TEST & MEASUREMENT INSTRUMENTS VOLUME 23
Not Your Device? Search For Manuals or Datasheets below:
File Info : application/pdf, 142 Pages, 15.70MB
Document DEVICE REPORT
✖
TEST & MEASUREMENT INSTRUMENTS Cable Testers Clamp-On Meters Current Measurement Probes Data Loggers Digital Multimeters Electrical Test Tools Environmental Testers Ground Resistance Testers Leakage Current Meters & Probes Megohmmeters Micro-Ohmmeters Oscilloscopes Power Quality / Energy Analyzers, Meters & Loggers Test and Measurement (Lab) Instruments Thermal Imaging Cameras Transformer Ratiometers VOLUME 23 WWW.AEMC.COM TECHNICAL HOTLINE: (800) 343-1391 OVER 130 YEARS DEVELOPING ELECTRICAL TEST AND MEASUREMENT INSTRUMENTS HOW TO ORDER All AEMC® Instruments products are available through a network of authorized electrical, electronic and instrumentation distributors. For a list of authorized distributors in your state (US) or country (International), contact AEMC® Instruments or search on the "Where to Buy" tab of our website www.aemc.com CONTACT SALES & MARKETING 15 Faraday Drive Dover, NH 03820 USA (603) 749-6434 · Fax (603) 742-2346 Technical Hotline: (800) 343-1391 [email protected] · [email protected] · www.aemc.com ORDERING INFORMATION (WITHIN NORTH AMERICA) Chauvin Arnoux®, Inc., d.b.a. AEMC® Instruments 15 Faraday Drive Dover, NH 03820 USA (800) 343-1391 ext. 361 · Fax (603) 742-2346 [email protected] EXPORT DEPARTMENT (ALL COUNTRIES OTHER THAN USA & CANADA) Tel: +1 (603) 749-6434 ext. 520 Fax: +1 (603) 742-2346 [email protected] WHEN ORDERING PLEASE USE THE CATALOG NUMBER AND PRODUCT DESCRIPTION Example: QUANTITY CATALOG # DESCRIPTION 1 2137.52 Power & Energy Logger Model PEL 103 (W/LCD, w/3 MA193-10-BK Sensors) PRICE LIST A price list is available. Contact your AEMC® Instruments distributor or AEMC® Instruments directly for an up-to-date copy. AEMC® Instruments reserves the right to discontinue models at any time, or change specifications, price or design without notice and without incurring any obligation. Please contact us, your district sales engineer or distributor for updates. CHAUVIN ARNOUX®, INC. D.B.A. AEMC® INSTRUMENTS 950.CAT-MASTER-VOL23 Printed in the USA Rev.00 02/2023 FIND MORE AT: WWW.AEMC.COM TABLE OF CONTENTS Product Lines Cable Testers ................................................................................. 3 Clamp-On Meters........................................................................... 7 Current Measurement Probes ..................................................... 15 Data Loggers................................................................................ 35 Digital Multimeters...................................................................... 43 Electrical Test Tools..................................................................... 49 Environmental Testers................................................................. 55 Ground Resistance Testers.......................................................... 65 Leakage Current Meters & Probes.............................................. 79 Megohmmeters............................................................................ 83 Micro-Ohmmeters........................................................................ 95 Oscilloscopes............................................................................... 99 Power Quality / Energy Analyzers, Meters & Loggers .............. 107 Test and Measurement (Lab) Instruments................................ 123 Installation Testers .................................................................... 125 Thermal Imaging Cameras........................................................ 127 Transformer Ratiometers .......................................................... 131 Additional Resources DataView® Software.................................................................. 133 Training Seminars...................................................................... 138 COMPANY PROFILE AEMC® Instruments, with US operations in Dover - New Hampshire, began operations in 1976 in downtown Boston - Massachusetts. As a legal entity, AEMC® Instruments is Chauvin Arnoux®, Inc. d.b.a. AEMC® Instruments, and is affiliated with Chauvin Arnoux S.A.S. (Asnieres - France), founded in 1893 and still today a leader in the test and measurement instrument industry. Our products are backed by over 130 years of experien ce in test and measurement instruments, and encompass the latest international standards for quality and safety. AEMC® Instruments manufactures professional electrical test and measurement instruments for the industrial, commercial and utility marketplace. Product reliability, excellent customer support and expert technical assistance are our top priorities. AEMC® Instruments is the worldwide industry leading manufacturer of current measurement probes and is an industry leader in ground resistance testers, insulation resistance testers, and power/energy quality analyzers, meters and loggers. Our full product line also includes clamp-on meters, ratiometers, power meters, harmonic power meters, data loggers, thermal imagers, lightmeters, oscilloscopes, micro-ohmmeters and numerous other electrical test tools. Our Megohmmeter line finds its roots in the early 1900s when Chauvin Arnoux® introduced its first model made from a galvanometer and a decade resistance box combined with a DC power source. Today, AEMC® Instruments megohmmeters are digital and incorporate many intelligent features. Timers, alarms and variable test voltages are standard features. AEMC® Instruments has introduced a unique line of professional 1000, 5000, 10,000, and 15,000 volt megohmmeters with added features, such as: data storage; automated tests and results (internal calculations of DAR, PI, DD and other factors); PC Control; and report compliant software. Our Ground Tester line finds its roots in the early 1930s. A null balance galvanometer, a decade resistance box and a DC power source combined to make one of the first ground testers on the market. Over 20 years ago, AEMC® Instruments revolutionized the ground testing market by offering clamp-on ground resistance testers, eliminating the need to disconnect the system to test it and the need for auxiliary rods to perform the test. Several generations of improvements and additional features have strengthened AEMC® Instruments position as the industry standard and leader in clamp-on ground resistance testers. We again led the way in fall-of-potential ground testing with the introduction of an automatic tester in 2006 that automatically locked onto the optimum frequency to test and calculated all the test results for soil resistivity, ground resistance earth coupling and bond resistance, as well as stored the test data and generated computer reports including fall-of-potential plots. Our tower test system, again, is an innovative design providing the ability to test tower grounding systems without de-energizing them or removing the overhead ground conductor, saving considerable time and money and improving operator safety. We also manufacture and sell a wide variety of Power and Power Quality measuring instruments ranging from clamp-on meters to single and three-phase power quality analyzers and digital power meters. Our Power & Energy Loggers (PEL) can be used to monitor your power and energy usage and costs locally or from anywhere in the world! AEMC's DataView® software, designed to configure instruments, run tests, download and store results, and generate final reports was added to the product offering in late the 1990s. Today DataView® is compatible with our Megohmmeters, Ground Resistance Testers, Micro-Ohmmeters, Power Quality Analyzers, Data Loggers and Multi-meters, thus offering a standard for interface and control to all its products, eliminating the need to learn new software every time. Additionally, tablet and Smartphone Apps based on the AndroidTM platform are now available free of charge for our power, ground and clamp-on products. Additionally some products incorporate a remote web server connection for universal communication, regardless of smart device type. In addition to our product offering AEMC® Instruments offers a oneday accredited course in 'Understanding Ground Resistance Testing' and in 'Understanding Insulation Resistance Testing'. We also offer a 3-day comprehensive class in 'Understanding Power Quality Training'. Completing any of these three courses will give the student all the information they need to conduct resistance testing or power quality analyzing, safely, correctly and efficiently, as well as saving substantial time and money in the future. We also offer technical training online webinar seminars in ground resistance testing and insulation testing. Finally, we offer private classes that can be designed and customized to your specific needs. Our corporate office comprised of sales, marketing, exports, engineering, production, technical support, product service and NIST calibration is located in Dover, NH. AEMC® Instruments products can be purchased through a worldwide network of distributors who can be found on our website at www.aemc. com. We also offer custom products on an OEM basis. Visit our website at www.aemc.com to obtain information on our products and services and to get detailed information on attending our seminars. AEMC® Instruments prides itself as being your primary source for test and measurement instruments and training. Android is a trademark of Google LLC. The Android robot is reproduced or modified from work created and shared by Google and used according to terms described in the Creative Commons 3.0 Attribution License CABLE TESTERS SEE WEBSITE FOR PRICING AND AVAILABILITY: WWW.AEMC.COM CABLE TESTERS CABLE LOCATOR MODEL 6681 Detects and locates faults in electrical cables, telecommunication cables, live and de-energized conductors buried or in walls SPECIFICATIONS MODEL Display Output Signal Frequency External Voltage Measurement Range Functions Power Supply Dimension Weight Electrical Safety 6681 (TRANSMITTER) LCD screen with display of functions and bargraph 125 kHz (12 to 300) VAC/DC Digital coding of signals for easy signal identification, selection of transmission signal code, flashlight 9 V battery (7.48 x 3.5 x 1.67) in (190 x 89 x 42.5) mm 15 oz (425 g) with battery 300 V CAT III MODEL Display Detection Depth Single and Pole Application Two and Pole Application Single Loopback Line Line Voltage Detection Functions Power Supply Dimension Weight Safety Rating Consult factory for NIST Calibration prices 6681 (RECEIVER) Backlit LCD with display of functions and bargraph, transmission code, receiver and transmitter battery-charge status (0 to 6) ft (0 to 2) m (0 to 1.6) ft (0 to 0.5) m Up to 8.2 ft (2.5 m) Approximately (0 to 1.3) ft (0 to 0.4) m Automatic shutdown, automatic or manual adjustment of reception sensitivity, flashlight (6) 1.5 V AAA batteries (9.5 x 3.07 x 1.5) in (241.5 x 78 x 38) mm 12 oz (340 g) with battery 300 V CAT III PRODUCT INCLUDES Soft carrying case, set of (2) color-coded (red/black) leads w/4 mm banana plugs {1000 V CAT III}, set of (2) color-coded (red/black) alligator clips {1000 V CAT II}, adapter-110 V outlet w/ banana plugs, mini ground rod, 9 V battery, (6) AAA batteries and user manual. RECEIVER TRANSMITTER Flashlight FEATURES · Operates in both single and two-pole modes · Locates and traces hidden cables · Detects and locates line breaks · Detects faults in floor radiant heating systems · Detects constricted sections of non-metallic pipes · Detects circuit breakers/fuses · Detects short circuits · Backlight and flashlight functions · Compliant with standards electrical safety standard EN 61010-1 and electromagnetic compatibility standard EN 61326-1 CATALOG NO. 2127.85 DESCRIPTION Cable Locator Model 6681 4 www.aemc.com Technical Assistance (800) 343-1391 © Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved. Vol. 23 Rev.00 02/2023 CABLE TESTERS FAULT MAPPER MODEL CA7027 Maps and pinpoints the locations of faults on power and communication cables SPECIFICATIONS MODEL MEASUREMENTS Range @ Vp = 70 % Range Selection Resolution Accuracy Minimum Cable Length Cable Library CA7027 (23, 49, 98, 197, 394, 820, 1640, 3280, 6560, 9850, 19,000) ft Manual range control Approximately 1 % of selected range ± 1 % of range 1.5 ft (0.5 m) Sensitivity Velocity of Propagation (Vp) Output Pulse Output Pulse Width Scan Rate Output Impedance Display Resolution Tone Generator Voltage Warning Power Supply Auto Power OFF Weight Minimum 3 pixel return on a fault at 4 km on 0.6 mm 0, PE, TP Adjustable from (1 to 99) % + 5 V peak to peak into an open circuit 3 ns to 3 ms, Automatic with range 2 scans / second or scan held Selectable between (25, 50, 75 & 100) 128 x 64 pixel graphical LCD Oscillating (810 to 1110) Hz (4) 1.5 V AA alkaline batteries Selectable (1, 2, 3, 5) min or disabled 12 oz (340 g) PRODUCT INCLUDES MODEL CA7027 Soft carrying case, set of (2) color-coded (red/black) leads, test probes, alligator clips, (4) 1.5 V AA batteries and user manual. CA7027 Fault Mapper Pro® Telephone Cable Tester / Graphical TDR IP 54 Rated FEATURES · Built-in tone generator for tracing and locating cables · Large high-visibility blue electroluminescent backlit display · Compatible with industry standard Tone Receivers · Works on de-energized conductors · 11 range scales indicating cable faults and terminations up to 19,000 ft (58 00 m) in feet or meters · Unique graphical and digital display of fault information and length · Detects opens, shorts, taps, faulty taps, bridge taps, splitters, high resistance, wet cables, splices and more · Identifies impedance mismatches · Works with twisted pair, parallel and coaxial cable · Dead band less than 9 ft · Selectable cable impedance (25, 50, 75, 100) · Over-voltage protection up to 250 V · Adjustable cursor assists in locating faults and termination CATALOG NO. 2127.84 DESCRIPTION Fault Mapper Pro® Model CA7027 (Telephone / Cable Tester / Graphical TDR) Vol. 23 Rev.00 02/2023 Technical Assistance (800) 343-1391 © Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved. www.aemc.com 5 As a business of the Chauvin Arnoux® Group, our products are backed by over 130 years of experience and excellence in test and measurement instruments. We are the brand you can trust! CLAMP-ON METERS DATA ANALYSIS AND REPORTING SOFTWARE SEE PAGE 133 FOR MORE INFO ON DATAVIEW® SOFTWARE CONFIGURE CLAMP-ON METERS MODELS 407, 607 Download and store recorded data / Use included default report templates or create custom templates / Print reports of all test results SEE WEBSITE FOR PRICING AND AVAILABILITY: WWW.AEMC.COM CLAMP-ON METERS 200, 400 & 600 SERIES GENERAL PURPOSE METERS MODELS 403/603 & 205/405 Users can be sure of working in a higher degree of safety with 1000 V CAT IV rated meters (model dependent) SPECIFICATIONS MODELS 403/603 TRMS 205/405 TRMS ELECTRICAL Current AC (rms) (600 / 1000) A Current DC (900 / 1500) A Current AC+DC Voltage AC (rms) Voltage DC Voltage AC+DC Ohms Continuity (Buzzer) Diode Test THD Single- and 3-Phase Real Power (AC, DC, AC/DC)* Single- and 3-Phase Reactive Power (AC, DC, AC/DC)* Single- and 3-Phase Apparent Power (AC, DC, AC/DC)* Temperature (int., ext., °C, °F) Voltage Frequency Current Frequency Power Factor THD-r / THD-f Current Probe Adapter Function (AC/DC) Phase Rotation Auto AC/DC Auto Power OFF Hold Button Backlight Button Min/Max Button True InRush® Function Relative Function Peak ± Function Hz Button (900 / 1500) A (1000 / 1000) V (1000 / 1000) V (1000 / 1000) V (60 / 100) k Yes (< 40 ) Yes Yes (model 405) (600 / 1000) kW (600 / 1000) kvar (600 / 1000) kVA Yes 20 kHz (3 / 2 / 1) kHz Yes Yes / Yes (0 to 10) V Yes (2 wire) Yes (V & A) Yes Yes Yes Yes Yes Yes Yes Yes *Three-phase measurements assume balanced load Consult factory for NIST Calibration prices 403 603 205 405 * *205 only IP 40 FEATURES · 1000 V CAT IV Rated (Models 403, 603 & 405) · UL 94 VI flame retardant self-extinguishing · 10,000-count (400 & 600 series) and 6000 count (200 series) blue electroluminescent backlit display · Measures up to 1000 VAC (1400 V peak), 1000 VDC and AC+DC with resolution to 10 mV · Measures up to 2000 AAC and 3000 ADC (Model dependent) · Measures W, VA, var and PF for single- and three- phase balanced systems (Models 205 & 405) · Measures frequency to 20 kHz with 0.1 Hz resolution · Auto selects AC or DC measurement voltage · True InRush® current measurement with 100 mS capture · Jaw opening up to: 1.34 in (34 mm) (200 series), 1.89 in (48 mm) (400 series), 2.36 in (60 mm) (600 series) · K-thermocouple and adapter included (Models 403 & 603) PRODUCT INCLUDES Catalog #2139.21, #2139.31 Includes set of (2) color-coded silicone insulated test leads, test probes and alligator clips, K-thermocouple with 4 mm integrated adapter, soft carrying case, (4) 1.5 V AA batteries, and user manual. Catalog #2139.40 Includes set of (2) 5 ft (1.5 m) needle tip color-coded leads with 4 mm right angle plug, soft carrying case, (1) 9 V battery and user manual. Catalog #2139.50 Includes set of (2) color-coded silicone insulated test leads, test probes and alligator clips, soft carrying case, (4) 1.5 V AA batteries and user manual CATALOG NO. DESCRIPTION 2139.21 Clamp-On Meter Model 403 (TRMS, 1000 VAC/DC, 1000 AAC/1500 ADC, Ohms, Continuity, Temperature) 2139.31 2139.40 Clamp-On Meter Model 603 (TRMS, 1000 VAC/DC, 2000 AAC/3000 ADC, Ohms, Continuity, Temperature) Power Clamp-On Meter Model 205 (TRMS, 1000 VAC/DC, 600 AAC/900 ADC, Ohms, Continuity, Phase Rotation, Power, THD) 2139.50 Power Clamp-On Meter Model 405 (TRMS, 1000 VAC/DC, 1000 AAC/1500 ADC, Phase Rotation, Ohms, Continuity, Power, THD) 8 www.aemc.com Technical Assistance (800) 343-1391 © Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved. Vol. 23 Rev.00 02/2023 CLAMP-ON METERS 400 & 600 SERIES BLUETOOTH EDITION POWER AND HARMONIC METERS MODELS 407 & 607 Now available with AndroidTM mobile application SPECIFICATIONS MODELS 407 TRMS 607 TRMS ELECTRICAL Current AC (rms) 1000 A 2000 A Current DC 1500 A 3000 A Current AC+DC 1500 A Peak 3000 A Peak Voltage AC (rms) 1000 V Voltage DC 1000 V Voltage AC+DC 1000 V Ohms 100 k Continuity (Buzzer) Yes (< 40 ) Total Harmonic Distortion Yes Individual Harmonics (to 25th) Yes Single- and 3-Phase Real Power (AC, DC, AC/DC)* 1000 kW Single- and 3-Phase Reactive Power (AC, DC, AC/DC)* 1000 kvar 2000 kvar Single- and 3-Phase Apparent Power (AC, DC, AC/DC)* 1000 kVA 2000 kVA Voltage Frequency 20 kHz Current Frequency 2 kHz 1 kHz Power Factor Yes THD-r / THD-f Yes / Yes Auto AC/DC Yes (V & A) Auto Power OFF Yes Hold Button Yes Backlight Button Yes Min/Max Button Yes True InRush® Function Yes Peak ± Function Yes Harmonics Function Yes Rec (Record) Function Yes Wireless BT (Bluetooth) Function Yes Record (Recordings) 1000 Hz Button Yes *Three-phase measurements assume balanced load Consult factory for NIST Calibration prices 407 607 IP 40 FEATURES · 1000 V CAT IV Rated · UL 94 VI flame retardant self-extinguishing · 10,000-count blue electroluminescent backlit display · Measures up to 1000 VAC (1400 V peak), 1000 VDC and AC+DC with resolution to 10 mV · Measures up to 2000 AAC and 3000 AAC (Model 607) · Measures single- and three-phase power (real, reactive and apparent) up to 3 MW with resolution to 1 W · Measures frequency to 20 kHz with 0.1 Hz resolution · Auto selects AC or DC measurement · True InRush® current measurement with 100 mS capture · Measures harmonics up to the 25th · Records up to 1000 measurements · Bluetooth communication (communicates up to 30 ft) · Includes FREE DataView® software for download and report generation · Jaw opening up to 1.89 in (48 mm) (400 series) 2.36 in (60 mm) (600 series) PRODUCT INCLUDES Hard carrying case, set of (2) color-coded silicone test leads, test probes and alligator clips, Bluetooth USB adapter, (4) 1.5 V AA batteries, safety information sheet, and USB drive supplied with DataView® software and user manual. CATALOG NO. DESCRIPTION 2139.51 Power Clamp-On Meter Model 407 (TRMS, 1000 VAC/DC, 1000 AAC/1500 ADC, Ohms, Continuity, Energy, Harmonics, Power, THD, Recording) 2139.61 Power Clamp-On Meter Model 607 (TRMS, 1000 VAC/DC, 2000 AAC/3000 ADC, Ohms, Continuity, Energy, Harmonics, Power, THD, Recording) Vol. 23 Rev.00 02/2023 Technical Assistance (800) 343-1391 © Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved. www.aemc.com 9 CLAMP-ON METERS 500 SERIES MODEL 505 Small compact size clamp-on meter that fits comfortably in a tool bag SPECIFICATIONS MODEL ELECTRICAL AC Current (Auto-Ranging) Resolution AC Voltage (Auto-Ranging) Resolution Input Impedance DC Current (Auto-Ranging) Resolution DC Voltage (Auto-Ranging) Resolution Input Impedance Resistance Max Test Voltage Continuity Max Test Voltage Zero Mode / Delta Function Peak + / - Function MECHANICAL Dimensions Weight Jaw Opening Power Supply Battery Life ENVIRONMENTAL Operating Temperature Storage Temperature Operating Humidity Pollution Degree SAFETY Safety Standards Consult factory for NIST Calibration prices 505 (0.05 to 400) A (0.01 and 0.1) A (0.5 to 600) V (0.1 and 1) V 10 M (0.10 to 400) A (0.01 and 0.1) A (0.2 to 600) V (0.1 and 1) V 10 M (0.2 to 600) 1.5 VDC < 35 1.5 VDC Yes Yes / No (7.83 x 2.95 x 1.42) in (199 x 75 x 36) mm 8.57 oz. (243 g) with batteries 1.18 in (30 mm) (2) AAA, IEC LR3 (included) 40 h (+32 to 104) °F (0 to 40) °C (+14 to 140) °F (-10 to 60) °C < 70 % 2 EN/IEC 61010 to 600 V CAT III Jaw Opening: 1.18 in (30 mm) Conductor Size: 500 kcmil cable FEATURES · Compact size - fits into your pocket · 400 AAC or 400 AAC/DC current measurements · 600 VAC/DC volts measurements · Resistance measurements to 600 · Continuity with beeper below 35 · Hold function to "freeze" readings · Push-button for easy ADC zeroing · Large, easy-to-read 6000-cts LCD Display · 42-segment analog bar graph · Includes test leads and soft carrying pouch PRODUCT INCLUDES Soft carrying case, set of (2) color-coded (red/black) test leads with probe tips, (2) 1.5 V AAA batteries and user manual. CATALOG NO. 2139.82 DESCRIPTION Clamp-On Meter Model 505 (TRMS, AC/DC, 400 AAC/DC, 600 VAC/DC, Ohms, Continuity) RATED 600 V CAT III 10 www.aemc.com Technical Assistance (800) 343-1391 © Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved. Vol. 23 Rev.00 02/2023 CLAMP-ON METERS 500 SERIES (CONTINUED) MODEL 514 Full ranges and compliance to international safety and quality standards ensure a professional and reliable tool SPECIFICATIONS MODELS 514 TRMS AC Current (Auto-Ranging) Resolution (0.05 to 1000) Arms (0.01, 0.1and 1) A AC Voltage (Auto-Ranging) Resolution Input Impedance DC Current (Auto-Ranging) Resolution DC Voltage (Auto-Ranging) (0.5 to 750) Vrms 0.1 V and 1 Vrms 10 M (1 to 1000) A 0.01 A, 0.1 A and 1 A (0.2 to 1000) V Resolution 0.1 V and 1 V Input Impedance Resistance 10 M (0.2 to 4000) Max Test Voltage Diode Test 3 VDC 1.7 mA Open Circuit Voltage 3 VDC Continuity < 40 Max Test Voltage 3 VDC Frequency (Auto-Ranging) CURRENT INPUT Range Min Input Signal VOLTAGE INPUT Range Min Input Signal Power Supply 4 kHz 10 kHz 4 kHz 10 kHz 4 kHz 10 kHz 4 kHz 10 kHz 1 Hz Resolution 10 Hz Resolution 2 Arms 5 Arms 1 Hz Resolution 10 Hz Resolution 5 Vrms 10 Vrms 9 V Alkaline battery (included) ENVIRONMENTAL Operating Temperature (*-14 to 122) °F (-25 to 50) °C, 80 % RH, non-condensing Consult factory for NIST Calibration prices *Note: If Model 514 is to be used below 32 °F (0 °C), we suggest that the battery be replaced to ensure proper results. Jaw Opening: 1.575 in (40 mm) Conductor Size: (1) 750 kcmil cable or (2) 350 kcmil cables 514 FEATURES · Standard size, full function clamp-on meter · 1000 AAC or 1000 AAC/DC current measurements · Measures up to 750 VAC and 1000 VDC · TRMS measurements · Resistance measurements to 4000 · Continuity with beeper below 40 · Frequency measurements from V and A · Diode test · 1 ms peak function for fast capture of signals · Hold function to freeze readings · Push-button for easy ADC zeroing · Large, easy-to-read, 4000-count LCD display · 42-segment analog bargraph · Includes test leads, soft carrying pouch and batteries PRODUCT INCLUDES Soft carrying case, set of (2) color-coded (red/black) test leads with probe tips, 9 V battery and user manual. CATALOG NO. 2117.70 DESCRIPTION Clamp-on Meter Model 514 (AC/DC, TRMS, 1000 AAC/DC, 750 VAC/1000 VDC, Hz, Ohms, Continuity) Vol. 23 Rev.00 02/2023 Technical Assistance (800) 343-1391 © Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved. www.aemc.com 11 CLAMP-ON METERS 100 AAC/DC LOW CURRENT MODEL CM605 For general industrial monitoring and troubleshooting SPECIFICATIONS MODEL ELECTRICAL AC Current Measurement Ranges Frequency Range DC Current (positive only) Measurement Ranges AC Volts Measurement Ranges Frequency Input Impedance DC Volts (positive only)* Measurement Ranges Input Impedance Resistance (Ohms) Measurement Ranges Test Voltage Continuity Measurement Ranges Resolution Test Voltage Analog Output Output Frequency Output Impedance Other Functions ADC Zero & Relative Function HOLD Function PEAK Function Auto-Ranging Over Range Auto Power OFF Low Battery Mechanical Max. Cable Diameter Max. Jaw Opening Power Supply Dimensions Weight CM605 2 Ranges: 10 A, 100 A (50 to 500) Hz 2 Ranges: 10 A, 100 A 600 Vrms (40 to 500) Hz 10 M 600 V 10 M 10 k (9999 ) < 3.0 VDC Buzzer < 100 ± 25 1 < 3.0 VDC 10 mV/AAC & ADC through front banana jacks (0 to 20) kHz @ ± 3 db 3 k, < 50 pF One touch push button to Zero ADC, or other readings. Relative function to compare two measurements. Holds A & V measurements when pressed (HOLD button) Captures PEAK (1 ms) V or A measurement when activated (PEAK Button) "AUTO" displayed on LCD "OL" displayed on LCD for all measurements Auto Power OFF after approx 10 min with Over-Ride Low Battery indication on LCD Ø 0.45 in (12 mm) Ø 0.60 in (15 mm) (2) 1.5 V AAA (LR03) batteries (included) (7.44 x 2.80 x 1.46) in (189 x 71 x 37) mm 6.5 oz (184 g) SAFETY Safety Rating IEC/EN 61010-1 and 2-032 600 V CAT II and 300 V CAT III Pollution Degree 2 Class 2 Double or reinforced insulation, CE mark *For negative measurement, add 2 cts to the accuracy Consult factory for NIST Calibration prices CATALOG NO. 7000.02 DESCRIPTION Clamp-on Meter Model CM605 (100 AAC/DC, Low Current) FEATURES · 10,000-count LCD display · 100 AAC/DC Ammeter with low 10 A range (1 mA resolution)* · Analog output in AAC/DC to data loggers, oscilloscopes and more · Tapered jaws for crowded wiring areas Jaw opening: Ø 0.60 in (15 mm) Cable diameter: Ø 0.45 in (12 mm) · 600 VAC/DC voltmeter · Auto-ranging and ADC zero push-button · Data HOLD and PEAK functions · Relative function to compare two measurements · Ohm range and continuity test with beeper · Auto Power OFF and low battery indicator · IEC/EN 61010 safety rated and CE mark · 600 Vrms overload protection PRODUCT INCLUDES Soft carrying case, set of (2) color-coded (red/black) test leads with probe tips, (2) 1.5 V AAA batteries and user manual. 12 www.aemc.com Technical Assistance (800) 343-1391 © Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved. Vol. 23 Rev.00 02/2023 CLAMP-ON METERS SELECTION GUIDE Models Catalog Number Type AC Current AC Voltage DC Current DC Voltage Resistance («) Continuity Frequency (Hz) Current Voltage 205 2139.40 AC/DC TRMS 600 A 1000 V 900 A 1000 V 60 k« < 40 « 3 kHz 20 kHz Jaw Size 1.34 in (34 mm) Dimensions (8.7 x 3.1 x 1.65) in 403 2139.21 AC/DC TRMS 1000 A 1000 V 1500 A 1000 V 100 k« < 40 « 2 kHz 20 kHz 1.89 in (48 mm) (10.7 x 3.6 x 1.6) in 405 2139.50 AC/DC TRMS 1000 A 1000 V 1500 A 1000 V 100 k« < 40 « 2 kHz 20 kHz 1.89 in (48 mm) (10.7 x 3.6 x 1.6) in 407 2139.51 AC/DC TRMS 1000 A 1000 V 1500 A 1000 V 100 k« < 40 « 2 kHz 20 kHz 1.89 in (48 mm) (10.7 x 3.6 x 1.6) in 603 2139.31 AC/DC TRMS 2000 A 1000 V 3000 A 1000 V 100 k« < 40 « 1 kHz 20 kHz 2.36 in (60 mm) (11.65 x 4.37 x 1.61) in 607 2139.61 AC/DC TRMS 2000 A 1000 V 3000 A 1000 V 100 k« < 40 « 1 kHz 20 kHz 2.36 in (60 mm) (11.65 x 4.37 x 1.61) in 505 2139.82 AC/DC TRMS 400 A 600 V 400 A 600 V 600 « < 35 « 400 Hz 400 Hz 1.18 in (30 mm) (7.83 x 2.95 x 1.42) in 514 2117.70 AC/DC TRMS 1000 A 750 V 1000 A 1000 V 4000 « < 40 « 10 kHz 10 kHz 1.58 in (40 mm) (9.53 x 2.60 x 1.42) in 566* 2139.83 AC TRMS 100 A 600 V 2 600 V 600 k« < 45 « 500 Hz 500 Hz 0.91 in (23 mm) (8.27 x 3.0 x 1.32) in CM605 7000.02 AC/DC 100 A 600 V 100 A 600 V 9999 « < 100 « 500 Hz 500 Hz *Model 566 can be found in the Leakage Current Meters & Probes on Page 80 Consult factory for NIST Calibration prices 0.60 in (15 mm) (7.95 x 2.76 x 1.33) in Vol. 23 Rev.00 02/2023 Technical Assistance (800) 343-1391 © Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved. www.aemc.com 13 We've got you covered. Our products encompass the latest international standards for quality and safety and our product warranties provide maximum equipment protection. We are the brand you can trust! CURRENT MEASUREMENT PROBES AEMC® INSTRUMENTS PROBES ARE UNIVERSAL! SEE WEBSITE FOR PRICING AND AVAILABILITY: WWW.AEMC.COM CURRENT MEASUREMENT PROBES MINIFLEX® SERIES HIGH FREQUENCY OSCILLOSCOPE COMPATIBLE MINIFLEX® PROBES A compact AC current measurement device composed of a flexible sensor, a BNC connector, and an electronic module designed to measure frequency response up to 1 MHz SPECIFICATIONS MODELS ELECTRICAL Current Range Measurement Range Accuracy Signal Output Frequency Range Influence of Conductor Positioning Influence of Conductor Positioning in Sensor Against Handle External Conductor Influence Power Supply MECHANICAL Sensor Diameter Sensor Length Max Conductor Size Connection Cable Length Drop Test Vibration Mechanical Shock Weatherproofing ENVIRONMENTAL Operating Temperature Range Storage Temperature Range Altitude SAFETY Safety Rating MF 300-10-2-10-HF MF 3000-14-1-1-HF 30 A / 300 A 3000 A (0.5 to 300) A (0.5 to 3000) A 1 % ± 300 mA 100 mV / 10 mV/A 1 mV/A 5 Hz to 1 MHz @ -3 db 1.5 % typical, 3 % max 4 % typical, 6 % max (35 to 40) db on contact 9 V Alkaline battery (6 LF22) Ø 0.2 in (5 mm) 10 in (254 mm) 14 in (355 mm) 2.75 in (70 mm) 3.93 in (100 mm) 6.5 ft (2 m) 15.75 in (400 mm) Per IEC 68-2-32 Per IEC 68-2-6 Per IEC 68-2-27 IP50 (14 to 131) °F (-10 to 55) °C (-40 to 158) °F (-40 to 70) °C Operating: (0 to 6562) ft (0 to 2000) m, working voltage derating above; Non-operating: (0 to 39,000) ft (0 to 12,000) m Housing: EN 61010 600 V CAT III, 300 V CAT IV Sensor: EN 61010 1000 V CAT III, 600 V CAT IV MF 300-10-2-10-HF (10 in probe) MF 3000-14-1-1-HF (14 in probe) SAFETY R ATIN G FEATURES · Measures from (0.5 to 3000) Arms · Accuracy ± 1 % of Reading ± 0.3 A · TRMS measurements when connected to a TRMS instrument · No core saturation or damage if overloaded · 9 V battery for typical 150 hours continuous operation · 1 MHz frequency response · Low phase shift for power measurements · Insensitive to DC, measures only AC component on AC + DC signals · Excellent linearity · Lightweight · Sensor is resistant to oils and aliphatic hydrocarbons · Perfect accessory for any BNC oscilloscope CATALOG NO. DESCRIPTION 2126.84 MiniFlex® 30/300 A, 10 in, 100 mV/10 mV/A High Frequency (for any BNC Oscilloscope) 2126.86 MiniFlex® 3000 A, 14 in, 1 mV/A High Frequency (for any BNC Oscilloscope) 16 www.aemc.com Technical Assistance (800) 343-1391 © Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved. Vol. 23 Rev.00 02/2023 CURRENT MEASUREMENT PROBES MINIFLEX® SERIES MODEL MA114 Provides a welcomed solution when accessing electrical conductors in tight places or clamping onto cable bundles SPECIFICATIONS MODEL MA114 ELECTRICAL Nominal Range 3 AAC; 30 AAC; 300 AAC; 3000 AAC Measurement Range 3 A Range: (0.5 to 3) AAC, 30 A Range: (2 to 30) AAC, 300 A Range: (5 to 300) AAC, 3000 A Range: (50 to 3000) AAC Transformation Ratio Voltage Output Output Signal 3 A Range: 1 V/A (1 mV/mA) (3 VAC @ 3 A), 30 A Range: 100 mV/A (3 VAC @ 30 A), 300 A Range: 10 mV/A (3 VAC @ 300 A), 3000 A Range: 1 mV/A (3 VAC @ 3000 A) Phase Shift 1 ° (0.5 ° typical) Overload 3 A Range: 4.5 A, 30 A Range: 45 A, 300 A Range: 450 A, 3000 A Range: 4500 A Frequency Range 3000 A Range: 10 Hz to 10 kHz, 3 A, 30 A, 300 A Range: 10 Hz to 20 kHz Load Impedance 1 M Working Voltage 600 Vrms (CAT IV), 1000 Vrms (CAT III) Power Supply Battery Life (2) 1.5 V AA batteries or LR6 alkaline, +5 VDC with Type B micro-USB 300 hours typical. Approximately 1,800 10-minute measurements. Output Termination 1.6 ft (0.5 m) lead with (2) 4 mm safety banana plugs MECHANICAL Sensor Length 14 in (35.6 cm) Cable Length 6.5 ft (2 m) Maximum Conductor Size Ø 3.93 in (10 cm) Dimensions (4.7 x 2.3 x 1.4) in (12 x 5.8 x 3.6) cm Weight Approximately 10.58 oz (300 g) ENVIRONMENTAL Operating Temperature (14 to 131) °F (-10 to 55) °C Storage Temperature (-40 to 158) °F (-40 to 70) °C Operating Relative Humidity (0 to 95) % RH @ 95 °F (35 °C) SAFETY Safety Rating IEC 61010-2-32 Type B, 1000 V CAT III, 600 V CAT IV, Pollution Degree 2 Electromagnetic Compatibility IEC 61326-1 Ingress Protection IP54 (electronic unit), IP67 (flexible sensor) Double Insulation Yes Consult factory for NIST Calibration prices SAFETY R ATIN G 3 AAC 1 mV/mA 30 AAC 100 mV/A IP 67 300 AAC 3000 AAC 10 mV/A 1 mV/A FEATURES · 14-inch flexible sensor capable of clamping around a 3.93 inch cable or bundle · Waterproof sensor rated to IP67 · User selectable ranges of (3, 30, 300 and 3000) Amps · 600 V CAT IV, 1000 V CAT III rated · Not affected by magnetic saturation, provides excellent linearity and low phase shift · Battery or USB powered for long term use · Red LED indicates overload condition · Positive click locking sensor eliminates disconnection errors · Banana plug termination compatible with multimeters, data loggers and other instruments CATALOG NO. 2153.41 DESCRIPTION MiniFlex® 14 in Model MA114 (3 A/1 mV/mA, 30 A/100 mV/A, 300 A/10 mV/A, 3000 A/1 mV/A) Vol. 23 Rev.00 02/2023 Technical Assistance (800) 343-1391 © Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved. www.aemc.com 17 CURRENT MEASUREMENT PROBES FLEXIBLE CURRENT PROBES AMPFLEX® FLEXIBLE CURRENT PROBES Flexible AC current probe composed of a flexible sensor and an electronic module SPECIFICATIONS MODELS MEASUREMENT OUTPUT RANGE SIGNAL SENSOR LENGTH MAX CONDUCTOR SIZE CATALOG NO. 300-24-2-10 30/300 A 100/10 mV/A 24 in (610 mm) 8 in (203 mm) 2112.88 300-120-2-10 30/3000 A 100/10 mV/A 120 in (3048 mm) 38 in (970 mm) 2113.39 1000-24-1-1 1000 A 1 mV/A 24 in (610 mm) 8 in (203 mm) 2112.39 1000-24-2-1 100 A /1000 A 10/1 mV/A 24 in (610 mm) 8 in (203 mm) 2112.98 1000-36-2-1 100/1000 A 10/1 mV/A 36 in (914 mm) 11 in (279 mm) 2113.00 3000-24-1-1 3000 A 1 mV/A 24 in (610 mm) 8 in (203 mm) 2112.46 3000-36-1-1 3000 A 1 mV/A 36 in (914 mm) 11 in (279 mm) 2112.48 3000-24-2-1 300 A /3000 A 10/1 mV/A 24 in (610 mm) 8 in (203 mm) 2113.05 3000-36-2-1 300/3000 A 10/1 mV/A 36 in (914 mm) 11 in (279 mm) 2112.00 3000-48-2-1 300/3000 A 10/1 mV/A 48 in (1219 mm) 15 in (381 mm) 2112.01 6000-36-2-0.1 600/6000 A 1/0.1 mV/A 36 in (914 mm) 11 in (279 mm) 2113.21 30000-24-2-0.1 3000/30,000 A 1/0.1 mV/A 24 in (610 mm) 8 in (203 mm) 2113.33 Consult factory for NIST Calibration prices. Consult factory for special offers and ranges/lengths not shown. Note: Output is safety shrouded 4 mm male banana plug. FLEXPROBE® FLEXIBLE CURRENT PROBE MODEL 24-3001 SAFETY R ATIN G FEATURES · Models ranging from (0.5 to 30,000) Arms · Accuracy ± 1 % of Reading · TRMS measurements when connected to a TRMS instrument · No core saturation or damage if overloaded · Over range LED for measurement circuitry · Waterproof sensor · 9 V Alkaline battery, typically provides 150 hours of continuous operation (battery included) · Shape memory for custom pre-shaping of sensor before use (no drooping) · Very high frequency response · Low phase shift for power measurements of < 1.3 °, 0.7 ° typical · Insensitive to DC, measures only AC component on DC + AC signals · Excellent linearity · Lightweight Low cost AC current measurement probe designed to plug into digital multimeters, oscilloscopes and power recorders SPECIFICATIONS MODEL ELECTRICAL Current Range Output Signal Three Position Slide Switch 10 mV/A 1 mV/A ON/OFF Power Supply MECHANICAL Maximum Conductor Size Sensor Length Cable Length Output Termination 24-3001 300 AAC / 3000 AAC mV output (4000 mV peak max) 5 A to 300 Arms 50 A to 3000 Arms 9 V Alkaline battery (included) 7.6 in (193 mm) 24 in ± 1 in (610 ± 25) mm 6.5 ft (2 m) Double insulated 14 in (356 mm) lead with safety banana plugs Consult factory for NIST Calibration prices CATALOG NO. DESCRIPTION 2120.81 FlexProbe® Model 24-3001 (Lead) FEATURES · 24-inch flexible sensor fits around conductors up to 7.6 inch in diameter · Dual measurement ranges of 300 A and 3000 AAC. · Read amperage directly on DMM display · mV output directly proportional to the AC current measured · Output is 10 mV/A on 300 A range and 1 mV/A on 3000 A range · Accuracy of ± 1 % of Reading ± 500 mA · 4 % influence of conductor position in jaw · Dual banana plug termination for direct input into DMMs · Flashing LED low battery indicator · 9 V Alkaline battery, provides typical 150 hours of continuous operation (battery included) SAFETY R ATIN G ACCESSORIES BANANA (FEMALE) BNC (MALE) (XM-BB) Catalog #2118.46 (optional for AmpFlex® & FlexProbe® Flexible Current Probes) 18 www.aemc.com Technical Assistance (800) 343-1391 © Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved. Vol. 23 Rev.00 02/2023 CURRENT MEASUREMENT PROBES DC/AC MICROPROBES AND CURRENT PROBES MD SERIES & K SERIES MD Series probes are rugged and designed for use on cables and bus bars MD301 K100 K Series small probes are designed for high accuracy measuring low currents SPECIFICATIONS MODEL MD301 ELECTRICAL Nominal Range Measurement Range Transformation Ratio 500 AAC (2 to 500) AAC Voltage output Output Signal 1 mV/A (0.5 VDC @ 500 A) Phase Shift 25 A 100 A 250 A 500 A 600 A Overload 700 A for 10 min Frequency Range (48 to 1000) Hz (error: add 2 % to the ref.) Load Impedance 100 k Working/Common Voltage 600 Vrms Output Termination Double-insulated 5 ft (1.5 m) lead with (2) 4 mm safety banana plugs MECHANICAL Jaw Opening 1.3 in (33 mm) Maximum Conductor Size 1.18 in (30 mm), Max Bus Bar size: (2.48 x 0.20) in (63 x 5) mm Dimensions (2.6 x 7.68 x 1.34) in (66 x 195 x 34) mm Weight 14.82 oz (420 g) Material Polycarbonate UL 94 ENVIRONMENTAL Operating Temperature (5 to 122) °F (-15 to 50) °C Storage Temperature (-40 to 185) °F (-40 to 85) °C SAFETY Electrical EN 61010-2-032 600 V CAT III, Pollution: 2; 300 V CAT IV, Pollution: 2 Electromagnetic Compatibility EN 50081-1 Class B; EN 50082-2 Electrostatic discharge IEC 1000-4-2; Radiated field IEC 1000-4-3; Fast transients IEC 1000-4-4; Magnetic field at (50/60) Hz IEC 1000-4-8 Consult factory for NIST Calibration prices CATALOG NO. DESCRIPTION 1201.07 AC Current Probe Model MD301 (500 A, 1 mVDC/AAC, Lead) 1200.67 DC/AC MicroProbe Model K100 (4.5 A, 1 mV/mA) 2111.73 DC/AC MicroProbe Model K110 (450 mA, 10 mV/mA) SPECIFICATIONS MODELS K100 K110 ELECTRICAL Current Range (0 to ± 4.5) ADC (0 to 3) Arms (0 to ± 450) mADC (0 to 300) mArms Output Signal 1 mV/mA 10 mV/mA Resolution DC: 50 µA typical, AC: 100 µA typical Output Noise < 100 µV, DC to 3 kHz Frequency Response Output Termination DC to 2 kHz (@ -3 dB sine) DC to 1.5 kHz (@ -3 dB sine) 5 ft (1.5 m) lead with (2) 4 mm safety banana plugs; standard ¾ in (19 mm) spacing Power Supply (1) 9 V Alkaline battery (included) Battery Life 20 hours Consult factory for NIST Calibration prices FEATURES MD SERIES · 500 A range with mA or mV output · Unique hook-shaped jaws that enable the user to pry into or hook onto cables · Maximum conductor size is (2 x 500) kcmil · Works as a traditional current transformer with ratio of 1000:1 · AC/DC outputs available K SERIES · Measures extremely low level DC from 100 µA · Outputs signal proportional to total current (DC + AC) · Low noise · Ultra-compact size and non-contact clamp-on convenience · Simple plug-in operation · Designed for use with digital multimeters and oscilloscopes · Accurate display of waveforms · No range or mode (AC/DC) switching required · Red LED indicates momentary or continuous overload · Green LED indicates power and battery condition ACCESSORIES Catalog #1017.45 Adapter 4 mm Non-insulated for Safety Leads Catalog #2118.46 Adapter - Banana (Female) BNC (Male) (XM-BB) 600 V CAT III Vol. 23 Rev.00 02/2023 Technical Assistance (800) 343-1391 © Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved. www.aemc.com 19 CURRENT MEASUREMENT PROBES SL SERIES AC/DC CURRENT PROBES SL SERIES Compact, long nose probes designed for accurate measurements of low currents with 10 mADC sensitivity, capable of measuring both AC and DC current SPECIFICATIONS MODELS ELECTRICAL Nominal Range Measurement Range Transformation Ratio Output Signal Phase Shift (DC to 65 Hz) 1 mV/mA Range 10 mV/mA Range 100 mV/mA Range Overload Frequency Range Load Impedance Working/Common Mode Voltage Output Termination MECHANICAL Operating Relative Humidity Maximum Conductor Size Dimensions Weight Material ENVIRONMENTAL Operating Temperature Storage Temperature SAFETY Electrical CE Mark UL Approval Consult factory for NIST Calibration prices SL261 10 A; 100 AAC/DC peak 100 mA to 100 AAC/DC peak Voltage output 10 A: 100 mV/A (1 V @ 10 A) 100 A: 10 mV/A (1 V @ 100 A) < 1 ° < 1.5 ° Red LED indicator DC to 100 kHz (-3 dB with current derating) > 1 M/100 pF 600 Vrms 6.5 ft (2 m) coaxial cable with insulated BNC terminal (10 to 30) °C: 85 ± 5 % RH (without condensation) (40 to 50) °C: 45 ± 5 % RH (without condensation) 0.46 in (11.8 mm) (9.09 x 1.42 x 2.64) in (231 x 36 x 67) mm 11.6 oz (329 g) with battery Polycarbonate UL 94 (32 to 122) °F (0 to 50) °C (-22 to 176) °F (-30 to 80) °C EN 61010-2-32, 600 V CAT III Yes Yes SL261 W/ BNC CONNECTOR FEATURES SL SERIES AC/DC CURRENT PROBES · Low AC and DC measurements · Measures from 10 mA to 100 A · Dual range selection · Unique design for probing in crowded|wiring areas · Hall effect sensor technology · UL approved for the United States and Canada · Flame retardant UL94 V2 rated · Use with DMMs, voltmeters and other voltage measuring instruments CATALOG NO. 1201.51 DESCRIPTION AC/DC Current Probe Model SL261 (10 A, 100 mV/A & 100 A, 10 mV/A, BNC) 20 www.aemc.com Technical Assistance (800) 343-1391 © Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved. Vol. 23 Rev.00 02/2023 CURRENT MEASUREMENT PROBES SR SERIES CURRENT PROBES SR600 SERIES Current probes well-suited for power applications where high accuracy and low phase shift is important SPECIFICATIONS MODELS SR601 SR604 SR651 SR661 ELECTRICAL Nominal Range Measurement Range Transformation Ratio Output Signal Phase Shift Overload Frequency Range Load Impedance Working/Common Mode Voltage Output Surge Protection Output Termination MECHANICAL Jaw Opening Maximum Conductor Size Maximum Bus Bar Size Dimensions Weight Material ENVIRONMENTAL Operating Temperature Storage Temperature Operating Relative Humidity SAFETY Electrical UL Approval 1000 AAC 1000 AAC 10, 100, 1000 AAC 0.1 to 1200 AAC 1000: 1 Voltage output 1 mA/A (1 AAC @ 1000 A) 1mV/A 100 mV; 10 mV; 1 mV/A (1 VAC @ 1000 A) (1 VAC @ 10, 100; 1000 A) 10 A: 3 ° 50 A: 1.5 ° 200 A: 0.75 ° 1000 A: 0.5 ° 1200 A: 0.5 ° (10 A Range) 10 A: 15 ° (100 A Range) 20 A: 15 ° 100 A: 10 ° 120 A: 5 ° (1000 A Range) 200 A: 3 ° 1000 A: 2 ° 1200 A: 1 ° 1200 A for 40 min ON, 20 min OFF 30 Hz to 5 kHz* 10 Hz to 100 kHz* 5 max 100 k min 1 M min 600 V CAT III 30 V peak (2) 4 mm Lead safety banana with jacks plugs (2) 4 mm safety banana jacks N/A 6.5 ft (2 m) coaxial cable with BNC terminal 2.25 in (57 mm) max 2.05 in (52 mm) (1) (1.95 x 0.19) in (50 x 5) mm (4.37 x 8.50 x 1.77) in (111 x 216 x 45) mm 1.21 lb (550 g) Polycarbonate UL 94 (14 to 122) °F (-10 to 50) °C (-4 to 158)°F (-20 to 70) °C (0 to 85) % RH decreasing linearly above 95 °F (35 °C) EN 61010-2-32, 600 V CAT III Yes - United States and Canada Consult factory for NIST Calibration prices SR601 FEATURES · Measurement range of 100 mA to 1200 AAC · Large jaw opening accommodates up to two 500 kcmil conductors · Ergonomic design and easy operation · Low phase shift for power measurements · Available with mA or mV output signals · Designed for DMMs, recorders, loggers, oscilloscopes, power and harmonic meters · UL approved ACCESSORIES Catalog #1017.45 4 mm Banana plug adaptor (Safety Leads to non-recessed plug) Catalog #2118.46 Banana (Female) BNC (Male) Adaptor *Current derating above 1 kHz using the formula: 1000 A x 1/F (in kHz) CATALOG NO. 2113.43 2113.44 2113.45 2113.49 DESCRIPTION AC Current Probe Model SR601 (1000 A, 1 mA/A, Jack) L** AC Current Probe Model SR604 (1000 A, 1 mA/A, Lead) L** AC Current Probe Model SR651 (1000 A, 1 mV/A, Jack) AC Current Probe Model SR661 (10 A, 100 mV/A; 100 A, 10 mV/A & 1000 A, 1 mV/A, BNC) Vol. 23 Rev.00 02/2023 Technical Assistance (800) 343-1391 © Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved. **L - Limited open Voltage Output www.aemc.com 21 CURRENT MEASUREMENT PROBES SR SERIES CURRENT PROBES SR700 SERIES Excellent linearity and low phase shift, plus a broad frequency response, permit accurate measurements of current for power and power quality measurements SPECIFICATIONS MODELS ELECTRICAL Nominal Range Measurement Range Transformation Ratio Output Signal Phase Shift Overload Frequency Range Load Impedance Working/Common Mode Voltage Output Termination MECHANICAL Jaw Opening Maximum Conductor Size Maximum Bus Bar Size Dimensions Weight Material ENVIRONMENTAL Operating Temperature Storage Temperature Operating Relative Humidity SAFETY Electrical UL Approval SR701 SR704 SR752 SR759 1000 AAC 1 mA to 1200 AAC 100 mA to 1200 AAC 1, 10, 100, 1000 AAC 1 mA to 1200 AAC 1000: 1 Voltage output 1 mA/A 1 mV/A 1000, 100, 10, 1 mV/A, (1 AAC @ 1000 A) (1 VAC @ 1000 A) (1 VAC @ 1, 10, 100 or 1000 A) (1 A Range) (0.1 to 1.2) A: 10 ° (10 A Range) (1 to 10) A: 2 ° (0.1 to 1) A: 5 °; (1 to 12) A: 2 ° (10 to 100) A: 1 ° (100 A Range) (100 to 1200) A: 0.7 ° (1 to 10) A: 2 °; (10 to 120) A: 1 ° (1000 A Range) (10 to 100) A: 2 °; (100 to 1200) A: 1 ° 1200 A for 40 min ON, 20 min OFF 30 Hz to 5 kHz; current derating above 1 kHz using the formula: 1000 A x 1/F (in kHz) 5 max 100 k min 600 V CAT III (2) 4 mm safety banana jacks 5 ft (1.5 m) lead with 4 mm safety banana plugs 2.25 in (57 mm) max 2.05 in (52 mm) (1) (1.95 x 0.19) in (50 x 5) mm (4.37 x 8.50 x 1.77) in (111 x 216 x 45) mm 1.21 lb (550 g) Polycarbonate UL 94 (0 to 85) % (14 to 122) °F (-10 to 50) °C (-4 to 158) °F (-20 to 70) °C (0 to 90) % EN 61010-2-32 Yes - United States and Canada Consult factory for NIST Calibration prices SR701 FEATURES · Measurement range of 1 mA to 1200 AAC · Large jaw opening accommodates conductors up to two 500 MCM conductors · Ergonomic design and easy operation · Low phase shift for power measurements · Available with mA output signals · Designed for DMMs, recorders, loggers, oscilloscopes, power and harmonic meters · UL approved ACCESSORIES Catalog #1017.45 4 mm Banana plug adaptor (Safety Leads to non-recessed plug) Catalog #2118.46 Banana (Female) BNC (Male) Adaptor CATALOG NO. DESCRIPTION 2116.29 AC Current Probe Model SR701 (1000 A, 1 mA/A, Jack) HA* L** 2116.30 AC Current Probe Model SR704 (1000 A, 1 mA/A, Lead) HA* L** 2116.32 2116.33 AC Current Probe Model SR752 (1000 A, 1 mV/A, Lead) HA* AC Current Probe Model SR759 (1 A, 10 A, 100 A, 1000 A, mV/A, Lead) HA* *HA - High Accuracy and Low Phase Shift, **L - Limited open Voltage Output 22 www.aemc.com Technical Assistance (800) 343-1391 © Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved. Vol. 23 Rev.00 02/2023 CURRENT MEASUREMENT PROBES MN SERIES AC CURRENT PROBES MN SERIES Small and compact, ideal complement for any meter to measure AC currents in low-power secondary transformers or industrial applications SPECIFICATIONS Patent #1385787 - Mini-Clamp Design MODELS MN01 MN02 MN05 MN09 ELECTRICAL Nominal Range 150 AAC 100 AAC 10 AAC; 100 AAC 150 AAC Measurement Range (2 to 150) AAC 50 mA to 100 AAC (1 load) 50 mA to 90 AAC (10 load) 5 mA to 10 AAC (1 to 100) AAC (1 to 150) AAC Transformation Ratio 1000:1 Voltage output N/A Output Signal 1 mA/A (150 mAAC @ 150 A) 1 mA/A (100 mAAC @ 100 A) 1 mV/mA, 1 mV/A (10 VAC @ 10 A, 100 mVAC @ 100 A ) 100 mV/A (15 VDC @ 150 AAC) Phase Shift Not specified < 3 ° (1 load) < 6 ° (10 load) Not specified Overload 170 A for 10 min ON, 30 min OFF 10 A Range: 15 A 170 A for 10 min ON, 100 A Range: 150 A 30 min OFF Frequency Range (48 to 500) Hz 48 Hz to 10 kHz (48 to 500) Hz Load Impedance 10 1 M 50 K Open Secondary Voltage 30 V 30 V Output Termination 5 ft (1.5 m) lead with (2) 4 mm safety banana plugs MECHANICAL Maximum Conductor Size Ø 0.39 in (10 mm) Dimension (5.12 x 1.5 x 1) in (130 x 38 x 25) mm Weight 6.35 oz (180 g) Material Polycarbonate UL 94 V2 ENVIRONMENTAL Operating Temperature (14 to 122) °F (-10 to 50) °C Storage Temperature (-40 to 176) °F (-40 to 80) °C Operating Relative Humidity (0 to 85) % RH decreasing linearly above 95 °F (35 °C) SAFETY Safety Rating IEC 61010-2-32: 300 V CAT IV, 600 V CAT III, Pollution Degree 2 Ingress Protection IP40 Consult factory for NIST Calibration prices MN01 * IP 40 *MN09 only FEATURES · Clothes pin shape makes them ideal for use in tight areas, such as breaker panels, controller panels or outlets · Jaw opening accommodates conductors up to 0.39 in diameter MN01 · Measurements from 2 A to 150 AAC · Excellent companions to all DMMs, permits very low AC current measurements MN02 · Measurement ranges: 50 mA to 100 A (1 load) 50 mA to 90 A (10 load) · Designed for DMMs, loggers, recorders and oscilloscopes · (48 to 10,000) Hz frequency range · 1 mA/A from (1 to 10) load output signals MN05 · Measurements from 5 mA to 100 AAC · Permits very low AC current measurements MN09 · Measurements from (1 to 150) AAC · DC voltage output enables you to overcome low AC sensitivity of certain measurement instruments CATALOG NO. 2129.17 2129.20 2129.19 2129.21 DESCRIPTION AC Current Probe Model MN01 (150 A, 1 mA/A, Lead) AC Current Probe Model MN02 (100 A, 1 mA/A, Lead, 1 % Accuracy) AC Current Probe Model MN05 (100 A, 1 mV/A & 10 A, 1 V/A, Lead) AC Current Probe Model MN09 (150 A, 100 mVDC/AAC, Lead) Vol. 23 Rev.00 02/2023 Technical Assistance (800) 343-1391 © Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved. www.aemc.com 23 CURRENT MEASUREMENT PROBES MN SERIES AC CURRENT PROBES MN SERIES Compact sized probes ideal for measuring low currents and leakage currents Standard millivolt or milliamp outputs are compatible with multimeters, data loggers and oscilloscopes SPECIFICATIONS Patent #1385787 - Mini-Clamp Design MODELS MN103 MN114 MN185 ELECTRICAL Nominal Range 10 AAC, 100 AAC 10 AAC 120 AAC Measurement Range Transformation Ratio 1 mA to 10 AAC (1 to 100) AAC Voltage output 1 mA to 10 AAC Voltage output 50 mA to 120 AAC 1000:1 Output Signal 1 mV/mA, 1 mV/A (10 VAC @ 10 A, 100 mVAC @ 100 A) 100 mV/A (1 VAC @ 10 A) 1 mA/A (120 mAAC @ 120 A) Phase Shift (10 to 100) A, (45 to 65) Hz: 8 ° (1 to 100) A, (50 to 60) Hz: 3.5 ° Overload 20 A continuous 170 A continuous Frequency Range (45 to 500) Hz (30 to 5) kHz (30 to 10) kHz Load Impedance 100 k 100 k 5 non-inductive Working/Common Mode Voltage 250 VAC/250 VAC 250 VAC/30 VAC Output Termination 5 ft (1.5 m) lead with 4 mm safety banana plugs (2) 4 mm banana jacks MECHANICAL Jaw Opening 0.78 in (20 mm) Maximum Conductor Size 0.47 in Ø max (12 mm) Dimensions (1.26 x 4.53 x 0.87) in (32 x 115 x 22) mm Weight 5.6 oz (159 g) Material Polycarbonate UL 94 ENVIRONMENTAL Operating Temperature (14 to 122) °F (-10 to 50) °C (-13 to 122) °F (-25 to 50) 0 °C Storage Temperature (-40 to 176) °F (-40 to 80) °C SAFETY Safety Rating 3 kV (50/60) Hz dielectric for 1 min Probes MN 103/114 and 185 are not CE marked Consult factory for NIST Calibration prices MN103 MN185 FEATURES · Measurement range of 1 mA to 120 AAC · Jaw opening of 0.78 inch · Accommodates conductors up to 0.47 inch diameter · Ergonomic design and easy operation · Compact size accommodates hard to reach locations · Low phase shift for power measurements · Available with mV or mA output signals · Constructed with UL94VO flame retardant material · Designed for DMMs, recorders, loggers and oscilloscopes CATALOG NO. 1031.02 2110.71 100.185 DESCRIPTION AC Current Probe Model MN103 (10 A, 1 mV/mA & 100 A, 1 mV/A, Lead) AC Current Probe Model MN114 (10 A, 100 mV/A, Lead) AC Current Probe Model MN185 (100 A, 1 mA/A, Jack) 24 www.aemc.com Technical Assistance (800) 343-1391 © Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved. Vol. 23 Rev.00 02/2023 CURRENT MEASUREMENT PROBES LM SERIES MODELS LM102 & LM103 Equipped with high performance magnetic material offering excellent linearity and improved performance Ideal current measurement tool for use with multimeters, data loggers and power analyzers SPECIFICATIONS MODELS ELECTRICAL Nominal Range Measurement Range Transformation Ratio Output Signal Phase Shift Overload Frequency Range Load Impedance Open Secondary Voltage Output Termination MECHANICAL Maximum Conductor Size Dimensions Weight Material ENVIRONMENTAL Operating Temperature Storage Temperature Operating Relative Humidity SAFETY Safety Rating Ingress Protection Consult factory for NIST Calibration prices Patent #1385787 - Mini-Clamp Design LM102 LM103 200 AAC 50 mA to 200 AAC (1 or 10 load) 100 mA to 200 A 1000:1 Voltage Output 1 mA/A (200 mAAC @ 200 A) 1 mV/A (200 mVAC @ 200 A) 3 ° (1 load) 6 ° (10 load) 3 ° 350 A continuous @ 1 kHz 200 A continuous @ 8 kHz 48 Hz to 10 kHz 10 10 k 30 V Double-insulated 5 ft (1.5 m) lead with (2) 4 mm safety banana plugs Ø 0.63 in (16 mm) (5.13 x 1.81 x 1.34) in (130 x 46 x 34) mm Approximately 8.8 oz (250 g) Polycarbonate UL 94 (14 to 122) °F (-10 to 50) °C (-40 to 176) °F (-40 to 80) °C (0 to 85) % RH decreasing linearly above 95 °F (35 °C) EN 61010-1, EN 61010-2-031, EN 61010-2-032 600 V CAT III, 300 V CAT IV Pollution Degree 2 IP20 (EN 60529) LM102 IP 20 FEATURES · Clamping diameter 0.63 inch (16 mm) · Measurement range from 0.05 Amps to 200 Amps · Over range up to 350 Amps continuous · 1 mA/A output (Model LM102) · 1 mV/A output (Model LM103) · Clothes pin design allows access to tight places · Frequency response from 48 Hz to 10 kHz · Arrow marker clearly assists in proper orientation for power measurement applications CATALOG NO. 2153.04 2153.05 DESCRIPTION AC Current Probe Model LM102 (200 A/1 mA/A) AC Current Probe Model LM103 (200 A/1 mV/A) Vol. 23 Rev.00 02/2023 Technical Assistance (800) 343-1391 © Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved. www.aemc.com 25 CURRENT MEASUREMENT PROBES MN SERIES AC CURRENT PROBES MN200 SERIES General purpose AC current probe with voltage output, for use with DMMs or with measuring instruments with voltage input Permits measurement or recording of current with instruments that do not have current ranges. Output signal proportional to current measured SPECIFICATIONS MODELS ELECTRICAL Nominal Range Measurement Range Transformation Ratio Output Signal Phase Shift (20 A Range) MN255 20 AAC; 200 AAC (0.1 to 24) AAC; (0.1 to 240) AAC Voltage output 20 A: 100 mV/A (20 VAC @ 200 A) 200 A: 10 mV/A (2 VAC @ 200 A) Not Specified MN261 MN291 (0.1 to 24) A; (0.1 to 240) A 100 mV/A (2 V @ 20 A), 10 mV/A AC (2 V @ 200 A) 200 AAC (0.5 to 240) AAC DC Voltage output 100 mVDC/AAC (20 VDC @ 200 A) Not Specified (200 A Range) 0.5 A to 10 A Not Specified Not Specified 10 A to 40 A 5 ° 6 ° 40 A to 100 A 100 A to 240 A 3 ° 2.5 ° 4 ° 3 ° Overload (24 and 240) A for 10 min ON, 30 min OFF Frequency Range 40 Hz to 10 kHz (-3dB) Load Impedance Working/Common Mode Voltage Output Termination MECHANICAL Jaw Opening Maximum Conductor Size Maximum Bus Bar size Dimensions Weight Material ENVIRONMENTAL Operating Temperature Storage Temperature Operating Relative Humidity SAFETY Safety Rating UL Approval Ingress Protection > 1 M 600 V Double-insulated 5 ft (1.5 m) lead with (2) 4 mm safety banana plugs 0.83 in (21 mm) Ø 0.78 in max (20 mm) (0.78 x 0.19) in (20 x 5) mm (5.47 x 2.00 x 1.18) in (139 x 51 x 30) mm 6.5 oz (184 g) Polycarbonate UL 94 (14 to 131) °F (-10 to 55 ) °C (-40 to 158) °F (-40 to 70) °C (10 to 90) % RH EN/IEC 61010-2-32 600 V CAT III, EN/IEC 61010-032 Yes - United States and Canada IP40 Consult factory for NIST Calibration prices MN255 IP 40 FEATURES · Small compact size · Measurement ranges from 100 mA to 240 A · Frequency response to 10 kHz · UL approved for both United States and Canada · Designed to EN61010, 600 V CAT III · Jaw opening accommodates 250 kcmil cables · Constructed with UL94VO flame retardant material · Double insulated construction CATALOG NO. DESCRIPTION 2115.81 AC Current Probe Model MN255 (20 A, 100 mV/A & 200 A, 10 mV/A, Lead) 2115.82 AC Current Probe Model MN261 (20 A, 100 mV/A & 200 A, 10 mV/A, BNC) 2115.84 AC Current Probe Model MN291 (200 A, 100 mVDC/A, Lead) 26 www.aemc.com Technical Assistance (800) 343-1391 © Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved. Vol. 23 Rev.00 02/2023 CURRENT MEASUREMENT PROBES MN SERIES AC CURRENT PROBES MN300 SERIES Compact sized probes ideal for measuring low currents and leakage currents MN307 Standard millivolt and milliamp outputs are compatible with multimeters, data loggers and oscilloscopes SPECIFICATIONS MODELS ELECTRICAL Nominal Range Measurement Range Transformation Ratio MN307 10 AAC (0.1 to 12) AAC Voltage output Output Signal 100 mV/A (1 VAC @ 10 A) Phase Shift (0.1 to 1) A: 5 ° (1 to 5) A: 3 ° (5 to 12) A: 2.5 ° Overload 20 A Continuous Frequency Range Load Impedance 1 M Crest Factor 3 @ 10 Arms with an error (due to CF) of 3 % Working/Common Mode Voltage Output Termination Double-insulated 5 ft (1.5 m) lead with (2) 4 mm safety banana plugs MECHANICAL / ENVIRONMENTAL Jaw Opening Maximum Conductor Size Dimensions Weight Material Operating Temperature Storage Temperature Operating Relative Humidity SAFETY Safety Rating UL Approval Consult factory for NIST Calibration prices IP 40 MN312 MN352 MN353 MN375 MN379* 1000:1 1 mA/A (150 mAAC @ 150 A) 150 AAC (0.1 to 200) AAC 10 mV/A (1.5 VAC @ 150 A) 10 AAC (0.1 to 10) AAC Voltage output 100 mV/A (1 VAC @ 10 A) (0.1 to 1) A: Not specified (1 to 20) A: 3 ° (20 to 80) A: 2 ° (80 to 150) A: 2.5 ° (150 to 200) A: Not specified (1 to 5) A: 1 ° @ 60 Hz (5 to 10) A: 1.5 ° @ 60 Hz 200 A Continuous 240 A for 10 min ON, 30 min OFF 40 Hz to 10 kHz 1 3 @ 200 A peak with an error (due to CF) of 3 % 3 @ 150 A peak with an error (due to CF) of 3 % 600 Vrms 20 A Continuous 40 Hz to 3 kHz 1 M 3 @ 10 Arms with an error (due to CF) of 3 % 5 AAC; 100 AAC 5 mA to 6 AAC; (0.1 to 120) AAC 5 A: 200 mV/A (1 VAC @ 5 A) 100 A: 10 mV/A (1 VAC @ 100 A) (5 A Range) 5 mA: 6.5 ° 50 mA: 5 ° 0.5 A: 4.5 ° 5 A: 4 ° (100 A Range) 0.1 A: 3.2 ° (1; 10; 100) A: 2.2 ° 200 A Continuous 40 Hz to 10 kHz Not specified (2) standard safety 4 mm banana jacks Double-insulated 5 ft (1.5 m) lead with (2) 4 mm safety banana plugs 0.83 in (21 mm) 0.78 in max (20 mm) (5.47 x 2.00 x 1.18) in (139 x 51 x 30) mm 6.5 oz (180 g) Polycarbonate UL 94 (14 to 131) °F (-10 to 55) °C (-40 to 158) °F (-40 to 70) °C 85 % RH without roll-off above 95 °F (95 °C) EN/IEC 61010-1 600 V CAT III, EN 61010-2-32, Pollution Degree 2 Yes - United States and Canada *(excludes MN379) CATALOG NO. DESCRIPTION 2116.23 AC Current Probe Model MN307 (12 A, 100 mV/A, Lead) 2116.24 AC Current Probe Model MN312 (150 A, 1 mA/A, Jack) 2116.26 AC Current Probe Model MN352 (150 A, 10 mV/A, Jack) CATALOG NO. DESCRIPTION 2116.27 AC Current Probe Model MN353 (150 A, 10 mV/A, Lead) 2115.41 AC Current Probe Model MN375 (10 A, 100 mV/A, Lead) 2153.01 AC Current Probe Model MN379 (5 A, 200 mV/A & 100 A, 10 mV/A, Lead) Vol. 23 Rev.00 02/2023 Technical Assistance (800) 343-1391 © Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved. www.aemc.com 27 CURRENT MEASUREMENT PROBES MR SERIES AC/DC CURRENT PROBES MODELS MR415 / 416 / 526 General Purpose Hall Effect Current Probes for use with DMMs, Data Loggers and Power Analyzers SPECIFICATIONS MODELS MR415 MR416 MR526 ELECTRICAL Current Range Output Signal (0.5 to 400) AAC, 600 ADC 1 mV/A (0.5 to 40) AAC, 60 ADC (0.5 to 400) AAC, 600 ADC 10 mV/A, 1 mV/A (0.5 to 100) AAC, 150 ADC (0.5 to 1000) AAC, 1400 ADC 10 mV/A, 1 mV/A Frequency Range Phase Shift At (50/60) Hz Load Impedance DC to 30 kHz (-3 dB) (depending of current value) 1.5 ° @ 400 A 2.2 ° @ 40 A 1.5 ° @ 400 A 2 ° @ 100 A 1.5 ° @ 800 A > 1 M and 100 pF Overload 3000 ADC or 1000 AAC continuous for < 1 kHz Zero Adjust Automatic on both ranges Power Supply 9 V Alkaline battery (NEDA 1060A, 6LR61) or 5 V DC Micro-USB Type B Battery Life 50 h typical Low Battery Indication Green LED blinking Overload Indication Red LED on when measurement > selected range Output Termination Double-insulated 5 ft (1.5 m) lead with (2) 4 mm safety banana plugs MECHANICAL Maximum Conductor Size Dimensions (H x W x D) Weight (with Battery) Cables: (1) 1.18 in (30 mm) or (2) .94 in (24 mm) Bus Bar: (1) (1.97 x 0.39) in (50 x 10) mm or (2) (1.23 x 0.39) in (31 x 10) mm or (3) (0.98 x 0.31) in (25 x 8) mm (8.82 x 3.82 x 1.73) in (224 x 97 x 44) mm 0.98 lb (444 g) Cables: (1) 1.5 in (38 mm) or (2) 1 in (25 mm) Bus Bar: (1) (1.97 x 0.49) in (50 x 12) mm or (2) (0.98 x 0.2) in (25 x 5) mm; (1) (1.24 x 0.30) in (31 x 8) mm or (3) (0.98 x 0.31) in (25 x 8) mm (9.31 x 3.82 x 1.73) in (236 x 97 x 44) mm 1.15 lb (521 g) ENVIRONMENTAL Operating Temperature (14 to +131) °F (-10 to 55) °C Storage Temperature (-40 to +176) °F (-40 to 80) °C Relative Humidity Up to 85 % RH @ 35 °C SAFETY Ingress Protection IP40 EMC EN 61326-1 Safety Rating IEC 61010-1, EN 61010-2-32, Pollution Degree 2, 600 V CAT III Consult factory for NIST Calibration prices MR415 MR416 MR526 IP 40 FEATURES · The jaw shape enables users to clamp on to cables or small bus bars · Powered by battery or standard external 5 V power source via micro-USB connector · Measures up to 1000 AAC and 1400 ADC (model dependent) · Automatic Zero DC reset function · Auto Power Off enable/disable function · Millivolt output compatible with most equipment and instruments · Battery life up to 50 hours · Safety rating 600 V CAT III 4 mm Banana Plug Terminals CATALOG NO. 1200.80 1200.82 1200.83 DESCRIPTION AC/DC Current Probe Model MR415 (400 AAC, 1 mV/A & 600 ADC, 1 mV/A, 4 mm Banana Plug Lead) - Replaces MR410 AC/DC Current Probe Model MR416 (40 AAC, 60 ADC, 10 mV/A & 400 AAC, 600 ADC, 1 mV/A, 4 mm Banana Plug Lead) - Replaces MR411 AC/DC Current Probe Model MR526 (100 AAC, 150 ADC, 10 mV/A & 1000 AAC, 1400 ADC, 1 mV/A, 4 mm Banana Plug Lead) - Replaces MR521 28 www.aemc.com Technical Assistance (800) 343-1391 © Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved. Vol. 23 Rev.00 02/2023 CURRENT MEASUREMENT PROBES MR SERIES AC/DC CURRENT PROBES MODELS MR417 / MR527 Hall Effect AC/DC current probes for Oscilloscopes and other instruments with waveform displays SPECIFICATIONS MODELS MR417 MR527 ELECTRICAL Current Range Output Signal (0.5 to 40) AAC, 60 ADC (0.5 to 400) AAC, 600 ADC (0.5 to 100) AAC, 150 ADC (0.5 to 1000) AAC, 1400 ADC 10 mV/A, 1 mV/A Frequency Range Phase Shift At (50/60) Hz DC to 30 kHz (-3 dB) (depending of current value) 2 ° @ 40 A 1.5 ° @ 400 A 2.2 ° @ 100 A 1.5 ° @ 1000 A Load Impedance > 1 M and 100 pF Overload 3000 ADC or 1000 AAC continuous for < 1 kHz Zero Adjust Automatic on both ranges Power Supply 9 V alkaline battery (NEDA 1060 A, 6LR61) or 5 V DC Micro-USB Type B Battery Life 50 hours typical Low Battery Indication Green LED blinking Overload Indication Red LED on when measurement > selected range Output Termination 6.5 ft (2 m) coaxial cable with insulated BNC terminal MECHANICAL Maximum Conductor Size Dimensions (H x W x D) Cables: (1) 0.18 in (5 mm) or (2) .94 in (24 mm) Bus Bar: (1) (1.97 x 0.39) in (50 x 10) mm or (2) (1.23 x 0.39) in (31 x 10) mm or (3) (0.98 x 0.31) in (25 x 8) mm (8.82 x 3.82 x 1.73) in (224 x 97 x 44) mm Cables: (1) 1.5 in (38 mm) or (2) 1 in (25 mm) Bus Bar: (1) (1.97 x 0.49) in (50 x 12) mm or (2) (0.98 x 0.2) in (25 x 5) mm; (1) (1.24 x 0.30) in (31 x 8) mm or (3) (0.98 x 0.31) in (25 x 8) mm (9.31 x 3.82 x 1.73) in (236 x 97 x 44) mm Weight (with Battery) 0.98 lb (440 g) 1.15 lb (521 g) ENVIRONMENTAL Operating Temperature (14 to +131) °F (-10 to 55) °C Storage Temperature (-40 to +176) °F (-40 to 80) °C Relative Humidity Up to 85 % RH @ 35 °C SAFETY Ingress Protection IP 40 EMC EN 61326-1 Safety Rating IEC 61010-1, EN 61010-2-32, Pollution Degree 2, 600 V CAT III MR417 MR527 IP 40 FEATURES · The jaw shape enables users to clamp on to cables or small bus bars · Powered by battery or standard external 5 V power source via micro-USB connector · Measures up to 1000 AAC and 1400 ADC (model dependent) · Equipped with a Zero DC reset function · Auto Power Off enable/disable function · LED overload and low battery indicators · Millivolt output compatible with most equipment and instruments · Equipped with a coaxial lead and isolated BNC connectors for direct connection to an oscilloscope · Battery life up to 50 hours · Safety rating 600 V CAT III BNC Connector CATALOG NO. 1200.84 1200.85 DESCRIPTION AC/DC Current Probe Model MR417 (40 AAC, 60 ADC, 10 mV/A & 400 AAC, 600 ADC, 1 mV/A, BNC Output) Replaces MR461 AC/DC Current Probe Model MR527 (100 AAC, 150 ADC, 10 mV/A & 1000 AAC, 1400 ADC, 1 mV/A, BNC Output) Replaces MR561 Vol. 23 Rev.00 02/2023 Technical Assistance (800) 343-1391 © Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved. www.aemc.com 29 CURRENT MEASUREMENT PROBES MH SERIES MODEL MH60 Designed to measure AC and DC currents using dual Hall effect and transformer technology at frequencies to 1 MHz Self-powered directly from oscilloscope or line-power via line-adapter SPECIFICATIONS MODEL ELECTRICAL Nominal Range Measurement Range Transformation Ratio Output Signal Phase Shift Overload Frequency Range (@ -3 dB) Load Impedance Common Mode Voltage Power Supply Battery Life Output Termination MECHANICAL Maximum Conductor Size Dimensions Weight Material ENVIRONMENTAL Operating Temperature Storage Temperature Operating Relative Humidity SAFETY CE Mark Double Insulation Ingress Protection Safety Rating MH60 100 AAC/DC (140 A peak) 500 mA to 100 AAC / 100 ADC Voltage Output 10 mV/A (1 VAC/DC @ 100 A) 1 ° 150 A Continuous DC to 1 MHz 0.25 m (at 400 Hz) 0.628 m (at 1 MHz) In RF: 0.1 µH for a primary transition (600 V Max) At 50 Hz: 3.5 mA / 5 mA @ 100 V At 400 Hz: 25.9 mA / 50 mA @ 100 V Internal NiMH rechargeable battery; 5 VDC external via female micro-USB Type B connection 8 h typical with fully-charged battery 6.6 ft (2 m) lead with molded isolated male BNC connector Ø 1.02 in (26 mm) (5.43 x 1.92 x 1.10) in (138 x 49 x 28) mm Approximately 7.05 oz (200 g) Polycarbonate UL 94 (14 to 122) °F (-10 to 50) °C (-4 to 122) °F (-20 to 50) °C Up to 85 % RH decreasing linearly above 95 °F (35 °C) Yes Yes IP40 (EN 60529) EN 61010-1 EN 61010-2-31 600 V CAT II, 300 V CAT III Pollution Degree 2 FEATURES · Clamping diameter 1.02 in (26 mm) · Measurement range from (0.5 to 100) Amps AC, 100 Amps DC · Measures AC and DC signals · 10 mV/A output · Automatic compensation for earth's magnetic influence · Battery Power (8 hour battery life) or USB continuous · Frequency response from DC to 1 MHz · Selectable 3 kHz or 30 kHz filter selection · Push button zero adjust · LED indicators for power, overload and filter selection · UL 94 V2 self-extinguishing case material CATALOG NO. 2153.03 DESCRIPTION AC/DC Current Probe Model MH60 (100 A, 1 MHz, BNC) 30 www.aemc.com Technical Assistance (800) 343-1391 © Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved. Vol. 23 Rev.00 02/2023 CURRENT MEASUREMENT PROBES DIGITAL FLEXPROBE® MODELS 400D & 4000D Provide a welcomed solution when accessing electrical conductors in tight places MINIFLEX: 400D-10 (10 in probe) MINIFLEX: 4000D-14 (14 in probe) SPECIFICATIONS MODELS 400D-10 & 400D-24 4000D-14 & 4000D-24 ELECTRICAL Display Range 4 AAC, 40 AAC, 400 AAC 40 AAC, 400 AAC, 4000 AAC Measurement Range (0.020 to 3.999) A, (4.00 to 39.99) A (40.0 to 399.9) A (0.20 to 39.99) A, (40.0 to 399.9) A, (400 to 3999) A Resolution 1 mA, 10 mA, 100 mA 10 mA, 100 mA, 1 A Sensor Diameter 400D-10: Ø 2.75 in (70 mm) 4000D-14: Ø 3.94 in (100 mm) 400D-24: Ø 8 in (203 mm) 4000D-24: Ø 8 in (203 mm) Sensor Length 400D-10: Ø 10 in (254 mm) 4000D-14: Ø 14 in (355 mm) 400D-24: Ø 24 in (610 mm) 4000D-24: Ø 24 in (610 mm) Bandwidth 10 Hz to 3 kHz MECHANICAL Power Supply (2) 1.5 V AAA / LR3 batteries Weight Approx. 0.29 lb (132 g) MiniFlex Casing Dimensions (3.94 x 2.36 x 0.79) in (100 x 60 x 20) mm Connection Cable Length 6 ft (1.8 m) ENVIRONMENTAL Operating Temperature (32 to 122) °F (0 to 50) °C SAFETY Safety Rating IEC 61010, 600 V CAT IV Consult factory for NIST Calibration prices PRODUCT INCLUDES Digital FlexProbe®, (2) 1.5 V AAA batteries and user manual. MINIFLEX: 400D-24 (24 in probe) 4000D-24 (24 in probe) (shown) FEATURES · Easy access and measurement, even in confined spaces · Measurement from 20 mAAC to 4000 AAC (model dependent) · Available with (10, 14 and 24) inch sensor lengths · Sensor diameter 2.75 in (70 mm) to 8 in (203 mm) (model dependent) · Resolution down to 1 mA (model dependent) · HOLD feature · Direct reading · Compact and simple to use · Flexible current sensor · True RMS · Safety rating of 600 V CAT IV ACCESSORIES CATALOG #5000.44 MultiFix (universal mounting system) for use with models 5231, 5233, 400D, and 4000D CATALOG NO. 2153.31 2153.36 2153.32 2153.35 DESCRIPTION Digital FlexProbe® Model 400D-10 w/6' Lead (TRMS, 4 AAC, 40 AAC, 400 AAC) Digital FlexProbe® Model 400D-24 w/6' Lead (TRMS, 4 AAC, 40 AAC, 400 AAC) Digital FlexProbe® Model 4000D-14 w/6' Lead (TRMS, 40 AAC, 400 AAC, 4000 AAC) Digital FlexProbe® Model 4000D-24 w/6' Lead (TRMS, 40 AAC, 400 AAC, 4000 AAC) Vol. 23 Rev.00 02/2023 Technical Assistance (800) 343-1391 © Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved. www.aemc.com 31 CURRENT MEASUREMENT PROBES GENERAL PURPOSE PROBES SELECTION CHART Series Model MN01 MN02 MN05 MN09 MN103 MN114 Ratio Measurement Range AC DC Output Signal Current Voltage 1000:1 (2 to 150) A 1000:1 50 mA to 100 A 50 mA to 90 A 5 mA to 10 A (1 to 100) A 1 mA/A* 1 mV/mA 1 mV/A (1 to 150) A 100 mVDC/AAC 1 mA to 10 A (1 to 100) A 1 mV/mA 1 mV/A 1 mA to 10 A 100 mV/A Phase Shift** N/A N/A N/A N/A N/A < 8 ° Maximum Conductor Size Ø Cable Bus Bar 0.39 in (10 mm) N/A 0.39 in (10 mm) N/A 0.39 in (10 mm) N/A 0.39 in (10 mm) N/A 0.47 in (12 mm) N/A 0.47 in (12 mm) N/A Output Connec- tion Catalog No. Leads 2129.17 Leads 2129.20 Leads 2129.19 Leads 2129.21 Leads 1031.02 Leads 2110.71 MN185 1000:1 50 mA to 120 A 1 mA/A < 3.5 ° 0.47 in (12 mm) N/A Jacks 100.185 MN255 (0.1 to 24) A (0.1 to 240) A 100 mV/A 10 mV/A < 2.5 ° 0.78 in (20 mm) N/A Leads 2115.81 MN261 (0.1 to 24) A (0.5 to 240) A 100 mV/A 10 mV/A < 6 ° 0.78 in (20 mm) N/A BNC 2115.82 MN291 (0.5 to 240) A 100 mVDC/AAC N/A 0.78 in (20 mm) N/A Leads 2115.84 MN307 10 mA to 12 A 100 mV/A < 2.5 ° 0.78 in (20 mm) N/A Leads 2116.23 MN312 1000:1 (0.1 to 200) A 1 mA/A* < 2.5 ° 0.78 in (20 mm) N/A Jacks 2116.24 MN352 (0.1 to 150) A MN353 < 2.5 ° 0.78 in (20 mm) N/A Jacks 2116.26 10 mV/A < 2.5 ° 0.78 in (20 mm) N/A Leads 2116.27 MN373 (0.1 to 24) A (0.1 to 200) A 1000 mV/A 10 mV/A < 3 ° 0.78 in (20 mm) N/A Leads 2116.28 MN375 (0.1 to 10) A 100 mV/A < 1.5 ° 0.78 in (20 mm) N/A Leads 2115.41 MN379 5 mA to 6 A (0.1 to 120) A 200 mV/A 10 mV/A < 4 ° 0.78 in (20 mm) N/A Leads 2153.01 MN379T 5 mA to 6 A (0.1 to 120) A 200 mV/A 10 mV/A < 4 ° 0.78 in (20 mm) N/A Lead w/ 2153.02 BNC SL206 10 mA to 1.5 A 10 mA to 2 A 50 mA to 60 A 50 mA to 80 A 1 mV/mAAC/DC 10 mV/AAC/DC < 1 ° 0.46 in (12 mm) N/A Leads 1201.45 1.18 in MD301 1000:1 (2 to 500) A 1 mVDC/AAC N/A (30 mm) (2 x 500) (2.48 x 0.20) in (63 x 5) mm Leads 1201.07 kcmil *Output Protection for open secondary **Phase shift indicated at maximum rating Note: Models MN103, MN106, MN114 & MN185 are not CE compliant. MN200 & MN300 series are UL approved except MN379. Consult factory for NIST Calibration price. 32 www.aemc.com Technical Assistance (800) 343-1391 © Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved. Vol. 23 Rev.00 02/2023 CURRENT MEASUREMENT PROBES GENERAL PURPOSE PROBES SELECTION CHART SERIES MODEL RATIO MEASUREMENT RANGE AC DC OUTPUT SIGNAL CURRENT VOLTAGE PHASE SHIFT** MR415 (0.5 to 400) A (0.5 to 600) A 1 mV/A 1.5 ° MR416 (0.5 to 40) A (0.5 to 60) A (0.5 to 400) A (0.5 to 600) A 10 mV/A 2.2 ° 1 mV/A 1.5 ° MR526 (0.5 to 100) A (0.5 to 150) A (0.5 to 1000) A (0.5 to 1400) A 10 mV/A 2 ° 1 mV/A 1.5 ° SR601 1000:1 (0.1 to 1200) A 1 mA/A* < 0.5 ° SR604 1000:1 (0.1 to 1200) A 1 mA/A* < 0.5 ° SR651 (0.1 to 1200) A 1 mV/A < 0.5 ° SR701 1000:1 1 mA to 1000 A 1 mA/A* < 0.7 ° SR704 1000:1 1 mA to 1000 A 1 mA/A* < 0.7 ° SR752 (0.1 to 1000) A 1 mV/A < 0.7 ° 1 mA to 1 A SR759 10 mA to 10 A (0.1 to 100) A (1 to 1000) A 1000 mV/A 100 mV/A 10 mV/A < 1 ° 1 mV/A MAXIMUM CONDUCTOR SIZE Ø CABLE BUS BAR OUTPUT CONNEC- TION CATALOG NO. 1.18 in (30 mm) 2 bus bar 5 ft (1.24 x 0.39) in (1.5 m) 1200.80 (31 x 10) mm Lead 1.53 in (39 mm) 2 bus bar 5 ft (1.95 x 0.19) in (1.5 m) 1200.82 (50 x 5) mm Lead 1.53 in (39 mm) 2 bus bar 5 ft (1.95 x 0.19) in (1.5 m) 1200.83 (50 x 5) mm Lead 2.05 in (52 mm) 2.05 in (52 mm) 2.05 in (52 mm) 2.05 in (52 mm) 2.05 in (52 mm) 2.05 in (52 mm) (1.95 x 0.19) in (50 x 5) mm (1.95 x 0.19) in (50 x 5) mm (1.95 x 0.19) in (50 x 5) mm (1.95 x 0.19) in (50 x 5) mm (1.95 x 0.19) in (50 x 5) mm (1.95 x 0.19) in (50 x 5) mm Jacks Leads Jacks Jacks Leads Leads 2113.43 2113.44 2113.45 2116.29 2116.30 2116.32 2.05 in (52 mm) (1.95 x 0.19) in (50 x 5) mm Leads 2116.33 K100 0.1 mA to 3 A 0.05 mA to ± 4.5 A 1 mV/mA N/A 0.18 in (4.5 mm) K110 (0.1 to 300) mA (0.05 to ± 450) mA 10 mV/mA N/A N/A Plugs 1200.67 N/A Plugs 2111.73 LM102 1000:1 50 mA to 200 A 1 mA/A* < 3 ° N/A 0.63 in LM103 (0.1 to 200) A (16 mm) 1 mV/A < 3 ° N/A *Output Protection for open secondary **Phase shift indicated at maximum rating Note: All SR probes listed on this chart are UL approved, however not all SR series probes are UL approved; please consult factory. Consult factory for NIST Calibration price. Leads 2153.04 Leads 2153.05 OUTPUT TERMINATIONS Lead with BNC Insulated 6.5 ft (2 m) coaxial cable with insulated BNC connector rated 600 Vrms Jacks Two standard safety banana jacks (4 mm) Leads Double/reinforced 5 ft (1.5 m) leads with 4 mm safety banana plug Shrouded Banana Plugs Two 4 mm safety banana plugs; standard ¾ in (19 mm) spacing Vol. 23 Rev.00 02/2023 Technical Assistance (800) 343-1391 © Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved. www.aemc.com 33 AMPFLEX® AND MINIFLEX® PROBES - SELECTION CHARTS SERIES MODEL RATIO MEASUREMENT RANGE OUTPUT SIGNAL MF 300-10-2-10-HF MF 3000-14-1-1-HF MA114 300-24-2-10 1000-24-1-1 1000-24-2-1 1000-36-2-1 3000-24-1-1 3000-36-1-1 3000-24-2-1 3000-48-2-1 6000-36-2-0.1 30000-24-2-0.1 30 A / 300 A 3000 A 3 A / 30 A / 300 A / 3000 A 30 A / 300 A 1000 A 100 A / 1000 A 100 A / 1000 A 3000 A 3000 A 300 A / 3000 A 300 A / 3000 A 600 A / 6000 A 3000 A / 30,000 A 100 mV/A, 10 mV/A 1 mV/A 1 mV/mA, 100 mV/A 10 mV/A, 1 mV/A 100 mV/A, 10 mV/A 1 mV/A 10 mV/A, 1 mV/A 10 mV/A, 1 mV/A 1 mV/A 1 mV/A 10 mV/A, 1 mV/A 1 mV/A 1 mV/A, 0.1 mV/A 1 mV/A, 0.1 mV/A MAXIMUM CONDUCTOR SIZE CATALOG NO. 2.95 in (75 mm) 2126.84 3.93 in (100 mm) 2126.86 4 in (101 mm) 2153.41 7.48 in ( 190 mm) 7.48 in ( 190 mm) 7.48 in ( 190 mm) 11 in (280 mm) 7.48 in (190 mm) 11 in (280 mm) 7.48 in (190 mm) 15 in (381 mm) 11 in (280 mm) 7.48 in (190 mm) 2112.88 2112.39 2112.98 2113.00 2112.46 2112.48 2113.05 2112.01 2113.21 2113.33 24-3001 300 A / 3000 AAC 10 mV/A, 1 mV/A 7.48 in (190 mm) 2120.81 Consult factory for NIST Calibration price OSCILLOSCOPE & BNC TERMINATED PROBES MODEL MEASUREMENT RANGE AC DC SL261 Note: Consult factory for NIST1C0(a01libmtoraA1ti0oton0)1pA0ricAe OUTPUT SIGNAL VOLTAGE 100 mV/A 10 mV/A PHASE SHIFT* < 1.5 ° MN261 (0.1 to 24) A (0.5 to 240) A 100 mV/A 10 mV/A < 2.5 ° SR661 MN251T MN379T MH60 (0.1 to 12) A (0.1 to 120) A (1 to 1200) A (0.5 to 240) A (0.005 to 6) A (0.1 to 120) A (0.5 to 100) A (0.5 to 100) A 100 mV/A 10 mV/A 1 mV/A 1 mV/A 200 mV/A 10 mV/A 10 mV/A < 1 ° < 2.5 ° < 4 ° < 2.2 ° < 1 ° MR417 MR527 (0.5 to 40) A (0.5 to 60) A (0.5 to 400) A (0.5 to 600) A (0.5 to 100) A (0.5 to 150) A (0.5 to 1000) A (0.5 to 1400) A 10 mV/A 1 mV/A 10 mV/A 1 mV/A 2.2 ° 1.5 ° 2.2 ° 1.5 ° MAXIMUM CONDUCTOR SIZE Ø CABLE BUS BAR 0.46 in (12 mm) N/A OUTPUT CONNECTION 6.5 ft (2 m) Lead w/BNC 0.78 in (20 mm) 6.5 ft (2 m) N/A Lead w/BNC 2.05 in (52 mm) (1.96 x 0.19) in (50 x 5) mm 6.5 ft (2 m) Lead w/BNC 0.78 in (20 mm) 1.02 in (26 mm) 1.18 in (30 mm) 1.53 in (39 mm) 0.78 in (20 mm) 10 ft (3 m) Lead w/BNC 6.6 ft (2 m) N/A Lead w/BNC 2 bus bar 6.6 ft (2 m) (1.24 x 0.39) in Lead (32 x 10) mm w/BNC 2 bus bar 6.6 ft (2 m) (1.96 x 0.19) in Lead (50 x 5) mm w/BNC *Phase shift indicated at maximum rating. Note: All probes are rated 600 V CAT III and CE compliant. Not all models are UL approved; please consult factory. Consult factory for NIST Calibration price. 34 www.aemc.com Technical Assistance (800) 343-1391 © Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved. Vol. 23 Rev.00 02/2023 DATA LOGGERS DATA ANALYSIS AND REPORTING SOFTWARE SEE PAGE 133 FOR MORE INFO ON DATAVIEW® SOFTWARE CONFIGURE DATA LOGGERS MODELS L261, L452, L562, DL913-914 Print reports of all test results / Configure all data logger functions and parameters from a PC including sample rate, recording length, channel configuration and more / Create and store a library of configurations / Capture, display and analyze data in real-time on a PC SEE WEBSITE FOR PRICING AND AVAILABILITY: WWW.AEMC.COM DATA LOGGERS SIMPLE LOGGER® II 600 VAC/AC+DC MODEL L261 One channel simple -logger for voltage measuring, monitoring and troubleshooting SPECIFICATIONS MODEL L261 ELECTRICAL Channels One Input Connection Two recessed 4 mm safety banana jacks Measurement Range (0 to 600) VAC/AC+DC Resolution 0.1 V Accuracy (50/60) Hz (0 to 5) V: unspecified (5 to 50) V: ± (0.5 % of Reading + 1 V) (50 to 600) V: ± (0.5 % of Reading + 0.5 V) Input Impedance 40 M Sample Rate 64 samples/cycle Storage Rate Programmable from 8 every s to 1 every d Storage Modes Recording Length Start/Stop, FIFO, Extended Recording Mode (XRMTM) and Alarm 15 min to 8 weeks, programmable using DataView® Memory 240,000 measurements (512 kB) The recorded data is stored in non-volatile memory and will be retained even if the battery is low or removed. Communication USB 2.0 optically isolated Power Supply (2) 1.5 V AA-cell alkaline batteries (included) Battery Life 100 h to > 45 d (dependent on sample rate and recording length) MECHANICAL Dimensions (4.94 x 2.75 x 1.28) in (125 x 70 x 32) mm Weight (with battery) 6.4 oz (181 g) Case UL94-V0 Vibration IEC 68-2-6 (1.5 mm, 10 Hz to 55 Hz) Shock IEC 68-2-27 (30 G) Drop IEC 68-2-32 (1 m) Consult factory for NIST Calibration prices PRODUCT INCLUDES USB cable, (1) set of color-coded (red/black) leads and alligator clips and a thumb drive with DataView® software. IP 40 FEATURES · TRMS voltage recording up to 600 VAC/AC+DC · AC: 64 samples per cycle and DC: 8 samples per second · Programmable storage rates from 8 every second to 1 every day · 4 user selectable storage modes · Stores up to 240,000 measurements in non-volatile memory · Powered by standard alkaline batteries · Lightweight and compact · 5 LED indicators quickly and clearly display logger status · Includes FREE DataView® software for data retrieval, real-time display, analysis and report generation · Optically isolated USB 2.0 communication cable included · EN 61010-1; 300 V CAT IV; 600 V CAT III APPLICATIONS · Surge and Sag recording · Long term supply monitoring · Industrial, commercial and residential monitoring · Monitor voltage harmonics · Find intermittent voltage problems · Machine monitoring CATALOG NO. 2126.05 DESCRIPTION Simple Logger® II Model L261 (1-Channel, TRMS, 600 VAC/AC+DC, DataView® Software) 36 www.aemc.com Technical Assistance (800) 343-1391 © Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved. Vol. 23 Rev.00 02/2023 DATA LOGGERS SIMPLE LOGGER® II TRMS VOLTAGE & CURRENT MODEL L562 Two input channel logger capable of recording Arms, Vrms and VA SPECIFICATIONS MODEL L562 ELECTRICAL Channels Two Connection Current Channel Voltage Channel Input Connection BNC Two recessed banana jacks Input Range (0 to 1) VAC (for use with current probes with a voltage output) (0 to 600) VAC Resolution 0.1 mV 0.1 V Accuracy ((50/60) Hz) (0 to 10) mV unspecified (0 to 5) V unspecified (10 to 50) mV: (5 to 50) V: ± (0.5 % of Reading + 1 mV) ± ( 0.5 % of Reading + 1 V) (50 to 1000) mV: (50 to 600) V: ± (0.5 % of Reading + 0.5 mV) ± (0.5 % of Reading + 0.5 V) Input Impedance 800 k 40 M Maximum Input Voltage 5 Vrms or ± 7.07 V peak (1.2 x 600) V Sample Rate 64 samples/cycle Storage Rate Programmable from 8 every s to 1 every d Storage Modes Recording Length Start/Stop, FIFO, Extended Recording Mode (XRMTM) and Alarm 15 min to 8 weeks, programmable using DataView® IP 40 FEATURES · 2 input channels · Voltage: (0 to 600) VAC TRMS · Current: compatible with AC current probes with voltage outputs (see page 32 - sold separately) · 64 samples per cycle · Records Arms, Vrms & VA (VA displays in DataView® software) · 4 user selectable storage modes · Programmable storage rates from 8 every second to 1 every day · Stores up to 240,000 measurements in non-volatile memory · Powered by standard alkaline batteries · 5 LED indicators quickly and clearly display logger status · Includes FREE DataView® software for data retrieval, real-time display, analysis and report generation · Optically isolated USB 2.0 communication cable included Memory Communication Power Supply Battery Life MECHANICAL 240,000 measurement (512 kB). The recorded data is stored in non-volatile memory and will be retained even if the battery is low or removed. USB 2.0 optically isolated (2) 1.5 V AA-cell alkaline batteries (included) 100 h to > 45 d (Dependent on sample rate and recording length) · Complies with EN 61010-1; 300 V CAT IV; 600 V CAT III (a safety rated current probe is required) APPLICATIONS · Single phase power monitoring · Residential, commercial, industrial, troubleshooting · Find sags and surges / track energy usage Dimensions (5.38 x 2.75 x 1.28) in (137 x 70 x 33) mm Weight (with battery) Case 6.4 oz (181 g) UL94-VO Vibration IEC 68-2-6 (1.5 mm, (10 to 55) Hz) Shock IEC 68-2-27 (30 G) Drop IEC 68-2-32 (1 m) Consult factory for NIST Calibration prices · Start-Stop time stamping PRODUCT INCLUDES Set of color-coded (red/black) 5 ft voltage leads and alligator clips, USB cable, (2) 1.5 V AA batteries, printed quick start guide, USB drive with DataView® software. PROBE MODEL NUMBER CATALOG NUMBER PROBE OUTPUT PROBE RANGE MAX RANGE FOR SLII CABLE DIAMETER BUS BAR OUTPUT SIZE CONNECTION MN261 2115.82 100 mV/A / 10 mV/A (0.1 to 24) A / (0.5 to 240) A 10 A / 100 A 0.78 in (19.8 mm) N/A Lead w/BNC MN379T 2153.02 200 mV/A / 10 mV/A 5 A / 100 A 0.78 in (19.8 mm) N/A SR661 2113.49 1 mV/A 10 mV/A 100 mV/A 1000 A 100 A 10 A 2.13 in (54.1 mm) N/A SEE PAGE 32 FOR MORE COMPATIBLE CURRENT PROBES (SOLD SEPARATELY) CATALOG NO. 2126.35 DESCRIPTION Simple Logger® II Model L562 (2-Channel, TRMS, Voltage & Current, DataView® Software) Lead w/BNC Lead w/BNC Vol. 23 Rev.00 02/2023 Technical Assistance (800) 343-1391 © Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved. www.aemc.com 37 DATA LOGGERS TWO-CHANNEL DC VOLTAGE, CURRENT, PULSE & EVENT MODEL L452 Bluetooth-enabled logger and event counter that records DC voltage, DC current, (4 to 20) mA or pulse counts Real-time display! Powered by batteries or through a USB SPECIFICATIONS MODEL ELECTRICAL Channels Input Measurements Range Accuracy (% of Reading) Resolution Input Impedance Sample Rate Sample Period Storage Modes Recording Length Memory Communication Power Supply Battery Life MECHANICAL Dimensions Weight (with battery) Vibration Shock ENVIRONMENTAL Operating Temperature Humidity Ingress Protection IP 20 with terminals L452 DC Current (4 to 20) mA Two* Six-pin terminal strip DC Voltage Event Pulse 100 mV, 1 V, 10 V N/A ± (0.25 % + 5 ct) ± (0.5 % + 1 ct) N/A 0.01 mA 0.1 mV, 1 mV, 10 mV N/A 100 1 M N/A 5 samples/s 16 samples/s 100 samples/s DC inputs: 200, 400, 600, or 800 ms; or from 1 to 60 s Pulse detection: 10 ms Start/Stop (ends when memory is full or when the recording stop time is reached, whichever comes first) 10 min to 1 y, set via instrument front panel or through DataView® 32 MB internal Flash memory (up to 1024 logging sessions, 16 M samples) Bluetooth 2.1, Class 1 or USB 2.0 External: via USB connector Internal: (2) AA NiMH rechargeable batteries (charges through USB port) Up to 180 d (dependent on storage rate/recording length) (1.28 x 2.58 x 5.4) in (32 x 65 x 137) mm 6.7 oz (190 g) with batteries IEC 68-2-6 (1.5 mm, (10 to 55) Hz) IEC 68-2-27 (30 G) (32 to 122) °F (0 to 50) °C (16 to 85) % IP40 (instrument alone); IP20 (instrument with terminal strip) *Both channels must have the same input type. Consult factory for NIST Calibration prices PRODUCT INCLUDES 6 ft USB cable, US 120 V wall-to-USB plug, 6-pin screw terminal block, (2) AA rechargeable NiMH batteries, a printed quick start guide, a USB drive containing DataView® software and user manual. 38 www.aemc.com Technical Assistance (800) 343-1391 © Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved. Vol. 23 Rev.00 02/2023 DATA LOGGERS TWO-CHANNEL DC VOLTAGE, CURRENT, PULSE & EVENT FEATURES · Multiple data input types. The L452 can log DC voltage, DC current, 4 mA to 20 mA, pulse counts, or events. Measurements can be performed directly on the instrument, or through a variety of sensors. This data is stored in the instrument's large 32 MB internal Flash memory. · Expanded user interface. You can set up the instrument and view real-time measurement data through the front panel LCD screen and input buttons. The L452 features an on-board menu-based interface for navigating measurement data and selecting configuration options. · Enhanced DataView® support. The instrument connects to a PC using either Bluetooth or USB. Once connected, logged data can be downloaded, analyzed, and formatted into reports using the DataView® Data Logger Control Panel. This Control Panel also enables users to change settings on the instrument, view real-time measurements, schedule recording sessions, and perform other configuration tasks. FRONT PANEL & FUNCTIONAL DISPLAYS Navigation button: Left Power button: ON/OFF INSTRUMENT CONFIGURATION OL 1 24.5 mV 2 91.8 mV Instrument configuration parameters can be set through the front panel interface. ALARM TRIGGERS Navigation button: Up Navigation button: Right Enter button Navigation button: Down BLUETOOTH ENABLED/VISIBILITY Bluetooth: Enabled Visibility: Visible Enable and configure Bluetooth's functionality. RECORDING SESSION UPPER LIMIT: 50.00 degC LOWER LIMIT: -10.00 degC Allows you to set the upper and/or lower alarm trigger limits. MIN/MAX MEASUREMENTS RECORDING SESSIONS: 4 FREE MEMORY: 29.66 MB Displays the number of recording sessions currently stored in memory. It also shows the amount of free memory left for storing additional recording sessions. EVENT MEASUREMENT DATA CATALOG NO. 2153.51 1 2.54 m3/s 1 MAX 2.54 m3/s 2 MIN 0.22 m3/s For analog input types, this screen displays the session's MIN/MAX measurement values for each channel. For event input, the Channels 1 & 2 measurement graphic data screen appears. DESCRIPTION Data Logger Model L452 (2-Channel, w/LCD, 100 mV/1 V/10 VDC, (4 to 20) mADC, Event & Pulse, DataView® Software) Vol. 23 Rev.00 02/2023 Technical Assistance (800) 343-1391 © Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved. www.aemc.com 39 DATA LOGGERS THREE- AND FOUR- CHANNEL AC CURRENT MODELS DL913 & DL914 Waterproof three and four channel NEW DL914 AC current data loggers with flexible sensors SPECIFICATIONS MODELS DL913 / DL914 ELECTRICAL Channels 3 (DL913) / 4 (DL914) Inputs Measurement Ranges Accuracy ((50/60) Hz) Resolution Frequency Storage Rate Recording Length Memory MiniFlex® 300 AAC / 3000 AAC 300 A range 3000 A range (0.50 to (90.0 to (4.00 to (90.0 to (0.900 to 99.99) A 360.0) A 99.99) A 999.9) A 3.600) kA ± (1 %r + 10 D) ± (1 %r + 4 D) ± (1 %r + 10 D) ± (1 %r + 5 D) ± (1 %r + 4 D) 0.01 A 0.1 A 0.01 A 0.1 A 1 A (45 to 65) Hz ± 0.1 Hz Normal recording mode: Once per second Extended recording mode: Four per aggregation period Battery Power: 4 d with no missing samples (normal recording mode) 7 to 30 d depending on the selected aggregation period (extended recording mode) External Power: 365 d Internal 8 GB SAFETY R ATIN G FEATURES with USB cap on and cover closed · Simple-to-use, 3 (DL913) and 4 (DL914) channel AC current data loggers · 4th channel for neutral current monitoring (Model DL914) · Includes 3 (DL913) or 4 (DL914) integral 24-inch flexible current sensors · Current measurements from 500 mA up to 3600 A Communication Battery Charge Time Power Supply Battery Life MECHANICAL USB, Wi-Fi via router (Ethernet), or Wi-Fi Direct 10 h maximum (Wi-Fi off) Internal: 4.2 A·h NiMH rechargeable battery pack External: USB connection Normal recording mode: 4 d Extended recording mode: 7 to 30 d* (*Depending on the selected aggregation period) Reference user manual for in-depth information on the battery life, aggregation period, storage interval, and recording modes. Dimensions Weight (with battery) Sensor/Cable Length Max. Conductor (5.9 x 5.9 x 3.57) in (150 x 150 x 91) mm w/o sensors DL913: 2.2 lbs (1 kg) / DL914: 2.42 lbs (1.1 kg) 3 (DL913) or 4 (DL914) integral 24 in (610 mm) MiniFlex® probes with 6.5 ft (2 m) leads 7.64 in (194 mm) Case UL94-V0 Flame retardant Vibration IEC 68-2-6 (1.5 mm, (10 to 55) Hz) Shock IEC 68-2-27 (30 G) Drop IEC 68-2-32 (3.3 ft [1 m] in the most severe position without permanent mechanical damage or functional deterioration) ENVIRONMENTAL Operating/ Storage Temperature Relative Humidity (14 to 122) °F (-10 to 50) °C / (-40 to 158) °F (-40 to 70) °C Operation: up to 85 % RH (non-condensing) Storage: up to 95 % RH Consult factory for NIST Calibration prices · LCD displays real-time measurements and parameters such as memory, power, and communication status · Front panel navigation of configuration options and measurement screens · Built-in web server for remote monitoring · Extended recording mode for increased battery life · Battery and/or USB powered options · Frequency measurements · Wi-Fi and USB communications · Waterproof IP67 rated (USB cap on, cover closed) APPLICATIONS · Single/Split-phase and 3- or 4-phase load monitoring · Neutral and ground current monitoring · Intermittent problem detection · Machine load monitoring / Load profiling · Fault current detection PRODUCT INCLUDES Includes small classic tool bag, 10 ft USB Type A to Type B cable, (4) stainless steel mounting brackets, (4) stainless steel M4 machine screws, USB power adapter, quick start guide, and USB thumb drive with DataView® software and user manual. CATALOG NO. DESCRIPTION 2153.61 Data Logger Model DL913 (3-channel, TRMS, MiniFlex® 300/3000 A, Wi-Fi, DataView® Software) 2153.62 Data Logger Model DL914 (4-channel, TRMS, MiniFlex® 300/3000 A, Wi-Fi, DataView® Software) 40 www.aemc.com Technical Assistance (800) 343-1391 © Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved. Vol. 23 Rev.00 02/2023 DATA LOGGERS SIMPLE LOGGER® DATA LOGGERS MODELS SL01 TO SL13 Small AC and DC simple loggers can be ready to go in minutes with just a few parameters to set up MODELS SL20 & SL50 Log DC Current and Temperature SL10 SL12 SL20 SL01 SPECIFICATIONS MODELS VOLTAGE Range Resolution Accuracy Maximum Input Voltage Input Impedance Power Supply Power Consumption SL01 SL10 SL11 SL12 SL13 (0 to 5) VAC 10 mV ± (0.5 % of Reading + 50 mV)* ± 100 mVDC 0.1 mV ± (0.5 % of Reading + 0.5 mV)* ± 1 VDC 1 mV ± (0.5 % of Reading + 5 mV)* 60 VDC ± 10 VDC 10 mV ± ( 0.5 % of Reading + 50 mV)* ± 50 VDC 50 mV ± (0.5 % of Reading + 250 mV)* 800 K Internal: (2) 1.5 V AA non-rechargeable batteries External: USB 2.0 (computer or other USB power source) Internal power: 1 mA (average) / External power: 100 mW *Accuracy is specified with the 10-point filter selected to reduce noise. Consult factory for NIST Calibration prices SL11 SL20 CURRENT ± 20 mA 0.02 mA ± (0.5 % of Reading + 0.1 mA)* 25 mADC 49 SL13 SL50 IP 40 FEATURES · Simple one button operation · Quick two wire input connection · User configurable scaling, units of measure and recording length · Stores up to 4 million measurements · Data analysis software included · Software provides real-time trend graph display, data download, analysis and report generation · Micro-B USB cable included MODEL Range Resolution Thermocouple Type: J K TEMPERATURE (-346 to 2192) °F (-328 to 2502) °F (-210 to 1200) °C (-200 to 1372) °C N (-328 to 2372) °F (-200 to 1300) °C SL50 T (-328 to 752) °F (-200 to 400) °C 0.1 °C E (-328 to 1832) °F (-200 to 1000) °C R S (32 to 3200) °F (0 to 1760) °C Accuracy Below -148 °F (-100 °C): ± (0.4 % of Reading + 9 °F [5 °C])* (-148 to 212) °F (-100 to 100) °C: (0.3 % of Reading + 7.2 °F [4 °C])* (32 to 212) °F (0 to +100) °C: ± (0.3 % of Reading + 18 °F [10 °C])* Above 212 °F (100 °C): ± (0.2 % of Reading + 5.4 °F [3 °C])* Above 212 °F (100 °C): ± (0.2 % of Reading + 14 °F [8 °C])* Maximum Input Voltage Input Impedance 1 V 800 K Power Supply Internal: (2) 1.5 V AA non-rechargeable batteries External: USB 2.0 (computer or other power source, when powered by the USB the battery is automatically disconnected) Power Consumption Internal power: 1 mA (average) / External power: 100 mW *Accuracy is specified with the 10-point filter selected to reduce noise. Consult factory for NIST Calibration prices Vol. 23 Rev.00 02/2023 Technical Assistance (800) 343-1391 © Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved. www.aemc.com 41 DATA LOGGERS SIMPLE LOGGER® DATA LOGGERS SIMPLE LOGGER CONTROL PANEL The Simple Logger Control Panel allows you to configure how data measured by these instruments is recorded and displayed. The available settings depend on which model is connected to the computer. The following table shows which configuration options are available for each model. FEATURE SL01 SL10 SL11 SL12 SL13 SL20 SL50 Set up recording ó ó ó ó ó ó ó Define units ó ó ó ó ó ó ó Set instrument clock ó ó ó ó ó ó ó Erase instrument memory ó ó ó ó ó ó ó Scaling ó ó ó ó ó ó Filtering ó ó ó ó ó ó ó Thermocouple type ó Cold Junction Compensation ó Current configuration of a logger Typical real-time trend graph CATALOG NO. 2156.01 2156.10 2156.11 2156.12 2156.13 2156.20 2156.50 DESCRIPTION Simple Logger® Model SL01 (Low Voltage, 5 VAC) Simple Logger® Model SL10 (Voltage, 100 mVDC) Simple Logger® Model SL11 (Voltage, 1 VDC) Simple Logger® Model SL12 (Voltage, 10 VDC) Simple Logger® Model SL13 (Voltage, 50 VDC) Simple Logger® Model SL20 (Current, 4 to 20 mADC) Simple Logger® Model SL50 (Temperature, Thermocouple) 42 www.aemc.com Technical Assistance (800) 343-1391 © Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved. Vol. 23 Rev.00 02/2023 DIGITAL MULTIMETERS SEE WEBSITE FOR PRICING AND AVAILABILITY: WWW.AEMC.COM DIGITAL MULTIMETERS 5000 SERIES MODELS 5212, 5217, 5231 & 5233 Compact and simple to use, these multimeters with a large backlit display and noncontact voltage detection are exceptional products and a great value for today's market SPECIFICATIONS MODELS GENERAL True RMS AC Bandwidth Auto/Manual Ranging LCD Display Auto/Manual Range Select Voltage AC/DC Current AC/DC µAmps AC/DC Resistance Frequency/Duty Cycle Capacitance Temperature Continuity with Beeper Diode Test V Low Z Non Contact Voltage Detection (NCV) Max / Min / Max-Min REL OTHER FEATURES Display Hold Flashlight Backlight Removable Holster Magnetic Hanger Auto Power OFF Auto Power OFF Disable Power Supply Battery Life Low Battery Indication Direct Fuse Access Drop Resistant Operating Temperature Range Double Insulated WARRANTY/SAFETY Warranty Ingress Protection Safety Consult factory for NIST Calibration prices 5212 5217 5231 5233 Yes 1000 Hz Yes 4000-count 6000-count 6000-count + 61 segment bargraph Yes 600 V 750 VAC / 1000 VDC 6 ranges / 60 mV to 1000 V; Resolution: 0.01mV 4 A / 10 A 6 A /10 A With 1 mV/A clamp: 600 A 2 ranges / (6 to 10) A Resolution: 0.1 A Resolution: 0.001 A 400 / 4000 µA 600 / 6000 µA 40 M 60 M 6 ranges / 60 M; Resolution: 0.1 1000 Hz/Yes 3 ranges: up to 3 kHz/Yes 100 mF 6 ranges / 1000 µF; Resolution: 0.01 nF (-61 to 2192) °F (4 to 1400) °F (-55 to 1200) °C (-20 to 760) °C Yes Yes Yes 4 ranges / 60 mV to 1000 V; Resolution: 0.01 mV Yes/Red flashing display with buzzer Yes/Red display No / No / No Yes / Yes / Yes No / No / No Yes / Yes / No No Yes No Yes Yes Yes Yes in the holster (2) 1.5 V AA 500 h Yes 6.56 ft (2 m) (-4 to 122) °F (-20 to 50) °C Yes Yes Blue/Red Yes Yes Yes Yes Yes No No No 9 V > 100 h Yes 3.28 ft (1 m) (32 to 122) °F (0 to 50) °C 3 y 600 V CAT III 2 y IP54 1000 V CAT III, 600 V CAT IV 44 www.aemc.com Technical Assistance (800) 343-1391 © Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved. Vol. 23 Rev.00 02/2023 DIGITAL MULTIMETERS 5000 SERIES Non-contact detection of network voltage (NCV Function-AC only) FUNCTIONAL DISPLAYS Display Hold enabled Relative mode active Auto measurement MAX, MIN or MAX minus MIN selected Auto Power OFF Low battery indication SAFETY 5212 & 5217 R ATIN G 5233 IP MODELS 5231 & 5233 54 FEATURES Analog & Digital display · AC/DC current up to (10 or 600) A with a current clamp giving direct readings (Model 5231) · High sensitivity with a resolution of 0.01 mV MAX/MIN selected Relative mode active AC/DC voltage or current · Withstands overloads up to 8000 V · VLowZ function detects and eliminates ghost voltages by placing a burden on the circuit · Multi-position mounting Auto Range Display Hold enabled Buzzer indication · Battery life extended with "sleep mode" feature · Backlight screen and flashlight (Models 5212 & 5217) · Displays MAX, MIN and MAX-MIN (Models 5217; Model 5233 displays MAX & MIN only) · Displays relative measurement (Models 5217 & 5233) · Measures temperature (Models 5217 & 5233) · Measures frequency and duty cycle (Models 5217 & 5233) AC/DC voltage or current Diode test selected Continuity selected M, k: Decimal prefix Hz: Frequency selected °F, °C: Temperature %: Duty cycle selected A, V: Amps or Volts F: Farads for capacitance n, m, µ: Decimal prefix °F, °C: Temperature Units of measure Hz: Frequency selected Low battery indicator Auto Power OFF Diode test selected PRODUCT INCLUDES 5212 & 5217 Soft carrying pouch, set of (2) color-coded (red/black) leads, (2) 1.5 V AA batteries and user manual. THERMOCOUPLE ADAPTER Included with Model 5217 5231 Soft carrying case, set of (2) 5 ft color-coded leads (red/black) with needle tip (1000 V CAT IV 15 A), and user manual. 5233 Soft carrying case, set of (2) 5 ft color-coded leads (red/black), adapter - banana (male) to mini (female) with K-type thermocouple, and user manual. CATALOG NO. 2154.07 2154.09 2125.64 2125.65 DESCRIPTION DMM Model 5212 (TRMS, 4000-cts, NCV, V, A, AC/DC, Ohm, Auto Hold) DMM Model 5217 (TRMS, 6000-cts, NCV, V, A, AC/DC, Ohm, T, Frequency, Auto Hold) DMM Model 5231 (TRMS, 6000-cts, V, AC/DC, Ohm, CT, NCV) DMM Model 5233 (TRMS, 6000-cts, V, A, AC/DC, Cap, Ohm, T, NCV) Vol. 23 Rev.00 02/2023 Technical Assistance (800) 343-1391 © Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved. www.aemc.com 45 DIGITAL MULTIMETERS 3000 SERIES 3Yr MODELS MTX 3290 & 3291 A compact, rugged, comfortable to grip, waterproof (to IP67 standard) meter SPECIFICATIONS MODELS ELECTRIC DC, AC & AC+DC Voltages MTX 3290 60 mV to 600 V MTX 3291 60 mV to 1000 V Voltage DC Accuracy ± 0.3 % ± 0.05 % AC & AC+DC Bandwidth 20 kHz 100 kHz DC, AC & AC+DC Current 600 µA to 10 A / 20 A (30 s max) (MTX 3291) Current DC Accuracy ± 0.08 % Frequency 60 Hz to 600 kHz Resistance 600 to 60 M Audible Continuity 600 signal < 30 ± 5 < 5 V Diode Test 3 V with 1 mV resolution Capacitance 6 nF to 60 mF Temperature Pt100/1000 (-328 to 1472) °F (-200 to 800) °C Temperature K/J TC OTHER FUNCTIONS MIN/MAX/PEAK Time/date-stamped MAX/MIN/AVG or PEAK ±, on all functions Relative Mode (Rel) PWM Filter V-Output Clamp Function for Direct Reading Secondary Functions or Measurements Relative value + measured reference value on secondary display (MTX 3291) 4th-order 300 Hz low-pass filter for measuring variable speed drives with asynchronous motors Integration of the ratio: 1, 10, 100, 1000 mV/A dBm and VA resistive power, +/- duty cycle, and pulse width (MTX 3291) SPEC Mode GRAPH Center Zero Selectable or automatic (MTX 3291) bargraph for VDC and ADC Memory GENERAL Display LCD with backlighting (MTX 3291) and digits 14 mm high; Dual-line 60,000 (MTX 3291) or 6000-count display Communication USB optical connector & SX-DMM software (included) Power Supply (4) AA batteries (included) or NiMH batteries Environment Storage: (-4 to 158) °F (-20 to 70) °C Operation:( 32 to 104) °F (0 to 40) °C Dimensions (7.72 x 3.54 x 1.85) in (196 x 90 x 47) mm Weight 20 oz (570 g) Consult factory for NIST Calibration prices SAFETY R ATIN G MTX 3290 MTX 3291 IP 67 MTX 3290 only FEATURES · Easy-to-read (2.75 x 2.04) in (70 x 52) mm backlit LCD screen · On screen connection indicator · Current: auto-ranging up to 10 A · Secondary measurements in addition to the main measurement to facilitate analysis · MIN/MAX and AVG data with relative time/datestamping and voltage and current peaks · SX-DMM software for real-time processing of the data on a PC (MTX 3291) · Powered by four standard AA batteries or four NiMH batteries rechargeable available with optional external charging module PRODUCT INCLUDES Set of color-coded (red/black) safety leads, set of (2) color-coded (red/black) test probes, (4) 1.5 V AA alkaline batteries (installed), multilingual operation instructions, quick start guide, and a USB drive with user manual. Model MTX 3291 also includes a soft carrying case, USB cable, and USB drive with SX-DMM software. CATALOG NO. 2154.01 2154.02 DESCRIPTION DMM Model MTX 3290 (ASYC IV, TRMS, 6000-cts, Digital LCD) DMM Model MTX 3291 (ASYC IV, TRMS, 60,000-cts, USB, Backlit, Digital LCD) 46 www.aemc.com Technical Assistance (800) 343-1391 © Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved. Vol. 23 Rev.00 02/2023 DIGITAL MULTIMETERS 3000 SERIES 3Yr MODELS MTX 3292B & 3293B Portable multimeter measuring resistance, capacitance, temperature, duty cycle, pulse counts and frequency MTX 3292B MTX 3293B SPECIFICATIONS SAFETY MODELS MTX 3292B MTX 3293B ELECTRICAL R ATIN G DC, AC & AC+DC Voltages 100 mV to 1000 V * Voltage DC Accuracy ± 0.03 % ± 0.02 % ** AC & AC+DC Bandwidth 100 kHz 200 kHz DC, AC & AC+DC Current Current DC Accuracy 1000 µA to 10 A / 10 to 20 A (30 s max) ± 0.01 % *Bluetooth Communication for Models 3292B-BT & 3293B-BT only **AndroidTM App available on Google Play for Models 3292B-BT & 3293B-BT Frequency Resistance Audible Continuity Diode Test 10 Hz to 5 MHz 100 to 100 M 1000 signal < 20 < 3.5 V Diode 0 to 2.6 V < 1 mA + Zener Diode or LED 0 to 20 V < 11 mA FEATURES MTX 3292B & MTX 3293B · Easy-to-read 320 x 240 pixel color matrix graphical screen with black background Capacitance Temperature Pt100/1000 Temperature K/J TC OTHER FUNCTIONS MIN/MAX/PEAK Relative Mode (Rel) PWM Filter V/A-Output Clamp Function for Direct Reading Secondary Measurements SPEC Mode 1 nF to 10 mF (-328 to 1472) °F (-200 to 800) °C (-40 to 2192) °F (-40 to 1200) °C SURV time/date-stamped MAX/MIN/AVG or PEAK ± on all functions Relative value REF-delta unit or on 3 displays + main measurement 4th-order 300 Hz low-pass filter for measuring variable speed drives with asynchronous motors Programmable ratio 3 measurements + main measurement Display of measurement tolerance: Smin, Smax · Trace, cursors and zoom on recordings · Programmable storage rate · Stores up to 30,000 measurements (MTX 3293B) · On screen connection indicator · USB or Bluetooth Class II communication available as an option · NiMH AA rechargeable battery · No downtime: instrument operates while charging PRODUCT INCLUDES MTX 3292B & MTX 3292B-BT, MTX 3293B & MTX 3293B-BT GRAPH Center Zero Memory GENERAL Display Trends of main measurements < 60 s + Zoom + Cursor Automatic trend bargraph 10,000 measurements 30,000 measurements Color graphical display (70 x 52) with backlighting on four-line 100,000-count display Soft carrying case, set of (2) color-coded (red/black) safety leads, set of (2) color-coded (red/black) test probes, printed quick start guide, (4) NiMH 2400 mA·h 1.5 V rechargeable batteries (installed), optical USB cable, USB Type A charger, USB charging cable and USB drive with SX-DMM software. Communication USB optical connector or Bluetooth Class II (optional) & SX-DMM software (included) Power Supply Charger or (4) AA batteries or NiMH batteries (included) Environment Storage: (-4 to 158) °F (-20 to 70) °C Operation: (32 to 104) °F (0 to 40) °C Dimensions (7.72 x 3.54 x 1.85) in (196 x 90 x 47.1) mm Weight 20.1 oz (570 g) Consult factory for NIST Calibration prices SHOWN: MTX 3293B CATALOG NO. 2154.03 2154.04 2154.05 2154.06 DESCRIPTION DMM Model MTX 3292B (ASYC IV, TRMS, 100,000-cts, USB, Color Graphical Display) DMM Model MTX 3293B (ASYC IV, TRMS, 100,000-cts, USB, Color Graphical Display) DMM Model MTX 3292B-BT (ASYC IV, TRMS, 100,000-cts, Bluetooth, USB, Color Graphical Display) DMM Model MTX 3293B-BT (ASYC IV, TRMS, 100,000-cts, Bluetooth, USB, Color Graphical Display) Vol. 23 Rev.00 02/2023 Technical Assistance (800) 343-1391 © Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved. www.aemc.com 47 DIGITAL MULTIMETERS 3000 SERIES FUNCTIONAL DISPLAYS The TRMS measurements of AC voltages and currents are also accurate on non-linear signals MTX 3292B & MTX 3293B COLOR MATRIX GRAPHICAL SCREENS SETUP MENU Configuration of measurements MEASUREMENT Configuration of the measurement parameters MEM Storing of the measurements recording mode HOLD Management and hold of the display MTX 3290 & MTX 3291 BACKLIT LCD SCREENS MAX/MIN AVG Displays maximum, minimum and average values PEAK MODE Example of screen showing Peak+value REL MODE Displays relative values with respect to referenced measured value 48 www.aemc.com Technical Assistance (800) 343-1391 © Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved. Vol. 23 Rev.00 02/2023 ELECTRICAL TEST TOOLS SEE WEBSITE FOR PRICING AND AVAILABILITY: WWW.AEMC.COM ELECTRICAL TEST TOOLS PHASE AND MOTOR ROTATION METERS MODELS 6608, 6609 & 6610 Ideal for installing rotating machinery or motors, and checking generator output phase direction SPECIFICATIONS MODELS 6608 6609 6610 ELECTRICAL Operating Voltage Frequency Range Power Supply MECHANICAL Dimensions Weight (40 to 850) VAC between phases With leads connected: (40 to 600) VAC between phases (75 to 1000) VAC Static induction (15 to 400) Hz (45 to 65) Hz Self-powered via the measurement inputs (1) 9 V Alkaline battery (included) (5.1 x 2.7 x 1.3) in (130 x 69 x 33) mm 4.5 oz (128 g) 6 oz (170 g) (5.0 x 2.8 x 1.8) in (127 x 71 x 46) mm 13.4 oz (380 g) ENVIRONMENTAL Operating Temperature Storage Temperature SAFETY Safety Rating / Ingress Protection Electrical Safety (32 to 104) °F (0 to 40) °C (-4 to 122) °F (-20 to 50) °C; < 80 % RH IEC 61010-1, DIN VDE 0411; IEC 61557-7, DIN VDE 0413-7; Tightness / IP40 600 V CAT III (14 to 122) °F (-10 to 50) °C; max. 80 % RH (-4 to 140) °F (-20 to 60) °C; max. 80 % RH EN 61010-1, EN 61326-1 1000 V CAT III; 600 V CAT IV PRODUCT INCLUDES 6608 & 6609 Soft carrying case, (3) 4 ft color-coded (red/black/blue) test leads, (3) color-coded (black) alligator clips and user manual. 6610 Soft carrying case, meter with attached test leads (black, red & blue) with alligator clips, 9 V battery and user manual. 6608 case 6610 case 6608 6609 6610 SAFETY IP 40 R ATIN G 6610 only Except 6610 FEATURES · Voltage sensing detector clips no metal contact points to promote greater safety (Model 6610) · Indication of live phase presence or phase absence · Designed for checking a wider range of 3-phase power supply from 75 VAC to 1000 VAC (Model 6610) · Determination of a motor's rotation direction (Model 6609) · Automatic testing as soon as the instrument is connected · Terminals and cables identified by color-coding to simplify connection (test leads are attached to Model 6610) · Phase rotation indicators (Model 6608) · Phase and motor rotation indicators (Models 6609 & 6610) · Color-coded leads (red, black, blue) and alligator clips (black) · Color-coded jacks for common U.S. phase colors · Line supplied - no battery needed (Model 6608) · Protected internally by high impedance circuit to limit the current to user safe limits CATALOG NO. 2121.10 2121.11 2121.12 DESCRIPTION Phase Rotation Meter Model 6608 Phase & Motor Rotation Meter Model 6609 Phase Rotation Meter Model 6610 (Non-contact) 50 www.aemc.com Technical Assistance (800) 343-1391 © Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved. Vol. 23 Rev.00 02/2023 ELECTRICAL TEST TOOLS SPLITTER, TESTER AND DETECTOR AC LINE SPLITTER MODEL ALS-1 For use with clamp-on meters and multimeters using current probes FEATURES · Avoids splitting lines - makes reading current easy · Increases sensitivity of clamp-on current probes and clamp-on meters ten times in X10 mode · Direct reading X1 mode · Voltmeter input jacks · Integral ground conductor · Facilitates reading current draw of device plugged into it · Facilitates reading current draw through extension cords · 120 V, 15 A capacity NON-CONTACT AC VOLTAGE DETECTOR MODEL NC-1 SPECIFICATIONS MODEL NC-1 Voltage Sensitivity (120 to 240) VAC Frequency (50/60) Hz Detection Distance < 5 mm Over Voltage 600 V CAT III Power Supply (2) 1.5 V AAA Alkaline (included) Electrical Safety For indoor use and in accordance with over voltage 600 V CAT III, Pollution Degree 2 ALS-1 NC-1 CATALOG NO. 2121.05 2121.09 DESCRIPTION AC Line Splitter Model ALS-1 Non-Contact AC Voltage Detector Model NC-1 Vol. 23 Rev.00 02/2023 Technical Assistance (800) 343-1391 © Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved. www.aemc.com 51 ELECTRICAL TEST TOOLS NON-CONTACT HIGH VOLTAGE DETECTOR MODEL 275HVD Warns the operator of live conductors with the use of its detection sensor SPECIFICATIONS MODEL 275HVD ELECTRICAL Detection Frequency (45 to 70) Hz Ranges Detection 240 V, 2 kV, 6 kV, 11 kV, 22 kV, 33 kV, 132 kV, 275 kV Selection range is detected at approximately 10 in (25 cm) from the voltage. Greater detection distances can be obtained at lower voltage positions Power Supply (3) 1.5 V C cell batteries (included) MECHANICAL Self Test User selectable Indicators Bright red LED and audible buzzer ENVIRONMENTAL Operating Temperature (5 to 130) °F (-15 to 55) °C Storage Temperature (-4 to 150) °F (-20 to 65) °C Humidity Up to 93 % RH @ 104 °F (40 °C) Electrical Safety EN 61326-1, EN 61000-4-2, EN 61000-4-3, EN 55011 IP 65 Note: Not designed to work on shielded cable or enclosure. FEATURES · Non-contact high voltage detector · Wide range of detection; 80 V to 275 kV; one instrument fits all applications · Eight switch-selectable voltage sensitivity ranges · Audible and visual (LED) indication of live voltage · Self-test ensures that all system functions and indicators are working properly by energizing the complete system · Designed for use with hot sticks incorporating a shotgun adapter · Lightweight, minimizes sway at the end of long hot sticks · Suitable for indoor and outdoor use · Easy access to batteries PRODUCT INCLUDES Hard carrying case, universal spline for hot stick connection, (3) C cell batteries, shotgun adapter and a user manual. Note: Hot stick not supplied ACCESSORIES/ REPLACEMENTS Catalog #5100.03 Battery housing with o-ring and spring Catalog #5100.08 Metal Universal Spline Adapter Catalog #2131.36 Replacement Carrying Case CATALOG NO. 2131.12 DESCRIPTION Non-Contact High Voltage Detector Model 275HVD (240 V to 275 kV, Manual self-test) 52 www.aemc.com Technical Assistance (800) 343-1391 © Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved. Vol. 23 Rev.00 02/2023 ELECTRICAL TEST TOOLS VOLTAGE ABSENCE TESTERS (VATs) MODEL CA 773 An essential tool for electricians to ensure no voltage is present before working on any electrical installation connected to the network SPECIFICATIONS MODEL ELECTRICAL Display Voltage Absence Testing (VAT) Voltage LEDs CA 773 LEDs + backlit digital display 12 VAC U 1000 VAC; 12 VDC U 1400 VDC (12 to 1000) VAC; (12 to 1400) VDC LEDs + backlit digital display Frequency Impedance Max. Peak Current Polarity Indication Redundant Hazardous Voltage Indication Stray Voltage Detection GFI Tripping Phase/Neutral Identification CONTINUITY & RESISTANCE Buzzer Trigger Threshold Extended Continuity Test (Resistance) Test Current / Open-circuit Voltage Phase Rotation Ph/Ph Voltage Buzzer Electrical Safety Operating Temperatures Power Supply Environment Dimensions Weight (1.0 to 299.0) VAC/DC (300 to 1,000) VAC / 1,400 VDC DC, (16.67 to 800) Hz > 500 k 3.5 mA RMS Yes The ELV (Extra-Low Voltage) LED indicates that the voltage is higher than the SELV (Safety Extra-Low Voltage) with rate at flashing proportional to the voltage level Yes (by low-impedance load switching) Up to 30 mA Above 50 V (45 to 65) Hz; Above 150 V (16.67 to 45) Hz 100 typical (150 max.) 0.5 to 2999 k 1 mA / 3.3 V 2-wire method with microprocessor 50 V U 1000 VAC (45 to 400) Hz Intermittent beep for Voltage Detection Continuous beep for continuity IEC 61243-3, EN 61243-3, IEC 61010 1000 V CAT IV (5 to 113) °F (-15 to 45) °C (Class N) (2) AA batteries (included) or NiMH batteries Storage: (-40 to 158) °F (-40 to 70) °C (7.72 x 3.54 x 1.85) in (196 x 90 x 47) mm 1.25 lb (567 g) PRODUCT INCLUDES Set of removable test probes Ø 2 mm with crystal safety cover, probe-tip protector, velcro strap, (2) 1.5 V AA batteries, and a multilingual user manual. CA 773 IP 65 FEATURES · Full autotest · Voltage detection, LED display: 12 VAC U 1000 VAC 12 VDC U 1400 VDC · Frequency: DC, (16.67 to 800) Hz · Detection of stray voltages · Unipolar phase detection (a single contact) · Two-pole phase-sequence testing with 2-wire method = a third hand is not required · Continuity test with audible and visual indication (R < 100 ) · Extended continuity test with visual indication for: R < 0.5 to 2.999 k · RCD trip test · Complies with EN 61243-3 & IEC 61010 1000 V CAT IV · Battery life > 2500 x 10 s measurements · Removable lead and test probe · Delivered complete and ready to use CATALOG NO. 2121.15 DESCRIPTION Voltage Tester Model CA 773 (LED & backlit display, VAT 12 VAC U 1000 VAC; 12 VDC U 1400 VDC, Absence of Voltage) Vol. 23 Rev.00 02/2023 Technical Assistance (800) 343-1391 © Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved. www.aemc.com 53 ELECTRICAL TEST TOOLS TACHOMETERS MODELS CA 1725 & CA 1727 Simple to use and offers numerous measurement capabilities with or without contact SPECIFICATIONS MODELS CA 1725 CA 1727 MEASUREMENTS Rotational Speed Function Range: (6 to 100,000) RPM Resolution: (0.0006 to 6) RPM depending on range Linear Speed Function Range: (0.1 to 10,000) m/min or ft/min Resolution: (0.0006 to 6) m/min or ft/min depending on range Frequency Function Range: (0.1 to 10,000) Hz Resolution: (0.0004 to 0.4) Hz depending on range Period Function Range: (0.1 to 10,000) ms Resolution: (0.0003 to 0.3) ms depending on range Duty Cycle Function Range: (10 to 10,000) % Resolution: (0.1 to 1) % depending on range Count Function Range: 0 to 99,999 events; Accuracy: ± 1 event (Model CA 1727) GENERAL Power Supply 9 V Alkaline battery (included) Battery Life 250 x 5 min measurements with optical sensor; 600 x 5 min measurements with external sensor Data Storage 4000 measurements (Model CA 1727) Dimensions (8.5 x 2.83 x 1.85) in (216 x 72 x 47) mm Weight 8.8 oz (250 g) Weatherproofing IP51 Environment Storage: (-4 to 158) °F (-20 to 70) °C 95 % RH; Operation: (32 to 131) °F (0 to 55) °C 90 % RH OPTICAL SENSOR Reflective Area (10 to 90) % of the target area Measurement Distance (0.4 x 19.7) in (1 to 50) cm The maximum distance is given for a reflective adhesive strip with a minimum area of 10 cm2. Measurement Angle ± 15 ° in relation to the perpendicular of the reflective surface. MECHANICAL Adapter Pressure on Moving Part Service Life End-fittings: elastomer with a durometer hardness of 80 Between 2 and 40 N; maximum speed: 10,000 RPM Approx. 1000 h at 3000 RPM with a pressure of 20 N Conical End-fitting Accessory Minimum diameter of measurement shaft: 0.2 in (5 mm) Cylindrical End-fitting Accessory Speed measurements on shafts with a diameter greater than 0.2 in (5 mm) or flat-ended shafts End-fitting Accessory with Wheel Wheel diameter: 1.19 in (30 mm); Wheel development: 3.94 in ± 0.004 in (99 mm ± 0.1 mm) Consult factory for NIST Calibration prices IP 51 CA 1725 CA 1727 FEATURES · Measurements up to 100,000 RPM · Multiple functions and automatic routines for data acquisition and storage: measurement of rotational speed, linear speed, count, frequency and period · Extensive programming possibilities · Digital display with analog bargraph · USB interface for processing results on a PC (Model CA 1727) · Includes TachoGraph software on CD-ROM (Model CA 1727) download memory only · Stores up to 4000 measurements results (Model CA 1727) ACCESSORIES MECHANICAL ACCESSORIES KIT Catalog #1749.02 Mechanical adapter, calibrated wheel, conical and cylindrical end fitting PRODUCT INCLUDES Hard case, FRB F connector, 9 V battery, set of (15) reflective strips, quick start guide and user manual. CA 1727 also includes a USB cable and TachoGraph software. CATALOG NO. 1748.10 1748.30 DESCRIPTION Tachometer Model CA 1725 Tachometer Model CA 1727 54 www.aemc.com Technical Assistance (800) 343-1391 © Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved. Vol. 23 Rev.00 02/2023 EELNEVCITRRIOCNALMTEESNTTTAOLOLTSESTERS DATA ANALYSIS AND REPORTING SOFTWARE SEE PAGE 133 FOR MORE INFO ON DATAVIEW® SOFTWARE CONFIGURE ENVIRONMENTAL TESTERS MODELS 1110, 1246, 1510, 1821, 1822 & 1823 Capture and display data in real-time / Configure all user selectable functions and parameters / Download and analyze stored data Create customizable reports / Print reports of all test results SEE WEBSVoIlT. 2E3 ReFv.0O0 02R/202P3 RICINGTeAchNnicaDl AsAsisVtaAncIeL(8A00)B34I3L-1I3T91Y: WWW.AEwMww.Caem.Cc.cOomM 55 © Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved. ENVIRONMENTAL TESTERS LIGHTMETER MODELS CA811 & CA813 Features optical sensors that are designed to match the response of the human eye SPECIFICATIONS MODELS CA811 CA813* MEASUREMENTS Range 20 fc, 200 fc, 2000 fc, 20 kfc 20 lx, 200 lx, 2000 lx, 20 klx 20 lx, 200 lx, 2000 lx, 20 klx, 200 klx Display Resolution 0.01 fc or 0.01 lx Sensor Silicon photodiode Spectral Response CIE Photopic Curve Accuracy 2856 K Light Source Common Light Source ± 5 % of Reading ± 10 cts ± 5 % of Reading ± 10 cts ± 18 % of Reading ± 2 cts ± 11 % of Reading ± 2 cts Sample Rate 2.5 times per s, nominal GENERAL Display Operating Temperature Storage Temperature Polarity Power Supply Low Battery Indication Dimensions Weight 3½ digit liquid crystal display (LCD), 2000-count (32 to 122) °F (0 to 50) °C, < 80 % RH (-4 to 140) °F (-20 to 60) °C, (0 to 80) % RH without battery Automatic (1) 9 V Alkaline battery (included) Displayed when battery voltage is low (6.81 x 2.38 x 1.5) in (173 x 60 x 38) mm Approx. 7.55 oz (214 g) including battery Approx. 7.9 oz (224 g) including battery Consult factory for NIST Calibration prices CA811 CA813 FEATURES · Easy one-hand operation · Designed to measure a wide range of lighting types · Removable sensor for remote reading · Measures in foot-candles (fc) or lux (lx) · Measures incandescent lighting · Cosine corrected · Hold function · Max function (CA811) · Peak function (CA813) · CIE photopic (human eye) response · 2000-count backlit LCD · Lightweight and compact · Removable protective sensor cover · Includes rugged, shockproof, protective and dirt resistant gray cover *Note: Model CA813 offers higher sensitivity (200 klx) and has a better spectral response to common light sources. Model CA811 is used to measure incandescent lighting. PRODUCT INCLUDES Rugged shockproof protective holster, 9 V battery and user manual. APPLICATIONS · Testing for OSHA compliance in workplace, cleanroom and industrial settings · Ambient testing for light-sensitive displays and archives in museums and art galleries CATALOG NO. 2121.20 2121.21 DESCRIPTION Lightmeter Model CA811 Lightmeter Model CA813 56 www.aemc.com Technical Assistance (800) 343-1391 © Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved. Vol. 23 Rev.00 02/2023 ENVIRONMENTAL TESTERS AIR QUALITY MODEL 1510 Monitor CO2, temperature, and humidity for a healthy environment Assists with the prevention of COVID 19 by testing indoor air quality. Contact us to learn more. SPECIFICATIONS MODEL 1510 CO2 MEASUREMENT Measuring Principle Non-dispersive infrared (NDIR) technology Type of Sensor Double-beam infrared cell sensor Measurement Range (0 to 5000) ppm Accuracy (CO2) ± 50 ppm ± 3 % of value measured Response Time (63 %) < 200 s Resolution 1 ppm TEMPERATURE MEASUREMENT Type of Sensor CMOS Units °C or °F Measurement Range (14 to 140) °F (-10 to 60) °C Accuracy ± 0.1 °F (± 0.5 °C) Resolution 0.1 °F (0.1 °C) HUMIDITY MEASUREMENT Type of Sensor Capacitive Measurement Range (5 to 95) % RH Accuracy ± 2 % RH Resolution GENERAL 0.1 % RH Recording Interval Storage Alarm Programmable from 1 min to 2 h > 1 million measurements Yes Backlighting Hold, Min & Max Blue - red when in alarm condition Yes Auto Power OFF Yes (in portable mode only) Dimensions / Weight Power Supply Communication (4.92 x 2.58 x 1.26) in (125 x 65 x 32) mm / 6.7 oz (190 g) with batteries Alkaline batteries: (2) AA or rechargeable battery connection to 120 V 60 Hz line / USB to wall adapter Bluetooth (Class I) wireless communication / USB link; the product is then recognized as a USB drive for easy file transfer Mounting DataView® Software Optional padlock wall mount (padlock is not included), optional desktop stand and wall mount holster Graphic representation or as table of values, data export, real-time mode calculation of the confinement index with selection of presence periods & report generation SAFETY Safety Rating Ingress Protection IEC 61010-1, 50 V CAT II IEC 61326-1 IP40 Consult factory for NIST Calibration prices CATALOG NO. DESCRIPTION CATALOG NO. 2138.08 Air Quality Logger Model 1510 (Gray) 2138.09 IP 40 FEATURES · CO2, temperature, and humidity logger · Free app for AndroidTM from the Google® Play Store · Display turns red when any of the measurements are in alarm condition · Compact and stand-alone: for mounting or portable use · User-friendly: comfort indicators based on the CO2, temperature and humidity levels · Accurate: complies with the latest standards concerning air quality monitoring · Quick, simple data download using supplied DataView® software · On-site calibration test module with adapter, tube and software for adjusting the zero and thresholds PRODUCT INCLUDES Soft carrying pouch, adapter - US wall plug to USB, 6 ft USB cable, (2) 1.5 V AA batteries, printed quick start guide, and a USB drive with DataView® software and user manual. ACCESSORIES/REPLACEMENTS Catalog #2138.61 Wall Mount Holster (Gray) Catalog #2153.78 Adapter - US Wall Plug to USB Catalog #2138.63 Calibration Kit Catalog #2138.66 6 ft USB cable Catalog #2117.73 Replacement Carrying Pouch DESCRIPTION Air Quality Logger Model 1510 (White) Vol. 23 Rev.00 02/2023 Technical Assistance (800) 343-1391 © Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved. www.aemc.com 57 ENVIRONMENTAL TESTERS SOUND LEVEL METER MODEL CA832 Designed to assess sound ambiences or nuisances in accordance with international safety and quality standards SPECIFICATIONS MODEL CA832 MEASUREMENTS Measurement Range Measurement Rate (37 to 80) dB (50 to 100) dB (80 to 130) dB 2.5 times per s Dynamic Range 50 db Frequency Range (31.5 to 8000) Hz Accuracy ± 1.5 dB (ref. 94 dB @ 1 kHz) Resolution 0.1 dB Precision ± 2.0 dB Display Sensor Type Applicable Standard Auxiliary Output Frequency Weighting 2000-count 0.5 in (13 mm) electric (pre-polarized) condenser microphone True RMS measurement with independent frequency weighting IEC 651 Type 2 / ANSI S 1.4 Type 2 / JIS C 1502 DC output: 10 mV/dB 50 AC output: 1.0 Vrms 600 Curves A and C Time Weighting S (slow) - 550 ms and F (fast) - 55 ms GENERAL Display 3½ digit liquid crystal display (LCD), 2000-count Operating Temperature (32 to 122) °F (0 to 50) °C, 80 % RH without condensation Storage Temperature (-4 to 140) °F (-20 to 60) °C, (0 to 80) % RH without battery Power Supply (1) 9 V Alkaline battery (included) Low Battery Indication is displayed when battery voltage is low Dimensions (9.33 x 2.38 x 1.5) in (237 x 60 x 38) mm Weight 8.11 oz (230 g) including battery Consult factory for NIST Calibration prices PRODUCT INCLUDES Shockproof holster, protective foam microphone cap, screwdriver, male jack connector, assembly screw for camera type tripod, 9 V battery and user manual. Tripod mounting screw allows for mounting on a standard tripod stand. (Tripod not included) CATALOG NO. 2121.23 DESCRIPTION Sound Level Meter Model CA832 IP 44 FEATURES · Easy one-hand operation · Measures sound according to the sensitivity of the human ear · Max function · Three measurement ranges from (37 to 130) dB · Accuracy ± 1.5 dB (ref. 94 dB @ 1 kHz) · Two time weighting curves: S (slow) - 550 ms and F (fast) 55 ms · Two frequency weighting curves: A and C · Auxiliary output for recording · Tripod mountable · 2000-count backlit LCD · Lightweight and compact · Includes rugged, shockproof, protective and dirt resistant gray cover APPLICATIONS · Factories · Schools and libraries · Airports · Office environments and studios · Auditoriums · Hospitals · Art Galleries 58 www.aemc.com Technical Assistance (800) 343-1391 © Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved. Vol. 23 Rev.00 02/2023 ENVIRONMENTAL TESTERS THERMO-HYGROMETER MODEL 1246 Measure humidity and temperature in all conditions SPECIFICATIONS MODEL 1246 RELATIVE HUMIDITY Measurement Range (3.0 to 98.0) % RH Accuracy (10 to 90) % RH: ± (2 % RH ± 1 ct), outside that range: ± (4 % RH ± 1 ct) Resolution 0.1 % RH Response Time (66 %) 60 s TEMPERATURE Type of Sensor Temperature sensor with semiconductor Measurement Range (-10.0 to + 60.0) °C; (14.0 to + 140.0) °F Resolution Display in °C: 0.1 °C; Display in °F: 0.1 °F Accuracy (°C) (10 to 40) °C: ± (0.5 °C ± 1 ct) Outside that range: ± (0.032 x (T-25) ± 1 ct) / T= temperature in °C Response Time (66 %) 30 s DEW POINT Measurement Range (-10.0 to + 60.0) °Ctd; (14.0 to + 140.0) °Ftd Resolution Display in °C: 0.1 °C; Display in °F: 0.1 °F FUNCTIONS Recording Manual Start/Stop Short press for MEM: spot recording Long press for REC: recording at the user selectable rate Programmed recording rates from 1 min to 2 h Start date and end date can be customized with the PC software Alarms Alarm thresholds settable in the software Recording can be triggered on an alarm threshold Data storage More than 1 million measurements Min-Max Real-time display of Min and Max readings available at the press of a button Hold Freezes the measurement value on the display Units °C or °F / % RH Automatic power-off User selectable choice of 3 min, 5 min, 10 min, or OFF through DataView® software POWER SUPPLY Type (3) 1.5 V AA / LR6 alkaline batteries. Connection to line power using supplied micro-USB cable. Wall adapter sold separately Battery Life 1,000 h (portable mode) 3 y of recording (15-minute measurement interval) GENERAL Interfaces Mounting 2 Communication modes: Bluetooth wireless link and USB Case equipped with a magnet for mounting to a metal surface and a tear drop for wall mounting. Compatible with the Multifix accessory (cat. #5000.44) Dimensions / Weight (7.36 x 2.84 x 1.28) in (187 x 72 x 32) mm / 14.1 oz (400 g) with batteries Operating Range Temperature: (14 to 140) °F (-10 to +60) °C / Humidity: (10 to 90) % RH DataView® software Display as a graph or table of values; Data export in graph/MS Excel table; Functions Real-time mode; Automatic standard or custom report generation SAFETY/WARRANTY Safety Rating IEC61010-1 / IEC 61326-1 Ingress Protection IP54 Warranty 2 y Consult factory for NIST Calibration prices CATALOG NO. DESCRIPTION 2121.73 Thermo-Hygrometer Data Logger Model 1246 IP 54 FEATURES · Measures temperature, humidity and dew point · Dual line display toggles between any two of the measurements · User selectable temperature units (°F or °C) · Built in sensor with removable protective cap · Min, and Max measurements stored · Hold function freezes the display · Spot or continuous recording up to 1 million measurements · Blue luminescent backlit display · Programmable alarms for temperature and humidity through included software · USB and Bluetooth communication · Magnetic mount · Battery or USB powered · DataView® graphing and analysis software PRODUCT INCLUDES Soft carrying case, 6 ft USB cable (Type A to Type B USB), (3) 1.5 V AA alkaline batteries, printed quick start guide, and a USB drive with DataView® software and user manual. ACCESSORIES Catalog #2118.09 General Purpose Carrying Case Catalog #2118.65 Soft Carrying Case Catalog #2122.31 Shockproof Housing Catalog #2138.66 6 ft USB cable Catalog #2153.78 Adapter - US Wall Plug to USB Catalog #5000.44 MultiFix Universal Mounting System Vol. 23 Rev.00 02/2023 Technical Assistance (800) 343-1391 © Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved. www.aemc.com 59 ENVIRONMENTAL TESTERS THERMO-HYGROMETER MODEL CA846 Provides excellent response time to changes in temperature, good repeatability and accurate readings SPECIFICATIONS MODEL CA846 MEASUREMENTS -- TEMPERATURE Measurement Range (-4 to 140) °F (-20 to 60) °C Display Resolution 0.1 °F (0.1 °C) Sensor NTC Temperature Sensor Accuracy (-4 to 32) °F: ± 2 °F (-20 °C to 0 °C: ± 1 °C) (32 to 140) °F: ± 1 °F (0 °C to 60 °C: ± 0.5 °C) MEASUREMENTS -- RELATIVE HUMIDITY Measurement Range (0 to 100) % RH Display Resolution 0.1 % RH Sensor Capacitive Humidity Sensor Accuracy ± 5.0 %, 25 °C, (10 to 90) % RH ± 10.0 %, 25 °C, (0 to 10) % RH, (90 to 100) % RH GENERAL Display 3½ digit liquid crystal display (LCD), 2000-count Operating Temperature (32 to 122) °F (0 to 50) °C, 80 % RH Storage Temperature (-4 to 140) °F (-20 to 60) °C, (0 to 80) % RH without battery Polarity Automatic Power Supply (1) 9 V Alkaline battery (included) Low Battery Indication is displayed when battery voltage is low Dimensions (6.81 x 2.38 x 1.5) in (173 x 60 x 38) mm Weight Approx. 7 oz (198 g) including battery FEATURES · Easy one-hand operation · Measures temperature in °F and °C · Accurate NTC sensor · Quick response RH sensor · MAX and HOLD functions · 2000-count backlit LCD · Lightweight and compact · Removable protective sensor cover · Includes rugged, shockproof, protective and dirt resistant gray cover PRODUCT INCLUDES Shockproof holster, 9 V battery and user manual. APPLICATIONS · Greenhouses · HVAC installation and maintenance · Office environments · Labs · Environmental studies · Weather monitoring · Food distribution and storage · Blood banks CATALOG NO. 2121.24 DESCRIPTION Thermo-Hygrometer Model CA846 (NTC) 60 www.aemc.com Technical Assistance (800) 343-1391 © Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved. Vol. 23 Rev.00 02/2023 ENVIRONMENTAL TESTERS TEMPERATURE MODEL 1822 Versatility & high performance temperature measurement 1822 IP 50 with USB connector closed PRODUCT INCLUDES Soft carrying case, 6 ft USB cable (Type A to Type B USB), (2) K Thermocouple flexible sensors, (3) 1.5 V AA alkaline batteries, printed quick start guide, and a USB drive with DataView® software and user manual. ACCESSORIES/REPLACEMENTS Catalog #2117.73 Carrying Pouch Catalog #2138.66 6 ft USB cable Catalog #5000.44 MultiFlex Universal Mounting System Catalog #2153.78 Adapter US Wall Plug to USB Catalog #2122.31 Shockproof Housing FEATURES · Selectable Thermocouple type, J, K, T, N, E, R, S · Single and dual channel · Dual line display · User selectable temperature units, °F, °C · Min and Max measurements stored · HOLD function freezes the display · Spot or continuous recording up to 1 million measurements · Blue luminescent backlit display · Programmable store on alarm function · Magnetic mount · Programmable alarms through software · DataView® graphing and analysis software included · Battery or USB powered · Free app for AndroidTM from the Google® Play Store CATALOG NO. 2121.75 DESCRIPTION Thermocouple Thermometer Data Logger Model 1822 Vol. 23 Rev.00 02/2023 Technical Assistance (800) 343-1391 © Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved. www.aemc.com 61 ENVIRONMENTAL TESTERS TEMPERATURE DATA LOGGER MODEL 1822 1822 Thermocouple Thermometer MEASUREMENTS Measurement Range Resolution Accuracy (°C) J, K, T, N, E: R, S: FUNCTIONS Recording Alarms Data Storage J, K, T, N, E, R, S: 2 Channel J: (210 to + 1,200) °C / (-346 to + 2,192) °F K: (200 to + 1,372) °C / (-328 to + 2,501) °F T: (250 to + 400) °C / (-418 to + 752) °F N: (200 to + 1,300) °C / (-328 to + 2,372) °F E: (150 to + 950) °C / (-238 to + 1,742) °F R,S: (0 to + 1,767) °C / (32 to + 3,212) °F Display in °C: ø < 1,000 °C : 0.1 °C and ø 1,000 °C : 1 °C Display in °F: ø < 1,000 °F : 0.1 °F and ø 1,000 °F : 1 °F ø - 100 °C ± (0.2 % Reading + 0.6 °C) - 100 °C < ø + 100 °C ± (0.15 % R + 0.6 °C) + 100 °C < ø ± (0.1 % R + 0.6 °C) ø + 100 °C ± (0.15 % R + 1.0 °C) + 100 °C < ø ± (0.1 % R + 1.0 °C) Manual Start/Stop Short press on MEM: spot recording Long press on REC: recording at the user selectable rate Programmed recording rates from 1 min to 2 h Start date and end date can be customized with the PC software Alarm thresholds set using the software. Visual alert on the product in the event of an overrun. Recording can be triggered on alarm thresholds. More than 1 million measurements Min-Max Real-time display of Min and Max readings available at the press of a button. Hold Freezes the measurement value on the display. Differential Measurement Yes Units °C or °F Backlighting Blue luminescent Automatic Power Off MECHANICAL Interfaces User selectable choice of 3, 5 or 10 min, or off through DataView® software. 2 communication modes: Bluetooth and USB Mounting Case equipped with a magnet, a wall mount system and a slot for suspension of the product. Compatible with the MultiFix accessory (Cat. #5000.44). Shockproof housing available as an accessory (Cat. #2122.31). Connections Compensated miniature female connectors Dimensions/Weight (5.9 x 2.84 x 1.28) in (150 x 72 x 33) mm / 9.2 oz (260 g) with batteries Operating Range POWER SOURCE Type Battery Life SAFETY Safety Rating Ingress Protection GENERAL DataView® Software Functions Temperature from (14 to 140) °F (-10 to +60) °C / Humidity from (10 to 90) % RH (3) 1.5 V AA / LR6 alkaline batteries Connection to line power using supplied micro-USB cable. Wall adapter sold separately Model 1821 & 1822: 1,000 h (portable mode) Model 1823 : 800 h (portable mode) 3 y for recording (15-minute measurement interval) IEC61010-1 / IEC 61326-1 IP50 with the USB connector closed, per IEC 60 529 Real-time mode; Automatic report generation in Microsoft Word format Graph or value-table presentation; Data export in graph or Microsoft Excel table format Warranty 2 y 62 www.aemc.com Technical Assistance (800) 343-1391 © Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved. Vol. 23 Rev.00 02/2023 ENVIRONMENTAL TESTERS LIGHTMETER MODEL 1110 Features optical sensors that are designed to match the response of the human eye SPECIFICATIONS MODEL 1110 Measurement Range (0.01 to 200,000) lx (0.01 to 18,580) fc Accuracy ± 3 % of R on incandescent sources ± 6 % of R on LEDs (3,000 to 6,000) K ± 9 % of R on fluorescent sources Accuracy with Compensation LED mode: ± 4 % of R (at 4,000 K) Flou mode: ± 4 % of R (type F11, 4,000 K) Display Resolution 0.1 lx (0.1 to 999.9) lx 1 lx (1,000 to 9,999) lx 10 lx (10,000 lx to 99.99 klx) 100 lx beyond 0.01 fc (0.01 to 99.99) fc 0.1 fc (100.0 to 999.9) fc 1 fc (1,000 to 9,999) fc 10 fc beyond Recording Manual start/stop on the product Short press for MEM: spot recording Long press for REC at the defined default rate Programed recording: start date, recording interval, and end date defined using DataView® software Other Functions MIN-AVG-MAX-HOLD Sampling Rate Programmable from 1, 2, 5, 10, 20, or 30 s, 2, 5, 10, 15 or 30 min, and 1 hr MAP mode The MAP mode can be used to map the lighting on the surface of a room. In this case the measurements are saved in the same file. Operating Temperature (14 to 140) °F (-10 to 60) °C Storage Temperature (-4 to 140) °F (-20 to 60) °C Relative Humidity Up to 90 % RH GENERAL Memory 1,000,000 measurements on each channel (4 MB). Recorded data is stored in non-volatile memory and will be retained even if battery is low or removed. Communication USB 2.0 and Bluetooth Power Supply (3) 1.5 V AA (LR6) alkaline batteries or USB port (micro-USB adaptor offered as an accessory) Battery Life 500 h, 3 yrs with 15 min intervals Dimensions Case: (5.9 x 2.84 x 1.28) in (150 x 72 x 33) mm Sensor: (2.64 x 2.52 x 1.38) in (67 x 64 x 35) mm Weight (with battery) 12.2 oz (34 g) with batteries Case Polycarbonate SAFETY EMC EN 61326-1 Safety Rating IEC 61010-1 Ingress Protection IP50 with USB connector closed and protective cap on sensor Warranty 2 y Consult factory for NIST Calibration prices CATALOG NO. 2121.71 DESCRIPTION Lightmeter Data Logger Model 1110 IP 50 FEATURES · User selectable light source, natural, LED or fluorescent · Spectral error compensation for LED and fluorescent lighting · Removable light sensor with expandable cable up to 48 inches · Map mode profiles the illuminance map of the area or room by storing multiple measurements · Min, Max, and Average measurements stored · Free app for AndroidTM from the Google® Play Store · Spot or continuous recording of up to 1,000,000 measurements stored in 8 MB flash memory · Blue luminescent backlit display · User selectable foot-candle (fc) or lux (lx) units · USB and Bluetooth communication · Magnetic mount · Battery or USB powered · DataView® graphing and analysis software included Measure and record multiple measurements to create an illuminance map of the room or area of interest PRODUCT INCLUDES Soft carrying pouch, 6 ft USB cable, (3) 1.5 V AA batteries, a printed quick start guide, USB drive with DataView® software and user manual. ACCESSORIES/ REPLACEMENTS Catalog #2118.65 Soft Carrying Case Catalog #2138.66 6 ft USB cable Catalog #2118.09 General Purpose Carrying Case Catalog #2122.31 Shockproof Housing Catalog #2153.78 Adapter - US Wall Plug to USB Catalog #5000.44 MultiFix Universal Mounting System Vol. 23 Rev.00 02/2023 Technical Assistance (800) 343-1391 © Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved. www.aemc.com 63 AEMC® Instruments is a global leader in Power/Energy Quality Analyzers, Meters and Loggers, Current Probes, Ground Resistance Testers and Insulation Testers. We are the brand you can trust! GROUND RESISTANCE TESTERS DATA ANALYSIS AND REPORTING SOFTWARE SEE PAGE 133 FOR MORE INFO ON DATAVIEW® SOFTWARE CONFIGURE GROUND RESISTANCE TESTERS MODELS 6417, 6471 & 6472 Run tests and analyze real-time data from your PC / Configure all test functions and parameters from your PC / Customize views, templates and reports / Display Fall-of-Potential plots, tabular listing of test results and more / Print reports of all test results SEE WEBSITE FOR PRICING AND AVAILABILITY: WWW.AEMC.COM GROUND RESISTANCE TESTERS MULTI-FUNCTION MODELS 6422 & 6424 To keep your installation safe, measure the resistance of its connection to earth SPECIFICATIONS MODELS ELECTRICAL Voltage Measurement Range Resolution Accuracy Current Range Ground Resistance (2P Mode) Measurement Range Resolution Accuracy Ground Resistance (3P Mode) 6422 IP 65 6424 (0.1 to 600) VAC/DC 0.1 V ± (1 % R + 1 ct) (0.5 to 60.00) AAC (requires optional MN72 probe) (0.05 to 99.99) , (80.0 to 999.9) , (0.80 to 9.999) k, (8.00 to 50.00) k 0.01 , 0.1 , 1 , 10 ± (2 % R + 10 ct), ± (2 % R + 2 ct), ± (2 % R + 1 ct), ± (2 % R + 1 ct) Measurement Range (0.50 to 99.99) (80.0 to 999.9) (0.800 to 2.000) k (0.50 to 99.99) (80.0 to 999.9) (0.800 to 9.999) k (8.00 to 50.00) k Resolution 0.01 0.1 1 0.01 0.1 1 10 Accuracy ± (1 % R + 10 ct) ± (1 % R + 2 ct) ± (1 % R + 1 ct) ± (1 % R + 10 ct) ± (1 % R + 2 ct) ± (1 % R + 1 ct) Measurement Frequency (128 or 256) Hz (automatically selected) No-load Voltage Maximum Test Current ± 10 V peak 20 mA Measurement Mode Data Storage One shot or continuous Stores the (52, 62 and 72) % 3P resistance measurements Calculation GENERAL Calculates average and % deviation of the three saved readings Display Measurement Mode 2P (), 3P () Backlit LCD V, I, 2P (), 3P () Power Supply Battery Life (6) AA alkaline batteries > 2,000 x 3P earth measurements at 100 (6) NiMH rechargeable batteries, charging time approx. 6 h > 1,500 x 3P earth measurements at 100 Dimensions SAFETY (8.78 x 4.96 x 2.75) in (223 x 126 x 70) mm Safety Rating EMC: IEC 61326-1; IEC 61010-2-030 / 600 V CAT IV Consult factory for NIST Calibration prices CATALOG NO. 2135.55 2135.56 2135.57 2135.58 2135.59 DESCRIPTION Ground Resistance Tester Model 6422 (Digital, 3-Point) Ground Resistance Tester Model 6422 Kit-150 ft (Digital, 3-Point) Ground Resistance Tester Model 6424 (Digital, 3-Point) Ground Resistance Tester Model 6424 Kit-150 ft (Digital, 3-Point) Ground Resistance Tester Model 6424 Kit-300 ft (Digital, 3-Point) 66 www.aemc.com Technical Assistance (800) 343-1391 © Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved. Vol. 23 Rev.00 02/2023 GROUND RESISTANCE TESTERS MULTI-FUNCTION MODELS 6422 & 6424 FEATURES · Simple, one button operation - eliminates errors in testing · Test button turns green when measurement is stable · 2 P resistance measurement up to 50 k · 3 P ground resistance measurement up to 2 k (Model 6422) up to 50 k (Model 6424) for highly resistive terrain · Large back lit digital display easier to read in all lighting conditions · Automatic hold function - retains last measurement after the reading stabilizes ensuring the measurement is valid · Automatic test frequency selection between 128 Hz and 256 Hz, providing stable results in adverse environments · Powers up in 2 pole mode automatically checks the injector lead connection when connected to the H auxiliary rod · Convenient storage of the three measurements along with the average and % deviation - easily determines proper test results · Built in test lead compensation capability improves the accuracy of low resistance measurements · CAT IV 600 V rated for a high level of operator safety · Checks AC/DC voltage (Model 6424) · Stores (52, 62 and 72) % measurements eliminates errors in determining the ground resistance (Model 6424) · Leakage current measurement from 0.5 mA to 60 A (Model 6424) · Battery recharging via AC adapter, USB or vehicle DC port (Model 6424) · Color coded leads and terminals provide fast, error-free connection · Detects the presence of hazardous voltage and prohibits measurement · Direct access to all functions, even when wearing work gloves · Rugged water resistance case, for all terrain use · Built-in display stand to prop up instrument for seeing the display better when placed on the ground ACCESSORIES/REPLACEMENTS Catalog #2135.39 Ground Rod Set of (2) 14.5 in T-shaped Auxiliary Rods Catalog #2153.06 MN72 AC Current Probe (6424 only) CATALOG #5000.92 Calibration Checker CATALOG #5000.92 FUNCTIONAL DISPLAYS 2 P mode used for continuity and bonding checks is active when the instrument is turned on Model 6424 3 P mode used for measuring the grounding system. The resistance of the injector electrode and the test voltage are also displayed Live voltage is displayed when the V/A function is selected and test leads are connected to AC or DC voltage (Model 6424) Leakage current is displayed when the optional MN72 probe is connected and the V/A function is selected (Model 6424) FRONT PANEL - 6424 PRODUCT INCLUDES Models 6422 and 6424: (2) 150 ft color-coded leads on spools (red/blue), (1) 30 ft lead (green), (2) T-shaped auxiliary ground electrodes, set of (2) 5 ft colorcoded (red/blue) leads, (1) 100 ft tape measure, (6) AA rechargeable NiMH batteries, carrying bag and user manual Model 6424 also includes: USB to wall charger, 5 V, 2 A, USB charger cable CATALOG #2153.06 KITS AVAILABLE SHOWN: CATALOG #2135.35 Vol. 23 Rev.00 02/2023 Technical Assistance (800) 343-1391 © Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved. www.aemc.com 67 GROUND RESISTANCE TESTERS DIGITAL TESTERS MODELS 4620 & 4630 Both models will perform over 2000 measurements for the 15 second tests between recharging or battery replacement SPECIFICATIONS MODELS ELECTRICAL Range Measurement Range Resolution Open Voltage Measurement Frequency Test Current Accuracy 4620 4630 20 200 2000 (0.00 to 19.99) (20.0 to 199.9) (200 to 1999) 10 m 100 m 1 42 V peak 128 Hz square wave 10 mA 1 mA 0.1 mA ± 2 % of Reading ± 1 ct ± 5 % of Reading ± 3 cts Aux Electrode Influence Max Res. - Current Circuit 3 k Max Res. - Voltage Circuit 30 k 50 k 50 k Response Time Withstanding Voltage Power Supply Battery Life Fuse Protection Approximately four to eight seconds for a stabilized measurement 250 VAC or 100 VDC (8) C cell batteries (120/230) V, (50/60) Hz (included); Rechargeable 9.6 V, 3.5 A·h Alkaline recommended NiMH battery pack (included) > 2000 15-second measurements; LO BAT indication on LCD 0.1 A, > 250 V , (0.25 x 1.25) in; 30 kA Interrupt Capacity Consult factory for NIST Calibration prices ACCESSORIES/REPLACEMENTS Catalog #2130.60 Tape Measure (100 ft) Catalog #2135.35* Test Kit for 3-Point Testing 150 ft Catalog #2135.36* Test Kit for 4-Point Testing 300 ft Catalog #2135.37* Test Kit for 4-Point Testing 500 ft Catalog #2135.38 Ground Test Kit for 3-Point Testing (Supplemental for 4-Point testing includes (2) 100 ft color-coded leads, (1) 30 ft lead (green), (2) 14.5 in T-shaped auxiliary ground electrodes and soft carrying bag) Catalog #2130.59 Calibration Checker 25 for Models 3640, 4500, 4610, 4620 and 4630 Catalog #5000.14 AC Power cord (4630) KIT SHOWN 4630 KIT (500 ft) 4620 4630 IP IP 65 53 cover closed cover open FEATURES · Ground Integrity Measurement · Measures soil resistivity (4-Point) · Measures ground resistance (2- and 3-Point) Fall-of-Potential method · Step voltage tests and touch potential measurements · Auto-Ranging: automatically selects the optimum resistance range and test current · Designed to reject high levels of noise and interference · Extremely simple to operate: connect/press/hold/read · LED on faceplate informs operator of high input noise, high auxiliary rod resistance and faulty connections · Large easy-to-read backlit display · Battery powered (Model 4620) · AC powered with rechargeable NiMH battery pack (Model 4630) · Rugged dustproof and watertight field case · Color-coded terminals PRODUCT INCLUDES (8) C-cell batteries (4620) or rechargeable 9.6 V NiMH battery pack (4630), AC power cord (4630), and user manual. *Refer to page 75 for Test Kit descriptions CATALOG NO. 2130.43 2130.44 2135.19 2135.20 2135.21 2135.22 2135.23 2135.24 DESCRIPTION Ground Resistance Tester Model 4620 (Digital, 4-Point, Battery Powered) Ground Resistance Tester Model 4630 (Digital, 4-Point, Rechargeable Battery) Ground Resistance Tester Model 4620 Kit 150 ft (Model 4620 and Catalog #2135.35) Ground Resistance Tester Model 4620 Kit 300 ft (Model 4620 and Catalog #2135.36) Ground Resistance Tester Model 4620 Kit 500 ft (Model 4620 and Catalog #2135.37) Ground Resistance Tester Model 4630 Kit 150 ft (Model 4630 and Catalog #2135.35) Ground Resistance Tester Model 4630 Kit 300 ft (Model 4630 and Catalog #2135.36) Ground Resistance Tester Model 4630 Kit 500 ft (Model 4630 and Catalog #2135.37) 68 www.aemc.com Technical Assistance (800) 343-1391 © Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved. Vol. 23 Rev.00 02/2023 GROUND RESISTANCE TESTERS CLAMP-ON MODELS 6416 & 6417 Provides high safety level with new ground voltage indication feature SPECIFICATIONS MODELS 6416 & 6417 ELECTRICAL Ground Resistance Measurement Range (0.010 to 0.099) (0.10 to 0.99) Resolution 0.001 0.01 Accuracy (% of Reading) ± 1.5 % ± 0.01 ± 1.5 % ± 0.02 Auto-Ranging (0.01 to 1499) (1.0 to 49.9) (50.0 to 99.5) (100 to 199) 0.1 0.5 1 ± 1.5 % ± 0.1 ± 2 % ± 0.5 ± 3 % ± 1 (200 to 395) 5 ± 5 % ± 5 (400 to 590) 10 ± 10 % ± 10 (600 to 1150) 50 20 % approx (1200 to 1500) 50 25 % approx Current Measurement (0.200 to 0.999) mA (1.000 to 2.990) mA (3.00 to 9.99) mA 1 µA 10 µA ± 2 % ± 50 µA Auto-Ranging 1 mA to 40 A (10.00 to 29.90) mA (30.0 to 99.9) mA 100 µA ± 2 % ± 100 µA (100.0 to 299.0) mA (0.300 to 0.990) A 1 mA ± 2 % ± 1 mA (1.000 to 2.990) A (3.00 to 39.99) A 10 mA ± 2 % ± 10 mA Selectable Measurement Frequency (50, 60, 128 or 2083) Hz Current Measurement Frequency (47 to 800) Hz Inductance Measurement (10 to 100) µH; (100 to 500) µH Current Overload OL displayed above 39.99 Arms Communication Power Supply SAFETY Bluetooth connection (Model 6417 only) (4) 1.5 V LR6 (AA) alkaline batteries or (4) NiMH batteries; Battery life: 12 h, or 1440, 30 - s measurements approx. Safety Rating EN 61010-1, 600 V CAT IV Consult factory for NIST Calibration prices PRODUCT INCLUDES 6416 & 6417 Hard carrying case, wrist strap calibration loop, (4) 1.5 V AA batteries and user manual. 6417 Also includes Bluetooth USB adapter, printed quick start guide, a USB drive with DataView® software, ground tester workbook and user manual. 6416 6417 ** * IP 40 FEATURES *6417 only · Ground Integrity Measurement · Ground voltage indication (warns of possible unsafe conditions) · Large multi-function bright yellow OLED (organic LED display) · Selectable test frequency (improves accuracy in inductive environments) · Clamping diameter of 1.37 in (35 mm) with large jaw design · Storage of measurements ( and/or A, with time-stamping) · Model 6416: up to 300 measurements stored · Model 6417: up to 2000 measurements stored · View stored measurements on the OLED display or via Bluetooth (Class 2 - communicates up to 30 ft) to a PC or the AndroidTM based mobile application (Model 6417) · Auto Power OFF function · Alarm function with adjustable set point and buzzer for quick field checks for volts, amps and ohms · Rugged Lexan® head and body construction resists breakage · Alarm settings and stored memory information saved during shutdown · Includes DataView® software for data retrieval, real-time display, analysis, report generation and system configuration (Model 6417) · Noise icon and buzzer alert user to presence of dangerous voltage and current levels CATALOG NO. 2141.01 2141.02 DESCRIPTION Ground Resistance Tester Model 6416 (Clamp-On, Alarm, Memory) Ground Resistance Tester Model 6417 (Clamp-On, Bluetooth, Alarm, Memory, DataView® Software) Vol. 23 Rev.00 02/2023 Technical Assistance (800) 343-1391 © Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved. www.aemc.com 69 GROUND RESISTANCE TESTERS CLAMP-ON MODEL 6418 Designed for measuring ground impedance on ground rods and bus bars SPECIFICATIONS MODEL ELECTRICAL 6418 Measurement Range Resolution Accuracy (% of Reading) (0.010 to 0.099) 0.001 ± 1.5 % ± 0.01 (0.10 to 0.99) 0.01 ± 1.5 % ± 0.02 Ground Resistance (1.0 to 49.9) (50.0 to 149) 0.1 ± 1.5 % ± 0.2 1 ± 2.5 % ± 2 Auto Ranging (150 to 245) (250 to 440) 5 ± 5 % ± 10 10 ± 10 % ± 20 Measurement Frequency Current Measurement (450 to 640) 10 (650 to 1200) 50 2083 Hz (0.50 to 9.950) mA 50 µA (10.00 to 99.90) mA 100 µA ± 15 % ± 20 ± 20 % Reading + 100 ± 2 % + 200 µA ± 2 % + 100 µA Auto Ranging 1 mA to 20 A (100.0 to 299.0) mA 1 mA ± 2 % ± 1 mA (0.300 to 2.990) A 10 mA ± 2 % ± 10 mA Current Measurement Frequency Current Overload Power Supply (3.000 to 20.00) A 100 mA ± 2 % ± 100 mA (47 to 800) Hz OL displayed above 19.99 Arms (4) 1.5 V LR6 (AA) alkaline batteries or (4) NiMH batteries; Battery life: 12 h, or 1440 30 s Measurements approx. Consult factory for NIST Calibration prices PRODUCT INCLUDES Hard carrying case, 5 « calibration loop, (4) 1.5 V AA batteries, wrist strap and a user manual. SAFETY IP R ATIN G 40 CLAMPING CHARACTERISTICS 30 20 Ø32 40 55 FEATURES · Ground Integrity Measurement · Large multi-function bright yellow OLED (organic LED display) (1.89 x 1.55) in (48 x 39) mm · Clamping diameter accommodates both cable and bus bar · Storage of measurements ( and/or A, with time-stamping) · Up to 300 measurements stored · View stored measurements on the OLED display · Auto Power OFF function · Auto Hold · Alarm function with adjustable set point and buzzer for quick field checks for amps and ohms · Rugged Lexan® head and body construction resists breakage · Alarm settings and stored memory information saved during shutdown · Noise icon and buzzer alert user to presence of dangerous current levels · Designed to EN 61010-1, 100 V CAT IV and 150 V CAT III safety standards · Automatic calibration of the jaw gap at power-up CATALOG NO. 2141.03 DESCRIPTION Ground Resistance Tester Model 6418 (Clamp-On, Alarm, Memory, Oblong Jaws) 70 www.aemc.com Technical Assistance (800) 343-1391 © Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved. Vol. 23 Rev.00 02/2023 GROUND RESISTANCE TESTERS CLAMP-ON FUNCTIONAL DISPLAYS Disturbance indicator (current) in the loop HOLD Function active Buzzer is displayed when active Measurement date/time display Advanced Mode selection Indicates when the inductive component is negligible in Advanced Mode Main measurement display Measurement unit display Data Storage Mode Memory Recall Mode Memory index number display Bluetooth connection indicator (6417 only) MEASUREMENT RESULTS Note: Display shown larger than actual size MEMORY RECALL MODE Incorrect jaw closing indicator Auto Power OFF active Battery charge indicator 4000-count upper measurement display Upper display measurement unit Main display measurement unit Hazardous voltage indicator (not available on 6418) Alarm measurement display unit Alarm threshold display Alarm active indicator ALARM Displays the leakage current and loop impedance at the test frequency LOOP DETECTION Measurement storage date-time screen GROUND VOLTAGE Indicates voltage/current alarm threshold along with the direction of impedance IMPEDANCE OVER RANGE Detects and displays possible false readings associated with metal loops Indicates voltage potential at the point of measurement Indicates that the impedance is greater than 1500 Vol. 23 Rev.00 02/2023 Technical Assistance (800) 343-1391 © Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved. www.aemc.com 71 GROUND RESISTANCE TESTERS MULTI-FUNCTION MODEL 6471 Test ground resistance without the need of auxiliary rods or with the 3- and 4- Point methods SPECIFICATIONS MODEL 6471 ELECTRICAL 2-Clamp Measurement Range (0.10 to 500) Resolution (0.01 to 1) Measurement Frequency Auto: 1611 Hz Manual: (128, 1367, 1611, or 1758) Hz 3-Point Measurement Range (Auto-Ranging) 0.09 to 99.9 k Resolution (0.01 to 100) Test Voltage Nominal (16 or 32) Vrms user selectable Resistance Measurement Frequency (41 to 513) Hz automatic or user selectable Test Current Up to 250 mA Accuracy ± 2 % of Reading + 1 ct @ 128 Hz Soil Resistivity 4-Point Measurement Test Method Wenner or Schlumberger selectable with automatic calculation in -meters Range (Auto-Ranging) (0.01 to 99.9) k; Ã max: 999 km Resolution (0.01 to 100) Test Voltage (16 or 32) V user selectable Frequency From (41 to 128) Hz selectable External Voltage Measurement Range (Auto-Ranging) (0.1 to 65.0) VAC/DC DC to 440 Hz Accuracy ± 2 % of Reading + 1 ct Resistance Measurement (Bond Testing) Measurement Type 2-Pole (with lead resistance compensation) or 4-Pole (Kelvin sensing) user selectable Range (Auto-Ranging) 2-Pole (0.12 to 99.99) k; 4-Pole (0.02 to 99.99) k Accuracy ± 2 % of Reading + 2 cts Test Voltage 16 VDC (+, - or auto polarity) Test Current Up to 250 mA max Data Storage Memory Capacity 512 test results (64 kB) Communication Optically Isolated USB Power Supply 9.6 V rechargeable battery pack (included) Recharging Source 110 V/220 V, (50/60) Hz external charger with 18 VDC, 1.9 A output Consult factory for NIST Calibration prices ACCESSORIES MN82 CURRENT PROBE SR182 CURRENT PROBE REEL CADDY (2 mA to 10 Arms) (0.5 mA to 40 Arms) Catalog #2135.85 Set of (2), Catalog #2135.71 Catalog #2135.72 for use with ground kit spools IP 53 cover closed GROUND RESISTANCE MEASUREMENT USING 2 PROBES For systems with parallel ground connections, Models 6471 and 6472 are capable of accurately measuring a ground resistance using probes only. This method involves placing 2 probes around the ground conductor to be tested and connecting them each to the instrument. One probe injects a known signal (32 V/1367 Hz) while the other probe measures the current circulating in the loop. This method saves considerable time when ground testing because it is no longer necessary to set up auxiliary rods or to disconnect the ground connector. PRODUCT INCLUDES CAT. #2135.48 MODEL 6471 (without probes) Meter, carrying bag, 110 V/240 V power adapter with US power cord, optical USB cable, rechargeable NiMH battery, and a USB drive with DataView® software, ground tester workbook and user manual. CAT. #2135.49 MODEL 6471 (with probes) Meter, carrying bag, set of (2) SR182 current probes, 110 V/240 V power adapter with US power cord, optical USB cable, rechargeable NiMH battery, and a USB drive with DataView® software, ground tester workbook and user manual. KIT SHOWN 300 FT KIT: CATALOG #2135.50 Meter, carrying bag for kit, (2) 300 ft color-coded (red/blue) leads on spools, (2) 5 ft color-coded (red/blue) leads, (2) 100 ft hand-tied color-coded (green/black) leads, set of (2) SR182 current probes, 110 V/240 V power adapter with US power cord, optical USB cable, (4) T-shaped auxiliary ground electrodes, set of (5) spaded lugs, 100 ft tape measure, rechargeable NiMH battery, and a USB drive with DataView® software, ground tester workbook and user manual. 2 probes required to perform stakeless testing 72 www.aemc.com Technical Assistance (800) 343-1391 © Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved. Vol. 23 Rev.00 02/2023 GROUND RESISTANCE TESTERS MULTI-FUNCTION MODEL 6472 Use under difficult conditions such as the presence of high stray currents that normally affect accuracy SPECIFICATIONS MODEL 6472 ELECTRICAL 2-Clamp Measurement Range (0.1 to 500) Resolution (0.01 to 1) Measurement Frequency Auto: 1611 Hz Manual: (128, 1367, 1611, or 1758) Hz 3-Point Measurement Range (Auto-Ranging) 0.09 to 99.9 k Resolution (0.01 to 100) Test Voltage Nominal (10, 16, 32 or 60) Vrms user selectable Resistance Measurement Frequency (41 to 5078) Hz automatic or user selectable Test Current Up to 250 mA Accuracy ± 2 % of Reading + 1 ct @ 128 Hz Soil Resistivity 4-Point Measurement Test Method Wenner or Schlumberger selectable with automatic calculation of test results in -meters Range (Auto-Ranging) (0.01 to 99.9) k; Ã max: 999 km Resolution (0.01 to 100) Test Voltage (16 or 32) V user selectable Frequency From (41 to 128) Hz selectable External Voltage Measurement Range (Auto-Ranging) (0.1 to 65.0) VAC/DC DC to 440 Hz Accuracy ± 2 % of Reading + 1 ct Resistance Measurement (Bond Testing) Measurement Type Range (Auto-Ranging) 2-Pole (with lead resistance compensation) or 4-Pole (Kelvin sensing) user selectable 2-Pole 0.12 to 99.99 k; 4-Pole 0.02 to 99.99 k Accuracy ± 2 % of Reading + 2 cts Test Voltage 16 VDC (+, - or auto polarity) Test Current Up to 250 mA max Data Storage Memory Capacity 512 test results (64 kB) Communication Optically Isolated USB Power Supply 9.6 V rechargeable battery pack (included) Recharging Source 110 V/220 V, (50/60) Hz external charger with 18 VDC, 1.9 A output Consult factory for NIST Calibration prices IP 53 cover closed The Model 6472 provides an automated way to measure the value of the earth/ground using the Fall-of-Potential method and storing measurements. PRODUCT INCLUDES Carrying bag, (110/240) V power adapter with US power cord, optical USB cable, rechargeable NiMH battery, and a USB drive with DataView® software, ground tester workbook and user manual. TEST KITS 6472 METER 300 ft Kit: Catalog #2135.53 500 ft Kit: Catalog #2135.54 (shown) Refer to page 75 for Model 6472 Kit descriptions Catalog #2135.35, #2135.36 and #2135.37 2 probes required to perform stakeless testing ACCESSORIES MN82 CURRENT PROBE (2 mA to 10 Arms) Catalog #2135.71 SR182 CURRENT PROBE (0.5 mA to 40 Arms) Catalog #2135.72 REEL CADDY Catalog #2135.85 Set of (2), for use with ground kit spools Vol. 23 Rev.00 02/2023 Technical Assistance (800) 343-1391 © Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved. www.aemc.com 73 GROUND RESISTANCE TESTERS MULTI-FUNCTION LARGE FUNCTIONAL DISPLAYS FEATURES · Ground Integrity Measurement · Ground Resistance testing using the 2-clamp method (no auxiliary rods needed) · 2- and 4-Point Bond Resistance/Continuity measurement (DC Resistance) with automatic polarity reversal · 3-Point Fall-of-Potential measurement with manual or automatic frequency selection · 4-Point Soil Resistivity measurement with automatic calculation of Rho (Ã) and user selection of the Wenner or Schlumberger test method · 3-Point Earth Coupling measurement · Manual and Automatic frequency scan from (41 to 5078) Hz for optimum test accuracy in electrically noisy environments · Selectable test voltage of (10, 16, 32 or 60) V up to 250 mA of test current (model dependant) · Auto Power OFF feature · Automatic recognition of all electrode connections and their resistance value · Stores up to 512 complete test results in internal memory · Display with automatic backlight when entering a function · Optically isolated USB communication cable included · Rechargeable NiMH batteries from wall charger or vehicle power (Cat. #2135.43 needed for vehicle power) · Rugged dustproof and water-resistant field case (IP53 rated in closed position) · Grounding standards IEC 61557 parts 4 and 5 compliant · Includes DataView® software for set up, data retrieval, real-time display, analysis, report generation and system configuration · Can also be used for continuity tests on bonding 2 probes required to perform stakeless testing. 4-POINT BOND TEST The 4-Point Bond test shows lead connections, bond resistance test results, test voltage and current SCHLUMBERGER TEST The Schlumberger test displays test lead connection, soil resistivity (Ã) test results and electrode spacing DATA STORAGE Memory Recall displays test results stored at a specific memory location 3-POINT FALL-OF-POTENTIAL TEST The 3-Point Fall-of-Potential test displays test lead connection, grounding rod resistance and test electrode resistances TWO CLAMP TEST The 2-Clamp method displays clamp connection resistance, test current and frequency WENNER TEST The Wenner test displays test lead connection, soil resistivity (Ã) test results, electrode spacing and resistance CATALOG NO. 2135.48 2135.49 2135.50 2135.51 2135.53 2135.54 2135.60 2135.61 DESCRIPTION Ground Resistance Tester Model 6471 (Digital, 3-Point, 4-Point, Clamp-on (SR182 probes not included), DataView® Software) Ground Resistance Tester Model 6471 (Digital, 3-Point, 4-Point, Clamp-on, (includes 2-SR182 probes), DataView® Software) Ground Resistance Tester Model 6471 Kit 300 ft (Catalog #2135.49 and Catalog #2135.36) Ground Resistance Tester Model 6472 (Digital, 2-Point, 3-Point, 4-Point, Bond Test, DataView® software) Ground Resistance Tester Model 6472 Kit 300 ft (Catalog #2135.51 and Catalog #2135.36) Ground Resistance Tester Model 6472 Kit 500 ft (Catalog #2135.51 and Catalog #2135.37) Ground Resistance Tester Model 6471 Kit 300 ft w/o Probes (Catalog #2135.48 and Catalog #2135.36) Ground Resistance Tester Model 6471 Kit 500 ft w/o Probes (Catalog #2135.48 and Catalog #2135.37) 74 www.aemc.com Technical Assistance (800) 343-1391 © Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved. Vol. 23 Rev.00 02/2023 GROUND RESISTANCE TESTERS MULTI-FUNCTION GROUND TESTERS MODELS 6471 & 6472 -- TYPICAL DATAVIEW® FUNCTIONAL DISPLAYS 2-CLAMP METHOD SETUP FALL-OF-POTENTIAL, STEP-TOUCH POTENTIAL SELECTIVE 3-POINT TESTING OF MULTIPLE RODS 4-POINT BONDING FOR VERY LOW RESISTANCE BONDING SOIL RESISTIVITY OPTIONAL KITS 150 FT KIT Catalog #2135.35 Test Kit for 3-Point testing includes carrying bag, (2) 150 ft color-coded (red/blue) leads on spools, (2) 5 ft color-coded (red/blue) leads, (1) 30 ft lead (green), (2) 14.5 in T-shaped auxiliary ground electrodes, a set of (5) spaded lugs and (1) 100 ft tape measure. 300 FT KIT Catalog 2135.36 Test Kit for 4-Point testing includes carrying bag, (2) 300 ft colorcoded (red/blue) leads on spools, (2) 5 ft color-coded (red/blue) leads, (2) 100 ft hand-tied color-coded leads (green/black), (4) 14.5 in T-shaped auxiliary ground electrodes, a set of (5) spaded lugs and (1) 100 ft tape measure. 500 FT KIT Catalog #2135.37 Test Kit for 4-Point testing includes carrying bag, (2) 500 ft color-coded (red/blue) leads on spools, (2) 5 ft color-coded (red/blue) leads, (2) 100 ft hand-tied color-coded (green/black) leads, (1) 30 ft lead (green), (4) 14.5 in T-shaped auxiliary ground electrodes, a set of (5) spaded lugs and (1) 100 ft tape measure. Vol. 23 Rev.00 02/2023 Technical Assistance (800) 343-1391 © Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved. www.aemc.com 75 GROUND RESISTANCE TESTERS MULTI-FUNCTION GROUNDFLEX® FIELD KIT Test active tower grounds safely without de-energizing or disconnecting any cables Unique in the industry! SPECIFICATIONS MODELS ELECTRICAL 3-POINT METHOD Range (Auto-Ranging) 0.09 to 99.9 k 4-POINT & SELECTIVE METHODS 0.011 to 99.99 k Resolution (0.01 to 100) (0.001 to 10) IP 53 cover closed 6472 & 6474 GROUND MEASUREMENT WITH 2 CLAMPS SOIL RESISTIVITY GROUND POTENTIAL MEASUREMENT (0.1 to 500) 0.01 to 99.9 k 0.01 mV to 65.00 V (0.01 to 1) (0.01 to 100) (0.01 to 10) mV DC RESISTANCE MEASUREMENT 0.02 to 99.99 k 2 wires: (0.01 to 100) 4 wires: (0.001 to 10) MEASUREMENTS WITH 6474 0.067 to 99.99 k (0.001 to 10) Accuracy ± (2 % + 1 count) ± (10 % + 1 count) ± (2 % + 1 count) ± (5 % + 1 count) ± (2 % + 2 counts) ± (5 % + 1 count) No-Load Voltage Measurement Frequency Coupling Measurement (10, 16, 32 or 60) Vrms (Not applicable w/2-clamp method) Auto: 1611 Hz (41 to 5078) Hz Manual: (128, 1367, 1611, (41 to 128) Hz (41 to 5078) Hz or 1758) Hz Yes ± 16 VDC DC (10, 16, 32 or 60) Vrms (41 to 5078) Hz Auxiliary Rod Resistance Measurement Voltage Interference Soil Resistivity Type of Measurement Measurement Current MECHANICAL Memory/ Communication Dimensions/Weight Safety Safety Rating 0.14 to 99,9 k 3 wires 4 wires > 200 mAAC 2 clamps < 26 ARMS (W/SR182) < 5 ARMS (W/MN82) Maximum 60 V peak Wenner and Schlumberger 4 wires 3 wires > 200 mAAC 0.14 to 99,9 k 2 or 4 wires > 200 mADC GroundFlex® > 200 mAAC 512-record memory / Optically isolated USB (10.7 x 9.84 x 5.04) in (272 x 250 x 128) mm / Model 6472: 7.05 lb (3.2 kg) / Model 6474: 5.07 lb (2.3 kg) 50 V CAT IV, complies with IEC 61326-1 / IEC 61010 / IEC 61557-1-4-5 Consult factory for NIST Calibration prices GROUND TESTER 6472 KIT-500 FT Includes meter, rechargeable NiMH batteries, optical USB cable, power adapter (110/240) V with power cord 115 V US, (2) 500 ft color-coded leads on spools (red/blue), (2) 100 ft color-coded leads (hand-tied, green/black), (1) 30 ft lead (green), (4) T-shaped auxiliary ground electrodes, (1) 100 ft AEMC® tape measure, DataView® software, ground tester workbook, user manual on USB drive, (1) carrying bag for meter and (1) carrying bag for kit. GROUNDFLEX® FIELD KIT 6474 Catalog #2136.03 (Includes Ground Tester 6472 KIT-500 FT) Includes GroundFlex® Adapter Model 6474, Ground Tester Model 6472, (4) GroundFlex® sensors (16 ft/5 m) with (12) color-coded rings, connection lead, (2) extension leads on H reel (black/green) with color-coded alligator clips, (1) extra black and green alligator clip, (6) BNC extension leads, (1) calibration loop, (3) C-clamps, a carrying case with wheels and handle for meters, carrying bag for meter and kit, (1) inverter 12 VDC to 120 VAC 200 watt (vehicle use) and user manual. SHOWN: 6474 KIT 76 www.aemc.com Technical Assistance (800) 343-1391 © Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved. Vol. 23 Rev.00 02/2023 GROUND RESISTANCE TESTERS GROUNDFLEX® FIELD KIT FEATURES · Ground Integrity Measurement · 3- and 4-Point Fall-of-Potential measurement with manual or automatic frequency selection · 4-Point soil resistivity measurement with automatic calculation of Rho (Ã) and user selection of the Wenner or Schlumberger test method · 2- and 4-Wire DC resistance measurement (Bond testing) with automatic polarity reversal · 3-Point Earth coupling measurement · Automatic frequency scan from (41 to 5078) Hz for optimum test accuracy in electrically noisy environments · Selectable test voltage limit of (10,16, 32, or 60) V with up to 250 mA of test current · Automatic recognition of all electrode connections and measurement of their resistance value · Determines bonding condition of overhead ground conductors · Auto Power OFF management · Optically isolated USB communication · Remote set up and operation of all measurements using DataView® software supplied · Rechargeable NiMH batteries from wall charger or vehicle power (Cat. #2135.43 needed for vehicle power) · Rugged dustproof and water-resistant field case (IP53 rated in closed position) · Includes DataView® software for data retrieval, real-time display, analysis, automatic report generation and system configuration AUTOMATIC RECOGNITION AND DISPLAY OF INPUT CONNECTIONS TO MATCH TEST The connections are displayed and flash if incorrect or absent for the test selected. Overhead ground conductor High voltage line Current injection rod RH H S ES E 6472 Potential measurement rod RS 4 1 3 2 1 2 3 4 6474 4 AmpFlex® channels connected GROUND MEASUREMENT ON TOWERS WITH GROUND CABLE High-voltage lines are usually equipped with a ground cable to allow lightning to discharge to ground via the tower. As all the towers are connected to this conductor, all the tower's resistances are in parallel. This means it is impossible to measure tower resistance using traditional 3-Point methods unless the ground cable is disconnected, which is a dangerous and time-consuming operation. ACCESSORIES CAT #2135.87 GroundFlex® Sensor 32 ft (10 m) (Model 6474 only) CAT #2135.72 Model SR182 AC Current Probe (Models 6471 & 6472) CAT #2135.86 Lead BNC 150 ft (46 m) M/F Extension Lead (Model 6474 only) CATALOG NO. 2136.03 DESCRIPTION GroundFlex® Field Kit Model 6474 (Tower Tester) Vol. 23 Rev.00 02/2023 Technical Assistance (800) 343-1391 © Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved. www.aemc.com 77 GROUND RESISTANCE TESTERS SELECTION CHART AEMC MODEL NUMBER AEMC CATALOG NUMBER RESISTANCE RANGE POWER SOURCE 2 POINT TEST 3 POINT TEST 4 POINT/ SELECTIVE SOIL RESISTIVITY TEST EARTH COUPLING 2 CLAMP BONDING DISPLAY VOLTAGE INDUCTANCE SWEEP INDICATION INDICATION FREQUENCY 6416 2141.01 (0.01 to 1500) Battery Clamp-On Ground Resistance Tester w/Alarm and Memory ü ü** Digital Voltage ü 6417 2141.02 (0.01 to 1500) Clamp-On Ground Resistance Tester Battery w/Alarm, Memory and Bluetooth communication Displayed ü ü (noise icon, ** Digital buzzer) ü 6418 2141.03 (0.01 to 1200) Battery Clamp-On Ground Resistance Tester w/Alarm and Memory ü ü** Digital Noise Icon 6422 2135.55 0.05 to 50 k Battery ü ü Digital Noise Icon 6422 Kit 150 FT 2135.56 0.05 to 50 k Rechargeable Battery ü 6424 2135.57 0.05 to 50 k Rechargeable Battery ü ü Digital Noise Icon ü Digital Noise Icon 6424 Kit 150 FT 2135.58 6424 Kit 300 FT 2135.59 GroundFlex® Field Kit 2136.03 Model 6474 6471 (SR182 probes 2135.48 not included) 6471 2135.49 6471 Kit 300 FT 2135.50 (with probes) 6471 Kit 300 FT 2135.60 (no probes) 6471 Kit 500 FT 2135.61 (no probes) 0.05 to 50 k 0.05 to 50 k 0.001 to 99.99 k 0.001 to 99.99 k 0.001 to 99.99 k 0.001 to 99.99 k 0.001 to 99.99 k 0.001 to 99.99 k Rechargeable Battery Rechargeable Battery Rechargeable Battery Rechargeable Battery Rechargeable Battery Rechargeable Battery Rechargeable Battery Rechargeable Battery ü ü ü ü ü ü ü ü ü Digital Noise Icon ü Digital Noise Icon ü Digital Voltage Displayed ü*** ü üü üü üü üü Digital Voltage Displayed Digital Digital Voltage Displayed Voltage Displayed Digital Voltage Displayed Digital Voltage Displayed ü ü ü ü ü ü 6472 2135.51 0.001 to 99.99 k Rechargeable Battery 6472 Kit 300 FT 2135.53 0.001 to 99.99 k Rechargeable Battery 6472 Kit 500 FT 2135.54 0.001 to 99.99 k Rechargeable Battery 4620 2130.43 (0.0 to 1999) Battery ü 4620 Kit 150 FT 2135.19 (0.0 to 1999) Battery ü 4620 Kit 300 FT 2135.20 (0.0 to 1999) Battery ü 4620 Kit 500 FT 2135.21 (0.0 to 1999) Battery ü 4630 2130.44 (0.0 to 1999) Rechargeable Battery ü 4630 Kit 150 FT 2135.22 (0.0 to 1999) Rechargeable Battery ü ü ü ü ü ü* ü ü ü ü* ü*** ü ü*** ü ü*** ü Digital Digital Digital Voltage Displayed Voltage Displayed Voltage Displayed Digital LED/Buzzer Digital LED/Buzzer Digital LED/Buzzer Digital LED/Buzzer Digital LED/Buzzer Digital LED/Buzzer ü ü ü 4630 Kit 300 FT 2135.23 (0.0 to 1999) Rechargeable Battery ü 4630 Kit 500 FT 2135.24 (0.0 to 1999) Rechargeable Battery ü ü Digital LED/Buzzer Digital LED/Buzzer * Performing soil resistivity tests with this kit requires two additional auxiliary electrodes not supplied in the 150 ft kit and one additional test lead. ** Clamp-on Ground Resistance Tester can measure system continuity inclusive of all bonding points. *** Must purchase an additional (2) SR182 or (2) MN82 accessory clamps. 78 www.aemc.com Technical Assistance (800) 343-1391 © Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved. Vol. 23 Rev.00 02/2023 LEAKAGE CURRENT METERS & PROBES SEE WEBSITE FOR PRICING AND AVAILABILITY: WWW.AEMC.COM LEAKAGE CURRENT METERS & PROBES TRMS CLAMP-ON LEAKAGE CURRENT METER MODEL 566 Designed to measure low AC currents, which are typically leakage currents in ground conductors SPECIFICATIONS MODEL ACmA Current (TRMS, Auto-Ranging) Resolution 6 mA 60 mA 600 mA Accuracy (50 to 60) Hz (6 mA) (50 to 60) Hz (60 and 600 mA) (60 to 500) Hz (6 mA) (60 to 500) Hz (60 mA and 600 mA) AC Current (TRMS, Auto-Ranging) Resolution 6 A 60 A Accuracy (50 to 60) Hz (60 to 500) Hz AC Voltage (TRMS) Accuracy 60 V 600 V DC Voltage Resolution 60 V 600 V Accuracy 60 V 600 V Resistance Accuracy CONTINUITY Frequency (Auto-Ranging) Function Resolution (0 to 100) Hz 100 Hz to 1 kHz Sensitivity Accuracy Filter MAX Sample Rate MECHANICAL Jaw Opening | Max Conductor Size Weight Power Supply ENVIRONMENTAL Operating Temperature SAFETY Safety Rating Consult factory for NIST Calibration prices 566 0.001 mA (1 A) 0.01 mA (10 A) 0.1 mA (100 A) ± 1.0 % of Reading ± 8 cts ± 1.0 % of Reading ± 5 cts ± 2.0 % of Reading ± 8 cts ± 2.0 % of Reading ± 5 cts 1 mA 10 mA ± 1.0 % of Reading ± 5 cts ± 2.0 % of Reading ± 5 cts ± 1.0 % of Reading ± 3 cts 0.01 V 0.1 V ± 1.0 % of Reading ± 2 cts (0 to 1) k ± 1.0 % of Reading ± 2 cts Buzzer activates < 45 (0 to 1) k A-Hz V-Hz 0.1 Hz 1 Hz 0.1 Hz 1 Hz 10 mArms min 5 Vrms min ± 0.5 % of Reading ± 2 cts On (50/60) Hz only; Off (full frequency range) 100 ms 0.91 in (23 mm) 10.4 oz (296 g) with batteries (2) 1.5 V AAA batteries (included) (32 to 104) °F (0 to 40) °C; < 80 % RH (non-condensing) EN 61010-1, EN 61010-2-032, 600 V CAT III PRODUCT INCLUDES Soft carrying case, (2) color-coded (red/black) 5 ft test leads, (2) 1.5 V AAA (LR03) batteries and user manual. Jaw Opening: .91 in (23 mm) FEATURES · Check for leakage and locate insulation breakdowns on live circuits · Measures leakage current down to 0.001 mA with up to 1 A resolution · Measures current up to 60 Arms · Measures up to 600 VAC/DC · Measures Hz on either V or A inputs · Measures resistance and continuity · Hold feature freezes value · MAX feature keeps track of highest measured in-rush value · Zero button ideal for measuring relative values · Low pass filter to isolate (50/60) Hz fundamental from harmonics · Compatible with VDE 0404 · Backlight LCD display LOAD CATALOG NO. 2139.83 DESCRIPTION TRMS Clamp-on Leakage Current Meter Model 566 (6/60/600 mA, 1/10/100 A, 600 VAC/DC, Hz, Ohms, Continuity) 80 www.aemc.com Technical Assistance (800) 343-1391 © Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved. Vol. 23 Rev.00 02/2023 LEAKAGE CURRENT METERS & PROBES ARTIFICIAL NEUTRAL & LEAKAGE CURRENT PROBE MODEL 2620 Check for leakage and locate insulation breakdowns on live circuits SPECIFICATIONS MODEL 2620 ELECTRICAL 4 A Range 400 A Range Current Range 500 µA to 4 A 500 mA to 400 A Output Signal 1 mV/mA (4 V max) 1 mV/A (400 mV max) Accuracy 500 µA to 10 mA ± 3 % of Reading ± 1 mV (10 to 100) mA ± 0.5 % of Reading ± 0.5 mV 100 mA to 4 A ± 0.5 % of Reading ± 0.5 mV 500 mA to 10 A ± 0.5 % of Reading ± 0.5 mV (10 to 100) A ± 0.35 % of Reading ± 0.5 mV 10 A to 400 A ± 0.35 % of Reading ± 1 mV Phase Shift 500 µA to 10 mA (10 to 100) mA < 15 ° 100 mA to 4 A < 10 ° 500 mA to 10 A (10 to 100) A < 1 ° (100 to 400) A < 0.6 ° Load Impedance 1 M min Frequency Range (48 to 1000) Hz MECHANICAL Dimensions (11.22 x 6.89 x 1.77) in (285 x 175 x 45) mm Weight 2.87 lb (1.3 kg) Jaw Opening 4.4 in (112 mm) Maximum Conductor Size 4.4 in (112 mm) ENVIRONMENTAL Operating Temperature (-14 to 131) °F (-10 to 55) °C; Up to 85 % RH (non-condensing) SAFETY Safety Rating EN 61010-2-032, 600 V CAT III Consult factory for NIST Calibration prices Jaw Opening: 4.4 in (112 mm) Conductor Size: 4.4 in (112 mm) FEATURES · Very high sensitivity · Differential or leakage current from 500 µA · Current up to 400 A · Two switch-selectable measurement ranges: 4 AAC/400 AAC · Large inside jaw diameter allows use on large or multiple conductors · Works with single-, dual- and three-phase systems · Connect directly to DMMs on mV or VAC range CATALOG NO. 2125.52 DESCRIPTION Leakage Current Probe Model 2620 (4 A, 1 V/A & 400 A, 1 mV/A output) Vol. 23 Rev.00 02/2023 Technical Assistance (800) 343-1391 © Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved. www.aemc.com 81 As a businesWseoaf rtehecoCmhamuivttinedArtonoeunxv®irognrmouepn,taolurepsrpoodnuscibtsiliatyre. backed by over 130 yeaOrusropfreoxdpuecrtiednecseigannsdaenxdcperlolednuccetiionnteasret abnadsemdeasurement instrumentsoannedsteanbcloismhipnagssa tbhaelalantceestbeinttweerneantieonnvailrosntamnednatradls, for quality econaonmd isca, faentyd. sWoeciarlecothnedibtiroannsdiynofuutcuarne tsroucsite!ties. We are the brand you can trust! MEGOHMMETERS DATA ANALYSIS AND REPORTING SOFTWARE SEE PAGE 133 FOR MORE INFO ON DATAVIEW® SOFTWARE CONFIGURE MEGOHMMETERS MODELS 1060, 5060, 5070, 6526, 6534, 6550 & 6555 Print reports of all test results / Select test voltage and run tests from your PC with a simple click and execute process / Capture and display data in real-time / Retrieve data from the instrument's memory SEE WEBSITE FOR PRICING AND AVAILABILITY: WWW.AEMC.COM MEGOHMMETERS 500 V & 1000 V HAND-CRANKED MODEL 6503 Designed for acceptance testing and preventive maintenance of wiring, cables, switchgear and motors Ideal for use in areas affected by floods SPECIFICATIONS MODEL 6503 INSULATION TESTS Test Ranges* 250 V 500 V 1000 V (1 to 500) M (1 to 500) M (10 to 5000) M (5 G ) Short Circuit Current 5 mA (max) Voltage Measurement/ Safety Check (0 to 600) VAC Accuracy (M) ± 2.5 % of Full Scale Length Automatic Discharge 8 s/µF Charge Time 250 V 500 V 1000 V 0.2 s/µF 0.5 s/µF 0.5 s/µF RESISTANCE TESTS Measurement Range Test Current Accuracy CONTINUITY TESTS Measurement Range Test Current Accuracy SAFETY Safety Rating EN 61010-1, 600 V CAT II, 300 V CAT III *DC test voltage generated in full across the entire measurement range. Consult factory for NIST Calibration prices PRODUCT INCLUDES MODEL 6503 Soft carrying case, (3) color-coded (red/black/blue) leads and alligator clips, black test probe and a user manual. IP 54 FEATURES · True Megohmmeter® · No batteries or power needed to operate · Test voltages of (250, 500, and 1000) V · Insulation measurements to 5000 M · LED indicates constant voltage output and proper cranked speed controlled by voltage regulator · Automatic discharge when measurement is finished · Auto-Ranging dual scale operation for better sensitivity and easier readings · Compact self-contained package; folded crank · Voltage displayed prior to, during and at the end of test · Large direct reading scale CATALOG NO. 2126.52 DESCRIPTION Megohmmeter Model 6503 (Hand-cranked, 250 V, 500 V, 1000 V) 84 www.aemc.com Technical Assistance (800) 343-1391 © Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved. Vol. 23 Rev.00 02/2023 MEGOHMMETERS 1000 V DIGITAL MODEL 6527 Insulation tester with DMM functions specially designed for testing wiring, small motors and other equipment SPECIFICATIONS MODEL 6527 Range INSULATION TESTS (250 V) 4 M 40 M 400 M 4000 M (4G ) Resolution Accuracy Test Current 0.001 M 0.01 M 0.1 M 1 M ±2 % of ±3 % of ±4 % of Reading ±10 cts Reading ±5 cts Reading ±5 cts 1 mA test current into a 250 k load INSULATION TESTS (500 V) Resolution Accuracy Test Current 0.001 M 0.01 M 0.1 M 1 M ±2 % of ±2 % of ±4 % of Reading ±10 cts Reading ±5 cts Reading ±5 cts 1 mA test current into a 500 k load INSULATION TESTS (1000 V) Resolution Accuracy Test Current 0.001 M 0.01 M 0.1 M 1 M ±3 % of ±2 % of ±2 % of ±4 % of Reading ±10 cts Reading ±10 cts Reading ± 5 cts Reading ±5 cts 1 mA test current into a 1 M load VOLTMETER RANGES (250 V, 500 V, & 1000 V) V AC/DC 600 V 1000 V Resolution Accuracy DC AC Input Impedence DC AC RESISTANCE TESTS - OHMMETER 1 V ±0.8 % of Reading ±3 cts ±1.2 % of Reading ±10 cts 10 M 10 M (40/400) Hz Range (0 to 400) k Resolution 0.1 k Accuracy ±1.2 % of Reading ±3 cts CONTINUITY TESTS Range (0 to 400) Resolution 0.01 0.1 Accuracy 1.2 % ±3 cts Test Current > 200 mA (0.2/2) Test Lead Compensation Yes: Dedicated push-button Beeper Yes: < 35 ±3 ELECTRICAL Power Supply (6) 1.5 V AA batteries Alkaline recommended (included) SAFETY Safety Rating IP Protection EN 61557, 600V Cat. IV IP51 Consult factory for NIST Calibration prices PRODUCT INCLUDES Soft carrying case, set of (2) 5 ft color-coded test leads with alligator clips, (1) black test probe and user manual. IP 51 FEATURES · True Megohmmeter® · Insulation test voltage selections of (250, 500, and 1000) V · Measure insulation to 4000 M (4 G) · TEST LOCK feature for time sensitive measurements up to 15 minutes · Auto discharge after insulation test · AC/DC voltmeter to 600 VAC/ 1000 VDC · Ohmmeter to 400 k · Continuity meter with > 200 mA test current · Test lead resistance compensation for accurate low resistance measurements · Auto HOLD function to "freeze" readings · Large and bright dual display with blue backlight · Auto Power OFF feature · Ergonomic over-molded case with back-stand CATALOG NO. 2126.53 DESCRIPTION Megohmmeter Model 6527 (Digital 250 V, 500 V, 1000 V, Continuity, 400 k, V) Vol. 23 Rev.00 02/2023 Technical Assistance (800) 343-1391 © Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved. www.aemc.com 85 MEGOHMMETERS 1000 V DIGITAL & MULTI-FUNCTION HANDHELD MODEL 6529 Insulation tester ideal for maintenance and repair operations on electrical equipment such as motors, cables, and more. SPECIFICATIONS US Design Patent US D890,617 S MODEL 6529 AC/DC VOLTAGE MEASUREMENT Range 700 VAC, 700 VAC+DC Accuracy DC AC+DC ± (1 % R + 1 ct) ± (1.2 % R + 1 ct) Resolution 1 V Frequency Range DC & (30 to 440) Hz Input Impedance 25 M INSULATION MEASUREMENT Test Voltage/Resistance Range 50 V 100 V 250 V 500 V 1000 V Measurement Accuracy 40 /40 M/400 M 4.2 G 11 G (0.010 to 420.0) M (0.020 to 420.0) M (0.050 to 4200) M (0.100 to 4200) M 0.20 M to 11.00 G ± (1.5 % R + 10 ct) ± (4 % R + 10 ct) ± (10 % R + 10 ct) (1000 V range) CONTINUITY MEASUREMENT Range (0 to 40) (200 mA test current 2 ) Accuracy 1.2 % R +3 ct Resolution Max 0.01 Leads Compensation Up to 5 Threshold Audible signal triggered, Selectable 1 or 2 RESISTANCE MEASUREMENT Range (0 to 420) k (Auto ranging) Accuracy ± (1.2 R + 3 ct) Resolution Max 0.1 DMR Mode Compares successive measurements to a reference value with alarm indication and red backlit display if deviation changes by the programmed %. The difference between the new reading and the reference measurement, along with the % deviation is displayed. GENERAL Time Test 10 s to 39.59 min selectable Display LCD with backlight Power Supply (6) AA alkaline batteries (NEDA 15 A or IEC LR6) Battery Life (5 s ON, 25 s OFF) > 2000 measurement in M, > 300 h in VAC/DC, > 6000 measurement in Continuity Test Dimensions (8.54 x 3.54 x 2.44) in (217 x 90 x 62) mm Weight 1.68 lb (762 g) Operating Temperature (14 to 122) °F (-10 to 50) °C, 90 % RH SAFETY Safety Rating IEC / EN 61010-1, 600 V CAT IV, CE mark ® C US LISTED Consult factory for NIST Calibration prices PRODUCTS INCLUDE Includes soft carrying case, set of (2) 5 ft color-coded (red/black) silicone leads and alligator clips, (2) color- coded (red/black) test probes (Rated 1000 V CAT IV, UL V2), (6) 1.5 V AA batteries and user manual. IP 40 with leads connected FEATURES · Selectable test voltages (50, 100, 250 , 500 and 1000) V · Basic DMM functions; Volts, Continuity, Resistance · DAR and PI ratio test functions · Dual line display to view the insulation value and real-time test voltage simultaneously in an easy-to-read format · DMR mode - relative resistance comparison to a reference value · 2-color backlighting easily shows alarm conditions · Shockproof sheath for excellent handling · Automatic power-off function to optimize the battery life · Programmable alarm thresholds ACCESSORIES/REPLACEMENTS Catalog #2138.54 Continuity probe Catalog #2119.02 Soft carrying pouch Catalog #2971.04 Fuse Set of (2) FF, 200 mA, 1000 V, 10 kA, (6 x 32) mm Catalog #5000.94 Lead Set of (2) 5 ft color-coded (red/ black) silicone leads with 4 mm straight/ right angle banana plugs (Rated 1000 V CAT IV, UL) Catalog #5000.97/#5000.98 Black/red test probe (1000 V CAT IV, 15 A, UL V2) Cat #5000.99/#5100.00 Clip Safety alligator (black/red) (1000 V CAT IV, 15 A, UL V2) CATALOG NO. 2126.55 DESCRIPTION Megohmmeter Model 6529 (Digital, 50 V, 100 V, 250 V, 500 V, 1 kV, 420 k-Ohm, Continuity, Alarm, Timer & PI/DAR) 86 www.aemc.com Technical Assistance (800) 343-1391 © Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved. Vol. 23 Rev.00 02/2023 MEGOHMMETERS DIGITAL/ANALOG & MULTI-FUNCTION HANDHELD MODELS 6522, 6526, 6534 & 6536 6522 & 6526 - ideal for testing cables, small motors, pumps, transformers and industrial equipment 6534 - ideal for insulation measurements on communication cables, Ethernet cables and other low voltage DC wiring 6536 - ideal for special applications in the aerospace and defense sectors and for ESD testing where specific test voltages are required 6522 6526 SPECIFICATIONS MODELS 6522 6526 6534 6536 INSULATION TESTS Test Voltages (250, 500, and 1000) V (50, 100, 250, 500, and 1000) V (10, 25, 100, 250, and 500) V Variable (10 to 100) V (1 V steps) Insulation Resistance 40 G (40,000 M) 200 G (200,000 M) 50 G (50,000 M) 20 G (20,000 M) PI/DAR Ratios No Yes No Test Lock Yes Timer (0 to 40) min Auto Discharge Yes Automatic Test Inhibit > 25 V DMM FUNCTIONS 6534 Voltage 700 VAC/DC Resistance 1000 k Continuity 10 10 , 100 Test Current 200 mA Capacitance Measurement 0.1 n to 10 µF Frequency GENERAL FUNCTIONS Alarm / Rel NO/NO Auto Power OFF Data Hold Test Lead Compensation Remote Probe Memory Bluetooth DataView® Software Display Type Display Counts Backlight Power Supply Magnetic Mount SAFETY Safety Rating Consult factory for NIST Calibration prices (15.3 to 800) Hz Yes / Yes Yes Yes (optional) 1300 measurements 2.1 Class II Included Digital w/Analog Bargraph 4000 Yes (6) AA Alkaline Yes 600 V CAT IV 6536 6526 & 6534 (only) IP 54 CATALOG NO. 2155.51 2155.53 2155.55 2155.56 2155.57 DESCRIPTION Megohmmeter Model 6522 (Digital w/Analog Bargraph, 250 V, 500 V, 1000 V, Continuity, V) Megohmmeter Model 6526 (Digital w/Analog Bargraph, Alarm, 50 V, 100 V, 250 V, 500 V, 1000 V, Ohm, Continuity, V, k, Capacitance, Memory, Bluetooth w/DataView® software) Megohmmeter Model 6534 (Digital w/Analog Bargraph, Alarm, 10 V, 25 V, 100 V, 250 V, 500 V, Ohm, Continuity, V, k, Memory, Bluetooth w/DataView® software) Megohmmeter Model 6536 (Digital w/Analog Bargraph, Alarm, Variable (10 to 100) V, Ohm, Continuity, V, k) Megohmmeter Model 6536 ESD Floor Kit (Meter, set of (2) 5 lb weights and carrying case) Vol. 23 Rev.00 02/2023 Technical Assistance (800) 343-1391 © Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved. www.aemc.com 87 MEGOHMMETERS DIGITAL/ANALOG & MULTI-FUNCTION HANDHELD MODELS 6522, 6526, 6534 & 6536 FRONT PANEL & FUNCTIONAL DISPLAYS Analog with bargraph display of insulation resistance Secondary display Main display Function indicators PRODUCT INCLUDES 6522 Soft carrying case, (2) 5 ft color-coded (red/black) leads, (2) color-coded (red/black) alligator clips, (1) black test probe, (6) AA batteries and user manual. 6526 Soft carrying case, (2) 5 ft color-coded (red/black) leads, (2) color-coded (red/black) alligator clips, (1) black test probe, (6) AA batteries, quick start guide, USB stick with DataView® software and user manual. 6534 Soft carrying case, (2) 5 ft color-coded (red/black) leads, (2) color-coded (red/black) alligator clips, (1) black test probe, (2) color-coded (red/black) grip probes, (6) AA batteries, quick start guide, USB stick with DataView® software and user manual. 6536 Soft carrying case, (2) 5 ft color-coded (red/black) leads, (2) color-coded (red/black) alligator clips, (1) black test probe, (2) color-coded (red/black) grip probes, (6) AA batteries, and user manual. 6536 ESD FLOOR KIT Field case, (2) 5 ft color-coded (red/black) leads, (2) color-coded (red/ black) alligator clips, (1) black test probe, (2) color-coded (red/black) grip probes, (2) 5 lb weights with conductive rubber bottom pad, (2) 4 mm non-insulated adapters, (6) AA batteries, and user manual. SHOWN: 6526 Access to the instrument information and setup for Test Lock, Timer, PI/DAR and Times Navigation buttons: · Display instrument information · Turn buzzer ON or OFF · Turn power saver ON or OFF · Program test time · Select displayed parameters · Program alarm set points Memory recall/ Bluetooth activation Alarm activation/deactivation with Pass/Fail indication (model dependent) Test lead resistance compensation Rel set and compare measurements to a reference value Test button Test function selection switch IP 54 6526, 6532 & 6534 FEATURES* · True Megohmmeter® · Test voltage from (10 to 1000) V · Insulation resistance up to 200 G · Manual, Lock, Timer modes & PI/DAR Ratio calculations · Alarms with Green/Red Pass/Fail indicator light · 200 mA/20 mA continuity with active protection without fuses · Measurement of V (TRMS & DC), F, , k, Hz, C · Rel mode for comparison measurements · Configurable alarms · Data retrieval · Automatic discharge after test · Automatic test inhibit if device under test is energized > 25 V * Features are model dependent. Bluetooth on selected models. 88 www.aemc.com Technical Assistance (800) 343-1391 © Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved. Vol. 23 Rev.00 02/2023 MEGOHMMETERS 1000 V DIGITAL/ANALOG MODEL 1060 Test insulation on cables, transformers, motors and wiring installations SPECIFICATIONS MODEL 1060 INSULATION TESTS Test Voltage 50 V 100 V 250 V 500 V 1000 V Accuracy 2 k to 40 G 40 G to 4 T Voltage Test/Safety Check Voltage Warning Indicator Test Inhibition Smooth Function RESISTANCE TESTS Measurement Range Test Voltage Test Current Accuracy > 4 k CONTINUITY TESTS Measurement Range Test Current Accuracy COMMUNICATION Memory of Reading over Time R(t) Memory of Test Results in Files PC Software/Report Generation ELECTRICAL 2 k to 200 G 4 k to 400 G 10 k to 1000 G (1 T) 20 k to 2000 G (2 T) 40 k to 4000 G (4 T) ± 5 % of Reading ± 3 cts ± 15 % of Reading ± 10 cts (0 to 1000) VAC/DC > 25 V Yes > 25 V Yes 0.01 to 400 k 12.4 VDC max < 6 mADC ± 3 % of Reading ± 3 cts (0.01 to 39.99) 200 mA from (0.01 to 20.00) ± 3 % of Reading ± 4 cts Yes (128 kB memory) 128 kB memory with RS-232 to USB adapter (included) DataView® (included) Power Supply SAFETY Safety Rating 9.6 V NiMH Battery Pack (included) (85 to 256) V ((50/60) Hz) EN 61010-1, 600 V CAT III, EN 61557 Consult factory for NIST Calibration prices PRODUCT INCLUDES Detachable accessory pouch, (2) 5 ft color-coded (red/blue) leads, (1) black shielded lead, (3) color-coded (red/black/blue) alligator clips, (1) black test probe, (1) RS-232 DB9 F/F 6 ft null model cable, (1) RS-232 to USB adapter, US 115 V power cord, rechargeable NiMH battery, spare fuses, and a USB drive with DataView® software and user manual. IP 54 FEATURES · True Megohmmeter® · Test voltage selections of (50, 100, 250, 500 and 1000) V · Insulation measurements to 4000 G (4 T) · Direct measurement of DAR and PI values · Direct measurement of sample capacitance · Display of test voltage and run time · Programmable test run times and PI times · Smooth and Alarm functions · Automatic test inhibition (if live sample > 25 V) · Automatic discharge and display of discharge voltage · Large dual display with time, voltage and measurement · Bright blue electroluminescent backlight · Auto Power OFF when not in use · Remote operation with optional test probe · Rugged, dual wall, water-resistant field case with detachable lead/accessory pouch ACCESSORIES CATALOG #2155.75 Megohmmeter test probe (600 V CAT IV) CATALOG NO. 2130.03 DESCRIPTION Megohmmeter Model 1060 (Digital, with Analog Bargraph, Backlight, Alarm, Timer, 50 V, 100 V, 250 V, 500 V, 1000 V, Auto DAR/ PI, Resistance, Continuity, DataView® software, 128 kB Memory) Vol. 23 Rev.00 02/2023 Technical Assistance (800) 343-1391 © Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved. www.aemc.com 89 MEGOHMMETERS 5000 V DIGITAL/ANALOG MODEL 6505 Contributes to the safety of electrical installations and equipment SPECIFICATIONS MODEL INSULATION TESTS Test Voltage/Range 500 V 1000 V 2500 V 5000 V User Programmable Test Short Circuit Current Accuracy 10 k to 399.9 G 400 G to 10 T DAR (1 min / 30 s) PI (10 min / 1 min & User Programmable) Capacitance Measurement Leakage Current Measurement Programmable PI Ratio Times Discharge After Test Discharge Voltage Display Voltage Test / Safety Check Voltage Warning Indicator Test Inhibition Guard Terminal ELECTRICAL Power Supply SAFETY Safety Rating Consult factory for NIST Calibration prices 6505 10 k to 2000 G (2 T) 10 k to 4000 G (4 T) 10 k to 10,000 G (10 T) 10 k to 10,000 G (10 T) (40 to 1000) V: 10 V increments (1000 to 5100) V: 100 V increments < 1.6 mA ± 5 % ± 5 % of Reading ± 3 cts ± 15 % of Reading ± 10 cts 0.02 to 50.00 0.02 to 50.00 (0.001 to 49.99) µF; Max resolution 1 nF 0.00 nA to 3 mA; Max resolution 1 pA (1 to 60) min Yes, automatic Yes 2500 VAC / 4000 VDC (16 to 42) Hz / 1 V Resolution Yes > 25 V > 40 % of test voltage Yes (1) 9.6 V NiMH battery pack (included); Line power: (85 to 256) VAC (50/60) Hz EN 61010-1, 1000 V CAT III ACCESSORIES/REPLACEMENTS CATALOG #2133.73 Extra Large Tool Bag CATALOG #2960.21 9.6 V rechargeable NiMH battery pack CATALOG #2151.30 Lead Replacement set of (3), 10 ft (5 kV) color-coded safety with clips (Jumper lead not included). CATALOG #2151.31 Lead Replacement 1 ft jumper lead (blue) CATALOG #2151.32 Lead Set of (3), 25 ft (5 kV) safety with clips CATALOG #2119.84 Fuse Set of (3), 0.1 A, 380 V, 5 x 20, 10 kA CATALOG #5000.14 Power Cord 115 V US Plug IP FEATURES 53 · True Megohmmeter® · Simple operation · Test voltage selections of (500, 1000, 2500 and 5000) V · Insulation measurements from 10 k to 10,000 G (10 T) · Adjustable and programmable test voltage (40 to 5100) V · Automatic calculation of DAR and PI values · Direct measurement and display of capacitance and leakage current · Display resistance, test voltage and run time · Programmable PI ratio times · Automatic test inhibition (if live sample > 40 % of test voltage) · Automatic discharge and display of discharge voltage · Large backlight LCD dual-display with time, voltage and measurements shown · Rugged, dual wall, water-resistant field case · Designed and built to IEC safety standards PRODUCT INCLUDES Extra large classic tool bag, set of (3) 10 ft color-coded (red/ black/blue) leads with clips (5000 V) (red/black/blue), (1) blue guard terminal jumper lead, fuse 0.1 A 380 V, rechargeable battery pack (installed), US 115 V power cord, and user manual. CATALOG NO. DESCRIPTION 2130.18 Megohmmeter Model 6505 (Digital, with Analog Bargraph, Backlight, 500 V, 1000 V, 2500 V, 5000 V, Auto DAR/PI) 90 www.aemc.com Technical Assistance (800) 343-1391 © Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved. Vol. 23 Rev.00 02/2023 MEGOHMMETERS 5000 V DIGITAL/ANALOG MODELS 5050 & 5060 Designed with the highest level of built-in safety features SPECIFICATIONS MODELS INSULATION TESTS Test Voltage 500 V 1000 V 2500 V 5000 V User Selectable Test Voltage Accuracy 10 k to 399.9 G 400 G to 10 T Voltage Test/Safety Check Voltage Warning Indicator Test Inhibition Smooth Function (user selectable) COMMUNICATION Storage of Readings over Time R(t) Storage of Test Results Communication Port PC Software/Report Generation ELECTRICAL Power Supply SAFETY Safety Rating Consult factory for NIST Calibration prices 5050 5060 10 k to 2000 G (2 T) 10 k to 4000 G (4 T) 10 k to 10,000 G (10 T) 10 k to 10,000 G (10 T) Programmable: (40 to 1000) V: 10 V increments; (1000 to 5100) V: 100 V increments ± 5 % of Reading ± 3 cts ± 15 % of Reading ± 10 cts 2500 VAC/4000 VDC Yes > 25 V Yes selectable at (3, 10, or 20) % of test voltage Digital filtering stabilizes display readings 4 kB memory 20 readings 128 kB memory 1500 readings Serial and RS-232 to USB adapter (included) DataView® (included) (1) 9.6 V NiMH battery pack (included) Line power: (85 to 256) V (50/60) Hz EN 61010-1, 600 V, CAT III 1000 V ACCESSORIES/REPLACEMENTS CATALOG #2119.45 PC RS-232 DB9 F/F 6 ft Null Modem Cable (5060 & 5070) CATALOG #2119.84 Fuse, set of (3), 0.1 A, 380 V, 5 x 20, .10 kA CATALOG #2133.73 Extra Large Classic Tool Bag (18 x 9 x 12) in CATALOG #2135.43 Inverter 12 VDC to 120 VAC 200 Watt for Vehicle use CATALOG #2136.80 Cable 10 ft USB Cable CATALOG #2140.46 Cable - 5 ft USB A-B Cable CATALOG #2151.30 Lead Replacement set of (3), 10 ft (5 kV) color-coded safety with clips (Jumper lead not included) CATALOG #2151.31 Lead Replacement 1 ft jumper lead (blue) CATALOG #2151.32 Lead Set of (3), 25 ft (5 kV) safety with clips CATALOG #2960.21 Battery Rechargeable 9.6 V CATALOG #5000.60 Adapter RS-232 to USB 2.0 (5060 & 5070) CATALOG #5000.14 US 115 V Power Cord USB THUMB DRIVE Supplied with DataView® software and user manual (5060 & 5070) 5050 5060 SAFETY IP R ATIN G 53 FEATURES 5060 only · True Megohmmeter® · Test voltage selections of (500, 1000, 2500, and 5000) V · Variable test voltage from (50 to 5100) V (model 5060) · Wide measurement range up to 10 T · Automatic discharge at the completion of the test · Measure AC voltage up to 4000 V · Automatic test inhibit if live voltage detected above a set value · Programmable alarms for all functions · Automatic calculation of DAR, PI and DD ratios · Large, backlit LCD screen with digital display and bargraph · Measures capacitance up to 49.99 µf · Stores up to 1500 measurements (model 5060) · Includes DataView® software for data retrieval, real-time display, analysis and report generation PRODUCT INCLUDES 5050, 5060 & 5070 Extra large classic tool bag, set of (3) 10 ft (5 kV) safety leads (red/ black/blue) with clips, one guard terminal jumper lead (blue), US 115 V power cord, rechargeable battery pack, and user manual (5050) CATALOG NO. 2130.20 2130.21 DESCRIPTION Megohmmeter Model 5050 (Digital, Analog Bargraph, Backlight, Alarm, Timer, 500 V, 1000 V, 2500 V, 5000 V, Auto DAR/PI/DD) Megohmmeter Model 5060 (Digital, Analog Bargraph, Backlight, Alarm, Timer, 500 V, 1000 V, 2500 V, 5000 V, Auto DAR/PI/DD, USB w/DataView® Software) Vol. 23 Rev.00 02/2023 Technical Assistance (800) 343-1391 © Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved. www.aemc.com 91 MEGOHMMETERS 5000 V GRAPHICAL MODEL 5070 Offers real-time graphic plot of measurements and digital presentation of test results SAFETY SPECIFICATIONS IP R ATIN G 53 MODEL 5070 INSULATION TESTS Test Voltage 500 V 1000 V 2500 V 5000 V 10 k to 2000 G (2 T) 10 k to 4000 G (4 T) 10 k to 10,000 G (10 T) 10 k to 10,000 G (10 T) FEATURES · True Megohmmeter® User Selectable Test Voltage Programmable: (40 to 1000) V: 10 V increments; (1000 to 5100) V: 100 V increments · Test voltage selections of (500, 1000, 2500, and 5000) V · Insulation measurements from 10 k to 10,000 G (10 T) Automatic Step Voltage Accuracy 10 k to 99.9 G 400 G to 10 T Voltage Test/Safety Check Voltage Warning Indicator Programmable step voltage and duration up to five steps. Three profiles can be stored. ± 5 % of Reading ± 3 cts ± 15 % of Reading ± 10 cts 2500 VAC/4000 VDC Yes > 25 V · Selectable and programmable test voltage (40 to 5100) V · Automatic calculation of DAR, PI and DD ratios · Calculations of Step Voltage through front panel · Direct measurement and display of capacitance and leakage current · Display resistance, test voltage and run time · Programmable test run times and PI ratio times Test Inhibition Smooth Function (user selectable) COMMUNICATION Yes -- selectable at (3, 10, or 20) % of test voltage Digital filtering stabilizes display readings · Smooth and Alarm functions · Automatic test inhibition (if live sample > (3, 10, or 20) % of test voltage) · Automatic discharge and display of discharge voltage Storage of Readings Over Time R(t) Storage of Test Results Communication Port PC Software/ Report Generation ELECTRICAL 128 kB memory Stores over 1500 test results Serial and RS-232 to USB adapter (included) DataView® (included) · Graphic and digital display of test voltage, resistance and more · Bright blue electroluminescent backlight · Programmable temperature compensation · Programmable test voltage lock-out · Programmable alarm setting · Auto Power OFF when not in use Power Supply SAFETY Safety Rating (1) 9.6 V NiMH battery pack (included) Line power: (85 to 256) V (50/60) Hz EN 61010-1, 1000 V CAT III Consult factory for NIST Calibration prices · AC or DC powered with rechargeable NiMH battery pack - run while charging · Rugged, water-resistant field case · Includes DataView® software for data retrieval, real-time display, analysis and report generation With the push of a button: Insulation Resistance measurement is graphically displayed at the completion of the test. ACCESSORIES/REPLACEMENTS CATALOG #2119.45 PC RS-232 DB9 F/F 6 ft Null Modem Cable (5060 & 5070) CATALOG #2119.84 Fuse, Set of (3), 0.1 A, 380 V, (5 x 20) mm, .10 kA CATALOG #2140.46 Cable - 5 ft USB A-B Cable CATALOG #2133.73 Extra large classic tool bag (18 x 9 x 12) in CATALOG #2135.43 Inverter 12 VDC to 120 VAC 200 Watt for Vehicle use CATALOG #2136.80 Cable 10 ft USB Cable CATALOG #2151.30 Lead Replacement set of (3), 10 ft (5 kV) color-coded safety with clips (Jumper lead not included) CATALOG #2151.31 Lead Replacement 1 ft jumper lead (blue) CATALOG #2151.32 Lead Set of (3), 25 ft (5 kV) safety with clips CATALOG #2960.21 Battery Rechargeable 9.6 V CATALOG #5000.14 US 115 V Power Cord CATALOG NO. 2130.30 DESCRIPTION Megohmmeter Model 5070 (Graphical, Analog Bargraph, Backlight, Alarm, Timer, 500 V, 1000 V, 2500 V, 5000 V, Step V, Auto DAR/PI/DD, USB with DataView® software) 92 www.aemc.com Technical Assistance (800) 343-1391 © Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved. Vol. 23 Rev.00 02/2023 MEGOHMMETERS 10,000 V / 15,000 V DIGITAL MODELS 6550 & 6555 Expert tools for testing insulation safely and accurately Ideal for use on rotating machinery, transformers and cables operating at higher voltages SPECIFICATIONS MODELS INSULATION TESTS Test Voltage 500 V 1000 V 2500 V 5000 V 10,000 V 15,000 V Fixed Test Voltages Variable Voltages Ramp Mode Ramp Configuration Range Step Mode Voltage Test/Safety Test Capacitance Measurement Leakage Current Measurement Discharge After Test Additional Test Stop Modes I-Limit Early-Break Timer Burn Mode Ratio Calculation Calculation of R at ref. T° Measurement Display Filter Graphs on Display Storage Communication Power Supply Battery Charging Dimensions/Weight SAFETY Safety Rating EMC/Mechanical Protection/Altitude 6550 6555 10 k to 2000 G (2 T) 10 k to 4000 G (4 T) 10 k to 10,000 G (10 T) 10 k to 15,000 G (15 T) 10 k to 25,000 G (25 T) -- 10 k to 30,000 G (30 T) (500, 1000, 2500, 5000, and (500, 1000, 2500, 5000, 10,000) V 10,000, and 15,000) V Variable: (40 to10) KV Variable: (40 to 15) KV with three user programmable with three user programmable voltage schemes voltage schemes Programmable ramps: start voltage/end voltage/duration (40 to 1100) V / (40 to 1100) V / (500 to 10,000) V (500 to 15,000) V Up to 10 steps (voltage and duration configurable for each step) 2500 VAC to 4000 VDC (0.005 to 19.99) µF (0 to 10) mA Yes/Automatic Programmable: (0.2 to 5) mA di/dt Up to 99 m 59 s Constant testing PI, DAR, DD Yes 3 filters with 3 possible time-constants R(t)+V(t); I(t); I(V) 256 registers, stores 80,000 points: R, V, I and date USB optically-isolated port NiMH rechargeable batteries, (2) 9.6 V 4 A·h battery packs charging by external voltage: (90 to 260) V; (50/60) Hz Battery charging allowed while performing insulation measurements (13.39 x 11.81 x 7.87) in (340 x 300 x 200) mm / approx. 13.7 lb (6.2 kg) 1000 V CAT IV; IEC61010-1 and IEC 61557 EN 61326-1/IP54/2000 m Consult factory for NIST Calibration prices PRODUCT INCLUDES Small classic tool bag, set of (3) 10 ft color-coded (red/blue/black) safety leads with clips (3000 V CAT III), (1) 15 kV jumper lead (blue), optical USB cable, 115 V US power cord, 9.6 V rechargeable NiMH batteries, and a USB drive with DataView® software and user manual. CATALOG NO. DESCRIPTION 2130.31 Megohmmeter Model 6550 (Graphical, Analog Bargraph, Backlight, Alarm, Timer, 500 V, 1000 V, 2500 V, 5000 V, 10 kV, Ramp, StepV, Variable, Auto DAR/PI/DD, USB, w/DataView® Software) 2130.32 Megohmmeter Model 6555 (Graphical, Analog Bargraph, Backlight, Alarm, Timer, 500 V, 1000 V, 2500 V, 5000 V, 10 kV, 15 kV, Ramp, StepV, Variable, Auto DAR/PI/DD, DataView® software) IP 54 FEATURES · True Megohmmeter® · Fixed or programmable test voltage from 40 V to 10 kV/15 kV · Wide measurement range from 10 k to 25 T/30 T · 5 mA short circuit current · Step and Ramp voltage testing · Automatic calculation of DAR / PI / DD /R (ppm/V) ratios · Large, backlit graphical LCD screen with digital display, bargraph and R(t)+V(t), I(t) and I(V) graphs · Multiple test modes: voltage ramp and step with "Burn-In", "Early-Break" and "I-Limit" modes · Three filter settings to optimize measurement stability · Calculation of R at a reference temperature · Storage of 80,000 measurements · Includes DataView® software for data retrieval, real-time display, analysis and report generation · Optically-isolated USB communication for transfer onto PC and report generation with DataView® software ACCESSORIES/REPLACEMENTS CATALOG #2133.72 Small classic tool bag CATALOG #2135.41 Optical USB cable CATALOG #2140.19 (1) 9.6 V NiMH battery (two required) CATALOG #2151.36 Lead Set of (3) color-coded (red/black/blue) 10 ft safety leads w/clips (15 kV) CATALOG #2151.37 Lead 1.5 ft blue jumper lead (15 kV) CATALOG #2151.38 Lead Set of (3), 25 ft, 15 kV color-coded (red/blue/black) safety leads w/clips CATALOG #5000.32 Power cord - 240 V EU Vol. 23 Rev.00 02/2023 Technical Assistance (800) 343-1391 © Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved. www.aemc.com 93 MEGOHMMETERS SELECTION CHART AEMC MODEL NUMBER 6503 6522 6527 6529 6526 6534 6536 6536 ESD Floor Kit 1060 6505 5050 5060 5070 6550 6555 AEMC CATALOG NUMBER TEST VOLTAGE INSULATION RANGE RESISTANCE CONTINUITY RANGE RANGE 2126.52 2155.51 2126.53 2126.55 2155.53 2155.55 2155.56 2155.57 2130.03 2130.18 2130.20 2130.21 2130.30 2130.31 2130.32 250 V (1 to 500) M 500 V (1 to 500) M 1000 V (10 to 5000) M 250 V 50 k to 10 G 500 V 100 k to 20 G 10 1000 V 200 k to 40 G 250 V 500 V 1000 V 1 k to 4 G 1 k to 4 G 1 k to 4 G 400 k 400 50 V (0.010 to 420) M 100 V (0.020 to 420) M (0 to 40) 250 V (0.050 to 420) M (0 to 420) k (200 mA test 500 V (0.100 to 4200) M current 2 ) 1000 V 0.20 M to 11 G 50 V 10 k to 10 G 100 V 250 V 500 V 20 k to 20 G 50 k to 50 G 100 k to 100 G 1000 k 10 , 100 1000 V 200 k to 200 G 10 V 2 k to 1 G 25 V 100 V 250 V 5 k to 2 G 10 k to 10 G 50 k to 25 G 1000 k 10 , 100 500 V 100 k to 50 G 10 V 100 V (variable in 2 k to 20 G 1000 k 10 , 100 1 V steps) 50 V 2 k to 200 G 100 V 4 k to 400 G 250 V 10 k to 1 T 400 k 40 500 V 20 k to 2 T 1000 V 40 k to 4 T 500 V 10 k to 2 T 1000 V 10 k to 4 T 2500 V 10 k to 10 T 5000 V 10 k to 10 T 500 V 10 k to 2 T 1000 V 10 k to 4 T 2500 V 10 k to 10 T 5000 V 10 k to 10 T 500 V 10 k to 2 T 1000 V 10 k to 4 T 2500 V 10 k to 10 T 5000 V 10 k to 10 T 500 V 10 k to 2 T 1000 V 10 k to 4 T 2500 V 10 k to 10 T 5000 V 10 k to 10 T 500 V 10 k to 2000 G 1000 V 10 k to 4000 G 2500 V 10 k to 10,000 G 5000 V 10 k to 15,000 G 10,000 V 10 k to 25,000 G 500 V 10 k to 2000 G 1000 V 10 k to 4000 G 2500 V 10 k to 10,000 G 5000 V 10 k to 15,000 G 10,000 V 10 k to 25,000 G 15,000 V 10 k to 30,000 G CAPACITANCE RANGE -- 0.1 n to 10 µF (0.005 to 4.999) µF (0.001 to 49.99) µF (0.001 to 49.99) µF (0.001 to 49.99) µF (0.001 to 49.99)µF (0.001 to 19.99) µF (0.001 to 19.99) µF Consult factory for NIST Calibration prices VOLTAGE DETECTION POWER SOURCE DISPLAY DATAVIEW® SOFTWARE 600 VAC Hand-cranked Analog No 700 VAC/DC (6) AA Alkaline Digital/ Batteries Analog No 600 VAC 1000 VDC (6) AA Alkaline Digital/ Batteries Analog No 700 VAC 700 VAC/DC (6) AA Alkaline Batteries Digital No 700 VAC/DC (6) AA Alkaline Digital/ Batteries Analog Yes 700 VAC/DC (6) AA Alkaline Digital/ Batteries Analog Yes 700 VAC/DC (6) AA Alkaline Digital/ Batteries Analog No 1000 VAC/DC Rechargeable NiMH Battery Digital/ Analog Yes 2500 VAC 4000 VDC Rechargeable NiMH Battery Digital/ Analog No 2500 VAC 4000 VDC Rechargeable NiMH Battery Digital/ Analog No 2500 VAC 4000 VDC Rechargeable NiMH Battery Digital/ Analog Yes 2500 VAC 4000 VDC Rechargeable NiMH Battery Graphic/ Digital Yes 2500 VAC 4000 VDC Rechargeable NiMH Battery Digital/ Analog Yes 2500 VAC 4000 VDC Rechargeable NiMH Battery Digital/ Analog Yes 94 www.aemc.com Technical Assistance (800) 343-1391 © Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved. Vol. 23 Rev.00 02/2023 MICRO-OHMMETERS DATA ANALYSIS AND REPORTING SOFTWARE SEE PAGE 133 FOR MORE INFO ON DATAVIEW® SOFTWARE CONFIGURE MICRO-OHMMETER MODELS 6240, 6255 & 6292 Customize views and templates / Configure test options / Display and print reports of all test results / Retrieve data from the instrument's memory SEE WEBSITE FOR PRICING AND AVAILABILITY: WWW.AEMC.COM MICRO-OHMMETERS 10 A MODEL 6240 Auto calculates resistance from 5 µ to 400 with resolutions down to 1 µ SPECIFICATIONS MODEL Range Accuracy Resolution Test Current Max. Inductive Load Memory Power Supply (5.0 to 3999) µ 1 µ 10.2 A ± 2 % 6240 (4.0 to (40.0 to (400 to (4.0 to (40.0 to 39.99) m 399.9) m 3999) m 39.99) 399.9) ± 0.25 % of Reading ± 2 cts 10 µ 100 µ 1 m 10 m 100 m 1.02 A ± 2 % 102 mA ± 2 % 10.2 mA ± 2 % 0.5 H Stores up to 99 test results Rechargeable 6 V, 8.5 A·h NiMH battery pack (included) Consult factory for NIST Calibration prices ACCESSORIES/REPLACEMENTS CATALOG #1017.84 (Replacement) Kelvin Clips 10 ft (10 A - Hippo) CATALOG #2118.70 Kelvin Clips 20 ft (10 A - Hippo) CATALOG #2118.73 (Replacement) Kelvin Probes 10 ft (1 A, Spring Loaded) CATALOG #2118.74 Kelvin Probes 20 ft (1 A, Spring Loaded) CATALOG #2118.84 Kelvin Probes Pistol Grip 10 ft (25 A, Spring Loaded) CATALOG #2118.85 Kelvin Probes Pistol Grip 20 ft (25 A, Spring Loaded) CATALOG #2118.77 Kelvin Probes 10 ft (10 A, Spring Loaded) CATALOG #2118.78 Kelvin Probes 20 ft (10 A, Spring Loaded) CATALOG #2118.79 Kelvin Clips 10 ft (1-10 A) Replacement for Cat. #2118.71 CATALOG #2118.80 Kelvin Clips 20 ft (1-10 A) Replacement for Cat. #2118.72 PRODUCT INCLUDES Extra large tool bag, set of (2) 10 ft Kelvin clips (10 A - Hippo), set of (2) 10 ft Kelvin probes (1 A - Spring Loaded), optical USB cable, US 115 V power cord, (2) spare fuses (12.5 A), NiMH 6 V rechargeable battery pack*, and USB drive with DataView® software and user manual. *Can be charged during operation IP IP 64 53 cover closed cover open FEATURES · Reliable low resistance measurements from 5 µ to 400 · Four-terminal Kelvin resistance measurement eliminates test lead resistance · 10 A test current up to 4000 µ · ± 0.25 % basic accuracy · 1 µ resolution · Direct reading, easy to operate · Six selectable resistance ranges · Reverse polarity button · Overload and input fuse protection · Manufactured to international safety and environmental standards · Automatic decimal point and zeroing · Large terminals accept banana plugs and spaded lugs · Rechargeable NiMH battery with internal charger (110/220 V). Can be charged during operation · Large multifunctional backlit display · Includes power cord and isolated USB cable · Includes DataView® software for data retrieval, real-time display, analysis and report generation CATALOG NO. 2129.80 DESCRIPTION Micro-Ohmmeter Model 6240 (10 A, Instantaneous, Continuous, Multiple Test, includes 10 ft Kelvin Clips (10 A - Hippo-Cat #1017.84), 10 ft Kelvin Probes (1 A Spring Loaded, Cat #2118.73) and DataView® Software) 96 www.aemc.com Technical Assistance (800) 343-1391 © Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved. Vol. 23 Rev.00 02/2023 MICRO-OHMMETERS 10 A MODEL 6255 Accurate results within 0.05 % Provides extended test time at 10 Amps without overheating SPECIFICATIONS IP 64 cover closed MODEL Range Accuracy Resolution Test Current Measurement Mode Metal Type Alpha Alarms Memory Power Supply Battery Life 6255 5.0000 25.000 250.00 2500.0 25.000 250.00 2500.0 m m m m ± 0.15 % of Reading +1.0 µ ± 0.05 % of Reading + 3 µ ± 0.05 ± 0.05 % of % of Reading Reading + 30 µ + 0.3 m ± 0.05 % of Reading + 3 m ± 0.05 ± 0.05 % of % of Reading Reading + 30 m + 300 m 0.1 µ 1 µ 10 µ 0.1 m 1 m 10 m 100 m 10 A 1 A 100 mA 10 mA 1 mA Selectable: Inductive (continuous test), Resistive (instantaneous test) or Auto (multiple tests) Selectable: copper, aluminum or other metal Programmable from 000.00 to 99.99 Two programmable set points from (0.0 to 2500.0) Stores up to 1500 test results; data in memory can be reviewed on the instrument display, on a PC or via direct printout Rechargeable 6 V, 8.5 A·h NiMH battery pack (included) Approximately 5000 10 A tests IP 53 cover open FEATURES · Measure from 1 µ (0.1 µ resolution) to 2500.0 · Test current selection of (1, 10, and 100) mA, and (1 and 10) A · RTD temperature probe to check tested sample (optional) · Selectable metal types · Automatic and manual temperature correction Consult factory for NIST Calibration prices · Two programmable alarm set points ACCESSORIES/REPLACEMENTS CATALOG #1017.84 Kelvin Clips 10 ft (10 A - Hippo) CATALOG #2118.70 Kelvin Clips 20 ft (10 A - Hippo) CATALOG #2118.73 Kelvin Probes 10 ft (1 A, Spring Loaded) CATALOG #2118.74 Kelvin Probes 20 ft (1 A, Spring Loaded) CATALOG #2118.84 Kelvin Probes Pistol Grip 10 ft (25 A, Spring Loaded) CATALOG #2118.85 Kelvin Probes Pistol Grip 20 ft (25 A, Spring Loaded) CATALOG #2118.77 Kelvin Probes 10 ft (10 A, Spring Loaded) CATALOG #2118.78 Kelvin Probes 20 ft (10 A, Spring Loaded) CATALOG #2118.79 Kelvin Clips 10 ft (1-10 A) / Replacement for Cat. #2118.71 CATALOG #2118.80 Kelvin Clips 20 ft (1-10 A) / Replacement for Cat. #2118.72 CATALOG #2119.45 Cable, PC RS-232, DB9 F/F 6 ft Null Modem Cable CATALOG #2129.95 RTD Temperature Probe (plug into faceplate for ambient temperature) CATALOG #2129.96 RTD Temperature Probe with 7 ft extension cable · Stores up to 1500 test results · Selectable inductive or resistive test modes · Automatic multiple test mode (multiple tests without pressing the test button) · Large multi-line electroluminescent display · Local or remote test setup and control · Internal rechargeable batteries conduct up to 5000 10 A tests · Rugged, double insulated watertight case · Includes FREE DataView® software for data retrieval, real-time display, analysis and report generation PRODUCT INCLUDES Extra large tool bag, set of (2) 10 ft Kelvin Clips (10 A - Hippo), set of (2) 10 ft Kelvin Probes (1 A - Spring Loaded), RS-232 DB9 F/F 6 ft null modem cable, RS-232 to USB adapter, US 115 V power cord, NiMH rechargeable 6 V battery pack (installed in meter), quick start guide and a USB drive with DataView® software and user manual. SHOWN: CAT. #2129.84 CATALOG NO. DESCRIPTION 2129.84 Micro-Ohmmeter Model 6255 (10 A, Instantaneous, Continuous, Multiple Test, Manual/Auto Temperature Compensation; includes 10 ft Kelvin Clips (10 A-Hippo, Cat #1017.84), 10 ft Kelvin Probes (1 A Spring Loaded, Cat #2118.73) and DataView® Software) Vol. 23 Rev.00 02/2023 Technical Assistance (800) 343-1391 © Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved. www.aemc.com 97 MICRO-OHMMETERS 200 A MODEL 6292 Programmable test currents and test duration with data storage and report generation using included application software Includes both sides grounded test feature Case color may vary SPECIFICATIONS MODEL 6292 Electrical Test Current Range Adjustable from (5 to 200) A (True DC) Resistance Range 0.1 µ to 2 m (2 to 200) m 200 m to 1 Accuracy ± 1 % of reading from 50 µ to 1 Resolution 0.1 µ to 2 m 2 m to 200 m 200 m to 1 0.1 µ (5 to 200) A 10 µ (25 A @ 200 m) 1 m (5 A @ 1 ) Output Voltage 100 VAC: 4.2 V @ 200 A 220 VAC: 8.6 V @ 200 A Max. Load Resistance 100 VAC: 20 m @ 200 A 220 VAC: 42 m @ 200 A Measurement Method Four-terminal, Kelvin-type Adjustable Test Time 5 to 120 s or unlimited Memory Stores up to 8000 measurements Power Supply (100 to 240) VAC, (50/60) Hz Consult factory for NIST Calibration prices ACCESSORIES/REPLACEMENTS CATALOG #2129.86 Current Probe MR6292 CATALOG #2129.72 Lead - Set of (2) 25 ft Kelvin clips (200 A - Hippo) CATALOG #2129.73 Lead - Set of (2) 50 ft Kelvin clips (200 A - Hippo) CATALOG #2129.88 Lead - 10 ft Earth/Ground (Green) with attached Clamp CATALOG #5000.40 110 V US Power Cord PROBE MR6292 IP 54 cover closed FEATURES · Adjustable test currents from (5 to 200) A · Programmable test duration from (5 to 120) seconds · BSG Ground Test with optional current probe · Incorporates True DC high output with minimum, near zero, ripple lower than 2 % of full range · Accurately measures low contact resistance with test currents up to 200 A · Measures resistances from 0.1 µ to 1 · Low resolution of 0.1 µ · Cooling system to improve the number of sequential tests that can be performed · Backlit display · Measures objects with both sides grounded · Stores up to 8000 test results · Direct printout of measurement results using DataView® software and a PC · Rugged and water-resistant case PRODUCT INCLUDES Extra large tool bag, set of (2) 25 ft Kelvin clips (200 A - Hippo), (1) ground lead (green) with clamp, 5 ft USB cable, 110 V US power cord, printed quick start guide and a USB thumb drive with DataView® software and user manual. FRONT PANEL DISPLAY Test Results Test Current Date & Time ò ñððþðð ðIôtòõòñññððôòðññÿþú ðñðIñõùúòõðøðöðþðñðñýs Ground Current Elapsed and Total Test Times CATALOG NO. DESCRIPTION 2129.83 Micro-Ohmmeter Model 6292 (200 A, 120 V/230 V, DataView® Software) 98 www.aemc.com Technical Assistance (800) 343-1391 © Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved. Vol. 23 Rev.00 02/2023 OSCILLOSCOPESREMOVE 5022 ADD KIT ADD CAT# LINE AT BOTTOM SEE WEBSITE FOR PRICING AND AVAILABILITY: WWW.AEMC.COM OSCILLOSCOPES HANDSCOPE MODEL OX 5042B 3-in-1 Instrument: Oscilloscope, Multimeter and Power Harmonic Analyzer with two fully isolated channels; fits into one hand SPECIFICATIONS INTERFACE Display Commands Display Mode Display of Curves on Screen Integrated Interactive Help Function OSCILLOSCOPE MODE Vertical Deflection Bandwidth Bandwidth Limiter Number of Channels Input Impedance Maximum Input Voltage Vertical Sensitivity Horizontal Deflection Sweep Speed Horizontal Zoom Triggering Mode Type Coupling Sensitive Digital Memory Maximum Sampling Rate Vertical Resolution Memory Depth User Storage GLITCH Mode Display Modes Other Functions Math Functions Cursor Measurement Automatic Measurement Multimode Mode General Specifications Operating Modes AC, DC & AC+DC Voltages Resistance Capacitance Other Measurements POWER Measurements Harmonic Analyzer Mode Multi-Channel Analysis Simultaneous Measurements GENERAL Screenshots PC Communication Power Supply Safety/EMC 3.5 in color TFT LCD screen; Resolution (320 x 240) pixels LED backlighting Direct adjustments on front panel & on-screen menus via browser (principal & secondary without "hidden menus") 2500 real acquisition points on screen 2 curves + 2 references + memory trace or mathematical calculation 14 complete languages, menus and online help IP 54 3 YEAR WARRANTY 40 MHz 1.5 MHz, 5 kHz 2 fully isolated channels 1 M ± 0.5 %, approx. 17 pF 600 V Derating -20 dB per decade from 100 kHz 5 mV to 200 V/div 25 ns/div to 200 s/div Roll Mode from 100 ms to 200 s/div Zoom factor: x1, x2, x5 Automatic, triggered, one-shot & triggered roll Edge, pulse width (20 ns 20 s) AC or DC (depending on the coupling of the triggering channel) HF, LF or noise rejection 1.2 divisions p-p up to 40 MHz 2 Gs/s in ETS mode 50 MS/s in one-shot mode on each channel 9 bits 2500 points per channel 2 MB for storing files: trace (.trc), text (.txt), configuration (.cfg), image files (.bmp) Duration 20 ns 1250 min / max pairs Envelope, Averaging (factors 2 to 64) and XY (vector) Channel inversion, addition, subtraction, multiplication and division (adjustable scaling) 2 cursors: V, T, dV, dt simultaneously 4-digit display resolution 18 time or level measurements and phase measurement 2 channels, 8000-count display + min / max bargraph Graphic recording of 2700 measurements (5 min to 1 mos) Absolute or relative display (absolute, deviation, ref, ref %) Monitoring (instantaneous, min, max, avg) Ranges from 600 mV to 600 Vrms, 800 mV to 800 VDC accuracy for VDC ± 1 % reading +20 D 50 kHz bandwidth Range from 80 to 32 M - accuracy ± 2 % reading + 10 D 10 ms quick continuity test Ranges from 5 nF to 5 mF basic accuracy ± 2 % reading + 10 D Frequency, rotation speed, 3.3 V diode test, temperature measurement (with K-type thermocouple or infrared probe) Single-phase and balanced three-phase active power values (with or without neutral), simultaneous display of current 2 channels, 31 orders, fundamental frequency from (40 to 450) Hz Total VRMS, THD and selected order (% fundamental, phase, frequency, Vrms) Up to 100 files in standard .bmp format, viewable on the instrument Isolated optical USB interface SX-Metro PC application software (included) 6 LR6 or (6) AA NiMH batteries Battery life up to 8 h 30 min Universal line adapter isolated from the channels Quick charging in 2 h 30 min Safety according to IEC61010-1 600 V CAT III / EMC according to EN61000-3 & EN61326-1 Consult factory for NIST Calibration prices 100 www.aemc.com Technical Assistance (800) 343-1391 © Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved. Vol. 23 Rev.00 02/2023 OSCILLOSCOPES HANDSCOPE FUNCTIONAL DISPLAYS FEATURES · Two fully isolated channels · Three instruments in one - 40 MHz Oscilloscope - Double 8000-count TRMS Multimeter / Power Analyzer - Harmonic Analyzer · 3.5 in color LCD screen LED backlighting technology · Integrated interactive multilingual help function · 2 MB recording data · Store graphic recordings of 2700 measurements (5 min to 1 mos) · Communication via isolated USB SCPI protocol HIGH PERFORMANCE HARMONIC ANALYZER Automatically displays measurements for both isolated channels from your choice of 19 measurement types TWO INDEPENDENT 8000-COUNT TRMS DIGITAL MULTIMETERS Measures two channels of individual harmonic content up to the 31st harmonic STORAGE COMMUNICATION & PC SOFTWARE PRODUCT INCLUDES 2150.21 Meter, small classic tool bag, US wall plug, USB cable, set of (2) 10 ft color-coded (red/black) leads, set of (2) color-coded (red/black) alligator clips, set of (2) color-coded (red/black) probes, BNC adapter, (2) probes 10:1 600 V BNC male, (6) 1.2 V NiMH rechargeable batteries, printed quick start guide, and a USB drive with software and user manual. 2150.22 Meter, field case, US wall plug, USB cable, set of (2) 10 ft color-coded (red/black) leads, set of (2) color-coded (red/black) alligator clips, set of (2) color-coded (red/black) probes, BNC adapter, (1) probe 10:1 600 V BNC male, (1) AC current probe Model MN251T, MiniFlex® Sensor 3000-24-1-1, (6) 1.2 V NiMH rechargeable batteries, printed quick start guide, and a USB drive with software and user manual. View real-time measurements on your PC, configure the Handscope, export data to spreadsheet using the SX-Metro included software Instantly displays measurements in multimeter mode at the press of a button 2150.23 Meter, field case, US wall plug, USB cable, set of (2) 10 ft color-coded (red/black) leads, set of (2) color-coded (red/black) alligator clips, set of (2) color-coded (red/black) probes, BNC adapter, (1) probe 10:1 600 V BNC male, (1) AC current probe Model MN379T, MiniFlex® Sensor 3000-24-1-1, (6) 1.2 V NiMH rechargeable batteries, printed quick start guide, and a USB drive with software and user manual. SHOWN: CATALOG #2150.22 CATALOG NO. 2150.21 2150.22 2150.23 DESCRIPTION Handheld Portable Oscilloscope Model OX 5042B Handheld Portable Oscilloscope Model OX 5042B w / MN251T & MF 3000-24-1-1 (BNC Output) Handheld Portable Oscilloscope Model OX 5042B w / MN379T & MF 3000-24-1-1 (BNC Output; Low AC current measurement) Vol. 23 Rev.00 02/2023 Technical Assistance (800) 343-1391 © Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved. www.aemc.com 101 OSCILLOSCOPES CURRENT PROBES MODELS MN251T & MN379T SPECIFICATIONS ELECTRICAL Nominal Range Measurement Range Accuracy Phase Shift Overload Frequency Range Limit Operating Conditions Working/Common Mode Voltage Output Termination Output Signal MECHANICAL Operating Temperature Storage Temperature Operating Relative Humidity Jaw Opening Maximum Conductor Size Dimensions Weight Polycarbonate Material SAFETY Safety Rating MN251T MN379T 200 A 5 A / 100 A (0.5 to 240) A (0.005 to 6) A; (0.1 to 120) A 3 % of Reading @ 5 A; 1 % of Reading @ 200 A 1 % of Reading @ 5 A; 1 % of Reading @ 100 A 2.5 ° @ 20 A / 2.5 ° @ 100 A 4 ° @ 5 A / 2.2 @ 100 A 240 A for 10 min ON, 30 min OFF (40 to 10) kHz 200 A permanently to 1 kHz; Derating above 3 kHz: 200 A x (1/0.333 F), F in kHz 600 Vrms 10 ft (~3 m) BNC Lead 1 mV/AAC (200 mV @ 200 A) 200 mV/AAC (1 V @ 5 A) & 10 mV/AAC (1 V @ 100 A) (14 to 131) °F (-10 to 55) °C (-40 to 158) °F (-40 to 70) °C (10 to 35) °C (50 to 95) °F 85 % RH (without roll-off above 35 °C (95 °F)) 0.83 in (21 mm) 0.78 in (20 mm) (5.47 x 2.00 x 1.18) in (139 x 51 x 30) mm 6.5 oz (184 g) Polycarbonate with fiberglass charge, UL94 V0 EN 61010-2-32 Consult factory for NIST Calibration prices MINIFLEX® 3000-24-1-1 SPECIFICATIONS 3000-24-1-1 ELECTRICAL Range (5 to 3000) A Signal Output 1 mV/A Frequency Range 10 Hz to 20 kHz with current derating Influence Of Conductor Positioning 1.5 % typical, 3 % max Influence Of Conductor Positioning In Sensor Against Handle 4 % typical, 6 % max External Conductor Influence (35 to 40) dB on contact Power Supply 9 V Alkaline battery (included) MECHANICAL Sensor Diameter Ø 0.2 (5 mm) Sensor Length 14 in (~355 mm) 24 in (~609 mm) Max Conductor Size 3.93 in (~100 mm) 7.6 in (~190 mm) Connection Cable Length 10 ft (~3.04 M) Drop Test Per IEC 68-2-32 Vibration Per IEC 68-2-6 Mechanical Shock Per IEC 68-2-27 Weatherproofing IP50 ENVIRONMENTAL Operating Temperature Range (14 to 131) °F (-10 to 55) °C Storage Temperature Range (-40 to 158) °F (-40 to 70) °C Altitude Operating: (0 to 6560) ft (2000 m), working voltage derating above; Non-operating: (0 to 39,370) ft (12,000 m) SAFETY Safety Rating EN 61010, 1000 V CAT III; 600 V CAT IV Consult factory for NIST Calibration prices CATALOG #2132.59 Range (0.05 to 240) A CATALOG #2153.02 Range (0.005 to 120) A FEATURES · Small, compact size · True RMS measurements · Large jaw opening accommodates conductor sizes up to 250 MCM · 10 foot leads make measurements in hard to reach areas possible · 40 Hz to 10 kHz response SAFETY R ATIN G 3000-24-1-1 only CATALOG #2132.63 (24 IN) FEATURES · True RMS Measurements · 24 in (~60 cm) sensor optional · 10 ft (~3 m) leads makes measure- ment in hard to reach areas possible · Measurement range of (0.5 to 3000) Arms · Accuracy ± 1 % of Reading ± 0.25 A · No core saturation or damage if measured circuit is overloaded · 20 kHz frequency response · Low phase shift for power measurements · Insensitive to DC: measures only the AC component on DC+AC signals · Excellent linearity · 9 V Alkaline battery typically offers 150 h of continuous operation 102 www.aemc.com Technical Assistance (800) 343-1391 © Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved. Vol. 23 Rev.00 02/2023 OSCILLOSCOPES OX 9000 SERIES MODELS OX 9062, OX 9102, OX 9104 & OX 9304 Ergonomic, hand-held oscilloscope with 100 MHz bandwidth and 4 models: oscilloscope, multimeter, analyzer and recorder OSCILLOSCOPE OX 9104 HARMONICS FEATURES · Wider bandwidth up to 300 MHz (model dependent) · Advanced triggering and recording options · Increased storage capacity, and more! · 12-bit resolution · 2.5 Gs/s OX 9062 MULTIMETER - DISPLAYS UP TO 4 CHANNELS SIMULTANEOUSLY PRODUCT INCLUDES Scope in carrying case with shoulder strap, set of (2) 5 ft color-coded leads, alligator clips and test probes (4 mm diameter), 10 ft USB cable, µSD memory card, 1-PROBIX Banana Plug (4 mm) adapter, (1) stylus pen, LI-ION 5.8 A·h battery pack, PA40W-2 power adapter with 110 V power cord. Additional accessories (model dependent). MEASUREMENT BETWEEN H AND V CURSORS: T1, T2, DT, 1/DT, V1, V2, DV, PH ACCESSORIES/REPLACEMENTS 5000.17 Set of 5 stylus pens CATALOG NO. 2150.31 2150.32 2150.33 2150.34 DESCRIPTION Handheld Portable Oscilloscope Model OX 9062 IV 60 MHz (2-Channel, 60 MHz) -- SPECIAL ORDER ONLY Handheld Portable Oscilloscope Model OX 9102 IV 100 MHz (2-Channel, 100 MHz) -- SPECIAL ORDER ONLY Handheld Portable Oscilloscope Model OX 9104 IV 100 MHz (4-Channel, 100 MHz) Handheld Portable Oscilloscope Model OX 9304 IV 300 MHz (4-Channel, 300 MHz) Vol. 23 Rev.00 02/2023 Technical Assistance (800) 343-1391 © Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved. www.aemc.com 103 OSCILLOSCOPES OX 9000 SERIES ERGONOMICS Designed to simplify use with one button access to most functions In a housing tailor-made to be as compact as possible, the mechanical design makes it possible to integrate the hardware components in a small size with the keypad benefits from new technology developed in the automotive industry. ISOLATED CHANNELS Each channel is isolated from each other and from ground (earth) rated at 600 V CAT III. CHANNEL AND PARAMETER IDENTIFICATION Each channel and related parameters are identified with identical color against a black background for simpler, quicker viewing. EASY ACCESS VIA TOUCH SCREEN Intuitive icons are provided to facilitate their use, even with gloves on. ADJUSTABLE STRAP This helps to optimize operation of the oscilloscope in your hand or on your shoulder when working in the field. A stand is also available to vary the orientation of the oscilloscope when it is placed on a bench. The oscilloscope can be safely left unattended using the Kensington locking system. NEW KEYPAD DESIGN FOR OPTIMUM USER COMFORT Configuration and measurement displays are simple to access from the front panel in one of these 5 specific areas: Utilities (brightness, full screen, screenshot), Measurements, Vertical, Horizontal, Trigger. LINE POWER AND LI-ION BATTERY CHARGING PORT Port on left side. IP 54 Rated Original ETHERNET 104 www.aemc.com Technical Assistance (800) 343-1391 © Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved. Vol. 23 Rev.00 02/2023 OSCILLOSCOPES OX 9000 SERIES APPLICATIONS Ideal for electronic and industrial maintenance IP54 Housing protected against dust and water spray. 7-INCH WVGA WIDE COLOR TFT TOUCH SCREEN Makes it easy to view and read the measurements clearly. It also provides a screen resolution of (800 x 480) dpi with manual or automatic brightness. TOUCH-SCREEN STYLUS STORAGE Among the essential tools available, the stylus is equipped with a hook for the addition of a cord to make it captive, as required. One end is slightly flattened to prevent rolling when placed on a table or bench. AUTOSET BUTTON Quickly and effortlessly adjusts the horizontal and vertical; sensitivity and scales to provide the best resolution. DIRECT SETTING AND SETUP BUTTONS COMMUNICATION INTERFACES These are isolated from one another and from the measurement channels. A dedicated compartment on the right side protected by a flexible cover contains all the different communication interface ports: " USB host for communication with a PC " Wired RJ45 or WiFi for communication with a PC or printing via a network printer " µSD card for data storage with quick transfer and for upgrading of the instrument's firmware DIRECT ACCESS ZOOM BUTTON Activates/deactivates the horizontal Zoom function ELECTRONIC MAINTENANCE The OX 9304 model is ideal for electronics with its 300 MHz bandwidth, (4) 600 V CAT III isolated channels, advanced trigger functions, integrated FFT function, complex mathematical calculations on the curves, automatic measurements on 4 channels and the built-in WEB server. INDUSTRIAL MAINTENANCE The OX 9304's large 7-inch screen, 300 MHz bandwidth, (4) 600 V CAT III isolated channels and Harmonic Analyzer and Multimeter modes make it ideal for industrial maintenance applications. Vol. 23 Rev.00 02/2023 Technical Assistance (800) 343-1391 © Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved. www.aemc.com 105 OSCILLOSCOPES OX 9000 SERIES TECHNICAL SPECIFICATIONS OX 9062 OX 9102 OX 9104 OX 9304 HUMAN-MACHINE INTERFACE Type of Display 7 in WVGA color TFT LCD touch screen, (800 x 480) dpi LED backlighting (adjustable standby mode) Different Display Mode 2,500 real acquisition points on screen - vectors with interpolation Display of Curves on Screen 4 curves + 4 references split screen & full screen modes Screen Commands Touch screen icons and graphical commands customizable channel colors Choice of Language 15 complete languages, menus and online help OSCILLOSCOPE MODE Vertical Deflection Bandwidth 60 MHz 100 MHz 100 MHz 15 MHz, 1.5 MHz or 5 kHz bandwidth limiter 300 MHz Number of Channels 2 isolated channels 4 isolated channels Input Impedance 1 M ± 0.5 %, approx. 12 pF Maximum Input Voltage 600 V CAT III (1,000 V per Probix) from (50 to 400) Hz Probix safety connectors Vertical Sensitivity 16 ranges from 2.5 mV to 200 V/div and up to 156 µV/div in vertical zoom mode (12-bit converter) Accuracy ± 2 % Vertical Zoom 'One click Winzoom' mode (12-bit converter and direct graphical zoom on screen) x 16 max. Probe Factor (non-Probix) 1 / 10 / 100 / 1,000 or any scaling definition of measurement unit Horizontal Deflection Sweep Speed 35 ranges from 1 ns/div to 200 s/div., accuracy ± [50 ppm + 500 ps] Roll mode from 100 ms to 200 s/div Horizontal Zoom 'One click Winzoom' system (direct graphical zoom on screen) x 1 to x 5 or x 100 storage 100 kpts/channel Triggering Mode On all the channels: automatic, triggered, one-shot, auto level 50 % Type Edge, pulse width (16 ns-20 s), Delay (48 ns to 20 s), Counting (3 to 16,384) events. Continuous adjustment of trigger position. Coupling AC, DC GND, HFR, LFR, noise Level and Hold-off adjustable from 64 ns to 15 s Sensitivity 1.2 division p-p up to 300 MHz Digital Storage Maximum Sampling Rate 2.5 Gs/s in one-shot mode on each channel (100 Gs/s max. in ETS mode) Vertical Resolution 12 bits (vertical resolution 0.025 %) Memory Depth User Storage / File Management GLITCH Mode 100 kpts per channel and file viewer in the manager Internal = 1 GB to store the files: trace, text, configuration, math functions, system memory / PDF print files, PNG image files + high-capacity removable µSD card: SD 2 GB, SDHC (4 to 32) GB and SDXC > 32 GB Duration 2 ns 500,000 min/max pairs Display Modes Envelope, vector, accumulation-, averaging (factors 2 to 64) XY (vector) and Y(f) = FFT Other Functions AUTOSET Complete in under 5 s, with recognition of the channels Frequency > 30 Hz FFT Analyzer & MATH Functions 2,500-point FFT (Lin or Log) with measurement cursors Functions +, -, x / and mathematical function editor Cursors 2 or 3 cursors: simultaneous V and T with AUTO measurement: T1, T2, Dt, 1/Dt, dBV, Ph Automatic Measurements Simultaneously with waveform, 20 automatic measurements per channel and on the 4 channels simultaneously with scroll MULTIMETER MODE General Specifications 2 or 4 channels 8,000 cts min/max/frequency/relative TRMS Time/date-stamped graphical recording in logger mode AC, DC and AC + DC Voltages 600 mV to 600 VRMS, 800 mV to 800 VDC VDC accuracy +/- (0.5 % + 25 D) 200 kHz bandwidth Resistance 80 to 32 M accuracy 0.5 %R+ 25 D quick continuity test < 10 ms Other Measurements Temperature (HX0035 = KTC, HX0036 = Pt100) / Capacitance 5 nF to 5 mF / Frequency 200 kHz / Diode test 3.3 V Single and Three-Phase Power Active, Reactive and Apparent power values plus Power Factor simultaneously with the U & I measurements Harmonic Analyzer Mode Multi-channel Analysis 2 or 4 (depending on model), 63 orders, fundamental frequency (40 to 450) Hz in auto or manual mode Simultaneous Measurements Total Vrms, THD and selected order (% fundamental, phase, frequency, Vrms) Logger Mode Acquisition Duration: 20,000 s Interval: 0.2 s Files: 100,000 measurements GENERAL Configuration Memories Not limited according to device - variable file sizes Printing Network printing via Ethernet/Wifi in .png format PC Communication Software Software Mains Power Supply Safety / EMC / IP Protection Ethernet (100 baseT), Wi-Fi-USB (device, 12 Mbps) ScopeNet application software for PC PC: Ethernet and USB, ScopeNet (remote control, data recovery, cursors and automatic measurements) AndroidTM tablet ScopeAdmin Fleet Administration utility Li-ion rechargeable battery (6,900 mA·h-40 W·h) Battery life of up to 8 h Adjustable standby mode Adapter / 2-hour fast charger, universal (98 to 264) V / (50/60) Hz) Safety as per IEC 61010-2-30, 600 V CAT III, 1000 V CAT II / EMC as per EN61326-1 / IP54 protection Mechanical Specifications (11.52 x 8.29 x 2.60) in (293 x 211 x 66) mm / 4.6 lbs (2.1 kg) with batteries 106 www.aemc.com Technical Assistance (800) 343-1391 © Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved. Vol. 23 Rev.00 02/2023 APNOAWLYEZREQRUS,AMLIETTYE/RESN&ERLGOYGGERS DATA ANALYSIS AND REPORTING SOFTWARE SEE PAGE 133 FOR MORE INFO ON DATAVIEW® SOFTWARE CONFIGURE POWER QUALITY / ENERGY ANALYZERS, METERS & LOGGERS MODELS PEL 52, 102, 103 & 105, POWERPAD® III 8333, 8336, 8436, POWERPAD® IV 8345 Configure functions and parameters from your PC / Customize views, templates and reports / Create and store a complete library of configurations and test options / Display waveforms, trend graphs, harmonic spectrums, text summaries, transients, event logs and stored alarms / Display and print reports of all test results / Retrieve data from the instrument's memory SEE WEBSITE FOR PRICING AND AVAILABILITY: WWW.AEMC.COM POWER QUALITY / ENERGY ANALYZERS, METERS & LOGGERS PowerPad® IV Model 8345 NEW The PowerPad ® moves up a grade - Class A! SPECIFICATIONS A POWERP D IV Class MODEL ELECTRICAL Inputs Voltage Harmonics Mode Interharmonics Mode Inrush & Transient Capture (number) Shockwaves (Fast transient) Flicker (Pst) Voltage Unbalance (u0,u2) Trend Recording 8345 5 x voltage / 4 x current, isolated (5 to 1,000) VAC and VDC DC to 63rd order 0 to 62nd order No maximum (limited by SD card) Up to 12 kV sampled every 500 ns < 0.1 (0.5 to 5) % (absolute); ± 0.15 % (absolute) > 900 parameters 3 d with a sampling period of 200 ms 15 d with a sampling period of 1 s 45 d with a sampling period of 3 s Sampling Rate Alarm Mode (types / number) Real-time / Power / Energy / Unbalance Modes Screenshots Voltage 400 kSps / Current 200 kSps / Surge 2 MSps 52 / 20,000 with Email notifications Yes / Yes / Yes / Composite No maximum (limited by SD card) Power Supply Carrier Current Detection Power from phase from (100 to 1000) V AC/DC with external supply block (included) Yes Battery Life MECHANICAL Cartridge Li-ion 5800 A·h battery pack (included) 6 h w/ display ON; 10 h w/ display OFF Data Storage 16 GB SD-Card (included) for snapshot, transients, alarms and trend recording Display Clock / GPS Operating Temperature 7 in color LCD touch screen: 800 x 480 (WVGA) Yes, built-in (32 to 104) °F (0 to 40) °C Communication USB, Ethernet, Wi-Fi, Web server, IRD server, USB stick port (Type A) Dimensions (7.87 x 11.22 x 2.17) in (200 x 285 x 55) mm Weight (meter only) 4.19 lb (1.9 kg) COMPLIANCE & STANDARDS Safety IEC 61010 1000 V CAT IV Environmental IEC 61557-12 & IEC 62586 Measurement Standard IEC 61000-4-30 (Ed 3) Class A (Full) EN50160 Monitoring Mode With PAT3 software Warranty *3 y (registration must be done within 30 d of the date of purchase) Consult factory for NIST Calibration prices CATALOG NO. DESCRIPTION 2136.35 PowerPad® IV Model 8345 (no probes) 2136.36 PowerPad® IV Model 8345 w/4 194-24-BK MiniFlex® Sensors * UPON REGISTERI TM ETHERNET WEB SERVER IP 54 PRODUCT INCLUDES CAT. # 2136.35 - POWERPAD IV MODEL 8345 (NO PROBES) CAT. # 2136.36 - POWERPAD IV MODEL 8345 (WITH (4) MINIFLEX® MA194-24-BK FLEXIBLE CURRENT SENSORS ) Extra large tool bag, internal carrying pouch, hand strap, USB cable, (5) 10 ft black voltage leads with alligator clips, (12) color-coded input ID markers, power adapter (PA32ER) with US power cord, (2) 6 ft stackable leads, (2) 10 ft black voltage leads with alligator clips for power adapter PA32ER, (1) power plug adaptor for PA32ER, 5.8 A·h Li-ion battery pack, quick start guide, and a USB stick with DataView® software and user manual. (4) MINIFLEX® MA194-24-BK FLEXIBLE CURRENT SENSORS (WITH CAT.# 2136.36) NG 108 www.aemc.com Technical Assistance (800) 343-1391 © Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved. Vol. 23 Rev.00 02/2023 POWER QUALITY/ENERGY ANALYZERS, METERS & LOGGERS FEATURES FEATURES Large Functional Displays · Full compliance with IEC 61000-4-30 ed. 3.0 Class A functions · Voltage quality diagnostics ENERGY EVALUATION TREND · Real-time display of color waveforms (5 voltage/4 current) from 1 cycle to 10/12 cycles · Calculation of unbalance (current and voltage) · Automatic recognition of different current sensors · Capture shockwaves up to 12 kV with a resoluton of 500 ns · Trend recording period from 200 ms to 2 h · RMS and Peak InRush for up to 30 min · Display of phasor diagrams SHOCKWAVES ALARMS · Waveforms at 512 samples per cycle, with Min/Max 2.5 s · True InRush capabilities to study loads during setup · Parameterization with software for True RMS single-, twoand three-phase measurements at 512 samples/cycle, plus DC · Records and stores hundreds of parameters in memory every 10/12 periods · Measurements and recordings accessible on 7 inch color trouch screen display TRANSIENTS CARRIER CURRENT · True RMS voltage and current measurement · Measurements on all installation types: three-phase, Aron connection, etc. · Electrical network monitoring with setting of alarms · Fast transient events are captured and stored in memory · Communication options: Webserver, Wi-Fi, Ethernet and USB · Power W, VA and var (P, N, Q1, S and D) measurements · Measurement of energy values (total and per phase) with energy valuation INTERHARMONICS (HARMONIC MODE) TRUE INRUSH® · PF, DPF, CF and THD calculations and measurements · Calculation so Pst & Plt flicker and sliding Pst · Harmonics (amplitude/phase shift) from DC to the 63rd order · Inter-harmonic subgroups from 0 to the 62nd order · Calculations of K factor & FHL · 2 carrier current frequencies monitored ACCESSORIES/REPLACEMENTS CATALOG #2140.28 AC/DC Current Probe Model MR193-BK CATALOG #2140.32 AC Current Probe Model MN93-BK CATALOG #2140.33 AC Current Probe Model SR193-BK CATALOG #2140.34 AmpFlex® Sensor 24 in Model 193-24-BK CATALOG #2140.35 AmpFlex® Sensor 36 in Model 193-36-BK CATALOG #2140.36 AC Current Probe Model MN193-BK CATALOG #2140.48 MiniFlex® Sensor 10 in Model MA193-10-BK CATALOG #2140.50 MiniFlex® Sensor 14 in Model MA193-14-BK CATALOG #5100.16 Magnetic Hook Includes FREE DataView® software for configuring, data retrieval, real-time display, analysis and report generation CATALOG #2133.76 Carrying Bag CATALOG #2140.43 Lead - Set of 5, 10 ft (3M) Black Leads w/5 Black Alligator Clips (Leads rated 600 V CAT IV 10 A, Clips rated 1000 V CAT IV 15 A, UL) CATALOG #2140.44 (1) 10 ft (3 M) Black Lead w/(1) Black Alligator Clip (Lead rated 1000 V CAT IV 15 A, Clip rated 1000 V CAT IV 15 A, UL) CATALOG #2140.46 Cable - Replacement 5 ft USB Cable CATALOG #2140.80 Sensor - MiniFlex® Sensor Model MA194-24-BK CATALOG #2960.47 Battery - Replacement 5.8 A·h 61.9 W·h Li-ion Battery Pack CATALOG #5100.14 Adapter - Replacement Power Plug Adapter for PA32ER CATALOG #5100.15 Adapter - Replacement 1000 V PA32ER Power Supply Vol. 23 Rev.00 02/2023 Technical Assistance (800) 343-1391 © Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved. www.aemc.com 109 POWER QUALITY / ENERGY ANALYZERS, METERS & LOGGERS THREE-PHASE POWER QUALITY ANALYZERS NG POWERPAD® III MODELS 8333 & 8336 * U PON R EGIST ERI SD card for trend recordings and data storage, extensive memory for high snapshot quantity, captured transients/inrush and alarm events SPECIFICATIONS MODELS Input Terminals Inputs Voltage (TRMS AC+DC) Voltage Ratio Current (TRMS AC+DC) Frequency (Hz) Distribution Systems Power Values Energy Values Harmonics Transients Flicker (Pst/Plt) Unbalance Recording Alarm Mode Peak Phasor Display Display Snapshots Languages Communication Interface MECHANICAL Battery Life Power Supply Dimensions / Weight SAFETY Safety Rating / IP 8333 4 voltage / 3 current 3 voltage / 3 current 8336 5 voltage / 4 current 4 voltage / 4 current (2 to 1000) V up to 500 kV MN93: 500 mA to 200 AAC; MN193: (0.005 to 100) AAC SR193 Clamp: (1 to 1000) AAC AmpFlex® or MA193 Clamps: 100 mA to 10000 AAC MR193 Clamp: (1 to 1000) AAC/1300 ADC SL261 Clamp: 50 mA to 100 AAC/DC Current Ratio: up to 60 kA (40 to 69) Hz 1P 2W, 1P 3W, 2P 2W, 2P 3W, 1P 2W, 1P 3W, 2P 2W,2 P 3W, 2P 4W, 3P 3W, 3P, 4W, 2P 4W, 3P 3W, 3P, 4W and 3P Split-Phase 2W & 3W 5W, 2 ½ Element and Aron meters and Aron meters W, VA, var, VAD, PF, DPF, cos Ç, tan Ç Wh, varh, VAh, VADh 1st to 50th, Direction, Sequence; THD: 0 to 50, phase up to 51 up to 210 Yes/No Yes/Yes Yes Yes 10 types; 4000 recorded 40 types; 16,000 recorded Yes Automatic Color ¼ VGA TFT screen (320 x 240) diagonal 5.82 in (148 mm) 12 50 > 27 USB 10 h, 15 h in Record mode 9.6 V NiMH rechargeable battery pack (included) External AC supply: (110/230) VAC ±10 % (50/60) Hz (9.8 x 7.8 x 2.6) in (249 x 198 x 66) mm / 4.3 lb (1.95 kg) IEC 61010, 1000 V CAT III; 600 V CAT IV / IP53 8333 SAFETY IP R ATIN G 53 8336 PRODUCT INCLUDES CAT. # 2136.10 MODEL 8333 (NO PROBES) Extra large carrying bag, soft carrying pouch, (4) 10 ft black voltage leads with alligator clips, 5 ft USB cable, (12) color-coded input ID markers, 110/240 V power adapter with US power cord, 9.6 V NiMH battery, SD card, printed quick start guide and USB drive with DataView® software and user manual. CAT. # 2136.30 MODEL 8336 (NO PROBES) Extra large carrying bag, soft carrying pouch, (5) 10 ft black voltage leads with alligator clips, 5 ft USB cable, (12) color-coded input ID markers, 110/240 V power adapter with US power cord, SD card, 9.6 V NiMH battery, printed quick start guide, and USB drive with DataView® software and user manual. Consult factory for NIST Calibration prices KIT OPTIONS 8333 AS ABOVE WITH AMPFLEX® 193 FLEXIBLE CURRENT PROBE OR (10 kA) CATALOG # 2136.11 24 IN, RATED 600 V CAT IV AS ABOVE, MN193 CURRENT PROBE (5/100 A) CATALOG # 2136.12 Rated 600 V CAT III 8336 AS ABOVE WITH AMPFLEX® 193 FLEXIBLE CURRENT PROBE OR (10 kA) CATALOG # 2136.31 24 IN, Rated 600 V CAT IV AS ABOVE, MN193 CURRENT PROBE (5/100 A) CATALOG # 2136.32 Rated 600 V CAT III * 3 YEAR WARRANTY ONLY APPLIES WHEN METER IS REGISTERED WITHIN 30 DAYS OF PURCHASE 110 www.aemc.com Technical Assistance (800) 343-1391 © Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved. Vol. 23 Rev.00 02/2023 POWER QUALITY/ENERGY ANALYZERS, METERS & LOGGERS THREE-PHASE POWER QUALITY ANALYZERS Captures and Records Transients, Events & Waveforms Simultaneously! MODELS 8333 & 8336 Large Functional Displays CONFIGURATION TRANSIENT MODE POWER AND ENERGY MODE PHASOR DIAGRAM RECORDING MODE HARMONICS MODE FEATURES · True RMS single-, two- and three-phase measurements at 256 samples/cycle, plus DC · Real-time color waveforms · Easy-to-use on-screen setup · Automatic current probe recognition and scaling · True RMS voltage and current measurement · Measures DC volts, amps and power · Displays and captures voltage, current and power harmonics to 50th order, including direction, in real-time · Captures transients down to 1/256th of a cycle · Stores comprehensive data base of logged data · Phasor diagram display · kVA, kvar and kW per phase and total · kVAh, kvarh and kWh per phase and total · Neutral current calculated and displayed for three-phase · Transformer Factor K display (8333, 8336) · Power Factor, displacement PF display · Captures up to 210 transients (8336) · Short term (8333) and Long term (8336) flicker display · Phase unbalance (current and voltage) · Harmonic Distortion (total and individual) from 1st to 50th · Alarms, surges and sags · Screen snapshot function captures waveforms or other information on the display · Includes FREE DataView® software for configuring, data retrieval, real-time display, analysis and report generation ACCESSORIES/REPLACEMENTS CATALOG #2133.73 Extra Large Classic Tool Bag (18 x 9 x 12) in CATALOG #2140.28 AC/DC Current Probe Model MR193-BK CATALOG #2140.32 AC Current Probe Model MN93-BK CATALOG #2140.33 AC Current Probe Model SR193-BK CATALOG #2140.34 AmpFlex® Sensor 24 in Model 193-24-BK CATALOG #2140.35 AmpFlex® Sensor 36 in Model 193-36-BK CATALOG #2140.36 AC Current Probe Model MN193-BK CATALOG #2140.40 BNC Adapter for AC/DC Current Probe Model SL261 and models for use with 8220, 8333, 8335, 8336, 8435, 8436 & PEL Series CATALOG #2140.44 (1) 10 ft (3 M) Black Lead w/(1) Black Alligator Clip (Lead rated 1000 V CAT IV 15 A, Clip rated 1000 V CAT IV 15 A, UL) CATALOG #2140.48 MiniFlex® Sensor 10 in Model MA193-10-BK CATALOG #2140.50 MiniFlex® Sensor 14 in Model MA193-14-BK CATALOG #2140.80 MiniFlex® Sensor 24 in Model MA194-24-BK CATALOG #2140.77 Phase Power Adapter (8333 & 8336) CATALOG NO. 2136.10 2136.11 2136.12 2136.30 2136.31 2136.32 DESCRIPTION PowerPad® III Model 8333 (no probes) PowerPad® III Model 8333 w/3 193-24-BK Sensors PowerPad® III Model 8333 w/3 MN193-BK Probes PowerPad® III Model 8336 (no probes) PowerPad® III Model 8336 w/4 193-24-BK Sensors PowerPad® III Model 8336 w/4 MN193-BK Probes Vol. 23 Rev.00 02/2023 Technical Assistance (800) 343-1391 © Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved. www.aemc.com 111 POWER QUALITY / ENERGY ANALYZERS, METERS & LOGGERS THREE-PHASE POWER QUALITY ANALYZERS POWERPAD® III MODEL 8436 Supplied with an 8 GB SD card for storing up to 2 GB trend recordings (4) current and (5) voltage input terminals SPECIFICATIONS MODEL ELECTRICAL Sampling Frequency Data Storage Voltage (TRMS) Current (TRMS) Frequency (Hz) Other Measurements Harmonics Power Supply Battery Life MECHANICAL Communication Port Display Dimensions Weight SAFETY Safety Rating 8436 256 samples/cycle SD card for trend recording; Additional separate 12.5 MB partitioned memory for snapshots, transient / Inrush & alarms Phase-to-Phase: 2000 V Phase-to-Neutral: 1000 V Voltage Ratio: up to 500 kV MN Clamp: (0 to 6) A/120 A or (0 to 240) A SR Clamp: (0 to 1200) A MR Clamp: (0 to 1000) AAC, (0 to 1400) ADC MiniFlex®: (10 to 3000) A AmpFlex®: (10 to 10) kA(1) SL261 Clamp: 50 mA to 100 AAC/DC J93: (50 to 3500) AAC/DC Current Ratio: 10 mA to 60 kA (40 to 69) Hz kW, kvar, kVA, PF, DPF, kWh, kvarh, kVAh, Factor K, Flicker 1st to 50th, Direction, Sequence 9.6 V NiMH rechargeable battery pack (included) (110 to 1000) V DC to 400 Hz 10 h with display on; 15 h with display off (record mode) Optically isolated USB ¼ VGA (320 x 240) color LCD display with adjustable brightness & contrast (10.6 x 9.8 x 7.1) in (270 x 249 x 180) mm 8.2 lb (3.7 kg) with batteries EN 61010, 600 V CAT IV(2), 1000 V CAT III (1) Crest factor at 6500=1 Consult factory for NIST Calibration prices (2) When used with SR193 or AmpFlex® probes 600 V CAT III with MN193 or MR193 probes PRODUCT INCLUDES 8436 KIT CATALOG #2136.44 Extra large tool bag, accessory pouch, 5 ft USB cable, (5) 10 ft black voltage leads with alligator clips, 110 V US power cord, line power cord 110-1000 V DC to 400 Hz, (12) color-coded input ID markers, (4) water-tight AmpFlex® 196A-24-BK sensors (2136.44 only), 9.6 V NiMH battery, SD card, printed quick start guide, high-voltage warning card, and a USB drive with DataView® software and user manual. * UPON REGISTERI SAFETY cover closed R ATIN G FEATURES · Measurement of TRMS voltages up to 1000 Vrms AC/DC for two-, three-, four- or five-wire systems · Measurement of TRMS currents up to 10,000 Arms (sensor dependent) · 65 µs sample rate · Direct measurement of neutral current and voltage · Record and display trend data as fast as once per second for one month for up to 25 variables · Transient detection on all V and I inputs (up to 210) · Selectable PT and CT ratios · Inrush current measurement · Calculation of Crest Factors for V and A · Calculation of Factor K for transformers · Calculation of short and long term flicker and three-phase voltage unbalance · Measures harmonics (referenced to the fundamental or RMS value) for voltage, current or power, up to 50th harmonic · Displays of harmonic sequencing and direction and calculation of overall harmonics · Real-time display of phasor diagrams including values and phase angles · Measurement of active, reactive and apparent power per phase and their respective sum total · Calculation of power factor, displacement power factor and tangent factor · Recording, time stamping and characterization of disturbance (swells, sags and interruptions, exceedance of power and harmonic thresholds) · 2 GB Trend Recording memory; Alarm, Snapshot and Transient/Inrush memories are separate · Measurement of energy kVAh, kvarh & kWh · The Max and Min RMS measurements are calculated every half-period · Includes DataView® software for configuring, real-time display, analysis and report generation NG * 3 YEAR WARRANTY ONLY APPLIES WHEN METER IS REGISTERED WITHIN 30 DAYS OF PURCHASE 112 www.aemc.com Technical Assistance (800) 343-1391 © Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved. Vol. 23 Rev.00 02/2023 POWER QUALITY/ENERGY ANALYZERS, METERS & LOGGERS THREE-PHASE POWER QUALITY ANALYZERS MODEL 8436 Large Color Functional Displays INSTALLATION OF THE LEADS AND CURRENT SENSORS Color-coded ID markers are supplied with the PowerPad® III to identify the leads and input terminals. CONFIGURATION TRANSIENT MODE The voltage and current inputs, as well as the power cord connection are constructed with screw on, watertight connectors rated to IP67. INRUSH PEAK PHASOR DIAGRAM LEAD & ALLIGATOR CLIP POWER CORD Catalog #2140.73 Catalog #5000.63 TREND ANALYSIS HARMONICS MODE AMPFLEX® SENSORS Catalog #2140.75 (Included with Cat. #2136.44 only) LINE POWER ADAPTER Catalog #5000.89 POLE MOUNTING KIT Catalog #2137.82 Set of (2) with hardware ACCESSORIES/REPLACEMENTS CATALOG #2133.73 Extra Large Classic Tool Bag (18 x 9 x 12) in CATALOG #2137.82 Pole Mounting Kit CATALOG #2140.19 Replacement - 9.6 V NiMH Rechargeable Battery CATALOG #2140.45 Set of (12) color-coded Input ID Markers CATALOG #2140.73 (1) 10 ft (3 M) Black Lead (Waterproof cap) (Rated 1000 V CAT IV) and (1) Black Alligator Clip (Rated 1000 V CAT IV, 15 A, UL) CATALOG #2140.75 AmpFlex® Sensor 24 in Model 196A-24-BK (waterproof - IP67) CATALOG #2140.79 MiniFlex® Sensor 14 in Model MA196-14-BK (waterproof - IP67) CATALOG #5000.43 Probe - Set of (2) Color-coded (Red/Black) Magnetize Voltage Probes (Rated 600 V CAT IV, 1000 V CAT III) CATALOG #5000.63 Power Cord 110 V for use only with Models 8435 and 8436 CATALOG #5000.77 Cable Reeling Box CATALOG #5000.89 Line Power Adapter 110-1000 V DC to 400 Hz (Replacement - for use only with Model 8436) CATALOG NO. DESCRIPTION 2136.43 PowerPad® III Model 8436 (No Sensors - Waterproof IP67) 2136.44 PowerPad® III Model 8436 w/4 196A-24-BK (AmpFlex®- Waterproof IP67 ) Vol. 23 Rev.00 02/2023 Technical Assistance (800) 343-1391 © Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved. www.aemc.com 113 POWER QUALITY / ENERGY ANALYZERS, METERS & LOGGERS POWER & ENERGY LOGGER PEL 52 MODEL PEL 52 Time/date stamped electrical measuring instrument to understand and improve electrical consumption NEW SPECIFICATIONS Coming Later this Year! MODEL PEL 52 GENERAL Inputs 2V / 2I Types of installations Single phase, split phase or 2 single-phase channels Recording / Data Storage Rate Unlimited duration (4 GB max recording size) / 1 s to 1 h (Min/Avg/Max) Network Frequency (45 to 65) Hz Voltage (10 to 600) V ELECTRICAL VOLTAGE RANGE RESOLUTION ACCURACY Vrms (10 to 660) V P to N 0.1 V ± 0.2 % Reading ± 0.2 V Urms (20 to 1200) V P to P 0.1 V ± 0.2 % Reading ± 0.4 V CURRENT MEASUREMENT @ (50 and 60) HZ Amps (1 V nominal) (excluding clamp accuracy) RANGE RESOLUTION Probe dependent Probe (0.2 % < I < 120 % Inom) dependent ACCURACY ± 0.2 % Reading ± 0.02 Inom WEB SERVER TM POWER RANGE RESOLUTION ACCURACY Watts P-Q-S (W-var-VA) Power Factor V = (100 to 660) V I = (5 to 120) % Inom Probe dependent ± 0.3 % R ± 0.003 % Pnom ± 1 % R ± 0.01 % Qnom ± 0.3 % R ± 0.003 % Snom Pending IP 54 -1 to 1 0.001 ±0.02 % Cos Ç (DPF) ENERGY -1 to 1 RANGE 0.001 RESOLUTION ±0.05 % ACCURACY Ep-Eq-Es (Wh, varh, VAh) V = (100 to 660) V I = (5 to 120) % Inom 0.001 and ±0.02% ±0.5 % Reading ±2.5 % Reading ±0.5 % Reading MECHANICAL Communication Wi-Fi (access point and hot spot) PRODUCT INCLUDES Data Storage Dimension Weight Case Display Type Real-Time Clock Power Supply Battery Life ENVIRONMENTAL Operating Temperature / Relative Humidity Storage Temperature SAFETY Electro-MagneticCompatibility (EMC) Safety Rating / CE Rating IP Rating 8 GB SD-Card (included); expandable to 32 GB (7.08 x 3.46 x 1.45) in (180 x 88 x 37) mm 14.10 oz (400 g) Compact and rugged, shock and vibration IEC 61010 LCD with blue backlight Time and date stamp for Trend mode From phase 1 (90 to 660) V battery backup when power OFF 3 h without Wi-Fi, 1 h typical with Wi-Fi enabled (-4 to 122) °F (-20 to 50) °C / (10 to 85) % RH (-40° to 158) °F (-40 to 70) °C / (0 to 95) % RH w/out battery EN 61326-1 for emission and immunity IEC/EN 61010-2-30 (600 V CAT III) / Yes IP54 per IEC 60529 CATALOG #2137.69 (WITH PROBES) Soft carrying bag, (2) MiniFlex® MA19310-BK sensors, (3) black test leads and alligator clips, 110 V US power Cord, (1) adapter for power cord, 8 GB SD card, USB SD card reader, (2) AAA rechargeable batteries, quick start guide, and USB drive with DataView® software and user manual. CATALOG #2137.71 (NO PROBES) Soft carrying bag, (3) black test leads and alligator clips, 110 V US power Cord, (1) adapter for power cord, 8 GB SD card, USB SD card reader, (2) AAA rechargeable batteries, quick start guide, and USB drive with DataView® software and user manual. * Minimum and maximum values are current probe dependent. Consult factory for NIST Calibration prices CATALOG NO. 2137.69 2137.71 DESCRIPTION Power & Energy Logger Model PEL 52 (w/LCD, w/2 MA193-10-BK sensors) Power & Energy Logger Model PEL 52 (w/LCD, no sensors) 114 www.aemc.com Technical Assistance (800) 343-1391 © Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved. Vol. 23 Rev.00 02/2023 POWER QUALITY/ENERGY ANALYZERS, METERS & LOGGERS FEATURES · Low cost, simple-to-use, portable, single- and dual- (splitphase) power & energy data logger · Wide backlit LCD display · Install without cutting off the electrical network being monitored · Vital energy data is easily measured, recorded and analyzed · TRMS voltage and current measurement up to 600 V · Powered via the measuring phase · Measurement of the AC phase currents (I1, I2) (dependent on sensor) · RMS AC measurements (50 Hz and 60 Hz), aggregation every second without missing measurements · Easy to use, automatic recognition of current sensors · W, VA and var (P, Q, S, N and D) power measurements · Calculation of the Cos Ç and Power Factor (DPF) · Aggregation measurements over a period from 1 minute to 1 hour · Storage of the 1 s and aggregated measurements on SD/SDHC card; data can be read directly on a PC · Remote connectivity via IRD server · Integrated web server for for remote viewing (AndroidTM, iOS, Windows, etc.) · Wi-Fi offers accessibility to diagnose problems in real-time and/ or multi-station operation. · Data saved on SD card for easier transport · Includes FREE DataView® software for configuring, data retrieval, real-time measurement display, data analysis and report generation · Compact casing with built-in magnets to facilitate mounting for easier implementation in electrical cabinets 2-year warranty · ECO-DESIGN - environmental aspects considered during product development to make the lowest possible environmental impact throughout the product life cycle Large Functional Displays INFORMATION MODE MEASUREMENT MODE (2P-3W2I) Hook up, Wi-Fi, aggregation period, Real-time updates are displayed for can be configured from the front voltage (V), current A) active power (P), panel of the PEL 52. reactive power (Q), apparent power (S), Current ratios and number of turns frequency (Hz), power factor (PF). need to be configured via the PEL Transer software based on the current sensor type. MAX MODE (1P-2W1I) ENERGY MODE Max aggregated values of measurements and energy. Active energy (Wh), reactive energy (varh), apparent energy (VAh). The energies displayed are the total energies, of the source or of the load. (The "h" symbol is not displayed on the screen. You will see W, VA, var for Wh, VAh and varh. Downloaded recordings will show the "h") ACCESSORIES/REPLACEMENTS APPLICATIONS · Load surveys - Find out how much energy each item of equipment consumes operating at its min/max power level. · Energy analysis - Estimate energy consumption before and after the improvements. · Energy surveys - The measurements for energy surveys must be performed at several locations on the evaluation site. Starting with the main power, compare the power and energy measurements on the electricity meter and bills. Sub metering can then be performed on downstream of the installation. CATALOG #2140.32 AC Current Probe Model MN93-BK CATALOG #2140.33 AC Current Probe Model SR193-BK CATALOG #2140.34 AmpFlex® Sensor 24 in Model 193-24-BK CATALOG #2140.35 AmpFlex® Sensor 36 in Model 193-36-BK CATALOG #2140.36 AC Current Probe Model MN193-BK CATALOG #2140.48 MiniFlex® Sensor 10 in Model MA193-10-BK CATALOG #2140.50 MiniFlex® Sensor 14 in Model MA193-14-BK CATALOG #2140.80 MiniFlex® Sensor 24 in Model MA194-24-BK CATALOG #2140.44 (1) 10 ft (3 M) Black Lead w/(1) Black Alligator Clip (Lead rated 1000 V CAT IV 15 A, Clip rated 1000 V CAT IV 15 A, UL) CATALOG #2140.45 Set of (12), color-coded Input ID Markers CATALOG #5000.43 Magnetized Voltage Probe Set of (2) color-coded (Red/Black) magnetized voltage probes (Rated 600 V CAT IV, 1000 V CAT III) Vol. 23 Rev.00 02/2023 Technical Assistance (800) 343-1391 © Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved. www.aemc.com 115 POWER QUALITY / ENERGY ANALYZERS, METERS & LOGGERS POWER & ENERGY LOGGERS PEL 100 SERIES MODEL PEL 102 Monitor your energy usage and costs locally or from anywhere in the world! FEATURES · Simple-to-use, single-, dual- (split-phase) and three-phase (Y, ) power & energy loggers · Designed to work in 1000 V CAT III and 600 V CAT IV environments and fits in many distribution panels · Power measurements: kVA, kW and kvar · Energy measurements: kVAh, kWh (source, load) and kvarh (quadrant indication) · Updated features in DataView® software for configuring real-time communication with a PC and report generation with pre-defined or user defined templates · 8 GB SD card supplied, can be upgraded up to 32 GB · USB, LAN, Ethernet and Bluetooth (Class 1 wireless communication, up to 300 ft away) · Satisfies the monitoring requirements of NEC Code 220.87 · Power adapter allows the PEL 102 to be powered from a phase measurement input · Provides all the necessary functions for power and energy data logging for 50 Hz, 60 Hz, 400 Hz and DC distribution systems · Automatic recognition of the connected current sensors/probes · Magnetic case can be mounted inside power panels PRODUCT INCLUDES PEL 102 KIT CATALOG #2137.51 (SHOWN) Small classic tool bag, (3) MiniFlex® MA193-10-BK sensors, 5 ft USB cable, (4) black test leads and alligator clips, 5 ft 115 V power cord, (12) colorcoded ID markers, safety and compliance sheets, 8 GB SD card with USB-SD card reader, printed quick start guide, and USB drive with DataView® software and user manual. TM ETHERNET SAFETY R ATIN G * IP 54 ACCESSORIES CATALOG #2137.98 Adapter - 600 V CAT III Power Adapter for use with Models PEL 102 & PEL 103 *ADAPTER SOLD SEPARATELY SEE PAGE 120 & 121 FOR MORE OPTIONAL ACCESSORIES Phase Powered ANDROIDTM APP AVAILABLE FOR PEL 102, 103 & 105! · Configure measurements and recordings · Display data in real-time · For use on devices with an AndroidTM platform · NEW software sensors providing all comprehensive and instantaneous motors electrical parameters such as rotation speed, efficiency and torque CATALOG NO. 2137.51 2137.61 DESCRIPTION Power & Energy Logger Model PEL 102 (No LCD, w/3 MA193-10-BK Sensors) Power & Energy Logger Model PEL 102 (No LCD, No Sensors) 116 www.aemc.com Technical Assistance (800) 343-1391 © Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved. Vol. 23 Rev.00 02/2023 POWER QUALITY/ENERGY ANALYZERS, METERS & LOGGERS POWER & ENERGY LOGGERS PEL 100 SERIES MODEL PEL 103 Large Functional Displays INFORMATION MODE MEASUREMENT MODE Hook up, voltage and current ratios and aggregation period can be configured Real-time updates are displayed for voltage, current, power, frequency, TM ETHERNET from the front panel of the PEL 103 power factor and tangent SAFETY * MAX MODE HARMONIC MODE R ATIN G IP 54 FEATURES Max values for voltage, current (including Total Harmonic Distortion (THD) can be neutral current), power and harmonics displayed by phase or phase to phase. Neutral current THD can also be displayed. PRODUCT INCLUDES PEL 103 KIT (W/LCD) CATALOG #2137.52 (SHOWN) Small classic tool bag, (3) MiniFlex® MA193-10-BK sensors, 5 ft USB cable, (4) black test leads and alligator clips, power cord, (12) color-coded ID markers, safety data sheet, compliance sheet, 8 GB SD card with USB-SD card reader, printed quick start user guide, and USB drive with DataView® software and user manual. ACCESSORIES CATALOG #2137.98 Adapter - 600 V CAT III Power Adapter for use with Models PEL 102 & PEL 103 *ADAPTER SOLD SEPARATELY SEE PAGES 120 & 121 FOR MORE OPTIONAL ACCESSORIES Phase Powered · Simple-to-use, single-, dual- (split-phase) and three-phase (Y, ) power & energy loggers · Designed to work in 1000 V CAT III and 600 V CAT IV environments and fits in many distribution panels · Power measurements: kVA, kW and kvar · Energy measurements: kVAh, kWh (source, load) and kvarh (quadrant indication) · Updated features in DataView® software for configuring real-time communication with a PC and report generation with pre-defined or user defined templates · 8 GB SD card supplied, can be upgraded up to 32 GB · USB, LAN, Ethernet and Bluetooth (Class 1 wireless communication, up to 300 ft away) · Satisfies the monitoring requirements of NEC Code 220.87 · PEL 103 can be configured from front panel, DataView® control panel or the FREE AndroidTM application · Provides all the necessary functions for power and energy data logging for 50 Hz, 60 Hz, 400 Hz and DC distribution systems · Automatic recognition of the connected current sensors and probes · Magnetic case can be mounted inside power panel · Supports 17 network configurations CATALOG NO. 2137.52 2137.62 DESCRIPTION Power & Energy Logger Model PEL 103 (w/LCD, w/3 MA193-10-BK Sensors) Power & Energy Logger Model PEL 103 (w/LCD, No Sensors) Vol. 23 Rev.00 02/2023 Technical Assistance (800) 343-1391 © Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved. www.aemc.com 117 POWER QUALITY / ENERGY ANALYZERS, METERS & LOGGERS POWER & ENERGY LOGGERS PEL 100 SERIES MODEL PEL 105 Three-Phase Power and Energy Logger Watertight...great for outdoor use! FEATURES · Simple-to-use, single-, dual- (split-phase) and three-phase (Y, ) power & energy loggers · Designed to work in 1000 V CAT III and 600 V CAT IV environments · Supports 17 different network connections · Power measurements: kVA, kW and kvar · Energy measurements: kVAh, kWh (source, load) and kvarh (four quadrant indication) · Includes DataView® software for configuring, real-time display, analysis and report generation · 8 GB SD card supplied, can be upgraded up to 32 GB · USB, LAN, Ethernet, Wi-Fi and Bluetooth communication (Class 1 wireless communication, up to 300 ft away) · Satisfies the monitoring requirements of NEC Code 220.87 · PEL 105 can be configured from front panel, DataView® control panel or the FREE AndroidTM application · Provides all the necessary functions for power and energy data logging for 50 Hz, 60 Hz, 400 Hz and DC distribution systems · Automatic recognition of the connected current sensors and probes · Powers directly from phase input · Pole mountable ACCESSORIES POLE MOUNTING KIT CATALOG # 2137.82 Set of (2) with hardware SEE PAGES 120 & 121 FOR MORE OPTIONAL ACCESSORIES IP 54 cover open cover closed TM ETHERNET Phase Powered PRODUCT INCLUDES PEL 105 KIT CATALOG #2137.59 (SHOWN) Large classic tool bag, accessory pouch, (5) 10 ft black voltage leads (watertight cap) with alligator clips, (4) water-tight AmpFlex® 196A-24-BK sensors (Cat.# 2137.59 only), (12) color-coded input ID markers, 5 ft USB cable, power adapter 110 V/240 V with US power cord, 9.6 V NiMH battery, 8 GB SD card, USB SD card reader, printed quick start guide, high-voltage waning card, and a USB drive with DataView® software and user manual. CATALOG NO. 2137.57 2137.59 DESCRIPTION Power & Energy Logger Model PEL 105 (No sensors, Waterproof IP67, DataView® Software) Power & Energy Logger Model PEL 105 w/4 196A-24-BK (Waterproof IP67, DataView® Software) 118 www.aemc.com Technical Assistance (800) 343-1391 © Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved. Vol. 23 Rev.00 02/2023 POWER QUALITY/ENERGY ANALYZERS, METERS & LOGGERS POWER & ENERGY LOGGERS PEL 100 SERIES SPECIFICATIONS MODELS PEL 102, PEL 103 & PEL 105 GENERAL Sampling Frequency 128 samples per cycle; (50/60) Hz (16 samples/cycle 400 Hz) Data Storage Rate 1 per second (200 ms also available on PEL 105) Demand Period Storage Rate User selectable (1, 2, 3, 4, 5, 6, 10, 12, 15, 20, 30 and 60 min) Recorded Parameters (Single- and Poly-Phase) V, I, W, VA, var, PF, Tan, Wh, VAh, varh, THD (V and I), Individual harmonics (from 1 through 50 per phase); Crest Factor (CF), Cos f / DPF Event Log Tracks and records status changes and error messages along with recorded data Front Panel Indicator LEDs Bluetooth active, recording in progress, phase connection reversal, overload, battery charging and SD card status Storage Capacity 8 GB SD card included / SD cards up to 32 GB formatted FAT32 are supported INPUTS Voltage PEL 102/103: 3 input channels / PEL 105: 4 input channels via 4 mm safety banana jacks Current PEL 102/103: 3 input channels PEL 105: 4 input channels via custom 4 pin jacks that accept AEMC® Instruments probes and sensors ELECTRICAL VOLTAGE MEASUREMENT RANGE RESOLUTION* ACCURACY* (50/60) Hz (42.5 to 69) Hz ± 0.1 Hz Single-Phase RMS Voltages (10 to 1000) Vrms 0.1 V ± 0.2 % Reading ± 0.2 V Phase-to-Phase RMS Voltages (17 to 1700) Vrms (0.1 to 1) V ± 0.2 % Reading ± 0.4 V 400 Hz (340 to 460) Hz Single-Phase RMS Voltages (10 to 600) Vrms 0.1 V ± 1 % Reading ± 1 V Phase-to-Phase RMS Voltages (17 to 1200) Vrms (0.1 to 1) V ± 1 % Reading ± 1 V DC (100 to 1000) V 0.1 V ± 1 % Reading ± 3 V (typical) PT Ratios Programmable from (50 to 650,000) V (0.01 to 0.1) V CURRENT MEASUREMENT A193 A*** (PEL 102/103) 196 A*** (PEL 105) Nominal range for current probes supplied with kit. (See chart on 200 mA to 10,000 A Pages 32 and 33 for other probes) CT Ratios Programmable from 1:1 to 25,000:1 (probe dependent) POWER MEASUREMENTS RANGE RESOLUTION* ACCURACY* Active Power (P)* (-2 to 2) GW 0.001 W ± 0.5 % Reading ± 0.005 % Pnom Reactive Power (Q)* (-2 to 2) Gvar 0.001 var ± 1 % Reading ± 0.01 % Qnom Apparent Power (S)* (0 to 2) GVA 0.001 VA ± 0.5 % Reading ± 0.005 % Snom Power Factor Tangent Ç (active/reactive power ratio) -1 to 1 -3.2 to 3.2 0.001 0.001 ± 0.05 ± 0.02 ENERGY MEASUREMENTS RANGE RESOLUTION* ACCURACY* Active Energy (EP) 4 EWh 1 Wh ± 0.5 % Reading Reactive Energy (EQ) Apparent Energy (ES) THD Individual Harmonics External Supply Power From Phase Measurement Back-Up Power Supply/Charge Time Battery Life MECHANICAL Communication Dimension/Weight Case Display Type for Models PEL 103 & 105 ENVIRONMENTAL / SAFETY Operating Temperature/Relative Humidity Storage Temperature Safety Rating/CE Rating Ingress Protection 4 Evarh 1 varh ± 2 % Reading 4 EVAh 1 VAh ± 0.5 % Reading ± 655 % 1 to 50 displayed in percentage; 1 to 7 at 400 Hz 110/250 V (10 %) @ (50/60) Hz; 400 Hz PEL 102/103: Requires optional 600 V Power Adapter / PEL 105: Internal up to 1000 VAC Rechargeable 8.4 V NiMH battery pack / Approximately 5 hr 30 min minimum, 60 min typical USB 2.0, Ethernet (RJ45), Wireless Bluetooth Class 1 **/ Wi-Fi (PEL 105) PEL 102/103: (10.08 x 4.92 x 1.46) in (256 x 125 x 37) mm / 2.20 lb (1 kg) PEL (105: 9.8 x 7.8 x 2.6) in (249 x 198 x 66) mm / 8.8 lb (4 kg) Double insulated, rubber over-molded, polycarbonate UL94 V1 rated (2.63 x 2.16) in (67 x 55) mm, four line, monochrome, backlit LCD with adjustable brightness and contrast PEL 102/103/105: (32 to 108.5) °F (0 to 42.5) °C / up to 85 % RH (-4 to 122) °F (-20 to 50) °C with batteries; (-4 to 158) °F (-20 to 70) °C without batteries PEL 102/103: Complies with IEC 61010-1, and IEC 61010-2-030 for 1000 V CAT III / 600 V CAT IV 1000 V CAT IV (PEL 105), Pollution Degree 2 / Yes PEL 102/103: IP54 non operating / PEL 105: IP67 with cover closed Consult factory for NIST Calibration prices * Maximum value is current probe dependent. ** Computers with Class II Bluetooth will restrict range to 40 ft; Computers without Bluetooth will require a Class I or Class II Bluetooth radio adapter. *** Maximum current reduced by a factor of 2 for 400 Hz fundamental frequency. Vol. 23 Rev.00 02/2023 Technical Assistance (800) 343-1391 © Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved. www.aemc.com 119 POWER QUALITY / ENERGY ANALYZERS, METERS & LOGGERS OPTIONAL ACCESSORIES SENSOR TYPE MiniFlex® MA193-BK* & MiniFlex® MA194-BK* CURRENT RANGE ACCURACY (TYPICAL) TYPICAL OENRÿROART (50/60) HZ MAX CONDUCTOR SIZE USED WITH MODEL CATALOG NUMBER 2.75 in (70 mm) (10 in sensor) 2140.48 (10 in sensor) 100 mA to 12,000 AAC(1) 10, 14 or 24 in sensor MR193-BK SR193-BK Battery operated (1 to 1000) AAC (1 to 1300) ADC (1 to 1200) AAC AmpFlex® 193-BK* 100 mA to 12,000 AAC(1) 24 in or 36 in sensor MiniFlex® 196-BK* ± 1 % 3.94 in (100 mm) (14 in sensor) PEL 102 PEL 103 PEL 105 2140.50 (14 in sensor) 0 ° 8333 8336 8436 7.64 in (194 mm) (24 in sensor) 8345 2140.80 (24 in sensor) ± 2.5 % ± 0.3 % -0.80 ° 0.2 ° 1.6 in (41 mm) 2.05 in (52 mm) PEL 102 PEL 103 PEL 105 8333 8336 8436 8345 PEL 102 PEL 103 PEL 105 8333 8336 8436 8345 2140.28 2140.33 ± 1 % 7.64 in (194 mm) (24 in sensor) PEL 102 PEL 103 2140.34 (24 in sensor) PEL 105 0 ° 8333 8336 8436 11.46 in (291 mm) (36 in sensor) 8345 2140.35 (36 in sensor) 3.9 in (99 mm) (14 in sensor) 2140.79 (14 in sensor) Waterproof, IP67 14 in or 24 in sensor 100 mA to 12,000 AAC(1) ± 1 % 0 ° PEL 105 8436 7.64 in (194 mm) (24 in sensor) 2140.75 (24 in sensor) *Maximum current reduced by a factor of 2 for 400 Hz fundamental frequency. All current sensors can be used with Models PEL 105, 8435 and 8436. However, only the MA196-14-BK and 196A-24-BK flexible sensors are waterproof. (1) Current range may be limited by sensor size or meter type. Consult factory for NIST Calibration prices 120 www.aemc.com Technical Assistance (800) 343-1391 © Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved. Vol. 23 Rev.00 02/2023 POWER QUALITY/ENERGY ANALYZERS, METERS & LOGGERS OPTIONAL ACCESSORIES SENSOR TYPE MN93-BK MN193-BK CURRENT RANGE (0.5 to 240) AAC ACCURACY (TYPICAL) TYPICAL OENRRÿOART (50/60) HZ MAX CONDUCTOR SIZE USED WITH MODEL LIMITED RANGE IF USED WITH MODEL CATALOG NUMBER PEL 102 PEL 103 ± 1 % 0.8 ° 0.78 in (20 mm) PEL 105 8333 N/A 2140.32 8336 8345 100 A 200 mA to 120 AAC ± 1 % 0.75 ° PEL 102 PEL 103 0.78 in (20 mm) PEL 105 8333 N/A 2140.36 8336 5 A 5 mA to 6 AAC ± 1 % 1.7 ° 8345 SL261 100 A (5 to 100) AAC/DC ± 4 % ± 0.5 ° PEL 102 PEL 103 0.46 in (12 mm) PEL 105 8333 N/A 1201.51 10 A 50 mA to 10 AAC/DC ± 3 % ± 1 ° 8336 8345 All current sensors can be used with models PEL 105 and 8436. However, only the MA196-14-BK and 196 A-24-BK flexible sensors are waterproof. Consult factory for NIST Calibration prices ACCESSORIES/REPLACEMENTS CATALOG #1201.51 AC/DC Current Probe Model SL261 (BNC) CATALOG #2140.40 BNC Adapter for AC/DC Current Probe Model SL261 ACCESSORIES/REPLACEMENTS CATALOG #2140.34 AmpFlex® Sensor 24 in Model 193-24-BK CATALOG #2140.35 AmpFlex® Sensor 36 in Model 193-36-BK CATALOG #2140.77 Phase Power Adapter for use with PowerPad Models 8333 & 8336 CATALOG #2140.36 AC Current Probe Model MN193-BK CATALOG #2137.98 600 V CAT III Power Adapter for use with Models PEL 102 and PEL 103 only CATALOG #2140.28 AC/DC Current Probe Model MR193-BK CATALOG #2140.32 AC Current Probe Model MN93-BK CATALOG #2140.33 AC Current Probe Model SR193-BK CATALOG #2140.48 MiniFlex® Sensor 10 in Model MA193-10-BK CATALOG #2140.50 MiniFlex® Sensor 14 in Model MA193-14-BK CATALOG #2140.80 MiniFlex® Sensor 24 in Model MA194-24-BK CATALOG #2140.75 AmpFlex® Sensor 24 in (Waterproof - IP67) Model 196A-24-BK CATALOG #2140.79 MiniFlex® Sensor 14 in Waterproof - IP67) Model MA196-14-BK Vol. 23 Rev.00 02/2023 Technical Assistance (800) 343-1391 © Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved. www.aemc.com 121 POWER QUALITY / ENERGY ANALYZERS, METERS & LOGGERS SELECTION CHART AEMC MODEL NUMBER AEMC CATALOG NUMBER INPUT TERMINALS RMS RMS PEAK PEAK VOLTAGE VOLTAGE VOLTAGE VOLTAGE CHANNELS MAX MAX MAX MAX PHASE-TO- PHASE-TO- PHASE-TO- PHASE-TO- NEUTRAL PHASE NEUTRAL PHASE 8333 2136.10 4 V/3 I 3 V/4 I 1000 Vrms 2000 Vrms 1414 Vpk 2828 Vpk DC VOLTAGE MAX 1200 VDC AC CURRENT MAX (PROBE DEPENDENT) DC CURRENT MAX (PROBE DEPENDENT) RATIOS VOLT RATIOS AMPERE 10,000 AAC 5000 ADC Yes Yes 8336 2136.30 5 V/4 I 4 V/4 I 1000 Vrms 2000 Vrms 1414 Vpk 2828 Vpk 1200 VDC 10,000 AAC 5000 ADC Yes Yes 8345 2136.35 5 V/4 I 4 V/4 I 1000 Vrms 2000 Vrms 1414 Vpk 2828 Vpk 1200 VDC 10,000 AAC 5000 ADC Yes Yes 8436 2136.43 5 V/4 I 4 V/4 I 1000 Vrms 2000 Vrms 1414 Vpk 2828 Vpk 1200 VDC 10,000 AAC 5000 ADC Yes Yes PEL 52 2137.71 2 V/2 I 2 V/2 I 660 Vrms 1200 Vrms 3600 AAC No Yes PEL 102 2137.51 4 V/3 I 3 V/3 I 1000 Vrms 1700 Vrms 1414 Vpk 2400 Vpk 1000 VDC 10,000 AAC 5000 ADC Yes Yes PEL 103 2137.52 4 V/3 I 3 V/3 I 1000 Vrms 1700 Vrms 1414 Vpk 2400 Vpk 1000 VDC 10,000 AAC 5000 ADC Yes Yes PEL 105 2137.57 5 V/4 I 4 V/4 I 1000 Vrms 1414 Vpk 2400 Vpk 1000 VDC 10,000 AAC 5000 ADC Yes Yes AEMC AEMC MODEL CATALOG NUMBER NUMBER DISTRIBUTION SYSTEMS PHASE ROTATION WAVEFORM TRANSIENT MODE MODE TRUE INRUSH MODE/TYPE/ DURATION ALARM MODE HARMONIC SNAPSHOT MODE/ MODE INTERHARMONIC MODE TYPE LCD POWER SOURCE 8333 2136.10 1 P-2 W, 2 P-3 W, 3 P-3 W, 3 P-4 W Yes 1 P-2 W, 1 P-3 W, 8336 2136.30 2 P-2 W, 2 P-3 W, 2 P-4 W, 3 P-3 W, Yes 3 P-4 W, 3 P-5 W 1 P-2 W, 1 P-3 W, 8345 2136.35 2 P-2 W, 2 P-3 W, 2 P-4 W, 3 P-3 W, Yes 3 P-4 W, 3 P-5 W 1 P-2 W, 1 P-3 W, 8436 2136.43 2 P-2 W, 2 P-3 W, 2 P-4 W, 3 P-3 W, Yes 3 P-4 W, 3 P-5 W 1 P-2 W, PEL 52 2137.71 2 P-3 W, Yes 1 P-3 W PEL 102 2137.51 Yes 1 P-2 W, 1 P-3 W, 3 PEL 103 2137.52 P-3 W D2, 3 P-3 W O2, 3 P-3 W Y2, 3 Yes P-3 W D3, 3 P-3 W O3, 3 P-3 W Y, 3P-3 W DB, 3 P-4 W Y, 3 P-4 W YB, 3 P-4 W PEL 105 2137.57 Y2 1/2, 3 P-4 W D, 3 Yes P-4 WOD, DC-2 W DC-3 W, DC-4 W No 10 types/ up to 2 active/ 4662 recorded Yes (12) Yes / No TFT - 5.7 in External diagonal adapter with 320 x 240 internal NiMH resolution battery pack Yes (RMS+PEAK & RMS) up to 1 & 10 min 40 types/ up to 7 active/ 16,362 recorded Yes (50) Yes / No TFT - 5.7 in External diagonal adapter with 320 x 240 internal NiMH resolution battery pack Yes (RMS+PEAK & RMS) up to 10 & 30 min 40 types/ Yes DC to 63rd order; 20,000 (no limit < 3 % Udin / w/ email with SD 0 to 62nd order; notificatoins card) < 0.5 % Udin 7 in color LCD touch screen: 800 x 480 (WVGA) External adapter with Li-ion battery pack Yes (RMS+PEAK & RMS) up to 1 & 10 min 40 types/ up to 7 active/ 16,362 recorded Yes (50) Yes / No TFT - 5.7 in Line Power diagonal with internal 320 x 240 NiMH battery resolution pack Power phase No No / No Monochrome input with LCD internal NiMH battery pack No Yes / No None Line Power with internal No Yes / No Monochrome LCD NiMH battery pack Power phase input or No Yes / No Monochrome LCD external adapter with internal NiMH battery pack 122 www.aemc.com Technical Assistance (800) 343-1391 © Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved. Vol. 23 Rev.00 02/2023 TEST(ALNADB)MINESATSRUURMEMENETNST DATA ANALYSIS AND REPORTING SOFTWARE SEE PAGE 133 FOR MORE INFO ON DATAVIEW® SOFTWARE CONFIGURE INSTALLATION TESTERS MODELS CA 6116N & CA 6117 Print reports of all test results / Set instrument parameters and measurement settings on your PC and transfer to the instrument / Retrieve data from the instrument's memory SEE WEBSITE FOR PRICING AND AVAILABILITY: WWW.AEMC.COM TEST AND MEASUREMENT (LAB) INSTRUMENTS DC POWER SUPPLIES & DECADE BOX MODEL AX503 Rugged and accurate power supplies can handle a direct short without causing damage SPECIFICATIONS MODEL Number of Outputs VOLTAGE Output 1 & 2 Output 3 (No display) Display Resolution Basic Accuracy Residual Ripple LINE REGULATION ± 10 % Line Voltage LOAD REGULATION (0 to 2.5) A (0 to 5) A CURRENT Output 1 & 2 Output 3 Resolution Basic Accuracy Limit Indicator Short-Circuit Protection Overheating Protection OUTPUT COUPLING Tracking Series Mode Parallel Mode Power Supply AX503 3 (0 to 30) VDC (2.7 to 5.5) VDC 100 mV ± 0.5 % of Reading ± 1 ct ± 1 mVrms ± 0.03 % of Reading ± 2 mV ± 0.02 % of Reading ± 5 mV ± 0.2 % Reading ± 10 mV (0 to 2.5) A 5 A max (no adjustment) 10 mA ± 0.5 % of Reading ± 1 ct LED, Outputs 1, 2 and 3 Electronic current limitation with voltage shutdown Thermal protection Output 1: Leader/Output 2: Follower Proportional Follower Tracking (0 to 100 % of Leader) (0 to 60) VDC/(0 to 2.5) A (0 to 30) VDC/(0 to 5) A 110 V, (50/60) Hz (220 V optional) Consult factory for NIST Calibration prices FEATURES · Dual (0 to 30) VDC / (0 to 2.5) A outputs · 5.5 V / 5 A output · Series and parallel operation permit (0 to 60) V or (0 to 5) A output · Low noise (< 1 mV ripple) and stable linear technology for clean output · High efficiency toroidal transformers: no fan and low electromagnetic emissions · Active protection against overloads, short circuits and overheating · Unique variable tracking mode for leader/follower operation: follower or leader track proportionally to the original setting · Simultaneous display of voltage and current · Highly visible green (V) and red (A) LED displays ACCESSORIES/REPLACEMENTS CATALOG #2117.78 Lead set includes (2) color-coded (red/black) safety leads, (2) color-coded (red/black) alligator clips (1) ground lead (green), and (2) color-coded (red/black) grip probes MODEL BR07 Bench top decade box that stands up to the task! SPECIFICATIONS TYPES Accuracy Max Current mADC MULTIPLYING FACTOR IN « 1 10 100 1 k 10 k 100 k 1 % ± 10 m 700 mA 200 mA 70 mA 20 mA 7 mA 1 mA 1 M 0.1 mA Consult factory for NIST Calibration prices For more product specifications visit: www.aemc.com/products/decade-boxes/ ACCESSORIES/REPLACEMENTS CATALOG #2131.35 Replacement, 6 ft safety lead, 4 mm female to female for Decade Boxes BR07 FEATURES RESISTANCE DECADE BOX BR07 · Resistance box: 7 decades covering a range from 1 to 11.11111 M · 11-position switches · Output via 4 mm safety banana jacks · Accuracy: 1 % ± 10 m on all ranges CATALOG NO. DESCRIPTION 2130.07 2131.25 DC Power Supply Model AX503 (Triple outputs, two (0 to 2.5) A; (0 to 30) VDC; (2.7 to 5.5) VDC) Resistance Decade Box Model BR07 (x1 , x10 , x100 , x1 k, x10 k, x100 k, x1 M, 1 %) 124 www.aemc.com Technical Assistance (800) 343-1391 © Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved. Vol. 23 Rev.00 02/2023 TEST AND MEASUREMENT (LAB) INSTRUMENTS MULTIFUNCTION INSTALLATION TESTERS MODELS CA 6116N & CA 6117 Safety for your electrical installations and high performance with these unique instruments SPECIFICATIONS MODELS CONTINUITY/RESISTANCE CA 6116N CA 6117 I Rated/Range/Resolution Range/Resolution/Accuracy INSULATION Rated Voltage Range/Resolution/Accuracy Short-Circuit Current I > 200 mA / 39.99 / 0.01 / ± (1.5 % of measurement + 2 cts); 12 mA / 39.99 & 399.9 / 0.01 & 0.1 / ± (1.5 % of measurement + 5 cts) with beep 4 k / 1 / ± (1.5 % of measurement + 5 cts); (40 to 400 k) / (10 to 100 ) / ± (1.5 % of measurement + 2 cts) 50 VDC,100 VDC, 250 VDC, 500 VDC, 1000 VDC 0.01 M to 2 G / 10 k to 1 M / ± (5 % of measurement + 3 cts) 3 mA GROUND RESISTANCE 3-Point Range/Resolution/Accuracy (0.50 to 40) / 0.01 / ± (2 % of measurement + 10 cts); 40 to 15 k / (0.1 to 1) / ± (2 % of measurement + 2 cts); (15 to 40) k / 10 / ± (10 % of measurement + 2 cts) Ufk Complies with SEV 3569 1-Point Selective Range/Resolution/Accuracy (0.20 to 39.99) to (40 to 399.9) / (0.01 to 0.1) / ± (10 % of measurement + 10 cts) (ISel via clamp) LOOP IMPEDANCE (Zs (L-PE) & Zi (L-N or L-L)) / 1-POINT LIVE GROUND Live Ground Installation Voltage/Frequency (90 to 500) V / (15.8 to 17.5) Hz and (45 to 65) Hz HIGH-CURRENT MODE WITH TRIP Zs (L-PE) & Zi (L-N or L-L) Range/Resolution/Accuracy Max. test current: 7.5 A (0.050) (0.100 to 0.5) / 0.001 / ± (10 % of measurement + 20 cts); (0.5 to 3.999) / 0.001 / ± (5 % of measurement + 20 cts); (3.999 to 39.99) / 0.01 / ± (5 % of measurement + 2 cts); (39.99 to 399.99) / 0.1 / ± (5 % of measurement + 2 cts) No TRIP Mode (Zs (L-PE) only) Test current: (6, 9, or 12) mA (as required) (0.20 to 0.99) / 0.01 / ± (15 % of measurement + 10 cts) (1.00 to 1.99) / 0.01 / ± (15 % of measurement + 3 cts) (2.00 to 39.99) / 0.01 / ± (10 % of measurement + 3 cts) (40.00 to 399.9) / 0.1 / ± (5 % of measurement + 2 cts) (400 to 3999) / 1 / ± (5 % of measurement + 2 cts) Calculation of Ik Short-Circuit Current PFC (Zs), I Sc PSCC (Zi) Fault current and short-circuit current: 0.1 A to 20 kA Integrated Fuse Table Voltage Drop V % (Zi) Others AC & A-TYPE RCDs Installation Voltage/Frequency Yes (-40 to 40) % Measurement of the resistive and inductive components of the Zs and Zi impedances (90 to 500) V / (15.8 to 17.5) Hz and (45 to 65) Hz In No TRIP Test Ramp Mode TRIP TIME MEASUREMENT Range/Resolution/Accuracy B-TYPE RCDs Installation Voltage/Frequency In: Ramp/Pulse 2 x In Pulse 4 x In Test in Ramp Mode (10/30/100/300/500/650/1000) mA (90 to 280) V or variable (10/30/100/300/500) mA (280 to 550) V or variable Ramp and pulse test at ½ In Duration: 1000 or 2000 ms 0.2 to 0.5 x In (Uf) / 0.3 x In to 1.06 x In in increments of 3.3 % x In (0.50 to 40) / 0.01 / ± (2 % of measurement + 10 cts); 40 to 15 k / (0.1 to 1) / ± (2 % of measurement + 2 cts); (15 to 40) k / 10 / ± (10 % of measurement + 2 cts) (90 to 275) V / (15.8 to 17.5) Hz and (45 to 65) Hz (10/30/100/300/500) mA and (10/30/100) mA with pulse 4 In Duration: 150 ms with 4 x In or 300 ms with 2 x In 0.2 x In to 2.2 x In TRIP Test: 2 x In & 4 x In IN 200 mA: 2.2 x 2 x In IN > 200 mA: 1.1 x 2 x In IN 100 mA: 2.2 x 4 x In Vol. 23 Rev.00 02/2023 Technical Assistance (800) 343-1391 © Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved. Specifications continued on next page. www.aemc.com 125 TEST AND MEASUREMENT (LAB) INSTRUMENTS MULTIFUNCTION INSTALLATION TESTERS SPECIFICATIONS - CONTINUED MODELS OTHER MEASUREMENTS Current by Clamps C177 Current by Clamp MN77 Voltage Frequency Phase Rotation Active Power Harmonics GENERAL SPECIFICATIONS Display Storage/Communication Power Supply (rechargeable battery) Battery Life Dimensions/Weight SAFETY Safety Rating Ingress Protection EMC *If a voltage is connected to the instrument CA 6116N CA 6117 5.0 mA to 199.9 A (1 mA*) 5.0 mA to 19.99 A (0 to 550) VAC/DC and (15.8 to 500) Hz (10 to 500) Hz (20 to 500) VAC (0 to 110) kW single-phase (0 to 330) kW three-phase Simultaneous display of voltage and current waveforms Voltage and current/up to 50th order / THD-F / THD-R Large 5.7 in backlit graphic color, LCD screen, 320 x 240 points Via USB for data transfer and report creation Li-ion 10.8 V rated 5.8 A·h Up to 30 h (11.02 x 7.48 x 5.04) in (280 x 190 x 128) mm / 4.85 lb (2.2 kg) IEC 61010 -1/600 V CAT III & 300 V CAT IV/IEC 61557 IP53 / IK04 IEC 61326-1 FEATURES · Testing according to the international standards: IEC 60364-6, NF C 15-100, VDE 100, XP C 16-600, etc. · Simple, reliable connection supported by contextual help for each function, including all the connection diagrams · Suitable for all neutral systems (TT, TN, IT) · Type-B RCD testing available (Model CA 6117) · Li-ion battery for a longer battery life · Measurements: voltage, current via clamp, power, waveforms and harmonics · Measurement of voltage drop for correct sizing of conductor diameters · Loop measurement with 1 m resolution · 3-level storage · Includes DataView® analysis software for programming, downloading, storing and report generation of test data · Integrated fuse table for quick reading of the results on the instrument IP 53 PRODUCT INCLUDES Carrying bag, US power cord and charger, Li-ion battery pack, USB A/B cable, set of (3) 3-prong color-coded (red, blue, green) safety voltage leads, set of (3) color-coded (red, blue, green) test probes, set of (3) color-coded (red/blue/green) alligator clips, set of (2) color-coded (red/black) safety leads 4 mm straight plug, 3-prong US measurement cord, remote test probe, wrist strap, hands-free strap, multilingual safety card, and a USB drive with DataView® software and user manual. SPECIAL ORDERS ONLY CATALOG NO. 2138.06 2138.07 2138.10 2138.11 DESCRIPTION Multi-Function Installation Tester Model CA 6116N (US) (includes DataView® Software) - SPECIAL ORDER ONLY Multi-Function Installation Tester Model CA 6117 (US) (includes DataView® Software) - SPECIAL ORDER ONLY Multi-Function Installation Tester Model CA 6116N Kit (US) (includes C177A, DataView® Software) - SPECIAL ORDER ONLY Multi-Function Installation Tester Model CA 6117 Kit (US) (includes C177A, DataView® Software) - SPECIAL ORDER ONLY 126 www.aemc.com Technical Assistance (800) 343-1391 © Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved. Vol. 23 Rev.00 02/2023 THERMAL IMAGING CAMERAS SEE WEBSITE FOR PRICING AND AVAILABILITY: WWW.AEMC.COM THERMAL IMAGING CAMERAS INFRARED CAMERAS MODEL 1954 Versatile tool for performing infrared thermography Indispensable means for ensuring safety in industrial application SPECIFICATIONS MODEL 1954 IR DETECTOR Type UFPA microbolometer Spectral Range 8~14 m Resolution (120 x 160) pixels IMAGING PERFORMANCE NETD 80 mK @ 86 °F (30 °C) Frequency 9 Hz Field of View 28 ° x 38 ° IFOV (spatial resolution) 4.1 mrad Minimal Focal Distance 0.98 ft (0.3 m), fixed focus FOCUSING Adjustment Fixed VISUAL IMAGE Resolution (480 x 640) pixels Minimal Focal Distance 2 in (5 cm), fixed focus PRESENTATION OF IMAGES Images Displayed LCD Screen Infrared image, visual image with automatic parallax compensation. Merging of both images is possible with included PC software 2.8 in (7.1 cm) Display Colors Pseudo-colors, multiple palettes LASER POINTER Type Class 2 645-655 nm power: 1 mW FUNCTIONS Image Freezing Data Storage MEASUREMENT Animated or fixed image 2 GB Micro SD card included (approx. 4,000 images) Replaceable with up to 32 GB SD card Temperature Range (-4 to 482) °F (-20° to 250) °C Accuracy ± 3.6 °F (± 2 °C) or ± 2 % of reading ANALYSIS FUNCTIONS Measurement Tools Adjustment Manual cursor, automatic detection, min/max/avg on adjustable area, temperature profile, and isotherm Automatic or manual adjustment palette min-max Parameter Settings Emissivity, environmental temperature, distance, and relative humidity Isotherm Display Color display of a temperature range adjustable by the user Voice Recordings via Bluetooth headset (included) ENVIRONMENTAL Operating Temperature (-4 to 122) °F (-15 to 50) °C; 95 % RH Storage Temperature (-40 to 158) °F (-40 to 70) °C Humidity (10 to 95) % Drop Resistance 6 ft (2 m) on all sides Impact Resistance 25 G Vibration Resistance 2 G GENERAL Start Up Less than 10 seconds Power Supply (4) AA NiMH rechargeable batteries with external charger included Laser/Output/Wavelength Class 2 / < 1 mW / 645-655 nm Tripod Mounting 1/4 in insert on camera (tripod not included) Battery Life Dimensions/Weight Bluetooth Communication 9 h typical (7 h minimum) (8.86 x 4.92 x 3.27) in (225 x 125 x 83) mm / 24.7 oz (700 g) with rechargeable batteries 407, 607 clamps, DMMs MTX 3292B-BT and MTX 3293B-BT and logger models 1110, 1200 and 1800 Series Safety Rating EN 61326-1: 2006, EN 61010-1 Ed.02 Consult factory for NIST Calibration prices THERMO RESOLUTION (120 X 160) Pixels IP 54 FEATURES · Focus-free with 28 ° x 38 ° field of view · Automatic brightness control · Exceptionally long battery life · Quick startup in less than 10 seconds · User configurable emissivity table · User configurable cursor and trigger functions · User selectable color palette · Captures thermal and real image simultaneously · Verbally record your comments directly to the image using included Bluetooth headset · Wirelessly connect to AEMC® Instruments Clamp-on Meters, Multimeters, and Environmental Meters and record their measurements simultaneously with your thermograms · Comprehensive CAmReport® software included that offers all the necessary functions for reliable analysis of the measurement results and report generation ACCESSORIES/REPLACEMENTS CATALOG #2121.60 Carrying case with foam insert CATALOG #2126.49 USB cable Type A to 5-pin Mini-B 128 www.aemc.com Technical Assistance (800) 343-1391 © Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved. Vol. 23 Rev.00 02/2023 THERMAL IMAGING CAMERAS INFRARED CAMERAS DISPLAY & MENU CONTENTS STATUS BAR Battery Trigger status function Emissivity Date & time of Fixed image: ü current image Dynamic: ü MENU Selectable using navigation keys SD card presence CA Bluetooth logo active FUNCTION KEYS Linked to selected menu choice or camera image CONTEXTUAL HELP This display area updates based on the menu item selected A comprehensive set of easy access menus are available on screen. You can use the function and navigation keys to easily configure the camera for your specific needs. Trigger functions can be programmed, color palettes can be selected, cursor tools can be configured as well as environmental conditions including ambient temperature and humidity, distance and emissivity. SELECTABLE CURSOR TOOLS User programmable cursors provide a comprehensive set of options for evaluating thermal profiles NONE MIN/MAX POINT No cursor display, temperature evaluation is determined by color palette only. ISOTHERM Automatically displays the cold and hot spot values at the Min and Max cursor positions. PROFILE Displays the value at the cursor. Cursor is movable using the navigation keys. SQUARE Displays points that fall in the same temperature range in the same color. User picks green, red or brown as the display color and defines the range and tolerance. Displays the temperature profile of a horizontal line defined by the cursor. Cursor can be moved along the line to get an individual temperature. Displays the Min/Max and mean values within the box. Box size and location is user adjustable. Vol. 23 Rev.00 02/2023 Technical Assistance (800) 343-1391 © Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved. www.aemc.com 129 THERMAL IMAGING CAMERAS INFRARED CAMERAS CAmReport® SOFTWARE FOR ANALYZING THERMOGRAMS This comprehensive software offers all the necessary functions for effective analysis of the measurement results and report generation Report creation is automatic, using one of three available templates. Reports can be exported in Word or PDF format making it simple to print and/or archive them. FEATURES · Transfer measurements from your camera to the software by USB cable, or transportable SD card · Drag-and-drop measurement images from the storage directory to the analysis window in the software · Includes thermal and real images automatically · Superimpose thermal images over real images for better visual analytical results · Locate Min/Max and mean temperatures of the image or an area of the image · User selectable color palette from seven different types · Summary table automatically displays environmental parameters and statistical results of the measurement · Include dictated audio comments into the report with the Bluetooth headset · Includes multiple analytical tools for assessing thermal images · Manually enter measurement analysis findings, site characteristics and operator information to your report · Add graphics such as logos to your reports · Correct the measurement results using built-in or user configured emissivity tables · Include multiple measurements in any report · Save reports as a Word or PDF document PRODUCT INCLUDES Carrying case, USB cable, external battery charger, (4) NiMH rechargeable batteries, micro SD card with adapter, Bluetooth headset, printed quick start guide, and a USB drive with CAmReport software, and user and software manuals. Typical analysis tab screen CATALOG NO. DESCRIPTION 2121.41 Thermal Imaging IR Camera Model 1954 (Resolution 120 x 160) 130 www.aemc.com Technical Assistance (800) 343-1391 © Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved. Vol. 23 Rev.00 02/2023 TRANSFORMER RATIOMETERS DATA ANALYSIS AND REPORTING SOFTWARE SEE PAGE 133 FOR MORE INFO ON DATAVIEW® SOFTWARE CONFIGURE TRANSFORMER RATIOMETERS DTR® MODEL 8510 Display and analyze data on your PC computer / Configure functions and parameters from your PC / Customize views, templates, and reports to your exact needs / Create and store a complete library of configurations that can be uploaded to the instrument / Print reports using standard or custom templates SEE WEBSITE FOR PRICING AND AVAILABILITY: WWW.AEMC.COM TRANSFORMER RATIOMETERS DTR® MODEL 8510 Designed for on-site testing of power, potential and current transformers SPECIFICATIONS MODEL VT/PT Ratio Range CT Ratio Range Accuracy* Excitation Signal Excitation Current Display Excitation Frequency Measurement Method Display Languages Supported Communication Data Storage Power Supply External Charger Battery Life Charging Time SAFETY Safety Rating / IP DTR® 8510 Auto-Ranging 0.8000:1 to 8000:1 Auto-Ranging 0.8000 to 1000.0 Ratio 0.8000 to 9.9999 ± 0.2 % of Reading Ratio 10.000 to 999.99 ± 0.1 % of Reading Ratio 1000.0 to 4999.9 ± 0.2 % of Reading Ratio 5000.0 to 8000.0 ± 0.25 % of Reading VT/PT Mode: 32 Vrms maximum CT Mode: (0 to 1) A, (0.1 to 4.5) Vrms Range: (0 to 1000) mA; Accuracy: ± 2 % of Reading ± 2 mA 70 Hz In accordance with ANSI/IEEE C57.12.90TM-2006 LCD 16 character, 2 line, large format, LED backlight, day/night visible English, Spanish, French, Italian, German, Portuguese Optically isolated USB 2.0 Stores up to 10,000 complete measurements (2) rechargeable 12 V NiMH batteries (included) (90/240) V, (50/60) Hz (smart charger) Up to 10 h continuous operation; May not be used while recharging; Low battery LED/LCD indication < 4 h EN 61010-1; 50 V CAT IV / IP54 (cover closed) Reference Condition: *(23 ± 5) °C, (50 to 70) % RH, full battery charge, no external fields or noise. Consult factory for NIST Calibration prices PRODUCT INCLUDES Soft carrying case, set of (2) 15 ft black leads, set of (2) color-coded (red/black) alligator clips, 10 ft USB cable, external battery charger (90-264 VAC, (50/60) Hz), NiMH batteries (installed), 115 V power cord, and USB drive with DataView® software and user manual. IP 54 cover closed FEATURES · Measures power transformers, VT/PTs and current transformer CT turns ratios · Displays turn ratio, excitation current, winding polarity and % deviation from the nameplate values · Universal voltage (90/240) V supply, (50/60) Hz via external smart/fast battery charger; completely charge in less than 4 hours · Two internal NiMH batteries provide up to 10 hours of continuous operation · Tests performed by exciting the primary and reading the secondary provides safer conditions for the operator · Display warns of incorrect lead connection, reverse polarity, open and short circuits · Easy connection and test setup; no calibration or balancing required · Large dual display with adjustable contrast ensures clearer visibility in any lighting environment day or night · Low battery indicator · Stores up to 10,000 test results in internal memory · USB port facilitates configuring the instrument and downloading test results · Includes DataView® analysis software for programming, downloading, storing and report generation of test data ACCESSORIES/REPLACEMENTS CATALOG #2136.76 Set of (2) leads, 30 ft for DTR® CATALOG #2136.77 Set of (2) leads, 15 ft for DTR® (Replacement) CATALOG NO. DESCRIPTION 2136.50 Digital Transformer Ratiometer DTR® Model 8510 (110 V/220 V) 132 www.aemc.com Technical Assistance (800) 343-1391 © Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved. Vol. 23 Rev.00 02/2023 DATAVRIEEWP® ORDTAITNAGASNOAFLTYWSIASR&E · LOCAL & REMOTE COMMUNICATIONS · CONFIGURE · DOWNLOAD AND STORE RECORDED DATA · ANALYZE · ANNOTATE · CREATE STANDARD AND CUSTOM REPORTS The DataView® software platform designed and developed by AEMC® Instruments, is a comprehensive and powerful analytical and reporting tool used in conjunction with our broad line of electrical test instruments. Our goal in developing this unique software package was to make available one application compatible with any of our instruments that requires software, making it easier for the end-user who operates different AEMC® Instruments products. In this way, learning and using the software does not change with the instrument in use. We also implemented it in such a way that it will be backward compatible with older instruments even as new versions are released and new innovative instruments are supported. Plus, we supply it free with each instrument purchased, and upgrades when released are always free. INSTRUMENTS EQUIPPED WITH DATAVIEW® SOFTWARE: CLAMP-ON METERS MODELS 407, 607 DATA LOGGERS MODELS L261, L562, DL913, DL914 & L452 ENVIRONMENTAL INSTRUMENTS MODELS 1110, 1246, 1821, 1822, 1823 & 1510 GROUND TESTERS MODELS 6417, 6471 & 6472 MEGOHMMETERS MODELS 1060, 5060, 5070, 6526, 6534, 6550, 6555, CA 6116 & CA 6117 MICRO-OHMMETERS MODELS 6240, 6255 & 6292 POWER QUALITY / ENERGY ANALYZERS, METERS & LOGGERS MODELS PEL 52, 102, 103, 105, 8333, 8336, 8345 & 8436 TRANSFORMER RATIOMETER MODEL 8510 SEE WEBSITE FOR PRICING AND AVAILABILITY: WWW.AEMC.COM DDAATTAAVAIENWA®LDYASTIAS A&NRAELYPSOISRTAINNDGRSEOPFOTRWTIANRGESOFTWARE DataView® automatically recognizes a device when it is connected to a PC and starts the corresponding menu providing direct access to a device's recorded data. An end-user can access predefined reports with full safety compliance to current standards for quick editing. They can also define and save their own configured reports, views, etc. as well as the instrument according to their needs saving significant time in the field. STANDARD DATAVIEW® FUNCTIONS For All Applicable Instruments: · Capture, display and analyze real-time data on your PC · Easily configure all functions and parameters specific to each instrument from your PC · Create and store a complete library of configurations that can be uploaded to a device as needed · Create custom views, templates, and reports to your exact needs · Zoom in and out and pan through sections of graphs to analyze the data · View measurements in real-time (model specific), download, display and analyze recorded and stored data · Display waveforms, trend graphs, harmonic spectrums, text summaries, transients, event logs and stored alarms · Print all test result reports using our standard report templates or your custom templates · Free updates available from the help menu on your instrument or on our website: www.aemc.com/resources ADDITIONAL DATAVIEW® FUNCTIONS For Meghommeters: · Select test voltage and run tests from your computer with a simple click and execute process · Retrieve data from the instruments' memory for: Over 1500 insulation resistance measurements Over 4000 resistance measurements · Display DAR and PI ratios · Plot graphs of manual and timed tests · Include your analysis comments section with the report · Store a library of setups for different applications · Certification of results through report generation AUTOMATIC REPORT GENERATION Easily create reports from an instrument with the click of a button. Reports can be displayed on a PC and printed. Each report includes all test results in a tabular and graphic format, as well as operator and test site information. Comments typed by the operator will also be included. 134 www.aemc.com Technical Assistance (800) 343-1391 © Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved. Vol. 23 Rev.00 02/2023 INSTRUMENTS SUPPORTED BY DATAVIEW® · Power Quality/Energy, Analyzers, Meters & Loggers · Ground Resistance Testers · Insulation Resistance Testers · Low Resistance Micro-Ohmmeters · Transformer Ratiometers · Data Loggers · Environmental Loggers · Clamp-on Meters · Installation Testers COMMUNICATION · USB · Wi-Fi · Bluetooth · Ethernet ô INSTRUMENT CONFIGURATION øø · User defined · Load from stored configurations · Save new configurations LOCAL & REMOTE REAL-TIME MONITORING · Single Instrument ù · Multiple Instruments DATA ANALYSIS · Zoom in and out to identify important data points · Annotation and labeling of data points · Tracking Min, Max, Peak and Average values · Object linking and embedding DATA RETRIEVAL þ AND STORAGE · Direct connect to the instrument · Transfer from SD card · Over the internet · From local area network 135 www.aemc.com Technical Assistance (800) 343-1391 © Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved. REPORT GENERATION · Predefined report templates · Customizable report templates · Data Export to other formats (Excel, .csv) · Creation of PDF files Vol. 23 Rev.00 01/2023 DDAATTAAVAIENWA®LDYASTIAS A&NRAELYPSOISRTAINNDGRSEOPFOTRWTIANRGESOFTWARE TYPICAL DATAVIEW® DIGITAL AND GRAPHIC DISPLAYS CLEAR AND SIMPLE SETUP OF ALL FUNCTIONS AND SETTINGS FROM ONE TABBED DIALOG BOX DATA LOGGERS GROUND TESTERS POWER QUALITY / ENERGY ANALYZERS, METERS & LOGGERS ENVIRONMENTAL MEGOHMMETERS Display report waveforms by phase, parameter or total Recorded data displays recorded measurements vs. time as well as min, max, and average measurements for the recording. A movable cursor lets you see values at the cursor location. All stored test results presented on screen Clear and straightforward set up of parameters A typical report will include a plot of the data as well as a listing of the measurements Display harmonics in a text table from harmonic 0 (DC) through the 50th Run test and display text and graphical results from one dialog box. Model 5070 also displays step voltage. Test result status box displays complete test A report cover sheet provides information about results in real-time the operator, test site and a comment section to type in the test results and recommendations. Insulation resistance with temperature compensation Step voltage during the test run Display real-time phasor diagrams with phase angles 136 www.aemc.com Technical Assistance (800) 343-1391 © Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved. Vol. 23 Rev.00 02/2023 DATA ANALYSIS & REPORTING SOFTWARE TYPICAL DATAVIEW® FUNCTIONAL DISPLAYS CLEAR AND SIMPLE SETUP OF ALL FUNCTIONS AND SETTINGS FROM ONE TABBED DIALOG BOX DATA LOGGERS MEGOHMMETERS ENVIRONMENTAL Tabbed dialog boxes allow for clear and easy setup of all functions of the Megohmmeters, including setup for variable voltage and alarm set points, as well as step voltage tests and temperature compensation Typical status screen showing the current state of the instrument GROUND TESTERS Variable Voltage selections from (40 to 5100) V and can also be programmed along with alarm set points (model dependent) The recording configuration screen provides the ability to assign a name & location to the recording session, set the retrieval rate, and schedule when recordings will start and stop. It also displays memory usage Other screens allow for the selection of measurement units, alarm set points, and other user selectable parameters. Configure and control ground resistance tests from your computer through the use of clear and easy-to-use tabbed dialog boxes. All Ground Tester functions can be configured and tests can be initiated with graphical illustration of the proper connections Model 5070 includes Step Function which allows programming of three different ramp test profiles, each containing up to five voltage steps between (40 to 5100) V and time per step of up to 10 hours POWER QUALITY / ENERGY ANALYZERS, METERS & LOGGERS : Configure alarms, inrush and transient capture, network configuration, recording storage rate and length and more. Vol. 23 Rev.00 02/2023 Technical Assistance (800) 343-1391 © Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved. www.aemc.com 137 TRAINING SEMINARS AEMC® INSTRUMENTS TECHNICAL TRAINING WEBINARS & SEMINARS Offered throughout the USA Ground Resistance Testing, Insulation Resistance Testing and Power Quality Public and private courses are available On-site or online training courses UNDERSTANDING GROUND UNDERSTANDING INSULATION RESISTANCE TESTING RESISTANCE TESTING UNDERSTANDING POWER QUALITY For field engineers, technicians, utility engineers, supervisors, electricians and inspectors interested in testing and grounding systems. KEY TOPICS INCLUDE · Soil resistivity · Bond resistance · Ground resistance - 3 and 4 Point Fall-of-Potential testing - Clamp-on testing - Alternate test methods · NEC 250 requirements, NFPA 780 Lightning Protection Standards and IEEE Green Book standards discussed in depth · Continuity testing in common ground systems required by multiple standards · Create plots and reports For technicians, supervisors, electricians, plant maintenance personnel and inspectors interested in insulation resistance testing on motors, cables, transformers and other electrical equipment. KEY TOPICS INCLUDE · Insulation test theory · Insulation testing on motors, cables, and transformers · Spot testing · Timed testing · DAR (Dielectric Absorption Ratio), PI (Polarization Index), DD (Dielectric Discharge) · Temperature correction · Report generation For engineers, technicians, supervisors, electricians, plant maintenance personnel and inspectors interested in monitoring, recording and analyzing power quality and energy monitoring. KEY TOPICS INCLUDE · Symptoms and problems associated with poor Power Quality · Measuring common voltage disturbances and transients · Harmonic Analysis - causes and how to measure harmonics · Bonding issues and their relationship with Power Quality · Power Factor - measuring and understanding its importance to power quality. · IEEE Emerald Book standards discussed in depth FOR THE SCHEDULE OF UPCOMING TRAINING SEMINARS CONTACT [email protected], VISIT OUR WEBSITE AT WWW.AEMC.COM 138 www.aemc.com OR CALL (800) 343-1391 Technical Assistance (800) 343-1391 Vol. 23 Rev.00 02/2023 © Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved. TECHNICAL SALES AND ASSISTANCE If you experience technical problems, or require assistance with the proper use or application of any AEMC® instrument, please call our technical hotline at (800) 343-1391 ext. 351. Technical assistance in Spanish is available at ext. 544. 15 Faraday Drive · Dover, NH 03820 USA Tel: (800) 343-1391 · (603) 749-6434 · Fax: (603) 742-2346 [email protected] · www.aemc.com REPAIR AND CALIBRATION To guarantee your instrument complies with the factory specifications, we recommend that your AEMC® Instruments purchased product be submitted to our factory service center at one year intervals for recalibration, or as required by other standards. For instrument repairs and/or calibrations, please call our factory, toll-free, at (800) 945-2362 ext. 360. Chauvin Arnoux®, Inc. d.b.a. AEMC® Instruments 15 Faraday Drive · Dover, NH 03820 USA Tel: (800) 945-2362 ext. 360 · (603) 749-6434 · Fax: (603) 742-2346 [email protected] · www.aemc.com Costs for repair, normal recalibration, and calibration traceable to NIST are available. NIST calibration pricing is listed within each product ordering chart on our website. All customers must call for an authorization number (CSA#) before returning any instrument. WARRANTY All AEMC® Instruments products carry a 2-year warranty (unless specified) against defects of material and workmanship which develop under normal and proper use within one to three years (product dependent) of original date of purchase when inspection proves the fault to be one of manufacturing. Detailed warranty coverage is located on our website. Products can be registered online at: www.aemc.com/support/product-registration.cfm Specifications and prices are subject to change without notice. CORPORATE AND MANUFACTURING Chauvin Arnoux®, Inc. d.b.a. AEMC® Instruments 15 Faraday Drive · Dover, NH 03820 USA Tel: (603) 749-6434 · Fax: (603) 742-2346 Order entry: Tel: (800) 945-2362 ext. 361 · Fax: (603) 749-9153 [email protected] · www.aemc.com Exports order entry: Tel: +1 (603) 749-6434 ext. 520 · Fax: +1 (603) 742-2346 [email protected] · www.aemc.com ONLINE STORE The AEMC® Instruments online store offers the opportunity to purchase replacement parts such as fuses, test leads and other accessory items for your test instruments. The online store also offers refurbished and discontinued items at a reduced price. Product specials are also offered online so visit our online store regularly at: www.aemc.com/store FIND MORE AT: WWW.AEMC.COM NEW PRODUCTS AC DATA LOGGERS MODELS DL913 & DL914 3 AND 4 CHANNEL AC DATA LOGGERS DL913 DL914 PAGE 38 POWERPAD® IV MODEL 8345 CLASS A POWER/ENERGY QUALITY ANALYZER, METER AND DATA LOGGER A POWERP D IV Class MODEL PEL 52 POWER/ENERGY QUALITY ANALYZER METER AND DATA LOGGER Your authorized AEMC® Instruments distributor is: PAGES 108-109 PAGES 114-115 Chauvin Arnoux®, Inc. d.b.a. AEMC® Instruments 15 Faraday Dr. · Dover, NH 03820-4352 · USA (603) 749-6434 · (800) 343-1391 · Fax (603) 742-2346 · [email protected] Export Department: +1 (603) 749-6434 Ext. 520 · Fax +1 (603) 742-2346 · [email protected] 950.CAT-MASTER-VOL23GPL Ghostscript 10.00.0 Adobe InDesign 18.1 (Windows)