HTT202504129F02 RF Exposure-info

Wuchao (Shenzhen) Technology Development Co., Ltd. CLIPBUDS7 True Wireless Earphones 2BMKL-CLIPBUDS7 2BMKLCLIPBUDS7 clipbuds7

PDF Viewing Options

Not Your Device? Search For Manuals or Datasheets below:


File Info : application/pdf, 8 Pages, 354.00KB

Document DEVICE REPORTGetApplicationAttachment.html?id=8198869
Shenzhen HTT Technology Co., Ltd.

RF Exposure evaluation
Report Reference No...................... : HTT202504129F02 FCC ID............................................. : 2BMKL-CLIPBUDS7 Compiled by ( position+printed name+signature) . : File administrators
Supervised by ( position+printed name+signature) . : Project Engineer
Approved by ( position+printed name+signature) . : RF Manager

Date of issue .................................... : Apr. 08, 2025 Testing Laboratory Name ..............: Shenzhen HTT Technology Co.,Ltd.

Address............................................ : Applicant's name............................:

1F, Building B, Huafeng International Robotics Industrial Park, Hangcheng Road,Nanchang Community, Xixiang Street, Bao'an District, Shenzhen, Guangdong, China
Wuchao (Shenzhen) Technology Development Co., Ltd.

Address............................................ :

Room 1916, Tower A, Rongchuang Zhihui Building, Minzhi Street, Longhua District, Shenzhen City, Guangdong, China

Standard ........................................... :

47CFR §1.1310 47CFR §2.1093 KDB447498 D01 General RF Exposure Guidance v06

Shenzhen HTT Technology Co.,Ltd. All rights reserved.
This publication may be reproduced in whole or in part for non-commercial purposes as long as the Shenzhen HTT Technology Co.,Ltd. is acknowledged as copyright owner and source of the material. Shenzhen HTT Technology Co.,Ltd. takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context.

Test item description .....................: True Wireless Earphones

Manufacturer .................................... : Wuchao (Shenzhen) Technology Development Co., Ltd.

Trade Mark ........................................ HYUNDAI

Model/Type reference ...................... : Clipbuds 7 Modulation Type ............................... : GFSK, /4-DQPSK

Operation Frequency........................ : 2402MHz~2480MHz

Rating ............................................... : DC 3.7V From Battery and DC 5V From External Circuit

Result ............................................... : PASS

Shenzhen HTT Technology Co.,Ltd.

Tel: 0755-23595200 Fax: 0755-23595201

1F, Building B, Huafeng International Robotics Industrial Park, Hangcheng Road,Nanchang Community, Xixiang Street,

Bao'an District, Shenzhen, Guangdong, China

Page 1 of 8

Report No.: HTT202504129F02
TEST REPORT

Page 2 of 8

Equipment under Test : True Wireless Earphones

Model /Type

: Clipbuds 7

Applicant

: Wuchao (Shenzhen) Technology Development Co., Ltd.

Address

: Room 1916, Tower A, Rongchuang Zhihui Building, Minzhi Street, Longhua District, Shenzhen City, Guangdong, China

Manufacturer

: Wuchao (Shenzhen) Technology Development Co., Ltd.

Address

: Room 1916, Tower A, Rongchuang Zhihui Building, Minzhi Street, Longhua District, Shenzhen City, Guangdong, China

Test Result:

PASS

The test report merely corresponds to the test sample. It is not permitted to copy extracts of these test result without the written permission of the test laboratory.

Shenzhen HTT Technology Co.,Ltd.

Tel: 0755-23595200 Fax: 0755-23595201

1F, Building B, Huafeng International Robotics Industrial Park, Hangcheng Road,Nanchang Community, Xixiang Street,

Bao'an District, Shenzhen, Guangdong, China

Page 2 of 8

Report No.: HTT202504129F02

Page 3 of 8

Contents

1

TEST STANDARDS ................................................... 4

2

SUMMARY .............................................................. 5

2.1

General Remarks

5

2.2

Product Description

5

2.3

Special Accessories

5

2.4

Modifications

5

3

TEST ENVIRONMENT

6

3.1

Address of the test laboratory

6

3.2

Test Facility

6

3.3

Statement of the measurement uncertainty

6

4

TEST LIMIT

7

4.1

Requirement

7

4.2

Conducted Power Results

7

4.3

Manufacturing tolerance

8

4.4

Evaluation Result

8

4.5

Simultaneous Transmission for SAR Exclusion

8

5

CONCLUSION

8

Shenzhen HTT Technology Co.,Ltd.

Tel: 0755-23595200 Fax: 0755-23595201

1F, Building B, Huafeng International Robotics Industrial Park, Hangcheng Road,Nanchang Community, Xixiang Street,

Bao'an District, Shenzhen, Guangdong, China

Page 3 of 8

Report No.: HTT202504129F02

Page 4 of 8

1 TEST STANDARDS
The tests were performed according to following standards:
ANSI C95.1­1999: IEEE Standard for Safety Levels with Respect to Human Exposure to Radio Frequency Electromagnetic Fields, 3 kHz to 300 GHz. FCC KDB 447498 D01 General RF Exposure Guidance v06: Mobile and Portable Device, RF Exposure, Equipment Authorization Procedures. FCC CFR 47 part1 1.1310: Radiofrequency radiation exposure limits. FCC CFR 47 part2 2.1093: Radiofrequency radiation exposure evaluation: portable devices

Shenzhen HTT Technology Co.,Ltd.

Tel: 0755-23595200 Fax: 0755-23595201

1F, Building B, Huafeng International Robotics Industrial Park, Hangcheng Road,Nanchang Community, Xixiang Street,

Bao'an District, Shenzhen, Guangdong, China

Page 4 of 8

Report No.: HTT202504129F02

Page 5 of 8

2 SUMMARY

2.1 General Remarks
Date of receipt of test sample :

Apr. 01, 2025

Testing commenced on

: Apr. 01, 2025

Testing concluded on

:

2.2 Product Description

Apr. 08, 2025

Product Name:

True Wireless Earphones

Model/Type reference: Hardware version:

Clipbuds 7 /

Software version: Test samples ID: Power supply: Operation frequency: Modulation type: Antenna type: ANT Gain

/ HTT202504129-1# (Engineer sample) HTT202504129-2# (Normal sample) DC 3.7V From Battery and DC 5V From External Circuit
2402MHz~2480MHz GFSK, /4-DQPSK Chip Antenna
1.70 dBi

2.3 Special Accessories

The following is the EUT test of the auxiliary equipment provided by the laboratory:

Description Manufacturer

Model

Technical Parameters

Certificate

Provided by

/

/

/

/

/

/

2.4 Modifications
No modifications were implemented to meet testing criteria.

Shenzhen HTT Technology Co.,Ltd.

Tel: 0755-23595200 Fax: 0755-23595201

1F, Building B, Huafeng International Robotics Industrial Park, Hangcheng Road,Nanchang Community, Xixiang Street,

Bao'an District, Shenzhen, Guangdong, China

Page 5 of 8

Report No.: HTT202504129F02

Page 6 of 8

3 TEST ENVIRONMENT

3.1 Address of the test laboratory
Shenzhen HTT Technology Co.,Ltd. 1F, Building B, Huafeng International Robotics Industrial Park, Hangcheng Road,Nanchang Community, Xixiang Street, Bao'an District, Shenzhen, Guangdong, China

3.2 Test Facility
The test facility is recognized, certified, or accredited by the following organizations:
FCC-Registration No.: 779513 Designation Number: CN1319 Shenzhen HTT Technology Co.,Ltd. has been listed on the US Federal Communications Commission list of test facilities recognized to perform electromagnetic emissions measurements.
A2LA-Lab Cert. No.: 6435.01 Shenzhen HTT Technology Co.,Ltd. has been listed by American Association for Laboratory Accreditation to perform electromagnetic emission measurement.
The 3m-Semi anechoic test site fulfils CISPR 16-1-4 according to ANSI C63.10 and CISPR 16-1-4:2010.

3.3 Statement of the measurement uncertainty

The data and results referenced in this document are true and accurate. The reader is

cautioned that there may be errors within the calibration limits of the equipment and facilities.

The measurement uncertainty was calculated for all measurements listed in this test report

acc. to TR-100028-01" Electromagnetic compatibility and Radio spectrum Matters

(ERM);Uncertainties in the measurement of mobile radio equipment characteristics; Part 1"

and TR-100028-02 "Electromagnetic compatibility and Radio spectrum Matters

(ERM);Uncertainties in the measurement of mobile radio equipment characteristics; Part 2

" and is documented in the Shenzhen HTT Technology Co.,Ltd. quality system acc. to DIN

EN ISO/IEC 17025. Furthermore, component and process variability of devices similar to

that tested may result in additional deviation. The manufacturer has the sole responsibility of

continued compliance of the device.

Hereafter the best measurement capability for Shenzhen HTT Technology Co.,Ltd. :

Test

Range

Measurement Uncertainty

Notes

Radiated Emission

9KHz~30MHz

3.12 dB

(1)

Radiated Emission

30~1000MHz

4.37 dB

(1)

Radiated Emission

1~18GHz

5.40 dB

(1)

Radiated Emission

18-40GHz

5.45 dB

(1)

Conducted Disturbance

0.15~30MHz

2.68 dB

(1)

Shenzhen HTT Technology Co.,Ltd.

Tel: 0755-23595200 Fax: 0755-23595201

1F, Building B, Huafeng International Robotics Industrial Park, Hangcheng Road,Nanchang Community, Xixiang Street,

Bao'an District, Shenzhen, Guangdong, China

Page 6 of 8

Report No.: HTT202504129F02

Page 7 of 8

4 Test limit

4.1 Requirement
According to KDB447498 D01 General RF Exposure Guidance v06 Section 4.3.1 Standalone SAR test exclusion considerations: "Unless specifically required by the published RF exposure KDB procedures, standalone 1-g head or body and 10-g extremity SAR evaluation for general population exposure conditions, by measurement or numerical simulation, is not required when the corresponding SAR Test Exclusion Threshold condition, listed below, is satisfied. These test exclusion conditions are based on source-based time-averaged maximum conducted output power of the RF channel requiring evaluation, adjusted for tune-up tolerance, and the minimum test separation distance required for the exposure conditions.22 The minimum test separation distance is determined by the smallest distance from the antenna and radiating structures or outer surface of the device, according to the host form factor, exposure conditions and platform requirements, to any part of the body or extremity of a user or bystander (see 5) of section 4.1). To qualify for SAR test exclusion, the test separation distances applied must be fully explained and justified by the operating configurations and exposure conditions of the transmitter and applicable host platform requirements, typically in the SAR measurement or SAR analysis report, according to the required published RF exposure KDB procedures. When no other RF exposure testing or reporting is required, a statement of justification and compliance must be included in the equipment approval, in lieu of the SAR report, to qualify for the SAR test exclusion. When required, the device specific conditions described in the other published RF exposure KDB procedures must be satisfied before applying these SAR test exclusion provisions; for example, handheld PTT two-way radios, handsets, laptops & tablets etc.23 " [(max. power of channel, including tune-up tolerance, mW)/ (min. test separation distance, mm)] ·[f (GHz)]  3.0 for 1-g SAR and  7.5 for 10-g extremity SAR, where: · f (GHz) is the RF channel transmit frequency in GHz · Power and distance are rounded to the nearest mW and mm before calculation · The result is rounded to one decimal place for comparison · 3.0 and 7.5 are referred to as the numeric thresholds in the step 2 below
The test exclusions are applicable only when the minimum test separation distance is  50 mm and for transmission frequencies between 100 MHz and 6 GHz. When the minimum test separation distance is < 5 mm, a distance of 5 mm according to 5) in section 4.1 is applied to determine SAR test exclusion.

4.2 Conducted Power Results

Mode GFSK Pi/4DQPSK

TX Type SISO
SISO

Frequency Packet

(MHz) 2402 2441 2480 2402 2441 2480

Type DH5 DH5 DH5 2DH5 2DH5 2DH5

Maximum Peak Conducted Output
Power (dBm)

ANT1

Limit

-2.8

<=20.97

-3.67

<=20.97

-4.3

<=20.97

-1.74

<=20.97

-2.72

<=20.97

-3.33

<=20.97

Shenzhen HTT Technology Co.,Ltd.

Tel: 0755-23595200 Fax: 0755-23595201

1F, Building B, Huafeng International Robotics Industrial Park, Hangcheng Road,Nanchang Community, Xixiang Street,

Bao'an District, Shenzhen, Guangdong, China

Page 7 of 8

Report No.: HTT202504129F02
4.3 Manufacturing tolerance

Page 8 of 8

Channel Target (dBm) Tolerance ±(dB)
Channel Target (dBm) Tolerance ±(dB)

GFSK (Peak)

Channel 0

Channel 39

-2.0

-3.0

1.0

1.0

/4DQPSK (Peak)

Channel 0

Channel 39

-1.0

-2.0

1.0

1.0

Channel 78 -4.0 1.0
Channel 78 -3.0 1.0

4.4 Evaluation Result

Evaluation Results

Band/Mode f (GHz)

BT

2.480

Antenna Distance
(mm)
5

RF output power

(including tune-up

tolerance)

dBm

mW

0.0

1.0000

SAR Test Exclusion Threshold

SAR Test Exclusion

0.3150<3.0

Yes

4.5 Simultaneous Transmission for SAR Exclusion

N/A
5 Conclusion
The measurement results comply with the FCC Limit per 47 CFR 2.1093 for the uncontrolled RF Exposure and SAR Exclusion Threshold per KDB 447498 D01v06