Kit inclusions3 Installation configuration and placement4 Kit wiring connection5 Datasheets 6 User Guide118 Warranty 19
The MyHOME Lighting Control and Energy Monitoring Kit provides a solution to control lighting circuits, switching and dimming, and the ability to monitor energy consumption. It includes a 3.5" colour touchscreen for centralised management of all functions and easy monitoring of energy consumption. This kit comes factory pre-programmed.

Kit inclusions

23

Kit Catalogue Number: MHKIT4
MHKIT4 Contents:
 1 x power supply, 600mA output (Cat. No. E49)  3 x trailing Edge single channel 400VA dimmer(Cat. No. F418). To drive 3 separate
dimmer circuits (Zone 1-2-3). Suitable for incandescent, CFL and LED fixtures  1 x double channel 6A relay per channel (Cat. No. F411/2). To drive 2 separate lights in
the ON/OFF function (Zone 4-5)  1 x 2 gang switches (Cat. No. 67552). Controls 2 on/off lighting channels  1 x 3 gang switches (Cat. No. 67554). Controls 3 dimmer lighting channels  3 x current meter (Cat. No. F520). To monitor 3 phase power consumption of the house  1 x scenario unit (Cat. No. F420) controls 16 different scenarios from the 3.5"touchscreen  1 x 3.5" touchscreen (Cat. No. 573958). Controls and monitors every single load of
automation system, plus the scenario and energy consumption  1 x 24 din module enclosure box (Cat. No. HL24S). Allows installation of all DIN devices
in a single point for easy access
Functionality of the KIT:
 Control the dimming of your lights with a dedicated dimmer switch or the 3.5" touchscreen
 Switch your lights on/off using a dedicated switch or the 3.5" touchscreen  U se the 3.5" touchscreen as a central controller to drive the Automation system
(light-dimmer ­ 3 phase-energy monitoring)  Use a mobile device, such as a smart phone or tablet, to remotely monitor and control
the lighting, automation scenarios and your energy consumption*
*Mobile device, App and WiFi access point not included in this kit. Recommend using HPM or Legrand dimmable LED fixtures.
Mobile device activation
For further details on mobile setup please contact the Legrand Customer Service team on 1300 369 777.
Warranty
Legrand 4 year extended warranty. See page 15 for details.

Installation configuration and placement plan

Example

Zone 4 relay

Zone 1 dimmer

Zone 2 dimmer

Zone 3 - dimmer

Zone 5 - relay

0

1

3

6m

Kit wiring connection

45

L1 L2 L3

N

L

L

N

Zone 4 & 5 Zone 1
T 1,6H 250 V

12W19 ID

220-240V ~ 50 - 60 Hz 110-127V ~ 50 - 60 Hz

200W 100W

F411/2

F418

Panel Board

L

L

N

N

Zone 2 T 1,6H 250 V Zone 3 T 1,6H 250 V

12W19 ID

220-240V ~ 50 - 60 Hz 110-127V ~ 50 - 60 Hz

200W 100W

F418

12W19 ID

220-240V ~ 50 - 60 Hz 110-127V ~ 50 - 60 Hz

200W 100W

F418

NL

NL

NL

230 Vac C16

230 Vac C16

230 Vac C16

F520

F520

PRI SCS

DEL

F520 E49

F420

SCS Cable Cat. No. 336 904

Dimmer

Switch

Touchscreen

Zone 1-2-3 Zone 4-5

Command Switch

The dimension of the enclosure box (CAT No. HL24S) are:

330 (1)

LAN
Connect CAT5/CAT6 to your home network for
smart phone app.

72 47.5

A (1) 125
B (2)

86.5

350 (2)

Datasheets
2 relay actuator in DIN module

Description
Actuator for installation in DIN rail distribution boards or switchboards. This device incorporates two independent relays for the activation of 2 loads, and includes local control pushbuttons for each individual load, which are only active if the actuator has been configured. The device can be installed in a MyHOME system and configured physically or virtually. In this case when the PL1 and PL2 positions are configured using the same configurator the device interlocks the relays, to which it is possible to connect motors of rolling shutters, curtains, etc. When installed as a component of the Lighting Management system, specific configuration procedures are used (Plug&go, Project&Download).

Technical features
Power supply from BUS: Operating power supply with SCS BUS: Absorption: Number of outputs: Power/Absorption of driven loads:

27 Vdc 18 - 27 Vdc 28 mA 2 x 6 A

Incandescent lamps Halogen lamp

LED lamp Compact fluorescent lamp

F411/2

1 23 4 ART. F411/2

C1 C2
4

3

2

1

230 Vac

1380 W

6 A

250 W

Max. 4 lamps

Linear fluorescent lamp Electronic transformer

Ferromagnetic transformers

Motor reducers for rolling shutters

Legend
1. Configurator socket (attention, it must only be used in MyHOME systems with physical configuration) 2. BUS 3. LED 4. Push-button

230 W

1 A 2 A cos 0.5 460 VA 460 W

2 A

Dissipated power with max load: Operating temperature: Number of outputs:

1.7 W(1) (-5) ­ (+45) ºC 2 x 6 A

NOTE: (1) The dissipated power indicated is that corresponding to the device with all the relays loaded at the maximum load. With lower loads also the dissipated power is lower and may be calculated by means of the following formula: P(mW)=140+400*N+10*(Ic1+Ic2) P: dissipated power in mW, N: no. of loaded relays, IN: load current corresponding to the N relay.

Dimensional data
Size: 2 DIN modules
MyHOME Configuration
When installed in a MyHOME system, the device may be configured in two ways:  PHYSICAL CONFIGURATION, by connecting the physical
configurators to their sockets.  VIRTUAL CONFIGURATION, by connecting the system to the
PC using the Kit or the Web server. The Virtual configurator software must be installed on the PC.

F411/2

67

Physical configuration
The actuator performs all the basic operating modes that can be configured directly on the control. Moreover further operating modes with the configurator in position M of the same actuator are listed in the table below.

Possible function
Timed stop for motors. The device deactivates after the time set has elapsed(1). This mode is only operative if LP1=LP2 (same configurators), i.e. with the two relays interlocked
Master actuator with OFF control delayed on the corresponding Slave actuator. With the OFF control the Master actuator deactivates; the Slave actuator deactivates after the time set with the configurators has elapsed(2). This model is only operative if PL1PL2.
Actuator as Slave. Receives a control sent by a Master actuator with the same address.
Push-button (ON monostable) ignores Room and General controls.

Configurator in M none - 9(1)
none - 4(2)
SLA PUL

Configurator No configurator 1 2 3 4
5 6 7 8 9

Time (minutes) 1 2 5 10 infinite or until the next control 20 sec 10 sec 5 sec 15 sec 30 sec

2) The value of the configurator listed in the table defines the final time, after which the actuator disables its own slave.

Configurator No configurator 1 2 3 4

Time (minutes) 0 1 2 3 4

Virtual configuration
Using the Virtual configurator software it is possible to perform all the functions listed below:  light actuator  rolling shutter actuator
Lighting Management configuration
When installed in a Lighting Management system, the device can be configured in the following ways:  Plug&Go (see the dedicated technical guide)  Project&Download,
Using the Virtual configurator software it is possible to perform all the functions listed below:  Light actuator
Wiring diagrams

Diagram for the connection of lighting devices

N

A PL M

L

G1 G2

PL

1 23 4 ART. F411/2
C1 C2

1 2 3 4 MIN 3m L N

LN

N

L

PL

Diagram for the control of a 230 Vac motor with 2 windings

N L
M
L1 L2

F411/2 actuator

M = motor in AC with 2 windings

L1-N = clockwise rotation L2-N = anticlockwise rotation

Datasheets
Bus meter with 3 inputs for toroids

Description
The SCS device measures currents and voltages of separate lines (up to 3), connecting maximum three toroids to the appropriate inputs (one toroid, item 3523 supplied as standard).
The meter processes and saves the following variables:  instantaneous power in W;  total energy accumulated in Wh.
The device has an internal memory that allows saving the following information:  cumulative energy on an hourly basis for the last 12 months;  cumulative energy on a daily basis for the last 2 years;  cumulative energy on a monthly basis for the last 12 years.
In order to allow the device to archive consumption information,
the system must be fitted with a device capable of supplying current date and time information (e.g. Touchscreen). If this information is not available, the meter will be unable to archive the data, and will continue calculating the values of the instantaneous variables (power). The space requirement for the device is equal to 1 DIN module. The device is provided with socket for 5 configurators: A1, A2, A3-Ta, A3-Tb, A3-Tc.

Technical features
Operating power supply with SCS BUS: Absorption: Rated current: Maximum current: Operating temperature:

18 - 27 Vdc 35 mA max 16 A 90 A 5 ­ 40 ºC

Dimensional data Size: 1 DIN module

Front view 5
4 Top view

F520 1 2
3
6 1

Legend
1. 230 Vac connection 2. Push-button for the deletion of cumulative energy data 3. Configurator sockets closing door 4. SCS/BUS connection 5. User interface LED, SEE TABLE 6. Ta, Tb, Tc connectors for toroids, item 3523

F520

89

Configuration
The device can be configured by connecting the physical configurators to the correct sockets (Physical configuration).
The device is provided with socket for five configurators:  A1 for the hundreds  A2 for the tens  A3 Ta for the units  A3 Tb for the units  A3 Tc for the units
The combination of the configurators defines:  A1/A2/A3-Ta address of meter A  A1/A2/A3-Tb address of meter B  A1/A2/A3-Tc address of meter C The maximum number of addresses is 255.
WARNING: The A3-Ta configurator cannot be zero, differently
from configurators A3-Tb and A3-Tc, which can have a zero value (if the corresponding input is not managed). The meter must be installed as close as possible to the power supply, to ensure a high BUS voltage, and enable correct management of memory savings in case of voltage cut. If the supply voltage is insufficient (below 21 Vdc), the meter will cause the green LED to flash to signal the installation error. The device will work regularly, but will not guarantee correct saving and recovery of data in case of BUS failure.

Procedure for the deletion of the cumulative energy data: 1 Press the key; after 20 seconds the orange LED flashes quickly;
release the key. 2 All the cumulative energy data are reset.
LED notifications based on the status of the power meter

Device status Normal operation BUS problems (BUS voltage insufficient, or voltage drop detected) Installation error (230 Vac not detected)
Configuration error
No configuration

LED
GREEN
GREEN flashing 500 ms/500 ms
RED flashing 100 ms/900 ms
ORANGE flashing irregularly on GREEN
ORANGE flashing 128 ms/128 ms on GREEN

Wiring diagrams
Connection of the meter to the bus, the line, and the toroid 230 Vac C16
NL
BUS

Datasheets
Scenario module

Description
This device allows you to manage scenarios for Automation, Sound system and Temperature Control systems which have been created, modified and activated using different devices of the Automation system. Up to 16 scenarios may be saved in the scenario module, with up to 100 controls each. The scenarios can also give door entry and Video door entry controls for onefamily systems to switch on the staircase lights and open the door lock. If installed in large systems with interface item F422 in logical expansion, the module can save automation controls for the system where it is installed. On the front cover of the item there are two keys and two LED. The first push-button (padlock) locks or unlocks the programming procedure avoiding involuntary operations such as cancelling the scenarios and the corresponding LED indicates the status: green programming possible, red programming blocked, orange temporary block. The second push-button (DEL) cancels all the scenarios, the LED underneath indicates that the cancellation has taken place or that the device is performing the learning procedure.

Technical features
Power supply from SCS BUS: Operating power supply with SCS BUS: Absorption: Operating temperature: Size:

27 Vdc 18 - 27 Vdc 20 mA 0 ­ 40 ºC 2 DIN modules

F420

DEL

6

1

5

2

4

3

Front view

Legend
1. Scenario cancellation push-button 2. Scenarios/learning reset LED 3. Configurator socket 4. BUS 5. Programming status LED 6. Lock/unlock programming push-button

F420

10 11

Configuration
The combination of the scenario module with a control device is ensured by assigning to both items the same address. This is identified by the configurators with a numeric value for position A = 0-9 and position PL = 1-9. When using a Touchscreen, the address of the scenario module must be specified during programming, using the Tidisplay software. Several scenario modules may be installed in one system, allocating a different address to each module.
Scenario programmer In order to program, change or cancel a scenario, it is necessary to enable the programming mode of the Module item F420 so that the status LED is green (press the lock/unlock key on the Scenario Module for at least 0.5 seconds); continue with the following operations:
1) press one of the four control keys the scenario should be
associated to for 3 seconds. The corresponding LED starts flashing; 2) set the scenario using the corresponding controls for the various Automation, Temperature control, Sound system, etc. functions; 3) Confirm the scenario by quickly pressing the corresponding key on the control to exit programming mode; 4) to change or create new scenarios to be linked to the other keys, repeat the procedures starting from point 1.
To call a set scenario just press its push-button on the control quickly. If the module does not receive any input for 30 minutes from the start of the learning procedure, programming will automatically be interrupted. To cancel a scenario completely, keep the corresponding push-button pressed for about ten seconds. To erase the entire memory keep the DEL push-button on the Scenario module pressed for 10 seconds, the yellow "reset scenarios" LED flashes quickly. Once the operations have been performed lock the programming by pressing the lock/unlock push-button for at least 0.5 seconds, so that the corresponding LED becomes red.

key 1
LED key 1-3 key 3

key 2
LED key 2-4 key 4

NOTES: Inside the system itself one Scenario module can be programmed at a time as the other devices are temporarily locked; during this phase the "programming status" LED becomes orange signalling the temporary Lock. During the learning procedure and when there are timed controls or group controls, the Scenario module does not save events for 20 seconds. You must thus wait before continuing with creating the scenario. During the scenario learning procedure only the changes of status are saved. The scenario module should be configured with a different A and PL address from that of an actuator. Use A=0 and PL=1 to 9, which cannot be used by actuators. If the configuration is wrong the Programming status LED flashes ORANGE. In case of "virtual" configuration the LED flashes RED.

Datasheets

67552

Basic control for 2 independent loads

Description
Two-module, push mounted and lowered special control with 4 push-buttons and 4 LEDs. The device can control one single actuator for single or double loads, or two actuators for single or double loads, independent from each other. The device may be installed in a MY HOME system and can be configured both physically and virtually, or as a component of the Lighting Management system, using specific configuration procedures (Plug&go, Push&Learn, Project&Download).

Technical features

Power supply from SCS BUS:

27 Vdc

Operating power supply with SCS BUS: 18 ­ 27 Vdc

Absorption with maximum LED intensity: 6 mA for H4652/2

and 067552

8.5 mA for L4652/2

and AM5832/2

Dimensional data Size: 2 push mounted modules

Dimensional data
When installed in a MY HOME system, the device may be configured in two ways: - PHYSICAL CONFIGURATION, by connecting the physical
configurators to their sockets. - VIRTUAL CONFIGURATION, by connecting the system to the PC
using the 3503N Kit or the web server. The Virtual configurator software must be installed on the PC

Lighting Management configuration
When installed in a Lighting Management system, the device can be configured in the following ways: - Plug&Go (see the dedicated technical guide) - Push&Learn - Project&Download, Using the Virtual Configurator software it is possible to perform all the functions listed below: - double light control - double CEN control - double CEN PLUS control - double AUX control For more information on the functions see the glossary before the Technical sheets chapter.

1 1
2 2

3

5

3

5

4 4

6
6
A PL/PF
M LIV1A/AUX
PLLIV/P2F SMPE LIV1/IAUX LIV2 SPE
I
7
7
Legend
1. LED 2. Upper push-button 3. Lower push-button 4. LED 5. Push-button for LED adjustment/exclusion 6. Configurator socket (attention, it must only be used
in MyHOME systems with physical configuration) 7. BUS
LED adjustment

PUSH t > 2 s

30%

DEFAULT 60%

0%

100%

67552
Configuration Possible function

Combination of key covers used/Configurator in M1 and M2

1 Function

2 Functions

12 13

ON control

ON

OFF control

OFF

Timed ON control2)

1 ­ 8

Dimmer - ON control (upper key)

OFF (lower key) + adjustment1)

­

Cyclical ON-OFF control + adjustment1)

no configurator

UP/DOWN rolling shutter to end of stroke

­

Monostable rolling shutter UP/DOWN

­

Bistable rolling shutter up-down movement. ­ Blades adjustment if the pressure time is less than 1.5 s. Up-down to the end of travel if the control is pressed for more than 1.5 s.

Push-button (ON monostable)

PUL

Activation of scenarios managed by the

­

programmer MH200N3)

Push-button (ON monostable)
Activation of scenarios managed by the programmer MH200N3)

Time (minutes) ­ PUL ­
Configurator

­ ­ ­
0/I ­
M 6
­ CEN
6 ­ CEN Time (minutes)

Virtual configuration
Using the Virtual Configurator software it is possible to perform all the functions listed below: - double scenario control - double CEN control - double scenario PLUS control - double CEN PLUS control.

Datasheets
Basic Control of TBA

Description
Three module flush-mounting control, with six pushbuttons and three status notification LEDs. This can be used to control 1-relay single load actuators, 2 interlocked relay actuators, and to send controls for the management of advanced devices, when configured with the CEN configurator.

Technical data
Power supply from SCS BUS: Consumption:

18 ­ 27 Vdc 9 mA

Dimensional data
Size: Depth:

3 flush-mounting modules 20.7 mm

LED adjustment

67554

PUSH t > 2 s

30%

DEFAULT 60%

0%

100%

Dimensional data
1. Upper pushbutton 2. Lower pushbutton 3. LED 4. LED adjustment/exclusion pushbutton 5. Control 1 6. Control 2 7. Control 3 8. BUS

67554

14 15

Configuration
Device with three independent controls. It can drive actuators for 1-relay single loads and actuators with 2 interlocked relays and can send controls for the management of advanced devices, if configured using the CEN configurators. On the back of the device there are three distinct A and PL positions, which refer to the same number of pushbuttons on the front. From left to right, the three front pushbuttons correspond to control 1 (A1, PL1), control 2 (A2, PL2) and control 3 (A3, PL3).

Configurator value in position M Key covers used/function

Configurator value in position M

Key covers used/function

no configuration

cyclic ON-OFF

Configurator value in position M Key covers used/function

1

cyclic ON-OFF UP-DOWN

4

cyclic ON-OFF monostable

UP-DOWN

7

cyclic ON-OFF ON (upper key)

OFF (lower key)

Configurator value in position M

Key covers used/function

3 6 9
CEN

UP-DOWN

1

monostable UP-DOWN

ON (upper key)

4

OFF (lower key) 7
enabling the T1-T2-T3 (upper) and T4-T5-T6 (lower) keys to manage scenarios of the programmer 0035 65.*

NOTE (*): Do not configure positions A2, PL2 and A3, PL3.

Virtual configuration
Using the Virtual Configurator software it is possible to perform all the functions listed below: - triple scenario control - triple CEN control - triple scenario PLUS control - triple CEN PLUS control.

cyclic UP-DOWN ON-OFF
cyclic monostable UP-DOWN ON-OFF
cyclic ON (upper key) ON-OFF OFF (lower key)

Datasheets
SCS Dimmer

Technical features
Halogen lamps

LED dimmer lamps

Compact CFL dimmer lamps

220 ­ 240 Vac 110 ­ 127 Vac

200 W 100 W

0,9 A 0,9 A

200 W 100 W

0,9 A 0,9 A

200 W 100 W

0,9 A 0,9 A

 Product tested using main brands of lamp  NO connection mixed loads  NO installation of several dimmers side by side  NO installation of a dimmer side by side with a power supply
Wiring diagrams

L N

T1,6H 250V

230V
C16

12W19 ID

F418

220-240V ~ 50 - 60 Hz 110-127V ~ 50 - 60 Hz

200W 100W

BUS SCS
 Green LED = load voltage OFF  Red LED = load ON  Flashing LED = load fault

T1,6H 250V

F2121400--12184207VV

~ ~

50 50

-

60 60

Hz Hz

12W19 ID
210000WW

ATTENTION: when replacing faulty fuses always disconnect the supply voltage (open the main switch).

F418

12W1ID9

T1,6H 250V

210000WW

F2121400--12184207VV

~ ~

50 50

-

60 60

Hz Hz

E49
Power supply

16 17

Warning
During the operation of electric devices powered by the electric power line, some parts may be subjected to dangerous voltage levels. The installation and assembly of the device must be performed in accordance with the following installation rules:  the power supply must only be installed and assembled by
qualified personnel;  the power supply must only be installed inside switchboards
suitable for DIN devices;  the device is only suitable for indoor installation;  the device must be kept away from water drips and sprays.  an omnipolar switch with minimum 3mm distance between
contacts must be installed near the power supply;  the above described switch is to be used as the device for
disconnecting the power supply from the power line;  ensure that during the assembly of the devices the power
supply is not connected to the power line;  before powering the system, check the cable connections,
and ensure that the line voltage is compatible with the power supply;  the installation must be completed in accordance with current installation rules. Improper use of any items may compromise their safety.

Technical features
PRI (AC power supply input)  Rated voltages:  Rated currents:  Nominal working voltages:  Nominal working frequencies:  Power consumption at full load:  Power consumption:  Performance at full load:  Stand-by consumption:  Operating temperature:  Integrated fuse (PRI side):

220 ­ 240 V 200 ­ 190 mA 187 ­ 265 V 50 ­ 60 Hz 21.5 W max 5.3 W max 80% typ. less than 1 W 5 ­ 40 ºC F1 T2A 250 V

SCS  Rated voltage:  Rated current:  Rated power:

27 V +/­100 mV 0 ­ 0,6 A 16,2 W

PRI: 220 ­ 240 V~ 200 ­ 190 mA 50/60 Hz
PRI
SCS
Legend Green LED - power supply on Red LED - output current overload

27 Vdc 600 mA

User Guide
Scenarios
Lets you activate scenarios that have been previously stored in one or more "scenario units" and "scenario modules" of your MyHOME system. Touch the scenario icon . The display will show the page where you can find the scenarios you can activate.
NIGHT
Scenario 1
Scenario 2
Touch the icon to activate the scenario.
Scenario 1 This command lets you activate a scenario of the Scenario Module. Furthermore, when you touch the icon , new icons will appear which will allow you to cancel or programme a new scenario according to the functioning mode of the Scenario Module.
If the icon is not displayed, the scenarios module is blocked.
Creating a new scenario

1

2

3

1. Touch the icon to start a new scenario programming procedure. 2. Prepare your scenario by adjusting the light level of the dimmer and the lights (on or off). 3. Return to the touch screen and touch the scenarios 4. Touch the icon to end programming. 5. Touch the icon to return to the menu of the scenarios programmed by you.

Removing a scenario

1
1. Touch the icon to remove a scenario programmed by you.

Warranty

18 19

4 year extended warranty

Legrand understands the importance of having dependable products that work efficiently and effectively thus they offer a 4 year extended warranty on the MyHOME Lighting Control and Energy Monitoring kit. When you buy this kit you can be certain that the product lives up to the high standards of Legrand and that if in the unlikely event there is a problem with your kit, it will be repaired by a fully qualified and experienced Legrand technician.
HPM Legrand will honour all statutory guarantees that you as a consumer are entitled to rely upon under the Australian Consumer Law against a manufacturer including a guarantee that any products HPM Legrand has manufactured or imported/ the products which are described in this Instruction Manual (Products) are of acceptable quality.
To make a claim under any statutory guarantee or other warranty you should first contact the supplier, contractor or retailer from whom you purchased the Products.
1. HPM Legrand ("we" or "us") has given each Purchaser who is a Consumer ("you") a warranty against defects in its Products.
2. As a Consumer you are entitled to the benefit of the Warranty and should read and understand its terms. In addition for the purposes of the Australian and New Zealand Consumer Laws, we note the following:

(a) Our contact details for the purpose of any claims made under the Warranty are below:

AUSTRALIA ONLY Legrand Australia Pty Ltd Nexus Industry Park Bldg 4, 43-47 Lyn Pde PRESTONS NSW 2170 1300 369 777 [email protected]

NEW ZEALAND ONLY HPM Legrand New Zealand Ltd 106-124 Target Rd GLENFIELD AUCKLAND 0627 0800 476 009 [email protected]

(b) Any claim under the Warranty must sent in writing to the following address:

AUSTRALIA ONLY Warranty Claims Officer ­ Consumer Products Legrand Australia Pty Ltd Nexus Industry Park Bldg 4, 43-47 Lyn Pde PRESTONS NSW 2170

NEW ZEALAND ONLY Warranty Claims Officer ­ Consumer Products HPM Legrand New Zealand Ltd 106-124 Target Rd GLENFIELD AUCKLAND 0627

(c) If we accept your claim under the Warranty we will reimburse all your reasonable expenses in making and pursuing the claim, including the cost of reimbursement of any defective Products returned in the ordinary course to us at the address above by post or other agreed means. Any such claim must be made within 14 days of your receiving notice of our acceptance of your claim and include any necessary supporting documentation or invoices.

3. A s a Consumer you have rights under the Australian and New Zealand Consumer Laws and may have rights under other applicable laws which cannot be excluded, restricted or modified. Those rights are in addition to any rights you have under the Warranty.

4. O ur goods (which we refer to in the Warranty as the Products) come with guarantees that cannot be excluded under the Australian and New Zealand Consumer Laws. You are entitled to a replacement or a refund for a major failure and for compensation for any other reasonably foreseeable loss or damage. You are also entitled to have the goods repaired if the goods fail to be acceptable quality and the failure does not amount to a major failure.

04_2014 LE07377AAA

HPM Legrand Australia Building 4, Nexus Industry Park Lyn Parade, Prestons NSW 2170 Tel: 1300 369 777 www.legrand.com.au
HPM Legrand New Zealand 106-124 Target Road, Glenfield Auckland 0627 New Zealand Tel: 0800 476 009 www.legrand.co.nz
4.5 Zimmerwohnung 116.5 m2


Adobe PDF Library 10.0.1 Adobe InDesign CS6 (Macintosh)

Search Any Device: