Test report

BCS Automotive Interface Solutions (Suzhou) Co., Ltd WPC003-5 Wireless Charger 2AXPS-WPC003-5 2AXPSWPC0035 wpc003 5

PDF Viewing Options

Not Your Device? Search For Manuals or Datasheets below:


File Info : application/pdf, 31 Pages, 739.78KB

Document DEVICE REPORTGetApplicationAttachment.html?id=5799213
DEKRA Testing and Certification (Suzhou) Co., Ltd. No.99 Hongye Rd., Suzhou Industrial Park, Suzhou, 215006, Jiangsu, China TEL: +86-512-6251-5088 / FAX: +86-512-6251-5098

Test report No: 2190851R-RF-US-P06V01

FCC TEST REPORT & ISED TEST REPORT

Product Name Trademark

Wireless Charger BCS

Model and /or type reference FCC ID Applicant´s name / address
Test method requested, standard Verdict Summary

WPC003-5
2AXPS-WPC003-5
BCS Automotive Interface Solutions(Suzhou)Co.,Ltd No.2052 Taidong Road Xiangcheng Economic Development District,215413 Suzhou China FCC CFR Title 47 Part 15 Subpart C ANSI C63.10: 2013 IN COMPLIANCE

Documented by (name / position & signature) Adma Lu/Project Engineer

Approved by (name / position & signature)

Jack Zhang/ Supervisor

Date of issue Report Version Report template No

2022-03-28 V1.1 Template_FCC Part 15C-RF-V1.0

DEKRA Testing and Certification (Suzhou) Co., Ltd. No.99 Hongye Rd., Suzhou Industrial Park, Suzhou, 215006, Jiangsu, China TEL: +86-512-6251-5088 / FAX: +86-512-6251-5098

INDEX

page General conditions ......................................................................................................................................................4 Environmental conditions ............................................................................................................................................4 Possible test case verdicts ..........................................................................................................................................5 Abbreviations ..............................................................................................................................................................5 Document History .......................................................................................................................................................6 Remarks and Comments.............................................................................................................................................6 Used Equipment .........................................................................................................................................................7 Uncertainty .................................................................................................................................................................8 1 General Information............................................................................................................................................9
1.1 General Description of the Item(s) ............................................................................................................9 1.2 Antenna Information ...............................................................................................................................10 1.3 Channel List ...........................................................................................................................................11 2 Description of Test Setup .................................................................................................................................12 2.1 Operating mode(s) used for tests............................................................................................................12 2.2 Auxiliary equipment / Test software for the EUT......................................................................................12 2.3 Test Configuration / Block diagram used for tests ...................................................................................13 2.4 Testing process......................................................................................................................................14 3 Verdict summary section ..................................................................................................................................15 3.1 Standards...............................................................................................................................................15 3.2 Deviation(s) from the Standard(s) / Test Specification(s).........................................................................15 3.3 Overview of results.................................................................................................................................16 3.4 Test Facility............................................................................................................................................17 4 Test Results.....................................................................................................................................................18 4.1 AC Power Line Conducted Emission ......................................................................................................18
4.1.1 Limit .............................................................................................................................................18 4.1.2 Test Setup....................................................................................................................................18 4.1.3 Test Procedure.............................................................................................................................18 4.1.4 Test Data .....................................................................................................................................19 4.2 Radiated emission..................................................................................................................................20 4.2.1 Limit .............................................................................................................................................20 4.2.2 Test Setup....................................................................................................................................21 4.2.3 Test Procedure.............................................................................................................................21 4.2.4 Test Data .....................................................................................................................................22 4.3 20dB Bandwidth .....................................................................................................................................28

Report no.: 2190851R-RF-US-P06V01

Page 2 / 31

DEKRA Testing and Certification (Suzhou) Co., Ltd. No.99 Hongye Rd., Suzhou Industrial Park, Suzhou, 215006, Jiangsu, China TEL: +86-512-6251-5088 / FAX: +86-512-6251-5098
4.3.1 Limit .............................................................................................................................................28 4.3.2 Test Setup....................................................................................................................................28 4.3.3 Test Procedure.............................................................................................................................28 4.3.4 Test Data .....................................................................................................................................29 4.4 Antenna Requirement.............................................................................................................................30 4.4.1 Limit: ............................................................................................................................................30 4.4.2 Antenna Connector Construction: .................................................................................................30 5 Test setup photo and EUT Photo......................................................................................................................31

Report no.: 2190851R-RF-US-P06V01

Page 3 / 31

DEKRA Testing and Certification (Suzhou) Co., Ltd. No.99 Hongye Rd., Suzhou Industrial Park, Suzhou, 215006, Jiangsu, China TEL: +86-512-6251-5088 / FAX: +86-512-6251-5098
COMPETENCES AND GUARANTEES
DEKRA is a testing laboratory competent to carry out the tests described in this report. In order to assure the traceability to other national and international laboratories, DEKRA has a calibration and maintenance program for its measurement equipment. DEKRA guarantees the reliability of the data presented in this report, which is the result of the measurements and the tests performed to the item under test on the date and under the conditions stated in the report and it is based on the knowledge and technical facilities available at DEKRA at the time of performance of the test. DEKRA is liable to the client for the maintenance of the confidentiality of all information related to the item under test and the results of the test. The results presented in this Test Report apply only to the particular item under test established in this document. IMPORTANT: No parts of this report may be reproduced or quoted out of context, in any form or by any means, except in full, without the previous written permission of DEKRA.

GENERAL CONDITIONS

Test Location Date(receive sample) Date (start test) Date (finish test)

No. 99, Hongye Road, Suzhou Industrial Park Suzhou, 215006, P.R. China Dec. 27, 2021 Jan. 19, 2022 Jan. 22, 2022

1. This report is only referred to the item that has undergone the test. 2. This report does not constitute or imply on its own an approval of the product by the Certification Bodies or
Competent Authorities. 3. This document is only valid if complete; no partial reproduction can be made without previous written permission
of DEKRA. 4. This test report cannot be used partially or in full for publicity and/or promotional purposes without previous
written permission of DEKRA.

ENVIRONMENTAL CONDITIONS

The climatic conditions during the tests are within the limits specified by the manufacturer for the operation of the EUT and the test equipment. The climatic conditions during the tests were within the following limits:

Ambient temperature Relative Humidity air

15 °C ­ 35 °C 30% - 60%

If explicitly required in the basic standard or applied product / product family standard the climatic values are recorded and documented separately in this test report.

Report no.: 2190851R-RF-US-P06V01

Page 4 / 31

DEKRA Testing and Certification (Suzhou) Co., Ltd. No.99 Hongye Rd., Suzhou Industrial Park, Suzhou, 215006, Jiangsu, China TEL: +86-512-6251-5088 / FAX: +86-512-6251-5098

POSSIBLE TEST CASE VERDICTS

Test case does not apply to test object Test object does meet requirement Test object does not meet requirement Not measured

N/A P (Pass) / PASS F (Fail) / FAIL N/M

ABBREVIATIONS

For the purposes of the present document, the following abbreviations apply:

EUT QP CAV AV CDN SAC OATS BW AM PM HCP VCP UN Tx Rx N/A N/M

: Equipment Under Test : Quasi-Peak : CISPR Average : Average : Coupling Decoupling Network : Semi-Anechoic Chamber : Open Area Test Site : Bandwidth : Amplitude Modulation : Pulse Modulation : Horizontal Coupling Plane : Vertical Coupling Plane : Nominal voltage : Transmitter : Receiver : Not Applicable : Not Measured

Report no.: 2190851R-RF-US-P06V01

Page 5 / 31

DEKRA Testing and Certification (Suzhou) Co., Ltd. No.99 Hongye Rd., Suzhou Industrial Park, Suzhou, 215006, Jiangsu, China TEL: +86-512-6251-5088 / FAX: +86-512-6251-5098

DOCUMENT HISTORY

Report No. 2190851R-RF-US-P06V01 2190851R-RF-US-P06V01

Version V1.0 V1.1

Description Initial issue of report. Modified frequency range

Issued Date 2022-02-09 2022-03-28

REMARKS AND COMMENTS
1. The equipment under test (EUT) does meet the essential requirements of the stated standard(s)/test(s). 2. These test results on a sample of the device are for the purpose of demonstrating Compliance with Part 15
Subpart C. 3. The measurement result is considered in conformance with the requirement if it is within the prescribed limit, It is
not necessary to account the uncertainty associated with the measurement result. 4. The test results presented in this report relate only to the object tested. 5. The test report shall not be reproduced without the written approval of DEKRA Testing and Certification (Suzhou)
Co., Ltd. 6. This report will not be used for social proof function in China market. 7. DEKRA declines any responsibility with the following test data provided by customer that may affect the validity of
result: - Chapter 1.1 General Description of the Item(s); - Chapter 1.2 Antenna Informaion; - Chapter 1.3 Channel List.

Report no.: 2190851R-RF-US-P06V01

Page 6 / 31

DEKRA Testing and Certification (Suzhou) Co., Ltd. No.99 Hongye Rd., Suzhou Industrial Park, Suzhou, 215006, Jiangsu, China TEL: +86-512-6251-5088 / FAX: +86-512-6251-5098

USED EQUIPMENT

AC Power Line Conducted Emission / TR1

Instrument EMI Test Receiver

Manufacturer R&S

Two-Line V-Network

R&S

Two-Line V-Network

R&S

Current Probe

R&S

50ohm Termination

SHX

50ohm Termination

SHX

50ohm Coaxial Switch

Anritsu

Temperature/Humidity Meter RTS

Coaxial Cable

Suhner

Coaxial Cable

Suhner

Dekra test software

Dekra

Model No. ESCI ENV216
ENV216 EZ-17 TF2 TF2 MP59B RTS-8S RG 223 RG 223 -

Serial No. 100906 101190 101044 100678 07081402 07081403 6200464462 TR1-TH TR1-C1 TR1-C2 -

Cal. Date 2021.03.20 2021.01.27 2021.03.20 2021.01.27
2021.09.22 2021.09.22 N/A
2021.08.12 2021.08.12 2021.08.12 -

Next Cal. Date 2022.03.19 2022.01.26 2022.03.19 2022.01.26 2022.09.21 2022.09.21 N/A 2022.08.11 2022.08.11 2022.08.11 -

Radiated Emission(30MHz-1GHz) / AC2

Instrument

Manufacturer

EMI Test Receiver

R&S

Bilog Antenna

Teseq GmbH

Temperature/Humidity Meter RTS

Coaxial Cable

Huber+Suhner

Dekra test software

Dekra

Model No. ESCI CBL6112D RTS-8S RG 214 -

Serial No. 100573 27611 AC2-TH AC2-C -

Cal. Date 2021.12.05
2021.08.18 2021.08.12 2021.03.31 -

Next Cal. Date 2022.12.04 2022.08.17 2022.08.11 2022.03.30 -

Report no.: 2190851R-RF-US-P06V01

Page 7 / 31

DEKRA Testing and Certification (Suzhou) Co., Ltd. No.99 Hongye Rd., Suzhou Industrial Park, Suzhou, 215006, Jiangsu, China TEL: +86-512-6251-5088 / FAX: +86-512-6251-5098

UNCERTAINTY

Uncertainties have been calculated according to the DEKRA internal document. The reported expanded uncertainties are based on a standard uncertainty multiplied by a coverage factor of k=2, providing a level of confidence of approximately 95% .

Test item AC Power Line Conducted Emission
Radiated Emission(30MHz~1GHz) Occupied Bandwidth

Uncertainty
9kHz~150kHz: 2.80dB 150kHz~30MHz: 2.40dB Horizontal: 30MHz~200MHz: 3.50 dB 300MHz~1GHz: 3.60 dB Vertical: 30MHz~200MHz: 3.60 dB 300MHz~1GHz: 3.50 dB
±150Hz

Report no.: 2190851R-RF-US-P06V01

Page 8 / 31

DEKRA Testing and Certification (Suzhou) Co., Ltd. No.99 Hongye Rd., Suzhou Industrial Park, Suzhou, 215006, Jiangsu, China TEL: +86-512-6251-5088 / FAX: +86-512-6251-5098

1 GENERAL INFORMATION

1.1 General Description of the Item(s)

Product Name.............................. : Model No. .................................... : Trademark ................................... : FCC ID ........................................ :
Manufacturer................................ : Manufacturer address .................. :

Wireless Charger WPC003-5 BCS 2AXPS-WPC003-5
BCS Automotive Interface Solutions(Suzhou)Co.,Ltd No.2052 Taidong Road Xiangcheng Economic Development District, 215413 Suzhou China

Operating Frequency Range ......... : Type of Modulation........................ : Number of Channel ....................... :
Operating Temperature Range...... :

110~300 kHz ASK 1 -40 ~ 85 

Rated power supply ...................: Mounting position.......................:

Voltage and Frequency
AC: 220 ­ 240 V, 50/60 Hz AC: 110 ­ 130 V, 50/60 Hz DC: 12 V Battery: 12 Vdc Table top equipment Wall/Ceiling mounted equipment Floor standing equipment Hand-held equipment Other: vehicle-mounted equipment

Report no.: 2190851R-RF-US-P06V01

Page 9 / 31

DEKRA Testing and Certification (Suzhou) Co., Ltd. No.99 Hongye Rd., Suzhou Industrial Park, Suzhou, 215006, Jiangsu, China TEL: +86-512-6251-5088 / FAX: +86-512-6251-5098

1.2 Antenna Information

Antenna model / type number........ : N/A

Antenna serial number .................. : N/A

Antenna Delivery .......................... :

1TX + 1RX

2TX + 2RX

Others:.........

Antenna technology....................... :

SISO

MIMO

Antenna Type................................ :

External

Internal

Antenna Gain ................................ : N/A

CDD Beam-forming Dipole Sectorized Ceramic Chip PIFA PCB Others: Coil antenna

Report no.: 2190851R-RF-US-P06V01

Page 10 / 31

DEKRA Testing and Certification (Suzhou) Co., Ltd. No.99 Hongye Rd., Suzhou Industrial Park, Suzhou, 215006, Jiangsu, China TEL: +86-512-6251-5088 / FAX: +86-512-6251-5098

1.3 Channel List

Working Frequency of Each Channel:

Channel Frequency

Channel

01

110.8 kHz

--

--

--

--

Frequency ---

Channel ---

Frequency ---

Channel ---

Frequency ---

Note: The General Description of the Item , antenna information and Channel List for the EUT in clause 1 are provided and confirmed by the client.

Report no.: 2190851R-RF-US-P06V01

Page 11 / 31

DEKRA Testing and Certification (Suzhou) Co., Ltd. No.99 Hongye Rd., Suzhou Industrial Park, Suzhou, 215006, Jiangsu, China TEL: +86-512-6251-5088 / FAX: +86-512-6251-5098

2 DESCRIPTION OF TEST SETUP

2.1 Operating mode(s) used for tests

During the tests the following operating mode(s) has(have) been used.

Test Mode For WPT

Mode 1: Transmit

2.2 Auxiliary equipment / Test software for the EUT

Auxiliary equipment N/A software N/A

Type / Version N/A Type / Version N/A

Manufacturer N/A Manufacturer N/A

Supplied by N/A Supplied by N/A

Report no.: 2190851R-RF-US-P06V01

Page 12 / 31

DEKRA Testing and Certification (Suzhou) Co., Ltd. No.99 Hongye Rd., Suzhou Industrial Park, Suzhou, 215006, Jiangsu, China TEL: +86-512-6251-5088 / FAX: +86-512-6251-5098
2.3 Test Configuration / Block diagram used for tests
Test setup Diagram- Radiated Test

Report no.: 2190851R-RF-US-P06V01

Page 13 / 31

DEKRA Testing and Certification (Suzhou) Co., Ltd. No.99 Hongye Rd., Suzhou Industrial Park, Suzhou, 215006, Jiangsu, China TEL: +86-512-6251-5088 / FAX: +86-512-6251-5098
2.4 Testing process
1 Setup the EUT as shown in Section 2.3. 2 Turn on the power of equipment. 3 Verify that the EUT works properly.

Report no.: 2190851R-RF-US-P06V01

Page 14 / 31

DEKRA Testing and Certification (Suzhou) Co., Ltd. No.99 Hongye Rd., Suzhou Industrial Park, Suzhou, 215006, Jiangsu, China TEL: +86-512-6251-5088 / FAX: +86-512-6251-5098

3 VERDICT SUMMARY SECTION
This chapter presents an overview of standards and results. Refer to the next chapters for details of measured test results and applied test levels.

3.1 Standards
Standard FCC CFR Title 47 Part 15 Subpart C ANSI C63.10

Year 2021
2013

Description Intentional Radiators
American National Standard of Procedures for Compliance Testing of Unlicensed Wireless Devices

3.2 Deviation(s) from the Standard(s) / Test Specification(s)
The following deviation(s) was / were made from the published requirements of the listed standards: N/A. (Please define the deviations from the standard(s) if applicable)

Report no.: 2190851R-RF-US-P06V01

Page 15 / 31

DEKRA Testing and Certification (Suzhou) Co., Ltd. No.99 Hongye Rd., Suzhou Industrial Park, Suzhou, 215006, Jiangsu, China TEL: +86-512-6251-5088 / FAX: +86-512-6251-5098

3.3 Overview of results

Requirement ­ Test case Conducted Emission Field Strength of Spurious Channel Bandwidth Antenna Requirement

Basic standard(s) FCC CFR Title 47 Part 15 Subpart C Section 15.207 FCC CFR Title 47 Part 15 Subpart C Section 15.209 FCC CFR Title 47 Part 15 Subpart C Section 15.215(c) FCC CFR Title 47 Part 15 Subpart C: Section 15.203

Verdict N/A
PASS PASS PASS

Remark ---------

Report no.: 2190851R-RF-US-P06V01

Page 16 / 31

DEKRA Testing and Certification (Suzhou) Co., Ltd. No.99 Hongye Rd., Suzhou Industrial Park, Suzhou, 215006, Jiangsu, China TEL: +86-512-6251-5088 / FAX: +86-512-6251-5098

3.4 Test Facility

USA

: FCC Designation Number: CN1199

Report no.: 2190851R-RF-US-P06V01

Page 17 / 31

DEKRA Testing and Certification (Suzhou) Co., Ltd. No.99 Hongye Rd., Suzhou Industrial Park, Suzhou, 215006, Jiangsu, China TEL: +86-512-6251-5088 / FAX: +86-512-6251-5098
4 TEST RESULTS 4.1 AC Power Line Conducted Emission

VERDICT: N/A

4.1.1 Limit

Standard

FCC Part 15 Subpart C Paragraph 15.207

Frequency range [MHz]

Limit: QP [dB(V)1)]

Limit: AV [dB(V) 1)]

0,15 - 0,50

66 ­ 56 2)

56 - 46 2)

0,50 - 5,0

56

46

5,0 - 30

60

50

1) At the transition frequency, the lower limit applies. 2) The limit decreases linearly with the logarithm of the frequency.
NOTE 1: The exclusion band for transmitters shall be considered for transmitters operating at frequencies below 30 MHz.
NOTE 2: Where the AC output port is directly connected (or via a circuit breaker) to the AC power input port of the EUT the AC power output port need not to be tested.

4.1.2 Test Setup

4.1.3 Test Procedure
References Rule ANSI C63.10-2013

Chapter 6.2

Item Standard test method for ac power-line conducted emissions from unlicensed wireless devices

Report no.: 2190851R-RF-US-P06V01

Page 18 / 31

DEKRA Testing and Certification (Suzhou) Co., Ltd. No.99 Hongye Rd., Suzhou Industrial Park, Suzhou, 215006, Jiangsu, China TEL: +86-512-6251-5088 / FAX: +86-512-6251-5098
4.1.4 Test Data
Note: The product is vehicle-mounted equipment and powered by DC, so that this item is not applicable.

Report no.: 2190851R-RF-US-P06V01

Page 19 / 31

DEKRA Testing and Certification (Suzhou) Co., Ltd. No.99 Hongye Rd., Suzhou Industrial Park, Suzhou, 215006, Jiangsu, China TEL: +86-512-6251-5088 / FAX: +86-512-6251-5098

4.2 Radiated emission

VERDICT: PASS

4.2.1 Limit
Standard

FCC Part 15 Subpart C Paragraph 15.209

Frequency (MHz)

Field strength (V/m)

Field strength (dBV/m)

Measurement distance (m)

0.009 - 0.49

2400/F(kHz)

48.5 ­ 13.8

300(Note 1)

0.49 - 1.705

24000/F(kHz)

33.8 - 23

30(Note 1)

1.705 - 30

30

29.5

30(Note 1)

30 - 88

100

40

3(Note 2)

88 - 216

150

43.5

3(Note 2)

216 - 960

200

46

3(Note 2)

Above 960

500

54

3(Note 2)

Note 1: The tighter limits apply at the band edges.

Note 2: Measurements were performed at 10m and the data was extrapolated to the specified measurement distance of 300m using the square of an inverse linear distance extrapolation factor (40 dB/decade) as specified in §15.31(f)(2). Extrapolation Factor = 40 log10(300/10) = 59dB for example.

Measurements were performed at 10m and the data was extrapolated to the specified measurement distance of 30m using the square of an inverse linear distance extrapolation factor (40 dB/decade) as specified in §15.31(f)(2). Extrapolation Factor = 40 log10(30/10) = 19dB for example.

Note 3: All measurements were performed using a loop antenna. The antenna was positioned in three orthogonal positions (X front, Y side, Z top) and the position with the highest emission level was recorded.

Report no.: 2190851R-RF-US-P06V01

Page 20 / 31

DEKRA Testing and Certification (Suzhou) Co., Ltd. No.99 Hongye Rd., Suzhou Industrial Park, Suzhou, 215006, Jiangsu, China TEL: +86-512-6251-5088 / FAX: +86-512-6251-5098
4.2.2 Test Setup
Below 30MHz Test Setup:
30MHz-1GHz Test Setup:

4.2.3 Test Procedure
References Rule ANSI C63.10
ANSI C63.10 ANSI C63.10
ANSI C63.10
ANSI C63.10
ANSI C63.10

Chapter 11.12 11.12.1 11.12.2.7 6.4
6.5
6.6

Description
Emissions in restricted frequency bands Radiated emission measurements Radiated spurious emission test Radiated emissions from unlicensed wireless devices below 30 MHz
Radiated emissions from unlicensed wireless devices in the frequency range of 30 MHz to 1000 MHz Radiated emissions from unlicensed wireless devices above 1 GHz

Report no.: 2190851R-RF-US-P06V01

Page 21 / 31

DEKRA Testing and Certification (Suzhou) Co., Ltd. No.99 Hongye Rd., Suzhou Industrial Park, Suzhou, 215006, Jiangsu, China TEL: +86-512-6251-5088 / FAX: +86-512-6251-5098

4.2.4 Test Data
Profile: 2190851R Engineer: Julius zhou Site: AC2 Limit: FCC_Part15.209_RE(3m) Probe: RF(0.009-30MHz) EUT: WPC003-5 Note: Mode 1

Page No.: 5
Time: 2022/01/21 - 18:10 Margin: 0 Polarity: Horizontal Power: DC 12V

No Mark

1

2

3

4

*

Frequency (MHz) 0.026 0.064 0.089 0.111

Measure Level (dBuV/m) 51.130 44.064 41.725 53.849

Reading Level (dBuV) 29.587 22.138 19.830 31.979

Over Limit (dB) -68.160 -67.407 -66.883 -52.841

Limit (dBuV/m)
119.290 111.471 108.608 106.690

Factor (dB)
21.544 21.926 21.895 21.870

Type
PK PK PK PK

Report no.: 2190851R-RF-US-P06V01

Page 22 / 31

DEKRA Testing and Certification (Suzhou) Co., Ltd. No.99 Hongye Rd., Suzhou Industrial Park, Suzhou, 215006, Jiangsu, China TEL: +86-512-6251-5088 / FAX: +86-512-6251-5098

Profile: 2190851R Engineer: Julius zhou Site: AC2 Limit: FCC_Part15.209_RE(3m) Probe: RF(0.009-30MHz) EUT: WPC003-5 Note: Mode 1

Page No.: 6
Time: 2022/01/21 - 18:12 Margin: 0 Polarity: Vertical Power: DC 12V

No Mark
1 2 3 4 *

Frequency (MHz) 0.026 0.064 0.089 0.111

Measure Level (dBuV/m) 48.120 42.813 37.085 53.369

Reading Level (dBuV) 27.077 21.387 15.690 31.999

Over Limit (dB) -71.170 -68.658 -71.523 -53.321

Limit (dBuV/m)
119.290 111.471 108.608 106.690

Factor (dB)
21.044 21.426 21.395 21.370

Type
PK PK PK PK

Report no.: 2190851R-RF-US-P06V01

Page 23 / 31

DEKRA Testing and Certification (Suzhou) Co., Ltd. No.99 Hongye Rd., Suzhou Industrial Park, Suzhou, 215006, Jiangsu, China TEL: +86-512-6251-5088 / FAX: +86-512-6251-5098

Profile: 2190851R Engineer: Julius zhou Site: AC2 Limit: FCC_Part15.209_RE(3m) Probe: RF(0.009-30MHz) EUT: WPC003-5 Note: Mode 1

Page No.: 3
Time: 2022/01/21 - 19:38 Margin: 0 Polarity: Horizontal Power: DC 12V

No Mark
1 2 3 * 4

Frequency (MHz) 0.169 0.407 1.113 2.333

Measure Level (dBuV/m) 49.688 39.644 26.015 23.584

Reading Level (dBuV) 27.877 18.092 5.994 2.727

Over Limit (dB) -53.354 -55.767 -40.679 -45.916

Limit (dBuV/m)
103.041 95.411 66.694 69.500

Factor (dB)
21.811 21.552 20.021 20.857

Type
PK PK PK PK

Report no.: 2190851R-RF-US-P06V01

Page 24 / 31

DEKRA Testing and Certification (Suzhou) Co., Ltd. No.99 Hongye Rd., Suzhou Industrial Park, Suzhou, 215006, Jiangsu, China TEL: +86-512-6251-5088 / FAX: +86-512-6251-5098

Profile: 2190851R Engineer: Julius zhou Site: AC2 Limit: FCC_Part15.209_RE(3m) Probe: RF(0.009-30MHz) EUT: WPC003-5 Note: Mode 1

Page No.: 4
Time: 2022/01/21 - 18:09 Margin: 0 Polarity: Vertical Power: DC 12V

No Mark
1 2 3 * 4

Frequency (MHz) 0.169 0.422 1.075 2.363

Measure Level (dBuV/m) 50.290 39.200 26.079 24.789

Reading Level (dBuV) 28.979 18.163 6.596 4.431

Over Limit (dB) -52.752 -55.897 -40.916 -44.711

Limit (dBuV/m)
103.041 95.097 66.995 69.500

Factor (dB)
21.311 21.037 19.483 20.358

Type
PK PK PK PK

Report no.: 2190851R-RF-US-P06V01

Page 25 / 31

DEKRA Testing and Certification (Suzhou) Co., Ltd. No.99 Hongye Rd., Suzhou Industrial Park, Suzhou, 215006, Jiangsu, China TEL: +86-512-6251-5088 / FAX: +86-512-6251-5098

Profile: 2190851R Engineer: Julius zhou Site: AC2 Limit: FCC_Part15.209_RE(3m) Probe: AC2_3M(30-1000M) EUT: WPC003-5 Note: Mode 1

Page No.: 1
Time: 2022/01/21 - 09:04 Margin: 0 Polarity: Horizontal Power: DC 12V

No Mark
1 * 2

Frequency (MHz) 36.062 482.384

Measure Level (dBuV/m) 29.572 32.326

Reading Level (dBuV) 3.577 5.005

Over Limit (dB) -10.428 -13.674

Limit (dBuV/m)
40.000 46.000

Factor (dB)
25.996 27.320

Type
PK PK

Report no.: 2190851R-RF-US-P06V01

Page 26 / 31

DEKRA Testing and Certification (Suzhou) Co., Ltd. No.99 Hongye Rd., Suzhou Industrial Park, Suzhou, 215006, Jiangsu, China TEL: +86-512-6251-5088 / FAX: +86-512-6251-5098

Profile: 2190851R Engineer: Julius zhou Site: AC2 Limit: FCC_Part15.209_RE(3m) Probe: AC2_3M(30-1000M) EUT: WPC003-5 Note: Mode 1

Page No.: 2
Time: 2022/01/21 - 18:48 Margin: 0 Polarity: Vertical Power: DC 12V

No Mark
1 2 *

Frequency (MHz) 250.190 413.999

Measure Level (dBuV/m) 28.344 28.695

Reading Level (dBuV) 3.881 2.922

Over Limit (dB) -17.656 -17.305

Limit (dBuV/m)
46.000 46.000

Factor (dB)
24.463 25.772

Type
PK PK

Note 1: The final result only applies for using QP detector, if the pre-test result on peak is lower than limit, then QP measurement needn't be performed. Note 2: " * ", means this data is the worst emission level. Note 3: Measurement Level = Reading Level + Factor(Probe+Cable-Amp). Note 4: The orthogonal orientations (x/y/z) of the shielded loop antenna are evaluated, shown in the report is the worst data.

Report no.: 2190851R-RF-US-P06V01

Page 27 / 31

DEKRA Testing and Certification (Suzhou) Co., Ltd. No.99 Hongye Rd., Suzhou Industrial Park, Suzhou, 215006, Jiangsu, China TEL: +86-512-6251-5088 / FAX: +86-512-6251-5098

4.3 20dB Bandwidth

VERDICT: PASS

4.3.1 Limit

Standard

FCC Part 15 Subpart C

Intentional radiators operating under the alternative provisions to the general emission limits, as contained in §§15.215(c), must be designed to ensure that the 20 dB bandwidth of the emission, or whatever bandwidth may otherwise be specified in the specific rule section under which the equipment operates, is contained within the frequency band designated in the rule section under which the equipment is operated.

4.3.2 Test Setup

4.3.3 Test Procedure
The bandwidth of the fundamental frequency was measured by spectrum analyzer with the RBW 1%~5% of 20dBc bandwidth and the VBW three times of the RBW. The 20dB bandwidth is defined as the total spectrum the power of which is higher than peak power minus 20dB.

Report no.: 2190851R-RF-US-P06V01

Page 28 / 31

DEKRA Testing and Certification (Suzhou) Co., Ltd. No.99 Hongye Rd., Suzhou Industrial Park, Suzhou, 215006, Jiangsu, China TEL: +86-512-6251-5088 / FAX: +86-512-6251-5098

4.3.4 Test Data

Mode 1

Test Freq. (kHz)
110.6

20dB Occupied Bandwidth (kHz)
929

99% Occupied Bandwidth (kHz)
691

Result Pass

Report no.: 2190851R-RF-US-P06V01

Page 29 / 31

DEKRA Testing and Certification (Suzhou) Co., Ltd. No.99 Hongye Rd., Suzhou Industrial Park, Suzhou, 215006, Jiangsu, China TEL: +86-512-6251-5088 / FAX: +86-512-6251-5098

4.4 Antenna Requirement

VERDICT: PASS

4.4.1 Limit:

Standard

FCC Part 15 Subpart C Paragraph 15.203

An intentional radiator shall be designed to ensure that no antenna other than that furnished by the responsibby LE

party shall be used with the device. The use of a permanently attached antenna or of an antenna that uses a unique

coupling to the intentional radiator shall be considered sufficient to comply with the provisions of this section. The

manufacturer may design the unit so that a broken antenna can be replaced by the user, but the use of a standard

antenna jack or eby LEctrical connector is prohibited. This requirement does not apply to carrier current devices or to

devices operated under the provisions of §15.211, §15.213, §15.217, §15.219, or §15.221. Further, this requirement

does not apply to intentional radiators that must be professionally instalby LEd, such as perimeter protection systems

and some field disturbance sensors, or to other intentional radiators which, in accordance with §15.31(d), must be

measured at the installation site. However, the instalby LEr shall be responsibby LE for ensuring that the proper

antenna is employed so that the limits in this part are not exceeded.

4.4.2 Antenna Connector Construction:
The use of a permanently attached antenna The antenna use of a unique coupling to the intentional radiator The use of a nonstandard antenna jack or eby LEctrical connector Pby LEase refer to the attached document "Internal Photograph" to show the antenna connector.

Report no.: 2190851R-RF-US-P06V01

Page 30 / 31

DEKRA Testing and Certification (Suzhou) Co., Ltd. No.99 Hongye Rd., Suzhou Industrial Park, Suzhou, 215006, Jiangsu, China TEL: +86-512-6251-5088 / FAX: +86-512-6251-5098
5 TEST SETUP PHOTO AND EUT PHOTO
Remark: The test setup photo and EUT Photo pby LEase see appendix.
The End

Report no.: 2190851R-RF-US-P06V01

Page 31 / 31



Related FCC IDs: