TEST & MEASUREMENT INSTRUMENTS VOLUME 23

PDF Viewing Options

Not Your Device? Search For Manuals or Datasheets below:


File Info : application/pdf, 142 Pages, 15.70MB

Document DEVICE REPORT
PDF aemc - instruments product catalog
TEST & MEASUREMENT INSTRUMENTS

Cable Testers Clamp-On Meters Current Measurement Probes Data Loggers Digital Multimeters Electrical Test Tools Environmental Testers Ground Resistance Testers Leakage Current Meters & Probes Megohmmeters Micro-Ohmmeters Oscilloscopes Power Quality / Energy Analyzers, Meters & Loggers Test and Measurement (Lab) Instruments Thermal Imaging Cameras Transformer Ratiometers

VOLUME 23
WWW.AEMC.COM TECHNICAL HOTLINE: (800) 343-1391
OVER 130 YEARS DEVELOPING ELECTRICAL TEST AND MEASUREMENT INSTRUMENTS

HOW TO ORDER

All AEMC® Instruments products are available through a network of authorized electrical, electronic and instrumentation distributors.
For a list of authorized distributors in your state (US) or country (International), contact AEMC® Instruments or search on the "Where to Buy" tab of our website www.aemc.com
CONTACT SALES & MARKETING
15 Faraday Drive Dover, NH 03820 USA (603) 749-6434 · Fax (603) 742-2346 Technical Hotline: (800) 343-1391 [email protected] · [email protected] · www.aemc.com

ORDERING INFORMATION (WITHIN NORTH AMERICA)
Chauvin Arnoux®, Inc., d.b.a. AEMC® Instruments 15 Faraday Drive Dover, NH 03820 USA (800) 343-1391 ext. 361 · Fax (603) 742-2346 [email protected]

EXPORT DEPARTMENT (ALL COUNTRIES OTHER THAN USA & CANADA)
Tel: +1 (603) 749-6434 ext. 520 Fax: +1 (603) 742-2346 [email protected]

WHEN ORDERING PLEASE USE THE CATALOG NUMBER AND PRODUCT DESCRIPTION Example:

QUANTITY

CATALOG #

DESCRIPTION

1

2137.52

Power & Energy Logger Model PEL 103 (W/LCD, w/3 MA193-10-BK Sensors)

PRICE LIST
A price list is available. Contact your AEMC® Instruments distributor or AEMC® Instruments directly for an up-to-date copy.
AEMC® Instruments reserves the right to discontinue models at any time, or change specifications, price or design without notice and without incurring any obligation. Please contact us, your district sales engineer or distributor for updates.

CHAUVIN ARNOUX®, INC. D.B.A. AEMC® INSTRUMENTS

950.CAT-MASTER-VOL23 Printed in the USA Rev.00 02/2023

FIND MORE AT: WWW.AEMC.COM

TABLE OF CONTENTS

Product Lines
Cable Testers ................................................................................. 3 Clamp-On Meters........................................................................... 7 Current Measurement Probes ..................................................... 15 Data Loggers................................................................................ 35 Digital Multimeters...................................................................... 43 Electrical Test Tools..................................................................... 49 Environmental Testers................................................................. 55 Ground Resistance Testers.......................................................... 65 Leakage Current Meters & Probes.............................................. 79 Megohmmeters............................................................................ 83 Micro-Ohmmeters........................................................................ 95 Oscilloscopes............................................................................... 99 Power Quality / Energy Analyzers, Meters & Loggers .............. 107 Test and Measurement (Lab) Instruments................................ 123 Installation Testers .................................................................... 125 Thermal Imaging Cameras........................................................ 127 Transformer Ratiometers .......................................................... 131
Additional Resources
DataView® Software.................................................................. 133 Training Seminars...................................................................... 138

COMPANY PROFILE

AEMC® Instruments, with US operations in Dover - New Hampshire, began operations in 1976 in downtown Boston - Massachusetts. As a legal entity, AEMC® Instruments is Chauvin Arnoux®, Inc. d.b.a. AEMC® Instruments, and is affiliated with Chauvin Arnoux S.A.S. (Asnieres - France), founded in 1893 and still today a leader in the test and measurement instrument industry. Our products are backed by over 130 years of experien ce in test and measurement instruments, and encompass the latest international standards for quality and safety.
AEMC® Instruments manufactures professional electrical test and measurement instruments for the industrial, commercial and utility marketplace. Product reliability, excellent customer support and expert technical assistance are our top priorities.
AEMC® Instruments is the worldwide industry leading manufacturer of current measurement probes and is an industry leader in ground resistance testers, insulation resistance testers, and power/energy quality analyzers, meters and loggers. Our full product line also includes clamp-on meters, ratiometers, power meters, harmonic power meters, data loggers, thermal imagers, lightmeters, oscilloscopes, micro-ohmmeters and numerous other electrical test tools.
Our Megohmmeter line finds its roots in the early 1900s when Chauvin Arnoux® introduced its first model made from a galvanometer and a decade resistance box combined with a DC power source. Today, AEMC® Instruments megohmmeters are digital and incorporate many intelligent features. Timers, alarms and variable test voltages are standard features. AEMC® Instruments has introduced a unique line of professional 1000, 5000, 10,000, and 15,000 volt megohmmeters with added features, such as: data storage; automated tests and results (internal calculations of DAR, PI, DD and other factors); PC Control; and report compliant software.
Our Ground Tester line finds its roots in the early 1930s. A null balance galvanometer, a decade resistance box and a DC power source combined to make one of the first ground testers on the market. Over 20 years ago, AEMC® Instruments revolutionized the ground testing market by offering clamp-on ground resistance testers, eliminating the need to disconnect the system to test it and the need for auxiliary rods to perform the test. Several generations of improvements and additional features have strengthened AEMC® Instruments position as the industry standard and leader in clamp-on ground resistance testers.
We again led the way in fall-of-potential ground testing with the introduction of an automatic tester in 2006 that automatically locked onto the optimum frequency to test and calculated all the test results for soil resistivity, ground resistance earth coupling and bond resistance, as well as stored the test data and

generated computer reports including fall-of-potential plots. Our tower test system, again, is an innovative design providing the ability to test tower grounding systems without de-energizing them or removing the overhead ground conductor, saving considerable time and money and improving operator safety.
We also manufacture and sell a wide variety of Power and Power Quality measuring instruments ranging from clamp-on meters to single and three-phase power quality analyzers and digital power meters. Our Power & Energy Loggers (PEL) can be used to monitor your power and energy usage and costs locally or from anywhere in the world!
AEMC's DataView® software, designed to configure instruments, run tests, download and store results, and generate final reports was added to the product offering in late the 1990s. Today DataView® is compatible with our Megohmmeters, Ground Resistance Testers, Micro-Ohmmeters, Power Quality Analyzers, Data Loggers and Multi-meters, thus offering a standard for interface and control to all its products, eliminating the need to learn new software every time. Additionally, tablet and Smartphone Apps based on the AndroidTM platform are now available free of charge for our power, ground and clamp-on products. Additionally some products incorporate a remote web server connection for universal communication, regardless of smart device type.
In addition to our product offering AEMC® Instruments offers a oneday accredited course in 'Understanding Ground Resistance Testing' and in 'Understanding Insulation Resistance Testing'. We also offer a 3-day comprehensive class in 'Understanding Power Quality Training'. Completing any of these three courses will give the student all the information they need to conduct resistance testing or power quality analyzing, safely, correctly and efficiently, as well as saving substantial time and money in the future. We also offer technical training online webinar seminars in ground resistance testing and insulation testing. Finally, we offer private classes that can be designed and customized to your specific needs.
Our corporate office comprised of sales, marketing, exports, engineering, production, technical support, product service and NIST calibration is located in Dover, NH. AEMC® Instruments products can be purchased through a worldwide network of distributors who can be found on our website at www.aemc. com. We also offer custom products on an OEM basis.
Visit our website at www.aemc.com to obtain information on our products and services and to get detailed information on attending our seminars. AEMC® Instruments prides itself as being your primary source for test and measurement instruments and training.

Android is a trademark of Google LLC. The Android robot is reproduced or modified from work created and shared by Google and used according to terms described in the Creative Commons 3.0 Attribution License

CABLE TESTERS
SEE WEBSITE FOR PRICING AND AVAILABILITY: WWW.AEMC.COM

CABLE TESTERS
CABLE LOCATOR

MODEL 6681
Detects and locates faults in electrical cables, telecommunication cables, live and de-energized conductors buried or in walls

SPECIFICATIONS
MODEL Display Output Signal Frequency External Voltage Measurement Range
Functions
Power Supply
Dimension
Weight Electrical Safety

6681 (TRANSMITTER) LCD screen with display of functions and bargraph
125 kHz
(12 to 300) VAC/DC
Digital coding of signals for easy signal identification, selection of transmission signal code, flashlight 9 V battery (7.48 x 3.5 x 1.67) in (190 x 89 x 42.5) mm 15 oz (425 g) with battery 300 V CAT III

MODEL
Display
Detection Depth Single and Pole Application Two and Pole Application Single Loopback Line
Line Voltage Detection
Functions
Power Supply
Dimension
Weight Safety Rating Consult factory for NIST Calibration prices

6681 (RECEIVER) Backlit LCD with display of functions and
bargraph, transmission code, receiver and transmitter battery-charge status
(0 to 6) ft (0 to 2) m (0 to 1.6) ft (0 to 0.5) m
Up to 8.2 ft (2.5 m) Approximately (0 to 1.3) ft (0 to 0.4) m Automatic shutdown, automatic or manual adjustment of reception sensitivity, flashlight
(6) 1.5 V AAA batteries (9.5 x 3.07 x 1.5) in (241.5 x 78 x 38) mm 12 oz (340 g) with battery
300 V CAT III

PRODUCT INCLUDES
Soft carrying case, set of (2) color-coded (red/black) leads w/4 mm banana plugs {1000 V CAT III}, set of (2) color-coded (red/black) alligator clips {1000 V CAT II}, adapter-110 V outlet w/ banana plugs, mini ground rod, 9 V battery, (6) AAA batteries and user manual.

RECEIVER

TRANSMITTER

Flashlight
FEATURES
· Operates in both single and two-pole modes · Locates and traces hidden cables · Detects and locates line breaks · Detects faults in floor radiant heating systems · Detects constricted sections of
non-metallic pipes · Detects circuit breakers/fuses · Detects short circuits · Backlight and flashlight functions · Compliant with standards electrical safety
standard EN 61010-1 and electromagnetic compatibility standard EN 61326-1

CATALOG NO. 2127.85

DESCRIPTION Cable Locator Model 6681

4

www.aemc.com

Technical Assistance (800) 343-1391
© Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved.

Vol. 23 Rev.00 02/2023

CABLE TESTERS
FAULT MAPPER

MODEL CA7027
Maps and pinpoints the locations of faults on power and communication cables

SPECIFICATIONS
MODEL MEASUREMENTS
Range @ Vp = 70 %
Range Selection
Resolution
Accuracy Minimum Cable Length Cable Library

CA7027
(23, 49, 98, 197, 394, 820, 1640, 3280, 6560, 9850, 19,000) ft Manual range control Approximately 1 % of selected range ± 1 % of range 1.5 ft (0.5 m)
­

Sensitivity
Velocity of Propagation (Vp)
Output Pulse
Output Pulse Width
Scan Rate Output Impedance Display Resolution Tone Generator Voltage Warning Power Supply Auto Power OFF Weight

Minimum 3 pixel return on a fault at 4 km on 0.6 mm 0, PE, TP
Adjustable from (1 to 99) %
+ 5 V peak to peak into an open circuit
3 ns to 3 ms, Automatic with range 2 scans / second or scan held Selectable between (25, 50, 75 & 100) 
128 x 64 pixel graphical LCD
Oscillating (810 to 1110) Hz ­
(4) 1.5 V AA alkaline batteries
Selectable (1, 2, 3, 5) min or disabled
12 oz (340 g)

PRODUCT INCLUDES
MODEL CA7027
Soft carrying case, set of (2) color-coded (red/black) leads, test probes, alligator clips, (4) 1.5 V AA batteries and user manual.

CA7027 Fault Mapper Pro® Telephone Cable Tester / Graphical TDR
IP 54
Rated
FEATURES
· Built-in tone generator for tracing and locating cables · Large high-visibility blue electroluminescent backlit display · Compatible with industry standard Tone Receivers · Works on de-energized conductors · 11 range scales indicating cable faults and terminations
up to 19,000 ft (58 00 m) in feet or meters · Unique graphical and digital display of fault information and length · Detects opens, shorts, taps, faulty taps, bridge taps, splitters, high
resistance, wet cables, splices and more · Identifies impedance mismatches · Works with twisted pair, parallel and coaxial cable · Dead band less than 9 ft · Selectable cable impedance (25, 50, 75, 100)  · Over-voltage protection up to 250 V · Adjustable cursor assists in locating faults and termination

CATALOG NO. 2127.84

DESCRIPTION Fault Mapper Pro® Model CA7027 (Telephone / Cable Tester / Graphical TDR)

Vol. 23 Rev.00 02/2023

Technical Assistance (800) 343-1391
© Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved.

www.aemc.com

5

As a business of the Chauvin Arnoux® Group, our products are backed by over 130 years of experience and excellence in test
and measurement instruments. We are the brand you can trust!

CLAMP-ON METERS

DATA ANALYSIS AND REPORTING SOFTWARE

SEE PAGE 133 FOR MORE INFO ON DATAVIEW® SOFTWARE

CONFIGURE CLAMP-ON METERS
MODELS 407, 607
Download and store recorded data / Use included default report templates or create custom templates / Print reports of all test results

SEE WEBSITE FOR PRICING AND AVAILABILITY: WWW.AEMC.COM

CLAMP-ON METERS
200, 400 & 600 SERIES GENERAL PURPOSE METERS

MODELS 403/603 & 205/405
Users can be sure of working in a higher degree of safety with 1000 V CAT IV rated meters (model dependent)

SPECIFICATIONS

MODELS

403/603 TRMS

205/405 TRMS

ELECTRICAL Current AC (rms)

(600 / 1000) A

Current DC

(900 / 1500) A

Current AC+DC Voltage AC (rms) Voltage DC Voltage AC+DC Ohms Continuity (Buzzer) Diode Test THD Single- and 3-Phase Real Power (AC, DC, AC/DC)* Single- and 3-Phase Reactive Power (AC, DC, AC/DC)* Single- and 3-Phase Apparent Power (AC, DC, AC/DC)* Temperature (int., ext., °C, °F) Voltage Frequency Current Frequency Power Factor THD-r / THD-f Current Probe Adapter Function (AC/DC) Phase Rotation Auto AC/DC Auto Power OFF Hold Button Backlight Button Min/Max Button True InRush® Function Relative Function Peak ± Function Hz Button

­

(900 / 1500) A

(1000 / 1000) V

(1000 / 1000) V

­

(1000 / 1000) V

(60 / 100) k

Yes (< 40 )

Yes

­

Yes (model 405)

­

(600 / 1000) kW

­

(600 / 1000) kvar

­

(600 / 1000) kVA

Yes

­

20 kHz

(3 / 2 / 1) kHz

­

Yes

­

Yes / Yes

(0 to 10) V

­

­

Yes (2 wire)

Yes (V & A)

Yes

Yes

Yes

Yes

Yes

Yes

­

Yes

Yes

*Three-phase measurements assume balanced load Consult factory for NIST Calibration prices

403

603

205

405

*

*205 only
IP 40
FEATURES
· 1000 V CAT IV Rated (Models 403, 603 & 405) · UL 94 VI flame retardant self-extinguishing · 10,000-count (400 & 600 series) and 6000 count
(200 series) blue electroluminescent backlit display · Measures up to 1000 VAC (1400 V peak), 1000 VDC and
AC+DC with resolution to 10 mV · Measures up to 2000 AAC and 3000 ADC (Model dependent) · Measures W, VA, var and PF for single- and three-
phase balanced systems (Models 205 & 405) · Measures frequency to 20 kHz with 0.1 Hz resolution · Auto selects AC or DC measurement voltage · True InRush® current measurement with 100 mS
capture · Jaw opening up to: 1.34 in (34 mm) (200 series),
1.89 in (48 mm) (400 series), 2.36 in (60 mm) (600 series) · K-thermocouple and adapter included (Models 403 & 603)
PRODUCT INCLUDES
Catalog #2139.21, #2139.31 Includes set of (2) color-coded silicone insulated test leads, test probes and alligator clips, K-thermocouple with 4 mm integrated adapter, soft carrying case, (4) 1.5 V AA batteries, and user manual. Catalog #2139.40 Includes set of (2) 5 ft (1.5 m) needle tip color-coded leads with 4 mm right angle plug, soft carrying case, (1) 9 V battery and user manual. Catalog #2139.50 Includes set of (2) color-coded silicone insulated test leads, test probes and alligator clips, soft carrying case, (4) 1.5 V AA batteries and user manual

CATALOG NO. DESCRIPTION

2139.21

Clamp-On Meter Model 403 (TRMS, 1000 VAC/DC, 1000 AAC/1500 ADC, Ohms, Continuity, Temperature)

2139.31 2139.40

Clamp-On Meter Model 603 (TRMS, 1000 VAC/DC, 2000 AAC/3000 ADC, Ohms, Continuity, Temperature) Power Clamp-On Meter Model 205 (TRMS, 1000 VAC/DC, 600 AAC/900 ADC, Ohms, Continuity, Phase Rotation, Power, THD)

2139.50

Power Clamp-On Meter Model 405 (TRMS, 1000 VAC/DC, 1000 AAC/1500 ADC, Phase Rotation, Ohms, Continuity, Power, THD)

8

www.aemc.com

Technical Assistance (800) 343-1391
© Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved.

Vol. 23 Rev.00 02/2023

CLAMP-ON METERS
400 & 600 SERIES BLUETOOTH EDITION
POWER AND HARMONIC METERS

MODELS 407 & 607 Now available with AndroidTM mobile application

SPECIFICATIONS

MODELS

407 TRMS 607 TRMS

ELECTRICAL

Current AC (rms)

1000 A

2000 A

Current DC

1500 A

3000 A

Current AC+DC

1500 A Peak 3000 A Peak

Voltage AC (rms)

1000 V

Voltage DC

1000 V

Voltage AC+DC

1000 V

Ohms

100 k

Continuity (Buzzer)

Yes (< 40 )

Total Harmonic Distortion

Yes

Individual Harmonics (to 25th)

Yes

Single- and 3-Phase Real Power (AC, DC, AC/DC)*

1000 kW

Single- and 3-Phase Reactive Power (AC, DC, AC/DC)*

1000 kvar

2000 kvar

Single- and 3-Phase Apparent Power (AC, DC, AC/DC)*

1000 kVA

2000 kVA

Voltage Frequency

20 kHz

Current Frequency

2 kHz

1 kHz

Power Factor

Yes

THD-r / THD-f

Yes / Yes

Auto AC/DC

Yes (V & A)

Auto Power OFF

Yes

Hold Button

Yes

Backlight Button

Yes

Min/Max Button

Yes

True InRush® Function

Yes

Peak ± Function

Yes

Harmonics Function

Yes

Rec (Record) Function

Yes

Wireless BT (Bluetooth) Function

Yes

Record (Recordings)

1000

Hz Button

Yes

*Three-phase measurements assume balanced load Consult factory for NIST Calibration prices

407

607

IP 40
FEATURES
· 1000 V CAT IV Rated · UL 94 VI flame retardant self-extinguishing · 10,000-count blue electroluminescent backlit display · Measures up to 1000 VAC (1400 V peak), 1000 VDC and
AC+DC with resolution to 10 mV · Measures up to 2000 AAC and 3000 AAC (Model 607) · Measures single- and three-phase power (real, reactive and
apparent) up to 3 MW with resolution to 1 W · Measures frequency to 20 kHz with 0.1 Hz resolution · Auto selects AC or DC measurement · True InRush® current measurement with 100 mS capture · Measures harmonics up to the 25th · Records up to 1000 measurements · Bluetooth communication (communicates up to 30 ft) · Includes FREE DataView® software for download and
report generation · Jaw opening up to
1.89 in (48 mm) (400 series) 2.36 in (60 mm) (600 series)

PRODUCT INCLUDES
Hard carrying case, set of (2) color-coded silicone test leads, test probes and alligator clips, Bluetooth USB adapter, (4) 1.5 V AA batteries, safety information sheet, and USB drive supplied with DataView® software and user manual.

CATALOG NO. DESCRIPTION

2139.51

Power Clamp-On Meter Model 407 (TRMS, 1000 VAC/DC, 1000 AAC/1500 ADC, Ohms, Continuity, Energy, Harmonics, Power, THD, Recording)

2139.61

Power Clamp-On Meter Model 607 (TRMS, 1000 VAC/DC, 2000 AAC/3000 ADC, Ohms, Continuity, Energy, Harmonics, Power, THD, Recording)

Vol. 23 Rev.00 02/2023

Technical Assistance (800) 343-1391
© Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved.

www.aemc.com

9

CLAMP-ON METERS
500 SERIES

MODEL 505
Small compact size clamp-on meter that fits comfortably in a tool bag

SPECIFICATIONS
MODEL ELECTRICAL AC Current (Auto-Ranging) Resolution AC Voltage (Auto-Ranging) Resolution Input Impedance DC Current (Auto-Ranging) Resolution DC Voltage (Auto-Ranging) Resolution Input Impedance Resistance Max Test Voltage Continuity Max Test Voltage Zero Mode / Delta Function Peak + / - Function MECHANICAL Dimensions Weight Jaw Opening Power Supply Battery Life ENVIRONMENTAL Operating Temperature Storage Temperature Operating Humidity Pollution Degree SAFETY Safety Standards Consult factory for NIST Calibration prices

505
(0.05 to 400) A (0.01 and 0.1) A (0.5 to 600) V
(0.1 and 1) V 10 M
(0.10 to 400) A (0.01 and 0.1) A (0.2 to 600) V
(0.1 and 1) V 10 M
(0.2 to 600)  1.5 VDC < 35  1.5 VDC Yes Yes / No
(7.83 x 2.95 x 1.42) in (199 x 75 x 36) mm 8.57 oz. (243 g) with batteries 1.18 in (30 mm) (2) AAA, IEC LR3 (included) 40 h
(+32 to 104) °F (0 to 40) °C (+14 to 140) °F (-10 to 60) °C
< 70 % 2
EN/IEC 61010 to 600 V CAT III

Jaw Opening: 1.18 in (30 mm) Conductor Size: 500 kcmil cable
FEATURES
· Compact size - fits into your pocket · 400 AAC or 400 AAC/DC current measurements · 600 VAC/DC volts measurements · Resistance measurements to 600  · Continuity with beeper below 35  · Hold function to "freeze" readings · Push-button for easy ADC zeroing · Large, easy-to-read 6000-cts LCD Display · 42-segment analog bar graph · Includes test leads and soft carrying pouch
PRODUCT INCLUDES
Soft carrying case, set of (2) color-coded (red/black) test leads with probe tips, (2) 1.5 V AAA batteries and user manual.

CATALOG NO. 2139.82

DESCRIPTION Clamp-On Meter Model 505 (TRMS, AC/DC, 400 AAC/DC, 600 VAC/DC, Ohms, Continuity) RATED 600 V CAT III

10 www.aemc.com

Technical Assistance (800) 343-1391
© Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved.

Vol. 23 Rev.00 02/2023

CLAMP-ON METERS
500 SERIES (CONTINUED)

MODEL 514
Full ranges and compliance to international safety and quality standards ensure a professional and reliable tool

SPECIFICATIONS

MODELS

514 TRMS

AC Current (Auto-Ranging) Resolution

(0.05 to 1000) Arms (0.01, 0.1and 1) A

AC Voltage (Auto-Ranging) Resolution
Input Impedance DC Current (Auto-Ranging)
Resolution DC Voltage (Auto-Ranging)

(0.5 to 750) Vrms 0.1 V and 1 Vrms
10 M (1 to 1000) A 0.01 A, 0.1 A and 1 A (0.2 to 1000) V

Resolution

0.1 V and 1 V

Input Impedance Resistance

10 M (0.2 to 4000) 

Max Test Voltage Diode Test

3 VDC 1.7 mA

Open Circuit Voltage

3 VDC

Continuity

< 40 

Max Test Voltage

3 VDC

Frequency (Auto-Ranging)

CURRENT INPUT Range
Min Input Signal
VOLTAGE INPUT Range
Min Input Signal
Power Supply

4 kHz 10 kHz
4 kHz 10 kHz
4 kHz 10 kHz
4 kHz 10 kHz

1 Hz Resolution 10 Hz Resolution
2 Arms 5 Arms
1 Hz Resolution 10 Hz Resolution
5 Vrms 10 Vrms 9 V Alkaline battery (included)

ENVIRONMENTAL

Operating Temperature

(*-14 to 122) °F (-25 to 50) °C, 80 % RH, non-condensing

Consult factory for NIST Calibration prices

*Note: If Model 514 is to be used below 32 °F (0 °C), we suggest that the battery be replaced to ensure proper results.

Jaw Opening: 1.575 in (40 mm) Conductor Size: (1) 750 kcmil cable or (2) 350 kcmil cables
514
FEATURES
· Standard size, full function clamp-on meter · 1000 AAC or 1000 AAC/DC current measurements · Measures up to 750 VAC and 1000 VDC · TRMS measurements · Resistance measurements to 4000  · Continuity with beeper below 40  · Frequency measurements from V and A · Diode test · 1 ms peak function for fast capture of signals · Hold function to freeze readings · Push-button for easy ADC zeroing · Large, easy-to-read, 4000-count LCD display · 42-segment analog bargraph · Includes test leads, soft carrying pouch and batteries
PRODUCT INCLUDES
Soft carrying case, set of (2) color-coded (red/black) test leads with probe tips, 9 V battery and user manual.

CATALOG NO. 2117.70

DESCRIPTION Clamp-on Meter Model 514 (AC/DC, TRMS, 1000 AAC/DC, 750 VAC/1000 VDC, Hz, Ohms, Continuity)

Vol. 23 Rev.00 02/2023

Technical Assistance (800) 343-1391
© Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved.

www.aemc.com 11

CLAMP-ON METERS
100 AAC/DC LOW CURRENT

MODEL CM605
For general industrial monitoring and troubleshooting

SPECIFICATIONS

MODEL ELECTRICAL AC Current
Measurement Ranges Frequency Range DC Current (positive only) Measurement Ranges AC Volts Measurement Ranges Frequency Input Impedance DC Volts (positive only)* Measurement Ranges Input Impedance Resistance (Ohms) Measurement Ranges Test Voltage Continuity Measurement Ranges Resolution Test Voltage Analog Output Output Frequency Output Impedance Other Functions ADC Zero & Relative Function
HOLD Function
PEAK Function
Auto-Ranging Over Range Auto Power OFF Low Battery Mechanical Max. Cable Diameter Max. Jaw Opening Power Supply Dimensions Weight

CM605
2 Ranges: 10 A, 100 A (50 to 500) Hz
2 Ranges: 10 A, 100 A
600 Vrms (40 to 500) Hz
10 M
600 V 10 M
10 k (9999 ) < 3.0 VDC
Buzzer < 100  ± 25  1 
< 3.0 VDC
10 mV/AAC & ADC through front banana jacks (0 to 20) kHz @ ± 3 db 3 k, < 50 pF
One touch push button to Zero ADC, or other readings. Relative function to compare two measurements. Holds A & V measurements when pressed (HOLD button) Captures PEAK (1 ms) V or A measurement when activated (PEAK Button) "AUTO" displayed on LCD "OL" displayed on LCD for all measurements Auto Power OFF after approx 10 min with Over-Ride Low Battery indication on LCD
Ø 0.45 in (12 mm) Ø 0.60 in (15 mm) (2) 1.5 V AAA (LR03) batteries (included) (7.44 x 2.80 x 1.46) in (189 x 71 x 37) mm
6.5 oz (184 g)

SAFETY

Safety Rating

IEC/EN 61010-1 and 2-032 ­ 600 V CAT II and 300 V CAT III ­ Pollution Degree 2 Class 2 ­ Double or reinforced insulation, CE mark

*For negative measurement, add 2 cts to the accuracy Consult factory for NIST Calibration prices

CATALOG NO. 7000.02

DESCRIPTION Clamp-on Meter Model CM605 (100 AAC/DC, Low Current)

FEATURES
· 10,000-count LCD display · 100 AAC/DC Ammeter with low 10 A range
(1 mA resolution)* · Analog output in AAC/DC to data loggers,
oscilloscopes and more · Tapered jaws for crowded wiring areas
Jaw opening: Ø 0.60 in (15 mm) Cable diameter: Ø 0.45 in (12 mm) · 600 VAC/DC voltmeter · Auto-ranging and ADC zero push-button · Data HOLD and PEAK functions · Relative function to compare two measurements · Ohm range and continuity test with beeper · Auto Power OFF and low battery indicator · IEC/EN 61010 safety rated and CE mark · 600 Vrms overload protection
PRODUCT INCLUDES
Soft carrying case, set of (2) color-coded (red/black) test leads with probe tips, (2) 1.5 V AAA batteries and user manual.

12 www.aemc.com

Technical Assistance (800) 343-1391
© Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved.

Vol. 23 Rev.00 02/2023

CLAMP-ON METERS
SELECTION GUIDE

Models

Catalog Number

Type

AC Current

AC Voltage

DC Current

DC Voltage

Resistance («)

Continuity

Frequency (Hz)

Current Voltage

205

2139.40

AC/DC TRMS

600 A

1000 V 900 A 1000 V

60 k«

< 40 « 3 kHz

20 kHz

Jaw Size
1.34 in (34 mm)

Dimensions (8.7 x 3.1 x 1.65) in

403

2139.21

AC/DC TRMS

1000 A

1000 V 1500 A 1000 V

100 k«

< 40 «

2 kHz

20 kHz

1.89 in (48 mm)

(10.7 x 3.6 x 1.6) in

405

2139.50

AC/DC TRMS

1000 A

1000 V 1500 A 1000 V

100 k«

< 40 «

2 kHz

20 kHz

1.89 in (48 mm)

(10.7 x 3.6 x 1.6) in

407

2139.51

AC/DC TRMS

1000 A

1000 V 1500 A 1000 V

100 k«

< 40 « 2 kHz

20 kHz

1.89 in (48 mm)

(10.7 x 3.6 x 1.6) in

603

2139.31

AC/DC TRMS

2000 A

1000 V 3000 A 1000 V

100 k«

< 40 « 1 kHz

20 kHz

2.36 in (60 mm)

(11.65 x 4.37 x 1.61) in

607

2139.61

AC/DC TRMS

2000 A

1000 V 3000 A 1000 V

100 k«

< 40 « 1 kHz

20 kHz

2.36 in (60 mm)

(11.65 x 4.37 x 1.61) in

505

2139.82

AC/DC TRMS

400 A

600 V 400 A 600 V

600 «

< 35 « 400 Hz 400 Hz

1.18 in (30 mm)

(7.83 x 2.95 x 1.42) in

514

2117.70

AC/DC TRMS

1000 A

750 V 1000 A 1000 V

4000 «

< 40 « 10 kHz

10 kHz

1.58 in (40 mm)

(9.53 x 2.60 x 1.42) in

566*

2139.83

AC TRMS

100 A

600 V

2

600 V

600 k«

< 45 « 500 Hz 500 Hz

0.91 in (23 mm)

(8.27 x 3.0 x 1.32) in

CM605 7000.02 AC/DC 100 A 600 V 100 A 600 V 9999 « < 100 « 500 Hz 500 Hz
*Model 566 can be found in the Leakage Current Meters & Probes on Page 80 Consult factory for NIST Calibration prices

0.60 in (15 mm)

(7.95 x 2.76 x 1.33) in

Vol. 23 Rev.00 02/2023

Technical Assistance (800) 343-1391
© Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved.

www.aemc.com 13

We've got you covered. Our products encompass the latest international standards for quality and safety and our product warranties provide maximum equipment protection. We are the brand you can trust!

CURRENT MEASUREMENT PROBES
AEMC® INSTRUMENTS PROBES ARE UNIVERSAL! SEE WEBSITE FOR PRICING AND AVAILABILITY: WWW.AEMC.COM

CURRENT MEASUREMENT PROBES
MINIFLEX® SERIES

HIGH FREQUENCY OSCILLOSCOPE
COMPATIBLE MINIFLEX® PROBES
A compact AC current measurement device composed of a flexible sensor, a BNC connector, and an electronic module designed to measure frequency response up to 1 MHz

SPECIFICATIONS
MODELS ELECTRICAL Current Range Measurement Range Accuracy Signal Output Frequency Range Influence of Conductor Positioning Influence of Conductor Positioning in Sensor Against Handle External Conductor Influence Power Supply MECHANICAL Sensor Diameter Sensor Length Max Conductor Size Connection Cable Length Drop Test Vibration Mechanical Shock Weatherproofing ENVIRONMENTAL Operating Temperature Range Storage Temperature Range
Altitude
SAFETY
Safety Rating

MF 300-10-2-10-HF

MF 3000-14-1-1-HF

30 A / 300 A

3000 A

(0.5 to 300) A

(0.5 to 3000) A

1 % ± 300 mA

100 mV / 10 mV/A

1 mV/A

5 Hz to 1 MHz @ -3 db

1.5 % typical, 3 % max

4 % typical, 6 % max
(35 to 40) db on contact 9 V Alkaline battery (6 LF22)

Ø 0.2 in (5 mm)

10 in (254 mm)

14 in (355 mm)

2.75 in (70 mm)

3.93 in (100 mm)

6.5 ft (2 m)

15.75 in (400 mm)

Per IEC 68-2-32

Per IEC 68-2-6

Per IEC 68-2-27

IP50

(14 to 131) °F (-10 to 55) °C (-40 to 158) °F (-40 to 70) °C Operating: (0 to 6562) ft (0 to 2000) m, working voltage derating above; Non-operating: (0 to 39,000) ft (0 to 12,000) m
Housing: EN 61010 600 V CAT III, 300 V CAT IV Sensor: EN 61010 1000 V CAT III, 600 V CAT IV

MF 300-10-2-10-HF (10 in probe)
MF 3000-14-1-1-HF (14 in probe)
SAFETY R ATIN G
FEATURES
· Measures from (0.5 to 3000) Arms · Accuracy ± 1 % of Reading ± 0.3 A · TRMS measurements when connected to a
TRMS instrument · No core saturation or damage if overloaded · 9 V battery for typical 150 hours continuous
operation · 1 MHz frequency response · Low phase shift for power measurements · Insensitive to DC, measures only
AC component on AC + DC signals · Excellent linearity · Lightweight · Sensor is resistant to oils and aliphatic
hydrocarbons · Perfect accessory for any BNC oscilloscope

CATALOG NO. DESCRIPTION

2126.84

MiniFlex® 30/300 A, 10 in, 100 mV/10 mV/A High Frequency (for any BNC Oscilloscope)

2126.86

MiniFlex® 3000 A, 14 in, 1 mV/A High Frequency (for any BNC Oscilloscope)

16 www.aemc.com

Technical Assistance (800) 343-1391
© Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved.

Vol. 23 Rev.00 02/2023

CURRENT MEASUREMENT PROBES
MINIFLEX® SERIES

MODEL MA114
Provides a welcomed solution when accessing electrical conductors in tight places or clamping onto cable bundles

SPECIFICATIONS

MODEL

MA114

ELECTRICAL

Nominal Range

3 AAC; 30 AAC; 300 AAC; 3000 AAC

Measurement Range

3 A Range: (0.5 to 3) AAC, 30 A Range: (2 to 30) AAC, 300 A Range: (5 to 300) AAC, 3000 A Range: (50 to 3000) AAC

Transformation Ratio

Voltage Output

Output Signal

3 A Range: 1 V/A (1 mV/mA) (3 VAC @ 3 A), 30 A Range: 100 mV/A (3 VAC @ 30 A), 300 A Range: 10 mV/A (3 VAC @ 300 A), 3000 A Range: 1 mV/A (3 VAC @ 3000 A)

Phase Shift

 1 ° (0.5 ° typical)

Overload

3 A Range: 4.5 A, 30 A Range: 45 A, 300 A Range: 450 A, 3000 A Range: 4500 A

Frequency Range

3000 A Range: 10 Hz to 10 kHz, 3 A, 30 A, 300 A Range: 10 Hz to 20 kHz

Load Impedance

 1 M

Working Voltage

600 Vrms (CAT IV), 1000 Vrms (CAT III)

Power Supply Battery Life

(2) 1.5 V AA batteries or LR6 alkaline, +5 VDC with Type B micro-USB
300 hours typical. Approximately 1,800 10-minute measurements.

Output Termination

1.6 ft (0.5 m) lead with (2) 4 mm safety banana plugs

MECHANICAL

Sensor Length

14 in (35.6 cm)

Cable Length

6.5 ft (2 m)

Maximum Conductor Size

Ø 3.93 in (10 cm)

Dimensions

(4.7 x 2.3 x 1.4) in (12 x 5.8 x 3.6) cm

Weight

Approximately 10.58 oz (300 g)

ENVIRONMENTAL

Operating Temperature

(14 to 131) °F (-10 to 55) °C

Storage Temperature

(-40 to 158) °F (-40 to 70) °C

Operating Relative Humidity

(0 to 95) % RH @ 95 °F (35 °C)

SAFETY

Safety Rating

IEC 61010-2-32 Type B, 1000 V CAT III, 600 V CAT IV, Pollution Degree 2

Electromagnetic Compatibility

IEC 61326-1

Ingress Protection

IP54 (electronic unit), IP67 (flexible sensor)

Double Insulation

Yes

Consult factory for NIST Calibration prices

SAFETY

R ATIN G
3 AAC 1 mV/mA

30 AAC 100 mV/A

IP 67
300 AAC 3000 AAC 10 mV/A 1 mV/A

FEATURES
· 14-inch flexible sensor capable of clamping around a 3.93 inch cable or bundle
· Waterproof sensor rated to IP67
· User selectable ranges of (3, 30, 300 and 3000) Amps
· 600 V CAT IV, 1000 V CAT III rated
· Not affected by magnetic saturation, provides excellent linearity and low phase shift
· Battery or USB powered for long term use
· Red LED indicates overload condition
· Positive click locking sensor eliminates disconnection errors
· Banana plug termination compatible with multimeters, data loggers and other instruments

CATALOG NO. 2153.41

DESCRIPTION MiniFlex® 14 in Model MA114 (3 A/1 mV/mA, 30 A/100 mV/A, 300 A/10 mV/A, 3000 A/1 mV/A)

Vol. 23 Rev.00 02/2023

Technical Assistance (800) 343-1391
© Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved.

www.aemc.com 17

CURRENT MEASUREMENT PROBES
FLEXIBLE CURRENT PROBES

AMPFLEX® FLEXIBLE CURRENT PROBES

Flexible AC current probe composed of a flexible sensor and an electronic module

SPECIFICATIONS

MODELS

MEASUREMENT OUTPUT

RANGE

SIGNAL

SENSOR LENGTH

MAX CONDUCTOR
SIZE

CATALOG NO.

300-24-2-10

30/300 A 100/10 mV/A

24 in (610 mm)

8 in (203 mm) 2112.88

300-120-2-10 30/3000 A 100/10 mV/A 120 in (3048 mm) 38 in (970 mm) 2113.39

1000-24-1-1

1000 A

1 mV/A 24 in (610 mm) 8 in (203 mm) 2112.39

1000-24-2-1 100 A /1000 A 10/1 mV/A 24 in (610 mm) 8 in (203 mm) 2112.98

1000-36-2-1 100/1000 A 10/1 mV/A 36 in (914 mm) 11 in (279 mm) 2113.00

3000-24-1-1

3000 A

1 mV/A 24 in (610 mm) 8 in (203 mm) 2112.46

3000-36-1-1

3000 A

1 mV/A 36 in (914 mm) 11 in (279 mm) 2112.48

3000-24-2-1 300 A /3000 A 10/1 mV/A 24 in (610 mm) 8 in (203 mm) 2113.05

3000-36-2-1 300/3000 A 10/1 mV/A 36 in (914 mm) 11 in (279 mm) 2112.00

3000-48-2-1 300/3000 A 10/1 mV/A 48 in (1219 mm) 15 in (381 mm) 2112.01

6000-36-2-0.1 600/6000 A 1/0.1 mV/A 36 in (914 mm) 11 in (279 mm) 2113.21

30000-24-2-0.1 3000/30,000 A 1/0.1 mV/A 24 in (610 mm) 8 in (203 mm) 2113.33

Consult factory for NIST Calibration prices. Consult factory for special offers and ranges/lengths not shown. Note: Output is safety shrouded 4 mm male banana plug.

FLEXPROBE® FLEXIBLE CURRENT PROBE MODEL 24-3001

SAFETY
R ATIN G
FEATURES
· Models ranging from (0.5 to 30,000) Arms · Accuracy ± 1 % of Reading · TRMS measurements when connected to a
TRMS instrument · No core saturation or damage if overloaded · Over range LED for measurement circuitry · Waterproof sensor · 9 V Alkaline battery, typically provides
150 hours of continuous operation (battery included) · Shape memory for custom pre-shaping of sensor before use (no drooping) · Very high frequency response · Low phase shift for power measurements of < 1.3 °, 0.7 ° typical · Insensitive to DC, measures only AC component on DC + AC signals · Excellent linearity · Lightweight

Low cost AC current measurement probe designed to plug into digital multimeters, oscilloscopes and power recorders

SPECIFICATIONS

MODEL ELECTRICAL Current Range
Output Signal
Three Position Slide Switch 10 mV/A 1 mV/A ON/OFF
Power Supply MECHANICAL Maximum Conductor Size Sensor Length Cable Length
Output Termination

24-3001
300 AAC / 3000 AAC mV output
(4000 mV peak max)
5 A to 300 Arms 50 A to 3000 Arms
9 V Alkaline battery (included)
7.6 in (193 mm) 24 in ± 1 in (610 ± 25) mm
6.5 ft (2 m) Double insulated 14 in (356 mm) lead with safety banana plugs

Consult factory for NIST Calibration prices

CATALOG NO. DESCRIPTION

2120.81

FlexProbe® Model 24-3001 (Lead)

FEATURES
· 24-inch flexible sensor fits around conductors up to 7.6 inch in diameter
· Dual measurement ranges of 300 A and 3000 AAC.
· Read amperage directly on DMM display
· mV output directly proportional to the AC current measured
· Output is 10 mV/A on 300 A range and 1 mV/A on 3000 A range
· Accuracy of ± 1 % of Reading ± 500 mA
· 4 % influence of conductor position in jaw
· Dual banana plug termination for direct input into DMMs
· Flashing LED low battery indicator
· 9 V Alkaline battery, provides typical 150 hours of continuous operation (battery included)

SAFETY
R ATIN G
ACCESSORIES
BANANA (FEMALE) BNC (MALE) (XM-BB) Catalog #2118.46 (optional for AmpFlex® & FlexProbe® Flexible Current Probes)

18 www.aemc.com

Technical Assistance (800) 343-1391
© Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved.

Vol. 23 Rev.00 02/2023

CURRENT MEASUREMENT PROBES
DC/AC MICROPROBES AND CURRENT PROBES

MD SERIES & K SERIES

MD Series probes are rugged and designed for use

on cables and bus bars

MD301

K100

K Series small probes are designed for high accuracy measuring low currents

SPECIFICATIONS

MODEL

MD301

ELECTRICAL

Nominal Range Measurement Range Transformation Ratio

500 AAC (2 to 500) AAC Voltage output

Output Signal

1 mV/A (0.5 VDC @ 500 A)

Phase Shift

25 A 100 A 250 A 500 A 600 A

­ ­ ­ ­ ­

Overload

700 A for 10 min

Frequency Range

(48 to 1000) Hz (error: add 2 % to the ref.)

Load Impedance

 100 k

Working/Common Voltage

600 Vrms

Output Termination

Double-insulated 5 ft (1.5 m) lead with (2) 4 mm safety banana plugs

MECHANICAL

Jaw Opening

1.3 in (33 mm)

Maximum Conductor Size

1.18 in (30 mm), Max Bus Bar size: (2.48 x 0.20) in (63 x 5) mm

Dimensions

(2.6 x 7.68 x 1.34) in (66 x 195 x 34) mm

Weight

14.82 oz (420 g)

Material

Polycarbonate UL 94

ENVIRONMENTAL

Operating Temperature

(5 to 122) °F (-15 to 50) °C

Storage Temperature

(-40 to 185) °F (-40 to 85) °C

SAFETY

Electrical

EN 61010-2-032 600 V CAT III, Pollution: 2; 300 V CAT IV, Pollution: 2

Electromagnetic Compatibility

EN 50081-1 Class B; EN 50082-2 Electrostatic discharge IEC 1000-4-2;
Radiated field IEC 1000-4-3; Fast transients IEC 1000-4-4; Magnetic field at (50/60) Hz IEC 1000-4-8

Consult factory for NIST Calibration prices

CATALOG NO. DESCRIPTION

1201.07

AC Current Probe Model MD301 (500 A, 1 mVDC/AAC, Lead)

1200.67

DC/AC MicroProbe Model K100 (4.5 A, 1 mV/mA)

2111.73

DC/AC MicroProbe Model K110 (450 mA, 10 mV/mA)

SPECIFICATIONS

MODELS

K100

K110

ELECTRICAL

Current Range

(0 to ± 4.5) ADC (0 to 3) Arms

(0 to ± 450) mADC (0 to 300) mArms

Output Signal

1 mV/mA

10 mV/mA

Resolution

DC: 50 µA typical, AC: 100 µA typical

Output Noise

< 100 µV, DC to 3 kHz

Frequency Response
Output Termination

DC to 2 kHz (@ -3 dB sine)

DC to 1.5 kHz (@ -3 dB sine)

5 ft (1.5 m) lead with (2) 4 mm safety banana plugs; standard ¾ in (19 mm) spacing

Power Supply

(1) 9 V Alkaline battery (included)

Battery Life

20 hours

Consult factory for NIST Calibration prices

FEATURES
MD SERIES · 500 A range with mA or mV output · Unique hook-shaped jaws that enable the user to pry into or
hook onto cables · Maximum conductor size is (2 x 500) kcmil · Works as a traditional current transformer with ratio of 1000:1 · AC/DC outputs available K SERIES · Measures extremely low level DC from 100 µA · Outputs signal proportional to total current (DC + AC) · Low noise · Ultra-compact size and non-contact clamp-on convenience · Simple plug-in operation · Designed for use with digital multimeters and oscilloscopes · Accurate display of waveforms · No range or mode (AC/DC) switching required · Red LED indicates momentary or continuous overload · Green LED indicates power and battery condition

ACCESSORIES
Catalog #1017.45 Adapter ­ 4 mm Non-insulated for Safety Leads
Catalog #2118.46 Adapter - Banana (Female) ­ BNC (Male) (XM-BB) 600 V CAT III

Vol. 23 Rev.00 02/2023

Technical Assistance (800) 343-1391
© Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved.

www.aemc.com 19

CURRENT MEASUREMENT PROBES
SL SERIES AC/DC CURRENT PROBES

SL SERIES
Compact, long nose probes designed for accurate measurements of low currents with 10 mADC sensitivity, capable of measuring both AC and DC current

SPECIFICATIONS
MODELS ELECTRICAL Nominal Range Measurement Range Transformation Ratio
Output Signal
Phase Shift (DC to 65 Hz) 1 mV/mA Range 10 mV/mA Range
100 mV/mA Range Overload
Frequency Range
Load Impedance Working/Common Mode Voltage
Output Termination
MECHANICAL
Operating Relative Humidity
Maximum Conductor Size Dimensions Weight Material ENVIRONMENTAL Operating Temperature Storage Temperature SAFETY Electrical CE Mark UL Approval Consult factory for NIST Calibration prices

SL261
10 A; 100 AAC/DC peak 100 mA to 100 AAC/DC peak
Voltage output 10 A: 100 mV/A (1 V @ 10 A) 100 A: 10 mV/A (1 V @ 100 A)
­ < 1 ° < 1.5 ° Red LED indicator DC to 100 kHz (-3 dB with current derating) > 1 M/100 pF
600 Vrms
6.5 ft (2 m) coaxial cable with insulated BNC terminal
(10 to 30) °C: 85 ± 5 % RH (without condensation) (40 to 50) °C: 45 ± 5 % RH (without condensation)
0.46 in (11.8 mm) (9.09 x 1.42 x 2.64) in (231 x 36 x 67) mm
11.6 oz (329 g) with battery Polycarbonate UL 94
(32 to 122) °F (0 to 50) °C (-22 to 176) °F (-30 to 80) °C
EN 61010-2-32, 600 V CAT III Yes Yes

SL261 W/ BNC CONNECTOR
FEATURES
SL SERIES AC/DC CURRENT PROBES · Low AC and DC measurements · Measures from 10 mA to 100 A · Dual range selection · Unique design for probing in
crowded|wiring areas · Hall effect sensor technology · UL approved for the United States and
Canada · Flame retardant UL94 V2 rated · Use with DMMs, voltmeters and
other voltage measuring instruments

CATALOG NO. 1201.51

DESCRIPTION AC/DC Current Probe Model SL261 (10 A, 100 mV/A & 100 A, 10 mV/A, BNC)

20 www.aemc.com

Technical Assistance (800) 343-1391
© Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved.

Vol. 23 Rev.00 02/2023

CURRENT MEASUREMENT PROBES
SR SERIES CURRENT PROBES

SR600 SERIES
Current probes well-suited for power applications where high accuracy and low phase shift is important

SPECIFICATIONS

MODELS

SR601

SR604

SR651

SR661

ELECTRICAL Nominal Range Measurement Range Transformation Ratio Output Signal
Phase Shift
Overload Frequency Range Load Impedance Working/Common Mode Voltage Output Surge Protection
Output Termination
MECHANICAL Jaw Opening Maximum Conductor Size Maximum Bus Bar Size Dimensions Weight Material ENVIRONMENTAL Operating Temperature Storage Temperature Operating Relative Humidity SAFETY Electrical UL Approval

1000 AAC

1000 AAC

10, 100, 1000 AAC

0.1 to 1200 AAC

1000: 1

Voltage output

1 mA/A (1 AAC @ 1000 A)

1mV/A

100 mV; 10 mV; 1 mV/A

(1 VAC @ 1000 A) (1 VAC @ 10, 100; 1000 A)

10 A: 3 ° 50 A: 1.5 ° 200 A: 0.75 ° 1000 A: 0.5 ° 1200 A: 0.5 °

(10 A Range) 10 A:  15 ° (100 A Range) 20 A:  15 ° 100 A:  10 ° 120 A:  5 ° (1000 A Range) 200 A:  3 ° 1000 A:  2 ° 1200 A:  1 °

1200 A for 40 min ON, 20 min OFF

30 Hz to 5 kHz*

10 Hz to 100 kHz*

5  max

100 k min

1 M min

600 V CAT III

30 V peak

(2) 4 mm Lead

safety banana with

jacks

plugs

(2) 4 mm safety banana jacks

N/A
6.5 ft (2 m) coaxial cable with BNC terminal

2.25 in (57 mm) max
2.05 in (52 mm)
(1) (1.95 x 0.19) in (50 x 5) mm (4.37 x 8.50 x 1.77) in (111 x 216 x 45) mm
1.21 lb (550 g) Polycarbonate UL 94

(14 to 122) °F (-10 to 50) °C (-4 to 158)°F (-20 to 70) °C
(0 to 85) % RH decreasing linearly above 95 °F (35 °C)

EN 61010-2-32, 600 V CAT III Yes - United States and Canada

Consult factory for NIST Calibration prices

SR601
FEATURES
· Measurement range of 100 mA to 1200 AAC
· Large jaw opening accommodates up to two 500 kcmil conductors
· Ergonomic design and easy operation · Low phase shift for power measurements · Available with mA or mV output signals · Designed for DMMs, recorders, loggers,
oscilloscopes, power and harmonic meters · UL approved
ACCESSORIES
Catalog #1017.45 4 mm Banana plug adaptor (Safety Leads to non-recessed plug) Catalog #2118.46 Banana (Female) BNC (Male) Adaptor
*Current derating above 1 kHz using the formula: 1000 A x 1/F (in kHz)

CATALOG NO. 2113.43 2113.44 2113.45 2113.49

DESCRIPTION AC Current Probe Model SR601 (1000 A, 1 mA/A, Jack) L** AC Current Probe Model SR604 (1000 A, 1 mA/A, Lead) L** AC Current Probe Model SR651 (1000 A, 1 mV/A, Jack) AC Current Probe Model SR661 (10 A, 100 mV/A; 100 A, 10 mV/A & 1000 A, 1 mV/A, BNC)

Vol. 23 Rev.00 02/2023

Technical Assistance (800) 343-1391
© Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved.

**L - Limited open Voltage Output www.aemc.com 21

CURRENT MEASUREMENT PROBES
SR SERIES CURRENT PROBES

SR700 SERIES
Excellent linearity and low phase shift, plus a broad frequency response, permit accurate measurements of current for power and power quality measurements

SPECIFICATIONS

MODELS ELECTRICAL Nominal Range Measurement Range Transformation Ratio
Output Signal
Phase Shift
Overload Frequency Range Load Impedance Working/Common Mode Voltage
Output Termination
MECHANICAL Jaw Opening Maximum Conductor Size Maximum Bus Bar Size Dimensions Weight Material ENVIRONMENTAL Operating Temperature Storage Temperature Operating Relative Humidity SAFETY Electrical UL Approval

SR701

SR704

SR752

SR759

1000 AAC

1 mA to 1200 AAC

100 mA to 1200 AAC

1, 10, 100, 1000 AAC 1 mA to 1200 AAC

1000: 1

Voltage output

1 mA/A

1 mV/A

1000, 100, 10, 1 mV/A,

(1 AAC @ 1000 A)

(1 VAC @ 1000 A)

(1 VAC @ 1, 10, 100 or 1000 A)

(1 A Range)

(0.1 to 1.2) A:  10 °

(10 A Range)

(1 to 10) A:  2 °

(0.1 to 1) A:  5 °; (1 to 12) A:  2 °

(10 to 100) A:  1 °

(100 A Range)

(100 to 1200) A:  0.7 °

(1 to 10) A:  2 °; (10 to 120) A:  1 °

(1000 A Range)

(10 to 100) A:  2 °; (100 to 1200)

A:  1 °

1200 A for 40 min ON, 20 min OFF

30 Hz to 5 kHz; current derating above 1 kHz using the formula: 1000 A x 1/F (in kHz)

5  max

100 k min

600 V CAT III

(2) 4 mm safety banana jacks

5 ft (1.5 m) lead with 4 mm safety banana plugs

2.25 in (57 mm) max 2.05 in (52 mm)

(1) (1.95 x 0.19) in (50 x 5) mm
(4.37 x 8.50 x 1.77) in (111 x 216 x 45) mm 1.21 lb (550 g)
Polycarbonate UL 94

(0 to 85) %

(14 to 122) °F (-10 to 50) °C (-4 to 158) °F (-20 to 70) °C
(0 to 90) %

EN 61010-2-32 Yes - United States and Canada

Consult factory for NIST Calibration prices

SR701
FEATURES
· Measurement range of 1 mA to 1200 AAC
· Large jaw opening accommodates conductors up to two 500 MCM conductors
· Ergonomic design and easy operation
· Low phase shift for power measurements
· Available with mA output signals
· Designed for DMMs, recorders, loggers, oscilloscopes, power and harmonic meters
· UL approved
ACCESSORIES
Catalog #1017.45 4 mm Banana plug adaptor (Safety Leads to non-recessed plug) Catalog #2118.46 Banana (Female) BNC (Male) Adaptor

CATALOG NO. DESCRIPTION

2116.29

AC Current Probe Model SR701 (1000 A, 1 mA/A, Jack) HA* L**

2116.30

AC Current Probe Model SR704 (1000 A, 1 mA/A, Lead) HA* L**

2116.32 2116.33

AC Current Probe Model SR752 (1000 A, 1 mV/A, Lead) HA* AC Current Probe Model SR759 (1 A, 10 A, 100 A, 1000 A, mV/A, Lead) HA*

*HA - High Accuracy and Low Phase Shift, **L - Limited open Voltage Output

22 www.aemc.com

Technical Assistance (800) 343-1391
© Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved.

Vol. 23 Rev.00 02/2023

CURRENT MEASUREMENT PROBES
MN SERIES AC CURRENT PROBES

MN SERIES
Small and compact, ideal complement for any meter to measure AC currents in low-power secondary transformers or industrial applications

SPECIFICATIONS

Patent #1385787 - Mini-Clamp Design

MODELS

MN01

MN02

MN05

MN09

ELECTRICAL Nominal Range

150 AAC

100 AAC

10 AAC; 100 AAC

150 AAC

Measurement Range

(2 to 150) AAC

50 mA to 100 AAC (1  load)
50 mA to 90 AAC (10  load)

5 mA to 10 AAC (1 to 100) AAC

(1 to 150) AAC

Transformation Ratio

1000:1

Voltage output

N/A

Output Signal

1 mA/A (150 mAAC @ 150 A)

1 mA/A (100 mAAC @ 100 A)

1 mV/mA, 1 mV/A (10 VAC @ 10 A,
100 mVAC @ 100 A )

100 mV/A (15 VDC @ 150 AAC)

Phase Shift

Not specified

< 3 ° (1  load) < 6 ° (10  load)

Not specified

Overload

170 A for 10 min ON, 30 min OFF

10 A Range: 15 A 170 A for 10 min ON,

100 A Range: 150 A

30 min OFF

Frequency Range

(48 to 500) Hz 48 Hz to 10 kHz

(48 to 500) Hz

Load Impedance

 10 

 1 M

 50 K

Open Secondary Voltage

 30 V

­

 30 V

Output Termination

5 ft (1.5 m) lead with (2) 4 mm safety banana plugs

MECHANICAL

Maximum Conductor Size

Ø 0.39 in (10 mm)

Dimension

(5.12 x 1.5 x 1) in (130 x 38 x 25) mm

Weight

6.35 oz (180 g)

Material

Polycarbonate UL 94 V2

ENVIRONMENTAL

Operating Temperature

(14 to 122) °F (-10 to 50) °C

Storage Temperature

(-40 to 176) °F (-40 to 80) °C

Operating

Relative Humidity

(0 to 85) % RH decreasing linearly above 95 °F (35 °C)

SAFETY

Safety Rating

IEC 61010-2-32: 300 V CAT IV, 600 V CAT III, Pollution Degree 2

Ingress Protection

IP40

Consult factory for NIST Calibration prices

MN01

*

IP

40

*MN09 only

FEATURES
· Clothes pin shape makes them ideal for use in tight areas, such as breaker panels, controller panels or outlets
· Jaw opening accommodates conductors up to 0.39 in diameter
MN01
· Measurements from 2 A to 150 AAC
· Excellent companions to all DMMs, permits very low AC current measurements
MN02
· Measurement ranges: 50 mA to 100 A (1  load) 50 mA to 90 A (10  load)
· Designed for DMMs, loggers, recorders and oscilloscopes
· (48 to 10,000) Hz frequency range
· 1 mA/A from (1 to 10)  load output signals
MN05
· Measurements from 5 mA to 100 AAC
· Permits very low AC current measurements
MN09
· Measurements from (1 to 150) AAC
· DC voltage output enables you to overcome low AC sensitivity of certain measurement instruments

CATALOG NO. 2129.17 2129.20 2129.19 2129.21

DESCRIPTION AC Current Probe Model MN01 (150 A, 1 mA/A, Lead) AC Current Probe Model MN02 (100 A, 1 mA/A, Lead, 1 % Accuracy) AC Current Probe Model MN05 (100 A, 1 mV/A & 10 A, 1 V/A, Lead) AC Current Probe Model MN09 (150 A, 100 mVDC/AAC, Lead)

Vol. 23 Rev.00 02/2023

Technical Assistance (800) 343-1391
© Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved.

www.aemc.com 23

CURRENT MEASUREMENT PROBES
MN SERIES AC CURRENT PROBES

MN SERIES Compact sized probes ideal for measuring low currents and leakage currents
Standard millivolt or milliamp outputs are compatible with multimeters, data loggers and oscilloscopes

SPECIFICATIONS

Patent #1385787 - Mini-Clamp Design

MODELS

MN103

MN114

MN185

ELECTRICAL

Nominal Range

10 AAC, 100 AAC

10 AAC

120 AAC

Measurement Range
Transformation Ratio

1 mA to 10 AAC (1 to 100) AAC
Voltage output

1 mA to 10 AAC Voltage output

50 mA to 120 AAC 1000:1

Output Signal

1 mV/mA, 1 mV/A (10 VAC @ 10 A, 100 mVAC @ 100 A)

100 mV/A (1 VAC @ 10 A)

1 mA/A (120 mAAC @ 120 A)

Phase Shift

­

(10 to 100) A, (45 to 65) Hz: 8 °

(1 to 100) A, (50 to 60) Hz:  3.5 °

Overload

­

20 A continuous

170 A continuous

Frequency Range

(45 to 500) Hz

(30 to 5) kHz

(30 to 10) kHz

Load Impedance

 100 k

 100 k

 5  non-inductive

Working/Common Mode Voltage

250 VAC/250 VAC

250 VAC/30 VAC

Output Termination

5 ft (1.5 m) lead with 4 mm safety banana plugs (2) 4 mm banana jacks

MECHANICAL

Jaw Opening

0.78 in (20 mm)

Maximum Conductor Size

0.47 in Ø max (12 mm)

Dimensions

(1.26 x 4.53 x 0.87) in (32 x 115 x 22) mm

Weight

5.6 oz (159 g)

Material

Polycarbonate UL 94

ENVIRONMENTAL

Operating Temperature

(14 to 122) °F (-10 to 50) °C

(-13 to 122) °F (-25 to 50) 0 °C

Storage Temperature

(-40 to 176) °F (-40 to 80) °C

SAFETY

Safety Rating

3 kV (50/60) Hz dielectric for 1 min Probes MN 103/114 and 185 are not CE marked

Consult factory for NIST Calibration prices

MN103
MN185
FEATURES
· Measurement range of 1 mA to 120 AAC · Jaw opening of 0.78 inch · Accommodates conductors up to
0.47 inch diameter · Ergonomic design and easy operation · Compact size accommodates hard to
reach locations · Low phase shift for power measurements · Available with mV or mA output signals · Constructed with UL94VO flame retardant
material · Designed for DMMs, recorders, loggers
and oscilloscopes

CATALOG NO. 1031.02 2110.71 100.185

DESCRIPTION AC Current Probe Model MN103 (10 A, 1 mV/mA & 100 A, 1 mV/A, Lead) AC Current Probe Model MN114 (10 A, 100 mV/A, Lead) AC Current Probe Model MN185 (100 A, 1 mA/A, Jack)

24 www.aemc.com

Technical Assistance (800) 343-1391
© Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved.

Vol. 23 Rev.00 02/2023

CURRENT MEASUREMENT PROBES
LM SERIES

MODELS LM102 & LM103
Equipped with high performance magnetic material offering excellent linearity and improved performance
Ideal current measurement tool for use with multimeters, data loggers and power analyzers

SPECIFICATIONS
MODELS ELECTRICAL Nominal Range
Measurement Range
Transformation Ratio
Output Signal
Phase Shift
Overload
Frequency Range Load Impedance Open Secondary Voltage
Output Termination
MECHANICAL Maximum Conductor Size Dimensions Weight Material ENVIRONMENTAL Operating Temperature Storage Temperature Operating Relative Humidity SAFETY
Safety Rating
Ingress Protection Consult factory for NIST Calibration prices

Patent #1385787 - Mini-Clamp Design

LM102

LM103

200 AAC

50 mA to 200 AAC (1  or 10  load)

100 mA to 200 A

1000:1

Voltage Output

1 mA/A (200 mAAC @ 200 A)

1 mV/A (200 mVAC @ 200 A)

 3 ° (1  load)  6 ° (10  load)

 3 °

350 A continuous @  1 kHz 200 A continuous @  8 kHz

48 Hz to 10 kHz

 10 

 10 k

 30 V

­

Double-insulated 5 ft (1.5 m) lead with (2) 4 mm safety banana plugs

Ø 0.63 in (16 mm)
(5.13 x 1.81 x 1.34) in (130 x 46 x 34) mm Approximately 8.8 oz (250 g) Polycarbonate UL 94
(14 to 122) °F (-10 to 50) °C (-40 to 176) °F (-40 to 80) °C (0 to 85) % RH decreasing linearly above 95 °F (35 °C)
EN 61010-1, EN 61010-2-031, EN 61010-2-032 600 V CAT III, 300 V CAT IV Pollution Degree 2 IP20 (EN 60529)

LM102
IP 20
FEATURES
· Clamping diameter 0.63 inch (16 mm) · Measurement range from
0.05 Amps to 200 Amps · Over range up to
350 Amps continuous · 1 mA/A output (Model LM102) · 1 mV/A output (Model LM103) · Clothes pin design allows access
to tight places · Frequency response from
48 Hz to 10 kHz · Arrow marker clearly assists in
proper orientation for power measurement applications

CATALOG NO. 2153.04 2153.05

DESCRIPTION AC Current Probe Model LM102 (200 A/1 mA/A) AC Current Probe Model LM103 (200 A/1 mV/A)

Vol. 23 Rev.00 02/2023

Technical Assistance (800) 343-1391
© Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved.

www.aemc.com 25

CURRENT MEASUREMENT PROBES
MN SERIES AC CURRENT PROBES

MN200 SERIES
General purpose AC current probe with voltage output, for use with DMMs or with measuring instruments with voltage input
Permits measurement or recording of current with instruments that do not have current ranges. Output signal proportional to current measured

SPECIFICATIONS
MODELS ELECTRICAL Nominal Range Measurement Range Transformation Ratio
Output Signal
Phase Shift (20 A Range)

MN255
20 AAC; 200 AAC (0.1 to 24) AAC; (0.1 to 240) AAC Voltage output 20 A: 100 mV/A (20 VAC @ 200 A) 200 A: 10 mV/A (2 VAC @ 200 A)
Not Specified

MN261

MN291

(0.1 to 24) A; (0.1 to 240) A
­ 100 mV/A (2 V @ 20 A), 10 mV/A AC (2 V @ 200 A)

200 AAC (0.5 to 240) AAC DC Voltage output
100 mVDC/AAC (20 VDC @ 200 A)

Not Specified

(200 A Range) 0.5 A to 10 A

Not Specified

Not Specified

­

10 A to 40 A

 5 °

 6 °

40 A to 100 A 100 A to 240 A

 3 °  2.5 °

 4 °  3 °

Overload

(24 and 240) A for 10 min ON, 30 min OFF

Frequency Range

40 Hz to 10 kHz (-3dB)

Load Impedance Working/Common Mode Voltage
Output Termination
MECHANICAL Jaw Opening Maximum Conductor Size Maximum Bus Bar size Dimensions Weight Material ENVIRONMENTAL Operating Temperature Storage Temperature Operating Relative Humidity SAFETY Safety Rating UL Approval Ingress Protection

> 1 M 600 V Double-insulated 5 ft (1.5 m) lead with (2) 4 mm safety banana plugs
0.83 in (21 mm) Ø 0.78 in max (20 mm) (0.78 x 0.19) in (20 x 5) mm (5.47 x 2.00 x 1.18) in (139 x 51 x 30) mm
6.5 oz (184 g) Polycarbonate UL 94
(14 to 131) °F (-10 to 55 ) °C (-40 to 158) °F (-40 to 70) °C
(10 to 90) % RH
EN/IEC 61010-2-32 600 V CAT III, EN/IEC 61010-032 Yes - United States and Canada IP40

Consult factory for NIST Calibration prices

MN255
IP 40
FEATURES
· Small compact size · Measurement ranges from 100 mA to 240 A · Frequency response to 10 kHz · UL approved for both United States and Canada · Designed to EN61010, 600 V CAT III · Jaw opening accommodates 250 kcmil cables · Constructed with UL94VO flame retardant
material · Double insulated construction

CATALOG NO. DESCRIPTION

2115.81

AC Current Probe Model MN255 (20 A, 100 mV/A & 200 A, 10 mV/A, Lead)

2115.82

AC Current Probe Model MN261 (20 A, 100 mV/A & 200 A, 10 mV/A, BNC)

2115.84

AC Current Probe Model MN291 (200 A, 100 mVDC/A, Lead)

26 www.aemc.com

Technical Assistance (800) 343-1391
© Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved.

Vol. 23 Rev.00 02/2023

CURRENT MEASUREMENT PROBES
MN SERIES AC CURRENT PROBES

MN300 SERIES

Compact sized probes ideal for measuring low currents and

leakage currents

MN307

Standard millivolt and milliamp outputs are compatible with multimeters, data loggers and oscilloscopes

SPECIFICATIONS

MODELS
ELECTRICAL
Nominal Range Measurement Range Transformation Ratio

MN307
10 AAC (0.1 to 12) AAC Voltage output

Output Signal

100 mV/A (1 VAC @ 10 A)

Phase Shift

(0.1 to 1) A:  5 ° (1 to 5) A:  3 ° (5 to 12) A:  2.5 °

Overload

20 A Continuous

Frequency Range

Load Impedance

1 M

Crest Factor

3 @ 10 Arms with an error (due to CF) of 3 %

Working/Common Mode Voltage

Output Termination

Double-insulated 5 ft (1.5 m) lead with (2) 4 mm safety banana plugs

MECHANICAL / ENVIRONMENTAL

Jaw Opening

Maximum Conductor Size

Dimensions

Weight

Material

Operating

Temperature Storage

Temperature Operating

Relative Humidity

SAFETY

Safety Rating

UL Approval

Consult factory for NIST Calibration prices

IP 40

MN312

MN352

MN353

MN375

MN379*

1000:1
1 mA/A (150 mAAC @ 150 A)

150 AAC (0.1 to 200) AAC
10 mV/A (1.5 VAC @ 150 A)

10 AAC (0.1 to 10) AAC
Voltage output
100 mV/A (1 VAC @ 10 A)

(0.1 to 1) A: Not specified (1 to 20) A:  3 ° (20 to 80) A:  2 °
(80 to 150) A: 2.5 ° (150 to 200) A: Not specified

(1 to 5) A:  1 ° @ 60 Hz
(5 to 10) A:  1.5 ° @ 60 Hz

200 A Continuous

240 A for 10 min ON, 30 min OFF

40 Hz to 10 kHz
1  3 @ 200 A peak
with an error (due to CF) of 3 %

3 @ 150 A peak with an error
(due to CF) of 3 %

600 Vrms

20 A Continuous
40 Hz to 3 kHz 1 M
3 @ 10 Arms with an error (due to CF) of 3 %

5 AAC; 100 AAC 5 mA to 6 AAC; (0.1 to 120) AAC
5 A: 200 mV/A (1 VAC @ 5 A) 100 A: 10 mV/A (1 VAC @ 100 A) (5 A Range) 5 mA: 6.5 ° 50 mA: 5 ° 0.5 A: 4.5 °
5 A: 4 ° (100 A Range)
0.1 A: 3.2 ° (1; 10; 100) A: 2.2 °
200 A Continuous
40 Hz to 10 kHz
Not specified

(2) standard safety 4 mm banana jacks

Double-insulated 5 ft (1.5 m) lead with (2) 4 mm safety banana plugs

0.83 in (21 mm) 0.78 in max (20 mm) (5.47 x 2.00 x 1.18) in (139 x 51 x 30) mm
6.5 oz (180 g) Polycarbonate UL 94 (14 to 131) °F (-10 to 55) °C
(-40 to 158) °F (-40 to 70) °C
85 % RH without roll-off above 95 °F (95 °C)
EN/IEC 61010-1 600 V CAT III, EN 61010-2-32, Pollution Degree 2 Yes - United States and Canada *(excludes MN379)

CATALOG NO. DESCRIPTION 2116.23 AC Current Probe Model MN307 (12 A, 100 mV/A, Lead) 2116.24 AC Current Probe Model MN312 (150 A, 1 mA/A, Jack) 2116.26 AC Current Probe Model MN352 (150 A, 10 mV/A, Jack)

CATALOG NO. DESCRIPTION 2116.27 AC Current Probe Model MN353 (150 A, 10 mV/A, Lead) 2115.41 AC Current Probe Model MN375 (10 A, 100 mV/A, Lead) 2153.01 AC Current Probe Model MN379 (5 A, 200 mV/A & 100 A, 10 mV/A, Lead)

Vol. 23 Rev.00 02/2023

Technical Assistance (800) 343-1391
© Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved.

www.aemc.com 27

CURRENT MEASUREMENT PROBES
MR SERIES AC/DC CURRENT PROBES

MODELS MR415 / 416 / 526
General Purpose Hall Effect Current Probes for use with DMMs, Data Loggers and Power Analyzers

SPECIFICATIONS

MODELS

MR415

MR416

MR526

ELECTRICAL Current Range Output Signal

(0.5 to 400) AAC, 600 ADC
1 mV/A

(0.5 to 40) AAC, 60 ADC
(0.5 to 400) AAC, 600 ADC
10 mV/A, 1 mV/A

(0.5 to 100) AAC, 150 ADC (0.5 to 1000) AAC, 1400 ADC
10 mV/A, 1 mV/A

Frequency Range
Phase Shift At (50/60) Hz
Load Impedance

DC to 30 kHz (-3 dB) (depending of current value)

 1.5 ° @ 400 A

 2.2 ° @ 40 A  1.5 ° @ 400 A

 2 ° @ 100 A  1.5 ° @ 800 A

> 1 M and  100 pF

Overload

3000 ADC or 1000 AAC continuous for < 1 kHz

Zero Adjust

Automatic on both ranges

Power Supply

9 V Alkaline battery (NEDA 1060A, 6LR61) or 5 V DC Micro-USB Type B

Battery Life

50 h typical

Low Battery Indication

Green LED blinking

Overload Indication

Red LED on when measurement > selected range

Output Termination

Double-insulated 5 ft (1.5 m) lead with (2) 4 mm safety banana plugs

MECHANICAL
Maximum Conductor Size
Dimensions (H x W x D) Weight (with Battery)

Cables: (1) 1.18 in (30 mm) or
(2) .94 in (24 mm)
Bus Bar: (1) (1.97 x 0.39) in (50 x 10) mm or (2) (1.23 x 0.39) in (31 x 10) mm or
(3) (0.98 x 0.31) in (25 x 8) mm
(8.82 x 3.82 x 1.73) in (224 x 97 x 44) mm
0.98 lb (444 g)

Cables: (1) 1.5 in (38 mm) or
(2) 1 in (25 mm)
Bus Bar: (1) (1.97 x 0.49) in (50 x 12) mm or
(2) (0.98 x 0.2) in (25 x 5) mm; (1) (1.24 x 0.30) in (31 x 8) mm or (3) (0.98 x 0.31) in (25 x 8) mm
(9.31 x 3.82 x 1.73) in (236 x 97 x 44) mm
1.15 lb (521 g)

ENVIRONMENTAL

Operating Temperature

(14 to +131) °F (-10 to 55) °C

Storage Temperature

(-40 to +176) °F (-40 to 80) °C

Relative Humidity

Up to 85 % RH @ 35 °C

SAFETY

Ingress Protection

IP40

EMC

EN 61326-1

Safety Rating

IEC 61010-1, EN 61010-2-32, Pollution Degree 2, 600 V CAT III

Consult factory for NIST Calibration prices

MR415

MR416

MR526

IP 40
FEATURES
· The jaw shape enables users to clamp on to cables or small bus bars
· Powered by battery or standard external 5 V power source via micro-USB connector
· Measures up to 1000 AAC and 1400 ADC (model dependent)
· Automatic Zero DC reset function
· Auto Power Off enable/disable function
· Millivolt output compatible with most equipment and instruments
· Battery life up to 50 hours
· Safety rating 600 V CAT III

4 mm Banana Plug Terminals

CATALOG NO. 1200.80 1200.82 1200.83

DESCRIPTION AC/DC Current Probe Model MR415 (400 AAC, 1 mV/A & 600 ADC, 1 mV/A, 4 mm Banana Plug Lead) - Replaces MR410 AC/DC Current Probe Model MR416 (40 AAC, 60 ADC, 10 mV/A & 400 AAC, 600 ADC, 1 mV/A, 4 mm Banana Plug Lead) - Replaces MR411 AC/DC Current Probe Model MR526 (100 AAC, 150 ADC, 10 mV/A & 1000 AAC, 1400 ADC, 1 mV/A, 4 mm Banana Plug Lead) - Replaces MR521

28 www.aemc.com

Technical Assistance (800) 343-1391
© Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved.

Vol. 23 Rev.00 02/2023

CURRENT MEASUREMENT PROBES
MR SERIES AC/DC CURRENT PROBES

MODELS MR417 / MR527
Hall Effect AC/DC current probes for Oscilloscopes and other instruments with waveform displays

SPECIFICATIONS

MODELS

MR417

MR527

ELECTRICAL

Current Range Output Signal

(0.5 to 40) AAC, 60 ADC (0.5 to 400) AAC, 600 ADC

(0.5 to 100) AAC, 150 ADC (0.5 to 1000) AAC, 1400 ADC

10 mV/A, 1 mV/A

Frequency Range
Phase Shift At (50/60) Hz

DC to 30 kHz (-3 dB) (depending of current value)

 2 ° @ 40 A  1.5 ° @ 400 A

 2.2 ° @ 100 A  1.5 ° @ 1000 A

Load Impedance

> 1 M and  100 pF

Overload

3000 ADC or 1000 AAC continuous for < 1 kHz

Zero Adjust

Automatic on both ranges

Power Supply

9 V alkaline battery (NEDA 1060 A, 6LR61) or 5 V DC Micro-USB Type B

Battery Life

50 hours typical

Low Battery Indication

Green LED blinking

Overload Indication

Red LED on when measurement > selected range

Output Termination

6.5 ft (2 m) coaxial cable with insulated BNC terminal

MECHANICAL

Maximum Conductor Size
Dimensions (H x W x D)

Cables: (1) 0.18 in (5 mm) or (2) .94 in (24 mm)
Bus Bar: (1) (1.97 x 0.39) in (50 x 10) mm or (2) (1.23 x 0.39) in (31 x 10) mm or
(3) (0.98 x 0.31) in (25 x 8) mm
(8.82 x 3.82 x 1.73) in (224 x 97 x 44) mm

Cables: (1) 1.5 in (38 mm) or
(2) 1 in (25 mm)
Bus Bar: (1) (1.97 x 0.49) in (50 x 12) mm or
(2) (0.98 x 0.2) in (25 x 5) mm; (1) (1.24 x 0.30) in (31 x 8) mm or (3) (0.98 x 0.31) in (25 x 8) mm
(9.31 x 3.82 x 1.73) in (236 x 97 x 44) mm

Weight (with Battery)

0.98 lb (440 g)

1.15 lb (521 g)

ENVIRONMENTAL

Operating Temperature

(14 to +131) °F (-10 to 55) °C

Storage Temperature

(-40 to +176) °F (-40 to 80) °C

Relative Humidity

Up to 85 % RH @ 35 °C

SAFETY

Ingress Protection

IP 40

EMC

EN 61326-1

Safety Rating

IEC 61010-1, EN 61010-2-32, Pollution Degree 2, 600 V CAT III

MR417

MR527

IP 40
FEATURES
· The jaw shape enables users to clamp on to cables or small bus bars
· Powered by battery or standard external 5 V power source via micro-USB connector
· Measures up to 1000 AAC and 1400 ADC (model dependent)
· Equipped with a Zero DC reset function
· Auto Power Off enable/disable function
· LED overload and low battery indicators
· Millivolt output compatible with most equipment and instruments
· Equipped with a coaxial lead and isolated BNC connectors for direct connection to an oscilloscope
· Battery life up to 50 hours
· Safety rating 600 V CAT III

BNC Connector

CATALOG NO. 1200.84 1200.85

DESCRIPTION AC/DC Current Probe Model MR417 (40 AAC, 60 ADC, 10 mV/A & 400 AAC, 600 ADC, 1 mV/A, BNC Output) Replaces MR461 AC/DC Current Probe Model MR527 (100 AAC, 150 ADC, 10 mV/A & 1000 AAC, 1400 ADC, 1 mV/A, BNC Output) Replaces MR561

Vol. 23 Rev.00 02/2023

Technical Assistance (800) 343-1391
© Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved.

www.aemc.com 29

CURRENT MEASUREMENT PROBES
MH SERIES

MODEL MH60
Designed to measure AC and DC currents using dual Hall effect and transformer technology at frequencies to 1 MHz
Self-powered directly from oscilloscope or line-power via line-adapter

SPECIFICATIONS
MODEL ELECTRICAL Nominal Range Measurement Range Transformation Ratio Output Signal Phase Shift Overload Frequency Range (@ -3 dB)
Load Impedance
Common Mode Voltage
Power Supply
Battery Life Output Termination MECHANICAL Maximum Conductor Size Dimensions Weight Material ENVIRONMENTAL Operating Temperature Storage Temperature Operating Relative Humidity SAFETY CE Mark Double Insulation Ingress Protection
Safety Rating

MH60
100 AAC/DC (140 A peak) 500 mA to 100 AAC / 100 ADC
Voltage Output 10 mV/A (1 VAC/DC @ 100 A)
 1 ° 150 A Continuous
DC to 1 MHz 0.25 m (at 400 Hz) 0.628 m (at 1 MHz) In RF: 0.1 µH for a primary transition
(600 V Max) At 50 Hz: 3.5 mA / 5 mA @ 100 V At 400 Hz: 25.9 mA / 50 mA @ 100 V Internal NiMH rechargeable battery; 5 VDC external via female micro-USB Type B connection 8 h typical with fully-charged battery 6.6 ft (2 m) lead with molded isolated male BNC connector
Ø 1.02 in (26 mm) (5.43 x 1.92 x 1.10) in (138 x 49 x 28) mm
Approximately 7.05 oz (200 g) Polycarbonate UL 94
(14 to 122) °F (-10 to 50) °C (-4 to 122) °F (-20 to 50) °C Up to 85 % RH decreasing linearly above 95 °F (35 °C)
Yes Yes IP40 (EN 60529) EN 61010-1 EN 61010-2-31 600 V CAT II, 300 V CAT III Pollution Degree 2

FEATURES
· Clamping diameter 1.02 in (26 mm) · Measurement range from
(0.5 to 100) Amps AC, 100 Amps DC · Measures AC and DC signals · 10 mV/A output · Automatic compensation for earth's
magnetic influence · Battery Power (8 hour battery life)
or USB continuous · Frequency response from DC to 1 MHz · Selectable 3 kHz or 30 kHz filter selection · Push button zero adjust · LED indicators for power, overload and
filter selection · UL 94 V2 self-extinguishing case material

CATALOG NO. 2153.03

DESCRIPTION AC/DC Current Probe Model MH60 (100 A, 1 MHz, BNC)

30 www.aemc.com

Technical Assistance (800) 343-1391
© Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved.

Vol. 23 Rev.00 02/2023

CURRENT MEASUREMENT PROBES
DIGITAL FLEXPROBE®
MODELS 400D & 4000D Provide a welcomed solution when accessing electrical conductors in tight places

MINIFLEX: 400D-10 (10 in probe)

MINIFLEX: 4000D-14 (14 in probe)

SPECIFICATIONS

MODELS

400D-10 & 400D-24

4000D-14 & 4000D-24

ELECTRICAL

Display Range

4 AAC, 40 AAC, 400 AAC

40 AAC, 400 AAC, 4000 AAC

Measurement Range

(0.020 to 3.999) A, (4.00 to 39.99) A (40.0 to 399.9) A

(0.20 to 39.99) A, (40.0 to 399.9) A, (400 to 3999) A

Resolution

1 mA, 10 mA, 100 mA

10 mA, 100 mA, 1 A

Sensor Diameter

400D-10: Ø 2.75 in (70 mm) 4000D-14: Ø 3.94 in (100 mm) 400D-24: Ø 8 in (203 mm) 4000D-24: Ø 8 in (203 mm)

Sensor Length

400D-10: Ø 10 in (254 mm) 4000D-14: Ø 14 in (355 mm) 400D-24: Ø 24 in (610 mm) 4000D-24: Ø 24 in (610 mm)

Bandwidth

10 Hz to 3 kHz

MECHANICAL

Power Supply

(2) 1.5 V AAA / LR3 batteries

Weight

Approx. 0.29 lb (132 g) MiniFlex

Casing Dimensions

(3.94 x 2.36 x 0.79) in (100 x 60 x 20) mm

Connection Cable Length

6 ft (1.8 m)

ENVIRONMENTAL

Operating Temperature

(32 to 122) °F (0 to 50) °C

SAFETY

Safety Rating

IEC 61010, 600 V CAT IV

Consult factory for NIST Calibration prices

PRODUCT INCLUDES
Digital FlexProbe®, (2) 1.5 V AAA batteries and user manual.

MINIFLEX: 400D-24 (24 in probe) 4000D-24 (24 in probe) (shown)
FEATURES
· Easy access and measurement, even in confined spaces
· Measurement from 20 mAAC to 4000 AAC (model dependent)
· Available with (10, 14 and 24) inch sensor lengths · Sensor diameter 2.75 in (70 mm) to 8 in (203 mm)
(model dependent) · Resolution down to 1 mA (model dependent) · HOLD feature · Direct reading · Compact and simple to use · Flexible current sensor · True RMS · Safety rating of 600 V CAT IV
ACCESSORIES
CATALOG #5000.44 MultiFix (universal mounting system) for use with models 5231, 5233, 400D, and 4000D

CATALOG NO. 2153.31 2153.36 2153.32 2153.35

DESCRIPTION Digital FlexProbe® Model 400D-10 w/6' Lead (TRMS, 4 AAC, 40 AAC, 400 AAC) Digital FlexProbe® Model 400D-24 w/6' Lead (TRMS, 4 AAC, 40 AAC, 400 AAC) Digital FlexProbe® Model 4000D-14 w/6' Lead (TRMS, 40 AAC, 400 AAC, 4000 AAC) Digital FlexProbe® Model 4000D-24 w/6' Lead (TRMS, 40 AAC, 400 AAC, 4000 AAC)

Vol. 23 Rev.00 02/2023

Technical Assistance (800) 343-1391
© Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved.

www.aemc.com 31

CURRENT MEASUREMENT PROBES
GENERAL PURPOSE PROBES SELECTION CHART

Series

Model MN01 MN02 MN05 MN09 MN103 MN114

Ratio

Measurement Range

AC

DC

Output Signal Current Voltage

1000:1 (2 to 150) A

1000:1

50 mA to 100 A 50 mA to 90 A

­

5 mA to 10 A (1 to 100) A

­ 1 mA/A*
­
­

­
­ 1 mV/mA 1 mV/A

­

(1 to 150) A

­

100 mVDC/AAC

­

1 mA to 10 A (1 to 100) A

­

1 mV/mA 1 mV/A

­ 1 mA to 10 A

­

100 mV/A

Phase Shift**
N/A N/A N/A N/A N/A < 8 °

Maximum Conductor Size
Ø Cable Bus Bar

0.39 in (10 mm)

N/A

0.39 in (10 mm)

N/A

0.39 in (10 mm)

N/A

0.39 in (10 mm)

N/A

0.47 in (12 mm)

N/A

0.47 in (12 mm)

N/A

Output Connec-
tion

Catalog No.

Leads 2129.17

Leads 2129.20

Leads 2129.19

Leads 2129.21

Leads 1031.02

Leads 2110.71

MN185 1000:1 50 mA to 120 A

­

1 mA/A

­

< 3.5 °

0.47 in (12 mm)

N/A

Jacks 100.185

MN255 ­

(0.1 to 24) A (0.1 to 240) A

­

100 mV/A 10 mV/A

< 2.5 °

0.78 in (20 mm)

N/A

Leads 2115.81

MN261 ­

(0.1 to 24) A (0.5 to 240) A

­

100 mV/A 10 mV/A

< 6 °

0.78 in (20 mm)

N/A

BNC 2115.82

MN291 ­ (0.5 to 240) A

­

100 mVDC/AAC N/A

0.78 in (20 mm)

N/A

Leads 2115.84

MN307 ­ 10 mA to 12 A

­

100 mV/A

< 2.5 °

0.78 in (20 mm)

N/A

Leads 2116.23

MN312 1000:1 (0.1 to 200) A

­

1 mA/A*

­

< 2.5 °

0.78 in (20 mm)

N/A

Jacks 2116.24

MN352 ­

­

(0.1 to 150) A

MN353 ­

­

< 2.5 °

0.78 in (20 mm)

N/A

Jacks 2116.26

10 mV/A

< 2.5 °

0.78 in (20 mm)

N/A

Leads 2116.27

MN373 ­

(0.1 to 24) A (0.1 to 200) A

­

1000 mV/A 10 mV/A

< 3 °

0.78 in (20 mm)

N/A

Leads 2116.28

MN375 ­ (0.1 to 10) A

­

100 mV/A

< 1.5 °

0.78 in (20 mm)

N/A

Leads 2115.41

MN379 ­

5 mA to 6 A (0.1 to 120) A

­

200 mV/A 10 mV/A

< 4 °

0.78 in (20 mm)

N/A

Leads 2153.01

MN379T ­

5 mA to 6 A (0.1 to 120) A

­

200 mV/A 10 mV/A

< 4 °

0.78 in (20 mm)

N/A

Lead w/ 2153.02 BNC

SL206

­

10 mA to 1.5 A 10 mA to 2 A 50 mA to 60 A 50 mA to 80 A

­

1 mV/mAAC/DC 10 mV/AAC/DC

< 1 °

0.46 in (12 mm)

N/A

Leads 1201.45

1.18 in

MD301 1000:1 (2 to 500) A

­

1 mVDC/AAC

N/A

(30 mm) (2 x 500)

(2.48 x 0.20) in (63 x 5) mm

Leads

1201.07

kcmil

*Output Protection for open secondary **Phase shift indicated at maximum rating
Note: Models MN103, MN106, MN114 & MN185 are not CE compliant. MN200 & MN300 series are UL approved except MN379. Consult factory for NIST Calibration price.

32 www.aemc.com

Technical Assistance (800) 343-1391
© Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved.

Vol. 23 Rev.00 02/2023

CURRENT MEASUREMENT PROBES
GENERAL PURPOSE PROBES SELECTION CHART

SERIES

MODEL RATIO

MEASUREMENT RANGE

AC

DC

OUTPUT SIGNAL CURRENT VOLTAGE

PHASE SHIFT**

MR415 ­ (0.5 to 400) A (0.5 to 600) A ­

1 mV/A  1.5 °

MR416 ­

(0.5 to 40) A (0.5 to 60) A (0.5 to 400) A (0.5 to 600) A

­

10 mV/A  2.2 ° 1 mV/A  1.5 °

MR526 ­

(0.5 to 100) A (0.5 to 150) A (0.5 to 1000) A (0.5 to 1400) A

­

10 mV/A  2 ° 1 mV/A  1.5 °

SR601 1000:1 (0.1 to 1200) A

­

1 mA/A* ­

< 0.5 °

SR604 1000:1 (0.1 to 1200) A

­

1 mA/A* ­

< 0.5 °

SR651 ­ (0.1 to 1200) A

­

­

1 mV/A < 0.5 °

SR701 1000:1 1 mA to 1000 A

­

1 mA/A* ­

< 0.7 °

SR704 1000:1 1 mA to 1000 A

­

1 mA/A* ­

< 0.7 °

SR752 ­ (0.1 to 1000) A

­

­

1 mV/A < 0.7 °

1 mA to 1 A

SR759

­

10 mA to 10 A (0.1 to 100) A

­

(1 to 1000) A

1000 mV/A

­

100 mV/A 10 mV/A

< 1 °

1 mV/A

MAXIMUM CONDUCTOR SIZE

Ø CABLE

BUS BAR

OUTPUT CONNEC-
TION

CATALOG NO.

1.18 in (30 mm)

2 bus bar

5 ft

(1.24 x 0.39) in (1.5 m) 1200.80

(31 x 10) mm Lead

1.53 in (39 mm)

2 bus bar

5 ft

(1.95 x 0.19) in (1.5 m) 1200.82

(50 x 5) mm Lead

1.53 in (39 mm)

2 bus bar

5 ft

(1.95 x 0.19) in (1.5 m) 1200.83

(50 x 5) mm Lead

2.05 in (52 mm)
2.05 in (52 mm)
2.05 in (52 mm)
2.05 in (52 mm)
2.05 in (52 mm)
2.05 in (52 mm)

(1.95 x 0.19) in (50 x 5) mm
(1.95 x 0.19) in (50 x 5) mm
(1.95 x 0.19) in (50 x 5) mm
(1.95 x 0.19) in (50 x 5) mm
(1.95 x 0.19) in (50 x 5) mm
(1.95 x 0.19) in (50 x 5) mm

Jacks Leads Jacks Jacks Leads Leads

2113.43 2113.44 2113.45 2116.29 2116.30 2116.32

2.05 in (52 mm)

(1.95 x 0.19) in (50 x 5) mm

Leads

2116.33

K100 ­ 0.1 mA to 3 A 0.05 mA to ± 4.5 A ­ 1 mV/mA N/A
0.18 in (4.5 mm) K110 ­ (0.1 to 300) mA (0.05 to ± 450) mA ­ 10 mV/mA N/A

N/A

Plugs 1200.67

N/A

Plugs 2111.73

LM102 1000:1 50 mA to 200 A

­

1 mA/A* ­

< 3 °

N/A

0.63 in

LM103 ­ (0.1 to 200) A

­

(16 mm)

­

1 mV/A < 3 °

N/A

*Output Protection for open secondary **Phase shift indicated at maximum rating
Note: All SR probes listed on this chart are UL approved, however not all SR series probes are UL approved; please consult factory. Consult factory for NIST Calibration price.

Leads 2153.04 Leads 2153.05

OUTPUT TERMINATIONS

Lead with BNC
Insulated 6.5 ft (2 m) coaxial cable with insulated BNC connector rated 600 Vrms

Jacks
Two standard safety banana jacks (4 mm)

Leads
Double/reinforced 5 ft (1.5 m) leads with 4 mm safety banana plug

Shrouded Banana Plugs Two 4 mm safety banana plugs; standard ¾ in (19 mm) spacing

Vol. 23 Rev.00 02/2023

Technical Assistance (800) 343-1391
© Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved.

www.aemc.com 33

AMPFLEX® AND MINIFLEX® PROBES - SELECTION CHARTS

SERIES

MODEL

RATIO MEASUREMENT RANGE OUTPUT SIGNAL

MF 300-10-2-10-HF

­

MF 3000-14-1-1-HF

­

MA114

­

300-24-2-10

­

1000-24-1-1

­

1000-24-2-1

­

1000-36-2-1

­

3000-24-1-1

­

3000-36-1-1

­

3000-24-2-1

­

3000-48-2-1

­

6000-36-2-0.1

­

30000-24-2-0.1

­

30 A / 300 A
3000 A
3 A / 30 A / 300 A / 3000 A
30 A / 300 A 1000 A
100 A / 1000 A 100 A / 1000 A
3000 A 3000 A 300 A / 3000 A 300 A / 3000 A 600 A / 6000 A 3000 A / 30,000 A

100 mV/A, 10 mV/A
1 mV/A
1 mV/mA, 100 mV/A 10 mV/A, 1 mV/A
100 mV/A, 10 mV/A 1 mV/A
10 mV/A, 1 mV/A 10 mV/A, 1 mV/A
1 mV/A 1 mV/A 10 mV/A, 1 mV/A 1 mV/A 1 mV/A, 0.1 mV/A 1 mV/A, 0.1 mV/A

MAXIMUM CONDUCTOR SIZE

CATALOG NO.

2.95 in (75 mm)

2126.84

3.93 in (100 mm)

2126.86

4 in (101 mm)

2153.41

7.48 in ( 190 mm) 7.48 in ( 190 mm) 7.48 in ( 190 mm) 11 in (280 mm) 7.48 in (190 mm) 11 in (280 mm) 7.48 in (190 mm) 15 in (381 mm) 11 in (280 mm) 7.48 in (190 mm)

2112.88 2112.39 2112.98 2113.00 2112.46 2112.48 2113.05 2112.01 2113.21 2113.33

24-3001

­

300 A / 3000 AAC

10 mV/A, 1 mV/A

7.48 in (190 mm)

2120.81

Consult factory for NIST Calibration price
OSCILLOSCOPE & BNC TERMINATED PROBES

MODEL

MEASUREMENT RANGE

AC

DC

SL261

Note: Consult factory for NIST1C0(a01libmtoraA1ti0oton0)1pA0ricAe

OUTPUT SIGNAL VOLTAGE
100 mV/A 10 mV/A

PHASE SHIFT*
< 1.5 °

MN261

(0.1 to 24) A (0.5 to 240) A

­

100 mV/A 10 mV/A

< 2.5 °

SR661
MN251T MN379T
MH60

(0.1 to 12) A

(0.1 to 120) A

­

(1 to 1200) A

(0.5 to 240) A

­

(0.005 to 6) A

­

(0.1 to 120) A

­

(0.5 to 100) A (0.5 to 100) A

100 mV/A 10 mV/A 1 mV/A
1 mV/A 200 mV/A 10 mV/A
10 mV/A

< 1 °
< 2.5 ° < 4 ° < 2.2 °
< 1 °

MR417 MR527

(0.5 to 40) A (0.5 to 60) A (0.5 to 400) A (0.5 to 600) A
(0.5 to 100) A (0.5 to 150) A (0.5 to 1000) A (0.5 to 1400) A

10 mV/A 1 mV/A
10 mV/A 1 mV/A

 2.2 °  1.5 °
 2.2 °  1.5 °

MAXIMUM CONDUCTOR SIZE

Ø CABLE

BUS BAR

0.46 in (12 mm)

N/A

OUTPUT CONNECTION
6.5 ft (2 m) Lead w/BNC

0.78 in (20 mm)

6.5 ft (2 m)

N/A

Lead

w/BNC

2.05 in (52 mm)

(1.96 x 0.19) in (50 x 5) mm

6.5 ft (2 m) Lead w/BNC

0.78 in (20 mm)
1.02 in (26 mm)
1.18 in (30 mm)
1.53 in (39 mm)

0.78 in (20 mm)

10 ft (3 m) Lead w/BNC

6.6 ft (2 m)

N/A

Lead

w/BNC

2 bus bar 6.6 ft (2 m) (1.24 x 0.39) in Lead (32 x 10) mm w/BNC

2 bus bar 6.6 ft (2 m) (1.96 x 0.19) in Lead (50 x 5) mm w/BNC

*Phase shift indicated at maximum rating. Note: All probes are rated 600 V CAT III and CE compliant. Not all models are UL approved; please consult factory. Consult factory for NIST Calibration price.

34 www.aemc.com

Technical Assistance (800) 343-1391
© Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved.

Vol. 23 Rev.00 02/2023

DATA LOGGERS

DATA ANALYSIS AND REPORTING SOFTWARE

SEE PAGE 133 FOR MORE INFO ON DATAVIEW® SOFTWARE

CONFIGURE DATA LOGGERS
MODELS L261, L452, L562, DL913-914
Print reports of all test results / Configure all data logger functions and parameters from a PC including sample rate, recording length, channel configuration and more / Create and store a library of configurations / Capture, display and analyze data in real-time on a PC

SEE WEBSITE FOR PRICING AND AVAILABILITY: WWW.AEMC.COM

DATA LOGGERS
SIMPLE LOGGER® II

600 VAC/AC+DC MODEL L261
One channel simple -logger for voltage measuring, monitoring and troubleshooting

SPECIFICATIONS

MODEL

L261

ELECTRICAL

Channels

One

Input Connection

Two recessed 4 mm safety banana jacks

Measurement Range

(0 to 600) VAC/AC+DC

Resolution

0.1 V

Accuracy (50/60) Hz

(0 to 5) V: unspecified (5 to 50) V: ± (0.5 % of Reading + 1 V) (50 to 600) V: ± (0.5 % of Reading + 0.5 V)

Input Impedance

40 M

Sample Rate

64 samples/cycle

Storage Rate

Programmable from 8 every s to 1 every d

Storage Modes Recording Length

Start/Stop, FIFO, Extended Recording Mode (XRMTM) and Alarm
15 min to 8 weeks, programmable using DataView®

Memory

240,000 measurements (512 kB) The recorded data is stored in non-volatile
memory and will be retained even if the battery is low or removed.

Communication

USB 2.0 optically isolated

Power Supply

(2) 1.5 V AA-cell alkaline batteries (included)

Battery Life

100 h to > 45 d (dependent on sample rate and recording length)

MECHANICAL

Dimensions

(4.94 x 2.75 x 1.28) in (125 x 70 x 32) mm

Weight (with battery)

6.4 oz (181 g)

Case

UL94-V0

Vibration

IEC 68-2-6 (1.5 mm, 10 Hz to 55 Hz)

Shock

IEC 68-2-27 (30 G)

Drop

IEC 68-2-32 (1 m)

Consult factory for NIST Calibration prices

PRODUCT INCLUDES
USB cable, (1) set of color-coded (red/black) leads and alligator clips and a thumb drive with DataView® software.

IP 40
FEATURES
· TRMS voltage recording up to 600 VAC/AC+DC · AC: 64 samples per cycle and DC: 8 samples per second · Programmable storage rates from 8 every second to
1 every day · 4 user selectable storage modes · Stores up to 240,000 measurements in non-volatile memory · Powered by standard alkaline batteries · Lightweight and compact · 5 LED indicators quickly and clearly display logger status · Includes FREE DataView® software for data retrieval,
real-time display, analysis and report generation · Optically isolated USB 2.0 communication cable included · EN 61010-1; 300 V CAT IV; 600 V CAT III
APPLICATIONS
· Surge and Sag recording · Long term supply monitoring · Industrial, commercial and residential monitoring · Monitor voltage harmonics · Find intermittent voltage problems · Machine monitoring

CATALOG NO. 2126.05

DESCRIPTION Simple Logger® II Model L261 (1-Channel, TRMS, 600 VAC/AC+DC, DataView® Software)

36 www.aemc.com

Technical Assistance (800) 343-1391
© Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved.

Vol. 23 Rev.00 02/2023

DATA LOGGERS
SIMPLE LOGGER® II TRMS VOLTAGE & CURRENT

MODEL L562

Two input channel logger capable of recording Arms, Vrms and VA

SPECIFICATIONS

MODEL

L562

ELECTRICAL

Channels

Two

Connection

Current Channel

Voltage Channel

Input Connection

BNC

Two recessed banana jacks

Input Range

(0 to 1) VAC (for use with current probes
with a voltage output)

(0 to 600) VAC

Resolution

0.1 mV

0.1 V

Accuracy ((50/60) Hz)

(0 to 10) mV unspecified

(0 to 5) V unspecified

(10 to 50) mV:

(5 to 50) V:

± (0.5 % of Reading + 1 mV) ± ( 0.5 % of Reading + 1 V)

(50 to 1000) mV:

(50 to 600) V:

± (0.5 % of Reading + 0.5 mV) ± (0.5 % of Reading + 0.5 V)

Input Impedance

800 k

40 M

Maximum Input Voltage

5 Vrms or ± 7.07 V peak

(1.2 x 600) V

Sample Rate

64 samples/cycle

Storage Rate

Programmable from 8 every s to 1 every d

Storage Modes Recording Length

Start/Stop, FIFO, Extended Recording Mode (XRMTM) and Alarm
15 min to 8 weeks, programmable using DataView®

IP 40
FEATURES
· 2 input channels · Voltage: (0 to 600) VAC TRMS · Current: compatible with AC current probes with voltage
outputs (see page 32 - sold separately) · 64 samples per cycle · Records Arms, Vrms & VA (VA displays in DataView® software) · 4 user selectable storage modes · Programmable storage rates from 8 every second to
1 every day · Stores up to 240,000 measurements in non-volatile memory · Powered by standard alkaline batteries · 5 LED indicators quickly and clearly display logger status · Includes FREE DataView® software for data retrieval,
real-time display, analysis and report generation · Optically isolated USB 2.0 communication cable included

Memory
Communication Power Supply Battery Life MECHANICAL

240,000 measurement (512 kB). The recorded data is stored in non-volatile memory and will be retained even if the battery is low or removed.
USB 2.0 optically isolated
(2) 1.5 V AA-cell alkaline batteries (included)
100 h to > 45 d (Dependent on sample rate and recording length)

· Complies with EN 61010-1; 300 V CAT IV; 600 V CAT III (a safety rated current probe is required)
APPLICATIONS
· Single phase power monitoring · Residential, commercial, industrial, troubleshooting · Find sags and surges / track energy usage

Dimensions

(5.38 x 2.75 x 1.28) in (137 x 70 x 33) mm

Weight (with battery)
Case

6.4 oz (181 g) UL94-VO

Vibration

IEC 68-2-6 (1.5 mm, (10 to 55) Hz)

Shock

IEC 68-2-27 (30 G)

Drop

IEC 68-2-32 (1 m)

Consult factory for NIST Calibration prices

· Start-Stop time stamping
PRODUCT INCLUDES
Set of color-coded (red/black) 5 ft voltage leads and alligator clips, USB cable, (2) 1.5 V AA batteries, printed quick start guide, USB drive with DataView® software.

PROBE MODEL NUMBER

CATALOG NUMBER

PROBE OUTPUT

PROBE RANGE

MAX RANGE FOR SLII

CABLE DIAMETER

BUS BAR OUTPUT SIZE CONNECTION

MN261

2115.82

100 mV/A / 10 mV/A (0.1 to 24) A / (0.5 to 240) A 10 A / 100 A 0.78 in (19.8 mm) N/A Lead w/BNC

MN379T

2153.02

200 mV/A / 10 mV/A

5 A / 100 A

0.78 in (19.8 mm) N/A

SR661

2113.49

1 mV/A 10 mV/A 100 mV/A

1000 A 100 A 10 A

2.13 in (54.1 mm)

N/A

SEE PAGE 32 FOR MORE COMPATIBLE CURRENT PROBES (SOLD SEPARATELY)

CATALOG NO. 2126.35

DESCRIPTION Simple Logger® II Model L562 (2-Channel, TRMS, Voltage & Current, DataView® Software)

Lead w/BNC Lead w/BNC

Vol. 23 Rev.00 02/2023

Technical Assistance (800) 343-1391
© Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved.

www.aemc.com 37

DATA LOGGERS
TWO-CHANNEL DC VOLTAGE, CURRENT, PULSE & EVENT

MODEL L452
Bluetooth-enabled logger and event counter that records DC voltage, DC current, (4 to 20) mA or pulse counts

Real-time display!

Powered by batteries or through a USB

SPECIFICATIONS
MODEL ELECTRICAL Channels Input Measurements Range Accuracy (% of Reading) Resolution Input Impedance Sample Rate
Sample Period
Storage Modes Recording Length Memory Communication
Power Supply
Battery Life MECHANICAL Dimensions Weight (with battery) Vibration Shock ENVIRONMENTAL Operating Temperature Humidity Ingress Protection

IP 20
with terminals

L452

DC Current (4 to 20) mA

Two*

Six-pin terminal strip

DC Voltage

Event

Pulse

100 mV, 1 V, 10 V

N/A

± (0.25 % + 5 ct)

± (0.5 % + 1 ct)

N/A

0.01 mA

0.1 mV, 1 mV, 10 mV

N/A

100 

1 M

N/A

5 samples/s

16 samples/s

100 samples/s

DC inputs: 200, 400, 600, or 800 ms; or from 1 to 60 s Pulse detection: 10 ms

Start/Stop (ends when memory is full or when the recording stop time is reached, whichever comes first)

10 min to 1 y, set via instrument front panel or through DataView®

32 MB internal Flash memory (up to 1024 logging sessions, 16 M samples)

Bluetooth 2.1, Class 1 or USB 2.0

External: via USB connector Internal: (2) AA NiMH rechargeable batteries (charges through USB port)

Up to 180 d (dependent on storage rate/recording length)

(1.28 x 2.58 x 5.4) in (32 x 65 x 137) mm 6.7 oz (190 g) with batteries
IEC 68-2-6 (1.5 mm, (10 to 55) Hz) IEC 68-2-27 (30 G)

(32 to 122) °F (0 to 50) °C (16 to 85) %
IP40 (instrument alone); IP20 (instrument with terminal strip)

*Both channels must have the same input type. Consult factory for NIST Calibration prices

PRODUCT INCLUDES
6 ft USB cable, US 120 V wall-to-USB plug, 6-pin screw terminal block, (2) AA rechargeable NiMH batteries, a printed quick start guide, a USB drive containing DataView® software and user manual.

38 www.aemc.com

Technical Assistance (800) 343-1391
© Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved.

Vol. 23 Rev.00 02/2023

DATA LOGGERS
TWO-CHANNEL DC VOLTAGE, CURRENT, PULSE & EVENT

FEATURES
· Multiple data input types. The L452 can log DC voltage, DC current, 4 mA to 20 mA, pulse counts, or events. Measurements can be performed directly on the instrument, or through a variety of sensors. This data is stored in the instrument's large 32 MB internal Flash memory.
· Expanded user interface. You can set up the instrument and view real-time measurement data through the front panel LCD screen and input buttons. The L452 features an on-board menu-based interface for navigating measurement data and selecting configuration options.
· Enhanced DataView® support. The instrument connects to a PC using either Bluetooth or USB. Once connected, logged data can be downloaded, analyzed, and formatted into reports using the DataView® Data Logger Control Panel. This Control Panel also enables users to change settings on the instrument, view real-time measurements, schedule recording sessions, and perform other configuration tasks.

FRONT PANEL & FUNCTIONAL DISPLAYS

Navigation button: Left
Power button: ON/OFF
INSTRUMENT CONFIGURATION
OL
1 24.5 mV 2 91.8 mV
Instrument configuration parameters can be set through the front panel interface.
ALARM TRIGGERS

Navigation button: Up
Navigation button: Right
Enter button Navigation button: Down
BLUETOOTH ENABLED/VISIBILITY
Bluetooth: Enabled Visibility: Visible
Enable and configure Bluetooth's functionality.
RECORDING SESSION

UPPER LIMIT: 50.00 degC
LOWER LIMIT: -10.00 degC
Allows you to set the upper and/or lower alarm trigger limits.
MIN/MAX MEASUREMENTS

RECORDING SESSIONS: 4 FREE MEMORY: 29.66 MB
Displays the number of recording sessions currently stored in memory. It also shows the amount of free memory left for storing
additional recording sessions.
EVENT MEASUREMENT DATA

CATALOG NO. 2153.51

1 2.54 m3/s

1

MAX

2.54 m3/s

2

MIN

0.22 m3/s

For analog input types, this screen displays the session's MIN/MAX measurement values for each channel.

For event input, the Channels 1 & 2 measurement graphic data screen appears.

DESCRIPTION Data Logger Model L452 (2-Channel, w/LCD, 100 mV/1 V/10 VDC, (4 to 20) mADC, Event & Pulse, DataView® Software)

Vol. 23 Rev.00 02/2023

Technical Assistance (800) 343-1391
© Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved.

www.aemc.com 39

DATA LOGGERS
THREE- AND FOUR- CHANNEL AC CURRENT

MODELS DL913 & DL914 Waterproof three and four channel

NEW DL914

AC current data loggers with flexible sensors

SPECIFICATIONS

MODELS

DL913 / DL914

ELECTRICAL

Channels

3 (DL913) / 4 (DL914)

Inputs Measurement Ranges
Accuracy ((50/60) Hz)
Resolution Frequency Storage Rate
Recording Length
Memory

MiniFlex®

300 AAC / 3000 AAC

300 A range

3000 A range

(0.50 to (90.0 to (4.00 to (90.0 to (0.900 to 99.99) A 360.0) A 99.99) A 999.9) A 3.600) kA
± (1 %r + 10 D) ± (1 %r + 4 D) ± (1 %r + 10 D) ± (1 %r + 5 D) ± (1 %r + 4 D)

0.01 A

0.1 A

0.01 A

0.1 A

1 A

(45 to 65) Hz ± 0.1 Hz
Normal recording mode: Once per second Extended recording mode: Four per aggregation period
Battery Power: 4 d with no missing samples (normal recording mode)
7 to 30 d depending on the selected aggregation period (extended recording mode) External Power: 365 d

Internal 8 GB

SAFETY

R ATIN G
FEATURES

with USB cap on and cover closed

· Simple-to-use, 3 (DL913) and 4 (DL914) channel AC current data loggers

· 4th channel for neutral current monitoring (Model DL914)

· Includes 3 (DL913) or 4 (DL914) integral 24-inch flexible current sensors

· Current measurements from 500 mA up to 3600 A

Communication Battery Charge Time Power Supply
Battery Life
MECHANICAL

USB, Wi-Fi via router (Ethernet), or Wi-Fi Direct
10 h maximum (Wi-Fi off)
Internal: 4.2 A·h NiMH rechargeable battery pack External: USB connection
Normal recording mode: 4 d Extended recording mode: 7 to 30 d* (*Depending on the selected aggregation period) Reference user manual for in-depth information on the battery life, aggregation period, storage interval, and recording modes.

Dimensions
Weight (with battery) Sensor/Cable Length
Max. Conductor

(5.9 x 5.9 x 3.57) in (150 x 150 x 91) mm w/o sensors
DL913: 2.2 lbs (1 kg) / DL914: 2.42 lbs (1.1 kg)
3 (DL913) or 4 (DL914) integral 24 in (610 mm) MiniFlex® probes with 6.5 ft (2 m) leads 7.64 in (194 mm)

Case

UL94-V0 Flame retardant

Vibration

IEC 68-2-6 (1.5 mm, (10 to 55) Hz)

Shock

IEC 68-2-27 (30 G)

Drop

IEC 68-2-32 (3.3 ft [1 m] in the most severe position without permanent mechanical damage or functional deterioration)

ENVIRONMENTAL
Operating/ Storage Temperature
Relative Humidity

(14 to 122) °F (-10 to 50) °C / (-40 to 158) °F (-40 to 70) °C
Operation: up to 85 % RH (non-condensing) Storage: up to 95 % RH

Consult factory for NIST Calibration prices

· LCD displays real-time measurements and parameters such as memory, power, and communication status
· Front panel navigation of configuration options and measurement screens
· Built-in web server for remote monitoring · Extended recording mode for increased battery life · Battery and/or USB powered options · Frequency measurements · Wi-Fi and USB communications · Waterproof IP67 rated (USB cap on, cover closed)
APPLICATIONS
· Single/Split-phase and 3- or 4-phase load monitoring · Neutral and ground current monitoring · Intermittent problem detection · Machine load monitoring / Load profiling · Fault current detection
PRODUCT INCLUDES
Includes small classic tool bag, 10 ft USB Type A to Type B cable, (4) stainless steel mounting brackets, (4) stainless steel M4 machine screws, USB power adapter, quick start guide, and USB thumb drive with DataView® software and user manual.

CATALOG NO.

DESCRIPTION

2153.61

Data Logger Model DL913 (3-channel, TRMS, MiniFlex® 300/3000 A, Wi-Fi, DataView® Software)

2153.62

Data Logger Model DL914 (4-channel, TRMS, MiniFlex® 300/3000 A, Wi-Fi, DataView® Software)

40 www.aemc.com

Technical Assistance (800) 343-1391
© Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved.

Vol. 23 Rev.00 02/2023

DATA LOGGERS
SIMPLE LOGGER® DATA LOGGERS

MODELS SL01 TO SL13 Small AC and DC simple loggers can be ready to go in minutes with just a few parameters to set up
MODELS SL20 & SL50 Log DC Current and Temperature

SL10

SL12

SL20

SL01
SPECIFICATIONS

MODELS VOLTAGE Range Resolution
Accuracy
Maximum Input Voltage Input Impedance
Power Supply
Power Consumption

SL01

SL10

SL11

SL12

SL13

(0 to 5) VAC
10 mV
± (0.5 % of Reading + 50 mV)*

± 100 mVDC
0.1 mV
± (0.5 % of Reading +
0.5 mV)*

± 1 VDC 1 mV ± (0.5 % of Reading + 5 mV)*
60 VDC

± 10 VDC
10 mV
± ( 0.5 % of Reading + 50 mV)*

± 50 VDC
50 mV
± (0.5 % of Reading + 250 mV)*

800 K
Internal: (2) 1.5 V AA non-rechargeable batteries External: USB 2.0 (computer or other USB power source)
Internal power: 1 mA (average) / External power: 100 mW

*Accuracy is specified with the 10-point filter selected to reduce noise. Consult factory for NIST Calibration prices

SL11
SL20 CURRENT ± 20 mA 0.02 mA ± (0.5 % of Reading + 0.1 mA)*
25 mADC
49 

SL13

SL50

IP 40
FEATURES
· Simple one button operation · Quick two wire input connection · User configurable scaling, units of
measure and recording length · Stores up to 4 million measurements · Data analysis software included · Software provides real-time trend graph display, data download, analysis and report generation · Micro-B USB cable included

MODEL
Range Resolution

Thermocouple Type:

J

K

TEMPERATURE

(-346 to 2192) °F (-328 to 2502) °F (-210 to 1200) °C (-200 to 1372) °C

N
(-328 to 2372) °F (-200 to 1300) °C

SL50
T
(-328 to 752) °F (-200 to 400) °C
0.1 °C

E
(-328 to 1832) °F (-200 to 1000) °C

R

S

(32 to 3200) °F (0 to 1760) °C

Accuracy

Below -148 °F (-100 °C): ± (0.4 % of Reading + 9 °F [5 °C])* (-148 to 212) °F (-100 to 100) °C: (0.3 % of Reading + 7.2 °F [4 °C])*

(32 to 212) °F (0 to +100) °C: ± (0.3 % of Reading + 18 °F [10 °C])*

Above 212 °F (100 °C): ± (0.2 % of Reading + 5.4 °F [3 °C])*

Above 212 °F (100 °C): ± (0.2 % of Reading + 14 °F [8 °C])*

Maximum Input Voltage
Input Impedance

1 V 800 K

Power Supply

Internal: (2) 1.5 V AA non-rechargeable batteries External: USB 2.0 (computer or other power source, when powered by the USB the battery is automatically disconnected)

Power Consumption

Internal power: 1 mA (average) / External power: 100 mW

*Accuracy is specified with the 10-point filter selected to reduce noise. Consult factory for NIST Calibration prices

Vol. 23 Rev.00 02/2023

Technical Assistance (800) 343-1391
© Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved.

www.aemc.com 41

DATA LOGGERS
SIMPLE LOGGER® DATA LOGGERS

SIMPLE LOGGER CONTROL PANEL
The Simple Logger Control Panel allows you to configure how data measured by these instruments is recorded and displayed. The available settings depend on which model is connected to the computer. The following table shows which configuration options are available for each model.

FEATURE

SL01 SL10 SL11 SL12 SL13 SL20 SL50

Set up recording

ó

ó

ó

ó

ó

ó

ó

Define units

ó

ó

ó

ó

ó

ó

ó

Set instrument clock

ó

ó

ó

ó

ó

ó

ó

Erase instrument memory

ó

ó

ó

ó

ó

ó

ó

Scaling

ó

ó

ó

ó

ó

ó

Filtering

ó

ó

ó

ó

ó

ó

ó

Thermocouple type

ó

Cold Junction Compensation

ó

Current configuration of a logger

Typical real-time trend graph

CATALOG NO. 2156.01 2156.10 2156.11 2156.12 2156.13 2156.20 2156.50

DESCRIPTION Simple Logger® Model SL01 (Low Voltage, 5 VAC) Simple Logger® Model SL10 (Voltage, 100 mVDC) Simple Logger® Model SL11 (Voltage, 1 VDC) Simple Logger® Model SL12 (Voltage, 10 VDC) Simple Logger® Model SL13 (Voltage, 50 VDC) Simple Logger® Model SL20 (Current, 4 to 20 mADC) Simple Logger® Model SL50 (Temperature, Thermocouple)

42 www.aemc.com

Technical Assistance (800) 343-1391
© Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved.

Vol. 23 Rev.00 02/2023

DIGITAL MULTIMETERS
SEE WEBSITE FOR PRICING AND AVAILABILITY: WWW.AEMC.COM

DIGITAL MULTIMETERS
5000 SERIES
MODELS 5212, 5217, 5231 & 5233 Compact and simple to use, these multimeters with a large backlit display and noncontact voltage detection are exceptional products and a great value for today's market

SPECIFICATIONS
MODELS GENERAL True RMS AC Bandwidth Auto/Manual Ranging LCD Display Auto/Manual Range Select Voltage AC/DC Current AC/DC
µAmps AC/DC Resistance Frequency/Duty Cycle
Capacitance
Temperature
Continuity with Beeper Diode Test V Low Z Non Contact Voltage Detection (NCV) Max / Min / Max-Min  REL OTHER FEATURES Display Hold Flashlight Backlight Removable Holster Magnetic Hanger Auto Power OFF Auto Power OFF Disable Power Supply Battery Life Low Battery Indication Direct Fuse Access Drop Resistant Operating Temperature Range Double Insulated WARRANTY/SAFETY Warranty Ingress Protection Safety
Consult factory for NIST Calibration prices

5212

5217

5231

5233

Yes

1000 Hz

Yes

4000-count

6000-count

6000-count + 61 segment bargraph

Yes

600 V

750 VAC / 1000 VDC

6 ranges / 60 mV to 1000 V; Resolution: 0.01mV

4 A / 10 A

6 A /10 A

With 1 mV/A clamp: 600 A 2 ranges / (6 to 10) A

Resolution: 0.1 A

Resolution: 0.001 A

400 / 4000 µA

600 / 6000 µA

­

40 M

60 M

6 ranges / 60 M; Resolution: 0.1 

­

1000 Hz/Yes

­

3 ranges: up to 3 kHz/Yes

100 mF

­

6 ranges / 1000 µF; Resolution: 0.01 nF

­

(-61 to 2192) °F

­

(4 to 1400) °F

(-55 to 1200) °C

(-20 to 760) °C

Yes

Yes

Yes

4 ranges / 60 mV to 1000 V; Resolution: 0.01 mV

Yes/Red flashing display with buzzer

Yes/Red display

No / No / No

Yes / Yes / Yes

No / No / No

Yes / Yes / No

No

Yes

No

Yes

Yes Yes Yes ­ in the holster
(2) 1.5 V AA 500 h
Yes ­ 6.56 ft (2 m) (-4 to 122) °F (-20 to 50) °C

Yes Yes ­ Blue/Red
Yes Yes
Yes Yes
Yes

No No No
9 V > 100 h
Yes ­ 3.28 ft (1 m) (32 to 122) °F (0 to 50) °C

3 y 600 V CAT III

2 y IP54
1000 V CAT III, 600 V CAT IV

44 www.aemc.com

Technical Assistance (800) 343-1391
© Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved.

Vol. 23 Rev.00 02/2023

DIGITAL MULTIMETERS
5000 SERIES

Non-contact detection of network voltage (NCV Function-AC only)

FUNCTIONAL DISPLAYS
Display Hold enabled
Relative mode active Auto measurement MAX, MIN or MAX minus MIN selected Auto Power OFF
Low battery indication

SAFETY

5212 & 5217

R ATIN G
5233

IP

MODELS 5231 & 5233

54

FEATURES

Analog & Digital display

· AC/DC current up to (10 or 600) A with a current clamp giving direct readings (Model 5231)
· High sensitivity with a resolution of 0.01 mV

MAX/MIN selected Relative mode active AC/DC voltage or current

· Withstands overloads up to 8000 V
· VLowZ function detects and eliminates ghost voltages by placing a burden on the circuit
· Multi-position mounting

Auto Range Display Hold enabled
Buzzer indication

· Battery life extended with "sleep mode" feature

· Backlight screen and flashlight (Models 5212 & 5217)

· Displays MAX, MIN and MAX-MIN (Models 5217; Model 5233 displays MAX & MIN only)

· Displays relative measurement (Models 5217 & 5233)

· Measures temperature (Models 5217 & 5233)

· Measures frequency and duty cycle (Models 5217 & 5233)

AC/DC voltage or current Diode test selected Continuity selected M, k: Decimal prefix Hz: Frequency selected
°F, °C: Temperature
%: Duty cycle selected A, V: Amps or Volts F: Farads for capacitance n, m, µ: Decimal prefix
°F, °C: Temperature
Units of measure Hz: Frequency selected Low battery indicator Auto Power OFF Diode test selected
PRODUCT INCLUDES
5212 & 5217 Soft carrying pouch, set of (2) color-coded (red/black) leads, (2) 1.5 V AA batteries and user manual. THERMOCOUPLE ADAPTER Included with Model 5217 5231 Soft carrying case, set of (2) 5 ft color-coded leads (red/black) with needle tip (1000 V CAT IV 15 A), and user manual. 5233 Soft carrying case, set of (2) 5 ft color-coded leads (red/black), adapter - banana (male) to mini (female) with K-type thermocouple, and user manual.

CATALOG NO.
2154.07 2154.09 2125.64 2125.65

DESCRIPTION
DMM Model 5212 (TRMS, 4000-cts, NCV, V, A, AC/DC, Ohm, Auto Hold) DMM Model 5217 (TRMS, 6000-cts, NCV, V, A, AC/DC, Ohm, T, Frequency, Auto Hold) DMM Model 5231 (TRMS, 6000-cts, V, AC/DC, Ohm, CT, NCV) DMM Model 5233 (TRMS, 6000-cts, V, A, AC/DC, Cap, Ohm, T, NCV)

Vol. 23 Rev.00 02/2023

Technical Assistance (800) 343-1391
© Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved.

www.aemc.com 45

DIGITAL MULTIMETERS

3000 SERIES

3Yr

MODELS MTX 3290 & 3291
A compact, rugged, comfortable to grip, waterproof (to IP67 standard) meter

SPECIFICATIONS
MODELS ELECTRIC
DC, AC & AC+DC Voltages

MTX 3290 60 mV to 600 V

MTX 3291 60 mV to 1000 V

Voltage DC Accuracy

± 0.3 %

± 0.05 %

AC & AC+DC Bandwidth

20 kHz

100 kHz

DC, AC & AC+DC Current

600 µA to 10 A / 20 A (30 s max) (MTX 3291)

Current DC Accuracy

± 0.08 %

Frequency

60 Hz to 600 kHz

Resistance

600  to 60 M

Audible Continuity

600  signal < 30  ± 5  < 5 V

Diode Test

3 V with 1 mV resolution

Capacitance

6 nF to 60 mF

Temperature Pt100/1000

(-328 to 1472) °F (-200 to 800) °C

Temperature K/J TC

­

OTHER FUNCTIONS

MIN/MAX/PEAK

Time/date-stamped MAX/MIN/AVG or PEAK ±, on all functions

Relative Mode (Rel)
PWM Filter
V-Output Clamp Function for Direct Reading Secondary Functions or Measurements

Relative value + measured reference value on secondary display (MTX 3291)
4th-order 300 Hz low-pass filter for measuring variable speed drives with asynchronous motors
Integration of the ratio: 1, 10, 100, 1000 mV/A
dBm and VA resistive power, +/- duty cycle, and pulse width (MTX 3291)

SPEC Mode

­

GRAPH

­

Center Zero

Selectable or automatic (MTX 3291) bargraph for VDC and ADC

Memory

­

GENERAL

Display

LCD with backlighting (MTX 3291) and digits 14 mm high; Dual-line 60,000 (MTX 3291) or 6000-count display

Communication

USB optical connector &

­

SX-DMM software

(included)

Power Supply

(4) AA batteries (included) or NiMH batteries

Environment

Storage: (-4 to 158) °F (-20 to 70) °C Operation:( 32 to 104) °F (0 to 40) °C

Dimensions

(7.72 x 3.54 x 1.85) in (196 x 90 x 47) mm

Weight

20 oz (570 g)

Consult factory for NIST Calibration prices

SAFETY R ATIN G

MTX 3290

MTX 3291
IP 67

MTX 3290 only
FEATURES
· Easy-to-read (2.75 x 2.04) in (70 x 52) mm backlit LCD screen
· On screen connection indicator
· Current: auto-ranging up to 10 A
· Secondary measurements in addition to the main measurement to facilitate analysis
· MIN/MAX and AVG data with relative time/datestamping and voltage and current peaks
· SX-DMM software for real-time processing of the data on a PC (MTX 3291)
· Powered by four standard AA batteries or four NiMH batteries rechargeable available with optional external charging module
PRODUCT INCLUDES
Set of color-coded (red/black) safety leads, set of (2) color-coded (red/black) test probes, (4) 1.5 V AA alkaline batteries (installed), multilingual operation instructions, quick start guide, and a USB drive with user manual. Model MTX 3291 also includes a soft carrying case, USB cable, and USB drive with SX-DMM software.

CATALOG NO. 2154.01 2154.02

DESCRIPTION DMM Model MTX 3290 (ASYC IV, TRMS, 6000-cts, Digital LCD) DMM Model MTX 3291 (ASYC IV, TRMS, 60,000-cts, USB, Backlit, Digital LCD)

46 www.aemc.com

Technical Assistance (800) 343-1391
© Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved.

Vol. 23 Rev.00 02/2023

DIGITAL MULTIMETERS

3000 SERIES

3Yr

MODELS MTX 3292B & 3293B

Portable multimeter measuring resistance, capacitance, temperature, duty cycle, pulse counts and frequency

MTX 3292B

MTX 3293B

SPECIFICATIONS

SAFETY

MODELS

MTX 3292B

MTX 3293B

ELECTRICAL

R ATIN G

DC, AC & AC+DC Voltages

100 mV to 1000 V

*

Voltage DC Accuracy

± 0.03 %

± 0.02 %

**

AC & AC+DC Bandwidth

100 kHz

200 kHz

DC, AC & AC+DC Current Current DC Accuracy

1000 µA to 10 A / 10 to 20 A (30 s max) ± 0.01 %

*Bluetooth Communication for Models 3292B-BT & 3293B-BT only **AndroidTM App available on Google Play for Models 3292B-BT & 3293B-BT

Frequency Resistance Audible Continuity
Diode Test

10 Hz to 5 MHz
100  to 100 M
1000  signal < 20  < 3.5 V Diode 0 to 2.6 V < 1 mA + Zener Diode or LED 0 to 20 V < 11 mA

FEATURES
MTX 3292B & MTX 3293B · Easy-to-read 320 x 240 pixel color matrix graphical
screen with black background

Capacitance Temperature Pt100/1000 Temperature K/J TC OTHER FUNCTIONS
MIN/MAX/PEAK
Relative Mode (Rel)
PWM Filter
V/A-Output Clamp Function for Direct Reading Secondary Measurements SPEC Mode

1 nF to 10 mF (-328 to 1472) °F (-200 to 800) °C (-40 to 2192) °F (-40 to 1200) °C
SURV time/date-stamped MAX/MIN/AVG or PEAK ± on all functions
Relative value REF-delta unit or on 3 displays + main measurement 4th-order 300 Hz low-pass filter for measuring variable speed drives with asynchronous motors
Programmable ratio
3 measurements + main measurement Display of measurement tolerance: Smin, Smax

· Trace, cursors and zoom on recordings · Programmable storage rate · Stores up to 30,000 measurements (MTX 3293B) · On screen connection indicator · USB or Bluetooth Class II communication available
as an option · NiMH AA rechargeable battery · No downtime: instrument operates while charging
PRODUCT INCLUDES
MTX 3292B & MTX 3292B-BT, MTX 3293B & MTX 3293B-BT

GRAPH Center Zero Memory GENERAL
Display

Trends of main measurements < 60 s + Zoom + Cursor Automatic trend bargraph
10,000 measurements 30,000 measurements
Color graphical display (70 x 52) with backlighting on four-line 100,000-count display

Soft carrying case, set of (2) color-coded (red/black) safety leads, set of (2) color-coded (red/black) test probes, printed quick start guide, (4) NiMH 2400 mA·h 1.5 V rechargeable batteries (installed), optical USB cable, USB Type A charger, USB charging cable and USB drive with SX-DMM software.

Communication

USB optical connector or Bluetooth Class II (optional) & SX-DMM software (included)

Power Supply

Charger or (4) AA batteries or NiMH batteries (included)

Environment

Storage: (-4 to 158) °F (-20 to 70) °C Operation: (32 to 104) °F (0 to 40) °C

Dimensions

(7.72 x 3.54 x 1.85) in (196 x 90 x 47.1) mm

Weight

20.1 oz (570 g)

Consult factory for NIST Calibration prices

SHOWN: MTX 3293B

CATALOG NO.
2154.03 2154.04 2154.05 2154.06

DESCRIPTION
DMM Model MTX 3292B (ASYC IV, TRMS, 100,000-cts, USB, Color Graphical Display) DMM Model MTX 3293B (ASYC IV, TRMS, 100,000-cts, USB, Color Graphical Display) DMM Model MTX 3292B-BT (ASYC IV, TRMS, 100,000-cts, Bluetooth, USB, Color Graphical Display) DMM Model MTX 3293B-BT (ASYC IV, TRMS, 100,000-cts, Bluetooth, USB, Color Graphical Display)

Vol. 23 Rev.00 02/2023

Technical Assistance (800) 343-1391
© Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved.

www.aemc.com 47

DIGITAL MULTIMETERS
3000 SERIES
FUNCTIONAL DISPLAYS The TRMS measurements of AC voltages and currents are also accurate on non-linear signals
MTX 3292B & MTX 3293B COLOR MATRIX GRAPHICAL SCREENS

SETUP MENU Configuration of measurements

MEASUREMENT
Configuration of the measurement parameters

MEM Storing of the measurements recording mode

HOLD Management and hold of the display

MTX 3290 & MTX 3291 BACKLIT LCD SCREENS

MAX/MIN AVG
Displays maximum, minimum and average values

PEAK MODE
Example of screen showing Peak+value

REL MODE
Displays relative values with respect to referenced measured value

48 www.aemc.com

Technical Assistance (800) 343-1391
© Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved.

Vol. 23 Rev.00 02/2023

ELECTRICAL TEST TOOLS
SEE WEBSITE FOR PRICING AND AVAILABILITY: WWW.AEMC.COM

ELECTRICAL TEST TOOLS
PHASE AND MOTOR ROTATION METERS

MODELS 6608, 6609 & 6610
Ideal for installing rotating machinery or motors, and checking generator output phase direction

SPECIFICATIONS

MODELS

6608

6609

6610

ELECTRICAL
Operating Voltage
Frequency Range Power Supply MECHANICAL Dimensions Weight

(40 to 850) VAC between phases

With leads connected: (40 to 600) VAC between phases

(75 to 1000) VAC Static induction

(15 to 400) Hz

(45 to 65) Hz

Self-powered via the measurement inputs

(1) 9 V Alkaline battery (included)

(5.1 x 2.7 x 1.3) in (130 x 69 x 33) mm

4.5 oz (128 g)

6 oz (170 g)

(5.0 x 2.8 x 1.8) in (127 x 71 x 46) mm
13.4 oz (380 g)

ENVIRONMENTAL
Operating Temperature
Storage Temperature
SAFETY
Safety Rating / Ingress Protection
Electrical Safety

(32 to 104) °F (0 to 40) °C
(-4 to 122) °F (-20 to 50) °C;
< 80 % RH
IEC 61010-1, DIN VDE 0411; IEC 61557-7, DIN VDE 0413-7;
Tightness / IP40
600 V CAT III

(14 to 122) °F (-10 to 50) °C; max. 80 % RH (-4 to 140) °F (-20 to 60) °C; max. 80 % RH
EN 61010-1, EN 61326-1
1000 V CAT III; 600 V CAT IV

PRODUCT INCLUDES
6608 & 6609
Soft carrying case, (3) 4 ft color-coded (red/black/blue) test leads, (3) color-coded (black) alligator clips and user manual.
6610
Soft carrying case, meter with attached test leads (black, red & blue) with alligator clips, 9 V battery and user manual.

6608 case

6610 case

6608

6609

6610

SAFETY
IP 40
R ATIN G
6610 only Except 6610
FEATURES
· Voltage sensing detector clips ­ no metal contact points to promote greater safety (Model 6610)
· Indication of live phase presence or phase absence
· Designed for checking a wider range of 3-phase power supply from 75 VAC to 1000 VAC (Model 6610)
· Determination of a motor's rotation direction (Model 6609)
· Automatic testing as soon as the instrument is connected
· Terminals and cables identified by color-coding to simplify connection (test leads are attached to Model 6610)
· Phase rotation indicators (Model 6608)
· Phase and motor rotation indicators (Models 6609 & 6610)
· Color-coded leads (red, black, blue) and alligator clips (black)
· Color-coded jacks for common U.S. phase colors
· Line supplied - no battery needed (Model 6608)
· Protected internally by high impedance circuit to limit the current to user safe limits

CATALOG NO.
2121.10 2121.11 2121.12

DESCRIPTION
Phase Rotation Meter Model 6608 Phase & Motor Rotation Meter Model 6609 Phase Rotation Meter Model 6610 (Non-contact)

50 www.aemc.com

Technical Assistance (800) 343-1391
© Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved.

Vol. 23 Rev.00 02/2023

ELECTRICAL TEST TOOLS
SPLITTER, TESTER AND DETECTOR
AC LINE SPLITTER
MODEL ALS-1 For use with clamp-on meters and multimeters using current probes
FEATURES
· Avoids splitting lines - makes reading current easy · Increases sensitivity of clamp-on current probes
and clamp-on meters ten times in X10 mode · Direct reading X1 mode · Voltmeter input jacks · Integral ground conductor · Facilitates reading current draw of device
plugged into it · Facilitates reading current draw through
extension cords · 120 V, 15 A capacity

NON-CONTACT AC VOLTAGE DETECTOR
MODEL NC-1

SPECIFICATIONS

MODEL

NC-1

Voltage Sensitivity

(120 to 240) VAC

Frequency

(50/60) Hz

Detection Distance

< 5 mm

Over Voltage

600 V CAT III

Power Supply

(2) 1.5 V AAA Alkaline (included)

Electrical Safety

For indoor use and in accordance with over voltage 600 V CAT III, Pollution Degree 2

ALS-1 NC-1

CATALOG NO.
2121.05 2121.09

DESCRIPTION
AC Line Splitter Model ALS-1 Non-Contact AC Voltage Detector Model NC-1

Vol. 23 Rev.00 02/2023

Technical Assistance (800) 343-1391
© Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved.

www.aemc.com 51

ELECTRICAL TEST TOOLS
NON-CONTACT HIGH VOLTAGE DETECTOR

MODEL 275HVD
Warns the operator of live conductors with the use of its detection sensor

SPECIFICATIONS

MODEL

275HVD

ELECTRICAL

Detection Frequency

(45 to 70) Hz

Ranges Detection

240 V, 2 kV, 6 kV, 11 kV, 22 kV, 33 kV, 132 kV, 275 kV
Selection range is detected at approximately 10 in (25 cm) from the voltage. Greater detection
distances can be obtained at lower voltage positions

Power Supply

(3) 1.5 V C cell batteries (included)

MECHANICAL

Self Test

User selectable

Indicators

Bright red LED and audible buzzer

ENVIRONMENTAL

Operating Temperature

(5 to 130) °F (-15 to 55) °C

Storage Temperature

(-4 to 150) °F (-20 to 65) °C

Humidity

Up to 93 % RH @ 104 °F (40 °C)

Electrical Safety

EN 61326-1, EN 61000-4-2, EN 61000-4-3, EN 55011

IP 65
Note: Not designed to work on shielded cable or enclosure.

FEATURES
· Non-contact high voltage detector · Wide range of detection; 80 V to 275 kV; one instrument fits
all applications · Eight switch-selectable voltage sensitivity ranges · Audible and visual (LED) indication of live voltage · Self-test ensures that all system functions and indicators
are working properly by energizing the complete system · Designed for use with hot sticks incorporating a shotgun adapter · Lightweight, minimizes sway at the end of long hot sticks · Suitable for indoor and outdoor use · Easy access to batteries
PRODUCT INCLUDES
Hard carrying case, universal spline for hot stick connection, (3) C cell batteries, shotgun adapter and a user manual. Note: Hot stick not supplied

ACCESSORIES/ REPLACEMENTS
Catalog #5100.03
Battery housing with o-ring and spring Catalog #5100.08
Metal Universal Spline Adapter Catalog #2131.36
Replacement Carrying Case

CATALOG NO. 2131.12

DESCRIPTION Non-Contact High Voltage Detector Model 275HVD (240 V to 275 kV, Manual self-test)

52 www.aemc.com

Technical Assistance (800) 343-1391
© Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved.

Vol. 23 Rev.00 02/2023

ELECTRICAL TEST TOOLS
VOLTAGE ABSENCE TESTERS (VATs)

MODEL CA 773
An essential tool for electricians to ensure no voltage is present before working on any electrical installation connected to the network

SPECIFICATIONS

MODEL

ELECTRICAL

Display

Voltage Absence Testing (VAT)

Voltage

LEDs

CA 773
LEDs + backlit digital display 12 VAC  U  1000 VAC; 12 VDC  U  1400 VDC
(12 to 1000) VAC; (12 to 1400) VDC

LEDs + backlit digital display
Frequency Impedance Max. Peak Current Polarity Indication Redundant Hazardous Voltage Indication
Stray Voltage Detection GFI Tripping
Phase/Neutral Identification
CONTINUITY & RESISTANCE Buzzer Trigger Threshold Extended Continuity Test (Resistance) Test Current / Open-circuit Voltage Phase Rotation Ph/Ph Voltage Buzzer
Electrical Safety Operating Temperatures Power Supply Environment Dimensions Weight

(1.0 to 299.0) VAC/DC (300 to 1,000) VAC / 1,400 VDC
DC, (16.67 to 800) Hz > 500 k
3.5 mA RMS Yes
The ELV (Extra-Low Voltage) LED indicates that the voltage is higher than the SELV (Safety Extra-Low Voltage) with rate at flashing proportional to the voltage level Yes (by low-impedance load switching) Up to 30 mA Above 50 V (45 to 65) Hz; Above 150 V (16.67 to 45) Hz
100  typical (150  max.) 0.5  to 2999 k  1 mA /  3.3 V
2-wire method with microprocessor 50 V  U  1000 VAC (45 to 400) Hz Intermittent beep for Voltage Detection
Continuous beep for continuity IEC 61243-3, EN 61243-3, IEC 61010 1000 V CAT IV
(5 to 113) °F (-15 to 45) °C (Class N) (2) AA batteries (included) or NiMH batteries
Storage: (-40 to 158) °F (-40 to 70) °C (7.72 x 3.54 x 1.85) in (196 x 90 x 47) mm
1.25 lb (567 g)

PRODUCT INCLUDES
Set of removable test probes Ø 2 mm with crystal safety cover, probe-tip protector, velcro strap, (2) 1.5 V AA batteries, and a multilingual user manual.

CA 773
IP 65
FEATURES
· Full autotest · Voltage detection, LED display:
12 VAC  U  1000 VAC 12 VDC  U  1400 VDC · Frequency: DC, (16.67 to 800) Hz · Detection of stray voltages · Unipolar phase detection (a single contact) · Two-pole phase-sequence testing with 2-wire method = a third hand is not required · Continuity test with audible and visual indication (R < 100 ) · Extended continuity test with visual indication for: R < 0.5  to 2.999 k · RCD trip test · Complies with EN 61243-3 & IEC 61010 1000 V CAT IV · Battery life > 2500 x 10 s measurements · Removable lead and test probe · Delivered complete and ready to use

CATALOG NO. 2121.15

DESCRIPTION Voltage Tester Model CA 773 (LED & backlit display, VAT 12 VAC  U  1000 VAC; 12 VDC  U  1400 VDC, Absence of Voltage)

Vol. 23 Rev.00 02/2023

Technical Assistance (800) 343-1391
© Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved.

www.aemc.com 53

ELECTRICAL TEST TOOLS
TACHOMETERS

MODELS CA 1725 & CA 1727
Simple to use and offers numerous measurement capabilities with or without contact

SPECIFICATIONS

MODELS

CA 1725

CA 1727

MEASUREMENTS

Rotational Speed Function

Range: (6 to 100,000) RPM Resolution: (0.0006 to 6) RPM depending on range

Linear Speed Function

Range: (0.1 to 10,000) m/min or ft/min Resolution: (0.0006 to 6) m/min or ft/min depending on range

Frequency Function

Range: (0.1 to 10,000) Hz Resolution: (0.0004 to 0.4) Hz depending on range

Period Function

Range: (0.1 to 10,000) ms Resolution: (0.0003 to 0.3) ms depending on range

Duty Cycle Function

Range: (10 to 10,000) % Resolution: (0.1 to 1) % depending on range

Count Function

Range: 0 to 99,999 events; Accuracy: ± 1 event (Model CA 1727)

GENERAL

Power Supply

9 V Alkaline battery (included)

Battery Life

250 x 5 min measurements with optical sensor; 600 x 5 min measurements with external sensor

Data Storage

4000 measurements (Model CA 1727)

Dimensions

(8.5 x 2.83 x 1.85) in (216 x 72 x 47) mm

Weight

8.8 oz (250 g)

Weatherproofing

IP51

Environment

Storage: (-4 to 158) °F (-20 to 70) °C 95 % RH; Operation: (32 to 131) °F (0 to 55) °C 90 % RH

OPTICAL SENSOR

Reflective Area

(10 to 90) % of the target area

Measurement Distance

(0.4 x 19.7) in (1 to 50) cm The maximum distance is given for a reflective adhesive strip with a minimum area of 10 cm2.

Measurement Angle

± 15 ° in relation to the perpendicular of the reflective surface.

MECHANICAL

Adapter
Pressure on Moving Part
Service Life

End-fittings: elastomer with a durometer hardness of 80 Between 2 and 40 N; maximum speed: 10,000 RPM Approx. 1000 h at 3000 RPM with a pressure of 20 N

Conical End-fitting Accessory

Minimum diameter of measurement shaft: 0.2 in (5 mm)

Cylindrical End-fitting Accessory

Speed measurements on shafts with a diameter greater than 0.2 in (5 mm) or flat-ended shafts

End-fitting Accessory with Wheel

Wheel diameter: 1.19 in (30 mm); Wheel development: 3.94 in ± 0.004 in (99 mm ± 0.1 mm)

Consult factory for NIST Calibration prices

IP 51

CA 1725

CA 1727

FEATURES
· Measurements up to 100,000 RPM
· Multiple functions and automatic routines for data acquisition and storage: measurement of rotational speed, linear speed, count, frequency and period
· Extensive programming possibilities
· Digital display with analog bargraph
· USB interface for processing results on a PC (Model CA 1727)
· Includes TachoGraph software on CD-ROM (Model CA 1727) download memory only
· Stores up to 4000 measurements results (Model CA 1727)

ACCESSORIES
MECHANICAL ACCESSORIES KIT Catalog #1749.02 Mechanical adapter, calibrated wheel, conical and cylindrical end fitting

PRODUCT INCLUDES
Hard case, FRB F connector, 9 V battery, set of (15) reflective strips, quick start guide and user manual.
CA 1727 also includes a USB cable and TachoGraph software.

CATALOG NO. 1748.10 1748.30

DESCRIPTION Tachometer Model CA 1725 Tachometer Model CA 1727

54 www.aemc.com

Technical Assistance (800) 343-1391
© Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved.

Vol. 23 Rev.00 02/2023

EELNEVCITRRIOCNALMTEESNTTTAOLOLTSESTERS

DATA ANALYSIS AND REPORTING SOFTWARE

SEE PAGE 133 FOR MORE INFO ON DATAVIEW® SOFTWARE

CONFIGURE ENVIRONMENTAL TESTERS
MODELS 1110, 1246, 1510, 1821, 1822 & 1823
Capture and display data in real-time / Configure all user selectable functions and parameters / Download and analyze stored data Create customizable reports / Print reports of all test results

SEE WEBSVoIlT. 2E3 ReFv.0O0 02R/202P3 RICINGTeAchNnicaDl AsAsisVtaAncIeL(8A00)B34I3L-1I3T91Y: WWW.AEwMww.Caem.Cc.cOomM 55
© Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved.

ENVIRONMENTAL TESTERS
LIGHTMETER

MODELS CA811 & CA813
Features optical sensors that are designed to match the response of the human eye

SPECIFICATIONS

MODELS

CA811

CA813*

MEASUREMENTS

Range

20 fc, 200 fc, 2000 fc, 20 kfc

20 lx, 200 lx, 2000 lx, 20 klx

20 lx, 200 lx, 2000 lx, 20 klx, 200 klx

Display Resolution

0.01 fc or 0.01 lx

Sensor

Silicon photodiode

Spectral Response

CIE Photopic Curve

Accuracy 2856 K Light Source Common Light Source

± 5 % of Reading ± 10 cts ± 5 % of Reading ± 10 cts ± 18 % of Reading ± 2 cts ± 11 % of Reading ± 2 cts

Sample Rate

2.5 times per s, nominal

GENERAL Display Operating Temperature
Storage Temperature
Polarity Power Supply Low Battery Indication Dimensions
Weight

3½ digit liquid crystal display (LCD), 2000-count

(32 to 122) °F (0 to 50) °C, < 80 % RH

(-4 to 140) °F (-20 to 60) °C, (0 to 80) % RH without battery

Automatic

(1) 9 V Alkaline battery (included)

Displayed when battery voltage is low

(6.81 x 2.38 x 1.5) in (173 x 60 x 38) mm

Approx. 7.55 oz (214 g) including battery

Approx. 7.9 oz (224 g) including battery

Consult factory for NIST Calibration prices

CA811

CA813

FEATURES
· Easy one-hand operation · Designed to measure a wide range
of lighting types · Removable sensor for remote reading · Measures in foot-candles (fc) or lux (lx) · Measures incandescent lighting · Cosine corrected · Hold function · Max function (CA811) · Peak function (CA813) · CIE photopic (human eye) response · 2000-count backlit LCD · Lightweight and compact · Removable protective sensor cover · Includes rugged, shockproof, protective
and dirt resistant gray cover

*Note: Model CA813 offers higher sensitivity (200 klx) and has a better spectral response to common light sources. Model CA811 is used to measure incandescent lighting.
PRODUCT INCLUDES
Rugged shockproof protective holster, 9 V battery and user manual.

APPLICATIONS
· Testing for OSHA compliance in workplace, cleanroom and industrial settings
· Ambient testing for light-sensitive displays and archives in museums and art galleries

CATALOG NO. 2121.20 2121.21

DESCRIPTION Lightmeter Model CA811 Lightmeter Model CA813

56 www.aemc.com

Technical Assistance (800) 343-1391
© Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved.

Vol. 23 Rev.00 02/2023

ENVIRONMENTAL TESTERS
AIR QUALITY

MODEL 1510 Monitor CO2, temperature, and humidity for a healthy environment
Assists with the prevention of COVID 19 by testing indoor air quality. Contact us to learn more.

SPECIFICATIONS

MODEL

1510

CO2 MEASUREMENT

Measuring Principle

Non-dispersive infrared (NDIR) technology

Type of Sensor

Double-beam infrared cell sensor

Measurement Range

(0 to 5000) ppm

Accuracy (CO2)

± 50 ppm ± 3 % of value measured

Response Time (63 %)

< 200 s

Resolution

1 ppm

TEMPERATURE MEASUREMENT

Type of Sensor

CMOS

Units

°C or °F

Measurement Range

(14 to 140) °F (-10 to 60) °C

Accuracy

± 0.1 °F (± 0.5 °C)

Resolution

0.1 °F (0.1 °C)

HUMIDITY MEASUREMENT

Type of Sensor

Capacitive

Measurement Range

(5 to 95) % RH

Accuracy

± 2 % RH

Resolution GENERAL

0.1 % RH

Recording Interval Storage Alarm

Programmable from 1 min to 2 h > 1 million measurements Yes

Backlighting Hold, Min & Max

Blue - red when in alarm condition Yes

Auto Power OFF

Yes (in portable mode only)

Dimensions / Weight Power Supply Communication

(4.92 x 2.58 x 1.26) in (125 x 65 x 32) mm / 6.7 oz (190 g) with batteries
Alkaline batteries: (2) AA or rechargeable battery connection to 120 V 60 Hz line / USB to wall adapter
Bluetooth (Class I) wireless communication / USB link; the product is then recognized as a USB drive for easy file transfer

Mounting DataView® Software

Optional padlock wall mount (padlock is not included), optional desktop stand and wall mount holster
Graphic representation or as table of values, data export, real-time mode calculation of the confinement index with
selection of presence periods & report generation

SAFETY

Safety Rating Ingress Protection

IEC 61010-1, 50 V CAT II ­ IEC 61326-1 IP40

Consult factory for NIST Calibration prices

CATALOG NO.

DESCRIPTION

CATALOG NO.

2138.08

Air Quality Logger Model 1510 (Gray) 2138.09

IP 40
FEATURES
· CO2, temperature, and humidity logger · Free app for AndroidTM from the Google® Play Store · Display turns red when any of the measurements
are in alarm condition · Compact and stand-alone: for mounting or portable use · User-friendly: comfort indicators based on the CO2,
temperature and humidity levels · Accurate: complies with the latest standards
concerning air quality monitoring · Quick, simple data download using supplied
DataView® software · On-site calibration test module with adapter, tube
and software for adjusting the zero and thresholds
PRODUCT INCLUDES
Soft carrying pouch, adapter - US wall plug to USB, 6 ft USB cable, (2) 1.5 V AA batteries, printed quick start guide, and a USB drive with DataView® software and user manual.

ACCESSORIES/REPLACEMENTS

Catalog #2138.61 Wall Mount Holster (Gray)

Catalog #2153.78 Adapter - US Wall Plug to USB

Catalog #2138.63 Calibration Kit Catalog #2138.66 6 ft USB cable

Catalog #2117.73 Replacement Carrying Pouch

DESCRIPTION Air Quality Logger Model 1510 (White)

Vol. 23 Rev.00 02/2023

Technical Assistance (800) 343-1391
© Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved.

www.aemc.com 57

ENVIRONMENTAL TESTERS
SOUND LEVEL METER

MODEL CA832
Designed to assess sound ambiences or nuisances in accordance with international safety and quality standards

SPECIFICATIONS

MODEL

CA832

MEASUREMENTS Measurement Range
Measurement Rate

(37 to 80) dB (50 to 100) dB (80 to 130) dB
2.5 times per s

Dynamic Range

50 db

Frequency Range

(31.5 to 8000) Hz

Accuracy

± 1.5 dB (ref. 94 dB @ 1 kHz)

Resolution

0.1 dB

Precision

± 2.0 dB

Display Sensor Type
Applicable Standard Auxiliary Output
Frequency Weighting

2000-count
0.5 in (13 mm) electric (pre-polarized) condenser microphone True RMS measurement with independent frequency weighting
IEC 651 Type 2 / ANSI S 1.4 Type 2 / JIS C 1502
DC output: 10 mV/dB ­ 50  AC output: 1.0 Vrms ­ 600 
Curves A and C

Time Weighting

S (slow) - 550 ms and F (fast) - 55 ms

GENERAL

Display

3½ digit liquid crystal display (LCD), 2000-count

Operating Temperature

(32 to 122) °F (0 to 50) °C, 80 % RH without condensation

Storage Temperature

(-4 to 140) °F (-20 to 60) °C, (0 to 80) % RH without battery

Power Supply

(1) 9 V Alkaline battery (included)

Low Battery Indication

is displayed when battery voltage is low

Dimensions

(9.33 x 2.38 x 1.5) in (237 x 60 x 38) mm

Weight

8.11 oz (230 g) including battery

Consult factory for NIST Calibration prices

PRODUCT INCLUDES
Shockproof holster, protective foam microphone cap, screwdriver, male jack connector, assembly screw for camera type tripod, 9 V battery and user manual.

Tripod mounting screw allows for mounting on a standard tripod stand. (Tripod not included)

CATALOG NO. 2121.23

DESCRIPTION Sound Level Meter Model CA832

IP 44
FEATURES
· Easy one-hand operation · Measures sound according to the sensitivity
of the human ear · Max function · Three measurement ranges from (37 to 130) dB · Accuracy ± 1.5 dB (ref. 94 dB @ 1 kHz) · Two time weighting curves:
S (slow) - 550 ms and F (fast) ­ 55 ms · Two frequency weighting curves: A and C · Auxiliary output for recording · Tripod mountable · 2000-count backlit LCD · Lightweight and compact · Includes rugged, shockproof, protective
and dirt resistant gray cover
APPLICATIONS
· Factories · Schools and libraries · Airports · Office environments and studios · Auditoriums · Hospitals · Art Galleries

58 www.aemc.com

Technical Assistance (800) 343-1391
© Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved.

Vol. 23 Rev.00 02/2023

ENVIRONMENTAL TESTERS
THERMO-HYGROMETER

MODEL 1246

Measure humidity and temperature in all conditions

SPECIFICATIONS

MODEL

1246

RELATIVE HUMIDITY

Measurement Range

(3.0 to 98.0) % RH

Accuracy

(10 to 90) % RH: ± (2 % RH ± 1 ct), outside that range: ± (4 % RH ± 1 ct)

Resolution

0.1 % RH

Response Time (66 %)

60 s

TEMPERATURE

Type of Sensor

Temperature sensor with semiconductor

Measurement Range

(-10.0 to + 60.0) °C; (14.0 to + 140.0) °F

Resolution

Display in °C: 0.1 °C; Display in °F: 0.1 °F

Accuracy (°C)

(10 to 40) °C: ± (0.5 °C ± 1 ct) Outside that range: ± (0.032 x (T-25) ± 1 ct) / T= temperature in °C

Response Time (66 %)

30 s

DEW POINT

Measurement Range

(-10.0 to + 60.0) °Ctd; (14.0 to + 140.0) °Ftd

Resolution

Display in °C: 0.1 °C; Display in °F: 0.1 °F

FUNCTIONS

Recording

Manual Start/Stop Short press for MEM: spot recording Long press for REC: recording at the user selectable rate
Programmed recording rates from 1 min to 2 h Start date and end date can be customized with the PC software

Alarms

Alarm thresholds settable in the software Recording can be triggered on an alarm threshold

Data storage

More than 1 million measurements

Min-Max

Real-time display of Min and Max readings available at the press of a button

Hold

Freezes the measurement value on the display

Units

°C or °F / % RH

Automatic power-off

User selectable choice of 3 min, 5 min, 10 min, or OFF through DataView® software

POWER SUPPLY

Type

(3) 1.5 V AA / LR6 alkaline batteries. Connection to line power using supplied micro-USB cable. Wall adapter sold separately

Battery Life

1,000 h (portable mode) 3 y of recording (15-minute measurement interval)

GENERAL

Interfaces Mounting

2 Communication modes: Bluetooth wireless link and USB
Case equipped with a magnet for mounting to a metal surface and a tear drop for wall mounting. Compatible with the Multifix accessory (cat. #5000.44)

Dimensions / Weight (7.36 x 2.84 x 1.28) in (187 x 72 x 32) mm / 14.1 oz (400 g) with batteries

Operating Range

Temperature: (14 to 140) °F (-10 to +60) °C / Humidity: (10 to 90) % RH

DataView® software Display as a graph or table of values; Data export in graph/MS Excel table;

Functions

Real-time mode; Automatic standard or custom report generation

SAFETY/WARRANTY

Safety Rating

IEC61010-1 / IEC 61326-1

Ingress Protection

IP54

Warranty

2 y

Consult factory for NIST Calibration prices

CATALOG NO.

DESCRIPTION

2121.73

Thermo-Hygrometer Data Logger Model 1246

IP 54
FEATURES
· Measures temperature, humidity and dew point
· Dual line display toggles between any two of the measurements
· User selectable temperature units (°F or °C) · Built in sensor with removable protective cap · Min, and Max measurements stored · Hold function freezes the display · Spot or continuous recording up to
1 million measurements · Blue luminescent backlit display · Programmable alarms for temperature and
humidity through included software · USB and Bluetooth communication · Magnetic mount · Battery or USB powered · DataView® graphing and analysis software

PRODUCT INCLUDES
Soft carrying case, 6 ft USB cable (Type A to Type B USB), (3) 1.5 V AA alkaline batteries, printed quick start guide, and a USB drive with DataView® software and user manual.

ACCESSORIES

Catalog #2118.09 General Purpose Carrying Case
Catalog #2118.65 Soft Carrying Case
Catalog #2122.31 Shockproof Housing

Catalog #2138.66 6 ft USB cable
Catalog #2153.78 Adapter - US Wall Plug to USB
Catalog #5000.44 MultiFix Universal Mounting System

Vol. 23 Rev.00 02/2023

Technical Assistance (800) 343-1391
© Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved.

www.aemc.com 59

ENVIRONMENTAL TESTERS
THERMO-HYGROMETER

MODEL CA846
Provides excellent response time to changes in temperature, good repeatability and accurate readings

SPECIFICATIONS

MODEL

CA846

MEASUREMENTS -- TEMPERATURE

Measurement Range

(-4 to 140) °F (-20 to 60) °C

Display Resolution

0.1 °F (0.1 °C)

Sensor

NTC Temperature Sensor

Accuracy

(-4 to 32) °F: ± 2 °F (-20 °C to 0 °C: ± 1 °C) (32 to 140) °F: ± 1 °F (0 °C to 60 °C: ± 0.5 °C)

MEASUREMENTS -- RELATIVE HUMIDITY

Measurement Range

(0 to 100) % RH

Display Resolution

0.1 % RH

Sensor

Capacitive Humidity Sensor

Accuracy

± 5.0 %, 25 °C, (10 to 90) % RH ± 10.0 %, 25 °C, (0 to 10) % RH, (90 to 100) % RH

GENERAL

Display

3½ digit liquid crystal display (LCD), 2000-count

Operating Temperature

(32 to 122) °F (0 to 50) °C, 80 % RH

Storage Temperature

(-4 to 140) °F (-20 to 60) °C, (0 to 80) % RH without battery

Polarity

Automatic

Power Supply

(1) 9 V Alkaline battery (included)

Low Battery Indication

is displayed when battery voltage is low

Dimensions

(6.81 x 2.38 x 1.5) in (173 x 60 x 38) mm

Weight

Approx. 7 oz (198 g) including battery

FEATURES
· Easy one-hand operation · Measures temperature in °F and °C · Accurate NTC sensor · Quick response RH sensor · MAX and HOLD functions · 2000-count backlit LCD · Lightweight and compact · Removable protective sensor cover · Includes rugged, shockproof, protective
and dirt resistant gray cover

PRODUCT INCLUDES
Shockproof holster, 9 V battery and user manual.
APPLICATIONS
· Greenhouses · HVAC installation and maintenance · Office environments · Labs · Environmental studies · Weather monitoring · Food distribution and storage · Blood banks

CATALOG NO. 2121.24

DESCRIPTION Thermo-Hygrometer Model CA846 (NTC)

60 www.aemc.com

Technical Assistance (800) 343-1391
© Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved.

Vol. 23 Rev.00 02/2023

ENVIRONMENTAL TESTERS
TEMPERATURE
MODEL 1822 Versatility & high performance temperature measurement

1822

IP 50
with USB connector closed

PRODUCT INCLUDES
Soft carrying case, 6 ft USB cable (Type A to Type B USB), (2) K Thermocouple flexible sensors, (3) 1.5 V AA alkaline batteries, printed quick start guide, and a USB drive with DataView® software and user manual.

ACCESSORIES/REPLACEMENTS

Catalog #2117.73 Carrying Pouch
Catalog #2138.66 6 ft USB cable
Catalog #5000.44 MultiFlex Universal Mounting System

Catalog #2153.78 Adapter ­ US Wall Plug to USB
Catalog #2122.31 Shockproof Housing

FEATURES
· Selectable Thermocouple type, J, K, T, N, E, R, S · Single and dual channel · Dual line display · User selectable temperature units, °F, °C · Min and Max measurements stored · HOLD function freezes the display · Spot or continuous recording up to 1 million measurements · Blue luminescent backlit display · Programmable store on alarm function · Magnetic mount · Programmable alarms through software · DataView® graphing and analysis software included · Battery or USB powered · Free app for AndroidTM from the Google® Play Store

CATALOG NO. 2121.75

DESCRIPTION Thermocouple Thermometer Data Logger Model 1822

Vol. 23 Rev.00 02/2023

Technical Assistance (800) 343-1391
© Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved.

www.aemc.com 61

ENVIRONMENTAL TESTERS
TEMPERATURE DATA LOGGER MODEL 1822

1822 Thermocouple Thermometer

MEASUREMENTS
Measurement Range
Resolution Accuracy (°C)
J, K, T, N, E: R, S:
FUNCTIONS
Recording
Alarms Data Storage

J, K, T, N, E, R, S: 2 Channel
J: (210 to + 1,200) °C / (-346 to + 2,192) °F K: (200 to + 1,372) °C / (-328 to + 2,501) °F
T: (250 to + 400) °C / (-418 to + 752) °F N: (200 to + 1,300) °C / (-328 to + 2,372) °F E: (150 to + 950) °C / (-238 to + 1,742) °F
R,S: (0 to + 1,767) °C / (32 to + 3,212) °F
Display in °C: ø < 1,000 °C : 0.1 °C and ø  1,000 °C : 1 °C Display in °F: ø < 1,000 °F : 0.1 °F and ø  1,000 °F : 1 °F
ø  - 100 °C ± (0.2 % Reading + 0.6 °C) - 100 °C < ø  + 100 °C ± (0.15 % R + 0.6 °C)
+ 100 °C < ø ± (0.1 % R + 0.6 °C) ø  + 100 °C ± (0.15 % R + 1.0 °C) + 100 °C < ø ± (0.1 % R + 1.0 °C)
Manual Start/Stop Short press on MEM: spot recording Long press on REC: recording at the user selectable rate Programmed recording rates from 1 min to 2 h Start date and end date can be customized with the PC software Alarm thresholds set using the software. Visual alert on the product in the event of an overrun. Recording can be triggered on alarm thresholds.
More than 1 million measurements

Min-Max

Real-time display of Min and Max readings available at the press of a button.

Hold

Freezes the measurement value on the display.

Differential Measurement

Yes

Units

°C or °F

Backlighting

Blue luminescent

Automatic Power Off MECHANICAL Interfaces

User selectable choice of 3, 5 or 10 min, or off through DataView® software. 2 communication modes: Bluetooth and USB

Mounting

Case equipped with a magnet, a wall mount system and a slot for suspension of the product. Compatible with the MultiFix accessory (Cat. #5000.44). Shockproof housing available as an accessory (Cat. #2122.31).

Connections

Compensated miniature female connectors

Dimensions/Weight

(5.9 x 2.84 x 1.28) in (150 x 72 x 33) mm / 9.2 oz (260 g) with batteries

Operating Range POWER SOURCE
Type
Battery Life
SAFETY Safety Rating Ingress Protection GENERAL DataView® Software Functions

Temperature from (14 to 140) °F (-10 to +60) °C / Humidity from (10 to 90) % RH
(3) 1.5 V AA / LR6 alkaline batteries Connection to line power using supplied micro-USB cable. Wall adapter sold separately
Model 1821 & 1822: 1,000 h (portable mode) Model 1823 : 800 h (portable mode) 3 y for recording (15-minute measurement interval)
IEC61010-1 / IEC 61326-1 IP50 with the USB connector closed, per IEC 60 529
Real-time mode; Automatic report generation in Microsoft Word format Graph or value-table presentation; Data export in graph or Microsoft Excel table format

Warranty

2 y

62 www.aemc.com

Technical Assistance (800) 343-1391
© Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved.

Vol. 23 Rev.00 02/2023

ENVIRONMENTAL TESTERS
LIGHTMETER

MODEL 1110
Features optical sensors that are designed to match the response of the human eye

SPECIFICATIONS

MODEL

1110

Measurement Range

(0.01 to 200,000) lx

(0.01 to 18,580) fc

Accuracy

± 3 % of R on incandescent sources ± 6 % of R on LEDs (3,000 to 6,000) K
± 9 % of R on fluorescent sources

Accuracy with Compensation

LED mode: ± 4 % of R (at 4,000 K) Flou mode: ± 4 % of R (type F11, 4,000 K)

Display Resolution

0.1 lx (0.1 to 999.9) lx 1 lx (1,000 to 9,999) lx 10 lx (10,000 lx to 99.99 klx)
100 lx beyond

0.01 fc (0.01 to 99.99) fc 0.1 fc (100.0 to 999.9) fc 1 fc (1,000 to 9,999) fc
10 fc beyond

Recording

Manual start/stop on the product Short press for MEM: spot recording Long press for REC at the defined default rate Programed recording: start date, recording interval, and end date defined using DataView® software

Other Functions

MIN-AVG-MAX-HOLD

Sampling Rate

Programmable from 1, 2, 5, 10, 20, or 30 s, 2, 5, 10, 15 or 30 min, and 1 hr

MAP mode

The MAP mode can be used to map the lighting on the surface of a room. In this case the measurements are saved in the same file.

Operating Temperature

(14 to 140) °F (-10 to 60) °C

Storage Temperature

(-4 to 140) °F (-20 to 60) °C

Relative Humidity

Up to 90 % RH

GENERAL

Memory

1,000,000 measurements on each channel (4 MB). Recorded data is stored in non-volatile memory and will be retained even if battery is low or removed.

Communication

USB 2.0 and Bluetooth

Power Supply

(3) 1.5 V AA (LR6) alkaline batteries or USB port (micro-USB adaptor offered as an accessory)

Battery Life

500 h, 3 yrs with 15 min intervals

Dimensions

Case: (5.9 x 2.84 x 1.28) in (150 x 72 x 33) mm Sensor: (2.64 x 2.52 x 1.38) in (67 x 64 x 35) mm

Weight (with battery)

12.2 oz (34 g) with batteries

Case

Polycarbonate

SAFETY

EMC

EN 61326-1

Safety Rating

IEC 61010-1

Ingress Protection

IP50 with USB connector closed and protective cap on sensor

Warranty

2 y

Consult factory for NIST Calibration prices

CATALOG NO. 2121.71

DESCRIPTION Lightmeter Data Logger Model 1110

IP 50

FEATURES
· User selectable light source, natural, LED or fluorescent · Spectral error compensation for LED and fluorescent
lighting · Removable light sensor with expandable cable up to
48 inches · Map mode profiles the illuminance map of the area
or room by storing multiple measurements · Min, Max, and Average measurements stored · Free app for AndroidTM from the Google® Play Store · Spot or continuous recording of up to 1,000,000
measurements stored in 8 MB flash memory · Blue luminescent backlit display · User selectable foot-candle (fc) or lux (lx) units · USB and Bluetooth communication · Magnetic mount · Battery or USB powered · DataView® graphing and analysis software included

Measure and record multiple measurements to create an illuminance map of the room or area of interest

PRODUCT INCLUDES
Soft carrying pouch, 6 ft USB cable, (3) 1.5 V AA batteries, a printed quick start guide, USB drive with DataView® software and user manual.

ACCESSORIES/ REPLACEMENTS
Catalog #2118.65 Soft Carrying Case
Catalog #2138.66 6 ft USB cable
Catalog #2118.09 General Purpose Carrying Case
Catalog #2122.31 Shockproof Housing
Catalog #2153.78 Adapter - US Wall Plug to USB
Catalog #5000.44 MultiFix Universal Mounting System

Vol. 23 Rev.00 02/2023

Technical Assistance (800) 343-1391
© Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved.

www.aemc.com 63

AEMC® Instruments is a global leader in Power/Energy Quality Analyzers, Meters and Loggers, Current Probes, Ground Resistance Testers and Insulation Testers. We are the brand you can trust!

GROUND RESISTANCE TESTERS

DATA ANALYSIS AND REPORTING SOFTWARE

SEE PAGE 133 FOR MORE INFO ON DATAVIEW® SOFTWARE

CONFIGURE GROUND RESISTANCE TESTERS
MODELS 6417, 6471 & 6472
Run tests and analyze real-time data from your PC / Configure all test functions and parameters from your PC / Customize views, templates and reports / Display Fall-of-Potential plots, tabular listing of test results and more / Print reports of all test results

SEE WEBSITE FOR PRICING AND AVAILABILITY: WWW.AEMC.COM

GROUND RESISTANCE TESTERS
MULTI-FUNCTION
MODELS 6422 & 6424 To keep your installation safe, measure the resistance of its connection to earth

SPECIFICATIONS
MODELS ELECTRICAL Voltage Measurement Range Resolution Accuracy Current Range Ground Resistance (2P Mode) Measurement Range Resolution Accuracy Ground Resistance (3P Mode)

6422

IP 65
6424

­

(0.1 to 600) VAC/DC

­

0.1 V

­

± (1 % R + 1 ct)

­

(0.5 to 60.00) AAC (requires optional MN72 probe)

(0.05 to 99.99) , (80.0 to 999.9) , (0.80 to 9.999) k, (8.00 to 50.00) k 0.01 , 0.1 , 1 , 10 
± (2 % R + 10 ct), ± (2 % R + 2 ct), ± (2 % R + 1 ct), ± (2 % R + 1 ct)

Measurement Range (0.50 to 99.99)  (80.0 to 999.9)  (0.800 to 2.000) k (0.50 to 99.99)  (80.0 to 999.9)  (0.800 to 9.999) k (8.00 to 50.00) k

Resolution

0.01 

0.1 

1 

0.01 

0.1 

1 

10 

Accuracy

± (1 % R + 10 ct) ± (1 % R + 2 ct) ± (1 % R + 1 ct) ± (1 % R + 10 ct) ± (1 % R + 2 ct)

± (1 % R + 1 ct)

Measurement Frequency

(128 or 256) Hz (automatically selected)

No-load Voltage Maximum Test Current

± 10 V peak 20 mA

Measurement Mode Data Storage

One shot or continuous

­

Stores the (52, 62 and 72) % 3P resistance measurements

Calculation GENERAL

­

Calculates average and % deviation of the three saved readings

Display Measurement Mode

2P (), 3P ()

Backlit LCD

V, I, 2P (), 3P ()

Power Supply Battery Life

(6) AA alkaline batteries > 2,000 x 3P earth measurements at 100 

(6) NiMH rechargeable batteries, charging time approx. 6 h > 1,500 x 3P earth measurements at 100 

Dimensions SAFETY

(8.78 x 4.96 x 2.75) in (223 x 126 x 70) mm

Safety Rating

EMC: IEC 61326-1; IEC 61010-2-030 / 600 V CAT IV

Consult factory for NIST Calibration prices

CATALOG NO. 2135.55 2135.56 2135.57 2135.58 2135.59

DESCRIPTION Ground Resistance Tester Model 6422 (Digital, 3-Point) Ground Resistance Tester Model 6422 Kit-150 ft (Digital, 3-Point) Ground Resistance Tester Model 6424 (Digital, 3-Point) Ground Resistance Tester Model 6424 Kit-150 ft (Digital, 3-Point) Ground Resistance Tester Model 6424 Kit-300 ft (Digital, 3-Point)

66 www.aemc.com

Technical Assistance (800) 343-1391
© Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved.

Vol. 23 Rev.00 02/2023

GROUND RESISTANCE TESTERS
MULTI-FUNCTION

MODELS 6422 & 6424

FEATURES

· Simple, one button operation - eliminates errors in testing

· Test button turns green when measurement is stable

· 2 P resistance measurement up to 50 k

· 3 P ground resistance measurement up to 2 k (Model 6422) up to 50 k (Model 6424) for highly resistive terrain

· Large back lit digital display ­ easier to read in all lighting conditions

· Automatic hold function - retains last measurement after the reading stabilizes ensuring the measurement is valid

· Automatic test frequency selection between 128 Hz and 256 Hz, providing stable results in adverse environments

· Powers up in 2 pole mode ­ automatically checks the injector lead connection when connected to the H auxiliary rod

· Convenient storage of the three measurements along with the average and % deviation - easily determines proper test results

· Built in test lead compensation capability ­ improves the accuracy of low resistance measurements

· CAT IV 600 V rated for a high level of operator safety

· Checks AC/DC voltage (Model 6424)

· Stores (52, 62 and 72) % measurements ­ eliminates errors in determining the ground resistance (Model 6424)

· Leakage current measurement from 0.5 mA to 60 A (Model 6424)

· Battery recharging via AC adapter, USB or vehicle DC port (Model 6424)

· Color coded leads and terminals provide fast, error-free connection

· Detects the presence of hazardous voltage and prohibits measurement

· Direct access to all functions, even when wearing work gloves

· Rugged water resistance case, for all terrain use

· Built-in display stand to prop up instrument for seeing the display better when placed on the ground

ACCESSORIES/REPLACEMENTS

Catalog #2135.39 Ground Rod ­ Set of (2) 14.5 in T-shaped Auxiliary Rods

Catalog #2153.06 MN72 AC Current Probe (6424 only)

CATALOG #5000.92 Calibration Checker

CATALOG #5000.92

FUNCTIONAL DISPLAYS

2 P mode used for continuity and bonding checks ­ is active when
the instrument is turned on
Model 6424

3 P mode used for measuring the grounding system. The resistance of the injector electrode and the test
voltage are also displayed

Live voltage is displayed when the V/A function is selected and test leads
are connected to AC or DC voltage (Model 6424)

Leakage current is displayed when the optional MN72 probe is connected
and the V/A function is selected (Model 6424)

FRONT PANEL - 6424

PRODUCT INCLUDES
Models 6422 and 6424: (2) 150 ft color-coded leads on spools (red/blue), (1) 30 ft lead (green), (2) T-shaped auxiliary ground electrodes, set of (2) 5 ft colorcoded (red/blue) leads, (1) 100 ft tape measure, (6) AA rechargeable NiMH batteries, carrying bag and user manual Model 6424 also includes: USB to wall charger, 5 V, 2 A, USB charger cable

CATALOG #2153.06

KITS AVAILABLE SHOWN: CATALOG #2135.35

Vol. 23 Rev.00 02/2023

Technical Assistance (800) 343-1391
© Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved.

www.aemc.com 67

GROUND RESISTANCE TESTERS
DIGITAL TESTERS

MODELS 4620 & 4630
Both models will perform over 2000 measurements for the 15 second tests between recharging or battery replacement

SPECIFICATIONS
MODELS ELECTRICAL Range Measurement Range Resolution Open Voltage Measurement Frequency Test Current Accuracy

4620

4630

20 

200 

2000 

(0.00 to 19.99)  (20.0 to 199.9)  (200 to 1999) 

10 m

100 m

1 

 42 V peak

128 Hz square wave

10 mA

1 mA

0.1 mA

± 2 % of Reading ± 1 ct ± 5 % of Reading ± 3 cts

Aux Electrode Influence

Max Res. - Current Circuit

3 k

Max Res. - Voltage Circuit

30 k 50 k

50 k

Response Time Withstanding Voltage Power Supply
Battery Life Fuse Protection

Approximately four to eight seconds for a stabilized measurement

250 VAC or 100 VDC

(8) C cell batteries

(120/230) V, (50/60) Hz

(included);

Rechargeable 9.6 V, 3.5 A·h

Alkaline recommended NiMH battery pack (included)

> 2000 15-second measurements; LO BAT indication on LCD

0.1 A, > 250 V , (0.25 x 1.25) in; 30 kA Interrupt Capacity

Consult factory for NIST Calibration prices

ACCESSORIES/REPLACEMENTS

Catalog #2130.60 Tape Measure (100 ft)
Catalog #2135.35* Test Kit for 3-Point Testing ­ 150 ft Catalog #2135.36* Test Kit for 4-Point Testing ­ 300 ft
Catalog #2135.37* Test Kit for 4-Point Testing ­ 500 ft

Catalog #2135.38 Ground Test Kit for 3-Point Testing (Supplemental for 4-Point testing ­ includes (2) 100 ft color-coded leads, (1) 30 ft lead (green), (2) 14.5 in T-shaped auxiliary ground electrodes and soft carrying bag)
Catalog #2130.59 Calibration Checker 25  for Models 3640, 4500, 4610, 4620 and 4630

Catalog #5000.14 AC Power cord (4630)

KIT SHOWN
4630 KIT (500 ft)

4620

4630

IP

IP

65

53

cover closed cover open

FEATURES
· Ground Integrity Measurement · Measures soil resistivity (4-Point) · Measures ground resistance (2- and 3-Point)
Fall-of-Potential method · Step voltage tests and touch potential measurements · Auto-Ranging: automatically selects the optimum
resistance range and test current · Designed to reject high levels of noise and interference · Extremely simple to operate: connect/press/hold/read · LED on faceplate informs operator of high input
noise, high auxiliary rod resistance and faulty connections · Large easy-to-read backlit display · Battery powered (Model 4620) · AC powered with rechargeable NiMH battery pack (Model 4630) · Rugged dustproof and watertight field case · Color-coded terminals

PRODUCT INCLUDES
(8) C-cell batteries (4620) or rechargeable 9.6 V NiMH battery pack (4630), AC power cord (4630), and user manual.

*Refer to page 75 for Test Kit descriptions
CATALOG NO. 2130.43 2130.44 2135.19 2135.20 2135.21 2135.22 2135.23 2135.24

DESCRIPTION
Ground Resistance Tester Model 4620 (Digital, 4-Point, Battery Powered) Ground Resistance Tester Model 4630 (Digital, 4-Point, Rechargeable Battery) Ground Resistance Tester Model 4620 Kit ­ 150 ft (Model 4620 and Catalog #2135.35) Ground Resistance Tester Model 4620 Kit ­ 300 ft (Model 4620 and Catalog #2135.36) Ground Resistance Tester Model 4620 Kit ­ 500 ft (Model 4620 and Catalog #2135.37) Ground Resistance Tester Model 4630 Kit ­ 150 ft (Model 4630 and Catalog #2135.35) Ground Resistance Tester Model 4630 Kit ­ 300 ft (Model 4630 and Catalog #2135.36) Ground Resistance Tester Model 4630 Kit ­ 500 ft (Model 4630 and Catalog #2135.37)

68 www.aemc.com

Technical Assistance (800) 343-1391
© Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved.

Vol. 23 Rev.00 02/2023

GROUND RESISTANCE TESTERS
CLAMP-ON

MODELS 6416 & 6417
Provides high safety level with new ground voltage indication feature

SPECIFICATIONS

MODELS

6416 & 6417

ELECTRICAL

Ground Resistance

Measurement Range
(0.010 to 0.099) 
(0.10 to 0.99) 

Resolution
0.001  0.01 

Accuracy (% of Reading)
± 1.5 % ± 0.01 
± 1.5 % ± 0.02 

Auto-Ranging (0.01 to 1499) 

(1.0 to 49.9)  (50.0 to 99.5)  (100 to 199) 

0.1  0.5  1 

± 1.5 % ± 0.1  ± 2 % ± 0.5  ± 3 % ± 1 

(200 to 395) 

5 

± 5 % ± 5 

(400 to 590) 

10 

± 10 % ± 10 

(600 to 1150) 

50 

20 % approx

(1200 to 1500) 

50 

25 % approx

Current Measurement

(0.200 to 0.999) mA
(1.000 to 2.990) mA (3.00 to 9.99) mA

1 µA 10 µA

± 2 % ± 50 µA

Auto-Ranging 1 mA to 40 A

(10.00 to 29.90) mA (30.0 to 99.9) mA

100 µA

± 2 % ± 100 µA

(100.0 to 299.0) mA (0.300 to 0.990) A

1 mA

± 2 % ± 1 mA

(1.000 to 2.990) A (3.00 to 39.99) A

10 mA

± 2 % ± 10 mA

Selectable Measurement Frequency

(50, 60, 128 or 2083) Hz

Current Measurement Frequency

(47 to 800) Hz

Inductance Measurement

(10 to 100) µH; (100 to 500) µH

Current Overload

OL displayed above 39.99 Arms

Communication Power Supply SAFETY

Bluetooth connection (Model 6417 only)
(4) 1.5 V LR6 (AA) alkaline batteries or (4) NiMH batteries; Battery life: 12 h, or 1440, 30 - s measurements approx.

Safety Rating

EN 61010-1, 600 V CAT IV

Consult factory for NIST Calibration prices

PRODUCT INCLUDES
6416 & 6417 Hard carrying case, wrist strap calibration loop, (4) 1.5 V AA batteries and user manual.
6417 Also includes Bluetooth USB adapter, printed quick start guide, a USB drive with DataView® software, ground tester workbook and user manual.

6416

6417

** * IP 40

FEATURES

*6417 only

· Ground Integrity Measurement

· Ground voltage indication (warns of possible unsafe conditions)

· Large multi-function bright yellow OLED (organic LED display)

· Selectable test frequency (improves accuracy in inductive environments)

· Clamping diameter of 1.37 in (35 mm) with large jaw design

· Storage of measurements ( and/or A, with time-stamping)

· Model 6416: up to 300 measurements stored

· Model 6417: up to 2000 measurements stored

· View stored measurements on the OLED display or via Bluetooth (Class 2 - communicates up to 30 ft) to a PC or the AndroidTM based mobile application (Model 6417)

· Auto Power OFF function

· Alarm function with adjustable set point and buzzer for quick field checks for volts, amps and ohms

· Rugged Lexan® head and body construction resists breakage

· Alarm settings and stored memory information saved during shutdown

· Includes DataView® software for data retrieval, real-time display, analysis, report generation and system configuration (Model 6417)

· Noise icon and buzzer alert user to presence of dangerous voltage and current levels

CATALOG NO.
2141.01 2141.02

DESCRIPTION
Ground Resistance Tester Model 6416 (Clamp-On, Alarm, Memory) Ground Resistance Tester Model 6417 (Clamp-On, Bluetooth, Alarm, Memory, DataView® Software)

Vol. 23 Rev.00 02/2023

Technical Assistance (800) 343-1391
© Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved.

www.aemc.com 69

GROUND RESISTANCE TESTERS
CLAMP-ON

MODEL 6418
Designed for measuring ground impedance on ground rods and bus bars

SPECIFICATIONS

MODEL ELECTRICAL

6418

Measurement Range

Resolution

Accuracy (% of Reading)

(0.010 to 0.099)  0.001  ± 1.5 % ± 0.01 

(0.10 to 0.99)  0.01  ± 1.5 % ± 0.02 

Ground Resistance

(1.0 to 49.9)  (50.0 to 149) 

0.1  ± 1.5 % ± 0.2 

1 

± 2.5 % ± 2 

Auto Ranging

(150 to 245)  (250 to 440) 

5 

± 5 % ± 10 

10 

± 10 % ± 20 

Measurement Frequency
Current Measurement

(450 to 640) 

10 

(650 to 1200) 

50 

2083 Hz
(0.50 to 9.950) mA 50 µA (10.00 to 99.90) mA 100 µA

± 15 % ± 20  ± 20 % Reading
+ 100 
± 2 % + 200 µA ± 2 % + 100 µA

Auto Ranging 1 mA to 20 A

(100.0 to 299.0) mA

1 mA

± 2 % ± 1 mA

(0.300 to 2.990) A 10 mA ± 2 % ± 10 mA

Current Measurement Frequency Current Overload
Power Supply

(3.000 to 20.00) A 100 mA ± 2 % ± 100 mA
(47 to 800) Hz
OL displayed above 19.99 Arms (4) 1.5 V LR6 (AA) alkaline batteries or
(4) NiMH batteries; Battery life: 12 h, or 1440 30 s
Measurements approx.

Consult factory for NIST Calibration prices

PRODUCT INCLUDES
Hard carrying case, 5 « calibration loop, (4) 1.5 V AA batteries, wrist strap and a user manual.

SAFETY

IP

R ATIN G

40

CLAMPING CHARACTERISTICS

30

20

Ø32

40 55

FEATURES
· Ground Integrity Measurement · Large multi-function bright yellow OLED (organic LED display)
(1.89 x 1.55) in (48 x 39) mm · Clamping diameter accommodates both cable and bus bar · Storage of measurements ( and/or A, with time-stamping) · Up to 300 measurements stored · View stored measurements on the OLED display · Auto Power OFF function · Auto Hold · Alarm function with adjustable set point and buzzer for quick
field checks for amps and ohms · Rugged Lexan® head and body construction resists breakage · Alarm settings and stored memory information saved
during shutdown · Noise icon and buzzer alert user to presence of dangerous
current levels · Designed to EN 61010-1, 100 V CAT IV and 150 V CAT III
safety standards · Automatic calibration of the jaw gap at power-up

CATALOG NO. 2141.03

DESCRIPTION Ground Resistance Tester Model 6418 (Clamp-On, Alarm, Memory, Oblong Jaws)

70 www.aemc.com

Technical Assistance (800) 343-1391
© Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved.

Vol. 23 Rev.00 02/2023

GROUND RESISTANCE TESTERS
CLAMP-ON
FUNCTIONAL DISPLAYS
Disturbance indicator (current) in the loop HOLD Function active
Buzzer is displayed when active Measurement date/time display
Advanced Mode selection Indicates when the inductive
component is negligible in Advanced Mode
Main measurement display
Measurement unit display

Data Storage Mode Memory Recall Mode Memory index number display Bluetooth connection indicator
(6417 only)
MEASUREMENT RESULTS

Note: Display shown larger than actual size MEMORY RECALL MODE

Incorrect jaw closing indicator Auto Power OFF active Battery charge indicator
4000-count upper measurement display Upper display measurement unit
Main display measurement unit
Hazardous voltage indicator (not available on 6418) Alarm measurement display unit Alarm threshold display Alarm active indicator
ALARM

Displays the leakage current and loop impedance at the test frequency
LOOP DETECTION

Measurement storage date-time screen GROUND VOLTAGE

Indicates voltage/current alarm threshold along with the direction of impedance
IMPEDANCE OVER RANGE

Detects and displays possible false readings associated with metal loops

Indicates voltage potential at the point of measurement

Indicates that the impedance is greater than 1500 

Vol. 23 Rev.00 02/2023

Technical Assistance (800) 343-1391
© Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved.

www.aemc.com 71

GROUND RESISTANCE TESTERS
MULTI-FUNCTION

MODEL 6471
Test ground resistance without the need of auxiliary rods or with the 3- and 4- Point methods

SPECIFICATIONS

MODEL

6471

ELECTRICAL

2-Clamp Measurement

Range

(0.10 to 500) 

Resolution

(0.01 to 1) 

Measurement Frequency

Auto: 1611 Hz Manual: (128, 1367, 1611, or 1758) Hz

3-Point Measurement

Range (Auto-Ranging)

0.09  to 99.9 k

Resolution

(0.01 to 100) 

Test Voltage

Nominal (16 or 32) Vrms user selectable

Resistance Measurement Frequency

(41 to 513) Hz automatic or user selectable

Test Current

Up to 250 mA

Accuracy

± 2 % of Reading + 1 ct @ 128 Hz

Soil Resistivity 4-Point Measurement

Test Method

Wenner or Schlumberger selectable with automatic calculation in -meters

Range (Auto-Ranging)

(0.01 to 99.9) k; Ã max: 999 km

Resolution

(0.01 to 100) 

Test Voltage

(16 or 32) V user selectable

Frequency

From (41 to 128) Hz selectable

External Voltage Measurement

Range (Auto-Ranging)

(0.1 to 65.0) VAC/DC ­ DC to 440 Hz

Accuracy

± 2 % of Reading + 1 ct

Resistance Measurement (Bond Testing)

Measurement Type

2-Pole (with lead resistance compensation) or 4-Pole (Kelvin sensing) user selectable

Range (Auto-Ranging)

2-Pole (0.12 to 99.99) k; 4-Pole (0.02 to 99.99) k

Accuracy

± 2 % of Reading + 2 cts

Test Voltage

16 VDC (+, - or auto polarity)

Test Current

Up to 250 mA max

Data Storage

Memory Capacity

512 test results (64 kB)

Communication

Optically Isolated USB

Power Supply

9.6 V rechargeable battery pack (included)

Recharging Source

110 V/220 V, (50/60) Hz external charger with 18 VDC, 1.9 A output

Consult factory for NIST Calibration prices

ACCESSORIES

MN82 CURRENT PROBE SR182 CURRENT PROBE REEL CADDY

(2 mA to 10 Arms)

(0.5 mA to 40 Arms)

Catalog #2135.85 Set of (2),

Catalog #2135.71

Catalog #2135.72

for use with ground kit spools

IP 53 cover closed
GROUND RESISTANCE MEASUREMENT USING 2 PROBES For systems with parallel ground connections, Models 6471 and 6472 are capable of accurately measuring a ground resistance using probes only. This method involves placing 2 probes around the ground conductor to be tested and connecting them each to the instrument. One probe injects a known signal (32 V/1367 Hz) while the other probe measures the current circulating in the loop. This method saves considerable time when ground testing because it is no longer necessary to set up auxiliary rods or to disconnect the ground connector.
PRODUCT INCLUDES
CAT. #2135.48 MODEL 6471 (without probes) Meter, carrying bag, 110 V/240 V power adapter with US power cord, optical USB cable, rechargeable NiMH battery, and a USB drive with DataView® software, ground tester workbook and user manual. CAT. #2135.49 MODEL 6471 (with probes) Meter, carrying bag, set of (2) SR182 current probes, 110 V/240 V power adapter with US power cord, optical USB cable, rechargeable NiMH battery, and a USB drive with DataView® software, ground tester workbook and user manual.
KIT SHOWN 300 FT KIT: CATALOG #2135.50
Meter, carrying bag for kit, (2) 300 ft color-coded (red/blue) leads on spools, (2) 5 ft color-coded (red/blue) leads, (2) 100 ft hand-tied color-coded (green/black) leads, set of (2) SR182 current probes, 110 V/240 V power adapter with US power cord, optical USB cable, (4) T-shaped auxiliary ground electrodes, set of (5) spaded lugs, 100 ft tape measure, rechargeable NiMH battery, and a USB drive with DataView® software, ground tester workbook and user manual.
2 probes required to perform stakeless testing

72 www.aemc.com

Technical Assistance (800) 343-1391
© Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved.

Vol. 23 Rev.00 02/2023

GROUND RESISTANCE TESTERS
MULTI-FUNCTION

MODEL 6472
Use under difficult conditions such as the presence of high stray currents that normally affect accuracy

SPECIFICATIONS

MODEL

6472

ELECTRICAL

2-Clamp Measurement

Range

(0.1 to 500) 

Resolution

(0.01 to 1) 

Measurement Frequency

Auto: 1611 Hz Manual: (128, 1367, 1611, or 1758) Hz

3-Point Measurement

Range (Auto-Ranging)

0.09  to 99.9 k

Resolution

(0.01 to 100) 

Test Voltage

Nominal (10, 16, 32 or 60) Vrms user selectable

Resistance Measurement Frequency

(41 to 5078) Hz automatic or user selectable

Test Current

Up to 250 mA

Accuracy

± 2 % of Reading + 1 ct @ 128 Hz

Soil Resistivity 4-Point Measurement

Test Method

Wenner or Schlumberger selectable with automatic calculation of test results in -meters

Range (Auto-Ranging)

(0.01 to 99.9) k; Ã max: 999 km

Resolution

(0.01 to 100) 

Test Voltage

(16 or 32) V user selectable

Frequency

From (41 to 128) Hz selectable

External Voltage Measurement

Range (Auto-Ranging)

(0.1 to 65.0) VAC/DC ­ DC to 440 Hz

Accuracy

± 2 % of Reading + 1 ct

Resistance Measurement (Bond Testing)

Measurement Type Range (Auto-Ranging)

2-Pole (with lead resistance compensation) or 4-Pole (Kelvin sensing) user selectable
2-Pole 0.12  to 99.99 k; 4-Pole 0.02  to 99.99 k

Accuracy

± 2 % of Reading + 2 cts

Test Voltage

16 VDC (+, - or auto polarity)

Test Current

Up to 250 mA max

Data Storage

Memory Capacity

512 test results (64 kB)

Communication

Optically Isolated USB

Power Supply

9.6 V rechargeable battery pack (included)

Recharging Source

110 V/220 V, (50/60) Hz external charger with 18 VDC, 1.9 A output

Consult factory for NIST Calibration prices

IP 53 cover closed
The Model 6472 provides an automated way to measure the value of the earth/ground using the Fall-of-Potential method and storing measurements.
PRODUCT INCLUDES
Carrying bag, (110/240) V power adapter with US power cord, optical USB cable, rechargeable NiMH battery, and a USB drive with DataView® software, ground tester workbook and user manual.
TEST KITS
6472 METER 300 ft Kit: Catalog #2135.53 500 ft Kit: Catalog #2135.54 (shown) Refer to page 75 for Model 6472 Kit descriptions Catalog #2135.35, #2135.36 and #2135.37
2 probes required to perform stakeless testing

ACCESSORIES
MN82 CURRENT PROBE (2 mA to 10 Arms) Catalog #2135.71

SR182 CURRENT PROBE (0.5 mA to 40 Arms) Catalog #2135.72

REEL CADDY Catalog #2135.85 Set of (2), for use with ground kit spools

Vol. 23 Rev.00 02/2023

Technical Assistance (800) 343-1391
© Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved.

www.aemc.com 73

GROUND RESISTANCE TESTERS
MULTI-FUNCTION

LARGE FUNCTIONAL DISPLAYS

FEATURES
· Ground Integrity Measurement
· Ground Resistance testing using the 2-clamp method (no auxiliary rods needed)
· 2- and 4-Point Bond Resistance/Continuity measurement (DC Resistance) with automatic polarity reversal
· 3-Point Fall-of-Potential measurement with manual or automatic frequency selection
· 4-Point Soil Resistivity measurement with automatic calculation of Rho (Ã) and user selection of the Wenner or Schlumberger test method
· 3-Point Earth Coupling measurement
· Manual and Automatic frequency scan from (41 to 5078) Hz for optimum test accuracy in electrically noisy environments
· Selectable test voltage of (10, 16, 32 or 60) V up to 250 mA of test current (model dependant)
· Auto Power OFF feature
· Automatic recognition of all electrode connections and their resistance value
· Stores up to 512 complete test results in internal memory
· Display with automatic backlight when entering a function
· Optically isolated USB communication cable included
· Rechargeable NiMH batteries from wall charger or vehicle power (Cat. #2135.43 needed for vehicle power)
· Rugged dustproof and water-resistant field case (IP53 rated in closed position)
· Grounding standards IEC 61557 parts 4 and 5 compliant · Includes DataView® software for set up, data retrieval,
real-time display, analysis, report generation and system configuration
· Can also be used for continuity tests on bonding
2 probes required to perform stakeless testing.

4-POINT BOND TEST
The 4-Point Bond test shows lead connections, bond resistance test results,
test voltage and current SCHLUMBERGER TEST
The Schlumberger test displays test lead connection, soil resistivity (Ã) test results
and electrode spacing DATA STORAGE
Memory Recall displays test results stored at a specific memory location

3-POINT FALL-OF-POTENTIAL TEST
The 3-Point Fall-of-Potential test displays test lead connection, grounding rod
resistance and test electrode resistances TWO CLAMP TEST
The 2-Clamp method displays clamp connection resistance, test current and frequency
WENNER TEST
The Wenner test displays test lead connection, soil resistivity (Ã) test results,
electrode spacing and resistance

CATALOG NO.
2135.48 2135.49 2135.50 2135.51 2135.53 2135.54 2135.60 2135.61

DESCRIPTION
Ground Resistance Tester Model 6471 (Digital, 3-Point, 4-Point, Clamp-on (SR182 probes not included), DataView® Software) Ground Resistance Tester Model 6471 (Digital, 3-Point, 4-Point, Clamp-on, (includes 2-SR182 probes), DataView® Software) Ground Resistance Tester Model 6471 Kit ­ 300 ft (Catalog #2135.49 and Catalog #2135.36) Ground Resistance Tester Model 6472 (Digital, 2-Point, 3-Point, 4-Point, Bond Test, DataView® software) Ground Resistance Tester Model 6472 Kit ­ 300 ft (Catalog #2135.51 and Catalog #2135.36) Ground Resistance Tester Model 6472 Kit ­ 500 ft (Catalog #2135.51 and Catalog #2135.37) Ground Resistance Tester Model 6471 Kit ­ 300 ft w/o Probes (Catalog #2135.48 and Catalog #2135.36) Ground Resistance Tester Model 6471 Kit ­ 500 ft w/o Probes (Catalog #2135.48 and Catalog #2135.37)

74 www.aemc.com

Technical Assistance (800) 343-1391
© Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved.

Vol. 23 Rev.00 02/2023

GROUND RESISTANCE TESTERS
MULTI-FUNCTION

GROUND TESTERS MODELS 6471 & 6472 -- TYPICAL DATAVIEW® FUNCTIONAL DISPLAYS

2-CLAMP METHOD SETUP

FALL-OF-POTENTIAL, STEP-TOUCH POTENTIAL

SELECTIVE 3-POINT TESTING OF MULTIPLE RODS

4-POINT BONDING FOR VERY LOW RESISTANCE

BONDING

SOIL RESISTIVITY

OPTIONAL KITS

150 FT KIT Catalog #2135.35 Test Kit for 3-Point testing includes carrying bag, (2) 150 ft color-coded (red/blue) leads on spools, (2) 5 ft color-coded (red/blue) leads, (1) 30 ft lead (green), (2) 14.5 in T-shaped auxiliary ground electrodes, a set of (5) spaded lugs and (1) 100 ft tape measure.

300 FT KIT Catalog 2135.36 Test Kit for 4-Point testing includes carrying bag, (2) 300 ft colorcoded (red/blue) leads on spools, (2) 5 ft color-coded (red/blue) leads, (2) 100 ft hand-tied color-coded leads (green/black), (4) 14.5 in T-shaped auxiliary ground electrodes, a set of (5) spaded lugs and (1) 100 ft tape measure.

500 FT KIT Catalog #2135.37 Test Kit for 4-Point testing includes carrying bag, (2) 500 ft color-coded (red/blue) leads on spools, (2) 5 ft color-coded (red/blue) leads, (2) 100 ft hand-tied color-coded (green/black) leads, (1) 30 ft lead (green), (4) 14.5 in T-shaped auxiliary ground electrodes, a set of (5) spaded lugs and (1) 100 ft tape measure.

Vol. 23 Rev.00 02/2023

Technical Assistance (800) 343-1391
© Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved.

www.aemc.com 75

GROUND RESISTANCE TESTERS
MULTI-FUNCTION

GROUNDFLEX® FIELD KIT
Test active tower grounds safely without de-energizing or disconnecting any cables

Unique in the industry!

SPECIFICATIONS
MODELS

ELECTRICAL

3-POINT METHOD

Range (Auto-Ranging)

0.09  to 99.9 k

4-POINT & SELECTIVE METHODS
0.011  to 99.99 k

Resolution

(0.01 to 100)  (0.001 to 10) 

IP 53

cover closed

6472 & 6474

GROUND MEASUREMENT WITH 2 CLAMPS

SOIL RESISTIVITY

GROUND POTENTIAL MEASUREMENT

(0.1 to 500) 

0.01  to 99.9 k

0.01 mV to 65.00 V

(0.01 to 1)  (0.01 to 100)  (0.01 to 10) mV

DC RESISTANCE MEASUREMENT
0.02  to 99.99 k
2 wires: (0.01 to 100) 
4 wires: (0.001 to 10) 

MEASUREMENTS WITH 6474 0.067  to 99.99 k
(0.001 to 10) 

Accuracy

± (2 % + 1 count)

± (10 % + 1 count) ± (2 % + 1 count) ± (5 % + 1 count) ± (2 % + 2 counts) ± (5 % + 1 count)

No-Load Voltage
Measurement Frequency
Coupling Measurement

(10, 16, 32 or 60) Vrms (Not applicable w/2-clamp method)

Auto: 1611 Hz

(41 to 5078) Hz

Manual: (128, 1367, 1611,

(41 to 128) Hz

(41 to 5078) Hz

or 1758) Hz

Yes

­

± 16 VDC DC

(10, 16, 32 or 60) Vrms (41 to 5078) Hz

Auxiliary Rod Resistance Measurement Voltage Interference
Soil Resistivity
Type of Measurement
Measurement Current
MECHANICAL Memory/ Communication Dimensions/Weight Safety Safety Rating

0.14  to 99,9 k

3 wires

­ 4 wires

> 200 mAAC

2 clamps
< 26 ARMS (W/SR182) < 5 ARMS (W/MN82)

­

Maximum 60 V peak

Wenner and

Schlumberger

4 wires

3 wires

> 200 mAAC

0.14  to 99,9 k

­ 2 or 4 wires
> 200 mADC

GroundFlex® > 200 mAAC

512-record memory / Optically isolated USB (10.7 x 9.84 x 5.04) in (272 x 250 x 128) mm / Model 6472: 7.05 lb (3.2 kg) / Model 6474: 5.07 lb (2.3 kg)
50 V CAT IV, complies with IEC 61326-1 / IEC 61010 / IEC 61557-1-4-5

Consult factory for NIST Calibration prices

GROUND TESTER 6472 KIT-500 FT Includes meter, rechargeable NiMH batteries, optical USB cable, power adapter (110/240) V with power cord 115 V US, (2) 500 ft color-coded leads on spools (red/blue), (2) 100 ft color-coded leads (hand-tied, green/black), (1) 30 ft lead (green), (4) T-shaped auxiliary ground electrodes, (1) 100 ft AEMC® tape measure, DataView® software, ground tester workbook, user manual on USB drive, (1) carrying bag for meter and (1) carrying bag for kit.
GROUNDFLEX® FIELD KIT 6474
Catalog #2136.03 (Includes Ground Tester 6472 KIT-500 FT) Includes GroundFlex® Adapter Model 6474, Ground Tester Model 6472, (4) GroundFlex® sensors (16 ft/5 m) with (12) color-coded rings, connection lead, (2) extension leads on H reel (black/green) with color-coded alligator clips, (1) extra black and green alligator clip, (6) BNC extension leads, (1) calibration loop, (3) C-clamps, a carrying case with wheels and handle for meters, carrying bag for meter and kit, (1) inverter 12 VDC to 120 VAC 200 watt (vehicle use) and user manual.

SHOWN: 6474 KIT

76 www.aemc.com

Technical Assistance (800) 343-1391
© Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved.

Vol. 23 Rev.00 02/2023

GROUND RESISTANCE TESTERS
GROUNDFLEX® FIELD KIT

FEATURES
· Ground Integrity Measurement
· 3- and 4-Point Fall-of-Potential measurement with manual or automatic frequency selection
· 4-Point soil resistivity measurement with automatic calculation of Rho (Ã) and user selection of the Wenner or Schlumberger test method
· 2- and 4-Wire DC resistance measurement (Bond testing) with automatic polarity reversal
· 3-Point Earth coupling measurement
· Automatic frequency scan from (41 to 5078) Hz for optimum test accuracy in electrically noisy environments
· Selectable test voltage limit of (10,16, 32, or 60) V with up to 250 mA of test current
· Automatic recognition of all electrode connections and measurement of their resistance value
· Determines bonding condition of overhead ground conductors
· Auto Power OFF management
· Optically isolated USB communication
· Remote set up and operation of all measurements using DataView® software supplied
· Rechargeable NiMH batteries from wall charger or vehicle power (Cat. #2135.43 needed for vehicle power)
· Rugged dustproof and water-resistant field case (IP53 rated in closed position)
· Includes DataView® software for data retrieval, real-time display, analysis, automatic report generation and system configuration

AUTOMATIC RECOGNITION AND DISPLAY OF INPUT CONNECTIONS TO MATCH TEST
The connections are displayed and flash if incorrect or absent for the test selected.

Overhead ground conductor
High voltage line

Current

injection

rod

RH

H

S

ES

E 6472

Potential measurement rod
RS

4 1
3 2

1 2 3 4
6474
4 AmpFlex® channels connected

GROUND MEASUREMENT ON TOWERS WITH GROUND CABLE
High-voltage lines are usually equipped with a ground cable to allow lightning to discharge to ground via the tower. As all the towers are connected to this conductor, all the tower's resistances are in parallel. This means it is impossible to measure tower resistance using traditional 3-Point methods unless the ground cable is disconnected, which is a dangerous and time-consuming operation.

ACCESSORIES

CAT #2135.87 GroundFlex® Sensor 32 ft (10 m) (Model 6474 only)

CAT #2135.72 Model SR182 AC Current Probe (Models 6471 & 6472)

CAT #2135.86 Lead ­ BNC 150 ft (46 m) M/F Extension Lead (Model 6474 only)

CATALOG NO. 2136.03

DESCRIPTION GroundFlex® Field Kit Model 6474 (Tower Tester)

Vol. 23 Rev.00 02/2023

Technical Assistance (800) 343-1391
© Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved.

www.aemc.com 77

GROUND RESISTANCE TESTERS
SELECTION CHART

AEMC MODEL NUMBER

AEMC CATALOG NUMBER

RESISTANCE RANGE

POWER SOURCE

2 POINT TEST

3 POINT TEST

4 POINT/ SELECTIVE

SOIL RESISTIVITY
TEST

EARTH COUPLING

2 CLAMP

BONDING DISPLAY

VOLTAGE INDUCTANCE SWEEP INDICATION INDICATION FREQUENCY

6416

2141.01

(0.01 to 1500) 

Battery

Clamp-On Ground Resistance Tester w/Alarm and Memory

­

ü ü** Digital Voltage

ü

­

6417

2141.02

(0.01 to 1500) 

Clamp-On Ground Resistance Tester

Battery

w/Alarm, Memory and

­

Bluetooth communication

Displayed

ü

ü (noise icon, ** Digital buzzer)

ü

­

6418

2141.03

(0.01 to 1200) 

Battery

Clamp-On Ground Resistance Tester w/Alarm and Memory

­

ü ü** Digital Noise Icon

­

6422

2135.55

0.05  to 50 k

Battery

ü

­

ü Digital Noise Icon

­

6422 Kit 150 FT

2135.56

0.05  to 50 k

Rechargeable Battery

ü

6424

2135.57

0.05  to 50 k

Rechargeable Battery

ü

­

ü Digital Noise Icon

­

­

ü Digital Noise Icon

­

6424 Kit 150 FT

2135.58

6424 Kit 300 FT

2135.59

GroundFlex® Field Kit 2136.03
Model 6474

6471

(SR182 probes

2135.48

not included)

6471 2135.49

6471 Kit 300 FT 2135.50 (with probes) 6471 Kit 300 FT 2135.60 (no probes) 6471 Kit 500 FT 2135.61 (no probes)

0.05  to 50 k
0.05  to 50 k
0.001  to 99.99 k
0.001  to 99.99 k
0.001  to 99.99 k
0.001  to 99.99 k
0.001  to 99.99 k
0.001  to 99.99 k

Rechargeable Battery
Rechargeable Battery
Rechargeable Battery
Rechargeable Battery
Rechargeable Battery
Rechargeable Battery
Rechargeable Battery
Rechargeable Battery

ü ü
­

­ ­
ü
ü ü ü ü ü

ü Digital Noise Icon ü Digital Noise Icon

­

ü Digital

Voltage Displayed

ü*** ü üü üü üü üü

Digital

Voltage Displayed

Digital Digital

Voltage Displayed
Voltage Displayed

Digital

Voltage Displayed

Digital

Voltage Displayed

­

­

­

ü

­

ü

­

ü

­

ü

­

ü

­

ü

6472

2135.51

0.001  to 99.99 k

Rechargeable Battery

6472 Kit 300 FT

2135.53

0.001  to 99.99 k

Rechargeable Battery

6472 Kit 500 FT

2135.54

0.001  to 99.99 k

Rechargeable Battery

4620

2130.43

(0.0 to 1999) 

Battery

ü

4620 Kit 150 FT

2135.19

(0.0 to 1999) 

Battery

ü

4620 Kit 300 FT

2135.20

(0.0 to 1999) 

Battery

ü

4620 Kit 500 FT

2135.21

(0.0 to 1999) 

Battery

ü

4630

2130.44

(0.0 to 1999) 

Rechargeable Battery

ü

4630 Kit 150 FT

2135.22

(0.0 to 1999) 

Rechargeable Battery

ü

ü

ü

ü

­

ü

­ ü*

­

ü

­

ü

­

ü

­ ü*

ü*** ü ü*** ü ü*** ü
­ ­ ­ ­ ­ ­

Digital Digital Digital

Voltage Displayed
Voltage Displayed
Voltage Displayed

Digital LED/Buzzer

Digital LED/Buzzer

Digital LED/Buzzer

Digital LED/Buzzer

Digital LED/Buzzer

Digital LED/Buzzer

­

ü

­

ü

­

ü

­

­

­

­

­

­

4630 Kit 300 FT

2135.23

(0.0 to 1999) 

Rechargeable Battery

ü

4630 Kit 500 FT

2135.24

(0.0 to 1999) 

Rechargeable Battery

ü

­
ü
­

­

Digital LED/Buzzer

­

­

Digital LED/Buzzer

­

* Performing soil resistivity tests with this kit requires two additional auxiliary electrodes not supplied in the 150 ft kit and one additional test lead. ** Clamp-on Ground Resistance Tester can measure system continuity inclusive of all bonding points. *** Must purchase an additional (2) SR182 or (2) MN82 accessory clamps.

78 www.aemc.com

Technical Assistance (800) 343-1391
© Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved.

Vol. 23 Rev.00 02/2023

LEAKAGE CURRENT METERS & PROBES
SEE WEBSITE FOR PRICING AND AVAILABILITY: WWW.AEMC.COM

LEAKAGE CURRENT METERS & PROBES
TRMS CLAMP-ON LEAKAGE CURRENT METER

MODEL 566
Designed to measure low AC currents, which are typically leakage currents in ground conductors

SPECIFICATIONS

MODEL ACmA Current (TRMS, Auto-Ranging)

Resolution

6 mA 60 mA 600 mA

Accuracy

(50 to 60) Hz (6 mA)

(50 to 60) Hz (60 and 600 mA)

(60 to 500) Hz (6 mA) (60 to 500) Hz (60 mA and 600 mA)

AC Current (TRMS, Auto-Ranging)

Resolution

6 A

60 A

Accuracy

(50 to 60) Hz (60 to 500) Hz

AC Voltage (TRMS)

Accuracy

60 V 600 V

DC Voltage

Resolution

60 V 600 V

Accuracy

60 V 600 V

Resistance

Accuracy

CONTINUITY

Frequency (Auto-Ranging)

Function

Resolution

(0 to 100) Hz 100 Hz to 1 kHz

Sensitivity

Accuracy

Filter MAX Sample Rate MECHANICAL Jaw Opening | Max Conductor Size Weight

Power Supply

ENVIRONMENTAL

Operating Temperature

SAFETY Safety Rating
Consult factory for NIST Calibration prices

566
0.001 mA (1 A) 0.01 mA (10 A) 0.1 mA (100 A) ± 1.0 % of Reading ± 8 cts ± 1.0 % of Reading ± 5 cts ± 2.0 % of Reading ± 8 cts ± 2.0 % of Reading ± 5 cts
1 mA 10 mA ± 1.0 % of Reading ± 5 cts ± 2.0 % of Reading ± 5 cts

± 1.0 % of Reading ± 3 cts

0.01 V 0.1 V
± 1.0 % of Reading ± 2 cts
(0 to 1) k ± 1.0 % of Reading ± 2 cts Buzzer activates < 45  (0 to 1) k

A-Hz

V-Hz

0.1 Hz 1 Hz

0.1 Hz 1 Hz

10 mArms min

5 Vrms min

± 0.5 % of Reading ± 2 cts

On (50/60) Hz only; Off (full frequency range)

100 ms

0.91 in (23 mm) 10.4 oz (296 g) with batteries (2) 1.5 V AAA batteries (included)

(32 to 104) °F (0 to 40) °C; < 80 % RH (non-condensing)

EN 61010-1, EN 61010-2-032, 600 V CAT III

PRODUCT INCLUDES

Soft carrying case, (2) color-coded (red/black) 5 ft test leads, (2) 1.5 V AAA (LR03) batteries and user manual.

Jaw Opening: .91 in (23 mm)
FEATURES
· Check for leakage and locate insulation breakdowns on live circuits
· Measures leakage current down to 0.001 mA with up to 1 A resolution
· Measures current up to 60 Arms · Measures up to 600 VAC/DC · Measures Hz on either V or A inputs · Measures resistance and continuity · Hold feature freezes value · MAX feature keeps track of highest measured
in-rush value · Zero button ideal for measuring relative values · Low pass filter to isolate (50/60) Hz fundamental
from harmonics · Compatible with VDE 0404 · Backlight LCD display
LOAD

CATALOG NO. 2139.83

DESCRIPTION TRMS Clamp-on Leakage Current Meter Model 566 (6/60/600 mA, 1/10/100 A, 600 VAC/DC, Hz, Ohms, Continuity)

80 www.aemc.com

Technical Assistance (800) 343-1391
© Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved.

Vol. 23 Rev.00 02/2023

LEAKAGE CURRENT METERS & PROBES
ARTIFICIAL NEUTRAL & LEAKAGE CURRENT PROBE

MODEL 2620
Check for leakage and locate insulation breakdowns on live circuits

SPECIFICATIONS

MODEL

2620

ELECTRICAL

4 A Range

400 A Range

Current Range

500 µA to 4 A

500 mA to 400 A

Output Signal

1 mV/mA (4 V max)

1 mV/A (400 mV max)

Accuracy

500 µA to 10 mA ± 3 % of Reading ± 1 mV

­

(10 to 100) mA ± 0.5 % of Reading ± 0.5 mV

­

100 mA to 4 A ± 0.5 % of Reading ± 0.5 mV

­

500 mA to 10 A

­

± 0.5 % of Reading ± 0.5 mV

(10 to 100) A

­

± 0.35 % of Reading ± 0.5 mV

10 A to 400 A

­

± 0.35 % of Reading ± 1 mV

Phase Shift

500 µA to 10 mA

­

(10 to 100) mA

< 15 °

­

100 mA to 4 A

< 10 °

­

500 mA to 10 A

­

(10 to 100) A

­

< 1 °

(100 to 400) A

­

< 0.6 °

Load Impedance

1 M min

Frequency Range

(48 to 1000) Hz

MECHANICAL

Dimensions

(11.22 x 6.89 x 1.77) in (285 x 175 x 45) mm

Weight

2.87 lb (1.3 kg)

Jaw Opening

4.4 in (112 mm)

Maximum Conductor Size

4.4 in (112 mm)

ENVIRONMENTAL

Operating Temperature

(-14 to 131) °F (-10 to 55) °C; Up to 85 % RH (non-condensing)

SAFETY

Safety Rating

EN 61010-2-032, 600 V CAT III

Consult factory for NIST Calibration prices

Jaw Opening: 4.4 in (112 mm) Conductor Size: 4.4 in (112 mm)
FEATURES
· Very high sensitivity · Differential or leakage current from 500 µA · Current up to 400 A · Two switch-selectable measurement ranges:
4 AAC/400 AAC · Large inside jaw diameter allows use on large or
multiple conductors · Works with single-, dual- and three-phase systems · Connect directly to DMMs on mV or VAC range

CATALOG NO. 2125.52

DESCRIPTION Leakage Current Probe Model 2620 (4 A, 1 V/A & 400 A, 1 mV/A output)

Vol. 23 Rev.00 02/2023

Technical Assistance (800) 343-1391
© Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved.

www.aemc.com 81

As a businesWseoaf rtehecoCmhamuivttinedArtonoeunxv®irognrmouepn,taolurepsrpoodnuscibtsiliatyre. backed by over 130 yeaOrusropfreoxdpuecrtiednecseigannsdaenxdcperlolednuccetiionnteasret abnadsemdeasurement instrumentsoannedsteanbcloismhipnagssa tbhaelalantceestbeinttweerneantieonnvailrosntamnednatradls, for quality econaonmd isca, faentyd. sWoeciarlecothnedibtiroannsdiynofuutcuarne tsroucsite!ties. We are the brand you can trust!

MEGOHMMETERS

DATA ANALYSIS AND REPORTING SOFTWARE

SEE PAGE 133 FOR MORE INFO ON DATAVIEW® SOFTWARE

CONFIGURE MEGOHMMETERS
MODELS 1060, 5060, 5070, 6526, 6534, 6550 & 6555
Print reports of all test results / Select test voltage and run tests from your PC with a simple click and execute process / Capture and display data in real-time / Retrieve data from the instrument's memory

SEE WEBSITE FOR PRICING AND AVAILABILITY: WWW.AEMC.COM

MEGOHMMETERS
500 V & 1000 V HAND-CRANKED

MODEL 6503
Designed for acceptance testing and preventive maintenance of wiring, cables, switchgear and motors

Ideal for use in areas affected by floods

SPECIFICATIONS

MODEL

6503

INSULATION TESTS

Test Ranges*

250 V 500 V 1000 V

(1 to 500) M (1 to 500) M (10 to 5000) M (5 G )

Short Circuit Current

5 mA (max)

Voltage Measurement/ Safety Check

(0 to 600) VAC

Accuracy (M)

± 2.5 % of Full Scale Length

Automatic Discharge

8 s/µF

Charge Time

250 V 500 V 1000 V

0.2 s/µF 0.5 s/µF 0.5 s/µF

RESISTANCE TESTS

Measurement Range

­

Test Current

­

Accuracy

­

CONTINUITY TESTS

Measurement Range

­

Test Current

­

Accuracy

­

SAFETY

Safety Rating

EN 61010-1, 600 V CAT II, 300 V CAT III

*DC test voltage generated in full across the entire measurement range.

Consult factory for NIST Calibration prices

PRODUCT INCLUDES
MODEL 6503 Soft carrying case, (3) color-coded (red/black/blue) leads and alligator clips, black test probe and a user manual.

IP 54
FEATURES
· True Megohmmeter® · No batteries or power needed to operate · Test voltages of (250, 500, and 1000) V · Insulation measurements to 5000 M · LED indicates constant voltage output and proper cranked
speed controlled by voltage regulator · Automatic discharge when measurement is finished · Auto-Ranging ­ dual scale operation for better sensitivity
and easier readings · Compact self-contained package; folded crank · Voltage displayed prior to, during and at the end of test · Large direct reading scale

CATALOG NO. 2126.52

DESCRIPTION Megohmmeter Model 6503 (Hand-cranked, 250 V, 500 V, 1000 V)

84 www.aemc.com

Technical Assistance (800) 343-1391
© Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved.

Vol. 23 Rev.00 02/2023

MEGOHMMETERS
1000 V DIGITAL

MODEL 6527
Insulation tester with DMM functions specially designed for testing wiring, small motors and other equipment

SPECIFICATIONS

MODEL

6527

Range INSULATION TESTS (250 V)

4 M

40 M

400 M 4000 M (4G )

Resolution Accuracy Test Current

0.001 M

0.01 M

0.1 M

1 M

±2 % of

±3 % of

±4 % of

Reading ±10 cts

Reading ±5 cts Reading ±5 cts

1 mA test current into a 250 k load

INSULATION TESTS (500 V)

Resolution Accuracy Test Current

0.001 M

0.01 M

0.1 M

1 M

±2 % of

±2 % of

±4 % of

Reading ±10 cts

Reading ±5 cts Reading ±5 cts

1 mA test current into a 500 k load

INSULATION TESTS (1000 V)

Resolution Accuracy Test Current

0.001 M

0.01 M

0.1 M

1 M

±3 % of

±2 % of

±2 % of

±4 % of

Reading ±10 cts Reading ±10 cts Reading ± 5 cts Reading ±5 cts

1 mA test current into a 1 M load

VOLTMETER RANGES (250 V, 500 V, & 1000 V)

V AC/DC

600 V

1000 V

Resolution
Accuracy DC AC
Input Impedence DC AC
RESISTANCE TESTS - OHMMETER

1 V
±0.8 % of Reading ±3 cts ±1.2 % of Reading ±10 cts
10 M 10 M (40/400) Hz

Range

(0 to 400) k

Resolution

0.1 k

Accuracy

±1.2 % of Reading ±3 cts

CONTINUITY TESTS

Range

(0 to 400) 

Resolution

0.01 

0.1 

Accuracy

1.2 % ±3 cts

Test Current

> 200 mA (0.2/2) 

Test Lead Compensation

Yes: Dedicated push-button

Beeper

Yes: < 35  ±3 

ELECTRICAL

Power Supply

(6) 1.5 V AA batteries ­ Alkaline recommended (included)

SAFETY
Safety Rating IP Protection

EN 61557, 600V Cat. IV IP51

Consult factory for NIST Calibration prices

PRODUCT INCLUDES
Soft carrying case, set of (2) 5 ft color-coded test leads with alligator clips, (1) black test probe and user manual.

IP 51
FEATURES
· True Megohmmeter® · Insulation test voltage selections of
(250, 500, and 1000) V · Measure insulation to 4000 M (4 G) · TEST LOCK feature for time sensitive
measurements up to 15 minutes · Auto discharge after insulation test · AC/DC voltmeter to 600 VAC/ 1000 VDC · Ohmmeter to 400 k · Continuity meter with > 200 mA test
current · Test lead resistance compensation for
accurate low resistance measurements · Auto HOLD function to "freeze" readings · Large and bright dual display with blue
backlight · Auto Power OFF feature · Ergonomic over-molded case with
back-stand

CATALOG NO. 2126.53

DESCRIPTION Megohmmeter Model 6527 (Digital 250 V, 500 V, 1000 V, Continuity, 400 k, V)

Vol. 23 Rev.00 02/2023

Technical Assistance (800) 343-1391
© Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved.

www.aemc.com 85

MEGOHMMETERS
1000 V DIGITAL & MULTI-FUNCTION HANDHELD

MODEL 6529 Insulation tester ideal for maintenance and repair operations on electrical equipment such as motors, cables, and more.

SPECIFICATIONS

US Design Patent US D890,617 S

MODEL

6529

AC/DC VOLTAGE MEASUREMENT

Range

700 VAC, 700 VAC+DC

Accuracy

DC AC+DC

± (1 % R + 1 ct) ± (1.2 % R + 1 ct)

Resolution

1 V

Frequency Range

DC & (30 to 440) Hz

Input Impedance

25 M

INSULATION MEASUREMENT

Test Voltage/Resistance Range 50 V 100 V
250 V 500 V 1000 V
Measurement Accuracy 40 /40 M/400 M 4.2 G 11 G

(0.010 to 420.0) M (0.020 to 420.0) M (0.050 to 4200) M (0.100 to 4200) M 0.20 M to 11.00 G
± (1.5 % R + 10 ct) ± (4 % R + 10 ct) ± (10 % R + 10 ct) (1000 V range)

CONTINUITY MEASUREMENT

Range

(0 to 40)  (200 mA test current  2 )

Accuracy

1.2 % R +3 ct

Resolution Max

0.01 

Leads Compensation

Up to 5 

Threshold

Audible signal triggered, Selectable  1  or 2 

RESISTANCE MEASUREMENT

Range

(0 to 420) k (Auto ranging)

Accuracy

± (1.2 R + 3 ct)

Resolution Max

0.1 

DMR Mode

Compares successive measurements to a reference value with alarm indication and red backlit display if deviation changes by the programmed %. The difference between the new reading and the reference measurement,
along with the % deviation is displayed.

GENERAL

Time Test

10 s to 39.59 min selectable

Display

LCD with backlight

Power Supply

(6) AA alkaline batteries (NEDA 15 A or IEC LR6)

Battery Life (5 s ON, 25 s OFF)

> 2000 measurement in M, > 300 h in VAC/DC, > 6000 measurement in Continuity Test

Dimensions

(8.54 x 3.54 x 2.44) in (217 x 90 x 62) mm

Weight

1.68 lb (762 g)

Operating Temperature

(14 to 122) °F (-10 to 50) °C, 90 % RH

SAFETY

Safety Rating

IEC / EN 61010-1, 600 V CAT IV, CE mark

®

C

US

LISTED

Consult factory for NIST Calibration prices

PRODUCTS INCLUDE
Includes soft carrying case, set of (2) 5 ft color-coded (red/black) silicone leads and alligator clips, (2) color-
coded (red/black) test probes (Rated 1000 V CAT IV, UL V2), (6) 1.5 V AA batteries and user manual.

IP 40 with leads connected
FEATURES
· Selectable test voltages (50, 100, 250 , 500 and 1000) V
· Basic DMM functions; Volts, Continuity, Resistance
· DAR and PI ratio test functions
· Dual line display to view the insulation value and real-time test voltage simultaneously in an easy-to-read format
· DMR mode - relative resistance comparison to a reference value
· 2-color backlighting easily shows alarm conditions
· Shockproof sheath for excellent handling
· Automatic power-off function to optimize the battery life
· Programmable alarm thresholds

ACCESSORIES/REPLACEMENTS

Catalog #2138.54 Continuity probe
Catalog #2119.02 Soft carrying pouch
Catalog #2971.04 Fuse ­ Set of (2) FF, 200 mA, 1000 V, 10 kA, (6 x 32) mm
Catalog #5000.94 Lead ­ Set of (2) 5 ft color-coded (red/ black) silicone leads with 4 mm straight/ right angle banana plugs (Rated 1000 V CAT IV, UL)

Catalog #5000.97/#5000.98 Black/red test probe (1000 V CAT IV, 15 A, UL V2)
Cat #5000.99/#5100.00 Clip ­ Safety alligator (black/red) (1000 V CAT IV, 15 A, UL V2)

CATALOG NO. 2126.55

DESCRIPTION Megohmmeter Model 6529 (Digital, 50 V, 100 V, 250 V, 500 V, 1 kV, 420 k-Ohm, Continuity, Alarm, Timer & PI/DAR)

86 www.aemc.com

Technical Assistance (800) 343-1391
© Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved.

Vol. 23 Rev.00 02/2023

MEGOHMMETERS
DIGITAL/ANALOG & MULTI-FUNCTION HANDHELD

MODELS 6522, 6526, 6534 & 6536
6522 & 6526 - ideal for testing cables, small motors, pumps, transformers and industrial equipment
6534 - ideal for insulation measurements on communication cables, Ethernet cables and other low voltage DC wiring
6536 - ideal for special applications in the aerospace and defense sectors and for ESD testing where specific test voltages are required

6522

6526

SPECIFICATIONS

MODELS

6522

6526

6534

6536

INSULATION TESTS

Test Voltages

(250, 500, and 1000) V

(50, 100, 250, 500, and 1000) V

(10, 25, 100, 250, and 500) V

Variable (10 to 100) V (1 V steps)

Insulation Resistance

40 G (40,000 M) 200 G (200,000 M)

50 G (50,000 M)

20 G (20,000 M)

PI/DAR Ratios

No

Yes

No

Test Lock

Yes

Timer

(0 to 40) min

Auto Discharge

Yes

Automatic Test Inhibit

> 25 V

DMM FUNCTIONS

6534

Voltage

700 VAC/DC

Resistance

­

1000 k

Continuity

10 

10 , 100 

Test Current

200 mA

Capacitance Measurement

­

0.1 n to 10 µF

­

Frequency

­

GENERAL FUNCTIONS

Alarm /  Rel

NO/NO

Auto Power OFF

Data Hold

Test Lead Compensation

Remote Probe

Memory

­

Bluetooth

­

DataView® Software

­

Display Type

Display Counts

Backlight

Power Supply

Magnetic Mount

SAFETY

Safety Rating

Consult factory for NIST Calibration prices

(15.3 to 800) Hz

­

Yes / Yes

Yes

Yes (optional)

1300 measurements

­

2.1 Class II

­

Included

­

Digital w/Analog Bargraph

4000

Yes

(6) AA Alkaline

Yes

600 V CAT IV

6536
6526 & 6534 (only)
IP 54

CATALOG NO. 2155.51 2155.53
2155.55 2155.56 2155.57

DESCRIPTION
Megohmmeter Model 6522 (Digital w/Analog Bargraph, 250 V, 500 V, 1000 V, Continuity, V) Megohmmeter Model 6526 (Digital w/Analog Bargraph, Alarm, 50 V, 100 V, 250 V, 500 V, 1000 V, Ohm, Continuity, V, k, Capacitance, Memory, Bluetooth w/DataView® software) Megohmmeter Model 6534 (Digital w/Analog Bargraph, Alarm, 10 V, 25 V, 100 V, 250 V, 500 V, Ohm, Continuity, V, k, Memory, Bluetooth w/DataView® software) Megohmmeter Model 6536 (Digital w/Analog Bargraph, Alarm, Variable (10 to 100) V, Ohm, Continuity, V, k)
Megohmmeter Model 6536 ESD Floor Kit (Meter, set of (2) 5 lb weights and carrying case)

Vol. 23 Rev.00 02/2023

Technical Assistance (800) 343-1391
© Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved.

www.aemc.com 87

MEGOHMMETERS
DIGITAL/ANALOG & MULTI-FUNCTION HANDHELD
MODELS 6522, 6526, 6534 & 6536

FRONT PANEL & FUNCTIONAL DISPLAYS
Analog with bargraph display of insulation resistance Secondary display
Main display
Function indicators
PRODUCT INCLUDES
6522 Soft carrying case, (2) 5 ft color-coded (red/black) leads, (2) color-coded (red/black) alligator clips, (1) black test probe, (6) AA batteries and user manual. 6526 Soft carrying case, (2) 5 ft color-coded (red/black) leads, (2) color-coded (red/black) alligator clips, (1) black test probe, (6) AA batteries, quick start guide, USB stick with DataView® software and user manual. 6534 Soft carrying case, (2) 5 ft color-coded (red/black) leads, (2) color-coded (red/black) alligator clips, (1) black test probe, (2) color-coded (red/black) grip probes, (6) AA batteries, quick start guide, USB stick with DataView® software and user manual. 6536 Soft carrying case, (2) 5 ft color-coded (red/black) leads, (2) color-coded (red/black) alligator clips, (1) black test probe, (2) color-coded (red/black) grip probes, (6) AA batteries, and user manual. 6536 ESD FLOOR KIT Field case, (2) 5 ft color-coded (red/black) leads, (2) color-coded (red/ black) alligator clips, (1) black test probe, (2) color-coded (red/black) grip probes, (2) 5 lb weights with conductive rubber bottom pad, (2) 4 mm non-insulated adapters, (6) AA batteries, and user manual.
SHOWN: 6526

Access to the instrument
information and setup for Test Lock, Timer, PI/DAR and Times
Navigation buttons: · Display instrument
information
· Turn buzzer ON or OFF · Turn power saver ON or OFF · Program test time · Select displayed parameters
· Program alarm set points
Memory recall/ Bluetooth activation
Alarm activation/deactivation with Pass/Fail indication
(model dependent)

Test lead resistance compensation Rel set and compare measurements to a reference value
Test button
Test function selection switch

IP 54
6526, 6532 & 6534
FEATURES*
· True Megohmmeter® · Test voltage from (10 to 1000) V · Insulation resistance up to 200 G · Manual, Lock, Timer modes & PI/DAR Ratio calculations · Alarms with Green/Red Pass/Fail indicator light · 200 mA/20 mA continuity with active protection without fuses · Measurement of V (TRMS & DC), F, , k, Hz, C · Rel mode for comparison measurements · Configurable alarms · Data retrieval · Automatic discharge after test · Automatic test inhibit if device under test is energized > 25 V

* Features are model dependent. Bluetooth on selected models.

88 www.aemc.com

Technical Assistance (800) 343-1391
© Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved.

Vol. 23 Rev.00 02/2023

MEGOHMMETERS
1000 V DIGITAL/ANALOG

MODEL 1060 Test insulation on cables, transformers, motors and wiring installations

SPECIFICATIONS

MODEL

1060

INSULATION TESTS

Test Voltage

50 V 100 V 250 V 500 V 1000 V

Accuracy 2 k to 40 G 40 G to 4 T

Voltage Test/Safety Check

Voltage Warning Indicator

Test Inhibition

Smooth Function

RESISTANCE TESTS

Measurement Range

Test Voltage

Test Current

Accuracy

> 4 k

CONTINUITY TESTS

Measurement Range

Test Current

Accuracy

COMMUNICATION

Memory of Reading over Time R(t)

Memory of Test Results in Files

PC Software/Report Generation

ELECTRICAL

2 k to 200 G 4 k to 400 G 10 k to 1000 G (1 T) 20 k to 2000 G (2 T) 40 k to 4000 G (4 T)
± 5 % of Reading ± 3 cts ± 15 % of Reading ± 10 cts
(0 to 1000) VAC/DC > 25 V
Yes > 25 V Yes
0.01  to 400 k 12.4 VDC max < 6 mADC
± 3 % of Reading ± 3 cts
(0.01 to 39.99)   200 mA from (0.01 to 20.00) 
± 3 % of Reading ± 4 cts
Yes (128 kB memory)
128 kB memory with RS-232 to USB adapter (included)
DataView® (included)

Power Supply
SAFETY Safety Rating

9.6 V NiMH Battery Pack (included) (85 to 256) V ((50/60) Hz)
EN 61010-1, 600 V CAT III, EN 61557

Consult factory for NIST Calibration prices

PRODUCT INCLUDES
Detachable accessory pouch, (2) 5 ft color-coded (red/blue) leads, (1) black shielded lead, (3) color-coded (red/black/blue) alligator clips, (1) black test probe, (1) RS-232 DB9 F/F 6 ft null model cable, (1) RS-232 to USB adapter, US 115 V power cord, rechargeable NiMH battery, spare fuses, and a USB drive with DataView® software and user manual.

IP 54
FEATURES
· True Megohmmeter® · Test voltage selections of (50, 100, 250, 500 and 1000) V · Insulation measurements to 4000 G (4 T) · Direct measurement of DAR and PI values · Direct measurement of sample capacitance · Display of test voltage and run time · Programmable test run times and PI times · Smooth and Alarm functions · Automatic test inhibition (if live sample > 25 V) · Automatic discharge and display of discharge voltage · Large dual display with time, voltage and measurement · Bright blue electroluminescent backlight · Auto Power OFF when not in use · Remote operation with optional test probe · Rugged, dual wall, water-resistant field case with
detachable lead/accessory pouch
ACCESSORIES
CATALOG #2155.75 Megohmmeter test probe (600 V CAT IV)

CATALOG NO. 2130.03

DESCRIPTION
Megohmmeter Model 1060 (Digital, with Analog Bargraph, Backlight, Alarm, Timer, 50 V, 100 V, 250 V, 500 V, 1000 V, Auto DAR/ PI, Resistance, Continuity, DataView® software, 128 kB Memory)

Vol. 23 Rev.00 02/2023

Technical Assistance (800) 343-1391
© Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved.

www.aemc.com 89

MEGOHMMETERS
5000 V DIGITAL/ANALOG

MODEL 6505
Contributes to the safety of electrical installations and equipment

SPECIFICATIONS

MODEL INSULATION TESTS

Test Voltage/Range

500 V 1000 V 2500 V 5000 V

User Programmable Test

Short Circuit Current
Accuracy 10 k to 399.9 G 400 G to 10 T
DAR (1 min / 30 s)
PI (10 min / 1 min & User Programmable)

Capacitance Measurement

Leakage Current Measurement
Programmable PI Ratio Times Discharge After Test Discharge Voltage Display

Voltage Test / Safety Check

Voltage Warning Indicator Test Inhibition Guard Terminal ELECTRICAL

Power Supply

SAFETY Safety Rating
Consult factory for NIST Calibration prices

6505
10 k to 2000 G (2 T) 10 k to 4000 G (4 T) 10 k to 10,000 G (10 T) 10 k to 10,000 G (10 T) (40 to 1000) V: 10 V increments (1000 to 5100) V: 100 V increments < 1.6 mA ± 5 %
± 5 % of Reading ± 3 cts ± 15 % of Reading ± 10 cts
0.02 to 50.00
0.02 to 50.00
(0.001 to 49.99) µF; Max resolution 1 nF
0.00 nA to 3 mA; Max resolution 1 pA
(1 to 60) min Yes, automatic
Yes 2500 VAC / 4000 VDC (16 to 42) Hz / 1 V Resolution
Yes > 25 V > 40 % of test voltage
Yes
(1) 9.6 V NiMH battery pack (included); Line power: (85 to 256) VAC (50/60) Hz
EN 61010-1, 1000 V CAT III

ACCESSORIES/REPLACEMENTS
CATALOG #2133.73 Extra Large Tool Bag CATALOG #2960.21 9.6 V rechargeable NiMH battery pack CATALOG #2151.30 Lead ­ Replacement set of (3), 10 ft (5 kV) color-coded safety with clips (Jumper lead not included). CATALOG #2151.31 Lead ­ Replacement 1 ft jumper lead (blue) CATALOG #2151.32 Lead ­ Set of (3), 25 ft (5 kV) safety with clips CATALOG #2119.84 Fuse ­ Set of (3), 0.1 A, 380 V, 5 x 20, 10 kA CATALOG #5000.14 Power Cord 115 V US Plug

IP

FEATURES

53

· True Megohmmeter®

· Simple operation

· Test voltage selections of (500, 1000, 2500 and 5000) V

· Insulation measurements from 10 k to 10,000 G (10 T)

· Adjustable and programmable test voltage (40 to 5100) V

· Automatic calculation of DAR and PI values

· Direct measurement and display of capacitance and leakage current

· Display resistance, test voltage and run time

· Programmable PI ratio times

· Automatic test inhibition (if live sample > 40 % of test voltage)

· Automatic discharge and display of discharge voltage

· Large backlight LCD dual-display with time, voltage and measurements shown

· Rugged, dual wall, water-resistant field case

· Designed and built to IEC safety standards

PRODUCT INCLUDES
Extra large classic tool bag, set of (3) 10 ft color-coded (red/ black/blue) leads with clips (5000 V) (red/black/blue), (1) blue guard terminal jumper lead, fuse 0.1 A 380 V, rechargeable battery pack (installed), US 115 V power cord, and user manual.

CATALOG NO. DESCRIPTION

2130.18

Megohmmeter Model 6505 (Digital, with Analog Bargraph, Backlight, 500 V, 1000 V, 2500 V, 5000 V, Auto DAR/PI)

90 www.aemc.com

Technical Assistance (800) 343-1391
© Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved.

Vol. 23 Rev.00 02/2023

MEGOHMMETERS
5000 V DIGITAL/ANALOG

MODELS 5050 & 5060
Designed with the highest level of built-in safety features

SPECIFICATIONS

MODELS

INSULATION TESTS

Test Voltage

500 V 1000 V 2500 V 5000 V

User Selectable Test Voltage

Accuracy

10 k to 399.9 G 400 G to 10 T

Voltage Test/Safety Check

Voltage Warning Indicator

Test Inhibition

Smooth Function (user selectable) COMMUNICATION Storage of Readings over Time R(t) Storage of Test Results

Communication Port

PC Software/Report Generation ELECTRICAL Power Supply

SAFETY Safety Rating
Consult factory for NIST Calibration prices

5050

5060

10 k to 2000 G (2 T) 10 k to 4000 G (4 T) 10 k to 10,000 G (10 T) 10 k to 10,000 G (10 T)
Programmable: (40 to 1000) V: 10 V increments; (1000 to 5100) V: 100 V increments
± 5 % of Reading ± 3 cts ± 15 % of Reading ± 10 cts
2500 VAC/4000 VDC
Yes > 25 V
Yes ­ selectable at (3, 10, or 20) % of test voltage
Digital filtering stabilizes display readings

4 kB memory 20 readings
­
­

128 kB memory
1500 readings
Serial and RS-232 to USB adapter (included)
DataView® (included)

(1) 9.6 V NiMH battery pack (included) Line power: (85 to 256) V (50/60) Hz

EN 61010-1, 600 V, CAT III 1000 V

ACCESSORIES/REPLACEMENTS
CATALOG #2119.45 PC RS-232 DB9 F/F 6 ft Null Modem Cable (5060 & 5070) CATALOG #2119.84 Fuse, set of (3), 0.1 A, 380 V, 5 x 20, .10 kA CATALOG #2133.73 Extra Large Classic Tool Bag (18 x 9 x 12) in CATALOG #2135.43 Inverter ­ 12 VDC to 120 VAC 200 Watt for Vehicle use CATALOG #2136.80 Cable ­ 10 ft USB Cable CATALOG #2140.46 Cable - 5 ft USB A-B Cable CATALOG #2151.30 Lead ­ Replacement set of (3), 10 ft (5 kV) color-coded safety with clips (Jumper lead not included) CATALOG #2151.31 Lead ­ Replacement 1 ft jumper lead (blue) CATALOG #2151.32 Lead ­ Set of (3), 25 ft (5 kV) safety with clips CATALOG #2960.21 Battery ­ Rechargeable 9.6 V CATALOG #5000.60 Adapter RS-232 to USB 2.0 (5060 & 5070) CATALOG #5000.14 US 115 V Power Cord USB THUMB DRIVE Supplied with DataView® software and user manual (5060 & 5070)

5050

5060

SAFETY

IP

R ATIN G

53

FEATURES

5060 only

· True Megohmmeter®

· Test voltage selections of (500, 1000, 2500, and 5000) V

· Variable test voltage from (50 to 5100) V (model 5060)

· Wide measurement range up to 10 T

· Automatic discharge at the completion of the test

· Measure AC voltage up to 4000 V

· Automatic test inhibit if live voltage detected above a set value

· Programmable alarms for all functions

· Automatic calculation of DAR, PI and DD ratios

· Large, backlit LCD screen with digital display and bargraph

· Measures capacitance up to 49.99 µf

· Stores up to 1500 measurements (model 5060)

· Includes DataView® software for data retrieval, real-time display, analysis and report generation

PRODUCT INCLUDES
5050, 5060 & 5070 Extra large classic tool bag, set of (3) 10 ft (5 kV) safety leads (red/ black/blue) with clips, one guard terminal jumper lead (blue), US 115 V power cord, rechargeable battery pack, and user manual (5050)

CATALOG NO. 2130.20
2130.21

DESCRIPTION
Megohmmeter Model 5050 (Digital, Analog Bargraph, Backlight, Alarm, Timer, 500 V, 1000 V, 2500 V, 5000 V, Auto DAR/PI/DD) Megohmmeter Model 5060 (Digital, Analog Bargraph, Backlight, Alarm, Timer, 500 V, 1000 V, 2500 V, 5000 V, Auto DAR/PI/DD, USB w/DataView® Software)

Vol. 23 Rev.00 02/2023

Technical Assistance (800) 343-1391
© Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved.

www.aemc.com 91

MEGOHMMETERS
5000 V GRAPHICAL

MODEL 5070

Offers real-time graphic plot of measurements

and digital presentation of test results

SAFETY

SPECIFICATIONS

IP

R ATIN G

53

MODEL

5070

INSULATION TESTS

Test Voltage

500 V 1000 V 2500 V 5000 V

10 k to 2000 G (2 T) 10 k to 4000 G (4 T) 10 k to 10,000 G (10 T) 10 k to 10,000 G (10 T)

FEATURES
· True Megohmmeter®

User Selectable Test Voltage

Programmable: (40 to 1000) V: 10 V increments;
(1000 to 5100) V: 100 V increments

· Test voltage selections of (500, 1000, 2500, and 5000) V · Insulation measurements from 10 k to 10,000 G (10 T)

Automatic Step Voltage
Accuracy 10 k to 99.9 G 400 G to 10 T
Voltage Test/Safety Check Voltage Warning Indicator

Programmable step voltage and duration up to five steps.
Three profiles can be stored.
± 5 % of Reading ± 3 cts ± 15 % of Reading ± 10 cts
2500 VAC/4000 VDC Yes > 25 V

· Selectable and programmable test voltage (40 to 5100) V · Automatic calculation of DAR, PI and DD ratios · Calculations of Step Voltage through front panel · Direct measurement and display of capacitance and leakage current · Display resistance, test voltage and run time · Programmable test run times and PI ratio times

Test Inhibition
Smooth Function (user selectable) COMMUNICATION

Yes -- selectable at (3, 10, or 20) % of test voltage
Digital filtering stabilizes display readings

· Smooth and Alarm functions
· Automatic test inhibition (if live sample > (3, 10, or 20) % of test voltage)
· Automatic discharge and display of discharge voltage

Storage of Readings Over Time R(t) Storage of Test Results
Communication Port
PC Software/ Report Generation ELECTRICAL

128 kB memory
Stores over 1500 test results Serial and RS-232 to USB adapter (included)
DataView® (included)

· Graphic and digital display of test voltage, resistance and more · Bright blue electroluminescent backlight · Programmable temperature compensation · Programmable test voltage lock-out · Programmable alarm setting · Auto Power OFF when not in use

Power Supply
SAFETY Safety Rating

(1) 9.6 V NiMH battery pack (included) Line power: (85 to 256) V (50/60) Hz
EN 61010-1, 1000 V CAT III

Consult factory for NIST Calibration prices

· AC or DC powered with rechargeable NiMH battery pack - run while charging
· Rugged, water-resistant field case
· Includes DataView® software for data retrieval, real-time display, analysis and report generation

With the push of a button: Insulation Resistance measurement is graphically displayed at the completion of the test.

ACCESSORIES/REPLACEMENTS

CATALOG #2119.45 PC RS-232 DB9 F/F 6 ft Null Modem Cable (5060 & 5070) CATALOG #2119.84 Fuse, Set of (3), 0.1 A, 380 V, (5 x 20) mm, .10 kA CATALOG #2140.46 Cable - 5 ft USB A-B Cable
CATALOG #2133.73 Extra large classic tool bag (18 x 9 x 12) in CATALOG #2135.43 Inverter ­ 12 VDC to 120 VAC 200 Watt for Vehicle use
CATALOG #2136.80 Cable ­ 10 ft USB Cable

CATALOG #2151.30 Lead ­ Replacement set of (3), 10 ft (5 kV) color-coded safety with clips (Jumper lead not included) CATALOG #2151.31 Lead ­ Replacement 1 ft jumper lead (blue) CATALOG #2151.32 Lead ­ Set of (3), 25 ft (5 kV) safety with clips CATALOG #2960.21 Battery ­ Rechargeable 9.6 V CATALOG #5000.14 US 115 V Power Cord

CATALOG NO. 2130.30

DESCRIPTION
Megohmmeter Model 5070 (Graphical, Analog Bargraph, Backlight, Alarm, Timer, 500 V, 1000 V, 2500 V, 5000 V, Step V, Auto DAR/PI/DD, USB with DataView® software)

92 www.aemc.com

Technical Assistance (800) 343-1391
© Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved.

Vol. 23 Rev.00 02/2023

MEGOHMMETERS
10,000 V / 15,000 V DIGITAL

MODELS 6550 & 6555 Expert tools for testing insulation safely and accurately

Ideal for use on rotating machinery, transformers and cables operating at higher voltages

SPECIFICATIONS

MODELS

INSULATION TESTS

Test Voltage

500 V 1000 V 2500 V 5000 V 10,000 V

15,000 V

Fixed Test Voltages

Variable Voltages
Ramp Mode
Ramp Configuration Range
Step Mode Voltage Test/Safety Test Capacitance Measurement Leakage Current Measurement Discharge After Test Additional Test Stop Modes
I-Limit Early-Break
Timer Burn Mode Ratio Calculation Calculation of R at ref. T° Measurement Display Filter Graphs on Display Storage Communication
Power Supply
Battery Charging
Dimensions/Weight
SAFETY Safety Rating EMC/Mechanical Protection/Altitude

6550

6555

10 k to 2000 G (2 T)

10 k to 4000 G (4 T)

10 k to 10,000 G (10 T)

10 k to 15,000 G (15 T)

10 k to 25,000 G (25 T)

--

10 k to 30,000 G (30 T)

(500, 1000, 2500, 5000, and

(500, 1000, 2500, 5000,

10,000) V

10,000, and 15,000) V

Variable: (40 to10) KV

Variable: (40 to 15) KV

with three user programmable with three user programmable

voltage schemes

voltage schemes

Programmable ramps: start voltage/end voltage/duration

(40 to 1100) V /

(40 to 1100) V /

(500 to 10,000) V

(500 to 15,000) V

Up to 10 steps (voltage and duration configurable for each step)

2500 VAC to 4000 VDC

(0.005 to 19.99) µF

(0 to 10) mA

Yes/Automatic

Programmable: (0.2 to 5) mA di/dt
Up to 99 m 59 s Constant testing
PI, DAR, DD
Yes
3 filters with 3 possible time-constants
R(t)+V(t); I(t); I(V)
256 registers, stores 80,000 points: R, V, I and date
USB optically-isolated port NiMH rechargeable batteries, (2) 9.6 V 4 A·h battery packs charging by external voltage: (90 to 260) V; (50/60) Hz Battery charging allowed while performing insulation measurements
(13.39 x 11.81 x 7.87) in (340 x 300 x 200) mm / approx. 13.7 lb (6.2 kg)

1000 V CAT IV; IEC61010-1 and IEC 61557 EN 61326-1/IP54/2000 m

Consult factory for NIST Calibration prices

PRODUCT INCLUDES

Small classic tool bag, set of (3) 10 ft color-coded (red/blue/black) safety leads with clips (3000 V CAT III), (1) 15 kV jumper lead (blue), optical USB cable, 115 V US power cord, 9.6 V rechargeable NiMH batteries, and a USB drive with DataView® software and user manual.

CATALOG NO. DESCRIPTION

2130.31

Megohmmeter Model 6550 (Graphical, Analog Bargraph, Backlight, Alarm, Timer, 500 V, 1000 V, 2500 V, 5000 V, 10 kV, Ramp, StepV, Variable, Auto DAR/PI/DD, USB, w/DataView® Software)

2130.32

Megohmmeter Model 6555 (Graphical, Analog Bargraph, Backlight, Alarm, Timer, 500 V, 1000 V, 2500 V, 5000 V, 10 kV, 15 kV, Ramp, StepV, Variable, Auto DAR/PI/DD, DataView® software)

IP 54
FEATURES
· True Megohmmeter® · Fixed or programmable test voltage from
40 V to 10 kV/15 kV · Wide measurement range from 10 k
to 25 T/30 T · 5 mA short circuit current · Step and Ramp voltage testing · Automatic calculation of DAR / PI / DD /R
(ppm/V) ratios · Large, backlit graphical LCD screen with
digital display, bargraph and R(t)+V(t), I(t) and I(V) graphs · Multiple test modes: voltage ramp and step with "Burn-In", "Early-Break" and "I-Limit" modes · Three filter settings to optimize measurement stability · Calculation of R at a reference temperature · Storage of 80,000 measurements · Includes DataView® software for data retrieval, real-time display, analysis and report generation · Optically-isolated USB communication for transfer onto PC and report generation with DataView® software
ACCESSORIES/REPLACEMENTS
CATALOG #2133.72 Small classic tool bag CATALOG #2135.41 Optical USB cable CATALOG #2140.19 (1) 9.6 V NiMH battery (two required) CATALOG #2151.36 Lead ­ Set of (3) color-coded (red/black/blue) 10 ft safety leads w/clips (15 kV) CATALOG #2151.37 Lead ­ 1.5 ft blue jumper lead (15 kV) CATALOG #2151.38 Lead ­ Set of (3), 25 ft, 15 kV color-coded (red/blue/black) safety leads w/clips CATALOG #5000.32 Power cord - 240 V EU

Vol. 23 Rev.00 02/2023

Technical Assistance (800) 343-1391
© Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved.

www.aemc.com 93

MEGOHMMETERS
SELECTION CHART

AEMC MODEL NUMBER 6503 6522
6527 6529
6526
6534 6536 6536 ESD Floor Kit 1060
6505
5050
5060
5070
6550
6555

AEMC CATALOG NUMBER

TEST VOLTAGE

INSULATION RANGE

RESISTANCE CONTINUITY

RANGE

RANGE

2126.52 2155.51 2126.53 2126.55
2155.53
2155.55 2155.56 2155.57 2130.03 2130.18 2130.20 2130.21 2130.30 2130.31
2130.32

250 V (1 to 500) M

500 V (1 to 500) M

­

1000 V (10 to 5000) M

250 V 50 k to 10 G

500 V 100 k to 20 G

­

10 

1000 V 200 k to 40 G

250 V 500 V 1000 V

1 k to 4 G 1 k to 4 G 1 k to 4 G

400 k

400 

50 V (0.010 to 420) M

100 V (0.020 to 420) M

(0 to 40) 

250 V (0.050 to 420) M (0 to 420) k (200 mA test

500 V (0.100 to 4200) M

current  2 )

1000 V 0.20 M to 11 G

50 V 10 k to 10 G

100 V 250 V 500 V

20 k to 20 G 50 k to 50 G 100 k to 100 G

1000 k

10 , 100 

1000 V 200 k to 200 G

10 V

2 k to 1 G

25 V 100 V 250 V

5 k to 2 G 10 k to 10 G 50 k to 25 G

1000 k

10 , 100 

500 V 100 k to 50 G

10 V

100 V (variable in

2 k to 20 G

1000 k

10 , 100 

1 V steps)

50 V 2 k to 200 G

100 V 4 k to 400 G

250 V 10 k to 1 T

400 k

40 

500 V 20 k to 2 T

1000 V 40 k to 4 T

500 V 10 k to 2 T

1000 V 10 k to 4 T 2500 V 10 k to 10 T

­

5000 V 10 k to 10 T

500 V 10 k to 2 T

1000 V 10 k to 4 T 2500 V 10 k to 10 T

­

5000 V 10 k to 10 T

500 V 10 k to 2 T

1000 V 10 k to 4 T 2500 V 10 k to 10 T

­

5000 V 10 k to 10 T

500 V 10 k to 2 T

1000 V 10 k to 4 T 2500 V 10 k to 10 T

­

5000 V 10 k to 10 T

500 V 10 k to 2000 G

1000 V 10 k to 4000 G

2500 V 10 k to 10,000 G

­

5000 V 10 k to 15,000 G

10,000 V 10 k to 25,000 G

500 V 10 k to 2000 G

1000 V 10 k to 4000 G

2500 V 10 k to 10,000 G 5000 V 10 k to 15,000 G

­

10,000 V 10 k to 25,000 G

15,000 V 10 k to 30,000 G

CAPACITANCE RANGE
­ --
­
0.1 n to 10 µF
­
­
(0.005 to 4.999) µF
(0.001 to 49.99) µF (0.001 to 49.99) µF (0.001 to 49.99) µF (0.001 to 49.99)µF
(0.001 to 19.99) µF
(0.001 to 19.99) µF

Consult factory for NIST Calibration prices

VOLTAGE DETECTION

POWER SOURCE

DISPLAY

DATAVIEW® SOFTWARE

600 VAC

Hand-cranked Analog

No

700 VAC/DC

(6) AA Alkaline Digital/ Batteries Analog

No

600 VAC 1000 VDC

(6) AA Alkaline Digital/ Batteries Analog

No

700 VAC 700 VAC/DC

(6) AA Alkaline Batteries

Digital

No

700 VAC/DC

(6) AA Alkaline Digital/ Batteries Analog

Yes

700 VAC/DC

(6) AA Alkaline Digital/ Batteries Analog

Yes

700 VAC/DC

(6) AA Alkaline Digital/ Batteries Analog

No

1000 VAC/DC

Rechargeable NiMH Battery

Digital/ Analog

Yes

2500 VAC 4000 VDC

Rechargeable NiMH Battery

Digital/ Analog

No

2500 VAC 4000 VDC

Rechargeable NiMH Battery

Digital/ Analog

No

2500 VAC 4000 VDC

Rechargeable NiMH Battery

Digital/ Analog

Yes

2500 VAC 4000 VDC

Rechargeable NiMH Battery

Graphic/ Digital

Yes

2500 VAC 4000 VDC

Rechargeable NiMH Battery

Digital/ Analog

Yes

2500 VAC 4000 VDC

Rechargeable NiMH Battery

Digital/ Analog

Yes

94 www.aemc.com

Technical Assistance (800) 343-1391
© Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved.

Vol. 23 Rev.00 02/2023

MICRO-OHMMETERS

DATA ANALYSIS AND REPORTING SOFTWARE

SEE PAGE 133 FOR MORE INFO ON DATAVIEW® SOFTWARE

CONFIGURE MICRO-OHMMETER
MODELS 6240, 6255 & 6292
Customize views and templates / Configure test options / Display and print reports of all test results / Retrieve data from the instrument's memory

SEE WEBSITE FOR PRICING AND AVAILABILITY: WWW.AEMC.COM

MICRO-OHMMETERS
10 A

MODEL 6240
Auto calculates resistance from 5 µ to 400  with resolutions down to 1 µ

SPECIFICATIONS

MODEL
Range
Accuracy Resolution
Test Current
Max. Inductive Load Memory Power Supply

(5.0 to 3999) µ
1 µ 10.2 A ± 2 %

6240

(4.0 to (40.0 to (400 to (4.0 to (40.0 to

39.99) m 399.9) m 3999) m 39.99)  399.9) 

± 0.25 % of Reading ± 2 cts

10 µ 100 µ 1 m 10 m 100 m

1.02 A ± 2 %

102 mA ± 2 %

10.2 mA ± 2 %

0.5 H

Stores up to 99 test results Rechargeable 6 V, 8.5 A·h NiMH battery pack (included)

Consult factory for NIST Calibration prices

ACCESSORIES/REPLACEMENTS
CATALOG #1017.84 (Replacement) Kelvin Clips 10 ft (10 A - Hippo) CATALOG #2118.70 Kelvin Clips 20 ft (10 A - Hippo)
CATALOG #2118.73 (Replacement) Kelvin Probes 10 ft (1 A, Spring Loaded) CATALOG #2118.74 Kelvin Probes 20 ft (1 A, Spring Loaded)
CATALOG #2118.84 Kelvin Probes Pistol Grip 10 ft (25 A, Spring Loaded) CATALOG #2118.85 Kelvin Probes Pistol Grip 20 ft (25 A, Spring Loaded)
CATALOG #2118.77 Kelvin Probes 10 ft (10 A, Spring Loaded) CATALOG #2118.78 Kelvin Probes 20 ft (10 A, Spring Loaded)
CATALOG #2118.79 Kelvin Clips 10 ft (1-10 A) Replacement for Cat. #2118.71 CATALOG #2118.80 Kelvin Clips 20 ft (1-10 A) Replacement for Cat. #2118.72

PRODUCT INCLUDES
Extra large tool bag, set of (2) 10 ft Kelvin clips (10 A - Hippo), set of (2) 10 ft Kelvin probes (1 A - Spring Loaded), optical USB cable, US 115 V power cord, (2) spare fuses (12.5 A), NiMH 6 V rechargeable battery pack*, and USB drive with DataView® software and user manual.
*Can be charged during operation

IP

IP

64

53

cover closed cover open

FEATURES
· Reliable low resistance measurements from 5 µ to 400 
· Four-terminal Kelvin resistance measurement eliminates test lead resistance
· 10 A test current up to 4000 µ · ± 0.25 % basic accuracy · 1 µ resolution · Direct reading, easy to operate · Six selectable resistance ranges · Reverse polarity button · Overload and input fuse protection · Manufactured to international safety and
environmental standards · Automatic decimal point and zeroing · Large terminals accept banana plugs and
spaded lugs · Rechargeable NiMH battery with internal charger
(110/220 V). Can be charged during operation · Large multifunctional backlit display · Includes power cord and isolated USB cable · Includes DataView® software for data retrieval,
real-time display, analysis and report generation

CATALOG NO. 2129.80

DESCRIPTION
Micro-Ohmmeter Model 6240 (10 A, Instantaneous, Continuous, Multiple Test, includes 10 ft Kelvin Clips (10 A - Hippo-Cat #1017.84), 10 ft Kelvin Probes (1 A Spring Loaded, Cat #2118.73) and DataView® Software)

96 www.aemc.com

Technical Assistance (800) 343-1391
© Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved.

Vol. 23 Rev.00 02/2023

MICRO-OHMMETERS
10 A

MODEL 6255

Accurate results within 0.05 %

Provides extended test time at 10 Amps without overheating SPECIFICATIONS

IP 64
cover closed

MODEL Range
Accuracy
Resolution Test Current Measurement Mode Metal Type Alpha Alarms Memory Power Supply Battery Life

6255

5.0000 25.000 250.00 2500.0 25.000 250.00 2500.0

m

m

m

m







± 0.15 % of Reading +1.0 µ

± 0.05 % of Reading + 3 µ

± 0.05 ± 0.05

% of

% of

Reading Reading

+ 30 µ + 0.3 m

± 0.05 % of Reading + 3 m

± 0.05 ± 0.05

% of

% of

Reading Reading

+ 30 m + 300 m

0.1 µ 1 µ 10 µ 0.1 m 1 m 10 m 100 m

10 A

1 A 100 mA 10 mA 1 mA

Selectable: Inductive (continuous test), Resistive (instantaneous test) or Auto (multiple tests)

Selectable: copper, aluminum or other metal Programmable from 000.00 to 99.99

Two ­ programmable set points from (0.0 to 2500.0) 

Stores up to 1500 test results; data in memory can be reviewed on the instrument display, on a PC or via direct printout

Rechargeable 6 V, 8.5 A·h NiMH battery pack (included)

Approximately 5000 10 A tests

IP 53 cover open
FEATURES
· Measure from 1 µ (0.1 µ resolution) to 2500.0 
· Test current selection of (1, 10, and 100) mA, and (1 and 10) A
· RTD temperature probe to check tested sample (optional)
· Selectable metal types · Automatic and manual temperature correction

Consult factory for NIST Calibration prices

· Two programmable alarm set points

ACCESSORIES/REPLACEMENTS
CATALOG #1017.84 Kelvin Clips 10 ft (10 A - Hippo) CATALOG #2118.70 Kelvin Clips 20 ft (10 A - Hippo) CATALOG #2118.73 Kelvin Probes 10 ft (1 A, Spring Loaded) CATALOG #2118.74 Kelvin Probes 20 ft (1 A, Spring Loaded) CATALOG #2118.84 Kelvin Probes Pistol Grip 10 ft (25 A, Spring Loaded) CATALOG #2118.85 Kelvin Probes Pistol Grip 20 ft (25 A, Spring Loaded) CATALOG #2118.77 Kelvin Probes 10 ft (10 A, Spring Loaded) CATALOG #2118.78 Kelvin Probes 20 ft (10 A, Spring Loaded) CATALOG #2118.79 Kelvin Clips 10 ft (1-10 A) / Replacement for Cat. #2118.71 CATALOG #2118.80 Kelvin Clips 20 ft (1-10 A) / Replacement for Cat. #2118.72
CATALOG #2119.45 Cable, PC RS-232, DB9 F/F 6 ft Null Modem Cable
CATALOG #2129.95 RTD Temperature Probe (plug into faceplate for ambient temperature)
CATALOG #2129.96 RTD Temperature Probe with 7 ft extension cable

· Stores up to 1500 test results
· Selectable inductive or resistive test modes
· Automatic multiple test mode (multiple tests without pressing the test button)
· Large multi-line electroluminescent display
· Local or remote test setup and control
· Internal rechargeable batteries conduct up to 5000 ­ 10 A tests
· Rugged, double insulated watertight case · Includes FREE DataView® software for data retrieval,
real-time display, analysis and report generation
PRODUCT INCLUDES
Extra large tool bag, set of (2) 10 ft Kelvin Clips (10 A - Hippo), set of (2) 10 ft Kelvin Probes (1 A - Spring Loaded), RS-232 DB9 F/F 6 ft null modem cable, RS-232 to USB adapter, US 115 V power cord, NiMH rechargeable 6 V battery pack (installed in meter), quick start guide and a USB drive with DataView® software and user manual.
SHOWN: CAT. #2129.84

CATALOG NO. DESCRIPTION

2129.84

Micro-Ohmmeter Model 6255 (10 A, Instantaneous, Continuous, Multiple Test, Manual/Auto Temperature Compensation; includes 10 ft Kelvin Clips (10 A-Hippo, Cat #1017.84), 10 ft Kelvin Probes (1 A Spring Loaded, Cat #2118.73) and DataView® Software)

Vol. 23 Rev.00 02/2023

Technical Assistance (800) 343-1391
© Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved.

www.aemc.com 97

MICRO-OHMMETERS
200 A

MODEL 6292
Programmable test currents and test duration with data storage and report generation using included application software
Includes both sides grounded test feature

Case color may vary

SPECIFICATIONS

MODEL

6292

Electrical

Test Current Range Adjustable from (5 to 200) A (True DC)

Resistance Range

0.1 µ to 2 m

(2 to 200) m

200 m to 1 

Accuracy

± 1 % of reading from 50 µ to 1 

Resolution

0.1 µ to 2 m 2 m to 200 m
200 m to 1 

0.1 µ (5 to 200) A 10 µ (25 A @ 200 m)
1 m (5 A @ 1 )

Output Voltage

100 VAC: 4.2 V @ 200 A 220 VAC: 8.6 V @ 200 A

Max. Load Resistance

100 VAC: 20 m @ 200 A

220 VAC: 42 m @ 200 A

Measurement Method

Four-terminal, Kelvin-type

Adjustable Test Time

5 to 120 s or unlimited

Memory

Stores up to 8000 measurements

Power Supply

(100 to 240) VAC, (50/60) Hz

Consult factory for NIST Calibration prices

ACCESSORIES/REPLACEMENTS

CATALOG #2129.86 Current Probe MR6292

CATALOG #2129.72 Lead - Set of (2) 25 ft Kelvin clips (200 A - Hippo)

CATALOG #2129.73 Lead - Set of (2) 50 ft Kelvin clips (200 A - Hippo)

CATALOG #2129.88 Lead - 10 ft Earth/Ground (Green) with attached Clamp
CATALOG #5000.40 110 V US Power Cord

PROBE MR6292

IP 54 cover closed
FEATURES
· Adjustable test currents from (5 to 200) A · Programmable test duration from (5 to 120) seconds · BSG Ground Test with optional current probe · Incorporates True DC high output with minimum, near zero, ripple lower
than 2 % of full range · Accurately measures low contact resistance with test currents up to 200 A · Measures resistances from 0.1 µ to 1  · Low resolution of 0.1 µ · Cooling system to improve the number of sequential tests that can
be performed · Backlit display · Measures objects with both sides grounded · Stores up to 8000 test results · Direct printout of measurement results using DataView® software and a PC · Rugged and water-resistant case
PRODUCT INCLUDES
Extra large tool bag, set of (2) 25 ft Kelvin clips (200 A - Hippo), (1) ground lead (green) with clamp, 5 ft USB cable, 110 V US power cord, printed quick start guide and a USB thumb drive with DataView® software and user manual.

FRONT PANEL DISPLAY

Test Results Test Current
Date & Time

ò ñððþðð

ðIôtòõòñññððôòðññÿþú

ðñðIñõùúòõðøðöðþðñðñýs

Ground Current
Elapsed and Total Test Times

CATALOG NO. DESCRIPTION

2129.83

Micro-Ohmmeter Model 6292 (200 A, 120 V/230 V, DataView® Software)

98 www.aemc.com

Technical Assistance (800) 343-1391
© Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved.

Vol. 23 Rev.00 02/2023

OSCILLOSCOPESREMOVE 5022 ADD KIT ADD CAT# LINE AT BOTTOM
SEE WEBSITE FOR PRICING AND AVAILABILITY: WWW.AEMC.COM

OSCILLOSCOPES
HANDSCOPE

MODEL OX 5042B 3-in-1 Instrument: Oscilloscope, Multimeter and Power Harmonic Analyzer with two fully isolated channels; fits into one hand

SPECIFICATIONS

INTERFACE Display
Commands
Display Mode Display of Curves on Screen Integrated Interactive Help Function OSCILLOSCOPE MODE Vertical Deflection Bandwidth Bandwidth Limiter Number of Channels Input Impedance Maximum Input Voltage Vertical Sensitivity Horizontal Deflection Sweep Speed Horizontal Zoom Triggering Mode Type Coupling Sensitive Digital Memory Maximum Sampling Rate Vertical Resolution Memory Depth User Storage GLITCH Mode Display Modes Other Functions Math Functions Cursor Measurement Automatic Measurement Multimode Mode General Specifications Operating Modes AC, DC & AC+DC Voltages Resistance Capacitance Other Measurements POWER Measurements Harmonic Analyzer Mode Multi-Channel Analysis Simultaneous Measurements GENERAL Screenshots PC Communication
Power Supply
Safety/EMC

3.5 in color TFT LCD screen; Resolution (320 x 240) pixels ­ LED backlighting Direct adjustments on front panel & on-screen menus via browser (principal & secondary without "hidden menus") 2500 real acquisition points on screen
2 curves + 2 references + memory trace or mathematical calculation
14 complete languages, menus and online help

IP 54
3 YEAR WARRANTY

40 MHz 1.5 MHz, 5 kHz 2 fully isolated channels 1 M ± 0.5 %, approx. 17 pF 600 V ­ Derating -20 dB per decade from 100 kHz 5 mV to 200 V/div
25 ns/div to 200 s/div ­ Roll Mode from 100 ms to 200 s/div Zoom factor: x1, x2, x5
Automatic, triggered, one-shot & triggered roll Edge, pulse width (20 ns ­ 20 s)
AC or DC (depending on the coupling of the triggering channel) HF, LF or noise rejection  1.2 divisions p-p up to 40 MHz
2 Gs/s in ETS mode ­ 50 MS/s in one-shot mode on each channel 9 bits
2500 points per channel 2 MB for storing files: trace (.trc), text (.txt), configuration (.cfg), image files (.bmp)
Duration  20 ns ­ 1250 min / max pairs Envelope, Averaging (factors 2 to 64) and XY (vector)
Channel inversion, addition, subtraction, multiplication and division (adjustable scaling) 2 cursors: V, T, dV, dt simultaneously ­ 4-digit display resolution 18 time or level measurements and phase measurement
2 channels, 8000-count display + min / max bargraph ­ Graphic recording of 2700 measurements (5 min to 1 mos) Absolute or relative display (absolute, deviation, ref, ref %) ­ Monitoring (instantaneous, min, max, avg)
Ranges from 600 mV to 600 Vrms, 800 mV to 800 VDC ­ accuracy for VDC ± 1 % reading +20 D ­50 kHz bandwidth Range from 80  to 32 M - accuracy ± 2 % reading + 10 D ­10 ms quick continuity test Ranges from 5 nF to 5 mF ­ basic accuracy ± 2 % reading + 10 D
Frequency, rotation speed, 3.3 V diode test, temperature measurement (with K-type thermocouple or infrared probe)
Single-phase and balanced three-phase active power values (with or without neutral), simultaneous display of current
2 channels, 31 orders, fundamental frequency from (40 to 450) Hz Total VRMS, THD and selected order (% fundamental, phase, frequency, Vrms)
Up to 100 files in standard .bmp format, viewable on the instrument Isolated optical USB interface SX-Metro PC application software (included)
6 LR6 or (6) AA NiMH batteries ­ Battery life up to 8 h 30 min Universal line adapter isolated from the channels ­ Quick charging in 2 h 30 min Safety according to IEC61010-1 600 V CAT III / EMC according to EN61000-3 & EN61326-1

Consult factory for NIST Calibration prices

100 www.aemc.com

Technical Assistance (800) 343-1391
© Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved.

Vol. 23 Rev.00 02/2023

OSCILLOSCOPES
HANDSCOPE

FUNCTIONAL DISPLAYS
FEATURES
· Two fully isolated channels · Three instruments in one
- 40 MHz Oscilloscope - Double 8000-count TRMS Multimeter / Power Analyzer - Harmonic Analyzer · 3.5 in color LCD screen LED backlighting technology · Integrated interactive multilingual help function · 2 MB recording data · Store graphic recordings of 2700 measurements (5 min to 1 mos) · Communication via isolated USB SCPI protocol

HIGH PERFORMANCE

HARMONIC ANALYZER

Automatically displays measurements for both isolated channels from your
choice of 19 measurement types
TWO INDEPENDENT 8000-COUNT TRMS DIGITAL MULTIMETERS

Measures two channels of individual harmonic content up to the 31st harmonic
STORAGE COMMUNICATION & PC SOFTWARE

PRODUCT INCLUDES
2150.21
Meter, small classic tool bag, US wall plug, USB cable, set of (2) 10 ft color-coded (red/black) leads, set of (2) color-coded (red/black) alligator clips, set of (2) color-coded (red/black) probes, BNC adapter, (2) probes 10:1 600 V BNC male, (6) 1.2 V NiMH rechargeable batteries, printed quick start guide, and a USB drive with software and user manual.
2150.22
Meter, field case, US wall plug, USB cable, set of (2) 10 ft color-coded (red/black) leads, set of (2) color-coded (red/black) alligator clips, set of (2) color-coded (red/black) probes, BNC adapter, (1) probe 10:1 600 V BNC male, (1) AC current probe Model MN251T, MiniFlex® Sensor 3000-24-1-1, (6) 1.2 V NiMH rechargeable batteries, printed quick start guide, and a USB drive with software and user manual.

View real-time measurements on your PC, configure the Handscope, export data to spreadsheet using the SX-Metro included software
Instantly displays measurements in multimeter mode at the press of a button
2150.23 Meter, field case, US wall plug, USB cable, set of (2) 10 ft color-coded (red/black) leads, set of (2) color-coded (red/black) alligator clips, set of (2) color-coded (red/black) probes, BNC adapter, (1) probe 10:1 600 V BNC male, (1) AC current probe Model MN379T, MiniFlex® Sensor 3000-24-1-1, (6) 1.2 V NiMH rechargeable batteries, printed quick start guide, and a USB drive with software and user manual.

SHOWN: CATALOG #2150.22

CATALOG NO. 2150.21 2150.22 2150.23

DESCRIPTION Handheld Portable Oscilloscope Model OX 5042B Handheld Portable Oscilloscope Model OX 5042B w / MN251T & MF 3000-24-1-1 (BNC Output) Handheld Portable Oscilloscope Model OX 5042B w / MN379T & MF 3000-24-1-1 (BNC Output; Low AC current measurement)

Vol. 23 Rev.00 02/2023

Technical Assistance (800) 343-1391
© Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved.

www.aemc.com 101

OSCILLOSCOPES
CURRENT PROBES

MODELS MN251T & MN379T

SPECIFICATIONS
ELECTRICAL Nominal Range Measurement Range
Accuracy
Phase Shift Overload Frequency Range Limit Operating Conditions Working/Common Mode Voltage Output Termination
Output Signal
MECHANICAL Operating Temperature Storage Temperature Operating Relative Humidity Jaw Opening Maximum Conductor Size Dimensions Weight Polycarbonate Material SAFETY Safety Rating

MN251T

MN379T

200 A

5 A / 100 A

(0.5 to 240) A

(0.005 to 6) A; (0.1 to 120) A

3 % of Reading @ 5 A; 1 % of Reading @ 200 A

1 % of Reading @ 5 A; 1 % of Reading @ 100 A

 2.5 ° @ 20 A /  2.5 ° @ 100 A

 4 ° @ 5 A /  2.2 @ 100 A

240 A for 10 min ON, 30 min OFF

(40 to 10) kHz

200 A permanently to 1 kHz; Derating above 3 kHz: 200 A x (1/0.333 F), F in kHz

600 Vrms

10 ft (~3 m) BNC Lead

1 mV/AAC (200 mV @ 200 A)

200 mV/AAC (1 V @ 5 A) & 10 mV/AAC (1 V @ 100 A)

(14 to 131) °F (-10 to 55) °C (-40 to 158) °F (-40 to 70) °C (10 to 35) °C (50 to 95) °F 85 % RH (without roll-off above 35 °C (95 °F))
0.83 in (21 mm) 0.78 in (20 mm) (5.47 x 2.00 x 1.18) in (139 x 51 x 30) mm 6.5 oz (184 g) Polycarbonate with fiberglass charge, UL94 V0

EN 61010-2-32

Consult factory for NIST Calibration prices

MINIFLEX® 3000-24-1-1

SPECIFICATIONS

3000-24-1-1

ELECTRICAL

Range

(5 to 3000) A

Signal Output

1 mV/A

Frequency Range

10 Hz to 20 kHz with current derating

Influence Of Conductor Positioning

1.5 % typical, 3 % max

Influence Of Conductor Positioning In Sensor Against Handle

4 % typical, 6 % max

External Conductor Influence

(35 to 40) dB on contact

Power Supply

9 V Alkaline battery (included)

MECHANICAL

Sensor Diameter

Ø 0.2 (5 mm)

Sensor Length

14 in (~355 mm)

24 in (~609 mm)

Max Conductor Size

3.93 in (~100 mm)

7.6 in (~190 mm)

Connection Cable Length

10 ft (~3.04 M)

Drop Test

Per IEC 68-2-32

Vibration

Per IEC 68-2-6

Mechanical Shock

Per IEC 68-2-27

Weatherproofing

IP50

ENVIRONMENTAL

Operating Temperature Range

(14 to 131) °F (-10 to 55) °C

Storage Temperature Range

(-40 to 158) °F (-40 to 70) °C

Altitude

Operating: (0 to 6560) ft (2000 m), working voltage derating above; Non-operating: (0 to 39,370) ft (12,000 m)

SAFETY

Safety Rating

EN 61010, 1000 V CAT III; 600 V CAT IV

Consult factory for NIST Calibration prices

CATALOG #2132.59 Range (0.05 to 240) A
CATALOG #2153.02 Range (0.005 to 120) A
FEATURES
· Small, compact size · True RMS measurements · Large jaw opening accommodates
conductor sizes up to 250 MCM · 10 foot leads make measurements
in hard to reach areas possible · 40 Hz to 10 kHz response
SAFETY
R ATIN G
3000-24-1-1 only
CATALOG #2132.63 (24 IN)
FEATURES
· True RMS Measurements · 24 in (~60 cm) sensor optional · 10 ft (~3 m) leads makes measure-
ment in hard to reach areas possible · Measurement range of
(0.5 to 3000) Arms · Accuracy ± 1 % of Reading ± 0.25 A · No core saturation or damage if
measured circuit is overloaded · 20 kHz frequency response · Low phase shift for power
measurements · Insensitive to DC: measures only the
AC component on DC+AC signals · Excellent linearity · 9 V Alkaline battery typically offers
150 h of continuous operation

102 www.aemc.com

Technical Assistance (800) 343-1391
© Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved.

Vol. 23 Rev.00 02/2023

OSCILLOSCOPES
OX 9000 SERIES

MODELS OX 9062, OX 9102, OX 9104 & OX 9304 Ergonomic, hand-held oscilloscope with 100 MHz bandwidth and 4 models: oscilloscope, multimeter, analyzer and recorder
OSCILLOSCOPE

OX 9104

HARMONICS

FEATURES
· Wider bandwidth up to 300 MHz (model dependent)
· Advanced triggering and recording options · Increased storage capacity, and more! · 12-bit resolution · 2.5 Gs/s

OX 9062

MULTIMETER - DISPLAYS UP TO 4 CHANNELS SIMULTANEOUSLY

PRODUCT INCLUDES
Scope in carrying case with shoulder strap, set of (2) 5 ft color-coded leads, alligator clips and test probes (4 mm diameter), 10 ft USB cable, µSD memory card, 1-PROBIX Banana Plug (4 mm) adapter, (1) stylus pen, LI-ION 5.8 A·h battery pack, PA40W-2 power adapter with 110 V power cord. Additional accessories (model dependent).

MEASUREMENT BETWEEN H AND V CURSORS: T1, T2, DT, 1/DT, V1, V2, DV, PH

ACCESSORIES/REPLACEMENTS
5000.17 Set of 5 stylus pens

CATALOG NO. 2150.31 2150.32 2150.33 2150.34

DESCRIPTION Handheld Portable Oscilloscope Model OX 9062 IV 60 MHz (2-Channel, 60 MHz) -- SPECIAL ORDER ONLY Handheld Portable Oscilloscope Model OX 9102 IV 100 MHz (2-Channel, 100 MHz) -- SPECIAL ORDER ONLY Handheld Portable Oscilloscope Model OX 9104 IV 100 MHz (4-Channel, 100 MHz) Handheld Portable Oscilloscope Model OX 9304 IV 300 MHz (4-Channel, 300 MHz)

Vol. 23 Rev.00 02/2023

Technical Assistance (800) 343-1391
© Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved.

www.aemc.com 103

OSCILLOSCOPES
OX 9000 SERIES
ERGONOMICS Designed to simplify use with one button access to most functions
In a housing tailor-made to be as compact as possible, the mechanical design makes it possible to integrate the hardware components in a small size with the keypad benefits from new technology developed in the automotive industry.
ISOLATED CHANNELS
Each channel is isolated from each other and from ground (earth) rated at 600 V CAT III.
CHANNEL AND PARAMETER IDENTIFICATION
Each channel and related parameters are identified with identical color against a black background for simpler, quicker viewing. EASY ACCESS VIA TOUCH SCREEN
Intuitive icons are provided to facilitate their use, even with gloves on. ADJUSTABLE STRAP
This helps to optimize operation of the oscilloscope in your hand or on your shoulder when working in the field.
A stand is also available to vary the orientation of the oscilloscope when it is placed on a bench. The oscilloscope can be safely left unattended using the Kensington locking system.
NEW KEYPAD DESIGN FOR OPTIMUM USER COMFORT
Configuration and measurement displays are simple to access from the front panel in one of these 5 specific areas: Utilities (brightness, full screen, screenshot), Measurements, Vertical, Horizontal, Trigger.
LINE POWER AND LI-ION BATTERY CHARGING PORT
Port on left side.

IP
54
Rated

Original

ETHERNET

104 www.aemc.com

Technical Assistance (800) 343-1391
© Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved.

Vol. 23 Rev.00 02/2023

OSCILLOSCOPES
OX 9000 SERIES
APPLICATIONS Ideal for electronic and industrial maintenance

IP54
Housing protected against dust and water spray.
7-INCH WVGA WIDE COLOR TFT TOUCH SCREEN
Makes it easy to view and read the measurements clearly. It also provides a screen resolution of (800 x 480) dpi with manual or automatic brightness.
TOUCH-SCREEN STYLUS STORAGE
Among the essential tools available, the stylus is equipped with a hook for the addition of a cord to make it captive, as required. One end is slightly flattened to prevent rolling when placed on a table or bench.
AUTOSET BUTTON
Quickly and effortlessly adjusts the horizontal and vertical; sensitivity and scales to provide the best resolution.
DIRECT SETTING AND SETUP BUTTONS
COMMUNICATION INTERFACES
These are isolated from one another and from the measurement channels. A dedicated compartment on the right side protected by a flexible cover contains all the different communication interface ports:
" USB host for communication with a PC " Wired RJ45 or WiFi for communication with a PC or
printing via a network printer
" µSD card for data storage with quick transfer and for
upgrading of the instrument's firmware
DIRECT ACCESS ZOOM BUTTON
Activates/deactivates the horizontal Zoom function

ELECTRONIC MAINTENANCE
The OX 9304 model is ideal for electronics with its 300 MHz bandwidth, (4) 600 V CAT III isolated channels, advanced trigger functions, integrated FFT function, complex mathematical calculations on the curves, automatic measurements on 4 channels and the built-in WEB server.
INDUSTRIAL MAINTENANCE
The OX 9304's large 7-inch screen, 300 MHz bandwidth, (4) 600 V CAT III isolated channels and Harmonic Analyzer and Multimeter modes make it ideal for industrial maintenance applications.

Vol. 23 Rev.00 02/2023

Technical Assistance (800) 343-1391
© Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved.

www.aemc.com 105

OSCILLOSCOPES
OX 9000 SERIES

TECHNICAL SPECIFICATIONS

OX 9062

OX 9102

OX 9104

OX 9304

HUMAN-MACHINE INTERFACE

Type of Display

7 in WVGA color TFT LCD touch screen, (800 x 480) dpi ­ LED backlighting (adjustable standby mode)

Different Display Mode

2,500 real acquisition points on screen - vectors with interpolation

Display of Curves on Screen

4 curves + 4 references ­ split screen & full screen modes

Screen Commands

Touch screen ­ icons and graphical commands ­ customizable channel colors

Choice of Language

15 complete languages, menus and online help

OSCILLOSCOPE MODE

Vertical Deflection

Bandwidth

60 MHz

100 MHz

100 MHz

15 MHz, 1.5 MHz or 5 kHz bandwidth limiter

300 MHz

Number of Channels

2 isolated channels

4 isolated channels

Input Impedance

1 M ± 0.5 %, approx. 12 pF

Maximum Input Voltage

600 V CAT III (1,000 V per Probix) ­ from (50 to 400) Hz ­ Probix safety connectors

Vertical Sensitivity

16 ranges from 2.5 mV to 200 V/div and up to 156 µV/div in vertical zoom mode (12-bit converter) ­ Accuracy ± 2 %

Vertical Zoom

'One click Winzoom' mode (12-bit converter and direct graphical zoom on screen) ­ x 16 max.

Probe Factor (non-Probix)

1 / 10 / 100 / 1,000 or any scaling ­ definition of measurement unit

Horizontal Deflection

Sweep Speed

35 ranges from 1 ns/div to 200 s/div., accuracy ± [50 ppm + 500 ps] ­ Roll mode from 100 ms to 200 s/div

Horizontal Zoom

'One click Winzoom' system (direct graphical zoom on screen) x 1 to x 5 or x 100 ­ storage 100 kpts/channel

Triggering

Mode

On all the channels: automatic, triggered, one-shot, auto level 50 %

Type

Edge, pulse width (16 ns-20 s), Delay (48 ns to 20 s), Counting (3 to 16,384) events. Continuous adjustment of trigger position.

Coupling

AC, DC GND, HFR, LFR, noise ­ Level and Hold-off adjustable from 64 ns to 15 s

Sensitivity

 1.2 division p-p up to 300 MHz

Digital Storage

Maximum Sampling Rate

2.5 Gs/s in one-shot mode on each channel (100 Gs/s max. in ETS mode)

Vertical Resolution

12 bits (vertical resolution 0.025 %)

Memory Depth
User Storage / File Management
GLITCH Mode

100 kpts per channel and file viewer in the manager Internal = 1 GB to store the files: trace, text, configuration, math functions, system memory / PDF print files,
PNG image files + high-capacity removable µSD card: SD 2 GB, SDHC (4 to 32) GB and SDXC > 32 GB Duration  2 ns ­ 500,000 min/max pairs

Display Modes

Envelope, vector, accumulation-, averaging (factors 2 to 64) ­ XY (vector) and Y(f) = FFT

Other Functions

AUTOSET

Complete in under 5 s, with recognition of the channels ­ Frequency > 30 Hz

FFT Analyzer & MATH Functions

2,500-point FFT (Lin or Log) with measurement cursors ­ Functions +, -, x / and mathematical function editor

Cursors

2 or 3 cursors: simultaneous V and T with AUTO measurement: T1, T2, Dt, 1/Dt, dBV, Ph

Automatic Measurements

Simultaneously with waveform, 20 automatic measurements per channel and on the 4 channels simultaneously with scroll

MULTIMETER MODE

General Specifications

2 or 4 channels ­ 8,000 cts min/max/frequency/relative ­ TRMS ­ Time/date-stamped graphical recording in logger mode

AC, DC and AC + DC Voltages

600 mV to 600 VRMS, 800 mV to 800 VDC ­ VDC accuracy +/- (0.5 % + 25 D) ­ 200 kHz bandwidth

Resistance

80  to 32 M ­ accuracy 0.5 %R+ 25 D ­ quick continuity test < 10 ms

Other Measurements

Temperature (HX0035 = KTC, HX0036 = Pt100) / Capacitance 5 nF to 5 mF / Frequency 200 kHz / Diode test 3.3 V

Single and Three-Phase Power

Active, Reactive and Apparent power values plus Power Factor simultaneously with the U & I measurements

Harmonic Analyzer Mode

Multi-channel Analysis

2 or 4 (depending on model), 63 orders, fundamental frequency (40 to 450) Hz in auto or manual mode

Simultaneous Measurements

Total Vrms, THD and selected order (% fundamental, phase, frequency, Vrms)

Logger Mode

Acquisition

Duration: 20,000 s ­ Interval: 0.2 s ­ Files: 100,000 measurements

GENERAL

Configuration Memories

Not limited according to device - variable file sizes

Printing

Network printing via Ethernet/Wifi in .png format

PC Communication ­ Software Software
Mains Power Supply Safety / EMC / IP Protection

Ethernet (100 baseT), Wi-Fi-USB (device, 12 Mbps) ­ ScopeNet application software for PC PC: Ethernet and USB, ScopeNet (remote control, data recovery, cursors and automatic measurements)
AndroidTM tablet ­ ScopeAdmin Fleet Administration utility Li-ion rechargeable battery (6,900 mA·h-40 W·h) ­ Battery life of up to 8 h ­ Adjustable standby mode
Adapter / 2-hour fast charger, universal (98 to 264) V / (50/60) Hz) Safety as per IEC 61010-2-30, 600 V CAT III, 1000 V CAT II / EMC as per EN61326-1 / IP54 protection

Mechanical Specifications

(11.52 x 8.29 x 2.60) in (293 x 211 x 66) mm / 4.6 lbs (2.1 kg) with batteries

106 www.aemc.com

Technical Assistance (800) 343-1391
© Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved.

Vol. 23 Rev.00 02/2023

APNOAWLYEZREQRUS,AMLIETTYE/RESN&ERLGOYGGERS

DATA ANALYSIS AND REPORTING SOFTWARE

SEE PAGE 133 FOR MORE INFO ON DATAVIEW® SOFTWARE

CONFIGURE POWER QUALITY / ENERGY ANALYZERS, METERS & LOGGERS
MODELS PEL 52, 102, 103 & 105, POWERPAD® III 8333, 8336, 8436, POWERPAD® IV 8345
Configure functions and parameters from your PC / Customize views, templates and reports / Create and store a complete library of configurations and test options / Display waveforms, trend graphs, harmonic spectrums, text summaries, transients, event logs and stored alarms / Display and print reports of all test results / Retrieve data from the instrument's memory

SEE WEBSITE FOR PRICING AND AVAILABILITY: WWW.AEMC.COM

POWER QUALITY / ENERGY ANALYZERS, METERS & LOGGERS

PowerPad® IV Model 8345 NEW

The PowerPad ® moves up a grade - Class A!
SPECIFICATIONS

A POWERP D IV Class

MODEL ELECTRICAL Inputs Voltage Harmonics Mode Interharmonics Mode Inrush & Transient Capture (number) Shockwaves (Fast transient) Flicker (Pst) Voltage Unbalance (u0,u2)
Trend Recording

8345
5 x voltage / 4 x current, isolated (5 to 1,000) VAC and VDC DC to 63rd order 0 to 62nd order
No maximum (limited by SD card)
Up to 12 kV sampled every 500 ns
< 0.1
(0.5 to 5) % (absolute); ± 0.15 % (absolute)
> 900 parameters 3 d with a sampling period of 200 ms
15 d with a sampling period of 1 s 45 d with a sampling period of 3 s

Sampling Rate
Alarm Mode (types / number) Real-time / Power / Energy / Unbalance Modes Screenshots

Voltage 400 kSps / Current 200 kSps / Surge 2 MSps
52 / 20,000 with Email notifications
Yes / Yes / Yes / Composite
No maximum (limited by SD card)

Power Supply
Carrier Current Detection

Power from phase from (100 to 1000) V AC/DC with external supply block (included)
Yes

Battery Life MECHANICAL

Cartridge Li-ion ­ 5800 A·h battery pack (included)  6 h w/ display ON;  10 h w/ display OFF

Data Storage

16 GB SD-Card (included) for snapshot, transients, alarms and trend recording

Display Clock / GPS Operating Temperature

7 in color LCD touch screen: 800 x 480 (WVGA) Yes, built-in
(32 to 104) °F (0 to 40) °C

Communication

USB, Ethernet, Wi-Fi, Web server, IRD server, USB stick port (Type A)

Dimensions

(7.87 x 11.22 x 2.17) in (200 x 285 x 55) mm

Weight (meter only)

4.19 lb (1.9 kg)

COMPLIANCE & STANDARDS

Safety

IEC 61010 1000 V CAT IV

Environmental

IEC 61557-12 & IEC 62586

Measurement Standard

IEC 61000-4-30 (Ed 3) Class A (Full)

EN50160 Monitoring Mode

With PAT3 software

Warranty

*3 y (registration must be done within 30 d of the date of purchase)

Consult factory for NIST Calibration prices

CATALOG NO. DESCRIPTION

2136.35

PowerPad® IV Model 8345 (no probes)

2136.36

PowerPad® IV Model 8345 w/4 194-24-BK MiniFlex® Sensors

*

UPON REGISTERI

TM ETHERNET

WEB SERVER

IP 54

PRODUCT INCLUDES
CAT. # 2136.35 - POWERPAD IV MODEL 8345 (NO PROBES)
CAT. # 2136.36 - POWERPAD IV MODEL 8345 (WITH (4) MINIFLEX® MA194-24-BK FLEXIBLE CURRENT SENSORS ) Extra large tool bag, internal carrying pouch, hand strap, USB cable, (5) 10 ft black voltage leads with alligator clips, (12) color-coded input ID markers, power adapter (PA32ER) with US power cord, (2) 6 ft stackable leads, (2) 10 ft black voltage leads with alligator clips for power adapter PA32ER, (1) power plug adaptor for PA32ER, 5.8 A·h Li-ion battery pack, quick start guide, and a USB stick with DataView® software and user manual.

(4) MINIFLEX® MA194-24-BK FLEXIBLE CURRENT SENSORS (WITH CAT.# 2136.36)

NG

108 www.aemc.com

Technical Assistance (800) 343-1391
© Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved.

Vol. 23 Rev.00 02/2023

POWER QUALITY/ENERGY ANALYZERS, METERS & LOGGERS
FEATURES

FEATURES

Large Functional Displays

· Full compliance with IEC 61000-4-30 ed. 3.0 Class A functions · Voltage quality diagnostics

ENERGY EVALUATION

TREND

· Real-time display of color waveforms (5 voltage/4 current) from 1 cycle to 10/12 cycles

· Calculation of unbalance (current and voltage)

· Automatic recognition of different current sensors

· Capture shockwaves up to 12 kV with a resoluton of 500 ns

· Trend recording period from 200 ms to 2 h

· RMS and Peak InRush for up to 30 min · Display of phasor diagrams

SHOCKWAVES

ALARMS

· Waveforms at 512 samples per cycle, with Min/Max 2.5 s

· True InRush capabilities to study loads during setup

· Parameterization with software for True RMS single-, twoand three-phase measurements at 512 samples/cycle, plus DC

· Records and stores hundreds of parameters in memory every 10/12 periods

· Measurements and recordings accessible on 7 inch color trouch screen display

TRANSIENTS

CARRIER CURRENT

· True RMS voltage and current measurement

· Measurements on all installation types: three-phase, Aron connection, etc.

· Electrical network monitoring with setting of alarms

· Fast transient events are captured and stored in memory

· Communication options: Webserver, Wi-Fi, Ethernet and USB
· Power W, VA and var (P, N, Q1, S and D) measurements
· Measurement of energy values (total and per phase) with energy valuation

INTERHARMONICS (HARMONIC MODE)

TRUE INRUSH®

· PF, DPF, CF and THD calculations and measurements

· Calculation so Pst & Plt flicker and sliding Pst · Harmonics (amplitude/phase shift) from DC to the 63rd order · Inter-harmonic subgroups from 0 to the 62nd order

· Calculations of K factor & FHL

· 2 carrier current frequencies monitored
ACCESSORIES/REPLACEMENTS
CATALOG #2140.28 AC/DC Current Probe Model MR193-BK CATALOG #2140.32 AC Current Probe Model MN93-BK CATALOG #2140.33 AC Current Probe Model SR193-BK CATALOG #2140.34 AmpFlex® Sensor 24 in Model 193-24-BK CATALOG #2140.35 AmpFlex® Sensor 36 in Model 193-36-BK CATALOG #2140.36 AC Current Probe Model MN193-BK CATALOG #2140.48 MiniFlex® Sensor 10 in Model MA193-10-BK CATALOG #2140.50 MiniFlex® Sensor 14 in Model MA193-14-BK CATALOG #5100.16 Magnetic Hook

Includes FREE DataView® software for configuring, data retrieval, real-time display, analysis and report generation
CATALOG #2133.76 Carrying Bag CATALOG #2140.43 Lead - Set of 5, 10 ft (3M) Black Leads w/5 Black Alligator Clips (Leads rated 600 V CAT IV 10 A, Clips rated 1000 V CAT IV 15 A, UL) CATALOG #2140.44 (1) 10 ft (3 M) Black Lead w/(1) Black Alligator Clip (Lead rated 1000 V CAT IV 15 A, Clip rated 1000 V CAT IV 15 A, UL) CATALOG #2140.46 Cable - Replacement 5 ft USB Cable CATALOG #2140.80 Sensor - MiniFlex® Sensor Model MA194-24-BK CATALOG #2960.47 Battery - Replacement 5.8 A·h 61.9 W·h Li-ion Battery Pack CATALOG #5100.14 Adapter - Replacement Power Plug Adapter for PA32ER CATALOG #5100.15 Adapter - Replacement 1000 V PA32ER Power Supply

Vol. 23 Rev.00 02/2023

Technical Assistance (800) 343-1391
© Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved.

www.aemc.com 109

POWER QUALITY / ENERGY ANALYZERS, METERS & LOGGERS
THREE-PHASE POWER QUALITY ANALYZERS

NG

POWERPAD® III MODELS 8333 & 8336

*

U PON

R EGIST ERI

SD card for trend recordings and data storage,

extensive memory for high snapshot quantity,

captured transients/inrush and alarm events

SPECIFICATIONS

MODELS Input Terminals Inputs Voltage (TRMS AC+DC) Voltage Ratio
Current (TRMS AC+DC)
Frequency (Hz)
Distribution Systems
Power Values Energy Values Harmonics Transients Flicker (Pst/Plt) Unbalance Recording Alarm Mode Peak Phasor Display
Display
Snapshots Languages Communication Interface MECHANICAL Battery Life
Power Supply
Dimensions / Weight SAFETY Safety Rating / IP

8333 4 voltage / 3 current 3 voltage / 3 current

8336 5 voltage / 4 current 4 voltage / 4 current

(2 to 1000) V

up to 500 kV

MN93: 500 mA to 200 AAC; MN193: (0.005 to 100) AAC

SR193 Clamp: (1 to 1000) AAC AmpFlex® or MA193 Clamps: 100 mA to 10000 AAC

MR193 Clamp: (1 to 1000) AAC/1300 ADC

SL261 Clamp: 50 mA to 100 AAC/DC

Current Ratio: up to 60 kA

(40 to 69) Hz

1P 2W, 1P 3W, 2P 2W, 2P 3W, 1P 2W, 1P 3W, 2P 2W,2 P 3W,

2P 4W, 3P 3W, 3P, 4W, 2P 4W, 3P 3W, 3P, 4W and 3P

Split-Phase 2W & 3W

5W, 2 ½ Element

and Aron meters

and Aron meters

W, VA, var, VAD, PF, DPF, cos Ç, tan Ç

Wh, varh, VAh, VADh

1st to 50th, Direction, Sequence; THD: 0 to 50, phase

up to 51

up to 210

Yes/No

Yes/Yes

Yes

Yes

10 types; 4000 recorded 40 types; 16,000 recorded

Yes

Automatic

Color ¼ VGA TFT screen (320 x 240) diagonal

5.82 in (148 mm)

12

50

> 27

USB

 10 h,  15 h in Record mode 9.6 V NiMH rechargeable battery pack (included) External AC supply: (110/230) VAC ±10 % (50/60) Hz (9.8 x 7.8 x 2.6) in (249 x 198 x 66) mm / 4.3 lb (1.95 kg)
IEC 61010, 1000 V CAT III; 600 V CAT IV / IP53

8333

SAFETY

IP

R ATIN G

53

8336

PRODUCT INCLUDES
CAT. # 2136.10 MODEL 8333 (NO PROBES)
Extra large carrying bag, soft carrying pouch, (4) 10 ft black voltage leads with alligator clips, 5 ft USB cable, (12) color-coded input ID markers, 110/240 V power adapter with US power cord, 9.6 V NiMH battery, SD card, printed quick start guide and USB drive with DataView® software and user manual.

CAT. # 2136.30 MODEL 8336 (NO PROBES)
Extra large carrying bag, soft carrying pouch, (5) 10 ft black voltage leads with alligator clips, 5 ft USB cable, (12) color-coded input ID markers, 110/240 V power adapter with US power cord, SD card, 9.6 V NiMH battery, printed quick start guide, and USB drive with DataView® software and user manual.

Consult factory for NIST Calibration prices

KIT OPTIONS

8333 AS ABOVE WITH AMPFLEX®
193 FLEXIBLE CURRENT PROBE OR
(10 kA) CATALOG # 2136.11 24 IN, RATED 600 V CAT IV

AS ABOVE, MN193 CURRENT PROBE (5/100 A) CATALOG # 2136.12 Rated 600 V CAT III

8336
AS ABOVE WITH AMPFLEX®
193 FLEXIBLE CURRENT PROBE OR
(10 kA) CATALOG # 2136.31
24 IN, Rated 600 V CAT IV

AS ABOVE, MN193 CURRENT PROBE (5/100 A) CATALOG # 2136.32 Rated 600 V CAT III

* 3 YEAR WARRANTY ONLY APPLIES WHEN METER IS REGISTERED WITHIN 30 DAYS OF PURCHASE

110 www.aemc.com

Technical Assistance (800) 343-1391
© Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved.

Vol. 23 Rev.00 02/2023

POWER QUALITY/ENERGY ANALYZERS, METERS & LOGGERS
THREE-PHASE POWER QUALITY ANALYZERS

Captures and Records Transients, Events & Waveforms
Simultaneously!

MODELS 8333 & 8336 Large Functional Displays

CONFIGURATION

TRANSIENT MODE

POWER AND ENERGY MODE

PHASOR DIAGRAM

RECORDING MODE

HARMONICS MODE

FEATURES
· True RMS single-, two- and three-phase measurements at 256 samples/cycle, plus DC
· Real-time color waveforms · Easy-to-use on-screen setup · Automatic current probe recognition and scaling · True RMS voltage and current measurement · Measures DC volts, amps and power · Displays and captures voltage, current and power
harmonics to 50th order, including direction, in real-time · Captures transients down to 1/256th of a cycle · Stores comprehensive data base of logged data · Phasor diagram display · kVA, kvar and kW per phase and total · kVAh, kvarh and kWh per phase and total · Neutral current calculated and displayed for three-phase · Transformer Factor K display (8333, 8336) · Power Factor, displacement PF display · Captures up to 210 transients (8336) · Short term (8333) and Long term (8336) flicker display · Phase unbalance (current and voltage) · Harmonic Distortion (total and individual) from 1st to 50th · Alarms, surges and sags · Screen snapshot function captures waveforms or other
information on the display · Includes FREE DataView® software for configuring, data
retrieval, real-time display, analysis and report generation

ACCESSORIES/REPLACEMENTS
CATALOG #2133.73 Extra Large Classic Tool Bag (18 x 9 x 12) in CATALOG #2140.28 AC/DC Current Probe Model MR193-BK CATALOG #2140.32 AC Current Probe Model MN93-BK CATALOG #2140.33 AC Current Probe Model SR193-BK CATALOG #2140.34 AmpFlex® Sensor 24 in Model 193-24-BK CATALOG #2140.35 AmpFlex® Sensor 36 in Model 193-36-BK CATALOG #2140.36 AC Current Probe Model MN193-BK

CATALOG #2140.40 BNC Adapter for AC/DC Current Probe Model SL261 and models for use with 8220, 8333, 8335, 8336, 8435, 8436 & PEL Series CATALOG #2140.44 (1) 10 ft (3 M) Black Lead w/(1) Black Alligator Clip (Lead rated 1000 V CAT IV 15 A, Clip rated 1000 V CAT IV 15 A, UL) CATALOG #2140.48 MiniFlex® Sensor 10 in Model MA193-10-BK CATALOG #2140.50 MiniFlex® Sensor 14 in Model MA193-14-BK CATALOG #2140.80 MiniFlex® Sensor 24 in Model MA194-24-BK CATALOG #2140.77 Phase Power Adapter (8333 & 8336)

CATALOG NO.
2136.10 2136.11 2136.12 2136.30 2136.31 2136.32

DESCRIPTION
PowerPad® III Model 8333 (no probes) PowerPad® III Model 8333 w/3 193-24-BK Sensors PowerPad® III Model 8333 w/3 MN193-BK Probes PowerPad® III Model 8336 (no probes) PowerPad® III Model 8336 w/4 193-24-BK Sensors PowerPad® III Model 8336 w/4 MN193-BK Probes

Vol. 23 Rev.00 02/2023

Technical Assistance (800) 343-1391
© Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved.

www.aemc.com 111

POWER QUALITY / ENERGY ANALYZERS, METERS & LOGGERS
THREE-PHASE POWER QUALITY ANALYZERS

POWERPAD® III MODEL 8436
Supplied with an 8 GB SD card for storing up to 2 GB trend recordings

(4) current and (5) voltage input terminals

SPECIFICATIONS

MODEL ELECTRICAL Sampling Frequency Data Storage
Voltage (TRMS)
Current (TRMS)
Frequency (Hz) Other Measurements Harmonics Power Supply Battery Life MECHANICAL Communication Port Display Dimensions Weight SAFETY Safety Rating

8436
256 samples/cycle SD card for trend recording; Additional separate 12.5 MB partitioned memory for snapshots, transient / Inrush & alarms
Phase-to-Phase: 2000 V Phase-to-Neutral: 1000 V Voltage Ratio: up to 500 kV MN Clamp: (0 to 6) A/120 A or (0 to 240) A SR Clamp: (0 to 1200) A MR Clamp: (0 to 1000) AAC, (0 to 1400) ADC MiniFlex®: (10 to 3000) A AmpFlex®: (10 to 10) kA(1) SL261 Clamp: 50 mA to 100 AAC/DC J93: (50 to 3500) AAC/DC Current Ratio: 10 mA to 60 kA
(40 to 69) Hz kW, kvar, kVA, PF, DPF, kWh, kvarh, kVAh,
Factor K, Flicker 1st to 50th, Direction, Sequence 9.6 V NiMH rechargeable battery pack (included) (110 to 1000) V DC to 400 Hz
 10 h with display on;  15 h with display off (record mode)
Optically isolated USB ¼ VGA (320 x 240) color LCD display with adjustable brightness & contrast (10.6 x 9.8 x 7.1) in (270 x 249 x 180) mm
8.2 lb (3.7 kg) with batteries
EN 61010, 600 V CAT IV(2), 1000 V CAT III

(1) Crest factor at 6500=1

Consult factory for NIST Calibration prices

(2) When used with SR193 or AmpFlex® probes

600 V CAT III with MN193 or MR193 probes

PRODUCT INCLUDES
8436 KIT CATALOG #2136.44 Extra large tool bag, accessory pouch, 5 ft USB cable, (5) 10 ft black voltage leads with alligator clips, 110 V US power cord, line power cord 110-1000 V DC to 400 Hz, (12) color-coded input ID markers, (4) water-tight AmpFlex® 196A-24-BK sensors (2136.44 only), 9.6 V NiMH battery, SD card, printed quick start guide, high-voltage warning card, and a USB drive with DataView® software and user manual.

*

UPON REGISTERI

SAFETY

cover closed

R ATIN G

FEATURES

· Measurement of TRMS voltages up to 1000 Vrms AC/DC for two-, three-, four- or five-wire systems

· Measurement of TRMS currents up to 10,000 Arms (sensor dependent)

· 65 µs sample rate

· Direct measurement of neutral current and voltage

· Record and display trend data as fast as once per second for one month for up to 25 variables

· Transient detection on all V and I inputs (up to 210)

· Selectable PT and CT ratios

· Inrush current measurement

· Calculation of Crest Factors for V and A

· Calculation of Factor K for transformers

· Calculation of short and long term flicker and three-phase voltage unbalance

· Measures harmonics (referenced to the fundamental or RMS value) for voltage, current or power, up to 50th harmonic

· Displays of harmonic sequencing and direction and calculation of overall harmonics

· Real-time display of phasor diagrams including values and phase angles

· Measurement of active, reactive and apparent power per phase and their respective sum total

· Calculation of power factor, displacement power factor and tangent factor

· Recording, time stamping and characterization of disturbance (swells, sags and interruptions, exceedance of power and harmonic thresholds)

· 2 GB Trend Recording memory; Alarm, Snapshot and Transient/Inrush memories are separate

· Measurement of energy kVAh, kvarh & kWh

· The Max and Min RMS measurements are calculated every half-period

· Includes DataView® software for configuring, real-time display, analysis and report generation

NG

* 3 YEAR WARRANTY ONLY APPLIES WHEN METER IS REGISTERED WITHIN 30 DAYS OF PURCHASE

112 www.aemc.com

Technical Assistance (800) 343-1391
© Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved.

Vol. 23 Rev.00 02/2023

POWER QUALITY/ENERGY ANALYZERS, METERS & LOGGERS
THREE-PHASE POWER QUALITY ANALYZERS

MODEL 8436 Large Color Functional Displays
INSTALLATION OF THE LEADS AND CURRENT SENSORS Color-coded ID markers are supplied with the PowerPad® III to identify the leads and input terminals.

CONFIGURATION

TRANSIENT MODE

The voltage and current inputs, as well as the power cord connection are constructed with screw on, watertight connectors rated to IP67.

INRUSH PEAK

PHASOR DIAGRAM

LEAD & ALLIGATOR CLIP POWER CORD

Catalog #2140.73

Catalog #5000.63

TREND ANALYSIS

HARMONICS MODE

AMPFLEX® SENSORS
Catalog #2140.75 (Included with
Cat. #2136.44 only)

LINE POWER ADAPTER Catalog #5000.89

POLE MOUNTING KIT Catalog #2137.82 Set of (2) with hardware

ACCESSORIES/REPLACEMENTS
CATALOG #2133.73 Extra Large Classic Tool Bag (18 x 9 x 12) in CATALOG #2137.82 Pole Mounting Kit CATALOG #2140.19 Replacement - 9.6 V NiMH Rechargeable Battery CATALOG #2140.45 Set of (12) color-coded Input ID Markers CATALOG #2140.73 (1) 10 ft (3 M) Black Lead (Waterproof cap) (Rated 1000 V CAT IV) and (1) Black Alligator Clip (Rated 1000 V CAT IV, 15 A, UL)

CATALOG #2140.75 AmpFlex® Sensor 24 in Model 196A-24-BK (waterproof - IP67) CATALOG #2140.79 MiniFlex® Sensor 14 in Model MA196-14-BK (waterproof - IP67) CATALOG #5000.43 Probe - Set of (2) Color-coded (Red/Black) Magnetize Voltage Probes (Rated 600 V CAT IV, 1000 V CAT III) CATALOG #5000.63 Power Cord 110 V for use only with Models 8435 and 8436 CATALOG #5000.77 Cable Reeling Box CATALOG #5000.89 Line Power Adapter 110-1000 V DC to 400 Hz (Replacement - for use only with Model 8436)

CATALOG NO. DESCRIPTION

2136.43

PowerPad® III Model 8436 (No Sensors - Waterproof IP67)

2136.44

PowerPad® III Model 8436 w/4 196A-24-BK (AmpFlex®- Waterproof IP67 )

Vol. 23 Rev.00 02/2023

Technical Assistance (800) 343-1391
© Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved.

www.aemc.com 113

POWER QUALITY / ENERGY ANALYZERS, METERS & LOGGERS
POWER & ENERGY LOGGER PEL 52
MODEL PEL 52 Time/date stamped electrical measuring instrument to understand and improve electrical consumption

NEW

SPECIFICATIONS

Coming Later this Year!

MODEL

PEL 52

GENERAL

Inputs

2V / 2I

Types of installations

Single phase, split phase or 2 single-phase channels

Recording / Data Storage Rate Unlimited duration (4 GB max recording size) / 1 s to 1 h (Min/Avg/Max)

Network Frequency

(45 to 65) Hz

Voltage

(10 to 600) V

ELECTRICAL

VOLTAGE

RANGE

RESOLUTION

ACCURACY

Vrms

(10 to 660) V P to N

0.1 V

± 0.2 % Reading ± 0.2 V

Urms

(20 to 1200) V P to P

0.1 V

± 0.2 % Reading ± 0.4 V

CURRENT MEASUREMENT @ (50 and 60) HZ
Amps (1 V nominal) (excluding clamp accuracy)

RANGE

RESOLUTION

Probe dependent

Probe

(0.2 % < I < 120 % Inom) dependent

ACCURACY
± 0.2 % Reading ± 0.02 Inom

WEB SERVER
TM

POWER

RANGE

RESOLUTION

ACCURACY

Watts P-Q-S (W-var-VA)
Power Factor

V = (100 to 660) V I = (5 to 120) % Inom

Probe dependent

± 0.3 % R ± 0.003 % Pnom ± 1 % R ± 0.01 % Qnom
± 0.3 % R ± 0.003 % Snom

Pending

IP 54

-1 to 1

0.001

±0.02 %

Cos Ç (DPF) ENERGY

-1 to 1 RANGE

0.001 RESOLUTION

±0.05 % ACCURACY

Ep-Eq-Es (Wh, varh, VAh)

V = (100 to 660) V I = (5 to 120) % Inom

0.001 and ±0.02%

±0.5 % Reading ±2.5 % Reading ±0.5 % Reading

MECHANICAL Communication

Wi-Fi (access point and hot spot)

PRODUCT INCLUDES

Data Storage Dimension Weight Case Display Type Real-Time Clock Power Supply Battery Life ENVIRONMENTAL Operating Temperature / Relative Humidity Storage Temperature SAFETY Electro-MagneticCompatibility (EMC) Safety Rating / CE Rating IP Rating

8 GB SD-Card (included); expandable to 32 GB (7.08 x 3.46 x 1.45) in (180 x 88 x 37) mm 14.10 oz (400 g)
Compact and rugged, shock and vibration IEC 61010 LCD with blue backlight
Time and date stamp for Trend mode From phase 1 (90 to 660) V battery backup when power OFF
3 h without Wi-Fi, 1 h typical with Wi-Fi enabled
(-4 to 122) °F (-20 to 50) °C / (10 to 85) % RH (-40° to 158) °F (-40 to 70) °C / (0 to 95) % RH w/out battery
EN 61326-1 for emission and immunity IEC/EN 61010-2-30 (600 V CAT III) / Yes
IP54 per IEC 60529

CATALOG #2137.69 (WITH PROBES) Soft carrying bag, (2) MiniFlex® MA19310-BK sensors, (3) black test leads and alligator clips, 110 V US power Cord, (1) adapter for power cord, 8 GB SD card, USB SD card reader, (2) AAA rechargeable batteries, quick start guide, and USB drive with DataView® software and user manual.
CATALOG #2137.71 (NO PROBES) Soft carrying bag, (3) black test leads and alligator clips, 110 V US power Cord, (1) adapter for power cord, 8 GB SD card, USB SD card reader, (2) AAA rechargeable batteries, quick start guide, and USB drive with DataView® software and user manual.

* Minimum and maximum values are current probe dependent. Consult factory for NIST Calibration prices

CATALOG NO. 2137.69 2137.71

DESCRIPTION Power & Energy Logger Model PEL 52 (w/LCD, w/2 MA193-10-BK sensors) Power & Energy Logger Model PEL 52 (w/LCD, no sensors)

114 www.aemc.com

Technical Assistance (800) 343-1391
© Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved.

Vol. 23 Rev.00 02/2023

POWER QUALITY/ENERGY ANALYZERS, METERS & LOGGERS

FEATURES
· Low cost, simple-to-use, portable, single- and dual- (splitphase) power & energy data logger
· Wide backlit LCD display
· Install without cutting off the electrical network being monitored
· Vital energy data is easily measured, recorded and analyzed
· TRMS voltage and current measurement up to 600 V
· Powered via the measuring phase
· Measurement of the AC phase currents (I1, I2) (dependent on sensor)
· RMS AC measurements (50 Hz and 60 Hz), aggregation every second without missing measurements
· Easy to use, automatic recognition of current sensors
· W, VA and var (P, Q, S, N and D) power measurements · Calculation of the Cos Ç and Power Factor (DPF) · Aggregation measurements over a period from 1 minute to 1 hour
· Storage of the 1 s and aggregated measurements on SD/SDHC card; data can be read directly on a PC
· Remote connectivity via IRD server
· Integrated web server for for remote viewing (AndroidTM, iOS, Windows, etc.)
· Wi-Fi offers accessibility to diagnose problems in real-time and/ or multi-station operation.
· Data saved on SD card for easier transport · Includes FREE DataView® software for configuring, data
retrieval, real-time measurement display, data analysis and report generation
· Compact casing with built-in magnets to facilitate mounting for easier implementation in electrical cabinets 2-year warranty
· ECO-DESIGN - environmental aspects considered during product development to make the lowest possible environmental impact throughout the product life cycle

Large Functional Displays

INFORMATION MODE

MEASUREMENT MODE (2P-3W2I)

Hook up, Wi-Fi, aggregation period, Real-time updates are displayed for

can be configured from the front voltage (V), current A) active power (P),

panel of the PEL 52.

reactive power (Q), apparent power (S),

Current ratios and number of turns frequency (Hz), power factor (PF).

need to be configured via the PEL

Transer software based on the

current sensor type.

MAX MODE (1P-2W1I)

ENERGY MODE

Max aggregated values of measurements and energy.

Active energy (Wh), reactive energy (varh), apparent energy (VAh). The energies displayed are the total energies, of the source or of the load. (The "h" symbol is not displayed on the screen. You will see W, VA, var for Wh, VAh and varh. Downloaded recordings will show the "h")

ACCESSORIES/REPLACEMENTS

APPLICATIONS
· Load surveys - Find out how much energy each item of equipment consumes operating at its min/max power level.
· Energy analysis - Estimate energy consumption before and after the improvements.
· Energy surveys - The measurements for energy surveys must be performed at several locations on the evaluation site. Starting with the main power, compare the power and energy measurements on the electricity meter and bills. Sub metering can then be performed on downstream of the installation.

CATALOG #2140.32 AC Current Probe Model MN93-BK CATALOG #2140.33 AC Current Probe Model SR193-BK CATALOG #2140.34 AmpFlex® Sensor 24 in Model 193-24-BK CATALOG #2140.35 AmpFlex® Sensor 36 in Model 193-36-BK CATALOG #2140.36 AC Current Probe Model MN193-BK CATALOG #2140.48 MiniFlex® Sensor 10 in Model MA193-10-BK CATALOG #2140.50 MiniFlex® Sensor 14 in Model MA193-14-BK CATALOG #2140.80 MiniFlex® Sensor 24 in Model MA194-24-BK CATALOG #2140.44 (1) 10 ft (3 M) Black Lead w/(1) Black Alligator Clip (Lead rated 1000 V CAT IV 15 A, Clip rated 1000 V CAT IV 15 A, UL) CATALOG #2140.45 Set of (12), color-coded Input ID Markers CATALOG #5000.43 Magnetized Voltage Probe Set of (2) color-coded (Red/Black) magnetized voltage probes (Rated 600 V CAT IV, 1000 V CAT III)

Vol. 23 Rev.00 02/2023

Technical Assistance (800) 343-1391
© Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved.

www.aemc.com 115

POWER QUALITY / ENERGY ANALYZERS, METERS & LOGGERS
POWER & ENERGY LOGGERS PEL 100 SERIES

MODEL PEL 102 Monitor your energy usage and costs locally or from anywhere in the world!
FEATURES
· Simple-to-use, single-, dual- (split-phase) and three-phase (Y, ) power & energy loggers
· Designed to work in 1000 V CAT III and 600 V CAT IV environments and fits in many distribution panels
· Power measurements: kVA, kW and kvar
· Energy measurements: kVAh, kWh (source, load) and kvarh (quadrant indication)
· Updated features in DataView® software for configuring real-time communication with a PC and report generation with pre-defined or user defined templates
· 8 GB SD card supplied, can be upgraded up to 32 GB
· USB, LAN, Ethernet and Bluetooth (Class 1 wireless communication, up to 300 ft away)
· Satisfies the monitoring requirements of NEC Code 220.87
· Power adapter allows the PEL 102 to be powered from a phase measurement input
· Provides all the necessary functions for power and energy data logging for 50 Hz, 60 Hz, 400 Hz and DC distribution systems
· Automatic recognition of the connected current sensors/probes
· Magnetic case ­ can be mounted inside power panels
PRODUCT INCLUDES
PEL 102 KIT CATALOG #2137.51 (SHOWN) Small classic tool bag, (3) MiniFlex® MA193-10-BK sensors, 5 ft USB cable, (4) black test leads and alligator clips, 5 ft 115 V power cord, (12) colorcoded ID markers, safety and compliance sheets, 8 GB SD card with USB-SD card reader, printed quick start guide, and USB drive with DataView® software and user manual.

TM ETHERNET

SAFETY R ATIN G

* IP 54

ACCESSORIES
CATALOG #2137.98 Adapter - 600 V CAT III Power Adapter for use with Models PEL 102 & PEL 103 *ADAPTER SOLD SEPARATELY
SEE PAGE 120 & 121 FOR MORE OPTIONAL ACCESSORIES

Phase Powered

ANDROIDTM APP AVAILABLE
FOR PEL 102, 103 & 105!
· Configure measurements and recordings
· Display data in real-time
· For use on devices with an AndroidTM platform
· NEW software sensors providing all comprehensive and instantaneous motors electrical parameters such as rotation speed, efficiency and torque

CATALOG NO. 2137.51 2137.61

DESCRIPTION Power & Energy Logger Model PEL 102 (No LCD, w/3 MA193-10-BK Sensors) Power & Energy Logger Model PEL 102 (No LCD, No Sensors)

116 www.aemc.com

Technical Assistance (800) 343-1391
© Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved.

Vol. 23 Rev.00 02/2023

POWER QUALITY/ENERGY ANALYZERS, METERS & LOGGERS
POWER & ENERGY LOGGERS PEL 100 SERIES

MODEL PEL 103 Large Functional Displays

INFORMATION MODE

MEASUREMENT MODE

Hook up, voltage and current ratios and aggregation period can be configured

Real-time updates are displayed for voltage, current, power, frequency,

TM ETHERNET

from the front panel of the PEL 103

power factor and tangent

SAFETY

*

MAX MODE

HARMONIC MODE

R ATIN G

IP 54

FEATURES

Max values for voltage, current (including Total Harmonic Distortion (THD) can be neutral current), power and harmonics displayed by phase or phase to phase.
Neutral current THD can also be displayed.
PRODUCT INCLUDES
PEL 103 KIT (W/LCD) CATALOG #2137.52 (SHOWN) Small classic tool bag, (3) MiniFlex® MA193-10-BK sensors, 5 ft USB cable, (4) black test leads and alligator clips, power cord, (12) color-coded ID markers, safety data sheet, compliance sheet, 8 GB SD card with USB-SD card reader, printed quick start user guide, and USB drive with DataView® software and user manual.

ACCESSORIES
CATALOG #2137.98 Adapter - 600 V CAT III Power Adapter for use with Models PEL 102 & PEL 103 *ADAPTER SOLD SEPARATELY
SEE PAGES 120 & 121 FOR MORE OPTIONAL ACCESSORIES

Phase Powered

· Simple-to-use, single-, dual- (split-phase) and three-phase (Y, ) power & energy loggers
· Designed to work in 1000 V CAT III and 600 V CAT IV environments and fits in many distribution panels
· Power measurements: kVA, kW and kvar
· Energy measurements: kVAh, kWh (source, load) and kvarh (quadrant indication)
· Updated features in DataView® software for configuring real-time communication with a PC and report generation with pre-defined or user defined templates
· 8 GB SD card supplied, can be upgraded up to 32 GB
· USB, LAN, Ethernet and Bluetooth (Class 1 wireless communication, up to 300 ft away)
· Satisfies the monitoring requirements of NEC Code 220.87
· PEL 103 can be configured from front panel, DataView® control panel or the FREE AndroidTM application
· Provides all the necessary functions for power and energy data logging for 50 Hz, 60 Hz, 400 Hz and DC distribution systems
· Automatic recognition of the connected current sensors and probes
· Magnetic case ­ can be mounted inside power panel
· Supports 17 network configurations

CATALOG NO. 2137.52 2137.62

DESCRIPTION Power & Energy Logger Model PEL 103 (w/LCD, w/3 MA193-10-BK Sensors) Power & Energy Logger Model PEL 103 (w/LCD, No Sensors)

Vol. 23 Rev.00 02/2023

Technical Assistance (800) 343-1391
© Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved.

www.aemc.com 117

POWER QUALITY / ENERGY ANALYZERS, METERS & LOGGERS
POWER & ENERGY LOGGERS PEL 100 SERIES

MODEL PEL 105 Three-Phase Power and Energy Logger Watertight...great for outdoor use!
FEATURES
· Simple-to-use, single-, dual- (split-phase) and three-phase (Y, ) power & energy loggers
· Designed to work in 1000 V CAT III and 600 V CAT IV environments
· Supports 17 different network connections · Power measurements: kVA, kW and kvar · Energy measurements: kVAh, kWh (source, load) and
kvarh (four quadrant indication) · Includes DataView® software for configuring, real-time
display, analysis and report generation · 8 GB SD card supplied, can be upgraded up to 32 GB · USB, LAN, Ethernet, Wi-Fi and Bluetooth communication
(Class 1 wireless communication, up to 300 ft away) · Satisfies the monitoring requirements of NEC Code 220.87 · PEL 105 can be configured from front panel, DataView®
control panel or the FREE AndroidTM application · Provides all the necessary functions for power and
energy data logging for 50 Hz, 60 Hz, 400 Hz and DC distribution systems · Automatic recognition of the connected current sensors and probes · Powers directly from phase input · Pole mountable
ACCESSORIES
POLE MOUNTING KIT CATALOG # 2137.82 Set of (2) with hardware
SEE PAGES 120 & 121 FOR MORE OPTIONAL ACCESSORIES

IP 54 cover open cover closed
TM

ETHERNET
Phase Powered

PRODUCT INCLUDES
PEL 105 KIT CATALOG #2137.59 (SHOWN) Large classic tool bag, accessory pouch, (5) 10 ft black voltage leads (watertight cap) with alligator clips, (4) water-tight AmpFlex® 196A-24-BK sensors (Cat.# 2137.59 only), (12) color-coded input ID markers, 5 ft USB cable, power adapter 110 V/240 V with US power cord, 9.6 V NiMH battery, 8 GB SD card, USB SD card reader, printed quick start guide, high-voltage waning card, and a USB drive with DataView® software and user manual.

CATALOG NO. 2137.57 2137.59

DESCRIPTION Power & Energy Logger Model PEL 105 (No sensors, Waterproof IP67, DataView® Software) Power & Energy Logger Model PEL 105 w/4 196A-24-BK (Waterproof IP67, DataView® Software)

118 www.aemc.com

Technical Assistance (800) 343-1391
© Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved.

Vol. 23 Rev.00 02/2023

POWER QUALITY/ENERGY ANALYZERS, METERS & LOGGERS
POWER & ENERGY LOGGERS PEL 100 SERIES

SPECIFICATIONS

MODELS

PEL 102, PEL 103 & PEL 105

GENERAL

Sampling Frequency

128 samples per cycle; (50/60) Hz (16 samples/cycle 400 Hz)

Data Storage Rate

1 per second (200 ms also available on PEL 105)

Demand Period Storage Rate

User selectable (1, 2, 3, 4, 5, 6, 10, 12, 15, 20, 30 and 60 min)

Recorded Parameters (Single- and Poly-Phase)

V, I, W, VA, var, PF, Tan, Wh, VAh, varh, THD (V and I), Individual harmonics (from 1 through 50 per phase); Crest Factor (CF), Cos f / DPF

Event Log

Tracks and records status changes and error messages along with recorded data

Front Panel Indicator LEDs

Bluetooth active, recording in progress, phase connection reversal, overload, battery charging and SD card status

Storage Capacity

8 GB SD card included / SD cards up to 32 GB formatted FAT32 are supported

INPUTS

Voltage

PEL 102/103: 3 input channels / PEL 105: 4 input channels via 4 mm safety banana jacks

Current

PEL 102/103: 3 input channels PEL 105: 4 input channels via custom 4 pin jacks that accept AEMC® Instruments probes and sensors

ELECTRICAL

VOLTAGE MEASUREMENT

RANGE

RESOLUTION*

ACCURACY*

(50/60) Hz

(42.5 to 69) Hz

­

± 0.1 Hz

Single-Phase RMS Voltages

(10 to 1000) Vrms

0.1 V

± 0.2 % Reading ± 0.2 V

Phase-to-Phase RMS Voltages

(17 to 1700) Vrms

(0.1 to 1) V

± 0.2 % Reading ± 0.4 V

400 Hz

(340 to 460) Hz

­

Single-Phase RMS Voltages

(10 to 600) Vrms

0.1 V

± 1 % Reading ± 1 V

Phase-to-Phase RMS Voltages

(17 to 1200) Vrms

(0.1 to 1) V

± 1 % Reading ± 1 V

DC

(100 to 1000) V

0.1 V

± 1 % Reading ± 3 V (typical)

PT Ratios

Programmable from (50 to 650,000) V

­

(0.01 to 0.1) V

CURRENT MEASUREMENT

A193 A*** (PEL 102/103)

196 A*** (PEL 105)

­

Nominal range for current probes

supplied with kit. (See chart on

200 mA to 10,000 A

­

Pages 32 and 33 for other probes)

CT Ratios

Programmable from 1:1 to 25,000:1 (probe dependent)

POWER MEASUREMENTS

RANGE

RESOLUTION*

ACCURACY*

Active Power (P)*

(-2 to 2) GW

0.001 W

± 0.5 % Reading ± 0.005 % Pnom

Reactive Power (Q)*

(-2 to 2) Gvar

0.001 var

± 1 % Reading ± 0.01 % Qnom

Apparent Power (S)*

(0 to 2) GVA

0.001 VA

± 0.5 % Reading ± 0.005 % Snom

Power Factor Tangent Ç (active/reactive power ratio)

-1 to 1 -3.2 to 3.2

0.001 0.001

± 0.05 ± 0.02

ENERGY MEASUREMENTS

RANGE

RESOLUTION*

ACCURACY*

Active Energy (EP)

4 EWh

1 Wh

± 0.5 % Reading

Reactive Energy (EQ) Apparent Energy (ES) THD Individual Harmonics External Supply Power From Phase Measurement Back-Up Power Supply/Charge Time Battery Life MECHANICAL Communication
Dimension/Weight
Case Display Type for Models PEL 103 & 105 ENVIRONMENTAL / SAFETY Operating Temperature/Relative Humidity Storage Temperature
Safety Rating/CE Rating
Ingress Protection

4 Evarh

1 varh

± 2 % Reading

4 EVAh

1 VAh

± 0.5 % Reading

± 655 %

1 to 50 displayed in percentage; 1 to 7 at 400 Hz

110/250 V (10 %) @ (50/60) Hz; 400 Hz

PEL 102/103: Requires optional 600 V Power Adapter / PEL 105: Internal up to 1000 VAC

Rechargeable 8.4 V NiMH battery pack / Approximately 5 hr

30 min minimum, 60 min typical

USB 2.0, Ethernet (RJ45), Wireless Bluetooth Class 1 **/ Wi-Fi (PEL 105) PEL 102/103: (10.08 x 4.92 x 1.46) in (256 x 125 x 37) mm / 2.20 lb (1 kg)
PEL (105: 9.8 x 7.8 x 2.6) in (249 x 198 x 66) mm / 8.8 lb (4 kg) Double insulated, rubber over-molded, polycarbonate UL94 V1 rated
(2.63 x 2.16) in (67 x 55) mm, four line, monochrome, backlit LCD with adjustable brightness and contrast

PEL 102/103/105: (32 to 108.5) °F (0 to 42.5) °C / up to 85 % RH (-4 to 122) °F (-20 to 50) °C with batteries; (-4 to 158) °F (-20 to 70) °C without batteries PEL 102/103: Complies with IEC 61010-1, and IEC 61010-2-030 for 1000 V CAT III / 600 V CAT IV
1000 V CAT IV (PEL 105), Pollution Degree 2 / Yes PEL 102/103: IP54 non operating / PEL 105: IP67 with cover closed

Consult factory for NIST Calibration prices

* Maximum value is current probe dependent.

** Computers with Class II Bluetooth will restrict range to 40 ft; Computers without Bluetooth will require a Class I or Class II Bluetooth radio adapter.

*** Maximum current reduced by a factor of 2 for 400 Hz fundamental frequency.

Vol. 23 Rev.00 02/2023

Technical Assistance (800) 343-1391
© Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved.

www.aemc.com 119

POWER QUALITY / ENERGY ANALYZERS, METERS & LOGGERS
OPTIONAL ACCESSORIES

SENSOR TYPE
MiniFlex® MA193-BK* & MiniFlex® MA194-BK*

CURRENT RANGE

ACCURACY (TYPICAL)

TYPICAL
OENRÿROART
(50/60) HZ

MAX CONDUCTOR
SIZE

USED WITH MODEL

CATALOG NUMBER

2.75 in (70 mm) (10 in sensor)

2140.48 (10 in sensor)

100 mA to 12,000 AAC(1)

10, 14 or 24 in sensor MR193-BK

SR193-BK

Battery operated

(1 to 1000) AAC (1 to 1300) ADC
(1 to 1200) AAC

AmpFlex® 193-BK*

100 mA to 12,000 AAC(1)

24 in or 36 in sensor MiniFlex® 196-BK*

± 1 %

3.94 in (100 mm) (14 in sensor)

PEL 102 PEL 103 PEL 105

2140.50 (14 in sensor)

0 °

8333

8336

8436

7.64 in (194 mm) (24 in sensor)

8345

2140.80 (24 in sensor)

± 2.5 % ± 0.3 %

-0.80 ° 0.2 °

1.6 in (41 mm)
2.05 in (52 mm)

PEL 102 PEL 103 PEL 105
8333 8336 8436 8345
PEL 102 PEL 103 PEL 105
8333 8336 8436 8345

2140.28 2140.33

± 1 %

7.64 in (194 mm) (24 in sensor)

PEL 102 PEL 103

2140.34 (24 in sensor)

PEL 105

0 °

8333

8336

8436

11.46 in (291 mm) (36 in sensor)

8345

2140.35 (36 in sensor)

3.9 in (99 mm) (14 in sensor)

2140.79 (14 in sensor)

Waterproof, IP67 14 in or 24 in sensor

100 mA to 12,000 AAC(1)

± 1 %

0 °

PEL 105 8436

7.64 in (194 mm) (24 in sensor)

2140.75 (24 in sensor)

*Maximum current reduced by a factor of 2 for 400 Hz fundamental frequency. All current sensors can be used with Models PEL 105, 8435 and 8436. However, only the MA196-14-BK and 196A-24-BK flexible sensors are waterproof. (1) Current range may be limited by sensor size or meter type. Consult factory for NIST Calibration prices

120 www.aemc.com

Technical Assistance (800) 343-1391
© Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved.

Vol. 23 Rev.00 02/2023

POWER QUALITY/ENERGY ANALYZERS, METERS & LOGGERS
OPTIONAL ACCESSORIES

SENSOR TYPE MN93-BK
MN193-BK

CURRENT RANGE (0.5 to 240) AAC

ACCURACY (TYPICAL)

TYPICAL
OENRRÿOART
(50/60) HZ

MAX CONDUCTOR
SIZE

USED WITH MODEL

LIMITED RANGE IF USED WITH MODEL

CATALOG NUMBER

PEL 102

PEL 103

± 1 %

0.8 °

0.78 in (20 mm)

PEL 105 8333

N/A

2140.32

8336

8345

100 A

200 mA to 120 AAC

± 1 %

0.75 °

PEL 102 PEL 103

0.78 in (20 mm)

PEL 105 8333

N/A

2140.36

8336

5 A

5 mA to 6 AAC ± 1 %

1.7 °

8345

SL261

100 A (5 to 100) AAC/DC ± 4 %

± 0.5 °

PEL 102 PEL 103

0.46 in (12 mm)

PEL 105 8333

N/A

1201.51

10 A

50 mA to 10 AAC/DC

± 3 %

± 1 °

8336 8345

All current sensors can be used with models PEL 105 and 8436. However, only the MA196-14-BK and 196 A-24-BK flexible sensors are waterproof. Consult factory for NIST Calibration prices

ACCESSORIES/REPLACEMENTS
CATALOG #1201.51 AC/DC Current Probe Model SL261 (BNC)
CATALOG #2140.40 BNC Adapter for AC/DC Current Probe Model SL261

ACCESSORIES/REPLACEMENTS
CATALOG #2140.34 AmpFlex® Sensor 24 in Model 193-24-BK
CATALOG #2140.35 AmpFlex® Sensor 36 in Model 193-36-BK

CATALOG #2140.77 Phase Power Adapter for use with PowerPad Models 8333 & 8336

CATALOG #2140.36 AC Current Probe Model MN193-BK

CATALOG #2137.98 600 V CAT III Power Adapter for use with Models PEL 102 and PEL 103 only
CATALOG #2140.28 AC/DC Current Probe Model MR193-BK
CATALOG #2140.32 AC Current Probe Model MN93-BK
CATALOG #2140.33 AC Current Probe Model SR193-BK

CATALOG #2140.48 MiniFlex® Sensor 10 in Model MA193-10-BK
CATALOG #2140.50 MiniFlex® Sensor 14 in Model MA193-14-BK
CATALOG #2140.80 MiniFlex® Sensor 24 in Model MA194-24-BK
CATALOG #2140.75 AmpFlex® Sensor 24 in (Waterproof - IP67) Model 196A-24-BK
CATALOG #2140.79 MiniFlex® Sensor 14 in Waterproof - IP67) Model MA196-14-BK

Vol. 23 Rev.00 02/2023

Technical Assistance (800) 343-1391
© Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved.

www.aemc.com 121

POWER QUALITY / ENERGY ANALYZERS, METERS & LOGGERS
SELECTION CHART

AEMC MODEL NUMBER

AEMC CATALOG NUMBER

INPUT TERMINALS

RMS

RMS

PEAK

PEAK

VOLTAGE VOLTAGE VOLTAGE VOLTAGE

CHANNELS MAX

MAX

MAX

MAX

PHASE-TO- PHASE-TO- PHASE-TO- PHASE-TO-

NEUTRAL PHASE NEUTRAL PHASE

8333 2136.10 4 V/3 I

3 V/4 I 1000 Vrms 2000 Vrms 1414 Vpk 2828 Vpk

DC VOLTAGE
MAX
1200 VDC

AC CURRENT MAX (PROBE DEPENDENT)

DC CURRENT MAX (PROBE DEPENDENT)

RATIOS VOLT

RATIOS AMPERE

10,000 AAC 5000 ADC Yes

Yes

8336 2136.30 5 V/4 I

4 V/4 I 1000 Vrms 2000 Vrms 1414 Vpk 2828 Vpk 1200 VDC 10,000 AAC 5000 ADC Yes

Yes

8345 2136.35 5 V/4 I

4 V/4 I 1000 Vrms 2000 Vrms 1414 Vpk 2828 Vpk 1200 VDC 10,000 AAC 5000 ADC Yes

Yes

8436 2136.43 5 V/4 I

4 V/4 I 1000 Vrms 2000 Vrms 1414 Vpk 2828 Vpk 1200 VDC 10,000 AAC 5000 ADC Yes

Yes

PEL 52 2137.71 2 V/2 I

2 V/2 I 660 Vrms 1200 Vrms

­

­

­

3600 AAC

­

No

Yes

PEL 102 2137.51 4 V/3 I

3 V/3 I 1000 Vrms 1700 Vrms 1414 Vpk 2400 Vpk 1000 VDC 10,000 AAC 5000 ADC Yes

Yes

PEL 103 2137.52 4 V/3 I

3 V/3 I 1000 Vrms 1700 Vrms 1414 Vpk 2400 Vpk 1000 VDC 10,000 AAC 5000 ADC Yes

Yes

PEL 105 2137.57 5 V/4 I

4 V/4 I

1000 Vrms

1414 Vpk 2400 Vpk 1000 VDC 10,000 AAC 5000 ADC Yes

Yes

AEMC AEMC MODEL CATALOG NUMBER NUMBER

DISTRIBUTION SYSTEMS

PHASE ROTATION

WAVEFORM TRANSIENT MODE MODE

TRUE INRUSH MODE/TYPE/ DURATION

ALARM MODE

HARMONIC SNAPSHOT MODE/
MODE INTERHARMONIC MODE

TYPE LCD

POWER SOURCE

8333

2136.10

1 P-2 W, 2 P-3 W, 3 P-3 W, 3 P-4 W

Yes

1 P-2 W, 1 P-3 W,

8336

2136.30

2 P-2 W, 2 P-3 W, 2 P-4 W, 3 P-3 W,

Yes

3 P-4 W, 3 P-5 W

1 P-2 W, 1 P-3 W,

8345

2136.35

2 P-2 W, 2 P-3 W, 2 P-4 W, 3 P-3 W,

Yes

3 P-4 W, 3 P-5 W

1 P-2 W, 1 P-3 W,

8436

2136.43

2 P-2 W, 2 P-3 W, 2 P-4 W, 3 P-3 W,

Yes

3 P-4 W, 3 P-5 W

1 P-2 W,

PEL 52 2137.71

2 P-3 W,

Yes

1 P-3 W

PEL 102 2137.51

Yes

1 P-2 W, 1 P-3 W, 3

PEL 103 2137.52

P-3 W D2, 3 P-3 W O2, 3 P-3 W Y2, 3

Yes

P-3 W D3, 3 P-3 W

O3, 3 P-3 W Y, 3P-3

W DB, 3 P-4 W Y, 3

P-4 W YB, 3 P-4 W PEL 105 2137.57 Y2 1/2, 3 P-4 W D, 3 Yes

P-4 WOD, DC-2 W

DC-3 W, DC-4 W

No

10 types/ up to
2 active/ 4662
recorded

Yes (12)

Yes / No

TFT - 5.7 in External diagonal adapter with 320 x 240 internal NiMH resolution battery pack

Yes (RMS+PEAK
& RMS) up to 1 & 10 min

40 types/ up to
7 active/ 16,362 recorded

Yes (50)

Yes / No

TFT - 5.7 in External diagonal adapter with 320 x 240 internal NiMH resolution battery pack

Yes (RMS+PEAK
& RMS) up to 10 &
30 min

40 types/ Yes DC to 63rd order; 20,000 (no limit < 3 % Udin / w/ email with SD 0 to 62nd order; notificatoins card) < 0.5 % Udin

7 in color LCD touch
screen: 800 x 480
(WVGA)

External adapter with Li-ion battery
pack

Yes (RMS+PEAK
& RMS) up to 1 & 10 min

40 types/ up to
7 active/ 16,362 recorded

Yes (50)

Yes / No

TFT - 5.7 in Line Power diagonal with internal 320 x 240 NiMH battery resolution pack

Power phase

No

No / No

Monochrome input with LCD internal NiMH

battery pack

No

Yes / No

None Line Power

with internal

No

Yes / No

Monochrome LCD

NiMH battery pack

Power phase

input or

No

Yes / No

Monochrome LCD

external adapter with internal

NiMH battery

pack

122 www.aemc.com

Technical Assistance (800) 343-1391
© Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved.

Vol. 23 Rev.00 02/2023

TEST(ALNADB)MINESATSRUURMEMENETNST

DATA ANALYSIS AND REPORTING SOFTWARE

SEE PAGE 133 FOR MORE INFO ON DATAVIEW® SOFTWARE

CONFIGURE INSTALLATION TESTERS
MODELS CA 6116N & CA 6117
Print reports of all test results / Set instrument parameters and measurement settings on your PC and transfer to the instrument / Retrieve data from the instrument's memory

SEE WEBSITE FOR PRICING AND AVAILABILITY: WWW.AEMC.COM

TEST AND MEASUREMENT (LAB) INSTRUMENTS
DC POWER SUPPLIES & DECADE BOX

MODEL AX503

Rugged and accurate power supplies can handle a direct short without causing damage

SPECIFICATIONS

MODEL Number of Outputs VOLTAGE Output 1 & 2 Output 3 (No display) Display Resolution Basic Accuracy Residual Ripple LINE REGULATION ± 10 % Line Voltage LOAD REGULATION
(0 to 2.5) A (0 to 5) A
CURRENT Output 1 & 2 Output 3 Resolution Basic Accuracy Limit Indicator Short-Circuit Protection Overheating Protection OUTPUT COUPLING
Tracking
Series Mode Parallel Mode Power Supply

AX503 3
(0 to 30) VDC (2.7 to 5.5) VDC
100 mV ± 0.5 % of Reading ± 1 ct
± 1 mVrms
± 0.03 % of Reading ± 2 mV
± 0.02 % of Reading ± 5 mV ± 0.2 % Reading ± 10 mV
(0 to 2.5) A 5 A max (no adjustment)
10 mA ± 0.5 % of Reading ± 1 ct LED, Outputs 1, 2 and 3 Electronic current limitation with voltage shutdown
Thermal protection
Output 1: Leader/Output 2: Follower Proportional Follower Tracking
(0 to 100 % of Leader) (0 to 60) VDC/(0 to 2.5) A (0 to 30) VDC/(0 to 5) A 110 V, (50/60) Hz (220 V optional)

Consult factory for NIST Calibration prices

FEATURES
· Dual (0 to 30) VDC / (0 to 2.5) A outputs
· 5.5 V / 5 A output
· Series and parallel operation permit (0 to 60) V or (0 to 5) A output
· Low noise (< 1 mV ripple) and stable linear technology for clean output
· High efficiency toroidal transformers: no fan and low electromagnetic emissions
· Active protection against overloads, short circuits and overheating
· Unique variable tracking mode for leader/follower operation: follower or leader track proportionally to the original setting
· Simultaneous display of voltage and current
· Highly visible green (V) and red (A) LED displays
ACCESSORIES/REPLACEMENTS
CATALOG #2117.78 Lead set includes (2) color-coded (red/black) safety leads, (2) color-coded (red/black) alligator clips (1) ground lead (green), and (2) color-coded (red/black) grip probes

MODEL BR07 Bench top decade box that stands up to the task!

SPECIFICATIONS

TYPES
Accuracy Max Current mADC

MULTIPLYING FACTOR IN «

1

10 100 1 k 10 k 100 k

1 % ± 10 m

700 mA 200 mA 70 mA 20 mA 7 mA 1 mA

1 M 0.1 mA

Consult factory for NIST Calibration prices For more product specifications visit: www.aemc.com/products/decade-boxes/

ACCESSORIES/REPLACEMENTS
CATALOG #2131.35 Replacement, 6 ft safety lead, 4 mm female to female for Decade Boxes

BR07
FEATURES
RESISTANCE DECADE BOX BR07 · Resistance box: 7 decades covering
a range from 1  to 11.11111 M · 11-position switches · Output via 4 mm safety banana jacks · Accuracy: 1 % ± 10 m on all ranges

CATALOG NO. DESCRIPTION

2130.07 2131.25

DC Power Supply Model AX503 (Triple outputs, two (0 to 2.5) A; (0 to 30) VDC; (2.7 to 5.5) VDC) Resistance Decade Box Model BR07 (x1 , x10 , x100 , x1 k, x10 k, x100 k, x1 M, 1 %)

124 www.aemc.com

Technical Assistance (800) 343-1391
© Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved.

Vol. 23 Rev.00 02/2023

TEST AND MEASUREMENT (LAB) INSTRUMENTS
MULTIFUNCTION INSTALLATION TESTERS
MODELS CA 6116N & CA 6117 Safety for your electrical installations and high performance with these unique instruments

SPECIFICATIONS

MODELS CONTINUITY/RESISTANCE

CA 6116N

CA 6117

I Rated/Range/Resolution
Range/Resolution/Accuracy INSULATION Rated Voltage Range/Resolution/Accuracy Short-Circuit Current

I > 200 mA / 39.99  / 0.01  / ± (1.5 % of measurement + 2 cts); 12 mA / 39.99  & 399.9  / 0.01 & 0.1  / ± (1.5 % of measurement + 5 cts) with beep 4 k / 1  / ± (1.5 % of measurement + 5 cts); (40 to 400 k) / (10 to 100 ) / ± (1.5 % of measurement + 2 cts)
50 VDC,100 VDC, 250 VDC, 500 VDC, 1000 VDC 0.01 M to 2 G / 10 k to 1 M / ± (5 % of measurement + 3 cts)
 3 mA

GROUND RESISTANCE

3-Point Range/Resolution/Accuracy

(0.50 to 40)  / 0.01  / ± (2 % of measurement + 10 cts); 40  to 15 k / (0.1 to 1)  / ± (2 % of measurement + 2 cts); (15 to 40) k / 10  / ± (10 % of measurement + 2 cts)

Ufk

Complies with SEV 3569

1-Point Selective Range/Resolution/Accuracy

(0.20 to 39.99)  to (40 to 399.9)  / (0.01 to 0.1)  / ± (10 % of measurement + 10 cts) (ISel via clamp)

LOOP IMPEDANCE (Zs (L-PE) & Zi (L-N or L-L)) / 1-POINT LIVE GROUND

Live Ground Installation Voltage/Frequency

(90 to 500) V / (15.8 to 17.5) Hz and (45 to 65) Hz

HIGH-CURRENT MODE WITH TRIP Zs (L-PE) & Zi (L-N or L-L)

Range/Resolution/Accuracy

Max. test current: 7.5 A (0.050) (0.100 to 0.5)  / 0.001  / ± (10 % of measurement + 20 cts); (0.5 to 3.999)  / 0.001  / ± (5 % of measurement + 20 cts);
(3.999 to 39.99)  / 0.01  / ± (5 % of measurement + 2 cts); (39.99 to 399.99)  / 0.1  / ± (5 % of measurement + 2 cts)

No TRIP Mode (Zs (L-PE) only)

Test current: (6, 9, or 12) mA (as required) (0.20 to 0.99)  / 0.01  / ± (15 % of measurement + 10 cts) (1.00 to 1.99)  / 0.01  / ± (15 % of measurement + 3 cts) (2.00 to 39.99)  / 0.01  / ± (10 % of measurement + 3 cts)
(40.00 to 399.9)  / 0.1  / ± (5 % of measurement + 2 cts) (400 to 3999)  / 1  / ± (5 % of measurement + 2 cts)

Calculation of Ik Short-Circuit Current PFC (Zs), I Sc PSCC (Zi)

Fault current and short-circuit current: 0.1 A to 20 kA

Integrated Fuse Table Voltage Drop V % (Zi) Others AC & A-TYPE RCDs Installation Voltage/Frequency

­

Yes

­

(-40 to 40) %

Measurement of the resistive and inductive components of the Zs and Zi impedances

(90 to 500) V / (15.8 to 17.5) Hz and (45 to 65) Hz

In
No TRIP Test Ramp Mode TRIP TIME MEASUREMENT
Range/Resolution/Accuracy
B-TYPE RCDs Installation Voltage/Frequency In: Ramp/Pulse 2 x In Pulse 4 x In Test in Ramp Mode

(10/30/100/300/500/650/1000) mA (90 to 280) V or variable ­ (10/30/100/300/500) mA (280 to 550) V or variable Ramp and pulse test
at ½ In ­ Duration: 1000 or 2000 ms 0.2 to 0.5 x In (Uf) / 0.3 x In to 1.06 x In in increments of 3.3 % x In

(0.50 to 40)  / 0.01  / ± (2 % of measurement + 10 cts); 40  to 15 k / (0.1 to 1)  / ± (2 % of measurement + 2 cts);
(15 to 40) k / 10  / ± (10 % of measurement + 2 cts)

­

(90 to 275) V / (15.8 to 17.5) Hz and (45 to 65) Hz

­

(10/30/100/300/500) mA and (10/30/100) mA with pulse 4 In Duration: 150 ms with 4 x In or 300 ms with 2 x In

­

0.2 x In to 2.2 x In

TRIP Test: 2 x In & 4 x In

IN  200 mA: 2.2 x 2 x In

­

IN > 200 mA: 1.1 x 2 x In

IN  100 mA: 2.2 x 4 x In

Vol. 23 Rev.00 02/2023

Technical Assistance (800) 343-1391
© Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved.

Specifications continued on next page. www.aemc.com 125

TEST AND MEASUREMENT (LAB)
INSTRUMENTS
MULTIFUNCTION INSTALLATION TESTERS

SPECIFICATIONS - CONTINUED
MODELS OTHER MEASUREMENTS Current by Clamps C177 Current by Clamp MN77 Voltage Frequency Phase Rotation Active Power
Harmonics GENERAL SPECIFICATIONS Display
Storage/Communication Power Supply (rechargeable battery) Battery Life Dimensions/Weight SAFETY Safety Rating Ingress Protection EMC *If a voltage is connected to the instrument

CA 6116N

CA 6117

5.0 mA to 199.9 A (1 mA*) 5.0 mA to 19.99 A (0 to 550) VAC/DC and (15.8 to 500) Hz
(10 to 500) Hz (20 to 500) VAC (0 to 110) kW single-phase ­ (0 to 330) kW three-phase Simultaneous display of voltage and current waveforms Voltage and current/up to 50th order / THD-F / THD-R

Large 5.7 in backlit graphic color, LCD screen, 320 x 240 points
Via USB for data transfer and report creation Li-ion 10.8 V rated 5.8 A·h Up to 30 h
(11.02 x 7.48 x 5.04) in (280 x 190 x 128) mm / 4.85 lb (2.2 kg)

IEC 61010 -1/600 V CAT III & 300 V CAT IV/IEC 61557 IP53 / IK04 IEC 61326-1

FEATURES
· Testing according to the international standards: IEC 60364-6, NF C 15-100, VDE 100, XP C 16-600, etc.
· Simple, reliable connection supported by contextual help for each function, including all the connection diagrams
· Suitable for all neutral systems (TT, TN, IT)
· Type-B RCD testing available (Model CA 6117)
· Li-ion battery for a longer battery life
· Measurements: voltage, current via clamp, power, waveforms and harmonics
· Measurement of voltage drop for correct sizing of conductor diameters
· Loop measurement with 1 m resolution
· 3-level storage
· Includes DataView® analysis software for programming, downloading, storing and report generation of test data
· Integrated fuse table for quick reading of the results on the instrument

IP 53
PRODUCT INCLUDES
Carrying bag, US power cord and charger, Li-ion battery pack, USB A/B cable, set of (3) 3-prong color-coded (red, blue, green) safety voltage leads, set of (3) color-coded (red, blue, green) test probes, set of (3) color-coded (red/blue/green) alligator clips, set of (2) color-coded (red/black) safety leads 4 mm straight plug, 3-prong US measurement cord, remote test probe, wrist strap, hands-free strap, multilingual safety card, and a USB drive with DataView® software and user manual.

SPECIAL ORDERS ONLY

CATALOG NO.
2138.06 2138.07 2138.10 2138.11

DESCRIPTION
Multi-Function Installation Tester Model CA 6116N (US) (includes DataView® Software) - SPECIAL ORDER ONLY Multi-Function Installation Tester Model CA 6117 (US) (includes DataView® Software) - SPECIAL ORDER ONLY Multi-Function Installation Tester Model CA 6116N Kit (US) (includes C177A, DataView® Software) - SPECIAL ORDER ONLY Multi-Function Installation Tester Model CA 6117 Kit (US) (includes C177A, DataView® Software) - SPECIAL ORDER ONLY

126 www.aemc.com

Technical Assistance (800) 343-1391
© Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved.

Vol. 23 Rev.00 02/2023

THERMAL IMAGING CAMERAS
SEE WEBSITE FOR PRICING AND AVAILABILITY: WWW.AEMC.COM

THERMAL IMAGING CAMERAS
INFRARED CAMERAS

MODEL 1954

Versatile tool for performing infrared thermography

Indispensable means for ensuring safety in industrial application

SPECIFICATIONS

MODEL

1954

IR DETECTOR

Type

UFPA microbolometer

Spectral Range

8~14 m

Resolution

(120 x 160) pixels

IMAGING PERFORMANCE

NETD

80 mK @ 86 °F (30 °C)

Frequency

9 Hz

Field of View

28 ° x 38 °

IFOV (spatial resolution)

4.1 mrad

Minimal Focal Distance

0.98 ft (0.3 m), fixed focus

FOCUSING

Adjustment

Fixed

VISUAL IMAGE

Resolution

(480 x 640) pixels

Minimal Focal Distance

2 in (5 cm), fixed focus

PRESENTATION OF IMAGES

Images Displayed LCD Screen

Infrared image, visual image with automatic parallax compensation. Merging of both images is possible with included PC software 2.8 in (7.1 cm)

Display Colors

Pseudo-colors, multiple palettes

LASER POINTER

Type

Class 2 645-655 nm power: 1 mW

FUNCTIONS

Image Freezing Data Storage MEASUREMENT

Animated or fixed image 2 GB Micro SD card included (approx. 4,000 images)
Replaceable with up to 32 GB SD card

Temperature Range

(-4 to 482) °F (-20° to 250) °C

Accuracy

± 3.6 °F (± 2 °C) or ± 2 % of reading

ANALYSIS FUNCTIONS

Measurement Tools Adjustment

Manual cursor, automatic detection, min/max/avg on adjustable area, temperature profile, and isotherm
Automatic or manual adjustment palette min-max

Parameter Settings

Emissivity, environmental temperature, distance, and relative humidity

Isotherm Display

Color display of a temperature range adjustable by the user

Voice Recordings

via Bluetooth headset (included)

ENVIRONMENTAL

Operating Temperature

(-4 to 122) °F (-15 to 50) °C; 95 % RH

Storage Temperature

(-40 to 158) °F (-40 to 70) °C

Humidity

(10 to 95) %

Drop Resistance

6 ft (2 m) on all sides

Impact Resistance

25 G

Vibration Resistance

2 G

GENERAL

Start Up

Less than 10 seconds

Power Supply

(4) AA NiMH rechargeable batteries with external charger included

Laser/Output/Wavelength

Class 2 / < 1 mW / 645-655 nm

Tripod Mounting

1/4 in insert on camera (tripod not included)

Battery Life Dimensions/Weight
Bluetooth Communication

9 h typical (7 h minimum) (8.86 x 4.92 x 3.27) in (225 x 125 x 83) mm / 24.7 oz (700 g) with rechargeable batteries 407, 607 clamps, DMMs MTX 3292B-BT and MTX 3293B-BT and logger
models 1110, 1200 and 1800 Series

Safety Rating

EN 61326-1: 2006, EN 61010-1 Ed.02

Consult factory for NIST Calibration prices

THERMO RESOLUTION (120 X 160) Pixels
IP 54
FEATURES
· Focus-free with 28 ° x 38 ° field of view · Automatic brightness control · Exceptionally long battery life · Quick startup in less than 10 seconds · User configurable emissivity table · User configurable cursor and
trigger functions · User selectable color palette · Captures thermal and real
image simultaneously · Verbally record your comments
directly to the image using included Bluetooth headset · Wirelessly connect to AEMC® Instruments Clamp-on Meters, Multimeters, and Environmental Meters and record their measurements simultaneously with your thermograms · Comprehensive CAmReport® software included that offers all the necessary functions for reliable analysis of the measurement results and report generation
ACCESSORIES/REPLACEMENTS
CATALOG #2121.60
Carrying case with foam insert
CATALOG #2126.49
USB cable Type A to 5-pin Mini-B

128 www.aemc.com

Technical Assistance (800) 343-1391
© Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved.

Vol. 23 Rev.00 02/2023

THERMAL IMAGING CAMERAS
INFRARED CAMERAS

DISPLAY & MENU CONTENTS

STATUS BAR

Battery Trigger status function Emissivity

Date & time of Fixed image: ü current image Dynamic: ü

MENU Selectable using navigation keys

SD card presence

CA Bluetooth

logo

active

FUNCTION KEYS Linked to selected menu choice or camera image

CONTEXTUAL HELP
This display area updates based on the menu item selected

A comprehensive set of easy access menus are available on screen. You can use the function and navigation keys to easily configure the camera for your specific needs. Trigger functions can be programmed, color palettes can be selected, cursor tools can be configured as well as environmental conditions including ambient temperature and humidity, distance and emissivity.

SELECTABLE CURSOR TOOLS

User programmable cursors provide a comprehensive set of options for evaluating thermal profiles

NONE

MIN/MAX

POINT

No cursor display, temperature evaluation is determined by color palette only. ISOTHERM

Automatically displays the cold and hot spot values at the Min and Max cursor positions.
PROFILE

Displays the value at the cursor. Cursor is movable using the navigation keys.
SQUARE

Displays points that fall in the same temperature range in the same color. User picks green, red or brown as the
display color and defines the range and tolerance.

Displays the temperature profile of a horizontal line defined by the cursor. Cursor can be moved along the line to get an individual temperature.

Displays the Min/Max and mean values within the box. Box size and location is user adjustable.

Vol. 23 Rev.00 02/2023

Technical Assistance (800) 343-1391
© Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved.

www.aemc.com 129

THERMAL IMAGING CAMERAS
INFRARED CAMERAS

CAmReport® SOFTWARE FOR ANALYZING THERMOGRAMS
This comprehensive software offers all the necessary functions for effective analysis of the measurement results and report generation

Report creation is automatic, using one of three available templates. Reports can be exported in Word or PDF format making it simple to print and/or archive them.

FEATURES
· Transfer measurements from your camera to the software by USB cable, or transportable SD card
· Drag-and-drop measurement images from the storage directory to the analysis window in the software
· Includes thermal and real images automatically
· Superimpose thermal images over real images for better visual analytical results
· Locate Min/Max and mean temperatures of the image or an area of the image
· User selectable color palette from seven different types
· Summary table automatically displays environmental parameters and statistical results of the measurement
· Include dictated audio comments into the report with the Bluetooth headset
· Includes multiple analytical tools for assessing thermal images
· Manually enter measurement analysis findings, site characteristics and operator information to your report
· Add graphics such as logos to your reports
· Correct the measurement results using built-in or user configured emissivity tables
· Include multiple measurements in any report
· Save reports as a Word or PDF document
PRODUCT INCLUDES
Carrying case, USB cable, external battery charger, (4) NiMH rechargeable batteries, micro SD card with adapter, Bluetooth headset, printed quick start guide, and a USB drive with CAmReport software, and user and software manuals.

Typical analysis tab screen

CATALOG NO. DESCRIPTION

2121.41

Thermal Imaging IR Camera Model 1954 (Resolution 120 x 160)

130 www.aemc.com

Technical Assistance (800) 343-1391
© Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved.

Vol. 23 Rev.00 02/2023

TRANSFORMER RATIOMETERS

DATA ANALYSIS AND REPORTING SOFTWARE

SEE PAGE 133 FOR MORE INFO ON DATAVIEW® SOFTWARE

CONFIGURE TRANSFORMER RATIOMETERS
DTR® MODEL 8510
Display and analyze data on your PC computer / Configure functions and parameters from your PC / Customize views, templates, and reports to your exact needs / Create and store a complete library of configurations that can be uploaded to the instrument / Print reports using standard or custom templates

SEE WEBSITE FOR PRICING AND AVAILABILITY: WWW.AEMC.COM

TRANSFORMER RATIOMETERS

DTR® MODEL 8510
Designed for on-site testing of power, potential and current transformers

SPECIFICATIONS

MODEL VT/PT Ratio Range CT Ratio Range Accuracy*
Excitation Signal
Excitation Current Display Excitation Frequency Measurement Method Display
Languages Supported Communication Data Storage Power Supply
External Charger Battery Life
Charging Time SAFETY Safety Rating / IP

DTR® 8510 Auto-Ranging 0.8000:1 to 8000:1 Auto-Ranging 0.8000 to 1000.0 Ratio 0.8000 to 9.9999 ± 0.2 % of Reading Ratio 10.000 to 999.99 ± 0.1 % of Reading Ratio 1000.0 to 4999.9 ± 0.2 % of Reading Ratio 5000.0 to 8000.0 ± 0.25 % of Reading VT/PT Mode: 32 Vrms maximum CT Mode: (0 to 1) A, (0.1 to 4.5) Vrms
Range: (0 to 1000) mA; Accuracy: ± 2 % of Reading ± 2 mA
70 Hz
In accordance with ANSI/IEEE C57.12.90TM-2006 LCD 16 character, 2 line, large format, LED backlight, day/night visible English, Spanish, French, Italian,
German, Portuguese Optically isolated USB 2.0 Stores up to 10,000 complete measurements (2) rechargeable 12 V NiMH batteries
(included) (90/240) V, (50/60) Hz (smart charger)
Up to 10 h continuous operation; May not be used while recharging;
Low battery LED/LCD indication < 4 h
EN 61010-1; 50 V CAT IV / IP54 (cover closed)

Reference Condition: *(23 ± 5) °C, (50 to 70) % RH, full battery charge, no external fields or noise.

Consult factory for NIST Calibration prices

PRODUCT INCLUDES
Soft carrying case, set of (2) 15 ft black leads, set of (2) color-coded (red/black) alligator clips, 10 ft USB cable, external battery charger (90-264 VAC, (50/60) Hz), NiMH batteries (installed), 115 V power cord, and USB drive with DataView® software and user manual.

IP 54 cover closed
FEATURES
· Measures power transformers, VT/PTs and current transformer CT turns ratios
· Displays turn ratio, excitation current, winding polarity and % deviation from the nameplate values
· Universal voltage (90/240) V supply, (50/60) Hz via external smart/fast battery charger; completely charge in less than 4 hours
· Two internal NiMH batteries provide up to 10 hours of continuous operation · Tests performed by exciting the primary and reading the secondary ­
provides safer conditions for the operator · Display warns of incorrect lead connection, reverse polarity, open and
short circuits · Easy connection and test setup; no calibration or balancing required · Large dual display with adjustable contrast ensures clearer visibility
in any lighting environment day or night · Low battery indicator · Stores up to 10,000 test results in internal memory · USB port facilitates configuring the instrument and downloading
test results · Includes DataView® analysis software for programming, downloading,
storing and report generation of test data

ACCESSORIES/REPLACEMENTS
CATALOG #2136.76 Set of (2) leads, 30 ft for DTR®
CATALOG #2136.77 Set of (2) leads, 15 ft for DTR® (Replacement)

CATALOG NO. DESCRIPTION

2136.50

Digital Transformer Ratiometer DTR® Model 8510 (110 V/220 V)

132 www.aemc.com

Technical Assistance (800) 343-1391
© Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved.

Vol. 23 Rev.00 02/2023

DATAVRIEEWP® ORDTAITNAGASNOAFLTYWSIASR&E

· LOCAL & REMOTE COMMUNICATIONS · CONFIGURE · DOWNLOAD AND STORE RECORDED DATA

· ANALYZE · ANNOTATE · CREATE STANDARD AND CUSTOM REPORTS

The DataView® software platform designed and developed by AEMC® Instruments, is a comprehensive and powerful analytical and reporting tool used in conjunction with our broad line of electrical test instruments. Our goal in developing this unique software package was to make available one application compatible with any of our instruments that requires software, making it easier for the end-user who operates different AEMC® Instruments products. In this way, learning and using the software does not change with the instrument in use.

We also implemented it in such a way that it will be backward compatible with older instruments even as new versions are released and new innovative instruments are supported. Plus, we supply it free with each instrument purchased, and upgrades when released are always free.

INSTRUMENTS EQUIPPED WITH DATAVIEW® SOFTWARE:

CLAMP-ON METERS
MODELS 407, 607
DATA LOGGERS
MODELS L261, L562, DL913, DL914 & L452

ENVIRONMENTAL INSTRUMENTS
MODELS 1110, 1246, 1821, 1822, 1823 & 1510
GROUND TESTERS
MODELS 6417, 6471 & 6472

MEGOHMMETERS
MODELS 1060, 5060, 5070, 6526, 6534, 6550, 6555, CA 6116 & CA 6117
MICRO-OHMMETERS
MODELS 6240, 6255 & 6292

POWER QUALITY / ENERGY ANALYZERS, METERS & LOGGERS
MODELS PEL 52, 102, 103, 105, 8333, 8336, 8345 & 8436
TRANSFORMER RATIOMETER
MODEL 8510

SEE WEBSITE FOR PRICING AND AVAILABILITY: WWW.AEMC.COM

DDAATTAAVAIENWA®LDYASTIAS A&NRAELYPSOISRTAINNDGRSEOPFOTRWTIANRGESOFTWARE

DataView® automatically recognizes a device when it is connected to a PC and starts the corresponding menu providing direct access to a device's recorded data. An end-user can access predefined reports with full safety compliance to current standards for quick editing. They can also define and save their own configured reports, views, etc. as well as the instrument according to their needs saving significant time in the field.

STANDARD DATAVIEW® FUNCTIONS
For All Applicable Instruments:
· Capture, display and analyze real-time data on your PC
· Easily configure all functions and parameters specific to each instrument from your PC
· Create and store a complete library of configurations that can be uploaded to a device as needed
· Create custom views, templates, and reports to your exact needs
· Zoom in and out and pan through sections of graphs to analyze the data
· View measurements in real-time (model specific), download, display and analyze recorded and stored data
· Display waveforms, trend graphs, harmonic spectrums, text summaries, transients, event logs and stored alarms
· Print all test result reports using our standard report templates or your custom templates
· Free updates available from the help menu on your instrument or on our website: www.aemc.com/resources

ADDITIONAL DATAVIEW® FUNCTIONS
For Meghommeters: · Select test voltage and run tests from your computer
with a simple click and execute process · Retrieve data from the instruments' memory for:
­ Over 1500 insulation resistance measurements ­ Over 4000 resistance measurements · Display DAR and PI ratios · Plot graphs of manual and timed tests · Include your analysis comments section with the report · Store a library of setups for different applications · Certification of results through report generation

AUTOMATIC REPORT GENERATION Easily create reports from an instrument with the click of a button.

Reports can be displayed on a PC and printed. Each report includes all test results in a tabular and graphic format, as well as operator and test site information. Comments typed by the operator will also be included.

134 www.aemc.com

Technical Assistance (800) 343-1391
© Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved.

Vol. 23 Rev.00 02/2023

INSTRUMENTS SUPPORTED BY DATAVIEW®
· Power Quality/Energy, Analyzers, Meters & Loggers
· Ground Resistance Testers · Insulation Resistance Testers · Low Resistance Micro-Ohmmeters · Transformer Ratiometers · Data Loggers · Environmental Loggers · Clamp-on Meters · Installation Testers

COMMUNICATION
· USB · Wi-Fi · Bluetooth · Ethernet
ô
INSTRUMENT CONFIGURATION
øø · User defined
· Load from stored configurations · Save new configurations

LOCAL & REMOTE REAL-TIME MONITORING
· Single Instrument
ù · Multiple Instruments
DATA ANALYSIS
· Zoom in and out to identify important data points
· Annotation and labeling of data points
· Tracking Min, Max, Peak and Average values
· Object linking and embedding

DATA RETRIEVAL
þ AND STORAGE
· Direct connect to the instrument · Transfer from SD card · Over the internet · From local area network

135 www.aemc.com

Technical Assistance (800) 343-1391
© Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved.

REPORT GENERATION
· Predefined report templates · Customizable report templates · Data Export to other formats
(Excel, .csv) · Creation of PDF files
Vol. 23 Rev.00 01/2023

DDAATTAAVAIENWA®LDYASTIAS A&NRAELYPSOISRTAINNDGRSEOPFOTRWTIANRGESOFTWARE

TYPICAL DATAVIEW® DIGITAL AND GRAPHIC DISPLAYS
CLEAR AND SIMPLE SETUP OF ALL FUNCTIONS AND SETTINGS FROM ONE TABBED DIALOG BOX

DATA LOGGERS

GROUND TESTERS

POWER QUALITY / ENERGY ANALYZERS, METERS & LOGGERS

ENVIRONMENTAL

MEGOHMMETERS

Display report waveforms by phase, parameter or total

Recorded data displays recorded measurements vs. time as well as min, max, and average
measurements for the recording. A movable cursor lets you see values at the cursor location.

All stored test results presented on screen

Clear and straightforward set up of parameters
A typical report will include a plot of the data as well as a listing of the measurements

Display harmonics in a text table from harmonic 0 (DC) through the 50th

Run test and display text and graphical results from one dialog box. Model 5070 also displays
step voltage.

Test result status box

displays complete test

A report cover sheet provides information about results in real-time

the operator, test site and a comment section to type in the test results and recommendations.

Insulation resistance with temperature compensation

Step voltage during the test run

Display real-time phasor diagrams with phase angles

136 www.aemc.com

Technical Assistance (800) 343-1391
© Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved.

Vol. 23 Rev.00 02/2023

DATA ANALYSIS & REPORTING SOFTWARE

TYPICAL DATAVIEW® FUNCTIONAL DISPLAYS
CLEAR AND SIMPLE SETUP OF ALL FUNCTIONS AND SETTINGS FROM ONE TABBED DIALOG BOX

DATA LOGGERS

MEGOHMMETERS

ENVIRONMENTAL

Tabbed dialog boxes allow for clear and easy setup of all functions of the Megohmmeters, including
setup for variable voltage and alarm set points, as well as step voltage tests and temperature compensation

Typical status screen showing the current state of the instrument

GROUND TESTERS

Variable Voltage selections from (40 to 5100) V and can also be programmed along with alarm set points
(model dependent)

The recording configuration screen provides the ability to assign a name & location to the recording session, set the retrieval rate, and schedule when recordings
will start and stop. It also displays memory usage
Other screens allow for the selection of measurement units, alarm set points, and other user selectable parameters.

Configure and control ground resistance tests from your computer through the use of clear and easy-to-use tabbed dialog boxes. All Ground Tester functions can be configured
and tests can be initiated with graphical illustration of the proper connections

Model 5070 includes Step Function which allows programming of three different ramp test profiles, each containing up to five voltage steps between (40 to 5100) V and time per step of up to 10 hours

POWER QUALITY / ENERGY ANALYZERS, METERS & LOGGERS :
Configure alarms, inrush and transient capture, network configuration, recording storage rate and
length and more.

Vol. 23 Rev.00 02/2023

Technical Assistance (800) 343-1391
© Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved.

www.aemc.com 137

TRAINING SEMINARS

AEMC® INSTRUMENTS TECHNICAL TRAINING WEBINARS & SEMINARS

­ Offered throughout the USA ­ Ground Resistance Testing, Insulation Resistance Testing and Power Quality ­ Public and private courses are available ­ On-site or online training courses

UNDERSTANDING GROUND UNDERSTANDING INSULATION

RESISTANCE TESTING

RESISTANCE TESTING

UNDERSTANDING POWER QUALITY

For field engineers, technicians, utility engineers, supervisors, electricians and inspectors interested in testing and grounding systems.
KEY TOPICS INCLUDE
· Soil resistivity · Bond resistance · Ground resistance
- 3 and 4 Point Fall-of-Potential testing - Clamp-on testing - Alternate test methods · NEC 250 requirements, NFPA 780 Lightning Protection Standards and IEEE Green Book standards discussed in depth · Continuity testing in common ground systems required by multiple standards · Create plots and reports

For technicians, supervisors, electricians, plant maintenance personnel and inspectors interested in insulation resistance testing on motors, cables, transformers and other electrical equipment.
KEY TOPICS INCLUDE
· Insulation test theory · Insulation testing on motors, cables,
and transformers · Spot testing · Timed testing · DAR (Dielectric Absorption Ratio),
PI (Polarization Index), DD (Dielectric Discharge) · Temperature correction · Report generation

For engineers, technicians, supervisors, electricians, plant maintenance personnel and inspectors interested in monitoring, recording and analyzing power quality and energy monitoring.
KEY TOPICS INCLUDE
· Symptoms and problems associated with poor Power Quality
· Measuring common voltage disturbances and transients
· Harmonic Analysis - causes and how to measure harmonics
· Bonding issues and their relationship with Power Quality
· Power Factor - measuring and understanding its importance to power quality.
· IEEE Emerald Book standards discussed in depth

FOR THE SCHEDULE OF UPCOMING TRAINING SEMINARS CONTACT

[email protected], VISIT OUR WEBSITE AT WWW.AEMC.COM

138 www.aemc.com

OR CALL (800) 343-1391 Technical Assistance (800) 343-1391

Vol. 23 Rev.00 02/2023

© Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All Rights Reserved.

TECHNICAL SALES AND ASSISTANCE
If you experience technical problems, or require assistance with the proper use or application of any AEMC® instrument, please call our technical hotline at (800) 343-1391 ext. 351. Technical assistance in Spanish is available at ext. 544.
15 Faraday Drive · Dover, NH 03820 USA Tel: (800) 343-1391 · (603) 749-6434 · Fax: (603) 742-2346 [email protected] · www.aemc.com
REPAIR AND CALIBRATION
To guarantee your instrument complies with the factory specifications, we recommend that your AEMC® Instruments purchased product be submitted to our factory service center at one year intervals for recalibration, or as required by other standards.
For instrument repairs and/or calibrations, please call our factory, toll-free, at (800) 945-2362 ext. 360.
Chauvin Arnoux®, Inc. d.b.a. AEMC® Instruments 15 Faraday Drive · Dover, NH 03820 USA Tel: (800) 945-2362 ext. 360 · (603) 749-6434 · Fax: (603) 742-2346 [email protected] · www.aemc.com Costs for repair, normal recalibration, and calibration traceable to NIST are available. NIST calibration pricing is listed within each product ordering chart on our website. All customers must call for an authorization number (CSA#) before returning any instrument.
WARRANTY
All AEMC® Instruments products carry a 2-year warranty (unless specified) against defects of material and workmanship which develop under normal and proper use within one to three years (product dependent) of original date of purchase when inspection proves the fault to be one of manufacturing. Detailed warranty coverage is located on our website. Products can be registered online at: www.aemc.com/support/product-registration.cfm Specifications and prices are subject to change without notice.
CORPORATE AND MANUFACTURING
Chauvin Arnoux®, Inc. d.b.a. AEMC® Instruments 15 Faraday Drive · Dover, NH 03820 USA Tel: (603) 749-6434 · Fax: (603) 742-2346 Order entry: Tel: (800) 945-2362 ext. 361 · Fax: (603) 749-9153 [email protected] · www.aemc.com Exports order entry: Tel: +1 (603) 749-6434 ext. 520 · Fax: +1 (603) 742-2346 [email protected] · www.aemc.com
ONLINE STORE
The AEMC® Instruments online store offers the opportunity to purchase replacement parts such as fuses, test leads and other accessory items for your test instruments. The online store also offers refurbished and discontinued items at a reduced price. Product specials are also offered online so visit our online store regularly at: www.aemc.com/store
FIND MORE AT: WWW.AEMC.COM

NEW PRODUCTS

AC DATA LOGGERS
MODELS DL913 & DL914 3 AND 4 CHANNEL AC DATA LOGGERS

DL913

DL914

PAGE 38

POWERPAD® IV MODEL 8345 CLASS A POWER/ENERGY QUALITY ANALYZER, METER AND DATA LOGGER

A POWERP D IV Class

MODEL PEL 52 POWER/ENERGY QUALITY ANALYZER METER AND DATA LOGGER
Your authorized AEMC® Instruments distributor is:

PAGES 108-109
PAGES 114-115

Chauvin Arnoux®, Inc. d.b.a. AEMC® Instruments 15 Faraday Dr. · Dover, NH 03820-4352 · USA (603) 749-6434 · (800) 343-1391 · Fax (603) 742-2346 · [email protected]
Export Department: +1 (603) 749-6434 Ext. 520 · Fax +1 (603) 742-2346 · [email protected]

950.CAT-MASTER-VOL23


GPL Ghostscript 10.00.0 Adobe InDesign 18.1 (Windows)