 9262 9662 1852.4 23.28 22.62 22.47 22.07 21.98 22.52 22.49 22.1 21.96 22.47 20.94 21.71 20.94 22.46 9400 9538 9800 9938 1880 1907.6 EIRP (dBm) 23.33 23.23 22.54 22.5 22.27 22.31 22.03 22.18 22.05 21.97 22.51 22.51 22.22 22.26 22.01 22.23 22.06 22.05 22.44 22.4 20.9 20.94 21.65 21.71 20.89 20.86 22.4 22.49 Verdict Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass 1312 1537 1712.4 23.68 23.05 22.89 22.48 22.33 22.9 22.94 22.54 22.32 22.92 21.31 22.12 21.36 22.82 1413 1513 1638 1738 1732.6 1752.6 EIRP (dBm) 23.76 23.61 22.9 22.91 22.69 22.72 22.46 22.63 22.44 22.35 22.94 22.95 22.65 22.7 22.4 22.68 22.43 22.47 22.8 22.79 21.31 21.35 22.04 22.07 21.33 21.3 22.82 22.91 Verdict Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Report no.: 2390387R-RF-US-P07V01 Page 22 / 95 DEKRA Testing and Certification (Suzhou) Co., Ltd. No.99 Hongye Rd., Suzhou Industrial Park, Suzhou, 215006, Jiangsu, China TEL: +86-512-6251-5088 / FAX: +86-512-6251-5098 WCDMA Band5 TX Channel Rx Channel Frequency (MHz) Power RMC 12.2Kbps HSDPA Subtest-1 HSDPA Subtest-2 HSDPA Subtest-3 HSDPA Subtest-4 DC-HSDPA Subtest-1 DC-HSDPA Subtest-2 DC-HSDPA Subtest-3 DC-HSDPA Subtest-4 HSUPA Subtest-1 HSUPA Subtest-2 HSUPA Subtest-3 HSUPA Subtest-4 HSUPA Subtest-5 4132 4183 4233 4357 4408 4458 826.4 836.6 846.6 Conducted Power(dBm) 23.07 23.16 22.92 22.36 22.22 22.26 22.27 22.01 22.11 21.82 21.81 21.99 21.68 21.84 21.73 22.28 22.25 22.34 22.27 22.00 22.02 21.86 21.75 22.00 21.67 21.83 21.83 22.24 22.16 22.16 20.69 20.63 20.76 21.46 21.38 21.39 20.71 20.69 20.65 22.15 22.22 22.30 4132 4357 826.4 19.87 19.16 19.07 18.62 18.48 19.08 19.07 18.66 18.47 19.04 17.49 18.26 17.51 18.95 4183 4408 836.6 ERP (dBm) 19.96 19.02 18.81 18.61 18.64 19.05 18.8 18.55 18.63 18.96 17.43 18.18 17.49 19.02 4233 4458 846.6 19.72 19.06 18.91 18.79 18.53 19.14 18.82 18.8 18.63 18.96 17.56 18.19 17.45 19.1 Verdict Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Report no.: 2390387R-RF-US-P07V01 Page 23 / 95 DEKRA Testing and Certification (Suzhou) Co., Ltd. No.99 Hongye Rd., Suzhou Industrial Park, Suzhou, 215006, Jiangsu, China TEL: +86-512-6251-5088 / FAX: +86-512-6251-5098 LTE Band2 BW Modulation RB [MHz] Size Channel Frequency (MHz) 20 QPSK 1 20 QPSK 1 20 QPSK 1 20 QPSK 50 20 QPSK 50 20 QPSK 50 20 QPSK 100 RB Offset 0 49 99 0 24 50 0 20 16QAM 1 0 20 16QAM 1 49 20 16QAM 1 99 20 16QAM 50 0 20 16QAM 50 24 20 16QAM 50 50 20 16QAM 100 0 Channel Frequency (MHz) 15 QPSK 1 0 15 QPSK 1 37 15 QPSK 1 74 15 QPSK 36 0 15 QPSK 36 20 15 QPSK 36 39 15 QPSK 75 0 15 16QAM 1 0 15 16QAM 1 37 15 16QAM 1 74 15 16QAM 36 0 15 16QAM 36 20 15 16QAM 36 39 15 16QAM 75 0 Channel Frequency (MHz) 10 QPSK 1 0 10 QPSK 1 25 10 QPSK 1 49 10 QPSK 25 0 10 QPSK 25 12 10 QPSK 25 25 10 QPSK 50 0 10 16QAM 1 0 10 16QAM 1 25 10 16QAM 1 49 10 16QAM 25 0 10 16QAM 25 12 10 16QAM 25 25 10 16QAM 50 0 Channel Frequency (MHz) Report no.: 2390387R-RF-US-P07V01 Conducted Power(dBm) 18700 1860 22.16 22.39 22.08 21.10 21.14 21.07 21.12 21.60 21.86 21.78 20.24 20.06 20.14 20.06 18675 1857.5 22.07 22.30 22.01 21.01 21.05 21.13 21.01 21.49 21.78 21.67 20.14 20.11 20.02 20.03 18650 1855 22.06 22.30 22.03 21.02 21.04 21.00 21.04 21.53 21.77 21.69 20.13 20.03 20.03 20.13 18625 1852.5 18900 1880 22.17 22.43 22.13 21.14 21.12 21.07 21.09 21.66 21.83 21.71 20.18 20.13 20.22 20.12 18900 1880 22.04 22.30 22.04 21.03 21.00 21.11 21.01 21.55 21.75 21.61 20.10 20.02 20.14 20.02 18900 1880 22.04 22.31 22.05 21.05 21.01 21.01 21.01 21.58 21.72 21.58 20.10 20.01 20.09 20.00 18900 1880 19100 1900 22.26 22.34 22.15 21.17 21.14 21.06 21.21 21.66 21.78 21.80 20.29 20.10 20.22 20.10 19125 1902.5 22.17 22.25 22.03 21.05 21.06 21.11 21.13 21.55 21.68 21.67 20.16 20.02 20.12 20.01 19150 1905 22.15 22.23 22.07 21.09 21.04 21.05 21.13 21.55 21.66 21.68 20.22 20.00 20.11 20.08 19175 1907.5 EIRP (dBm) Verdict 18700 1860 22.8 23.03 22.72 21.74 21.78 21.71 21.76 22.24 22.5 22.42 20.88 20.7 20.78 20.7 18675 1857.5 22.71 22.94 22.65 21.65 21.69 21.77 21.65 22.13 22.42 22.31 20.78 20.75 20.66 20.67 18650 1855 22.7 22.94 22.67 21.66 21.68 21.64 21.68 22.17 22.41 22.33 20.77 20.67 20.67 20.77 18625 1852.5 18900 1880 22.81 23.07 22.77 21.78 21.76 21.71 21.73 22.3 22.47 22.35 20.82 20.77 20.86 20.76 18900 1880 22.68 22.94 22.68 21.67 21.64 21.75 21.65 22.19 22.39 22.25 20.74 20.66 20.78 20.66 18900 1880 22.68 22.95 22.69 21.69 21.65 21.65 21.65 22.22 22.36 22.22 20.74 20.65 20.73 20.64 18900 1880 19100 1900 22.9 22.98 22.79 21.81 21.78 21.7 21.85 Pass Pass Pass Pass Pass Pass Pass 22.3 22.42 22.44 20.93 20.74 20.86 20.74 19125 1902.5 Pass Pass Pass Pass Pass Pass Pass Verdict 22.81 22.89 22.67 21.69 21.7 21.75 21.77 22.19 22.32 Pass Pass Pass Pass Pass Pass Pass Pass Pass 22.31 20.8 20.66 20.76 20.65 19150 1905 22.79 22.87 22.71 21.73 21.68 21.69 21.77 22.19 22.3 22.32 20.86 20.64 20.75 20.72 19175 1907.5 Pass Pass Pass Pass Pass Verdict Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Verdict Page 24 / 95 DEKRA Testing and Certification (Suzhou) Co., Ltd. No.99 Hongye Rd., Suzhou Industrial Park, Suzhou, 215006, Jiangsu, China TEL: +86-512-6251-5088 / FAX: +86-512-6251-5098 5 QPSK 1 0 5 QPSK 1 12 5 QPSK 1 24 5 QPSK 12 0 5 QPSK 12 7 5 QPSK 12 13 5 QPSK 25 0 5 16QAM 1 0 5 16QAM 1 12 5 16QAM 1 24 5 16QAM 12 0 5 16QAM 12 7 5 16QAM 12 13 5 16QAM 25 0 Channel Frequency (MHz) 3 QPSK 1 0 3 QPSK 1 8 3 QPSK 1 14 3 QPSK 8 0 3 QPSK 8 4 3 QPSK 8 7 3 QPSK 15 0 3 16QAM 1 0 3 16QAM 1 8 3 16QAM 1 14 3 16QAM 8 0 3 16QAM 8 4 3 16QAM 8 7 3 16QAM 15 0 Channel Frequency (MHz) 1.4 QPSK 1 0 1.4 QPSK 1 3 1.4 QPSK 1 5 1.4 QPSK 3 0 1.4 QPSK 3 1 1.4 QPSK 3 3 1.4 QPSK 6 0 1.4 16QAM 1 0 1.4 16QAM 1 3 1.4 16QAM 1 5 1.4 16QAM 3 0 1.4 16QAM 3 1 1.4 16QAM 3 3 1.4 16QAM 6 0 22.05 22.32 22.00 21.02 21.02 21.13 21.05 21.50 21.76 21.67 20.15 20.03 20.05 20.11 18615 1851.5 22.06 22.30 22.01 21.11 21.02 21.11 21.00 21.48 21.75 21.69 20.16 20.13 20.04 20.11 18607 1850.7 22.09 22.27 22.00 22.05 22.29 22.03 21.01 21.51 21.73 21.68 21.11 21.03 21.03 20.11 22.10 22.34 22.06 21.05 21.00 21.11 21.00 21.56 21.72 21.59 20.11 20.02 20.13 20.01 18900 1880 22.08 22.35 22.01 21.06 21.05 21.12 21.01 21.55 21.73 21.62 20.07 20.05 20.15 20.01 18900 1880 22.06 22.34 22.01 22.09 22.35 22.00 21.00 21.59 21.72 21.59 21.02 21.00 21.15 20.02 22.17 22.27 22.06 21.06 21.02 21.09 21.08 21.58 21.67 21.69 20.17 20.00 20.09 20.02 19185 1908.5 22.14 22.22 22.08 21.06 21.07 21.09 21.11 21.57 21.69 21.71 20.21 20.02 20.09 20.02 19193 1909.3 22.14 22.22 22.04 22.15 22.27 22.04 21.09 21.57 21.68 21.70 21.08 21.02 21.09 20.11 22.69 22.96 22.64 21.66 21.66 21.77 21.69 22.14 22.4 22.31 20.79 20.67 20.69 20.75 18615 1851.5 22.7 22.94 22.65 21.75 21.66 21.75 21.64 22.12 22.39 22.33 20.8 20.77 20.68 20.75 18607 1850.7 22.73 22.91 22.64 22.69 22.93 22.67 21.65 22.15 22.37 22.32 21.75 21.67 21.67 20.75 22.74 22.98 22.7 21.69 21.64 21.75 21.64 22.2 22.36 22.23 20.75 20.66 20.77 20.65 18900 1880 22.72 22.99 22.65 21.7 21.69 21.76 21.65 22.19 22.37 22.26 20.71 20.69 20.79 20.65 18900 1880 22.7 22.98 22.65 22.73 22.99 22.64 21.64 22.23 22.36 22.23 21.66 21.64 21.79 20.66 22.81 22.91 22.7 21.7 21.66 21.73 21.72 22.22 22.31 22.33 20.81 20.64 20.73 20.66 19185 1908.5 22.78 22.86 22.72 21.7 21.71 21.73 21.75 22.21 22.33 22.35 20.85 20.66 20.73 20.66 19193 1909.3 22.78 22.86 22.68 22.79 22.91 22.68 21.73 22.21 22.32 22.34 21.72 21.66 21.73 20.75 Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Verdict Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Verdict Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Report no.: 2390387R-RF-US-P07V01 Page 25 / 95 DEKRA Testing and Certification (Suzhou) Co., Ltd. No.99 Hongye Rd., Suzhou Industrial Park, Suzhou, 215006, Jiangsu, China TEL: +86-512-6251-5088 / FAX: +86-512-6251-5098 LTE Band4 BW Modulation RB [MHz] Size Channel Frequency (MHz) 20 QPSK 1 20 QPSK 1 20 QPSK 1 20 QPSK 50 20 QPSK 50 20 QPSK 50 20 QPSK 100 RB Offset 0 49 99 0 24 50 0 20 16QAM 20 16QAM 20 16QAM 20 16QAM 20 16QAM 20 16QAM 20 16QAM Channel Frequency (MHz) 1 0 1 49 1 99 50 0 50 24 50 50 100 0 15 QPSK 1 0 15 QPSK 1 37 15 QPSK 1 74 15 QPSK 36 0 15 QPSK 36 20 15 QPSK 36 39 15 QPSK 75 0 15 16QAM 1 0 15 16QAM 1 37 15 16QAM 1 74 15 16QAM 36 0 15 16QAM 36 20 15 16QAM 36 39 15 16QAM 75 0 Channel Frequency (MHz) 10 QPSK 1 0 10 QPSK 1 25 10 QPSK 1 49 10 QPSK 25 0 10 QPSK 25 12 10 QPSK 25 25 10 QPSK 50 0 10 16QAM 1 0 10 16QAM 1 25 10 16QAM 1 49 10 16QAM 25 0 10 16QAM 25 12 10 16QAM 25 25 10 16QAM 50 0 Channel Frequency (MHz) Report no.: 2390387R-RF-US-P07V01 Conducted Power(dBm) 20050 1720 22.30 22.61 22.28 21.27 21.23 21.17 21.25 21.78 22.08 21.99 20.43 20.22 20.31 20.17 20025 1717.5 22.20 22.49 22.18 21.18 21.21 21.16 21.20 21.64 21.95 21.83 20.38 20.20 20.26 20.07 20000 1715 22.25 22.48 22.21 21.11 21.24 21.08 21.17 21.64 21.94 21.82 20.34 20.16 20.27 20.18 19975 1712.5 20175 1732.5 22.29 22.63 22.33 21.31 21.27 21.29 21.20 21.86 22.02 21.88 20.32 20.32 20.41 20.31 20175 1732.5 22.24 22.49 22.22 21.19 21.22 21.08 21.14 21.68 21.86 21.73 20.28 20.13 20.35 20.18 20175 1732.5 22.24 22.51 22.23 21.16 21.17 21.18 21.17 21.66 21.91 21.82 20.25 20.25 20.35 20.14 20175 1732.5 20300 1745 22.48 22.53 22.31 21.33 21.27 21.25 21.35 21.76 21.88 21.93 20.47 20.26 20.42 20.29 20325 1747.5 22.31 22.37 22.16 21.24 21.15 21.14 21.28 21.75 21.82 21.82 20.31 20.17 20.34 20.22 20350 1750 22.38 22.41 22.18 21.30 21.20 21.17 21.21 21.69 21.92 21.86 20.42 20.10 20.24 20.19 20375 1752.5 EIRP (dBm) Verdict 20050 1720 23.14 23.45 23.12 22.11 22.07 22.01 22.09 22.62 22.92 22.83 21.27 21.06 21.15 21.01 20025 1717.5 23.04 23.33 23.02 22.02 22.05 22.00 22.04 22.48 22.79 22.67 21.22 21.04 21.100 20.91 20000 1715 23.09 23.32 23.05 21.95 22.08 21.92 22.01 22.48 22.78 22.66 21.18 21.00 21.11 21.02 19975 1712.5 20175 1732.5 23.13 23.47 23.17 22.15 22.11 22.13 22.04 22.7 22.86 22.72 21.16 21.16 21.25 21.15 20175 1732.5 23.08 23.33 23.06 22.03 22.06 21.92 21.98 22.52 22.7 22.57 21.12 20.97 21.19 21.02 20175 1732.5 23.08 23.35 23.07 22.00 22.01 22.02 22.01 22.5 22.75 22.66 21.09 21.09 21.19 20.98 20175 1732.5 20300 1745 23.32 23.37 23.15 22.17 22.11 22.09 22.19 Pass Pass Pass Pass Pass Pass Pass 22.6 22.72 22.77 21.31 21.1 21.26 21.13 20325 1747.5 Pass Pass Pass Pass Pass Pass Pass Verdict 23.15 23.21 23.00 22.08 21.99 21.98 22.12 22.59 22.66 Pass Pass Pass Pass Pass Pass Pass Pass Pass 22.66 21.15 21.01 21.18 21.06 20350 1750 23.22 23.25 23.02 22.14 22.04 22.01 22.05 22.53 22.76 22.7 21.26 20.94 21.08 21.03 20375 1752.5 Pass Pass Pass Pass Pass Verdict Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Verdict Page 26 / 95 DEKRA Testing and Certification (Suzhou) Co., Ltd. No.99 Hongye Rd., Suzhou Industrial Park, Suzhou, 215006, Jiangsu, China TEL: +86-512-6251-5088 / FAX: +86-512-6251-5098 5 QPSK 1 0 5 QPSK 1 12 5 QPSK 1 24 5 QPSK 12 0 5 QPSK 12 7 5 QPSK 12 13 5 QPSK 25 0 5 16QAM 1 0 5 16QAM 1 12 5 16QAM 1 24 5 16QAM 12 0 5 16QAM 12 7 5 16QAM 12 13 5 16QAM 25 0 Channel Frequency (MHz) 3 QPSK 1 0 3 QPSK 1 8 3 QPSK 1 14 3 QPSK 8 0 3 QPSK 8 4 3 QPSK 8 7 3 QPSK 15 0 3 16QAM 1 0 3 16QAM 1 8 3 16QAM 1 14 3 16QAM 8 0 3 16QAM 8 4 3 16QAM 8 7 3 16QAM 15 0 Channel Frequency (MHz) 1.4 QPSK 1 0 1.4 QPSK 1 3 1.4 QPSK 1 5 1.4 QPSK 3 0 1.4 QPSK 3 1 1.4 QPSK 3 3 1.4 QPSK 6 0 1.4 16QAM 1 0 1.4 16QAM 1 3 1.4 16QAM 1 5 1.4 16QAM 3 0 1.4 16QAM 3 1 1.4 16QAM 3 3 1.4 16QAM 6 0 22.24 22.46 22.16 21.16 21.23 21.17 21.17 21.63 21.93 21.90 20.32 20.13 20.18 20.16 19965 1711.5 22.23 22.41 22.08 21.13 21.19 21.18 21.22 21.61 21.96 21.83 20.30 20.19 20.18 20.11 19957 1710.7 22.27 22.43 22.22 22.16 22.48 22.07 21.17 21.65 21.88 21.89 21.13 21.24 21.20 20.08 22.18 22.51 22.24 21.26 21.23 21.16 21.14 21.68 21.85 21.79 20.20 20.26 20.28 20.25 20175 1732.5 22.20 22.50 22.25 21.17 21.22 21.12 21.10 21.76 21.85 21.72 20.24 20.20 20.28 20.13 20175 1732.5 22.25 22.54 22.13 22.30 22.56 22.23 21.19 21.79 21.82 21.71 21.25 21.13 21.12 20.18 22.30 22.37 22.20 21.26 21.27 21.08 21.27 21.73 21.88 21.91 20.30 20.18 20.23 20.16 20385 1753.5 22.34 22.46 22.23 21.23 21.16 21.18 21.32 21.71 21.89 21.94 20.34 20.20 20.25 20.11 20393 1754.3 22.35 22.40 22.19 22.29 22.44 22.14 21.30 21.73 21.91 21.83 21.25 21.13 21.15 20.13 23.08 23.30 23.00 22.00 22.07 22.01 22.01 22.47 22.77 22.74 21.16 20.97 21.02 21.00 19965 1711.5 23.07 23.25 22.92 21.97 22.03 22.02 22.06 22.45 22.8 22.67 21.14 21.03 21.02 20.95 19957 1710.7 23.11 23.27 23.06 23.00 23.32 22.91 22.01 22.49 22.72 22.73 21.97 22.08 22.04 20.92 23.02 23.35 23.08 22.1 22.07 22.00 21.98 22.52 22.69 22.63 21.04 21.10 21.12 21.09 20175 1732.5 23.04 23.34 23.09 22.01 22.06 21.96 21.94 22.6 22.69 22.56 21.08 21.04 21.12 20.97 20175 1732.5 23.09 23.38 22.97 23.14 23.4 23.07 22.03 22.63 22.66 22.55 22.09 21.97 21.96 21.02 23.14 23.21 23.04 22.10 22.11 21.92 22.11 22.57 22.72 22.75 21.14 21.02 21.07 21.00 20385 1753.5 23.18 23.3 23.07 22.07 22 22.02 22.16 22.55 22.73 22.78 21.18 21.04 21.09 20.95 20393 1754.3 23.19 23.24 23.03 23.13 23.28 22.98 22.14 22.57 22.75 22.67 22.09 21.97 21.99 20.97 Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Verdict Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Verdict Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Report no.: 2390387R-RF-US-P07V01 Page 27 / 95 DEKRA Testing and Certification (Suzhou) Co., Ltd. No.99 Hongye Rd., Suzhou Industrial Park, Suzhou, 215006, Jiangsu, China TEL: +86-512-6251-5088 / FAX: +86-512-6251-5098 LTE Band5 BW Modulation RB [MHz] Size Channel Frequency (MHz) 10 QPSK 1 10 QPSK 1 10 QPSK 1 10 QPSK 25 10 QPSK 25 10 QPSK 25 10 QPSK 50 RB Offset 0 25 49 0 12 25 0 10 16QAM 1 0 10 16QAM 1 25 10 16QAM 1 49 10 16QAM 25 0 10 16QAM 25 12 10 16QAM 25 25 10 16QAM 50 0 Channel Frequency (MHz) 5 QPSK 1 0 5 QPSK 1 12 5 QPSK 1 24 5 QPSK 12 0 5 QPSK 12 7 5 QPSK 12 13 5 QPSK 25 0 5 16QAM 1 0 5 16QAM 1 12 5 16QAM 1 24 5 16QAM 12 0 5 16QAM 12 7 5 16QAM 12 13 5 16QAM 25 0 Channel Frequency (MHz) 3 QPSK 1 0 3 QPSK 1 8 3 QPSK 1 14 3 QPSK 8 0 3 QPSK 8 4 3 QPSK 8 7 3 QPSK 15 0 3 16QAM 1 0 3 16QAM 1 8 3 16QAM 1 14 3 16QAM 8 0 3 16QAM 8 4 3 16QAM 8 7 3 16QAM 15 0 Channel Frequency (MHz) Report no.: 2390387R-RF-US-P07V01 Conducted Power(dBm) 20450 829 23.15 23.03 23.05 22.30 22.21 22.19 22.15 22.20 22.14 22.15 21.22 21.04 21.33 21.02 20425 826.5 23.00 22.94 22.99 22.28 22.18 22.16 22.05 22.27 22.11 22.16 21.08 20.90 21.31 20.91 20415 825.5 23.04 22.95 22.90 22.21 22.15 22.12 22.10 22.24 22.09 22.12 21.14 20.97 21.24 20.94 20407 824.7 20525 836.5 23.22 23.11 23.09 22.37 22.17 22.18 22.21 22.32 22.12 22.10 21.37 21.32 21.29 21.25 20525 836.5 23.09 23.06 22.97 22.35 22.11 22.13 22.16 22.29 22.12 22.08 21.33 21.21 21.15 21.15 20525 836.5 23.19 22.97 23.06 22.28 22.10 22.09 22.15 22.31 22.08 22.15 21.29 21.27 21.19 21.15 20525 836.5 20600 844 23.15 23.15 23.13 22.29 22.17 22.19 22.37 22.20 22.08 22.09 21.45 21.33 21.45 21.22 20625 846.5 23.09 23.13 23.06 22.25 22.03 22.14 22.29 22.18 22.07 22.10 21.35 21.23 21.35 21.18 20635 847.5 23.13 23.03 23.00 22.26 22.09 22.08 22.32 22.17 22.04 22.13 21.37 21.18 21.37 21.09 20643 848.3 ERP (dBm) Verdict 20450 829 19.95 19.83 19.85 19.1 19.01 18.99 18.95 19 18.94 18.95 18.02 17.84 18.13 17.82 20425 826.5 19.8 19.74 19.79 19.08 18.98 18.96 18.85 19.07 18.91 18.96 17.88 17.7 18.11 17.71 20415 825.5 19.84 19.75 19.7 19.01 18.95 18.92 18.9 19.04 18.89 18.92 17.94 17.77 18.04 17.74 20407 824.7 20525 836.5 20.02 19.91 19.89 19.17 18.97 18.98 19.01 19.12 18.92 18.9 18.17 18.12 18.09 18.05 20525 836.5 19.89 19.86 19.77 19.15 18.91 18.93 18.96 19.09 18.92 18.88 18.13 18.01 17.95 17.95 20525 836.5 19.99 19.77 19.86 19.08 18.9 18.89 18.95 19.11 18.88 18.95 18.09 18.07 17.99 17.95 20525 836.5 20600 844 19.95 19.95 19.93 19.09 18.97 18.99 19.17 Pass Pass Pass Pass Pass Pass Pass 19 18.88 18.89 18.25 18.13 18.25 18.02 20625 846.5 Pass Pass Pass Pass Pass Pass Pass Verdict 19.89 19.93 19.86 19.05 18.83 18.94 19.09 18.98 18.87 Pass Pass Pass Pass Pass Pass Pass Pass Pass 18.9 18.15 18.03 18.15 17.98 20635 847.5 19.93 19.83 19.8 19.06 18.89 18.88 19.12 18.97 18.84 18.93 18.17 17.98 18.17 17.89 20643 848.3 Pass Pass Pass Pass Pass Verdict Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Verdict Page 28 / 95 DEKRA Testing and Certification (Suzhou) Co., Ltd. No.99 Hongye Rd., Suzhou Industrial Park, Suzhou, 215006, Jiangsu, China TEL: +86-512-6251-5088 / FAX: +86-512-6251-5098 1.4 QPSK 1 0 1.4 QPSK 1 3 1.4 QPSK 1 5 1.4 QPSK 3 0 1.4 QPSK 3 1 1.4 QPSK 3 3 1.4 QPSK 6 0 1.4 16QAM 1 0 1.4 16QAM 1 3 1.4 16QAM 1 5 1.4 16QAM 3 0 1.4 16QAM 3 1 1.4 16QAM 3 3 1.4 16QAM 6 0 23.14 23.18 23.02 23.02 23.05 22.92 22.00 22.28 22.10 22.13 22.01 22.06 22.04 20.90 23.08 23.03 22.94 23.12 23.01 23.08 22.03 22.26 22.06 22.12 22.13 22.00 21.99 20.99 23.11 23.01 22.95 23.07 23.03 23.02 22.06 22.16 22.10 22.08 22.05 21.97 21.91 20.93 19.94 19.98 19.82 19.82 19.85 19.72 18.8 19.08 18.9 18.93 18.81 18.86 18.84 17.7 19.88 19.83 19.74 19.92 19.81 19.88 18.83 19.06 18.86 18.92 18.93 18.8 18.79 17.79 19.91 19.81 19.75 19.87 19.83 19.82 18.86 18.96 18.9 18.88 18.85 18.77 18.71 17.73 Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Report no.: 2390387R-RF-US-P07V01 Page 29 / 95 DEKRA Testing and Certification (Suzhou) Co., Ltd. No.99 Hongye Rd., Suzhou Industrial Park, Suzhou, 215006, Jiangsu, China TEL: +86-512-6251-5088 / FAX: +86-512-6251-5098 LTE Band12 BW Modulation RB [MHz] Size Channel Frequency (MHz) 10 QPSK 1 10 QPSK 1 10 QPSK 1 10 QPSK 25 10 QPSK 25 10 QPSK 25 10 QPSK 50 RB Offset 0 25 49 0 12 25 0 10 16QAM 1 0 10 16QAM 1 25 10 16QAM 1 49 10 16QAM 25 0 10 16QAM 25 12 10 16QAM 25 25 10 16QAM 50 0 Channel Frequency (MHz) 5 QPSK 1 0 5 QPSK 1 12 5 QPSK 1 24 5 QPSK 12 0 5 QPSK 12 7 5 QPSK 12 13 5 QPSK 25 0 5 16QAM 1 0 5 16QAM 1 12 5 16QAM 1 24 5 16QAM 12 0 5 16QAM 12 7 5 16QAM 12 13 5 16QAM 25 0 Channel Frequency (MHz) 3 QPSK 1 0 3 QPSK 1 8 3 QPSK 1 14 3 QPSK 8 0 3 QPSK 8 4 3 QPSK 8 7 3 QPSK 15 0 3 16QAM 1 0 3 16QAM 1 8 3 16QAM 1 14 3 16QAM 8 0 3 16QAM 8 4 3 16QAM 8 7 3 16QAM 15 0 Channel Frequency (MHz) Report no.: 2390387R-RF-US-P07V01 Conducted Power(dBm) 23060 704 23.08 22.93 22.97 22.24 22.13 22.13 22.05 22.22 22.11 22.10 21.16 20.96 21.26 20.96 23035 701.5 23.03 22.92 22.93 22.15 22.06 22.05 22.03 22.19 22.11 22.09 21.09 20.91 21.22 20.89 23025 700.5 23.01 22.89 22.90 22.18 22.10 22.07 22.01 22.21 22.12 22.09 21.09 20.90 21.19 20.89 23017 699.7 23095 707.5 23.15 23.05 23.00 22.28 22.10 22.12 22.14 22.23 22.08 22.10 21.28 21.22 21.21 21.18 23095 707.5 23.07 22.98 22.95 22.23 22.02 22.07 22.08 22.27 22.07 22.08 21.23 21.19 21.18 21.14 23095 707.5 23.11 22.96 22.95 22.22 22.04 22.06 22.10 22.23 22.08 22.10 21.25 21.19 21.15 21.11 23095 707.5 23130 711 23.09 23.07 23.05 22.20 22.08 22.11 22.29 22.18 22.04 22.07 21.39 21.23 21.37 21.13 23155 713.5 23.04 23.04 23.01 22.17 22.04 22.06 22.25 22.17 22.03 22.09 21.31 21.18 21.33 21.09 23165 714.5 23.01 23.03 23.02 22.15 22.04 22.06 22.25 22.16 22.03 22.09 21.31 21.20 21.32 21.11 23173 715.3 ERP (dBm) Verdict 23060 704 16.57 16.42 16.46 15.73 15.62 15.62 15.54 15.71 15.6 15.59 14.65 14.45 14.75 14.45 23035 701.5 16.52 16.41 16.42 15.64 15.55 15.54 15.52 15.68 15.6 15.58 14.58 14.4 14.71 14.38 23025 700.5 16.5 16.38 16.39 15.67 15.59 15.56 15.5 15.7 15.61 15.58 14.58 14.39 14.68 14.38 23017 699.7 23095 707.5 16.64 16.54 16.49 15.77 15.59 15.61 15.63 15.72 15.57 15.59 14.77 14.71 14.7 14.67 23095 707.5 16.56 16.47 16.44 15.72 15.51 15.56 15.57 15.76 15.56 15.57 14.72 14.68 14.67 14.63 23095 707.5 16.6 16.45 16.44 15.71 15.53 15.55 15.59 15.72 15.57 15.59 14.74 14.68 14.64 14.6 23095 707.5 23130 711 16.58 16.56 16.54 15.69 15.57 15.6 15.78 Pass Pass Pass Pass Pass Pass Pass 15.67 15.53 15.56 14.88 14.72 14.86 14.62 23155 713.5 Pass Pass Pass Pass Pass Pass Pass Verdict 16.53 16.53 16.5 15.66 15.53 15.55 15.74 15.66 15.52 Pass Pass Pass Pass Pass Pass Pass Pass Pass 15.58 14.8 14.67 14.82 14.58 23165 714.5 16.5 16.52 16.51 15.64 15.53 15.55 15.74 15.65 15.52 15.58 14.8 14.69 14.81 14.6 23173 715.3 Pass Pass Pass Pass Pass Verdict Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Verdict Page 30 / 95 DEKRA Testing and Certification (Suzhou) Co., Ltd. No.99 Hongye Rd., Suzhou Industrial Park, Suzhou, 215006, Jiangsu, China TEL: +86-512-6251-5088 / FAX: +86-512-6251-5098 1.4 QPSK 1 0 1.4 QPSK 1 3 1.4 QPSK 1 5 1.4 QPSK 3 0 1.4 QPSK 3 1 1.4 QPSK 3 3 1.4 QPSK 6 0 1.4 16QAM 1 0 1.4 16QAM 1 3 1.4 16QAM 1 5 1.4 16QAM 3 0 1.4 16QAM 3 1 1.4 16QAM 3 3 1.4 16QAM 6 0 22.96 23.00 22.86 22.85 22.86 22.73 21.82 22.21 22.27 22.10 22.11 21.88 21.87 20.71 22.90 22.85 22.75 22.94 22.84 22.89 21.86 22.37 22.27 22.11 22.17 21.84 21.81 20.81 22.92 22.84 22.78 22.91 22.84 22.85 21.87 22.38 22.17 22.12 22.07 21.78 21.75 20.74 16.45 16.49 16.35 16.34 16.35 16.22 15.31 15.7 15.76 15.59 15.6 15.37 15.36 14.2 16.39 16.34 16.24 16.43 16.33 16.38 15.35 15.86 15.76 15.6 15.66 15.33 15.3 14.3 16.41 16.33 16.27 16.4 16.33 16.34 15.36 15.87 15.66 15.61 15.56 15.27 15.24 14.23 Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass LTE Band13 BW Modulation RB [MHz] Size Channel Frequency (MHz) 10 QPSK 1 10 QPSK 1 10 QPSK 1 10 QPSK 25 10 QPSK 25 10 QPSK 25 10 QPSK 50 10 16QAM 1 10 16QAM 1 10 16QAM 1 10 16QAM 25 10 16QAM 25 10 16QAM 25 10 16QAM 50 Channel Frequency (MHz) 5 QPSK 1 5 QPSK 1 5 QPSK 1 5 QPSK 12 5 QPSK 12 5 QPSK 12 5 QPSK 25 5 16QAM 1 5 16QAM 1 5 16QAM 1 5 16QAM 12 5 16QAM 12 5 16QAM 12 5 16QAM 25 RB Offset 0 25 49 0 12 25 0 0 25 49 0 12 25 0 0 12 24 0 7 13 0 0 12 24 0 7 13 0 Conducted Power(dBm) 23230 782 23.24 23.10 23.06 22.33 22.18 22.20 22.21 22.27 22.06 22.10 21.33 21.27 21.28 21.24 23205 23230 779.5 782 22.98 23.04 22.90 22.96 22.91 22.92 22.12 22.20 22.05 22.01 22.00 22.05 21.99 22.06 22.28 22.25 22.09 22.12 22.16 22.11 21.07 21.18 20.88 21.18 21.19 21.15 20.87 21.09 23255 784.5 23.02 23.01 22.96 22.12 21.99 22.03 22.21 22.15 22.09 22.09 21.27 21.15 21.29 21.06 ERP (dBm) Verdict 23230 782 18.65 18.51 18.47 17.74 17.59 17.61 17.62 17.68 17.47 17.51 16.74 16.68 16.69 16.65 23205 779.5 18.39 18.31 18.32 17.53 17.46 17.41 17.4 17.69 17.5 17.57 16.48 16.29 16.6 16.28 23230 782 18.45 18.37 18.33 17.61 17.42 17.46 17.47 17.66 17.53 17.52 16.59 16.59 16.56 16.5 23255 784.5 18.43 18.42 18.37 17.53 17.4 17.44 17.62 17.56 17.5 17.5 16.68 16.56 16.7 16.47 Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Verdict Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Report no.: 2390387R-RF-US-P07V01 Page 31 / 95 DEKRA Testing and Certification (Suzhou) Co., Ltd. No.99 Hongye Rd., Suzhou Industrial Park, Suzhou, 215006, Jiangsu, China TEL: +86-512-6251-5088 / FAX: +86-512-6251-5098 LTE Band17 BW Modulation RB [MHz] Size Channel Frequency (MHz) 10 QPSK 1 10 QPSK 1 10 QPSK 1 10 QPSK 25 10 QPSK 25 10 QPSK 25 10 QPSK 50 10 16QAM 1 10 16QAM 1 10 16QAM 1 10 16QAM 25 10 16QAM 25 10 16QAM 25 10 16QAM 50 Channel Frequency (MHz) 5 QPSK 1 5 QPSK 1 5 QPSK 1 5 QPSK 12 5 QPSK 12 5 QPSK 12 5 QPSK 25 5 16QAM 1 5 16QAM 1 5 16QAM 1 5 16QAM 12 5 16QAM 12 5 16QAM 12 5 16QAM 25 RB Offset 0 25 49 0 12 25 0 0 25 49 0 12 25 0 0 12 24 0 7 13 0 0 12 24 0 7 13 0 Conducted Power(dBm) 23780 709 23.26 23.09 23.14 22.40 22.30 22.29 22.22 22.23 22.18 22.12 21.33 21.14 21.44 21.13 23755 706.5 23.16 22.93 23.02 22.33 22.16 22.22 22.15 22.16 22.06 22.02 21.22 21.08 21.30 21.04 23790 710 23.34 23.22 23.15 22.46 22.26 22.29 22.29 22.24 22.12 22.12 21.46 21.40 21.37 21.34 23790 710 23.28 23.15 23.02 22.32 22.17 22.17 22.20 22.09 21.98 22.05 21.39 21.24 21.24 21.24 23800 711 23.25 23.24 23.22 22.37 22.26 22.30 22.47 22.19 22.10 22.08 21.56 21.40 21.53 21.30 23825 713.5 23.15 23.13 23.13 22.21 22.16 22.18 22.41 22.10 21.96 21.92 21.50 21.27 21.43 21.18 ERP (dBm) Verdict 23780 709 14.6 14.43 14.48 13.74 13.64 13.63 13.56 13.57 13.52 13.46 12.67 12.48 12.78 12.47 23755 706.5 14.5 14.27 14.36 13.67 13.5 13.56 13.49 13.5 13.4 13.36 12.56 12.42 12.64 12.38 23790 710 14.68 14.56 14.49 13.8 13.6 13.63 13.63 13.58 13.46 13.46 12.8 12.74 12.71 12.68 23790 710 14.62 14.49 14.36 13.66 13.51 13.51 13.54 13.43 13.32 13.39 12.73 12.58 12.58 12.58 23800 711 14.59 14.58 14.56 13.71 13.6 13.64 13.81 13.53 13.44 13.42 12.9 12.74 12.87 12.64 23825 713.5 14.49 14.47 14.47 13.55 13.5 13.52 13.75 13.44 13.3 13.26 12.84 12.61 12.77 12.52 Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Verdict Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Report no.: 2390387R-RF-US-P07V01 Page 32 / 95 DEKRA Testing and Certification (Suzhou) Co., Ltd. No.99 Hongye Rd., Suzhou Industrial Park, Suzhou, 215006, Jiangsu, China TEL: +86-512-6251-5088 / FAX: +86-512-6251-5098 LTE Band25 BW Modulation RB [MHz] Size Channel Frequency (MHz) 20 QPSK 1 20 QPSK 1 20 QPSK 1 20 QPSK 50 20 QPSK 50 20 QPSK 50 20 QPSK 100 20 16QAM 1 20 16QAM 1 20 16QAM 1 20 16QAM 50 20 16QAM 50 20 16QAM 50 20 16QAM 100 Channel Frequency (MHz) 15 QPSK 1 15 QPSK 1 15 QPSK 1 15 QPSK 36 15 QPSK 36 15 QPSK 36 15 QPSK 75 15 16QAM 1 15 16QAM 1 15 16QAM 1 15 16QAM 36 15 16QAM 36 15 16QAM 36 15 16QAM 75 Channel Frequency (MHz) 10 QPSK 1 10 QPSK 1 10 QPSK 1 10 QPSK 25 10 QPSK 25 10 QPSK 25 10 QPSK 50 10 16QAM 1 10 16QAM 1 10 16QAM 1 10 16QAM 25 10 16QAM 25 10 16QAM 25 10 16QAM 50 RB Offset 0 49 99 0 24 50 0 0 49 99 0 24 50 0 0 37 74 0 20 39 0 0 37 74 0 20 39 0 0 25 49 0 12 25 0 0 25 49 0 12 25 0 Conducted Power(dBm) 26140 1860 22.43 22.37 22.24 21.28 21.31 21.23 21.29 21.74 22.08 22.00 20.42 20.19 20.32 20.19 26115 1857.5 22.21 22.22 22.19 21.17 21.26 21.17 21.18 21.71 21.95 21.83 20.35 20.13 20.24 20.17 26090 1855 22.22 22.15 22.14 21.17 21.25 21.22 21.21 21.68 22.01 21.90 20.39 20.19 20.24 20.14 26365 1882.5 22.55 22.42 22.26 21.33 21.25 21.21 21.26 21.79 21.95 21.91 20.39 20.33 20.35 20.27 26365 1882.5 22.29 22.23 22.19 21.23 21.22 21.18 21.21 21.79 21.91 21.83 20.27 20.23 20.32 20.25 26365 1882.5 22.28 22.20 22.23 21.26 21.22 21.17 21.24 21.81 21.91 21.80 20.32 20.23 20.36 20.27 26590 1905 22.44 22.39 22.31 21.38 21.29 21.25 21.38 21.86 21.95 21.94 20.41 20.23 20.37 20.23 26615 1907.5 22.37 22.27 22.23 21.23 21.24 21.19 21.26 21.78 21.86 21.90 20.41 20.17 20.29 20.17 26640 1910 22.34 22.28 22.25 21.29 21.28 21.21 21.29 21.77 21.86 21.86 20.38 20.21 20.34 20.20 EIRP (dBm) Verdict 26140 1860 23.07 23.01 22.88 21.92 21.95 21.87 21.93 22.38 22.72 22.64 21.06 20.83 20.96 20.83 26115 1857.5 22.85 22.86 22.83 21.81 21.9 21.81 21.82 22.35 22.59 22.47 20.99 20.77 20.88 20.81 26090 1855 22.86 22.79 22.78 21.81 21.89 21.86 21.85 22.32 22.65 22.54 21.03 20.83 20.88 20.78 26365 1882.5 23.19 23.06 22.9 21.97 21.89 21.85 21.9 22.43 22.59 22.55 21.03 20.97 20.99 20.91 26365 1882.5 22.93 22.87 22.83 21.87 21.86 21.82 21.85 22.43 22.55 22.47 20.91 20.87 20.96 20.89 26365 1882.5 22.92 22.84 22.87 21.9 21.86 21.81 21.88 22.45 22.55 22.44 20.96 20.87 21 20.91 26590 1905 23.08 23.03 22.95 22.02 21.93 21.89 22.02 22.5 22.59 22.58 21.05 20.87 21.01 20.87 26615 1907.5 23.01 22.91 22.87 21.87 21.88 21.83 21.9 22.42 22.5 22.54 21.05 20.81 20.93 20.81 26640 1910 22.98 22.92 22.89 21.93 21.92 21.85 21.93 22.41 22.5 22.5 21.02 20.85 20.98 20.84 Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Verdict Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Verdict Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Report no.: 2390387R-RF-US-P07V01 Page 33 / 95 DEKRA Testing and Certification (Suzhou) Co., Ltd. No.99 Hongye Rd., Suzhou Industrial Park, Suzhou, 215006, Jiangsu, China TEL: +86-512-6251-5088 / FAX: +86-512-6251-5098 Channel 26065 26365 26665 26065 26365 26665 Verdict Frequency (MHz) 1852.5 1882.5 1912.5 1852.5 1882.5 1912.5 5 QPSK 1 0 22.29 22.28 22.41 22.93 22.92 23.05 Pass 5 QPSK 1 12 22.21 22.18 22.26 22.85 22.82 22.9 Pass 5 QPSK 1 24 22.20 22.25 22.21 22.84 22.89 22.85 Pass 5 QPSK 12 0 21.23 21.20 21.27 21.87 21.84 21.91 Pass 5 QPSK 12 7 21.20 21.21 21.20 21.84 21.85 21.84 Pass 5 QPSK 12 13 21.18 21.14 21.16 21.82 21.78 21.8 Pass 5 QPSK 25 0 21.25 21.15 21.30 21.89 21.79 21.94 Pass 5 16QAM 1 0 21.72 21.80 21.81 22.36 22.44 22.45 Pass 5 16QAM 1 12 21.95 21.93 21.88 22.59 22.57 22.52 Pass 5 16QAM 1 24 21.84 21.79 21.86 22.48 22.43 22.5 Pass 5 16QAM 12 0 20.32 20.25 20.36 20.96 20.89 21 Pass 5 16QAM 12 7 20.17 20.21 20.23 20.81 20.85 20.87 Pass 5 16QAM 12 13 20.21 20.33 20.31 20.85 20.97 20.95 Pass 5 16QAM 25 0 20.14 20.19 20.18 20.78 20.83 20.82 Pass Channel 26055 26365 26675 26055 26365 26675 Verdict Frequency (MHz) 1851.5 1882.5 1913.5 1851.5 1882.5 1913.5 3 QPSK 1 0 22.28 22.29 22.34 22.92 22.93 22.98 Pass 3 QPSK 1 8 22.20 22.22 22.23 22.84 22.86 22.87 Pass 3 QPSK 1 14 22.22 22.27 22.24 22.86 22.91 22.88 Pass 3 QPSK 8 0 21.20 21.24 21.28 21.84 21.88 21.92 Pass 3 QPSK 8 4 21.20 21.22 21.26 21.84 21.86 21.9 Pass 3 QPSK 8 7 21.19 21.21 21.13 21.83 21.85 21.77 Pass 3 QPSK 15 0 21.25 21.20 21.28 21.89 21.84 21.92 Pass 3 16QAM 1 0 21.74 21.73 21.77 22.38 22.37 22.41 Pass 3 16QAM 1 8 21.99 21.92 21.93 22.63 22.56 22.57 Pass 3 16QAM 1 14 21.85 21.82 21.95 22.49 22.46 22.59 Pass 3 16QAM 8 0 20.38 20.26 20.39 21.02 20.9 21.03 Pass 3 16QAM 8 4 20.20 20.23 20.21 20.84 20.87 20.85 Pass 3 16QAM 8 7 20.20 20.33 20.28 20.84 20.97 20.92 Pass 3 16QAM 15 0 20.19 20.20 20.20 20.83 20.84 20.84 Pass Channel 26047 26365 26683 26047 26365 26683 Verdict Frequency (MHz) 1850.7 1882.5 1914.3 1850.7 1882.5 1914.3 1.4 QPSK 1 0 22.28 22.24 22.30 22.92 22.88 22.94 Pass 1.4 QPSK 1 3 22.21 22.17 22.30 22.85 22.81 22.94 Pass 1.4 QPSK 1 5 22.16 22.12 22.17 22.8 22.76 22.81 Pass 1.4 QPSK 3 0 22.23 22.27 22.33 22.87 22.91 22.97 Pass 1.4 QPSK 3 1 22.41 22.50 22.41 23.05 23.14 23.05 Pass 1.4 QPSK 3 3 22.06 22.15 22.23 22.7 22.79 22.87 Pass 1.4 QPSK 6 0 21.13 21.14 21.24 21.77 21.78 21.88 Pass 1.4 16QAM 1 0 21.68 21.79 21.74 22.32 22.43 22.38 Pass 1.4 16QAM 1 3 21.85 21.90 21.86 22.49 22.54 22.5 Pass 1.4 16QAM 1 5 21.88 21.77 21.90 22.52 22.41 22.54 Pass 1.4 16QAM 3 0 21.18 21.16 21.24 21.82 21.8 21.88 Pass 1.4 16QAM 3 1 21.16 21.15 21.13 21.8 21.79 21.77 Pass 1.4 16QAM 3 3 21.11 21.08 21.09 21.75 21.72 21.73 Pass 1.4 16QAM 6 0 20.10 20.14 20.17 20.74 20.78 20.81 Pass Report no.: 2390387R-RF-US-P07V01 Page 34 / 95 DEKRA Testing and Certification (Suzhou) Co., Ltd. No.99 Hongye Rd., Suzhou Industrial Park, Suzhou, 215006, Jiangsu, China TEL: +86-512-6251-5088 / FAX: +86-512-6251-5098 LTE Band26 BW Modulation RB [MHz] Size Channel RB Offset Frequency (MHz) 15 QPSK 1 0 15 QPSK 1 37 15 QPSK 1 74 15 QPSK 36 0 15 QPSK 36 20 15 QPSK 36 39 15 QPSK 75 0 15 16QAM 1 0 15 16QAM 1 37 15 16QAM 1 74 15 16QAM 36 0 15 16QAM 36 20 15 16QAM 36 39 15 16QAM 75 0 Channel Frequency (MHz) 10 QPSK 1 0 10 QPSK 1 25 10 QPSK 1 49 10 QPSK 25 0 10 QPSK 25 12 10 QPSK 25 25 10 QPSK 50 0 10 16QAM 1 0 10 16QAM 1 25 10 16QAM 1 49 10 16QAM 25 0 10 16QAM 25 12 10 16QAM 25 25 10 16QAM 50 0 Channel Frequency (MHz) 5 QPSK 1 0 5 QPSK 1 12 5 QPSK 1 24 5 QPSK 12 0 5 QPSK 12 7 5 QPSK 12 13 5 QPSK 25 0 5 16QAM 1 0 5 16QAM 1 12 5 16QAM 1 24 5 16QAM 12 0 5 16QAM 12 7 5 16QAM 12 13 Report no.: 2390387R-RF-US-P07V01 Conducted Power(dBm) 26765 821.5 23.16 23.06 23.06 22.33 22.22 22.20 22.18 22.34 22.22 22.22 21.23 21.06 21.34 21.05 26740 819 23.02 22.93 22.94 22.18 22.08 22.08 22.04 22.21 22.08 22.09 21.08 20.92 21.19 20.91 26715 816.5 23.03 22.92 22.91 22.19 22.07 22.08 22.05 22.20 22.08 22.09 21.11 20.93 21.21 26865 831.5 23.24 23.13 23.11 22.38 22.17 22.19 22.24 22.39 22.19 22.21 21.39 21.33 21.32 21.26 26865 831.5 23.10 23.00 22.97 22.23 22.03 22.06 22.12 22.26 22.05 22.08 21.25 21.19 21.18 21.14 26865 831.5 23.12 22.99 22.98 22.24 22.04 22.05 22.10 22.25 22.04 22.09 21.25 21.20 21.19 2696 5 841.5 23.18 23.16 23.13 22.29 22.17 22.21 22.38 22.29 22.17 22.23 21.47 21.33 21.46 21.24 2699 0 844 23.04 23.01 22.98 22.17 22.03 22.06 22.26 22.17 22.04 22.11 21.33 21.20 21.31 21.09 2701 5 846.5 23.06 23.01 23.00 22.16 22.04 22.08 22.24 22.16 22.03 22.11 21.32 21.20 21.33 26765 821.5 20.61 20.51 20.51 19.78 19.67 19.65 19.63 19.79 19.67 19.67 18.68 18.51 18.79 18.5 26740 819 20.47 20.38 20.39 19.63 19.53 19.53 19.49 19.66 19.53 19.54 18.53 18.37 18.64 18.36 26715 816.5 20.48 20.37 20.36 19.64 19.52 19.53 19.5 19.65 19.53 19.54 18.56 18.38 18.66 ERP (dBm) Verdict 26865 26965 831.5 20.69 20.58 20.56 19.83 19.62 19.64 19.69 19.84 19.64 19.66 18.84 18.78 18.77 18.71 26865 841.5 20.63 20.61 20.58 19.74 19.62 19.66 19.83 19.74 19.62 19.68 18.92 18.78 18.91 18.69 26990 Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Verdict 831.5 844 20.55 20.49 20.45 20.46 20.42 20.43 19.68 19.62 19.48 19.48 19.51 19.51 19.57 19.71 19.71 19.62 19.5 19.49 19.53 19.56 18.7 18.78 18.64 18.65 18.63 18.76 18.59 18.54 26865 27015 Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Verdict 831.5 20.57 20.44 20.43 19.69 19.49 19.5 19.55 19.7 19.49 19.54 18.7 18.65 18.64 846.5 20.51 20.46 20.45 19.61 19.49 19.53 19.69 19.61 19.48 19.56 18.77 18.65 18.78 Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Page 35 / 95 DEKRA Testing and Certification (Suzhou) Co., Ltd. No.99 Hongye Rd., Suzhou Industrial Park, Suzhou, 215006, Jiangsu, China TEL: +86-512-6251-5088 / FAX: +86-512-6251-5098 5 16QAM 25 0 20.92 21.12 21.10 18.37 18.57 18.55 Pass Channel 26705 26865 27025 26705 26865 27025 Verdict Frequency (MHz) 815.5 831.5 847.5 815.5 831.5 847.5 3 QPSK 1 0 23.01 23.09 23.05 20.46 20.54 20.5 Pass 3 QPSK 1 8 22.93 23.00 23.03 20.38 20.45 20.48 Pass 3 QPSK 1 14 22.91 22.96 22.99 20.36 20.41 20.44 Pass 3 QPSK 8 0 22.19 22.24 22.17 19.64 19.69 19.62 Pass 3 QPSK 8 4 22.09 22.03 22.03 19.54 19.48 19.48 Pass 3 QPSK 8 7 22.05 22.05 22.09 19.5 19.5 19.54 Pass 3 QPSK 15 0 22.03 22.11 22.23 19.48 19.56 19.68 Pass 3 16QAM 1 0 22.22 22.25 22.17 19.67 19.7 19.62 Pass 3 16QAM 1 8 22.09 22.06 22.05 19.54 19.51 19.5 Pass 3 16QAM 1 14 22.09 22.07 22.09 19.54 19.52 19.54 Pass 3 16QAM 8 0 21.09 21.26 21.34 18.54 18.71 18.79 Pass 3 16QAM 8 4 20.91 21.20 21.19 18.36 18.65 18.64 Pass 3 16QAM 8 7 21.21 21.19 21.32 18.66 18.64 18.77 Pass 3 16QAM 15 0 20.92 21.12 21.09 18.37 18.57 18.54 Pass Channel 26697 26865 27033 26697 26865 27033 Verdict Frequency (MHz) 814.7 831.5 848.3 814.7 831.5 848.3 1.4 QPSK 1 0 23.15 23.05 23.07 20.6 20.5 20.52 Pass 1.4 QPSK 1 3 23.17 23.00 22.98 20.62 20.45 20.43 Pass 1.4 QPSK 1 5 23.02 22.95 22.96 20.47 20.4 20.41 Pass 1.4 QPSK 3 0 23.07 23.17 23.06 20.52 20.62 20.51 Pass 1.4 QPSK 3 1 23.03 23.03 22.99 20.48 20.48 20.44 Pass 1.4 QPSK 3 3 22.87 23.12 22.98 20.32 20.57 20.43 Pass 1.4 QPSK 6 0 21.96 22.08 22.08 19.41 19.53 19.53 Pass 1.4 16QAM 1 0 22.44 22.51 22.61 19.89 19.96 20.06 Pass 1.4 16QAM 1 3 22.62 22.59 22.74 20.07 20.04 20.19 Pass 1.4 16QAM 1 5 22.66 22.52 22.61 20.11 19.97 20.06 Pass 1.4 16QAM 3 0 22.02 22.17 22.07 19.47 19.62 19.52 Pass 1.4 16QAM 3 1 22.02 22.00 22.01 19.47 19.45 19.46 Pass 1.4 16QAM 3 3 22.01 21.98 21.89 19.46 19.43 19.34 Pass 1.4 16QAM 6 0 20.86 21.05 20.92 18.31 18.5 18.37 Pass Report no.: 2390387R-RF-US-P07V01 Page 36 / 95 DEKRA Testing and Certification (Suzhou) Co., Ltd. No.99 Hongye Rd., Suzhou Industrial Park, Suzhou, 215006, Jiangsu, China TEL: +86-512-6251-5088 / FAX: +86-512-6251-5098 LTE Band41 BW Modulation RB [MHz] Size Channel Frequency (MHz) 20 QPSK 1 20 QPSK 1 20 QPSK 1 20 QPSK 50 20 QPSK 50 20 QPSK 50 20 QPSK 100 20 16QAM 1 20 16QAM 1 20 16QAM 1 20 16QAM 50 20 16QAM 50 20 16QAM 50 20 16QAM 100 Channel Frequency (MHz) 15 QPSK 1 15 QPSK 1 15 QPSK 1 15 QPSK 36 15 QPSK 36 15 QPSK 36 15 QPSK 75 15 16QAM 1 15 16QAM 1 15 16QAM 1 15 16QAM 36 15 16QAM 36 15 16QAM 36 15 16QAM 75 Channel Frequency (MHz) 10 QPSK 1 10 QPSK 1 10 QPSK 1 10 QPSK 25 10 QPSK 25 10 QPSK 25 10 QPSK 50 10 16QAM 1 10 16QAM 1 10 16QAM 1 10 16QAM 25 10 16QAM 25 10 16QAM 25 10 16QAM 50 RB Offset 0 49 99 0 24 50 0 0 49 99 0 24 50 0 0 37 74 0 20 39 0 0 37 74 0 20 39 0 0 25 49 0 12 25 0 0 25 49 0 12 25 0 Conducted Power(dBm) 40340 2565 22.53 22.25 22.25 21.24 21.32 21.21 21.24 21.76 22.03 21.88 20.42 20.17 20.33 20.21 40315 2562.5 22.41 22.12 22.05 21.14 21.17 21.02 21.12 21.60 21.89 21.74 20.28 20.06 20.12 20.06 40290 2560 22.36 22.07 22.07 21.15 21.18 21.03 21.08 21.58 21.86 21.83 20.26 20.07 20.17 20.04 40740 2605 22.62 22.28 22.28 21.31 21.31 21.18 21.36 21.84 21.94 21.95 20.47 20.24 20.34 20.25 40740 2605 22.35 22.12 22.20 21.20 21.10 21.05 21.24 21.66 21.78 21.80 20.30 20.10 20.26 20.09 40740 2605 22.32 22.16 22.15 21.17 21.14 21.07 21.21 21.64 21.81 21.82 20.33 20.09 20.27 20.09 41140 2645 22.50 22.28 22.26 21.32 21.29 21.24 21.32 21.79 21.94 21.98 20.39 20.21 20.33 20.24 41165 2647.5 22.35 22.16 22.19 21.13 21.14 21.09 21.23 21.71 21.77 21.78 20.26 20.10 20.26 20.08 41190 2650 22.38 22.11 22.19 21.14 21.17 21.06 21.25 21.69 21.78 21.85 20.24 20.13 20.18 20.08 EIRP (dBm) Verdict 40340 2565 25.37 25.09 25.09 24.08 24.16 24.05 24.08 24.6 24.87 24.72 23.26 23.01 23.17 23.05 40315 2562.5 25.25 24.96 24.89 23.98 24.01 23.86 23.96 24.44 24.73 24.58 23.12 22.9 22.96 22.9 40290 2560 25.2 24.91 24.91 23.99 24.02 23.87 23.92 24.42 24.7 24.67 23.1 22.91 23.01 22.88 40740 2605 25.46 25.12 25.12 24.15 24.15 24.02 24.2 24.68 24.78 24.79 23.31 23.08 23.18 23.09 40740 2605 25.19 24.96 25.04 24.04 23.94 23.89 24.08 24.5 24.62 24.64 23.14 22.94 23.1 22.93 40740 2605 25.16 25 24.99 24.01 23.98 23.91 24.05 24.48 24.65 24.66 23.17 22.93 23.11 22.93 41140 2645 25.34 25.12 25.1 24.16 24.13 24.08 24.16 24.63 24.78 24.82 23.23 23.05 23.17 23.08 41165 2647.5 25.19 25 25.03 23.97 23.98 23.93 24.07 24.55 24.61 24.62 23.1 22.94 23.1 22.92 41190 2650 25.22 24.95 25.03 23.98 24.01 23.9 24.09 24.53 24.62 24.69 23.08 22.97 23.02 22.92 Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Verdict Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Verdict Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Report no.: 2390387R-RF-US-P07V01 Page 37 / 95 DEKRA Testing and Certification (Suzhou) Co., Ltd. No.99 Hongye Rd., Suzhou Industrial Park, Suzhou, 215006, Jiangsu, China TEL: +86-512-6251-5088 / FAX: +86-512-6251-5098 Channel 40265 40740 41215 40265 40740 41215 Verdict Frequency (MHz) 2557.5 2605 2652.5 2557.5 2605 2652.5 5 QPSK 1 0 22.36 22.39 22.34 25.2 25.23 25.18 Pass 5 QPSK 1 12 22.11 22.17 22.14 24.95 25.01 24.98 Pass 5 QPSK 1 24 22.06 22.14 22.13 24.9 24.98 24.97 Pass 5 QPSK 12 0 21.12 21.13 21.18 23.96 23.97 24.02 Pass 5 QPSK 12 7 21.17 21.16 21.16 24.01 24 24 Pass 5 QPSK 12 13 21.10 21.10 21.05 23.94 23.94 23.89 Pass 5 QPSK 25 0 21.13 21.21 21.17 23.97 24.05 24.01 Pass 5 16QAM 1 0 21.58 21.61 21.65 24.42 24.45 24.49 Pass 5 16QAM 1 12 21.88 21.73 21.81 24.72 24.57 24.65 Pass 5 16QAM 1 24 21.75 21.81 21.81 24.59 24.65 24.65 Pass 5 16QAM 12 0 20.19 20.26 20.31 23.03 23.1 23.15 Pass 5 16QAM 12 7 20.08 20.11 20.09 22.92 22.95 22.93 Pass 5 16QAM 12 13 20.11 20.19 20.20 22.95 23.03 23.04 Pass 5 16QAM 25 0 20.11 20.09 20.14 22.95 22.93 22.98 Pass Report no.: 2390387R-RF-US-P07V01 Page 38 / 95 DEKRA Testing and Certification (Suzhou) Co., Ltd. No.99 Hongye Rd., Suzhou Industrial Park, Suzhou, 215006, Jiangsu, China TEL: +86-512-6251-5088 / FAX: +86-512-6251-5098 LTE Band26 - IC BW Modulation [MHz] Channel Frequency (MHz) 15 QPSK 15 QPSK 15 QPSK 15 QPSK 15 QPSK 15 QPSK 15 QPSK 15 16QAM 15 16QAM 15 16QAM 15 16QAM 15 16QAM 15 16QAM 15 16QAM Channel Frequency (MHz) 10 QPSK 10 QPSK 10 QPSK 10 QPSK 10 QPSK 10 QPSK 10 QPSK 10 16QAM 10 16QAM 10 16QAM 10 16QAM 10 16QAM 10 16QAM 10 16QAM Channel Frequency (MHz) 5 QPSK 5 QPSK 5 QPSK 5 QPSK 5 QPSK 5 QPSK 5 QPSK 5 16QAM 5 16QAM 5 16QAM 5 16QAM 5 16QAM 5 16QAM 5 16QAM RB Size 1 1 1 36 36 36 75 1 1 1 36 36 36 75 1 1 1 25 25 25 50 1 1 1 25 25 25 50 1 1 1 12 12 12 25 1 1 1 12 12 12 25 RB Offset 0 37 74 0 20 39 0 0 37 74 0 20 39 0 0 25 49 0 12 25 0 0 25 49 0 12 25 0 0 12 24 0 7 13 0 0 12 24 0 7 13 0 Conducted Power(dBm) 26865 831.5 23.24 23.13 23.11 22.38 22.17 22.19 22.24 22.39 22.19 22.21 21.39 21.33 21.32 21.26 26840 829 23.10 23.00 22.97 22.23 22.03 22.06 22.12 22.26 22.05 22.08 21.25 21.19 21.18 21.14 26815 826.5 23.12 22.99 22.98 22.24 22.04 22.05 22.10 22.25 22.04 22.09 21.25 21.20 21.19 21.12 26915 836.5 23.15 23.17 23.10 22.26 22.22 22.26 22.38 22.30 22.16 22.25 21.44 21.37 21.42 21.28 26915 836.5 23.03 23.02 23.02 22.22 22.06 22.08 22.23 22.19 22.00 22.07 21.37 21.17 21.30 21.11 26915 836.5 23.07 23.08 23.01 22.17 22.04 22.14 22.29 22.17 22.02 22.14 21.29 21.22 21.30 21.07 26965 841.5 23.18 23.16 23.13 22.29 22.17 22.21 22.38 22.29 22.17 22.23 21.47 21.33 21.46 21.24 26990 844 23.04 23.01 22.98 22.17 22.03 22.06 22.26 22.17 22.04 22.11 21.33 21.20 21.31 21.09 27015 846.5 23.06 23.01 23.00 22.16 22.04 22.08 22.24 22.16 22.03 22.11 21.32 21.20 21.33 21.10 ERP (dBm) 26865 831.5 20.69 20.58 20.56 19.83 19.62 19.64 19.69 19.84 19.64 19.66 18.84 18.78 18.77 18.71 26840 829 20.55 20.45 20.42 19.68 19.48 19.51 19.57 19.71 19.5 19.53 18.7 18.64 18.63 18.59 26815 826.5 20.57 20.44 20.43 19.69 19.49 19.5 19.55 19.7 19.49 19.54 18.7 18.65 18.64 18.57 26915 836.5 20.6 20.62 20.55 19.71 19.67 19.71 19.83 19.75 19.61 19.7 18.89 18.82 18.87 18.73 26915 836.5 20.48 20.47 20.47 19.67 19.51 19.53 19.68 19.64 19.45 19.52 18.82 18.62 18.75 18.56 26915 836.5 20.52 20.53 20.46 19.62 19.49 19.59 19.74 19.62 19.47 19.59 18.74 18.67 18.75 18.52 26965 841.5 20.63 20.61 20.58 19.74 19.62 19.66 19.83 19.74 19.62 19.68 18.92 18.78 18.91 18.69 26990 844 20.49 20.46 20.43 19.62 19.48 19.51 19.71 19.62 19.49 19.56 18.78 18.65 18.76 18.54 27015 846.5 20.51 20.46 20.45 19.61 19.49 19.53 19.69 19.61 19.48 19.56 18.77 18.65 18.78 18.55 Verdict Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Verdict Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Verdict Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Report no.: 2390387R-RF-US-P07V01 Page 39 / 95 DEKRA Testing and Certification (Suzhou) Co., Ltd. No.99 Hongye Rd., Suzhou Industrial Park, Suzhou, 215006, Jiangsu, China TEL: +86-512-6251-5088 / FAX: +86-512-6251-5098 Channel 26805 26915 27025 26805 26915 27025 Verdict Frequency (MHz) 825.5 836.5 847.5 825.5 836.5 847.5 3 QPSK 1 0 23.09 23.11 23.05 20.54 20.56 20.5 Pass 3 QPSK 1 8 23.00 23.02 23.03 20.45 20.47 20.48 Pass 3 QPSK 1 14 22.96 23.00 22.99 20.41 20.45 20.44 Pass 3 QPSK 8 0 22.24 22.20 22.17 19.69 19.65 19.62 Pass 3 QPSK 8 4 22.03 22.04 22.03 19.48 19.49 19.48 Pass 3 QPSK 8 7 22.05 22.12 22.09 19.5 19.57 19.54 Pass 3 QPSK 15 0 22.11 22.26 22.23 19.56 19.71 19.68 Pass 3 16QAM 1 0 22.25 22.14 22.17 19.7 19.59 19.62 Pass 3 16QAM 1 8 22.06 22.02 22.05 19.51 19.47 19.5 Pass 3 16QAM 1 14 22.07 22.08 22.09 19.52 19.53 19.54 Pass 3 16QAM 8 0 21.26 21.29 21.34 18.71 18.74 18.79 Pass 3 16QAM 8 4 21.20 21.22 21.19 18.65 18.67 18.64 Pass 3 16QAM 8 7 21.19 21.38 21.32 18.64 18.83 18.77 Pass 3 16QAM 15 0 21.12 21.11 21.09 18.57 18.56 18.54 Pass Channel 26797 26915 27033 26797 26915 27033 Verdict Frequency (MHz) 824.7 836.5 848.3 824.7 836.5 848.3 1.4 QPSK 1 0 23.05 23.08 23.07 20.5 20.53 20.52 Pass 1.4 QPSK 1 3 23.00 23.03 22.98 20.45 20.48 20.43 Pass 1.4 QPSK 1 5 22.95 23.01 22.96 20.4 20.46 20.41 Pass 1.4 QPSK 3 0 23.17 23.12 23.06 20.62 20.57 20.51 Pass 1.4 QPSK 3 1 23.03 23.11 22.99 20.48 20.56 20.44 Pass 1.4 QPSK 3 3 23.12 23.01 22.98 20.57 20.46 20.43 Pass 1.4 QPSK 6 0 22.08 22.30 22.08 19.53 19.75 19.53 Pass 1.4 16QAM 1 0 22.51 22.34 22.61 19.96 19.79 20.06 Pass 1.4 16QAM 1 3 22.59 22.54 22.74 20.04 19.99 20.19 Pass 1.4 16QAM 1 5 22.52 22.44 22.61 19.97 19.89 20.06 Pass 1.4 16QAM 3 0 22.17 22.01 22.07 19.62 19.46 19.52 Pass 1.4 16QAM 3 1 22.00 22.03 22.01 19.45 19.48 19.46 Pass 1.4 16QAM 3 3 21.98 22.09 21.89 19.43 19.54 19.34 Pass 1.4 16QAM 6 0 21.05 21.16 20.92 18.5 18.61 18.37 Pass Report no.: 2390387R-RF-US-P07V01 Page 40 / 95 DEKRA Testing and Certification (Suzhou) Co., Ltd. No.99 Hongye Rd., Suzhou Industrial Park, Suzhou, 215006, Jiangsu, China TEL: +86-512-6251-5088 / FAX: +86-512-6251-5098 4.2 Radiated Emissions VERDICT: PASS 4.2.1 Limit Band Standard FCC §22.917: The power of any emission outside of the authorized operating frequency ranges must be attenuated below the transmitting power (P) by a factor of at least 43 + 10 log(P) dB. FCC §90.691: For any frequency removed from the EA licensee's frequency block greater than 37.5 kHz, the power of any emission shall be attenuated below the transmitter power (P) in watts by at least 43 + 5/26 10Log10(P) decibels or 80 decibels, whichever is the lesser attenuation, where f is the frequency removed from the center of the outer channel in the block in kilohertz and where f is greater than 37.5 kHz. RSS-132: Section 5.5: The power of emissions in any 100 kHz bandwidth shall be attenuated (in dB) below the transmitter output power P (dBW) by at least 43 + 10 log10 p (watts). FCC §24.238: The power of any emission outside of the authorized operating frequency ranges must be attenuated below the transmitting power (P) by a factor of at least 43 + 10 log(P) dB. 2/25 RSS-133 Section 6.5: The emission power in any 1 MHz bandwidth shall be attenuated (in dB) below the transmitter output power P (dBW) by at least 43 + 10 log10 p(watts). FCC §27.53(g): For operations in the 600 MHz band and the 698-746 MHz band, the power of any emission outside a licensee's frequency band(s) of operation shall be attenuated below the transmitter power (P) within the licensed band(s) of operation, measured in watts, by at least 43 + 10 log (P) dB. Compliance with this provision is based on the use of measurement instrumentation employing a resolution bandwidth of 100 kilohertz or greater. However, in the 100 kilohertz bands immediately outside and adjacent to a licensee's frequency block, a resolution bandwidth of at least 30 kHz may be employed. FCC §27.53(c): On any frequency outside the 776-788 MHz band, the power of any emission shall be attenuated outside the band below the transmitter power (P) by at least 43 + 10 log (P) dB. 12/13/17 On all frequencies between 763-775 MHz and 793-805 MHz, by a factor not less than 65 + 10 log (P) dB in a 6.25 kHz band segment, for mobile and portable stations. RSS-130 Section 4.7: The unwanted emissions in any 100 kHz bandwidth on any frequency outside the low frequency edge and the high frequency edge of each frequency block range(s), shall be attenuated below the transmitter power, P (dBW), by at least 43 + 10 log10 p (watts), dB. Equipment operating in the frequency bands 746- 756 MHz and 777-787 MHz shall also comply with the following restrictions: The power of any unwanted emissions in any 6.25 kHz bandwidth for all frequencies between 763-775 MHz and 793-806 MHz shall be attenuated below the transmitter power, P (dBW), by at least: 65 + 10 log10 p (watts), dB, for mobile and portable equipment. The e.i.r.p. in the band 1559-1610 MHz shall not exceed -70 dBW/MHz for wideband signal and -80 dBW for discrete emission with bandwidth less than 700 Hz. FCC §27.53(h): The power of any emission outside a licensee's frequency block shall be attenuated below the transmitter power (P) in watts by at least 43 + 10 log10 (P) dB. 4/41 RSS-139 Section 6.6: The emission power in any 1 MHz bandwidth shall be attenuated below the transmitter output power P (in dBW) by at least 43 + 10 log10 p (watts) dB. Report no.: 2390387R-RF-US-P07V01 Page 41 / 95
Related FCC IDs:
- RBWEMCM100C - Elo Touch Solutions, Inc. POS [EMCM100C] 福昕PDF生成器版本8.0.2.0718